WorldWideScience

Sample records for isocratic elution utilizing

  1. Description of the Retention and Peak Profile for Chromolith Columns in Isocratic and Gradient Elution Using Mobile Phase Composition and Flow Rate as Factors

    Directory of Open Access Journals (Sweden)

    Elsa Cabo-Calvet

    2014-11-01

    Full Text Available The effect of the modifier concentration and flow rate on the chromatographic performance of a second generation Chromolith® RP-18e column, under isocratic and gradient elution with acetonitrile-water mixtures, was examined using four sulphonamides as probe compounds. The acetonitrile concentration was varied between 5 and 55% (v/v, and the flow rate between 0.1 and 5.0 mL/min, keeping the other factors constant. The changes in both retention and peak profile were modelled, and used to build simple plots, where the logarithm of the retention factor was represented against the modifier concentration (in gradient elution, against the initial modifier concentration, and the half-widths or widths against the retention time (in gradient elution, against the time at the column outlet. A particular plot was needed for describing the retention of each sulphonamide, but due to the similar interaction kinetics, a unique plot described the changes in the half-widths for all four sulphonamides. The changes in retention with the flow showed that allegedly in the second generation Chromolith, the column deformation observed for the first generation Chromolith, with the applied pressure at increasing flow, is decreased.

  2. Strategic Combination of Isocratic and Gradient Elution for Simultaneous Separation of Polar Compounds in Traditional Chinese Medicines by HPLC

    Directory of Open Access Journals (Sweden)

    Mei-Tuo Zhang

    2018-01-01

    Full Text Available A simple high-performance liquid chromatography (HPLC method for the simultaneous separation of the highly polar and weakly polar components of traditional Chinese medicines was developed via a strategic combination of isocratic and gradient elution methods. Liu-Shen-Wan and Liu-Wei-Di-Huang-Wan were used as representative examples of traditional Chinese medicines. This is the first time that 6 components of varying degrees of polarity in Liu-Shen-Wan had been successfully resolved in a single chromatographic run using an ultraviolet-visible detector with a fixed wavelength of 296 nm. In contrast to conventional gradient separation methods, this novel method offered a viable route for separation of the highly and weakly polar fractions simultaneously, thus greatly reducing the time and cost of analysis. This method therefore provides a more efficient way to determine the polar components present in traditional Chinese medicines. It would find potential application in drug screening, drug authentication, and product quality control.

  3. Application of Snyder-Dolan classification scheme to the selection of "orthogonal" columns for fast screening of illicit drugs and impurity profiling of pharmaceuticals--I. Isocratic elution.

    Science.gov (United States)

    Fan, Wenzhe; Zhang, Yu; Carr, Peter W; Rutan, Sarah C; Dumarey, Melanie; Schellinger, Adam P; Pritts, Wayne

    2009-09-18

    Fourteen judiciously selected reversed phase columns were tested with 18 cationic drug solutes under the isocratic elution conditions advised in the Snyder-Dolan (S-D) hydrophobic subtraction method of column classification. The standard errors (S.E.) of the least squares regressions of logk' vs. logk'(REF) were obtained for a given column against a reference column and used to compare and classify columns based on their selectivity. The results are consistent with those obtained with a study of the 16 test solutes recommended by Snyder and Dolan. To the extent these drugs are representative, these results show that the S-D classification scheme is also generally applicable to pharmaceuticals under isocratic conditions. That is, those columns judged to be similar based on the 16 S-D solutes were similar based on the 18 drugs; furthermore those columns judged to have significantly different selectivities based on the 16 S-D probes appeared to be quite different for the drugs as well. Given that the S-D method has been used to classify more than 400 different types of reversed phases the extension to cationic drugs is a significant finding.

  4. Application of Snyder-Dolan Classification Scheme to the Selection of “Orthogonal” Columns for Fast Screening for Illicit Drugs and Impurity Profiling of Pharmaceuticals - I. Isocratic Elution

    Science.gov (United States)

    Fan, Wenzhe; Zhang, Yu; Carr, Peter W.; Rutan, Sarah C.; Dumarey, Melanie; Schellinger, Adam P.; Pritts, Wayne

    2011-01-01

    Fourteen judiciously selected reversed-phase columns were tested with 18 cationic drug solutes under the isocratic elution conditions advised in the Snyder-Dolan (S-D) hydrophobic subtraction method of column classification. The standard errors (S.E.) of the least squares regressions of log k′ vs. log k′REF were obtained for a given column against a reference column and used to compare and classify columns based on their selectivity. The results are consistent with those obtained with a study of the 16 test solutes recommended by Snyder and Dolan. To the extent that these drugs are representative these results show that the S-D classification scheme is also generally applicable to pharmaceuticals under isocratic conditions. That is, those columns judged to be similar based on the S-D 16 solutes were similar based on the 18 drugs; furthermore those columns judged to have significantly different selectivities based on the 16 S-D probes appeared to be quite different for the drugs as well. Given that the S-D method has been used to classify more than 400 different types of reversed phases the extension to cationic drugs is a significant finding. PMID:19698948

  5. Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions.

    Science.gov (United States)

    Vanderlinden, Kim; Broeckhoven, Ken; Vanderheyden, Yoachim; Desmet, Gert

    2016-04-15

    We report on the results of an experimental and theoretical study of the effect of the extra-column band broadening (ECBB) on the performance of narrow-bore columns filled with the smallest particles that are currently commercially available. Emphasis is on the difference between the effect of ECBB under gradient and isocratic conditions, as well as on the ability to model and predict the ECBB effects using well-established band broadening expressions available from the theory of chromatography. The fine details and assumptions that need to be taken into account when using these expressions are discussed. The experiments showed that, the steeper the gradient, the more pronounced the extra-column band broadening losses become. Whereas the pre-column band broadening can in both isocratic and gradient elution be avoided by playing on the possibilities to focus the analytes on top of the column (e.g. by using the POISe injection method when running isocratic separations), the post-column extra-column band broadening is inescapable in both cases. Inducing extra-column band broadening by changing the inner diameter of the post-column tubing from 65 to 250 μm, we found that all peaks in the chromatogram are strongly affected (around a factor of 1.9 increase in relative peak width) when running steep gradients, while usually only the first eluting peak was affected in the isocratic mode or when running shallow gradients (factor 1.6-1.8 increase in relative peak width for the first eluting analyte). Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Elution strategies for reversed-phase high-performance liquid chromatography analysis of sucrose alkanoate regioisomers with charged aerosol detection

    DEFF Research Database (Denmark)

    Lie, Aleksander; Pedersen, Lars Haastrup

    2013-01-01

    A broad range of elution strategies for RP-HPLC analysis of sucrose alkanoate regioisomers with CAD was systematically evaluated. The HPLC analyses were investigated using design-of-experiments methodology and analysed by analysis of variance (ANOVA) and regression modelling. Isocratic elutions, ...

  7. Isocratic and gradient impedance plot analysis and comparison of some recently introduced large size core-shell and fully porous particles.

    Science.gov (United States)

    Vanderheyden, Yoachim; Cabooter, Deirdre; Desmet, Gert; Broeckhoven, Ken

    2013-10-18

    The intrinsic kinetic performance of three recently commercialized large size (≥4μm) core-shell particles packed in columns with different lengths has been measured and compared with that of standard fully porous particles of similar and smaller size (5 and 3.5μm, respectively). The kinetic performance is compared in both absolute (plot of t0 versus the plate count N or the peak capacity np for isocratic and gradient elution, respectively) and dimensionless units. The latter is realized by switching to so-called impedance plots, a format which has been previously introduced (as a plot of t0/N(2) or E0 versus Nopt/N) and has in the present study been extended from isocratic to gradient elution (where the impedance plot corresponds to a plot of t0/np(4) versus np,opt(2)/np(2)). Both the isocratic and gradient impedance plot yielded a very similar picture: the clustered impedance plot curves divide into two distinct groups, one for the core-shell particles (lowest values, i.e. best performance) and one for the fully porous particles (highest values), confirming the clear intrinsic kinetic advantage of core-shell particles. If used around their optimal flow rate, the core-shell particles displayed a minimal separation impedance that is about 40% lower than the fully porous particles. Even larger gains in separation speed can be achieved in the C-term regime. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Development of a fast isocratic LC-MS/MS method for the high-throughput analysis of pyrrolizidine alkaloids in Australian honey.

    Science.gov (United States)

    Griffin, Caroline T; Mitrovic, Simon M; Danaher, Martin; Furey, Ambrose

    2015-01-01

    Honey samples originating from Australia were purchased and analysed for targeted pyrrolizidine alkaloids (PAs) using a new and rapid isocratic LC-MS/MS method. This isocratic method was developed from, and is comparable with, a gradient elution method and resulted in no loss of sensitivity or reduction in chromatographic peak shape. Isocratic elution allows for significantly shorter run times (6 min), eliminates the requirement for column equilibration periods and, thus, has the advantage of facilitating a high-throughput analysis which is particularly important for regulatory testing laboratories. In excess of two hundred injections are possible, with this new isocratic methodology, within a 24-h period which is more than 50% improvement on all previously published methodologies. Good linear calibrations were obtained for all 10 PAs and four PA N-oxides (PANOs) in spiked honey samples (3.57-357.14 µg l(-1); R(2) ≥ 0.9987). Acceptable inter-day repeatability was achieved for the target analytes in honey with % RSD values (n = 4) less than 7.4%. Limits of detection (LOD) and limits of quantitation (LOQ) were achieved with spiked PAs and PANOs samples; giving an average LOD of 1.6 µg kg(-1) and LOQ of 5.4 µg kg(-1). This method was successfully applied to Australian and New Zealand honey samples sourced from supermarkets in Australia. Analysis showed that 41 of the 59 honey samples were contaminated by PAs with the mean total sum of PAs being 153 µg kg(-1). Echimidine and lycopsamine were predominant and found in 76% and 88%, respectively, of the positive samples. The average daily exposure, based on the results presented in this study, were 0.051 µg kg(-1) bw day(-1) for adults and 0.204 µg kg(-1) bw day(-1) for children. These results are a cause for concern when compared with the proposed European Food Safety Authority (EFSA), Committee on Toxicity (COT) and Bundesinstitut für Risikobewertung (BfR - Federal Institute of Risk Assessment Germany) maximum

  9. Analysis of conjugated linoleic acid-enriched triacylglycerol mixtures by isocratic silver-ion high-performance liquid chromatography.

    Science.gov (United States)

    Adlof, R O; Menzel, A; Dorovska-Taran, V

    2002-04-12

    Silver-ion HPLC (Ag-HPLC) was applied to the fractionation of a triacylglycerol (TAG) sample enriched (>80%) with conjugated linoleic acid (CLA). After conversion of the TAGs to fatty acid methyl esters using sodium methoxide in methanol, Ag-HPLC (dual-column; isocratic solvent system of 0.1% acetonitrile in hexane; UV detection at 233 nm) was used to determine the CLA isomer distribution (50:50 mixture of 9c 11t- and 10t,12c-18:2). Three or four Ag-HPLC columns connected in series (0.6-1.0% acetonitrile in hexane as solvent; UV detection at 206 nm) were used to analyze the sample in TAG form. Elution times for CLA-enriched TAGs averaged 30 min or less. Isocratic solvent conditions were used to eliminate the solvent equilibration times (often 30 min or more) required between sample injections when solvent programming is used. The ratio of TAGs containing three vs. only two CLA molecules was found to be approximately 3 to 1. Ag-HPLC has thus been shown to be a useful method for rapidly analyzing not only CLA isomers as esters, but also in the TAG form.

  10. Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment

    Science.gov (United States)

    Groskreutz, Stephen R.; Weber, Stephen G.

    2016-01-01

    In this work we characterize the development of a method to enhance temperature-assisted on-column solute focusing (TASF) called two-stage TASF. A new instrument was built to implement two-stage TASF consisting of a linear array of three independent, electronically controlled Peltier devices (thermoelectric coolers, TECs). Samples are loaded onto the chromatographic column with the first two TECs, TEC A and TEC B, cold. In the two-stage TASF approach TECs A and B are cooled during injection. TEC A is heated following sample loading. At some time following TEC A’s temperature rise, TEC B’s temperature is increased from the focusing temperature to a temperature matching that of TEC A. Injection bands are focused twice on-column, first on the initial TEC, e.g. single-stage TASF, then refocused on the second, cold TEC. Our goal is to understand the two-stage TASF approach in detail. We have developed a simple yet powerful digital simulation procedure to model the effect of changing temperature in the two focusing zones on retention, band shape and band spreading. The simulation can predict experimental chromatograms resulting from spatial and temporal temperature programs in combination with isocratic and solvent gradient elution. To assess the two-stage TASF method and the accuracy of the simulation well characterized solutes are needed. Thus, retention factors were measured at six temperatures (25–75 °C) at each of twelve mobile phases compositions (0.05–0.60 acetonitrile/water) for homologs of n-alkyl hydroxylbenzoate esters and n-alkyl p-hydroxyphenones. Simulations accurately reflect experimental results in showing that the two-stage approach improves separation quality. For example, two-stage TASF increased sensitivity for a low retention solute by a factor of 2.2 relative to single-stage TASF and 8.8 relative to isothermal conditions using isocratic elution. Gradient elution results for two-stage TASF were more encouraging. Application of two-stage TASF

  11. Multiple dual mode counter-current chromatography with variable duration of alternating phase elution steps.

    Science.gov (United States)

    Kostanyan, Artak E; Erastov, Andrey A; Shishilov, Oleg N

    2014-06-20

    The multiple dual mode (MDM) counter-current chromatography separation processes consist of a succession of two isocratic counter-current steps and are characterized by the shuttle (forward and back) transport of the sample in chromatographic columns. In this paper, the improved MDM method based on variable duration of alternating phase elution steps has been developed and validated. The MDM separation processes with variable duration of phase elution steps are analyzed. Basing on the cell model, analytical solutions are developed for impulse and non-impulse sample loading at the beginning of the column. Using the analytical solutions, a calculation program is presented to facilitate the simulation of MDM with variable duration of phase elution steps, which can be used to select optimal process conditions for the separation of a given feed mixture. Two options of the MDM separation are analyzed: 1 - with one-step solute elution: the separation is conducted so, that the sample is transferred forward and back with upper and lower phases inside the column until the desired separation of the components is reached, and then each individual component elutes entirely within one step; 2 - with multi-step solute elution, when the fractions of individual components are collected in over several steps. It is demonstrated that proper selection of the duration of individual cycles (phase flow times) can greatly increase the separation efficiency of CCC columns. Experiments were carried out using model mixtures of compounds from the GUESSmix with solvent systems hexane/ethyl acetate/methanol/water. The experimental results are compared to the predictions of the theory. A good agreement between theory and experiment has been demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Simulation of elution profiles in liquid chromatography - II: Investigation of injection volume overload under gradient elution conditions applied to second dimension separations in two-dimensional liquid chromatography.

    Science.gov (United States)

    Stoll, Dwight R; Sajulga, Ray W; Voigt, Bryan N; Larson, Eli J; Jeong, Lena N; Rutan, Sarah C

    2017-11-10

    An important research direction in the continued development of two-dimensional liquid chromatography (2D-LC) is to improve the detection sensitivity of the method. This is especially important in applications where injection of large volumes of effluent from the first dimension ( 1 D) column into the second dimension ( 2 D) column leads to severe 2 D peak broadening and peak shape distortion. For example, this is common when coupling two reversed-phase columns and the organic solvent content of the 1 D mobile phase overwhelms the 2 D column with each injection of 1 D effluent, leading to low resolution in the second dimension. In a previous study we validated a simulation approach based on the Craig distribution model and adapted from the work of Czok and Guiochon [1] that enabled accurate simulation of simple isocratic and gradient separations with very small injection volumes, and isocratic separations with mismatched injection and mobile phase solvents [2]. In the present study we have extended this simulation approach to simulate separations relevant to 2D-LC. Specifically, we have focused on simulating 2 D separations where gradient elution conditions are used, there is mismatch between the sample solvent and the starting point in the gradient elution program, injection volumes approach or even exceed the dead volume of the 2 D column, and the extent of sample loop filling is varied. To validate this simulation we have compared results from simulations and experiments for 101 different conditions, including variation in injection volume (0.4-80μL), loop filling level (25-100%), and degree of mismatch between sample organic solvent and the starting point in the gradient elution program (-20 to +20% ACN). We find that that the simulation is accurate enough (median errors in retention time and peak width of -1.0 and -4.9%, without corrections for extra-column dispersion) to be useful in guiding optimization of 2D-LC separations. However, this requires that real

  13. Simultaneous separation of water- and fat-soluble vitamins in isocratic pressure-assisted capillary electrochromatography using a methacrylate-based monolithic column.

    Science.gov (United States)

    Yamada, Hiroki; Kitagawa, Shinya; Ohtani, Hajime

    2013-06-01

    A method of simultaneous separation of water- and fat-soluble vitamins using pressure-assisted CEC with a methacrylate-based capillary monolithic column was developed. In the proposed method, water-soluble vitamins were mainly separated electrophoretically, while fat soluble-ones were separated chromatographically by the interaction with a methacrylate-based monolith. A mixture of six water-soluble and four fat-soluble vitamins was separated simultaneously within 20 min with an isocratic elution using 1 M formic acid (pH 1.9)/acetonitrile (30:70, v/v) containing 10 mM ammonium formate as a mobile phase. When the method was applied to a commercial multivitamin tablet and a spiked one, the vitamins were successfully analyzed, and no influence of the matrix contained in the tablet was observed. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. An isocratic HPLC method for the simultaneous determination of cholesterol, cardiolipin, and DOPC in lyophilized lipids and liposomal formulations.

    Science.gov (United States)

    Simonzadeh, Ninus

    2009-04-01

    Phospholipids, such as 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC), and 1,1',2,2'-tetramyristoyl cardiolipin, along with cholesterol, form liposomes in aqueous media and have been investigated at NeoPharm (Lake Bluff, IL) as drug-delivery systems. To accurately assess the effectiveness of various formulations involving the use of aforementioned phospholipids and cholesterol, their quantitative determination is essential. An isocratic high-performance liquid chromatographic method for the simultaneous determination of cholesterol, cardiolipin, and DOPC in various pharmaceutical formulations containing the active drug substance has consequently been developed and is presented here. The current method utilizes an ASTEC-diol analytical column and is shown to be stability-indicating and free from interference from any of the formulation excipients, such as sucrose, sodium chloride, and sodium lactate. The analytes are detected using an evaporative light scattering detector (Alltech or Polymer Laboratories). The quantitation of each lipid component is performed using non-linear regression analysis. The retention characteristics of the analytes are examined as a function of eluent composition (e.g., pH, salt content, organic to aqueous phase ratio) and column temperature. The method was validated and was found to be sensitive, specific, rugged, and cost-effective. The current method provides enhanced chromatographic separation for lipid components as well as degradation products as compared to similar methods reported in the literature. It is also inherently simpler than other similar methods reported in the literature that typically use complex gradient elution.

  15. Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study.

    Science.gov (United States)

    Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T

    2006-01-01

    To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Cost-utility analysis of audit based patient subgroups by means of a simple economic model. Tertiary care. 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost-utility ratio and threshold price premium. Four factors were identified for patients undergoing elective surgery (n = 1951) and two for non-elective surgery (n = 933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non-elective surgery group with 9.9% risk). Modelled cost-utility ratios were acceptable for only one group of high risk patients undergoing non-elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be 112 pound sterling (212 USD, 162 pound sterling) (sirolimus stents) or 89 pound sterling (167 USD, 130 pound sterling) (paclitaxel stents). At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially.

  16. Innovative Elution Processes for Recovering Uranium from Seawater

    International Nuclear Information System (INIS)

    Wai, Chien; Tian, Guoxin; Janke, Christopher

    2014-01-01

    Utilizing amidoxime-based polymer sorbents for extraction of uranium from seawater has attracted considerable interest in recent years. Uranium collected in the sorbent is recovered typically by elution with an acid. One drawback of acid elution is deterioration of the sorbent which is a significant factor that limits the economic competitiveness of the amidoxime-based sorbent systems for sequestering uranium from seawater. Developing innovative elution processes to improve efficiency and to minimize loss of sorbent capacity become essential in order to make this technology economically feasible for large-scale industrial applications. This project has evaluated several elution processes including acid elution, carbonate elution, and supercritical fluid elution for recovering uranium from amidoxime-based polymer sorbents. The elution efficiency, durability and sorbent regeneration for repeated uranium adsorption- desorption cycles in simulated seawater have been studied. Spectroscopic techniques are used to evaluate chemical nature of the sorbent before and after elution. A sodium carbonate-hydrogen peroxide elution process for effective removal of uranium from amidoxime-based sorbent is developed. The cause of this sodium carbonate and hydrogen peroxide synergistic leaching of uranium from amidoxime-based sorbent is attributed to the formation of an extremely stable uranyl peroxo-carbonato complex. The efficiency of uranium elution by the carbonate-hydrogen peroxide method is comparable to that of the hydrochloric acid elution but damage to the sorbent material is much less for the former. The carbonate- hydrogen peroxide elution also does not need any elaborate step to regenerate the sorbent as those required for hydrochloric acid leaching. Several CO2-soluble ligands have been tested for extraction of uranium from the sorbent in supercritical fluid carbon dioxide. A mixture of hexafluoroacetylacetone and tri-n-butylphosphate shows the best result but uranium

  17. Innovative Elution Processes for Recovering Uranium from Seawater

    Energy Technology Data Exchange (ETDEWEB)

    Wai, Chien [Univ. of Idaho, Moscow, ID (United States); Tian, Guoxin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Janke, Christopher [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-05-29

    Utilizing amidoxime-based polymer sorbents for extraction of uranium from seawater has attracted considerable interest in recent years. Uranium collected in the sorbent is recovered typically by elution with an acid. One drawback of acid elution is deterioration of the sorbent which is a significant factor that limits the economic competitiveness of the amidoxime-based sorbent systems for sequestering uranium from seawater. Developing innovative elution processes to improve efficiency and to minimize loss of sorbent capacity become essential in order to make this technology economically feasible for large-scale industrial applications. This project has evaluated several elution processes including acid elution, carbonate elution, and supercritical fluid elution for recovering uranium from amidoxime-based polymer sorbents. The elution efficiency, durability and sorbent regeneration for repeated uranium adsorption- desorption cycles in simulated seawater have been studied. Spectroscopic techniques are used to evaluate chemical nature of the sorbent before and after elution. A sodium carbonate-hydrogen peroxide elution process for effective removal of uranium from amidoxime-based sorbent is developed. The cause of this sodium carbonate and hydrogen peroxide synergistic leaching of uranium from amidoxime-based sorbent is attributed to the formation of an extremely stable uranyl peroxo-carbonato complex. The efficiency of uranium elution by the carbonate-hydrogen peroxide method is comparable to that of the hydrochloric acid elution but damage to the sorbent material is much less for the former. The carbonate- hydrogen peroxide elution also does not need any elaborate step to regenerate the sorbent as those required for hydrochloric acid leaching. Several CO2-soluble ligands have been tested for extraction of uranium from the sorbent in supercritical fluid carbon dioxide. A mixture of hexafluoroacetylacetone and tri-n-butylphosphate shows the best result but uranium

  18. Hydrogen sulfide production by sulfate-reducing bacteria utilizing additives eluted from plastic resins.

    Science.gov (United States)

    Tsuchida, Daisuke; Kajihara, Yusuke; Shimidzu, Nobuhiro; Hamamura, Kengo; Nagase, Makoto

    2011-06-01

    In the present study it was demonstrated that organic additives eluted from plastic resins could be utilized as substrates by sulfate-reducing bacteria. Two laboratory-scale experiments, a microcosm experiment and a leaching experiment, were conducted using polyvinyl chloride (PVC) as a model plastic resin. In the former experiment, the conversion of sulfate to sulfide was evident in microcosms that received plasticized PVC as the sole carbon source, but not in those that received PVC homopolymer. Additionally, dissolved organic carbon accumulated only in microcosms that received plasticized PVC, indicating that the dissolved organic carbon originated from additives. In the leaching experiment, phenol and bisphenol A were found in the leached solutions. These results suggest that the disposal of waste plastics in inert waste landfills may result in the production of H(2)S.

  19. LC-H-1 NMR used for determination of the elution order of S-naproxen glucuronide isomers in two isocratic reversed-phase LC-systems

    DEFF Research Database (Denmark)

    Mortensen, R. W.; Corcoran, O.; Cornett, Claus

    2001-01-01

    . In both systems the elution order for the 2-, 3- and 4-O-acyl isomers corresponded with previously published results for 2-, 3-, and 4-fluorobenzoic acid glucuronide isomers determined by reversed phase HPLC-H-1 NMR [U.G. Sidelmann, S.H. Hansen, C. Gavaghan, A.W. Nicholls, H.A.J. Carless, J.C. Lindon, I...

  20. Development of an elution device for ViroCap virus filters.

    Science.gov (United States)

    Fagnant, Christine Susan; Toles, Matthew; Zhou, Nicolette Angela; Powell, Jacob; Adolphsen, John; Guan, Yifei; Ockerman, Byron; Shirai, Jeffry Hiroshi; Boyle, David S; Novosselov, Igor; Meschke, John Scott

    2017-10-19

    Environmental surveillance of waterborne pathogens is vital for monitoring the spread of diseases, and electropositive filters are frequently used for sampling wastewater and wastewater-impacted surface water. Viruses adsorbed to electropositive filters require elution prior to detection or quantification. Elution is typically facilitated by a peristaltic pump, although this requires a significant startup cost and does not include biosafety or cross-contamination considerations. These factors may pose a barrier for low-resource laboratories that aim to conduct environmental surveillance of viruses. The objective of this study was to develop a biologically enclosed, manually powered, low-cost device for effectively eluting from electropositive ViroCap™ virus filters. The elution device described here utilizes a non-electric bilge pump, instead of an electric peristaltic pump or a positive pressure vessel. The elution device also fully encloses liquids and aerosols that could contain biological organisms, thereby increasing biosafety. Moreover, all elution device components that are used in the biosafety cabinet are autoclavable, reducing cross-contamination potential. This device reduces costs of materials while maintaining convenience in terms of size and weight. With this new device, there is little sample volume loss due to device inefficiency, similar virus yields were demonstrated during seeded studies with poliovirus type 1, and the time to elute filters is similar to that required with the peristaltic pump. The efforts described here resulted in a novel, low-cost, manually powered elution device that can facilitate environmental surveillance of pathogens through effective virus recovery from ViroCap filters while maintaining the potential for adaptability to other cartridge filters.

  1. "Isocrater" impacts: Conditions and mantle dynamical responses for different impactor types

    Science.gov (United States)

    Ruedas, Thomas; Breuer, Doris

    2018-05-01

    Impactors of different types and sizes can produce a final crater of the same diameter on a planet under certain conditions. We derive the condition for such "isocrater impacts" from scaling laws, as well as relations that describe how the different impactors affect the interior of the target planet; these relations are also valid for impacts that are too small to affect the mantle. The analysis reveals that in a given isocrater impact, asteroidal impactors produce anomalies in the interior of smaller spatial extent than cometary or similar impactors. The differences in the interior could be useful for characterizing the projectile that formed a given crater on the basis of geophysical observations and potentially offer a possibility to help constrain the demographics of the ancient impactor population. A series of numerical models of basin-forming impacts on Mercury, Venus, the Moon, and Mars illustrates the dynamical effects of the different impactor types on different planets. It shows that the signature of large impacts may be preserved to the present in Mars, the Moon, and Mercury, where convection is less vigorous and much of the anomaly merges with the growing lid. On the other hand, their signature will long have been destroyed in Venus, whose vigorous convection and recurring lithospheric instabilities obliterate larger coherent anomalies.

  2. Zotarolimus-eluting vs. sirolimus-eluting coronary stents in patients with and without acute coronary syndromes

    DEFF Research Database (Denmark)

    Thim, Troels; Maeng, Michael; Kaltoft, Anne Kjer

    2012-01-01

    To compare clinical outcomes among patients with acute coronary syndrome treated with zotarolimus-eluting and sirolimus-eluting stents in the SORT OUT III trial.......To compare clinical outcomes among patients with acute coronary syndrome treated with zotarolimus-eluting and sirolimus-eluting stents in the SORT OUT III trial....

  3. Drug-eluting stents: from bench-top to clinical research

    NARCIS (Netherlands)

    Basalus, Mounir Welson Zakhary

    2013-01-01

    The development of drug-eluting stents (DES) has improved the invasive treatment of obstructive coronary artery disease by reducing both, restenosis rate and need for reinterventions. This success resulted in a widespread utilization of DES in clinical practice and entailed many clinical research

  4. Fractionating power and outlet stream polydispersity in asymmetrical flow field-flow fractionation. Part I: isocratic operation.

    Science.gov (United States)

    Williams, P Stephen

    2016-05-01

    Asymmetrical flow field-flow fractionation (As-FlFFF) has become the most commonly used of the field-flow fractionation techniques. However, because of the interdependence of the channel flow and the cross flow through the accumulation wall, it is the most difficult of the techniques to optimize, particularly for programmed cross flow operation. For the analysis of polydisperse samples, the optimization should ideally be guided by the predicted fractionating power. Many experimentalists, however, neglect fractionating power and rely on light scattering detection simply to confirm apparent selectivity across the breadth of the eluted peak. The size information returned by the light scattering software is assumed to dispense with any reliance on theory to predict retention, and any departure of theoretical predictions from experimental observations is therefore considered of no importance. Separation depends on efficiency as well as selectivity, however, and efficiency can be a strong function of retention. The fractionation of a polydisperse sample by field-flow fractionation never provides a perfectly separated series of monodisperse fractions at the channel outlet. The outlet stream has some residual polydispersity, and it will be shown in this manuscript that the residual polydispersity is inversely related to the fractionating power. Due to the strong dependence of light scattering intensity and its angular distribution on the size of the scattering species, the outlet polydispersity must be minimized if reliable size data are to be obtained from the light scattering detector signal. It is shown that light scattering detection should be used with careful control of fractionating power to obtain optimized analysis of polydisperse samples. Part I is concerned with isocratic operation of As-FlFFF, and part II with programmed operation.

  5. Evaluation of electrochemical ion exchange for cesium elution

    International Nuclear Information System (INIS)

    Bontha, J.D.; Kurath, D.E.; Surma, J.E.; Buehler, M.F.

    1996-04-01

    Electrochemical elution was investigated as an alternative method to acid elution for the desorption of cesium from loaded ion exchange resins. The approach was found to have several potential advantages over existing technologies, in particular, electrochemical elution eliminates the need for addition of chemicals to elute cesium from the ion exchange resin. Also, since, in the electrochemical elution process the eluting solution is not in direct contact with the ion exchange material, very small volumes of the eluting solution can be used in a complete recycle mode in order to minimize the total volume of the cesium elute. In addition, the cesium is eluted as an alkaline solution that does not require neutralization with caustic to meet the tank farm specifications. Other advantages include easy incorporation of the electrochemical elution process into the present cesium recovery schemes

  6. XIENCE V everolimus-eluting coronary stent system: a novel second generation drug-eluting stent

    NARCIS (Netherlands)

    Beijk, Marcel A. M.; Piek, Jon J.

    2007-01-01

    Drug-eluting stents (DES) have been shown to be safe and significantly reduce clinical events and angiographic restenosis in the percutaneous treatment of coronary artery disease. Currently, three DES have been approved in Europe and Northern America: the sirolimus-eluting stent (SES), the

  7. A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples

    Science.gov (United States)

    Amanolahi, Farjad; Mohammadi, Ali; Kazemi Oskuee, Reza; Nassirli, Hooriyeh; Malaekeh-Nikouei, Bizhan

    2017-01-01

    Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55, v/v, pH 3.5), C18 column (150 mm×4.6 mm×5 µm particle size) and a flow rate of 1 ml/min in ambient condition and total retention time of 17 min. The volume of injection was set at 20 µl and detection was recorded at 425 nm. The robustness of the method was examined by changing the mobile phase composition, mobile phase pH, and flow rate. Results: The method was validated with respect to precision, accuracy and linearity in a concentration range of 2-100 µg/ml. The limit of detection (LOD) and limit of quantification (LOQ) were 0.25 and 0.5 µg/ml, respectively. The percentage of recovery was 98.9 to 100.5 with relative standard deviation (RSD) < 0.638%. Conclusion: The method was found to be simple, sensitive and rapid for determination of curcumin in pharmaceutical samples and had enough sensitivity to detect degradation product of curcumin produced under photolysis and hydrolysis stress condition. PMID:29062806

  8. Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease

    DEFF Research Database (Denmark)

    Raungaard, Bent; Christiansen, Evald H; Bøtker, Hans Erik

    2017-01-01

    artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion......OBJECTIVES: The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients. BACKGROUND: Biodegradable-polymer biolimus-eluting stents are superior to first......-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking. METHODS: The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary...

  9. Novel HPLC Analysis of Hydrocortisone in Conventional and Controlled-Release Pharmaceutical Preparations

    OpenAIRE

    Adi-Dako, Ofosua; Oppong Bekoe, Samuel; Ofori-Kwakye, Kwabena; Appiah, Enoch; Peprah, Paul

    2017-01-01

    An isocratic sensitive and precise reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the determination and quantification of hydrocortisone in controlled-release and conventional (tablets and injections) pharmaceutical preparations. Chromatographic separation was achieved on an ODS (C18), 5??m, 4.6 ? 150?mm, with an isocratic elution using a freshly prepared mobile phase of composition methanol?:?water?:?acetic acid (60?:?30?:?10, v/v/v) at ...

  10. Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study.

    Science.gov (United States)

    Parsa, Ehsan; Saroukhani, Sepideh; Majlessi, Fereshteh; Poorhosseini, Hamidreza; Lofti-Tokaldany, Masoumeh; Jalali, Arash; Salarifar, Mojtaba; Nematipour, Ebrahim; Alidoosti, Mohammad; Aghajani, Hassan; Amirzadegan, Alireza; Kassaian, Seyed Ebrahim

    2016-04-01

    We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421-1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent.

  11. Elution behaviors of elements from the hair

    International Nuclear Information System (INIS)

    Akashi, Junko; Fukushima, Ichiro; Imahori, Akira

    1981-01-01

    The elution of the neutron activated elements out of hair soaked in some organic solvents and EDTA solution was studied. Soakage of the hair sample, which was washed with water and acetone in advance as IAEA's proposal, in ether and acetone for 30 minutes each resulted in no elution of Hg, Zn, Co and Se. Elution of Zn and Co from the powdered hair sample soaked in 0.1 M EDTA solution was rapid, while Zn did not elute out from the cut hair (2 -- 3 mm length) on the same condition. Hg, Se and Au were not eluted out by 0.1 M EDTA solution in the both case of cut hair and of powdered hair. Br was removed by 0.1 M EDTA solution from the cut hair and from the powdered hair with equal ease. (author)

  12. Isocratic Solid Phase Extraction-Liquid Chromatography (SPE-LC) Interfaced to High-Performance Tandem Mass Spectrometry for Rapid Protein Identification

    DEFF Research Database (Denmark)

    Hørning, Ole B; Kjeldsen, Frank; Theodorsen, Søren

    2008-01-01

    the isocratic solid phase extraction-liquid chromatography (SPE-LC) technology for rapid separation ( approximately 8 min) of simple peptide samples. We now extend these studies to demonstrate the potential of SPE-LC separation in combination with a hybrid linear ion trap-Orbitrap tandem mass spectrometer...

  13. Modulator Dynamics Shape the Design Space for Stepwise-Elution Simulated Moving Bed Chromatographic Separations.

    Science.gov (United States)

    Wayne, Chris J; Velayudhan, Ajoy

    2018-03-31

    For proteins and other biological macromolecules, SMB chromatography is best operated non-isocratically. However, traditional modes of non-isocratic SMB operation generate significant mobile-phase modulator dynamics. The mechanisms by which these modulator dynamics affect a separation's success, and thus frame the design space, have yet to be explained quantitatively. Here, the dynamics of the modulator (e.g., salts in ion exchange and hydrophobic interaction chromatography) are explicitly accounted for. This leads to the elucidation of two new design constraints, presented as dimensionless numbers, which quantify the effects of the modulator phenomena and thus predict the success of a non-isocratic SMB separation. Consequently, these two new design constraints re-define the SMB design space. Computational and experimental studies at the boundaries of this design space corroborate the theoretical predictions. The design of efficient and robust operating conditions through use of the new design space is also demonstrated. © 2018 The Authors. Biotechnology Journal Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. The prognostic utility of the SYNTAX score on 1-year outcomes after revascularization with zotarolimus- and everolimus-eluting stents: a substudy of the RESOLUTE All Comers Trial

    DEFF Research Database (Denmark)

    Garg, Scot; Serruys, Patrick W; Silber, Sigmund

    2011-01-01

    This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents.......This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents....

  15. Large-scale separation of amino acids by continuous displacement chromatography

    Energy Technology Data Exchange (ETDEWEB)

    DeCarli, J.P. II; Carta, G.; Byers, C.H.

    1989-10-01

    Continuous annular chromatography (CAC) is a developing technology that allows truly continuous chromatographic separations. Previous work has demonstrated the utility of this technology for the separation of various materials by isocratic elution on a bench scale. Novel applications and improved operation of the process were studied in this work, demonstrating that CAC is a versatile apparatus which is capable of separations at high throughput. Three specific separation systems were investigated. Pilot-scale separations at high loadings were performed using an industrial sugar mixture as an example of scale-up for isocratic separations. Bench-scale experiments of a low concentration metal ion mixture were performed to demonstrate stepwise elution, a chromatographic technique which decreases dilution and increases sorbent capacity. Finally, the separation of mixtures of amino acids by ion exchange was investigated to demonstrate the use of displacement development on the CAC. This technique, which perhaps has the most potential, when applied to the CAC allowed simultaneous separation and concentration of multicomponent mixtures on a continuous basis. Mathematical models were developed to describe the CAC performance and optimize the operating conditions. For all the systems investigated, the continuous separation performance of the CAC was found to be very nearly the same as the batchwise performance of conventional chromatography. The technology appears, thus, to be very promising for industrial applications.

  16. Advanced techniques for energy-efficient industrial-scale continuous chromatography

    Energy Technology Data Exchange (ETDEWEB)

    DeCarli, J.P. II (Dow Chemical Co., Midland, MI (USA)); Carta, G. (Virginia Univ., Charlottesville, VA (USA). Dept. of Chemical Engineering); Byers, C.H. (Oak Ridge National Lab., TN (USA))

    1989-11-01

    Continuous annular chromatography (CAC) is a developing technology that allows truly continuous chromatographic separations. Previous work has demonstrated the utility of this technology for the separation of various materials by isocratic elution on a bench scale. Novel applications and improved operation of the process were studied in this work, demonstrating that CAC is a versatile apparatus which is capable of separations at high throughput. Three specific separation systems were investigated. Pilot-scale separations at high loadings were performed using an industrial sugar mixture as an example of scale-up for isocratic separations. Bench-scale experiments of a low concentration metal ion mixture were performed to demonstrate stepwise elution, a chromatographic technique which decreases dilution and increases sorbent capacity. Finally, the separation of mixtures of amino acids by ion exchange was investigated to demonstrate the use of displacement development on the CAC. This technique, which perhaps has the most potential, when applied to the CAC allowed simultaneous separation and concentration of multicomponent mixtures on a continuous basis. Mathematical models were developed to describe the CAC performance and optimize the operating conditions. For all the systems investigated, the continuous separation performance of the CAC was found to be very nearly the same as the batchwise performance of conventional chromatography. the technology appears, thus, to be very promising for industrial applications. 43 figs., 9 tabs.

  17. Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V)

    DEFF Research Database (Denmark)

    Christiansen, Evald Høj; Jensen, Lisette Okkels; Thayssen, Per

    2013-01-01

    Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer......-coated sirolimus-eluting stent in a population-based setting....

  18. Intimal hyperplasia and vascular remodeling after everolimus-eluting and sirolimus-eluting stent implantation in diabetic patients the randomized diabetes and drug-eluting stent (DiabeDES) IV intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Maeng, Michael; Thayssen, Per

    2013-01-01

    OBJECTIVE: To evaluate the effects of the everolimus-eluting Xience™/Promus™ stent (EES) and the sirolimus-eluting Cypher™ stent (SES) on intimal hyperplasia (IH) in diabetic patients. BACKGROUND: Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent...... implantation due to intimal hyperplasia (IH). METHODS: In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available...... in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume. RESULTS: Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0...

  19. Production of 99Tc generators with automatic elution

    International Nuclear Information System (INIS)

    Mengatti, J.; Yanagawa, S.T.I.; Mazzarro, E.; Gasiglia, H.T.; Rela, P.R.; Silva, C.P.G. da; Pereira, N.P.S. de.

    1983-10-01

    The improvements performed on the routine production of sup(99m) Tc-generators at the Instituto de Pesquisas Energeticas e Nucleares-CNEN/SP, are described. The old model generators (manual elution of sup(99m) Tc) were substituted by automatically eluted generators (Vacuum system). The alumina column, elution system and acessories were modified; the elution time was reduced from 60 to 20-30 seconds. The new generators give 80-90% elution yields using six mililiters of sodium chloride 0,9% as sup(99m) Tc eluant instead of the 10 mililiters necessary to eluate the old generators. So, the radioactive concentrations are now 70% higher. The radioactive, radiochemical, chemical and microbiological criteria were examinated for sup(99m) Tc solutions. Like old generators, automatic generators were considered safe for medical purpose. (Author) [pt

  20. Incorporating high-pressure electroosmotic pump and a nano-flow gradient generator into a miniaturized liquid chromatographic system for peptide analysis.

    Science.gov (United States)

    Chen, Apeng; Lynch, Kyle B; Wang, Xiaochun; Lu, Joann J; Gu, Congying; Liu, Shaorong

    2014-09-24

    We integrate a high-pressure electroosmotic pump (EOP), a nanoflow gradient generator, and a capillary column into a miniaturized liquid chromatographic system that can be directly coupled with a mass spectrometer for proteomic analysis. We have recently developed a low-cost high-pressure EOP capable of generating pressure of tens of thousands psi, ideal for uses in miniaturized HPLC. The pump worked smoothly when it was used for isocratic elutions. When it was used for gradient elutions, generating reproducible gradient profiles was challenging; because the pump rate fluctuated when the pump was used to pump high-content organic solvents. This presents an issue for separating proteins/peptides since high-content organic solvents are often utilized. In this work, we solve this problem by incorporating our high-pressure EOP with a nano-flow gradient generator so that the EOP needs only to pump an aqueous solution. With this combination, we develop a capillary-based nano-HPLC system capable of performing nano-flow gradient elution; the pump rate is stable, and the gradient profiles are reproducible and can be conveniently tuned. To demonstrate its utility, we couple it with either a UV absorbance detector or a mass spectrometer for peptide separations. Copyright © 2014. Published by Elsevier B.V.

  1. Effect of Post-Dilatation Following Primary PCI With Everolimus-Eluting Bioresorbable Scaffold Versus Everolimus-Eluting Metallic Stent Implantation

    DEFF Research Database (Denmark)

    Yamaji, Kyohei; Brugaletta, Salvatore; Sabaté, Manel

    2017-01-01

    OBJECTIVES: This study sought to investigate the effect of post-dilatation on angiographic and intracoronary imaging parameters in the setting of primary percutaneous coronary intervention comparing the everolimus-eluting bioresorbable scaffold (BRS) with the everolimus-eluting metallic stent (EE...

  2. Theory and applications of a novel ion exchange chromatographic technology using controlled pH gradients for separating proteins on anionic and cationic stationary phases.

    Science.gov (United States)

    Tsonev, Latchezar I; Hirsh, Allen G

    2008-07-25

    pISep is a major new advance in low ionic strength ion exchange chromatography. It enables the formation of externally controlled pH gradients over the very broad pH range from 2 to 12. The gradients can be generated on either cationic or anionic exchangers over arbitrary pH ranges wherein the stationary phases remain totally charged. Associated pISep software makes possible the calculation of either linear, nonlinear or combined, multi-step, multi-slope pH gradients. These highly reproducible pH gradients, while separating proteins and glycoproteins in the order of their electrophoretic pIs, provide superior chromatographic resolution compared to salt. This paper also presents a statistical mechanical model for protein binding to ion exchange stationary phases enhancing the electrostatic interaction theory for the general dependence of retention factor k, on both salt and pH simultaneously. It is shown that the retention factors computed from short time isocratic salt elution data of a model protein can be used to accurately predict its salt elution concentration in varying slope salt elution gradients formed at varying isocratic pH as well as the pH at which it will be eluted from an anionic exchange column by a pISep pH gradient in the absence of salt.

  3. Predicting the chromatographic retention of polymers: application of the polymer model to poly(styrene/ethylacrylate)copolymers.

    Science.gov (United States)

    Bashir, Mubasher A; Radke, Wolfgang

    2012-02-17

    The retention behavior of a range of statistical poly(styrene/ethylacrylate) copolymers is investigated, in order to determine the possibility to predict retention volumes of these copolymers based on a suitable chromatographic retention model. It was found that the composition of elution in gradient chromatography of the copolymers is closely related to the eluent composition at which, in isocratic chromatography, the transition from elution in adsorption to exclusion mode occurs. For homopolymers this transition takes place at a critical eluent composition at which the molar mass dependence of elution volume vanishes. Thus, similar critical eluent compositions can be defined for statistical copolymers. The existence of a critical eluent composition is further supported by the narrower peak width, indicating that the broad molar mass distribution of the samples does not contribute to the retention volume. It is shown that the existing retention model for homopolymers allows for correct quantitative predictions of retention volumes based on only three appropriate initial experiments. The selection of these initial experiments involves a gradient run and two isocratic experiments, one at the composition of elution calculated from first gradient run and second at a slightly higher eluent strength. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Optimization of elution salt concentration in stepwise elution of protein chromatography using linear gradient elution data. Reducing residual protein A by cation-exchange chromatography in monoclonal antibody purification.

    Science.gov (United States)

    Ishihara, Takashi; Kadoya, Toshihiko; Endo, Naomi; Yamamoto, Shuichi

    2006-05-05

    Our simple method for optimization of the elution salt concentration in stepwise elution was applied to the actual protein separation system, which involves several difficulties such as detection of the target. As a model separation system, reducing residual protein A by cation-exchange chromatography in human monoclonal antibody (hMab) purification was chosen. We carried out linear gradient elution experiments and obtained the data for the peak salt concentration of hMab and residual protein A, respectively. An enzyme-linked immunosorbent assay was applied to the measurement of the residual protein A. From these data, we calculated the distribution coefficient of the hMab and the residual protein A as a function of salt concentration. The optimal salt concentration of stepwise elution to reduce the residual protein A from the hMab was determined based on the relationship between the distribution coefficient and the salt concentration. Using the optimized condition, we successfully performed the separation, resulting in high recovery of hMab and the elimination of residual protein A.

  5. Determinants of protein elution rates from preparative ion-exchange adsorbents.

    Science.gov (United States)

    Angelo, James M; Lenhoff, Abraham M

    2016-04-01

    The rate processes involved in elution in preparative chromatography can affect both peak resolution and hence selectivity as well as practical factors such as facility fit. These processes depend on the physical structure of the adsorbent particles, the amount of bound solute, the solution conditions for operation or some combination of these factors. Ion-exchange adsorbents modified with covalently attached or grafted polymer layers have become widely used in preparative chromatography. Their often easily accessible microstructures offer substantial binding capacities for biomolecules, but elution has sometimes been observed to be undesirably slow. In order to determine which physicochemical phenomena control elution behavior, commercially available cellulosic, dextran-grafted and unmodified agarose materials were characterized here by their elution profiles at various conditions, including different degrees of loading. Elution data were analyzed under the assumption of purely diffusion-limited control, including the role of pore structure properties such as porosity and tortuosity. In general, effective elution rates decreased with the reduction of accessible pore volume, but differences among different proteins indicated the roles of additional factors. Additional measurements and analysis, including the use of confocal laser scanning microscopy to observe elution within single chromatographic particles, indicated the importance of protein association within the particle during elution. The use of protein stabilizing agents was explored in systems presenting atypical elution behavior, and l-arginine and disaccharide excipients were shown to alleviate the effects for one protein, lysozyme, in the presence of sodium chloride. Incorporation of these excipients into eluent buffer gave rise to faster elution and significantly lower pool volumes in elution from polymer-modified adsorbents. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who we...

  7. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; Cuesta, Javier; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José Ramón; Masotti, Mónica; Zueco, Javier; Cequier, Angel; Velázquez, Maite; Moreno, Raúl; Mainar, Vicente; Domínguez, Antonio; Moris, Cesar; Molina, Eduardo; Rivero, Fernando; Jiménez-Quevedo, Pilar; Gonzalo, Nieves; Fernández-Pérez, Cristina

    2018-05-28

    This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). Treatment of patients with DES-ISR remains a challenge. The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p 1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940). Published by Elsevier Inc.

  8. An Isocratic Toxic Chemical-Free Mobile Phase HPLC-PDA Analysis of Malachite Green and Leuco-Malachite Green

    OpenAIRE

    Furusawa, Naoto

    2014-01-01

    This paper describes a reserved-phase high-performance liquid chromatographic (HPLC) method for detecting malachite green (MG) and leuco-malachite green (LMG) using an isocratic toxic organic solvent/reagent-free mobile phase. Chromatographic separations were performed an Inertsil® WP300 C4 with 0.02 mol/L octane sulfonic acid–ethanol mobile phase and a photodiode-array detector. The total run time was <5 min. The system suitability was well within the international acceptance criteria. A...

  9. Enhancing cognate target elution efficiency in gel-free chemical proteomics

    Directory of Open Access Journals (Sweden)

    Branka Radic-Sarikas

    2015-12-01

    Full Text Available Gel-free liquid chromatography mass spectrometry coupled to chemical proteomics is a powerful approach for characterizing cellular target profiles of small molecules. We have previously described a fast and efficient elution protocol; however, altered target profiles were observed. We hypothesised that elution conditions critically impact the effectiveness of disrupting drug-protein interactions. Thus, a number of elution conditions were systematically assessed with the aim of improving the recovery of all classes of proteins whilst maintaining compatibility with immunoblotting procedures. A double elution with formic acid combined with urea emerged as the most efficient and generically applicable elution method for chemical proteomics

  10. Size distribution of DNA molecules recovered from non-denaturing filter elution

    International Nuclear Information System (INIS)

    Bloecher, D.; Iliakis, G.

    1991-01-01

    DNA fragments removed from the filter during non-denaturing filter elution were collected and loaded on top of neutral sucrose gradients. Their size distribution was determined by low-speed centrifugation in neutral sucrose gradients. The average size of eluted DNA was found to be approximately 110 S; the average size of DNA collected after short elution times was found to be slightly larger than after long elution times. It is concluded that the size of eluted DNA fragments is not correlated with elution rate, and it is proposed that shear forces generated at the filter pores cause degradation of the DNA. Comparison of sedimentation profiles of carefully prepared cellular DNA before and after elution revealed that generated shear forces during elution break down DNA to an extent equivalent to around 20 000 DNA double-strand breaks (dsb) per G 1 cell. The size of DNA fragments decreased with increasing radiation dose; five times more dsb were found than expected after exposure to radiation alone. It is proposed that excess of dsb may derive from the transformation of other radiation-induced lesions to dsb under the action of shear forces generated during elution. (author)

  11. The Indicating FTA Elute Cartridge

    Science.gov (United States)

    de Bie, Roosmarie P.; Schmeink, Channa E.; Bakkers, Judith M.J.E.; Snijders, Peter J.F.; Quint, Wim G.V.; Massuger, Leon F.A.G.; Bekkers, Ruud L.M.; Melchers, Willem J.G.

    2011-01-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were compared with liquid-based samples for hrHPV and high-grade cervical intraepithelial neoplasia (CIN) detection. One cervical sample was collected in a liquid-based medium, and one was applied to the FTA cartridge. DNA was eluted directly from the FTA cartridge by a simple elution step. HC2 and GP5+/6+-PCR assays were performed on both the liquid-based and the FTA-eluted DNA of 88 women. Overall agreement between FTA and liquid-based samples for the presence of hrHPV was 90.9% with GP5+/6+-PCR and 77.3% with HC2. The sensitivity for high-grade CIN of hrHPV testing on the FTA cartridges was 84.6% with GP5+/6+-PCR and only 53.8% with HC2. By comparison, these sensitivities on liquid-based samples were 92.3% and 100% for GP5+/6+-PCR and HC2, respectively. Therefore, the FTA cartridge shows reasonably good overall agreement for hrHPV detection with liquid-based media when using GP5+/6+-PCR but not HC2 testing. Even with GP5+/6+-PCR, the FTA cartridge is not yet capable of detecting all high-grade CIN lesions. PMID:21704269

  12. Zotarolimus-eluting durable-polymer-coated stent versus a biolimus-eluting biodegradable-polymer-coated stent in unselected patients undergoing percutaneous coronary intervention (SORT OUT VI)

    DEFF Research Database (Denmark)

    Raungaard, Bent; Jensen, Lisette Okkels; Tilsted, Hans-Henrik

    2015-01-01

    BACKGROUND: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety...... and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent. METHODS: This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All......-polymer zotarolimus-eluting stent or the biodegradable-polymer biolimus-eluting stent. The primary endpoint was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target-lesion revascularisation) at 12 months, analysed by intention to treat...

  13. Nickel elution properties of contemporary interatrial shunt closure devices.

    Science.gov (United States)

    Verma, Divya Ratan; Khan, Muhammad F; Tandar, Anwar; Rajasekaran, Namakkal S; Neuharth, Renée; Patel, Amit N; Muhlestein, Joseph B; Badger, Rodney S

    2015-02-01

    We sought to compare nickel elution properties of contemporary interatrial shunt closure devices in vitro. There are two United States Food and Drug Administration (FDA)-approved devices for percutaneous closure of secundum atrial septal defect: the Amplatzer septal occluder (ASO; St Jude Medical Corporation) and Gore Helex septal occluder (HSO; W.L. Gore & Associates). The new Gore septal occluder (GSO) device is in clinical trials. These are also used off-label for patent foramen ovale closure in highly selected patients. These devices have high nickel content. Nickel allergy is the most common reason for surgical device explantation. Nickel elution properties of contemporary devices remain unknown. We compared nickel elution properties of 4 devices - ASO, GSO, HSO, and sternal wire (SW) - while Dulbecco's phosphate-buffered saline (DPBS) served as control. Three samples of each device were submerged in DPBS. Nickel content was measured at 14 intervals over 90 days. Nickel elution at 24 hours, compared to control (0.005 ± 0.0 mg/L), was significantly higher for ASO (2.98 ± 1.65 mg/L; P=.04) and SW (0.03 ± 0.014 mg/L; P=.03). Nickel levels at 90 days, compared to control (0.005 ± 0.0 mg/L) and adjusting for multiple comparisons, were significantly higher for ASO (19.80 ± 2.30 mg/L; P=.01) and similar for HSO (P=.34), GSO (P=.34), and SW (P=.34). ASO had significantly higher nickel elution compared to HSO, GSO, and SW (P=.01). There is substantial variability in nickel elution; devices with less exposed nickel (HSO and GSO) have minimal elution. The safety of low nickel elution devices in patients with nickel allergy needs to be evaluated in prospective trials.

  14. Alkaline elution of DNA from mammalian cells on cellulose triacetate filters

    International Nuclear Information System (INIS)

    Moss, A.J. Jr.; Nagle, W.A.; Henle, K.J.; Prior, R.M.

    1984-01-01

    The alkaline elution technique is widely used for the estimation of cellular DNA damage because of its sensitivity in the biologically relevant dose range. The authors have extended the original studies and provide additional characterization of the cellulose triacetate alkaline elution method. This filter material permits the elution of approximately 80 percent of cellular DNA from untreated V79 cells. the total radioactivity in the system was compartmentalized with respect to 1) lysing solution, 2) washing solution, 3) elution fractions, and 4) membrane retained activity. In these studies [/sup 3/H]-thymidine labeled untreated internal control cells were co-eluted with X-irradiated [/sup 14/C]-thymidine labeled cells. For the estimation of DNA damage, elution profiles for treated cells were directly compared with untreated internal control cells. The quantity of DNA eluting in excess of the labeled internal control per fraction is directly proportional to the extent of DNA damage in the treated sample. Using the technique the necessity of an irradiated internal control is eliminated

  15. Evaluation on elution feature of bentonite buffer materials

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Hirohisa; Kanno, Takeshi; Matsumoto, Kazuhiro

    1997-09-01

    In order to evaluate long term physical stability of artificial barrier in land disposal of high level radioactive wastes, it is necessary to know quantitatively elution behavior of buffering materials from disposal road (or cavity) to circumferential rock crack. When elution of the buffer material occurs on large scale, amount of bentonite in the disposal road (or cavity) reduces and reduction of various functions expected to the buffer materials is presumed. According to specification examples of road transverse arrangement and disposal vertical arrangement systems, evaluation on elution amount of the buffer materials at disposal environment was conducted. Opening width of rock crack in the disposal environment was supposed to be 0.5 mm. As a result, obtained mass elution ratios of the buffer materials due to extrusion phenomenon were 0.04 to 0.2% after 10,000 year and 2 to 12% after 1,000,000 years. (G.K.)

  16. Determination of caffeine, theobromine, and theophylline in standard reference material 2384, baking chocolate, using reversed-phase liquid chromatography.

    Science.gov (United States)

    Thomas, Jeanice Brown; Yen, James H; Schantz, Michele M; Porter, Barbara J; Sharpless, Katherine E

    2004-06-02

    A rapid and selective isocratic reversed-phase liquid chromatographic method has been developed at the National Institute of Standards and Technology to simultaneously measure caffeine, theobromine, and theophylline in a food-matrix standard reference material (SRM) 2384, Baking Chocolate. The method uses isocratic elution with a mobile phase composition (volume fractions) of 10% acetronitrile/90% water (pH adjusted to 2.5 using acetic acid) at a flow rate of 1.5 mL/min with ultraviolet absorbance detection (274 nm). Total elution time for these analytes is less than 15 min. Concentration levels of caffeine, theobromine, and theophylline were measured in single 1-g samples taken from each of eight bars of chocolate over an eight-day period. Samples were defatted with hexane, and beta-hydroxyethyltheophylline was added as the internal standard. The repeatability for the caffeine, theobromine, and theophylline measurements was 5.1, 2.3, and 1.9%, respectively. The limit of quantitation for all analytes was theobromine, and theophylline in SRM 2384.

  17. 2-year clinical outcomes after implantation of sirolimus-eluting, paclitaxel-eluting, and bare-metal coronary stents: results from the WDHR (Western Denmark Heart Registry)

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Jensen, Lisette Okkels; Maeng, Michael

    2009-01-01

    OBJECTIVES: This registry study assessed the safety and efficacy of the 2 types of drug-eluting stents (DES), sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES), compared with bare-metal stents (BMS). BACKGROUND: Drug-eluting stents may increase the risk of stent thrombosis (ST...... databases. We used Cox regression analysis to control for confounding. RESULTS: The 2-year incidence of definite ST was 0.64% in BMS patients, 0.79% in DES patients (adjusted relative risk [RR]: 1.09; 95% confidence interval [CI]: 0.72 to 1.65), 0.50% in SES patients (adjusted RR: 0.63, 95% CI: 0.35 to 1...

  18. A prospective, randomized evaluation of a novel everolimus-eluting coronary stent

    DEFF Research Database (Denmark)

    Stone, Gregg W; Teirstein, Paul S; Meredith, Ian T

    2011-01-01

    We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI).......We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI)....

  19. EVALUATION OF PETROLEUM HYDROCARBONS ELUTION FROM SOIL

    Directory of Open Access Journals (Sweden)

    Janina Piekutin

    2015-06-01

    Full Text Available The paper presents studies on oil removal from soil by means of water elution with a help of shaking out the contaminants from the soil. The tests were performed on simulated soil samples contaminated with a mixture of petroleum hydrocarbons. The study consisted in recording the time influence and the number of elution cycles to remove contaminants from the soil. The samples were then subject to the determination of petroleum hydrocarbons, aliphatic hydrocarbons, and BTEX compounds (benzene, toluene, ethylbenzene, xylene. Due to adding various concentrations of petroleum into particular soil samples and applying different shaking times, it was possible to find out the impact of petroleum content and sample shaking duration on the course and possibility of petroleum substances removal by means of elution process.

  20. Differential clinical outcomes after 1 year versus 5 years in a randomised comparison of zotarolimus-eluting and sirolimus-eluting coronary stents (the SORT OUT III study)

    DEFF Research Database (Denmark)

    Maeng, Michael; Tilsted, Hans Henrik; Jensen, Lisette Okkels

    2014-01-01

    received two different types of drug-eluting stents. METHODS: We undertook this multicentre, open-label, randomised superiority trial at five percutaneous coronary intervention centres in Denmark. We randomly allocated 2332 eligible adult patients (≥18 years of age) with an indication for drug......-eluting stent implantation to the zotarolimus-eluting Endeavor Sprint stent (Medtronic, Santa Rosa, CA, USA) or the sirolimus-eluting Cypher Select Plus stent (Cordis, Johnson & Johnson, Warren, NJ, USA). Randomisation of participants was achieved by computer-generated block randomisation and a telephone...

  1. Sensitive determination of nitrophenol isomers by reverse-phase high-performance liquid chromatography in conjunction with liquid-liquid extraction

    Science.gov (United States)

    A method for the highly sensitive determination of 2-, 3- and 4- nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the i...

  2. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II)

    DEFF Research Database (Denmark)

    Serruys, Patrick W; Chevalier, Bernard; Sotomi, Yohei

    2016-01-01

    BACKGROUND: No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrate two mechanistic properties of the bioresorbable scaffold: increase in luminal dimensions as a re...

  3. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Mæng, Michael; Thayssen, Per

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects...... of the sirolimus-eluting Cypher® stent (SES) and the zotarolimus-eluting Endeavor® stent (ZES) on angiographic late lumen loss and intima hyperplasia in diabetic patients....

  4. All-cause mortality after drug-eluting stent implantation in African-Americans.

    Science.gov (United States)

    Poludasu, Shyam; Cavusoglu, Erdal; Khan, Waqas; Marmur, Jonathan D

    2008-12-01

    Recent studies have questioned the safety of drug-eluting stents because of a higher incidence of late stent thrombosis, raising the possibility that drug-eluting stents may be associated with an increased mortality. The effect of drug-eluting stents on mortality in African-Americans is unknown. We evaluated 628 African-American patients (354 patients treated with drug-eluting stents and 274 patients treated with bare metal stents) between January 2003 and August 2005, using data from our bolus-only platelet glycoprotein IIb/IIIa inhibitor database. The primary end point was all-cause mortality obtained using social security death index. After a mean follow-up of 3+/-0.9 years, the mortality rate in the bare metal stents group was 12.8% compared with 7.1% in the drug-eluting stents group [adjusted P value=0.19; hazard ratio (HR) for bare metal stents group compared with drug-eluting stents group for death=1.4; 95% confidence interval (CI): 0.8-2.4]. In a subgroup analysis, patients presenting with acute coronary syndrome had a higher mortality when treated with bare metal stents compared with drug-eluting stents (17.1 vs. 6.3%, P=0.022; HR=2.2; 95% CI: 1.1-4.4). Patients with chronic kidney disease (all patients with creatinine >1.5 mg/dl) also had a higher mortality with bare metal stents compared with drug-eluting stents (36.7 vs. 20.4%, P=0.044; HR=2.3; 95% CI: 1.02-5.2). Drug-eluting stents seem to be safe in African-Americans and may improve survival in certain subgroups such as patients with acute coronary syndromes and chronic kidney disease.

  5. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    Science.gov (United States)

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, pB2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, pSPIRIT II trial population.

  6. Hypotonic elution, a new desorption principle in immunoadsorbent chromatography

    DEFF Research Database (Denmark)

    Danielsen, Erik Michael; Sjöström, H; Norén, O

    1982-01-01

    of finding an efficient means of elution which is not denaturing to neither the purified enzyme nor the immunoadsorbent column. Common properties of the microvillar enzymes with regard to amphiphilicity, glycosylation or subunit composition could hypothetically account for the similar elution properties...

  7. Drug-eluting stents for acute coronary syndrome: a meta-analysis of randomized controlled trials.

    Directory of Open Access Journals (Sweden)

    Lishan Wang

    Full Text Available Drug-eluting stents (DES are increasingly used for treatment of acute coronary syndrome (ACS. However, clinical efficacy and safety of various types of DES is not well established in these subjects. We therefore evaluated clinical utility of second-generation and first-generation DES in patients with ACS by conducting a meta-analysis.A search of Medline, Embase, the Cochrane databases, and Web of Science was made. Randomized controlled trials (RCTs which compared second-generation DES (everolimus-eluting stents [EES] or zotarolimus-eluting stents [ZES] versus first-generation DES (sirolimus-eluting stents [SES] or paclitaxe-eluting stents [PES] in patients with ACS and provided data on clinical efficacy or safety endpoints were included. Pooled estimates were calculated using random-effects model.A total of 2,757 participants with ACS in 6 RCTs were included. Compared with first-generation one, second-generation DES trended to be associated with the decreased incidence of definite or probable stent thrombosis in ACS patients (risk ratio [RR]  = 0.60, 95% confidence intervals [CI] 0.33 to 1.07, p = 0.09. However, the rate of target lesion revascularization (TLR significantly increased in second-generation DES (RR = 2.08, 95%CI 1.25 to 3.47, p = 0.005. There were no significant differences in the incidence of major adverse cardiac events (MACEs, all-cause death, cardiac death, and recurrent myocardial infarction between the two arms (all p>0.10. The second-generation EES showed a tendency towards lower risk of MACEs (p = 0.06 and a beneficial effect on reducing stent thrombosis episodes (p = 0.009, while the second-generation ZES presented an increased occurrence of MACEs (p = 0.02 and TLR (p = 0.003.Second-generation DES, especially EES, appeared to present a lower risk of stent thrombosis, whereas second-generation ZES might increase the need for repeat revascularization in ACS patients. During coronary

  8. An Isocratic Toxic Chemical-Free Mobile Phase HPLC-PDA Analysis of Malachite Green and Leuco-Malachite Green

    Directory of Open Access Journals (Sweden)

    Naoto Furusawa

    2014-05-01

    Full Text Available This paper describes a reserved-phase high-performance liquid chromatographic (HPLC method for detecting malachite green (MG and leuco-malachite green (LMG using an isocratic toxic organic solvent/reagent-free mobile phase. Chromatographic separations were performed an Inertsil® WP300 C4 with 0.02 mol/L octane sulfonic acid–ethanol mobile phase and a photodiode-array detector. The total run time was <5 min. The system suitability was well within the international acceptance criteria. A harmless method for simultaneously detecting MG and LMG was developed and may be further applied to the quantification in foods.

  9. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    Science.gov (United States)

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  10. Investigation of the elution by seawater of caesium and strontium from loaded clinoptilolite

    International Nuclear Information System (INIS)

    Harder, B.R.; Mitchell, I.H.; Smyth, M.J.

    1985-07-01

    Simple investigations of the elution of caesium and strontium from loaded clinoptilolite are described. The clinoptilolite was loaded to levels expected in the British Nuclear Fuels plc SIXEP plant and contacted with seawater at approx. 15 C. (The elution time was measured until about 99% of the caesium and strontium had been eluted.) It was found that 99% of the caesium was eluted in 35 hours but the strontium (with more variable results) took at least 400 hours for 99% elution. (author)

  11. Production and setting of fractional elution facility for recovery of useful rare metals from seawater

    International Nuclear Information System (INIS)

    Seko, Noriaki; Kasai, Noboru; Tamada, Masao; Hasegawa, Shin; Katakai, Akio

    2005-01-01

    In September 1999, we have soaked 200 kg of fibrous amidoxime absorbents, synthesized by radiation-induced graft polymerization, into seawater to evaluate their performance. Fractional elution facility was set effectively to elute the rare metals on adsorbents in Mutsu-Establishment. This facility consists of two parts of pre-washing and elution. The present report dealt with planning, manufacture and setting of fractional facility. Marine organism and slime on adsorbent cassette (290 x 295 x 160 mm) were washed out and every 72 cassettes were set in elution unit (1210 x 1210 x H1460 mm) with nonwoven materials as a packing to avoid elution loss. In the elution process alkaline and alkaline earth metals were eluted with low concentration hydrochloric acid (0.01M) and rare metals were eluted with high concentration (0.5 M) after the packing of elution unit into fractional elution facility. Adsorbent cassettes were regenerated with alkaline solution after elution procedure. (author)

  12. Long-Term Safety of Drug-Eluting and Bare-Metal Stents

    DEFF Research Database (Denmark)

    Palmerini, Tullio; Benedetto, Umberto; Biondi-Zoccai, Giuseppe

    2015-01-01

    BACKGROUND: Previous meta-analyses have investigated the relative safety and efficacy profiles of different types of drug-eluting stents (DES) and bare-metal stents (BMS); however, most prior trials in these meta-analyses reported follow-up to only 1 year, and as such, the relative long-term safety....... RESULTS: Fifty-one trials that included a total of 52,158 randomized patients with follow-up duration ≥3 years were analyzed. At a median follow-up of 3.8 years, cobalt-chromium everolimus-eluting stents (EES) were associated with lower rates of mortality, definite stent thrombosis (ST), and myocardial...... infarction than BMS, paclitaxel-eluting stents (PES), and sirolimus-eluting stents (SES) and less ST than BES. Phosphorylcholine-based zotarolimus-eluting stents had lower rates of definite ST than SES and lower rates of myocardial infarction than BMS and PES. The late rates of target...

  13. From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI

    NARCIS (Netherlands)

    Tenekecioglu, Erhan; Bourantas, Christos; Abdelghani, Mohammad; Zeng, Yaping; Silva, Rafael Cavalcante; Tateishi, Hiroki; Sotomi, Yohei; Onuma, Yoshinobu; Yılmaz, Mustafa; Serruys, Patrick W.

