WorldWideScience

Sample records for iso valve branch

  1. A study of ISO Solenoid Valve with static and dynamic characteristics

    International Nuclear Information System (INIS)

    Jeon, Y. S.; Ju, M. J.; Oh, Y. C.; Kim, D. S.

    2009-01-01

    The technology of ISO Solenoid Valves is now considered as a core technology in the fields of the production line of semi-conductor chips and the ISO fluid chips for medical applications. And ISO Solenoid Valves, which operate by compressed air, are characterized by high speed response, great repeatability and that the pressure on the cross sectional area of poppet is kept constant regardless of the fluctuation of the pressure exerted on the ports. The primary objective of this study is to compare the optimally designed Solenoid Valve with the actually produced one and to design a power saving circuit which can highly improve the efficiency by providing optimal current according to mechanical load.

  2. PENGENDALIAN KUALITAS PT AHM DENGAN MENGGUNAKAN ISO/TS 16949: 2002 UNTUK MENCEGAH KOMPONEN VALVE INLET BENGKOK PADA MOTOR SUPRA KHUSUSNYA MESIN NF100 (Studi Kasus Valve Inlet Bengkok di PT Astra Honda Motor

    Directory of Open Access Journals (Sweden)

    Naniek Utami Handayani

    2012-02-01

    Full Text Available Untuk memenuhi keinginan konsumen dalam hal mutu dan jumlah, PT AHM telah menerapkan ISO 9001:2000 (International Standard Organization versi tahun 2000, SIX SIGMA dan ISO/TS 16949:2002 untuk menangani customer claim dan memperbaiki mutu supplier yang ada. Sebelum penerapan ISO/TS 16949:2002, untuk keharmonisan kualitas supplier/penyalur tersebut, PT AHM telah menggunakan QS-9000 dalam mengendalikan kualitas produknya. Berhubung QS-9000 tidak diperbaharui lagi dan hanya akan berlaku sampai tahun 2006, maka sebagai gantinya perusahaan mengambil kebijakan untuk menerapkan ISO/TS 16949:2002 dan menyertakan dalam keseluruhannya kebutuhan ISO 9001:2000. Dari beberapa jenis motor yang diproduksi pada pabrik II dari PT AHM, jenis motor yang diproduksi adalah Legenda, Tiger, GL Max, Mega Pro dan Supra. Diantara kelima motor tersebut, Supra mempunyai prosentase permintaan yang paling tinggi dan juga sekaligus market claim tertingggi (periode Agustus s/d Desember 2004, yaitu sebesar 2,7%, sedangkan berdasarkan penelitian terhadap banyaknya claim customer terhadap komponen motor Supra periode Agustus s/d Desember 2004, claim terhadap komponen  terbesar mencapai 337 claim dari total 1440 claim. Komponen  motor Supra yang dimaksud disini adalah Valve Inlet. Dalam penelitian ini, dievaluasi hasil dari pelaksanaan persiapan penerapan ISO/TS 16949:2002 sebagai teknik pengendalian kualitas terbaru yang telah dipilih dengan menggunakan tools dari ISO/TS 16949:2002 yaitu SPC, FMEA dan Corrective Action. Hasil penelitian ini menunjukkan bahwa penyebab Valve Inlet bengkok bukan hanya berasal dari Valve inlet itu sendiri, melainkan juga sebagai akibat dari adanya ketidaksesuaian pada Guide Valve Inlet dan Cylinder head. Dari penelitian penerapan ISO/TS 16949:2002 di PT AHM dapat diketahui beberapa manfaat ISO/TS 16949:2002 dalam mengendalikan kualitas produk dan memenuhi kebutuhan customer. Kata Kunci: Market Claim, Customer Claim, ISO/TS 16949:2002, SPC, FMEA dan

  3. Multifunctional four-port directional control valve constructed from logic valves

    International Nuclear Information System (INIS)

    Lisowski, E.; Czyżycki, W.; Rajda, J.

    2014-01-01

    Highlights: • Directional valve with standard ISO 440-08 has been constructed from logic valves. • Only one innovative valve may replace whole family of the standard valves. • CFD analysis and bench tests of the innovative valve has been carried. • Parameters of the innovative valve are equaling or surpassing the standard ones. • The innovative valve has additional possibilities of pressure and flow control. - Abstract: The paper refers to four-port solenoid pilot operated valves, which are subplate mounted in a hydraulic system in accordance with the ISO 4401 standard. Their widespread use in many machines and devices causes a continuing interest in the development of their design by both the scientific centers and the industry. This paper presents an innovative directional control valve based on the use of logic valves and a methodology followed for the design of it by using Solid Edge CAD and ANSYS/Fluent CFD software. The valve design methodology takes into account the need to seek solutions that minimize flow resistance through the valve. For this purpose, the flow paths are prepared by means of CAD software and pressure-flow curves are determined as a result of CFD analysis. The obtained curves are compared with the curves available in the catalogs of spool type directional control valves. The new solution allows to replace the whole family of spool type four-port directional control valves by one valve built of logic valves. In addition, the innovative directional control valve provides leak-proof shutting the flow paths off and also it can control flow rate and even pressure of working liquid. A prototype of the valve designed by the presented method has been made and tested on the test bench. The results quoted in the paper confirm that the developed logic type directional control valve is able to meet all designed connection configurations, and the obtained pressure-flow curves show very good conformity with the results of CFD analysis

  4. A practical synthesis of long-chain iso-fatty acids (iso-C12–C19 and related natural products

    Directory of Open Access Journals (Sweden)

    Mark B. Richardson

    2013-09-01

    Full Text Available A gram-scale synthesis of terminally-branched iso-fatty acids (iso-C12–C19 was developed commencing with methyl undec-10-enoate (methyl undecylenate (for iso-C12–C14 or the C15 and C16 lactones pentadecanolide (for iso-C15–C17 and hexadecanolide (for iso-C18–C19. Central to the approaches outlined is the two-step construction of the terminal isopropyl group through addition of methylmagnesium bromide to the ester/lactones and selective reduction of the resulting tertiary alcohols. Thus, the C12, C17 and C18 iso-fatty acids were obtained in three steps from commercially-available starting materials, and the remaining C13–C16 and C19 iso-fatty acids were prepared by homologation or recursive dehomologations of these fatty acids or through intercepting appropriate intermediates. Highlighting the synthetic potential of the iso-fatty acids and various intermediates prepared herein, we describe the synthesis of the natural products (S-2,15-dimethylpalmitic acid, (S-2-hydroxy-15-methylpalmitic acid, and 2-oxo-14-methylpentadecane.

  5. Improved zeolite regeneration processes for preparing saturated branched-chain fatty acids

    Science.gov (United States)

    Ferrierite zeolite solid is an excellent catalyst for the skeletal isomerization of unsaturated linear-chain fatty acids (i.e., oleic acid) to unsaturated branched-chain fatty acids (i.e., iso-oleic acid) follow by hydrogenation to give saturated branched-chain fatty acids (i.e., isostearic acid). ...

  6. Branched-chain fatty acid biosynthesis in a branched-chain amino acid aminotransferase mutant of Staphylococcus carnosus

    DEFF Research Database (Denmark)

    Beck, Hans Christian

    2005-01-01

    Fatty acid biosynthesis by a mutant strain of Staphylococcus carnosus deficient in branched-chain amino acid aminotransferase (IlvE) activity was analysed. This mutant was unable to produce the appropriate branched-chain alpha-ketoacid precursors for branched-chain fatty acid biosynthesis from...... in rich medium and growth in defined medium supplemented with 2-methylpropanoic acid lead to extensive alteration of the fatty acid composition in the cell membrane. In rich medium, a change from 51.7% to 17.1% anteiso-C15:0, and from 3.6% to 33.9% iso-C14:0 fatty acids as compared to the wild-type strain...... for 2-methylpropanoic acid production, revealing that the IlvE protein plays an important, but not essential role in the biosynthesis of branched-chain fatty acids and secondary metabolites in S. carnosus....

  7. Hemodynamics in the Valsalva sinuses after transcatheter aortic valve implantation (TAVI).

    Science.gov (United States)

    Ducci, Andrea; Tzamtzis, Spyridon; Mullen, Michael J; Burriesci, Gaetano

    2013-09-01

    The study aim was to assess, in vitro, the hemodynamic modifications produced by transcatheter valves in the Valsalva sinuses, by mean of phase-resolved particle image velocimetry (PIV) measurements. Flow measurements were performed on a glass mock aortic root that included three polymeric valve leaflets, before and after the implantation of a Medtronic CoreValve device and of an Edwards SAPIEN valve. All experiments were carried out in a hydro-mechanical cardiovascular pulse duplicator system (Vivitro Superpump System SP3891) that reproduced physiologically equivalent pressures and flow rates conforming to the requirements of the standard ISO 5840:2005. The flow dynamics, before and after implantation of the two prosthetic devices, was characterized on the basis of phase-resolved velocity field and viscous shear rate measurements. Direct comparison indicated that both transcatheter valves determined a significant variation of flow during the early stages of valve opening and during valve closure. In general, the presence of the two valve implants significantly reduced the flow activity in the Valsalva sinuses, promoting regions of stagnation at their base. The reduction in flow in the Valsalva sinuses could be associated with the higher incidence of ischemic events reported after transcatheter heart valve implantation.

  8. Radial Force: An Underestimated Parameter in Oversizing Transcatheter Aortic Valve Replacement Prostheses: In Vitro Analysis with Five Commercialized Valves.

    Science.gov (United States)

    Egron, Sandrine; Fujita, Buntaro; Gullón, Lucía; Désirée, Pott; Schmitz-Rode, Thomas; Ensminger, Stephan; Steinseifer, Ulrich

    2017-09-05

    The goal is to inform in depth on transcatheter aortic valve replacement (TAVR) prosthesis mechanical behavior, depending on frame type, design, and size, and how it crucially impacts the oversizing issue in clinical use, and ultimately the procedure outcome. Transcatheter aortic valve replacement is an established therapy for high-risk patients suffering from aortic stenosis, and the indication for TAVR is progressively expanding to intermediate-risk patients. Choosing the optimal oversizing degree is crucial to safely anchor the TAVR valve-which involves limiting the risks for embolism, aortic regurgitation, conductance disturbance, or annulus rupture-and to increase the valve prosthesis performance. The radial force (RF) profiles of five TAVR prostheses were measured in vitro: the CoreValve 23 and 26 (Medtronic, MN), the Acurate neo S (Symetis, Switzerland), and the SAPIEN XT 23 and 26 (Edwards Lifesciences, CA). Measurements were run with the RX Machine equipment (Machine Solutions Inc., AZ), which is used in ISO standard tests for intravascular stents. Test protocols were adapted for TAVR prostheses. With the prostheses RF profiles' results, mechanical behavior differences could be described and discussed in terms of oversizing strategy and clinical impact for all five valves. Besides, crossing the prostheses' RF profiles with their recommended size windows made the assessment of borderline size cases possible and helped analyze the risks when accurate measurement of patient aortic annulus proves difficult. The prostheses' RF profiles bring new support in clinical decision-making for valve type and size in patients.

  9. Valve packing manual. A maintenance application guide

    International Nuclear Information System (INIS)

    Aikin, J.A.; McCutcheon, R.G.; Cumming, D.

    1997-01-01

    Since 1970, AECL Chalk River Mechanical Equipment Development (MED) branch has invested over 175 person years in testing related to improving valve packing performance. Successful developments, including, 'live-loading', reduced packing heights, and performance-based packing qualification testing have been implemented. Since 1986, MED and the Integrated Valve Actuator Program Task Force - Valve Packing Steering Committee (IVAP-VPSC) have been involved in the development of combination die-formed graphite packing for use in CANDU plants. Many reports, articles, and specifications have been issued. Due to the large amount of test data and reports, a more user-friendly document has been prepared for everyday use. The Valve Packing Manual is based on many years of MED research and testing, as well as operating experience from CANDU nuclear generating stations (NGS). Since 1986, packing research and testing has been funded by the CANDU Owners Group (COG), the Electric Power Research Institute (EPRI), and participating valve packing manufacturers. The Valve Packing Manual (VPM) provides topical summaries of all work related to valve packing done since 1985. It includes advances in configuration design, stem packing friction, materials specifications, and installation procedures. This paper provides an overview on the application of the VPM with a focus on qualification testing, packing configuration, and stem packing friction. (author)

  10. Structure and Biosynthesis of Branched Wax Compounds on Wild Type and Wax Biosynthesis Mutants of Arabidopsis thaliana.

    Science.gov (United States)

    Busta, Lucas; Jetter, Reinhard

    2017-06-01

    The cuticle is a waxy composite that protects the aerial organs of land plans from non-stomatal water loss. The chemical make-up of the cuticular wax mixture plays a central role in defining the water barrier, but structure-function relationships have not been established so far, in part due to gaps in our understanding of wax structures and biosynthesis. While wax compounds with saturated, linear hydrocarbon tails have been investigated in detail, very little is known about compounds with modified aliphatic tails, which comprise substantial portions of some plant wax mixtures. This study aimed to investigate the structures, abundances and biosynthesis of branched compounds on the species for which wax biosynthesis is best understood: Arabidopsis thaliana. Microscale derivatization, mass spectral interpretation and organic synthesis identified homologous series of iso-alkanes and iso-alcohols on flowers and leaves, respectively. These comprised approximately 10-15% of wild type wax mixtures. The abundances of both branched wax constituents and accompanying unbranched compounds were reduced on the cer6, cer3 and cer1 mutants but not cer4, indicating that branched compounds are in part synthesized by the same machinery as unbranched compounds. In contrast, the abundances of unbranched, but not branched, wax constituents were reduced on the cer2 and cer26 mutants, suggesting that the pathways to both types of compounds deviate in later steps of chain elongation. Finally, the abundances of branched, but not unbranched, wax compounds were reduced on the cer16 mutant, and the (uncharacterized) CER16 protein may therefore be controlling the relative abundances of iso-alkanes and iso-alcohols on Arabidopsis surfaces. © The Author 2017. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  11. Pressure-dependent kinetics of initial reactions in iso-octane pyrolysis.

    Science.gov (United States)

    Ning, HongBo; Gong, ChunMing; Li, ZeRong; Li, XiangYuan

    2015-05-07

    This study focuses on the studies of the main pressure-dependent reaction types of iso-octane (iso-C8H18) pyrolysis, including initial C-C bond fission of iso-octane, isomerization, and β-scission reactions of the alkyl radicals produced by the C-C bond fission of iso-octane. For the C-C bond fission of iso-octane, the minimum energy potentials are calculated at the CASPT2(2e,2o)/6-31+G(d,p)//CAS(2e,2o)/6-31+G(d,p) level of theory. For the isomerization and the β-scission reactions of the alkyl radicals, the optimization of the geometries and the vibrational frequencies of the reactants, transition states, and products are performed at the B3LYP/CBSB7 level, and their single point energies are calculated by using the composite CBS-QB3 method. Variable reaction coordinate transition state theory (VRC-TST) is used for the high-pressure limit rate constant calculation and Rice-Ramsperger-Kassel-Marcus/master equation (RRKM/ME) is used to calculate the pressure-dependent rate constants of these channels with pressure varying from 0.01-100 atm. The rate constants obtained in this work are in good agreement with those available from literatures. We have updated the rate constants and thermodynamic parameters for species involved in these reactions into a current chemical kinetic mechanism and also have improved the concentration profiles of main products such as C3H6 and C4H6 in the shock tube pyrolysis of iso-octane. The results of this study provide insight into the pyrolysis of iso-octane and will be helpful in the future development of branched paraffin kinetic mechanisms.

  12. ISO Science Legacy A Compact Review of ISO Major Achievements

    CERN Document Server

    Cesarsky, Catherine J

    2006-01-01

    Stars are born and die in clouds of gas and dust, opaque to most types of radiation, but transparent in the infrared. Requiring complex detectors, space missions and cooled telescopes, infrared astronomy is the last branch of this discipline to come of age. After a very successful sky survey performed in the eighties by the IRAS satellite, the Infrared Space Observatory, in the nineties, brought spectacular advances in the understanding of the processes giving rise to powerful infrared emission by a great variety of celestial sources. Outstanding results have been obtained on the bright comet Hale-Bopp, and in particular of its water spectrum, as well as on the formation, chemistry and dynamics of planetary objects in the solar system. Ideas on the early stages of stellar formation and on the stellar initial mass function have been clarified. ISO is the first facility in space able to provide a systematic diagnosis of the physical phenomena and the chemistry in the close environment of pre-main sequence stars...

  13. Technical evaluation: 300 Area steam line valve accident

    International Nuclear Information System (INIS)

    1993-08-01

    On June 7, 1993, a journeyman power operator (JPO) was severely burned and later died as a result of the failure of a 6-in. valve that occurred when he attempted to open main steam supply (MSS) valve MSS-25 in the U-3 valve pit. The pit is located northwest of Building 331 in the 300 Area of the Hanford Site. Figure 1-1 shows a layout of the 300 Area steam piping system including the U-3 steam valve pit. Figure 1-2 shows a cutaway view of the approximately 10- by 13- by 16-ft-high valve pit with its various steam valves and connecting piping. Valve MSS-25, an 8-in. valve, is located at the bottom of the pit. The failed 6-in. valve was located at the top of the pit where it branched from the upper portion of the 8-in. line at the 8- by 8- by 6-in. tee and was then ''blanked off'' with a blind flange. The purpose of this technical evaluation was to determine the cause of the accident that led to the failure of the 6-in. valve. The probable cause for the 6-in. valve failure was determined by visual, nondestructive, and destructive examination of the failed valve and by metallurgical analysis of the fractured region of the valve. The cause of the accident was ultimately identified by correlating the observed failure mode to the most probable physical phenomenon. Thermal-hydraulic analyses, component stress analyses, and tests were performed to verify that the probable physical phenomenon could be reasonably expected to produce the failure in the valve that was observed

  14. Components for containment enclosures. Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 11933 consists of the following parts, under the general title Components for containment enclosures: Part 1: Glove/bag ports, bungs for glove/bag ports, enclosure rings and interchangeable units; Part 2: Gloves, welded bags, gaiters for remote-handling tongs and for manipulators; Part 3: Transfer systems such as plain doors, airlock chambers, double door transfer systems, leaktight connections for waste drums; Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices; Part 5: Penetrations for electrical and fluid circuits. This part of ISO 11933 specifies the design criteria and the characteristics of various components used for ventilation and gas-cleaning in containment enclosures. These components are either directly fixed to the containment enclosure wall, or used in the environment of a shielded or unshielded containment enclosure or line of such enclosures. They can be used alone or in conjunction with other mechanical components, including those specified in ISO 11933-1 and ISO 11933-3. This part of ISO 11933 is applicable to: filtering devices, including high-efficiency particulate air (HEPA) filters and iodine traps; safety valves and pressure regulators; systems ensuring the mechanical protection of containment enclosures; control and pressure-measurement devices

  15. Magnetostrictive GMR spin valves with composite FeGa/FeCo free layers

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Luping [Key Laboratory of Magnetic Materials and Devices & Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Institute of Materials Science, School of Materials Science and Engineering, Shanghai University, Shanghai 200072 (China); Zhan, Qingfeng, E-mail: zhanqf@nimte.ac.cn, E-mail: runweili@nimte.ac.cn; Yang, Huali; Li, Huihui; Zhang, Shuanglan; Liu, Yiwei; Wang, Baomin; Li, Run-Wei, E-mail: zhanqf@nimte.ac.cn, E-mail: runweili@nimte.ac.cn [Key Laboratory of Magnetic Materials and Devices & Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Tan, Xiaohua [Institute of Materials Science, School of Materials Science and Engineering, Shanghai University, Shanghai 200072 (China)

    2016-03-15

    We have fabricated strain-sensitive spin valves on flexible substrates by utilizing the large magnetostrictive FeGa alloy to promote the strain sensitivity and the composite free layer of FeGa/FeCo to avoid the drastic reduction of giant magnetoresistance (GMR) ratio. This kind of spin valve (SV-FeGa/FeCo) displays a MR ratio about 5.9%, which is comparable to that of the conventional spin valve (SV-FeCo) with a single FeCo free layer. Different from the previously reported works on magnetostrictive spin valves, the SV-FeGa/FeCo displays an asymmetric strain dependent GMR behavior. Upon increasing the lateral strain, the MR ratio for the ascending branch decreases more quickly than that for the descending branch, which is ascribed to the formation of a spiraling spin structure around the FeGa/FeCo interface under the combined influences of both magnetic field and mechanical strain. A strain sensitivity of GF = 7.2 was achieved at a magnetic bias field of -30 Oe in flexible SV-FeGa/FeCo, which is significantly larger than that of SV-FeCo.

  16. Magnetostrictive GMR spin valves with composite FeGa/FeCo free layers

    International Nuclear Information System (INIS)

    Liu, Luping; Zhan, Qingfeng; Yang, Huali; Li, Huihui; Zhang, Shuanglan; Liu, Yiwei; Wang, Baomin; Li, Run-Wei; Tan, Xiaohua

    2016-01-01

    We have fabricated strain-sensitive spin valves on flexible substrates by utilizing the large magnetostrictive FeGa alloy to promote the strain sensitivity and the composite free layer of FeGa/FeCo to avoid the drastic reduction of giant magnetoresistance (GMR) ratio. This kind of spin valve (SV-FeGa/FeCo) displays a MR ratio about 5.9%, which is comparable to that of the conventional spin valve (SV-FeCo) with a single FeCo free layer. Different from the previously reported works on magnetostrictive spin valves, the SV-FeGa/FeCo displays an asymmetric strain dependent GMR behavior. Upon increasing the lateral strain, the MR ratio for the ascending branch decreases more quickly than that for the descending branch, which is ascribed to the formation of a spiraling spin structure around the FeGa/FeCo interface under the combined influences of both magnetic field and mechanical strain. A strain sensitivity of GF = 7.2 was achieved at a magnetic bias field of -30 Oe in flexible SV-FeGa/FeCo, which is significantly larger than that of SV-FeCo.

  17. Magnetostrictive GMR spin valves with composite FeGa/FeCo free layers

    Science.gov (United States)

    Liu, Luping; Zhan, Qingfeng; Yang, Huali; Li, Huihui; Zhang, Shuanglan; Liu, Yiwei; Wang, Baomin; Tan, Xiaohua; Li, Run-Wei

    2016-03-01

    We have fabricated strain-sensitive spin valves on flexible substrates by utilizing the large magnetostrictive FeGa alloy to promote the strain sensitivity and the composite free layer of FeGa/FeCo to avoid the drastic reduction of giant magnetoresistance (GMR) ratio. This kind of spin valve (SV-FeGa/FeCo) displays a MR ratio about 5.9%, which is comparable to that of the conventional spin valve (SV-FeCo) with a single FeCo free layer. Different from the previously reported works on magnetostrictive spin valves, the SV-FeGa/FeCo displays an asymmetric strain dependent GMR behavior. Upon increasing the lateral strain, the MR ratio for the ascending branch decreases more quickly than that for the descending branch, which is ascribed to the formation of a spiraling spin structure around the FeGa/FeCo interface under the combined influences of both magnetic field and mechanical strain. A strain sensitivity of GF = 7.2 was achieved at a magnetic bias field of -30 Oe in flexible SV-FeGa/FeCo, which is significantly larger than that of SV-FeCo.

  18. The Performance Test for Reactor Coolant Pump (RCP) adopting Variable Restriction Orifice Type Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.; Bae, B. U.; Cho, Y. J. and others

    2014-05-15

    The design values of the RCPTF are 17.2 MPa, 343 .deg. C, 11.7 m{sup 3}/s, and 13 MW in the maximum pressure, temperature, flow rate, and electrical power, respectively. In the RCPTF, various types of tests can be performed including a hydraulic performance test to acquire a H-Q curve as well seal transient tests, thrust bearing transient test, cost down test, NPSHR verification test, and so on. After a commissioning startup test was successfully perfomed, mechanical structures are improved including a flow stabilizer and variable restriction orifice. Two- branch pipe (Y-branch) was installed to regulate the flow rate in the range of performance tests. In the main pipe, a flow restrictor (RO: Restriction Orifice) for limiting the maximum flow rate was installed. In the branch pipe line, a globe valve and a butterfly valves for regulating the flow rate was located on the each branch line. When the pressure loss of the valve side is smaller than that of the RO side, the flow rate of valve side was increasing and the flow disturbance was occurred in the lower pipe line. Due to flow disturbnace, it is to cause an error when measuring RCP head and flow measurement of the venturi flow meter installed in the lower main pipe line, and thus leading to a decrease in measurement accuracy as a result. To increase the efficiency of the flow control availability of the test facility, the variable restriction orifice (VRO) type flow control valve was designed and manufactured. In the RCPTF in KAERI, the performance tests and various kinds of transient tests of the RCP were successfully performed. In this study, H-Q curve of the pump using the VRO revealed a similar trend to the result from two ROs. The VRO was confirmed to effectively cover the full test range of the flow rate.

  19. Adsorption and separation of n/iso-pentane on zeolites: A GCMC study.

    Science.gov (United States)

    Fu, Hui; Qin, Hansong; Wang, Yajun; Liu, Yibin; Yang, Chaohe; Shan, Honghong

    2018-03-01

    Separation of branched chain hydrocarbons and straight chain hydrocarbons is very important in the isomerization process. Grand canonical ensemble Monte Carlo simulations were used to investigate the adsorption and separation of iso-pentane and n-pentane in four types of zeolites: MWW, BOG, MFI, and LTA. The computation of the pure components indicates that the adsorption capacity is affected by physical properties of zeolite, like pore size and structures, and isosteric heat. In BOG, MFI and LTA, the amount of adsorption of n-pentane is higher than iso-pentane, while the phenomenon is contrary in MWW. For a given zeolite, a stronger adsorption heat corresponds to a higher loading. In the binary mixture simulations, the separation capacity of n-and iso-pentane increases with the elevated pressure and the increasing iso-pentane composition. The adsorption mechanism and competition process have been examined. Preferential adsorption contributions prevail at low pressure, however, the size effect becomes important with the increasing pressure, and the relatively smaller n-pentane gradually competes successfully in binary adsorption. Among these zeolites, MFI has the best separation performance due to its high shape selectivity. This work helps to better understand the adsorption and separation performance of n- and iso-pentane in different zeolites and explain the relationship between zeolite structures and adsorption performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. The international ISOE programme. ISOE European technical centre activities

    International Nuclear Information System (INIS)

    Ascenzo, L. d'; Crouail, P.; Levy, F.; Livolsi, P.; Schieber, C.; Lefaure, C.

    1996-01-01

    The CEPN has been involved from the beginning in the NEA Information System on Occupational Exposure (ISOE). As ISOE European Technical Centre, the CEPN is responsible for the collection and distribution of European data to the various ISOE partners, the collection of data from the other regional technical centres, and the custodianship of the full ISOE data base. This full data base is updated annually and distributed to all the European participating utilities and to other Regional Technical Centres. The European data are also sent to the European Commission (EC) as a contribution to their own occupational exposure data base. In addition to these activities, the CEPN has developed two computer programmes under Windows to facilitate the management of ISOE data bases. The first software, called ASPIC, allows participating utilities to electronically complete NEA1 and NEA3 questionnaires, as well as to consult the NEA3 data base using key words search routine. This software is available in six different languages. The second programme is a relational data base for the performance of statistical analyses using data from NEA1. The CEPN also contributes significantly to the efficient flow of information through the ISOE Network. This includes participation in the preparation and distribution of the ISOE Annual Report (which presents and analyses NEAI data), ISOE Information Sheets (providing short synthesis using NEA1 and NEA3 data), and Technical Reports. Participating Authorities and Utilities have each made information requests to the CEPN concerning dosimetric data, radiation protection experiences, policies and practices. Some examples of these requests, and of the types of data provided, will be presented. (author)

  1. Integrated management system: The integration of ISO 9001, ISO 14001, OHSAS 18001 and ISO 31000

    Science.gov (United States)

    Muzaimi, Hafizzudin; Chew, Boon Cheong; Hamid, Syaiful Rizal

    2017-03-01

    The implementation of integrated management system (IMS) for better quality management has become a preference for many organizations. This can be seen as many organizations used the combination of quality ISO 9001, an environment ISO 14001 and occupational health and safety management system OHSAS 18001 as a core for the IMS that largely implemented. Besides, the linked between quality management with risk management system need to be identified as the management system that enhance the effectiveness of IMS. Therefore, the risk management system ISO 31000 also presented as a part of integration. In nowadays competitive environment, the increasing pressure and needs from customer or stakeholders make it compulsory for the organization to propose the new system and standards. This paper presents and discusses about the benefit of integration, the management system components that can be converged and the implementation approach. A series of interview was conducted through in-depth interviews with 8 experts in this field, while data collected were analyzed qualitatively. The results consist of 16 factors of IMS implementation that have been identified and the use of PDCA approach for an effective implementation of IMS. As a conclusion, the paper proposes the integration of four management systems (ISO 9001, ISO 14001, OHSAS 18001 and ISO 31000) and on how the IMS can be used to structure the process of management for quality management towards sustainability practices in the organization.

  2. Electric actuator for the sempell gate valve

    Energy Technology Data Exchange (ETDEWEB)

    Herbstritt, E.C.

    1996-12-01

    The automation of valves has a primary importance in the scope of central control and regulation of power generation processes in power plants and especially in nuclear power plants. AUMA WERNER RIESTER GmbH & Co. KG is considered a leading manufacturer of electric actuators for the automation of valves. More than 30 years experience in designing, developing, and manufacturing provide a sound basis for offering reliable products, especially for nuclear applications. The quality assurance system of AUMA was developed according to 10 CFR 50, Appendix B and has been consistently accomplished. The program was certified by the TUV Germany (Technical Authorized Inspection Agency), according to ISO-9001, in 1994. AUMA offers two actuator type ranges for application in nuclear power plants. The range SAI is qualified according to IEEE 382-1978 and is designed for inside containment. The range SAN is qualified according to IEEE 382-1985 and KTA 3504-1988 for use in non-radioactive applications in the nuclear power plants.

  3. Structure–property relationships in ionic liquids: Influence of branched and cyclic groups on vaporization enthalpies of imidazolium-based ILs

    International Nuclear Information System (INIS)

    Zaitsau, Dzmitry H.; Varfolomeev, Mikhail A.; Verevkin, Sergey P.; Stanton, Alexander D.; Hindman, Michelle S.; Bara, Jason E.

    2016-01-01

    Highlights: • Ionic liquids [Rmim][NTf_2] with iso-alkyl and cyclic substituents were synthesized. • Vaporization enthalpies were measured using quartz-crystal microbalance. • Data consistency was tested by comparison with the homomorph compounds. • Vaporization enthalpies of branched ILs are generally on the same level as for linear. • These findings are useful for the quick estimation of vaporization enthalpies. - Abstract: Ionic liquids (ILs) with branched and cyclic substituents are seldom studied in the literature, and as such there are little to no data characterizing their thermophysical properties. ILs with branched and cyclic substituents are just as convenient to synthesize and study as their counterparts with linear substituents, but the effects of these substituents on IL properties are not yet well-defined due to the preference for linear substituents. Standard molar vaporization enthalpies of six imidazolium based ionic liquids [Rmim][NTf_2] with iso-alkyl and cyclic substituents (R = iso-propyl, iso-butyl, sec-butyl, methylcyclopropyl, cyclopentyl and methylcyclohexyl) were derived from quartz-crystal microbalance (QCM) method. Enthalpies of vaporization measured at elevated temperatures have been adjusted to the reference temperature 298 K and tested for consistency by comparison with the homomorphy alkane, alkylbenzenes and alkyl-imidazoles. It was found that vaporization enthalpies of ILs with the iso-alkyl and cyclic groups are generally on the same level within (±2 to 3) kJ · mol"−"1 significantly compared to the analogous ILs with the imidazolium cation substituted with the linear alkyl substituents of the same chain length. These findings are useful for the quick estimation of vaporization enthalpies of various substituted IL cations (e.g. pyrrolidinium, ammonium, pyridinium, etc.).

  4. A visualization study of flow-induced acoustic resonance in a branched pipe

    International Nuclear Information System (INIS)

    Li, Yanrong; Someya, Satoshi; Okamoto, Koji

    2008-01-01

    Systems with closed side-branches are liable to an excitation of sound, as called cavity tones. It may occur in pipe branches leading to safety valves or to boiler relief valves. The outbreak mechanism of the cavity tone has been known by phase-averaged measurement in previous researches, while the relation between sound propagation and flow field is still unclear due to the difficulty of detecting instantaneous pressure field. High time-resolved PIV has a possibility to analyze the pressure field and the relation mentioned above. In this report, flow-induced acoustic resonances of piping system containing closed side-branches were investigated experimentally. A High-Time-Resolved PIV technique was applied to measure a gas-flow in a cavity-tone. Air flow containing an oil mist as tracer particles was measured using a high frequency pulse laser and a high-speed camera. The present investigation on the coaxial closed side-branches is the first rudimentary study to measure the flow field two-dimensionally and simultaneously with the pressure measurement at multi-points and to visualize the fluid flow in the cross-section by using PIV. The fluid flows at different points in the cavity interact with some phase differences and the relation should be clarified. (author)

  5. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. ISO27001 / ISO27002 a pocket guide

    CERN Document Server

    Calder, Alan

    2013-01-01

    Information is one of your organisation's most important resources. Keeping it secure is therefore vital to your business. This handy pocket guide is an essential overview of two key information security standards that cover the formal requirements (ISO27001:2013) for creating an Information Security Management System (ISMS), and the best-practice recommendations (ISO27002:2013) for those responsible for initiating, implementing or maintaining it.

  7. Physical properties and fiber dimension in Stem, Branch and root of Alder Wood

    OpenAIRE

    Moya-Roque, Roger; Kiaei, Majid

    2015-01-01

    The aim of this study was to determine physical properties and fiber dimensions in stem, branch and root wood for alder (Alnus glutinosa L) species. For this purpose, three normal alder trees were selected from Khanican forest in north of Iran. Disks were taken from three parts such as stem, branch and root of trees. Testing samples were randomly taken at disk surfaces to examine the physical properties (according to the ISO standard for oven-dry density and volumetric shrinkage) and fiber di...

  8. Pressure locking and thermal binding of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, E.M.

    1996-12-01

    Pressure locking and thermal binding represent potential common mode failure mechanisms that can cause safety-related power-operated gate valves to fail in the closed position, thus rendering redundant safety-related systems incapable of performing their safety functions. Supplement 6 to Generic Letter 89-10, {open_quotes}Safety-Related Motor-Operated Gate Valve Testing and Surveillance,{close_quotes} provided an acceptable approach to addressing pressure locking and thermal binding of gate valves. More recently, the NRC has issued Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves,{close_quotes} to request that licensees take certain actions to ensure that safety-related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing their safety functions within the current licensing bases. Over the past two years, several plants in Region I determined that valves in certain systems were potentially susceptible to pressure locking and thermal binding, and have taken various corrective actions. The NRC Region I Systems Engineering Branch has been actively involved in the inspection of licensee actions in response to the pressure locking and thermal binding issue. Region I continues to maintain an active involvement in this area, including participation with the Office of Nuclear Reactor Regulation in reviewing licensee responses to Generic Letter 95-07.

  9. IsoBank workshop held at IsoEcol10 - University of Tokyo 2016

    OpenAIRE

    Hayden, Brian

    2016-01-01

    IsoBank is a repository for stable isotope values and relevant metadata. These slides were presented at a workshop held during IsoEcol10 to refine and design the IsoBank for the needs of a diverse group of researchers.

  10. ISO radiation protection standards

    International Nuclear Information System (INIS)

    Becker, K.; West, N.

    1981-01-01

    After a brief description of the International Organization for Standardization (ISO) and its Technical Committee (TC) 85 ''Nuclear Energy'', the work of its Sub-Committee (SC) 2 ''Radiation Protection'' is described in some detail. Several international standards on subjects closely related to radiation protection have already been published, for example ISO-361 (Basic radiation protection symbol), ISO-1757 (Photographic dosimeters), ISO-1758 and 1759 (Direct and indirect-reading pocket exposure meters), ISO-2889 (Sampling of airborne radioactive materials), ISO-4037 (X and gamma reference radiations for calibration) and ISO-4071 (Testing of exposure meters and dosimeters). TC 85/SC 2 has currently eight active Working Groups (WG) dealing with 14 standards projects, mostly in advanced stages, in such fields as neutron and beta reference radiations, and X and gamma radiations of high and low dose-rates and high energies for calibration purposes, reference radiations for surface contamination apparatus, ejection systems for gamma radiography apparatus, industrial and laboratory irradiators, lead shielding units, protective clothing, thermoluminescence dosemeters, radioelement gauges, and surface contamination and decontamination. (author)

  11. 78 FR 38728 - Notice of Issuance of Final Determination Concerning Valves

    Science.gov (United States)

    2013-06-27

    ... of certain valves to be offered to the U.S. Government under an undesignated government procurement... CONTACT: Fernando Pe[ntilde]a, Esq., Valuation and Special Programs Branch, Office of International Trade... undesignated government procurement contract. The final determination, Headquarters Ruling Letter H233698, was...

  12. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  13. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  14. A comprehensive iso-octane combustion model with improved thermochemistry and chemical kinetics

    KAUST Repository

    Atef, Nour

    2017-02-05

    Iso-Octane (2,2,4-trimethylpentane) is a primary reference fuel and an important component of gasoline fuels. Moreover, it is a key component used in surrogates to study the ignition and burning characteristics of gasoline fuels. This paper presents an updated chemical kinetic model for iso-octane combustion. Specifically, the thermodynamic data and reaction kinetics of iso-octane have been re-assessed based on new thermodynamic group values and recently evaluated rate coefficients from the literature. The adopted rate coefficients were either experimentally measured or determined by analogy to theoretically calculated values. Furthermore, new alternative isomerization pathways for peroxy-alkyl hydroperoxide (ȮOQOOH) radicals were added to the reaction mechanism. The updated kinetic model was compared against new ignition delay data measured in rapid compression machines (RCM) and a high-pressure shock tube. These experiments were conducted at pressures of 20 and 40 atm, at equivalence ratios of 0.4 and 1.0, and at temperatures in the range of 632–1060 K. The updated model was further compared against shock tube ignition delay times, jet-stirred reactor oxidation speciation data, premixed laminar flame speeds, counterflow diffusion flame ignition, and shock tube pyrolysis speciation data available in the literature. Finally, the updated model was used to investigate the importance of alternative isomerization pathways in the low temperature oxidation of highly branched alkanes. When compared to available models in the literature, the present model represents the current state-of-the-art in fundamental thermochemistry and reaction kinetics of iso-octane; and thus provides the best prediction of wide ranging experimental data and fundamental insights into iso-octane combustion chemistry.

  15. Accreditation - ISO/IEC 17025

    Science.gov (United States)

    Kaus, Rüdiger

    This chapter gives the background on the accreditation of testing and calibration laboratories according to ISO/IEC 17025 and sets out the requirements of this international standard. ISO 15189 describes similar requirements especially tailored for medical laboratories. Because of these similarities ISO 15189 is not separately mentioned throughout this lecture.

  16. Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System.

    Science.gov (United States)

    van der Boon, Robert M A; Van Mieghem, Nicolas M; Theuns, Dominic A; Nuis, Rutger-Jan; Nauta, Sjoerd T; Serruys, Patrick W; Jordaens, Luc; van Domburg, Ron T; de Jaegere, Peter P T

    2013-09-30

    To determine pacemaker (PM) dependency at follow-up visit in patients who underwent new permanent pacemaker implantation (PPI) following transcatheter aortic valve implantation (TAVI). Single center prospective observational study including 167 patients without previous PM implantation who underwent TAVI with the self-expanding Medtronic CoreValve System (MCS) between November 2005 and February 2011. PM dependency was defined by the presence of a high degree atrioventricular block (HDAVB; second [AV2] and third degree [AV3B]), or a slow (atrial fibrilation with slow response (n=1, 2.8%) and left bundle branch block (n=1, 2.8%). Long term follow-up was complete for all patients and ranged from 1 to 40 months (median (IQR): 11.5 (5.0-18.0 months). Of those patients with a HDAVB, 16 out of the 30 patients (53.3%) were PM independent at follow-up visit (complete or partial resolution of the AV conduction abnormality). Overall, 20 out of the 36 patients (55.6%) who received a new PM following TAVI were PM independent at follow-up. Partial and even complete resolution of peri-operative AV conduction abnormalities after MCS valve implantation occurred in more than half of the patients. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Structure of FabH and factors affecting the distribution of branched fatty acids in Micrococcus luteus.

    Science.gov (United States)

    Pereira, Jose H; Goh, Ee-Been; Keasling, Jay D; Beller, Harry R; Adams, Paul D

    2012-10-01

    Micrococcus luteus is a Gram-positive bacterium that produces iso- and anteiso-branched alkenes by the head-to-head condensation of fatty-acid thioesters [coenzyme A (CoA) or acyl carrier protein (ACP)]; this activity is of interest for the production of advanced biofuels. In an effort to better understand the control of the formation of branched fatty acids in M. luteus, the structure of FabH (MlFabH) was determined. FabH, or β-ketoacyl-ACP synthase III, catalyzes the initial step of fatty-acid biosynthesis: the condensation of malonyl-ACP with an acyl-CoA. Analysis of the MlFabH structure provides insights into its substrate selectivity with regard to length and branching of the acyl-CoA. The most structurally divergent region of FabH is the L9 loop region located at the dimer interface, which is involved in the formation of the acyl-binding channel and thus limits the substrate-channel size. The residue Phe336, which is positioned near the catalytic triad, appears to play a major role in branched-substrate selectivity. In addition to structural studies of MlFabH, transcriptional studies of M. luteus were also performed, focusing on the increase in the ratio of anteiso:iso-branched alkenes that was observed during the transition from early to late stationary phase. Gene-expression microarray analysis identified two genes involved in leucine and isoleucine metabolism that may explain this transition.

  18. Internal Audit Status For ISO 9001 And ISO/ IEC 17025 In Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Fazila Said; Nurul Huda Mudri; Nik Arlina Ali

    2012-01-01

    The development of MS ISO 9001 and MS ISO/ IEC 17025 in Malaysian Nuclear Agency is the basic step to enhance and improve the Quality Management System (QMS) for processes and laboratories that involve customers and suppliers in delivering products and services. The effectiveness of QMS is monitored by Research and Innovation Management Centre (RIMC) to ensure that all activities related to audit such as Internal Audit are well organized and implemented as documented in quality manual and procedure. This paper will discuss the status of internal audit for processes that implement MS ISO 9001 and laboratories that accredited with MS/ ISO IEC 17025 in year 2008, 2009 and 2010. The total of non-conformance (nc) and opportunity for improvement (ofi) for processes and laboratories and their numbers as per clause in MS ISO 9001 and MS ISO/ IEC 17025 are the indicators that reflects the effectiveness of QMS. Then, the total effectiveness of QMS for MS 9001 and MS ISO/ IEC 17025 is also determined via the number of conformance clause versus non-conformance clause for those three years. (author)

  19. Food service compliance with ISO 14001 and ISO 22000

    Directory of Open Access Journals (Sweden)

    Laura Lyra Santos

    2012-06-01

    Full Text Available OBJECTIVE: The objective of this study was to assess food service environmental and food safety management systems according to two checklists based on ABNT ISO 22000 and 14001. METHODS: This exploratory and descriptive study investigated a-la-carte food services of the Federal District, Brazil. Two checklists were developed to investigate ISO 14001 and 22000 compliance. A total of 37 food services were selected from the list of the Brazilian Association of Bars and Restaurants by simple random sampling. Checklist results were analyzed according to ANVISA resolution nº 275/2002. RESULTS: Only five food services employed dietitians to supervise meal production. These establishments achieved the highest ISO compliance. However, no establishment had more than 50% ISO 14001 or 22000 compliance. Restaurants showed little concern for the environment and disobeyed waste disposal laws by not separating recyclables from non-recyclables. CONCLUSION: The study food services do not have safe meal production systems, evidenced by non-conformity with the reference standards. Additionally, they do not attempt to reduce the environmental impact of their wastes. Food services supervised by dietitians are better prepared to produce safe foods.

  20. ISO 9000

    International Nuclear Information System (INIS)

    Graham, J.F.

    1992-01-01

    The European Community has adopted the Single European Act. The act states that in order to do business in Europe after 1992, a supplied is expected to be ISO 9000 registered. This paper reports on ISO 9000, which is a systematic approach to implementing a quality system. It is not in the category of technical or product standards, but a standard relating to management of quality in that sector of a company seeking registration. If a company is already systematically practicing quality improvement, these efforts will be applicable to the ISO 9000 certification process. A company will need to refine and update procedures and develop a quality manual. An internal auditing and a corrective action system will also have to be established. The latter addresses audit results, customer complaints, quality system problems, and internal quality improvement suggestions

  1. Structure of FabH and factors affecting the distribution of branched fatty acids in Micrococcus luteus

    International Nuclear Information System (INIS)

    Pereira, Jose H.; Goh, Ee-Been; Keasling, Jay D.; Beller, Harry R.; Adams, Paul D.

    2012-01-01

    In an effort to better understand the control of the formation of branched fatty acids in Micrococcus luteus, the structure of β-ketoacyl-ACP synthase III, which catalyzes the initial step of fatty-acid biosynthesis, has been determined. Micrococcus luteus is a Gram-positive bacterium that produces iso- and anteiso-branched alkenes by the head-to-head condensation of fatty-acid thioesters [coenzyme A (CoA) or acyl carrier protein (ACP)]; this activity is of interest for the production of advanced biofuels. In an effort to better understand the control of the formation of branched fatty acids in M. luteus, the structure of FabH (MlFabH) was determined. FabH, or β-ketoacyl-ACP synthase III, catalyzes the initial step of fatty-acid biosynthesis: the condensation of malonyl-ACP with an acyl-CoA. Analysis of the MlFabH structure provides insights into its substrate selectivity with regard to length and branching of the acyl-CoA. The most structurally divergent region of FabH is the L9 loop region located at the dimer interface, which is involved in the formation of the acyl-binding channel and thus limits the substrate-channel size. The residue Phe336, which is positioned near the catalytic triad, appears to play a major role in branched-substrate selectivity. In addition to structural studies of MlFabH, transcriptional studies of M. luteus were also performed, focusing on the increase in the ratio of anteiso:iso-branched alkenes that was observed during the transition from early to late stationary phase. Gene-expression microarray analysis identified two genes involved in leucine and isoleucine metabolism that may explain this transition

  2. Tinjauan Kritis Terhadap Implementasi Iso 9000

    OpenAIRE

    Purnama, Nursya’bani

    2005-01-01

    ISO 9000 telah diterima secara luas sebagai acuan sistem manajemen kualitas dan penjaminan kualitas. Perusahaan-Perusahaan yang memperoleh sertifikasi ISO dari tahun ke ke tahun mengalami pertumbu¬han yang pesat. Dengan implementasi dan memperoleh sertifikasi ISO 9000, banyak Perusahaan di dunia mem¬peroleh peningkatan kinerja. Meskipun demikian, implementasi ISO 9000 juga dihadapkan pada sejumlah ham¬batan. Implementasi ISO 9000 seringkali dikaitkan dengan Total Quality Management (TQM). Ban...

  3. The stability of iso-α-acids and reduced iso-α-acids in stored blood specimens.

    Science.gov (United States)

    Rodda, Luke N; Gerostamoulos, Dimitri; Drummer, Olaf H

    2014-06-01

    The long-term stability of the iso-α-acids, and three structurally similar but chemically altered iso-α-acids (known as 'reduced iso-α-acids' and consisting of the rho-, tetrahydro- and hexahydro-iso-α-acid groups) were investigated in whole blood. Pools of blank blood spiked with the four beer-specific ingredient congener groups at two different concentration levels were stored at 20°C, 4°C and -20°C; and extracted in duplicate in weeks 1, 3, 5 and 8, using a previously published method. A loss of 15% of the initial concentration was considered to indicate possible instability and losses greater than 30% demonstrated significant losses. The individual analytes within the four iso-α-acid groups were also measured to determine which iso-α-acids were subject to greater degradation and were responsible for the overall group instability. All four iso-α-acid groups showed significant losses after 8 weeks of storage under room temperature conditions in particularly the natural iso-α-acid group where major losses were observed (96% and 85% losses for low and high concentrations, respectively). Some degradation in all iso-α-acid groups were seen at 4°C samples predominantly due to the 'n' analogs of the groups showing an increased instability in blood. The -20°C storage conditions resulted in minimal changes in concentrations of all analytes. Higher than frozen storage temperatures can result in substantial changes on the stability of the iso-α-acid type groups in blood. The aim of this study was to highlight the stabilities of the IAA analytes in order to assist in the interpretation of IAA in stored blood specimens. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. ISO 14000 : environmental management systems

    International Nuclear Information System (INIS)

    Boutin, C.; Emard, C.; Lalonde, G.; Levesque, A.; Robitaille, R.; Rollin, A.L.; Thibeault, I.

    1996-01-01

    This book is addressed to the managers, professionals, and government agents which wish to know the philosophy of the step as well as the stages to be followed for the establishment of a system of environmental management in conformity with the standards of the series ISO 14000. This work locates ISO 14000 in the historical context of its development by describing the bonds with other standards in place of which those of the series ISO 9000. This book answers questions that arise regarding a companies step toward accreditation to ISO 14000

  5. NDT technical assessment for ISO 17025 and ISO 17020 certification

    International Nuclear Information System (INIS)

    Mohamad Pauzi Ismail

    2011-01-01

    ISO 17025 is an international standard that states the requirement criteria for testing and calibration laboratory, while ISO 17020 is for inspection body. Standard Malaysia is the accreditation body for both standards. The author involved in the technical assessment for both standards both in Nuclear Malaysia and outside. The experience in performing NDT assessment activity is explained and discussed. The comparison between both standards is also discussed. (author)

  6. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  7. Explanation and practice on ISO 9000

    International Nuclear Information System (INIS)

    Kwon, Dong Myeong

    2001-01-01

    This book reveals introduction on revision of ISO 9000:2000 with full account and contents of revision and change method change into ISO 9001:2000, the basic principle on ISO 9000:2000 and improvement and aim, definition on explanation, method for detail term, demand for ISO/KS A 9001:2000, quality management system development and transition way, standardization for quality management, manual of quality and making procedure and guide, case of quality manual and procedure and guide and ISO 9001:2000 / KS A 9001:2001 an English-Korean translation.

  8. Laadun- ja riskienhallinta johtamisjärjestelmässä ISO 9001:2015 ja ISO 31000:2009 mukaisesti

    OpenAIRE

    Reinvall, Niko; Karhunen, Joonas

    2015-01-01

    Tämän opinnäytetyön tarkoituksena on tarkastella riskienhallinnan ja laadunhallintajärjestelmien suhdetta ISO 9001:2015 ja ISO 31000:2009-standardien viitekehyksessä, tutkimuskysymyksen ollessa ”miten ja miksi integroida ISO 9001 mukaista laadunhallintaa ja ISO 31000 mukaista riskienhallintaa organisaation johtamisjärjestelmään”. Lisäksi työssä tarkastellaan standardien välisiä yhtymäkohtia ja riskienhallinnan merkitystä ISO 9001:2015 mukaisessa laadunhallintajärjestelmässä. Työn tilaaja...

  9. 75 FR 7581 - RTO/ISO Performance Metrics; Notice Requesting Comments on RTO/ISO Performance Metrics

    Science.gov (United States)

    2010-02-22

    ... performance communicate about the benefits of RTOs and, where appropriate, (2) changes that need to be made to... of staff from all the jurisdictional ISOs/RTOs to develop a set of performance metrics that the ISOs/RTOs will use to report annually to the Commission. Commission staff and representatives from the ISOs...

  10. Optimal Implantation Depth and Adherence to Guidelines on Permanent Pacing to Improve the Results of Transcatheter Aortic Valve Replacement With the Medtronic CoreValve System: The CoreValve Prospective, International, Post-Market ADVANCE-II Study.

    Science.gov (United States)

    Petronio, Anna S; Sinning, Jan-Malte; Van Mieghem, Nicolas; Zucchelli, Giulio; Nickenig, Georg; Bekeredjian, Raffi; Bosmans, Johan; Bedogni, Francesco; Branny, Marian; Stangl, Karl; Kovac, Jan; Schiltgen, Molly; Kraus, Stacia; de Jaegere, Peter

    2015-05-01

    The aim of the CoreValve prospective, international, post-market ADVANCE-II study was to define the rates of conduction disturbances and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement with the Medtronic CoreValve System (Minneapolis, Minnesota) using optimized implantation techniques and application of international guidelines on cardiac pacing. Conduction disturbances are a frequent complication of transcatheter aortic valve replacement. The rates of PPI in the published reports vary according to bioprosthesis type and the indications for PPI. The primary endpoint was the 30-day incidence of PPI with Class I/II indications when the Medtronic CoreValve System was implanted at an optimal depth (≤6 mm below the aortic annulus). The timing and resolution of all new-onset conduction disturbances were analyzed. A total of 194 patients were treated. The overall rate of PPI for Class I/II indications was 18.2%. An optimal depth was reached in 43.2% of patients, with a nonsignificantly lower incidence of PPI in patients with depths ≤6 mm, compared with those with deeper implants (13.3% vs. 21.1%; p = 0.14). In a paired analysis, new-onset left bundle branch block and first-degree atrioventricular block occurred in 45.4% and 39.0% of patients, respectively, and resolved spontaneously within 30 days in 43.2% and 73.9%, respectively. In patients with new PPI, the rate of intrinsic sinus rhythm increased from 25.9% at 7 days to 59.3% at 30 days (p = 0.004). Optimal Medtronic CoreValve System deployment and adherence to international guidelines on cardiac pacing are associated with a lower rate of new PPI after transcatheter aortic valve replacement, compared with results reported in previous studies. (CoreValve Advance-II Study: Prospective International Post-Market Study [ADVANCE II]; NCT01624870). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  12. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  13. Structural characterization of saturated branched chain fatty acid methyl esters by collisional dissociation of molecular ions generated by electron ionization.