    2016-01-01

    Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir

  14. Exploration of overloaded cation exchange chromatography for monoclonal antibody purification.

    Science.gov (United States)

    Liu, Hui F; McCooey, Beth; Duarte, Tiago; Myers, Deanna E; Hudson, Terry; Amanullah, Ashraf; van Reis, Robert; Kelley, Brian D

    2011-09-28

    Cation exchange chromatography using conventional resins, having either diffusive or perfusive flow paths, operated in bind-elute mode has been commonly employed in monoclonal antibody (MAb) purification processes. In this study, the performance of diffusive and perfusive cation exchange resins (SP-Sepharose FF (SPSFF) and Poros 50HS) and a convective cation exchange membrane (Mustang S) and monolith (SO(3) Monolith) were compared. All matrices were utilized in an isocratic state under typical binding conditions with an antibody load of up to 1000 g/L of chromatographic matrix. The dynamic binding capacity of the cation exchange resins is typically below 100 g/L resin, so they were loaded beyond the point of anticipated MAb break through. All of the matrices performed similarly in that they effectively retained host cell protein and DNA during the loading and wash steps, while antibody flowed through each matrix after its dynamic binding capacity was reached. The matrices differed, though, in that conventional diffusive and perfusive chromatographic resins (SPSFF and Poros 50HS) demonstrated a higher binding capacity for high molecular weight species (HMW) than convective flow matrices (membrane and monolith); Poros 50HS displayed the highest HMW binding capacity. Further exploration of the conventional chromatographic resins in an isocratic overloaded mode demonstrated that the impurity binding capacity was well maintained on Poros 50HS, but not on SPSFF, when the operating flow rate was as high as 36 column volumes per hour. Host cell protein and HMW removal by Poros 50HS was affected by altering the loading conductivity. A higher percentage of host cell protein removal was achieved at a low conductivity of 3 mS/cm. HMW binding capacity was optimized at 5 mS/cm. Our data from runs on Poros 50HS resin also showed that leached protein A and cell culture additive such as gentamicin were able to be removed under the isocratic overloaded condition. Lastly, a MAb

  15. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    Science.gov (United States)

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the

  16. Current manufacturing processes of drug-eluting sutures.

    Science.gov (United States)

    Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine

    2017-11-01

    Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.

  17. Towards enhanced automated elution systems for waterborne protozoa using megasonic energy.

    Science.gov (United States)

    Horton, B; Katzer, F; Desmulliez, M P Y; Bridle, H L

    2018-02-01

    Continuous and reliable monitoring of water sources for human consumption is imperative for public health. For protozoa, which cannot be multiplied efficiently in laboratory settings, concentration and recovery steps are key to a successful detection procedure. Recently, the use of megasonic energy was demonstrated to recover Cryptosporidium from commonly used water industry filtration procedures, forming thereby a basis for a simplified and cost effective method of elution of pathogens. In this article, we report the benefits of incorporating megasonic sonication into the current methodologies of Giardia duodenalis elution from an internationally approved filtration and elution system used within the water industry, the Filta-Max®. Megasonic energy assisted elution has many benefits over current methods since a smaller final volume of eluent allows removal of time-consuming centrifugation steps and reduces manual involvement resulting in a potentially more consistent and more cost-effective method. We also show that megasonic sonication of G. duodenalis cysts provides the option of a less damaging elution method compared to the standard Filta-Max® operation, although the elution from filter matrices is not currently fully optimised. A notable decrease in recovery of damaged cysts was observed in megasonic processed samples, potentially increasing the abilities of further genetic identification options upon isolation of the parasite from a filter sample. This work paves the way for the development of a fully automated and more cost-effective elution method of Giardia from water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Separation of polyethylene glycols and amino-terminated polyethylene glycols by high-performance liquid chromatography under near critical conditions.

    Science.gov (United States)

    Wei, Y-Z; Zhuo, R-X; Jiang, X-L

    2016-05-20

    The separation and characterization of polyethylene glycols (PEGs) and amino-substituted derivatives on common silica-based reversed-phase packing columns using isocratic elution is described. This separation is achieved by liquid chromatography under the near critical conditions (LCCC), based on the number of amino functional end groups without obvious effect of molar mass for PEGs. The mobile phase is acetonitrile in water with an optimal ammonium acetate buffer. The separation mechanism of PEG and amino-substituted PEG under the near LCCC on silica-based packing columns is confirmed to be ion-exchange interaction. Under the LCCC of PEG backbone, with fine tune of buffer concentration, the retention factor ratios for benzylamine and phenol in buffered mobile phases, α(benzylamine/phenol)-values, were used to assess the ion-exchange capacity on silica-based reversed-phase packing columns. To the best of our knowledge, this is the first report on separation of amino-functional PEGs independent of the molar mass by isocratic elution using common C18 or phenyl reversed-phase packing columns. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Veres, M.; Tóth, S.; Koós, M. [Research Institute for Solid State Physics and Optics, Budapest (Hungary); Beiler, B. [Institute of Isotopes, HAS, Budapest (Hungary)

    2009-07-01

    Drug-eluting stents have several advantages over bare metal implants. They eliminate restenosis, the main drawback of bare metal stents. In addition the locally delivered drug is more effective and causes less side-effects. However in some cases dangerous stent thrombosis, inflammatory and allergy reactions were observed after their implantation, which first of all related to the drug-eluting coating. This project is aimed to develop a novel biocompatible nanoporous polymer layer by radiation induced polymerization that is capable of holding and eluting drugs and promotes endothelization after the release of the drug. (author)

  20. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    International Nuclear Information System (INIS)

    Veres, M.; Tóth, S.; Koós, M.; Beiler, B.

    2009-01-01

    Drug-eluting stents have several advantages over bare metal implants. They eliminate restenosis, the main drawback of bare metal stents. In addition the locally delivered drug is more effective and causes less side-effects. However in some cases dangerous stent thrombosis, inflammatory and allergy reactions were observed after their implantation, which first of all related to the drug-eluting coating. This project is aimed to develop a novel biocompatible nanoporous polymer layer by radiation induced polymerization that is capable of holding and eluting drugs and promotes endothelization after the release of the drug. (author)

  1. Radioactive cesium elution speed in dried wild Mushrooms collected in 2015

    International Nuclear Information System (INIS)

    Yamaguchi, Toshiro; Arai, Hirotsugu; Ohnuma, Tohru; Arai, Hiromu; Takyu, Sodai; Matsuyama, Tetsuo; Ishii, Keizo

    2016-01-01

    Dried wild mushrooms (12 species, 13 samples) collected in Nagano, Fukushima, and Miyagi Prefectures, Japan, in 2015 were immersed in water for 1,440 min. The elution rate of radioactive cesium (Cs) was calculated based on its radioactivity, which was measured with a high-purity germanium semiconductor detector (GX2018; CANBERRA Industries, Meriden, CT, USA) before and after immersion for each mushroom. Immersion fluid was sampled after 10, 30, 60, 180, 360, and 1,440 min of immersion and dried on aluminum foil. Then, imaging plates (BAS-III, Fujifilm, Tokyo, Japan) exposed to the dried immersion fluid were measured with a Bio-imaging Analyzer System-1800 II (Fujifilm). The 50% elution time of each wild mushroom was calculated based on the photo stimulated luminescence density of the autoradiographs. The radioactive Cs elution rate was > 80% for 11 samples (84% of total) comprising 11 mushroom species. Moreover, the 50% elution time was < 30 min for 9 samples (69% of total) comprising 9 species. This shows that the radioactive Cs elution rate and elution speed were not constant among mushroom species. Based on these results, immersing the mushrooms, which were dried, in water for at least 120 min is an effective method for removing radioactive Cs from wild mushrooms. (author)

  2. High Performance Liquid Chromatographic Determination of ...

    African Journals Online (AJOL)

    150 mm×4.6 mm, 5μm) by isocratic elution at 25oC The mobile phase consisted of phosphate buffered saline (pH = 4.5) and methanol (40/60, v/v). The flow rate was set at 0.8 ml/min and the effluent was monitored using a DAD set at 260 nm.

  3. Elution of lead from lead zirconate titanate ceramics to acid rain

    Science.gov (United States)

    Tsurumi, Takaaki; Takezawa, Shuhei; Hoshina, Takuya; Takeda, Hiroaki

    2017-10-01

    The amount of lead that eluted from lead zirconate titanate (PZT) ceramics to artificial acid rain was evaluated. Four kinds of PZT ceramics, namely, pure PZT at MPB composition, CuO-added PZT, PZT with 10 mol % substitution of Ba for Pb, and CuO-added PZT with 10 mol % substitution of Ba for Pb, were used as samples of the elution test. These PZT ceramics of 8 mm2 and 1.1-1.2 mm thickness were suspended in 300 ml of H2SO4 solution of pH 4.0. The concentration of lead eluted from PZT was in the range from 0.2 to 0.8 ppm. It was found that both liquid phase formation by the addition of CuO and the substitution of Ba for Pb were effective to reduce the amount of lead that eluted. By fitting the leaching out curve with a classical equation, a master curve assuming no sampling effect was obtained. The lead concentration evaluated from the amount of lead that eluted from a commercial PZT plate to H2SO4 solution of pH 5.3 was almost the same as the limit in city water. It is concluded that PZT is not harmful to health and the environment and the amount of lead that eluted from PZT can be controlled by modifying PZT composition.

  4. An optimized method for elution of enteroviral RNA from a cellulose-based substrate.

    Science.gov (United States)

    Li, Yan; Yoshida, Hiromu; Wang, Lu; Tao, Zexin; Wang, Haiyan; Lin, Xiaojuan; Xu, Aiqiang

    2012-12-01

    The Flinders Technology Australia (FTA) Elute Card is a commercial product that facilitates the collection, transport, archiving and processing of nucleic acids from a wide variety of biological samples at room temperature. While the cards have been designed so that sterile/deionized water can elute DNA easily, they are not suitable for some less stable RNAs. This study was undertaken to determine the optimal conditions such as the buffer type, buffer pH and incubation temperature for the elution of enteroviral RNA from FTA Elute Cards prior to quantitative analysis using real-time PCR (qPCR) or consensus degenerate hybrid oligonucleotide primer VP1 RT-semi nested PCR (CODEHOP VP1 RT-snPCR). TE-1 (pH 8.0), rather than sterile water, was the best buffer for high efficiency elution of enteroviral RNA at 95°C. However, as the estimated recovery rate of viral RNA eluted from the cards averaged to be only 6.1%, enterovirus assays using FTA elution should be considered qualitative, especially at low virus titers, and therefore the results of the assay should be interpreted carefully. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Alendronate-Eluting Biphasic Calcium Phosphate (BCP Scaffolds Stimulate Osteogenic Differentiation

    Directory of Open Access Journals (Sweden)

    Sung Eun Kim

    2015-01-01

    Full Text Available Biphasic calcium phosphate (BCP scaffolds have been widely used in orthopedic and dental fields as osteoconductive bone substitutes. However, BCP scaffolds are not satisfactory for the stimulation of osteogenic differentiation and maturation. To enhance osteogenic differentiation, we prepared alendronate- (ALN- eluting BCP scaffolds. The coating of ALN on BCP scaffolds was confirmed by scanning electron microscopy (FE-SEM, energy-dispersive X-ray spectroscopy (EDS, and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR. An in vitro release study showed that release of ALN from ALN-eluting BCP scaffolds was sustained for up to 28 days. In vitro results revealed that MG-63 cells grown on ALN-eluting BCP scaffolds exhibited increased ALP activity and calcium deposition and upregulated gene expression of Runx2, ALP, OCN, and OPN compared with the BCP scaffold alone. Therefore, this study suggests that ALN-eluting BCP scaffolds have the potential to effectively stimulate osteogenic differentiation.

  6. Two-column sequential injection chromatography for fast isocratic separation of two analytes of greatly differing chemical properties.

    Science.gov (United States)

    Šatínský, Dalibor; Chocholouš, Petr; Válová, Olga; Hanusová, Lucia; Solich, Petr

    2013-09-30

    This paper deals with a novel approach to separate two analytes with different chemical properties and different lipophilicity. The newly described methodology is based on the two column system that was used for isocratic separation of two analytes with very different lipophilicity-dexamethasone and cinchocaine. Simultaneous separation of model compounds cinchocaine and dexamethasone was carried under the following conditions in two-column sequential injection chromatography system (2-C SIC). A 25×4.6 mm C-18 monolithic column was used in the first dimension for retention and separation of dexamethasone with mobile phase acetonitrile:water 30:70 (v/v), flow rate 0.9 mL min(-1) and consumption of 1.7 mL. A 10×4.6 mm C-18 monolithic column with 5×4.6 mm C-18 precolumn was used in the second dimension for retention and separation of cinchocaine using mobile phase acetonitrile:water 60:40 (v/v), flow rate 0.9 mL min(-1) and consumption 1.5 mL. Whole analysis time including both mobile phase's aspirations and both column separations was performed in less than 4 min. The method was fully validated and used for determination of cinchocaine and dexamethasone in pharmaceutical otic drops. The developed 2-C SIC method was compared with HPLC method under the isocratic conditions of separation on monolithic column (25×4.6 mm C-18). Spectrophotometric detection of both compounds was performed at wavelength 240 nm. System repeatability and method precision were found in the range (0.39-3.12%) for both compounds. Linearity of determination was evaluated in the range 50-500 μg mL(-1) and coefficients of determination were found to be r(2)=0.99912 for dexamethasone and r(2)=0.99969 for cinchocaine. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. A new method of analysis of peroxydisulfate using ion chromatography and its application to the simultaneous determination of peroxydisulfate and other common inorganic ions in a peroxydisulfate matrix.

    Science.gov (United States)

    Khan, Nymul E; Adewuyi, Yusuf G

    2011-01-21

    A new method for the determination of peroxydisulfate using ion chromatography has been developed. Elution of peroxydisulfate was effected by isocratic elution using 200 mM NaOH at 40°C. A modification of the method using gradient elution was able to simultaneously determine other common inorganic ions (nitrate, nitrite, sulfate and chloride) down to significantly low concentrations in a peroxydisulfate matrix. The relative standard deviations (RSD) were in the range of 0.5-5%, for peak areas and ion was 0.2 ppm and for the other ions were ≤2×10(-2) ppm. The calibration curves were linear with slope and intercepts close to 1 and 0, respectively. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. High-pressure liquid chromatography of trace elements: Determination of terbium in terbium doped gadolinium oxide sulphide phosphors

    International Nuclear Information System (INIS)

    Mazzucotelli, A.; Dadone, A.; Frache, R.; Baffi, F.; Genoa Univ.

    1982-01-01

    A detailed study of isocratic and gradient elution separations of lanthanides has been carried out. Analyses of industrially and scientifically interesting products such as luminescent phosphors have been carried out by gradient elution with DL-2-hydroxyisobutyric acid. The determination of small amounts of terbium in gadolinium oxide sulphide phosphors is described in which an HCl solution was eluted through a stainless steel column packed with microparticulate silica, with bonded cation-exchange groups. Complete separation of gadolinium and terbium is achieved. Detection is with a variable wavelength detector following post-column complex formation with 4-(2-pyridylazo)-resorcinol monosodium salt. Results obtained on test solutions show good reproducilbity and sensitivtiy and the method may be considered sufficiently reliable to be used in routine quality control procedures. (orig.)

  9. Development of Isocratic RP-HPLC Method for Separation and Quantification of L-Citrulline and L-Arginine in Watermelons

    Directory of Open Access Journals (Sweden)

    Rasdin Ridwan

    2018-01-01

    Full Text Available Watermelons (Citrullus lanatus are known to have sufficient amino acid content. In this study, watermelons grown and consumed in Malaysia were investigated for their amino acid content, L-citrulline and L-arginine, by the isocratic RP-HPLC method. Flesh and rind watermelons were juiced, and freeze-dried samples were used for separation and quantification of L-citrulline and L-arginine. Three different mobile phases, 0.7% H3P04, 0.1% H3P04, and 0.7% H3P04 : ACN (90 : 10, were tested on two different columns using Zorbax Eclipse XDB-C18 and Gemini C18 with a flow rate of 0.5 mL/min and a detection wavelength at 195 nm. Efficient separation with reproducible resolution of L-citrulline and L-arginine was achieved using 0.1% H3P04 on the Gemini C18 column. The method was validated and good linearity of L-citrulline and L-arginine was obtained with R2 = 0.9956, y=0.1664x+2.4142 and R2=0.9912, y=0.4100x+3.4850, respectively. L-citrulline content showed the highest concentration in red watermelon of flesh and rind juice extract (43.81 mg/g and 45.02 mg/g, whereas L-arginine concentration was lower than L-citrulline, ranging from 3.39 to 11.14 mg/g. The isocratic RP-HPLC method with 0.1% H3P04 on the Gemini C18 column proved to be efficient for separation and quantification of L-citrulline and L-arginine in watermelons.

  10. Elution behavior of heavy metals from cement solidified products of incinerated ash waste - 59102

    International Nuclear Information System (INIS)

    Meguro, Yoshihiro; Kawato, Yoshimi; Nakayama, Takuya; Tomioka, Osamu; Mitsuda, Motoyuki

    2012-01-01

    A method, in which incinerated ash is solidified with a cement material, has been developed to dispose radioactive incinerated ash waste. In order to bury the solidified product, it is required that elution of hazardous heavy metals included in the ash from the solidified products is inhibited. In this study, the elution behavior of the heavy metals from the synthetic solidified products, which included Pb(II), Cd(II), and Cr(VI) and were prepared using ordinary portland cement (OPC), blast furnace slag cement (BFS), or a cement material that showed low alkalinity (LA-Cement), was investigated. Several chemicals and materials were added as additive agents to prevent the elution of the heavy metals. When OPC was used, Cd elution was inhibited, but Pb and Cr were not enough even using the additive agent examined. FeSO 4 and Na 2 S additive agents worked effective to inhibit elution of Cr. When BFS was used, the elution of Pb, Cd and Cr was inhibited for the all products prepared. In the case of LA-Cement, the elution of Pb and Cd was inhibited for the all products, but only the product that was added FeSO 4 showed good result of the elution of Cr. (authors)

  11. A fast isocratic liquid chromatography method for the quantification of xanthophylls and their stereoisomers.

    Science.gov (United States)

    Nimalaratne, Chamila; Lopes-Lutz, Daise; Schieber, Andreas; Wu, Jianping

    2015-12-01

    A fast isocratic liquid chromatography method was developed for the simultaneous quantification of eight xanthophylls (13-Z-lutein, 13'-Z-lutein, 13-Z-zeaxanthin, all-E-lutein, all-E-zeaxanthin, all-E-canthaxanthin, all-E-β-apo-8'-carotenoic acid ethyl ester and all-E-β-apo-8'-carotenal) within 12 min, compared to 90 min by the conventional high-performance liquid chromatography method. The separation was achieved on a YMC C30 reversed-phase column (100 mm x 2.0 mm; 3 μm) operated at 20°C using a methanol/tert-butyl methyl ether/water solvent system at a flow rate of 0.8 mL/min. The method was successfully applied to quantify lutein and zeaxanthin stereoisomers in egg yolk, raw and cooked spinach, and a dietary supplement. The method can be used for the rapid analysis of xanthophyll isomers in different food products and for quality control purposes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Paclitaxel-eluting versus sirolimus-eluting stents in diabetes mellitus: a report from the National Heart, Lung, and Blood Institute Dynamic Registry.

    Science.gov (United States)

    Wolf, William M; Vlachos, Helen A; Marroquin, Oscar C; Lee, Joon S; Smith, Conrad; Anderson, William D; Schindler, John T; Holper, Elizabeth M; Abbott, J Dawn; Williams, David O; Laskey, Warren K; Kip, Kevin E; Kelsey, Sheryl F; Mulukutla, Suresh R

    2010-02-01

    Diabetes is a powerful predictor of adverse events in patients undergoing percutaneous coronary intervention. Drug-eluting stents reduce restenosis rates compared with bare metal stents; however, controversy remains regarding which drug-eluting stents provides greater benefit in patients with diabetes. Accordingly, we compared the safety and efficacy of sirolimus-eluting stents (SES) with paclitaxel-eluting stents (PES) among diabetic patients in a contemporary registry. Using the National Heart, Lung, and Blood Institute Dynamic Registry, we evaluated 2-year outcomes of diabetic patients undergoing percutaneous coronary interventions with SES (n=677) and PES (n=328). Clinical and demographic characteristics, including age, body mass index, insulin use, left ventricular function, and aspirin/clopidogrel use postprocedure, did not differ significantly between the groups except that PES-treated patients had a greater frequency of hypertension and hyperlipidemia. At the 2-year follow-up, no significant differences were observed between PES and SES with regard to safety or efficacy end points. PES- and SES-treated patients had similar rates of death (10.7% versus 8.2%, P=0.20), death and myocardial infarction (14.9% versus 13.6%, P=0.55), repeat revascularization (14.8% versus 17.8%, P=0.36), and stent thrombosis (1.3% versus 1.3%, P=0.95). After adjustment, no significant differences between the 2 stent types in any outcome were observed. PES and SES are equally efficacious and have similar safety profiles in diabetic patients undergoing percutaneous coronary interventions in clinical practice.

  13. Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.

    Science.gov (United States)

    Yazdani, Saami K; Sheehy, Alexander; Pacetti, Stephen; Rittlemeyer, Brandon; Kolodgie, Frank D; Virmani, Renu

    2016-10-01

    Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo. © 2016, Wiley Periodicals, Inc.

  14. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    BACKGROUND: In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery...... disease who were receiving routine clinical care with no direct follow-up. METHODS: We did a single-blind, all-comer superiority trial in adult patients with chronic stable coronary artery disease or acute coronary syndromes, and at least one target lesion. Patients were treated at one of five...... Danish administrative and health-care registries. The primary endpoint was a composite of major adverse cardiac events within 9 months: cardiac death, myocardial infarction, and target vessel revascularisation. Intention-to-treat analyses were done at 9-month and 18-month follow-up. This trial...

  15. A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial

    NARCIS (Netherlands)

    de Winter, Robbert J.; Katagiri, Yuki; Asano, Taku; Milewski, Krzysztof P.; Lurz, Philipp; Buszman, Pawel; Jessurun, Gillian A. J.; Koch, Karel T.; Troquay, Roland P. T.; Hamer, Bas J. B.; Ophuis, Ton Oude; Wöhrle, Jochen; Wyderka, Rafał; Cayla, Guillaume; Hofma, Sjoerd H.; Levesque, Sébastien; Żurakowski, Aleksander; Fischer, Dieter; Kośmider, Maciej; Goube, Pascal; Arkenbout, E. Karin; Noutsias, Michel; Ferrari, Markus W.; Onuma, Yoshinobu; Wijns, William; Serruys, Patrick W.

    2018-01-01

    Background MiStent is a drug-eluting stent with a fully absorbable polymer coating containing and embedding a microcrystalline form of sirolimus into the vessel wall. It was developed to overcome the limitation of current durable polymer drug-eluting stents eluting amorphous sirolimus. The clinical

  16. The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Hiroshi Fujita

    2014-12-01

    Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.

  17. Sirolimus-eluting versus bare-metal stent implantation in patients with ostial lesions

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Kelbæk, Henning; Kløvgaard, Lene

    2010-01-01

    To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries.......To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries....

  18. Elution of Artificial Sputum from Swab by Rotating Magnetic Field-Induced Mechanical Impingement

    Directory of Open Access Journals (Sweden)

    Shubham Banik

    2017-12-01

    Full Text Available Cotton-tipped applicator swabs are used as a collection device for many biological samples and its complete elution is a desired step for clinical and forensic diagnostics. Swabs are used to collect infectious body fluids, where the concentration of pathogens can range from 1 × 104 CFU/mL (colony forming units/mL in respiratory-tract infections and 1 × 105 in urinary-tract infections, to up to 1 × 109 CFU/mL in salivary samples. These samples are then eluted and lysed, prior to DNA (De-oxy Ribonucleic Acid analysis. The recovery of micro-organisms from a matrix of swab fibres depends on the nature of the body fluid, the type of the swab fibres, and the process of elution. Various methods to elute samples from swab include chemical digestion of fibres (~20% recovery, centrifugation (~58% recovery, piezoelectric vibration, or pressurized fluid-flow (~60% recovery. This study reports a magnetically-actuated physical impingement method for elution and recovery of artificial sputum samples from cotton fibres. A device has been fabricated to induce a rotating magnetic field on smaller magnetic particles in a vial that strikes the swab within a confined gap. Elution from the swab in this device was characterized using 2% Methyl cellulose in deionised water, loaded with fluorescent-tagged polystyrene beads and E. coli at various concentrations. The recovery efficiency was found to increase with both rotational speed and elution time, but plateaus after 400 RPM (Revolutions per minute and 120 s, respectively. At a higher concentration of polystyrene beads (5 × 108 particles/mL, a maximum recovery of ~85% was achieved. With lower concentration, (1 × 105 particles/mL the maximum efficiency (~92.8% was found to be almost twice of passive elution (46.7%. In the case of E. coli, the corresponding recovery efficiency at 3.35 × 105 CFU/mL is 90.4% at 500 RPM and 120 s. This elution method is expected to have a wide applicability in clinical diagnostics.

  19. Safety and efficacy of everolimus-eluting stents compared with first-generation drug-eluting stents in patients undergoing primary percutaneous coronary intervention

    Energy Technology Data Exchange (ETDEWEB)

    Escárcega, Ricardo O.; Baker, Nevin C.; Magalhaes, Marco A.; Lipinski, Michael J.; Minha, Sa’ar; Torguson, Rebecca; Satler, Lowell F.; Pichard, Augusto D.; Suddath, William O.; Waksman, Ron, E-mail: ron.waksman@medstar.net

    2014-09-15

    Objective: To assess the safety and efficacy everolimus-eluting stents (EES) compared with first-generation drug-eluting stents (DES) in patients with acute myocardial infarction (MI) undergoing primary percutaneous coronary intervention (PCI). Background: EES have been associated with improved clinical outcomes compared to paclitaxel-eluting stents (PES) and with similar outcomes compared to sirolimus-eluting stents (SES). Methods: A total of 520 patients who presented with ST-elevation myocardial infarction (STEMI) from 2003 to 2013, who underwent primary PCI with DES, were retrospectively analyzed. Of these, 247 received SES, 136 PES, and 137 EES. Patients were followed up to 2 years for major adverse cardiac events (MACE). Univariate and multivariate models detected correlates to outcome. Results: EES implantation, compared with PES and SES, resulted in comparable rates of MACE (8.8% vs. 16.2%, p = 0.06 and 8.8% vs. 12.6%, respectively, p = 0.26), stent thrombosis, MI, and target lesion revascularization. Patients who received EES had lower rates of all-cause mortality (3.7% vs. 12.6% vs. 9.4%, p = 0.03) at 1-year follow up. However, in the univariate and multivariate analyses, stent type was not independently associated with the primary outcome or with all-cause mortality. Diabetes mellitus and number of stents implanted were independently associated with the primary outcome. Conclusion: While EES seem to be associated with better outcome when compared to PES, the main correlates of STEMI patients are the presence of diabetes and number of stents implanted, and not the type of stent used for intervention.

  20. Chromatographic analyses of fatty acid methyl esters by HPLC-UV and GC-FID

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Myller S.; Pinho, David M.M.; Suarez, Paulo A.Z., E-mail: psuarez@unb.br [Laboratorio de Materiais e Combustiveis, Instituto de Quimica, Universidade de Brasilia, DF (Brazil); Mendonca, Marcio A. [Faculdade de Agronomia e Medicina Veterinaria, Universidade de Brasilia, DF (Brazil); Resck, Ines S. [Laboratorio de Ressonancia Magnetica Nuclear, Universidade de Brasilia, DF (Brazil)

    2012-04-15

    An analytical method using high performance liquid chromatography with UV detection (HPLC-UV) (method A) was used for simultaneous determination of total amounts of triacylglycerides, diacylglycerides, monoacylglycerides and fatty acid methyl esters in alcoholysis of different oil (cotton, canola, sunflower, corn and soybean) samples. Analyses were carried out at 40 deg C for 20 min using a gradient of methanol (MeOH) and 2-propanol-hexane 5:4 (v/v) (PrHex): 100% of MeOH in 0 min, 50% of MeOH and 50% of PrHex in 10 min maintained with isocratic elution for 10 min. Another HPLC-UV method (method B) with acetonitrile isocratic elution for 34 min was used to determine the fatty acid composition of oils analyzing their methyl ester derivatives. Contents were determined with satisfactory repeatability (relative standard deviation, RSD < 3%), linearity (r{sup 2} > 0.99) and sensitivity (limit of quantification). Method B was compared with an official gas chromatographic method with flame ionization detection (GC-FID) from American Oil Chemists' Society (AOCS) in the determination of fatty acid methyl esters (FAME) in biodiesel real samples. (author)

  1. Analysis by high-performance liquid chromatography of radioactively labeled carbohydrate components of proteoglycans

    International Nuclear Information System (INIS)

    Lohmander, L.S.

    1986-01-01

    Methods were developed for the separation of radioactively labeled carbohydrate components of proteoglycans by isocratic ion-moderated partition HPLC. Neutral sugars were separated after hydrolysis in trifluoroacetic acid with baseline separation between glucose, xylose, galactose, fucose, and mannose. N-Acetylneuraminic acid, N-acetylated hexosamines, glucose, galactose, and xylitol were likewise well separated from each other under isocratic elution conditions. Glucuronic acid, iduronic acid, and their lactones were separated after hydrolysis in formic acid and sulfuric acid. Glucosamine, galactosamine, galactosaminitol, and glucosaminitol were separated by HPLC on a cation exchanger with neutral buffer after hydrolysis in hydrochloric acid. THe separation techniques also proved useful in fractionation of exoglycosidase digests of O- and N-linked oligosaccharides. Separations of aldoses, hexosamines, and uronic acids were adapted to sensitive photometric detection

  2. Studies of post-elution concentration of 99m-Tc eluted from a gel type chromatographic generator

    International Nuclear Information System (INIS)

    Suzuki, Katia N.; Osso Junior, Joao Alberto

    2007-01-01

    The radiopharmaceuticals most used in Diagnostic Nuclear Medicine are those labeled with the metastable technetium ( 99m Tc) due to its ideal physical properties of decay (t 1/2 6.01 h, Eγ 140 keV), low cost and availability facilitated through the commercial generator 99 Mo / 99m Tc. This radionuclide is formed by the β - decay of 99 Mo adsorbed on an alumina column of the generator and collected in the form of sodium pertechnetate (Na 99m TcO 4 ) by elution with saline solution (0.9%). The Radiopharmacy Center (CR) of the IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with 99 Mo produced by 98 Mo(n, γ) 99 Mo reaction that occurs in IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 ml with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (34 mCi) / ml. The fission generator gives a higher radioactive concentration around 1850 MBq (69 mCi) / ml. The aim of this work is to study a system of post-elution concentration using ion exchange cartridges in tandem (cation - anion) for the attainment of a high enough radioactive concentration to meet the demand of market, with a proved quality. This system of concentration will be made based in the technique of solid phase extraction (SPE) using commercial cartridges of extraction, which contains the solid phase and eluent saline solution (0.9%). As the eluent results of this system used in the gel generator of MoZr will be compared with the fission generator currently produced by IPEN-CNEN/SP. (author)

  3. Elution of Monomers from Provisional Composite Materials

    Directory of Open Access Journals (Sweden)

    Simon Daniel Schulz

    2015-01-01

    Full Text Available The aim of this study was to evaluate the elution of substances from different materials used for the manufacturing of temporary indirect restorations, after storage in saliva and ethanol 75%. 10 samples of three chemically cured materials (Protemp 3 Garant, Systemp.c&b, and Trim and one light-cured material (Clip F were stored in saliva and ethanol 75% for 24 h, 7, and days 28 days. From the storage media at each time period, samples were prepared and analysed by LC-MS/MS, in order to access the elution of monomers. The results differed among the materials (P ≤ 0.05. No monomers were detected in the samples of Protemp 3 Garant and Clip F. Substances were detected only in ethanol samples of Systemp.c&b and Trim. The amount of BisGMA, TEGDMA, and UDMA 2 released from Systemp.c&b was higher compared to Trim. Storage time affected the release of substances (P ≤ 0.05. The highest release was observed within the first 24 h. It can be concluded that provisional resin composite materials do not show high release of monomers and this release is material dependent. However, the detection of additional peaks during the analysis, suggesting the formation of by-products of the eluted substances, may not be in favour of these materials with respect to their toxicity.

  4. Rationale and Design of a Randomized Clinical Comparison of Everolimus-Eluting (Xience V/Promus) and Sirolimus-Eluting (Cypher Select+) Coronary Stents in Unselected Patients with Coronary Heart Disease

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Tilsted, Hans Henrik

    2010-01-01

    with Clinical Outcome (SORT OUT) IV trial was designed as a prospective, multi-center, open-label, all-comer, two-arm, randomized, non-inferiority study comparing the everolimus-eluting stent with the sirolimus-eluting stent in the treatment of atherosclerotic coronary artery lesions. Based on a non...

  5. Enhanced performance of magnesium alloy for drug-eluting vascular scaffold application

    Science.gov (United States)

    Dong, Hongzhou; Li, Daikun; Mao, Daoyong; Bai, Ningning; Chen, Yashi; Li, Qing

    2018-03-01

    Bio-absorbable magnesium alloys drug-eluting vascular scaffold was developed to resolve the defect of permanent metal and drug-eluting stents, most notably a chronic vessel wall inflammation and the risk of stent thrombosis. Nevertheless, violent chemical reaction and rapid degradation under physiological conditions limits their application. Furthermore, multifunctional drug-eluting stents which could reduce the formation of thrombus and repair the damaged vessels need more attention to fundamentally cure the coronary artery disease. Herein, a drug delivery system (Mg/MgO/PLA-FA) which can realize sustainable release of ferulaic acid was designed via anodic oxidation process and dip coating process. Electrochemical tests and immersion experiments showed that the superior anticorrosion behavior, it is due to the dense MgO-PLA composite layer. The released ferulaic acid can effectively decrease platelets adhesion and aggregation during the early stage of implantation. Besides, hemolysis tests showed that the composite coatings endowed the Mg alloy with a low hemolysis ratio. The Mg/MgO/PLA-FA composite materials may be appropriate for applications on biodegradable Mg alloys drug-eluting stents.

  6. Kuldkaru elutöö eest / Endel Link

    Index Scriptorium Estoniae

    Link, Endel

    2001-01-01

    Ameerika näitleja Kirk Douglas (1916), kellele seekordsel Berlinalel antakse elutöö eest Kuldkaru. Austamisõhtul näidatakse teda Stanley Kubricku kaua keelu all olnud filmis "Tee kuulsusele " ("Paths of Glory") : 1957

  7. Safety and efficacy of limus-eluting stents and balloon angioplasty for sirolimus-eluting in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Kitabata, Hironori; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-03-15

    Objectives: The aim of this study was to compare the safety and efficacy of everolimus-eluting stent (EES), sirolimus-eluting stent (SES), and plain old balloon angioplasty (POBA) for the treatment of SES in-stent restenosis (S-ISR). Background: The optimal treatment for drug-eluting in-stent restenosis remains controversial. Methods: The study cohort comprised 310 consecutive patients (444 lesions) who presented with S-ISR to our institution and underwent treatment with EES (43 patients), SES (102), or POBA (165). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac event (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors for coronary artery disease except for smoking. The 1-year analyzed clinical parameters were similar in the three groups: MACE (EES = 14%, SES = 18%, POBA = 20%; p = 0.65), death (EES = 2.3%, SES = 6.2%, POBA = 6.1%; p = 0.61), MI (EES = 4.8%, SES = 2.1%, POBA = 2.5%; p = 0.69), TLR (EES = 11.9%, SES = 12.1%, POBA = 24%; p = 0.78), and TVR (EES = 11.9%, SES = 24.8%, POBA = 22.2%; p = 0.23). There were no cases of definite ST. MACE-free rate was significantly lower in patients with recurrent in-stent restenosis (log-rank p = 0.006). Presentation with acute MI, number of treated lesions and a previous history of MI were found to be independent predictors of MACE. Conclusions: In patients presenting with S-ISR, treatment with implantation of an EES, SES, or POBA is associated with similar clinical outcomes. Patients presenting with recurrent ISR may have a poorer clinical outcome.

  8. A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial.

    Science.gov (United States)

    de Winter, Robbert J; Katagiri, Yuki; Asano, Taku; Milewski, Krzysztof P; Lurz, Philipp; Buszman, Pawel; Jessurun, Gillian A J; Koch, Karel T; Troquay, Roland P T; Hamer, Bas J B; Ophuis, Ton Oude; Wöhrle, Jochen; Wyderka, Rafał; Cayla, Guillaume; Hofma, Sjoerd H; Levesque, Sébastien; Żurakowski, Aleksander; Fischer, Dieter; Kośmider, Maciej; Goube, Pascal; Arkenbout, E Karin; Noutsias, Michel; Ferrari, Markus W; Onuma, Yoshinobu; Wijns, William; Serruys, Patrick W

    2018-02-03

    MiStent is a drug-eluting stent with a fully absorbable polymer coating containing and embedding a microcrystalline form of sirolimus into the vessel wall. It was developed to overcome the limitation of current durable polymer drug-eluting stents eluting amorphous sirolimus. The clinical effect of MiStent sirolimus-eluting stent compared with a durable polymer drug-eluting stents has not been investigated in a large randomised trial in an all-comer population. We did a randomised, single-blind, multicentre, phase 3 study (DESSOLVE III) at 20 hospitals in Germany, France, Netherlands, and Poland. Eligible participants were any patients aged at least 18 years who underwent percutaneous coronary intervention in a lesion and had a reference vessel diameter of 2·50-3·75 mm. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting bioresorbable polymer stent (MiStent) or an everolimus-eluting durable polymer stent (Xience). Randomisation was done by local investigators via web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint (DOCE)-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between the groups at 12 months after the procedure assessed by intention-to-treat. A margin of 4·0% was defined for non-inferiority of the MiStent group compared with the Xience group. All participants were included in the safety analyses. This trial is registered with ClinicalTrials.gov, number NCT02385279. Between March 20, and Dec 3, 2015, we randomly assigned 1398 patients with 2030 lesions; 703 patients with 1037 lesions were assigned to MiStent, of whom 697 received the index procedure, and 695 patients with 993 lesions were asssigned to Xience, of whom 690 received the index procedure. At 12 months, the primary endpoint had occurred in 40 patients (5·8%) in the sirolimus-eluting stent group and in 45

  9. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.

    Science.gov (United States)

    Serruys, Patrick W; Farooq, Vasim; Kalesan, Bindu; de Vries, Ton; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Eberli, Franz; Wijns, William; Morice, Marie Claude; Di Mario, Carlo; Corti, Roberto; Antoni, Diethmar; Sohn, Hae Y; Eerdmans, Pedro; Rademaker-Havinga, Tessa; van Es, Gerrit-Anne; Meier, Bernhard; Jüni, Peter; Windecker, Stephan

    2013-08-01

    This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority 1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Application of Multi-Analyte Methods for Pesticide Formulations

    Energy Technology Data Exchange (ETDEWEB)

    Lantos, J.; Virtics, I. [Plant Protection & Soil Conservation Service of Szabolcs-Szatmár-Bereg County, Nyíregyháza (Hungary)

    2009-07-15

    The application of multi-analyte methods for pesticide formulations by GC analysis is discussed. HPLC was used to determine active ingredients. HPLC elution sequences were related to individual n-octanol/water partition coefficients. Real laboratory data are presented and evaluated with regard to validation requirements. The retention time data of pesticides on different HPLC columns under gradient and isocratic conditions are compared to illustrate the applicability of the methodologies. (author)

  11. Studies of post-elution concentration of {sup 99m}-Tc eluted from a gel type chromatographic generator

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Katia N.; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: norisuzuki6@yahoo.com.br; jaosso@ipen.br

    2007-07-01

    The radiopharmaceuticals most used in Diagnostic Nuclear Medicine are those labeled with the metastable technetium ({sup 99m}Tc) due to its ideal physical properties of decay (t{sub 1/2} 6.01 h, E{gamma} 140 keV), low cost and availability facilitated through the commercial generator {sup 99}Mo /{sup 99m}Tc. This radionuclide is formed by the {beta}{sup -} decay of {sup 99}Mo adsorbed on an alumina column of the generator and collected in the form of sodium pertechnetate (Na{sup 99m}TcO{sub 4}) by elution with saline solution (0.9%). The Radiopharmacy Center (CR) of the IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with {sup 99}Mo produced by {sup 98}Mo(n, {gamma}){sup 99}Mo reaction that occurs in IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 ml with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (34 mCi) / ml. The fission generator gives a higher radioactive concentration around 1850 MBq (69 mCi) / ml. The aim of this work is to study a system of post-elution concentration using ion exchange cartridges in tandem (cation - anion) for the attainment of a high enough radioactive concentration to meet the demand of market, with a proved quality. This system of concentration will be made based in the technique of solid phase extraction (SPE) using commercial cartridges of extraction, which contains the solid phase and eluent saline solution (0.9%). As the eluent results of this system used in the gel generator of MoZr will be compared with the fission generator currently produced by IPEN-CNEN/SP. (author)

  12. Boron removal from aqueous solutions by ion-exchange resin: Column sorption-elution studies

    International Nuclear Information System (INIS)

    Koese, T. Ennil; Oztuerk, Nese

    2008-01-01

    A column sorption-elution study was carried out by using a strong base anion-exchange resin (Dowex 2 x 8) for the removal of boron from aqueous solutions. The breakthrough curve was obtained as a function of feed flow rate and the total and breakthrough capacity values of the resin were calculated. The boron on the resin was quantitatively eluted with 0.5 M HCl solution at different flow rates. Three consecutive sorption-elution-washing-regeneration-washing cycles were applied to the resin in order to investigate the reusability of the ion-exchange resin. Total capacity values remained almost the same after three sorption-elution-regeneration cycles. The Thomas and the Yoon-Nelson models were applied to experimental data to predict the breakthrough curves and to determine the characteristic column parameters required for process design. The results proved that the models would describe the breakthrough curves well

  13. Long-term Outcomes of Paclitaxel-Eluting Versus Sirolimus-Eluting Stent for Percutaneous Coronary Intervention: A Meta-Analysis

    International Nuclear Information System (INIS)

    Kong, J.; Liu, P.; Fan, X.; Wen, J.; Zhang, J.; Zhen, Y.; Li, J.; Cui, Y.; Zheng, X.; Ye, Z.

    2017-01-01

    The relative long-term efficacy and safety of sirolimus-eluting stents (SES) compared with paclitaxel-eluting stents (PES) in multiple comparative studies remains controversial. This report evaluates 29 randomized trials with 18,379 patients in whom long-term (more than 1 year) outcomes were evaluated. The primary outcomes were target lesion revascularization (TLR) and the secondary end points were death, cardiac death, myocardial infarction (MI), major adverse cardiac events (MACEs), target vessel revascularization (TVR)and stent thrombosis (ST). In comparison with PES, SES significantly reduced the long-term risk of TLR (RR=0.68; 95% CI=0.57 to 0.80, p<0.001), TVR (RR=0.69; 95% CI= 0.60 to 0.79, p<0.001) and MACE (RR=0.82; 95% CI= 0.77 to 0.88, p<0.001), while there were no significant difference with respect to death, cardiac death, MI and ST between the two groups. SES performance was significantly better for reducing the former three outcomes and comparable for the majority of the secondary end points when compared against PES. (author)

  14. Selective elution of HLA antigens and beta 2-microglobulin from human platelets by chloroquine diphosphate

    International Nuclear Information System (INIS)

    Kao, K.J.

    1988-01-01

    To determine whether chloroquine can specifically elute HLA antigens and beta 2-microglobulin (beta 2-M) from the platelet surface, quantitative immunofluorescence flow cytometry and monoclonal antibodies were used to show that HLA antigens and beta 2-M were proportionally eluted from the platelet surface without affecting the membrane glycoproteins IIb and IIIa. Second, an autoradiogram of electrophoresed I-125-labeled platelets showed that only beta 2-M but not other I-125-labeled membrane proteins could be eluted. Although HLA antigens were poorly labeled by I-125 and could not be detected on the autoradiogram, the eluted HLA antigens could be detected by anti-HLA monoclonal antibody and immunoblotting techniques. No loss of plasma membrane integrity was observed by transmission electron microscopy after chloroquine treatment of platelets. The results indicate that chloroquine selectively elutes HLA antigens and their noncovalently associated beta 2-M without affecting other integral platelet membrane proteins

  15. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; Otaegui, Imanol; Masotti, Mónica; Zueco, Javier; Veláquez, Maite; Sanchís, Juan; García-Touchard, Arturo; Lázaro-García, Rosa; Moreu, José; Bethencourt, Armando; Cuesta, Javier; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-06-27

    The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p 1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent] [RIBS V]; NCT01239953). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Evaluation of differences between dual salt-pH gradient elution and mono gradient elution using a thermodynamic model: Simultaneous separation of six monoclonal antibody charge and size variants on preparative-scale ion exchange chromatographic resin.

    Science.gov (United States)

    Lee, Yi Feng; Jöhnck, Matthias; Frech, Christian

    2018-02-21

    The efficiencies of mono gradient elution and dual salt-pH gradient elution for separation of six mAb charge and size variants on a preparative-scale ion exchange chromatographic resin are compared in this study. Results showed that opposite dual salt-pH gradient elution with increasing pH gradient and simultaneously decreasing salt gradient is best suited for the separation of these mAb charge and size variants on Eshmuno ® CPX. Besides giving high binding capacity, this type of opposite dual salt-pH gradient also provides better resolved mAb variant peaks and lower conductivity in the elution pools compared to single pH or salt gradients. To have a mechanistic understanding of the differences in mAb variants retention behaviors of mono pH gradient, parallel dual salt-pH gradient, and opposite dual salt-pH gradient, a linear gradient elution model was used. After determining the model parameters using the linear gradient elution model, 2D plots were used to show the pH and salt dependencies of the reciprocals of distribution coefficient, equilibrium constant, and effective ionic capacity of the mAb variants in these gradient elution systems. Comparison of the 2D plots indicated that the advantage of opposite dual salt-pH gradient system with increasing pH gradient and simultaneously decreasing salt gradient is the noncontinuous increased acceleration of protein migration. Furthermore, the fitted model parameters can be used for the prediction and optimization of mAb variants separation in dual salt-pH gradient and step elution. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 2018. © 2018 American Institute of Chemical Engineers.

  17. Innovative Elution Processes for Recovering Uranium and Transition Metals from Amidoxime-based Adsorbents

    Energy Technology Data Exchange (ETDEWEB)

    Wai, Chien M. [Univ. of Idaho, Moscow, ID (United States). Dept. of Chemistry

    2017-04-18

    Amidoxime-based polymer fibers are considered one of the most promising materials for sequestering uranium from seawater. The high-surface-area polymer fibers containing amidoxime and carboxylate groups synthesized by Oak Ridge National Lab (ORNL-AF1) show very high uranium adsorption capacities known in the literature. Effective elution of uranium and repeated use of the adsorbent are important factors affecting the cost of producing uranium from seawater using this material. Traditional acid leaching of uranium followed by KOH conditioning of the fiber causes chemical changes and physical damage to the ORNL-AF1 adsorbent. Two alkaline solution leaching methods were developed by this project, one uses a highly concentrated (3 M) potassium bicarbonate solution at pH 8.3 and 40 °C; the other uses a mixture of sodium carbonate and hydrogen peroxide at pH 10.4. Both elution methods do not require KOH conditioning prior to reusing the fiber adsorbent. The conditions of eluting uranium from the amidoxime-based adsorbent using these alkaline solutions are confirmed by thermodynamic calculations. The bicarbonate elution method is selective for uranium recovery compared to other elution methods and causes no chemical change to the fiber material based on FTIR spectroscopy

  18. Randomised comparison of a bioresorbable everolimus-eluting scaffold with a metallic everolimus-eluting stent for ischaemic heart disease caused by de novo native coronary artery lesions

    DEFF Research Database (Denmark)

    Chevalier, Bernard; Onuma, Yoshinobu; van Boven, Ad J

    2016-01-01

    AIMS: The one-year randomised data of the ABSORB II trial showed that the everolimus-eluting bioresorbable scaffold and the everolimus-eluting metallic stent were comparable for the composite secondary clinical outcomes of patient-oriented composite endpoint (PoCE) and device-oriented composite...... Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (XIENCE; Abbott Vascular). The trial enrolled 501 patients. Clinical follow-up at two years was available in 320 patients in the Absorb BVS arm and 160 patients in the XIENCE arm. At two years, the PoCE for the Absorb and XIENCE arms......-six percent and 34% of patients remained on DAPT at two years, respectively. Ninety-two percent of patients in both arms remained on aspirin. CONCLUSIONS: Two-year clinical results demonstrate sustained low rates of PoCE, MACE, DoCE and TVF with the Absorb BVS as compared to the XIENCE stent....

  19. Involvement of COX-2 in nickel elution from a wire implanted subcutaneously in mice.

    Science.gov (United States)

    Sato, Taiki; Kishimoto, Yu; Asakawa, Sanki; Mizuno, Natsumi; Hiratsuka, Masahiro; Hirasawa, Noriyasu

    2016-07-01

    Many types of medical alloys include nickel (Ni), and the elution of Ni ions from these materials causes toxicities and inflammation. We have previously reported that inflammation enhances Ni elution, although the molecular mechanisms underlying this effect remain unclear. In this study, we investigated how inflammatory responses enhanced Ni elution in a wire-implantation mouse model. Subcutaneous implantation of Ni wire induced the expression of cyclooxygenase-2 (COX-2) and microsomal prostaglandin E synthase-1 (mPGES-1) mRNA in the surrounding tissues. Immunostaining analysis showed that cells expressing COX-2 were mainly fibroblast-like cells 8h after implantation of a Ni wire, but were mainly infiltrated leukocytes at 24h. NiCl2 induced the expression of COX-2 mRNA in primary fibroblasts, neutrophils, RAW 264 cells, and THP-1 cells, indicating that Ni ions can induce COX-2 expression in various types of cells. The elution of Ni ions from the implanted Ni wire at 8h was reduced by dexamethasone (Dex), indomethacin (Ind), or celecoxib (Cel) treatment. Ni wire implantation induced an increase in mRNA levels for anaerobic glycolytic pathway components glucose transporter 1 (GLUT1), hexokinase 2 (HK2), lactate dehydrogenase A (LDHA), and monocarboxylate transporter 4 (MCT4); the expression of these genes was also inhibited by Dex, Ind, and Cel. In primary fibroblasts, the expression of these mRNAs and the production of lactate were induced by NiCl2 and further potentiated by PGE2. Furthermore, Ni wire-induced infiltration of inflammatory leukocytes was significantly reduced by Dex, Ind, or Cel. Depletion of neutrophils with a specific antibody caused reduction of both leukocyte infiltration and Ni elution. These results indicate that Ni ions eluted from wire induced COX-2 expression, which further promoted elution of Ni ions by increasing lactate production and leukocyte infiltration. Since COX inhibitors and Dex reduced the elution of Ni ions, these drugs may be

  20. Drug-eluting stents studies in mice: Do we need atherosclerosis to study restenosis?

    NARCIS (Netherlands)

    Pires, N.M.M.; Jukema, J.W.; Daemen, M.J.A.P.; Quax, P.H.A.

    2006-01-01

    In 2001, the first human study with drug-eluting stents (DES) was published showing a nearly complete abolition of restenosis by using a sirolimus-eluting stent. This success was very encouraging to test new compounds in combination with the DES platform. Nevertheless, several other anti-restenotic

  1. Application of retention modelling to the simulation of separation of organic anions in suppressed ion chromatography.

    Science.gov (United States)

    Zakaria, Philip; Dicinoski, Greg W; Ng, Boon Khing; Shellie, Robert A; Hanna-Brown, Melissa; Haddad, Paul R

    2009-09-18

    The ion-exchange separation of organic anions of varying molecular mass has been demonstrated using ion chromatography with isocratic, gradient and multi-step eluent profiles on commercially available columns with UV detection. A retention model derived previously for inorganic ions and based solely on electrostatic interactions between the analytes and the stationary phase was applied. This model was found to accurately describe the observed elution of all the anions under isocratic, gradient and multi-step eluent conditions. Hydrophobic interactions, although likely to be present to varying degrees, did not limit the applicability of the ion-exchange retention model. Various instrumental configurations were investigated to overcome problems associated with the use of organic modifiers in the eluent which caused compatibility issues with the electrolytically derived, and subsequently suppressed, eluent. The preferred configuration allowed the organic modifier stream to bypass the eluent generator, followed by subsequent mixing before entering the injection valve and column. Accurate elution prediction was achieved even when using 5-step eluent profiles with errors in retention time generally being less than 1% relative standard deviation (RSD) and all being less than 5% RSD. Peak widths for linear gradient separations were also modelled and showed good agreement with experimentally determined values.

  2. Simultaneous determination of some water-soluble vitamins and preservatives in multivitamin syrup by validated stability-indicating high-performance liquid chromatography method.

    Science.gov (United States)

    Vidović, Stojanka; Stojanović, Biljana; Veljković, Jelena; Prazić-Arsić, Ljiljana; Roglić, Goran; Manojlović, Dragan

    2008-08-22

    HPLC stability-indicating method has been developed for the simultaneous determination of some water-soluble vitamins (ascorbic acid, thiamine hydrochloride, riboflavin-5'-phosphate sodium, pyridoxine hydrochloride, nicotinamide, D(+)-panthenol) and two preservatives (methylparaben and sodium benzoate) in multivitamin syrup preparation. Water-soluble vitamins, preservatives and their degradants were separated on Zorbax SB-Aq (C(18)) (250 mm x 4.6 mm, 5 microm) column at an ambient temperature. Combined isocratic and gradient elution was performed with a mobile phase consisting of 0.0125 M hexane-1-sulfonic acid sodium salt in 0.1% (m/v) o-phosphoric acid, pH 2.4-2.5 (solvent A) and acetonitrile (solvent B) at the flow-rate 1 ml min(-1). Starting with solvent A an isocratic elution was performed for 15 min, then the composition was changed to 85% of A and 15% of B during the next 20 min and it was constant for 5 min, then the composition was changed to 70% of A and 30% of B during next 15 min and it was constant for 5 min and finally was changed to 100% of A as at the beginning of the elution. Detection was performed with diode array detector at 210, 230 and 254 nm. Multivitamin syrup preparation was subjected to stress testing (forced degradation) in order to demonstrate that degradants from the vitamins, preservatives and/or product excipients do not interfere with the quantification of vitamins and preservatives. Typical validation characteristics: selectivity, accuracy, precision, linearity, range, limit of quantification and limit of detection were evaluated for vitamins and preservatives.

  3. A randomised comparison of an everolimus-eluting coronary stent with a paclitaxel-eluting coronary stent:the SPIRIT II trial

    NARCIS (Netherlands)

    Serruys, Patrick W.; Ruygrok, Peter; Neuzner, Jörg; Piek, Jan J.; Seth, Ashok; Schofer, Joachim J.; Richardt, Gert; Wiemer, Marcus; Carrié, Didier; Thuesen, Leif; Boone, Els; Miquel-Herbert, Karine; Daemen, Joost

    2006-01-01

    Background: Everolimus has been successfully tested in humans using both an erodable and a durable polymer in small previous studies.Methods: This single blind multi-centre non-inferiority randomised (3:1) controlled trial evaluated the safety and performance of the XIENCE V Everolimus Eluting

  4. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial

    NARCIS (Netherlands)

    Serruys, Patrick W.; Chevalier, Bernard; Sotomi, Yohei; Cequier, Angel; Carrié, Didier; Piek, Jan J.; van Boven, Ad J.; Dominici, Marcello; Dudek, Dariusz; McClean, Dougal; Helqvist, Steffen; Haude, Michael; Reith, Sebastian; de Sousa Almeida, Manuel; Campo, Gianluca; Iñiguez, Andrés; Sabaté, Manel; Windecker, Stephan; Onuma, Yoshinobu

    2016-01-01

    No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrate two mechanistic properties of the bioresorbable scaffold: increase in luminal dimensions as a result of

  5. Study to modify the elution system in a sup(99m)Tc generator

    International Nuclear Information System (INIS)

    Delgado S, Baldomero.

    1979-01-01

    The sup(99m)Tc generator is a system that allows us to obtain sup(99m)Tc through the radioactive desintegration of 99 Mo, a radionuclide absorbed in an alumine chromatographic column, the sup(99m)Tc extraction is accomplished by elution and the 99 Mo remains at the column. In this work we try to modify the elution procedure of the generator. At present after eluating the generator, it must be dried with air, in order to support the column in an oxidant atmosphere to avoid the reduction of the technetiate. This reduction causes a low yield of elution, since the reduced species of the technetium can not be eluated. The drying of the column with air complicates a little the elution procedure, and we look to simplify it, the employed methods to resolve the problem were: a) adding an oxidant agent to the elution saline solution, b) adsorbing an oxidant in the alumina chromatographic column, after that the 99 Mo was settled. In the case a) the used oxidant agents were KMnO 4 , K 2 Cr 2 O 7 , NaNo 2 , etc. At concentration rates of 10 -7 M the obtained yields in high activity generators were of the 25-30%. In the case b) variable amounts of a disolution of 2.5 mg/ml of K 2 CrO 4 were adsorbed, the obtained yields in high activity generators were about 85-90%, this second procedure was better, it lets us keep the column wet and it is not necessary to dry it with air, and in this way it can be carried out more easily and efficiently the elution procedure. (author)

  6. Softening and elution of monomers in ethanol

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Asmussen, Erik; Munksgaard, E Christian

    2009-01-01

    The purpose of this study was to investigate the effect of light-curing protocol on softening and elution of monomers in ethanol as measured on a model polymer. It was a further aim to correlate the measured values with previously reported data on degree of conversion and glass transition...

  7. Bicarbonate Elution of Uranium from Amidoxime-Based Polymer Adsorbents for Sequestering Uranium from Seawater

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Horng-Bin [Department of Chemistry, University of Idaho, Moscow, Idaho 83844 USA; Wai, Chien M. [Department of Chemistry, University of Idaho, Moscow, Idaho 83844 USA; Kuo, Li-Jung [Pacific Northwest National Laboratory, Marine Sciences Laboratory, Sequim, Washington 98382 USA; Gill, Gary [Pacific Northwest National Laboratory, Marine Sciences Laboratory, Sequim, Washington 98382 USA; Tian, Guoxin [Lawrence Berkeley National Laboratory, Berkeley, California 94720 USA; Rao, Linfeng [Lawrence Berkeley National Laboratory, Berkeley, California 94720 USA; Das, Sadananda [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 USA; Mayes, Richard T. [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 USA; Janke, Christopher J. [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 USA

    2017-05-02

    Uranium adsorbed on amidoxime-based polyethylene fibers in simulated seawater can be quantitatively eluted using 3 M KHCO3 at 40°C. Thermodynamic calculations are in agreement with the experimental observation that at high bicarbonate concentrations (3 M) uranyl ions bound to amidoxime molecules are converted to uranyl tris-carbonato complex in the aqueous solution. The elution process is basically the reverse reaction of the uranium adsorption process which occurs at a very low bicarbonate concentration (~10-3 M) in seawater. In real seawater experiments, the bicarbonate elution is followed by a NaOH treatment to remove natural organic matter adsorbed on the polymer adsorbent. Using the sequential bicarbonate and NaOH elution, the adsorbent is reusable after rinsing with deionized water and the recycled adsorbent shows no loss of uranium loading capacity based on real seawater experiments.

  8. Clopidogrel discontinuation within the first year after coronary drug-eluting stent implantation

    DEFF Research Database (Denmark)

    Thim, Troels; Johansen, Martin Berg; Chisholm, Gro Egholm

    2014-01-01

    BACKGROUND: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. METHODS: We followed 4,154 patients treated with coronary drug-eluting ......BACKGROUND: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. METHODS: We followed 4,154 patients treated with coronary drug......-eluting stents in Western Denmark for 1 year and obtained data on redeemed clopidogrel prescriptions and major adverse cardiovascular events (MACE, i.e., cardiac death, myocardial infarction, or stent thrombosis) from medical databases. RESULTS: Discontinuation of clopidogrel within the first 3 months after...... stent implantation was associated with a significantly increased rate of MACE at 1-year follow-up (hazard ratio (HR) 2.06; 95% confidence interval (CI): 1.08-3.93). Discontinuation 3-6 months (HR 1.29; 95% CI: 0.70-2.41) and 6-12 months (HR 1.29; 95% CI: 0.54-3.07) after stent implantation were...

  9. A VALIDATED STABILITY INDICATED RP-HPLC METHOD FOR DUTASTERIDE

    OpenAIRE

    D. Pavan Kumar a, b *, Naga Jhansi a, G. Srinivasa Rao b, Kirti Kumar Jain a

    2018-01-01

    ABSTRACT A Simple, Stability indicating, Isocratic, reverse phase High Performance Liquid Chromatographic (RPLC) related substance method was developed for Dutasteride in API. This method separates the impurities which are co-eluting in the pharmacopeia method. Successful separation of degradation impurities and synthetic impurities was achieved by YMC Triat phenyl column. Chromatographic was carried out on YMC Triat phenyl (150 X 4.6 mm, 3.0µm) column using 0.01M Potassium Dihydrogen Pho...

  10. Degree of conversion and monomer elution of CQ/amine and TPO adhesives.

    Science.gov (United States)

    Pongprueksa, Pong; Miletic, Vesna; Janssens, Henriette; Van Landuyt, Kirsten L; De Munck, Jan; Godderis, Lode; Van Meerbeek, Bart

    2014-06-01

    To evaluate the effect of photo-initiator on the degree of conversion (DC) and elution of Bis-GMA and HEMA for 8 one-step adhesive formulations. We used Scotchbond Universal ('SBU-CQ/amine_4.0', 3M ESPE), containing about 2wt% camphorquinone (CQ) and 2wt% ethyl-4-dimethylamino benzoate (EDMAB), an experimental 'SBU-TPO_2.1' version, containing 2.1wt% diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide (TPO), and 6 experimental LUB adhesives (Kuraray Noritake), namely 'LUB-CQ/amine_0.7', 'LUB-CQ/amine_1.4', 'LUB-CQ/amine_4.0', 'LUB-TPO_0.35', 'LUB-TPO_0.7' and 'LUB-TPO_2.0', respectively containing 0.35wt% CQ and 0.35wt% EDMAB, 0.7wt% CQ and 0.7wt% EDMAB, 2.0wt% CQ and 2.0wt% EDMAB, 0.35wt% TPO, 0.7wt% TPO, and 2.0wt% TPO. DC was measured using micro-Raman spectroscopy. Additional specimens were immersed in ethanol for 24h to determine the elution of Bis-GMA and HEMA using HPLC. DC of the respective SBU and LUB adhesives was alike at high photo-initiator concentration. At low concentration, TPO was significantly more efficient than CQ/amine (LUB adhesives only). A statistically significant positive photo-initiator concentration effect on DC was noted for both CQ/amine and TPO (LUB adhesives only). A statistically significant inverse photo-initiator concentration effect on HEMA elution was noted for both the CQ/amine- and TPO-containing LUB adhesives. A significantly strong correlation was found between DC and Bis-GMA elution (R(2)=0.744, p=0.026), and between DC and HEMA elution (R(2)=0.913, p=0.002) for the LUB adhesives. The photo-initiator kind and concentration affect DC and the Bis-GMA/HEMA elution. TPO can be used as an alternative photo-initiator for CQ/amine. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  11. [Drug-eluting stent thrombosis and its pharmacological prevention].

    Science.gov (United States)

    Pershukov, I V; Batyraliev, T A

    2007-01-01

    The problem of drug eluting stents (DES) safety has been actively discussed throughout 2006 because of increase of frequency of development of late stent thromboses which were noted during almost 2 years after stenting. In December 2006 US Food and Drug Administration (FDA) advisory panel acknowledged increase of development of late stent thrombosis. At the same time FDA accepted new definition of stent-thrombosis suggested by the Academic Research Consortium. According to this definition thrombosis can be definite, probable and possible. Any unexplained death before end of follow-up in a trial should be considered thrombosis related. Recalculation of thrombosis rate using this definition caused pronounced increase of this parameter in previously conducted trials. Thrombosis rate rose from 0,6 to 3,3% for bare metal stents, from 0,8 to 3,6% for sirolimus eluting stents and from 1,3 to 3,5% for paclitaxel eluting stents. Professional cardiological and angiographical societies (ACC, AHA, SCAI) responding to FDA advisory panel published their proofs and vision of the problem of stent thrombosis. In February 2007 ACC, AHA, SCAI, American College of Surgeons and Association of Dentists published scientific bulletin in which described preventive measures aimed at lowering of risk of thrombosis development. This document contains strict recommendation to continue double antithrombotic therapy with aspirin and clopidogrel for 12 months after implantation of DES or abandonment of the use of this type of stents when long term double antithrombotic therapy is not possible.

  12. Determination of egg yolk xanthophylls by isocratic high-performance liquid chromatography.

    Science.gov (United States)

    Brulc, Lučka; Simonovska, Breda; Vovk, Irena; Glavnik, Vesna

    2013-11-29

    An isocratic HPLC method was developed for the determination of eight xanthophylls (lutein, capsanthin, zeaxanthin, canthaxanthin, β-apo-8'-carotenal, ethyl-8'-apo-β-carotene-8'-oate, citranaxanthin and β-cryptoxanthin; registered as additives in poultry feeding) in egg yolks. Optimum separation of all-E-isomers of these xanthophylls was achieved in less than 18min on a ProntoSIL C30 column at 27°C using acetone-methanol-0.5M triethylammonium acetate buffer pH 7 14:5:1 (v/v) as the mobile phase with a flow rate of 1mL/min using spectrophotometric detection at 450nm. Other mobile phases were also found suitable, including acetone-water 93:7 (v/v) and acetone-methanol 1:4 (v/v) and the influences of column temperature on the separation and addition of triethylammonium acetate buffer pH 7 to the mobile phase on enhancement of the peak areas were evaluated. Preparation of test solution from yolks included a short vortexing of 0.5g of yolk in 10mL of acetone, followed by 15min magnetic stirring under nitrogen and centrifugation. The method was validated for 5 analytes. The calibration range was between 0.04 and 2μg/mL and the mean recovery of the analytes (95%) and the intra-day precision of the method (RSD less than 5%) on three levels in triplicates were obtained. Analyses of eggs from four husbandry classes showed the presence of up to four xanthophylls (lutein, zeaxanthin, canthaxanthin and ethyl-8'-apo-β-carotene-8'-oate) and traces of β-cryptoxanthin. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Alternative sample-introduction technique to avoid breakthrough in gradient-elution liquid chromatography of polymers

    NARCIS (Netherlands)

    Reingruber, E.; Bedani, F.; Buchberger, W.; Schoenmakers, P.

    2010-01-01

    Gradient-elution liquid chromatography (GELC) is a powerful tool for the characterization of synthetic polymers. However, gradient-elution chromatograms often suffer from breakthrough phenomena. Breakthrough can be averted by using a sample solvent as weak as the mobile phase. However, this approach

  14. Toxic vessel reaction to an absorbable polymer-based paclitaxel-eluting stent in pig coronary arteries.

    Science.gov (United States)

    Jabara, Refat; Chronos, Nicolas; Tondato, Fernando; Conway, Damian; Molema, Warner; Park, Kenneth; Mabin, Tom; King, Spencer; Robinson, Keith

    2006-08-01

    The goal of this study was to evaluate a new drug-eluting stent (DES) comprising a bioabsorbable polymer eluting a moderate dose of paclitaxel in a clinically relevant animal model. Although DES limit restenosis, adverse vascular pathologies and toxicities continue to be of major concern. Optimization of DES components, especially completely absorbable polymers, may reduce these toxicities. Bare-metal (BM), absorbable polymer coating only (POLY), and polymer-based paclitaxel-eluting (PACL) stents were implanted in porcine coronary arteries using intravascular ultrasound (IVUS) to optimize stent apposition. The dose density of paclitaxel was 0.30-0.35 mcg/mm2, with in vitro elution studies demonstrating a gradual elution over 6-8 weeks. The animals were terminated at 1 week, 1 month and 3 months. Histopathologic and histomorphometric analyses were perform. The arteries with PACL showed extensive smooth muscle cell necrosis at 1 week and poor apposition of stent struts at 1 month (malapposition measured as gap width between strut and internal elastic lamina), with greater gap width compared to the BM and POLY groups (0.22 mm +/- 0.02 vs. 0.03 mm +/- 0.02 and 0.02 mm +/- 0.01, respectively; p stent malapposition and late neointimal thickening. Since the therapeutic window for paclitaxel may be narrower than currently inferred, thorough preclinical testing coupled with the polymer development process for stents eluting paclitaxel is needed.

  15. Drug elution from high-dose antibiotic-loaded acrylic cement: a comparative, in vitro study.

    Science.gov (United States)

    Gasparini, Giorgio; De Gori, Marco; Calonego, Giovanni; Della Bora, Tommaso; Caroleo, Benedetto; Galasso, Olimpio

    2014-11-01

    High-dose antibiotic-loaded acrylic cement (ALAC) is used for managing peri-prosthetic joint infections (PJIs). The marked increase in resistant high-virulence bacteria is drawing the attention of physicians toward alternative antimicrobial formulations loaded into acrylic bone cement. The aim of this in vitro study was to determine the elution kinetics of 14 different high-dose ALACs. All ALAC samples showed a burst release of antibiotics in the first hour, progressively decreasing over time, and elution curves strictly adhered to a nonlinear regression analysis formula. Among aminoglycosides, commonly seen as the most appropriate antibiotics to be loaded into the bone cement, the highest elution rate was that of tobramycin. Among the glycopeptides, a class of antibiotics that should be considered to treat PJIs because of the prevalence of aminoglycoside resistance, vancomycin showed better elution than teicoplanin. Clindamycin, which can be associated with aminoglycosides to prepare ALACs and represents a useful option against the most common pathogens responsible for PJIs, showed the highest absolute and relative elutions among all the tested formulations. A noticeable elution was also detected for colistin, an antibiotic of last resort for treating multidrug-resistant bacteria. The current study demonstrates theoretical advantages in the preparation of ALAC for some antibiotics not routinely used in the clinical setting for PJIs. The use of these antibiotics based on the infecting bacteria sensitivity may represent a useful option for physicians to eradicate PJIs. In vivo testing should be considered in the future to confirm the results of this study. Copyright 2014, SLACK Incorporated.

  16. Increasing flexibility in two-dimensional liquid chromatography by pulsed elution of the first dimension

    DEFF Research Database (Denmark)

    Jakobsen, Simon S.; Christensen, Jan H.; Verdier, Sylvain

    2017-01-01

    This work demonstrates the development of an online two-dimensional liquid chromatography (2D-LC) method where the first dimension column is eluted by a sequence of pulses of increasing eluotropic strength generated by the LC pumps (pulsed-elution 2D-LC). Between the pulses, the first dimension...... online comprehensive 2D-LC: undersampling, difficulties in refocusing, and lack of flexibility in the selection of column dimensions and flow rates because the two dimensions constrain each other. The pulsed-elution 2D-LC was applied for the analysis of a basic fraction of vacuum gas oil. Peak capacity...

  17. Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial

    DEFF Research Database (Denmark)

    Gutiérrez-Chico, Juan Luis; van Geuns, Robert Jan; Regar, Evelyn

    2011-01-01

    To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an 'all-comers' population of patients, in order to clarify the mechanism of eventual...