    Science.gov (United States)

    Ran-Ressler, Rinat R; Lawrence, Peter; Brenna, J Thomas

    2012-01-01

    Saturated branched chain fatty acids (BCFA) are present as complex mixtures in numerous biological samples. The traditional method for structure elucidation, electron ionization (EI) mass spectrometry, sometimes does not unambiguously enable assignment of branching in isomeric BCFA. Zirrolli and Murphy (Zirrolli , J. A. , and R. A. Murphy. 1993. Low-energy tandem mass spectrometry of the molecular ion derived from fatty acid methyl esters: a novel method for analysis of branched-chain fatty acids. J. Am. Soc. Mass Spectrom. 4: 223-229.) showed that the molecular ions of four BCFA methyl ester (BCFAME) yield highly characteristic fragments upon collisional dissociation using a triple quadrupole instrument. Here, we confirm and extend these results by analysis using a tabletop 3-D ion trap for activated molecular ion EI-MS/MS to 30 BCFAME. iso-BCFAME produces a prominent ion (30-100% of base peak) for [M-43] (M-C₃H₇), corresponding to the terminal isopropyl moiety in the original iso-BCFAME. Anteiso-FAME yield prominent ions (20-100% of base peak) corresponding to losses on both side of the methyl branch, [M-29] and [M-57], and tend to produce more prominent m/z 115 peaks corresponding to a cyclization product around the ester. Dimethyl and tetramethyl FAME, with branches separated by at least one methylene group, yield fragment on both sides of the sites of methyl branches that are more than 6 C away from the carboxyl carbon. EI-MS/MS yields uniquely specific ions that enable highly confident structural identification and quantification of BCFAME.

  14. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  15. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  16. Ventricular Pacing via the Coronary Sinus in a Patient with a Mechanical Tricuspid Valve Prosthesis

    Directory of Open Access Journals (Sweden)

    Janice Swampillai, MD

    2011-01-01

    Full Text Available Implantation of a transvenous endocardial pacing lead in the right ventricle is contra-indicated after mechanical tricuspid valve replacement; therefore a surgical approach to the epicardium is usually required. This case report describes ventricular pacing via a branch of the coronary sinus in a patient with mechanical mitral, aortic and tricuspid valve replacements. In conclusion, this approach is minimally invasive, provides effective ventricular stimulation with low pacing threshold and stable lead position, and is a feasible option when transvenous right ventricular pacing is not possible.

  17. ISO 639-1 and ISO 639-2: International Standards for Language Codes. ISO 15924: International Standard for Names of Scripts.

    Science.gov (United States)

    Byrum, John D.

    This paper describes two international standards for the representation of the names of languages. The first (ISO 639-1), published in 1988, provides two-letter codes for 136 languages and was produced primarily to meet terminological needs. The second (ISO 639-2) appeared in late 1998 and includes three-letter codes for 460 languages. This list…

  18. Structural characterization of saturated branched chain fatty acid methyl esters by collisional dissociation of molecular ions generated by electron ionization[S

    Science.gov (United States)

    Ran-Ressler, Rinat R.; Lawrence, Peter; Brenna, J. Thomas

    2012-01-01

    Saturated branched chain fatty acids (BCFA) are present as complex mixtures in numerous biological samples. The traditional method for structure elucidation, electron ionization (EI) mass spectrometry, sometimes does not unambiguously enable assignment of branching in isomeric BCFA. Zirrolli and Murphy (Zirrolli , J. A. , and R. A. Murphy. 1993. Low-energy tandem mass spectrometry of the molecular ion derived from fatty acid methyl esters: a novel method for analysis of branched-chain fatty acids. J. Am. Soc. Mass Spectrom. 4: 223–229.) showed that the molecular ions of four BCFA methyl ester (BCFAME) yield highly characteristic fragments upon collisional dissociation using a triple quadrupole instrument. Here, we confirm and extend these results by analysis using a tabletop 3-D ion trap for activated molecular ion EI-MS/MS to 30 BCFAME. iso-BCFAME produces a prominent ion (30-100% of base peak) for [M-43] (M-C3H7), corresponding to the terminal isopropyl moiety in the original iso-BCFAME. Anteiso-FAME yield prominent ions (20-100% of base peak) corresponding to losses on both side of the methyl branch, [M-29] and [M-57], and tend to produce more prominent m/z 115 peaks corresponding to a cyclization product around the ester. Dimethyl and tetramethyl FAME, with branches separated by at least one methylene group, yield fragment on both sides of the sites of methyl branches that are more than 6 C away from the carboxyl carbon. EI-MS/MS yields uniquely specific ions that enable highly confident structural identification and quantification of BCFAME. PMID:22021637

  19. [Odd- and branched-chain fatty acids in milk fat--characteristic and health properties].

    Science.gov (United States)

    Adamska, Agata; Rutkowska, Jarosława

    2014-08-22

    This review analyzes the current state of knowledge on odd- and branched-chain fatty acids present in milk fat. Special attention is devoted to the characteristic, synthesis in ruminants, factors affecting their content in milk fat and pro-health properties of these compounds. The group of odd- and branched-chain fatty acids includes mainly saturated fatty acids with one or more methyl branches in the iso or anteiso position. These fatty acids are largely derived from ruminal bacteria and they have been transferred to ruminant tissue (milk and meat). For that reason they have been used as biomarkers of rumen fermentation. Odd- and branched-chain fatty acids are exogenous products for humans, and therefore have specific properties. The results of research from recent decades show that odd- and branched-chain fatty acids have anti-cancer activity. Branched-chain fatty acids may reduce the incidence of necrotizing enterocolitis. Additionally, these compounds have a beneficial effect on proper tissue function and on functioning and development of the infant gut, whereas odd-chain fatty acids are considered as biomarkers of milk fat intake by humans. So far, not all the mechanisms of activity of these compounds are known thoroughly. They should be more carefully studied for application of their biological effects in prevention and treatment.

  20. Control: the effects of ISO

    NARCIS (Netherlands)

    Laura Ilzarbe; PhD Everard van Kemenade; Maria-Jezus Alvarez

    2007-01-01

    De effecten van ISO-certificering zoals gerapporteerd in wetenschappelijk onderzoek. Met speciale aandacht voor de resultaten in het onderwijs. ISO 9000:2000 doet het nadrukkelijk beter dan haar vorige versies.

  1. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  2. International Organization for Standardization (ISO) 15189.

    Science.gov (United States)

    Schneider, Frank; Maurer, Caroline; Friedberg, Richard C

    2017-09-01

    The College of American Pathologists (CAP) offers a suite of laboratory accreditation programs, including one specific to accreditation to the international organization for standardization (ISO) 15189 standard for quality management specific to medical laboratories. CAP leaders offer an overview of ISO 15189 including its components, internal audits, occurrence management, document control, and risk management. The authors provide a comparison of its own ISO 15189 program, CAP 15189, to the CAP Laboratory Accreditation Program. The authors conclude with why laboratories should use ISO 15189. © The Korean Society for Laboratory Medicine.

  3. Experimental study on the thermal stratification in the branch of NPP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Nyung; Hwang, Seong Hong [Kyunghee Univ., Seoul (Korea, Republic of)

    2004-02-15

    As more experience is accumulated in the operation of existing nuclear power plants, the long term effects of thermal-hydraulic phenomena, unaccounted in the original designs, have been observed. One such phenomenon is thermal stratification, which has caused through-wall cracks, thermal fatigue, unexpected piping displacements and pipe support damage. Thermal stratification is a phenomenon as temperature layers are formed in the component or piping due to the density difference between hot and cold water. The thermal stratification phenomena in nuclear power plant observed in the pressurizer surge line, and in the piping of feedwater system, Safety Injection System(SIS), residual heat removal system (or shutdown cooling system), and chemical and volume control system during the design transients. A set of experiment has been performed to predict the temperature distribution in the branch piping of nuclear power plant(Ulchin unit 3 and 4) due to the turbulent penetration, the heat transfer through valve disk and valve leakage. The test facility scaled down to 1/10 has been designed and constructed to simulate the thermal stratification in the piping of safety injection system and shutdown cooling system of Ulchin 3 and 4. The experimental results show that the turbulent penetration depth could be : extended to the end of the vertical pipe, and thermal stratification due to the heat transfer through the valve disk to the end of horizontal pipe behind the valve disk. Finally, thermal stratification could effected by the location of valve leakage.

  4. ISO 9000 Quality Management System

    Science.gov (United States)

    Hadjicostas, Evsevios

    The ISO 9000 series describes a quality management system applicable to any organization. In this chapter we present the requirements of the standard in a way that is as close as possible to the needs of analytical laboratories. The sequence of the requirements follows that in the ISO 9001:2008 standard. In addition, the guidelines for performance improvement set out in the ISO 9004 are reviewed. Both standards should be used as a reference as well as the basis for further elaboration.

  5. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  6. The European Large Area ISO Survey

    DEFF Research Database (Denmark)

    Oliver, S.; Rowan-Robinson, M.; Alexander, D.M.

    2000-01-01

    We describe the European Large Area ISO Survey (ELAIS). ELAIS was the largest single Open Time project conducted by ISO, mapping an area of 12 deg(2) at 15 mu m with ISOCAM and at 90 mu m with ISOPHOT. Secondary surveys in other ISO bands were undertaken by the ELAIS team within the fields of the...

  7. Main steam system piping response under safety/relief valve opening events

    International Nuclear Information System (INIS)

    Swain, E.O.; Esswein, G.A.; Hwang, H.L.; Nieh, C.T.

    1980-01-01

    The stresses in the main steam branch pipe of a Boiling Water Reactor due to safety/relief valve blowdown has been measured from an in situ piping system test. The test results were compared with analytical results. The predicted stresses using the current state of art analytical methods used for BWR SRV discharge transient piping response loads were found to be conservative when compared to the measured stress values. 3 refs

  8. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  9. Mednarodni standardi - veličine in enote (ISO 31-0 do 31-13): International standards - quantities and units (ISO 31-0 to 31-13):

    OpenAIRE

    Glavič, Peter

    2002-01-01

    In this paper the international standards ISO 31 (Quantities and units) are presented with the following parts: ISO 31-0 (General principles), ISO 31-1 (Space and time), ISO 31-2 (Periodic and related phenomena), ISO 31-3 (Mechanics), ISO 31-4 (Heat), ISO 31-5 (Electricity and magnetism), ISO 31-8 (Physical chemistry and molecular physics), ISO 31-12 (Characteristic numbers)and others. The emphasis is given on the basic principles, which is important for writing of reports, presentations, art...

  10. ISO27001 in a Windows Environment

    CERN Document Server

    Honan, Brian

    2010-01-01

    Ideal for project managers, IT and security staff, this book plugs the gap in current guidance literature for ISO27001. ISO27001, the information security management standard (ISMS), is providing a significant challenge for many organisations. One of the key areas of confusion is the relationship between the ISO27001 ISMS project manager and those responsible for implementing the technical controls.

  11. Certification of ISO 9001: SSDL experiences

    International Nuclear Information System (INIS)

    Noriah Mod Ali

    2005-01-01

    Efforts given to maintain the quality management based on the ISO 9000 requirement able to improved the existing system, strengthen the customer confidence and to satisfied the worker needs. It gives direct impact on the harmonization of the Radiation Protection Program in the country. SSDL experiences towards obtaining the the ISO 9002/ISO 9001 certification and its maintenance are discussed in details. (Author)

  12. From ISO 9001:2008 to ISO 9001:2015: Significant changes and their impacts to aspiring organizations

    Science.gov (United States)

    Sari, Y.; Wibisono, E.; Wahyudi, R. D.; Lio, Y.

    2017-11-01

    ISO 9001:2015 is the latest version of ISO Quality Management System standard that has been updated recently from ISO 9001:2008. It is necessary for all organizations that have implemented and been certified with ISO 9001:2008 to prepare the transition and upgrade their Quality Management System because the certification will expire by September 2018. This paper attempts to provide knowledge on the significant changes from ISO 9001:2008 to ISO 9001:2015, what new requirements are added, and how they would impact the organizations. An exploratory and applied research was chosen as the research approach and aimed to explore what transition designs are needed to anticipate the changes as well as their impacts. The research applied a methodology of Plan-Do-Check-Action (PDCA) cycle into four organizations and their results were compared and discussed to explain the transition designs. Some qualitative methods such as observation and interview were used to collect the data. By addressing the new requirements, three transition designs that should be prepared are: (i) identifying needs from interested parties, (ii) analyzing internal and external factors of the organizations to formulate relevant strategies and quality objectives, and (iii) registering risks associated to business processes as well as organizational strategies.

  13. Odd- and branched-chain fatty acids in milk fat – characteristic and health properties

    Directory of Open Access Journals (Sweden)

    Agata Adamska

    2014-08-01

    Full Text Available This review analyzes the current state of knowledge on odd- and branched-chain fatty acids present in milk fat. Special attention is devoted to the characteristic, synthesis in ruminants, factors affecting their content in milk fat and pro-health properties of these compounds. The group of odd- and branched-chain fatty acids includes mainly saturated fatty acids with one or more methyl branches in the iso or anteiso position. These fatty acids are largely derived from ruminal bacteria and they have been transferred to ruminant tissue (milk and meat. For that reason they have been used as biomarkers of rumen fermentation. Odd- and branched-chain fatty acids are exogenous products for humans, and therefore have specific properties. The results of research from recent decades show that odd- and branched-chain fatty acids have anti-cancer activity. Branched-chain fatty acids may reduce the incidence of necrotizing enterocolitis. Additionally, these compounds have a beneficial effect on proper tissue function and on functioning and development of the infant gut, whereas odd-chain fatty acids are considered as biomarkers of milk fat intake by humans. So far, not all the mechanisms of activity of these compounds are known thoroughly. They should be more carefully studied for application of their biological effects in prevention and treatment.

  14. ISO specifications and unclear energy quality certification

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Hun

    2011-12-15

    This book indicates necessity of quality management and change of company environment, basic conception of quality management and thinking way, role of each class for quality management, necessity and purpose of introduction of ISO9000 family, authentication process and construct method of ISO9000 family, authentication effect of ISO9000 family, present condition of ISO9000 family, standard of quality certification and quality management and explanation of 2001 requirement of KSA9000.

  15. ISO specifications and unclear energy quality certification

    International Nuclear Information System (INIS)

    Lee, Tae Hun

    2011-12-01

    This book indicates necessity of quality management and change of company environment, basic conception of quality management and thinking way, role of each class for quality management, necessity and purpose of introduction of ISO9000 family, authentication process and construct method of ISO9000 family, authentication effect of ISO9000 family, present condition of ISO9000 family, standard of quality certification and quality management and explanation of 2001 requirement of KSA9000.

  16. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  17. Adopting ISO 9712:2005 and ISO/IEC 17024:2003 as Philippine national standard for NDT for global competitiveness

    International Nuclear Information System (INIS)

    Banaga, Renato T.; Mateo, Alejandro J.

    2005-01-01

    This paper describes and promotes the adoption of ISO 9712: 2005 edition and the ISO/IEC 17024: 2003 edition by the Philippines to be globally competitive. ISO 9712 is a standard for qualifications and certification of nondestructive testing (NDT) personnel while ISO/IEC 17024 is conformity assessment-general requirements for bodies operating certification of persons. ISO 9712 defies that the effectiveness of an application of nondestructive testing depends on the capabilities and qualifications of personnel performing the NDT test. The Philippines through the national certifying body (NCB) implements the certification of proficiency of NDT personnel in accordance with the Philippine National Standards (PNS-146: 1998) This standard (formerly PNS-146: 1987) was originally based from the draft ISO/TC-135/SC7N35.3 and was later revised to conform to the latest ISO FDIS 9712: 1997 and rename PNS-146: 1998. Now with the issuance of the latest ISO 9712:2005 edition and to keep abreast with the current trends of NDT technology, present time and conditions dictates for us to revise our NDT personnel certification to the latest edition of ISO 9712. The International Atomic Energy Agency (IAEA) supports the establishment of a common NDT standard. The IAEA is promoting af financially supporting the establishment in developing countries of only one NDT standard. The IAEA through the Regional Cooperative Agreement (RCA) has initiated the harmonization of the NDT qualification and certification of personnel in the RCA member states. In October 2001, the IAEA sponsored the Dhaka meeting where the International Committee for Nondestructive Testing (ICNDT), Asia-Pacific Committee (APCNDT) and RCA member states representatives drafted a Mutual Recognition Agreement (MRA) for the Asia-Pacific NDT (APCNDT) personnel certification schemes acording to ISO 9712. Last August 2005, IAEA/RCA sponsored the Colombo meeting for the harmonization of regional NDT applying ISO 9712 and ISO

  18. Extending the Performance of Net Shape Molded Fiber Reinforced Polymer Composite Valves for Use in Internal Combustion Engines

    Science.gov (United States)

    2007-06-01

    fatigue performance of 21 steel and wear surfaces require surface hardening treatments 28. Ceramic and ceramic-head valves have been demonstrated and...0.7- 0.0 6 O2 0.4 010.1 a 0.2 0.4 CA 0.8 1 0 0.1 0.2 02 u 0.4 Oh CA6 0. O hC &0. 313 Case 3: thick-iso-a normalized plots Si IES B8..E4 -4-FO 2.554

  19. Promoting Strong ISO 50001 Outcomes with Supportive National Infrastructure

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee, T.; Siciliano, Graziella; de los Reyes, Pamela

    2015-08-04

    The ISO 50001 standard is a key mechanism for reducing greenhouse gas emissions and improving energy efficiency globally. An increasing number of companies are seeking certification, creating the need for personnel that are competent to conduct ISO 50001 certification audits. The growth of ISO 50001 is expected to accelerate as more companies integrate ISO 50001 into their corporate sustainability strategies and supplier requirements. Robust implementation of ISO 50001 represents an important tool for countries with climate change mitigation goals. Because of its dual focus on continual improvement of an organization’s energy management system (EnMS) and its energy performance improvement, ISO 50001 requires skills of both implementers and certification auditors that are not well-supported by current credentials and training. This paper describes an effort to address skill gaps of certification auditors, a critical factor to ensure that ISO 50001 implementations are robust and result in continued energy performance improvement. A collaboration of governments through the Energy Management Working Group (EMWG), formerly under Global Superior Energy Performance (GSEP), has formed to build workforce capacity for ISO 50001 certification audits. The EMWG is leading the development of an internationally-relevant certification scheme for ISO 50001 Lead Auditor that meets requirements for ISO/IEC 17024 accreditation and ISO 50003 for defining ISO 50001 Lead Auditor competency. Wider availability of competent ISO 50001 Lead Auditors will ultimately increase the impact and market value of ISO 50001 certification and improve consistency of ISO 50001 certification outcomes by establishing a standardized and high level of knowledge and skills globally.

  20. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  1. Improving Earth Science Metadata: Modernizing ncISO

    Science.gov (United States)

    O'Brien, K.; Schweitzer, R.; Neufeld, D.; Burger, E. F.; Signell, R. P.; Arms, S. C.; Wilcox, K.

    2016-12-01

    ncISO is a package of tools developed at NOAA's National Center for Environmental Information (NCEI) that facilitates the generation of ISO 19115-2 metadata from NetCDF data sources. The tool currently exists in two iterations: a command line utility and a web-accessible service within the THREDDS Data Server (TDS). Several projects, including NOAA's Unified Access Framework (UAF), depend upon ncISO to generate the ISO-compliant metadata from their data holdings and use the resulting information to populate discovery tools such as NCEI's ESRI Geoportal and NOAA's data.noaa.gov CKAN system. In addition to generating ISO 19115-2 metadata, the tool calculates a rubric score based on how well the dataset follows the Attribute Conventions for Dataset Discovery (ACDD). The result of this rubric calculation, along with information about what has been included and what is missing is displayed in an HTML document generated by the ncISO software package. Recently ncISO has fallen behind in terms of supporting updates to conventions such updates to the ACDD. With the blessing of the original programmer, NOAA's UAF has been working to modernize the ncISO software base. In addition to upgrading ncISO to utilize version1.3 of the ACDD, we have been working with partners at Unidata and IOOS to unify the tool's code base. In essence, we are merging the command line capabilities into the same software that will now be used by the TDS service, allowing easier updates when conventions such as ACDD are updated in the future. In this presentation, we will discuss the work the UAF project has done to support updated conventions within ncISO, as well as describe how the updated tool is helping to improve metadata throughout the earth and ocean sciences.

  2. Complexing properties of α-iso-saccharinate: thorium

    International Nuclear Information System (INIS)

    Allard, S.; Ekberg, C.

    2005-01-01

    Full text of publication follows: In the alkaline conditions of the intended Swedish repository for long-lived, low to intermediate level waste, SFL3-5, cellulose based items will degrade with iso-saccharinate being the dominant end-product. Iso-saccharinate is a strong complexing agent for tetravalent actinides, as well as for trivalent lanthanides, and its complexation properties are of interest for the long-term repository assessment. In the presented study, the complexation of 234 Th-α-iso-saccharinate is examined using liquid-liquid- extraction and radioanalytical techniques. An organic phase consisting of 0.1 M acetylacetone in toluene was used with a 1.0 M NaClO 4 aqueous phase kept at pH 8 in a thermostated AKUFVE unit. Since the α-iso-saccharinic system consists of three species - the carboxylic α-iso-saccharinic acid, α-iso-saccharinate and α-D-iso-saccharino-1,4-lactone - care must be taken when choosing the operational pH. Keeping the aqueous phase at pH 8 results in negligible concentrations of all but the α-iso-saccharinate form while at the same time being an excellent pH for the 234 Th-acetylacetone complexation with very limited hydrolysis effect. The α- iso-saccharinate concentration was incrementally increased, and samples of equal volumes were taken from the two phases and analyzed in a liquid scintillation detector once the radioactive equilibrium between 234 Th and 234 Pa had been reached. Two complexation constants were used to fit a distribution equation to the experimental data. (authors)

  3. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  4. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  5. ISO standards on the evaluation of contamination

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tamberg, T.A.

    1993-01-01

    The International Organization for Standardization (ISO) develops radiation calibration standards through Subcommittee 2 (titled ''Radiation Protection'') of Technical Committee 85 (ISO/TC85/SC2). The subcommittee has also developed standards providing guidance on the performance of measurements. ISO/TC85/SC2 consists of international technical experts who represent their countries through the international consensus process in providing guidance in several radiation protection areas. The purpose of this paper is to summarize ISO's is guidance provided in the area of contamination measurements

  6. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  7. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  8. Usability evaluation of mobile applications using ISO 9241 and ISO 25062 standards.

    Science.gov (United States)

    Moumane, Karima; Idri, Ali; Abran, Alain

    2016-01-01

    This paper presents an empirical study based on a set of measures to evaluate the usability of mobile applications running on different mobile operating systems, including Android, iOS and Symbian. The aim is to evaluate empirically a framework that we have developed on the use of the Software Quality Standard ISO 9126 in mobile environments, especially the usability characteristic. To do that, 32 users had participated in the experiment and we have used ISO 25062 and ISO 9241 standards for objective measures by working with two widely used mobile applications: Google Apps and Google Maps. The QUIS 7.0 questionnaire have been used to collect measures assessing the users' level of satisfaction when using these two mobile applications. By analyzing the results we highlighted a set of mobile usability issues that are related to the hardware as well as to the software and that need to be taken into account by designers and developers in order to improve the usability of mobile applications.

  9. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  10. [ISO 15189 medical laboratory accreditation].

    Science.gov (United States)

    Aoyagi, Tsutomu

    2004-10-01

    This International Standard, based upon ISO/IEC 17025 and ISO 9001, provides requirements for competence and quality that are particular to medical laboratories. While this International Standard is intended for use throughout the currently recognized disciplines of medical laboratory services, those working in other services and disciplines will also find it useful and appropriate. In addition, bodies engaged in the recognition of the competence of medical laboratories will be able to use this International Standard as the basis for their activities. The Japan Accreditation Board for Conformity Assessment (AB) and the Japanese Committee for Clinical Laboratory Standards (CCLS) are jointly developing the program of accreditation of medical laboratories. ISO 15189 requirements consist of two parts, one is management requirements and the other is technical requirements. The former includes the requirements of all parts of ISO 9001, moreover it includes the requirement of conformity assessment body, for example, impartiality and independence from any other party. The latter includes the requirements of laboratory competence (e.g. personnel, facility, instrument, and examination methods), moreover it requires that laboratories shall participate proficiency testing(s) and laboratories' examination results shall have traceability of measurements and implement uncertainty of measurement. Implementation of ISO 15189 will result in a significant improvement in medical laboratories management system and their technical competence. The accreditation of medical laboratory will improve medical laboratory service and be useful for patients.

  11. Turbulent penetration in T-junction branch lines with leakage flow

    Energy Technology Data Exchange (ETDEWEB)

    Kickhofel, John, E-mail: kickhofel@lke.mavt.ethz.ch; Valori, Valentina, E-mail: v.valori@tudelft.nl; Prasser, H.-M., E-mail: prasser@lke.mavt.ethz.ch

    2014-09-15

    Highlights: • New T-junction facility designed for adiabatic high velocity ratio mixing studies. • Trends in scalar mixing RMS and average in branch line presented and discussed. • Turbulent penetration has unique power spectrum relevant to thermal fatigue. • Forced flow oscillations translate to peaks in power spectrum in branch line. - Abstract: While the study of T-junction mixing with branch velocity ratios of near 1, so called cross flow mixing, is well advanced, to the point of realistic reactor environment fluid–structure interaction experiments and CFD benchmarking, turbulent penetration studies remain an under-researched threat to primary circuit piping. A new facility has been constructed for the express purpose of studying turbulent penetration in branch lines of T-junctions in the context of the high cycle thermal fatigue problem in NPPs. Turbulent penetration, which may be the result of a leaking valve in a branch line or an unisolable branch with heat losses, induces a thermal cycling region which may result in high cycle fatigue damage and failures. Leakage flow experiments have been performed in a perpendicular T-junction in a horizontal orientation with 50 mm diameter main pipe and branch pipe at velocity ratios (main/branch) up to 400. Wire mesh sensors are used as a means of measuring the mixing scalar in adiabatic tests with deionized and tap water. The near-wall region of highest scalar fluctuations is seen to vary circumferentially and in depth in the branch a great deal depending on the velocity ratio. The power spectra of the mixing scalar in the region of turbulent penetration are found to be dominated by high amplitude fluctuations at low frequencies, of particular interest to thermal fatigue. Artificial velocity oscillations in the main pipe manifest in the mixing spectra in the branch line in the form of a peak, the magnitude of which grows with increasing local RMS.

  12. Intermediate species measurement during iso-butanol auto-ignition

    KAUST Repository

    Ji, Weiqi

    2015-10-01

    © 2015 The Combustion Institute.Published by Elsevier Inc. All rights reserved. This work presents the time histories of intermediate species during the auto-ignition of iso-butanol at high pressure and intermediate temperature conditions obtained using a rapid compression machine and recently developed fast sampling system. Iso-butanol ignition delays were acquired for iso-butanol/O2 mixture with an inert/O2 ratio of 7.26, equivalence ratio of 0.4, in the temperature range of 840-950 K and at pressure of 25 bar. Fast sampling and gas chromatography were used to acquire and quantify the intermediate species during the ignition delay of the same mixture at P = 25.3 bar and T = 905 K. The ignition delay times and quantitative measurements of the mole fraction time histories of methane, ethene, propene, iso-butene, iso-butyraldehyde, iso-butanol, and carbon monoxide were compared with predictions from the detailed mechanisms developed by Sarathy et al., Merchant et al., and Cai et al. It is shown that while the Sarathy mechanism well predicts the overall ignition delay time, it overpredicts ethene by a factor of 6-10, underpredicts iso-butene by a factor of 2, and overpredicts iso-butyraldehyde by a factor of 2. Reaction path and sensitivity analyses were carried out to identify the reactions responsible for the observed inadequacy. The rates of iso-butanol hydrogen atom abstraction by OH radical and the beta-scission reactions of hydroxybutyl radicals were updated based on recently published quantum calculation results. Significant improvements were achieved in predicting ignition delay at high pressures (25 and 30 bar) and the species concentrations of ethene and iso-butene. However, the updated mechanism still overpredicts iso-butyraldehyde concentrations. Also, the updated mechanism degrades the prediction in ignition delay at lower pressure (15 bar) compared to the original mechanism developed by Sarathy et al.

  13. Intermediate species measurement during iso-butanol auto-ignition

    KAUST Repository

    Ji, Weiqi; Zhang, Peng; He, Tanjin; Wang, Zhi; Tao, Ling; He, Xin; Law, Chung K.

    2015-01-01

    © 2015 The Combustion Institute.Published by Elsevier Inc. All rights reserved. This work presents the time histories of intermediate species during the auto-ignition of iso-butanol at high pressure and intermediate temperature conditions obtained using a rapid compression machine and recently developed fast sampling system. Iso-butanol ignition delays were acquired for iso-butanol/O2 mixture with an inert/O2 ratio of 7.26, equivalence ratio of 0.4, in the temperature range of 840-950 K and at pressure of 25 bar. Fast sampling and gas chromatography were used to acquire and quantify the intermediate species during the ignition delay of the same mixture at P = 25.3 bar and T = 905 K. The ignition delay times and quantitative measurements of the mole fraction time histories of methane, ethene, propene, iso-butene, iso-butyraldehyde, iso-butanol, and carbon monoxide were compared with predictions from the detailed mechanisms developed by Sarathy et al., Merchant et al., and Cai et al. It is shown that while the Sarathy mechanism well predicts the overall ignition delay time, it overpredicts ethene by a factor of 6-10, underpredicts iso-butene by a factor of 2, and overpredicts iso-butyraldehyde by a factor of 2. Reaction path and sensitivity analyses were carried out to identify the reactions responsible for the observed inadequacy. The rates of iso-butanol hydrogen atom abstraction by OH radical and the beta-scission reactions of hydroxybutyl radicals were updated based on recently published quantum calculation results. Significant improvements were achieved in predicting ignition delay at high pressures (25 and 30 bar) and the species concentrations of ethene and iso-butene. However, the updated mechanism still overpredicts iso-butyraldehyde concentrations. Also, the updated mechanism degrades the prediction in ignition delay at lower pressure (15 bar) compared to the original mechanism developed by Sarathy et al.

  14. Aplikace ISO norem v oblasti vývoje softwaru

    OpenAIRE

    Ullrich, Jan

    2007-01-01

    Thesis evaluates ISO standars used for software developement and their relationship to methodologies. It also describes processes according to international standard ISO/IEC 12207 and quality management systems according to ISO 9000. It evaluates also mothodlogy RUP and agile methodollogies. The goal of the thesis to tailor processes related to ISO 9001 to be compliant to the ISO/IEC 12207 in a small company.

  15. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  16. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  17. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  18. Peningkatan Mutu Proses Perguruan Tinggi Melalui Sistem Mutu Iso 9000

    Directory of Open Access Journals (Sweden)

    Th. Widia Soerjaningsih

    2004-09-01

    Full Text Available Article was made to answer these several questions;  what is acreditation and the application in the college; what is ISO 9000 quality system; why is ISO 9000 needed by the college; how ISO 9000 can support the achievement of the defined quality level; how ISO  9000 guarantee the achievement of BAN target including quality, efficiency, and relevance; what is the difference between BAN Acreditation and ISO 9000 Certification; ISO 9000 Consultant: why it is necessary, how to choose it, the line of the contract; ISO 9000 Assessor and the achieve certification: SGS and etc.; and ISO 9000 Certification Proccess Cost Aspect.   

  19. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  20. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  1. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    Science.gov (United States)

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  2. ISO science - observations of dusty discs.

    Science.gov (United States)

    Heske, A.

    1992-12-01

    ISO, the Infrared Space Observatory, will be an infrared observing facility in space. Via submission of observing proposals, use of this facility will be open to the astronomical community. The scientific payload consists of two spectrometers, a camera and a photo-polarimeter. Following an overview of the ISO mission, this paper describes the highlights of the Central Programme - proposals which are being prepared by the instrument groups, the mission scientists and the astronomers of the ISO Science Operations Team - with special emphasis on the proposals concerned with dusty discs.

  3. Launching the chaotic realm of iso-fractals: A short remark

    Energy Technology Data Exchange (ETDEWEB)

    O' Schmidt, Nathan [Department of Mathematics, Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Katebi, Reza [Department of Physics, California State University in Fullerton, 800 North State College Boulevard, Fullerton, CA 92831 (United States); Corda, Christian [Institute for Theoretical Physics and Advanced Mathematics Einstein-Galilei (IFM), Via Santa Gonda 14, 59100 Prato (Italy)

    2015-03-10

    In this brief note, we introduce the new, emerging sub-discipline of iso-fractals by highlighting and discussing the preliminary results of recent works. First, we note the abundance of fractal, chaotic, non-linear, and self-similar structures in nature while emphasizing the importance of studying such systems because fractal geometry is the language of chaos. Second, we outline the iso-fractal generalization of the Mandelbrot set to exemplify the newly generated Mandelbrot iso-sets. Third, we present the cutting-edge notion of dynamic iso-spaces and explain how a mathematical space can be iso-topically lifted with iso-unit functions that (continuously or discretely) change; in the discrete case examples, we mention that iteratively generated sequences like Fibonacci’s numbers and (the complex moduli of) Mandelbrot’s numbers can supply a deterministic chain of iso-units to construct an ordered series of (magnified and/or de-magnified) iso-spaces that are locally iso-morphic. Fourth, we consider the initiation of iso-fractals with Inopin’s holographic ring (IHR) topology and fractional statistics for 2D and 3D iso-spaces. In total, the reviewed iso-fractal results are a significant improvement over traditional fractals because the application of Santilli’s iso-mathematics arms us an extra degree of freedom for attacking problems in chaos. Finally, we conclude by proposing some questions and ideas for future research work.

  4. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  5. DETAILED CHEMICAL KINETIC MODELING OF ISO-OCTANE SI-HCCI TRANSITION

    Energy Technology Data Exchange (ETDEWEB)

    Havstad, M A; Aceves, S M; McNenly, M J; Piggott, W T; Edwards, K D; Wagner, R M; Daw, C S; Finney, C A

    2009-10-12

    The authors describe a CHEMKIN-based multi-zone model that simulates the expected combustion variations in a single-cylinder engine fueled with iso-octane as the engine transitions from spark-ignited (ST) combustion to homogeneous charge compression ignition (HCCI) combustion. The model includes a 63-species reaction mechanism and mass and energy balances for the cylinder and the exhaust flow. For this study they assumed that the SI-to-HCCI transition is implemented by means of increasing the internal exhaust gas recirculation (EGR) at constant engine speed. This transition scneario is consistent with that implemented in previously reported experimental measurements on an experimental engine equipped with variable valve actuation. They find that the model captures many of the important experimental trends, including stable SI combustion at low EGR ({approx} 0.10), a transition to highly unstable combustion at intermediate EGR, and finally stable HCCI combustion at very high EGR ({approx} 0.75). Remaining differences between the predicted and experimental instability patterns indicate that there is further room for model improvement.

  6. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  7. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  8. Lessons learned with ISO 14001 at DOE sites

    Energy Technology Data Exchange (ETDEWEB)

    Wilkinson, C. H., LLNL

    1998-03-01

    ISO 14001 is the international standard for environmental management systems (EMS). The standard applies the `plan, do, check, act` management system model to assure that the environmental impacts of operations are fully considered in planning and facility operations. ISO 14001 has grown in popularity in both the public and the private sector and has seen increasing utility within the U.S. Department of Energy (DOE). While there is no final DOE policy or requirement for ISO 14001 EMS implementation, ISO 14001 commands an active presence at many DOE sites. In general, the impetus for ISO 14001 in the DOE complex has been either an initiative by site management contractors to improve performance, or an actual requirement in the new management contracts for the sites. Several DOE sites now are committed to implement EMS`s in conformance with ISO 14001: Brookhaven National Laboratory (BNL), Hanford, Idaho National Engineering and Environmental Laboratory (INEEL), Kansas City Plant, Nevada Test Site, Savannah River Site (SRS), Waste Isolation Pilot Project (WIPP), West Valley. Several other DOE sites are expected to proceed in the near future with an EMS consistent with ISO 14001. However, not all sites are proceeding with an ISO 14001 EMS based on individual site business considerations. This paper describes the status of EMS implementation at these sites and identifies lessons learned that may be of use to other DOE sites.

  9. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. The international ISOE programme. ISOE IAEA technical centre activities

    International Nuclear Information System (INIS)

    Gustafsson, M.

    1996-01-01

    The objective of the sub-programme on Occupational Radiation Protection in the International Atomic Energy Agency, IAEA, is to promote a harmonized approach to optimizing occupational radiation protection by developing guidelines for controlling radiation doses in the workplace and on current occupational radiation protection techniques. A significant part of this programme is the provision of assistance to developing member states to bring their radiation safety infrastructure to an appropriate level for the usage of radiation in the state. In consistence with these objectives the IAEA has been involved with the ISOE programme from its inception and has contributed actively to its growth. In 1993 an arrangement was agreed between the IAEA and the Nuclear Energy Agency, NEA, by which the IAEA co-sponsors ISOE inviting those IAEA member states which are not members of the NEA to participate cost-free in the programme. (author)

  11. Studies on extraction behavior of U(VI) and Th(IV) from nitric acid medium using tri-iso-amyl phosphate (TiAP)/ n-dodecane as extractant

    International Nuclear Information System (INIS)

    Jadhav, S.T.; Tripathi, S.C.; Singh, S.K.; Gandhi, P.M.; Janardan, P.

    2012-01-01

    Tri-iso-amyl phosphate is a higher homologue of TBP, retaining many advantages of TBP while eliminating or mitigating its disadvantages. Its longer, branched alkyl chain, resists third phase formation during overloading of actinides. The TiAP is being considered as an alternative of TBP for the reprocessing of Fast Breeder Reactor fuels due to its various advantages over TBP

  12. A graded approach to ISO 9000 implementation for records managers

    Energy Technology Data Exchange (ETDEWEB)

    Pasterczyk, C.E.

    1994-08-01

    ISO 9000 is a series of quality system standards developed by Technical Committee 176 of the International Standards Organization. The series includes three standards, ISO 9001 `Quality systems--Model for quality assurance in design/development, production, installation and serving,` ISO 9002 `Quality systems--Model for quality assurance in production and installation,` ISO 9003 `Quality systems--Model for quality assurance in final inspection and test,` and two guidelines, ISO 9000 `Quality management and quality assurance standards` and ISO 9004 `Quality management and quality system elements--Guidelines.` In companies with quality programs already in place, the structure of the ISO series lends itself to augmenting those policies, procedures, and instructions where problems exist or where the risks of failure are greater. The objectives of this paper are to provide a basic familiarity to ISO 9000 and quality assurance concepts; provide a higher level of familiarity to the records management and document control portions of the ISO 9000 series; and to discuss a graded approach to meeting the intent of ISO 9000.

  13. ISO 14001

    DEFF Research Database (Denmark)

    Jørgensen, Tine Herreborg

    2004-01-01

    The aim of this paper is to discuss a number of issues related to ISO 14001, the international standard for environmental management systems (EMS). The standard is a process standard that leaves room for interpretation at company level as well as among lead auditors from certifying bodies...

  14. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  15. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  16. Risk in Management Systems according to ISO standard

    Directory of Open Access Journals (Sweden)

    P. Królas

    2010-07-01

    Full Text Available The purpose of this article was to present selected management standards in context of risk management. It presents main ISOmanagement standards (ISO 9001, ISO 14001, OHSAS 18001, ISO 27001, BS 25999, ISO 31000 that apply to polish enterprises. In thefirst part of this article there are analyzed management standards regarding quality, environment, occupational health and safety,information security, as well as business continuity management and risk management. The second part of the article discusses the processof dealing with risk based on chosen management standard.

  17. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  18. Implementation and Impact of ISO 9001

    NARCIS (Netherlands)

    B. Manders (Basak)

    2015-01-01

    markdownabstract__Abstract __ The ISO 9001 quality management standard has been implemented by more than one million organizations in 187 countries since its introduction in 1987. A newer version of ISO 9001 is planned to be introduced in 2015. Even though it is widely used by organizations to

  19. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  20. The new international standard ISO 14001: 2004 environmental management system

    International Nuclear Information System (INIS)

    Oheba, Jamal Basher

    2006-01-01

    ISO 14001 is one standard in the ISO 14000 series of standards developed by International Organization of Standardization (ISO). Since it was published in 19096, it has rapidly become the most important environmental standard in the world. ISO 14001 is an environmental management system (EMS) that can be classified into environmental technologies provides a systematic procedure to all kind of organizations to prevent pollutions, protect environment and to improve their overall environmental performance. This new standard ISO 14001 2004 was published on November 15, 2004. It cancels and replaced the old ISO 14001-1996. Because the important of the previous standard for our local industries, firms, ...etc, this paper presents ISO 14001 concepts, issues, benefits and focuses on the stages of implementation to achieve ISO 14001-2004 certification which includes general requirements environmental policy, planning (objectives, targets ..), implementation and operations, checking and management review ...etc and presents how to apply isotop time saver software to design records, and to save time to implement ISO 14001 2004 and finally a conclusion is provided.(Author)

  1. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  2. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  3. Application Security in the ISO27001 Environment

    CERN Document Server

    Vinod, Vasudevan; Firosh, Ummer

    2008-01-01

    Application Security in the ISO27001 Environment demonstrates how to secure software applications within a best practice ISO/IEC 27001 environment and supports implementation of the PCI DSS Payment Application Security Standard.

  4. Tietoturvallisuusauditointi ISO 27000-viitekehyksessä

    OpenAIRE

    Luoma, Ilmari

    2015-01-01

    Tiedon olemassaolo eri olomuodoissa muodostaa vaikeasti hallittavan uhkakentän, jonka käsittelyyn kansainvälisesti hyväksytty ISO 27000 -standardi on hyvä väline. Työn tarkoitus on perehtyä ISO/IEC 27000 -standardisarjaan, soveltaa standardin vaatimuksia laatimalla tietoturvallisuuden auditointiaineisto ja -menetelmä, sekä toteuttaa tietoturvallisuusauditointi käytännössä. Työssä esitellään tietoturvallisuuden kytkeytyminen yritysturvallisuuteen, tietoturvallisuuden osa-alueittainen ...

  5. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  6. PENGGABUNGAN PENERAPAN SISTEM JAMINAN MUTU ISO 9001:2008 DAN SISTEM HACCP KE DALAM SISTEM MANAJEMEN KEAMANAN PANGAN ISO 22000:2009 (STUDI KASUS DI PT INDOKOM SAMUDRA PERSADA [The Merger of Quality Assurance System ISO 9001:2008 and HACCP system into Food

    Directory of Open Access Journals (Sweden)

    Novri Ilmiawan

    2014-10-01

    Full Text Available The object of this research was to merge the application of HACCP system and ISO 9001:2008 in ISP company into ISO 22000:2009. The  research method used was case study method. The study was conducted on three stages. The first was the arrangement gap analysis conducted by comparing the conditions of the company with ISO 22000:2009 standards. The second was by observing sanitation and pre requisite programs. The third was by observing traceability system. The data in this research were reported descriptively, consisted of ISO 9001:2008 and HACCP application in the company and the gaps of principles in ISO 22000:2009 toward ISO 9001:2008 and HACCP. The result showed that ISP company has applied 12 steps which covered in HACCP system, and also the ISO 9001 system were appropriate with ISO 9001:2008 standards in every clauses. Pre requisite program (GMP and SSOP have been effectively applied. GMP in ISP company is categorized on the first spot (excellent. The eight keys of SSOP have been fulfilled. ISP company has been fulfilling 54 from 57 (94.74% criteria in ISO 22000:2009 standards, yet there still several things needed to be improved, which are the quality manual content  and HACCP table plan and its monitoring. The  traceability system has been applied well in ISP. Keywords : HACCP, ISO 9001, ISO 22000, GMP, SSOP.

  7. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    NARCIS (Netherlands)

    Tomsic, Anton; Li, Wilson W. L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A. J. M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred

  8. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  9. ADOPTION OF ISO 9001 QUALITY MANAGEMENT STANDARD IN AFRICA

    Directory of Open Access Journals (Sweden)

    Erlantz Allur

    2014-03-01

    Full Text Available This article analyzes the dissemination of ISO 9001, the main global management standards, within Africa. The work refers to the diffusion of ISO 9001 standard in terms of its certification intensity. In this article, the dissemination of ISO 9001 in Africa has been analyzed. The findings reveal that the diffusion of the standard in this continent is not very relevant, what might be seen as an indicator of the process of Africa's trade marginalization in the age of globalization. The general certification intensity of the continet is of 0.18; in other words, the proportion of the contribution of Africa to the global GDP of the world is more than five times superior to the proportion of ISO 9001 certificates located in Africa. By means of the logistic model the dissemination of ISO 9001 is forecasted, and it has been observed that the diffusion of ISO 9001 in Africa is in an 85% of its saturation point. Taking into account this model, it's expected that the dissemination of ISO 9001 will be growing until 2020.

  10. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    Science.gov (United States)

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Verification the 25-kgy dose using the iso standard iso/tr 13409 for the production of bone grafts

    International Nuclear Information System (INIS)

    Otero, I.; Barrera, L.; Diaz, A.; Napoles, D.; Sanchez, E

    2001-01-01

    The purpose of this work was to verify the 25 Gy dose using the ISO standard ISO/TR 13409 for the production of bone grafts from the Tissue Bank ORTOP of the Complejo Cientifico Ortopedico Internacional Frank Pais. We performed two principal microbiological activities: bioburden estimate, pre-sterilization count plus a compensation for the efficiency of the recovery method, by ISO 11737-1 and test of sterility by ISO 11737-2. The techniques for Bioburden estimation could be direct or indirect. Choice of direct vs. indirect depends on number of contaminating micro-organisms, product configuration, ability to remove microbial contamination, effect of removal method on microbial viability, types and location of micro-organisms, nature of product and culture conditions. For a test of sterility, he product unit or SIP putted direct immersion in educated culture medium and incubate. Keep precaution to minimize level to the false positives is necessary

  12. ISO 9001 quality management systems

    CERN Document Server

    Natarajan, Dhanasekharan

    2017-01-01

    This book explains the requirements of ISO 9001 for establishing quality management system (QMS) for an organization. The requirements are illustrated with examples from industries for understanding the requirements and preparing the documents of QMS with high clarity. Methods of integrating ISO 9001 requirements with enterprise resource planning (ERP) software are presented. The software integrated approach enables process owners to focus on their core tasks of achieving the planned outputs of processes and the software generates quality records automatically.

  13. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    International Nuclear Information System (INIS)

    Park, Sung Hwan

    2009-01-01

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  14. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  15. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  16. Lean principles adoption in environmental management system (EMS - ISO 14001

    Directory of Open Access Journals (Sweden)

    Perumal Puvanasvaran

    2012-12-01

    Full Text Available Purpose: The purpose of this study is to examine the characteristic of the lean principles into ISO 14001 and to propose linkage of the lean principles and ISO 14001.Design/methodology/approach: To achieve the objective of the study, literature survey and quantitative research method using questionnaires survey are used.Findings and Originality/value: The findings of this study confirm that ISO 14001 certified company adopted lean production practices.  The study also proves that lean principles have positive and significant relationship with ISO 14001 EMS and the linkage can be made between lean principles and ISO 14001 to achieve Continual Improvement.Research limitations/implications: The small sizes of the sample of the participating companies are the main limitations of this study and this research mainly focuses on the manufacturing environment and services industry.Practical implications: This research show that all ISO 14001 companies do adopt at least one lean production practices and the main findings are lean principles has positive and highly significant relationship with ISO 14001 requirements.  This is because the integration of lean principles into ISO 14001 will serve practical methods for ISO14001 EMS to achieve the continual improvement.Originality/value: This research is amongst the first to study the combined lean principles with ISO 1400.  Based on the current situation, there is no integration within this two management system. 

  17. Standardization of Image Quality Analysis – ISO 19264

    DEFF Research Database (Denmark)

    Wüller, Dietmar; Kejser, Ulla Bøgvad

    2016-01-01

    There are a variety of image quality analysis tools available for the archiving world, which are based on different test charts and analysis algorithms. ISO has formed a working group in 2012 to harmonize these approaches and create a standard way of analyzing the image quality for archiving...... systems. This has resulted in three documents that have been or are going to be published soon. ISO 19262 defines the terms used in the area of image capture to unify the language. ISO 19263 describes the workflow issues and provides detailed information on how the measurements are done. Last...... but not least ISO 19264 describes the measurements in detail and provides aims and tolerance levels for the different aspects. This paper will present the new ISO 19264 technical specification to analyze image quality based on a single capture of a multi-pattern test chart, and discuss the reasoning behind its...

  18. Numerical simulations of pressure fluctuations at branch piping in BWR main steam line

    International Nuclear Information System (INIS)

    Morita, Ryo; Inada, Fumio; Yoshikawa, Kazuhiro; Takahashi, Shiro

    2009-01-01

    The power uprating of a nuclear power plant may increase/accelerate degradation phenomena such as flow-induced vibration and wall thinking. A steam dryer was damaged by a high cycle fatigue due to an acoustic-induced vibration at the branch piping of safety relief valves (SRVs) in main steam lines. In this study, we conducted the numerical simulations of steam/air flow around a simplified branch piping to clarify the basic characteristics of resonance. LES simulations were conducted in ordinary pressure/temperature air and steam under BWR plant conditions. In both cases, the excitation of the pressure fluctuations at the branch was observed under some inlet velocity conditions. These fluctuations and inlet conditions were normalized and the obtained results were compared. The normalized results showed that the range and maximum amplitude of pressure fluctuations were almost the same in low-pressure/temperature air and high-pressure/temperature steam. We found that ordinary pressure/temperature air experiments and simulations can possibly clarify the characteristics of the resonance in high-pressure/temperature steam. (author)

  19. Twenty new ISO standards on dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Farrar IV, H.

    2000-01-01

    Twenty standards on essentially all aspects of dosimetry for radiation processing were published as new ISO standards in December 1998. The standards are based on 20 standard practices and guides developed over the past 14 years by Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). The transformation to ISO standards using the 'fast track' process under ISO Technical Committee 85 (ISO/TC85) commenced in 1995 and resulted in some overlap of technical information between three of the new standards and the existing ISO Standard 11137 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. Although the technical information in these four standards was consistent, compromise wording in the scopes of the three new ISO standards to establish precedence for use were adopted. Two of the new ISO standards are specifically for food irradiation applications, but the majority apply to all forms of gamma, X-ray, and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruit, vegetables, meats, spices, processed foods, plastics, inks, medical wastes, and paper. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties using the new ISO Type A and Type B evaluations. Unfortunately, nine of the 20 standards just adopted by the ISO are not the most recent versions of these standards and are therefore already out of date. To help solve this problem, efforts are being made to develop procedures to coordinate the ASTM and ISO development and revision processes for these and future ASTM-originating dosimetry standards. In the meantime, an additional four dosimetry standards have recently been published by the ASTM but have

  20. A Stepwise ISO-Based TQM Implementation Approach Using ISO 9001:2015

    Directory of Open Access Journals (Sweden)

    Chen Chi-kuang

    2016-12-01

    Full Text Available The lack of an implementation roadmap always deters enterprises from choosing Total Quality Management (TQM as its major management approach. This paper proposes a stepwise ISO-based TQM implementation approach which is based on the notion of the new three-dimensional overall business excellence framework developed by Dahlgaard et al. [1]. The proposed approach consists of nine steps comprising three categories: “TQM faith building”, “TQM tools and techniques learning”, and “system development”. The steps in each of the three categories are arranged to span across the proposed nine-step approach. The ISO 9001:2015 standard is used as a case study to demonstrate the proposed approach. The ideas and benefits of the proposed approach are further discussed in relation to this illustration.

  1. New ISO standard - personnel photographic film dosemeters

    International Nuclear Information System (INIS)

    Brabec, D.

    1980-01-01

    The ISO Standard 1757 ''Personnel Photographic Film Dosemeters'', issued in June 1980, is briefly described. UVVVR's own dosemeter developed for use in the national film dosimetry service in Czechoslovakia is evaluated in relation to this ISO Standard. (author)

  2. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  3. AREVA's innovative solutions for valve diagnostics and in-situ valve repair

    International Nuclear Information System (INIS)

    Damies, H.; Breitenberger, U.; Munoz, L.; Kostroun, F.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions can support that in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. More than 25 years of experience in various plants worldwide show that application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. With the innovative AVARIS technology an in-situ valve repair is possible. It has the unique ability to conduct several steps in-situ, to maintain the sealing seat of gate or check valves. By applying AVARIS, the valve is restored in its original state, the system remains unchanged. Thus, all original documents remain valid and applicable. In comparison to previous procedures like cutting valves out of the pipeline and repairing hard facings or damaged seal seats in a separate workshop or alternatively replacement by a new valve body the new AVARIS technology avoids costs, risk and effort. (author)

  4. SINERGI ISO 9001:2000 - CMMI PADA INDUSTRI PENGEMBANG PERANGKAT LUNAK

    Directory of Open Access Journals (Sweden)

    Leo Willyanto Santoso

    2005-01-01

    Full Text Available All sectors of society including softwere industry, have a big concern about quality, both of product quality and service quality. The need to manage risk, has a strong relation with quality and increases system complexity. Standarization in determining quality, ISO is a must for all software developer. If we study further, ISO 9001:2000 still has some weakness especially for implementation in software product. This paper presents a comparative analysis of quality approaches to risk management. This paper also provide a general overview of all the risks aspects treated in ISO 9001:2000 standards and CMMI model version 1.1. In this research, we obtain a strategy to implement ISO 9001:2000 and CMMI together when we make a planing to increase software process. Besides it produces analysis how to change position from ISO 9001:2000 to CMMI. In the implementation on software industry PT 'X', obtain get various benefits that has never been obtained before. Abstract in Bahasa Indonesia : Semua hal dalam hidup ini selalu memperhatikan masalah kualitas, baik itu berupa kualitas produk ataupun kualitas layanan. Pada industri perangkat lunak, hal ini tidak dibedakan, kebutuhan untuk menghasilkan produk yang berkualitas akan meningkatkan kekompleksan dari sebuah sistem. Standarisasi dalam penentuan kualitas, ISO sudah menjadi keharusan bagi para pengembang perangkat lunak. Apabila diteliti lebih lanjut, ISO 9001:2000 masih mempunyai banyak kekurangan, khususnya untuk diaplikasikan dalam produk perangkat lunak.Pada penelitian ini, akan dibahas analisis perbandingan dengan melakukan pendekatan kualitas untuk meningkatkan proses perangkat lunak dengan melakukan mapping antara ISO 9001:2000 dengan CMMI. Hal-hal yang dibahas berupa aspek-aspek dari standard ISO dan CMMI versi 1.1. Pada penelitian ini, dapat diperoleh strategi untuk menerapkan ISO 9001:2000 dan CMMI secara sinergi ketika merencanakan untuk melakukan peningkatan proses perangkat lunak. Selain itu

  5. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  6. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural......%) were treated conservatively and 1 with surgery. Four patients (22%) died from endocarditis or complications to treatment, 2 of those (11%) during initial hospitalization for PVE. An increased risk of TAVI-PVE was seen in patients with low implanted valve position (hazard ratio, 2.8 [1.1-7.2]), moderate...