  18. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

    Science.gov (United States)

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Stettler, Christoph; Sangiorgi, Diego; D'Ascenzo, Fabrizio; Kimura, Takeshi; Briguori, Carlo; Sabatè, Manel; Kim, Hyo-Soo; De Waha, Antoinette; Kedhi, Elvin; Smits, Pieter C; Kaiser, Christoph; Sardella, Gennaro; Marullo, Antonino; Kirtane, Ajay J; Leon, Martin B; Stone, Gregg W

    2012-04-14

    The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare

  19. Histologic Assessment of Drug-Eluting Grafts Related to Implantation Site

    Directory of Open Access Journals (Sweden)

    Jean-Christophe Tille

    2016-02-01

    Full Text Available Drug-eluting vascular prostheses represent a new direction in vascular surgery to reduce early thrombosis and late intimal hyperplasia for small calibre grafts. Subcutaneous implantation in rats is a rapid and cost-effective screening model to assess the drug-elution effect and could, to some extent, be useful to forecast results for vascular prostheses. We compared biological and histological responses to scaffolds in different implantation sites. Polycaprolactone (PCL, paclitaxel-loaded PCL (PCL-PTX and dexamethasone-loaded PCL (PCL-DXM electrospun scaffolds were implanted subcutaneously and in an infrarenal abdominal aortic model in rats for up to 12 weeks. At the conclusion of the study, a histological analysis was performed. Cellular graft invasion revealed differences in the progression of cellular infiltration between PCL-PTX and PCL/PCL-DXM groups in both models. Cell infiltration increased over time in the aortic model compared to the subcutaneous model for all groups. Cell counting revealed major differences in fibroblast, macrophage and giant cell graft colonisation in all groups and models over time. Macrophages and giant cells increased in the PCL aortic model; whereas in the subcutaneous model these cell types increased only after three weeks or even decreased in the drug-eluting PCL groups. Other major findings were observed only in the aortic replacement such as extracellular matrix deposition and neo-angiogenesis. The subcutaneous implant model can be used for screening, especially when drug-eluting effects are studied. However, major histological differences were observed in cell type reaction and depth of cell penetration compared to the aortic model. Our results demonstrate that the implantation site is a critical determinant of the biological response.

  20. Patient-rated health status predicts prognosis following percutaneous coronary intervention with drug-eluting stenting

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Versteeg, Henneke; Denollet, Johan

    2011-01-01

    In patients treated with percutaneous coronary intervention (PCI) with the paclitaxel-eluting stent, we examined whether patient-rated health status predicts adverse clinical events.......In patients treated with percutaneous coronary intervention (PCI) with the paclitaxel-eluting stent, we examined whether patient-rated health status predicts adverse clinical events....

  1. Optimization of Drug Delivery by Drug-Eluting Stents.

    Directory of Open Access Journals (Sweden)

    Franz Bozsak

    Full Text Available Drug-eluting stents (DES, which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours or very slowly (over periods of several months up to one year at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.

  2. Validation of high-performance liquid chromatography (HPLC method for quantitative analysis of histamine in fish and fishery products

    Directory of Open Access Journals (Sweden)

    B.K.K.K. Jinadasa

    2016-12-01

    Full Text Available A high-performance liquid chromatography method is described for quantitative determination and validation of histamine in fish and fishery product samples. Histamine is extracted from fish/fishery products by homogenizing with tri-chloro acetic acid, separated with Amberlite CG-50 resin and C18-ODS Hypersil reversed phase column at ambient temperature (25°C. Linear standard curves with high correlation coefficients were obtained. An isocratic elution program was used; the total elution time was 10 min. The method was validated by assessing the following aspects; specificity, repeatability, reproducibility, linearity, recovery, limits of detection, limit of quantification and uncertainty. The validated parameters are in good agreement with method and it is a useful tool for determining histamine in fish and fishery products.

  3. Randomized comparison of a sirolimus-eluting Orsiro stent with a biolimus-eluting Nobori stent in patients treated with percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Maeng, Michael

    2015-01-01

    BACKGROUND: Third-generation coronary drug-eluting stents (DES) with biodegradable polymers have been designed to improve safety and efficacy. We designed a large scale registry-based randomized clinical trial to compare 2 third-generation DES: a thin strut, cobalt-chromium DES with silicon carbide......-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the stainless steel biodegradable polymer biolimus-eluting Nobori stents (N-BES, Nobori; Terumo, Tokyo, Japan) in an all-comer patient population. DESIGN: The multicenter SORT OUT VII trial (NCT01879358...... will be used. An event rate of 6.5% is assumed in each stent group. With a sample size of 1,157 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level will have 90% power to detect noninferiority of the O-SES compared with the N...

  4. Characterization of CRUDE OILS and petroleum products: (i) elution ...

    African Journals Online (AJOL)

    Characterization of CRUDE OILS and petroleum products: (i) elution liquid chromatographic separation and gas chromatographic analysis of crude oils and petroleum products. E.O. Odebunmi, E.A. Ogunsakin, P.E.P. Ilukhor ...

  5. Optimalizace HPLC metody pro separaci tetracyklinových antibiotik

    OpenAIRE

    Kučerová, Gabriela

    2011-01-01

    The aim of this work is to develop and to optimize HPLC method for separation of a set of four tetracycline antibiotics - tetracycline, chlortetracycline, oxytetracycline, and doxycycline. Four different reversed octadecyl-silica stationary phases in various mobile phase compositions were examined in isocratic elution. The baseline resolution of all the analytes was obtained by using two columns - Astec C18 and Atlantis C18 I. The optimized separation system consisted of Atlantis C18 I. colum...

  6. Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds: Evidence From a Network Meta-Analysis of 147 Trials.

    Science.gov (United States)

    Kang, Si-Hyuck; Chae, In-Ho; Park, Jin-Joo; Lee, Hak Seung; Kang, Do-Yoon; Hwang, Seung-Sik; Youn, Tae-Jin; Kim, Hyo-Soo

    2016-06-27

    This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS). Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year. A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization. Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices. Copyright © 2016 American College of Cardiology Foundation. Published by

  7. Influence of amount of oxidizing slag discharged from stainless steelmaking process of electric arc furnace on elution behavior into fresh water

    International Nuclear Information System (INIS)

    Yokoyama, S; Izaki, M; Shimomura, T; Hisyamudin, M N N; Takahashi, T

    2012-01-01

    Fundamental study was carried out for provision for acidification of soil due to acid rain. The influence of weight of the additive slag on elution behavior of the slag into water was studied in this study. Elution experiment was carried out on a basis of JIS K 0058-1. Generally, the pH in the aqueous solution increased with an increase in weight of the additive slag. The pH converged to approximately eight. Calcium, magnesium and manganese, which were essential elements for plants, were eluted from the slag irrespective to elution condition. The eluted concentrations of Ca and Mg increased with an increase in weight of the additive slag. Silicon and zinc were also eluted depending on the conditions. Aluminum that was harmful for plants was not eluted from the used slag.

  8. Influence of amount of oxidizing slag discharged from stainless steelmaking process of electric arc furnace on elution behavior into fresh water

    Science.gov (United States)

    Yokoyama, S.; Shimomura, T.; Hisyamudin, M. N. N.; Takahashi, T.; Izaki, M.

    2012-03-01

    Fundamental study was carried out for provision for acidification of soil due to acid rain. The influence of weight of the additive slag on elution behavior of the slag into water was studied in this study. Elution experiment was carried out on a basis of JIS K 0058-1. Generally, the pH in the aqueous solution increased with an increase in weight of the additive slag. The pH converged to approximately eight. Calcium, magnesium and manganese, which were essential elements for plants, were eluted from the slag irrespective to elution condition. The eluted concentrations of Ca and Mg increased with an increase in weight of the additive slag. Silicon and zinc were also eluted depending on the conditions. Aluminum that was harmful for plants was not eluted from the used slag.

  9. Randomized Comparison of Ridaforolimus- and Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: Primary Results From the BIONICS Trial (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis).

    Science.gov (United States)

    Kandzari, David E; Smits, Pieter C; Love, Michael P; Ben-Yehuda, Ori; Banai, Shmuel; Robinson, Simon D; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y; Balcells, Mercedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R; Leon, Martin B; Stone, Gregg W

    2017-10-03

    The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. URL: http

  10. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    Science.gov (United States)

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  11. The elution of certain protein affinity tags with millimolar concentrations of diclofenac.

    Science.gov (United States)

    Baliova, Martina; Juhasova, Anna; Jursky, Frantisek

    2015-12-01

    Diclofenac (2-[(2, 6-dichlorophenyl)amino] benzeneacetic acid) is a sparingly soluble, nonsteroidal anti-inflammatory drug therapeutically acting at low micromolar concentrations. In pH range from 8 to 11, its aqueous solubility can be increased up to 200 times by the presence of counter ions such as sodium. Our protein interaction studies revealed that a millimolar concentration of sodium diclofenac is able to elute glutathione S-transferase (GST), cellulose binding protein (CBD), and maltose binding protein (MBP) but not histidine-tagged or PDZ-tagged proteins from their affinity resins. The elution efficiency of diclofenac is comparable with the eluting agents normally used at similar concentrations. Native gel electrophoresis of sodium diclofenac-treated proteins showed that the interaction is non-covalent and non-denaturing. These results suggest that sodium diclofenac, in addition to its pharmaceutical applications, can also be exploited as a lead for the development of new proteomics reagents. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Meta-Analysis of Randomized Clinical Trials Comparing Biodegradable Polymer Drug-Eluting Stent to Second-Generation Durable Polymer Drug-Eluting Stents.

    Science.gov (United States)

    El-Hayek, Georges; Bangalore, Sripal; Casso Dominguez, Abel; Devireddy, Chandan; Jaber, Wissam; Kumar, Gautam; Mavromatis, Kreton; Tamis-Holland, Jacqueline; Samady, Habib

    2017-03-13

    The authors sought to perform a meta-analysis of randomized clinical trials (RCTs) comparing the safety and efficacy of biodegradable polymer drug-eluting stents (BP-DES) to second-generation durable polymer drug-eluting stents (DP-DES). Prior meta-analyses have established the superiority of BP-DES over bare-metal stents and first-generation DP-DES; however, their advantage compared with second-generation DP-DES remains controversial. The authors searched PubMed and Scopus databases for RCTs comparing BP-DES to the second-generation DP-DES. Outcomes included target vessel revascularization (TVR) as efficacy outcome and cardiac death, myocardial infarction (MI), and definite or probable stent thrombosis (ST) as safety outcomes. In addition, we performed landmark analysis for endpoints beyond 1 year of follow-up and a subgroup analysis based on the stent characteristics. The authors included 16 RCTs comprising 19,886 patients in the meta-analysis. At the longest available follow-up (mean duration 26 months), we observed no significant differences in TVR (p = 0.62), cardiac death (p = 0.46), MI (p = 0.98), or ST (risk ratio: 0.83, 95% confidence interval: 0.64 to 1.09; p = 0.19). Our landmark analysis showed that BP-DES were not associated with a reduction in the risk of very late ST (risk ratio: 0.87, 95% confidence interval: 0.49 to 1.53; p = 0.62). Similar outcomes were seen regardless of the eluting drug (biolimus vs. sirolimus), the stent platform (stainless steel vs. alloy), the kinetics of polymer degradation or drug release (6 months), the strut thickness of the BP-DES (thin 100 μm), or the DAPT duration (≥6 months vs. ≥12 months). BP-DES have similar safety and efficacy profiles to second-generation DP-DES. Published by Elsevier Inc.

  13. Establishing conditions for the storage and elution of rabies virus RNA using FTA® cards

    Science.gov (United States)

    SAKAI, Takeo; ISHII, Ayako; SEGAWA, Takao; TAKAGI, Yukihiko; KOBAYASHI, Yuki; ITOU, Takuya

    2014-01-01

    The Flinders Technology Associates filter paper cards (FTA® cards) can be used to store nucleic acid from various samples and are easily portable. However, RNA is physicochemically unstable compared with DNA, and appropriate methods have not been established for storage and extraction of RNA from FTA® cards. The present study investigated the optimum conditions for storage and elution of viral RNA (vRNA) using rabies virus (RABV) applied to FTA® cards. When TE buffer was used, the elution rates of vRNA increased with the length of the elution time. When the cards were stored at −80°C or −20°C, vRNA was stable over 3 months. Degradation of vRNAs occurred following storage at 4°C and room temperature, suggesting that RNA should be extracted from cards as soon as possible if no freezer is available. When we tried to amplify vRNA from RABV-infected animal brains applied to FTA® cards and stored at −80°C for 6 months, we did not detect any amplified products with the primer set for 964 bp of RABV N gene. However, we were able to detect amplified products by increasing the elution time of vRNA from FTA® cards from 30 min to 24 hr or by changing the primer sets to amplify 290 bp of N gene. Thus, we recommend extending the elution time for damaged or low concentration samples in FTA® cards. PMID:25648208

  14. Aluminum elution and precipitation in glass vials: effect of pH and buffer species.

    Science.gov (United States)

    Ogawa, Toru; Miyajima, Makoto; Wakiyama, Naoki; Terada, Katsuhide

    2015-02-01

    Inorganic extractables from glass vials may cause particle formation in the drug solution. In this study, the ability of eluting Al ion from borosilicate glass vials, and tendencies of precipitation containing Al were investigated using various pHs of phosphate, citrate, acetate and histidine buffer. Through heating, all of the buffers showed that Si and Al were eluted from glass vials in ratios almost the same as the composition of borosilicate glass, and the amounts of Al and Si from various buffer solutions at pH 7 were in the following order: citrate > phosphate > acetate > histidine. In addition, during storage after heating, the Al concentration at certain pHs of phosphate and acetate buffer solution decreased, suggesting the formation of particles containing Al. In citrate buffer, Al did not decrease in spite of the high elution amount. Considering that the solubility profile of aluminum oxide and the Al eluting profile of borosilicate glass were different, it is speculated that Al ion may be forced to leach into the buffer solution according to Si elution on the surface of glass vials. When Al ions were added to the buffer solutions, phosphate, acetate and histidine buffer showed a decrease of Al concentration during storage at a neutral range of pHs, indicating the formation of particles containing Al. In conclusion, it is suggested that phosphate buffer solution has higher possibility of forming particles containing Al than other buffer solutions.

  15. Drug-eluting stents and bare metal stents in patients with NSTE-ACS

    DEFF Research Database (Denmark)

    Pedersen, Sune Haahr; Pfisterer, Matthias; Kaiser, Christoph

    2014-01-01

    the randomised BASKET-PROVE trial (sirolimus-eluting stent vs. everolimus-eluting stent vs. bare metal stent in large-vessel stenting). The primary endpoint was the combined two-year rate of cardiovascular death or non-fatal myocardial infarction (MI). Secondary endpoints were each component of the primary...... implantation in large vessels was associated with a reduction in both TVR and the combined endpoint consisting of cardiovascular death/MI. Thus, DES use improves both efficacy and safety. These findings support the use of DES in NSTE-ACS patients....

  16. Isolation and Characterization of Chinese Standard Fulvic Acid Sub-fractions Separated from Forest Soil by Stepwise Elution with Pyrophosphate Buffer

    Science.gov (United States)

    Bai, Yingchen; Wu, Fengchang; Xing, Baoshan; Meng, Wei; Shi, Guolan; Ma, Yan; Giesy, John P.

    2015-01-01

    XAD-8 adsorption technique coupled with stepwise elution using pyrophosphate buffers with initial pH values of 3, 5, 7, 9, and 13 was developed to isolate Chinese standard fulvic acid (FA) and then separated the FA into five sub-fractions: FApH3, FApH5, FApH7, FApH9 and FApH13, respectively. Mass percentages of FApH3-FApH13 decreased from 42% to 2.5%, and the recovery ratios ranged from 99.0% to 99.5%. Earlier eluting sub-fractions contained greater proportions of carboxylic groups with greater polarity and molecular mass, and later eluting sub-fractions had greater phenolic and aliphatic content. Protein-like components, as well as amorphous and crystalline poly(methylene)-containing components were enriched using neutral and basic buffers. Three main mechanisms likely affect stepwise elution of humic components from XAD-8 resin with pyrophosphate buffers including: 1) the carboxylic-rich sub-fractions are deprotonated at lower pH values and eluted earlier, while phenolic-rich sub-fractions are deprotonated at greater pH values and eluted later. 2) protein or protein-like components can be desorbed and eluted by use of stepwise elution as progressively greater pH values exceed their isoelectric points. 3) size exclusion affects elution of FA sub-fractions. Successful isolation of FA sub-fractions will benefit exploration of the origin, structure, evolution and the investigation of interactions with environmental contaminants. PMID:25735451

  17. SOLID-PHASE EXTRACTION OF MORPHINE FROM WHOLE-BLOOD BY MEANS OF BOND ELUT CERTIFY COLUMNS

    NARCIS (Netherlands)

    CHEN, XH; HOMMERSON, ALC; ZWEIPFENNING, PGM; FRANKE, JP; HARMENBOVERHOF, CW; ENSING, K; DEZEEUW, RA

    The use of Bond Elut Certify columns for the isolation of morphine from whole blood was evaluated. In order to monitor possible losses and the elution profile of morphine, a small amount of the tritiated analogue was added to the samples. Four sample pretreatment methods, three protein precipitation

  18. Efficacy and Safety of Drug-Eluting Stents in the Real World: 8-Year Follow-Up

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, Denise Oliveira, E-mail: dennizmo@yahoo.com.br; Gomes, Vitor Osório; Lasevitch, Ricardo; Smidt, Luis; Azeredo, Marco Aurélio; Ledur, Priscila; Bodanese, Rodrigo; Sinnott, Leonardo; Moriguchi, Emílio; Caramori, Paulo [Hospital São Lucas PUC, Porto Alegre, RS (Brazil)

    2014-09-15

    Drug-eluting stents have been used in daily practice since 2002, with the clear advantages of reducing the risk of target vessel revascularization and an impressive reduction in restenosis rate by 50%-70%. However, the occurrence of a late thrombosis can compromise long-term results, particularly if the risks of this event were sustained. In this context, a registry of clinical cases gains special value. To evaluate the efficacy and safety of drug-eluting stents in the real world. We report on the clinical findings and 8-year follow-up parameters of all patients that underwent percutaneous coronary intervention with a drug-eluting stent from January 2002 to April 2007. Drug-eluting stents were used in accordance with the clinical and interventional cardiologist decision and availability of the stent. A total of 611 patients were included, and clinical follow-up of up to 8 years was obtained for 96.2% of the patients. Total mortality was 8.7% and nonfatal infarctions occurred in 4.3% of the cases. Target vessel revascularization occurred in 12.4% of the cases, and target lesion revascularization occurred in 8% of the cases. The rate of stent thrombosis was 2.1%. There were no new episodes of stent thrombosis after the fifth year of follow-up. Comparative subanalysis showed no outcome differences between the different types of stents used, including Cypher®, Taxus®, and Endeavor®. These findings indicate that drug-eluting stents remain safe and effective at very long-term follow-up. Patients in the 'real world' may benefit from drug-eluting stenting with excellent, long-term results.

  19. Analysis of the role of elution buffers on the separation capabilities of dielectrophoretic devices

    Directory of Open Access Journals (Sweden)

    Rossana Di Martino

    2016-03-01

    Full Text Available Field flow fractionation dielectrophoretic (FFF-DEP devices are currently used, among the others, for the separation of tumor cells from healthy blood cells. To this end specific suspension/elution buffers (EBs, with reduced conductivity (with respect to that of the cell cytoplasm are generally used. In this paper we investigate the long-term alterations of the cells and elution buffers. We find that the EB conductivity is critically modified within few minutes after cells suspension. In turn, this modification results in a change the ideal separation frequency of the FFF-DEP device. On the other hand we prove that DEP manipulation is preserved for more than three hours for cells suspended in the considered EBs. Keywords: Dielectrophoresis, Elution buffer, Circulating tumor cells, Cell motility

  20. Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry Measurement of Caffeine in Caffeine-Laced Pants and in Urine and Skin of a Pants User

    OpenAIRE

    Pellegrini, Manuela; Orsi, Daniela De; Guarino, Carmine; Rotolo, Maria; Giovannandrea, Rita di; Pacifici, Roberta; Pichini, Simona

    2014-01-01

    A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry method was developed for the measurement of caffeine in caffeine-laced pants and in urine and skin of a pants user. The substance and its internal standard (N-ethylnorcotinine) were separated by reversed phase chromatography with 5 mM ammonium formate pH 3.0 and 0.3% formic acid in acetonitrile mobile phase (83:17 v/v) by isocratic elution and detected by tandem mass spectrometry operated in multiple reacti...

  1. Safety and Efficacy of Everolimus- Versus Sirolimus-Eluting Stents

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Christiansen, Evald Høj

    2016-01-01

    BACKGROUND: Long-term safety and efficacy for everolimus-eluting stents (EES) versus those of sirolimus-eluting stents (SES) are unknown. OBJECTIVES: This study compared 5-year outcomes for EES with those for SES from the SORT OUT IV (Scandinavian Organization for Randomized Trials with Clinical...... rate was lower with EES (HR: 0.71, 95% CI: 0.55 to 0.90; p = 0.006; p interaction = 0.12). Definite stent thrombosis was lower with EES (0.4%) than with SES (2.0%; HR: 0.18, 95% CI: 0.07 to 0.46), with a lower risk of very late definite stent thrombosis in the EES group (0.2% vs. 1.4%, respectively; HR...... in Non-selected Patients With Coronary Heart Disease [SORT OUT IV]; NCT00552877)....

  2. Development of a pheromone elution rate physical model

    Science.gov (United States)

    M.E. Teske; H.W. Thistle; B.L. Strom; H. Zhu

    2015-01-01

    A first principle modeling approach has been applied to available data describing the elution of semiochemicals from pheromone dispensers. These data included field data for 27 products developed by several manufacturers, including homemade devices, as well as environmental chamber data collected on three semiochemical products. The goal of this effort was to...

  3. Cefoperazone and cefoperazone-sulbactam susceptibility tests with anaerobic bacteria by the thioglycolate disk elution method.

    OpenAIRE

    Barry, A L; Packer, R R; Jones, R N

    1985-01-01

    Tests were performed with 104 anaerobic microorganisms to evaluate the thioglycolate disk elution technique for the detection of resistance to cefoperazone and cefoperazone-sulbactam. An unacceptably high false-resistance rate and a poor reproducibility record make the disk elution procedure unsatisfactory for routine testing of this drug or combination of drugs.

  4. Elution behavior of poly(ethylene glycol) through poly(vinyl alcohol) gel column using several solvents as eluents

    International Nuclear Information System (INIS)

    Hirayama, Chuichi; Motozato, Yoshiaki; Matsumoto, Kazuaki.

    1983-01-01

    γ-Irradiated poly(vinyl alcohol) beads, which were sufficiently allowed to swell in water, were washed with methanol, and then were packed into column. Gel chromatography was performed using methanol, benzene, esters and ketones as eluents and poly(ethylene glycol) as a sample. When the elution was carried out using methanol and benzene as eluents, elution behavior of samples was ordinary. When ethyl formate, methyl acetate and ethyl propionate were used as eluents, samples were slightly adsorbed and the elution was delayed. In the case the elution was carried out using ethyl acetate, propyl acetate, butyl acetate and ethyl methyl ketone as eluents, samples were adsorbed strongly on the bed material, and the adsorption curve was analogous to the calibration curve using methanol as an eluent. Dried poly(vinyl alcohol) gel as a packing material, showed ordinary elution behaviors for the samples. The adsorption of poly(ethylene glycol) on the present bed material was attributed to the existence of hydrated water on poly(vinyl alcohol) gel matrix. (author)

  5. Analysis of long-term monomer elution from bulk-fill and conventional resin-composites using high performance liquid chromatography.

    Science.gov (United States)

    Alshali, Ruwaida Z; Salim, Nesreen A; Sung, Rehana; Satterthwaite, Julian D; Silikas, Nick

    2015-12-01

    The aim of this study was to assess monomer elution from bulk-fill and conventional resin-composites stored in different media using high performance liquid chromatography (HPLC) for up to 3 months. Six bulk-fill (SureFil SDR, Venus Bulk Fill, X-tra base, Filtek Bulk Fill flowable, Sonic Fill, and Tetric EvoCeram Bulk Fill) and eight conventional resin-composites (Grandioso Flow, Venus Diamond Flow, X-Flow, Filtek Supreme XTE, Grandioso, Venus Diamond, TPH Spectrum, and Filtek Z250) were tested. Cylindrical samples (n=5) were immersed in water, 70% ethanol/water solution (70% E/W), and artificial saliva and stored at 37°C for 24h, 1 month, and 3 months. The storage solutions were analysed with HPLC. Data were analysed with repeated measures ANOVA, one-way ANOVA, and Tukey post hoc test at α=0.05. Monomers detected in water and artificial saliva were TEGDMA, DEGDMA, UDMA, and TCD-DI-HEA. No eluted monomers were detected from X-tra base and Sonic fill in these media. All monomers showed a variable extent of elution into 70% E/W with significantly higher amounts than those detected in water and artificial saliva. Significantly higher elution was detected from UDMA-BisEMA based composites compared to BisGMA and BisGMA-BisEMA based systems in 70% E/W. The rate of elution into different media varied between different monomers and was highly dependent on the molecular weight of the eluted compounds. Elution from bulk-fill resin-composites is comparable to that of conventional materials despite their increased increment thickness. Monomer elution is highly dependent on the hydrophobicity of the base monomers and the final network characteristics of the resin-matrix. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Possibility of obtaining enriched americium-242g by the elution of recoil atoms from zeolite

    Energy Technology Data Exchange (ETDEWEB)

    Shafiev, A I; Vityutnev, V M; Ivanov, V M; Yakovlev, G N

    1974-12-31

    On the example of production the possibility of obtaining enriched actinide isotopes by the elution of recotl atoms with the use of a zeolite- americium-241 target was shown. The enrichment factor and the recoil atoms of / sup 242g/Am yield depend on preliminary target treatment and solution composition used for elution. (auth)

  7. Percutaneous coronary intervention with second-generation paclitaxel-eluting stents versus everolimus-eluting stents in United States contemporary practice (REWARDS TLX Trial).

    Science.gov (United States)

    Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca

    2012-10-15

    Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Studies on the production of technetium-99m generators based on gel elution

    International Nuclear Information System (INIS)

    Castro, M.

    1993-12-01

    Technetium-99m generator based on Ti Mo elution has been carried out. The gel matrix was prepared by mixing non-irradiated molybdate with Titanium Chloride solution. Conditions of preparing and drying Ti Mo were evaluated as a function of elution yield. Thus, pH and water content were found highly critical for reproductiveness of the results. Non-elutable form of Tc-99m can be oxidized treating the target after irradiation with K 2 Cr 2 O 7 0.001M solution. During several experiments the columns were soaked with this oxidizing solution for one hour and afterwards the Ti Mo was washed with 150 ml physiological saline. Daily elutions were done with 10 ml of NaCl 0.9%. Cooling water reactor during irradiation quartz ampoules has been studied. To study this effect, one group of samples were irradiated in aluminium caps air-tight screw and another one was irradiated in drilled caps with six holes to permit water reactor recirculation around quartz ampoules. By combination K 2 Cr 2 O 7 target treatment and cooling Ti Mo during irradiation is possible to get yields of Tc-99m near to 76%. The radiochemical purity was > 99% and Al content < 10ppm , Cr < 0.05ppm , Mo <20ppm, Ti was no detected. Biological scans practiced in animals have been considered satisfactory. (author). 8 refs., 7 tabs., 3 figs

  9. Optimized pH method for DNA elution from buccal cells collected in Whatman FTA cards.

    Science.gov (United States)

    Lema, Carolina; Kohl-White, Kendra; Lewis, Laurie R; Dao, Dat D

    2006-01-01

    DNA is the most accessible biologic material for obtaining information from the human genome because of its molecular stability and its presence in every nucleated cell. Currently, single nucleotide polymorphism genotyping and DNA methylation are the main DNA-based approaches to deriving genomic and epigenomic disease biomarkers. Upon the discontinuation of the Schleicher & Schuell IsoCode product (Dassel, Germany), which was a treated paper system to elute DNA from several biologic sources for polymerase chain reaction (PCR) analysis, a high-yielding DNA elution method was imperative. We describe here an improved procedure of the not fully validated Whatman pH-based elution protocol. Our DNA elution procedure from buccal cells collected in Whatman FTA cards (Whatman Inc., Florham Park, NJ) yielded approximately 4 microg of DNA from a 6-mm FTA card punch and was successfully applied for HLA-DQB1 genotyping. The genotypes showed complete concordance with data obtained from blood of the same subjects. The achieved high DNA yield from buccal cells suggests a potential cost-effective tool for genomic and epigenomic disease biomarkers development.

  10. Establishing conditions for the storage and elution of rabies virus RNA using FTA(®) cards.

    Science.gov (United States)

    Sakai, Takeo; Ishii, Ayako; Segawa, Takao; Takagi, Yukihiko; Kobayashi, Yuki; Itou, Takuya

    2015-04-01

    The Flinders Technology Associates filter paper cards (FTA(®) cards) can be used to store nucleic acid from various samples and are easily portable. However, RNA is physicochemically unstable compared with DNA, and appropriate methods have not been established for storage and extraction of RNA from FTA(®) cards. The present study investigated the optimum conditions for storage and elution of viral RNA (vRNA) using rabies virus (RABV) applied to FTA(®) cards. When TE buffer was used, the elution rates of vRNA increased with the length of the elution time. When the cards were stored at -80 °C or -20 °C, vRNA was stable over 3 months. Degradation of vRNAs occurred following storage at 4 °C and room temperature, suggesting that RNA should be extracted from cards as soon as possible if no freezer is available. When we tried to amplify vRNA from RABV-infected animal brains applied to FTA(®) cards and stored at -80 °C for 6 months, we did not detect any amplified products with the primer set for 964 bp of RABV N gene. However, we were able to detect amplified products by increasing the elution time of vRNA from FTA(®) cards from 30 min to 24 hr or by changing the primer sets to amplify 290 bp of N gene. Thus, we recommend extending the elution time for damaged or low concentration samples in FTA(®) cards.

  11. Gradient elution behavior of proteins in hydrophobic interaction chromatography with U-shaped retention factor curves.

    Science.gov (United States)

    Creasy, Arch; Lomino, Joseph; Barker, Gregory; Khetan, Anurag; Carta, Giorgio

    2018-04-27

    Protein retention in hydrophobic interaction chromatography is described by the solvophobic theory as a function of the kosmostropic salt concentration. In general, an increase in salt concentration drives protein partitioning to the hydrophobic surface while a decrease reduces it. In some cases, however, protein retention also increases at low salt concentrations resulting in a U-shaped retention factor curve. During gradient elution the salt concentration is gradually decreased from a high value thereby reducing the retention factor and increasing the protein chromatographic velocity. For these conditions, a steep gradient can overtake the protein in the column, causing it to rebind. Two dynamic models, one based on the local equilibrium theory and the other based on the linear driving force approximation, are presented. We show that the normalized gradient slope determines whether the protein elutes in the gradient, partially elutes, or is trapped in the column. Experimental results are presented for two different monoclonal antibodies and for lysozyme on Capto Phenyl (High Sub) resin. One of the mAbs and lysozyme exhibit U-shaped retention factor curves and for each, we determine the critical gradient slope beyond which 100% recovery is no longer possible. Elution with a reverse gradient is also demonstrated at low salt concentrations for these proteins. Understanding this behavior has implications in the design of gradient elution since the gradient slope impacts protein recovery. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. A rapid and accurate approach for prediction of interactomes from co-elution data (PrInCE).

    Science.gov (United States)

    Stacey, R Greg; Skinnider, Michael A; Scott, Nichollas E; Foster, Leonard J

    2017-10-23

    An organism's protein interactome, or complete network of protein-protein interactions, defines the protein complexes that drive cellular processes. Techniques for studying protein complexes have traditionally applied targeted strategies such as yeast two-hybrid or affinity purification-mass spectrometry to assess protein interactions. However, given the vast number of protein complexes, more scalable methods are necessary to accelerate interaction discovery and to construct whole interactomes. We recently developed a complementary technique based on the use of protein correlation profiling (PCP) and stable isotope labeling in amino acids in cell culture (SILAC) to assess chromatographic co-elution as evidence of interacting proteins. Importantly, PCP-SILAC is also capable of measuring protein interactions simultaneously under multiple biological conditions, allowing the detection of treatment-specific changes to an interactome. Given the uniqueness and high dimensionality of co-elution data, new tools are needed to compare protein elution profiles, control false discovery rates, and construct an accurate interactome. Here we describe a freely available bioinformatics pipeline, PrInCE, for the analysis of co-elution data. PrInCE is a modular, open-source library that is computationally inexpensive, able to use label and label-free data, and capable of detecting tens of thousands of protein-protein interactions. Using a machine learning approach, PrInCE offers greatly reduced run time, more predicted interactions at the same stringency, prediction of protein complexes, and greater ease of use over previous bioinformatics tools for co-elution data. PrInCE is implemented in Matlab (version R2017a). Source code and standalone executable programs for Windows and Mac OSX are available at https://github.com/fosterlab/PrInCE , where usage instructions can be found. An example dataset and output are also provided for testing purposes. PrInCE is the first fast and easy

  13. Utilization of Photochemically Induced Fluorescence Detection for HPLC Determination of Genotoxic Impurities in the Vortioxetine Manufacturing Process.

    Science.gov (United States)

    Douša, Michal; Doubský, Jan; Srbek, Jan

    2016-07-01

    An analytical reversed-phase high-performance liquid chromatography (HPLC) method for the detection and quantitative determination of two genotoxic impurities at ppm level present in the vortioxetine manufacturing process is described. Applying the concept of threshold of toxicological concern, a limit of 75 ppm each for both genotoxic impurities was calculated based on the maximum daily dose of active pharmaceutical ingredients. The novel reversed-phase HPLC method with photochemically induced fluorescence detection was developed on XSELECT Charged Surface Hybrid Phenyl-Hexyl column using the mobile phase consisted a mixture of 10 mM ammonium formate pH 3.0 and acetonitrile. The elution was performed using an isocratic composition of 48:52 (v/v) at a flow rate of 1.0 mL/min. The photochemically induced fluorescence detection is based on the use of UV irradiation at 254 nm through measuring the fluorescence intensity at 300 nm and an excitation wavelength of 272 nm to produce fluorescent derivatives of both genotoxic impurities. The online photochemical conversion and detection is easily accomplished for two expected genotoxic impurities and provides a sufficiently low limit detection and quantification for the target analysis. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Transarterial chemoembolization with drug-eluting beads in hepatocellular carcinoma

    Science.gov (United States)

    Nam, Hee Chul; Jang, Bohyun; Song, Myeong Jun

    2016-01-01

    Transarterial chemoembolization (TACE) is a widely used standard treatment for patients with hepatocellular carcinoma (HCC) who are not suitable candidates for curative treatments. The rationale for TACE is that intra-arterial chemotherapy using lipiodol and chemotherapeutic agents, followed by selective vascular embolization, results in a strong cytotoxic effect as well as ischemia (conventional TACE). Recently, drug-eluting beads (DC Beads®) have been developed for transcatheter treatment of HCC to deliver higher doses of the chemotherapeutic agent and to prolong contact time with the tumor. DC Beads® can actively sequester doxorubicin hydrochloride from solution and release it in a controlled sustained fashion. Treatment with DC Beads® substantially reduced the amount of chemotherapeutic agent that reached the systemic circulation compared with conventional, lipiodol-based regimens, significantly reducing drug-related adverse events. In this article, we describe the treatment response, survival, and safety of TACE used with drug-eluting beads for the treatment of HCC and discuss future therapeutic possibilities. PMID:27833376

  15. Impact of ultrasonication time on elution of super heavy oil and its biomarkers from aging soils using a Triton X-100 micellar solution

    International Nuclear Information System (INIS)

    Ji Guodong; Zhou Guohui

    2010-01-01

    An ultrasound-enhanced elution system with Triton X-100 solution was used to remediate aging soils contaminated with super heavy oil. We used GC/MS, SEM, and X-ray diffraction (XRD) to analyze the effect of ultrasonic time (0-1800 s) on the elution of super heavy oil and its three characteristic biomarkers (C 26-34 17α 25-norhopanes, C 26-28 triaromatic steroid [TAS], and C 27-29 methyl triaromatic steroid [MTAS]). The oil and biomarkers remaining in the treated soils followed similar second-order functions with increasing ultrasonication times. Biomarker elution was closely related to carbon numbers in the marker. For C 26-34 17α 25-norhopanes, the smaller molecules were more readily eluted during 0-360 s ultrasound. This trend was reversed upon application of ultrasound during 1080-1800 s, with improved elution of larger molecules and elution followed a similar second-order function. For C 26-28 TAS, smaller molecules were more readily eluted but the elution of larger molecules followed a similar second-order function. For C 27-29 MTAS, elution of larger molecules was close to that of C 26-34 17α 25-norhopanes. Results of SEM and XRD indicated that the mineral and chemical compositions of soils eluted at ultrasonication times of 1080-1800 s closely resembled clean soils.

  16. Temperature-based on-column solute focusing in capillary liquid chromatography reduces peak broadening from pre-column dispersion and volume overload when used alone or with solvent-based focusing.

    Science.gov (United States)

    Groskreutz, Stephen R; Horner, Anthony R; Weber, Stephen G

    2015-07-31

    On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection and then rapidly heating the focusing segment to the match the column temperature. A troublesome feature of an earlier implementation of TASF was the need to leave the capillary column unpacked in that portion of the column inside the fitting connecting it to the injection valve. We have overcome that problem in this work by packing the head of the column with solid silica spheres. In addition, technical improvements to the TASF instrumentation include: selection of a more powerful thermo-electric cooler to create faster temperature changes and electronic control for easy incorporation into conventional capillary instruments. Used in conjunction with solvent-based focusing and with isocratic elution, volumes of paraben samples (esters of p-hydroxybenzoic acid) up to 4.5-times the column liquid volume can be injected without significant bandspreading due to volume overload. Interestingly, the shapes of the peaks from the lowest volume injections that we can make, 30nL, are improved when using TASF. TASF is very effective at reducing the detrimental effects of pre-column dispersion using isocratic elution. Finally, we show that TASF can be used to focus the neuropeptide galanin in a sample solvent with elution strength stronger than the mobile phase. Here, the stronger solvent is necessitated by the need to prevent peptide adsorption prior to and during analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Temperature-based on-column solute focusing in capillary liquid chromatography reduces peak broadening from precolumn dispersion and volume overload when used alone or with solvent-based focusing

    Science.gov (United States)

    Groskreutz, Stephen R.; Horner, Anthony R.; Weber, Stephen G.

    2015-01-01

    On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection and then rapidly heating the focusing segment to the match the column temperature. A troublesome feature of an earlier implementation of TASF was the need to leave the capillary column unpacked in that portion of the column inside the fitting connecting it to the injection valve. We have overcome that problem in this work by packing the head of the column with solid silica spheres. In addition, technical improvements to the TASF instrumentation include: selection of a more powerful thermo-electric cooler to create faster temperature changes and electronic control for easy incorporation into conventional capillary instruments. Used in conjunction with solvent-based focusing and with isocratic elution, volumes of paraben samples (esters of p-hydroxybenzoic acid) up to 4.5-times the column liquid volume can be injected without significant bandspreading due to volume overload. Interestingly, the shapes of the peaks from the lowest volume injections that we can make, 30 nL, are improved when using TASF. TASF is very effective at reducing the detrimental effects of precolumn dispersion using isocratic elution. Finally, we show that TASF can be used to focus the neuropeptide galanin in a sample solvent with elution strength stronger than the mobile phase. Here, the stronger solvent is necessitated by the need to prevent peptide adsorption prior to and during analysis. PMID:26091787

  18. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    OpenAIRE

    Hassib, Sonia T.; Farag, Awatef E.; Elkady, Ehab F.

    2011-01-01

    Simple, accurate and precise reversed-phase liquid chromatographic (LC) and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS) and trimethoprim (TMP) in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm) based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9):acetonitrile:water (25:100:50, v/v/v) at a flow rate of 1...

  19. Simultaneous Determination of Ciprofloxacin Hydrochloride and Dexamethasone Sodium Phosphate in Eye Drops by HPLC

    OpenAIRE

    Katakam, Prakash; Sireesha, Karanam R.

    2012-01-01

    A liquid chromatographic method was developed and validated for the simultaneous determination of ciprofloxacin hydrochloride and dexamethasone sodium phosphate in bulk and pharmaceutical formulations. Optimum separation was achieved in less than 5 min using a C18 column (250 mmx4.6 mm i.d, 5μ particle size) by isocratic elution. The mobile phase consisting of a mixture of mixed phosphate buffer (pH 4) and acetonitrile (65:35, v/v) was used. Column effluents were monitored at 254 nm at a flow...

  20. Determination of reversed-phase high performance liquid chromatography based octanol-water partition coefficients for neutral and ionizable compounds: Methodology evaluation.

    Science.gov (United States)

    Liang, Chao; Qiao, Jun-Qin; Lian, Hong-Zhen

    2017-12-15

    Reversed-phase liquid chromatography (RPLC) based octanol-water partition coefficient (logP) or distribution coefficient (logD) determination methods were revisited and assessed comprehensively. Classic isocratic and some gradient RPLC methods were conducted and evaluated for neutral, weak acid and basic compounds. Different lipophilicity indexes in logP or logD determination were discussed in detail, including the retention factor logk w corresponding to neat water as mobile phase extrapolated via linear solvent strength (LSS) model from isocratic runs and calculated with software from gradient runs, the chromatographic hydrophobicity index (CHI), apparent gradient capacity factor (k g ') and gradient retention time (t g ). Among the lipophilicity indexes discussed, logk w from whether isocratic or gradient elution methods best correlated with logP or logD. Therefore logk w is recommended as the preferred lipophilicity index for logP or logD determination. logk w easily calculated from methanol gradient runs might be the main candidate to replace logk w calculated from classic isocratic run as the ideal lipophilicity index. These revisited RPLC methods were not applicable for strongly ionized compounds that are hardly ion-suppressed. A previously reported imperfect ion-pair RPLC method was attempted and further explored for studying distribution coefficients (logD) of sulfonic acids that totally ionized in the mobile phase. Notably, experimental logD values of sulfonic acids were given for the first time. The IP-RPLC method provided a distinct way to explore logD values of ionized compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Method for the analysis of triadimefon and ethofumesate from dislodgeable foliar residues on turfgrass by solid-phase extraction and in-vial elution.

    Science.gov (United States)

    Runes, H B; Jenkins, J J; Field, J A

    1999-08-01

    Triadimefon, a fungicide, and ethofumesate, an herbicide, are commonly applied to turfgrass in the Pacific Northwest, resulting in foliar residues. A simple and rapid method was developed to determine triadimefon and ethofumesate concentrations from dislodgeable foliar residues on turfgrass. Turfgrass samples were washed, and wash water containing surfactant (a 0.126% solution) was collected for residue analysis. This analytical method utilizes a 25 mm C(8) Empore disk and in-vial elution to quantitatively determine triadimefon and ethofumesate in 170 mL aqueous samples. The analytes were eluted by placing the disk in a 2 mL autosampler vial with 980 microL of ethyl acetate and 20 microL of 2-chlorolepidine, the internal standard, for analysis by GC/MS. The method quantitation limits are 0.29 microg/L for ethofumesate and 0.59 microg/L for triadimefon. The method detection limits are 0.047 microg/L and 0.29 microg/L for ethofumesate and triadimefon, respectively. Concentrations of triadimefon and ethofumesate from dislodgeable foliar residues from a field study are reported.

  2. A case of Z/E-isomers elution order inversion caused by cosolvent percentage change in supercritical fluid chromatography.

    Science.gov (United States)

    Pokrovskiy, Oleg I; Ustinovich, Konstantin B; Usovich, Oleg I; Parenago, Olga O; Lunin, Valeriy V; Ovchinnikov, Denis V; Kosyakov, Dmitry S

    2017-01-06

    A case of elution order inversion caused by cosolvent percentage change in supercritical fluid chromatography was observed and investigated in some detail. Z- and E-isomers of phenylisobutylketone oxime experience an elution order reversal on most columns if the mobile phase consists of CO 2 and alcohol. At lower percentages of alcohol Z-oxime is retained less, somewhere at 2-5% coelution occurs and at larger cosolvent volume elution order reverses - Z-oxime is eluted later than E-oxime. We suppose inversion with CO 2 -ROH phases happens due to a shift in balance between two main interactions governing retention. At low ROH percentages stationary phase surface is only slightly covered by ROH molecules so oximes primarily interact with adsorption sites via hydrogen bond formation. Due to intramolecular sterical hindrance Z-oxime is less able to form hydrogen bonds and consequently is eluted first. At higher percentages alcohols occupy most of strong hydrogen bonding sites on silica surface thus leaving non-specific electrostatic interactions predominantly responsible for Z/E selectivity. Z-oxime has a much larger dipole moment than E-oxime and at these conditions it is eluted later. Additional experimental data with CO 2 -CH 3 CN, hexane-iPrOH and CHF 3 -ROH mobile phases supporting this explanation are presented. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Behavior of phenolic substances in the decaying process of plants. V. Elution of heavy metals with phenolic acids from soil

    Energy Technology Data Exchange (ETDEWEB)

    Shindo, H; Kuwatsuka, S

    1977-01-01

    The relationship between the elution of heavy metals with phenolic substances and the chemical structure of phenolic substances, as well as the interaction between phenolic substances and metals were studied using batch and column methods. The elution of 3 metals (Fe, Al and Mn) with 4 phenolic acids (rho-hydroxybenzoic, salicylic, ..cap alpha..-resorcylic, and protocatechuic acids) and phthalic acid were investigated using 3 different soils. The results are as follows: (1) The elution of heavy metals was largely influenced by the chemical structures of the phenolic acids. Protocatechuic, salicylic, and phthalic acids which had different chelating sites easily extracted iron, aluminum, and manganese from the soils. Hydroxybenzoic and ..cap alpha..-resorcylic acids which had no chelating sites contributed little to the elution process. (2) In many cases protocatechuic acid showed a stronger affinity to iron than to aluminum, but salicylic acid showed the opposite trend. The affinity of phthalic acid to metals was much less than that of both phenolic acids. (3) The elution of heavy metals was also influenced by the soil pH. The amounts of heavy metals eluted with protocatechuic acid increased as the soil pH increased. The amounts eluted with salicylic and phthalic acids increased as the soil pH decreased. (4) The results suggested that chelating phenolics such as protocatechuic and salicylic acids, which were exuded from plant residues or produced during the decaying process of plant residues, eluted heavy metals such as iron, aluminum and manganese from soil particles and accelerated the downward movement of these metal ions.

  4. Effect of Opalescence® bleaching gels on the elution of dental composite components.

    Science.gov (United States)

    Schuster, Lena; Rothmund, Lena; He, Xiuli; Van Landuyt, Kirsten L; Schweikl, Helmut; Hellwig, Elmar; Carell, Thomas; Hickel, Reinhard; Reichl, Franz-Xaver; Högg, Christof

    2015-06-01

    Bleaching treatments can affect on the polymer network of dental composites. This study was performed to evaluate the influence of different bleaching treatments on the elution of composite components. The composites Tetric EvoCeram(®), CLEARFIL™ AP-X, Tetric EvoFlow(®), Filtek™ Supreme XT, Ceram X(®) mono+, Admira and Filtek™ Silorane were treated with the bleaching gels Opalescence PF 15% (PF 15%) for 5h and PF 35% (PF 35%) for 30 min and then stored in methanol and water for 24h and 7 d. The eluates were analyzed by gas chromatography/mass spectrometry (GC/MS). Unbleached specimens were used as control group. A total of 16 different elutable substances have been identified from the investigated composites after bleaching-treatment. Six of them were methacrylates: 1,10-decandioldimethacrylate (DDDMA), 1,12-dodekandioldimethacrylate (DODDMA), ethylenglycoldimethacrylate (EGDMA), 2-hydroxyethylmethacrylate (HEMA), triethylenglycoldimethacrylate (TEGDMA) and urethandimethacrylate (UDMA). Compared with the unbleached controls the composites Tetric EvoCeram(®), CLEARFIL™ AP-X and Tetric EvoFlow(®) showed a reduced elution of UDMA, TEGDMA and HEMA after bleaching-treatment. Compared with the unbleached controls an increase elution of UDMA, DMABEE, BPA and TEGDMA for the composites Filtek™ Supreme XT, Ceram X(®) mono+, Admira and Filtek™ Silorane after bleaching-treatment has been detected. The highest concentration of UDMA was 0.01 mmol/l (Tetric EvoCeram(®), water, 24h, controls), the highest concentration of TEGDMA was 0.28 mmol/l (CLEARFIL™ AP-X, water, 7 d, controls), the highest concentration of HEMA was 0.74 mmol/l (Tetric EvoFlow(®), methanol, 7 d, PF 35%), the highest concentration of DMABEE was 0.10 mmol/l (Ceram X(®) mono+, water, 7 d, PF 35%) and the highest concentration of BPA was 0.01 mmol/l (Admira, methanol, 7 d, controls). Bleaching treatments can lead to a reduced or an increased elution of substances from the dental composites

  5. Effect of Opalescence(®) bleaching gels on the elution of bulk-fill composite components.

    Science.gov (United States)

    Schuster, Lena; Reichl, Franz-Xaver; Rothmund, Lena; He, Xiuli; Yang, Yang; Van Landuyt, Kirsten L; Kehe, Kai; Polydorou, Olga; Hickel, Reinhard; Högg, Christof

    2016-02-01

    Bleaching treatments can affect release of components from conventional composites. In this continuing study the influence of two different bleaching gels on the elution of bulk-fill composite components was investigated. The composites Tetric EvoCeram(®) Bulk Fill, QuiXFil™ and X-tra fil were treated with the bleaching gels Opalescence PF 15% (PF 15%) for 5 h and PF 35% (PF 35%) for 30 min and then stored in methanol and water for 24 h and 7 d. The eluates were analyzed by gas chromatography/mass spectrometry (GC/MS). Unbleached specimens were used as control group. A total of 7 different elutable substances have been identified from the investigated composites after bleaching-treatment. Three of them were methacrylates: 2-hydroxyethyl methacrylate (HEMA), triethylene glycol dimethacrylate (TEGDMA) and trimethylolpropane trimethacrylate (TMPTMA). Compared to the unbleached controls an increase in elution after PF 15%-treatment of following compounds was found: HEMA (Tetric EvoCeram(®) Bulk Fill), TEGDMA (QuiXFil™, X-tra fil) and 4-N,N-dimethylaminobenzoic acid butyl ethoxy ester (DMABEE) (Tetric EvoCeram(®) Bulk Fill, QuiXFil™, X-tra fil). Following compounds showed a reduction in elution after PF 35%-treatment compared to controls: TEGDMA (QuiXFil™) and DMABEE (Tetric EvoCeram(®) Bulk Fill). The highest concentration of HEMA was 0.22 mmol/l (Tetric EvoCeram(®) Bulk Fill, methanol, 7 d, PF 15%), the highest concentration of TEGDMA was 0.3 mmol/l (X-tra fil, water, 7 d, PF 15%) and the highest concentration of DMABEE was 0.05 mmol/l (QuiXFil™, water, 7 d, PF 35%). PF 15% and PF 35% can lead to reduced and/or increased elution of some bulk-fill components, compared to unbleached bulk-fill composites. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Clinical benefits of drug-eluting stent implantation in septuagenarians with coronary artery disease

    International Nuclear Information System (INIS)

    Fang Yuehua; Shen Weifeng; Zhang Ruiyan; Zhang Jiansheng; Hu Jian; Zhang Xian; Zheng Aifang

    2005-01-01

    Objective: This study evaluated the safety and long-term outcomes of drug-eluting stents in septuagenarians with coronary artery disease. Methods: Two hundred and thirty-nine consecutive patients with coronary artery disease underwent drug-eluting stenting, including 88 patients aged ≥70 years (group A) and 151 aged <70 years (group B). Baseline clinical characteristics, procedural success rate, occurrence of cardiac events during follow-up were recorded and compared between the two groups. Results: Procedural success rate and complications were similar for the two groups. During follow-up, group A had higher recurrence rate of chest pain than group B (23.9% vs. 7.3%, P<0.001), and occurrence of cardiac events was higher in group A than in group B (5.7% vs. 2.7%, P<0.296). There was no significant difference in the frequency of restenosis between the two groups. Conclusions: Drug-eluting stent implantation for septuagenarians with coronary artery disease is safe but may have more recurrence of angina than younger ones during long-term follow-up. (authors)

  7. Determination of phenolic compounds using high-performance liquid chromatography with Ce4+-Tween 20 chemiluminescence detection

    International Nuclear Information System (INIS)

    Cui Hua; Zhou Jian; Xu Feng; Lai Chunze; Wan Guohui

    2004-01-01

    A novel method for the simultaneous determination of phenolic compounds such as salicylic acid, resorcinol, phloroglucinol, p-hydroxybenzoic acid, 2,4-dihydroxybenzoic acid, and m-nitrophenol by high-performance liquid chromatography (HPLC) coupled with chemiluminescence (CL) detection was developed. The procedure was based on the chemiluminescent enhancement by phenolic compounds of the cerium(IV)-Tween 20 system in a sulfuric acid medium. The separation was carried out with an isocratic elution or with a gradient elution using a mixture of methanol and 1.5% acetic acid. For six phenolic compounds, the detection limits (3σ) were in the range 1.40-5.02 ng/ml and the relative standard deviations (n=11) for the determination of 0.1 μg/ml compounds were in the range 1.9-2.9%. The CL reaction was well compatible with the mobile phase of HPLC, no baseline drift often occurred in HPLC-CL detection was observed with a gradient elution. The method has been successfully applied to the determination of salicylic acid and resorcinol in Dermatitis Clear Tincture and p-hydroxybenzoic acid in apple juices

  8. Sequential Elution Interactome Analysis of the Mind Bomb 1 Ubiquitin Ligase Reveals a Novel Role in Dendritic Spine Outgrowth*

    Science.gov (United States)

    Mertz, Joseph; Tan, Haiyan; Pagala, Vishwajeeth; Bai, Bing; Chen, Ping-Chung; Li, Yuxin; Cho, Ji-Hoon; Shaw, Timothy; Wang, Xusheng; Peng, Junmin

    2015-01-01

    The mind bomb 1 (Mib1) ubiquitin ligase is essential for controlling metazoan development by Notch signaling and possibly the Wnt pathway. It is also expressed in postmitotic neurons and regulates neuronal morphogenesis and synaptic activity by mechanisms that are largely unknown. We sought to comprehensively characterize the Mib1 interactome and study its potential function in neuron development utilizing a novel sequential elution strategy for affinity purification, in which Mib1 binding proteins were eluted under different stringency and then quantified by the isobaric labeling method. The strategy identified the Mib1 interactome with both deep coverage and the ability to distinguish high-affinity partners from low-affinity partners. A total of 817 proteins were identified during the Mib1 affinity purification, including 56 high-affinity partners and 335 low-affinity partners, whereas the remaining 426 proteins are likely copurified contaminants or extremely weak binding proteins. The analysis detected all previously known Mib1-interacting proteins and revealed a large number of novel components involved in Notch and Wnt pathways, endocytosis and vesicle transport, the ubiquitin-proteasome system, cellular morphogenesis, and synaptic activities. Immunofluorescence studies further showed colocalization of Mib1 with five selected proteins: the Usp9x (FAM) deubiquitinating enzyme, alpha-, beta-, and delta-catenins, and CDKL5. Mutations of CDKL5 are associated with early infantile epileptic encephalopathy-2 (EIEE2), a severe form of mental retardation. We found that the expression of Mib1 down-regulated the protein level of CDKL5 by ubiquitination, and antagonized CDKL5 function during the formation of dendritic spines. Thus, the sequential elution strategy enables biochemical characterization of protein interactomes; and Mib1 analysis provides a comprehensive interactome for investigating its role in signaling networks and neuronal development. PMID:25931508

  9. Progress in the study of drug-eluting intra-stent thrombosis

    International Nuclear Information System (INIS)

    Guo Zhifu; Zheng Xing; Qin Yongwen

    2007-01-01

    Durg-eluting stent has been regarded as the milestone in the history of PCI for their efficiency in the prevention of coronary arterial restenosis after percutaneous coronary intervention. But unfortunately intra-stent thrombosis continues to be a serious complication of contemporary DES use. The incidence of drug-eluting stents thrombosis is at least not lower than that of bare metal stents at present. The clinical consequences of stent thrombosis are frequently catastrophic, including death in 40% to 50% of the cases or major myocardial infarction in 60% to 70%. Premature discontinuation of standard antiplatelet therapy is by far the most important predictor of stent thrombosis with DES and other predictors included renal failure, diabetes, bifurcation lesions, multiple lesions or multivessel disease, long stents, female, advanced age, stent underexpansion and residual stenosis etc. The delayed endothelialization may be the underling mechanism of DES thrombosis. (authors)

  10. Bioabsorbable polymer-coated sirolimus-eluting stent implantation preserves coronary vasomotion: A DESSOLVE II trial sub-study.

    Science.gov (United States)

    Rusinaru, Dan; Vrolix, Mathias; Verheye, Stefan; Chowdhary, Saqib; Schoors, Danny; Di Mario, Carlo; Desmet, Walter; Donohoe, Dennis J; Ormiston, John A; Knape, Charlene; Bezerra, Hiram; Lansky, Alexandra; Wijns, William

    2015-12-01

    We studied coronary vasomotion in patients treated with the Mistent(®) absorbable polymer sirolimus-eluting stent (APSES) and in patients implanted with the Endeavor(®) zotarolimus-eluting stent (ZES). First generation (1st-gen) drug-eluting stents (DES) induce persistent vasomotor dysfunction in the treated coronary artery. It is unknown whether and to what extent the implantation of an absorbable polymer DES impairs coronary vasomotion. This sub-study of the DESSOLVE II trial included 19 APSES Mistent(®) and 10 ZES Endeavor(®) patients. Incremental atrial pacing and quantitative coronary angiography were used to assess vasomotion proximal and distal to the stent and in a reference segment at 9 months after implantation. Percent changes in vessel diameter with pacing versus baseline were calculated and compared. Vasomotor response of the APSES group was also compared with changes observed in a historical group of 17 patients implanted with a 1st-gen sirolimus-eluting stent (SES). Normal vasomotion (vasodilatation) was preserved and of comparable magnitude in the APSES and in the ZES group both proximally (P = 0.34) and distally (P = 0.38) to the stent. This finding was not observed in the 1st-gen SES group showing marked pacing-induced vasoconstriction at both stent edges (P absorbable polymer sirolimus-eluting stent is associated with preserved coronary vasomotion, comparable to that observed after implantation of the Endeavor(®) ZES, and distinct from 1st-gen SES which induce coronary vasomotor dysfunction. © 2015 Wiley Periodicals, Inc.

  11. A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial

    NARCIS (Netherlands)

    Serruys, Patrick W.; Chevalier, Bernard; Dudek, Dariusz; Cequier, Angel; Carrié, Didier; Iniguez, Andres; Dominici, Marcello; van der Schaaf, René J.; Haude, Michael; Wasungu, Luc; Veldhof, Susan; Peng, Lei; Staehr, Peter; Grundeken, Maik J.; Ishibashi, Yuki; Garcia-Garcia, Hector M.; Onuma, Yoshinobu

    2015-01-01

    Despite rapid dissemination of an everolimus-eluting bioresorbable scaffold for treatment for coronary artery disease, no data from comparisons with its metallic stent counterpart are available. In a randomised controlled trial we aimed to compare an everolimus-eluting bioresorbable scaffold with an

  12. Speciation of selenoamino acids, selenonium ions and inorganic selenium by ion exchange HPLC with mass spectrometric detection and its application to yeast and algae

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Hansen, M.; Fan, T.

    2001-01-01

    Cation and anion exchange HPLC were used to separate a mixture of 12 selenium species comprising selenoamino acids, selenonium ions and inorganic selenium. The cationic species were separated from each other and from the co-injected anions using a cation exchange column with gradient elution...... by aqueous pyridinium formate at pH similar to 3 as the mobile phase. The anionic species were separated using an anion exchange column with isocratic elution by an aqueous salicylate-TRIS mobile phase at pH 8.5. The separated selenium species were detected as Se-80 by ICP-dynamic reaction cell (DRC...... acid extract of Chlorella algae contained dimethylselenonium propionate (DMSeP), which was verified by HPLC-ES-MS. Se-allylselenocysteine and selenoethionine was detected at the low ng g(-1) concentration level based on co-chromatography with the standard substances spiked to the algal extract....

  13. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    International Nuclear Information System (INIS)

    Veres, M.; Beiler, B.; Himics, L.; Tóth, S.; Koós, M.

    2010-01-01

    Many areas of modern medicine are almost unimaginable without the use of different kinds of implants. They used as replacements, supports, auxiliary devices etc. for various parts or functions of the body. Their use has many advantages, however there could be some drawbacks too, like the possibility of rejection, inflammation and other side-effects. Many of these drawbacks are directly related to the materials used for the implant fabrication. Coatings are widely used to eliminate the unwanted effects appearing after the implantation. In addition to the protection and separation of tissues from the implant material they could also enhance the functionality and the acceptance of the artificial device and also promote the regeneration of the tissues after the intervention. Drug-eluting coatings are a good example for the latter. By delivery and controlled elution of drugs they could actively suppress inflammatory reactions, allergy and rejection of the implant, and their activity is localized to the place where these effects could mainly occur – to the region of the implant. This project is aimed to develop a drug-eluting porous polymer coating by radiation induced polymerization that can be used in different medical implants. The primary objects for this research are coronary stents however these porous layers could have perspective in other types of medical devices too. The main objectives are to develop a method for coating the surface of medical grade metallic alloy wires, plates and tubes with a porous polymer nanocomposite layer prepared by radiation induced polymerization and to characterize the obtained coatings

  14. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Veres, M.; Beiler, B.; Himics, L.; Tóth, S.; Koós, M., E-mail: vm@szfki.hu [Hungarian Academy of Sciences, Research Institute for Solid State Physics and Optics, Department of Laser Applications, Konkoly Thege Miklós ut 29-33, 1121 Budapest, P.O. Box 49, 1525 Budapest (Hungary)

    2010-07-01

    Many areas of modern medicine are almost unimaginable without the use of different kinds of implants. They used as replacements, supports, auxiliary devices etc. for various parts or functions of the body. Their use has many advantages, however there could be some drawbacks too, like the possibility of rejection, inflammation and other side-effects. Many of these drawbacks are directly related to the materials used for the implant fabrication. Coatings are widely used to eliminate the unwanted effects appearing after the implantation. In addition to the protection and separation of tissues from the implant material they could also enhance the functionality and the acceptance of the artificial device and also promote the regeneration of the tissues after the intervention. Drug-eluting coatings are a good example for the latter. By delivery and controlled elution of drugs they could actively suppress inflammatory reactions, allergy and rejection of the implant, and their activity is localized to the place where these effects could mainly occur – to the region of the implant. This project is aimed to develop a drug-eluting porous polymer coating by radiation induced polymerization that can be used in different medical implants. The primary objects for this research are coronary stents however these porous layers could have perspective in other types of medical devices too. The main objectives are to develop a method for coating the surface of medical grade metallic alloy wires, plates and tubes with a porous polymer nanocomposite layer prepared by radiation induced polymerization and to characterize the obtained coatings.

  15. Safety and efficacy of low-dose paclitaxel utilizing the cobra-P drug-eluting stent system with a novel biodegradable coating in de novo coronary lesions: The PLUS-ONE first-in-man study

    International Nuclear Information System (INIS)

    Calderas, Carlos; Condado, Jose Francisco; Condado, Jose Antonio; Flores, Alejandra; Mueller, Amy; Thomas, Jack; Nakatani, Daisaku; Honda, Yasuhiro; Waseda, Katsuhisa; Fitzgerald, Peter

    2014-01-01

    Background: The Cobra-P drug-eluting stent (DES) system consists of cobalt chromium alloy with bio-absorbable siloxane sol–gel matrix coating that elutes low dose paclitaxel within 6 months. The aim of this first-in-man trial was to evaluate the safety and performance of 2 doses of the Cobra-P DES. Methods: A total of 60 lesions (54 patients) were sequentially assigned to 2 different paclitaxel doses: group A (3.7 μg/18 mm, n = 30) or group B (8 μg/18 mm, n = 30). The primary endpoint was MACE at 4 months defined as cardiac death, myocardial infarction, and target lesion revascularization. Results: Patient and lesion characteristics were matched between the 2 groups except for male sex. MACE at 4 months was 3.3% and 0% respectively (P = 1.000) and at 1-year follow-up remained unchanged. In-stent late loss at 4 months was similar in both groups (0.36 ± 0.30 mm and 0.34 ± 0.20 mm P = .773). Conclusions: In this FIM study, implantation of the Cobra-P low dose paclitaxel-eluting stent with a bioabsorbable sol–gel coating was proven to be feasible and safe. Moderate neointimal proliferation was observed as well as an acceptable MACE rate up to 1 year

  16. Safety and efficacy of low-dose paclitaxel utilizing the cobra-P drug-eluting stent system with a novel biodegradable coating in de novo coronary lesions: the PLUS-ONE first-in-man study.

    Science.gov (United States)

    Calderas, Carlos; Condado, Jose Francisco; Condado, Jose Antonio; Flores, Alejandra; Mueller, Amy; Thomas, Jack; Nakatani, Daisaku; Honda, Yasuhiro; Waseda, Katsuhisa; Fitzgerald, Peter

    2014-01-01

    The Cobra-P drug-eluting stent (DES) system consists of cobalt chromium alloy with bio-absorbable siloxane sol-gel matrix coating that elutes low dose paclitaxel within 6 months. The aim of this first-in-man trial was to evaluate the safety and performance of 2 doses of the Cobra-P DES. A total of 60 lesions (54 patients) were sequentially assigned to 2 different paclitaxel doses: group A (3.7 μg/18mm, n=30) or group B (8 μg/18mm, n=30). The primary endpoint was MACE at 4 months defined as cardiac death, myocardial infarction, and target lesion revascularization. Patient and lesion characteristics were matched between the 2 groups except for male sex. MACE at 4 months was 3.3% and 0% respectively (P=1.000) and at 1-year follow-up remained unchanged. In-stent late loss at 4 months was similar in both groups (0.36 ± 0.30mm and 0.34 ± 0.20mm P=.773). In this FIM study, implantation of the Cobra-P low dose paclitaxel-eluting stent with a bioabsorbable sol-gel coating was proven to be feasible and safe. Moderate neointimal proliferation was observed as well as an acceptable MACE rate up to 1 year. © 2014.

  17. Safety and efficacy of low-dose paclitaxel utilizing the cobra-P drug-eluting stent system with a novel biodegradable coating in de novo coronary lesions: The PLUS-ONE first-in-man study

    Energy Technology Data Exchange (ETDEWEB)

    Calderas, Carlos [Instituto de Clinicas Urologia Tamanaco, Caracas (Venezuela, Bolivarian Republic of); Condado, Jose Francisco; Condado, Jose Antonio [Hospital Centro Medico de Caracas y Hospital Miguel Perez Carreno, Caracas (Venezuela, Bolivarian Republic of); Flores, Alejandra [Instituto de Clinicas Urologia Tamanaco, Caracas (Venezuela, Bolivarian Republic of); Mueller, Amy; Thomas, Jack [Medlogics Device Corporation, Santa Rosa, CA (United States); Nakatani, Daisaku; Honda, Yasuhiro; Waseda, Katsuhisa [Stanford University, Stanford, CA (United States); Fitzgerald, Peter, E-mail: crci-cvmed@stanford.edu [Stanford University, Stanford, CA (United States)

    2014-01-15

    Background: The Cobra-P drug-eluting stent (DES) system consists of cobalt chromium alloy with bio-absorbable siloxane sol–gel matrix coating that elutes low dose paclitaxel within 6 months. The aim of this first-in-man trial was to evaluate the safety and performance of 2 doses of the Cobra-P DES. Methods: A total of 60 lesions (54 patients) were sequentially assigned to 2 different paclitaxel doses: group A (3.7 μg/18 mm, n = 30) or group B (8 μg/18 mm, n = 30). The primary endpoint was MACE at 4 months defined as cardiac death, myocardial infarction, and target lesion revascularization. Results: Patient and lesion characteristics were matched between the 2 groups except for male sex. MACE at 4 months was 3.3% and 0% respectively (P = 1.000) and at 1-year follow-up remained unchanged. In-stent late loss at 4 months was similar in both groups (0.36 ± 0.30 mm and 0.34 ± 0.20 mm P = .773). Conclusions: In this FIM study, implantation of the Cobra-P low dose paclitaxel-eluting stent with a bioabsorbable sol–gel coating was proven to be feasible and safe. Moderate neointimal proliferation was observed as well as an acceptable MACE rate up to 1 year.

  18. Methods for eluting radiocesium from zeolite ion exchange material in a column in the TMI-2 reactor containment building

    International Nuclear Information System (INIS)

    Knauer, J.B.; Campbell, D.O.; Collins, E.D.; King, L.J.

    1982-07-01

    Two alternative procedures were evaluated at Oak Ridge National Laboratory for potential use in eluting the radiocesium from Linde Ionsiv IE-95 zeolite in the pushcart ion exchange column in the TMI-2 containment building. The elution mechanism was iosotopic exchange of the radiocesium with stable cesium. Small zeolite ion exchange columns that had been loaded during ORNL tests of the Submerged Demineralizer System (SDS) flowsheet were eluted during these tests. One column was eluted using 0.25 M CsNO 3 , and a second column was eluted using 0.25 M CsH 2 BO 3 . Both eluent solutions were effective for removing the cesium. The 0.25 CsNO 3 eluent removed approx. 91% of the 137 Cs in 20 bed volumes and approx. 92% in 37.5 bed volumes. The 0.25 M CsH 2 BO 3 eluent removed approx. 82% of the 137 Cs in 20 bed volumes and approx. 85% in 40 bed volumes. In both cases, the radiation levels on the columns were reduced by a factor of approx. 30

  19. Drug-eluting versus bare-metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kaiser, Christoph; Galatius, Soeren; Erne, Paul

    2010-01-01

    Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether...

  20. Vývoj HPLC metody pro stanovení vitaminu E v přípravku geladrink

    OpenAIRE

    Švestková, Petra

    2010-01-01

    A HPLC method was developed for the determination of content of vitamine E acetate in preparation Geladrink Forte pulverized drink - pineapple. The method is based on using Chromolith Performance RP-18e column (100 x 4.6 mm) and UV detection at 290 nm. The vitamine E acetate was separated in the presence of internal standard tocol from ballast matrix. It was used isocratic elution of the mobile phase methanol:water (98:2) at a flow-rate of 1.5 ml/min. There was temperature 30 řC during the me...