  7. An introduction to information security and ISO27001:2013

    CERN Document Server

    Watkins, Steve

    2013-01-01

    Up to date with the latest version of the Standard (ISO27001:2013), An Introduction to information security and ISO27001:2013 is the perfect solution for anyone wanting an accurate, fast, easy-to-read primer on information security from an acknowledged expert on ISO27001.

  8. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  9. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  10. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  11. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  12. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  13. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  14. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  15. Comparative study between CardiaMed valves (freely floating valve leaflets versus St. Jude Medical (fixed valve leaflets in mitral valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Mostafa Ahmed

    2017-09-01

    Conclusions: CardiaMed freely floating leaflet prostheses showed good hemodynamic characteristics. The prosthesis adequately corrects hemodynamics and is safe and no worse than the St. Jude Medical valve in the mitral valve position.

  16. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.

    Science.gov (United States)

    Rampat, Rajiv; Khawaja, M Zeeshan; Hilling-Smith, Roland; Byrne, Jonathan; MacCarthy, Philip; Blackman, Daniel J; Krishnamurthy, Arvindra; Gunarathne, Ashan; Kovac, Jan; Banning, Adrian; Kharbanda, Raj; Firoozi, Sami; Brecker, Stephen; Redwood, Simon; Bapat, Vinayak; Mullen, Michael; Aggarwal, Suneil; Manoharan, Ganesh; Spence, Mark S; Khogali, Saib; Dooley, Maureen; Cockburn, James; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-06-26

    The authors report the incidence of pacemaker implantation up to hospital discharge and the factors influencing pacing rate following implantation of the LOTUS bioprosthesis (Boston Scientific, Natick, Massachusetts) in the United Kingdom. Transcatheter aortic valve replacement (TAVR) is associated with a significant need for permanent pacemaker implantation. Pacing rates vary according to the device used. The REPRISE II (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System) trial reported a pacing rate of 29% at 30 days after implantation of the LOTUS device. Data were collected retrospectively on 228 patients who had the LOTUS device implanted between March 2013 and February 2015 across 10 centers in the United Kingdom. Twenty-seven patients (12%) had pacemakers implanted pre-procedure and were excluded from the analysis. Patients were aged 81.2 ± 7.7 years; 50.7% were male. The mean pre-procedural QRS duration was 101.7 ± 20.4 ms. More than one-half of the cohort (n = 111, 55%) developed new left bundle branch block (LBBB) following the procedure. Permanent pacemakers were implanted in 64 patients (32%) with a median time to insertion of 3.0 ± 3.4 days. Chief indications for pacing were atrioventricular (AV) block (n = 46, 72%), or LBBB with 1st degree AV block (n = 11, 17%). Amongst those who received a pacemaker following TAVR the pre-procedural electrocardiogram findings included: No conduction disturbance (n = 41, 64%); 1st degree AV block (n = 10, 16%); right bundle branch block (n = 6, 9%) and LBBB (n = 5, 8%). LBBB (but not permanent pacemaker) occurred more frequently in patients who had balloon aortic valvuloplasty before TAVR (odds ratio [OR]: 1.25; p = 0.03). Pre-procedural conduction abnormality (composite of 1st degree AV block, hemiblock, right bundle branch block, LBBB) was independently associated with the need for permanent pacemaker (OR: 2.54; p = 0.048). The absence of

  17. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  18. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  19. Information security risk management for ISO27001/ISO27002

    CERN Document Server

    Calder, A; Watkins, S

    2010-01-01

    Drawing on international best practice, including ISO/IEC 27005, NIST SP800-30 and BS7799-3, the book explains in practical detail how to carry out an information security risk assessment. It covers key topics, such as risk scales, threats and vulnerabilities, selection of controls, and roles and responsibilities, and includes advice on choosing risk assessment software.

  20. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  1. Supra-annular valve strategy for an early degenerated transcatheter balloon-expandable heart valve.

    Science.gov (United States)

    Kamioka, Norihiko; Caughron, Hope; Corrigan, Frank; Block, Peter; Babaliaros, Vasilis

    2018-01-23

    Currently, there are no recommendations regarding the selection of valve type for a transcatheter heart valve (THV)-in-THV procedure. A supra-annular valve design may be superior in that it results in a larger effective orifice area and may have a lower chance of valve thrombosis after THV-in-THV. In this report, we describe the use of a supra-annular valve strategy for an early degenerated THV. © 2018 Wiley Periodicals, Inc.

  2. ISO 9001 2000 : the quality management process

    CERN Document Server

    Tricker, Ray

    2006-01-01

    With the publication of ISO 9001:2000, there is now a single quality management ?requirements? standard that is applicable to all organisations, products and services. ISO 9001:2000 is the only standard that can be used for the certification of a QMS and its generic requirements can be used by any organisation.ISO 9001:2000 applies to all types or organisations. It is the quality standard which specifies the requirements of quality management systems for use where organisations need to demonstrate their capability to provide products and services which meet both customer needs and relevant reg

  3. [ISO 9001:2015 Certification in Quality Management].

    Science.gov (United States)

    Enders, Christian; Lang, Gabriele E; Lang, Gerhard K; Werner, Jens Ulrich

    2017-07-01

    Quality management improves the structures, processes and results of organizations of all kinds. Many practices and clinics have their existing quality management system certified according to ISO 9001, (e.g., to check their own quality management system or to obtain a testimonial against third parties). The latest version ISO 9001:2015 contains some changes, both structurally and in terms of content. These changes can be met with reasonable efforts. An ISO 9001:2015 certification represents a value for your organization, but these advantages are often not directly measurable. Georg Thieme Verlag KG Stuttgart · New York.

  4. ISO 9001 and ISO 14001: An Integrated Quality Management System for an MTR Facility SAFARI-1 Research Reactor

    International Nuclear Information System (INIS)

    Du Bruyn, J.F.; Piani, C.S.B.

    2005-01-01

    The SAFARI-1 research reactor, owned and operated by the South African Nuclear Energy Corporation (Necsa), initially obtained ISO 9001 accreditation of its Quality, Health, Safety and Environmental (QHSE) management system via international affiliation from the South African Bureau of Standards (SABS) during 1998 and re-certification according to ISO 9001 (2000) in 2003. With ever-increasing demands on nuclear facilities to demonstrate conformance to environmental policies, SAFARI-1 has now developed an Environmental Management System (EMS) that is compliant with ISO 14001 (1996) and is fully integrated with the SAFARI-1 Quality Management System (QMS). The dynamic involvement of SAFARI-1 in commercial applications demanded that any transition of the original QMS to a fully incorporated QHSE system had to be done in a way that would ensure sustained delivery of a safe and reliable service with continuous quality. At the same time, the primary vision of operating a facility under an efficient financial management programme was essential. The criteria established by the original ISO 9001 compliant QMS were appraised against the additional requirements of ISO 14001 and a suitable superstructure derived for generation and implementation of an inclusive EMS. The transitional integration of this system was planned so as to produce a QMS suitable to quality, environmental and other management related issues for application to the unique function of a nuclear research reactor. (author)

  5. Sertifikatõ ISO - mafioznaja struktura so znakom pljuss / Olesja Bõkova

    Index Scriptorium Estoniae

    Bõkova, Olesja

    2005-01-01

    Esimesed ISO sertifikaadid, mille aluseks on briti kvaliteedi standardite süsteem, anti Euroopa Liidus välja 1987. a. ISO sertifikaadid Eestis. Diagramm: Välja antud ISO 9000 sertifikaadid 1994-2004

  6. Metrological management evaluation based on ISO10012: an empirical study in ISO-14001-certified Spanish companies

    International Nuclear Information System (INIS)

    Beltran, Jaime; Rivas, Miguel; Munuzuri, Jesus; Gonzalez, Cristina

    2010-01-01

    Environmental management systems based on the ISO 14001 standard rely strongly on metrological measurement and confirmation processes to certify the extent to which organizations monitor and improve their environmental behavior. Nevertheless, the literature lacks in studies that assess the influence of these metrological processes on the performance of environmental management in organizations, even now that the international standard ISO 10012 is already available to establish requisites and guidelines for the development of a metrological management system that is compatible with any other standardized management system. This work seeks to assess that influence through the development of an evaluation model for metrological management, which is then validated through an experimental analysis of the results obtained from the application of an audit process in 11 Spanish companies, all ISO-14001-certified and operating in different industrial sectors. (author)

  7. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  8. Significance of ISO 9000 Quality Management System for ...

    African Journals Online (AJOL)

    Significance of ISO 9000 Quality Management System for Performance ... of ISO 9000 Quality Management System implementation for performance improvement. ... to find out the relationship between certification and process variability.

  9. Neuroprotective effects of α-iso-cubebenol on glutamate-induced neurotoxicity.

    Science.gov (United States)

    Park, Sun Young; Choi, Yung Hyun; Park, Geuntae; Choi, Young-Whan

    2015-09-01

    α-Iso-cubebenol is a natural compound isolated from Schisandra chinensis, and is reported to have beneficial bioactivity including anti-inflammatory and anti-tumor activities. Glutamate-induced oxidative neuronal damage has been implicated in a variety of neurodegenerative disorders. Here we investigated the mechanisms of α-iso-cubebenol protection of mouse hippocampus-derived neuronal cells (HT22 cells) from apoptotic cell death induced by the major excitatory neurotransmitter, glutamate. Pretreatment with α-iso-cubebenol markedly attenuated glutamate-induced loss of cell viability and release of lactate dehydrogenase), in a dose-dependent manner. α-Iso-cubebenol significantly reduced glutamate-induced intracellular reactive oxygen species and calcium accumulation. Strikingly, α-iso-cubebenol inhibited glutamate-induced mitochondrial depolarization, which releases apoptosis-inducing factor from mitochondria. α-Iso-cubebenol also suppressed glutamate-induced phosphorylation of extracellular-signal-regulated kinases. Furthermore, α-iso-cubebenol induced CREB phosphorylation and Nrf-2 nuclear accumulation and increased the promoter activity of ARE and CREB in HT22 cells. α-Iso-cubebenol also upregulated the expression of phase-II detoxifying/antioxidant enzymes such as HO-1 and NQO1. Subsequent studies revealed that the inhibitory effects of α-iso-cubebenol on glutamate-induced apoptosis were abolished by small interfering RNA-mediated knockdown of CREB and Nrf-2. These findings suggest that α-iso-cubebenol prevents excitotoxin-induced oxidative damage to neurons by inhibiting apoptotic cell death, and might be a potential preventive or therapeutic agent for neurodegenerative disorders. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  11. SISTEM HACCP KE DALAM SISTEM MANAJEMEN KEAMANAN PANGAN ISO 22000:2009 (STUDI KASUS DI PT INDOKOM SAMUDRA PERSADA [The Merger of Quality Assurance System ISO 9001:2008 and HACCP system into Food Safety Management SystemISO 22000:2009 (Case Study at Indoko

    Directory of Open Access Journals (Sweden)

    Novri Ilmiawan

    2014-12-01

    Full Text Available The object of this research was to merge the application of HACCP system and ISO 9001:2008 in ISP company into ISO 22000:2009. The  research method used was case study method. The study was conducted on three stages. The first was the arrangement gap analysis conducted by comparing the conditions of the company with ISO 22000:2009 standards. The second was by observing sanitation and pre requisite programs. The third was by observing traceability system. The data in this research were reported descriptively, consisted of ISO 9001:2008 and HACCP application in the company and the gaps of principles in ISO 22000:2009 toward ISO 9001:2008 and HACCP. The result showed that ISP company has applied 12 steps which covered in HACCP system, and also the ISO 9001 system were appropriate with ISO 9001:2008 standards in every clauses. Pre requisite program (GMP and SSOP have been effectively applied. GMP in ISP company is categorized on the first spot (excellent. The eight keys of SSOP have been fulfilled. ISP company has been fulfilling 54 from 57 (94.74% criteria in ISO 22000:2009 standards, yet there still several things needed to be improved, which are the quality manual content  and HACCP table plan and its monitoring. The  traceability system has been applied well in ISP .   Key words : HACCP, ISO 9001, ISO 22000, GMP, SSOP.

  12. Use of a valve operation test and evaluation system to enhance valve reliability

    International Nuclear Information System (INIS)

    Lowry, D.A.

    1990-01-01

    Power plant owners have emphasized the need for assuring safe, reliable operation of valves. While most valves must simply open or close, the mechanisms involved can be quite complex. Motor operated valves (MOVs) must be properly adjusted to assure operability. Individual operator components determine the performance of the entire MOV. Failure in MOVs could cripple or shut down a unit. Thus, a complete valve program consisting of design reviews, operational testing, and preventive and predictive maintenance activities will enhance an owner's confidence level that his valves win operate as expected. Liberty's Valve Operation Test and Evaluation System (VOTES) accurately measures stein thrust without intruding on valve operation. Since mounting a strain gage to a valve stem is a desirable but impractical way of obtaining precise stem thrust, Liberty developed a method to obtain identical data by placing a strain gage sensor on the valve yoke. VOTES provides information which effectively eliminates costly, unscheduled downtime. This paper presents the results of infield VOTES testing. The system's proven ability to identify and characterize actuator and valve performance is demonstrated. Specific topics of discussion include the ability of VOTES to ease a utility's IE Bulletin 8543 concerns and conclusively diagnose MOV components. Data from static and differential pressure testing are presented. Technical, operational, and financial advantages resulting from VOTES technology are explored in detail

  13. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  14. [Accreditation of clinical laboratories based on ISO standards].

    Science.gov (United States)

    Kawai, Tadashi

    2004-11-01

    International Organization for Standardization (ISO) have published two international standards (IS) to be used for accreditation of clinical laboratories; ISO/IEC 17025:1999 and ISO 15189:2003. Any laboratory accreditation body must satisfy the requirements stated in ISO/IEC Guide 58. In order to maintain the quality of the laboratory accreditation bodies worldwide, the International Laboratory Accreditation Cooperation (ILAC) has established the mutual recognition arrangement (MRA). In Japan, the International Accreditation Japan (IAJapan) and the Japan Accreditation Board for Conformity Assessment (JAB) are the members of the ILAC/MRA group. In 2003, the Japanese Committee for Clinical Laboratory Standards (JCCLS) and the JAB have established the Development Committee of Clinical Laboratory Accreditation Program (CLAP), in order to establish the CLAP, probably starting in 2005.

  15. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  16. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  17. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  18. Environmental Management System ISO 14001

    CERN Document Server

    Haider, Syed

    2010-01-01

    This is a must-have tool for any company in the process of adopting and incorporating the ISO 14001:2004 requirements, this book and accompanying CD-ROM provides the latest updates and amendments and translates the ISO language into actionable strategy. Offering administrative solutions to managers of all sorts, it includes practical examples of policies with objectives, targets, and action plans applicable to any process related industry or an ordinary organization. With template formats and hands-on flow charts to describe step-by-step system development, documentation, and implementation ph

  19. Intro to Valve Guide Reconditioning. Automotive Mechanics. Valves. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Horner, W.

    This instructional package, one in a series of individualized instructional units on tools and techniques for repairing worn valve guides in motor vehicles, provides practical experience for students in working on cylinder heads. Covered in the module are reaming valve guides that are oversized to match a new oversized valve, reaming valve guides…

  20. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  1. Synthesis and Biological Activity of 2',3'-iso-Aryl-abscisic Acid Analogs.

    Science.gov (United States)

    Wan, Chuan; Wang, Mingan; Yang, Dongyan; Han, Xiaoqiang; Che, Chuanliang; Ding, Shanshan; Xiao, Yumei; Qin, Zhaohai

    2017-12-15

    2',3'- iso -Benzoabscisic acid ( iso -PhABA), an excellent selective abscisic acid (ABA) analog, was developed in our previous work. In order to find its more structure-activity information, some structural modifications were completed in this paper, including the substitution of phenyl ring and replacing the ring with heterocycles. Thus, 16 novel analogs of iso -PhABA were synthesized and screened with three bioassays, Arabidopsis and lettuce seed germination and rice seedling elongation. Some of them, i.e., 2',3'- iso -pyridoabscisic acid ( iso -PyABA) and 2',3'- iso -franoabscisic acid ( iso -FrABA), displayed good bioactivities that closed to iso -PhABA and natural (+)-ABA. Some others, for instance, substituted- iso -PhABA, exhibited certain selectivity to different physiological process when compared to iso -PhABA or (+)-ABA. These analogs not only provided new candidates of ABA-like synthetic plant growth regulators (PGRs) for practical application, but also new potential selective agonist/antagonist for probing the specific function of ABA receptors.

  2. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  3. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

    DEFF Research Database (Denmark)

    Ihlberg, Leo; Nissen, Henrik Hoffmann; Nielsen, Niels Erik

    2013-01-01

    Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience...

  4. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  5. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  6. Effects of valve timing, valve lift and exhaust backpressure on performance and gas exchanging of a two-stroke GDI engine with overhead valves

    International Nuclear Information System (INIS)

    Dalla Nora, Macklini; Lanzanova, Thompson Diórdinis Metzka; Zhao, Hua

    2016-01-01

    Highlights: • Two-stroke operation was achieved in a four-valve direct injection gasoline engine. • Shorter valve opening durations improved torque at lower engine speeds. • The longer the valve opening duration, the lower was the air trapping efficiency. • Higher exhaust backpressure and lower valve lift reduced the compressor work. - Abstract: The current demand for fuel efficient and lightweight powertrains, particularly for application in downsized and hybrid electric vehicles, has renewed the interest in two-stroke engines. In this framework, an overhead four-valve spark-ignition gasoline engine was modified to run in the two-stroke cycle. The scavenging process took place during a long valve overlap period around bottom dead centre at each crankshaft revolution. Boosted intake air was externally supplied at a constant pressure and gasoline was directly injected into the cylinder after valve closure. Intake and exhaust valve timings and lifts were independently varied through an electrohydraulic valve train, so their effects on engine performance and gas exchanging were investigated at 800 rpm and 2000 rpm. Different exhaust backpressures were also evaluated by means of exhaust throttling. Air trapping efficiency, charging efficiency and scavenge ratio were calculated based on air and fuel flow rates, and exhaust oxygen concentration at fuel rich conditions. The results indicated that longer intake and exhaust valve opening durations increased the charge purity and hence torque at higher engine speeds. At lower speeds, although, shorter valve opening durations increased air trapping efficiency and reduced the estimated supercharger power consumption due to lower air short-circuiting. A strong correlation was found between torque and charging efficiency, while air trapping efficiency was more associated to exhaust valve opening duration. The application of exhaust backpressure, as well as lower intake/exhaust valve lifts, made it possible to increase

  7. Information security in accordance with ISO/IEC 27000

    OpenAIRE

    Košćak , Damjan

    2011-01-01

    The diploma assignment discusses Information Technology Security according to standards ISO/IEC 27001 and ISO/IEC 27002. Diploma consists of two parts. In the first part of the diploma a theoretical bases of information security are presented. The second part presents the introduction of ISO/IEC 27001 security standard in the company »X« in wich I performed a practical training. In the closure my diploma work is upgraded with results of my research work and their analysis as well as wit...

  8. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Rajesh Janardhanan

    2016-05-01

    Full Text Available In intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Learning objectives: • Early recognition of a mitral valve aneurysm (MVA is important because it may rupture and produce catastrophic mitral regurgitation (MR in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR. • Real-time 3D-transesophageal echocardiography (RT-3DTEE is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA.

  9. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    Science.gov (United States)

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  10. ISO sertifikaat kuulutab tootja mainet üle maailma / Ain Alvela

    Index Scriptorium Estoniae

    Alvela, Ain, 1967-

    2006-01-01

    Ilmunud ka: Delovõje Vedomosti 12. apr. lk. 24-25. ISO standardi rakendamine tagab toodangu kvaliteedi ja annab firmale usaldusväärsuse. Kommenteerib Ain Noormägi. Vt. samas: ISO 9001; ISO 14 001; Universaalne standard kohandub ettevõtte vajadustega

  11. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  12. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  13. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  14. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    Science.gov (United States)

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  15. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  16. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  17. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  18. Antioxidant mechanisms of iso-6-cassine in suppressing seizures induced by pilocarpine

    Directory of Open Access Journals (Sweden)

    Rivelilson Mendes de Freitas

    2011-06-01

    Full Text Available The aim of this study was to evaluate the in vitro antioxidant effects of 12-[(2R,5R,6R-5-hydroxy-6-methylpiperidin-2-yl]dodecan-2-one (iso-6-cassine; ISO and the anticonvulsant effects of ISO on pilocarpine-induced seizures in rats. Wistar rats were treated with 0.9% saline (i.p., control group, pilocarpine (400 mg/kg, i.p., pilocarpine group, and the association of ISO (1.0 mg/kg, i.p. plus pilocarpine (400 mg/kg, i.p., 30 min after administration of ISO (ISO plus pilocarpine group. After the treatments all groups were observed for 1h. The antioxidant effect of ISO on the pilocarpine model was assessed by determining the activity of glutathione peroxidase (GPx, glutathione-S-transferase (GST and catalase (CAT as well as the levels of reactive species (RS and lipid peroxidation (LP. In vitro, ISO (5 μM reduced RS and LP. ISO (1.0 mg/kg and abolished seizures and death induced by pilocarpine in rats. ISO protected against the increase in the RS and LP levels, GST activity as well as the inhibition of GPx activity caused by pilocarpine. In addition, ISO increased the catalase activity in hippocampus of seized rats. In conclusion, the dta suggest that ISO can present anticonvulsant and antioxidant properties in the pilocarpine model of seizures in rats.

  19. ISO developments in the United States

    International Nuclear Information System (INIS)

    Hogan, William W.

    1998-01-01

    An important feature of the restructuring process in the United States is the creation of independent system operators (ISOs) to coordinate dispatch and access to transmission grids. A number of ISOs have been proposed and are summarized here. Perhaps the greatest challenge is the pricing of transmission to give proper economic signals to market participants, and the locational pricing scheme now operating in the PJM system offers the best hope for efficient pricing. (author)

  20. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)

  1. ISO 9001 in a neonatal intensive care unit (NICU).

    Science.gov (United States)

    Vitner, Gad; Nadir, Erez; Feldman, Michael; Yurman, Shmuel

    2011-01-01

    The aim of this paper is to present the process for approving and certifying a neonatal intensive care unit to ISO 9001 standards. The process started with the department head's decision to improve services quality before deciding to achieve ISO 9001 certification. Department processes were mapped and quality management mechanisms were developed. Process control and performance measurements were defined and implemented to monitor the daily work. A service satisfaction review was conducted to get feedback from families. In total, 28 processes and related work instructions were defined. Process yields showed service improvements. Family satisfaction improved. The paper is based on preparing only one neonatal intensive care unit to the ISO 9001 standard. The case study should act as an incentive for hospital managers aiming to improve service quality based on the ISO 9001 standard. ISO 9001 is becoming a recommended tool to improve clinical service quality.

  2. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    Science.gov (United States)

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p tricuspid valve regurgitation (mean 2.33 vs 1.3, p tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve regurgitation, significant improvement in tricuspid valve function and right ventricular size occurs in the first

  3. Exploratory Research of ISO 14001:2015 Transition among Portuguese Organizations

    Directory of Open Access Journals (Sweden)

    Luis Miguel Fonseca

    2018-03-01

    Full Text Available The purpose of this paper is the assessment of the ISO 14001:2015 transition process among Portuguese ISO 14001 certified organizations, including those that successfully have already achieved ISO 14001:2015 certification. A considerable number of the surveyed companies proceeded with the transition to the ISO 14001:2015 by introducing slight adjustments and were supported by external consultants. Nearly all of the respondent companies (97% intend to transition until 15th September 2018. The highest ranked reported benefit is the “integrated approach with other management sub-systems” with a well-consolidated perception from the surveyed companies. This is aligned with the ISO 14001:2015 goal of improving the compatibility of management standards supported on the Annex SL. “Alignment with business strategy”, “improved top management commitment” and “improved internal and external communication” are also perceived to obtain significant benefits from ISO 14001:2015. The statistical tests carried out (Kruskal–Wallis confirmed that the perception of some achieved ISO 14001:2015 certification benefits is dependent on the size of the organization. Concerning the motivations to proceed with certification, results suggest that there is not a particular company profile that is compelled to certify their EMS based on a specific type of motivation (Internal or External. Due to ISO 14001:2015 novelty, these exploratory results should be subjected to additional research confirmation.

  4. Boiling Patterns of Iso-asymmetric Nuclear Matter

    International Nuclear Information System (INIS)

    Tõke, Jan

    2013-01-01

    Limits of thermodynamic metastability of self-bound neutron-rich nuclear matter are explored within the framework of microcanonical thermodynamics of interacting Fermi Gas model in Thomas-Fermi approximation. It is found that as the excitation energy per nucleon of the system is increased beyond a certain limiting value, the system loses metastability and becomes unstable with respect to joint fluctuations in excitation energy per nucleon and in isospin per nucleon. As a result, part of the system is forced to boil off in a form of iso-rich non-equilibrated vapors. Left behind in such a process, identifiable with distillation, is a more iso-symmetric metastable residue at a temperature characteristic of its residual isospin content. With a progressing increase in the initial excitation energy per nucleon, more neutron-rich matter is boiled off and a more iso-symmetric residue is left behind with progressively increasing characteristic temperature. Eventually, when all excess neutrons are shed, the system boils uniformly with a further supply of excitation energy, leaving behind a smaller and smaller residue at a characteristic boiling-point temperature of iso-symmetric matter.

  5. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    Science.gov (United States)

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of 1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no reoperations for TV insufficiency

  6. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  7. Flow oscillations on the steam control valve in the middle opening condition. Clarification of the effects of valve body and valve seat by steam experiments

    International Nuclear Information System (INIS)

    Morita, Ryo; Inada, Fumio

    2007-01-01

    A steam control valve might cause vibrations of piping when the valve opening is in a middle condition. For rationalization of maintenance and management of the plant, the valve should be improved, but it is difficult to understand flow characteristics in detail by experiment because flow around the valve is complex 3D structure and becomes supersonic (M>1). Therefore, it is necessary to clarify the cause of the vibrations and to develop the countermeasures by CFD (Computational Fluid Dynamics) technology. In previous researches, we clarified a mechanism of the pressure fluctuations in the middle opening condition and suggested the new valve shape (named 'Extended Valve') that can suppress the pressure fluctuations by air experiments and CFD calculations. Then, we also conducted steam experiments and CFD calculations to understand the differences between air and the steam, and found that the pressure fluctuations in the middle opening condition also occurred in the steam tests and the differences between the air and steam were not remarkable. In this report, to clarify the effects of valve and valve seat shape in steam flow condition, we conduct the steam experiments with various valve and seat shape. As a result, we find the change of the valve seat can decrease the amplitude of pressure fluctuations, but can not quite suppress the pressure fluctuations in the middle opening condition. Then, we apply the 'Extended Valve' to clarify the valve shape effect, and find that the extended valve suppresses the pressure fluctuations in the middle opening condition completely and decreases the pressure amplitude drastically. (author)

  8. PRAPI: post-transcriptional regulation analysis pipeline for Iso-Seq.

    Science.gov (United States)

    Gao, Yubang; Wang, Huiyuan; Zhang, Hangxiao; Wang, Yongsheng; Chen, Jinfeng; Gu, Lianfeng

    2018-05-01

    The single-molecule real-time (SMRT) isoform sequencing (Iso-Seq) based on Pacific Bioscience (PacBio) platform has received increasing attention for its ability to explore full-length isoforms. Thus, comprehensive tools for Iso-Seq bioinformatics analysis are extremely useful. Here, we present a one-stop solution for Iso-Seq analysis, called PRAPI to analyze alternative transcription initiation (ATI), alternative splicing (AS), alternative cleavage and polyadenylation (APA), natural antisense transcripts (NAT), and circular RNAs (circRNAs) comprehensively. PRAPI is capable of combining Iso-Seq full-length isoforms with short read data, such as RNA-Seq or polyadenylation site sequencing (PAS-seq) for differential expression analysis of NAT, AS, APA and circRNAs. Furthermore, PRAPI can annotate new genes and correct mis-annotated genes when gene annotation is available. Finally, PRAPI generates high-quality vector graphics to visualize and highlight the Iso-Seq results. The Dockerfile of PRAPI is available at http://www.bioinfor.org/tool/PRAPI. lfgu@fafu.edu.cn.

  9. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  10. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  11. ISO's analysis of Comet Hale-Bopp

    Science.gov (United States)

    1997-03-01

    The European Space Agency's Infrared Space Observatory ISO inspected Comet Hall-Bopp during the spring and autumn of 1996. The need to keep ISO's telescope extremely cold restricts the spacecraft's pointing in relation to the Sun and the Earth and it ruled out observations at other times. The analyses of the 1996 observations are not yet complete, but already they give new insight into the nature of comets. Comet Hale-Bopp is believed to be a large comet with a nucleus up to 40 kilometres wide. It was discovered in July 1995 by two American astronomers working independently, Alan Hale and Thomas Bopp. At that time, the comet was a billion kilometres away from the Sun, but 200 times brighter than Halley's Comet was, when at a comparable distance. Comet Hale-Bopp will make its closest approach to the Earth on 22 March, and its closest approach to the Sun (perihelion) on 1 April 1997. Some scientific results from ISO The discovery of Comet Hale-Bopp occurred before ISO's launch in November 1995. When first observed by ISO in March and April 1996, the comet was still 700 million kilometres from the Sun, and almost as far from the Earth and ISO. With its privileged view of infrared wavebands inaccessible from the Earth's surface, ISO's photometer ISOPHOT discovered that carbon dioxide was an important constituent of the comet's emissions of vapour.ISOPHOT measured the temperature of the dust cloud around Comet Hale-Bopp. In March 1996, when the comet was still more than 700 million kilometres from the Sun, the dust cloud was at minus 120 degrees C. When ISOPHOT made similar observations in October 1996, the comet was 420 million kilometres from the Sun, and the dust cloud had warmed to about minus 50 degrees C. Intensive observations of Comet Hale-Bopp were also made by ISO's Short-Wave Spectrometer SWS, the Long-Wave Spectrometer LWS, and the ISOPHOT spectrometer PHOT-S. Results are due for publication at the end of March. They will give details about the composition

  12. Characterization of a bioprosthetic bicuspid venous valve hemodynamics: implications for mechanism of valve dynamics.

    Science.gov (United States)

    Tien, W-H; Chen, H Y; Berwick, Z C; Krieger, J; Chambers, S; Dabiri, D; Kassab, G S

    2014-10-01

    Chronic venous insufficiency (CVI) of the lower extremities is a common clinical problem. Although bioprosthetic valves have been proposed to treat severe reflux, clinical success has been limited due to thrombosis and neointima overgrowth of the leaflets that is, in part, related to the hemodynamics of the valve. A bioprosthetic valve that mimics native valve hemodynamics is essential. A computational model of the prosthetic valve based on realistic geometry and mechanical properties was developed to simulate the interaction of valve structure (fluid-structure interaction, FSI) with the surrounding flow. The simulation results were validated by experiments of a bioprosthetic bicuspid venous valve using particle image velocimetry (PIV) with high spatial and temporal resolution in a pulse duplicator (PD). Flow velocity fields surrounding the valve leaflets were calculated from PIV measurements and comparisons to the FSI simulation results were made. Both the spatial and temporal results of the simulations and experiments were in agreement. The FSI prediction of the transition point from equilibrium phase to valve-closing phase had a 7% delay compared to the PD measurements, while the PIV measurements matched the PD exactly. FSI predictions of reversed flow were within 10% compared to PD measurements. Stagnation or stasis regions were observed in both simulations and experiments. The pressure differential across the valve and associated forces on the leaflets from simulations showed the valve mechanism to be pressure driven. The flow velocity simulations were highly consistent with the experimental results. The FSI simulation and force analysis showed that the valve closure mechanism is pressure driven under the test conditions. FSI simulation and PIV measurements demonstrated that the flow behind the leaflet was mostly stagnant and a potential source for thrombosis. The validated FSI simulations should enable future valve design optimizations that are needed for

  13. CNEN, IAEA and ISO normative requirements for measurement management

    International Nuclear Information System (INIS)

    Kibrit, Eduardo

    2009-01-01

    International standard ISO 10012:2003 establishes requirements for measurement management systems, including requirements for measurement processes and measuring equipment. ISO 9001:2008 presents requirements for quality management systems, including requirements for the control of monitoring and measuring equipment. ISO 17025:2005 presents general requirements for the competence of testing and calibration laboratories. In the nuclear field the requirements for measurement management are established by standards published by the International Atomic Energy Agency (IAEA), and in Brazil, by the National Nuclear Energy Commission (CNEN). The present paper presents and discusses the normative requirements for measurement management, considering requirements established by National Nuclear Energy Commission (CNEN), International Atomic Energy Agency (IAEA), and International Organisation for Standardisation (ISO). (author)

  14. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  15. Secondary motion in three-dimensional branching networks

    Science.gov (United States)

    Guha, Abhijit; Pradhan, Kaustav

    2017-06-01

    A major aim of the present work is to understand and thoroughly document the generation, the three-dimensional distribution, and the evolution of the secondary motion as the fluid progresses downstream through a branched network. Six generations (G0-G5) of branches (involving 63 straight portions and 31 bifurcation modules) are computed in one go; such computational challenges are rarely taken in the literature. More than 30 × 106 computational elements are employed for high precision of computed results and fine quality of the flow visualization diagrams. The study of co-planar vis-à-vis non-planar space-filling configurations establishes a quantitative evaluation of the dependence of the fluid dynamics on the three-dimensional arrangement of the same individual branches. As compared to the secondary motion in a simple curved pipe, three distinctive features, viz., the change of shape and size of the flow-cross-section, the division of non-uniform primary flow in a bifurcation module, and repeated switchover from clockwise to anticlockwise curvature and vice versa in the flow path, make the present situation more complex. It is shown that the straight portions in the network, in general, attenuate the secondary motion, while the three-dimensionally complex bifurcation modules generate secondary motion and may alter the number, arrangement, and structure of vortices. A comprehensive picture of the evolution of quantitative flow visualizations of the secondary motion is achieved by constructing contours of secondary velocity | v → S | , streamwise vorticity ω S , and λ 2 iso-surfaces. It is demonstrated, for example, that for in-plane configuration, the vortices on any plane appear in pair (i.e., for each clockwise rotating vortex, there is an otherwise identical anticlockwise vortex), whereas the vortices on a plane for the out-of-plane configuration may be dissimilar, and there may even be an odd number of vortices. We have formulated three new parameters

  16. Small valve area index: its influence on early mortality after mitral valve replacement

    NARCIS (Netherlands)

    Yazdanbakhsh, A. P.; van den Brink, R. B.; Dekker, Egbert; de Mol, B. A.

    2000-01-01

    OBJECTIVE: To test the hypothesis that mitral valve prosthesis-patient mismatch increases postoperative mortality. METHODS AND RESULTS: The effect of mitral valve prosthesis-patient mismatch on survival in a cohort of consecutive patients after mitral valve replacement with a mechanical prosthesis

  17. Die bestuur en opleiding van SABS ISO 9000 reeks

    OpenAIRE

    2014-01-01

    With the lifting of sanctions, South African businesses are faced with a new challenge to compete against their international counterparts on the international and domestic markets. Competing on the international markets is dependant on conforming to a recognised quality management system standard such as ISO 9000 (ISO International Standards Organisation). The South African equivalent for this standard is SABS ISO 9000. (SABS - South African Bureau of Standards). It is thus important for Sou...

  18. Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    Science.gov (United States)

    van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M

    2004-03-01

    To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004

  19. Application of ISO 9001:2000 in a Nuclear Medicine Department

    International Nuclear Information System (INIS)

    Rayo, J.I.; Serrano, J.; Martin, R.; Corral, C.

    2002-01-01

    Since 1947 ISO has been developing voluntary technical standards over almost all sectors of business, industry, and technology. The ISO 9000 standards were published in 1987, and new versions of the standards saw daylight in 1994 and 2000. The highlights of ISO 9001:2000 are: quality management system, management responsibility, resource management, product realization and measurement, analysis and improvement. Aim: Application of ISO 9001:2000 to a Nuclear Medicine Department for provides the organization with a model to follow, customer focus, people will understand the goals of the organization and are motivated to work for objectives and lower costs and shorter cycle times through effective use of resources. Conclusion: ISO 9001:2000 focuses on continual improvement of business processes that should be a permanent objective of the Nuclear Medicine Department

  20. Gloss uniformity measurement update for ISO/IEC 19751

    Science.gov (United States)

    Ng, Yee S.; Cui, Chengwu; Kuo, Chunghui; Maggard, Eric; Mashtare, Dale; Morris, Peter

    2005-01-01

    To address the standardization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standardization committee for office equipment chartered the W1.1 project with the responsibility of drafting a proposal for an international standard for the evaluation of printed image quality1. An ISO draft Standard2, ISO/WD 19751-1, Office Equipment - Appearance-based image quality standards for printers - Part 1: Overview, Procedure and Common Methods, 2004 describes the overview of this multi-part appearance-based image quality standard. One of the ISO 19751 multi-part Standard"s tasks is to address the appearance-based gloss and gloss uniformity issues (in ISO 19751-2). This paper summarizes the current status and technical progress since the last two updates3, 4. In particular, we will be discussion our attempt to include 75 degree gloss (G75) objective measurement5 in differential gloss and within-page gloss uniformity. The result for a round-robin experiment involving objective measurement of differential gloss using G60 and G75 gloss measurement geometry is described. The results for two perceptual-based round-robin experiments relating to haze effect on the perception of gloss, and gloss artifacts (gloss streaks/bands, gloss graininess/mottle) are discussed.

  1. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  2. The Relationship between the Training Function and ISO-9000 Registration.

    Science.gov (United States)

    Maxwell, Randy C.; Jost, Karen L.

    ISO 9000 is one of a series of international standards providing guidelines and governing quality of products and services. The ISO 9000 certification demonstrates the capability of a supplier to control the processes that determine the acceptability of the product or service being supplied. This paper focuses on the training aspects of ISO 9000…

  3. Idiopathic mitral valve prolapse with tricuspid, aortic and pulmonary valve involvement: An autopsy case report

    Directory of Open Access Journals (Sweden)

    Heena M Desai

    2015-01-01

    Full Text Available Mitral valve prolapse (MVP is usually asymptomatic, but can be associated with complications such as infective endocarditis, mitral regurgitation, thromboembolism and sudden cardiac death. It has been very rarely reported to occur in association with other valvular involvement. A 55-year-old male patient was brought dead and at autopsy the mitral valve orifice was stenotic and the leaflets were enlarged, myxoid and bulging suggestive of MVP and chordae tendinae were thickened, stretched and elongated. Similar changes were seen in the tricuspid valve. The pulmonary and aortic valves also showed myxomatous degeneration of their cusps. Myxomatous degeneration is the most common cause of MVP and it can be associated with involvement of the other valves. Concomitant involvement of the aortic valve has been reported, however it is very rare and simultaneous involvement of the pulmonary valve has not been reported in the literature so far. We report a case of MVP associated with myxomatous degeneration of the tricuspid, pulmonary and aortic valves.

  4. API and ISO standards can be combined

    International Nuclear Information System (INIS)

    Weightman, R.T.; Warnack, M.F.

    1992-01-01

    This paper reports that oil field equipment and product manufacturers can maintain a competitive advantage and minimize costs by integrating American Petroleum Institute (API) licensing programs with International Standards Organization (ISO) 9001 standards under one quality system. A combined quality system approach can position a company for quality system certification under ISO 9001 while maintaining API specifications. Furthermore, only one quality system manual is needed for API licensing and ISO certification, avoiding duplication of effort. The benefits of a documented quality program include the flowing: Job descriptions and personnel qualification requirements are documented; The improved documentation allows direct tracing of specific production activities; Laboratory test methods and calibration of test equipment follow accepted standards for more reliable and reproducible test data; Quality control becomes proactive, not reactive, through internal process controls previously not implemented; Employee attitudes improve through appreciation for the overall goals of the company; Ambiguous quality issues, such as documenting special customer requirements, are easily resolved; and The company image improves with customers, particularly for those that require API Specification Q1 or ISO 9001 compliance or those having their own quality performance standards

  5. Valve for closing a steam line

    International Nuclear Information System (INIS)

    Meyer, W.; Potrykus, G.

    1976-01-01

    Instead of several control elements, the quick-closing valve, especially in the main-steam line between steam generator and turbine of a power station has the valve cone itself as the only movable part, acting with its inner surface as a piston within a second cylinder space. The valve shaft is at the same time a piston rod with a stepped piston at the upper end. This piston is loaded in a cylinder at the upspace below the valve cover on one hand by a spring, on the other hand by its own medium. Two non-return valves, one of it in a bore of the valve cone, connect the first-mentioned cylinder space with the steam-loaded inlet resp. outlet side of the valve. For controlling the valve, a magnet valve is sufficient. By automatic control of the valve cone coupled with several pistons several control lines can be omitted. There are also no pressurized control lines outside the valve which could be damaged by exterior influences. (ERA) [de

  6. Experience with ISO quality control in assisted reproductive technology.

    Science.gov (United States)

    Alper, Michael M

    2013-12-01

    Assisted reproductive technology (ART) programs are complex organizations requiring the integration of multiple disciplines. ISO 9001:2008 is a quality management system that is readily adaptable to an ART program. The value that ISO brings to the entire organization includes control of documents, clear delineation of responsibilities of staff members, documentation of the numerous processes and procedures, improvement in tracking and reducing errors, and overall better control of systems. A quality ART program sets quality objectives and monitors their progress. ISO provides a sense of transparency within the organization and clearer understanding of how service is provided to patients. Most importantly, ISO provides the framework to allow for continual improvement. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  7. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. From the box press a valve plate is suspended by four linkage bars, one for each corner. Each linkage bar is provided with two wheels which are respectively mounted at the connections with the box press and the valve plate. The wheels are carried on the horizontal grooves formed in a door valve casing. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing while the valve plate does not contact the casing. When the box press reaches the home position, the wheels drop into the recesses which are disposed at the ends of the grooves, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not over other parts. (Yamaguchi, T.)

  8. Impact of bicuspid aortic valve on complications and death in infective endocarditis of native aortic valves.

    Science.gov (United States)

    Kahveci, Gokhan; Bayrak, Fatih; Pala, Selcuk; Mutlu, Bulent

    2009-01-01

    We retrospectively investigated the impact of bicuspid aortic valve on the prognosis of patients who had definite infective endocarditis of the native aortic valve.Of 51 patients, a bicuspid aortic valve was present in 22 (43%); the other 29 had tricuspid aortic valves. On average, the patients who had bicuspid valves were younger than those who had tricuspid valves. Patients with a tricuspid valve had larger left atrial diameters and were more likely to have severe mitral regurgitation.Periannular complications, which we detected in 19 patients (37%), were much more common in the patients who had a bicuspid valve (64% vs 17%, P = 0.001). The presence of a bicuspid valve was the only significant independent predictor of periannular complications. The in-hospital mortality rate in the bicuspid group was lower than that in the tricuspid group; however, this figure did not reach statistical significance (9% vs 24%, P = 0.15). In multivariate analysis, left atrial diameter was the only independent predictor associated with an increased risk of death (hazard ratio, 2.19; 95% confidence interval, 1.1-4.5; P = 0.031).In our study, patients with infective endocarditis in a bicuspid aortic valve were younger and had a higher incidence of periannular complications. Although a worse prognosis has been reported previously, we found that infective endocarditis in a native bicuspid aortic valve is not likely to increase the risk of death in comparison with infective endocarditis in native tricuspid aortic valves.

  9. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  10. Mitral Valve Prolapse

    Science.gov (United States)

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  11. Application of ceramics to the sliding seat of valve bridge; Valve bridge yodobu eno ceramics tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, T; Ono, T [Mitsubishi Motors Corp., Tokyo (Japan)

    1997-10-01

    For use in the valve train, using an OHV (over head valve) configuration. of a 4 valve diesel engine for trucks and buses; we developed a valve bridge, a component of a valve train, with a ceramic head that is made of silicon nitride(Si3N4) in contact with a rocker arm in order to reduce cost and improve wear resistance for further diesel engine emissions regulations. In order to evaluate the effect of this valve bridge, RIG tests and durability tests on actual engines were carried out. 7 figs., 2 tabs.

  12. Transcatheter Mitral Valve-in-Ring Implantation

    LENUS (Irish Health Repository)

    Tanner, RE

    2018-05-01

    Failed surgical mitral valve repair using an annuloplasty ring has traditionally been treated with surgical valve replacement or repair1. For patients at high risk for repeat open heart surgery, placement of a trans-catheter aortic valve (i.e., TAVI valve) within the mitral ring (i.e., Mitral-Valve-in-Ring, MViR) has emerged as a novel alternative treatment strategy2-5 . We describe our experience of a failed mitral valve repair that was successfully treated with a TAVI valve delivered via the trans-septal approach, and summarise the data relating to this emerging treatment strategy.

  13. A new one-step procedure for pulmonary valve implantation of the melody valve: Simultaneous prestenting and valve implantation.

    Science.gov (United States)

    Boudjemline, Younes

    2018-01-01

    To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.

  14. On the composition of ISO 25964 hierarchical relations (BTG, BTP, BTI)

    NARCIS (Netherlands)

    Alexiev, A; Isaac, A.H.J.C.A.; Lindenthal, J

    2015-01-01

    Knowledge organization systems (KOS) can use different types of hierarchical relations: broader generic (BTG), broader partitive (BTP), and broader instantial (BTI). The latest ISO standard on thesauri (ISO 25964) has formalized these relations in a corresponding OWL ontology (De Smedt et al., ISO

  15. Space Vehicle Valve System

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  16. ISO 14000 information platform. Quarterly report, January 1--March 31, 1998

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    GETE, through its ISO 14000 Information Platform, globeNet{trademark} (www.iso14000.net), seeks to provide FETC and the US Department of Energy (DOE) with a timely, accurate, and reliable information resource on the issue of environmental management standards. This resource allows FETC to keep track of the latest developments in the ISO 14000 arena, in DOE as well as throughout the federal complex and industry. Utilizing this information, FETC and DOE can make critical decisions on their own use and implementation of the ISO 14000 standards. The information platform also provides FETC with a forum to present information on its activities, such as the DOE ISO 14000 Pilot Projects, and as an information gathering and dissemination resource for its publications. GETE works with an array of national and international contacts and content sources to gather information and provide daily updates on ISO 14000 and related environmental management issues.

  17. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  18. Thermally induced pressure locking of gate valves: A survey of valve bonnet pressurization rates

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Moore, W.E.

    1996-01-01

    Closed, water filled gate valves run the risk of becoming pressurized due to heat input from the environment or from adjacent connected piping. Thermal pressurization of gate valve bonnets may lead to the valves failing to open on demand and can even induce structural failure of valves. This paper presents an analytical prediction of the pressurization rate of a closed pressure vessel subject to uniform heating which may be considered as an upper bound to the pressurization rate that may occur in the field. Then actual valve experiences described in the literature are reviewed to determine the expected pressurization rate in existing hardware designs. A statistical approach is applied to reconcile the differing pressurization rates reported in the literature and determine a rate that can be applied in valve evaluations. The limitations of the reconciled rate are discussed

  19. Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

    Science.gov (United States)

    Dager, Antonio E; Nuis, Rutger-Jan; Caicedo, Bernardo; Fonseca, Jaime A; Arana, Camilo; Cruz, Lidsa; Benitez, Luis M; Nader, Carlos A; Duenas, Eduardo; de Marchena, Eduardo J; O'Neill, William W; de Jaegere, Peter P

    2012-01-01

    At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.

  20. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  1. ISO 9001 certification for hospitals in Bulgaria: does it help service?

    Science.gov (United States)

    Stoimenova, Assena; Stoilova, Ani; Petrova, Guenka

    2014-03-04

    The aim of our study is to review the published literature on establishment and implementation of ISO 9001 QMS in European hospitals, to study the availability of International Organization for Standardization (ISO) quality management systems (QMS) in Bulgarian hospitals and to outline the main advantages of ISO implementation in the hospitals in Bulgaria. The information on availability of ISO QMS in the hospitals in Bulgaria was gathered via Bulgarian certification register, the registries of various quality associations, websites of hospitals and certification companies presented in Bulgaria. A total number of 312 hospitals in Bulgaria were screened for the availability of QMS certified against the ISO 9001 requirements. The experience of European hospitals that implemented QMS is positive and the used approaches to improve the processes and the demonstrated effects from ISO implementation are analysed by the researchers. Unlike other European Union member states, the establishment of quality management systems in Bulgaria is not compulsory. However, our study revealed that 14.42% of the hospitals in Bulgaria have implemented and have certified quality systems against the requirements of ISO 9001. Our study confirmed that a quality management system using the ISO 9001 standard is useful for the hospitals as it can help to increase the operational efficiencies, to reduce errors, improve patient safety and produce a more preventive approach instead of a reactive environment.

  2. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model.

    Science.gov (United States)

    He, Z; Xi, B; Zhu, K; Hwang, N H

    2001-09-01

    The induction of mechanical heart valve (MHV) cavitation was investigated using a 27 mm Medtronic Hall (MH27) tilting disk valve. The MH27 valve was mounted in the mitral position of a simulating pulse flow system, and stroboscopic lighting used to visualize cavitation bubbles on the occluder inflow surface at the instant of valve closure. MHV cavitation was monitored using a digital camera with 0.04 mm/pixel resolution sufficient to render the tiny bubbles clearly visible on the computer monitor screen. Cavitation on MH27 valve was classified as five types according to the time, site and shape of the cavitation bubbles. Valve cavitation occurred at the instant of occluder impact with the valve seat at closing. The impact motion was subdivided into three temporal phases: (i) squeezing flow; (ii) elastic collision; and (iii) leaflet rebound. MHV cavitation caused by vortices was found to be initiated by the squeezing jet and/or by the transvalvular leakage jets. By using a tension wave which swept across the occluder surface immediately upon elastic impact, nuclei in the vortex core were expanded to form cavitation bubbles. Analysis of the shape and location of the cavitation bubbles permitted a better understanding of MHV cavitation mechanisms, based on the fluid dynamics of jet vortex and tension wave propagations.

  3. Inter ISO Market Coordination by Calculating Border Locational Marginal Prices

    Directory of Open Access Journals (Sweden)

    BABIC, A. B.

    2013-05-01

    Full Text Available In this paper the methodology for solving Locational Marginal Price (LMP differences (inconsistency of LMPs that arise at the boundary buses between separate power markets is proposed. The algorithm developed enables us to obtain consistent LMP values at the boundary buses between interconnected ISOs. A Primal-Dual Interior Point based optimal power flow (OPF is applied, with complete set of power system physical limit constraints, to solve a regional spot market. The OPF is implemented such that producer and consumer behaviors are modeled simultaneously, while the welfare is maximized. In this paper a generalized methodology for multiple ISOs case is proposed and later it is practically applied on two interconnected independent entities. The algorithm for approximation of cost coefficients of generators and dispatchable loads for neighboring ISOs is proposed. The developed algorithm enables participating ISOs to obtain LMPs at the boundary buses with other interconnected ISOs. By controlling interchange of electric power at the scheduled level, regional spot markets are resolved eliminating possible exercise of market power by individual interconnected ISOs. Results of proposed methodology are tested on the IEEE 118-bus power system.

  4. Fairchild Stratos Division's Type II prototype lockhopper valve: METC Prototype Test Valve No. F-1 prototype lockhopper valve-testing and development project. Static test report

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D. R.; Cutright, R. L.; Griffith, R. A.; Loomis, R. B.; Maxfield, D. A.; Moritz, R. S.

    1981-10-01

    METC Prototype Test Valve No. F-1 is a hybrid design, based on a segmented ball termed a visor valve, developed and manufactured by Fairchild Stratos Division under contract to the Department of Energy. The valve uses a visor arm that rotates into position and then translates to seal. This valve conditionally completed static testing at METC with clean gas to pressures of 1600 psig and internal valve temperatures to 600/sup 0/F. External leakage was excessive due to leakage through the stuffing box, purge fittings, external bolts, and other assemblies. The stuffing box was repacked several times and redesigned midway through the testing, but external leakage was still excessive. Internal leakage through the seats, except for a few anomalies, was very low throughout the 2409 cycles of testing. As shown by the low internal leakage, the visor valve concept appears to have potential for lock-hopper valve applications. The problems that are present with METC Prototype Test Valve No. F-1 are in the seals, which are equivalent to the shaft and bonnet seals in standard valve designs. The operating conditions at these seals are well within the capabilities of available seal designs and materials. Further engineering and minor modifications should be able to resolve the problems identified during static testing.

  5. Short- and long-term need for permanent pacemaker after transcatheter implantation of the Edwards Sapien aortic valve prosthesis.

    Science.gov (United States)

    Moreno, Raúl; Calvo, Luis; Sánchez-Recalde, Angel; Galeote, Guillermo; Jiménez-Valero, Santiago; López, Teresa; Plaza, Ignacio; González-Davia, Rosa; Ramírez, Ulises; Mesa, Jose Maria; Moreno-Gomez, Isidro; López-Sendón, José-Luis

    2015-11-01

    A permanent pacemaker is frequently needed after transcatheter aortic valve implantation, but the available data are mainly on the CoreValve system. To evaluate the need for new permanent pacemaker after implantation of the Edwards Sapien device, as well as related factors. We included the first 100 patients treated with the Edwards Sapien device at our institution. Of these, 12 had a permanent pacemaker before the procedure, and thus our study population was the remaining 88 patients. A permanent pacemaker was indicated in eight patients (9.1%) during hospitalization or at 30 days. After discharge, another four patients needed a pacemaker (at 42 days and three, 18, and 30 months). Two variables were associated with the need for pacemaker during hospitalization: previous dialysis (13% vs. 1%, p=0.042) and complete right bundle branch block before the procedure (25% vs. 5%, p=0.032). More than one month after the procedure, the characteristics associated with the need for pacemaker were plasma creatinine level (2.5±1.7 vs. 1.3±0.6 mg/dl, p=0.001) and previous myocardial infarction (50% vs. 10%, p=0.013). The rate of pacemaker implantation with the Edwards Sapien device was 9.1%. Right bundle branch block and dialysis were associated with this complication.