  1. Determination of 2-naphthylamine in urine by a novel reversed-phase high-performance liquid chromatography method

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1992-01-01

    A high-performance liquid chromatographic method for the determination of 2-naphthylamine in urine using fluorescence detection was developed. The method validation analysis showed the method to be in analytical control, i.e. the distribution of the difference between the observed and true values...... of the method evaluation samples did not deviate significantly from the normal distribution. The recovery of the method was 85%. The entire run time of chromatography was 10 min using isocratic elution (acetonitrile-water, 35:65), and the retention time for 2-naphthylamine was 5.8 min. The relative short time...

  2. The study of drug eluting biodegradable intravascular stent with antiproliferation agent-paclitaxel in preventing vascular restenosis

    International Nuclear Information System (INIS)

    Xiao Yueyong; Zhang Jinshan; Cui Fuzhai; Meng Bo

    2004-01-01

    Objective: To define the effect of drug eluting BIS with antiproliferation agent-paclitaxel in preventing vascular restenosis. Methods: Bare BIS and drug BIS with 60 μg paclitaxel were prepared. Both types of the BIS were implanted into the infrarenal restenosis aortas in canine models, and the animals were euthanized 6 weeks after implantation for histopathological, morphometric and immunohistochemical assessment. Results: The mean lumen area of bare BIS group was (77 586.5 ± 66.0) μm 2 , and lumen of paclitaxel eluting BIS group was (113 435.9 ±71.0) μm 2 . The mean neointima area of bare BIS group was (24 803 ± 56) μm 2 , and paclitaxel eluting BIS group was (12 931 ± 63) μm 2 . The PCNA-positive ratio was (38 ± 15)% in bare BIS group and (11 ± 0.31)% in paclitaxel eluting BIS group. The statistically significant difference between the two groups were noted (P<0.01). Conclusion: BIS as a vehicle of loading and releasing drugs could significantly inhibit the VSMC and neointimal hyperplasia with antiproliferation agent-paclitaxel. BIS is a promising and new strategy in preventing the restenosis

  3. THE BEHAVIOR OF SOLUBLE METALS ELUTED FROM Ni/Fe-BASED ALLOY REACTORS AFTER HIGH-TEMPERATURE AND HIGH-PRESSURE WATER PROCESS

    Directory of Open Access Journals (Sweden)

    M. Faisal

    2012-05-01

    Full Text Available The behavior of heavy metals eluted from the wall of Ni/Fe-based alloy reactors after high-temperature and high-pressure water reaction were studied at temperatures ranging from 250 to 400oC. For this purpose, water and cysteic acid were heated in two reactor materials which are SUS 316 and Inconel 625. Under the tested conditions, the erratic behaviors of soluble metals eluted from the wall of Ni/Fe-based alloy in high temperature water were observed. Results showed that metals could be eluted even at a short contact time. The presence of air also promotes elution at sub-critical conditions. At sub-critical conditions, a significant amount of Cr was extracted from SUS 316, while only traces of Ni, Fe, Mo and Mn were eluted. In contrast, Ni was removed in significant amounts compared to Cr when Inconel 625 was tested. It was observed that eluted metals tend to increased under acidic conditions and most of those metals were over the limit of WHO guideline for drinking water. The results are significant both on the viewpoint of environmental regulation on disposal of wastes containing heavy metals, toxicity of resulting product and catalytic effect on a particular reaction.

  4. DNA elution from buccal cells stored on Whatman FTA Classic Cards using a modified methanol fixation method.

    Science.gov (United States)

    Johanson, Helene C; Hyland, Valentine; Wicking, Carol; Sturm, Richard A

    2009-04-01

    We describe here a method for DNA elution from buccal cells and whole blood both collected onto Whatman FTA technology, using methanol fixation followed by an elution PCR program. Extracted DNA is comparable in quality to published Whatman FTA protocols, as judged by PCR-based genotyping. Elution of DNA from the dried sample is a known rate-limiting step in the published Whatman FTA protocol; this method enables the use of each 3-mm punch of sample for several PCR reactions instead of the standard, one PCR reaction per sample punch. This optimized protocol therefore extends the usefulness and cost effectiveness of each buccal swab sample collected, when used for nucleic acid PCR and genotyping.

  5. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: 3-year follow-up of the randomized DEDICATION (Drug Elution and Distal Protection in Acute Myocardial Infarction) Trial

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Kelbaek, Henning; Thuesen, Leif

    2010-01-01

    The purpose of this study was to compare long-term clinical outcomes after implantation of drug-eluting stents (DES) and bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI).......The purpose of this study was to compare long-term clinical outcomes after implantation of drug-eluting stents (DES) and bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI)....

  6. Multivariate analysis of elution parameters for RP-HPLC with charged aerosol detection of sucrose caprate regioisomers

    DEFF Research Database (Denmark)

    Lie, Aleksander; Pedersen, Lars Haastrup

    2012-01-01

    and Environmental Engineering, Aalborg University, Denmark Sugar fatty acid monoesters have been shown to possess antibiotic and insecticidal properties. The physical and chemical properties of sugar fatty acid esters depend on the saccharide moiety, fatty acid chain length, and both position and degree...... for sucrose caprate regioisomers. As a sensitive method based on mass detection, charged aerosol detection was used. The investigation was conducted using design-of-experiments (DOE) methodology for development and prediction of elution strategies. The elution profiles were described by a number of important......BIOCAT2012, Hamburg University of Technology Book of Abstracts, p290 ISBN 987-3-941492 L73) Multivariate analysis of elution parameters for RP-HPLC with charged aerosol detection of sucrose caprate regioisomers Aleksander Lie and Lars Haastrup Pedersen Department of Biotechnology, Chemistry...

  7. Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

    Science.gov (United States)

    Waseda, Katsuhisa; Ako, Junya; Yamasaki, Masao; Koizumi, Tomomi; Sakurai, Ryota; Hongo, Yoichiro; Koo, Bon-Kwon; Ormiston, John; Worthley, Stephen G; Whitbourn, Robert J; Walters, Darren L; Meredith, Ian T; Fitzgerald, Peter J; Honda, Yasuhiro

    2011-06-01

    Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; Ppolymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.

  8. Disappearing and reappearing differences in drug-eluting stent use by race.

    Science.gov (United States)

    Federspiel, Jerome J; Stearns, Sally C; Reiter, Kristin L; Geissler, Kimberley H; Triplette, Matthew A; D'Arcy, Laura P; Sheridan, Brett C; Rossi, Joseph S

    2013-04-01

    Drug-eluting coronary stents (DES) rapidly dominated the marketplace in the United States after approval in 2003, but utilization rates were initially lower among African American patients. We assess whether racial differences persisted as DES diffused into practice. Medicare claims data were used to identify coronary stenting procedures among elderly patients with acute coronary syndromes (ACS). Regression models of the choice of DES versus bare mental stent controlled for demographics, ACS type, co-morbidities and hospital characteristics. Diffusion was assessed in the short run (2003-2004) and long run (2007), with the effect of race calculated to allow for time-varying effects. The sample included 381,887 Medicare beneficiaries treated with stent insertion; approximately 5% were African American. Initially (May 2003-February 2004), African American race was associated with lower DES use compared to other races (44.3% versus 46.5%, P differences were not significant (79.8% versus 80.3%, P = 0.45). Subsequent concerns regarding DES safety caused reductions in DES use, with African Americans having lower use than other racial groups in 2007 (63.1% versus 65.2%, P differences in race reflect decisions regarding treatment appropriateness. © 2011 Blackwell Publishing Ltd.

  9. Endeavour zotarolimus-eluting stent reduces stent thrombosis and improves clinical outcomes compared with cypher sirolimus-eluting stent : 4-year results of the PROTECT randomized trial

    NARCIS (Netherlands)

    Wijns, William; Steg, Ph. Gabriel; Mauri, Laura; Kurowski, Volkhard; Parikh, Keyur; Gao, Runlin; Bode, Christoph; Greenwood, John P.; Lipsic, Erik; Alamgir, Farqad; Rademaker-Havinga, Tessa; Boersma, Eric; Radke, Peter; van Leeuwen, Frank; Camenzind, Edoardo

    2014-01-01

    Aims To compare the long-term clinical safety between two drug-eluting stents with different healing characteristics in the Patient Related Outcomes with Endeavour (E-ZES) vs. Cypher (C-SES) Stenting Trial (PROTECT). At 3 years, there was no difference in the primary outcome of definite or probable

  10. Multifunctional surfaces with biomimetic nanofibres and drug-eluting micro-patterns for infection control and bone tissue formation

    Directory of Open Access Journals (Sweden)

    XN Chen

    2012-09-01

    Full Text Available For long-term orthopaedic implants, the creation of a surface that is repulsive to bacteria while adhesive to tissue cells represents a promising strategy to control infection. To obtain such multifunctional surfaces, two possible approaches were explored to incorporate a model antibiotic, rifampicin (Rf, into the osteogenic polycaprolactone (PCL/chitosan (CHS biomimetic nanofibre meshes by (1 blending Rf into the electrospinning solutions and then electrospinning into nanofibres (i.e., Rf-incorporating fibres, or (2 depositing Rf-containing poly(D,L-lactic-co-glycolic acid (PLGA micro-patterns onto the PCL/chitosan nanofibre meshes via ink-jet printing (i.e., Rf-eluting micro-pattern/fibre. Rapid release of Rf from both meshes was measured even though a relatively slower release rate was obtained from the Rf-eluting micro-pattern ones. Antibacterial assay with Staphylococcus epidermidis showed that both mesh surfaces could effectively kill bacteria and prevent biofilm formation. However, only Rf-eluting micro-pattern meshes favoured the attachment, spreading and metabolic activity of preosteoblasts in the cell culture study. Furthermore, the Rf-eluting micro-pattern meshes could better support the osteogenic differentiation of preosteoblasts by up-regulating the gene expression of bone markers (type I collagen and alkaline phosphatase. Clearly, compared to Rf-incorporating nanofibre meshes, Rf-eluting micro-patterns could effectively prevent biofilm formation without sacrificing the osteogenic properties of PCL/chitosan nanofibre surfaces. This finding provides an innovative avenue to design multifunctional surfaces for enhancing bone tissue formation while controlling infection.

  11. Dynamics of silver elution from functionalised antimicrobial nanofiltration membranes.

    Science.gov (United States)

    Choudhari, S; Habimana, O; Hannon, J; Allen, A; Cummins, E; Casey, E

    2017-07-01

    In an effort to mitigate biofouling on thin film composite membranes such as nanofiltration and reverse osmosis, a myriad of different surface modification strategies has been published. The use of silver nanoparticles (Ag-NPs) has emerged as being particularly promising. Nevertheless, the stability of these surface modifications is still poorly understood, particularly under permeate flux conditions. Leaching or elution of Ag-NPs from the membrane surface can not only affect the antimicrobial characteristics of the membrane, but could also potentially present an environmental liability when applied in industrial-scale systems. This study sought to investigate the dynamics of silver elution and the bactericidal effect of an Ag-NP functionalised NF270 membrane. Inductively coupled plasma-atomic emission spectroscopy was used to show that the bulk of leached silver occurred at the start of experimental runs, and was found to be independent of salt or permeate conditions used. Cumulative amounts of leached silver did, however, stabilise following the initial release, and were shown to have maintained the biocidal characteristics of the modified membrane, as observed by a higher fraction of structurally damaged Pseudomonas fluorescens cells. These results highlight the need to comprehensively assess the time-dependent nature of bactericidal membranes.

  12. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    International Nuclear Information System (INIS)

    Han, Dong-Wook; Lee, Jun Jae; Jung, Duk-Young; Park, Jong-Chul; Hyon, Suong-Hyu

    2009-01-01

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-ε-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  13. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dong-Wook [Department of Nanomedical Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 609-735 (Korea, Republic of); Lee, Jun Jae [Division of Advanced Fibro-Science, Kyoto Institute of Technology, Kyoto 606-8585 (Japan); Jung, Duk-Young [Senior Products Industrial Center, Busan Techno-Park, Busan-617-030 (Korea, Republic of); Park, Jong-Chul [Cellbiocontrol Laboratory, Department of Medical Engineering, Yonsei University College of Medicine, Seoul 120-752 (Korea, Republic of); Hyon, Suong-Hyu, E-mail: nanohan@pusan.ac.k, E-mail: biogen@frontier.kyoto-u.ac.j [Department of Medical Simulation Engineering, Institute for Frontier Medical Sciences, Kyoto University, Kyoto 606-8507 (Japan)

    2009-08-15

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-epsilon-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  14. Comparison of paclitaxel- and sirolimus-eluting stents in everyday clinical practice: the SORT OUT II randomized trial

    DEFF Research Database (Denmark)

    Galløe, Anders M; Thuesen, Leif; Kelbaek, Henning

    2008-01-01

    Approval of drug-eluting coronary stents was based on results of relatively small trials of selected patients; however, in routine practice, stents are used in a broader spectrum of patients.......Approval of drug-eluting coronary stents was based on results of relatively small trials of selected patients; however, in routine practice, stents are used in a broader spectrum of patients....

  15. The utilization and performance of poly zirconium chloride (PZC) as chromatographic column for 99mTc generator

    International Nuclear Information System (INIS)

    Wan Anuar Wan Awang; Zulkifli Mohd Hashim; Saaban Kassim

    2004-01-01

    We report on the performance test of column 99m Tc generator utilizing poly zirconium chloride as an adsorbent. Natural molybdenum trioxide was irradiated for 2 hrs at a neutron flux of about 1.5 x 10 12 n/cm 2 /s. A total fourteen generators have been prepared from the experiments. Yield of 99m Tc has been 60-93% and measured 99 Mo content in eluates is 0.20-0.44 %. The adsorption efficiency of 99 Mo on PZC column is between 85 - 92 %. The flow rates from the elution are relatively very poor and take about 5 minutes to finish the elution of 1 ml saline. (author)

  16. Cationic mobility in polystyrene sulfone exchangers - Application to the elution of a cation on an exchange column

    International Nuclear Information System (INIS)

    Menin, Jean-Pierre

    1969-01-01

    The aim of this work is to improve elutions and separations carried out on inorganic exchangers by selective electromigration of the ionic species to be displaced. To do this, it has been found indispensable to make a fundamental study of the mobility of cations in exchangers. As the field for this research we have chosen those organic exchangers whose structure and behaviour with respect to ion-exchange are much better known that in the case of their inorganic equivalents. We have related the idea of the equivalent conductivity to that of the cation mobility in the exchanger, and this has entailed determining the specific conductivity of the exchanger and the cation concentration in the resin. The results obtained have allowed us to draw up a hypothesis concerning the cation migration mechanism in the exchanger. The third part of our work has been the application of the preceding results to an operation on an ion-exchange column, viz. the elution by an acid solution of a single fixed ion, magnesium or strontium. This work has enabled us to show that the electromigration of a cation during its elution can markedly accelerate or retard this elution. (author) [fr

  17. Response rates of hepatocellular carcinoma and hepatic colorectal cancer metastases to drug eluting bead regional liver therapy

    Institute of Scientific and Technical Information of China (English)

    Glenn W. Stambo; Deborah Cragan

    2017-01-01

    Aim: The purpose of this study was to evaluate and compare how hepatocellular carcinoma (HCC) and colorectal metastases respond to LC Bead chemoembolization using doxorubicin and irinotecan. Methods: The authors report their experience with doxorubicin and irinotecan eluting beads to treat 13 patients with primary HCC and 25 patients with colorectal metastases over a 1-year period at a single community based oncology practice. Within the colorectal cancer group they compared irinotecan eluting beads to doxorubicin eluting beads. Results:Nine of the 11 (81.8%) doxorubicin treated HCC patients had either complete response or partial response. All of the HCC lesions showed reduction in size and tumor enhancement and 10/11 (91%) HCC patients were alive at 24 months post treatment. Fisher's exact test revealed that among the 22 with colorectal metastases for whom follow-up data were available, those 11 who were treated with doxorubicin were significantly more likely to demonstrate complete or partial response compared to the 11 in the irinotecan treated group (P < 0.001). Conclusion:Overall, HCC and colon metastasis patients clearly demonstrated the effectiveness of drug eluting beads with 91% of the HCC patients alive 24 months after treatment.

  18. Transarterial chemoembolization with drug-eluting beads for hepatocellular carcinoma: its research progress

    International Nuclear Information System (INIS)

    Zhao Yan; Han Guohong; Bai Wei; Fan Daiming

    2012-01-01

    Transarterial chemoembolization (TACE) has been the main treatment for patients with intermediate-stage hepatocellular carcinoma (HCC). However, the clinical application of TACE is limited due to the technical deficiencies, such as uncontrolled local drug delivery and systemic toxicity. Recently, the new drug-eluting beads (DEB), loading with doxorubicin, have be used in the TACE procedures. This new technique can not only maintain the local drug level for quite a long time and thus get a higher objective response, but also decrease the systemic toxicity. Transarterial chemoembolization with drug-eluting beads (DEB-TACE) have already been widely used abroad, and more related clinical trials are underway to clarify its advantages. This paper aims to make a comprehensive review in the respects of its characteristics and the latest research progress in DEB-TACE. (authors)

  19. Development of Direct Reversed-Phase High Performance liquid chromatographic method for quantitative determination of gabapentin in pharmaceutical dosage

    International Nuclear Information System (INIS)

    Hassan, W.; Zaman, B.; Rahman, S.; Rahman, A.U.; Ali, N.; Mohammadzai, I.U.

    2012-01-01

    The objective of the present work was to develop and validate a rapid analytical method for quantitative determination of Gabapentin in pharmaceutical dosage tablets and capsules. An accurate, simple, and sensitive reversed-phase high performance liquid chromatographic (HPLC) method, UV detection at 215 nm and flow rate at 1.0 ml/min has been developed. Isocratic elution was used instead of gradient elution to reduce the time and cost of serial analysis. The mobile phase was a mixture of water and methanol (HPLC grade). The retention time (Rt) of Gabapentin was 4.681 +- 0.013 minutes. Recovery, Precision, accuracy, and linearity were determined for the stated method. The calibration curve was linear and the correlation coefficient was 0.9996. There was no chromatographic interference from other excipients present in dosage form. The method was validated appropriately and successfully used for determination of Gabapentin in Pharmaceutical formulations. (author)

  20. A rapid monitoring method for inorganic arsenic in rice flour using reversed phase-high performance liquid chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Narukawa, Tomohiro; Chiba, Koichi; Sinaviwat, Savarin; Feldmann, Jörg

    2017-01-06

    A new rapid monitoring method by means of high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) following the heat-assisted extraction was developed for measurement of total inorganic arsenic species in rice flour. As(III) and As(V) eluted at the same retention time and completely separated from organoarsenic species by an isocratic elution program on a reversed phase column. Therefore, neither ambiguous oxidation of arsenite to arsenate nor the integration of two peaks were necessary to determine directly the target analyte inorganic arsenic. Rapid injection allowed measuring 3 replicates within 6min and this combined with a quantitative extraction of all arsenic species from rice flour by a 15min HNO 3 -H 2 O 2 extraction makes this the fastest laboratory based method for inorganic arsenic in rice flour. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Measurement of M. luteus endonuclease-sensitive lesions by alkaline elution

    Energy Technology Data Exchange (ETDEWEB)

    Fornace, Jr, A J [National Cancer Inst., Bethesda, MD (USA). Lab. for Experimental Pathology

    1982-01-01

    The UV-endonuclease approach to detect DNA damage has been combined with the alkaline elution technique with a resultant marked increase in sensitivity compared to the conventional method using alkaline sedimentation. DNA from UV-irradiated cells was digested on an inert filter with an extract from Micrococcus luteus and then analyzed by alkaline elution. Endonuclease-sensitive sites (endo-sites) were measured after doses of 0.08-0.7 Jm/sup -2/ of UV-radiation. An estimate of endo-site production with UV radiation, 0.27 endo-sites/10/sup 8/ daltons of DNA/0.1 Jm/sup -2/, was similar to that usually seen at higher doses by others. With repair incubation, approx. 50% of the endo-sites were removed in 4 h by normal human fibroblasts after 0.2 or 0.4 Jm/sup -2/, no appreciable repair was seen in xeroderma pigmentosum fibroblasts from complementation group A after 24 h of repair incubation. No photoreaction of UV damage due to 0.4 Jm/sup -2/ was detected in normal human fibroblasts.

  2. Measurement of M. luteus endonuclease-sensitive lesions by alkaline elution

    International Nuclear Information System (INIS)

    Fornace, A.J. Jr.

    1982-01-01

    The UV-endonuclease approach to detect DNA damage has been combined with the alkaline elution technique with a resultant marked increase in sensitivity compared to the conventional method using alkaline sedimentation. DNA from UV-irradiated cells was digested on an inert filter with an extract from Micrococcus luteus and then analyzed by alkaline elution. Endonuclease-sensitive sites (endo-sites) were measured after doses of 0.08-0.7 Jm -2 of UV-radiation. An estimate of endo-site production with UV radiation, 0.27 endo-sites/10 8 daltons of DNA/0.1 Jm -2 , was similar to that usually seen at higher doses by others. With repair incubation, approx. 50% of the endo-sites were removed in 4 h by normal human fibroblasts after 0.2 or 0.4 Jm -2 , no appreciable repair was seen in xeroderma pigmentosum fibroblasts from complementation group A after 24 h of repair incubation. No photoreaction of UV damage due to 0.4 Jm -2 was detected in normal human fibroblasts. (orig./AJ)

  3. Clinical outcomes with drug-eluting and bare-metal stents in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego

    2013-01-01

    The authors investigated the relative safety and efficacy of different drug-eluting stents (DES) and bare metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) using a network meta-analysis.......The authors investigated the relative safety and efficacy of different drug-eluting stents (DES) and bare metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) using a network meta-analysis....

  4. Randomized clinical comparison of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent with the sirolimus-eluting Orsiro stent in patients treated with percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jakobsen, Lars; Christiansen, Evald H; Maeng, Michael

    2018-01-01

    Background: The Combo stent (OrbusNeich, Hoevelaken, the Netherlands) combining an abluminal, bioabsorbable polymer eluting sirolimus with a luminal CD34+ antibody to capture endothelial progenitor cells has been developed to further improve safety and efficacy of coronary interventions. We have...... designed a large-scale registry-based randomized clinical trial to compare the Combo stent to the Orsiro stent (Biotronik, Bülach, Switzerland) in patients undergoing percutaneous coronary intervention. Methods: The SORT OUT X study will randomly assign 3,140 patients to treatment with Combo or Orsiro...... stents at 3 sites in Western Denmark. Patients are eligible if they are ≥18 years old, have chronic stable coronary artery disease or acute coronary syndromes, and have ≥1 coronary lesion with >50% diameter stenosis requiring treatment with a drug-eluting stent. The primary end point target lesion...

  5. In-stent neoatherosclerosis and tissue characteristics of restenotic lesions following implantation of second generation drug-eluting stents in unrestricted coronary lesions: Optical frequency domain imaging study.

    Science.gov (United States)

    Sabbah, Mahmoud; Kadota, Kazushige; El-Eraky, Azza; Kamal, Hanan M; Abdellah, Ahmed-Tageldien; El Hawary, Ahmed

    2017-06-01

    Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appearance of the restenotic tissue. Utilizing Optical frequency domain imaging, two independent reviewers, retrospectively compared the prevalence of neoatherosclerosis (NA), and the morphological differences, and tissue characteristics of 50 G2-DESs in-stent restenosis (ISR) lesions (35 everolimus-eluting stent [22 cobalt-chromium (CoCr), 13 platinum-chromium (PtCr)], and 15 biolimus-eluting stent [BES]) implanted liberally in unrestricted coronary lesions. More than half of the stents were implanted in type C lesions, while 40% of the stents were implanted primarily in lesions with recanalized chronic total occlusion. NA, defined as a neointima formation with the presence of lipids or calcification, was observed in fewer than half (24/50) of all ISR lesions with no significant in-between group differences (41%, 69%, and 40% in CoCr, PtCr, and BES respectively, P = 0.22), nor were there any significant differences in the morphological appearance or tissue characteristics between all G2-DESs subtypes. Acknowledging some limitations, our results may suggest that the prevalence of NA and the morphological appearance of restenotic lesions might not differ when G2-DESs are implanted in unrestricted, rather complex, coronary lesions. © 2017, Wiley Periodicals, Inc.

  6. Type D personality predicts chronic anxiety following percutaneous coronary intervention in the drug-eluting stent era

    DEFF Research Database (Denmark)

    Spindler, Helle; Pedersen, Susanne S.; Serruys, Patrick W.

    2007-01-01

      Background: Anxiety is an often overlooked risk factor in coronary artery disease (CAD). Hence, little is known about predictors of unremitting chronic anxiety in CAD patients. This study examined whether the distressed personality (Type D) predicts chronic anxiety post percutaneous coronary...... months post-PCI. Results: Of 167 patients anxious at 6 months, 108 (65%) were still anxious 12 months post-PCI. Significant univariable predictors of chronic anxiety were Type D personality (OR:3.17: 95% CI:1.64-6.14) and sirolimus-eluting stents (OR:0.51; 95% CI:0.27-0.98), with sirolimus-eluting stents...... showing a protective effect. In multivariable analyses, Type D personality (OR:3.31; 95% CI:1.59-6.87) and sirolimus-eluting stents (OR:0.44; 95% CI:0.21-0.92) remained significant independent predictors of chronic anxiety adjusting for depressive symptoms at 6 months, and demographic and clinical risk...

  7. Speciation analysis of mercury in sediments, zoobenthos and river water samples by high-performance liquid chromatography hyphenated to atomic fluorescence spectrometry following preconcentration by solid phase extraction

    International Nuclear Information System (INIS)

    Margetinova, Jana; Houserova-Pelcova, Pavlina; Kuban, Vlastimil

    2008-01-01

    A high-pressure microwave digestion was applied for microwave-assisted extraction (MAE) of mercury species from sediments and zoobenthos samples. A mixture containing 3 mol L -1 HCl, 50% aqueous methanol and 0.2 mol L -1 citric acid (for masking co-extracted Fe 3+ ) was selected as the most suitable extraction agent. The efficiency of proposed extraction method was better than 95% with R.S.D. below 6%. A preconcentration method utilizing a 'homemade' C18 solid phase extraction (SPE) microcolumns was developed to enhance sensitivity of the mercury species determination using on-column complex formation of mercury-2-mercaptophenol complexes. Methanol was chosen for counter-current elution of the retained mercury complexes achieving a preconcentration factor as much as 1000. The preconcentration method was applied for the speciation analysis of mercury in river water samples. The high-performance liquid chromatography-cold vapour atomic fluorescence spectrometric (HPLC/CV-AFS) method was used for the speciation analysis of mercury. The complete separation of four mercury species was achieved by an isocratic elution of aqueous methanol (65%/35%) on a Zorbax SB-C18 column (4.6 mm x 150 mm, 5 μm) using the same complexation reagent (2-mercaptophenol). The limits of detection were 4.3 μg L -1 for methylmercury (MeHg + ), 1.4 μg L -1 for ethylmercury (EtHg + ), 0.8 μg L -1 for inorganic mercury (Hg 2+ ), 0.8 μg L -1 for phenylmercury (PhHg + )

  8. Cation exchange assisted binding-elution strategy for enzymatic synthesis of human milk oligosaccharides (HMOs).

    Science.gov (United States)

    Zhu, Hailiang; Wu, Zhigang; Gadi, Madhusudhan Reddy; Wang, Shuaishuai; Guo, Yuxi; Edmunds, Garrett; Guan, Wanyi; Fang, Junqiang

    2017-09-15

    A cation exchange assisted binding-elution (BE) strategy for enzymatic synthesis of human milk oligosaccharides (HMOs) was developed. An amino linker was used to provide the cation ion under acidic condition which can be readily bound to cation exchange resin and then eluted off by saturated ammonium bicarbonate. Ammonium bicarbonate in the collections was easily removed by vacuum evaporation. This strategy circumvented the incompatible issue between glycosyltransferases and solid support or large polymers, and no purification was needed for intermediate products. With current approach, polyLacNAc backbones of HMOs and fucosylated HMOs were synthesized smoothly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. study on 113 Sn-113m In generator of the chromatographic column elution mode

    International Nuclear Information System (INIS)

    Abdel-Halim, A.A.

    2002-01-01

    this work has been carried out to study the optimum conditions required for local preparation of 113 Sn- 113m In radioisotope generator based on 12- molybdocerate- 113 Sn column matrix. this work was directed to: 1- investigate the optimum conditions of the tin target irradiation and dissolution processes. 2- study the different preparative conditions which affect the loading of 113 Sn radionuclide onto 12- molybdocerate (IV) columns and the elution of the generated 113m In radionuclide. 3- study the effect of generator life- time on the elution performance and quality control of the generated 113m In radionuclide over a period of 190 days

  10. In Vivo and In Vitro Elution of Analgesics from Multilayered Poly(D,L-lactide-co-glycolide Nanofibers Incorporated Ureteral Stents

    Directory of Open Access Journals (Sweden)

    Yi-Chia Lin

    2018-01-01

    Full Text Available We develop novel analgesic-eluting nanofiber-incorporated ureteral stents that offer sustained release of lidocaine and ketorolac for local drug delivery. Lidocaine and poly(D,L-lactide-co-glycolide (PLGA were dissolved in hexafluoroisopropanol and were electrospun into nonwoven nanofibers onto the surface of ureteral stents. This was followed by electrospinning of another layer of PLGA nanofibers containing ketorolac. Electrospun drug-loaded nanofibers were then characterized using scanning electron microscopy, Fourier transform infrared spectroscopy, and water contact angle analysis. In addition, the elution behavior characteristics of the analgesics, both in vivo and in vitro, from the nanofiber-incorporated stents were evaluated. Experimental results indicate that the analgesic-eluting ureteral stents could liberate high strengths of analgesics in vitro and in vivo for at least 50 and 30 days, respectively. The analgesic-eluting nanofiber-incorporated ureteral stents are potentially applicable for alleviating the discomfort associated with stent implant.

  11. Drug-Eluting Balloons in the Treatment of Coronary De Novo Lesions

    DEFF Research Database (Denmark)

    Richelsen, Rasmus Kapalu Broge; Overvad, Thure Filskov; Jensen, Svend Eggert

    2016-01-01

    Drug-eluting balloons (DEBs) have emerged as a new application in percutaneous coronary intervention. DEBs have proven successful in the treatment of in-stent restenosis, but their role in de novo lesions is less clear. This paper provides a review of the current studies where DEBs have been used...

  12. Determination of inorganic ions in natural water by ion chromatography

    International Nuclear Information System (INIS)

    Nazaratul Ashifa Abdullah Salim; Mohd Suhaimi Hamzah; Eewiat Edin Put; Abdul Khalik Wood; Shamsiah Abdul Rahman; Md Suhaimi Elia

    2010-01-01

    Ion chromatography (IC) is a well established methodology for analysis of ionic species. The concentration of ionic species was determined using suppressed IC with conductivity detection. Anion species were determined in a single 15-min run with Na 2 CO 3 and NaHCO 3 eluent. Cation species were analysed by direct injection of 1 ml and isocratic elution with a methanesulfonic acid (MSA) eluent. Natural water were collected from various sources such as rainwater, lake, river and groundwater. Analysis performance of IC system was validated by evaluating the linear regression of calibration curve, recovery of spike sample and quality control sample. (author)

  13. Optimization of methodology to analyze ascorbic and dehydroascorbic acid in vegetables

    Directory of Open Access Journals (Sweden)

    Flávia Milagres Campos

    2009-01-01

    Full Text Available In this study, different solutions to extract vitamin C were tested. High-performance liquid chromatography was chosen and the conditions were based on isocratic elution in reverse phase column. Dehydroascorbic acid was determined indirectly after its reduction using dithiothreitol. The use of metaphosphoric acid to stabilize the vitamin C was shown to be required and it was necessary to neutralize the pH of the extract to apply dithiothreitol. The average recovery was 90% in collard and tomato samples. The presence of oil did not interfere in extraction and the methodology can be used to analyze stir fried vegetables.

  14. Outcome of everolimus eluting bioabsorbable vascular scaffold (BVS) compared to non BVS drug eluting stent in the management of ST-segment elevation myocardial infarction (STEMI) — A comparative study

    International Nuclear Information System (INIS)

    Chakraborty, Rabin; Patra, Soumya; Banerjee, Suvro; Pande, Arindam; Khan, Aftab; Mandol, Prakash Chandra; Ghosh, Debashish; De, Swapan Kumar; Das, Sankha Subhro; Nag, Raja

    2016-01-01

    Background: The safety and efficacy of everolimus eluting bioabsorbable vascular scaffold (BVS) in the management of “ST” segment elevation myocardial infarction (STEMI) are yet to be established. Aims: To evaluate immediate and short term safety and efficacy of the everolimus-eluting ABSORB BVS compared with non BVS drug eluting stent (DES) in patients with STEMI. Methods: From December 2013 to December 2014, 220 patients with STEMI were included in this study. Among them, 35 patients treated with BVS were compared with a control group composed of 180 patients who underwent non BVS DES implantation in the same time period. The incidence of major adverse cardiac events (MACE: stent thrombosis: death, non-fatal myocardial infarction, or target vessel/lesion revascularization) before discharge and up to six months was evaluated. Results: 1 vessel disease was more frequent whereas, 2 and 3 vessel disease was less frequent in BVS group. Procedural characteristics were also similar between groups, except for the use of post dilation (p = 0.04). Procedural success, in-hospital, and up to six-month MACE rates were similar between both groups. Definite or probable stent thrombosis did not occur (according to the ARC criteria) in BVS patients, though two patients during the index admission and another two patients in the first month after DES implantation had stent thrombosis. Conclusion: The use of the ABSORB BVS for STEMI is feasible and associated with good procedural safety, and angiographic success rate.

  15. Outcome of everolimus eluting bioabsorbable vascular scaffold (BVS) compared to non BVS drug eluting stent in the management of ST-segment elevation myocardial infarction (STEMI) — A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Rabin; Patra, Soumya, E-mail: dr_soumyapatra@rediffmail.com; Banerjee, Suvro; Pande, Arindam; Khan, Aftab; Mandol, Prakash Chandra; Ghosh, Debashish; De, Swapan Kumar; Das, Sankha Subhro; Nag, Raja

    2016-04-15

    Background: The safety and efficacy of everolimus eluting bioabsorbable vascular scaffold (BVS) in the management of “ST” segment elevation myocardial infarction (STEMI) are yet to be established. Aims: To evaluate immediate and short term safety and efficacy of the everolimus-eluting ABSORB BVS compared with non BVS drug eluting stent (DES) in patients with STEMI. Methods: From December 2013 to December 2014, 220 patients with STEMI were included in this study. Among them, 35 patients treated with BVS were compared with a control group composed of 180 patients who underwent non BVS DES implantation in the same time period. The incidence of major adverse cardiac events (MACE: stent thrombosis: death, non-fatal myocardial infarction, or target vessel/lesion revascularization) before discharge and up to six months was evaluated. Results: 1 vessel disease was more frequent whereas, 2 and 3 vessel disease was less frequent in BVS group. Procedural characteristics were also similar between groups, except for the use of post dilation (p = 0.04). Procedural success, in-hospital, and up to six-month MACE rates were similar between both groups. Definite or probable stent thrombosis did not occur (according to the ARC criteria) in BVS patients, though two patients during the index admission and another two patients in the first month after DES implantation had stent thrombosis. Conclusion: The use of the ABSORB BVS for STEMI is feasible and associated with good procedural safety, and angiographic success rate.

  16. Elution of Uranium and Transition Metals from Amidoxime-Based Polymer Adsorbents for Sequestering Uranium from Seawater

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Horng-Bin; Kuo, Li-Jung; Wai, Chien M.; Miyamoto, Naomi; Joshi, Ruma; Wood, Jordana R.; Strivens, Jonathan E.; Janke, Christopher J.; Oyola, Yatsandra; Das, Sadananda; Mayes, Richard T.; Gill, Gary A.

    2015-11-30

    High-surface-area amidoxime and carboxylic acid grafted polymer adsorbents developed at Oak Ridge National Laboratory were tested for sequestering uranium in a flowing seawater flume system at the PNNL-Marine Sciences Laboratory. FTIR spectra indicate that a KOH conditioning process is necessary to remove the proton from the carboxylic acid and make the sorbent effective for sequestering uranium from seawater. The alkaline conditioning process also converts the amidoxime groups to carboxylate groups in the adsorbent. Both Na2CO3-H2O2 and hydrochloric acid elution methods can remove ~95% of the uranium sequestered by the adsorbent after 42 days of exposure in real seawater. The Na2CO3-H2O2 elution method is more selective for uranium than conventional acid elution. Iron and vanadium are the two major transition metals competing with uranium for adsorption to the amidoxime-based adsorbents in real seawater.

  17. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials

    DEFF Research Database (Denmark)

    Tanimoto, Shuzou; Serruys, Patrick W; Thuesen, Leif

    2007-01-01

    OBJECTIVES: This study sought to evaluate and compare in vivo acute stent recoil of a novel bioabsorbable stent and a metallic stent. BACKGROUND: The bioabsorbable everolimus-eluting coronary stent (BVS) is composed of a poly-L-lactic acid backbone, coated with a bioabsorbable polymer containing...... the antiproliferative drug, everolimus, and expected to be totally metabolized and absorbed in the human body. Because the BVS is made from polymer, it may have more acute recoil than metallic stents in vivo. METHODS: A total of 54 patients, who underwent elective stent implantation for single de novo native coronary...... artery lesions, were enrolled: 27 patients treated with the BVS and 27 patients treated with the everolimus-eluting cobalt chromium stent (EES). Acute absolute recoil, assessed by quantitative coronary angiography, was defined as the difference between mean diameter of the last inflated balloon...

  18. Comparison of the Absorbable Polymer Sirolimus-Eluting Stent (MiStent) to the Durable Polymer Everolimus-Eluting Stent (Xience) (from the DESSOLVE I/II and ISAR-TEST-4 Studies).

    Science.gov (United States)

    Lansky, Alexandra J; Kastrati, Adnan; Edelman, Elazer R; Parise, Helen; Ng, Vivian G; Ormiston, John; Wijns, William; Byrne, Robert A

    2016-02-15

    We compared the outcomes of a novel, thin-strut, cobalt-chromium, absorbable, polymer sirolimus-eluting stent (APSES; MiStent) to the durable polymer cobalt-chromium everolimus-eluting stent (EES; Xience). A propensity-matched analysis was performed comparing data from the DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesions in the Native Coronary Arteries (DESSOLVE) I and II studies, evaluating the APSES to the EES arm of the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents-4 study. Target lesion failure (TLF) and its components were evaluated at 12 months and annually to 3 years; 805 patients (APSES = 153; EES = 652) were included with propensity matching in 204 patients (APSES = 102; EES = 102). APSES compared with EES had lower TLF at 1 year (3.0% vs 8.0%, p = 0.12) driven by a difference in target lesion revascularization (TLR; 1% vs 6%, p = 0.05), with no difference in target vessel myocardial infarction (p = 0.56) or stent thrombosis (p = 0.31). At 3 years, TLF (5.0% vs 12.5%, p = 0.07) and TLR (2.0% vs 8.4%, p = 0.04) remained lower with APSES. By landmark analysis, there was no significant difference in TLF between 1 and 3 years (p = 0.36). In conclusion, in a propensity-matched analysis, the APSES demonstrated reduced clinically indicated TLR rates at 1 and 3 years compared with the durable polymer EES, with minimal accrual of events between 1 and 3 years. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. AN ALTERNATIVE ELUENT TO BEEF EXTRACT FOR ELUTING POLIOVIRUS FROM ELECTROPOSITIVE FILTERS

    Science.gov (United States)

    Traditional methods for enteric virus removal from waters involve filtering the water through a positively charged filter followed by elution with beef extract, second step concentration by flocculation, and assay in cell culture. Two of the problems associated with this method ...

  20. Nine-month Angiographic and Two-year Clinical Follow-up of Novel Biodegradable-polymer Arsenic Trioxide-eluting Stent Versus Durable-polymer Sirolimus-eluting Stent For Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Li Shen

    2015-01-01

    Full Text Available Background: Despite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs have increased the risk of late stent thrombosis due to delayed endothelialization. Arsenic trioxide, a natural substance that could inhibit cell proliferation and induce cell apoptosis, seems to be a promising surrogate of sirolimus to improve DES performance. This randomized controlled trial was to evaluate the efficacy and safety of a novel arsenic trioxide-eluting stent (AES, compared with traditional sirolimus-eluting stent (SES. Methods: Patients with symptoms of angina pectoris were enrolled and randomized to AES or SES group. The primary endpoint was target vessel failure (TVF, and the second endpoint includes rates of all-cause death, cardiac death or myocardial infarction, target lesion revascularization (TLR by telephone visit and late luminal loss (LLL at 9-month by angiographic follow-up. Results: From July 2007 to 2009, 212 patients were enrolled and randomized 1:1 to receive either AES or SES. At 2 years of follow-up, TVF rate was similar between AES and SES group (6.67% vs. 5.83%, P = 0.980. Frequency of all-cause death was significantly lower in AES group (0 vs. 4.85%, P = 0.028. There was no significant difference between AES and SES in frequency of TLR and in-stent restenosis, but greater in-stent LLL was observed for AES group (0.29 ± 0.52 mm vs. 0.10 ± 0.25 mm, P = 0.008. Conclusions: After 2 years of follow-up, AES demonstrated comparable efficacy and safety to SES for the treatment of de novo coronary artery lesions.

  1. Unfolding and aggregation of a glycosylated monoclonal antibody on a cation exchange column. Part I. Chromatographic elution and batch adsorption behavior.

    Science.gov (United States)

    Guo, Jing; Zhang, Shaojie; Carta, Giorgio

    2014-08-22

    A glycosylated IgG2 monoclonal antibody exhibits a two-peak elution behavior when loaded on a strong cation exchange column and eluted with either a linear salt gradient or two salt steps at increasing salt concentrations. The two-peak behavior is more pronounced for conditions where the initial antibody binding is stronger, i.e. at lower pH and buffer concentration, where the hold time prior to elution is longer, where the protein mass load is lower, and where the load flow rate is higher. The effect is also dependent on the resin type, being prominent for the polymer-functionalized resin Fractogel EMD SO₃(-) and virtually absent for a macroporous resin with similar backbone but no grafted polymers. Size exclusion chromatography and dynamic light scattering show that the early eluting peak consists exclusively of the native monomeric species while the late eluting peak is a mixture of monomeric and aggregated species. Batch adsorption/desorption experiments show that the bound protein can be desorbed in two steps, with a fraction desorbed in 0.33 M NaCl, corresponding to native monomer, and a second fraction desorbed in 1M NaCl. The latter fraction decreases with protein mass load and becomes almost negligible when the resin is initially completely saturated with protein. Confocal laser scanning microscopy showed that the two-peak elution/desorption behavior is related to the unique kinetics of protein binding in the Fractogel resin. Following partial loading of the resin, the bound protein migrates toward the center of the particles during a hold step and is redistributed across the particle volume attaining low local bound protein concentrations. For these conditions the protein is apparently destabilized forming a strongly-bound unfolded intermediate that, in turn, generates aggregates upon elution in high salt. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Paclitaxel-eluting stents versus everolimus-eluting coronary stents in a diabetic population: two-year follow-up of the TUXEDO-India trial.

    Science.gov (United States)

    Kaul, Upendra; Bhagwat, Ajit; Pinto, Brian; Goel, Praveen K; Jagtap, Prashant; Sathe, Shireesh; Wander, Gurpreet S; Arambam, Priyadarshini; Bangalore, Sripal

    2017-11-20

    The aim of this study was to report whether the superiority of the everolimus-eluting stent (EES) vs. the paclitaxel-eluting stent (PES) at one-year follow-up in the Taxus Element versus Xience Prime in a Diabetic Population (TUXEDO)-India trial was sustained at longer-term follow-up. One thousand eight hundred and thirty (1,830) patients with diabetes mellitus and coronary artery disease were randomised to EES vs. PES. Follow-up data up to two years were available in 1,701 (92.9%) patients. The primary endpoint was target vessel failure (TVF), defined as the composite of cardiac death, target vessel myocardial infarction (TV-MI), or ischaemia-driven target vessel revascularisation (TVR). Treatment with EES had a lower two-year rate of TVF (4.3% vs. 6.6%, p=0.03). Of the secondary endpoints, EES significantly reduced any MI (1.6% vs. 3.5%, p=0.01), TV-MI (0.7% vs. 3.1%, p=0.0001), ST (0.4% vs. 2.2%, p=0.001), cardiac death or target vessel MI (2.9% vs. 4.8%, p=0.04) and TLR (1.9% vs. 3.7%, p=0.02), compared with PES. Between one year and two years, no significant differences in the clinical outcomes were observed (pinteraction >0.05). In this adequately powered trial, the benefits of EES vs. PES in a diabetic population seen at one year were maintained at two years.

  3. Application of resistivity measurements to the control of protein elutions using cellulose ion-exchangers; Application de la mesure de resistivite au controle d'une elution de proteines a partir de celluloses echangeuses d'ions

    Energy Technology Data Exchange (ETDEWEB)

    Duplaa, A M; Brandolin, G [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    The eluate obtained by chromatography of a mixture of proteins on columns of cellulose ion-exchangers (DEAE-cellulose and CM-cellulose) sometimes have very low proteins concentrations. The resistivity measurement gives more information than the UV control which is often inadequate. The modifications undergone by elution buffers are recorded and the best conditions for the extraction of an enzymatic protein are determined. The tests are performed without proteins on the columns; they consist in a double control of resistivity and ph of elution buffers after they pass on the exchangers columns. (author) [French] Apres chromatographie d'un melange de proteine; sur colonnes d'echangeurs d'ions tels que DEAE-cellulose et CM-cellulose, les eluats obtenus ont quelquefois des concentrations en proteines tres faibles. Au controle en UV souvent insuffisant, on a ajoute la mesure de resistivite apportant des donnees complementaires. Des essais, realises en l'absence de proteines et consistant a effectuer un double controle de resistivite et de pH des tampons d'elution apres leur passage sur colonnes d'echangeurs, ont permis d'enregistrer les modifications subies par ces tampons et de determiner leurs meilleures conditions d'utilisation pour l'extraction d'une proteine enzymatique. (auteur)

  4. Retention modeling under organic modifier gradient conditions in ion-pair reversed-phase chromatography. Application to the separation of a set of underivatized amino acids.

    Science.gov (United States)

    Pappa-Louisi, A; Agrafiotou, P; Papachristos, K

    2010-07-01

    The combined effect of the ion-pairing reagent concentration, C(ipr), and organic modifier content, phi, on the retention under phi-gradient conditions at different constant C(ipr) was treated in this study by using two approaches. In the first approach, the prediction of the retention time of a sample solute is based on a direct fitting procedure of a proper retention model to 3-D phi-gradient retention data obtained under the same phi-linear variation but with different slope and time duration of the initial isocratic part and in the presence of various constant C(ipr) values in the eluent. The second approach is based on a retention model describing the combined effect of C(ipr) and phi on the retention of solutes in isocratic mode and consequently analyzes isocratic data obtained in mobile phases containing different C(ipr) values. The effectiveness of the above approaches was tested in the retention prediction of a mixture of 16 underivatized amino acids using mobile phases containing acetonitrile as organic modifier and sodium dodecyl sulfate as ion-pairing reagent. From these approaches, only the first one gives satisfactory predictions and can be successfully used in optimization of ion-pair chromatographic separations under gradient conditions. The failure of the second approach to predict the retention of solutes in the gradient elution mode in the presence of different C(ipr) values was attributed to slow changes in the distribution equilibrium of ion-pairing reagents caused by phi-variation.

  5. The application of PLC automatic control system for resin transfer in pulsed elution

    International Nuclear Information System (INIS)

    Long Maoxiong

    2001-01-01

    An application of Programmable Logic Controller (PLC) in automatic control system for resin transfer in pulsed elution column is described. The design principle as well as hardware and software are also described in detail

  6. A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study

    Directory of Open Access Journals (Sweden)

    Teeuwen Koen

    2012-12-01

    Full Text Available Abstract Background Percutaneous recanalization of total coronary occlusion (TCO was historically hampered by high rates of restenosis and reocclusions. The PRISON II trial demonstrated a significant restenosis reduction in patients treated with sirolimus-eluting stents compared with bare metal stents for TCO. Similar reductions in restenosis were observed with the second-generation zotarolimus-eluting stent and everolimus-eluting stent. Despite favorable anti-restenotic efficacy, safety concerns evolved after identifying an increased rate of very late stent thrombosis (VLST with drug-eluting stents (DES for the treatment of TCO. Late malapposition caused by hypersensitivity reactions and chronic inflammation was suggested as a probable cause of these VLST. New DES with bioresorbable polymer coatings were developed to address these safety concerns. No randomized trials have evaluated the efficacy and safety of the new-generation DES with bioresorbable polymers in patients treated for TCO. Methods/Design The prospective, randomized, single-blinded, multicenter, non-inferiority PRISON IV trial was designed to evaluate the safety, efficacy, and angiographic outcome of hybrid sirolimus-eluting stents with bioresorbable polymers (Orsiro; Biotronik, Berlin, Germany compared with everolimus-eluting stents with durable polymers (Xience Prime/Xpedition; Abbott Vascular, Santa Clara, CA, USA in patients with successfully recanalized TCOs. In total, 330 patients have been randomly allocated to each treatment arm. Patients are eligible with estimated duration of TCO ≥4 weeks with evidence of ischemia in the supply area of the TCO. The primary endpoint is in-segment late luminal loss at 9-month follow-up angiography. Secondary angiographic endpoints include in-stent late luminal loss, minimal luminal diameter, percentage of diameter stenosis, in-stent and in-segment binary restenosis and reocclusions at 9-month follow-up. Additionally, optical coherence

  7. Elution of Clindamycin and Enrofloxacin From Calcium Sulfate Hemihydrate Beads In Vitro.

    Science.gov (United States)

    Phillips, Heidi; Boothe, Dawn M; Bennett, R Avery

    2015-11-01

    To compare the in vitro elution characteristics of clindamycin and enrofloxacin from calcium sulfate hemihydrate beads containing a single antibiotic, both antibiotics, and each antibiotic incubated in the same eluent well. Experimental in vitro study. Calcium sulfate hemihydrate beads were formed by mixing with clindamycin and/or enrofloxacin to create 4 study groups: (1) 160 mg clindamycin/10 beads; (2) 160 mg enrofloxacin/10 beads; (3) 160 mg clindamycin + 160 mg enrofloxacin/10 beads; and (4) 160 mg clindamycin/5 beads and 160 mg enrofloxacin/5 beads. Chains of beads were formed in triplicate and placed in 5 mL phosphate buffered saline (PBS; pH 7.4 and room temperature) with constant agitation. Antibiotic-conditioned PBS was sampled at 14 time points from 1 hour to 30 days. Clindamycin and enrofloxacin concentrations in PBS were determined using high-performance liquid chromatography. Eluent concentrations from clindamycin-impregnated beads failed to remain sufficiently above minimum inhibitory concentration (MIC) for common infecting bacteria over the study period. Enrofloxacin eluent concentrations remained sufficiently above MIC for common wound pathogens of dogs and cats and demonstrated an atypical biphasic release pattern. No significant differences in elution occurred as a result of copolymerization of the antibiotics into a single bead or from individual beads co-eluting in the same eluent well. Clindamycin-impregnated beads cannot be recommended for treatment of infection at the studied doses; however, use of enrofloxacin-impregnated beads may be justified when susceptible bacteria are cultured. © Copyright 2015 by The American College of Veterinary Surgeons.

  8. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  9. Elution of Uranium and Calculation of Plate Number on the Column of Silica-TBP

    International Nuclear Information System (INIS)

    Endang Susiantini; Indra Suryawan

    2007-01-01

    Separation process of 99 Mo resulted of irradiated uranyl nitrate with an accelerator as the neutron source by the chromatographic extraction using column containing kiesel gel-TBP will be developed. Kiesel gel (silica) was used as an inert subpart, TBP as a phase stationary and simulated used natural uranyl nitrate of 200-300 g/l with the acidity of 2 N as the mobile phase. The inert support was made by means of kiesel-gel (silica) hydrophobization to change hydrophilic silica to hydrophobic silica, so that it could be impregnated by TBP. Uranium which has been attached to TBP would be eluted by dilute acid at acidity of 0.05; 0.1; 0.2 N HNO 3 ; Warm DW and cool DW. By using 0.1 N HNO 3 eluent and warm DW the uranium attached to silica-TBP could be eluted perfectly and more quickly than the three others eluent. Uranium concentration which were absorbed and eluted were analysed titrimetrically by using titan method and it was used to calculate Plate Number (N). The value of N obtained for the column which the inert support of 8 cm in height, 1 cm in diameter, 10 drops per minute by using of 0.1 N HNO 3 eluent was 300.6. (author)

  10. A Simple and Effective Isocratic HPLC Method for Fast Identification and Quantification of Surfactin

    International Nuclear Information System (INIS)

    Muhammad Qadri Effendy Mubarak; Abdul Rahman Hassan; Aidil Abdul Hamid; Sahaid Khalil; Mohd Hafez Mohd Isa

    2015-01-01

    The aim of this study was to establish a simple, accurate and reproducible method for the identification and quantification of surfactin using high-performance liquid chromatography (HPLC). Previously reported method of identification and quantification of surfactin were time consuming and requires a large quantity of mobile phase. The new method was achieved by application of Chromolith® high performance RP-18 (100 x 4.6 mm, 5 μm) as the stationary phase and optimization of mobile phase ratio and flow rate. Mobile phase consisted of acetonitrile (ACN) and 3.8 mM trifluroacetic acid (TFA) solution of 80:20 ratio at flow rate of 2.2 mL/ min was obtained as the optimal conditions. Total elution time of the obtained surfactin peaks was four times quicker than various methods previously reported in the literature. The method described here allowed for fine separation of surfactin in standard sample (98 % purity) and surfactin in fermentation broth. (author)

  11. Hepatic Arterial Chemoembolization Using Drug-Eluting Beads in Gastrointestinal Neuroendocrine Tumor Metastatic to the Liver

    International Nuclear Information System (INIS)

    Gaur, Shantanu K.; Friese, Jeremy L.; Sadow, Cheryl A.; Ayyagari, Rajasekhara; Binkert, Christoph A.; Schenker, Matthew P.; Kulke, Matthew; Baum, Richard

    2011-01-01

    Purpose: This study was designed to evaluate short ( 3 months) follow-up in patients with metastatic neuroendocrine tumor to the liver who underwent hepatic arterial chemoembolization with drug-eluting beads at a single institution. Methods: Institutional review board approval was obtained for this retrospective review. All patients who were treated with 100–300 or 300–500 μm drug-eluting LC Beads (Biocompatibles, UK) preloaded with doxorubicin (range, 50–100 mg) for GI neuroendocrine tumor metastatic to the liver from June 2004 to June 2009 were included. CT and MRI were evaluated for progression using Response Evaluation Criteria In Solid Tumors (RECIST) or European Association for the Study of the Liver (EASL) criteria. Short-term ( 3 months) imaging response was determined and Kaplan–Meier survival curves were plotted. Results: Thirty-eight drug-eluting bead chemoembolization procedures were performed on 32 hepatic lobes, comprising 21 treatment cycles in 18 patients. All procedures were technically successful with two major complications (biliary injuries). At short-term follow-up (<3 months), 22 of 38 (58%) procedures and 10 of 21 (48%) treatment cycles produced an objective response (OR) with the remainder having stable disease (SD). At intermediate-term follow-up (mean, 445 days; range, 163–1247), 17 of 26 (65%) procedures and 8 of 14 (57%) treatment cycles produced an OR. Probability of progressing was approximately 52% at 1 year with a median time to progression of 419 days. Conclusions: Drug-eluting bead chemoembolization is a reasonable alternative to hepatic arterial embolization and chemoembolization for the treatment of metastatic neuroendocrine tumor to the liver.

  12. Study of the elution 99Mo-99mTc generators produced at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Lopes, Paula Regina Corain; Osso Junior, Joao Alberto

    2007-01-01

    Over the last years 99m Tc has become a very important asset in modern nuclear medicine, due to the emission of gamma ray of optimal energy (140 keV) and a suitable half-life (6.04 h). A further attribute of 99m Tc is its formation from the decay of 99 Mo and the availability from 99 Mo- 99m Tc generator systems. The most common and practical generator types consist of a chromatographic column packed with aluminium oxide, onto which the highly purified fission product 99 Mo (imported from Canada) is adsorbed in the form of molybdate. 99m Tc is further eluted with saline solution. The objective of this work is to study the performance and the elution profile of 99m Tc from high activity generators in order to decrease molybdenum and aluminium concentration. The experiments involved the use of paper filters and Sep Pak columns and also the changing in the time interval between elutions. 99 Mo breakthrough was measured using a dose calibrator and aluminium by UV-Vis spectrophotometry. The best results were achieved using a Sep Pak column containing neutral aluminium oxide. (author)

  13. Rapid detection of DNA-interstrand and DNA-protein cross-links in mammalian cells by gravity-flow alkaline elution

    International Nuclear Information System (INIS)

    Hincks, J.R.; Coulombe, R.A. Jr.

    1989-01-01

    Alkaline elution is a sensitive and commonly used technique to detect cellular DNA damage in the form of DNA strand breaks and DNA cross-links. Conventional alkaline elution procedures have extensive equipment requirements and are tedious to perform. Our laboratory recently presented a rapid, simplified, and sensitive modification of the alkaline elution technique to detect carcinogen-induced DNA strand breaks. In the present study, we have further modified this technique to enable the rapid characterization of chemically induced DNA-interstrand and DNA-protein associated cross-links in cultured epithelial cells. Cells were exposed to three known DNA cross-linking agents, nitrogen mustard (HN 2 ), mitomycin C (MMC), or ultraviolet irradiation (UV). One hour exposures of HN 2 at 0.25, 1.0, and 4.0 microM or of MMC at 20, 40, and 60 microM produced a dose-dependent induction of total DNA cross-links by these agents. Digestion with proteinase K revealed that HN 2 and MMC induced both DNA-protein cross-links and DNA-interstrand cross-links. Ultraviolet irradiation induced both DNA cross-links and DNA strand breaks, the latter of which were either protein and nonprotein associated. The results demonstrate that gravity-flow alkaline elution is a sensitive and accurate method to characterize the molecular events of DNA cross-linking. Using this procedure, elution of DNA from treated cells is completed in 1 hr, and only three fractions per sample are analyzed. This method may be useful as a rapid screening assay for genotoxicity and/or as an adjunct to other predictive assays for potential mutagenic or carcinogenic agents

  14. X-ray induced DNA double strand break production and repair in mammalian cells as measured by neutral filter elution

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, M O; Kohn, K W [National Institutes of Health, Bethesda, MD (USA)

    1979-10-01

    A neutral filter elution method was used for detecting DNA double strand breaks in mouse L1210 cells after X-ray. The assay detected the number of double strand breaks induced by as little as 1000 rad of X-ray. The rate of DNA elution through the filters under neutral conditions increased with X-ray dose. Certain conditions for deproteinization, pH, and filter type were shown to increase the assay's sensitivity. Hydrogen peroxide and Bleomycin also induced apparent DNA double strand breaks, although the ratios of double to single strand breaks varied from those produced by X-ray. The introduction of double strand cuts by HpA I restriction endonuclease in DNA lysed on filters resulted in a rapid rate of elution under neutral conditions, implying that the method can detect double strand breaks if they exist in the DNA. The eluted DNA banded with a double stranded DNA marker in cesium chloride. This evidence suggested that the assay detected DNA double strand breaks. L1210 cells were shown to rejoin most of the DNA double strand breaks induced by 5-10 krad of X-ray with a half-time of about 40 minutes. (author).

  15. Vascular Response of the Segments Adjacent to the Proximal and Distal Edges of the ABSORB Everolimus-Eluting Bioresorbable Vascular Scaffold

    DEFF Research Database (Denmark)

    Gogas, Bill D; Serruys, Patrick W; Diletti, Roberto

    2012-01-01

    This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS).......This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS)....

  16. Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Taniwaki, Masanori; Radu, Maria D; Zaugg, Serge

    2016-01-01

    BACKGROUND: The pathomechanisms underlying very late stent thrombosis (VLST) after implantation of drug-eluting stents (DES) are incompletely understood. Using optical coherence tomography, we investigated potential causes of this adverse event. METHODS AND RESULTS: Between August 2010 and Decemb...

  17. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    Science.gov (United States)

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  18. REUSABILITY OF BOND ELUT CERTIFY COLUMNS FOR THE EXTRACTION OF DRUGS FROM PLASMA

    NARCIS (Netherlands)

    CHEN, XH; FRANKE, JP; WIJSBEEK, J; DEZEEUW, RA

    1993-01-01

    The reusability of Bond Elut Certify columns for the extraction of toxicologically relevant drugs from plasma has been evaluated. Pentobarbital, hexobarbital, mepivacaine, trimipramine and clonazepam were selected as test drugs to represent various classes of drugs. The columns were regenerated

  19. Advantages and disadvantages of biodegradable platforms in drug eluting stents.

    Science.gov (United States)

    Rodriguez-Granillo, Agustina; Rubilar, Bibiana; Rodriguez-Granillo, Gaston; Rodriguez, Alfredo E

    2011-03-26

    Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to bare-metal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.

  20. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Holmvang, Lene; Kelbæk, Henning; Kaltoft, Anne Kjer

    2013-01-01

    This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention.......This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention....

  1. Determination of 99Mo contamination in 99mTc elute obtained from 99Mo/99mTc- generator

    International Nuclear Information System (INIS)

    Momennezhad, M.; Zakavi, S. R.; Sadeghi, R.

    2010-01-01

    99m Tc is a widely used radioisotope in nuclear medicine centers which is obtained by elution from Mo-99/Tc-99m generators. Usually the generators are either supplied by the Iran Atomic Energy Agency or by private companies from foreign countries. In this study we have measured 99 Mo contamination in 99m Tc elute from different generators in a period of one year. Materials and Methods: The radionuclide impurity of the 99m Tc elute were studied in two types of radionuclide generators (A: produced in Iran and B: Imported from other country). In-vitro measurements were performed using dose calibrator. Direct measurements were made, using a standard canister at the time of milking of the generators and also in Subsequent hours after milking. Results: The results showed a mean of 99 Mo impurity in generators A and B to be 0.00932±0.0043 and 0.0170±0.0127 respectively. Although the results showed that the 99 Mo contamination in 99 mTc elute was lesser than the maximum accepted activity limit of 0.015%, the difference in these two types may reflect different methods of productions of generator, as well as the quality control procedures. Conclusion: The mean of 99 Mo contamination in generators produced in Iran Atomic Energy Organization was lesser than generators imported from foreign origin.

  2. Synthesis of a mixed-model stationary phase derived from glutamine for HPLC separation of structurally different biologically active compounds: HILIC and reversed-phase applications.

    Science.gov (United States)

    Aral, Tarık; Aral, Hayriye; Ziyadanoğulları, Berrin; Ziyadanoğulları, Recep

    2015-01-01

    A novel mixed-mode stationary phase was synthesised starting from N-Boc-glutamine, aniline and spherical silica gel (4 µm, 60 Å). The prepared stationary phase was characterized by IR and elemental analysis. The new stationary phase bears an embedded amide group into phenyl ring, highly polar a terminal amide group and non-polar groups (phenyl and alkyl groups). At first, this new mixed-mode stationary phase was used for HILIC separation of four nucleotides and five nucleosides. The effects of different separation conditions, such as pH value, mobile phase and temperature, on the separation process were investigated. The optimum separation for nucleotides was achieved using HILIC isocratic elution with aqueous mobile phase and acetonitrile with 20°C column temperature. Under these conditions, the four nucleotides could be separated and detected at 265 nm within 14 min. Five nucleosides were separated under HILIC isocratic elution with aqueous mobile phase containing pH=3.25 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 265 nm within 14 min. Chromatographic parameters as retention factor, selectivity, theoretical plate number and peak asymmetry factor were calculated for the effect of temperature and water content in mobile phase on the separation process. The new column was also tested for nucleotides and nucleosides mixture and six analytes were separated in 10min. The chromatographic behaviours of these polar analytes on the new mixed-model stationary phase were compared with those of HILIC columns under similar conditions. Further, phytohormones and phenolic compounds were separated in order to see influence of the new stationary phase in reverse phase conditions. Eleven plant phytohormones were separated within 13 min using RP-HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 230 or 278 nm. The best separation

  3. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent

    DEFF Research Database (Denmark)

    Ishibashi, Yuki; Muramatsu, Takashi; Nakatani, Shimpei

    2015-01-01

    OBJECTIVES: This study sought to evaluate the mechanism of post-procedural cardiac biomarker (CB) rise following device implantation. BACKGROUND: A fully bioresorbable Absorb scaffold, compared with everolimus-eluting metallic stents (EES), might be associated with a higher incidence...

  4. Determinação simultânea dos ácidos orgânicos tartárico, málico, ascórbico e cítrico em polpas de acerola, açaí e caju e avaliação da estabilidade em sucos de caju Simulataneous determination of tartaric, malic, ascorbic and citric acids in acerola, açai and cashew pulps, and stability evaluation in cashew juices

    Directory of Open Access Journals (Sweden)

    Rodrigo Scherer

    2008-01-01

    Full Text Available The aim of the present study was determining the main organic acids in pulp and juices, as well as evaluating their stability, after opening the package, by liquid chromatography in a C18 column with isocratic elution and UV detection. In açaí pulp tartaric, malic and citric acids were found. Cashew samples presented all of the organic acids evaluated, besides high concentrations of ascorbic and malic acids. Acerola pulp had the highest ascorbic acid concentration. A small decrease in organic acid content during storage was observed. Malic and citric acids seem to be more stable than tartaric and ascorbic acids.

  5. Fast Gradient Elution Reversed-Phase HPLC with Diode-Array Detection as a High Throughput Screening Method for Drugs of Abuse

    Energy Technology Data Exchange (ETDEWEB)

    Peter W. Carr; K.M. Fuller; D.R. Stoll; L.D. Steinkraus; M.S. Pasha; Glenn G. Hardin

    2005-12-30

    A new approach has been developed by modifying a conventional gradient elution liquid chromatograph for the high throughput screening of biological samples to detect the presence of regulated intoxicants. The goal of this work was to improve the speed of a gradient elution screening method over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which are the basis for the identification. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between gradient runs, thereby reducing the total time for each analysis. The total analysis time for each gradient elution run is only 2.8 minutes, including 0.3 minutes for column reequilibration between analyses. Retention times standard calibration solutes are reproducible to better than 0.002 minutes in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. The discriminating power and mean list length were calculated for a library of 47 intoxicants and compared with previous work from other laboratories to evaluate fast gradient elution HPLC as a screening tool.

  6. Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction.

    Science.gov (United States)

    Pilgrim, Thomas; Piccolo, Raffaele; Heg, Dik; Roffi, Marco; Tüller, David; Vuilliomenet, André; Muller, Olivier; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Khattab, Ahmed A; Taniwaki, Masanori; Rigamonti, Fabio; Nietlispach, Fabian; Blöchlinger, Stefan; Wenaweser, Peter; Jüni, Peter; Windecker, Stephan

    2016-12-10

    Our aim was to compare the safety and efficacy of a novel, ultrathin strut, biodegradable polymer sirolimus-eluting stent (BP-SES) with a thin strut, durable polymer everolimus-eluting stent (DP-EES) in a pre-specified subgroup of patients with acute ST-segment elevation myocardial infarction (STEMI) enrolled in the BIOSCIENCE trial. The BIOSCIENCE trial is an investigator-initiated, single-blind, multicentre, randomised non-inferiority trial (NCT01443104). Randomisation was stratified according to the presence or absence of STEMI. The primary endpoint, target lesion failure (TLF), is a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation within 12 months. Between February 2012 and May 2013, 407 STEMI patients were randomly assigned to treatment with BP-SES or DP-EES. At one year, TLF occurred in seven (3.4%) patients treated with BP-SES and 17 (8.8%) patients treated with DP-EES (RR 0.38, 95% CI: 0.16-0.91, p=0.024). Rates of cardiac death were 1.5% in the BP-SES group and 4.7% in the DP-EES group (RR 0.31, 95% CI: 0.08-1.14, p=0.062); rates of target vessel myocardial infarction were 0.5% and 2.6% (RR 0.18, 95% CI: 0.02-1.57, p=0.082), respectively, and rates of clinically indicated target lesion revascularisation were 1.5% in the BP-SES group versus 2.1% in the DP-EES group (RR 0.69, 95% CI: 0.16-3.10, p=0.631). There was no difference in the risk of definite stent thrombosis. In this pre-specified subgroup analysis, BP-SES was associated with a lower rate of target lesion failure at one year compared to DP-EES in STEMI patients. These findings require confirmation in a dedicated STEMI trial.

  7. Improved two-year outcomes after drug-eluting versus bare-metal stent implantation in women and men with large coronary arteries

    DEFF Research Database (Denmark)

    Hansen, K W; Kaiser, C; Hvelplund, A

    2013-01-01

    To investigate the importance of vessel size on outcome differences by comparing the effects of drug-eluting stents (DES) versus bare-metal stents (BMS) in women and men with large coronary vessels.......To investigate the importance of vessel size on outcome differences by comparing the effects of drug-eluting stents (DES) versus bare-metal stents (BMS) in women and men with large coronary vessels....

  8. Arterial healing following primary PCI using the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) versus the durable polymer everolimus-eluting metallic stent (XIENCE) in patients with acute ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Onuma, Yoshinobu; Brugaletta, Salvatore

    2015-01-01

    Aims: The Absorb bioresorbable vascular scaffold (Absorb BVS) provides similar clinical outcomes compared with a durable polymer-based everolimus-eluting metallic stent (EES) in stable coronary artery disease patients. ST-elevation myocardial infarction (STEMI) lesions have been associated with d...

  9. Separation of light lanthanons by ion exchange with ammonium acetate. Pt. 2. The influence of the conditions of elution on separation efficiency

    International Nuclear Information System (INIS)

    Hubicka, H.; Hubicki, W.

    1980-01-01

    The influence of concentration, pH of ammonium acetate, reaction rate, temperature, the way of chromatogram development and composition of being separated mixture upon effective distribution of light lanthanons were studied. The elution for pH 6.8 - 7.0 gives the maximum of eluent concentrations. The decrease of pH and of the initial eluent concentration may give better distributions at longer time of elution. The elution by means of ammonium acetate without yttrium in the light lanthanons concentrate may give Nd 2 O 3 of purity 99,9%. The increase of temperature (70 - 80 0 C) and the addition of ammonium salts to eluent influence unprofitably the distribution. (author)

  10. A fully validated bioanalytical method using an UHPLC-MS/MS system for quantification of DNA and RNA oxidative stress biomarkers.