  6. Design And Analysis Of A Camless Valve Mechanism For I.C Engines Using Rotary Disc Valves

    Directory of Open Access Journals (Sweden)

    Vivek Jitendra Panchal

    2017-09-01

    Full Text Available It is the object of the presented paper to provide an electromechanical rotary valve actuating system for opening and closing valves of an internal combustion engine capable of separately controlling both the inlet and exhaust valve operations of each individual cylinder in a multi-cylinder engine. This indicates that only one valve will be required for each cylinder of the engine. Previously published versions of this concept require a separate valve for intake and exhaust in each cylinder. The system provides an alternative to the camshaft assembly in an attempt to overcome the limitations and inadequacies inevitably posed by a fully mechanical system. The prototype development is approached in a theoretical manner beginning with the conceptualization and design of a rotating disk with a notches and corresponding closure surfaces to open and close the flow path. The actuated disk and notch design is then refined and followed by the design of an inlet and exhaust manifold to correspond to the valve design and the theorizing and design of a sealing gasket. The rotating speed of the valve is determined by a general idling speed and can be varied to provide variable valve timing with the motor. The final assembly eliminates a majority of the moving parts currently used in camshaft systems like the cam camshaft rocker arm push rod and springs and results in a significantly lighter valve actuation system. By eliminating the translatory motion of valves the problem of valves slamming on the valve seats at high velocities is eliminated thus greatly reducing engine wear.

  7. Branching structure and strain hardening of branched metallocene polyethylenes

    International Nuclear Information System (INIS)

    Torres, Enrique; Li, Si-Wan; Costeux, Stéphane; Dealy, John M.

    2015-01-01

    There have been a number of studies of a series of branched metallocene polyethylenes (BMPs) made in a solution, continuous stirred tank reactor (CSTR) polymerization. The materials studied vary in branching level in a systematic way, and the most highly branched members of the series exhibit mild strain hardening. An outstanding question is which types of branched molecules are responsible for strain hardening in extension. This question is explored here by use of polymerization and rheological models along with new data on the extensional flow behavior of the most highly branched members of the set. After reviewing all that is known about the effects of various branching structures in homogeneous polymers and comparing this with the structures predicted to be present in BMPs, it is concluded that in spite of their very low concentration, treelike molecules with branch-on-branch structure provide a large number of deeply buried inner segments that are essential for strain hardening in these polymers

  8. Branching structure and strain hardening of branched metallocene polyethylenes

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Enrique; Li, Si-Wan; Costeux, Stéphane; Dealy, John M., E-mail: john.dealy@mcgill.ca [Department of Chemical Engineering, McGill University, Montreal, Quebec H3A 0C4 (Canada)

    2015-09-15

    There have been a number of studies of a series of branched metallocene polyethylenes (BMPs) made in a solution, continuous stirred tank reactor (CSTR) polymerization. The materials studied vary in branching level in a systematic way, and the most highly branched members of the series exhibit mild strain hardening. An outstanding question is which types of branched molecules are responsible for strain hardening in extension. This question is explored here by use of polymerization and rheological models along with new data on the extensional flow behavior of the most highly branched members of the set. After reviewing all that is known about the effects of various branching structures in homogeneous polymers and comparing this with the structures predicted to be present in BMPs, it is concluded that in spite of their very low concentration, treelike molecules with branch-on-branch structure provide a large number of deeply buried inner segments that are essential for strain hardening in these polymers.

  9. The dark side of ISO 14001: The symbolic environmental behavior

    Directory of Open Access Journals (Sweden)

    Vera Ferrón Vílchez

    2017-01-01

    Full Text Available Some of the academic research on ISO 14001 has focused on analyzing the benefits of its adoption. However, this international standard has also received some criticism, particularly in respect of the adoption of ISO 14001 when not accompanied by significant improvements in environmental performance. This study analyzes the relationship between the symbolic environmental behavior and the adoption of ISO 14001. In so doing, it uses binary logistic regression to analyze an international sample of 1961 manufacturing facilities that each employs more than 50 people. The results indicate that the higher the symbolic environmental performance of the firm, the greater the probability of adopting ISO 14001.

  10. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  11. ISO certification pays off in quality improvement

    International Nuclear Information System (INIS)

    Vermeer, F.J.G.

    1992-01-01

    This paper reports that by obtaining and maintaining International Standards Organization (ISO) 9001 certification, a company can improve its quality control system, cut waste, and motivate its employees. In so doing it improves its competitive position in both international and domestic markets. The success of a number of countries (notably Japan) in the world markets has focused the attention of the industrialized countries on improving quality levels and striving for a unified, worldwide quality standard. This has been particularly true in Europe; with several countries competing in a single market, a common quality standard has been a highly desirable goal for decades. One of the first multinational quality standards evolved in the European Community, which is estimated to become a single market with a gross national product of $4.5 trillion by 1992. As a consequence, in 1987 the International Standards Organization created ISO 9000, a single standard to ensure uniform quality in products and services offered with this growing market. U.S. petroleum and natural gas companies must recognize and implement the ISO 9000 standards or possibly lose international markets. If the present worldwide trend towards ISO 9000 continues (and there is no reason to believe that it will not), the standards will be just as important in the domestic market

  12. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

    Science.gov (United States)

    Ferrari, Enrico; Franciosi, Giorgio; Clivio, Sara; Faletra, Francesco; Moccetti, Marco; Moccetti, Tiziano; Pedrazzini, Giovanni; Demertzis, Stefanos

    2017-03-01

    The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch. Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery. Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery. © The Author 2016. Published by Oxford University Press on behalf of the

  13. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  14. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid insufficiency or tricuspid incompetence. It means there is a ... require valve surgery. Tags: heart valves , tricuspid incompetence , ... tricuspid regurgitation , tricuspid stenosis , valve disease Related Links ...

  16. The impact of ISO 14000 on developing world businesses

    International Nuclear Information System (INIS)

    Mohamed, S.T.

    2001-01-01

    ISO 14000 has attracted interest from industry, international organizations and governments around the globe. Policy-makers and industry both appear to be looking to the standards as a key component of a new paradigm for cooperation between regulators and industry. This realization seems to have resulted from a growing awareness that the fragmented, reactive approach to environmental management in the past has not produced optimal results. Businesses are realizing the value of integrating their compliance procedures for each regulation into a broader system. Compliance problems can often be linked to system problems such as inadequate training, lack of responsibility at the right level, inadequate data, and other related causes. An effective Environmental Management System (EMS) eliminates these pitfalls. The evolution of the EMS is being shaped by market forces, ISO 9000, regulatory shifts, public awareness, and cost implications for ISO certifications. The transformation of these management practices is not limited to industrialized countries. In anticipation of the non-tariff trade barriers that could be erected as a result of these standards, many developing countries are seeking avenues of compliance with ISO 14000's requirements. Egypt should be concerned with the implementation of this system, for firms in countries of the European Community (EC) have been given explicit instructions by the three prevalent European standard-setting organizations to ''familiarize'' themselves with the requirements of ISO 14000. This paper will focus primarily on the expected effects of ISO 14001. (author)

  17. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm).

    Science.gov (United States)

    Kato, Yasuyuki; Hattori, Koji; Motoki, Manabu; Takahashi, Yosuke; Kotani, Shinsuke; Nishimura, Shinsuke; Shibata, Toshihiko

    2013-07-01

    Controversy exists regarding the optimal operative method or type of prosthesis for patients with a small aortic root. The aim of this retrospective study was to investigate the early and mid-term outcomes of standard aortic valve replacement (AVR) using 16 mm or 18 mm ATS Advanced Performance (AP) or 17 mm St. Jude Medical (SJM) Regent valves for a small aortic root. Between April 2003 and August 2009, 78 patients (age range: 50-86 years; 86% aged > or = 65 years) underwent AVR with 16 mm or 18 mm ATS AP valves (16AP group: n = 21, 18AP group: n = 32), or a 17 mm SJM Regent valve (17Regent group: n = 25). Fifty-six patients (72%) had a body surface area (BSA) of regression was similar among the groups (-30%, -25% and -28% in the 16AP, 17Regent and 18AP groups, respectively; p = 0.844). The early and mid-term results of AVR with 16 mm or 18 mm ATS AP valves, or with a 17 mm SJM Regent valve, were satisfactory. Therefore, standard AVR using these small mechanical prostheses, which avoids the need to enlarge the annulus or to conduct stentless bioprosthesis implantation, might represent an acceptable method, especially in elderly patients with a small aortic root.

  18. Iso-α-acids, bitter components of beer, prevent obesity-induced cognitive decline.

    Science.gov (United States)

    Ayabe, Tatsuhiro; Ohya, Rena; Kondo, Keiji; Ano, Yasuhisa

    2018-03-19

    Dementia and cognitive decline have become worldwide public health problems, and it was recently reported that life-style related diseases and obesity are key risk factors in dementia. Iso-α-acids, hop-derived bitter components of beer, have been reported to have various physiological functions via activation of peroxisome proliferator-activated receptor γ. In this report, we demonstrated that daily intake of iso-α-acids suppresses inflammations in the hippocampus and improves cognitive decline induced by high fat diet (HFD). Body weight, epididymal fat weight, and plasma triglyceride levels were increased in HFD-fed mice, and significantly decreased in iso-α-acids supplemented HFD-fed mice. HFD feeding enhances the production of inflammatory cytokines and chemokines, such as TNF-α, which was significantly suppressed by iso-α-acids administration. HFD-induced neuroinflammation caused lipid peroxidation, neuronal loss, and atrophy in hippocampus, and those were not observed in iso-α-acids-treated mice. Furthermore, iso-α-acids intake significantly improved cognitive decline induced by HFD-feeding. Iso-α-acids are food derived components that suppressing both lipid accumulation and brain inflammation, thus iso-α-acids might be beneficial for the risk of dementia increased by obesity and lifestyle-related diseases.

  19. New water and remote galaxies complete ISO's observations

    Science.gov (United States)

    ISO's operational teams at ESA's ground station at Villafranca near Madrid have been hurrying to provide the world's astronomers with as many observations as possible. They have long anticipated the exhaustion of ISO's vital supply of liquid helium, which cooled the infrared telescope and its instruments to their operating temperatures, close to absolute zero. Two weeks after ISO was put into orbit on 17 November 1995 by an Ariane 44P launcher, the external parts of the cooling system had settled to the operating temperature. The specification required that ISO should then operate for at least 18 months -- implying that operations might have to end in May 1997. Thanks to superb engineering by European industry, which built the spacecraft and its super-cool telescope, ISO has given astronomers almost a year longer than that. During the extra time the count of ISO's observations of cosmic objects has risen from 16,000 to about 26,000. Among the benefits of ISO's longevity has been the chance to examine an important region of the sky, in and around the constellation of Orion. This was not accessible in the nominal mission but has now been observed in two periods. Four inter national teams, supported by national funding agencies, supplied the instruments to analyse the infrared rays received by ISO's telescope. The principal investigators leading the teams are Dietrich Lemke (Heidelberg, Germany) for the versatile photometer ISOPHOT, Catherine Cesarsky (Saclay, France) for the camera ISOCAM, Thijs de Graauw (Groningen, the Netherlands) for the Short Wavelength Spectrometer SWS, and Peter Clegg (London, UK) for the Long Wavelength Spectrometer LWS. Water vapour on Titan A big difference between ISO and the only previous infrared astronomy satellite (IRAS 1983) has been its ability to examine individual objects across a wide range of accurately defined infrared wavelengths. Many spectra showing patterns of intensities at the different wavelengths have enabled astronomers

  20. The ISO 50001 Impact Estimator Tool (IET 50001 V1.1.4) - User Guide and Introduction to the ISO 50001 Impacts Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Therkelsen, Peter L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Aghajanzadeh, Arian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McKane, Aimee T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-01

    ISO 50001-Energy management systems – Requirements with guidance for use, is an internationally developed standard that provides organizations with a flexible framework for implementing an energy management system (EnMS) with the goal of continual energy performance improvement. The ISO 50001 standard was first published in 2011 and has since seen growth in the number of certificates issued around the world, primarily in the industrial (agriculture, manufacturing, and mining) and service (commercial) sectors. Policy makers in many regions and countries are looking to or are already using ISO 50001 as a basis for energy efficiency, carbon reduction, and other energy performance improvement schemes. The Impact Estimator Tool 50001 (IET 50001 Tool) is a computational model developed to assist researchers and policy makers determine the potential impact of ISO 50001 implementation in the industrial and service (commercial) sectors for a given region or country. The IET 50001 Tool is based upon a methodology initially developed by the Lawrence Berkeley National Laboratory that has been improved upon and vetted by a group of international researchers. By using a commonly accepted and transparent methodology, users of the IET 50001 Tool can easily and clearly communicate the potential impact of ISO 50001 for a region or country.

  1. ISO Spectroscopy of Proto-Planetary Nebulae

    Science.gov (United States)

    Hrivnak, Bruce J.

    2000-01-01

    The goal of this program was to determine the chemical properties of the dust shells around protoplanetary nebulae (PPNs) through a study of their short-wavelength (6-45 micron) infrared spectra. PPNs are evolved stars in transition from the asymptotic giant branch to the planetary nebula stages. Spectral features in the 10 to 20 gm region indicate the chemical nature (oxygen- or carbon-rich), and the strengths of the features relate to the physical properties of the shells. A few bright carbon-rich PPNs have been observed to show PAH features and an unidentified 21 micron emission feature. We used the Infrared Space Observatory (ISO) to observe a sample of IRAS sources that have the expected properties of PPNs and for which we have accurate positions. Some of these have optical counterparts (proposal SWSPPN01) and some do not (SWSPPN02). We had previously observed these from the ground with near-infrared photometry and, for those with visible counterparts, visible photometry and spectroscopy, which we have combined with these new ISO data in the interpretation of the spectra. We have completed a study of the unidentified emission feature at 21 micron in eight sources. We find the shape of the feature to be the same in all of the sources, with no evidence of any substructure. The ratio of the emission peak to continuum ranges from 0.13 to 1.30. We have completed a study of seven PPNs and two other carbon-rich objects for which we had obtained ISO 2-45 micron observations. The unidentified emission features at 21 and 30 micron were detected in six sources, including four new detections of the 30 micron feature. This previously unresolved 30 micron feature was resolved and found to consist of a broad feature peaking at 27.2 micron (the "30 micron" feature) and a narrower feature peaking at 25.5 micron (the "26 micron" feature). This new 26 micron feature is detected in eight sources and is particularly strong in IRAS Z02229+6208 and 16594-4656. The unidentified

  2. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    Science.gov (United States)

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  3. ISO 50001 and SEP Faster and Cheaper - Exploring the Enterprise-Wide Approach

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jingjing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Therkelsen, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sheaffer, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Scheihing, Paul [USDOE, Washington, DC (United States); Tamm, Yannick [Energetics, Inc. (United States)

    2017-06-01

    ISO 50001 and other management systems (e.g., ISO 9001 and ISO 14001) allow for implementation and certification at the enterprise level. The "Central Office" concept, which allows a small group of employees to manage and facilitate the organization’s energy management system (EnMS) at the enterprise level, was introduced within the ISO 50003 standard to provide guidance to ISO 50001 certification bodies. Four industrial companies have partnered with the United States Department of Energy to pilot the enterprise-wide ISO 50001/SEP concept under the Better Buildings Superior Energy Performance (SEP) Enterprise-wide Accelerator. Each organization developed a Central Office to host their EnMS while implementing ISO 50001/SEP at multiple physically separated sites. The four corporate partners tailored their Central Office implementation model to meet their own specific circumstances and needs. This paper reviews the commonalities, differences, and benefits of each of these enterprise-wide implementation models, including organizational structures, Central Office staff responsibilities, and key strategies. The cost savings and benefits of using the enterprise-wide approach were assessed, including the cost per site compared with that of a conventional, single-site ISO 50001/SEP implementation approach. This paper also discusses the drivers for the cost reductions realized through these enterprise-wide approaches. The four partner companies worked with 30 total sites. On average, these 30 sites improved energy performance by 5% annually over their SEP achievement periods, saved more than $600,000 annually in energy costs and reduced implementation cost for ISO 50001 and SEP by $19,000 and 0.8 Full Time Equivalent × years (FTE-yr) of staff time per site. The results can inform other organizations seeking to implement enterprise-wide ISO 50001/SEP, as well as energy efficiency organizations seeking to promote wider adoption of ISO 50001 implementation.

  4. Implementation of ISO guide 25 in a medical dosimetry secondary standards calibration laboratory

    International Nuclear Information System (INIS)

    DeWerd, L.A.

    1995-01-01

    Currently, there is a great deal of discussion among industry and government agencies about ISO 9000 accreditation. U.S. manufacturers with ISO 9000 accreditation are regarded more favorably by European countries. The principles behind the ISO 9000 accreditation are based on the Total Quality Management (TQM) principles that are being implemented in many U.S. industries. This paper will deal only with the calibration issue. There is a difference in the areas covered by ISO 9000 and ISO Guide 25 documents. ISO 9000, in particular ISO 9001 - ISO 9003, cover the open-quotes calibrationclose quotes of inspection, measuring and test equipment. This equipment is basically used for open-quotes factory calibrationsclose quotes to determine that equipment is performing within manufacturer specifications. ISO Guide 25 is specifically for open-quotes calibration and testing laboratories,close quotes generally laboratories that have painstaking procedures to reduce uncertainties and establish high accuracy of the transfer of calibration. The experience of the University of Wisconsin Accredited Dosimetry Calibration Laboratory in conforming to ISO Guide 25 will be outlined. The entire laboratory staff must become familiar with the process and an individual with direct authority must become the one to maintain the quality of equipment and calibrations in the role of open-quotes quality-assurance manager.close quotes

  5. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  6. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    Science.gov (United States)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  7. Perancangan SMKI Berdasarkan SNI ISO/IEC27001:2013 dan SNI ISO/IEC27005:2013 (Studi Kasus DPTSI-ITS

    Directory of Open Access Journals (Sweden)

    Furqon Mauladani

    2018-03-01

    Full Text Available Institut Teknologi Sepuluh Nopember (ITS adalah salah satu universitas di Surabaya. ITS telah menggunakan TIK untuk keperluan operasional bisnisnya (contohnya isi kartu program studi, proses absensi, pembaharuan informasi, dan lainnya. Penggunaan TIK tidak dapat dipisahkan dari ancaman yang dapat mengganggu operasional TIK. Ancaman terdiri dari ancaman yang berasal dari luar (penyebaran malware, aktifitas social engineering, orang dalam (sengaja, tidak sengaja, kegagalan teknis (kesalahan penggunaan, kegagalan perangkat keras/lunak ataupun bencana alam (kebakaran, gempa, banjir. Metode yang digunakan pada penelitian ini adalah melakukan manajemen resiko keamanan informasi berdasarkan SNI ISO/IEC 27005 dan perancangan dokumen SMKI berdasarkan SNI ISO/IEC 27001. Hasil penelitian ini adalah 60 resiko yang tidak diterima dari total 228 resiko yang telah teridentifikasi. Dari 60 resiko tersebut, terdapat 58 risk modification, 1 risk avoidance, dan 1 risk sharing. Tata kelola keamanan informasi yang dirancang berdasarkan SNI ISO/IEC 27001 adalah ruang lingkup SMKI, kebijakan SMKI, proses penilaian resiko, proses penanganan resiko, statement of applicability, dan sasaran keamanan informasi.

  8. Standardization by ISO to Ensure the Sustainability of Space Activities

    Science.gov (United States)

    Kato, A.; Lazare, B.; Oltrogge, D.; Stokes, H.

    2013-08-01

    The ISO / Technical Committee 20 / Sub-committee 14 develops debris-related standards and technical reports to mitigate debris and help ensure mission and space sustainability. While UN Guidelines and the IADC Guidelines encourage national governments and agencies to promote debris mitigation design and operation, the ISO standards will help the global space industry promote and sustain its space-related business. In this paper the scope and status of each ISO standard is discussed within an overall framework. A comparison with international guidelines is also provided to demonstrate the level of consistency. Finally, as a case study, the ISO standards are applied to a CubeSat mission, thus demonstrating their usability on a relatively recent and popular class of satellite.

  9. Isoe - information system on occupational exposure. Ten years of experience

    International Nuclear Information System (INIS)

    2002-01-01

    The information System on Occupational Exposure (ISOE) was created in 1992 to provide a forum for radiation protection experts from both utilities and national regulatory authorities to discuss, promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The ISOE System is jointly managed by the OECD Nuclear Energy Agency (NEA) and the International Atomic Energy Agency (IAEA). This report provides an overview of the experience gained from, and benefits provided by, the ISOE System over the past ten years. Active participation of a large number of utilities in ISOE has contributed to a reduction in occupational exposure at nuclear power plants worldwide. (authors)

  10. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  11. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  12. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  13. Surge-damping vacuum valve

    International Nuclear Information System (INIS)

    Bullock, J.C.; Kelley, B.E.

    1977-01-01

    A valve for damping out flow surges in a vacuum system is described. The surge-damping mechanism consists of a slotted, spring-loaded disk adjacent to the valve's vacuum port (the flow passage to the vacuum roughing pump). Under flow surge conditions, the differential pressure forces the disk into a sealing engagement with the vacuum port, thereby restricting the gas flow path to narrow slots in the disk's periphery. The increased flow damps out the flow surge. When pressure is equalized on both sides of the valve, the spring load moves the disk away from the port to restore full flow conductance through the valve

  14. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.

    Science.gov (United States)

    Lenders, Guy D; Collas, Valérie; Hernandez, José Maria; Legrand, Victor; Danenberg, Haim D; den Heijer, Peter; Rodrigus, Inez E; Paelinck, Bernard P; Vrints, Christiaan J; Bosmans, Johan M

    2014-10-20

    Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. We aimed to evaluate the implantation depth, the incidence and predictors of new conduction disturbances, and the need for PPM implantation within the first month after TAVI, using the new Accutrak CoreValve delivery system (ACV), compared to the previous generation CoreValve (non-ACV). In 5 experienced TAVI-centers, a total of 120 consecutive non-ACV and 112 consecutive ACV patients were included (n=232). The mean depth of valve implantation (DVI) was 8.4±4.0 mm in the non-ACV group and 7.1±4.0 mm in the ACV group (p=0.034). The combined incidence of new PPM implantation and new LBBB was 71.2% in the non-ACV group compared to 50.5% in the ACV group (p=0.014). DVI (p=0.002), first degree AV block (p=0.018) and RBBB (p<0.001) were independent predictors of PPM implantation. DVI (p<0.001) and pre-existing first degree AV-block (p=0.021) were identified as significant predictors of new LBBB. DVI is an independent predictor of TAVI-related conduction disturbances and can be reduced by using the newer CoreValve Accutrak delivery system, resulting in a significantly lower incidence of new LBBB and new PPM implantation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  16. [Efforts to achieve and effects of acquiring ISO 15189 in Tokushima University Hospital].

    Science.gov (United States)

    Shono, Kazuko; Kishi, Misako; Satou, Mituyo; Nagamine, Yasunori; Doi, Tosio

    2009-12-01

    The medical laboratory of Tokushima University Hospital acquired ISO 15189, an international standard for medical laboratories, on July 6th, 2007, resulting in it achieving the 24th place in Japan and 5th place among national university hospitals. The first surveillance was just performed on October 6th, 2008. Tokushima University Hospital, in which our medical laboratory is included as one section, already succeeded in acquiring ISO 9001, PrivacyMark System, and Quality Health Care ver. 5 before accomplishing ISO 15189. To achieve ISO 15189, we prepared documents based on ISO 9001 without any consultation, resulting in a review of the difference between ISO 9001 and ISO 15189 after the preliminary survey. Although achieving ISO 15189 resulted in an improvement in the reliability of laboratory results and accuracy, leading to the development of our technical skills and awareness, and sharing of knowledge, we consider that the considerable investment of time to prepare the requirements remains to be overcome.

  17. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

    Science.gov (United States)

    Krackhardt, Florian; Kherad, Behrouz; Krisper, Maximilian; Pieske, Burkert; Laule, Michael; Tschöpe, Carsten

    2017-01-01

    Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pacemaker implantation while being safe and successful according to Valve Academic Research Consortium 2 (VARC2)-criteria. A total of 23 patients with symptomatic severe aortic valve stenosis, an aortic annulus of 19-27 mm and at high risk for surgery were treated with the Lotus valve. In all patients the valve was implanted in a high annulus position via femoral access. The primary device performance endpoint was VARC2-defined device success after 30 days and the primary safety endpoint was the need for permanent pacemaker implantation. The mean age was 73.23 ± 7.65 years, 46% were female, 38% were New York Heart Association class III/IV at baseline. Thirty-day follow-up data were available for all patients. The VARC2-defined device success rate after 30 days was 22/23 (96%). 2/21 (10%) patients required a newly implanted pacemaker due to 3rd degree atrioventricular block. 25% of the patients developed a new left bundle branch block after valvuloplasty or device implantation. 21 of the 23 patients (96%) had no other signs of conduction disturbances after 30 days. The approach of the modified implantation technique of Lotus TAVR device was safe and effective. The incidence of need for a permanent pacemaker following TAVR could be significantly reduced due to adopted implantation protocol.

  18. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    Abramson, R.; Elie, X.; Vercasson, M.; Nedelec, J.

    1974-01-01

    Conventionally, valves for sodium pipes smaller than 125 mm in diameter are called ''small sodium valves''. However, this limit should rather be considered as the lower limit o ''large sodium valves''. In fact, both the largest sizes of small valves and the smallest of large valves can be found in the range of 125-300 mm in diameter. Thus what is said about small valves also applies, for a few valve types, above the 125 mm limit. Sodium valves are described here in a general manner, with no manufacturing details except when necessary for understanding valve behavior. Operating experience is pointed out wherever possible. Finally, some information is given about ongoing or proposed development plans. (U.S.)

  19. Griswold Tempered Water Flow Regulator Valves Used as Anti-Siphon Valves

    International Nuclear Information System (INIS)

    MISKA, C.

    2000-01-01

    FCV-1*22 and 1*23 are Griswold constant flow regulators used as anti-siphon valves in the tempered water system, they fail closed but valve cartridge orifice allows minimum flow to prevent loss of water from the MCO/CASK annulus

  20. Effects of aging and service wear on main steam isolation valves and valve operators

    International Nuclear Information System (INIS)

    Clark, R.L.

    1996-03-01

    In recent years main steam isolation valve (MSIV operating problems have resulted in significant operational transients (e.g., spurious reactor trips, steam generator dry out, excessive valve seat leakage), increased cost, and decreased plant availability. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System has been conducted for several types of MSIVs and valve operators for both boiling-water reactors and pressurized-water reactors. The focus of this review is on MSIV failures modes, actuator failure modes, consequences of failure on plant operations, method of failure detection, and major stressors affecting both valves and valve operators

  1. 77 FR 11532 - Notice of Attendance at ISO New England and NEPOOL Meetings

    Science.gov (United States)

    2012-02-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Attendance at ISO New England... members of the Commission and Commission staff may attend upcoming ISO New England Inc. (ISO-NE) and New..., the Commission and Commission staff may monitor the various meetings posted on the ISO-NE Web site...

  2. ISO 14001 ENVIRONMENTL MANAGEMENT SYSTEMS IN GOVERNMENT AND INDUSTRY

    Science.gov (United States)

    Two new USEPA documents address environmental management systems (EMS) from the perspectives of government and industry and are offered as tools for understanding the process of the ISO 14000 Standards development and usefulness of an EMS approach. The first document, ISO 14001 -...

  3. IS ISO 9000 CERTIFICATION LOSING ITS CREDIBILITY?

    Directory of Open Access Journals (Sweden)

    P.R. Ramesh

    2013-03-01

    Full Text Available ISO certification was a great hope for many stakeholders in India for making the country strong in terms of quality practices. It was a blessing in disguise when in early nineties; buyers were imposing conditions that you should be ISO compliant to do business with them. ISO was a great system to bring in improvements in the way an organization functions. But unfortunately some have adopted a short cut approach in getting the certification done. It is only just before the audit team comes for re-inspection that firms start removing dust from the quality manual files so that they can pretend that that they follow those systems. But a real commitment to adhering to these systems is missing. The paper describes such scenario existing in some quarters in India and warns against such practices for the overall good of the system.