    Science.gov (United States)

    Cervinkova, Barbora; Krcmova, Lenka Kujovska; Sestakova, Veronika; Solichova, Dagmar; Solich, Petr

    2017-05-01

    A new, rapid and effective ultra-high-performance liquid chromatography method with mass spectrometry detection is described for the separation and quantification of 8-hydroxy-2-deoxyguanosine, 8-hydroxyguanosine and creatinine in human urine. The present study uses an isotope-labelled internal standard ([ 15 N] 5 -8-hydroxy-2-deoxyguanosine), a BIO core-shell stationary phase and an isocratic elution of methanol and water. Sample preparation of human urine was performed by solid-phase extraction (SPE) on Oasis HLB cartridges with methanol/water 50:50 (v/v) elution. Extraction recoveries ranged from 98.1% to 109.2%. Biological extracts showed high short-term stability. Several aspects of this procedure make it suitable for both clinical and research purposes: a short elution time of less than 3.2 min, an intra-day precision of 2.5-8.9%, an inter-day precision of 3.4-8.7% and low limits of quantification (27.7 nM for 8-hydroxyguanosine, 6.0 nM for 8-hydroxy-2-deoxyguanosine). Finally, simultaneous analysis of DNA and RNA oxidative stress biomarkers is a useful tool for monitoring disease progression in neurodegenerative disorders and cancer. Graphical abstract UHPLC-MS/MS analysis of DNA and RNA oxidative stress biomarkers.

  11. The Impact of Post-Procedural Asymmetry, Expansion, and Eccentricity of Bioresorbable Everolimus-Eluting Scaffold and Metallic Everolimus-Eluting Stent on Clinical Outcomes in the ABSORB II Trial.

    Science.gov (United States)

    Suwannasom, Pannipa; Sotomi, Yohei; Ishibashi, Yuki; Cavalcante, Rafael; Albuquerque, Felipe N; Macaya, Carlos; Ormiston, John A; Hill, Jonathan; Lang, Irene M; Egred, Mohaned; Fajadet, Jean; Lesiak, Maciej; Tijssen, Jan G; Wykrzykowska, Joanna J; de Winter, Robbert J; Chevalier, Bernard; Serruys, Patrick W; Onuma, Yoshinobu

    2016-06-27

    The study sought to investigate the relationship between post-procedural asymmetry, expansion, and eccentricity indices of metallic everolimus-eluting stent (EES) and bioresorbable vascular scaffold (BVS) and their respective impact on clinical events at 1-year follow-up. Mechanical properties of a fully BVS are inherently different from those of permanent metallic stent. The ABSORB II (A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions) trial compared the BVS and metallic EES in the treatment of a de novo coronary artery stenosis. Protocol-mandated intravascular ultrasound imaging was performed pre- and post-procedure in 470 patients (162 metallic EES and 308 BVS). Asymmetry index (AI) was calculated per lesion as: (1 - minimum scaffold/stent diameter/maximum scaffold/stent diameter). Expansion index and optimal scaffold/stent expansion followed the definition of the MUSIC (Multicenter Ultrasound Stenting in Coronaries) study. Eccentricity index (EI) was calculated as the ratio of minimum and maximum scaffold/stent diameter per cross section. The incidence of device-oriented composite endpoint (DoCE) was collected. Post-procedure, the metallic EES group was more symmetric and concentric than the BVS group. Only 8.0% of the BVS arm and 20.0% of the metallic EES arm achieved optimal scaffold/stent expansion (p 0.30 is an independent predictor of DoCE (hazard ratio: 3.43; 95% confidence interval: 1.08 to 10.92; p = 0.037). BVS implantation is more frequently associated with post-procedural asymmetric and eccentric morphology compared to metallic EES. Post-procedural devices asymmetry were independently associated with DoCE following percutaneous coronary intervention. However, this approach should be viewed as hypothesis generating due to low event rates. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281). Copyright © 2016 American

  12. Elution of monomer from different bulk fill dental composite resins.

    Science.gov (United States)

    Cebe, Mehmet Ata; Cebe, Fatma; Cengiz, Mehmet Fatih; Cetin, Ali Rıza; Arpag, Osman Fatih; Ozturk, Bora

    2015-07-01

    The purpose of this study was to evaluate the elution of Bis-GMA, TEGDMA, HEMA, and Bis-EMA monomers from six bulk fill composite resins over four different time periods, using HPLC. Six different composite resin materials were used in the present study: Tetric Evo Ceram Bulk Fill (Ivoclar Vivadent, Amherst, NY), X-tra Fill (VOCO, Cuxhaven, Germany), Sonic Fill (Kerr, Orange, CA, USA), Filtek Bulk Fill (3M ESPE Dental Product, St. Paul, MN), SDR (Dentsply, Konstanz, Germany), EQUIA (GC America INC, Alsip, IL). The samples (4mm thickness, 5mm diameter) were prepared and polymerized for 20s with a light emitted diode unit. After fabrication, each sample was immediately immersed in 75wt% ethanol/water solution used as extraction fluid and stored in the amber colored bottles at room temperature. Ethanol/water samples were taken (0.5mL) at predefined time intervals:10m (T1), 1h (T2), 24h (T3) and 30 days (T4). These samples were analyzed by HPLC. The obtained data were analyzed with one-way ANOVA and Tukey HSD at significance level of pcomposites (pcomposite resins in all time periods and the amount of eluted monomers was increased with time. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Kelbæk, Henning; Ostojic, Miodrag

    2012-01-01

    The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI).......The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI)....

  14. Impact of Age on Long-Term Outcome After Primary Angioplasty With Bare-Metal or Drug-Eluting Stent (From the DESERT Cooperation)

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Dirksen, Maurits T; Spaulding, Christian

    2013-01-01

    Despite mechanical reperfusion, elderly patients with ST-segment elevation myocardial infarction (STEMI) still experience unsatisfactory outcomes. Drug-eluting stents (DES) have significantly reduced target-vessel revascularization (TVR), but concerns have emerged about the higher risk of late st...... angioplasty and stent implantation included in the Drug-Eluting Stent in Primary Angioplasty (DESERT) Cooperation database. Age was significantly associated with female gender (p...

  15. Monitoring of originated polymer in pure monomer with gradient polymer elution chromatography (GPEC)

    NARCIS (Netherlands)

    Staal, W.J.; Cools, P.J.C.H.; Herk, van A.M.; German, A.L.

    1994-01-01

    The anal. of the amt. of polymer in pure monomer with cloudpoint measurements gives only a qual. answer. Now by use of a liq. chromatograph and gradient elution a fully automated detn. the amt. of polymer can be measured and an impression of the molar mass can be achieved

  16. Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Sabaté, Manel; Windecker, Stephan; Iñiguez, Andres

    2015-01-01

    AIMS: Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential...... to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES...... was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition...

  17. Vorinostat-eluting poly(DL-lactide-co-glycolide nanofiber-coated stent for inhibition of cholangiocarcinoma cells

    Directory of Open Access Journals (Sweden)

    Kwak TW

    2017-10-01

    Full Text Available Tae Won Kwak,1,* Hye Lim Lee,2,* Yeon Hui Song,2 Chan Kim,3 Jungsoo Kim,2 Sol-Ji Seo,2 Young-Il Jeong,2 Dae Hwan Kang2,4 1Medical Convergence Textile Center, Gyeongbuk, Republic of Korea; 2Biomedical Research Institute, Pusan National University Hospital, Pusan, Republic of Korea; 3Amogreentech Co. Ltd. Gyeonggi-do, Republic of Korea; 4Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Gyeongnam, Republic of Korea *These authors contributed equally to this work Purpose: The aim of this study was to fabricate a vorinostat (Zolinza™-eluting nanofiber membrane-coated gastrointestinal (GI stent and to study its antitumor activity against cholangiocarcinoma (CCA cells in vitro and in vivo. Methods: Vorinostat and poly(DL-lactide-co-glycolide dissolved in an organic solvent was sprayed onto a GI stent to make a nanofiber-coated stent using an electro-spinning machine. Intact vorinostat and vorinostat released from nanofibers was used to assess anticancer activity in vitro against various CCA cells. The antitumor activity of the vorinostat-eluting nanofiber membrane-coated stent was evaluated using HuCC-T1 bearing mice. Results: A vorinostat-incorporated polymer nanofiber membrane was formed on the surface of the GI stent. Vorinostat was continuously released from the nanofiber membrane over 10 days, and its release rate was higher in cell culture media than in phosphate-buffered saline. Released vorinostat showed similar anticancer activity against various CCA cells in vitro compared to that of vorinostat. Like vorinostat, vorinostat released from nanofibers induced acetylation of histone H4 and inhibited histone deacetylases 1·3·4/5/7 expression in vitro and in vivo. Furthermore, vorinostat nanofibers showed a higher tumor growth inhibition rate in HuCC-T1 bearing mice than vorinostat injections. Conclusion: Vorinostat-eluting nanofiber membranes showed significant antitumor

  18. RP-HPLC Estimation of Imipramine Hydrochloride and Diazepam in Tablets.

    Science.gov (United States)

    Srikantha, D; Raju, R R

    2015-01-01

    A simple and rapid reversed phase-high performance liquid chromatographic method was developed for simultaneous determination of imipramine hydrochloride and diazepam in pharmaceutical formulations. The elution was done in isocratic mode utilizing a mobile phase consisting of methanol:water:0.1M sodium acetate (30:50:20 v/v/v) on Chromosil C18 column with a flow rate of 1.0 ml/min and with detection at 243 nm. The measured retention time was 3.33±0.02 min for imipramine hydrochloride and 4.64±0.02 min for diazepam. Linearity was measured in the range 25-150 μg/ml for imipramine hydrochloride (r(2)=0.999) and in the range 5-30 μg/ml for diazepam (r(2)=0.9994), respectively. The limits of detection and quantitation were 0.03 and 0.1 μg/ml for imipramine hydrochloride and 0.02 and 0.07 μg/ml for diazepam. Satisfactory validation was also obtained from recovery (100.95-101.52% for imipramine hydrochloride and 99.47-100.33% for diazepam) studies, intraday and interday precision (hydrochloride and diazepam in tablets.

  19. Preparation of paclitaxel/chitosan co-assembled core-shell nanofibers for drug-eluting stent

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Jing; Liu, Yongjia [Instrumental Analysis Center, Shanghai Jiao Tong University, 200240 Shanghai (China); State Key Laboratory of Metal Matrix Composites, School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, 200240 Shanghai (China); Zhu, Bangshang, E-mail: bshzhu@sjtu.edu.cn [Instrumental Analysis Center, Shanghai Jiao Tong University, 200240 Shanghai (China); State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Donghua University, 201620 Shanghai (China); Su, Yue; Zhu, Xinyuan [State Key Laboratory of Metal Matrix Composites, School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, 200240 Shanghai (China)

    2017-01-30

    Highlights: • The core-shell nanofibers (NFs) were made by the co-assembly of paclitaxel (PTX) and chitosan(CS). • The PTX/CS NFs have high PTX loading content, slow drug release and low adherence of platelets. • The PTX/CS NFs have low cytotoxicity and good haemocompatibility. • The PTX/CS NFs which could be easily coated on stents could have potential application for drug eluting stents. - Abstract: The paclitaxel/chitosan (PTX/CS) core-shell nanofibers (NFs) are easily prepared by co-assembly of PTX and CS and used in drug-eluting stent. The mixture solution of PTX (dissolved in ethanol) and CS (dissolved in 1% acetic acid water solution) under sonication will make the formation of NFs, in which small molecule PTX co-assembles with biomacromolecular CS through non-covalent interactions. The obtained NFs are tens to hundreds nanometers in diameter and millimeter level in length. Furthermore, the structure of PTX/CS NFs was characterized by confocal laser scanning microscopy (CLSM), zeta potential, X-ray photoelectron spectroscopy (XPS) and nanoscale infra-red (nanoIR), which provided evidences demonstrated that PTX/CS NFs are core-shell structures. The ‘shell’ of CS wrapped outside of the NFs, while PTX is located in the core. Thus it resulted in high drug loading content (>40 wt.%). The well-controlled drug release, low cytotoxicity and good haemocompatibility were also found in drug carrier system of PTX/CS NFs. In addition, the hydrophilic and flexible properties of NFs make them easily coating and filming on stent to prepare drug-eluting stent (DES). Therefore, this study provides a convenient method to prepare high PTX loaded NFs, which is a promising nano-drug carrier used for DES and other biomedical applications. The possible molecular mechanism of PTX and CS co-assembly and core-shell nanofiber formation is also explored. Statement of significance: We develop a convenient and efficient approach to fabricate core-shell nanofibers (NFs) through

  20. Anti-Inflammatory Effect of Gallic Acid-Eluting Stent in a Porcine Coronary Restenosis Model

    Science.gov (United States)

    Seob Lim, Kyung; Park, Jun-Kyu; Ho Jeong, Myung; Ho Bae, In; Sung Park, Dae; Won Shim, Jae; Ha Kim, Jung; Kuk Kim, Hyun; Soo Kim, Sung; Sun Sim, Doo; Joon Hong, Young; Han Kim, Ju; Ahn, Youngkeun

    2018-01-01

    Background Gallic acid (3,4,5-trihydroxybenzoic acid) is a natural polyphenol and strong natural antioxidant found abundantly in red wine and green tea. The aim of this study was to examine the anti-inflammatory effect of a novel gallic acid-eluting stent in a porcine coronary restenosis model. Methods Fifteen pigs were randomized into three groups; in which a total of 30 coronary arteries (10 in each group) were implanted with gallic acid-eluting stents (GESs, n = 10), gallic acid and sirolimus-eluting stents (GSESs, n = 10), or sirolimus-eluting stents (SESs, n = 10). Histopathologic analysis was performed 28 days after stenting. Results There were no significant differences in injury score and fibrin score among the groups, however there were significant differences in the internal elastic lamina (4.0 ± 0.83 mm2 in GES vs. 3.0 ± 0.53 mm2 in GSES vs. 4.6 ± 1.43 mm2 in SES, p < 0.0001), lumen area (2.3 ± 0.49 mm2 in GES vs. 1.9 ± 0.67 mm2 in GSES vs. 2.9 ± 0.56 mm2 in SES, p < 0.0001), neointimal area (1.7 ± 0.63 mm2 in GES vs. 1.1 ± 0.28 mm2 in GSES vs. 1.7 ± 1.17 mm2 in SES, p < 0.05), and percent area of stenosis (42.4% ± 9.22% in GES vs. 38.2% ± 12.77% in GSES vs. 33.9% ± 15.64% in SES, p < 0.05). The inflammation score was significantly lower in the GES and GSES groups compared to that in the SES group [1.0 (range: 1.0 to 2.0) in GES vs. 1.0 (range: 1.0 to 1.0) in GSES vs. 1.5 (range: 1.0 to 3.0) in SES, p < 0.05]. Conclusions The GES group had a greater percent area of stenosis than the SES group. Although gallic acid in the GES and GSES groups did not show a synergistic effect in suppressing neointimal hyperplasia, it resulted in greater inhibition of the inflammatory reaction in the porcine coronary restenosis model than in the SES group. PMID:29844643

  1. Time-Fractional Advection-Dispersion Equation (tFADE) to Quantify Aqueous Phase Contaminant Elution from a Trichloroethene (TCE) NAPL Source Zone in Sand Columns

    Science.gov (United States)

    Tick, G. R.; Wei, S.; Sun, H.; Zhang, Y.

    2016-12-01

    Pore-scale heterogeneity, NAPL distribution, and sorption/desorption processes can significantly affect aqueous phase elution and mass flux in porous media systems. The application of a scale-independent fractional derivative model (tFADE) was used to simulate elution curves for a series of columns (5 cm, 7 cm, 15 cm, 25 cm, and 80 cm) homogeneously packed with 20/30-mesh sand and distributed with uniform saturations (7-24%) of NAPL phase trichloroethene (TCE). An additional set of columns (7 cm and 25 cm) were packed with a heterogeneous distribution of quartz sand upon which TCE was emplaced by imbibing the immiscible liquid, under stable displacement conditions, to simulate a spill-type process. The tFADE model was able to better represent experimental elution behavior for systems that exhibited extensive long-term concentration tailing requiring much less parameters compared to typical multi-rate mass transfer models (MRMT). However, the tFADE model was not able to effectively simulate the entire elution curve for such systems with short concentration tailing periods since it assumes a power-law distribution for the dissolution rate for TCE. Such limitations may be solved using the tempered fractional derivative model, which can capture the single-rate mass transfer process and therefore the short elution concentration tailing behavior. Numerical solution for the tempered fractional-derivative model in bounded domains however remains a challenge and therefore requires further study. However, the tFADE model shows excellent promise for understanding impacts on concentration elution behavior for systems in which physical heterogeneity, non-uniform NAPL distribution, and pronounced sorption-desorption effects dominate or are present.

  2. A simple elution strategy for biotinylated proteins bound to streptavidin conjugated beads using excess biotin and heat.

    Science.gov (United States)

    Cheah, Joleen S; Yamada, Soichiro

    2017-12-02

    Protein-protein interactions are the molecular basis of cell signaling. Recently, proximity based biotin identification (BioID) has emerged as an alternative approach to traditional co-immunoprecipitation. In this protocol, a mutant biotin ligase promiscuously labels proximal binding partners with biotin, and resulting biotinylated proteins are purified using streptavidin conjugated beads. This approach does not require preservation of protein complexes in vitro, making it an ideal approach to identify transient or weak protein complexes. However, due to the high affinity bond between streptavidin and biotin, elution of biotinylated proteins from streptavidin conjugated beads requires harsh denaturing conditions, which are often incompatible with downstream processing. To effectively release biotinylated proteins bound to streptavidin conjugated beads, we designed a series of experiments to determine optimal binding and elution conditions. Interestingly, the concentrations of SDS and IGEPAL-CA630 during the incubation with streptavidin conjugated beads were the key to effective elution of biotinylated proteins using excess biotin and heating. This protocol provides an alternative method to isolate biotinylated proteins from streptavidin conjugated beads that is suitable for further downstream analysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Studies of techniques for the post-elution concentration of 99mTc obtained from gel type 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Suzuki, Katia Noriko

    2009-01-01

    On average 80% of the radiopharmaceuticals used in Nuclear Medicine are labeled with 99 mTc due to its physical properties and easy attainment through of 99 Mo/ 99 mTc generators. The Directory of Radiopharmacy (DIRF) of IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with 99 Mo produced by 98 Mo(n,γ) 99 Mo reaction that occurs at the IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 mL with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (25 mCi)/mL. The fission generator gives a higher radioactive concentration around 1850 MBq (50 mCi)/mL. The aim of this work is to study a system of post-elution concentration of 99 mTc for the attainment of a high enough radioactive concentration to meet the demands of the market, with a proved quality. Two types of systems of post-elution concentration were developed: the single and the tandem. The most appropriate system for the gel generator of 99 Mo/ 99 mTc, being at the same time sterile and vacuum automated, was the tandem system using Dionex 2.5 cc/QMA cartridges. The gel generator is eluted with 10 mL of solution of 0.1% NaCl and the pertechnetate anion is retained in the QMA cartridge and further eluted with 4 mL of saline. The process takes no more than 30 minutes. The elution efficiency of the system of concentration was 90 %. At the beginning of 2009 a global crisis in the supply of 99 Mo took place making it necessary the development of alternative technologies for the production of 99 Mo/ 99 mTc generators using fission produced 99 Mo and the development of an appropriate method to extend the useful life of this generator. The results of this study showed that the same system developed for the post- concentration of the gel generator can be employed for the fission generator, using the tandem system, giving a concentration factor of 3 for the elution of 99 mTc. (author)

  4. pH-zone-refining elution-extrusion countercurrent chromatography: Separation of hydroxyanthraquinones from Cassiae semen.

    Science.gov (United States)

    Bu, Zhisi; Lv, Liqiong; Li, Xingnuo; Chu, Chu; Tong, Shengqiang

    2017-11-01

    Seven hydroxyanthraquinones were successfully separated from the traditional Chinese medicinal herb Cassiae semen by conventional and pH-zone-refining countercurrent chromatography with an environmentally friendly biphasic solvent system, in which elution-extrusion mode was investigated for pH-zone-refining countercurrent chromatography for the first time. A two-phase solvent system composed of n-hexane/ethyl acetate/ethanol/water (5:3:4:4, v/v/v/v) was used for the conventional countercurrent chromatography while the same system with a different volume ratio n-hexane/ethyl acetate/ethanol/water (3:5:2:6, v/v/v/v) was used for pH-zone-refining countercurrent chromatography, in which 20 mmol/L of trifluoroacetic acid was added in the organic phase as a retainer and 15 mmol/L of ammonia was added to the aqueous phase as an eluter. A 400 mg crude sample could be well separated by pH-zone-refining countercurrent chromatography, yielding 53 mg of aurantio-obtusin, 40 mg of chryso-obtusin, 18 mg of obtusin, 24 mg of obtusifolin, 10 mg of emodin, and 105 mg of the mixture of chrysophanol and physcion with a purity of over 95.8, 95.7, 96.9, 93.5, 97.4, 77.1, and 19.8%, as determined by high-performance liquid chromatography. Furthermore, the difference in elution sequence between conventional and pH-zone-refining mode was observed and discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. In vitro haematic proteins adsorption and cytocompatibility study on acrylic copolymer to realise coatings for drug-eluting stents

    International Nuclear Information System (INIS)

    Gagliardi, Mariacristina

    2012-01-01

    In the present paper, a preliminary in vitro analysis of biocompatibility of newly-synthesised acrylic copolymers is reported. In particular, with the aim to obtain coatings for drug-eluting stents, blood protein absorption and cytocompatibility were studied. For protein absorption tests, bovine serum albumin and bovine plasma fibrinogen were considered. Cytocompatibility was tested using C2C12 cell line as model, analysing the behaviour of polymeric matrices and of drug-eluting systems, obtained loading polymeric matrices with paclitaxel, an anti-mitotic drug, in order to evaluate the efficacy of a pharmacological treatment locally administered from these materials. Results showed that the amount of albumin absorbed was greater than the amount of fibrinogen (comprised in the range of 70%–85% and 10%–22% respectively) and it is a good behaviour in terms of haemocompatibility. Cell culture tests showed good adhesion properties and a relative poor proliferation. In addition, a strong effect related to drug elution and a correlation with the macromolecular composition were detected. In this preliminary analysis, tested materials showed good characteristics and can be considered possible candidates to obtain coatings for drug-eluting stents. Highlights: ► Preliminary evaluation of haemo- and cytocompatibility of newly-synthesised acrylic copolymers ► Materials adsorb higher amounts of albumin and with a faster rate than fibrinogen. ► Protein adsorption depended on the macromolecular composition and surface properties. ► Cell viability on pure samples and efficacy of paclitaxel release were verified in C2C12 cultures.

  6. In vitro haematic proteins adsorption and cytocompatibility study on acrylic copolymer to realise coatings for drug-eluting stents

    Energy Technology Data Exchange (ETDEWEB)

    Gagliardi, Mariacristina, E-mail: mariacristina.gagliardi@iit.it

    2012-12-01

    In the present paper, a preliminary in vitro analysis of biocompatibility of newly-synthesised acrylic copolymers is reported. In particular, with the aim to obtain coatings for drug-eluting stents, blood protein absorption and cytocompatibility were studied. For protein absorption tests, bovine serum albumin and bovine plasma fibrinogen were considered. Cytocompatibility was tested using C2C12 cell line as model, analysing the behaviour of polymeric matrices and of drug-eluting systems, obtained loading polymeric matrices with paclitaxel, an anti-mitotic drug, in order to evaluate the efficacy of a pharmacological treatment locally administered from these materials. Results showed that the amount of albumin absorbed was greater than the amount of fibrinogen (comprised in the range of 70%-85% and 10%-22% respectively) and it is a good behaviour in terms of haemocompatibility. Cell culture tests showed good adhesion properties and a relative poor proliferation. In addition, a strong effect related to drug elution and a correlation with the macromolecular composition were detected. In this preliminary analysis, tested materials showed good characteristics and can be considered possible candidates to obtain coatings for drug-eluting stents. Highlights: Black-Right-Pointing-Pointer Preliminary evaluation of haemo- and cytocompatibility of newly-synthesised acrylic copolymers Black-Right-Pointing-Pointer Materials adsorb higher amounts of albumin and with a faster rate than fibrinogen. Black-Right-Pointing-Pointer Protein adsorption depended on the macromolecular composition and surface properties. Black-Right-Pointing-Pointer Cell viability on pure samples and efficacy of paclitaxel release were verified in C2C12 cultures.

  7. Clinical results with the Resolute zotarolimus-eluting stent in total coronary occlusions

    DEFF Research Database (Denmark)

    Kelbæk, Henning; Holmvang, Lene; Richardt, Gert

    2015-01-01

    Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods and resu......Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods...... lesion revascularisation) and Academic Research Consortium definite or probable stent thrombosis. The rate of TLF at two years was not significantly different among patients in the CTO (9.1%), TO (9.8%), and no occlusion (10.4%) groups (log-rank p=0.800); neither were the components of TLF. Definite...... or probable stent thrombosis occurred more frequently in the TO group (2.8% vs. 1.2% in the CTO and 1.1% in the group with no occlusion, p=0.027). There were 10 late and six very late stent thrombosis events. Conclusions: Apart from a higher rate of stent thrombosis in patients with TO, patients with totally...

  8. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials.

    Science.gov (United States)

    Muramatsu, Takashi; Onuma, Yoshinobu; van Geuns, Robert-Jan; Chevalier, Bernard; Patel, Tejas M; Seth, Ashok; Diletti, Roberto; García-García, Hector M; Dorange, Cécile C; Veldhof, Susan; Cheong, Wai-Fung; Ozaki, Yukio; Whitbourn, Robert; Bartorelli, Antonio; Stone, Gregg W; Abizaid, Alexandre; Serruys, Patrick W

    2014-05-01

    The aim of this study was to evaluate 1-year clinical outcomes of diabetic patients treated with the Absorb bioresorbable vascular scaffold (BVS). Clinical outcomes of diabetic patients after BVS implantation have been unreported. This study included 101 patients in the ABSORB Cohort B trial and the first consecutive 450 patients with 1 year of follow-up in the ABSORB EXTEND trial. A total of 136 diabetic patients were compared with 415 nondiabetic patients. In addition, 882 diabetic patients treated with everolimus-eluting metal stents (EES) in pooled data from the SPIRIT trials (SPIRIT FIRST [Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT II [A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT III [Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System (EECSS)], SPIRIT IV Clinical Trial [Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System]) were used for the comparison by applying propensity score matching. The primary endpoint was a device-oriented composite endpoint (DoCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1-year follow-up. The cumulative incidence of DoCE did not differ between diabetic and nondiabetic patients treated with the BVS (3.7% vs. 5.1%, p = 0.64). Diabetic patients treated with the BVS had a similar incidence of the DoCE compared with diabetic patients treated with EES in the matched study group (3.9% for the BVS vs. 6.4% for EES, p = 0.38). There were no differences in the incidence of definite or probable scaffold/stent thrombosis (0.7% for both diabetic and nondiabetic patients with the BVS; 1.0% for diabetic patients with the BVS vs. 1.7% for diabetic patients with EES in the matched study group). In the present analyses, diabetic patients treated with the BVS showed similar rates of DoCEs compared with nondiabetic patients treated with the BVS and

  9. First-Generation Versus Second-Generation Drug-Eluting Stents in Coronary Chronic Total Occlusions: Two-Year Results of a Multicenter Registry.

    Directory of Open Access Journals (Sweden)

    Jong-Hwa Ahn

    Full Text Available Limited data are available regarding the long-term clinical outcomes of second-generation drug-eluting stents (DES versus first-generation DES in patients with coronary chronic total occlusion (CTO who undergo percutaneous coronary intervention (PCI. The aim of this study was to compare the clinical outcomes of second-generation DES with those of first-generation DES for the treatment of CTO.Between March 2003 and February 2012, 1,006 consecutive patients with CTO who underwent successful PCI using either first-generation DES (n = 557 or second-generation DES (n = 449 were enrolled in a multicenter, observational registry. Propensity-score matching was also performed. The primary outcome was cardiac death over a 2-year follow-up period. No significant differences were observed between the two groups regarding the incidence of cardiac death (first-generation DES versus second-generation DES; 2.5% vs 2.0%; hazard ratio [HR]: 0.86; 95% confidence interval [CI]: 0.37 to 1.98; p = 0.72 or major adverse cardiac events (MACE, 11.8% vs 11.4%; HR: 1.00; 95% CI: 0.67 to 1.50; p = 0.99. After propensity score matching, the incidences of cardiac death (HR: 0.86; 95% CI: 0.35 to 2.06; p = 0.86 and MACE (HR: 0.93; 95% CI: 0.63 to 1.37; p = 0.71 were still similar in both groups. Furthermore, no significant differences were observed between sirolimus-eluting, paclitaxel-eluting, zotarolimus-eluting, and everolimus-eluting stents regarding the incidence of cardiac death or MACE.This study shows that the efficacy of second-generation DES is comparable to that of first-generation DES for treatment of CTO over 2 years of follow-up.

  10. Investigation of Processes Controlling Elution of Solutes from Nonaqueous Phase Liquid (NAPL) Pools into Groundwater

    Science.gov (United States)

    Seyedabbasi, M.; Pirestani, K.; Holland, S. B.; Imhoff, P. T.

    2005-12-01

    Two major processes influencing the elution of solutes from porous media contaminated with nonaqueous phase liquids (NAPLs) are external mass transfer between the NAPL and groundwater and internal diffusion through NAPL ganglia and pools. There is a relatively large body of literature on the dissolution of single-species NAPLs. Less is known about the rates of elution of compounds dissolving from multicomponent NAPLs. We examined the mass transfer of one solute, 2,3-dimethyl-2-butanol (DMB) - a partitioning tracer, between groundwater and a dense NAPL - trichloroethylene (TCE). Diffusion cell experiments were used to measure the molecular diffusion coefficient of DMB in pure TCE and in porous media contaminated with a TCE pool. Measured diffusion coefficients were compared with empirical correlations (pure TCE) and a parallel resistance model (TCE pool). Based on the results from these analyses, a dimensionless Biot number was derived to express the ratio of the external rate of mass transfer from a NAPL pool to the internal rate of diffusion within the pool, which varies with NAPL saturation and NAPL-water partition coefficient. Biot numbers were then estimated for several laboratory scale experiments involving DMB transport between NAPL pools and groundwater. The estimated Biot numbers were in good agreement with experimental results. The expression for the Biot number developed here may be used to assess the processes controlling the elution of solutes from NAPL pools, which has implications on long-term predictions of solute dissolution from NAPLs in the field.

  11. Vorinostat-eluting poly(DL-lactide-co-glycolide) nanofiber-coated stent for inhibition of cholangiocarcinoma cells.

    Science.gov (United States)

    Kwak, Tae Won; Lee, Hye Lim; Song, Yeon Hui; Kim, Chan; Kim, Jungsoo; Seo, Sol-Ji; Jeong, Young-Il; Kang, Dae Hwan

    2017-01-01

    The aim of this study was to fabricate a vorinostat (Zolinza™)-eluting nanofiber membrane-coated gastrointestinal (GI) stent and to study its antitumor activity against cholangiocarcinoma (CCA) cells in vitro and in vivo. Vorinostat and poly(DL-lactide-co-glycolide) dissolved in an organic solvent was sprayed onto a GI stent to make a nanofiber-coated stent using an electro-spinning machine. Intact vorinostat and vorinostat released from nanofibers was used to assess anticancer activity in vitro against various CCA cells. The antitumor activity of the vorinostat-eluting nanofiber membrane-coated stent was evaluated using HuCC-T1 bearing mice. A vorinostat-incorporated polymer nanofiber membrane was formed on the surface of the GI stent. Vorinostat was continuously released from the nanofiber membrane over 10 days, and its release rate was higher in cell culture media than in phosphate-buffered saline. Released vorinostat showed similar anticancer activity against various CCA cells in vitro compared to that of vorinostat. Like vorinostat, vorinostat released from nanofibers induced acetylation of histone H4 and inhibited histone deacetylases 1⋅3⋅4/5/7 expression in vitro and in vivo. Furthermore, vorinostat nanofibers showed a higher tumor growth inhibition rate in HuCC-T1 bearing mice than vorinostat injections. Vorinostat-eluting nanofiber membranes showed significant antitumor activity against CCA cells in vitro and in vivo. We suggest the vorinostat nanofiber-coated stent may be a promising candidate for CCA treatment.

  12. Method developments approaches in supercritical fluid chromatography applied to the analysis of cosmetics.

    Science.gov (United States)

    Lesellier, E; Mith, D; Dubrulle, I

    2015-12-04

    Analyses of complex samples of cosmetics, such as creams or lotions, are generally achieved by HPLC. These analyses are often multistep gradients, due to the presence of compounds with a large range of polarity. For instance, the bioactive compounds may be polar, while the matrix contains lipid components that are rather non-polar, thus cosmetic formulations are usually oil-water emulsions. Supercritical fluid chromatography (SFC) uses mobile phases composed of carbon dioxide and organic co-solvents, allowing for good solubility of both the active compounds and the matrix excipients. Moreover, the classical and well-known properties of these mobile phases yield fast analyses and ensure rapid method development. However, due to the large number of stationary phases available for SFC and to the varied additional parameters acting both on retention and separation factors (co-solvent nature and percentage, temperature, backpressure, flow rate, column dimensions and particle size), a simplified approach can be followed to ensure a fast method development. First, suited stationary phases should be carefully selected for an initial screening, and then the other operating parameters can be limited to the co-solvent nature and percentage, maintaining the oven temperature and back-pressure constant. To describe simple method development guidelines in SFC, three sample applications are discussed in this paper: UV-filters (sunscreens) in sunscreen cream, glyceryl caprylate in eye liner and caffeine in eye serum. Firstly, five stationary phases (ACQUITY UPC(2)) are screened with isocratic elution conditions (10% methanol in carbon dioxide). Complementary of the stationary phases is assessed based on our spider diagram classification which compares a large number of stationary phases based on five molecular interactions. Secondly, the one or two best stationary phases are retained for further optimization of mobile phase composition, with isocratic elution conditions or, when

  13. Efficient Separation of Lanthanides Using Poly (Styrene-Divinyl Benzene) Aminated Anion Exchanger

    International Nuclear Information System (INIS)

    Borai, E.H.; Hassan, R.S.; El- Dessouky, M.I.; Ghonem, A.

    2008-01-01

    New chromatographic method was developed for the determination and separation of lanthanides using AS4A anionic column. The behavior of the column towards lanthanides was studied through many parameters, From the data obtained it is found that, affinity of the column toward investigated ions increase by increasing eluent concentration and it decrease retention factors. With the two investigated eluent (oxalic and citric acids), elution order for lanthanide elements was obtained in their atomic number from La to Lu. Retention times and retention orders obtained at these conditions clearly show that, lanthanides in AS4A are displaced according to anion exchange mechanism. More over separation of lanthanides using AS4A was studied using isocratic and gradient elution programs. Light and the first intermediate lanthanide elements were separated successfully by applying a gradient program containing 70% oxalic acid (100 mM) and 30% water. The problem of separation for heavy and the last intermediate lanthanide elements was solved using 100 mM alpha hydroxy isobutyric acid (α-HIBA)

  14. Determination of theobromine, theophylline, and caffeine in by-products of cupuacu and cacao seeds by high-performance liquid chromatography.

    Science.gov (United States)

    Lo Coco, F; Lanuzza, F; Micali, G; Cappellano, G

    2007-01-01

    Theobromine, theophylline, and caffeine are determined simultaneously by a rapid and selective reversed-phase high-performance liquid chromatography (HPLC) method with UV detection in by-products of cupuacu and cacao seeds. The determination is carried out in the raw and roasted ground cupuacu seeds and in the corresponding powders obtained after pressure treatment. The by-products of both cupuacu seeds and cacao seeds are obtained under the same technological conditions. The HPLC method uses isocratic elution with a mobile phase of methanol-water-acetic acid (80:19:1) (v/v) at a flow rate of 1 mL/min and UV absorbance detection at 275 nm. Total elution time for these analytes is less than 10 min, and the detection limit for all analytes is 0.1 mg/g. The amounts of theobromine and caffeine found in all the cupuacu samples are one or more orders of magnitude lower than those from cacao. Theophylline is found in all cacao samples except for the roasted ground paste, and it is only found in the roasted ground paste in the cupuacu samples.

  15. Adding functionality with additive manufacturing: Fabrication of titanium-based antibiotic eluting implants

    Energy Technology Data Exchange (ETDEWEB)

    Cox, Sophie C. [School of Chemical Engineering, University of Birmingham, Edgbaston B15 2TT (United Kingdom); Jamshidi, Parastoo [School of Materials and Metallurgy, University of Birmingham, Edgbaston B15 2TT (United Kingdom); Eisenstein, Neil M. [School of Chemical Engineering, University of Birmingham, Edgbaston B15 2TT (United Kingdom); Royal Centre for Defence Medicine, Birmingham Research Park, Vincent Drive, Edgbaston B15 2SQ (United Kingdom); Webber, Mark A. [School of Biosciences, University of Birmingham, Edgbaston B15 2TT (United Kingdom); Hassanin, Hany [School of Materials and Metallurgy, University of Birmingham, Edgbaston B15 2TT (United Kingdom); School of Mechanical and Automotive Engineering, Kingston University, London SW15 3DW (United Kingdom); Attallah, Moataz M. [School of Materials and Metallurgy, University of Birmingham, Edgbaston B15 2TT (United Kingdom); Shepherd, Duncan E.T. [Department of Mechanical Engineering, School of Engineering, University of Birmingham, Edgbaston B15 2TT (United Kingdom); Addison, Owen [School of Dentistry, University of Birmingham, Edgbaston B15 2TT (United Kingdom); Grover, Liam M. [School of Chemical Engineering, University of Birmingham, Edgbaston B15 2TT (United Kingdom)

    2016-07-01

    Additive manufacturing technologies have been utilised in healthcare to create patient-specific implants. This study demonstrates the potential to add new implant functionality by further exploiting the design flexibility of these technologies. Selective laser melting was used to manufacture titanium-based (Ti-6Al-4V) implants containing a reservoir. Pore channels, connecting the implant surface to the reservoir, were incorporated to facilitate antibiotic delivery. An injectable brushite, calcium phosphate cement, was formulated as a carrier vehicle for gentamicin. Incorporation of the antibiotic significantly (p = 0.01) improved the compressive strength (5.8 ± 0.7 MPa) of the cement compared to non-antibiotic samples. The controlled release of gentamicin sulphate from the calcium phosphate cement injected into the implant reservoir was demonstrated in short term elution studies using ultraviolet-visible spectroscopy. Orientation of the implant pore channels were shown, using micro-computed tomography, to impact design reproducibility and the back-pressure generated during cement injection which ultimately altered porosity. The amount of antibiotic released from all implant designs over a 6 hour period (< 28% of the total amount) were found to exceed the minimum inhibitory concentrations of Staphylococcus aureus (16 μg/mL) and Staphylococcus epidermidis (1 μg/mL); two bacterial species commonly associated with periprosthetic infections. Antibacterial efficacy was confirmed against both bacterial cultures using an agar diffusion assay. Interestingly, pore channel orientation was shown to influence the directionality of inhibition zones. Promisingly, this work demonstrates the potential to additively manufacture a titanium-based antibiotic eluting implant, which is an attractive alternative to current treatment strategies of periprosthetic infections. - Highlights: • Titanium implants were additively manufactured with surface connected reservoirs. • Implants

  16. Adding functionality with additive manufacturing: Fabrication of titanium-based antibiotic eluting implants

    International Nuclear Information System (INIS)

    Cox, Sophie C.; Jamshidi, Parastoo; Eisenstein, Neil M.; Webber, Mark A.; Hassanin, Hany; Attallah, Moataz M.; Shepherd, Duncan E.T.; Addison, Owen; Grover, Liam M.

    2016-01-01

    Additive manufacturing technologies have been utilised in healthcare to create patient-specific implants. This study demonstrates the potential to add new implant functionality by further exploiting the design flexibility of these technologies. Selective laser melting was used to manufacture titanium-based (Ti-6Al-4V) implants containing a reservoir. Pore channels, connecting the implant surface to the reservoir, were incorporated to facilitate antibiotic delivery. An injectable brushite, calcium phosphate cement, was formulated as a carrier vehicle for gentamicin. Incorporation of the antibiotic significantly (p = 0.01) improved the compressive strength (5.8 ± 0.7 MPa) of the cement compared to non-antibiotic samples. The controlled release of gentamicin sulphate from the calcium phosphate cement injected into the implant reservoir was demonstrated in short term elution studies using ultraviolet-visible spectroscopy. Orientation of the implant pore channels were shown, using micro-computed tomography, to impact design reproducibility and the back-pressure generated during cement injection which ultimately altered porosity. The amount of antibiotic released from all implant designs over a 6 hour period (< 28% of the total amount) were found to exceed the minimum inhibitory concentrations of Staphylococcus aureus (16 μg/mL) and Staphylococcus epidermidis (1 μg/mL); two bacterial species commonly associated with periprosthetic infections. Antibacterial efficacy was confirmed against both bacterial cultures using an agar diffusion assay. Interestingly, pore channel orientation was shown to influence the directionality of inhibition zones. Promisingly, this work demonstrates the potential to additively manufacture a titanium-based antibiotic eluting implant, which is an attractive alternative to current treatment strategies of periprosthetic infections. - Highlights: • Titanium implants were additively manufactured with surface connected reservoirs. • Implants

  17. Advantages of novel BioMimeTM Sirolimus Eluting Coronary Stent system. Moving towards biomimicry.

    Science.gov (United States)

    Upendra, K; Sanjeev, B

    2012-02-01

    Since the first reported use of percutaneous transluminal coronary angioplasty (PTCA), advancements in interventional cardiology arena have been fast paced. Within the last ten years, these developments have been exponential. Developers & clinicians are fast adapting from the learning curve awarded by the time course of DES evolution. In that light BioMimeTM Sirolimus Eluting Coronary Stent comes as a fresh thought in taking stents towards a biomimicry concept. The stent is built on an ultra-low strut thickness (65 µm) cobalt chromium stent platform, using an intelligent hybrid of close and open cells allowing for morphology mediated expansion, employs a well known anti-proliferative - Sirolimus that elutes from a biodegradable co-polymer formulation in 30 days and ensures high coating integrity and low coating thickness of 2 µm. The resultant stent demonstrates almost 100% endothelialization at 30 days in preclinical model and zero percent MACE >18 months in the primary efficacy and safety clinical study.

  18. Everolimus-induced Pneumonitis after Drug-eluting Stent Implantation: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Susumu, E-mail: susumu1029@gmail.com; Kikuchi, Naoshi; Ichikawa, Atsuo; Sano, Go; Satoh, Keita; Sugino, Keishi; Isobe, Kazutoshi; Takai, Yujiro [Toho University School of Medicine, Department of Respiratory Medicine (Japan); Shibuya, Kazutoshi [Toho University School of Medicine, Department of Pathology (Japan); Homma, Sakae [Toho University School of Medicine, Department of Respiratory Medicine (Japan)

    2013-08-01

    Despite the wide use of everolimus as an antineoplastic coating agent for coronary stents to reduce the rate of restenosis, little is known about the health hazards of everolimus-eluting stents (EES). We describe a case of pneumonitis that developed 2 months after EES implantation for angina. Lung pathology demonstrated an organizing pneumonia pattern that responded to corticosteroid therapy. Although the efficacy of EES for ischemic heart disease is well established, EES carries a risk of pneumonitis.

  19. Protein Detection Using the Multiplexed Proximity Extension Assay (PEA) from Plasma and Vaginal Fluid Applied to the Indicating FTA Elute Micro Card™

    Science.gov (United States)

    Berggrund, Malin; Ekman, Daniel; Gustavsson, Inger; Sundfeldt, Karin; Olovsson, Matts; Enroth, Stefan; Gyllensten, Ulf

    2016-01-01

    The indicating FTA elute micro card™ has been developed to collect and stabilize the nucleic acid in biological samples and is widely used in human and veterinary medicine and other disciplines. This card is not recommended for protein analyses, since surface treatment may denature proteins. We studied the ability to analyse proteins in human plasma and vaginal fluid as applied to the indicating FTA elute micro card™ using the sensitive proximity extension assay (PEA). Among 92 proteins in the Proseek Multiplex Oncology Iv2 panel, 87 were above the limit of detection (LOD) in liquid plasma and 56 among 92 above LOD in plasma applied to FTA cards. Washing and protein elution protocols were compared to identify an optimal method. Liquid-based cytology samples showed a lower number of proteins above LOD than FTA cards with vaginal fluid samples applied. Our results demonstrate that samples applied to the indicating FTA elute micro card™ are amendable to protein analyses, given that a sensitive protein detection assay is used. The results imply that biological samples applied to FTA cards can be used for DNA, RNA and protein detection. PMID:28936257

  20. Protein Detection Using the Multiplexed Proximity Extension Assay (PEA from Plasma and Vaginal Fluid Applied to the Indicating FTA Elute Micro Card™

    Directory of Open Access Journals (Sweden)

    Malin Berggrund

    2016-01-01

    Full Text Available The indicating FTA elute micro card™ has been developed to collect and stabilize the nucleic acid in biological samples and is widely used in human and veterinary medicine and other disciplines. This card is not recommended for protein analyses, since surface treatment may denature proteins. We studied the ability to analyse proteins in human plasma and vaginal fluid as applied to the indicating FTA elute micro card™ using the sensitive proximity extension assay (PEA. Among 92 proteins in the Proseek Multiplex Oncology Iv2 panel, 87 were above the limit of detection (LOD in liquid plasma and 56 among 92 above LOD in plasma applied to FTA cards. Washing and protein elution protocols were compared to identify an optimal method. Liquid-based cytology samples showed a lower number of proteins above LOD than FTA cards with vaginal fluid samples applied. Our results demonstrate that samples applied to the indicating FTA elute micro card™ are amendable to protein analyses, given that a sensitive protein detection assay is used. The results imply that biological samples applied to FTA cards can be used for DNA, RNA and protein detection.

  1. Protein Detection Using the Multiplexed Proximity Extension Assay (PEA) from Plasma and Vaginal Fluid Applied to the Indicating FTA Elute Micro Card™.

    Science.gov (United States)

    Berggrund, Malin; Ekman, Daniel; Gustavsson, Inger; Sundfeldt, Karin; Olovsson, Matts; Enroth, Stefan; Gyllensten, Ulf

    2016-01-01

    The indicating FTA elute micro card™ has been developed to collect and stabilize the nucleic acid in biological samples and is widely used in human and veterinary medicine and other disciplines. This card is not recommended for protein analyses, since surface treatment may denature proteins. We studied the ability to analyse proteins in human plasma and vaginal fluid as applied to the indicating FTA elute micro card™ using the sensitive proximity extension assay (PEA). Among 92 proteins in the Proseek Multiplex Oncology Iv2 panel, 87 were above the limit of detection (LOD) in liquid plasma and 56 among 92 above LOD in plasma applied to FTA cards. Washing and protein elution protocols were compared to identify an optimal method. Liquid-based cytology samples showed a lower number of proteins above LOD than FTA cards with vaginal fluid samples applied. Our results demonstrate that samples applied to the indicating FTA elute micro card™ are amendable to protein analyses, given that a sensitive protein detection assay is used. The results imply that biological samples applied to FTA cards can be used for DNA, RNA and protein detection.

  2. FTA card utility for PCR detection of Mycobacterium leprae.

    Science.gov (United States)

    Aye, Khin Saw; Matsuoka, Masanori; Kai, Masanori; Kyaw, Kyaw; Win, Aye Aye; Shwe, Mu Mu; Thein, Min; Htoo, Maung Maung; Htoon, Myo Thet

    2011-01-01

    The suitability of the FTA® elute card for the collection of slit skin smear (SSS) samples for PCR detection of Mycobacterium leprae was evaluated. A total of 192 SSS leprosy samples, of bacillary index (BI) 1 to 5, were collected from patients attending two skin clinics in Myanmar and preserved using both FTA® elute cards and 70% ethanol tubes. To compare the efficacy of PCR detection of DNA from each BI class, PCR was performed to amplify an M. leprae-specific repetitive element. Of the 192 samples, 116 FTA® elute card and 112 70% ethanol samples were PCR positive for M. leprae DNA. When correlated with BI, area under the curve (AUC) values of the respective receiver-operating characteristic curves were similar for the FTA® elute card and ethanol collection methods (AUC=0.6). Taken together, our results indicate that the FTA® elute card, which enables the collection, transport, and archiving of clinical samples, is an attractive alternative to ethanol preservation for the detection of M. leprae DNA.

  3. Determinação de 3,4-metilenodioximetanfetamina (MDMA em comprimidos de Ecstasy por cromatografia líquida de alta eficiência com detecção por fluorescência (CLAE-DF Determination of 3,4-methylenedioxymethamphetamine (MDMA in Ecstasy tablets by high performance liquid chromatography with fluorescence detection (HPLC-FD

    Directory of Open Access Journals (Sweden)

    José Luiz da Costa

    2009-01-01

    Full Text Available This paper describes the development and validation of simple and selective analytical method for determination of 3.4-methylenedioxymethamphetamine (MDMA in Ecstasy tablets, using high performance liquid chromatography with fluorescence detection. Analysis was performed in a reversed phase column (LiChrospher 100 C18, 150 x 4.6 mm, 5 µm, isocratic elution with phosphate buffer 25 mmol/L pH 3.0 and acetonitrile (95:5, v/v. The method presents adequate linearity, selectivity, precision and accuracy. MDMA concentration in analyzed tablets showed a remarkable variability (from 8.5 to 59.5 mg/tablet although the tablet weights were uniform, indicating poor manufacturing control thus imposing additional health risks to the users.

  4. A narrow open tubular column for high efficiency liquid chromatographic separation.

    Science.gov (United States)

    Chen, Huang; Yang, Yu; Qiao, Zhenzhen; Xiang, Piliang; Ren, Jiangtao; Meng, Yunzhu; Zhang, Kaiqi; Juan Lu, Joann; Liu, Shaorong

    2018-04-30

    We report a great feature of open tubular liquid chromatography when it is run using an extremely narrow (e.g., 2 μm inner diameter) open tubular column: more than 10 million plates per meter can be achieved in less than 10 min and under an elution pressure of ca. 20 bar. The column is coated with octadecylsilane and both isocratic and gradient separations are performed. We reveal a focusing effect that may be used to interpret the efficiency enhancement. We also demonstrate the feasibility of using this technique for separating complex peptide samples. This high-resolution and fast separation technique is promising and can lead to a powerful tool for trace sample analysis.

  5. Study of the elution {sup 99}Mo-{sup 99m}Tc generators produced at IPEN-CNEN/SP

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Paula Regina Corain [Pontificia Univ. Catolica de Sao Paulo, SP (Brazil); Instituto de Pesquisas Energeticas e Nucleares IPEN/CNEN-SP, Sao Paulo, SP (Brazil)]. E-mail: corain.lopes@uol.com.br; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: jaosso@ipen.br

    2007-07-01

    Over the last years {sup 99m}Tc has become a very important asset in modern nuclear medicine, due to the emission of gamma ray of optimal energy (140 keV) and a suitable half-life (6.04 h). A further attribute of {sup 99m}Tc is its formation from the decay of {sup 99}Mo and the availability from {sup 99}Mo-{sup 99m}Tc generator systems. The most common and practical generator types consist of a chromatographic column packed with aluminium oxide, onto which the highly purified fission product {sup 99}Mo (imported from Canada) is adsorbed in the form of molybdate. {sup 99m}Tc is further eluted with saline solution. The objective of this work is to study the performance and the elution profile of {sup 99m}Tc from high activity generators in order to decrease molybdenum and aluminium concentration. The experiments involved the use of paper filters and Sep Pak columns and also the changing in the time interval between elutions. {sup 99}Mo breakthrough was measured using a dose calibrator and aluminium by UV-Vis spectrophotometry. The best results were achieved using a Sep Pak column containing neutral aluminium oxide. (author)

  6. Strontium eluting graphene hybrid nanoparticles augment osteogenesis in a 3D tissue scaffold

    Science.gov (United States)

    Kumar, Sachin; Chatterjee, Kaushik

    2015-01-01

    The objective of this work was to prepare hybrid nanoparticles of graphene sheets decorated with strontium metallic nanoparticles and demonstrate their advantages in bone tissue engineering. Strontium-decorated reduced graphene oxide (RGO_Sr) hybrid nanoparticles were synthesized by the facile reduction of graphene oxide and strontium nitrate. X-ray diffraction, transmission electron microscopy, and atomic force microscopy revealed that the hybrid particles were composed of RGO sheets decorated with 200-300 nm metallic strontium particles. Thermal gravimetric analysis further confirmed the composition of the hybrid particles as 22 wt% of strontium. Macroporous tissue scaffolds were prepared by incorporating RGO_Sr particles in poly(ε-caprolactone) (PCL). The PCL/RGO_Sr scaffolds were found to elute strontium ions in aqueous medium. Osteoblast proliferation and differentiation was significantly higher in the PCL scaffolds containing the RGO_Sr particles in contrast to neat PCL and PCL/RGO scaffolds. The increased biological activity can be attributed to the release of strontium ions from the hybrid nanoparticles. This study demonstrates that composites prepared using hybrid nanoparticles that elute strontium ions can be used to prepare multifunctional scaffolds with good mechanical and osteoinductive properties. These findings have important implications for designing the next generation of biomaterials for use in tissue regeneration.The objective of this work was to prepare hybrid nanoparticles of graphene sheets decorated with strontium metallic nanoparticles and demonstrate their advantages in bone tissue engineering. Strontium-decorated reduced graphene oxide (RGO_Sr) hybrid nanoparticles were synthesized by the facile reduction of graphene oxide and strontium nitrate. X-ray diffraction, transmission electron microscopy, and atomic force microscopy revealed that the hybrid particles were composed of RGO sheets decorated with 200-300 nm metallic strontium

  7. Radiosensitive xrs-5 and parental CHO cells show identical DNA neutral filter elution dose-response: implications for a relationship between cell radiosensitivity and induction of DNA double-strand breaks

    International Nuclear Information System (INIS)

    Iliakis, George; Okayasu, Ryuichi; Seaner, Robert

    1988-01-01

    The purpose of this work was to investigate a possible correlation between DNA elution dose-response and cell radiosensitivity. For this purpose neutral (pH 9.6) DNA filter elution dose-response curves were measured with radiosensitive xrs-5 and the parental Chinese hamster ovary (CHO) cells in the logarithmic and plateau phase of growth. No difference was observed between the two cell types in the DNA elution dose-response curves either in logarithmic or plateau phase, despite the dramatic differences in cell radiosensitivity. This observation indicates that the shape of the DNA elution dose-response curve and the shape of the cell survival curve are not causally related. It is proposed that the shoulder observed in the DNA elution dose-response curve reflects either partial release of DNA from chromatin, or cell cycle-specific alterations in the physicochemical properties of the DNA. (author)

  8. Studies on DNA damage: discordant responses of rate of DNA disentanglement (viscosimetrically evaluated) and alkaline elution rate, obtained for several compounds. Possible explanations of the discrepancies.

    Science.gov (United States)

    Parodi, S; Balbi, C; Abelmoschi, M L; Pala, M; Russo, P; Santi, L

    1983-12-01

    Alkaline elution is a well-known method for detecting DNA damage. Recently we have developed a viscosimetric method that is even more sensitive than alkaline elution. Here we report that the two methods, although apparently both revealing alkaline DNA fragmentation, can give dramatically different results for a significant series of compounds. We suspect that alkaline elution might reveal not only DNA fragmentation but also the extent of disentanglement of chromatin structure, whereas this DNA disentanglement rate, when evaluated viscosimetrically , is more strictly correlated with the initiation of DNA unwinding.

  9. Drug eluting stents and modern stent technologies for in-stent restenosis.

    Science.gov (United States)

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  10. A randomized, controlled, multicenter trial to evaluate the safety and efficacy of Zotarolimus- vs. Paclitaxel-eluting stents in de novo occlusive lesions in coronary arteries

    DEFF Research Database (Denmark)

    Chevalier, Bernard; Dimario, Carlo; Neumann, Franz-Josef

    2013-01-01

    The ZOMAXX I trial tested the noninferiority of a zotarolimus-eluting coronary stent (ZoMaxx(™) ) when compared with a paclitaxel-eluting coronary stent (Taxus(™) Express(2™) ) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. Angiographic analysis at the pr...

  11. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.

    Science.gov (United States)

    Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko

    2015-11-01

    The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Recent developments in drug eluting devices with tailored interfacial properties.

    Science.gov (United States)

    Sanchez-Rexach, Eva; Meaurio, Emilio; Sarasua, Jose-Ramon

    2017-11-01

    Drug eluting devices have greatly evolved during past years to become fundamental products of great marketing importance in the biomedical field. There is currently a large diversity of highly specialized devices for specific applications, making the development of these devices an exciting field of research. The replacement of the former bare metal devices by devices loaded with drugs allowed the sustained and controlled release of drugs, to achieve the desired local therapeutic concentration of drug. The newer devices have been "engineered" with surfaces containing micro- and nanoscale features in a well-controlled manner, that have shown to significantly affect cellular and subcellular function of various biological systems. For example, the topography can be structured to form an antifouling surface mimicking the defense mechanisms found in nature, like the skin of the shark. In the case of bone implants, well-controlled nanostructured interfaces can promote osteoblast differentiation and matrix production, and enhance short-term and long-term osteointegration. In any case, the goal of current research is to design implants that induce controlled, guided, and rapid healing. This article reviews recent trends in the development of drug eluting devices, as well as recent developments on the micro/nanotechnology scales, and their future challenges. For this purpose medical devices have been divided according to the different systems of the body they are focused to: orthopedic devices, breathing stents, gastrointestinal and urinary systems, devices for cardiovascular diseases, neuronal implants, and wound dressings. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Adding functionality with additive manufacturing: Fabrication of titanium-based antibiotic eluting implants.

    Science.gov (United States)

    Cox, Sophie C; Jamshidi, Parastoo; Eisenstein, Neil M; Webber, Mark A; Hassanin, Hany; Attallah, Moataz M; Shepherd, Duncan E T; Addison, Owen; Grover, Liam M

    2016-07-01

    Additive manufacturing technologies have been utilised in healthcare to create patient-specific implants. This study demonstrates the potential to add new implant functionality by further exploiting the design flexibility of these technologies. Selective laser melting was used to manufacture titanium-based (Ti-6Al-4V) implants containing a reservoir. Pore channels, connecting the implant surface to the reservoir, were incorporated to facilitate antibiotic delivery. An injectable brushite, calcium phosphate cement, was formulated as a carrier vehicle for gentamicin. Incorporation of the antibiotic significantly (p=0.01) improved the compressive strength (5.8±0.7MPa) of the cement compared to non-antibiotic samples. The controlled release of gentamicin sulphate from the calcium phosphate cement injected into the implant reservoir was demonstrated in short term elution studies using ultraviolet-visible spectroscopy. Orientation of the implant pore channels were shown, using micro-computed tomography, to impact design reproducibility and the back-pressure generated during cement injection which ultimately altered porosity. The amount of antibiotic released from all implant designs over a 6hour period (additively manufacture a titanium-based antibiotic eluting implant, which is an attractive alternative to current treatment strategies of periprosthetic infections. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Application of rotational atherectomy in the drug-eluting stent era

    Science.gov (United States)

    Chen, Chun-Chi; Hsieh, I-Chang

    2013-01-01

    Rotational atherectomy (RA) was introduced in the interventional arena in 1988 as a dedicated device for calcified lesions. Due to the complexity of the technique, the development of alternative methods such as the cutting balloon procedure, and the high restenosis rate of subsequent bare metal stenting in long lesions, its use had later declined. However, with the increasing use of drug-eluting stents (DES) and the aggressive treatment of longer lesions, the number of procedure performed with RA has increased significantly again in recent years. In this article, we reviewed the application of RA in DES era. PMID:24133506

  15. Alkaline elution of uranium and molybdenum and their recovery

    International Nuclear Information System (INIS)

    Song Wenlan; Wu Peisheng; Zhao Pinzhi; Tao Dening; Xie Chaoyan

    1987-01-01

    The uranium and molybdenum can be simultaneously eluted by using eluant (NH 4 ) 2 CO 3 + (NH 4 ) 2 SO 4 from resin loaded uranium and molybdenum. The ADU is precipitated from eluant by volatilization of ammonia. The molybdenum is extracted by TFA-TBP-kerosene from the filtrate at pH 3.0-3.2 with molybdenum extraction > 98%. Uranium is nearly not extracted. The precipitation of Mo is reached by sulphuric acid after stripping and the ammonium multimolybdate is obtained. This process can give the total recovery more than 99% for U and 90% for Mo. Because of the use of sulphate salt system, the hazard of NO 3 - can be avoided

  16. Comparison of clinical outcomes after drug-eluting balloon and drug-eluting stent use for in-stent restenosis related acute myocardial infarction: a retrospective study

    Directory of Open Access Journals (Sweden)

    Chih-Yuan Fang

    2018-04-01

    Full Text Available Background Good results of drug-eluting balloon (DEB use are achieved in in-stent restenosis (ISR lesions, small vessel disease, long lesions, and bifurcations. However, few reports exist about DEB use in acute myocardial infarction (AMI with ISR. This study’s aim was to evaluate the efficacy of DEB for AMI with ISR. Methods Between November 2011 and December 2015, 117 consecutive patients experienced AMI including ST-segment elevation MI, and non-ST-segment elevation MI due to ISR, and received percutaneous coronary intervention (PCI. We divided our patients into two groups: (1 PCI with further DEB, and (2 PCI with further drug-eluting stent (DES. Clinical outcomes such as target lesion revascularization, target vessel revascularization, recurrent MI, stroke, cardiovascular mortality, and all-cause mortality were analyzed. Results The patients’ average age was 68.37 ± 11.41 years; 69.2% were male. A total of 75 patients were enrolled in the DEB group, and 42 patients were enrolled in the DES group. The baseline characteristics between the two groups were the same without statistical differences except for gender. Peak levels of cardiac biomarker, pre- and post-PCI cardiac function were similar between two groups. The major adverse cardiac cerebral events rate (34.0% vs. 35.7%; p = 0.688 and cardiovascular mortality rate (11.7% vs. 12.8%; p = 1.000 were similar in both groups. Conclusions DEB is a reasonable strategy for AMI with ISR. Compared with DES, DEB is an alternative strategy which yielded acceptable short-term outcomes and similar 1-year clinical outcomes.

  17. The role of drug-eluting balloons alone or in combination with drug-eluting stents in the treatment of de novo diffuse coronary disease.

    Science.gov (United States)

    Costopoulos, Charis; Latib, Azeem; Naganuma, Toru; Sticchi, Alessandro; Figini, Filippo; Basavarajaiah, Sandeep; Carlino, Mauro; Chieffo, Alaide; Montorfano, Matteo; Naim, Charbel; Kawaguchi, Masanori; Giannini, Francesco; Colombo, Antonio

    2013-11-01

    This study sought to investigate the role of drug-eluting balloons (DEB) alone or in combination with drug-eluting stents (DES) in the treatment of diffuse de novo coronary artery disease (CAD) (>25 mm). The use of DEB in diffuse CAD, either alone or in combination with DES, offers an alternative to stenting alone. Data regarding DEB in this context are limited. We retrospectively evaluated all patients treated with DEB for diffuse CAD between June 2009 and October 2012. Endpoints analyzed were major adverse cardiac events, defined as all-cause death, myocardial infarction, and target vessel revascularization (TVR), as well as TVR and target lesion revascularization separately. Results were compared with those obtained from a cohort of patients with similar characteristics treated with DES alone. A total of 69 patients (93 lesions) were treated with DEB ± DES, and 93 patients with DES alone (93 lesions). A high proportion of patients were diabetic (46.4% vs. 44.1%, p = 0.77). Of the DEB-treated lesions, 56.0% were treated with DEB alone, 7.4% with DEB and DES as bail out, and 36.6% with DES and DEB as part of a hybrid approach for very long disease. Outcome rates with DEB ± DES were comparable to those with DES alone at 2-year follow-up (major adverse cardiac events = 20.8% vs. 22.7%, p = 0.74; TVR = 14.8% vs. 11.5%, p = 0.44; target lesion revascularization = 9.6% vs. 9.3%, p = 0.84). DEB may have a role in the treatment of diffuse de novo CAD, either alone in smaller vessels or in combination with DES in very long disease. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Comparison of elution efficiency of 99Mo/99mTc generator using theoretical and a free web based software method

    International Nuclear Information System (INIS)

    Kiran Kumar, J.K.; Sharma, S.; Chakraborty, D.; Singh, B.; Bhattacharaya, A.; Mittal, B.R.; Gayana, S.

    2010-01-01

    Full text: Generator is constructed on the principle of decay growth relationship between a long lived parent radionuclide and short lived daughter radionuclide. Difference in chemical properties of daughter and parent radionuclide helps in efficient separation of the two radionuclides. Aim and Objectives: The present study was designed to calculate the elution efficiency of the generator using the traditional formula based method and free web based software method. Materials and Methods: 99 Mo/ 99m Tc MON.TEK (Monrol, Gebze) generator and sterile 0.9% NaCl vial and vacuum vial in the lead shield were used for the elution. A new 99 Mo/ 99m Tc generator (calibrated activity 30GBq) calibrated for thursday was received on monday morning in our department. Generator was placed behind lead bricks in fume hood. The rubber plugs of both vacuum and 0.9% NaCl vial were wiped with 70% isopropyl alcohol swabs. Vacuum vial placed inside the lead shield was inserted in the vacuum position simultaneously 10 ml NaCl vial was inserted in the second slot. After 1-2 min vacuum vial was removed without moving the emptied 0.9%NaCl vial. The vacuum slot was covered with another sterile vial to maintain sterility. The RAC was measured in the calibrated dose calibrator (Capintec, 15 CRC). The elution efficiency was calculated theoretically and using free web based software (Apache Web server (www.apache.org) and PHP (www.php.net). Web site of the Italian Association of Nuclear Medicine and Molecular Imaging (www.aimn.it). Results: The mean elution efficiency calculated by theoretical method was 93.95% +0.61. The mean elution efficiency as calculated by the software was 92.85% + 0.89. There was no statistical difference in both the methods. Conclusion: The free web based software provides precise and reproducible results and thus saves time and mathematical calculation steps. This enables a rational use of available activity and also enabling a selection of the type and number of

  19. Neutron activation analysis of trace metallic elements eluted from molecular sieves in the dehydration process of safflower oil

    International Nuclear Information System (INIS)

    Takasago, Masahisa; Kobayashi, Koichi; Taru, Yasunori; Takaoka, Kyo

    1992-01-01

    Dissolved water in safflower oil affects the autoxidation of this oil significantly. Molecular sieves were used to remove the dissolved water from the oil. This method is much simpler than that of distillation, and dissolved water can be removed to the same extent as that by distillation. But, due to the elution of many kinds of trace metallic elements in the oil dehydrated with molecular sieves, these elements were analyzed by neutron activation analysis. For a data comparison trace amounts of metallic elements in the oil dehydrated by distillation were also analyzed. Since the intensity of the γ ray-photoelectric peak of nuclide 28 Al was largest among the detected elements, this element was analyzed quantitatively and the other elements qualitatively. In safflower oil dehydrated with molecular sieves, 14 kinds of the elements (I, Br, Al, Mg, Si, V, Cl, Nd, Ta, Cr, Sb, Cs, Co, Na) were detected. Also, I, Br, Cl, Cr, Ta, Sb, and Al elements were detected in the oil dehydrated by distillation. The intensity of the photoelectric peak of nuclide except 28 Al was essentially the same as that in the oil dehydrated by distillation, but the intensity of 28 Al in the oil with molecular sieves was about 28 times stronger than that in distillation oil. In the molecular sieves, 19 impure elements in addition to the original constituents (Na, K, Al, si, O) were detected. It was Al, Na, Si, Nd, Cs, and Co along with impure elements may possibly have been eluted in the oil. Al element in safflower oil dehydrated with molecular sieves was analyzed quantitatively. 0.91 ppm of Al was detected in safflower oil. The eluted amount of Al in safflower oil dehydrated by distillation was 0.032 ppm. A larger amount of Al element was thus eluted into the oil dehydrated with molecular sieves than by distillation. (author)

  20. Antibiotic eluting clay mineral (Laponite®) for wound healing application: an in vitro study.

    Science.gov (United States)

    Ghadiri, M; Chrzanowski, W; Rohanizadeh, R

    2014-11-01

    Different materials in form of sponge, hydrogel and film have been developed and formulated for treating and dressing burn wounds. In this study, the potential of Laponite, a gel forming clay, in combination with an antimicrobial agent (mafenide), as a wound dressing material was tested in vitro. Laponite/mafenide (Lap/Maf) hydrogel was formulated in three different ratios of Lap/Maf 1:1, 1:2, 1:3. Laponite/mafenide/alginate (Lap/Maf/Alg) film was also formulated by combining Lap/Maf gel (1:1) with alginate. Intercalation rate of mafenide into the layers of Laponite nanoparticles and physico-chemical properties, including wound dressing characteristics of materials were studied using various analytical methods. Furthermore, the degradation of materials and the release profile of mafenide were investigated in simulated wound exudates fluid and antibacterial effectiveness of the eluted mafenide was tested on a range of bacterial species. The cytotoxicity of materials was also evaluated in skin fibroblast culture. The results showed that mafenide molecules were intercalated between the nano-sized layers of Laponite. The eluted mafenide showed active antibacterial effects against all three tested bacteria. All intercalated mafenide released from Lap/Maf 1:1 and 1:2 gel formulations and nearly 80% release from 1:3 formulation during test period. No significant difference was observed in release profile of mafenide between Lap/Maf/Alg film and Lap/Maf formulations. Wound dressing tests on Lap/Maf/Alg film showed it is a breathable dressing and has capacity to absorb wound exudates. The study showed that prepared Lap/Maf composite has the potential to be used as an antibiotic eluting gel or film for wound healing application. Additionally, Laponite has shown benefits in wound healing processes by releasing Mg(2+) ions and thereby reducing the cytotoxic effect of mafenide on fibroblast cells.

  1. Development of a sirolimus-eluting poly (L-lactide)/poly(4-hydroxybutyrate) absorbable stent for peripheral vascular intervention.

    Science.gov (United States)

    Grabow, Niels; Bünger, Carsten M; Kischkel, Sabine; Timmermann, J Hinrich; Reske, Thomas; Martin, David P; Williams, Simon F; Schareck, Wolfgang; Sternberg, Katrin; Schmitz, Klaus-Peter

    2013-10-01

    Fully absorbable drug-eluting stent platforms are currently entering the clinical arena for the interventional treatment of coronary artery disease. This new technology also holds potential for application in peripheral vascular settings. Our study reports on the development of a sirolimus- (SIR) eluting absorbable polymer stent made from a blend of poly(l-lactide) and poly(4-hydroxybutyrate) (PLLA/P4HB) for peripheral vascular intervention. Stent prototypes were laser-cut from PLLA/P4HB tubes (I.D.=2.2 mm, t=250 µm), spray-coated with different PLLA/P4HB/SIR solutions, and bench-tested to determine expansion properties, fatigue, trackability and in vitro drug release kinetics. The stent prototypes were expanded with a 5.0 × 20 mm balloon catheter, and exhibited a recoil of 3.6% upon balloon deflation. Stent collapse pressure of 0.4 bar (300 mm Hg) was measured under external pressure load. Sustained scaffolding properties were observed in vitro over 14 weeks of radial fatigue loading (50 ± 25 mm Hg at 1.2 Hz). Trackability was demonstrated in bench tests with an 8 French contralateral introducer sheath. SIR release kinetics were adjusted over a broad range by varying the PLLA/P4HB ratio of the coating matrix. The newly developed absorbable SIR-eluting PLLA/P4HB stent successfully fulfilled the requirements for peripheral vascular intervention under in vitro conditions.

  2. EW-7197 eluting nano-fiber covered self-expandable metallic stent to prevent granulation tissue formation in a canine urethral model.

    Directory of Open Access Journals (Sweden)

    Kichang Han

    Full Text Available To evaluate an EW-7197-eluting nanofiber-covered stent (NFCS for suppressing granulation tissue formation after stent placement in a canine urethral model.All experiments were approved by the committee of animal research. A total of 12 NFCSs were placed in the proximal and distal urethras of six dogs. Dogs were divided into two groups with 3 dogs each. The control stent (CS group received NFCSs and the drug stent (DS group received EW-7197 (1000 μg-eluting NFCSs. All dogs were sacrificed 8 weeks after stent placement Histologic findings of the stented urethra were compared using the Mann-Whitney U test.Stent placement was technically successful in all dogs without procedure-related complications. On urethrographic analysis, the mean luminal diameter was significantly larger in the DS group than in the CS group at 4 and 8 weeks after stent placement (all p 0.05.The EW-7197-eluting NFCS is effective and safe for suppressing granulation tissue formation after stent placement in a canine urethral model.

  3. The indicating FTA elute cartridge a solid sample carrier to detect high-risk HPV and high-grade cervical lesions.

    Science.gov (United States)

    de Bie, Roosmarie P; Schmeink, Channa E; Bakkers, Judith M J E; Snijders, Peter J F; Quint, Wim G V; Massuger, Leon F A G; Bekkers, Ruud L M; Melchers, Willem J G

    2011-07-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were compared with liquid-based samples for hrHPV and high-grade cervical intraepithelial neoplasia (CIN) detection. One cervical sample was collected in a liquid-based medium, and one was applied to the FTA cartridge. DNA was eluted directly from the FTA cartridge by a simple elution step. HC2 and GP5+/6+-PCR assays were performed on both the liquid-based and the FTA-eluted DNA of 88 women. Overall agreement between FTA and liquid-based samples for the presence of hrHPV was 90.9% with GP5+/6+-PCR and 77.3% with HC2. The sensitivity for high-grade CIN of hrHPV testing on the FTA cartridges was 84.6% with GP5+/6+-PCR and only 53.8% with HC2. By comparison, these sensitivities on liquid-based samples were 92.3% and 100% for GP5+/6+-PCR and HC2, respectively. Therefore, the FTA cartridge shows reasonably good overall agreement for hrHPV detection with liquid-based media when using GP5+/6+-PCR but not HC2 testing. Even with GP5+/6+-PCR, the FTA cartridge is not yet capable of detecting all high-grade CIN lesions. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  4. Safety and efficacy of everolimus-eluting stents for bare-metal in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Torguson, Rebecca; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-04-15

    Objective: The aim of this study was to compare the safety and efficacy of the everolimus-eluting stents (EES) with the paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) for the treatment of bare-metal in-stent restenosis. Background: The optimal treatment for bare-metal in-stent restenosis remains controversial. Methods: The study cohort comprised 322 consecutive patients (543 lesions) who presented with bare-metal in-stent restenosis to our institution and underwent coronary artery stent implantation with EES (114 patients; 181 lesions), PES (65 patients; 116 lesions) and SES (143 patients; 246 lesions). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac events (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors except for age and chronic kidney disease. The 1-year analyzed clinical parameters were similar in the three groups: death (EES = 3.5%, PES = 4.6%, SES = 4.2%; p = 0.94), MI (EES = 3.5%, PES = 6.3%, SES = 2.1%; p = 0.31), TLR (EES = 9.8%, PES = 9.5%, SES = 5.7%; p = 0.42), TVR (EES = 14.3%, PES = 11.1%, SES = 11.3%; p = 0.74), definite ST (EES = 0.9%, PES = 3.1%, SES = 3.5%; p = 0.38) and MACE (EES = 14.0%, PES = 15.4%, SES = 10.5%; p = 0.54). Male gender (hazard ratio = 0.47; 95% confidence interval = 0.25–0.88) and number of treated lesions (hazard ratio = 1.47; 95% confidence interval = 1.06–2.05) were found to be independent predictors of MACE. Conclusion: The results of the present study indicate that EES may provide similar safety and efficacy as first generation DES for the treatment of patients presenting with bare-metal in-stent restenosis.

  5. The Promus Premier everolimus-eluting platinum chromium stent with durable polymer evaluated in a real world all-comer population in Rotterdam cardiology hospital (the P-SEARCH registry)

    NARCIS (Netherlands)

    Lemmert, M.E.; Mieghem, N.M. van; Geuns, R.J.M. van; Diletti, R.; Bommel, R.J. van; Domburg, R.T. van; Jaegere, P.P. de; Regar, E.; Zijlstra, F.; Boersma, E.; Daemen, J.

    2017-01-01

    BACKGROUND: A new-generation everolimus eluting platinum-chromium stent (EePCS), offering improved radial strength, radiopacity and conformability compared to everolimus-eluting cobalt-chromium stents (EeCCS), was evaluated with regard to safety and efficacy in an all-comer cohort. METHODS: A total

  6. Long-term clinical outcome in STEMI patients treated with primary PCI and drug-eluting or bare-metal stents: insights from a high-volume single-center registry

    DEFF Research Database (Denmark)

    Pedersen, Sune; Galatius, Soren; Mogelvang, Rasmus

    2011-01-01

    Use of drug-eluting stents (DES) in patients with ST-elevation myocardial infarction (STEMI) during routine primary percutaneous coronary intervention (pPCI) is controversial.......Use of drug-eluting stents (DES) in patients with ST-elevation myocardial infarction (STEMI) during routine primary percutaneous coronary intervention (pPCI) is controversial....

  7. Drug-eluting stents versus bare-metal stents for acute coronary syndrome

    DEFF Research Database (Denmark)

    Feinberg, Joshua; Nielsen, Emil Eik; Greenhalgh, Janette

    2017-01-01

    -EXPANDED, and BIOSIS from their inception to January 2017. We also searched two clinical trials registers, the European Medicines Agency and the US Food and Drug Administration databases, and pharmaceutical company websites. In addition, we searched the reference lists of review articles and relevant trials. SELECTION...... CRITERIA: Randomised clinical trials assessing the effects of drug-eluting stents versus bare-metal stents for acute coronary syndrome. We included trials irrespective of publication type, status, date, or language. DATA COLLECTION AND ANALYSIS: We followed our published protocol and the methodological...

  8. Influence of elution rate on the efficiency of chromatographic separation process of rare earth and transplutonium elements

    International Nuclear Information System (INIS)

    Peshkov, A.S.; Chuveleva, Eh.A.; Nazarov, P.P.; Rybakov, S.Yu.

    1990-01-01

    Applicability of finely dispersed sulfocationites of the KU-2-8 MD grade for the separation of radionuclides of rare earth and transplutonium element separation by the method of replacing complexing chromatography (RCC) has been investigated. Using as an example separation of neodymium-praseodymium, yttrium-europium by the RCC method, using nitriloacetic (1) and diethylenetriaminepentaacetic (2) acid solutions as eluent, the dependence of the element separation of ficiency on elution rate is shown. It is found that when using solution 1 as eluent, the value of the height equivalent to theoretical plate depends on elution rate much less, than in case of solution 2. The conclusion is made that for 1 the main contribution to the blurring of the areas is made by transcolumn effect, and for 2 -by transcolumn and transpartial effects

  9. First-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial.

    Science.gov (United States)

    von Birgelen, Clemens; Asano, Taku; Amoroso, Giovanni; Aminian, Adel; Brugaletta, Salvatore; Vrolix, Mathias; Hernandez-Antolín, Rosana; van de Harst, Pim; Iñiguez, Andres; Janssens, Luc; Smits, Pieter C; Wykrzykowska, Joanna J; Ribeiro, Vasco Gama; Pereira, Hélder; da Silva, Pedro Canas; Piek, Jan J; Onuma, Yoshinobu; Serruys, Patrick W; Sabaté, Manel

    2018-04-20

    A second iteration of a sirolimus-eluting stent (SES) that has a biodegradable PLGA polymer coating with an electrografting base layer on a thin-strut (80 µm) cobalt-chromium platform (BuMA Supreme; SINOMED, Tianjin, China) has been developed. This first-in-man trial aimed to assess the efficacy and safety of the novel device. This randomised, multicentre, single-blinded, non-inferiority trial compared the BuMA Supreme SES versus a contemporary durable polymer zotarolimus-eluting stent (ZES) in terms of angiographic in-stent late lumen loss (LLL) at nine-month follow-up as the primary endpoint. A total of 170 patients were randomly allocated to treatment with either SES (n=83) or ZES (n=87). At nine-month angiographic follow-up, in-stent LLL was 0.29±0.33 mm in the SES group and 0.14±0.37 mm in the ZES group (pnon-inferiority=0.45). The in-stent percent diameter stenosis and the binary restenosis rate of the two treatment arms were similar (19.2±12.0% vs. 16.1±12.6%, p=0.09, and 3.3% vs. 4.4%, p=1.00, respectively). At 12-month clinical follow-up, there was no difference between treatment arms with regard to the device-oriented composite clinical endpoint (4.9% vs. 5.7%; p=0.72). The PIONEER trial did not meet its primary endpoint in terms of in-stent LLL at nine-month follow-up. However, this result did not translate into any increase in restenosis rate or impairment in 12-month clinical outcomes.

  10. Quantitation of radiolabeled compounds eluting from the HPLC system

    International Nuclear Information System (INIS)

    Kessler, M.J.

    1982-01-01

    Three techniques are compared for the quantitation of various radiolabeled compounds eluting in the high performance liquid chromatography system. The first technique requires fraction-collecting the effluent from the HPLC, removing an aliquot to scintillation vials, and counting each fraction in a liquid scintillation counter. The second uses direct interface of the HPLC effluent to a flow-through radioactivity detector. The third involves quantitation of various radiolabeled compounds (proteins, steroids, and nucleotides) by splitting the effluent from the HPLC with an electronic steam splitter, thus diverting a present portion to the fraction collector for further chemical characterization and the remainder to the radioactivity flow detector for direct quantitation. A direct comparison of the chromatograms and the radioactivity counting efficiencies of these three techniques is presented

  11. The OCT-ORION Study: A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-Eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss.

    Science.gov (United States)

    Lee, Stephen W L; Tam, Frankie C C; Lam, Simon C C; Kong, Shun-Ling; Shea, Catherine P; Chan, Kelvin K W; Wong, Michael K L; Chan, Michael P H; Wong, Anthony Y T; Yung, Arthur S Y; Lam, Yui-Ming; Zhang, Lei-Wei; Wu, Karl K Y; Mintz, Gary S; Maehara, Akiko

    2018-04-01

    Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer. Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months ( P <0.001) and less variance of percent coverage at 9 months, 99.7% (interquartile range, 99.1-100) versus 99.6% (interquartile range, 96.8-99.9; difference, 0.10; 95% confidence interval, 0.00-1.05; P <0.001). No significant difference was observed in major adverse cardiac events or angiographic end points. Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small

  12. Retention prediction and separation optimization under multilinear gradient elution in liquid chromatography with Microsoft Excel macros.

    Science.gov (United States)

    Fasoula, S; Zisi, Ch; Gika, H; Pappa-Louisi, A; Nikitas, P

    2015-05-22

    A package of Excel VBA macros have been developed for modeling multilinear gradient retention data obtained in single or double gradient elution mode by changing organic modifier(s) content and/or eluent pH. For this purpose, ten chromatographic models were used and four methods were adopted for their application. The methods were based on (a) the analytical expression of the retention time, provided that this expression is available, (b) the retention times estimated using the Nikitas-Pappa approach, (c) the stepwise approximation, and (d) a simple numerical approximation involving the trapezoid rule for integration of the fundamental equation for gradient elution. For all these methods, Excel VBA macros have been written and implemented using two different platforms; the fitting and the optimization platform. The fitting platform calculates not only the adjustable parameters of the chromatographic models, but also the significance of these parameters and furthermore predicts the analyte elution times. The optimization platform determines the gradient conditions that lead to the optimum separation of a mixture of analytes by using the Solver evolutionary mode, provided that proper constraints are set in order to obtain the optimum gradient profile in the minimum gradient time. The performance of the two platforms was tested using experimental and artificial data. It was found that using the proposed spreadsheets, fitting, prediction, and optimization can be performed easily and effectively under all conditions. Overall, the best performance is exhibited by the analytical and Nikitas-Pappa's methods, although the former cannot be used under all circumstances. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Outcome of Sirolimus-Eluting Versus Zotarolimus-Eluting Coronary Stent Implantation in Patients With and Without Diabetes Mellitus (a SORT OUT III Substudy)

    DEFF Research Database (Denmark)

    Maeng, Michael; Jensen, Lisette O; Tilsted, Hans-Henrik

    2011-01-01

    Diabetes is associated with an increased risk of major adverse cardiac events after percutaneous coronary intervention. We compared clinical outcomes in patients with and without diabetes mellitus treated with the second-generation Endeavor zotarolimus-eluting stent (ZES) or the first...... cardiac events defined as a composite of cardiac death, myocardial infarction, or target vessel revascularization. Secondary end points included these individual end points plus all-cause mortality and target lesion revascularization. In diabetic patients, use of ZES compared to SES was associated.......90 to 13.1), and target lesion revascularization (12.4% vs 1.2%, hazard ratio 11.0, 95% confidence interval 2.59 to 47.1). In patients without diabetes differences in absolute risk decrease were smaller but similarly favored SES. In conclusion, implantation of ZESs compared to SESs is associated...

  14. Correlating cytotoxicity to elution behaviors of composite resins in term of curing kinetic.

    Science.gov (United States)

    Meng, Junquan; Yang, Huichuan; Cao, Man; Li, Lei; Cai, Qing

    2017-09-01

    Cytotoxicity of photocurable composite resins is a key issue for their safe use in dental restoration. Curing kinetic and elution behaviors of the composite resin would have decisive effects on its cytotoxicity. In this study, composite resins composed of bisphenol-glycidyl dimethacrylate (Bis-GMA), triethyleneglycol dimethacrylate (TEGDMA), camphorquinone (CQ), N,N-dimethylaminoethyl methacrylate (DMAEMA) and barium glass powders were prepared by setting the photoinitiators CQ/DMAEMA at 0.5wt%, 1wt% or 3wt% of the total weight of Bis-GMA/TEGDMA. The ratio of Bis-GMA/TEGDMA was 6:4, the ratio of CQ/DMAEMA was 1:1, and the incorporated inorganic powder was 75wt%. Then, curing kinetics were studied by using real-time Fourier transform infrared spectroscopy (FTIR) and photo-DSC (differential scanning calorimeter). Elution behaviors in both ethanol solution and deionized water were monitored by using liquid chromatogram/mass spectrometry (LC/MS). Cytotoxicity was evaluated by in vitro culture of L929 fibroblasts. Finally, they were all analyzed and correlated in terms of initiator contents. It was found that the commonly used 0.5wt% of photoinitiators was somewhat insufficient in obtaining composite resin with low cytotoxicity. Copyright © 2017. Published by Elsevier B.V.

  15. Liquid chromatography tandem mass spectrometry determination of total budesonide levels in dog plasma after inhalation exposure.

    Science.gov (United States)

    Berg, Seija; Melamies, Marika; Rajamäki, Minna; Vainio, Outi; Peltonen, Kimmo

    2012-01-01

    A sensitive and selective method to quantify budesonide in dog plasma samples was developed and fully validated. Liquid-liquid extraction was followed by solid-phase extraction and liquid chromatography-tandem mass spectrometry with electrospray ionization. After reconstitution of the analytes in the mobile phase, samples were analysed by reversed-phase liquid chromatography with isocratic elution. d8-Budesonide was used as an internal standard, and characteristic transitions of d8-budesonide and budesonide were used for quantification. The method was validated with respect to selectivity, specificity, linearity, recovery, repeatability, reproducibility and limits of detection and quantification. The validated method was successfully applied to monitor the plasma levels of budesonide in dogs exposed to clinical doses of inhaled and intravenous drug.

  16. Elution-extrusion counter-current chromatography for the separation of two pairs of isomeric monoterpenes from Paeoniae Alba Radix.

    Science.gov (United States)

    Chu, Chu; Zhang, Shidi; Tong, Shengqiang; Li, Xingnuo; Li, Qingyong; Yan, Jizhong

    2015-09-01

    In this work, a simple and efficient protocol for the rapid separation of two pairs of isomeric monoterpenes from Paeoniae Alba Radix was developed by combining macroporous resin and elution-extrusion counter-current chromatography. The crude extract was firstly subjected to a D101 macroporous resin column eluted with water and a series of different concentrations of ethanol. Then, effluents of 30 and 95% ethanol were collected as sample 1 and sample 2 for further counter-current chromatography purification. Finally, a pair of isomers, 96 mg of compound 1 and 48 mg of compound 2 with purities of 91.1 and 96.2%, respectively, was isolated from 200 mg of sample 1. The other pair of isomers, 14 mg of compound 3 and 8 mg of compound 4 with purities of 93.6 and 88.9%, respectively, was isolated from 48 mg of sample 2. Their purities were analyzed by high-performance liquid chromatography, and their chemical structures were identified by mass spectrometry and (1) H NMR spectroscopy. Compared to a normal counter-current chromatography separation, the separation time and solvent consumption of elution-extrusion counter-current chromatography were reduced while the resolutions were still good. The established protocol is promising for the separation of natural products with great disparity of content in herbal medicines. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Preparation and characterization of iron(III) 99Mo-molybdate(VI) gels for the assessment of 99mTc elution performance

    International Nuclear Information System (INIS)

    Amin, Mahmoud; Fasih, Tharwat W.; El-Absy, Mohamed A.

    2018-01-01

    New iron(III) 99 Mo-molybdate(VI) gels (Fe 99 Mo) of high Mo content were prepared by the precipitation/filtration method. 99 Mo-MoO 3 dissolved in NaOH was added to aqueous solutions of Fe(NO 3 ) 3 at Mo/Fe mole fractions ∝2.21 and 1.99 with continuous stirring at ambient room temperature. Two different Fe 99 Mo were precipitated from the mixed solutions adjusted at pH 2 and 4.7. The amount of water of hydration increased with the increasing the gel settling time and pH of the mixed solution. The matrices were characterized by radiometric, XRD, SEM, XRF, FT-IR, TGA, and DTA measurements. Small chromatographic columns of 2.0 g Fe 99 Mo containing ≥800 mg Mo tagged with 740 MBq 99 Mo were eluted with 5 mL saline solution. Highly reproducible 99m Tc elution indices suitable for preparation of 99 Mo/ 99m Tc generators were achieved from generator supported with 0.5 g Al 2 O 3 filter. Elution performance of 99m Tc radionuclide was highly dependent on the gel structural properties.

  18. Local perivascular delivery of anti-restenotic agents from a drug-eluting poly(ε-caprolactone) stent cuff

    NARCIS (Netherlands)

    Pires, N.M.M.; Hoeven, B.L. van der; Vries, M.R. de; Havekes, L.M.; Vlijmen, B.J. van; Hennink, W.E.; Quax, P.H.A.; Jukema, J.W.

    2005-01-01

    The introduction of drug-eluting stents (DES) to prevent in-stent restenosis is one of the major advances in interventional cardiology. Currently many types of DES are under evaluation for effectiveness and safety, a time-consuming and difficult procedure in humans. An animal model that allows rapid

  19. Association of Adventitial Vasa Vasorum and Inflammation With Coronary Hyperconstriction After Drug-Eluting Stent Implantation in Pigs In Vivo.

    Science.gov (United States)

    Nishimiya, Kensuke; Matsumoto, Yasuharu; Shindo, Tomohiko; Hanawa, Kenichiro; Hasebe, Yuhi; Tsuburaya, Ryuji; Shiroto, Takashi; Takahashi, Jun; Ito, Kenta; Ishibashi-Ueda, Hatsue; Yasuda, Satoshi; Shimokawa, Hiroaki

    2015-01-01

    The importance of adventitial inflammation has been implicated for the pathogenesis of coronary artery disease. However, the roles of adventitial changes in drug-eluting stent (DES)-induced coronary hyperconstriction remain largely unknown. In the present study, this issue in pigs in vivo with a special reference to adventitial vasa vasorum (VV) formation and Rho-kinase activation, a central mechanism of coronary vasospasm, was examined. Each animal received a sirolimus-eluting stent (SES) and a biolimus A9-eluting stent (BES), one in the left anterior descending and another in the left circumflex coronary arteries in a randomized manner (n=18). After 1, 3 and 6 months, coronary vasomotion was examined. At 1 month, coronary vasoconstriction to serotonin was significantly enhanced at the SES edges as compared with the BES edges (SES, 52±7% vs. BES, 22±3%, Pmicro-CT showed VV augmentation at the SES site, extending to the proximal and distal edges. Immunostainings demonstrated that VV formation, macrophage infiltration in the adventitia and Rho-kinase expressions/activation were significantly enhanced at the SES edges as compared with the BES edges. The DES with durable polymers enhances VV formation and inflammation in the adventitia, associating with the pathogenesis of DES-induced coronary hyperconstriction through Rho-kinase activation in pigs in vivo.

  20. Stents Eluting 6-Mercaptopurine Reduce Neointima Formation and Inflammation while Enhancing Strut Coverage in Rabbits.

    Directory of Open Access Journals (Sweden)

    Matthijs S Ruiter

    Full Text Available The introduction of drug-eluting stents (DES has dramatically reduced restenosis rates compared with bare metal stents, but in-stent thrombosis remains a safety concern, necessitating prolonged dual anti-platelet therapy. The drug 6-Mercaptopurine (6-MP has been shown to have beneficial effects in a cell-specific fashion on smooth muscle cells (SMC, endothelial cells and macrophages. We generated and analyzed a novel bioresorbable polymer coated DES, releasing 6-MP into the vessel wall, to reduce restenosis by inhibiting SMC proliferation and decreasing inflammation, without negatively affecting endothelialization of the stent surface.Stents spray-coated with a bioresorbable polymer containing 0, 30 or 300 μg 6-MP were implanted in the iliac arteries of 17 male New Zealand White rabbits. Animals were euthanized for stent harvest 1 week after implantation for evaluation of cellular stent coverage and after 4 weeks for morphometric analyses of the lesions.Four weeks after implantation, the high dose of 6-MP attenuated restenosis with 16% compared to controls. Reduced neointima formation could at least partly be explained by an almost 2-fold induction of the cell cycle inhibiting kinase p27Kip1. Additionally, inflammation score, the quantification of RAM11-positive cells in the vessel wall, was significantly reduced in the high dose group with 23% compared to the control group. Evaluation with scanning electron microscopy showed 6-MP did not inhibit strut coverage 1 week after implantation.We demonstrate that novel stents coated with a bioresorbable polymer coating eluting 6-MP inhibit restenosis and attenuate inflammation, while stimulating endothelial coverage. The 6-MP-eluting stents demonstrate that inhibition of restenosis without leaving uncovered metal is feasible, bringing stents without risk of late thrombosis one step closer to the patient.

  1. Randomized comparison between intracoronary β-radiation brachytherapy and implantation of paclitaxel-eluting stents for the treatment of diffuse in-stent restenosis

    International Nuclear Information System (INIS)

    Schukro, Christoph; Syeda, Bonni; Kirisits, Christian; Schmid, Rainer; Pichler, Philipp; Pokrajac, Boris; Lang, Irene; Poetter, Richard; Glogar, Dietmar

    2007-01-01

    Background and purpose: Intracoronary brachytherapy was the primary therapeutic option for the treatment of in-stent restenosis (ISR) during the last years. Especially for the treatment of diffuse ISR (lesions >10 mm), β-source brachytherapy was significantly superior to singular balloon angioplasty. Despite lacking clinical database, the implantation of drug eluting stents recently became a common procedure for the treatment of ISR. This randomized trial aimed to compare the efficacy of β-brachytherapy with β-radioisotopes 90 Sr/ 90 Y and paclitaxel-eluting stent implantation for the treatment of diffuse ISR. Material and methods: Thirty-seven patients with diffuse ISR were randomly assigned to β-brachytherapy after balloon angioplasty (Beta-Cath TM in 17 patients) or paclitaxel-eluting stent implantation (Taxus-Express2 TM in 20 patients). Six-month clinical follow-up was obtained for all patients, while angiographic follow-up was available for 30 patients. Results: Binary ISR (restenosis >50%) within target segment was observed in three patients treated with Beta-Cath TM , of which one needed target segment revascularisation for recurrent ISR, whereas no significant restenosis occurred in the patients treated with Taxus-Express2 TM (P = 0.037). No further major adverse cardiac (target segment revascularisation, myocardial infarction, death) was found in either group (P = NS). Stent implantation was the more time-saving (31 ± 11 min versus 60 ± 23 min, P TM arm, we found no difference in clinical outcome after implantation of paclitaxel-eluting stents for the treatment of diffuse ISR when compared to β-brachytherapy

  2. Three-year patient-related and stent-related outcomes of second-generation everolimus-eluting Xience V stents versus zotarolimus-eluting resolute stents in real-world practice (from the Multicenter Prospective EXCELLENT and RESOLUTE-Korea Registries).

    Science.gov (United States)

    Lee, Joo Myung; Park, Kyung Woo; Han, Jung-Kyu; Yang, Han-Mo; Kang, Hyun-Jae; Koo, Bon-Kwon; Bae, Jang-Whan; Woo, Sung-Il; Park, Jin Sik; Jin, Dong-Kyu; Jeon, Dong Woon; Oh, Seok Kyu; Park, Jong-Seon; Kim, Doo-Il; Hyon, Min Su; Jeon, Hui-Kyung; Lim, Do-Sun; Kim, Myeong-Gon; Rha, Seung-Woon; Her, Sung-Ho; Hwang, Jin-Yong; Kim, Sanghyun; Choi, Young Jin; Kang, Jin Ho; Moon, Keon-Woong; Jang, Yangsoo; Kim, Hyo-Soo

    2014-11-01

    Long-term outcomes are imperative to confirm safety of drug-eluting stents. There have been 2 randomized controlled trials comparing everolimus-eluting stents (EESs) and Resolute zotarolimus-eluting stents (ZES-Rs). To date, long-term clinical outcomes of these stents were limited to only 1 report, which has recently reported 4-year comparisons of these stents. Therefore, more evidence is needed regarding long-term clinical outcomes of the second-generation stents. This study compared the long-term clinical outcomes of EES with ZES-R in "all-comer" cohorts up to 3-year follow-up. The EXCELLENT and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with EES and 1,998 with ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure) and patient-related composite events up to 3-year follow-up were compared in crude and propensity score-matched analyses. Of 5,054 patients, 3,830 patients (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (189 [6.2%] vs 127 [6.4%], p = 0.812) and the patient-related outcome (420 [13.7%] vs 250 [12.5%], p = 0.581) did not differ between EES and ZES-R, respectively, at 3 years, which was corroborated by similar results from the propensity score-matched cohort (hazard ratio [HR] 0.92, 95% confidence interval [CI] 0.70 to 1.20, p = 0.523 and 0.85, 95% CI 0.70 to 1.02, p = 0.081, for stent- and patient-related outcomes, respectively). The rate of definite or probable stent thrombosis up to 3 years (22 [0.7%] vs 10 [0.5%], p = 0.370) was also similar. The rate of very late definite or probable stent thrombosis was very low and comparable between the 2 stents (3 [0.1%] vs 1 [0.1%], p = 0.657). In multivariate analysis, chronic renal failure (adjusted HR 3.615, 95% CI 2.440 to 5.354, p stents showed comparable safety and efficacy at 3-year follow-up in this robust real-world registry with unrestricted use of EES and

  3. Neutron activation analysis of trace metallic elements eluted from molecular sieves in the dehydration process of safflower oil

    Energy Technology Data Exchange (ETDEWEB)

    Takasago, Masahisa; Kobayashi, Koichi; Taru, Yasunori; Takaoka, Kyo (Musashi Inst. of Tech., Tokyo (Japan))

    1992-11-01

    Dissolved water in safflower oil affects the autoxidation of this oil significantly. Molecular sieves were used to remove the dissolved water from the oil. This method is much simpler than that of distillation, and dissolved water can be removed to the same extent as that by distillation. But, due to the elution of many kinds of trace metallic elements in the oil dehydrated with molecular sieves, these elements were analyzed by neutron activation analysis. For a data comparison trace amounts of metallic elements in the oil dehydrated by distillation were also analyzed. Since the intensity of the [gamma] ray-photoelectric peak of nuclide [sup 28]Al was largest among the detected elements, this element was analyzed quantitatively and the other elements qualitatively. In safflower oil dehydrated with molecular sieves, 14 kinds of the elements (I, Br, Al, Mg, Si, V, Cl, Nd, Ta, Cr, Sb, Cs, Co, Na) were detected. Also, I, Br, Cl, Cr, Ta, Sb, and Al elements were detected in the oil dehydrated by distillation. The intensity of the photoelectric peak of nuclide except [sup 28]Al was essentially the same as that in the oil dehydrated by distillation, but the intensity of [sup 28]Al in the oil with molecular sieves was about 28 times stronger than that in distillation oil. In the molecular sieves, 19 impure elements in addition to the original constituents (Na, K, Al, si, O) were detected. It was Al, Na, Si, Nd, Cs, and Co along with impure elements may possibly have been eluted in the oil. Al element in safflower oil dehydrated with molecular sieves was analyzed quantitatively. 0.91 ppm of Al was detected in safflower oil. The eluted amount of Al in safflower oil dehydrated by distillation was 0.032 ppm. A larger amount of Al element was thus eluted into the oil dehydrated with molecular sieves than by distillation. (author).

  4. Incidence of periprocedural myocardial infarction following stent implantation: Comparison between first- and second-generation drug-eluting stents

    NARCIS (Netherlands)

    Tandjung, Kenneth; Basalus, Mounir W.Z.; Muurman, Esther; Louwerenburg, Hans W.; van Houwelingen, Gert K.; Stoel, Martin G.; de Man, Frits H.A.F.; Jansen, Hanneke; Huisman, Jennifer; Linssen, Gerard C.M.; Droste, Herman T.; Nienhuis, Mark B.; von Birgelen, Clemens

    2012-01-01

    Background: First- and second-generation drug-eluting stents (DES) differ in coating materials, which may influence the incidence of periprocedural myocardial infarction (PMI). Objective: To compare the incidence of PMI between first- and second-generation DES, using the current Academic Research

  5. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis.

    Science.gov (United States)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-11-04

    To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; Pstents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. © Valgimigli et al 2014.

  6. Posterior reversible leukoencephalopathy syndrome secondary to hepatic transarterial chemoembolization with doxorubicin drug eluting beads

    Science.gov (United States)

    Kistler, C. Andrew; McCall, Joseph Caleb; Ghumman, Saad Sultan; Ali, Ijlal Akbar

    2014-01-01

    Posterior reversible encephalopathy syndrome (PRES) is a rare complication of transarterial chemoembolization (TACE) used to treat liver metastases and has never been reported in a patient with metastatic uveal melanoma (UM) to the liver. We report the first case of PRES secondary to TACE with drug eluting beads (DEBs) loaded with doxorubicin in a 56-year-old woman with metastatic UM to the liver. PMID:24772346

  7. A simple and robust quantitative analysis of retinol and retinyl palmitate using a liquid chromatographic isocratic method

    Directory of Open Access Journals (Sweden)

    Satoshi Yokota

    2018-04-01

    Full Text Available Vitamin A is a vital nutritional substances that regulates biological activities including development, but is also associated with disease onset. The extent of vitamin A intake influences the retinoid content in the liver, the most important organ for the storage of vitamin A. Measurement of endogenous retinoid in biological samples is important to understand retinoid homeostasis. Here we present a reliable, highly sensitive, and robust method for the quantification of retinol and retinyl palmitate using a reverse-phase HPLC/UV isocratic method. We determined the impact of chronic dietary vitamin A on retinoid levels in livers of mice fed an AIN-93G semi-purified diet (4 IU/g compared with an excess vitamin A diet (1000 IU/g over a period from birth to 10 weeks of age. Coefficients of variation for intra-assays for both retinoids were less than 5%, suggesting a higher reproducibility than any other HPLC/UV gradient method. Limits of detection and quantification for retinol were 0.08 pmol, and 0.27 pmol, respectively, which are remarkably higher than previous results. Supplementation with higher doses of vitamin A over the study period significantly increased liver retinol and retinyl palmitate concentrations in adult mice. The assays described here provide a sensitive and rigorous quantification of endogenous retinol and retinyl palmitate, which can be used to help determine retinoid homeostasis in disease states, such as toxic hepatitis and liver cancer. Keywords: Vitamin A excess, Retinol, Retinyl palmitate, Liver

  8. Impaired health status in Type D patients following PCI in the drug-eluting stent era

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Denollet, Johan; Ong, Andrew T L

    2007-01-01

    Drug-eluting stenting reduces restenosis post-percutaneous coronary intervention (PCI), but subgroups of patients may not benefit optimally from this procedure. We examined the impact of Type D personality on health status over time and the clinical relevance of Type D as a predictor of impaired...... health status at 12 months in unselected post-PCI patients....

  9. Protein Detection Using the Multiplexed Proximity Extension Assay (PEA) from Plasma and Vaginal Fluid Applied to the Indicating FTA Elute Micro CardTM

    OpenAIRE

    Berggrund, Malin; Ekman, Daniel; Gustavsson, Inger; Sundfeldt, Karin; Olovsson, Matts; Enroth, Stefan; Gyllensten, Ulf

    2016-01-01

    The indicating FTA elute micro cardTM has been developed to collect and stabilize the nucleic acid in biological samples and is widely used in human and veterinary medicine and other disciplines. This card is not recommended for protein analyses, since surface treatment may denature proteins. We studied the ability to analyse proteins in human plasma and vaginal fluid as applied to the indicating FTA elute micro cardTM using the sensitive proximity extension assay (PEA). Among 92 proteins in ...

  10. Determination of adulteration of malachite green in green pea and some prepared foodstuffs by micellar liquid chromatography.

    Science.gov (United States)

    Ashok, Vipin; Agrawal, Nitasha; Durgbanshi, Abhilasha; Esteve-Romero, Josep; Bose, Devasish

    2014-01-01

    A simple, fast, and robust micellar LC method was developed for the separation and identification of the nonpermitted color malachite green in green pea and some ready-to-eat foodstuffs. Malachite green (4-[(4-dimethylaminophenyl) phenyl-methyl]-N,N-dimethylaniline) is a hazardous dye that is used to treat fungal and protozoan infections in fish and is a common adulterant (coloring agent) in green pea and other green vegetables because of its green color. In the present work, malachite green was determined in various foodstuffs using a direct injection technique on an RP C18 column with isocratic elution. The optimum mobile phase consisted of 0.15 M sodium dodecyl sulfate (SDS), 6% pentanol buffered at pH 5. Detection was carried out at 620 nm. Malachite green was eluted in 9.2 min without any interference caused by endogenous compounds. Linearities (r > 0.9999), intraday and interday precision (RSD less than 1.00%) in micellar media, and robustness were studied for method validation. LOD and LOQ were 0.10 and 0.25 ppm, respectively. The simplicity of the developed method makes it useful for routine analysis in the area of food QC.

  11. Enantioseparation and chiral recognition mechanism of new chiral derivatives of xanthones on macrocyclic antibiotic stationary phases.

    Science.gov (United States)

    Fernandes, Carla; Tiritan, Maria Elizabeth; Cass, Quezia; Kairys, Visvaldas; Fernandes, Miguel Xavier; Pinto, Madalena

    2012-06-08

    A chiral HPLC method using four macrocyclic antibiotic chiral stationary phases (CSPs) has been investigated for determination of the enantiomeric purity of fourteen new chiral derivatives of xanthones (CDXs). The separations were performed with the CSPs Chirobiotic T, Chirobiotic TAG, Chirobiotic V and Chirobiotic R under multimodal elution conditions (normal-phase, reversed-phase and polar ionic mode). The analyses were performed at room temperature in isocratic mode and UV and CD detection at a wavelength of 254 nm. The best enantioselectivity and resolution were achieved on Chirobiotic R and Chirobiotic T CSPs, under normal elution conditions, with R(S) ranging from 1.25 to 2.50 and from 0.78 to 2.06, respectively. The optimized chromatographic conditions allowed the determination of the enantiomeric ratio of eight CDXs, always higher than 99%. In order to better understand the chromatographic behavior at a molecular level, and the structural features associated with the chiral recognition mechanism, computational studies by molecular docking were carried out using VDock. These studies shed light on the mechanisms involved in the enantioseparation for this important class of chiral compounds. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Type D personality predicts death or myocardial infarction after bare metal stent or sirolimus-eluting stent implantation

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Lemos, Pedro A; van Vooren, Priya R

    2004-01-01

    We investigated the effect of Type D personality on the occurrence of adverse events at nine months in patients with ischemic heart disease (IHD) after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SESs) or bare stents. Type D patients experience increased negative...

  13. Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials.

    Science.gov (United States)

    Bundhun, Pravesh Kumar; Yanamala, Chandra Mouli; Huang, Wei-Qiang

    2017-03-16

    Two thousand fifteen has been a winning year for Drug Eluting Stents (DES). Increase in the number of patients with cardiovascular diseases treated by Percutaneous Coronary Intervention (PCI) has resulted to a high demand for second generation DES. This current analysis aimed to compare the different types of Stent Thrombosis (ST) associated with Zotarolimus Eluting Stents (ZES) versus Everolimus Eluting Stents (EES) at 1 year follow up. Electronic databases were searched for studies comparing ZES with EES. Different types of ST reported at 1 year follow up were considered as the primary endpoints in this analysis. Odds Ratios (OR) with 95% Confidence Intervals (CIs) were used as the statistical parameters and the pooled analyses were carried out by the RevMan 5 · 3 software. A total number of 10,512 patients were included in this analysis. No significant difference in any definite ST, acute definite ST, subacute definite ST, and late definite ST were observed between ZES and EES, at 1 year follow up with OR: 1.70, 95% CI: 0.92 - 3.16; P = 0.09, OR: 3.44, 95% CI: 0.82 - 14.43; P = 0.09, OR: 1.13, 95% CI: 0.43 - 2.95; P = 0.80 and OR: 2.39, 95% CI: 0.83 - 6.85; P = 0.11 respectively. Moreover, any definite or probable ST and definite/probable/possible ST were also not significantly different with OR: 1.39, 95% CI: 0.89 - 2.17; P = 0.15 and OR: 1.19, 95% CI: 0.84 - 1.70; P = 0.33 respectively. In addition, any probable ST, acute probable ST, late probable ST and possible ST were also not significantly different at 1 year follow up with OR: 1.11, 95% CI: 0.60 - 2.05; P = 0.75, OR: 0.53, 95% CI: 0.12 - 2.40; P = 0.41, OR: 1.67, 95% CI: 0.35 - 7.86; P = 0.52 and OR: 1.08, 95% CI: 0.64 - 1.82; P = 0.78 respectively. At 1 year follow up, ZES were not associated with significantly lower or higher definite and probable ST compared to EES. In addition, no significant difference was observed in acute, subacute and late

  14. Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation

    DEFF Research Database (Denmark)

    Radu, Maria D; Räber, Lorenz; Heo, Jungho

    2014-01-01

    history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. METHODS...

  15. Recovery of phosphorus and aluminium from sewage sludge ash by a new wet chemical elution process (SESAL-Phos-recovery process).

    Science.gov (United States)

    Petzet, S; Peplinski, B; Bodkhe, S Y; Cornel, P

    2011-01-01

    The potential of a new wet chemical process for phosphorus and aluminium recovery from sewage sludge ash by sequential elution with acidic and alkaline solutions has been investigated: SESAL-Phos (sequential elution of sewage sludge ash for aluminium and phosphorus recovery). Its most innovative aspect is an acidic pre-treatment step in which calcium is leached from the sewage sludge ash. Thus the percentage of alkaline soluble aluminium phosphates is increased from 20 to 67%. This aluminium phosphate is then dissolved in alkali. Subsequently, the dissolved phosphorus is precipitated as calcium phosphate with low heavy metal content and recovered from the alkaline solution. Dissolved aluminium is recovered and may be reused as a precipitant in wastewater treatment plants.

  16. The sirolimus-eluting Cypher Select coronary stent for the treatment of bare-metal and drug-eluting stent restenosis: insights from the e-SELECT (Multicenter Post-Market Surveillance) registry.

    Science.gov (United States)

    Abizaid, Alexandre; Costa, J Ribamar; Banning, Adrian; Bartorelli, Antonio L; Dzavik, Vladimir; Ellis, Stephen; Gao, Runlin; Holmes, David R; Jeong, Muyng Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Orlick, Amy; Spaulding, Christian; Worthley, Stephen; Urban, Philip M

    2012-01-01

    This study sought to compare the 1-year safety and efficacy of Cypher Select or Cypher Select Plus (Cordis Corporation, Bridgewater, New Jersey) sirolimus-eluting stents (SES) with the treatment of bare-metal stents (BMS) and drug-eluting stent (DES) in-stent restenosis (ISR) in nonselected, real-world patients. There is paucity of consistent data on DES for the treatment of ISR, especially, DES ISR. The e-SELECT (Multicenter Post-Market Surveillance) registry is a Web-based, multicenter and international registry encompassing virtually all subsets of patients and lesions treated with at least 1 SES during the period from 2006 to 2008. We enrolled in this pre-specified subanalysis all patients with at least 1 clinically relevant BMS or DES ISR treated with SES. Primary endpoint was major adverse cardiac events and stent thrombosis rate at 1 year. Of 15,147 patients enrolled, 1,590 (10.5%) presented at least 1 ISR (BMS group, n = 1,235, DES group, n = 355). Patients with DES ISR had higher incidence of diabetes (39.4% vs. 26.9%, p target lesion revascularization and definite/probable late stent thrombosis were higher in patients with DES ISR (6.9% vs. 3.1%, p = 0.003, and 1.8% vs. 0.5%, p = 0.04, respectively). Use of SES for either BMS or DES ISR treatment is safe and associated with low target lesion revascularization recurrence and no apparent safety concern. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Investigations on the elution behaviour of TOPO complexes of uranium and thorium using supercritical fluid chromatography

    International Nuclear Information System (INIS)

    Kumar, R.; Sivaraman, N.; Srinivasan, T.G.; Vasudeva Rao, P.R.

    2004-01-01

    In summary uranium and thorium could be separated by supercritical fluid chromatography technique as their TOPO complexes. The elution profiles with pre-complexation of the metal nitrate indicate a better separation than the in-situ complexation. The technique can also be employed for the assay of uranium and thorium at low levels

  18. Chromatin structure influence of DNA damage measurements by four assays: pulsed- and constant-field gel electrophoresis, DNA precipitation and non-denaturing filter elution

    International Nuclear Information System (INIS)

    Wlodek, D.; Olive, P.L.

    1996-01-01

    The of elution of DNA during non-denaturing filter elution (NFE) often correlates with cell sensitivity to radiation. The elution rate is influenced by two cellular factors: chromatin structure and the number of DNA-strand breaks (DSBs) produced in an intact cell by ionizing radiation. To determine which of the above factors is relevant to cell radiosensitivity, four assays were used to measure induction of DNA damage in three cell lines varying in radiosensitivity (V79, CHO, and L5178Y-R). Each of the assays, neutral filter elution (NFE), DNA precipitation, constant (CFGE) and pulsed field gel electrophoresis (PFGE) have different physical basis for DNA damage measurement and might be differently affected by chromatin structure. Three of the methods used to measure DNA double-strand breaks gave different results: NFE was dependent on cell type and location of DNA relative to the replication fork, gel electrophoresis was independent of cell type but was affected by proximity to the replication fork, and the precipitation assay was independent of both cell type and replication status. Pulsed field gel electrophoresis produced the same results and constant field gel electrophoresis for 3 cell lines examined. Only NFE showed differences in sensitivity which correlated with cell survival following irradiation. The results suggest that three is the same initial amount of DSBs in cells from all three lines and that the sensitivity to radiation is determined by some additional factors, probably chromatin structure. (author). 18 refs, 5 figs

  19. Determination of citrus limonoid glucosides by high performance liquid chromatography coupled to post-column reaction with Ehrlich’s Reagent

    Science.gov (United States)

    A method for the identification and quantification of citrus limonoid glucosides in juices based upon high performance liquid chromatography (HPLC) separation coupled to post-column reaction with Ehrlichs’s reagent has been developed. This method utilizes a phenyl stationary phase and an isocratic ...

  20. Detachable strong cation exchange monolith, integrated with capillary zone electrophoresis and coupled with pH gradient elution, produces improved sensitivity and numbers of peptide identifications during bottom-up analysis of complex proteomes.

    Science.gov (United States)

    Zhang, Zhenbin; Yan, Xiaojing; Sun, Liangliang; Zhu, Guijie; Dovichi, Norman J

    2015-04-21

    A detachable sulfonate-silica hybrid strong cation-exchange monolith was synthesized in a fused silica capillary, and used for solid phase extraction with online pH gradient elution during capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) proteomic analysis. Tryptic digests were prepared in 50 mM formic acid and loaded onto the strong cation-exchange monolith. Fractions were eluted using a series of buffers with lower concentration but higher pH values than the 50 mM formic acid background electrolyte. This combination of elution and background electrolytes results in both sample stacking and formation of a dynamic pH junction and allows use of relatively large elution buffer volumes while maintaining reasonable peak efficiency and resolution. A series of five pH bumps were applied to elute E. coli tryptic peptides from the monolith, followed by analysis using CZE coupled to an LTQ-Orbitrap Velos mass spectrometer; 799 protein groups and 3381 peptides were identified from 50 ng of the digest in a 2.5 h analysis, which approaches the identification rate for this organism that was obtained with an Orbitrap Fusion. We attribute the improved numbers of peptide and protein identifications to the efficient fractionation by the online pH gradient elution, which decreased the complexity of the sample in each elution step and improved the signal intensity of low abundance peptides. We also performed a comparative analysis using a nanoACQUITY UltraPerformance LCH system. Similar numbers of protein and peptide identifications were produced by the two methods. Protein identifications showed significant overlap between the two methods, whereas peptide identifications were complementary.

  1. Correlates and Impact of Coronary Artery Calcifications in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents

    DEFF Research Database (Denmark)

    Giustino, Gennaro; Mastoris, Ioannis; Baber, Usman

    2016-01-01

    OBJECTIVES: The aim of this study was to investigate the clinical correlates and prognostic impact of coronary artery calcification (CAC) in women undergoing percutaneous coronary intervention with drug-eluting stents (DES). BACKGROUND: The clinical correlates and the prognostic significance of CAC...

  2. Novel HPLC Analysis of Hydrocortisone in Conventional and Controlled-Release Pharmaceutical Preparations

    Directory of Open Access Journals (Sweden)

    Ofosua Adi-Dako

    2017-01-01

    Full Text Available An isocratic sensitive and precise reverse phase high-performance liquid chromatography (RP-HPLC method was developed and validated for the determination and quantification of hydrocortisone in controlled-release and conventional (tablets and injections pharmaceutical preparations. Chromatographic separation was achieved on an ODS (C18, 5 μm, 4.6 × 150 mm, with an isocratic elution using a freshly prepared mobile phase of composition methanol : water : acetic acid (60 : 30 : 10, v/v/v at a flow rate of 1.0 ml/min. The detection of the drug was successfully achieved at a wavelength of 254 nm. The retention time obtained for the drug was 2.26 min. The proposed method produced linear detectable responses in the concentration range of 0.02 to 0.4 mg/ml of hydrocortisone. High recoveries of 98–101% were attained at concentration levels of 80%, 100%, and 120%. The intraday and interday precision (RSD were 0.19–0.55% and 0.33–0.71%, respectively. A comparison of hydrocortisone analyses data from the developed method and the official USP method showed no significant difference (p>0.05 at a 95% confidence interval. The method was successfully applied to the determination and quantification of hydrocortisone in six controlled-release and fifteen conventional release pharmaceutical preparations.

  3. Functional Nanoarchitectures For Enhanced Drug Eluting Stents

    Science.gov (United States)

    Saleh, Yomna E.; Gepreel, Mohamed A.; Allam, Nageh K.

    2017-01-01

    Different strategies have been investigated to allow for optimum duration and conditions for endothelium healing through the enhancement of coronary stents. In this study, a nanoarchitectured system is proposed as a surface modification for drug eluting stents. Highly oriented nanotubes were vertically grown on the surface of a new Ni-free biocompatible Ti-based alloy, as a potential material for self-expandable stents. The fabricated nanotubes were self-grown from the potential stent substrate, which are also proposed to enhance endothelial proliferation while acting as drug reservoir to hinder Vascular Smooth Muscle Cells (VSMC) proliferation. Two morphologies were synthesized to investigate the effect of structure homogeneity on the intended application. The material was characterized by field-emission scanning electron microscope (FESEM), X-ray diffraction (XRD), Raman spectroscopy, energy dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS). Nanoindentation technique was used to study the mechanical properties of the fabricated material. Cytotoxicity and proliferation studies were performed and compared for the two fabricated nanoarchitectures, versus smooth untextured samples, using in-vitro cultured endothelial cells. Finally, the drug loading capacity was experimentally studied and further supported by computational modeling of the release profile.

  4. Resolution of co-eluting compounds of Cannabis Sativa in comprehensive two-dimensional gas chromatography/mass spectrometry detection with Multivariate Curve Resolution-Alternating Least Squares.

    Science.gov (United States)

    Omar, Jone; Olivares, Maitane; Amigo, José Manuel; Etxebarria, Nestor

    2014-04-01

    Comprehensive Two Dimensional Gas Chromatography - Mass Spectrometry (GC × GC/qMS) analysis of Cannabis sativa extracts shows a high complexity due to the large variety of terpenes and cannabinoids and to the fact that the complete resolution of the peaks is not straightforwardly achieved. In order to support the resolution of the co-eluted peaks in the sesquiterpene and the cannabinoid chromatographic region the combination of Multivariate Curve Resolution and Alternating Least Squares algorithms was satisfactorily applied. As a result, four co-eluting areas were totally resolved in the sesquiterpene region and one in the cannabinoid region in different samples of Cannabis sativa. The comparison of the mass spectral profiles obtained for each resolved peak with theoretical mass spectra allowed the identification of some of the co-eluted peaks. Finally, the classification of the studied samples was achieved based on the relative concentrations of the resolved peaks. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Forced degradation of mometasone furoate and development of two RP-HPLC methods for its determination with formoterol fumarate or salicylic acid

    Directory of Open Access Journals (Sweden)

    Ramzia I. El-Bagary

    2016-05-01

    Full Text Available Two simple, selective and precise stability-indicating reversed-phase liquid chromatographic methods were developed and validated for the determination of mometasone furoate in two binary mixtures, with formoterol fumarate (Mixture 1 and salicylic acid (Mixture 2. Also, a forced degradation study of mometasone furoate was carried out including acid and alkali hydrolysis, oxidation, thermal and photo-degradation. For mixture 1, the method was based on isocratic elution using a mobile phase consisting of (Acetonitrile: 3 mM Sodium lauryl sulfate (60:40, v/v at a flow rate of 1 ml min−1. Quantitation was achieved applying dual wavelength detection where mometasone furoate and its degradation products were detected at 247 nm and formoterol fumarate and its degradation product were detected at 214 nm at 30 °C. For mixture 2 and for the forced degradation study, separation was based on isocratic elution of mometasone furoate, its degradation products and salicylic acid on a reversed phase C8 column using a mobile phase consisting of acetonitrile:water:methanol:glacial acetic acid (60:30:10:0.1, v/v at a flow rate of 2 mL min−1. Quantitation was achieved with UV detection at 240 nm. In addition, products from alkaline forced degradation of mometasone furoate were verified by LC–MS. Linearity, accuracy and precision were found to be acceptable over the concentration range of 10–800 μg mL−1 and 5–60 μg mL−1 for mometasone furoate and formoterol fumarate, respectively and over the concentration range of 5–320 μg mL−1 and 20–1280 μg mL−1 for mometasone furoate and salicylic acid, respectively. The two proposed methods could be successfully applied for the routine analysis of the studied drugs in their pharmaceutical preparations without any preliminary separation step.

  6. Stability-Indicating RP-HPLC Methods for the Determination of Fluorometholone in Its Mixtures with Sodium Cromoglycate and Tetrahydrozoline Hydrochloride.

    Science.gov (United States)

    El-Bagary, Ramzia I; Fouad, Marwa A; El-Shal, Manal A; Tolba, Enas H

    2016-07-01

    Two stability-indicating reversed-phase liquid chromatographic methods were developed and validated for the determination of fluorometholone (FLU) in its mixtures with sodium cromoglycate (SCG) and tetrahydrozoline hydrochloride (THZ). The first HPLC method (Method 1) was based on isocratic elution of FLU and SCG along with their alkaline degradation products on a reversed phase C18 column (250 × 4.6 mm id)-ACE Generix 5, using a mobile phase consisting of methanol-water (70 : 30, v/v), pH adjusted to 2.5 using orthophosphoric acid at a flow rate of 1.2 mL min(-1) Quantitation was achieved with UV detection at 240 nm. The second HPLC method (Method 2) was based on isocratic elution of FLU, its alkaline degradation product and THZ on a reversed phase C8 column (250 × 4.6 mm)-ACE Generix 5, using a mobile phase consisting of acetonitrile-50 mM potassium dihydrogen orthophosphate (40 : 60, v/v) at a flow rate of 2 mL min(-1) Quantitation was achieved by applying dual-wavelength detection, where FLU and its alkaline degradation product were detected at 240 nm and THZ was detected at 215 nm at ambient temperatures. Linearity, accuracy and precision were found to be acceptable over the concentration range of 5-50 and 10-500 μg mL(-1) for FLU and SCG (Method 1) and over the concentration range of 5-80 and 5-60 μg mL(-1) for FLU and THZ (Method 2), respectively. Besides, the FLU alkaline degradation product was verified using IR, NMR and LC-MS spectroscopy. The two proposed methods could be successfully applied for the routine analysis of the studied drugs either in their pure bulk powders or in their pharmaceutical preparations without any preliminary separation step. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Reduction of Solvent Effect in Reverse Phase Gradient Elution LC-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Patrick Allen [Iowa State Univ., Ames, IA (United States)

    2005-12-17

    %-35% (simulated) and 8%-32% (actual). Quadrupole (low resolution) and sector field (high resolution) ICP-MS instrumentation were utilized in these studies. Once an AIS pair is determined, quantification studies can be performed. First, an analysis is performed by adding both elements of the AIS pair post-column while performing the gradient elution without sample injection. A comparison of the ratio of the measured intensities to the atomic ratio of the two standards is used to determine a correction factor that can be used to account for the matrix effects caused by the mobile phase. Then, organic and/or biological molecules containing one of the two elements in the AIS pair are injected into the LC column. A gradient method is used to vary the methanol-water mixture in the mobile phase and to separate out the compounds in a given sample. A standard solution of the second ion in the AIS pair is added continuously post-column. By comparing the ratio of the measured intensities to the atomic ratio of the eluting compound and internal standard, the concentration of the injected compound can be determined.

  8. Determination of undecylenic and sorbic acids in cosmetic preparations by high performance liquid chromatography with electrochemical detection.

    Science.gov (United States)

    Bousquet, Ennio; Spadaro, A; Santagati, N A; Scalia, S; Ronsisvalle, G

    2002-11-07

    A highly sensitive and selective method for the determination of sorbic (SA) and undecylenic acid (UA) in cosmetic formulations by a high performance liquid chromatography method with electrochemical detection (ECD) is described. The pre-column derivatizations of SA and UA and the internal standard (cyclohexanoic acid (cHA)) were carried out using 1-(2,5-dihydroxyphenyl)-2-bromoethanone (2,5-DBE) as an electroactive labeling reagent previously synthesized in our lab. The resulting electroactive esters were separated by isocratic elution of a 5 micrometer Hypersil CN column with acetonitrile-acetate buffer eluent. The compounds were detected by a porous graphite electrode set at an oxidation potential of +0.45 V. The analytical method developed in this study is suitable for quality control assays of complex cosmetic formulations containing sorbic and/or UA.

  9. A novel HPLC method for the concurrent analysis and quantitation of seven water-soluble vitamins in biological fluids (plasma and urine): a validation study and application.

    Science.gov (United States)

    Giorgi, Margherita Grotzkyj; Howland, Kevin; Martin, Colin; Bonner, Adrian B

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B(1), B(2), B(5), B(6), B(9), B(12)) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were vitamins. Recovery percentages ranged from 93% to 100%.

  10. High performance liquid chromatography method for the determination of cinnamyl alcohol dehydrogenase activity in soybean roots.

    Science.gov (United States)

    dos Santos, W D; Ferrarese, Maria de Lourdes Lucio; Ferrarese-Filho, O

    2006-01-01

    This study proposes a simple, quick and reliable method for determining the cinnamyl alcohol dehydrogenase (CAD; EC 1.1.1.195) activity in soybean (Glycine max L. Merr.) roots using reversed-phase high performance liquid chromatography (RP-HPLC). The method includes a single extraction of the tissue and conduction of the enzymatic reaction at 30 degrees C with cinnamaldehydes (coniferyl or sinapyl), substrates of CAD. Disappearance of the substrates in the reaction mixture is monitored at 340 nm (for coniferaldehyde) or 345 nm (for sinapaldehyde) by isocratic elution with methanol/acetic acid through a GLC-ODS (M) column. This HPLC technique furnishes a rapid and reliable measure of cinnamaldehyde substrates, and may be used as an alternative tool to analyze CAD activity in enzyme preparation without previous purification.

  11. Development and Validation of HPLC-PDA Assay method of Frangula emodin

    Directory of Open Access Journals (Sweden)

    Deborah Duca

    2016-03-01

    Full Text Available Frangula emodin, (1,3,8-trihydroxy-6-methyl-anthraquinone, is one of the anthraquinone derivatives found abundantly in the roots and bark of a number of plant families traditionally used to treat constipation and haemorrhoids. The present study describes the development and subsequent validation of a specific Assay HPLC method for emodin. The separation was achieved on a Waters Symmetry C18, 4.6 × 250 mm, 5 μm particle size, column at a temperature of 35 °C, with UV detection at 287 and 436 nm. An isocratic elution mode consisting of 0.1% formic acid and 0.01% trifluoroacetic acid as the aqueous mobile phase, and methanol was used. The method was successfully and statistically validated for linearity, range, precision, accuracy, specificity and solution stability.

  12. High-performance liquid chromatography for determination of α-tocopherol in vegetables

    Directory of Open Access Journals (Sweden)

    Marcin Horbowicz

    2013-12-01

    Full Text Available A simple method for the determination of α-tocopherol in vegetables is described. The procedure consists of the following steps: saponification, extraction, silica-column clean-up, and high-performance liquid chromatography. Elution time for D, L-α-tocopherol was 9.0 min using a Zorbax Sil (250 x 4.6 mm column and an isocratic mobile phase of hexane-methanol (99.3 + 0.7, with a flow rate of 1 ml/min, and detection at 292 nm using a variable UV detector. The average recovery of α-tocopherol was 91.2%, and the minimum detectable amount was 0.1 mg/100 g of fresh vegetable tissue. This method is comparable to gas-chromatographic determination of α-tocopherol, but has fewer analytical steps and gives more reproducible results.

  13. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young; Yuk, Soon Hong; Lee, Yong Seok

    2005-01-01

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models

  14. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yuk, Soon Hong [Hannam University, College of Engineering, Daejeon (Korea, Republic of); Lee, Yong Seok [Wonkwang University College of Medicine, Iksan (Korea, Republic of)

    2005-07-15

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models.

  15. Development of DNA elution method to detect irradiated foodstuff

    International Nuclear Information System (INIS)

    Copin, M.P.; Bourgeois, C.M.

    1991-01-01

    The aim of the work is to develop a reliable method to detect whether a fresh and frozen foodstuff has been irradiated. The molecule of DNA is one of the targets of ionizing radiation. The induction of three major classes of lesion have been shown. Double strand breaks, single strand breaks and base damage. Among the different techniques used to observe and quantify the strand breaks, techniques of elution are very interesting. The method proposed consisted of a filtration of the DNA at the atmospheric pressure and in non denaturing conditions. The amount of DNA retained on the filter is measured after being suitably labelled by microfluorometry. A difference in the amount of DNA retained on a filter of 2 μm from a lysed muscular tissue sample between a frozen Norway lobster which has been irradiated and one which has not, is observed. 7 refs

  16. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  17. The REMEDEE-OCT Study: An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis

    NARCIS (Netherlands)

    Jaguszewski, Milosz; Aloysius, Romila; Wang, Wei; Bezerra, Hiram G.; Hill, Jonathan; de Winter, Robbert J.; Karjalainen, Pasi P.; Verheye, Stefan; Wijns, William; Lüscher, Thomas F.; Joner, Michael; Costa, Marco; Landmesser, Ulf

    2017-01-01

    The aim of the present study was to evaluate vascular healing of the bioengineered COMBO Dual Therapy Stent compared with a cobalt-chromium (CoCr) everolimus-eluting stent (EES) as assessed by optical coherence tomography in patients with acute coronary syndromes. CD34+ cells promote endothelial

  18. Chronic Kidney Disease in the Second-Generation Drug-Eluting Stent Era: Pooled Analysis of the Korean Multicenter Drug-Eluting Stent Registry.

    Science.gov (United States)

    Lee, Joo Myung; Kang, Jeehoon; Lee, Euijae; Hwang, Doyeon; Rhee, Tae-Min; Park, Jonghanne; Kim, Hack-Lyoung; Lee, Sang Eun; Han, Jung-Kyu; Yang, Han-Mo; Park, Kyung Woo; Na, Sang-Hoon; Kang, Hyun-Jae; Koo, Bon-Kwon; Kim, Hyo-Soo

    2016-10-24

    The purpose of this study was to evaluate the clinical impact of chronic kidney disease (CKD) on clinical outcomes in contemporary practice of percutaneous coronary intervention (PCI) using second-generation drug-eluting stents (DES). Although second-generation DES have improved the safety and efficacy issues in PCI, data regarding the performance of second-generation DES in patients with CKD are still limited. We performed a patient-level pooled analysis on 12,426 patients undergoing PCI using second-generation DES from the Korean Multicenter Drug-Eluting Stent Registry. Endpoints were stent-oriented outcomes (target lesion failure [TLF]) and patient-oriented composite outcomes (POCO) during a median follow-up of 35 months. CKD patients were stratified by the estimated glomerular filtration rate (eGFR) from mild CKD to end-stage renal disease patients, and by the coexistence of diabetes mellitus (DM). A total of 2,927 patients had CKD (23.6%), who showed a significantly higher risk of TLF (adjusted hazard ratio [HR adjust ]: 1.50; 95% confidence interval [CI]: 1.21 to 1.86) and POCO (HR adjust 1.34; 95% CI: 1.17 to 1.55) compared to patients with preserved renal function. Stratified analysis by eGFR showed that TLF was not increased in the mild to moderate CKD, whereas severe CKD and dialysis-dependent patients showed significantly higher risk of TLF (HR adjust 2.44; 95% CI: 1.54 to 3.86; HR adjust 3.58; 95% CI: 2.52 to 5.08, respectively). The eGFR threshold of increased clinical events was 40 to 45 ml/min/1.73 m 2 . Among CKD patients, DM CKD patients showed a higher incidence of TLF compared to non-DM CKD patients (HR adjust : 1.82; 95% CI: 1.32 to 2.52), driven by the increase in target vessel-related events. In the era of second-generation DES, CKD patients were at a significantly higher risk of clinical outcomes only in severe CKD and end-stage renal disease patients. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All

  19. Lysis solution composition and non-linear dose-response to ionizing radiation in the non-denaturing DNA filter elution technique

    International Nuclear Information System (INIS)

    Radford, I.R.

    1990-01-01

    The suggestion by Okayasu and Iliakis (1989) that the non-linear dose-response curve, obtained with the non-denaturing filter elution technique for mammalian cells exposed to low-LET radiation, is the result of a technical artefact, was not confirmed. (author)

  20. Quantification of Temozolomide in Nonhuman Primate Fluids by Isocratic Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry to Study Brain Tissue Penetration Following Intranasal or Intravenous Delivery

    Directory of Open Access Journals (Sweden)

    Cody J. Peer

    2016-02-01

    Full Text Available A sensitive and selective ultra-high performance liquid chromatography-tandem mass spectrometric method was developed for the quantification of temozolomide (TMZ in nonhuman primate (NHP plasma, cerebrospinal fluid (CSF, and brain extracellular fluid (ECF following microdialysis. Ethyl acetate was used to extract the plasma and CSF samples, using theophylline as the internal standard (IS. ECF samples were diluted with acetonitrile prior to analysis. TMZ was separated on a Waters UPLC® BEH C18 column with an isocratic mobile phase of ammonium acetate (10 mM-0.1% formic acid/acetonitrile (30:70, v/v in a positive-ion multiple reaction monitoring mode (m/z 195.5→137.6 for TMZ; m/z 181.5→124.2 for IS. The retention time of TMZ and theophylline was 0.45 min with a total run time of 2.5 min. The method was validated over the range from 5–2000 ng/mL in NHP plasma, CSF, and ECF with respect to linearity, accuracy, precision, selectivity, and stability. This method was successfully applied toward the measurement of pharmacokinetic samples following various routes of drug administration.

  1. Toxicity of Irinotecan-Eluting Beads in the Treatment of Hepatic Malignancies: Results of a Multi-Institutional Registry

    International Nuclear Information System (INIS)

    Martin, R. C. G.; Howard, J.; Tomalty, D.; Robbins, K.; Padr, R.; Bosnjakovic, P. M.; Tatum, Cliff

    2010-01-01

    PurposeTo evaluate the predictors of toxicity of drug-eluting beads loaded with irinotecan (DEBIRI) in the treatment of hepatic malignancies.Materials and MethodsA total of 330 patients were enrolled in a prospective, open-label, multicenter, multinational, single-arm study administering two types of drug-eluting beads (DEBIRI and drug-eluting beads loaded with doxorubicin). Complications were graded by Cancer Therapy Evaluation Program's Common Terminology Criteria for Adverse Events (CTCAE) version 3.0. All events requiring additional physician treatment or requiring extended hospital stay or readmission within 30 days were included.ResultsA total of 109 patients received 187 DEBIRI treatments (range 1 to 5 per patient). The most common histology was metastatic colorectal cancer in 76% of patients, cholangiocarcinoma in 7% of patients, and other metastatic disease in 17% of patients. There were 35 patients (19%) with irinotecan treatments who sustained 158 treatment-related adverse events, with the median CTCAE event grade being CTCAE grade 2 (range 1 to 5). The most common adverse events were postembolic symptoms (42%). Multivariate analysis identified pretreatment and treatment-related risk factors as follows: lack of pretreatment with hepatic arterial lidocaine (p = 0.005), ≥3 treatments (p = 0.05), achievement of complete stasis (p = 0.04), treatment with >100 mg DEBIRI in 1 treatment (p = 0.03), and bilirubin >2.0 μg/dl with >50% liver involvement (p = 0.05). These factors were predictive of adverse events and significantly greater hospital length of stay.ConclusionsDEBIRI is safe when appropriate technique and treatment are used. Adverse events can be predicted based on pretreatment- and treatment-related factors, and their occurrence can become part of the informed consent process. Continued standardization of this treatment will lead to fewer adverse events and improved patient quality of life.

  2. High-affinity RNA aptamers to C-reactive protein (CRP): newly developed pre-elution methods for aptamer selection

    International Nuclear Information System (INIS)

    Orito, N; Umekage, S; Sakai, E; Tanaka, T; Kikuchi, Y; Sato, K; Kawauchi, S; Tanaka, H

    2012-01-01

    We have developed a modified SELEX (systematic evolution of ligands by exponential enrichment) method to obtain RNA aptamers with high affinity to C-reactive protein (CRP). CRP is a clinical biomarker present in plasma, the level of which increases in response to infections and noninfectious inflammation. The CRP level is also an important prognostic indicator in patients with several syndromes. At present, CRP content in blood is measured immunochemically using antibodies. To develop a more sensitive method using RNA aptamers, we have attempted to obtain high-affinity RNA aptamers to CRP. We succeeded in obtaining an RNA aptamer with high affinity to CRP using a CRP-immobilized Sepharose column and pre-elution procedure. Pre-elution is a method that removes the weak binding portion from a selected RNA population by washing for a short time with buffer containing CRP. By surface plasmon-resonance (SPR) analysis, the affinity constant of this aptamer for CRP was calculated to be K D = 2.25x10 -9 (M). The secondary structure, contact sites with CRP protein, and application of this aptamer will be described.

  3. Microchip electrospray: improvements in spray and signal stability during gradient elution by an inverted postcolumn makeup flow.

    Science.gov (United States)

    Jung, Stephanie; Effelsberg, Uwe; Tallarek, Ulrich

    2011-12-01

    Dynamic changes in mobile phase composition during high-performance liquid chromatography (HPLC) gradient elution coupled to mass spectrometry (MS) sensitively affect electrospray modes. We investigate the impact of the eluent composition on spray stability and MS response by infusion and injection experiments with a small tetrapeptide in water-acetonitrile mixtures. The employed HPLC/electrospray (ESI)-MS configuration uses a microchip equipped with an enrichment column, a separation column, and a makeup flow (MUF) channel. One nano pump is connected to the separation column, while a second one delivers solvent of exactly inverted composition to the MUF channel. Both solvent streams are united behind the separation column, before the ESI tip, such that the resulting electrosprayed solution always has identical composition during a gradient elution. Analyte peak parameters without and with MUF compensation are determined and discussed with respect to the electrospray mode and eluent composition. The postcolumn MUF significantly improves spray and signal stability over the entire solvent gradient, without compromising the performance of the HPLC separation column. It can also be conveniently implemented on microchip platforms.

  4. Single-Stage Treatment of Osteomyelitis for Digital Salvage by Using an Antibiotic-Eluting, Methylmethacrylate Joint-Spanning Spacer.

    Science.gov (United States)

    Aimé, Victoria L; Kidwell, John T; Webb, Leland H

    2017-06-01

    Osteomyelitis of the digit is a challenging problem that can result in amputation. We describe 13 cases of osteomyelitis involving bones of the hand managed with a novel technique. We reviewed records of 12 patients (13 digits) who had joint-spanning, antibiotic-eluting (tobramycin or vancomycin), methylmethacrylate spacers placed as definitive, single-stage treatment for digital osteomyelitis. The primary outcome was digit salvage. Secondary outcomes were infection eradication (no recurrence at 3 months) and spacer removal. Patients were followed up until the infection resolved (ie, no cutaneous signs of infection, including pain, erythema, or swelling). At a mean of 24 months, 10 of 13 infections had successful one-stage treatment. One patient required a second operation to revise a soft tissue flap but the spacer remained in place. Two spacers were removed because of malalignment. An antibiotic-eluting methylmethacrylate spacer is an innovative treatment for digital osteomyelitis. In 12 consecutive patients (13 digits), we successfully salvaged the digit. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Towards Hypoxia-responsive Drug-eluting Embolization Beads.

    Science.gov (United States)

    Ashrafi, Koorosh; Heaysman, Clare L; Phillips, Gary J; Lloyd, Andrew W; Lewis, Andrew L

    2017-05-30

    Drug release from chemoembolization microspheres stimulated by the presence of a chemically reducing environment may provide benefits for targeting drug resistant and metastatic hypoxic tumours. A water-soluble disulfide-based bifunctional cross-linker bis(acryloyl)-(l)-cystine (BALC) was synthesised, characterised and incorporated into a modified poly(vinyl) alcohol (PVA) hydrogel beads at varying concentrations using reverse suspension polymerisation. The beads were characterised to confirm the amount of cross-linker within each formulation and its effects on the bead properties. Elemental and UV/visible spectroscopic analysis confirmed the incorporation of BALC within the beads and sizing studies showed that in the presence of a reducing agent, all bead formulations increased in mean diameter. The BALC beads could be loaded with doxorubicin hydrochloride and amounts in excess of 300mg of drug per mL of hydrated beads could be achieved but required conversion of the carboxylic acid groups of the BALC to their sodium carboxylate salt forms. Elution of doxorubicin from the beads demonstrated a controlled release via ionic exchange. Some formulations exhibited an increase in size and release of drug in the presence of a reducing agent, and therefore demonstrated the ability to respond to an in vitro reducing environment. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Characterization of crude oils and petroleum products: (I Elution liquid chromatographic separation and gas chromatographic analysis of crude oils and petroleum products

    Directory of Open Access Journals (Sweden)

    E.O. Odebunmi

    2002-12-01

    Full Text Available Some physical and chemical properties of samples of light, medium and heavy Nigerian crude oils and petroleum products including gasoline, kerosene and engine oil have been measured and are reported in this paper. The crude oils and petroleum products have also been characterized by fractional distillation and elution liquid chromatography. The fractions obtained from elution liquid chromatography were analyzed using gas chromatography (GC. The GC fractions were identified by comparing the retention time of peaks in the unknown samples with those of components of calibration standard mixtures. The importance of the physico-chemical properties and the significance of the fractional distillation and chromatographic separation methods to industrial process operations have been discussed.

  7. Magmaris: a new generation metallic sirolimus-eluting fully bioresorbable scaffold: present status and future perspectives

    OpenAIRE

    Rapetto, Claudio; Leoncini, Massimo

    2017-01-01

    Drug-eluting stents (DES) have reached a high safety and efficacy profile, becoming the best option for percutaneous coronary interventions (PCI) based revascularization. However, despite their optimal performance, a few concerns remain regarding their use, mainly due to permanent caging of the vessels and its consequences, first of all late stent thrombosis (ST). Bioresorbable scaffolds (BRS) aim to overcome these issues. The results achieved in randomized controlled trials (RCT) by the firs...

  8. Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients.

    Science.gov (United States)

    Tada, Tomohisa; Byrne, Robert A; Simunovic, Iva; King, Lamin A; Cassese, Salvatore; Joner, Michael; Fusaro, Massimiliano; Schneider, Simon; Schulz, Stefanie; Ibrahim, Tareq; Ott, Ilka; Massberg, Steffen; Laugwitz, Karl-Ludwig; Kastrati, Adnan

    2013-12-01

    This study sought to compare the risk of stent thrombosis among patients treated with bare-metal stents (BMS), first-generation drug-eluting stents (G1-DES), and second-generation drug-eluting stents (G2-DES) for a period of 3 years. In patients undergoing coronary stenting, there is a scarcity of long-term follow-up data on cohorts large enough to compare rates of stent thrombosis across the stent generations. A total of 18,334 patients undergoing successful coronary stent implantation from 1998 to 2011 at 2 centers in Munich, Germany, were included in this study. Patients were stratified into 3 groups according to treatment with BMS, G1-DES, and G2-DES. The cumulative incidence of definite stent thrombosis at 3 years was 1.5% with BMS, 2.2% with G1-DES, and 1.0% with G2-DES. On multivariate analysis, G1-DES compared with BMS showed a significantly higher risk of stent thrombosis (odds ratio [OR]: 2.05; 95% confidence interval [CI]: 1.47 to 2.86; p stent thrombosis compared with BMS (OR: 0.82; 95% CI: 0.56 to 1.19; p = 0.30). Beyond 1 year, the risk of stent thrombosis was significantly increased with G1-DES compared with BMS (OR: 4.72; 95% CI: 2.01 to 11.1; p stenting, compared with BMS, there was a significant excess risk of stent thrombosis at 3 years with G1-DES, driven by an increased risk of stent thrombosis events beyond 1 year. G2-DES were associated with a similar risk of stent thrombosis compared with BMS. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated With Percutaneous Coronary Intervention: The Scandinavian Organization for Randomized Trials With Clinical Outcome IV (SORT OUT IV)

    DEFF Research Database (Denmark)

    Okkels Jensen, Lisette; Thayssen, Per; Hansen, Henrik Steen

    2012-01-01

    was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularization) parameters. The noninferiority criterion was a risk difference of 0.015. Intention-to-treat analyses were done at 9- and 18-month follow-ups. A total of 1390 patients were.......71-1.23). At the 9-month follow-up, the rate of definite stent thrombosis was higher in the sirolimus-eluting group (2 patients [0.1%] versus 9 patients [0.7%]; hazard ratio, 0.22; 95% confidence interval, 0.05-1.02). At the 18-month follow-up, this difference was sustained (3 patients [0.2%] versus 12 patients [0...

  10. Preparation and characterization of iron(III) {sup 99}Mo-molybdate(VI) gels for the assessment of {sup 99m}Tc elution performance

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Mahmoud; Fasih, Tharwat W.; El-Absy, Mohamed A. [Egyptian Atomic Energy Authority, Cairo (Egypt)

    2018-04-01

    New iron(III) {sup 99}Mo-molybdate(VI) gels (Fe{sup 99}Mo) of high Mo content were prepared by the precipitation/filtration method. {sup 99}Mo-MoO{sub 3} dissolved in NaOH was added to aqueous solutions of Fe(NO{sub 3}){sub 3} at Mo/Fe mole fractions ∝2.21 and 1.99 with continuous stirring at ambient room temperature. Two different Fe{sup 99}Mo were precipitated from the mixed solutions adjusted at pH 2 and 4.7. The amount of water of hydration increased with the increasing the gel settling time and pH of the mixed solution. The matrices were characterized by radiometric, XRD, SEM, XRF, FT-IR, TGA, and DTA measurements. Small chromatographic columns of 2.0 g Fe{sup 99}Mo containing ≥800 mg Mo tagged with 740 MBq {sup 99}Mo were eluted with 5 mL saline solution. Highly reproducible {sup 99m}Tc elution indices suitable for preparation of {sup 99}Mo/{sup 99m}Tc generators were achieved from generator supported with 0.5 g Al{sub 2}O{sub 3} filter. Elution performance of {sup 99m}Tc radionuclide was highly dependent on the gel structural properties.

  11. A SINGLE-COLUMN PROCEDURE ON BOND ELUT CERTIFY FOR SYSTEMATIC TOXICOLOGICAL ANALYSIS OF DRUGS IN PLASMA AND URINE

    NARCIS (Netherlands)

    CHEN, XH; WIJSBEEK, J; FRANKE, JP; DEZEEUW, RA

    A single-column solid-phase extraction procedure was developed for the screening of acidic, neutral, and basic drugs from plasma. The recoveries of all 25 tested drugs exceeded 82%. After the plasma had been diluted with phosphate buffer (pH 6.0), the drugs were extracted using a single Bond Elut

  12. Different elution modes and field programming in gravitational field-flow fractionation: Field programming using density and viscosity gradients

    Czech Academy of Sciences Publication Activity Database

    Plocková, Jana; Chmelík, Josef

    2006-01-01

    Roč. 1118, č. 2 (2006), s. 253-260 ISSN 0021-9673 R&D Projects: GA MZe QD1005 Institutional research plan: CEZ:AV0Z40310501 Keywords : gravitational field flow fractionation * focusing elution mode * carrier liquid density Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.554, year: 2006

  13. Ultraviolet light induces double-strand breaks in DNA of cultured human P3 cells as measured by neutral filter elution

    International Nuclear Information System (INIS)

    Peak, J.G.; Peak, M.J.

    1990-01-01

    Neutral filter elution at pH 7.2 and 9.6 was used to measure the induction of DNA lesions in human P3 teratocarcinoma cells by monochromatic 254-, 270-, 313-, 334-, 334-,365-, and 405-nm radiation and by 60 gamma rays. In this assay DNA double-strand breaks (dsb) increase the rate of elution of DNA from cell lysates on a filter. Yields of dsb as measured by this procedure were determined by using a calibration of the assay that correlates elution parameters with number of dsb caused by disintegration of 125 I incorporated into the DNA. Analysis of fluence responses obtained by using the calibrated assay indicated that the number of dsb induced per dalton of DNA as measured by this assay is proportional to the square of the fluence at all the energies of radiation studied, implying that the induction of these lesions may be a two-hit event. Analysis of the relative efficiencies for the induction of dsb by ultraviolet radiation, corrected for quantum efficiency, revealed a spectrum that coincided closely with that for the induction of single-strand breaks (ssb) in the same cells, having a close fit with the spectrum of nucleic acid in the UVC and UVB region below 313 nm, and a shoulder in the UVA region. It was calculated, however, that there may be too few ssb for dsb to result from randomly distributed closely opposed ssb. (author)

  14. A study on exposure dose from injection work and elution work for radiation workers and frequent workers in nuclear medicine

    International Nuclear Information System (INIS)

    Ju, Yong Jin; Chung, Woon Kwan; Dong, Kyung Rae; Choi, Eun Jin; Kwak, Jong Gil; Ryu, Jae Kwang

    2017-01-01

    Compared to other occupations, there is a greater risk of exposure to radiation due to the use of radioisotopes in nuclear medicine for diagnostic evaluations and therapy. To consider ways to reduce exposure dose for those in nuclear medicine involved in injection work and elution work among radiation workers as well as for sanitation workers and trainees among frequent workers an investigation into exposure dose and situational analysis from changes in yearly exposure dose evaluations, changes in work environment and changes in forms of inspection were conducted. Exposure dose measurements were taken by using EPD MK2 worn during working hours for one injection worker, one elution worker, two sanitation workers, and one trainee at a general hospital in the Seoul area for three days from July 18th to 20th 2016. Radiation from radioisotopes which are a part of nuclear medicine can significantly affect not only radiation workers who deal with radioisotopes directly but also frequency works as well. According to this study the annual dose limit for elution workers and injection workers were considered safe as the amount of exposure was not large enough to have a signifcant effect. The limits of this study consist in the duration of this study and the quantity of participants. Also there was a limitation of the measurement device involving accumulated exposure, where the EPD MK2 cannot check the changes in exposure according to a particular activity

  15. A study on exposure dose from injection work and elution work for radiation workers and frequent workers in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Yong Jin; Chung, Woon Kwan [Dept. of Nuclear Engineering, Chosun University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Choi, Eun Jin; Kwak, Jong Gil [Dept. of Public Health and Medicine, Dongshin University Graduate School, Naju (Korea, Republic of); Ryu, Jae Kwang [Dept. of Nuclear Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-03-15

    Compared to other occupations, there is a greater risk of exposure to radiation due to the use of radioisotopes in nuclear medicine for diagnostic evaluations and therapy. To consider ways to reduce exposure dose for those in nuclear medicine involved in injection work and elution work among radiation workers as well as for sanitation workers and trainees among frequent workers an investigation into exposure dose and situational analysis from changes in yearly exposure dose evaluations, changes in work environment and changes in forms of inspection were conducted. Exposure dose measurements were taken by using EPD MK2 worn during working hours for one injection worker, one elution worker, two sanitation workers, and one trainee at a general hospital in the Seoul area for three days from July 18th to 20th 2016. Radiation from radioisotopes which are a part of nuclear medicine can significantly affect not only radiation workers who deal with radioisotopes directly but also frequency works as well. According to this study the annual dose limit for elution workers and injection workers were considered safe as the amount of exposure was not large enough to have a signifcant effect. The limits of this study consist in the duration of this study and the quantity of participants. Also there was a limitation of the measurement device involving accumulated exposure, where the EPD MK2 cannot check the changes in exposure according to a particular activity.

  16. Patient-Centered Tablet Application for Improving Medication Adherence after a Drug-Eluting Stent.

    Science.gov (United States)

    Shah, Vicki; Dileep, Anandu; Dickens, Carolyn; Groo, Vicki; Welland, Betty; Field, Jerry; Baumann, Matthew; Flores, Jose D; Shroff, Adhir; Zhao, Zhongsheng; Yao, Yingwei; Wilkie, Diana J; Boyd, Andrew D

    2016-01-01

    This study's objective was to evaluate a patient-centered educational electronic tablet application, "My Interventional Drug-Eluting Stent Educational App" (MyIDEA) to see if there was an increase in patient knowledge about dual antiplatelet therapy (DAPT) and medication possession ratio (MPR) compared to treatment as usual. In a pilot project, 24 elderly (≥50 years old) research participants were recruited after a drug-eluting stent. Eleven were randomized to the control arm and 13 to the interventional arm. All the participants completed psychological and knowledge questionnaires. Adherence was assessed through MPR, which was calculated at 3 months for all participants who were scheduled for second and third follow-up visits. Relative to control, the interventional group had a 10% average increase in MPR. As compared to the interventional group, more patients in the control group had poor adherence (<80% MPR). The psychological data revealed a single imbalance in anxiety between the control and interventional groups. On average, interventional participants spent 21 min using MyIDEA. Consumer health informatics has enabled us to engage patients with their health data using novel methods. Consumer health technology needs to focus more on patient knowledge and engagement to improve long-term health. MyIDEA takes a unique approach in targeting DAPT from the onset. MyIDEA leverages patient-centered information with clinical care and the electronic health record highlighting the patients' role as a team member in their own health care. The patients think critically about adverse events and how to solve issues before leaving the hospital.

  17. Patient Centered Tablet Application for improving medication adherence after a Drug Eluting Stent

    Directory of Open Access Journals (Sweden)

    Vicki Shah

    2016-12-01

    Full Text Available Background/Aims: This study’s objective was to evaluate a patient-centered educational electronic tablet application, My Interventional Drug-Eluting Stent Educational App (MyIDEA to see if there was an increase in patient knowledge about dual antiplatelet therapy (DAPT and medication possession ratio (MPR compared to treatment as usual. Methods: In a pilot project, 24 elderly (≥50 years-old research participants were recruited after a Drug Eluting Stent. 11 were randomized to the control arm and 13 to the interventional arm. All participants completed psychological and knowledge questionnaires. Adherence was assessed through MPR, which was calculated at three months for all participants who were scheduled for a second and third follow-up visit.Results: Relative to control, the interventional group had a 10% average increase in MPR. As compared to the interventional group, more patients in the control group had poor adherence (<80% MPR. The psychological data revealed a single imbalance in anxiety between the control and interventional groups. On average interventional participants spent 21 minutes using MyIDEA. Discussion: Consumer health informatics has enabled us to engage patients with their health data using novel methods. Consumer health technology needs to focus more on patient knowledge and engagement to improve long term health. MyIDEA takes a unique approach in targeting DAPT from the onset.Conclusion: MyIDEA leverages patient centered information with clinical care and the electronic health record highlighting the patients’ role as a team member in their own healthcare. The patients think critically about adverse events and how to solve issues before leaving the hospital.

  18. Kultuuri elutööpreemiale esitati Pärtelpoeg, Sööt ja Tormis / Valner Valme, Tiit Tuumalu, Tiina Kolk

    Index Scriptorium Estoniae

    2010-01-01

    Riigi kultuuripreemiate komisjon tegi ettepaneku määrata miljonikroonine kultuuri elutööpreemia Leila Pärtelpojale, Andres Söödile ja Lea Tormisele. Lühidalt nende tegevusest. Lisaks antakse välja viis 150 000 kroonist preemiat. Loetletud 2009. aasta kultuuripreemiate laureaadid

  19. Detection of UVR-induced DNA damage in mouse epidermis in vivo using alkaline elution

    International Nuclear Information System (INIS)

    Kinley, J.S.; Moan, J.; Brunborg, G.

    1995-01-01

    Alkaline elution has been used to detect ultraviolet radiation (UVR)-induced DNA damage in the epidermis of C3H/Tif hr/hr mice. This technique detects DNA damage in the form of single-strand breaks and alkali-labile sites (SSB) formed directly by UVA (320-400 nm) or indirectly by UVB (280-320 nm). The latter induces DNA damage such as cyclobutane pyrimidine dimers and pyrimidine-pyrimidone (6-4)-photoproducts, which are then converted into transient SSB by cellular endonucleases, during nucleotide excision repair (NER). (Author)

  20. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease

    DEFF Research Database (Denmark)

    Onuma, Yoshinobu; Dudek, Dariusz; Thuesen, Leif

    2013-01-01

    This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California).......This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California)....

  1. Research Article. The Influence of Some Parameters on Chiral Separation of Ibuprofen by High-Performance Liquid Chromatography and Capillary Electrophoresis

    Directory of Open Access Journals (Sweden)

    Balint Alina

    2017-03-01

    Full Text Available Objective: The aim of the study was to compare the influence of mobile phase composition and temperature on chiral separation of racemic ibuprofen by capillary electrophoresis and high performance liquid chromatography with UV detection. Materials and methods: Racemic ibuprofen was analysed on a chiral OVM column with an HPLC system 1100 Agilent Technologies, under isocratic elution, by using potassium dihydrogen phosphate 20 mM and ethanol in mobile phase. The flow rate was set at 1 mL/min, UV detector at 220 nm and different column temperatures were tested. For electrophoresis separation an Agilent CE G1600AX Capillary Electrophoresis System system, with UV detection, was used. The electrophoresis analysis was performed at different pH values and temperatures, with phosphate buffer 25 mM and methyl-β-cyclodextrin as chiral selector. Results: The chromatograhic analysis reveals a high influence of mobile phase pH on ibuprofen enantiomers separation. An elution with a mixture of potassium dihydrogen phosphate 20 mM pH=3 and ethanol, at 25°C, allowed enantiomers separation with good resolution in less than 8 min. Conclusions: The proposed HPLC method proved suitable for the separation of ibuprofen enantiomers with a good resolution, but the capillary electrophoresis tested parameters did not allow chiral discrimination.

  2. A chromatographic objective function to characterise chromatograms with unknown compounds or without standards available.

    Science.gov (United States)

    Alvarez-Segura, T; Gómez-Díaz, A; Ortiz-Bolsico, C; Torres-Lapasió, J R; García-Alvarez-Coque, M C

    2015-08-28

    Getting useful chemical information from samples containing many compounds is still a challenge to analysts in liquid chromatography. The highest complexity corresponds to samples for which there is no prior knowledge about their chemical composition. Computer-based methodologies are currently considered as the most efficient tools to optimise the chromatographic resolution, and further finding the optimal separation conditions. However, most chromatographic objective functions (COFs) described in the literature to measure the resolution are based on mathematical models fitted with the information obtained from standards, and cannot be applied to samples with unknown compounds. In this work, a new COF based on the automatic measurement of the protruding part of the chromatographic peaks (or peak prominences) that indicates the number of perceptible peaks and global resolution, without the need of standards, is developed. The proposed COF was found satisfactory with regard to the peak purity criterion when applied to artificial peaks and simulated chromatograms of mixtures built using the information of standards. The approach was applied to mixtures of drugs containing unknown impurities and degradation products and to extracts of medicinal herbs, eluted with acetonitrile-water mixtures using isocratic and gradient elution. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    Science.gov (United States)

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. High Efficiency Robust Open Tubular Capillary Electrochromatography Column for the Separation of Peptides

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Faiz; Cheong, Won Jo [Inha University, Incheon (Korea, Republic of)

    2016-08-15

    In this study, the carefully designed tri-component copolymer layer was fabricated onto the inner surface of a pretreated silica capillary (52 cm effective length, 50 μm id). The initiator moieties were incorporated onto the capillary inner surface by reaction with 4-chloromehtylphenyl isocyanate followed by sodium diethyl dithiocarbamate. Next, RAFT copolymerization was held upon the initiator moieties and a thin polymer film was made. The observed peak capacity was, of course, lower than those of the state-of-the art gradient HPLC systems. The UPLC system operated in the long gradient elution mode with a long narrow column of sub-3 μm packed particles could achieve the impressive high peak capacity of ca. 1000. On the other hand, a system with a 20 cm column of 0.8 μm particles could achieve a peak capacity of 220 (comparable to our result) under a pressure of 20 000 psi in a gradient time of 20 min. It should be noted that the operational conditions of this study has been optimized to obtain the best column separation efficiency. It was also operated in the isocratic elution mode. A better peak capacity is expected if the operational conditions are tuned to the optimum peak capacity.

  5. Simultaneous Liquid Chromatographic Determination of 10 Ultra-Violet Filters in Sunscreens.

    Science.gov (United States)

    Wharton, Mary; Geary, Michael; O'Connor, Niamh; Curtin, Laura; Ketcher, Krystal

    2015-09-01

    A rapid HPLC method was developed for the simultaneous determination of 10 UV filters found in sunscreen. The following UV filters were analyzed in this method; 2-phenylbenzimidazole-5-sulfonic acid, benzophenone-3, isoamyl p-methoxycinnamate, 4-methylbenzylidene camphor, octocrylene, ethylhexyl dimethyl 4-aminobenzoic acid, ethylhexyl methoxycinnamate, butyl methoxydibenzoylmethane, ethylhexyl salicylate and homosalate. The method was developed on two columns; a Thermo Hypersil C18 BDS, 3 µm column (4.6 × 100 mm) and a Chromolith RP-18e Monolithic column (4.6 × 100 mm). The same mobile phase of ethanol and 1% acetic acid (70:30, v/v) was employed for both columns. The separation of the 10 UV filters was carried out successfully on both columns; the optimal resolution was obtained on the Thermo Scientific Hypersil column in a time frame of 7 min. An isocratic elution utilizing ethanol and acetic acid (70:30, v/v) at a temperature of 35°C was employed. The method was applied to a number of commercial samples of sunscreen and lotions and was validated according to International Conference on Harmonisation guidelines for selectivity, linearity, accuracy, precision and robustness. A comparison of the performances of both columns was also carried out. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Zotarolimus-eluting Resolute Integrity versus everolimus-eluting Xience Xpedition stents in the management of very long (>30 mm) de novo coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Patra, Soumya, E-mail: dr_soumyapatra@rediffmail.com; Chakraborty, Rabindra Nath; Pande, Arindam; Banerjee, Suvro; Jena, Manabhanjan; Mandal, Prakash Chandra; De, Swapan Kumar; Khan, Aftab; Das, Sankha Suvro; Ghosh, Debashish; Nag, Raja

    2017-04-15

    Background: Procedural and clinical outcomes in patients with very long (>30 mm) coronary lesions who underwent stent-based percutaneous coronary interventions are still unfavorable. Therefore, we compared the relative efficacy and safety of resolute zotarolimus-eluting stents (R-ZES) and Xpedition everolimus-eluting stents (X-EES) for patients with de novo very long coronary lesions. Methods: This comparative single-centre, retrospective study compared long R-ZES and X-EES in consecutive patients admitted with very long (≥30 mm) native ACC/AHA type C coronary lesions in 2014. All patients were followed up clinically at 1, 3, 6 and 12 months. In this study, only symptom-driven angiogram was advised. The study end point was to evaluate immediate procedural success and one-year rate of target lesion failure (TLF), which is a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization (TLR). Results: Total number of patients enrolled in this study was 185 (R-ZES = 107; X-EES = 78). The baseline characteristics and post procedural success rate were similar between R-ZES and X-EES groups, including the post stenting lesion lengths (36.6 ± 1.92 mm vs 40.71 ± 6.175 mm, P = 0.09). At 12-month follow-up, there were no significant between-group differences in the rate of adverse clinical events (death, myocardial infarction, stent thrombosis, target lesion revascularization, and composite outcomes). Procedural success was achieved in 94% in R-ZES group and 93% in X-EES group (P = 0.24). The incidence of TLF was 5% in R-ZES and 4% in X-EES groups (HR-1.25; 95% CI-0.86-5.6; P = 0.19). Conclusion: Patients with de novo long coronary artery disease, R-ZES implantation showed similar clinical outcome as compared with X-EES implantation. - Highlights: • This is the first study comparing between R-ZES (Resolute Integrity) and X-EES (Xience Xpedition) used in PCI for long coronary artery disease. Here, single stent length of more than 30

  7. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    Science.gov (United States)

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  8. Biodegradable drug-eluting nanofiber-enveloped implants for sustained release of high bactericidal concentrations of vancomycin and ceftazidime: in vitro and in vivo studies

    Directory of Open Access Journals (Sweden)

    Hsu YH

    2014-09-01

    Full Text Available Yung-Heng Hsu,1,2 Dave Wei-Chih Chen,1 Chun-Der Tai,3 Ying-Chao Chou,1,2 Shih-Jung Liu,2 Steve Wen-Neng Ueng,1 Err-Cheng Chan4 1Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Guishan Township, 2Department of Mechanical Engineering, Chang Gung University, Guishan Township, 3Graduate Institute of Medical Mechatronics, Chang Gung University, Guishan Township, 4School of Medical Technology, Chang Gung University, Guishan Township, Taiwan Abstract: We developed biodegradable drug-eluting nanofiber-enveloped implants that provided sustained release of vancomycin and ceftazidime. To prepare the biodegradable nanofibrous membranes, poly(D,L-lactide-co-glycolide and the antibiotics were first dissolved in 1,1,1,3,3,3-hexafluoro-2-propanol. They were electrospun into biodegradable drug-eluting membranes, which were then enveloped on the surface of stainless plates. An elution method and a high-performance liquid chromatography assay were employed to characterize the in vivo and in vitro release rates of the antibiotics from the nanofiber-enveloped plates. The results showed that the biodegradable nanofiber-enveloped plates released high concentrations of vancomycin and ceftazidime (well above the minimum inhibitory concentration for more than 3 and 8 weeks in vitro and in vivo, respectively. A bacterial inhibition test was carried out to determine the relative activity of the released antibiotics. The bioactivity ranged from 25% to 100%. In addition, the serum creatinine level remained within the normal range, suggesting that the high vancomycin concentration did not affect renal function. By adopting the electrospinning technique, we will be able to manufacture biodegradable drug-eluting implants for the long-term drug delivery of different antibiotics. Keywords: biodegradable nanofiber-enveloped plates, electrospinning, antibiotics, release characteristics

  9. Mobile phase effects on the retention on polar columns with special attention to the dual hydrophilic interaction-reversed-phase liquid chromatography mechanism, a review.

    Science.gov (United States)

    Jandera, Pavel; Hájek, Tomáš

    2018-01-01

    Hydrophilic interaction liquid chromatography on polar columns in aqueous-organic mobile phases has become increasingly popular for the separation of many biologically important compounds in chemical, environmental, food, toxicological, and other samples. In spite of many new applications appearing in literature, the retention mechanism is still controversial. This review addresses recent progress in understanding of the retention models in hydrophilic interaction liquid chromatography. The main attention is focused on the role of water, both adsorbed by the column and contained in the bulk mobile phase. Further, the theoretical retention models in the isocratic and gradient elution modes are discussed. The dual hydrophilic interaction liquid chromatography reversed-phase retention mechanism on polar columns is treated in detail, especially with respect to the practical use in one- and two-dimensional liquid chromatography separations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Analysis of penicillin G in milk by liquid chromatography.

    Science.gov (United States)

    Boison, J O; Keng, L J; MacNeil, J D

    1994-01-01

    A liquid chromatographic (LC) method that was previously developed for penicillin G residues in animal tissues has been adapted to milk and milk products. After protein precipitation with sodium tungstate, samples are applied to a C18 solid-phase extraction cartridge, from which penicillin is eluted, derivatized with 1,2,4-triazole-mercuric chloride solution, and analyzed by isocratic liquid chromatography (LC) on a C18 column with UV detection at 325 nm. Quantitation is done with reference to penicillin V as an internal standard. Penicillin G recoveries were determined to be > 70% on standards fortified at 3-60 ppb. Accuracy approached 100% using the penicillin V internal standard. The detection limit for penicillin G residues was 3 ppb in fluid milk. Samples may be confirmed by thermospray/LC at concentrations approaching the detection limit of the UV method.

  11. A Novel HPLC Method for the Concurrent Analysis and Quantitation of Seven Water-Soluble Vitamins in Biological Fluids (Plasma and Urine: A Validation Study and Application

    Directory of Open Access Journals (Sweden)

    Margherita Grotzkyj Giorgi

    2012-01-01

    Full Text Available An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12 in biological matrices (plasma and urine. Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males. Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.

  12. Elution behavior of N-heterocyclic derivatives of mixed ruthenium(II)-sulfoxide complexes in reversed-phase high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Toma, H.E.; Silva, D.O.

    1991-01-01

    The elution behaviour of a series of dichlorobis-(dimethylsulfoxide)bis(N-heterocyclic) ruthenium(II) complexes has been investigated using reversed-phase HPLC. Similar trends as those displayed by the free N-heterocyclic bases have been observed for the complexes, essentially reflecting the hydrophobic properties of the aromatic ligands. (orig.)

  13. The indicating FTA elute cartridge a solid sample carrier to detect high-risk HPV and high-grade cervical lesions

    NARCIS (Netherlands)

    Bie, R.P. de; Schmeink, C.E.; Bakkers, J.M.J.E.; Snijders, P.J.L.M.; Quint, W.G.V.; Massuger, L.F.A.G.; Bekkers, R.L.M.; Melchers, W.J.G.

    2011-01-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were

  14. Second generation drug-eluting stents versus bare-metal stents for percutaneous coronary intervention of the proximal left anterior descending artery

    DEFF Research Database (Denmark)

    Mangione, Fernanda Marinho; Biering-Sørensen, Tor; Nochioka, Kotaro

    2017-01-01

    OBJECTIVES: To compare mid-term outcomes between patients undergoing proximal left anterior descending artery (LAD) percutaneous coronary intervention (PCI) with second generation drug-eluting stent (DES) or bare-metal stent (BMS). BACKGROUND: PCI with BMS and first-generation DES have shown to b...

  15. 125I-induced DNA double strand breaks: use in calibration of the neutral filter elution technique and comparison with X-ray induced breaks

    International Nuclear Information System (INIS)

    Radford, I.R.; Hodgson, G.S.

    1985-01-01

    The neutral filter elution assay, for measurement of DNA double strand breakage, has been calibrated using mouse L cells and Chinese hamster V79 cells labelled with [ 125 I]dUrd and then held at liquid nitrogen temperature to accumulate decays. The basis of the calibration is the observation that each 125 I decay, occurring in DNA, produces a DNA double strand break. Linear relationships between 125 I decays per cell and lethal lesions per cell (minus natural logarithm survival) and the level of elution, were found. Using the calibration data, it was calculated that the yield of DNA double strand breaks after X-irradiation of both cell types was from 6 to 9 x 10 -12 DNA double strand breaks per Gy per dalton of DNA, for doses greater than 6 Gy. Neutral filter elution and survival data for X-irradiated and 125 I-labelled cells suggested that the relationships between lethal lesions and DNA double strand breakage were significantly different for both cell types. An attempt was made to study the repair kinetics for 125 I-induced DNA double strand breaks, but was frustrated by the rapid DNA degradation which occurs in cells that have been killed by the freezing-thawing process. (author)

  16. Long-term prognostic value of risk scores after drug-eluting stent implantation for unprotected left main coronary artery: A pooled analysis of the ISAR-LEFT-MAIN and ISAR-LEFT-MAIN 2 randomized clinical trials.

    Science.gov (United States)

    Xhepa, Erion; Tada, Tomohisa; Kufner, Sebastian; Ndrepepa, Gjin; Byrne, Robert A; Kreutzer, Johanna; Ibrahim, Tareq; Tiroch, Klaus; Valgimigli, Marco; Tölg, Ralf; Cassese, Salvatore; Fusaro, Massimiliano; Schunkert, Heribert; Laugwitz, Karl L; Mehilli, Julinda; Kastrati, Adnan

    2017-01-01

    To evaluate the long-term prognostic value of risk scores in the setting of drug-eluting stent (DES) implantation for uLMCA. Data on the prognostic value of novel risk scores developed to select the most appropriate revascularization strategy in patients undergoing DES implantation for uLMCA disease are relatively limited. The study represents a patient-level pooled analysis of the ISAR-LEFT-MAIN (607 patients randomized to paclitaxel-eluting or sirolimus-eluting stents) and the ISAR-LEFT-MAIN-2 (650 patients randomized to everolimus-eluting or zotarolimus-eluting stents) randomized trials. The Syntax Score (SxScore) as well the Syntax Score II (SS-II), the EuroSCORE and the Global Risk Classification (GRC) were calculated. The primary outcome was all-cause mortality. At a mean follow-up of 3 years there were 160 deaths (12.7%). The death-incidence was significantly higher in the upper tertiles than in the intermediate or lower ones for all risk scores (log-rank test P risk scores were able to stratify the mortality risk at long-term follow-up. EuroSCORE was the only risk score that significantly improved the discriminatory power of a multivariable model to predict long-term mortality. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention

    OpenAIRE

    Baschet, Louise; Bourguignon, Sandrine; Marque, S?bastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    Objective To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. Methods A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117?762 patient-years with 76 randomised trials. The main effectiveness criterion was major c...

  18. Efficacy and compatibility with mass spectrometry of methods for elution of proteins from sodium dodecyl sulfate-polyacrylamide gels and polyvinyldifluoride membranes

    DEFF Research Database (Denmark)

    Jørgensen, C.S.; Jagd, M.; Sørensen, B.K.

    2004-01-01

    projects. As a result of this, methods for postelectrophoretic protein characterization are of Great interest as exemplified by in situ protease digestion combined with mass spectrometry (MS), which is the method of choice for identification of proteins. In this study we have developed and compared methods...... for recovering intact proteins from polyacrylamide gels and electroblotting membranes to define efficient methods compatible with MS. These methods complement in situ digestion protocols and allow determination of the molecular mass of whole proteins separated by SDS-PAGE. Passive elution of proteins from SDS......-PAGE gels was efficient only in the presence of SDS, whereas electroelution was achieved using butTers without SDS. Surface-enhanced laser desorption/ionization MS (SELDI-MS) analysis of proteins eluted in the presence of SIDS was possible using ion exchange ProteinChip arrays for concentration of sample...

  19. Sequential Elution of Essential Oil Constituents during Steam Distillation of Hops (Humulus lupulus L.) and Influence on Oil Yield and Antimicrobial Activity.

    Science.gov (United States)

    Jeliazkova, Ekaterina; Zheljazkov, Valtcho D; Kačániova, Miroslava; Astatkie, Tess; Tekwani, Babu L

    2018-06-07

    The profile and bioactivity of hops (Humulus lupulus L.) essential oil, a complex natural product extracted from cones via steam distillation, depends on genetic and environmental factors, and may also depend on extraction process. We hypothesized that compound mixtures eluted sequentially and captured at different timeframes during the steam distillation process of whole hop cones would have differential chemical and bioactivity profiles. The essential oil was collected sequentially at 8 distillation time (DT) intervals: 0-2, 2-5, 5-10, 10-30, 30-60, 60-120, 120-180, and 180-240 min. The control was a 4-h non-interrupted distillation. Nonlinear regression models described the DT and essential oil compounds relationship. Fractions yielded 0.035 to 0.313% essential oil, while control yielded 1.47%. The oil eluted during the first hour was 83.2%, 9.6% during the second hour, and only 7.2% during the second half of the distillation. Essential oil (EO) fractions had different chemical profile. Monoterpenes were eluted early, while sequiterpenes were eluted late. Myrcene and linalool were the highest in 0-2 min fraction, β-caryophyllene, β-copaene, β-farnesene, and α-humulene were highest in fractions from middle of distillation, whereas α- bergamotene, γ-muurolene, β- and α-selinene, γ- and δ-cadinene, caryophyllene oxide, humulne epoxide II, τ-cadinol, and 6-pentadecen-2-one were highest in 120-180 or 180-240 min fractions. The Gram-negative Escherichia coli was strongly inhibited by essential oil fractions from 2-5 min and 10-30 min, followed by oil fraction from 0-2 min. The strongest inhibition activity against Gram-negative Yersinia enterocolitica, and Gram-positive Clostridium perfringens, Enterococcus faecalis, and Staphylococcus aureus subs. aureus was observed with the control essential oil. This is the first study to describe significant activity of hops essential oils against Trypanosoma brucei, a parasitic protozoan that causes African

  20. Evaluation of XIENCE V everolimus-eluting and Taxus Express2 paclitaxel-eluting coronary stents in patients with jailed side branches from the SPIRIT IV trial at 2 years.

    Science.gov (United States)

    Forrest, John K; Lansky, Alexandra J; Meller, Stephanie M; Hou, Liming; Sood, Poornima; Applegate, Robert J; Wang, John C; Skelding, Kimberly A; Shah, Aakar; Kereiakes, Dean J; Sudhir, Krishnankutty; Cristea, Ecaterina; Yaqub, Manejeh; Stone, Gregg W

    2013-06-01

    The aim of this study was to determine whether patients from the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions (SPIRIT) IV trial who underwent percutaneous coronary intervention, who had target lesions with jailed side branches, had improved clinical outcomes when treated with the XIENCE V versus Taxus Express(2) drug-eluting stent. In the SPIRIT III randomized trial, patients with target lesions with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had lower 2-year rates of major adverse cardiac events. The SPIRIT IV trial represents a larger more diverse patient population compared with SPIRIT III. In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, 3,687 patients who underwent coronary stenting with up to 3 de novo native coronary artery lesions were randomized 2:1 to receive XIENCE V versus Taxus Express(2) stents. Two-year clinical outcomes of patients with or without jailed side branches after stenting were compared. A jailed side branch was defined as any side branch >1.0 mm in diameter within the target segment being stented, excluding bifurcations deemed to require treatment. Of the 3,687 patients in SPIRIT IV, a total of 1,426 had side branches that were jailed during angioplasty of the target lesion. Patients with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had significantly lower 2-year rates of target lesion failure (6.5% vs 11.9%, p = 0.001), major adverse cardiac events (6.6% vs 12.2%, p = 0.0008), ischemia-driven target vessel revascularization (4.1% vs 7.9%, p = 0.004), and stent thrombosis (0.6% vs 2.8%, p = 0.001). In conclusion, patients with jailed side branches after stenting with XIENCE V compared to Taxus Express(2) devices had superior clinical outcomes at 2 years in the large-scale randomized SPIRIT IV trial. Copyright © 2013 Elsevier Inc. All

  1. Drug-eluting Ti wires with titania nanotube arrays for bone fixation and reduced bone infection

    Science.gov (United States)

    Gulati, Karan; Aw, Moom Sinn; Losic, Dusan

    2011-10-01

    Current bone fixation technology which uses stainless steel wires known as Kirschner wires for fracture fixing often causes infection and reduced skeletal load resulting in implant failure. Creating new wires with drug-eluting properties to locally deliver drugs is an appealing approach to address some of these problems. This study presents the use of titanium [Ti] wires with titania nanotube [TNT] arrays formed with a drug delivery capability to design alternative bone fixation tools for orthopaedic applications. A titania layer with an array of nanotube structures was synthesised on the surface of a Ti wire by electrochemical anodisation and loaded with antibiotic (gentamicin) used as a model of bone anti-bacterial drug. Successful fabrication of TNT structures with pore diameters of approximately 170 nm and length of 70 μm is demonstrated for the first time in the form of wires. The drug release characteristics of TNT-Ti wires were evaluated, showing a two-phase release, with a burst release (37%) and a slow release with zero-order kinetics over 11 days. These results confirmed our system's ability to be applied as a drug-eluting tool for orthopaedic applications. The established biocompatibility of TNT structures, closer modulus of elasticity to natural bones and possible inclusion of desired drugs, proteins or growth factors make this system a promising alternative to replace conventional bone implants to prevent bone infection and to be used for targeted treatment of bone cancer, osteomyelitis and other orthopaedic diseases.

  2. Analysis of co-eluted isomers of high-molecular weight polycyclic aromatic hydrocarbons in high performance liquid chromatography fractions via solid-phase nanoextraction and time-resolved Shpol'skii spectroscopy.

    Science.gov (United States)

    Wilson, Walter B; Campiglia, Andres D

    2011-09-28

    We present an accurate method for the determination of isomers of high-molecular weight polycyclic aromatic hydrocarbons co-eluted in HPLC fractions. The feasibility of this approach is demonstrated with two isomers of molecular weight 302 with identical mass fragmentation patterns, namely dibenzo[a,i]pyrene and naphtho[2,3-a]pyrene. Qualitative and quantitative analysis is carried out via laser-excited time-resolved Shpol'skii spectroscopy at liquid helium temperature. Unambiguous identification of co-eluted isomers is based on their characteristic 4.2 K line-narrowed spectra in n-octane as well as their fluorescence lifetimes. Pre-concentration of HPLC fractions prior to spectroscopic analysis is performed with the aid of gold nanoparticles via an environmentally friendly procedure. In addition to the two co-eluted isomers, the analytical figures of merit of the entire procedure were evaluated with dibenzo[a,l]pyrene, dibenzo[a,h]pyrene and dibenzo[a,e]pyrene. The analytical recoveries from drinking water samples varied between 98.2±5.5 (dibenzo[a,l]pyrene) and 102.7±3.2% (dibenzo[a,i]pyrene). The limits of detection ranged from 51.1 ng L(-1) (naphtho[2,3-a]pyrene) to 154 ng L(-1) (dibenzo[a,e]pyrene). The excellent analytical figures of merit associated to its HPLC compatibility makes this approach an attractive alternative for the analysis of co-eluted isomers with identical mass spectra. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) trials.

    Science.gov (United States)

    Sabaté, Manel; Räber, Lorenz; Heg, Dik; Brugaletta, Salvatore; Kelbaek, Henning; Cequier, Angel; Ostojic, Miodrag; Iñiguez, Andrés; Tüller, David; Serra, Antonio; Baumbach, Andreas; von Birgelen, Clemens; Hernandez-Antolin, Rosana; Roffi, Marco; Mainar, Vicente; Valgimigli, Marco; Serruys, Patrick W; Jüni, Peter; Windecker, Stephan

    2014-01-01

    This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up. Copyright © 2014 American

  4. Studies on {sup 99}Mo-{sup 99m}Tc adsorption and elution behaviors using the inorganic sorbent ceric tungstate and conventional organic resins

    Energy Technology Data Exchange (ETDEWEB)

    El-Sweify, Fatma H.; Fattah, Alaa El-Din A. Abdel; Aly, Shorouk M.; Ghamry, Mohamed A. [Atomic Energy Authority, Cairo (Egypt). Hot Laboratories Center; El-Sheikh, Ragaa [Zagazig Univ. (Egypt). Chemistry Dept.

    2017-09-01

    Adsorption behavior of {sup 99}Mo(VI) and {sup 99m}Tc(VII) was studied on ceric tungstate (CeW) and compared with the adsorption on the conventional cation and anion exchangers Dowex-50X8 and AG-2X8, respectively. The studies were carried out under static and dynamic conditions. The effect of contact time and pH on the adsorption was investigated under static conditions. High K{sub d}-values for sorption of {sup 99}Mo(VI) on (CeW) were obtained over the investigated pH range. {sup 99m}Tc was adsorbed with much lower K{sub d}-values. The K{sub d}-values were pH dependent. K{sub d}-values of {sup 99}Mo-adsorption on AG-2X8 were lower than those on (CeW) and vice versa for {sup 99m}Tc. Ionic species of both elements were not adsorbed on Dowex-50X8, indicating the absence of cationic species and the adsorption of both elements on AG-2X8 and (CeW) as anionic species. The loading and elution behaviors of {sup 99}Mo and {sup 99m}Tc on (CeW) were studied using different eluents. {sup 99}Mo remained strongly adsorbed under all conditions whereas {sup 99m}Tc was easily eluted. Adsorption of some fission products, i.e. {sup 95}Zr(IV) and {sup 95}Nb(V), in addition to {sup 123m}Te(IV) and {sup 75}Se(IV), as representatives of their corresponding fission product isotopes, as well as {sup 181}Hf, as probable radioactive contaminant was also studied. Solutions of the ionic species of those metals were loaded in mixtures together with {sup 99}Mo on (CeW) columns. Strong adsorption of those ionic species and {sup 99}Mo on (CeW) was found whereas {sup 99m}Tc was easily eluted. Different eluents were investigated for eluting {sup 99m}Tc from {sup 99}Mo-adsorbed on (CeW).

  5. The effect of stent coating on stent deliverability: direct randomised comparison of drug eluting and bare metal stents using the same stent platform.

    Science.gov (United States)

    Siminiak, Tomasz; Link, Rafał; Wołoszyn, Maciej; Kałmucki, Piotr; Baszko, Artur

    2012-01-01

    There is certain experimental and clinical evidence indicating that the covering of bare metal stents (BMS) with drug eluting polymers to produce drug eluting stents (DES) results in increased stent stiffness and modifies the mechanical properties of the stent platform. In addition, it has been speculated that the mechanical performance of DES, compared to BMS, may be related to the type of polymer used to cover stents. We aimed at evaluating the deliverability of DES with a lactate based biodegradable polymer and BMS in patients with stable coronary artery disease in a prospective randomised study. One hundred eleven consecutive patients (age: 36-77, mean 58.8 years) scheduled for routine angioplasty due to stable coronary disease were randomised to receive BMS (Chopin II(TM), Balton, Poland) or paclitaxel eluting stent (Chopin Luc(TM), Balton, Poland) using the same metal platform. Only patients scheduled for angioplasty using the direct implantation technique of a single stent were randomised. The exclusion criteria included patients 〉 80 years, multivessel disease and reference diameter of the target vessel 〉 3.5 mm. In the BMS group (n = 55; 35 males and 20 females), the mean diameter of implanted stents was 3.09 ± 0.40 and the mean length was 11.37 ± 2.80, whereas in the DES group (n = 56; 34 males and 22 females) the mean stent sizes were 3.02 ± 0.34 and 17.90 ± 7.38 mm, respectively (p 〉 0.05 for length). The groups did not significantly differ regarding the frequency of stent implantation to particular coronary vessels. The direct stenting technique was attempted and failed, leading to the stents' implantation after predilatation in five patients in the BMS group and six patients in the DES group. Failure of stent implantation and subsequent implantation of another stent type was observed in no BMS patients and in one DES patient (NS). Although stent covering with lactate based drug eluting polymer may increase its stiffness, it does not affect

  6. Characterization of polypropylene–polyethylene blends by temperature rising elution and crystallization analysis fractionation

    Science.gov (United States)

    del Hierro, Pilar

    2010-01-01

    The introduction of single-site catalysts in the polyolefins industry opens new routes to design resins with improved performance through multicatalyst-multireactor processes. Physical combination of various polyolefin types in a secondary extrusion process is also a common practice to achieve new products with improved properties. The new resins have complex structures, especially in terms of composition distribution, and their characterization is not always an easy task. Techniques like temperature rising elution fractionation (TREF) or crystallization analysis fractionation (CRYSTAF) are currently used to characterize the composition distribution of these resins. It has been shown that certain combinations of polyolefins may result in equivocal results if only TREF or CRYSTAF is used separately for their characterization. PMID:20730530

  7. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.

    Science.gov (United States)

    Poerner, Tudor C; Otto, Sylvia; Gassdorf, Johannes; Nitsche, Kristina; Janiak, Florian; Scheller, Bruno; Goebel, Björn; Jung, Christian; Figulla, Hans R

    2014-12-01

    In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64±9.65% in BMS+DEB versus 4.93±9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7±7.8 versus 11.0±5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8±11.9 versus 16.9±10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5±13.8% versus 36.8±15.6%; P=0.409) was found. Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up. http://www.clinicaltrials.gov. Unique identifier: NCT01056744. © 2014 American Heart Association, Inc.

  8. The Relationship Between Neutrophil–Lymphocyte Ratio and Primary Patency of Percutaneous Transluminal Angioplasty in Hemodialysis Arteriovenous Fistula Stenosis When Using Conventional and Drug-Eluting Balloons

    Energy Technology Data Exchange (ETDEWEB)

    Çildağ, Mehmet Burak, E-mail: mbcildag@yahoo.com [Adnan Menderes University, Department of Diagnostic and Interventional Radiology (Turkey); Çildağ, Songül, E-mail: songulcildag@yahoo.com [Adnan Menderes University, Department of Immunology and Allergy (Turkey); Köseoğlu, Ömer Faruk Kutsi, E-mail: kutsikoseoglu@yahoo.com [Adnan Menderes University, Department of Diagnostic and Interventional Radiology (Turkey)

    2016-12-15

    ObjectiveThe aim of this study is to investigate the potential association of neutrophil–lymphocyte ratio (NLR) between primary patency of percutaneous transluminal angioplasty (PTA) in hemodialysis arteriovenous fistula stenosis and type (Conventional and Drug-Eluting) of balloons used in PTA.Material-MethodThis retrospective study consists of 78 patients with significant arteriovenous fistulas stenosis who were treated with PTA by using Drug-Eluting Balloon (DEB) (n = 29) or Conventional Balloon (CB) (n = 49). NLR was calculated from preinterventional blood samples. All patients were classified into two groups. Group A; primary patency <12 months (43/78), Group B; primary patency ≥12 months (35/78). Cox regression analysis and Kaplan–Meier method were used to determine respectively independent factors affecting the primary patency and to compare the primary patency for the two balloon types.ResultsNLR ratio and balloon type of the two groups were significantly different (p = 0.002, p = 0.010). The cut-off value of NLR was 3.18 for determination of primary patency, with sensitivity of 81.4 % and specificity of 51.4 %. Primary patency rates between PTA with DEB and CB displayed statistically significant differences (p < 0.05). The cut-off value was 3.28 for determination of 12-month primary patency with the conventional balloon group; sensitivity was 81.8 % and specificity was 81.3 %. There was no statistical relation between NLR levels and the drug-eluting balloon group in 12-month primary patency (p = 0.927).ConclusionIncreased level of NLR may be a risk factor in the development of early AVF restenosis after successful PTA. Preferring Drug-Eluting Balloon at an increased level of NLR can be beneficial to prolong patency.

  9. Brachytherapy Application With In Situ Dose Painting Administered by Gold Nanoparticle Eluters

    International Nuclear Information System (INIS)

    Sinha, Neeharika; Cifter, Gizem; Sajo, Erno; Kumar, Rajiv; Sridhar, Srinivas; Nguyen, Paul L.; Cormack, Robert A.; Makrigiorgos, G. Mike; Ngwa, Wilfred

    2015-01-01

    Purpose: Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A new strategy proposed for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in situ release after implantation. This in silico study investigated the intratumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials: An experimentally determined intratumoral diffusion coefficient (D) for 10-nm nanoparticles was used to estimate D for other sizes by using the Stokes-Einstein equation. GNP concentration profiles, obtained using D, were then used to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel, using dose painting-by-numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation was carried out as a function of GNP size for the clinically applicable low-dose-rate brachytherapy sources iodine-125 (I-125), palladium-103 (Pd-103), and cesium-131 (Cs-131). Results: Results showed that dose enhancement to tumor voxels and subvolumes during brachytherapy can be customized by varying the size of GNP released or eluted from the GBS. For example, using a concentration of 7 mg/g GNP, significant DEF (>20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNP sizes of 2, 5, 10, 20, 30, and 50 nm and for 80 nm when treating with I-125. Conclusions: Analyses showed that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. These findings provide a useful reference for further work toward development of potential new brachytherapy application

  10. Brachytherapy Application With In Situ Dose Painting Administered by Gold Nanoparticle Eluters

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Neeharika [Department of Sciences, Wentworth Institute of Technology, Boston, Massachusetts (United States); Cifter, Gizem [Department of Physics and Applied Physics, University of Massachusetts, Lowell, Massachusetts (United States); Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Sajo, Erno [Department of Physics and Applied Physics, University of Massachusetts, Lowell, Massachusetts (United States); Kumar, Rajiv; Sridhar, Srinivas [Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Electronic Materials Research Institute and Department of Physics, Northeastern University, Boston, Massachusetts (United States); Nguyen, Paul L.; Cormack, Robert A.; Makrigiorgos, G. Mike [Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States); Ngwa, Wilfred, E-mail: wngwa@lroc.harvard.edu [Department of Physics and Applied Physics, University of Massachusetts, Lowell, Massachusetts (United States); Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital and Harvard Medical School, Boston, Massachusetts (United States)

    2015-02-01

    Purpose: Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A new strategy proposed for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in situ release after implantation. This in silico study investigated the intratumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials: An experimentally determined intratumoral diffusion coefficient (D) for 10-nm nanoparticles was used to estimate D for other sizes by using the Stokes-Einstein equation. GNP concentration profiles, obtained using D, were then used to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel, using dose painting-by-numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation was carried out as a function of GNP size for the clinically applicable low-dose-rate brachytherapy sources iodine-125 (I-125), palladium-103 (Pd-103), and cesium-131 (Cs-131). Results: Results showed that dose enhancement to tumor voxels and subvolumes during brachytherapy can be customized by varying the size of GNP released or eluted from the GBS. For example, using a concentration of 7 mg/g GNP, significant DEF (>20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNP sizes of 2, 5, 10, 20, 30, and 50 nm and for 80 nm when treating with I-125. Conclusions: Analyses showed that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. These findings provide a useful reference for further work toward development of potential new brachytherapy application

  11. Fast and Cost-Effective Biochemical Spectrophotometric Analysis of Solution of Insect “Blood” and Body Surface Elution

    OpenAIRE

    Aleksandra Łoś; Aneta Strachecka

    2018-01-01

    Using insect hemolymph (“blood”) and insect body surface elutions, researchers can perform rapid and cheap biochemical analyses to determine the insect’s immunology status. The authors of this publication describe a detailed methodology for a quick marking of the concentration of total proteins and evaluation of the proteolytic system activity (acid, neutral, and alkaline proteases and protease inhibitors), as well as a methodology for quick “liver” tests in insects: alanine aminotransferase ...

  12. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon; Seo, Tae-Seok; Yuk, Soon Hong; Kim, Young-Hwa; Cho, Yong-Mee

    2005-01-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean±standard deviation, 46.88±23.75) than in the CS (73.75±14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63±2.05) than in CS (3.49±2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  13. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, Seoul (Korea); Seo, Tae-Seok [Gachon Medical School, Department of Radiology, Gil Medical Center, Inchon (Korea); Yuk, Soon Hong [Hannam University, Department of Polymer Science and Engineering, College of Engineering, Daejeon (Korea); Kim, Young-Hwa [Soonchunhyang University Chonan Hospital, Department of Radiology, Chonan (Korea); Cho, Yong-Mee [University of Ulsan College of Medicine, Department of Pathology, Asan Medical Center, Seoul (Korea)

    2005-06-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean{+-}standard deviation, 46.88{+-}23.75) than in the CS (73.75{+-}14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63{+-}2.05) than in CS (3.49{+-}2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  14. Long-Term Follow-up of the PADI Trial : Percutaneous Transluminal Angioplasty Versus Drug-Eluting Stents for Infrapopliteal Lesions in Critical Limb Ischemia

    NARCIS (Netherlands)

    Spreen, Marlon I; Martens, Jasper M; Knippenberg, Bob; van Dijk, Lukas C; De Vries, Jean-Paul P. M.; Vos, Jan Albert; de Borst, Gert Jan; Vonken, Evert-Jan P A; Bijlstra, Okker D; Wever, Jan J; Statius van Eps, Randolph G; Mali, Willem P Th M; van Overhagen, Hendrik

    2017-01-01

    BACKGROUND: Clinical outcomes reported after treatment of infrapopliteal lesions with drug-eluting stents (DESs) have been more favorable compared with percutaneous transluminal angioplasty with a bailout bare metal stent (PTA-BMS) through midterm follow-up in patients with critical limb ischemia.

  15. A randomized comparison of novel bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with acute coronary syndromes: The CENTURY II high risk ACS substudy

    International Nuclear Information System (INIS)

    Jiménez, Victor A.; Iñiguez, Andrés; Baz, José A.; Valdés, Mariano; Ortiz, Alberto; Vuilliomenet, André; Mainar, Vicente; Dudek, Dariusz; Banai, Shmuel; Tüller, David; Bonnet, Jean-Louis; De Miguel, Antonio; Bastos, Guillermo; Wijns, William; Saito, Shigeru

    2016-01-01

    Background: To investigate clinical outcomes of percutaneous coronary intervention using a sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES) compared with a permanent polymer everolimus-eluting stent, Xience (PP-EES) in patients with high risk (ST-segment elevation and non-ST-segment elevation myocardial infarction) acute coronary syndromes (ACS) enrolled in the CENTURY II trial. Methods: CENTURY II is a prospective, multicenter, randomized, single blind, controlled trial comparing BP-SES and PP-EES, with primary endpoint of target lesion failure (TLF) at 9 month post-stent implantation. Out of 1123 patients enrolled in CENTURY II trial, 264 high risk ACS patients were included in this subgroup analysis, and the clinical outcomes including target lesion failure (TLF), target vessel failure (TVF), cardiac death, myocardial infarction, and stent thrombosis were evaluated at 24 months. Results: The baseline clinical, angiographic and procedural characteristics were similar between two groups. At 24 months, TLF occurred in 6.3% of patients receiving a BP-SES and 6.5% of patients receiving a PP-EES (P = 0.95); TVF was 6.3% in patients receiving a BP-SES and 9.4% in patients receiving a PP-EES (P = 0.36). There were no significant differences in cardiac death, myocardial infarction and stent thrombosis rate. Conclusions: BP-SES achieved similar safety and efficacy outcomes as PP-EES in this ACS subgroup of CENTURY II study, at 24-month follow-up. This finding is hypothesis-generating and needs to be confirmed in larger trials with longer follow-up. - Highlights: • This study reported the 24-month clinical outcomes of new-generation BP-SES compared with PP-EES in ACS subgroup from CENTURY II study. • This is a pre-specified subgroup analysis of a large randomized, prospective, multicenter clinical trial. • The BP-SES showed good and comparable clinical performance as PP-EES at 24 months. • This substudy has a relatively small sample size and

  16. A randomized comparison of novel bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with acute coronary syndromes: The CENTURY II high risk ACS substudy

    Energy Technology Data Exchange (ETDEWEB)

    Jiménez, Victor A., E-mail: victor.alfonso.jimenez.diaz@sergas.es [Interventional Cardiology Unit, Cardiology Department, Hospital Alvaro Cunqueiro, University Hospital of Vigo, Vigo (Spain); Iñiguez, Andrés; Baz, José A. [Interventional Cardiology Unit, Cardiology Department, Hospital Alvaro Cunqueiro, University Hospital of Vigo, Vigo (Spain); Valdés, Mariano [Hospital Universitario V. Arrixaca, Murcia (Spain); Ortiz, Alberto [Interventional Cardiology Unit, Cardiology Department, Hospital Alvaro Cunqueiro, University Hospital of Vigo, Vigo (Spain); Vuilliomenet, André [Kantonsspital Aarau, Aarau (Switzerland); Mainar, Vicente [Department of Cardiology, University General Hospital of Alicante, Alicante (Spain); Dudek, Dariusz [Department of Interventional Cardiology, Jagiellonian University Medical College, Krakow (Poland); Banai, Shmuel [Tel Aviv Sourasky Medical Centre, Tel Aviv (Israel); Tüller, David [Department of Cardiology, Stadtspital Triemli, Zürich (Switzerland); Bonnet, Jean-Louis [Department of Cardiology, Hospital La Timone, Marseille (France); De Miguel, Antonio; Bastos, Guillermo [Interventional Cardiology Unit, Cardiology Department, Hospital Alvaro Cunqueiro, University Hospital of Vigo, Vigo (Spain); Wijns, William [Cardiovascular Center Aalst, OLV Hospital, Aalst (Belgium); Saito, Shigeru [Department of Cardiology and Catheterization Laboratory, Shonan Kamakura General Hospital, Kamakura (Japan)

    2016-09-15

    Background: To investigate clinical outcomes of percutaneous coronary intervention using a sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES) compared with a permanent polymer everolimus-eluting stent, Xience (PP-EES) in patients with high risk (ST-segment elevation and non-ST-segment elevation myocardial infarction) acute coronary syndromes (ACS) enrolled in the CENTURY II trial. Methods: CENTURY II is a prospective, multicenter, randomized, single blind, controlled trial comparing BP-SES and PP-EES, with primary endpoint of target lesion failure (TLF) at 9 month post-stent implantation. Out of 1123 patients enrolled in CENTURY II trial, 264 high risk ACS patients were included in this subgroup analysis, and the clinical outcomes including target lesion failure (TLF), target vessel failure (TVF), cardiac death, myocardial infarction, and stent thrombosis were evaluated at 24 months. Results: The baseline clinical, angiographic and procedural characteristics were similar between two groups. At 24 months, TLF occurred in 6.3% of patients receiving a BP-SES and 6.5% of patients receiving a PP-EES (P = 0.95); TVF was 6.3% in patients receiving a BP-SES and 9.4% in patients receiving a PP-EES (P = 0.36). There were no significant differences in cardiac death, myocardial infarction and stent thrombosis rate. Conclusions: BP-SES achieved similar safety and efficacy outcomes as PP-EES in this ACS subgroup of CENTURY II study, at 24-month follow-up. This finding is hypothesis-generating and needs to be confirmed in larger trials with longer follow-up. - Highlights: • This study reported the 24-month clinical outcomes of new-generation BP-SES compared with PP-EES in ACS subgroup from CENTURY II study. • This is a pre-specified subgroup analysis of a large randomized, prospective, multicenter clinical trial. • The BP-SES showed good and comparable clinical performance as PP-EES at 24 months. • This substudy has a relatively small sample size and

  17. Determination of zearalenone content in cereals and feedstuffs by immunoaffinity column coupled with liquid chromatography.

    Science.gov (United States)

    Fazekas, B; Tar, A

    2001-01-01

    The zearalenone content of maize, wheat, barley, swine feed, and poultry feed samples was determined by immunoaffinity column cleanup followed by liquid chromatography (IAC-LC). Samples were extracted in methanol-water (8 + 2, v/v) solution. The filtered extract was diluted with distilled water and applied to immunoaffinity columns. Zearalenone was eluted with methanol, dried by evaporation, and dissolved in acetonitrile-water (3 + 7, v/v). Zearalenone was separated by isocratic elution of acetonitrile-water (50 + 50, v/v) on reversed-phase C18 column. The quantitative analysis was performed by fluorescence detector and confirmation was based on the UV spectrum obtained by a diode array detector. The mean recovery rate of zearalenone was 82-97% (RSD, 1.4-4.1%) on the original (single-use) immunoaffinity columns. The limit of detection of zearalenone by fluorescence was 10 ng/g at a signal-to-noise ratio of 10:1 and 30 ng/g by spectral confirmation in UV. A good correlation was found (R2 = 0.89) between the results obtained by IAC-LC and by the official AOAC-LC method. The specificity of the method was increased by using fluorescence detection in parallel with UV detection. This method was applicable to the determination of zearalenone content in cereals and other kinds of feedstuffs. Reusability of immunoaffinity columns was examined by washing with water after sample elution and allowing columns to stand for 24 h at room temperature. The zearalenone recovery rate of the regenerated columns varied between 79 and 95% (RSD, 3.2-6.3%). Columns can be regenerated at least 3 times without altering their performance and without affecting the results of repeated determinations.

  18. Chemoembolization (TACE) of Unresectable Intrahepatic Cholangiocarcinoma with Slow-Release Doxorubicin-Eluting Beads: Preliminary Results

    International Nuclear Information System (INIS)

    Aliberti, Camillo; Benea, Giorgio; Tilli, Massimo; Fiorentini, Giammaria

    2008-01-01

    The purpose of this study was to evaluate the safety and efficacy of TACE with microspheres preloaded with doxorubicin in unresectable intrahepatic cholangiocarcinoma (UCH). Twenty patients with UCH were observed; 9 refused, preferring other palliative care or chemotherapy, and 11 agreed to be treated with one or more cycles of DC beads loaded with doxorubicin (100-150 mg) in a TACE procedure between February 2006 and September 2007. A total of 29 individual TACE procedures were performed. Follow-up imaging was performed on all patients before, immediately after, and 4 weeks after each TACE procedure to evaluate the response and need for further treatment. Each patient received i.v hydration, antibiotics, and medications against nausea and pain before TACE. Survival rate was calculated using Kaplan-Meier survival curve. A response rate of 100% followed RECIST criteria was observed. Eight of eleven patients are alive, with a median survival of 13 months. TACE was well tolerated by all patients. One patient developed hepatic abscess requiring antibiotic therapy. No evidence of marrow toxicity has been reported. Only one of nine patients treated with chemotherapy or palliative care is alive (with a median survival of 7 months in this group of patients). In conclusion, we suggest that doxorubicin-eluting beads TACE is a feasible and effective treatment in patients with UCH. Survival seems to be clearly prolonged in the treated group with respect to the palliative group. We consider that doxorubicin-eluting beads TACE of 100-150 mg may be an appropriate palliative therapy for these patients. Further studies are warranted to confirm these interesting preliminary data.

  19. Chromatographic determination of Fe chelated by ethylenediamine-N-(o-hydroxyphenylacetic)-N'-(p-hydroxyphenylacetic) acid in commercial EDDHA/Fe3+ fertilizers.

    Science.gov (United States)

    García-Marco, Sonia; Torreblanca, Ana; Lucena, Juan J

    2006-02-22

    EDDHA/Fe3+ chelates are the most common fertilizers used to solve Fe chlorosis in established crops. Commercial products contain two regioisomers, ethylenediamine-N,N'-bis(o-hydroxyphenylacetic) acid (o,o-EDDHA)/Fe3+ and ethylenediamine-N-(o-hydroxyphenylacetic)-N'-(p-hydroxyphenylacetic) acid (o,p-EDDHA)/Fe3+. Although several chromatographic methods exist for the determination of Fe3+ chelated by the o,o-EDDHA isomer, no method has been described for the quantification of Fe3+ chelated by o,p-EDDHA. In this work, factors that affect the behavior of o,p-EDDHA/Fe3+ in ion pair chromatography are reviewed: pH, ion pair reagent, and organic modifier. The best chromatographic performance was obtained with an aqueous mobile phase at pH 6.0 containing 35% acetonitrile and 5 mM tetrabutylammonium hydroxide under isocratic elution conditions. This method was applied to the quantification of commercial samples.

  20. [Study on the analytical methods of catechins in tea and green tea polyphenol samples by high performance liquid chromatography].

    Science.gov (United States)

    Dai, J; Wang, H X; Chen, S W; Tang, J

    2001-09-01

    Hypersil BDS C18 and Zorbax SB C18, suitable to separate simultaneously seven kinds of catechins and caffeine, were screened out from seven brands of reversed-phase columns. Mobile phase was a solution of methanol-water-acetic acid (or trifluoro acetic acid). Seven kinds of catechins in tea samples from six places in China and three green tea polyphenol(GTP) samples from different producers were separated and determined in 30 min by isocratic and gradient elutions. The effects of mobile phase components and temperature of column on retention parameters of catechins and caffeine are reviewed. Chromatographic conditions and pretreatment methods of samples were optimized. Gallocatechin gallate(GCG) and (-)-catechin gallate(CG) were identified by electrospray ionization mass spectrometry(ESI-MS) and prepared by high performance liquid chromatography for quantitative analysis. The other catechins, (-)-epigallocatechin (EGC), (+)-catechin (D-C), (-)-epicatechin(EC), (-)-epigallocatechin gallate(EGCG), (-)-epicatechin gallate(ECG) were identified with standards.

  1. Serial assessment by optical coherence tomography of early and late vascular responses after implantation of an absorbable-coating Sirolimus-Eluting stent (from the first-in-human DESSOLVE I trial).

    Science.gov (United States)

    Attizzani, Guilherme F; Bezerra, Hiram G; Ormiston, John; Wang, Wei; Donohoe, Dennis; Wijns, William; Costa, Marco A

    2013-11-15

    The initial enthusiasm caused by the potent antirestenotic effect of early generation drug-eluting stents was recently plagued by concerns regarding their safety profile. Investigators worldwide were stimulated, therefore, to seek for improvement in drug-eluting stent technology, such as eliminating their permanent polymer blamed for vascular inflammation and delayed healing. Optical coherence tomography (OCT) assessments of stent-vessel interactions are used as a surrogate for vessel healing after DES implantation. Herewith, we report serial OCT assessments of vascular reactions to the implantation of a novel absorbable polymer sirolimus-eluting stent (MiStent). In total, 30 patients were included. At 4-, 6-, and 8-month follow-up, different groups of 10 patients underwent OCT imaging, whereas all the patients had OCT assessments scheduled at 18-month follow-up. A total of 13,569 stent struts were analyzed. Low rates of uncovered (14.34 ± 15.35%, 6.62 ± 10.93%, 3.51 ± 2.87%, and 0.84 ± 1.15%, respectively, p stent struts coupled with thin and increasingly homogenous neointimal proliferation were demonstrated. Neointimal area increased from 4- to 8-month follow-up (0.46 ± 0.29 and 1.12 ± 0.73 mm(2), respectively, p stent struts (8.8%, 3.1%, 0.3%, and 0%, respectively, p absorbable polymer sirolimus-eluting stent-vessel interactions up to 18-month follow-up. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Comparison between the STENTYS self-apposing bare metal and paclitaxel-eluting coronary stents for the treatment of saphenous vein grafts (ADEPT trial)

    NARCIS (Netherlands)

    A.J.J. IJsselmuiden (Alexander); C. Simsek (Cihan); Van Driel, A.G. (A. G.); Bouchez, D. (D.); G. Amoroso (Giovanni); P. Vermeersch (Paul); Karjalainen, P.P. (P. P.)

    2018-01-01

    textabstractAims To describe the safety and performance of STENTYS self-expandable bare metal stents (BMS) versus paclitaxel-eluting stents (PES) in saphenous vein grafts (SVGs). Methods and Results A randomised controlled trial was performed in four hospitals in three European countries between

  3. A randomized study to compare bioactive titanium stents and everolimus-eluting stents in diabetic patients (TITANIC XV): 1-year results.

    Science.gov (United States)

    López-Mínguez, José R; Nogales-Asensio, Juan M; Doncel-Vecino, Luis J; Merchán-Herrera, Antonio; Pomar-Domingo, Francisco; Martínez-Romero, Pedro; Fernández-Díaz, José A; Valdesuso-Aguilar, Raúl; Moreu-Burgos, José; Díaz-Fernández, José

    2014-07-01

    Up to 25% of patients who undergo a percutaneous coronary intervention show some limitation in the use of drug-eluting stents. The aim of this study was to evaluate if titanium-nitride-oxide-coated stents could be a good alternative to everolimus-eluting stents in diabetic patients. A total of 173 diabetic patients with lesions at moderate risk of restenosis (exclusion criteria: diameter 28 mm in vessels < 3mm, chronic occlusion) were randomized to a titanium group (83 patients) or an everolimus group (90 patients). Baseline characteristics were well balanced; 28.3% of patients were insulin dependent. At 1 year, the incidence of major adverse cardiac events (death, nonfatal myocardial infarction, stroke, or repeat target vessel revascularization) was significantly higher in the titanium group than in the everolimus group (total, 14.5% vs 4.4%; P = .02; noninsulin-dependent subgroup, 9.7% vs 3.2%; P = .14; insulin-dependent subgroup, 28.6% vs 7.1%; P = .04). The incidence of death, nonfatal myocardial infarction, stroke, or any revascularization was 16.9% in the titanium group and 7.8% in the everolimus group (P = .06). Target lesion and vessel revascularizations occurred in 8.4% compared with 3.3% (P = .15) and in 13.3% compared with 3.3% (P = .01) in the titanium and everolimus groups, respectively. Angiographic follow-up at 9 months showed significantly less late lumen loss in the everolimus group (in-segment, 0.52 [standard deviation, 0.58) mm vs -0.05 [0.32] mm; in-stent, 0.76 [0.54] mm vs 0.13 [0.31] mm; P < .0001). The everolimus-eluting stent is superior to the titanium stent for clinical and angiographic end points in diabetic patients with lesions at moderate risk of restenosis. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  4. Impedance Changes and Fibrous Tissue Growth after Cochlear Implantation Are Correlated and Can Be Reduced Using a Dexamethasone Eluting Electrode.

    Directory of Open Access Journals (Sweden)

    Maciej Wilk

    Full Text Available The efficiency of cochlear implants (CIs is affected by postoperative connective tissue growth around the electrode array. This tissue formation is thought to be the cause behind post-operative increases in impedance. Dexamethasone (DEX eluting CIs may reduce fibrous tissue growth around the electrode array subsequently moderating elevations in impedance of the electrode contacts.For this study, DEX was incorporated into the silicone of the CI electrode arrays at 1% and 10% (w/w concentration. Electrodes prepared by the same process but without dexamethasone served as controls. All electrodes were implanted into guinea pig cochleae though the round window membrane approach. Potential additive or synergistic effects of electrical stimulation (60 minutes were investigated by measuring impedances before and after stimulation (days 0, 7, 28, 56 and 91. Acoustically evoked auditory brainstem responses were recorded before and after CI insertion as well as on experimental days 7, 28, 56, and 91. Additionally, histology performed on epoxy embedded samples enabled measurement of the area of scala tympani occupied with fibrous tissue.In all experimental groups, the highest levels of fibrous tissue were detected in the basal region of the cochlea in vicinity to the round window niche. Both DEX concentrations, 10% and 1% (w/w, significantly reduced fibrosis around the electrode array of the CI. Following 3 months of implantation impedance levels in both DEX-eluting groups were significantly lower compared to the control group, the 10% group producing a greater effect. The same effects were observed before and after electrical stimulation.To our knowledge, this is the first study to demonstrate a correlation between the extent of new tissue growth around the electrode and impedance changes after cochlear implantation. We conclude that DEX-eluting CIs are a means to reduce this tissue reaction and improve the functional benefits of the implant by attenuating

  5. Overtime evaluation of the vascular HEALing process after everolimus-eluting stent implantation by optical coherence tomography. The HEAL-EES study

    Energy Technology Data Exchange (ETDEWEB)

    Otsuki, Shuji; Brugaletta, Salvatore, E-mail: sabrugal@clinic.ub.es; Sabaté, Manel; Shiratori, Yoshitaka; Gomez-Monterrosas, Omar; Scalone, Giancarla; Romero-Villafañe, Sebastian; Hernández-Enríquez, Marco; Freixa, Xavier; Martín-Yuste, Victoria; Masotti, Mónica

    2016-06-15

    Purpose: Second-generation drug-eluting stent (DES) have shown a better safety and efficacy as compared to first generation DES due to an improved vascular healing process. This process has not been so far evaluated in vivo in an overtime fashion by optical coherent tomography (OCT). We sought to evaluate the vascular healing process after everolimus-eluting stent (EES) implantation at 6, 9 and 12 months, by OCT. Methods: Consecutive 36 patients undergoing percutaneous coronary intervention with EES were randomized 1:1:1 to receive OCT imaging at 6 (group A), 9 (group B) or 12-month follow-up (group C). One patient from group C was excluded because of target lesion revascularization at 1-month, whereas 5 patients withdraw the informed consent. Finally, 30 patients were analyzed. Results: Neointimal thickness was not different between 3 groups (group A: 99.50 [94.06–127.79] μm, group B: 107.26 [83.48–133.59] μm, group C: 127.67 [102.51–138.49] μm; p = 0.736). Although the percentage of “uncovered struts” was significantly higher in group A as compared to the other groups (8.0% vs. 4.4% vs. 2.9%, respectively; p = 0.180), the ratio of uncovered to total struts per section < 30% was similar between 3 groups (0.3% vs. 0.3% vs. 0%, respectively; p = 1.000). Conclusion: Healing process following EES implantation seems almost completed at 6-month follow-up. These data, which need to be confirmed in a larger study, may support the decision to shorten dual antiplatelet therapy. - Highlights: • Healing process following everolimus-eluting stent implantation is complete at 6-month • There are no difference in RUTTS > 30% between 6, 9 and 12 months analyses. • This finding may support to shorten dual antiplatelet therapy in this context.

  6. Development and validation of a novel LC non-derivatization method for the determination of amikacin in pharmaceuticals based on evaporative light scattering detection.

    Science.gov (United States)

    Galanakis, Evagelia G; Megoulas, Nikolaos C; Solich, Petr; Koupparis, Michael A

    2006-03-18

    A novel method for the direct determination of the aminoglycoside antibiotic amikacin and its precursor component kanamycin was developed and validated, based on reversed phase LC with evaporative light scattering detector (ELSD). ELSD response to amikacin was found to be enhanced by: (a) use of ion-pairing acidic reagents of increased molecular mass, (b) increase of mobile phase volatility and (c) decrease of peak width and asymmetry (obtained by controlling the mobile phase acidity and/or ratio of organic solvent to water). Utilizing a Thermo Hypersil BetaBasic C(18) column, the selected optimized mobile phase was water-methanol (60:40, v/v), containing 3.0 mll(-1) nonafluoropentanoic acid (18.2mM) (isocratic elution with flow rate of 1.0 mlmin(-1)). ELSD experimental parameters were: nitrogen pressure 3.5 bar, evaporation temperature 50 degrees C, and gain 11. Amikacin was eluted at 8.6 min and kanamycin at 10.4 min with a resolution of 1.5. Logarithmic calibration curves were obtained from 7 to 77 microgml(-1) (r>0.9995) for amikacin and 8 to 105 microgml(-1) (r>0.998) for kanamycin, with a LOD equal to 2.2 and 2.5 microgml(-1), respectively. In amikacin sulfate pharmaceutical raw materials, the simultaneous determination of sulfate (t(R)=2.3 min, LOD=1.8 microgml(-1), range 5-40 microgml(-1), %R.S.D.=1.1, r>0.9997), kanamycin and amikacin was feasible. No significant difference was found between the results of the developed LC-ELSD method and those of reference methods, while the mean recovery of kanamycin from spiked samples (0.5%, w/w) was 97.3% (%R.S.D.

  7. Highly crosslinked polymeric monoliths for reversed-phase capillary liquid chromatography of small molecules.

    Science.gov (United States)

    Liu, Kun; Tolley, H Dennis; Lee, Milton L

    2012-03-02

    Seven crosslinking monomers, i.e., 1,3-butanediol dimethacrylate (1,3-BDDMA), 1,4-butanediol dimethacrylate (1,4-BDDMA), neopentyl glycol dimethacrylate (NPGDMA), 1,5-pentanediol dimethacrylate (1,5-PDDMA), 1,6-hexanediol dimethacrylate (1,6-HDDMA), 1,10-decanediol dimethacrylate (1,10-DDDMA), and 1,12-dodecanediol dimethacrylate (1,12-DoDDMA), were used to synthesize highly cross-linked monolithic capillary columns for reversed-phase liquid chromatography (RPLC) of small molecules. Dodecanol and methanol were chosen as "good" and "poor" porogenic solvents, respectively, for these monoliths, and were investigated in detail to provide insight into the selection of porogen concentration using 1,12-DoDDMA. Isocratic elution of alkylbenzenes at a flow rate of 300 nL/min was conducted for all of the monoliths. Gradient elution of alkylbenzenes and alkylparabens provided high resolution separations. Optimized monoliths synthesized from all seven crosslinking monomers showed high permeability. Several of the monoliths demonstrated column efficiencies in excess of 50,000 plates/m. Monoliths with longer alkyl-bridging chains showed very little shrinking or swelling in solvents of different polarities. Column preparation was highly reproducible; the relative standard deviation (RSD) values (n=3) for run-to-run and column-to-column were less than 0.25% and 1.20%, respectively, based on retention times of alkylbenzenes. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Clinical outcomes in low risk coronary artery disease patients treated with different limus-based drug-eluting stents--a nationwide retrospective cohort study using insurance claims database.

    Directory of Open Access Journals (Sweden)

    Chao-Lun Lai

    Full Text Available The clinical outcomes of different limus-based drug-eluting stents (DES in a real-world setting have not been well defined. The aim of this study was to investigate the clinical outcomes of three different limus-based DES, namely sirolimus-eluting stent (SES, Endeavor zotarolimus-eluting stent (E-ZES and everolimus-eluting stent (EES, using a national insurance claims database. We identified all patients who received implantation of single SES, E-ZES or EES between January 1, 2007 and December 31, 2009 from the National Health Insurance claims database, Taiwan. Follow-up was through December 31, 2011 for all selected clinical outcomes. The primary end-point was all-cause mortality. Secondary end-points included acute coronary events, heart failure needing hospitalization, and cerebrovascular disease. Cox regression model adjusting for baseline characteristics was used to compare the relative risks of different outcomes among the three different limus-based DES. Totally, 6584 patients were evaluated (n=2142 for SES, n=3445 for E-ZES, and n=997 for EES. After adjusting for baseline characteristics, we found no statistically significant difference in the risk of all-cause mortality in three DES groups (adjusted hazard ratio [HR]: 1.14, 95% confidence interval [CI]: 0.94-1.38, p=0.20 in E-ZES group compared with SES group; adjusted HR: 0.77, 95% CI: 0.54-1.10, p=0.15 in EES group compared with SES group. Similarly, we found no difference in the three stent groups in risks of acute coronary events, heart failure needing hospitalization, and cerebrovascular disease. In conclusion, we observed no difference in all-cause mortality, acute coronary events, heart failure needing hospitalization, and cerebrovascular disease in patients treated with SES, E-ZES, and EES in a real-world population-based setting in Taiwan.

  9. Risk factors for impaired health status differ in women and men treated with percutaneous coronary intervention in the drug-eluting stent era

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Ong, Andrew T L; Lemos, Pedro A

    2006-01-01

    In patients treated with percutaneous coronary intervention (PCI) in the drug-eluting stent era, we compared women's and men's health status 6 and 12 months post-PCI and investigated whether predictors of poor health status at 12 months are similar for women and men....

  10. Bradycardia Associated With Drug-Eluting Beads Loaded With Irinotecan (DEBIRI) Infusion for Colorectal Liver Metastases

    International Nuclear Information System (INIS)

    Pua, Uei

    2013-01-01

    Intra-arterial injection of drug-eluting beads loaded with irinotecan (DEBIRI) is a new treatment option being investigated, with encouraging results, for unresectable colorectal liver metastases that are refractory to systemic chemotherapy (Martin et al., Ann Surg Oncol 18:192–198, 2011). Toxicity related to DEBIRI has also been described (Martin et al., Cardiovasc Intervent Radiol 33:960–966, 2010). Nevertheless, experience and literature related to DEBIRI remain limited, and experience with this treatment is expected to increase. The purpose of this article is to describe bradycardia occurring during DEBIRI administration, which has not been reported thus far.

  11. Bradycardia Associated With Drug-Eluting Beads Loaded With Irinotecan (DEBIRI) Infusion for Colorectal Liver Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2013-06-15

    Intra-arterial injection of drug-eluting beads loaded with irinotecan (DEBIRI) is a new treatment option being investigated, with encouraging results, for unresectable colorectal liver metastases that are refractory to systemic chemotherapy (Martin et al., Ann Surg Oncol 18:192-198, 2011). Toxicity related to DEBIRI has also been described (Martin et al., Cardiovasc Intervent Radiol 33:960-966, 2010). Nevertheless, experience and literature related to DEBIRI remain limited, and experience with this treatment is expected to increase. The purpose of this article is to describe bradycardia occurring during DEBIRI administration, which has not been reported thus far.

  12. First-in-man study of simvastatin-eluting stent in de novo coronary lesions: the SIMVASTENT study.

    Science.gov (United States)

    Zago, Alexandre C; Matte, Bruno S; Reginato, Luciana; Iturry-Yamamoto, Germán; Krepsky, Ana; Bergoli, Luiz Carlos C; Balvedi, Julise; Raudales, José C; Saadi, Eduardo K; Zago, Alcides J

    2012-01-01

    Statins have anti-inflammatory and antiproliferative properties irrespective of their cholesterol-lowering effects. The aim of the present study was to evaluate a simvastatin-eluting stent (SimvES) in the treatment of de novo coronary lesions. Forty-two patients with de novo coronary artery lesions were assigned to SimvES, bare-metal stent (BMS) or everolimus-eluting stent (EES) implantation followed by intravascular ultrasound (IVUS) for neointimal quantitative analysis. Six months later, quantitative coronary angiography (QCA) and IVUS were repeated. QCA showed no binary restenosis, a mean in-stent late loss of 1.05 ± 0.25 mm (BMS, 1.12 ± 0.48 mm; EES, 0.20 ± 0.16 mm) and a diameter stenosis of 33.5 ± 7.1% (BMS, 35.5 ± 15.30%; EES, 7.2 ± 3.12%). Control IVUS showed a mean in-stent obstruction of 18.3 ± 9.4% (BMS, 32.8 ± 19.1%; EES, 9.8 ± 2.4%) and a neointimal volume index of 1.58 ± 0.75 mm(3)/mm (BMS, 2.93 ± 1.76 mm(3)/mm; EES, 0.80 ± 0.16 mm(3)/mm). Thrombus, late incomplete apposition and major adverse cardiac events were not observed. In this sample of patients with de novo coronary lesions, the use of a SimvES was not related to major adverse cardiac events, but it was associated with a higher level of neointimal proliferation than expected.

  13. Prediction of the retention of s-triazines in reversed-phase high-performance liquid chromatography under linear gradient-elution conditions.

    Science.gov (United States)

    D'Archivio, Angelo Antonio; Maggi, Maria Anna; Ruggieri, Fabrizio

    2014-08-01

    In this paper, a multilayer artificial neural network is used to model simultaneously the effect of solute structure and eluent concentration profile on the retention of s-triazines in reversed-phase high-performance liquid chromatography under linear gradient elution. The retention data of 24 triazines, including common herbicides and their metabolites, are collected under 13 different elution modes, covering the following experimental domain: starting acetonitrile volume fraction ranging between 40 and 60% and gradient slope ranging between 0 and 1% acetonitrile/min. The gradient parameters together with five selected molecular descriptors, identified by quantitative structure-retention relationship modelling applied to individual separation conditions, are the network inputs. Predictive performance of this model is evaluated on six external triazines and four unseen separation conditions. For comparison, retention of triazines is modelled by both quantitative structure-retention relationships and response surface methodology, which describe separately the effect of molecular structure and gradient parameters on the retention. Although applied to a wider variable domain, the network provides a performance comparable to that of the above "local" models and retention times of triazines are modelled with accuracy generally better than 7%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Development and Validation of a Rapid RP-HPLC Method for the Determination of Venlafaxine Hydrochloride in Pharmaceutical Dosage forms using Experimental Design

    Directory of Open Access Journals (Sweden)

    Vanita Somasekhar

    2009-01-01

    Full Text Available The objective of the current study was to develop a simple, accurate, precise and rapid reversed-phase HPLC method and subsequent validation as per ICH guidelines for the determination of venlafaxine hydrochloride in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a 5 μm Varian® Microsorb-MV 100 C18 column (250 mmx4.6 mm at ambient temperature. A 23 factorial design consisting of 3 factors at 2 levels was set up to standardize the chromatographic conditions. A numerical optimization technique employing the desirability approach was used to locate the optimum chromatographic conditions. The optimum mobile phase consisted of acetonitrile, 0.04 M potassium dihydrogen phosphate buffer and methanol (45:25:30, v/v, with pH adjusted to 5.5 using 10% phosphoric acid solution. The mobile phase was delivered isocratically at a flow rate of 1 mL/min with UV detection at 224 nm. The calibration plots constructed using the optimized chromatographic conditions displayed good linear relationship in the concentration range of 1-50 μg/mL with r=0.9992. The method was validated for precision, accuracy, robustness and recovery. The minimum detectable and minimum quantifiable amounts were found to be 0.568 and 1.72 μg/mL, respectively and the method was found to be reproducible from the statistical data generated. Venlafaxine hydrochloride was eluted at 3.43 min

  15. Comprehensive analysis of pharmaceutical products using simultaneous mixed-mode (ion-exchange/reversed-phase) and hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Kazarian, Artaches A; Nesterenko, Pavel N; Soisungnoen, Phimpha; Burakham, Rodjana; Srijaranai, Supalax; Paull, Brett

    2014-08-01

    Liquid chromatographic assays were developed using a mixed-mode column coupled in sequence with a hydrophilic interaction liquid chromatography column to allow the simultaneous comprehensive analysis of inorganic/organic anions and cations, active pharmaceutical ingredients, and excipients (carbohydrates). The approach utilized dual sample injection and valve-mediated column switching and was based upon a single high-performance liquid chromatography gradient pump. The separation consisted of three distinct sequential separation mechanisms, namely, (i) ion-exchange, (ii) mixed-mode interactions under an applied dual gradient (reversed-phase/ion-exchange), and (iii) hydrophilic interaction chromatography. Upon first injection, the Scherzo SS C18 column (Imtakt) provided resolution of inorganic anions and cations under isocratic conditions, followed by a dual organic/salt gradient to elute active pharmaceutical ingredients and their respective organic counterions and potential degradants. At the top of the mixed-mode gradient (high acetonitrile content), the mobile phase flow was switched to a preconditioned hydrophilic interaction liquid chromatography column, and the standard/sample was reinjected for the separation of hydrophilic carbohydrates, some of which are commonly known excipients in drug formulations. The approach afforded reproducible separation and resolution of up to 23 chemically diverse solutes in a single run. The method was applied to investigate the composition of commercial cough syrups (Robitussin®), allowing resolution and determination of inorganic ions, active pharmaceutical ingredients, excipients, and numerous well-resolved unknown peaks. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Antirestenotic Effects of a Novel Polymer-Coated D-24851 Eluting Stent. Experimental Data in a Rabbit Iliac Artery Model

    International Nuclear Information System (INIS)

    Lysitsas, Dimitrios N.; Katsouras, Christos S.; Papakostas, John C.; Toumpoulis, Ioannis K.; Angelidis, Charalampos; Bozidis, Petros; Thomas, Christopher G.; Seferiadis, Konstantin; Psychoyios, Nikolaos; Frillingos, Stathis; Pavlidis, Nikolaos; Marinos, Euaggelos; Khaldi, Lubna; Sideris, Dimitris A.; Michalis, Lampros K.

    2007-01-01

    Experimental and clinical data suggest that stents eluting antiproliferative agents can be used for the prevention of in-stent restenosis. Here we investigate in vitro the antiproliferative and apoptotic effect of D-24851 and evaluate the safety and efficacy of D-24851-eluting polymer-coated stents in a rabbit restenosis model (n = 53). Uncoated stents (n = 6), poly (dl-lactide-co-glycolide) (PLGA)-coated stents (n = 7), and PLGA-coated stents loaded with 0.08 ± 0.0025 μM (31 ± 1 μg; low dose; n = 7), 0.55 ± 0.02 μM (216 ± 8 μg; high dose; n = 6), and 4.55 ± 0.1 μM (1774 ± 39 μg; extreme dose; n = 5) of D-24851 were randomly implanted in New Zealand rabbit right iliac arteries and the animals were sacrificed after 28 days for histomorphometric analysis. For the assessment of endothelial regrowth in 90 days, 12 rabbits were subjected to PLGA-coated (n = 3), low-dose (n = 3), high-dose (n = 3), and extreme-dose (n = 3) stent implantation. In vitro studies revealed that D-24851 exerts its growth inhibitory effects via inhibition of proliferation and induction of apoptosis without increasing the expression of heat shock protein-70, a cytoprotective and antiapoptotic protein. Treatment with low-dose D-24851 stents was associated with a significant reduction in neointimal area and percentage stenosis only compared with bare metal stents (38% [P = 0.029] and 35% [P = 0.003] reduction, respectively). Suboptimal healing, however, was observed in all groups of D-24851-loaded stents in 90 days in comparison with PLGA-coated stents. We conclude that low-dose D-24851-eluting polymer-coated stents significantly inhibit neointimal hyperplasia at 28 days through inhibition of proliferation and enhancement of apoptosis. In view of the suboptimal re-endothelialization, longer-term studies are needed in order to establish whether the inhibition of intimal growth is maintained

  17. Development Of An Approach To Modeling Loading And Elution Of Spherical Resorcinol Formaldehyde Ion-Exchange Resin

    International Nuclear Information System (INIS)

    Aleman, S.; Hamm, L.; Smith, F.

    2011-01-01

    The current strategy for removal of cesium from the Hanford waste stream is ion-exchange using spherical Resorcinol-Formaldehyde (sRF) resin. The original resin of choice was granular SuperLig 644 resin and during testing of this resin several operational issues were identified. For example, the granular material had a high angle of internal friction resulting in fragmentation of resin particles along its edges during cycling and adverse hydraulic performance. Efforts to replace SuperLig 644 were undertaken and one candidate was the granular Resorcinol-Formaldehyde (RF) resin where experience with this cation exchanger dates back to the late 1940's. To minimize hydraulic concerns a spherical version of RF was developed and several different chemically produced batches were created. The 5E-370/641 batch of sRF was selected and for the last decade numerous studies have been performed (e.g., batch contact tests, column loading and elution tests). The Waste Treatment Plant (WTP) flowsheet shows that the aqueous phase waste stream will have a wide range of ionic concentrations (e.g., during the loading step 0-3 M free OH, 5+ M Na, 0-1 M K, 0-3 M NO 3 ). Several steps are required in the ion-exchange process to achieve the required Cs separation factors: loading, displacement, washing, elution, and regeneration. The sRF resin will be operated over a wide range in pH (i.e., pH of 12-14 during the loading step and pH of 0.01-1 during the elution step). During some of these steps very high levels of counter-ions and co-ions will be present within the aqueous phase. Alternative process feeds are under consideration as well (e.g., sodium levels as high as 8 M and column operation up to 45 C during loading, reduced and recycled HNO 3 during elution). In order to model the performance of sRF resin through an entire ion-exchange cycle, a more robust isotherm model is required. To achieve this more robust isotherm model requires knowledge of the numbers and kinds of fixed

  18. DEVELOPMENT OF AN APPROACH TO MODELING LOADING AND ELUTION OF SPHERICAL RESORCINOL FORMALDEHYDE ION-EXCHANGE RESIN

    Energy Technology Data Exchange (ETDEWEB)

    Aleman, S.; Hamm, L.; Smith, F.

    2011-10-03

    The current strategy for removal of cesium from the Hanford waste stream is ion-exchange using spherical Resorcinol-Formaldehyde (sRF) resin. The original resin of choice was granular SuperLig 644 resin and during testing of this resin several operational issues were identified. For example, the granular material had a high angle of internal friction resulting in fragmentation of resin particles along its edges during cycling and adverse hydraulic performance. Efforts to replace SuperLig 644 were undertaken and one candidate was the granular Resorcinol-Formaldehyde (RF) resin where experience with this cation exchanger dates back to the late 1940's. To minimize hydraulic concerns a spherical version of RF was developed and several different chemically produced batches were created. The 5E-370/641 batch of sRF was selected and for the last decade numerous studies have been performed (e.g., batch contact tests, column loading and elution tests). The Waste Treatment Plant (WTP) flowsheet shows that the aqueous phase waste stream will have a wide range of ionic concentrations (e.g., during the loading step 0-3 M free OH, 5+ M Na, 0-1 M K, 0-3 M NO{sub 3}). Several steps are required in the ion-exchange process to achieve the required Cs separation factors: loading, displacement, washing, elution, and regeneration. The sRF resin will be operated over a wide range in pH (i.e., pH of 12-14 during the loading step and pH of 0.01-1 during the elution step). During some of these steps very high levels of counter-ions and co-ions will be present within the aqueous phase. Alternative process feeds are under consideration as well (e.g., sodium levels as high as 8 M and column operation up to 45 C during loading, reduced and recycled HNO{sub 3} during elution). In order to model the performance of sRF resin through an entire ion-exchange cycle, a more robust isotherm model is required. To achieve this more robust isotherm model requires knowledge of the numbers and kinds of

  19. Bioresorbable polymer coated drug eluting stent: a model study.

    Science.gov (United States)

    Rossi, Filippo; Casalini, Tommaso; Raffa, Edoardo; Masi, Maurizio; Perale, Giuseppe

    2012-07-02

    In drug eluting stent technologies, an increased demand for better control, higher reliability, and enhanced performances of drug delivery systems emerged in the last years and thus offered the opportunity to introduce model-based approaches aimed to overcome the remarkable limits of trial-and-error methods. In this context a mathematical model was studied, based on detailed conservation equations and taking into account the main physical-chemical mechanisms involved in polymeric coating degradation, drug release, and restenosis inhibition. It allowed highlighting the interdependence between factors affecting each of these phenomena and, in particular, the influence of stent design parameters on drug antirestenotic efficacy. Therefore, the here-proposed model is aimed to simulate the diffusional release, for both in vitro and the in vivo conditions: results were verified against various literature data, confirming the reliability of the parameter estimation procedure. The hierarchical structure of this model also allows easily modifying the set of equations describing restenosis evolution to enhance model reliability and taking advantage of the deep understanding of physiological mechanisms governing the different stages of smooth muscle cell growth and proliferation. In addition, thanks to its simplicity and to the very low system requirements and central processing unit (CPU) time, our model allows obtaining immediate views of system behavior.

  20. Percutaneous Coronary Intervention of Left Main Disease: Pre- and Post-EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) Era.

    Science.gov (United States)

    Park, Duk-Woo; Park, Seung-Jung

    2017-06-01

    For nearly half a century, coronary artery bypass grafting has been the standard treatment for patients with obstructive left main coronary artery (LMCA) disease. However, there has been considerable evolution in the field of percutaneous coronary intervention, and especially, percutaneous coronary intervention for LMCA disease has been rapidly expanded with adoption of drug-eluting stents. Some, but not all randomized trials, have shown that percutaneous coronary intervention with drug-eluting stents might be a suitable alternative for selected patients with LMCA disease instead of bypass surgery. However, none of previous trials involving early-generation drug-eluting stents was sufficiently powered and comparative trials using contemporary drug-eluting stents were limited. Recently, primary results of 2 new trials of EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) were reported. However, these trials showed conflicting results, which might pose uncertainty on the optimal revascularization strategy for LMCA disease. In this article, with the incorporation of a key review on evolution of LMCA treatment, we summarize the similarity or disparity of the EXCEL and NOBLE trials, focus on how they relate to previous trials in the field, and finally speculate on how the treatment strategy may be changed or recommended for LMCA treatment. © 2017 American Heart Association, Inc.

  1. Bioresorbable Everolimus-Eluting Vascular Scaffold for Patients With Peripheral Artery Disease (ESPRIT I): 2-Year Clinical and Imaging Results.

    Science.gov (United States)

    Lammer, Johannes; Bosiers, Marc; Deloose, Koen; Schmidt, Andrej; Zeller, Thomas; Wolf, Florian; Lansink, Wouter; Sauguet, Antoine; Vermassen, Frank; Lauwers, Geert; Scheinert, Dierk; Popma, Jeffrey J; McGreevy, Robert; Rapoza, Richard; Schwartz, Lewis B; Jaff, Michael R

    2016-06-13

    This is the first-in-human study of a drug-eluting bioresorbable vascular scaffold (BVS) for treatment of peripheral artery disease (PAD) involving the external iliac artery (EIA) and superficial femoral artery (SFA). Drug-eluting BVS has shown promise in coronary arteries. The ESPRIT BVS system is a device-drug combination consisting of an everolimus-eluting poly-l-lactide scaffold. Safety and performance were evaluated in 35 subjects with symptomatic claudication. Lesions were located in the SFA (88.6%) and EIA (11.4%). Mean lesion length was 35.7 ± 16.0 mm. The study device was successfully deployed in 100% of cases, without recoil. Procedure-related minor complications were observed in 3 patients (groin hematoma, dissection). Within 2 years there was 1 unrelated death, but no patients in this cohort had an amputation. At 1 and 2 years, the binary restenosis rates were 12.1% and 16.1%, respectively, and target lesion revascularization was performed in 3 of 34 patients (8.8%) and 4 of 32 patients (11.8%), respectively. The ankle brachial index 0.75 ± 0.14 improved from pre-procedure to 0.96 ± 0.16 at 2 years' follow-up. At 2 years, 71.0% of the patients were Rutherford-Becker 0, and 93.5% achieved a maximum walking distance of 1,500 feet. The safety of the ESPRIT BVS was demonstrated with no procedure or device-related deaths or amputations within 2 years. The low occurrence of revascularizations was consistent with duplex-ultrasonography showing sustained patency at 2-years. (A Clinical Evaluation of the Abbott Vascular ESPRIT BVS [Bioresorbable Vascular Scaffold] System [ESPRIT I]; NCT01468974). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Direct elution of sup(99m)Tc complexes from neutron irradiation produced 99Mo incorporated in a MoCl2-MoBr2 mixture

    International Nuclear Information System (INIS)

    Ganzerli Valentini, M.T.; Stella, R.; Genova, N.

    1987-01-01

    A novel type of sup(99m)Tc generator, enabling radiopharmaceutical preparation without reductant addition, was prepared and tested. Neutron activated product 99 Mo, in the form of dichloride cluster, was incorporated into inactive molybdenum dichloride-dibromide mixture (MCB) that was left to settle over an activated alumina layer. Direct elution with aqueous ligands such as salicylate or iminodiacetate derivatives in the pH range 6.5-7.5 yielded chemically stable sup(99m)Tc complexes accompanied by small amounts of secondary products (mostly sup(99m)TcO - 4 ). Pentavalent oxidation state in the salicylate complex and tervalent in the iminodiacetate (IDA) and in the N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetate (HIDA) complexes were assigned to the element after comparison with reference complexes. The anion exchange version of reverse-phase HPLC was used to resolve the eluted product mixture. (author)

  3. Efficient conditions for the elution of poliovirus transferred to activated sludge; Kassei odei ni ikoshita poliovirus no yushutsu joken ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T.; Shiragami, N.; Unno, H. [Tokyo Institute of Technology, Tokyo (Japan); Honda, H. [Nagoya University, Nagoya (Japan). Faculty of Engineering; Yano, K. [Tokyo Metropolitan Research Laboratory of Public Health, Tokyo (Japan)

    1994-08-10

    Enteric virus discharged from human being is treated together with sewage water, but the activated sludge process cannot treat it completely. It is, therefore, important to ascertain its behavior and clarify the treatment criteria. For quantification of virus transferred to the activated sludge phase, the virus is put in a free state by using an adequate eluate to make measurement possible by means of a plaque forming method. This paper discusses the eluate used in this case and its conditions, and obtains the following conclusions: a basic region including neutral region is more effective than acidic region when beef extract is used as an eluate; among the chaotropic salts used, NaNO3 is the most effective, and has a capability of elution in a wide range regardless of pH; and the optimal eluting condition involves a combination of certain amounts of beef extract and NaNO3 that can block the electrostatic actions and hydrophobic interactions between the activated sludge and the virus. 20 refs., 7 figs., 3 tabs.

  4. Stent thrombosis, myocardial infarction, and death after drug-eluting and bare-metal stent coronary interventions

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Kaltoft, Anne

    2007-01-01

    OBJECTIVES: The aim of the study was to examine outcomes subsequent to implantation of drug-eluting stents (DES) and bare-metal stents (BMS). BACKGROUND: Use of DES might be associated with increased risk of stent thrombosis (ST), myocardial infarction (MI), and death. METHODS: From January 2002...... through June 2005, data from all percutaneous coronary interventions in western Denmark were prospectively recorded in the Western Denmark Heart Registry; 12,395 consecutive patients (17,152 lesions) treated with stent implantation were followed for 15 months. Data on death and MI were ascertained from...... within 15 months after implantation of DES seems unlikely to outweigh the benefit of these stents. Udgivelsesdato: 2007-Jul-31...

  5. Use of FTA elute card impregnated with cervicovaginal sample directly into the amplification reaction increases the detection of human papillomavirus DNA.

    Science.gov (United States)

    Santos, Carla R; Franciscatto, Laura G; Barcellos, Regina B; Almeida, Sabrina E M; Rossetti, Maria Lucia R

    2012-01-01

    This study aimed to evaluate the use of the FTA elute card(TM) impregnated with cervicovaginal sample directly in the PCR amplification for detection of HPV-DNA. The results were compared to a reference technique. This method was more efficient than the protocol indicated by the manufacturer, identifying 91.7% against 54.2% of the positive samples.

  6. Use of FTA elute card impregnated with cervicovaginal sample directly into the amplification reaction increases the detection of human papillomavirus DNA

    OpenAIRE

    Santos, Carla R.; Franciscatto, Laura G.; Barcellos, Regina B.; Almeida, Sabrina E. M; Rossetti, Maria Lucia R.

    2012-01-01

    This study aimed to evaluate the use of the FTA elute cardTM impregnated with cervicovaginal sample directly in the PCR amplification for detection of HPV-DNA. The results were compared to a reference technique. This method was more efficient than the protocol indicated by the manufacturer, identifying 91.7% against 54.2% of the positive samples.

  7. DMSO inhibits human platelet activation through cyclooxygenase-1 inhibition. A novel agent for drug eluting stents?

    International Nuclear Information System (INIS)

    Asmis, Lars; Tanner, Felix C.; Sudano, Isabella; Luescher, Thomas F.; Camici, Giovanni G.

    2010-01-01

    Background: DMSO is routinely infused together with hematopoietic cells in patients undergoing myeloablative therapy and was recently found to inhibit smooth muscle cells proliferation and arterial thrombus formation in the mouse by preventing tissue factor (TF), a key activator of the coagulation cascade. This study was designed to investigate whether DMSO prevents platelet activation and thus, whether it may represent an interesting agent to be used on drug eluting stents. Methods and results: Human venous blood from healthy volunteers was collected in citrated tubes and platelet activation was studied by cone and platelet analyzer (CPA) and rapid-platelet-function-assay (RPFA). CPA analysis showed that DMSO-treated platelets exhibit a lower adherence in response to shear stress (-15.54 ± 0.9427%, n = 5, P < 0.0001 versus control). Additionally, aggregometry studies revealed that DMSO-treated, arachidonate-stimulated platelets had an increased lag phase (18.0% ± 4.031, n = 9, P = 0.0004 versus control) as well as a decreased maximal aggregation (-6.388 ± 2.212%, n = 6, P = 0.0162 versus control). Inhibitory action of DMSO could be rescued by exogenous thromboxane A2 and was mediated, at least in part, by COX-1 inhibition. Conclusions: Clinically relevant concentrations of DMSO impair platelet activation by a thromboxane A2-dependent, COX-1-mediated effect. This finding may be crucial for the previously reported anti-thrombotic property displayed by DMSO. Our findings support a role for DMSO as a novel drug to prevent not only proliferation, but also thrombotic complications of drug eluting stents.

  8. Study of plutonium IV elution from macromolecular anion exchange resin by 0.5 M nitric acid

    International Nuclear Information System (INIS)

    Nadkarni, M.N.; Mayankutty, P.C.; Pillai, N.S.; Shinde, S.S.

    1976-01-01

    Preliminary studies indicated that macroreticular resins possess more or less the same capacities and absorption characteristics for thorium, uranium and plutonium from nitric acid solutions as the conventional resins. Detailed studies were, then, conducted. It was found that Pu(IV) can be loaded on the macroreticular anion exchange resin, Amberlyst A-26 from 7.2 M nitric acid in much the same way as Dowex 1x4. It was also observed that the elution of Pu(IV) from Amberlyst A-26 by 0.5 M nitric acid is much more rapid and quantitative than from Dowex 1x4. (author)

  9. Novel Route for Agmatine Catabolism in Aspergillus niger: 4-Guanidinobutyrase Assay.

    Science.gov (United States)

    Saragadam, Tejaswani; Punekar, Narayan S

    2018-01-01

    The enzyme 4-guanidinobutyrase (GBase) catalyzes the hydrolysis of 4-guanidinobutyric acid (GB) to 4-aminobutyric acid (GABA) and urea. Here we describe methods to estimate urea and GABA that were suitably adapted from the published literature. The urea is determined by colorimetric assay using modified Archibald's method. However, the low sensitivity of this method often renders it impractical to perform fine kinetic analysis. To overcome this limitation, a high sensitive method for detecting GABA is exploited that can even detect 1 μM of GABA in the assay mixture. The samples are deproteinized by perchloric acid (PCA) and potassium hydroxide treatment prior to HPLC analysis of GABA. The method involves a pre-column derivatization with o-phthalaldehyde (OPA) in combination with the thiol 3-mercaptopropionic acid (MPA). The fluorescent GABA derivative is then detected after reversed phase high performance liquid chromatography (RP-HPLC) using isocratic elution. The protocols described here are broadly applicable to other biological samples involving urea and GABA as metabolites.

  10. Determination of sildenafil mixed into herbal honey mixture by ultra-performance liquid chromatography-quadrupole time of flight mass spectrometry

    Directory of Open Access Journals (Sweden)

    Neira Mustabasic

    2017-01-01

    Full Text Available There has been a number of reports of natural products contaminated with illegal adulterants that threaten consumer health because of their adverse pharmacological effects worldwide. In this study, a multi-residual ultra-performance liquid chromatography method with quadrupole time-of-flight mass spectrometry (UPLC-QTOF-MS was applied for the identification of sildenafil added into a herbal honey mixture used as an immune system booster. Electrospray ionization (ESI source was applied and operated in the positive ion mode. The mobile phase consisted of 0.1% formic acid aqueous solution/acetonitrile (70:30, v/v using the isocratic gradient elution system at a detection wavelength of 290 nm. The compound of sildenafil added into traditional herbal mixed honey was identified according to the spectrum, chromatographic behavior, and mass spectral data were identified by comparison with the reference substance. The method is selective, sensitive and can be used to detect the sildenafil illegally added into traditional herbal medicinal preparations.

  11. Determination of itopride in human plasma by liquid chromatography coupled to tandem mass spectrometric detection: application to a bioequivalence study.

    Science.gov (United States)

    Lee, Heon-Woo; Seo, Ji-Hyung; Choi, Seung-Ki; Lee, Kyung-Tae

    2007-01-30

    A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5>166.1 for itopride and m/z 342.3>111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2=0.9999) over the studied range (0.5-1000 ng mL(-1)) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.

  12. Liquid chromatographic determination with fluorescence detection of B6 vitamers and riboflavin in milk and pharmaceuticals

    International Nuclear Information System (INIS)

    Gatti, R.; Gioia, M.G.

    2005-01-01

    A simple, reliable and selective high performance liquid chromatographic method with fluorescence detection at different programmed wavelengths has been developed for the simultaneous analysis of B 6 vitamers (pyridoxal 5'-phosphate, 4-pyridoxic acid, pyridoxal, pyridoxine and pyridoxamine) and Vitamin B 2 in commercial vitaminized milk and in woman milk. The chromatographic separations were performed on a reversed phase octyl column by using a mobile phase consisting of sodium pentanesulfonate in 1% acetic acid-methanol-tetrahydrofuran under gradient elution conditions. The fluorescence intensity of pyridoxal 5'-phosphate was enhanced by post-column photochemical conversion, giving significantly different fluorescence spectra by a on-line photoreactor switched OFF and ON under irradiation at 254 nm. In addition, a simple and rapid method in isocratic conditions without the need of photochemical conversion was proposed for the analysis of Vitamin B 6 and Vitamin B 2 in pharmaceuticals. Linearity, precision, recovery, selectivity and sensitivity were found satisfactory for each analysed compound. Quantitation limits ranged from 26 to 240 fmol

  13. Development and validation of a high-performance liquid chromatography method for the quantification of talazoparib in rat plasma: Application to plasma protein binding studies.

    Science.gov (United States)

    Hidau, Mahendra Kumar; Kolluru, Srikanth; Palakurthi, Srinath

    2018-02-01

    A sensitive and selective RP-HPLC method has been developed and validated for the quantification of a highly potent poly ADP ribose polymerase inhibitor talazoparib (TZP) in rat plasma. Chromatographic separation was performed with isocratic elution method. Absorbance for TZP was measured with a UV detector (SPD-20A UV-vis) at a λ max of 227 nm. Protein precipitation was used to extract the drug from plasma samples using methanol-acetonitrile (65:35) as the precipitating solvent. The method proved to be sensitive and reproducible over a 100-2000 ng/mL linearity range with a lower limit of quantification (LLQC) of 100 ng/mL. TZP recovery was found to be >85%. Following analytical method development and validation, it was successfully employed to determine the plasma protein binding of TZP. TZP has a high level of protein binding in rat plasma (95.76 ± 0.38%) as determined by dialysis method. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Enantioselective analysis of citalopram and demethylcitalopram in human whole blood by chiral LC-MS/MS and application in forensic cases

    DEFF Research Database (Denmark)

    Johansen, Sys Stybe

    2017-01-01

    OH. The analytes were separated on a 250 x 4.6 mm Chirobiotic V, 5 µm column by isocratic elution with methanol:ammonia:acetic acid (1000:1:1) using an ultra-high-pressure liquid chromatography (UHPLC) system. Quantification was performed by tandem mass spectrometry (MS/MS) using multiple reaction monitoring...... in the positive mode. The total chromatographic run time was 20 min. The limit of detection (LOD) and quantification (LOQ) were 0.001 and 0.005 mg/kg of all four enantiomers, respectively. Linear behaviour was obtained for all four enantiomers from LOQ to 0.50 mg/kg blood with absolute recoveries from 71 to 80......%. The method showed an acceptable precision and accuracy as the obtained coefficient of variation, and bias values were ≤ 16% for all enantiomers. After the validation of the method, a correlation with the racemic method was assessed and found to be acceptable. Then, the method was successfully applied...

  15. Stability indicating RP-LC-PDA method for the quantitative analysis of saxagliptin in pharmaceutical dosage form

    Directory of Open Access Journals (Sweden)

    Laís Engroff Scheeren

    2015-06-01

    Full Text Available Saxagliptin is a potent and selective inhibitor of the enzyme dipeptidyl peptidase 4. It is effective in the treatment of type 2 diabetes mellitus because it stimulates the pancreas to produce insulin. In the present study, a liquid chromatography method was developed and validated to quantify the drug in tablets. This method was based on the isocratic elution of saxagliptin, using a mobile phase consisting of 0.1% phosphoric acid at pH 3.0 - methanol (70: 30, v/v at a flow rate of 1 mL.min-1 with UV detection at 225 nm. The chromatographic separation was achieved in 8 minutes on a Waters XBridge C18 column (250 mm x 4.6 mm, 5µm maintained at ambient temperature. The proposed method proved to be specific and robust for the quality control of saxagliptin in pharmaceutical dosage forms, showing good linearity in the range of 15.0 - 100.0 µg.mL-1 (r>0.999, precision (RSD

  16. An improved high-performance liquid chromatographic method for simultaneous determination of tocopherols, tocotrienols and γ-oryzanol in rice.

    Science.gov (United States)

    Huang, Shao-Hua; Ng, Lean-Teik

    2011-07-22

    An improved normal phase high performance liquid chromatographic (NP-HPLC) method was developed for simultaneous quantification of eight vitamin E isomers (α-, β-, γ- and δ-tocopherols and α-, β-, γ- and δ-tocotrienols) and γ-oryzanol in rice. A complete separation of all compounds was achieved within 25 min using an Inertsil CN-3, SIL-100A 5 μM (4.6 mm × 250 mm) column and an isocratic elution system of hexane/isopropanol/ethylacetate/acetic acid (97.6:0.8:0.8:0.8, v/v/v/v) at a flow rate varying from 0.7 to 1.5 mL min(-1). A linear correlation coefficient (r(2)>0.99) and high reproducibility were obtained at concentrations ranging 0.05-10 μg mL(-1) for vitamin E isomers and 0.5-500 μg mL(-1) for γ-oryzanol. This method proved to be rapid, accurate and reproducible. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. An HPLC method for determination of azadirachtin residues in bovine muscle.

    Science.gov (United States)

    Gai, María Nella; Álvarez, Christian; Venegas, Raúl; Morales, Javier

    2011-04-01

    A high-performance liquid chromatography (HPLC) method for the determination of azadirachtin (A and B) residues in bovine muscle has been developed. Azadirachtin is a neutral triterpene and chemotherapeutic agent effective in controlling some pest flies in horses, stables, horns and fruit. The actual HPLC method uses an isocratic elution and UV detection. Liquid-liquid extraction and solid-phase purification was used for the clean-up of the biological matrix. The chromatographic determination of these components is achieved using a C18 analytical column with water-acetonitrile mixture (27.5:72.5, v/v) as mobile phase, 1 mL/min as flow rate, 45 °C column temperature and UV detector at 215 nm. The azadirachtin peaks are well resolved and free of interference from matrix components. The extraction and analytical method developed in this work allows the quantitation of azadirachtin with precision and accuracy, establishing a lower limit of quantitation of azadirachtin, extracted from the biological matrix.

  18. Brain concentrations of benzodiazepines are elevated in an animal model of hepatic encephalopathy

    International Nuclear Information System (INIS)

    Basile, A.S.; Pannell, L.; Jaouni, T.; Gammal, S.H.; Fales, H.M.; Jones, E.A.; Skolnick, P.

    1990-01-01

    Brain extracts from rats with hepatic encephalopathy due to thioacetamide-induced fulminant hepatic failure contained 4- to 6-fold higher concentrations of substances that inhibit radioligand binding to benzodiazepine receptors than corresponding control rat extracts. Both isocratic and gradient-elution HPLC indicated that this inhibitory activity was localized in 3-8 peaks with retention times corresponding to deschlorodiazepam, deschlorolorazepam, lorazepam, oxazepam, diazepam, and N-desmethyldiazepam. The presence of diazepam and N-desmethyldiazepam was confirmed by mass spectroscopy. Both mass spectroscopic and radiometric techniques indicated that the concentrations of N-desmethyldiazepam and diazepam in brain extracts from encephalopathic rats were 2-9 and 5-7 times higher, respectively, than in control brain extracts. While benzodiazepines have been identified previously in mammalian and plant tissues, this report demonstrates that concentrations of these substances are increased in a pathophysiological condition. These findings provide a rational basis for the use of benzodiazepine receptor antagonists in the management of hepatic encephalopathy in humans

  19. LC-ESI-MSD fast determination of residual mitomycin C in hen aqueous humour after corneal refractive surgery.

    Science.gov (United States)

    Nozal, M J; Bernal, J L; Martín, M T; Bernal, J; Torres, R M; Merayo, J

    2006-01-23

    A simple, fast and reliable method has been developed for the assay of traces of mitomycin C (MMC) in hen aqueous humour samples. The determination was carried out by high-performance liquid chromatography with electrospray ionization mass spectrometric detection. In isocratic elution analysis, the mobile phase was a mixture of water-acetonitrile (78:22, v/v) and the chromatographic column was C(18) at 35 degrees C. The method has been validated over a range from 0.1 to 250 microg L(-1) in hen aqueous humour with correlation coefficients higher than 0.999. Limit of detection and limit of quantification for MMC based in signal to noise ratio of 3 and 10, respectively, were 20 and 71 ng L(-1). The developed method allows the analysis of MMC in hen aqueous humour samples obtained at different times and conditions in order to evaluate and compare the efficacy of the drug administration.

  20. Coronary Artery Bypass Surgery Versus Drug-Eluting Stent Implantation for Left Main or Multivessel Coronary Artery Disease A Meta-Analysis of Individual Patient Data

    NARCIS (Netherlands)

    Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W.; Park, Seung-Jung

    2016-01-01

    OBJECTIVES The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD).

  1. Comparison of Outcomes in Patients With Versus Without Diabetes Mellitus After Revascularization With Everolimus- and Sirolimus-Eluting Stents (from the SORT OUT IV Trial)

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Junker, Anders

    2012-01-01

    Diabetes is associated with increased risk of major adverse cardiac events (MACEs) after percutaneous coronary intervention. The purpose of this substudy of the SORT OUT IV trial was to compare clinical outcomes in patients with and without diabetes mellitus treated with everolimus-eluting stents...... (EESs) or sirolimus-eluting stents (SESs). In total 2,774 patients (390 with diabetes, 14.1%) were randomized to stent implantation with EESs (n = 1,390, diabetes in 14.0%) or SESs (n = 1,384, diabetes in 14.2%). Randomization was stratified by presence/absence of diabetes. The primary end point...... was MACEs, a composite of cardiac death, myocardial infarction, definite stent thrombosis, or target vessel revascularization within 18 months. MACEs were higher in diabetic than in nondiabetic patients (13.1% vs 6.4%, hazard ratio [HR] 2.08, 95% confidence interval [CI] 1.51 to 2.86). In diabetic patients...

  2. Successful drug-eluting stent implantation in a male patient with dextrocardia: a case report

    Directory of Open Access Journals (Sweden)

    Long Wenjie

    2017-12-01

    Full Text Available Situs inversus with dextrocardia is a rare condition, with complete transposition of all the body organs, including the heart. Percutaneous coronary intervention (PCI in these patients is technically difficult because of the mirror image of organs. Here, we describe a 56-year-old man with coronary heart disease with known situs inversus with dextrocardia and coronary percutaneous intervention was performed for stenosis in the right coronary artery. A drug eluting stent was implanted at this site successfully. This case suggested that the interventional management of such patients follows the same general rules as for non-dextrocardia patients, but the manipulation of the catheter and projection position choices need to be taken into consideration to obtain optimal benefits for the patient.

  3. Determination of hexavalent chromium concentration in industrial waste incinerator stack gas by using a modified ion chromatography with post-column derivatization method.

    Science.gov (United States)

    Miyake, Yuichi; Tokumura, Masahiro; Iwazaki, Yuta; Wang, Qi; Amagai, Takashi; Horii, Yuichi; Otsuka, Hideyuki; Tanikawa, Noboru; Kobayashi, Takeshi; Oguchi, Masahiro

    2017-06-16

    An ion chromatography with post-column derivatization with 1,5-diphenylcarbazide (IC-DPC) analytical method was modified to enable measurement of trace-level hexavalent chromium (Cr(VI)) in air. One of the difficulties in determining trace levels of Cr(VI) in air with conventional IC-DPC methods is co-elution of the solvent and ion peaks due to high concentrations of ionic compounds in the extract. However, by using gradient elution rather than isocratic elution we were able to fully resolve the Cr(VI) ion peak from the solvent peak without the need for diluting the extract, which would have reduced the minimum quantifiable level of the method. With this method, we were able to detect Cr(VI) in air at concentrations of 5.3ng/m 3 (assuming a sampling volume of 1m 3 and a final solution volume of 10mL). Recovery tests at three different concentrations of Cr(VI) (50, 250, 1000ng) were performed with or without fly ash; recovery rates at all the concentrations of Cr(VI), with or without fly ash, ranged from 68% to 110% (mean±relative standard deviation, 96%±11%), and there were no differences in recovery rates with respect to the presence or absence of fly ash. Finally, we used the developed method to determine the concentration of Cr(VI) in stack gases collected from eight industrial waste incinerators located in Japan. The concentration of Cr(VI) in the stack gases ranged from below the method quantification limit to 3100ng/m 3 . The highest concentrations of Cr(VI) detected in the stack gases were two to three orders of magnitude higher than that in ambient air in Japan. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Next generation drug-eluting stents: focus on bioabsorbable platforms and polymers

    Directory of Open Access Journals (Sweden)

    Brendan Doyle

    2009-11-01

    Full Text Available Brendan Doyle, David R Holmes JrDivision of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic College of Medicine, Rochester, Minnesota, USAAbstract: The success of drug-eluting stents in preventing restenosis has shifted the focus of new stent development toward enhancing long term safety and efficacy of these devices, while simultaneously eliminating the need for indefinite dual antiplatelet therapy. A technical advance fulfilling these aims would hold tremendous potential to reduce morbidity, mortality and economic costs associated with the percutaneous treatment of coronary artery disease. An attractive approach is the use of bioabsorbable stent designs. These may include stents with different bioabsorbable drugs, bioabsorbable polymers or even bioabsorbable metallic backbones. A device that could achieve excellent acute and long-term results, but disappear completely within months (thereby avoiding the need for prolonged dual antiplatelet therapy, would be a tremendous advance. Too good to be true? We explore here the scientific rationale and prospects for success with this exciting concept.Keywords: percutaneous coronary intervention, biodegradable, bioabsorbable, polymer, stent

  5. Use of FTA elute card impregnated with cervicovaginal sample directly into the amplification reaction increases the detection of human papillomavirus DNA

    Directory of Open Access Journals (Sweden)

    Carla R. Santos

    2012-03-01

    Full Text Available This study aimed to evaluate the use of the FTA elute cardTM impregnated with cervicovaginal sample directly in the PCR amplification for detection of HPV-DNA. The results were compared to a reference technique. This method was more efficient than the protocol indicated by the manufacturer, identifying 91.7% against 54.2% of the positive samples.

  6. Irinotecan drug eluting beads used as a treatment of advanced intra hepatic cholangiocarcinoma

    Directory of Open Access Journals (Sweden)

    Jean Amede Roch

    2008-10-01

    Full Text Available

    This report describes a 74-year-old male with unresectable intrahepatic cholangiocarcinoma (ICC. However surgical procedure is the only curative treatment, it often seems to be ineffective because of the aggressive behaviour of the disease. The role of systemic chemotherapy in the ICC is undefined with a median survival between 6.43 to 12.17 months obtained by using the combination chemotherapy of gemcitabine with cisplatin. In the present case, we performed a targeted treatment using drug eluting beads (DEB with irinotecan (IRI administered as transarterial-chemoembolization (TACE. After one session, the tumour vascularity decreased significantly at the one month evaluation on computed tomography (CT scan of the liver.  This case report suggested that minimally invasive transcatheter DEB embolization could be a promising, safe and effective treatment for selective patients with unresectable ICC.

  7. In Vivo and In Vitro Elution of Analgesics from Multilayered Poly(D,L)-lactide-co-glycolide Nanofibers Incorporated Ureteral Stents

    OpenAIRE

    Lin, Yi-Chia; Liu, Kuo-Sheng; Lee, Demei; Li, Min-Jhan; Liu, Shih-Jung; Ito, Hiroshi

    2018-01-01

    We develop novel analgesic-eluting nanofiber-incorporated ureteral stents that offer sustained release of lidocaine and ketorolac for local drug delivery. Lidocaine and poly(D,L)-lactide-co-glycolide (PLGA) were dissolved in hexafluoroisopropanol and were electrospun into nonwoven nanofibers onto the surface of ureteral stents. This was followed by electrospinning of another layer of PLGA nanofibers containing ketorolac. Electrospun drug-loaded nanofibers were then characterized using scannin...

  8. The Role Of Inflammation In Stent Restenosis More Than 1 Year Afetr Drug Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Hasan Shemirani

    2011-09-01

    Full Text Available Background: In stent restenosis (ISR following endovascular interventions is the main limitation of their long-term success. Despite advances have been made during recent years to decrease restenosis, it remains a challenging clinical problem.The aim of this study was to evaluate the relationship between angiographic coronary in stent restenosis, inflammation after successful stent implantation. Methods: This study included 78 patients, 35year old and higher who underwent coronary angiography more than 1 year after drug-eluting stent (DES implantation because of symptoms suggestive ischemia. Patients were divided into ISR group (case and patent stent group (control according to angiography results. For all patients blood lipids and high sensitivity C-Reactive Protein (hsCRP were measured simultaneously. Results: Age, sex, hypertension, current smoking, and lipid profile other than High Density Lipoprotein (HDL-C of patients in the case and control groups were similar .However, HDL-C < 40mg/L was more prevalent with ISR (66.7% vs. 30.8%, p=0.002. The hsCRP level was 2.98±2.06 mg/L in the case group and 2.50±1.80 mg/L in the control group. There were no significant differences in mean hsCRP concentration between the two groups (p=0.14, however mean hsCRP level was significantly higher in men of case group than control group (3.35mg/L vs. 2.21mg/L, p<0.05. Conclusion: This study demonstrates that in men but not in women inflammation may be a predictor of in stent restenosis more than 1 year after drug eluting stent implantation. Also, high-density lipoprotein (HDL probably has protective effect against stent restenosis.

  9. Research on deeply purifying effluent from uranium mining and metallurgy to remove uranium by ion exchange. Pt.2: Elution uranium from lower loaded uranium resin by the intense fractionation process

    International Nuclear Information System (INIS)

    Zhang Jianguo; Chen Shaoqiang; Qi Jing

    2002-01-01

    Developing macroporous resin for purifying uranium effluent from uranium mining and metallurgy is presented. The Intense Fractionation Process is employed to elute uranium from lower loaded uranium resin by the eluent of sulfuric acid and ammonium sulfate. The result is indicated that the uranium concentration in the rich elutriant is greatly increased, and the rich liquor is only one bed column volume, uranium concentration in the elutriant is increased two times which concentration is 10.1 g/L. The eluent is saved about 50% compared with the conventional fixed bed elution operation. And also the acidity in the rich elutriant is of benefit to the later precipitation process in uranium recovery

  10. [Effectiveness of FTA Elute® indicating cartridge in combination with hybrid capture 2 for cervical cancer screening].

    Science.gov (United States)

    Chen, Feng; Zhang, Xi; Wang, Shaoming; Hu, Shangying; Chen, Wen; Zhao, Fanghui; He, Wei; Zhang, Yuqing; Qiao, Youlin

    2015-02-01

    To evaluate the effectiveness of FTA Elute® Cartridge (GE healthcare, Kent, UK) in combination with hybrid capture 2 (HC2) testing for cervical cancer screening. From May to June 2012, 412 women aged 25 to 65 years in Jiangxi Tonggu were enrolled in the study. We used pathological outcome as the gold standard, and the accuracy of the FTA card in combination with HC2 testing was investigated from both physician- and self-sampling, respectively. Physician sampling using the FTA card in combination with HC2 testing showed a comparable sensitivity (12/13) with the liquid based medium, but a higher specificity 69.5% (266/383) vs (77.8%, 298/383) (P FTA card in combination with HC2 testing with liquid based medium was 10/13 vs 8/13(P = 0.625) and (62.3%, 238/382) vs (75.7%, 289/382) (P FTA and liquid-based sampling medium was 86.1% (340/395) and 79.5% (314/395). For physician-collected samples used for HC2 testing to detect CIN2+, the accuracy of the FTA card was superior to that of the liquid-based medium (area under the receiver operating characteristic curve (AUC) = 0.898, 95%CI:0.838-0.958). FTA Elute® cartridge in combination with HC2 testing is a promising method of specimen transport for cervical cancer screening programs with a good precision.With further optimization, it could become an effective method for cervical cancer screening in various economic levels of areas.

  11. Rapid sensitive validated UPLC–MS method for determination of venlafaxine and its metabolite in rat plasma: Application to pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Dubey

    2013-12-01

    Full Text Available A new ultra-performance liquid chromatography–electrospray ionization mass spectrometry (UPLC–MS/ESI method for simultaneous determination of venlafaxine (VEN and its metabolite O-desmethylvenlafaxine (ODV in rat plasma has been developed and validated using Venlafaxine d6 as the internal standard. The compounds and internal standard were extracted from plasma by solid phase extraction. The UPLC separation of the analytes was performed on ACQUITY UPLC® BEH Shield RP18 (1.7 µm, 100 mm×2.1 mm column, using isocratic elution with mobile phase constituted of water (containing 2 mM ammonium acetate: acetonitrile (20:80, v/v at a flow rate of 0.3 mL/min. All of the analytes were eluted within 1.5 min. The compounds were ionized in the electrospray ionization (ESI ion source of the mass spectrometer, operating in multiple reaction monitoring (MRM and positive ion mode. The precursor to product ion transitions monitored for VEN, ODV and Venlafaxine d6 were m/z 278.3→121.08, 264.2→107.1 and 284.4→121.0, respectively. The developed and validated method was used for the pharmacokinetic study of VEN in rats. Keywords: Venlafaxine, O-desmethylvenlafaxine, Metabolite, UPLC–MS/ES

  12. ANALYSIS OF DRUG-PROTEIN BINDING BY ULTRAFAST AFFINITY CHROMATOGRAPHY USING IMMOBILIZED HUMAN SERUM ALBUMIN

    Science.gov (United States)

    Mallik, Rangan; Yoo, Michelle J.; Briscoe, Chad J.; Hage, David S.

    2010-01-01

    Human serum albumin (HSA) was explored for use as a stationary phase and ligand in affinity microcolumns for the ultrafast extraction of free drug fractions and the use of this information for the analysis of drug-protein binding. Warfarin, imipramine, and ibuprofen were used as model analytes in this study. It was found that greater than 95% extraction of all these drugs could be achieved in as little as 250 ms on HSA microcolumns. The retained drug fraction was then eluted from the same column under isocratic conditions, giving elution in less than 40 s when working at 4.5 mL/min. The chromatographic behavior of this system gave a good fit with that predicted by computer simulations based on a reversible, saturable model for the binding of an injected drug with immobilized HSA. The free fractions measured by this method were found to be comparable to those determined by ultrafiltration, and equilibrium constants estimated by this approach gave good agreement with literature values. Advantages of this method include its speed and the relatively low cost of microcolumns that contain HSA. The ability of HSA to bind many types of drugs also creates the possibility of using the same affinity microcolumn to study and measure the free fractions for a variety of pharmaceutical agents. These properties make this technique appealing for use in drug binding studies and in the high-throughput screening of new drug candidates. PMID:20227701

  13. High performance liquid chromatography--atomic fluorescence spectrometric determination of arsenic species in beer samples

    International Nuclear Information System (INIS)

    Melo Coelho, N.M.; Parrilla, Carmen; Cervera, M.L.; Pastor, A.; Guardia, M. de la

    2003-01-01

    A method has been developed for the direct determination of As(III), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and As(V) in beers by hydride generation--atomic fluorescence spectrometry after separation of arsenic species by high performance liquid chromatography. Compounds were separated by anion-exchange chromatography with isocratic elution using KH 2 PO 4 /K 2 HPO 4 as mobile phase with elution times of 1.67, 2.08, 6.52 and 10.72 min for As(III), DMA, MMA and As(V), respectively. Parameters affecting the hydride generation of all arsenic species were studied and the best conditions were established as a reaction coil of 150 cm, for a sample injected volume of 100 μl, a 4.0% (m/v) solution of sodium tetrahydroborate and 2.0 mol l -1 hydrochloric acid with flow rates of 2.7 and 1.7 ml min -1 , respectively and a flow rate of 500 ml min -1 for the argon carrier gas. Under the best experimental conditions, the detection limit was found to be 0.12, 0.20, 0.27 and 0.39 μg l -1 for As(III), DMA, MMA and As(V), respectively. The relative standard deviation for eight independent determinations varied from 3.9 till 8.9% for species considered at a concentration level of 10.0 μg l -1 . Recovery and comparative studies evidenced that the method is suitable for the accurate determination of arsenic species in water and beer samples

  14. Single-laboratory validation of a high-performance liquid chromatographic-diode array detector-fluorescence detector/mass spectrometric method for simultaneous determination of water-soluble vitamins in multivitamin dietary tablets.

    Science.gov (United States)

    Chen, Pei; Atkinson, Renata; Wolf, Wayne R

    2009-01-01

    The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 microm, 250 x 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLDIMS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.

  15. Determination of pharmaceutical and illicit drugs in oral fluid by ultra-high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Di Corcia, D; Lisi, S; Pirro, V; Gerace, E; Salomone, A; Vincenti, M

    2013-05-15

    A simple and extremely fast procedure for the quantitative determination in oral fluid samples of 44 substances, including the most common drugs of abuse and several pharmaceutical drugs, was developed and fully validated. Preliminary sample treatment was limited to protein precipitation. The resulting acetonitrile solution was directly injected into an ultra-high performance liquid chromatograph (UHPLC) equipped with a C18 column (100mm×2.1mm, 1.7μm). The mobile phase eluted with linear gradient (water/formic acid 5mM: acetonitrile/formic acid 5mM; v:v) from 98:2 to 0:100 in 5.0min, followed by isocratic elution at 100% B for 1.0min. The flow rate was 0.6mL/min and the total run time was 9.0min including re-equilibration at the initial conditions. The analytes were revealed by a triple quadrupole mass spectrometer operating in the selected reaction monitoring mode. The method proved to be simple, accurate, rapid and highly sensitive, allowing the simultaneous detection of all compounds. The ease of sample treatment, together with the wide range of detectable substances, all with remarkable analytical sensitivity, make this procedure ideal for the screening of large populations in several forensic and clinical contexts, whenever oral fluid sampling has to be preferred to blood sampling, as for example in short retrospective investigations. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. The effect of modulators of radiation-induced G2 arrest on the repair of radiation-induced DNA damage detectable by neutral filter elution

    International Nuclear Information System (INIS)

    Rowley, R.; Kort, L.

    1988-01-01

    The influence of cycloheximide (50 μg/ml), caffeine (5 mM) and cordycepin (0.15 mM) on the repair of the damage detectable in DNA by neutral filter elution was determined. Chinese hamster ovary cells (CHO) were irradiated with X-ray doses of 20, 60 and 100 Gy then allowed to repair without drug treatment or in the presence of each drug for intervals up to 6 h. DNA damage repair proceeded in two phases. The fast component of the repair process (t 1/2 approx. 7 min) was not modified by drug treatment; the slow component (t 1/2 170 min) was unaffected by cycloheximide or cordycepin, but appeared to be inhibited by caffeine. It was concluded that: (a) the lesion which results in radiation-induced G 2 arrest is not the lesion which is detectable by neutral filter elution, and (b) the influence of caffeine on dsb repair is specific to caffeine and is not mediated by a reduction in the duration of G 2 arrest. (author)

  17. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis. From western denmark heart registry

    DEFF Research Database (Denmark)

    Jensen, Jesper; Jensen, Lisette Okkels; Terkelsen, Christian Juhl

    2012-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  18. Detection of enteropathogens associated with travelers’ diarrhea using a multiplex Luminex-based assay performed on stool samples smeared on Whatman FTA Elute cards

    Science.gov (United States)

    Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R

    2015-01-01

    We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman FTA Elute cards smeared with stool containing pathogens associated with travelers’ diarrhea. LoDs ranged between 102-105 CFU, PFU or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoD increased with prolonged storage of cards. PMID:26072151

  19. Determinação de compostos fenólicos por cromatografia líquida de alta eficiência isocrática durante estacionamento da erva-mate Determination of phenolic compounds by isocratic high performance liquid chromatografic method during storage of yerba-mate

    Directory of Open Access Journals (Sweden)

    Fabiana L. Goularte Dutra

    2010-01-01

    Full Text Available Different phenolic compound, 5- caffeoylquinic acid (5-CQA, caffeic acid (AC and rutin (Ru contents of yerba-mate (Ilex paraguariensis Brazilian samples of 06 different regions of São Mateus - Paraná, during natural and accelerated industrial storage, were evaluated. For quantification, a reverse phase HPLC isocratic method was developed and validated using methanol:water (35:65 v/v acidified with 0.5% acetic acid as mobile phase and a photodiode array detector. The six sample global average contents were (34.90 and 36.10 mg g-1 for 5-CQA, (0.18 mg g-1 and 0.23 mg g-1 for AC and (7.12 and 7.18 mg g-1 for Ru, respectively, for the natural and accelerated storage systems. The results showed that the 5-CQA and Ru content are kept constant during the storage while AC content increase only during accelerated storage.

  20. Impact of Hemoglobin A1c Levels on Residual Platelet Reactivity and Outcomes After Insertion of Coronary Drug-Eluting Stents (from the ADAPT-DES Study)

    DEFF Research Database (Denmark)

    Schoos, Mikkel M.; Dangas, George D.; Mehran, Roxana

    2016-01-01

    An increasing hemoglobin A1c (HbA1c) level portends an adverse cardiovascular prognosis; however, the association between glycemic control, platelet reactivity, and outcomes after percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is unknown. We sought to investigate whether Hb...... With Drug Eluting Stents registry, HbA1c levels were measured as clinically indicated in 1,145 of 8,582 patients, stratified by HbA1c 8.5% (n = 171, 14.9%). HPR on clopidogrel and aspirin was defined after PCI as P2Y12 reaction units (PRU) >208...... >208 (42.5%, 50.2%, and 62.3%, p definite or probable stent thrombosis (ST; 0.9%, 2.7%, and 4.2%, p = 0.02) increased progressively with HbA1c groups. Clinically relevant bleeding was greatest in the intermediate HbA1c group (8.2% vs 13.1% vs 9.5%, p = 0.04). In adjusted models...