  4. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  5. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  6. Mitral valve-sparing procedures and prosthetic heart valve failure: A case report

    Science.gov (United States)

    Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J

    2009-01-01

    Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993

  7. Analysis of aortic root surgery with composite mechanical aortic valve conduit and valve-sparing reconstruction.

    Science.gov (United States)

    Dias, Ricardo Ribeiro; Mejia, Omar Asdrubal Vilca; Fiorelli, Alfredo Inácio; Pomerantzeff, Pablo Maria Alberto; Dias, Altamiro Ribeiro; Mady, Charles; Stolf, Noedir Antonio Groppo

    2010-01-01

    Comparative analysis of early and late results of aortic root reconstruction with aortic valve sparing operations and the composite mechanical valve conduit replacement. From November 2002 to September 2009, 164 consecutive patients with mean age 54 ± 15 years, 115 male, underwent the aortic root reconstruction (125 mechanical valve conduit replacements and 39 valve sparing operations). Sixteen percent of patients had Marfan syndrome and 4.3% had bicuspid aortic valve. One hundred and forty-four patients (88%) were followed for a mean period of 41.1 ± 20.8 months. The hospital mortality was 4.9%, 5.6% in operations with valved conduits and 2.6% in the valve sparing procedures (P valve sparing operations, respectively (95% CI = 70% - 95%, P = 0.001), (95% CI = 82% - 95% P = 0.03) and (95% CI = 81% - 95%, P = 0.03). Multivariate analysis showed that creatinine greater than 1.4 mg/dl, Cabrol operation and renal dialysis were predictors of mortality, respectively, with occurrence chance of 6 (95% CI = 1.8 - 19.5, P = 0.003), 12 (95% CI = 3 - 49.7, P = 0.0004) and 16 (95% CI = 3.6 - 71.3, P = 0.0002). The aortic root reconstruction has a low early and late mortality, high survival free of complications and low need for reoperation. During the late follow-up, valve sparing aortic root reconstructions presented fewer incidences of bleeding, thromboembolic events and endocarditis.

  8. ISO Results Presented at International Astronomical Union

    Science.gov (United States)

    1997-08-01

    Some of the work being presented is collected in the attached ESA Information Note N 25-97, ISO illuminates our cosmic ancestry. A set of six colour images illustrating various aspects have also been released and are available at http://www.estec.esa.nl/spdwww/iso1808.htm or in hard copy from ESA Public Relations Paris (fax:+33.1.5369.7690). These pictures cover: 1. Distant but powerful infrared galaxies 2. A scan across the milky way 3. Helix nebula: the shroud of a dead star 4. Supernova remnant Cassiopeia A 5. Trifid nebula: a dusty birthplace of stars 6. Precursors of stars and planets The International Astronomical Union provides a forum where astronomers from all over the world can develop astronomy in all its aspects through international co-operation. General Assemblies are held every three years. It is expected that over 1600 astronomers will attend this year's meeting, which is being held in Kyoto, Japan from 18-30 August. Further information on the meeting can be found at: www.tenmon.or.jp/iau97/ . ISO illuminates our cosmic ancestry The European Space Agency's Infrared Space Observatory, ISO, is unmatched in its ability to explore and analyse many of the universal processes that made our existence possible. We are children of the stars. Every atom in our bodies was created in cosmic space and delivered to the Sun's vicinity in time for the Earth's formation, during a ceaseless cycle of birth, death and rebirth among the stars. The most creative places in the sky are cool and dusty, and opaque even to the Hubble Space Telescope. Infrared rays penetrating the dust reveal to ISO hidden objects, and the atoms and molecules of cosmic chemistry. "ISO is reading Nature's recipe book," says Roger Bonnet, ESA's director of science. "As the world's only telescope capable of observing the Universe over a wide range of infrared wavelengths, ISO plays an indispensable part in astronomical discoveries that help to explain how we came to exist." This Information Note

  9. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  10. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    Science.gov (United States)

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  12. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    Science.gov (United States)

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  13. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    Science.gov (United States)

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  15. Revision of the ISO and EN radiation sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.; Hansen, J.

    2002-01-01

    The radiation sterilization standards, ISO 11137 and EN 552, are now being revised under "ISO lead", with the aim of producing only one international standard, although in four parts: (1) requirements. (2) dose-setting methods, (3) dose-substantiation methods and (4) dosimetry. Several aspects...

  16. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    McGough, C.B.

    1974-01-01

    The United States Liquid Metal Fast Breeder Reactor program (LMFBR) includes an extensive program devoted to the development of small sodium valves. This program is now focused on the development and production of valves for the Fast Flux Test Facility (FFTF) now under construction near Richland, Washington. Other AEC support facilities, such as various test loops located at the Liquid Metal Engineering Center (LMEC), Los Angeles, California, and at the Hanford Engineering Development Laboratory (HEDL), Richland, Washington, also have significant requirements for small sodium valves, and valves similar in design to the FFTF valves are being supplied to these AEC laboratories for use in their critical test installations. A principal motivation for these valve programs, beyond the immediate need to provide high-reliability valves for FFTF and the support facilities, is the necessity to develop small valve technology for the Clinch River Breeder Reactor Plant (CRBRP). FFTF small sodium valve design and development experience will be directly applied to the CRBRP program. Various test programs have been, and are being, conducted to verify the performance and integrity of the FFTF valves, and to uncover any potential problems so that they can be corrected before the valves are placed in service in FFTF. The principal small sodium valve designs being utilized in current U.S. programs, the test and operational experience obtained to date on them, problems uncovered, and future development and testing efforts being planned are reviewed. The standards and requirements to which the valves are being designed and fabricated, the valve designs in current use, valve operators, test and operating experience, and future valve development plans are summarized. (U.S.)

  17. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  18. Three dimensional rotational angiography for assessment of coronary arteries during melody valve implantation: introducing a technique that may improve outcomes.

    Science.gov (United States)

    Pockett, C R; Moore, J W; El-Said, H G

    2017-02-01

    Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established. To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes. All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed. 31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis). As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.

  19. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  20. Measuring the Software Product Quality during the Software Development Life-Cycle: An ISO Standards Perspective

    OpenAIRE

    Rafa E. Al-Qutaish

    2009-01-01

    Problem statement: The International Organization for Standardization (ISO) published a set of international standards related to the software engineering, such as ISO 12207 and ISO 9126. However, there is a set of cross-references between the two standards. Approach: The ISO 9126 on software product quality and ISO 12207 on software life cycle processes had been analyzed to invistigate the relationships between them and to make a mapping from the ISO 9126 quality characteristics to the ISO 1...

  1. Analysis of a postulated pipe rupture and subsequent check valve slam of a PWR feedwater line

    International Nuclear Information System (INIS)

    Chang, K.C.; Adams, T.M.

    1983-01-01

    System designs criteria employed in the design of pressurized water reactors (PWR) requires that, for a postulated instantaneous guillotine rupture anywhere in the steam generator feedwater system, no more than one steam generator can be allowed to blowdown. Feedwater systems in many PWR's consist of pipe lines running from the feedwater pumps into a common feedwater header then branching into each steam generator from the header. The feedwater piping to each steam generator contains swing check valves to prevent reverse flow from the steam generator. This activation of some or all of these check valves significantly complicates the system structural analysis in that not only the blowdown forces resulting from the postulated pipe rupture, but also the water hammer loads resulting from closure of the check valve at high reverse flow velocities must be considered. The loads resulting from system blowdown and check valve closure are axial in nature. Peak loads ranging from 130000 lbs. to 180000 lbs. are not uncommon and are layout dependent. The analysis and design to withstand this transient loading deviates from the usual feedwater line design in that supports are required along the piping axis in the direction normal to the usual seismic supports. A brief and general discussion of the methods employed in the generation of the thermal-hydraulic loadings is presented. However, the discussion emphasizes the piping and piping support structural design and analysis method and approaches used in evaluating a selected portion of such a feedwater system. (orig./RW)

  2. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  3. LOFT pressurizer safety: relief valve reliability

    International Nuclear Information System (INIS)

    Brown, E.S.

    1978-01-01

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice

  4. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  5. Cavitation guide for control valves

    International Nuclear Information System (INIS)

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation

  6. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  7. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  8. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  9. Steroid therapy and conduction disturbances after transcatheter aortic valve implantation.

    Science.gov (United States)

    Havakuk, Ofer; Konigstein, Maayan; Ben Assa, Eyal; Arbel, Yaron; Abramowitz, Yigal; Halkin, Amir; Bazan, Samuel; Shmilovich, Haim; Keren, Gad; Finkelstein, Ariel; Banai, Shmuel

    2016-10-01

    Direct mechanical compression of the frame struts on the adjacent bundle branch with local inflammatory reaction might cause conduction system disturbances and need for pacemaker implantation following transcatheter aortic valve implantation (TAVI). We assessed the impact of preprocedural anti-inflammatory steroid therapy on the occurrence of conduction disturbances following TAVI. From a cohort of 324 patients who underwent transfemoral TAVI, 39 (12%) were pretreated with steroids because of iodine allergy (n=29) or active obstructive pulmonary disease (n=10). We compared the rate of occurrence of new conduction disturbances and pacemaker implantation between TAVI patients with (n=39) and without (n=285) steroid treatment, using Cox logistic regression estimates and proportional hazards models. The overall occurrence of new conduction defects and the need for new pacemaker implantation were similar among steroid and non-steroid-treated patients (38.4% vs 37.5% and 25.6% vs 25.3%, respectively). New conduction disturbances were more prevalent in patients treated with CoreValve prosthesis, low implantation, and smaller aortic annulus diameter (P<.001, P<.001, and P=.006, respectively). Thirty-day mortality and complication rates were similar between the groups. Although safe, steroid treatment prior to TAVI failed to reduce the incidence of new conduction defects and the need for pacemaker implantation. © 2016 John Wiley & Sons Ltd.

  10. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    Directory of Open Access Journals (Sweden)

    Darwazah Ahmad K

    2012-06-01

    Full Text Available Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  11. USGIN ISO metadata profile

    Science.gov (United States)

    Richard, S. M.

    2011-12-01

    The USGIN project has drafted and is using a specification for use of ISO 19115/19/39 metadata, recommendations for simple metadata content, and a proposal for a URI scheme to identify resources using resolvable http URI's(see http://lab.usgin.org/usgin-profiles). The principal target use case is a catalog in which resources can be registered and described by data providers for discovery by users. We are currently using the ESRI Geoportal (Open Source), with configuration files for the USGIN profile. The metadata offered by the catalog must provide sufficient content to guide search engines to locate requested resources, to describe the resource content, provenance, and quality so users can determine if the resource will serve for intended usage, and finally to enable human users and sofware clients to obtain or access the resource. In order to achieve an operational federated catalog system, provisions in the ISO specification must be restricted and usage clarified to reduce the heterogeneity of 'standard' metadata and service implementations such that a single client can search against different catalogs, and the metadata returned by catalogs can be parsed reliably to locate required information. Usage of the complex ISO 19139 XML schema allows for a great deal of structured metadata content, but the heterogenity in approaches to content encoding has hampered development of sophisticated client software that can take advantage of the rich metadata; the lack of such clients in turn reduces motivation for metadata producers to produce content-rich metadata. If the only significant use of the detailed, structured metadata is to format into text for people to read, then the detailed information could be put in free text elements and be just as useful. In order for complex metadata encoding and content to be useful, there must be clear and unambiguous conventions on the encoding that are utilized by the community that wishes to take advantage of advanced metadata

  12. Butterfly valve of all rubber lining type

    International Nuclear Information System (INIS)

    Shimada, Shosaku; Nakatsuma, Sumiya; Sasaki, Iwao; Aoki, Naoshi.

    1982-01-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported. (Kako, I.)

  13. ISO CD 14492

    DEFF Research Database (Denmark)

    Martins, Bo; Kossentini, F.; Arps, R.

    1998-01-01

    This Recommendation | International Standard, informally called JBIG2, defines a coding method for bilevel images, that is, images consisting of a single rectangular bit plane, with each pixel taking on one of just two possible colors. Itis being drafted by the Joint Bi-level Image Experts Group ...... (JBIG), a "Collaborative team" that reports both to ISO/IEC JTC1/SC29/WG1 and to ITU-T/SG8....

  14. Implications of ISO 9000 for personnel dosimetry

    International Nuclear Information System (INIS)

    Yoder, R.C.

    1995-01-01

    Landauer, Inc. has gained approval to provide personnel dosimetry services in several countries. Each experiene reflects the different concerns adopted by national approval agencies. None have adopted ISO 9000 registration as evidence of a suitable quality system of management. Instead, each organization has prepared its own set of requirements with no provisions for recognizing the results of performance tests or audits conducted by other approval organizations. As ISO 9000 has become a communication symbol for commercial organizations dealing with each other, it has not been similarly viewed by radiation regulation bodies. A key reason arises from a tradition to regulate bodies. A key reason arises from a tradition to regulate, not promote, international trade, not encourage innovation, nor foster economic competition. A second reason is the inability to separate the technical requirements from quality assurance. ISO 9000 may become useful once the national technical organizations learn to trust those of other countries

  15. A STUDY OF INDICATIONS, COMPLICATIONS OF PROSTHETIC VALVES AND PROGNOSIS AFTER TREATMENT OF STUCK VALVE

    Directory of Open Access Journals (Sweden)

    Y. V. Subba Reddy

    2017-03-01

    Full Text Available BACKGROUND Implantation of prosthetic cardiac valves to treat haemodynamically significant valvular diseases has become common; however, it is associated with complications. Thus, this study was intended to evaluate the indications for implantation of prosthetic valve and complications after its implantation and prognosis after treatment of one of its complication, i.e. stuck valve. MATERIALS AND METHODS This was a single-centered study wherein 50 patients who came to the emergency department with stuck valve were assessed. The 2D echocardiography was performed in all patients. Thrombolysis was done and the gradients were reassessed. Further response to treatment and development of complications before and after treatment were observed. RESULTS Of total patients, 60% were females. Mean age group was 30-40 yrs. Most of them were asymptomatic for 6 years and there was lack of compliance in 90% of patients. Most common indication for valve replacement was mitral stenosis (60% followed by mitral regurgitation (20%, aortic regurgitation and aortic stenosis (10% and combined mitral and tricuspid regurgitation (10%. Commonest valve was St. Jude (90%. Pannus was observed in 10% patients and thrombus was observed in 50% patients. Most patients had gradients 45/20 mmHg across mitral valve. In about 90% patients, gradients decreased after thrombolysis (12/5 mmHg. The complications after thrombolysis were hemiparesis (4%, death before thrombolysis (6% and death after thrombolysis (4%. CONCLUSION Considering these results, it can be concluded that prosthetic valves are seldom associated with some complications. Further, thrombolysis can be effective in patients with prosthetic valve thrombosis.

  16. Supra-annular Valve-in-Valve implantation reduces blood stasis on the transcatheter aortic valve leaflets.

    Science.gov (United States)

    Vahidkhah, Koohyar; Azadani, Ali N

    2017-06-14

    Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and Valve-in-Valve (ViV) procedures has been increasingly recognized. This study aimed to investigate the effect of positioning of the transcatheter aortic valve (TAV) in ViV setting on the flow dynamics aspect of post-ViV thrombosis by quantifying the blood stasis in the intra-annular and supra-annular settings. To that end, two idealized computational models, representing ViV intra-annular and supra-annular positioning of a TAV were developed in a patient-specific geometry. Three-dimensional flow fields were then obtained via fluid-solid interaction modeling to study the difference in blood residence time (BRT) on the TAV leaflets in the two settings. At the end of diastole, a strip of high BRT (⩾1.2s) region was observed on the TAV leaflets in the ViV intra-annular positioning at the fixed boundary where the leaflets are attached to the frame. Such a high BRT region was absent on the TAV leaflets in the supra-annular positioning. The maximum value of BRT on the surface of non-, right, and left coronary leaflets of the TAV in the supra-annular positioning were 53%, 11%, and 27% smaller compared to the intra-annular positioning, respectively. It was concluded that the geometric confinement of TAV by the leaflets of the failed bioprosthetic valve in ViV intra-annular positioning increases the BRT on the leaflets and may act as a permissive factor in valvular thrombosis. The absence of such a geometric confinement in the ViV supra-annular positioning leads to smaller BRT and subsequently less likelihood of leaflet thrombosis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. IMPLEMENTASI SISTEM MANAJEMEN MUTU BERBASIS ISO 9001:2000 PADA SEKOLAH MENENGAH KEJURUAN

    Directory of Open Access Journals (Sweden)

    Mardi Wiyono

    2012-09-01

    Full Text Available Abstract: The implementation of ISO 9001:2000 quality management system in vocational school. The needs of quality products and services is largerly expanded in various organizations including education. Recently, the vocational schools also realize how important the quality product and service is. For achieving the quality product or service, some organizations implement the concept of ISO 9001:2000 quality management system. In 2006/2007 it is reported that there are some vocational schools have been certified with ISO 9001:2000. ISO 9001 is a serial document consists of Quality Management System Standard which has been refised from its previous standard. ISO 9001:2000 gives a number of prerequisites for organizations having business initialized by design and development, production, installations, and services. The vocational schools which have been certified with ISO 9001:2000, have to be re-accredited after three years of implementation.

  18. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  19. Modelovanje georeferenciranih podataka u katastru nepokretnosti primenom ISO 19100 serije standarda / Spatial data modeling in the real estate cadastre using ISO 19100 series of standards

    Directory of Open Access Journals (Sweden)

    Mirko N. Petrović

    2010-01-01

    Full Text Available Potreba za standardizacijom u oblasti geografskih informacionih sistema odavno postoji. Međunarodne aktivnosti na ovom polju rezultirale su uspostavljanjem ISO 19100 serije standarda, kojima se regulišu različiti aspekti na polju geoinformatike. U članku su opisane mogućnosti primene relevantnih standarda iz serije ISO 19100 u modelovanju georeferenciranih podataka za katastar nepokretnosti. / Introduction Standardization in geo-information technologies contributes to the establishment of efficient information functions, their greater stability and easier transition. Application of international, national and internal standards in the process of developing software products in the field of geo-information technology creates conditions for the development of efficient, low cost, reliable and secure software products. Spatial data modeling basics for real estate cadastre In terms of modeling, the spatial information of real estate cadastre is based on the vector data model which is suitable for modeling objects with a smaller number of properties with emphasis on the position. The vector spatial data model consists of two components: spatial and descriptive. The basis of the spatial one is geometry that contains metric data usually given in coordinates of a reference system. Geometry and Topology uniquely determine the shape, size and position of the object model in space, i.e. they represent its spatial component. Merging the spatial component with the descriptive one results in a completely defined object from the real world. Elements of spatial data quality Spatial data quality can be reviewed through a set of the following elements: origin, positional accuracy, attribute accuracy, completeness, logical consistency, semantic accuracy and the time information. The elements of spatial data quality listed above are provided using ISO 19100 series of standards. Application of ISO19100 series of standards in spatial data modeling for real

  20. Reasons to Adopt ISO 50001 Energy Management System

    Directory of Open Access Journals (Sweden)

    Frederic Marimon

    2017-09-01

    Full Text Available Purpose: The main aim of this paper is to analyze the relationships between the corporate motivations that lead organizations to establish the ISO 50001 Energy Management System (EnMS standard, and the difficulties and benefits derived from its adoption. Design/methodology/approach: Three independent exploratory factor analyses (EFA were conducted in order to identify (i sources of motivation: social requirements, ecology drivers, and competitive advantage; (ii the difficulties of an ISO 50001 adoption: operational difficulties and organizational difficulty; and (iii types of benefits: ecological benefits and operational benefits. In a second step, an exploratory path analysis, performed through Structural Equation Modeling (SEM, was used to analyze the relations among motivation, difficulties, and benefits related to the adoption of the ISO 50001 standard. Findings: Social requirements explain operational difficulties, which in turn impacts on operational benefits. Ecology drivers are directly related to ecological benefits. Organizational difficulties have an inverse relationship with operational and ecological benefits. Operational difficulties are related to operational benefits and ecological benefits. Research limitations/implications: The questionnaire was disseminated to 87 Spanish companies with ISO 50001 certification. Managers and other practitioners such as consultants, auditing companies, and official organizations in charge of developing standards might find useful implications. Originality/value: The standard was published in 2011 by the International Organization for Standardization (ISO. This paper contributes to assessment of the benefits of the standard by collecting information directly from the pioneer organizations that have adopted it, and provides clues on how to implement the standard and improve it in future.

  1. Energy care in relation to your management system. Linking lists between the Reference Energy Care and ISO 14001, ISO 9001 and HACCP; Energiezorg in relatie tot uw zorgsysteem. Linking lists tussen de Referentie Energiezorg en ISO 14001, ISO 9001 en HACCP

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Several so-called care systems are in use at institutes and companies. For efficiency reasons it makes sense to integrate an energy care system to the existing care system. For the so-called Reference Energy Care, developed by the Netherlands Agency for Energy and the Environment (Novem) links to three of the most important care systems have been elaborated: environmental care according to ISO 14001, the quality care system ISO 9001:2000 and the food safety system Hazard Analysis Critical Control Points (HACCP). The elaboration resulted in three tables, indicating the connections ('linking lists') between each of those care systems and the Reference Energy Care system and how energy care can be integrated into those systems. [Dutch] Bij instellingen en bedrijven zijn diverse zorgsystemen in gebruik. Het is zinvol om energiezorg - waar mogelijk - in een dergelijk bestaand systeem op te nemen. Meerdere zorgsystemen naast elkaar in stand houden is minder efficient dan de systemen integreren tot een systeem. Novem heeft daarom voor haar Referentie Energiezorg de link laten uitwerken naar drie van de meest voorkomende systemen: milieuzorg volgens ISO 14001, het kwaliteitszorgsysteem ISO 9001:2000 en het voedselveiligheidssysteem HACCP (Hazard Analysis Critical Control Points). Hieruit zijn drie tabellen voortgekomen, die aangeven welke verbanden er zijn tussen elk van deze zorgsystemen en de Referentie Energiezorg en hoe u energiezorg kunt integreren in elk van deze systemen. Deze tabellen worden aangeduid als 'linking lists' en u kunt ze gebruiken als hulpmiddel bij het integreren van energiezorg in uw eigen zorgsysteem. U vindt ze in deze brochure.

  2. Energy care in relation to your management system. Linking lists between the Reference Energy Care and ISO 14001, ISO 9001 and HACCP; Energiezorg in relatie tot uw zorgsysteem. Linking lists tussen de Referentie Energiezorg en ISO 14001, ISO 9001 en HACCP

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Several so-called care systems are in use at institutes and companies. For efficiency reasons it makes sense to integrate an energy care system to the existing care system. For the so-called Reference Energy Care, developed by the Netherlands Agency for Energy and the Environment (Novem) links to three of the most important care systems have been elaborated: environmental care according to ISO 14001, the quality care system ISO 9001:2000 and the food safety system Hazard Analysis Critical Control Points (HACCP). The elaboration resulted in three tables, indicating the connections ('linking lists') between each of those care systems and the Reference Energy Care system and how energy care can be integrated into those systems. [Dutch] Bij instellingen en bedrijven zijn diverse zorgsystemen in gebruik. Het is zinvol om energiezorg - waar mogelijk - in een dergelijk bestaand systeem op te nemen. Meerdere zorgsystemen naast elkaar in stand houden is minder efficient dan de systemen integreren tot een systeem. Novem heeft daarom voor haar Referentie Energiezorg de link laten uitwerken naar drie van de meest voorkomende systemen: milieuzorg volgens ISO 14001, het kwaliteitszorgsysteem ISO 9001:2000 en het voedselveiligheidssysteem HACCP (Hazard Analysis Critical Control Points). Hieruit zijn drie tabellen voortgekomen, die aangeven welke verbanden er zijn tussen elk van deze zorgsystemen en de Referentie Energiezorg en hoe u energiezorg kunt integreren in elk van deze systemen. Deze tabellen worden aangeduid als 'linking lists' en u kunt ze gebruiken als hulpmiddel bij het integreren van energiezorg in uw eigen zorgsysteem. U vindt ze in deze brochure.

  3. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  4. Valve-stem-packing improvement study. Final report

    International Nuclear Information System (INIS)

    Adey, C.W.; Klein, J.J.

    1982-08-01

    By employing questionnaires and face-to-face interviews with valve and valve packing manufacturers, as well as nuclear plant personnel, an understanding of valve stem packing leakage problems from each of the three viewpoints was developed. This information, in-house experience, and available technical literature were used to develop specific recommendations for valve manufacturers, valve packing manufacturers, and nuclear plant valve users. It was generally recommended that each these groups make better use of graphite packing. The questionnaires and interviews indicated that increased usage of graphite packing over the last few years has reduced the incidence of valve packing problems. To confirm this, a survey of Licensee Event Reports (LERs) from 1972 to 1980 was undertaken using the keywords Valve and Packing. A statistical analysis of the LER data confirms that the adoption of graphite packing has significantly reduced valve stem leakage

  5. 21 CFR 184.1165 - n-Butane and iso-butane.

    Science.gov (United States)

    2010-04-01

    ... FOR HUMAN CONSUMPTION (CONTINUED) DIRECT FOOD SUBSTANCES AFFIRMED AS GENERALLY RECOGNIZED AS SAFE Listing of Specific Substances Affirmed as GRAS § 184.1165 n-Butane and iso-butane. (a) n-Butane and iso..., odorless, flammable gases at normal temperatures and pressures. They are easily liquefied under pressure at...

  6. Juhtimissüsteemide selgroog. Lean ning ISO - terviklahendused tootmise haldamiseks / Anton Ovsjankin

    Index Scriptorium Estoniae

    Ovsjankin, Anton

    2011-01-01

    Kasvanud on juurutatavate Lean ja ISO süsteemide arv, kuid on kasvanud ka nende juurutamise ja arendamisega seotud ebaõnnestumiste arv. Põhjustest, miks jäävad paljud Leani ja ISO juurutanud ettevõtted ilma lubatud tulemusteta. Leani ja ISO haldamiseks vajalikest teguritest

  7. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  8. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  9. ISO 14000: Review and guidelines for the photovoltaic industry

    Energy Technology Data Exchange (ETDEWEB)

    DePhillips, M.P.

    1997-08-01

    The International Organization for Standardization (ISO) has released and is in the process of ratifying a new set of environmental management system standards, ISO 14000. These voluntary international standards will have a significant impact on how companies throughout the international community manage their environmental programs. Initially this impact will result in increased international trade opportunities due to the anticipated customer requirement for suppliers to demonstrate certification. Other potential impacts will benefit both companies engaged in international commerce and companies with a domestic focus. These would include installing a cohesive system to manage environmental matters, participation within a new regulatory paradigm, and adhering to a potentially new set of legal standards. The wide range of potential environmental, commercial, legal and regulatory benefits offered by ISO 14000 offer most companies significant reason to explore the possibilities of implementing an environmental management system. Organizations will be able to anticipate and meet growing environmental expectations and to ensure ongoing compliance with national and international requirements as well as satisfy the growing demands of customers, stakeholders and the interested public. As an emerging industry with significant international ties, the photovoltaic (PV) community will be effected from these standards if they do become globally adopted. In fact some major players in the PV industry have recently received certification to ISO 9000. This again demonstrates a trend within the industry to move toward a uniform system approach to management. This paper will expose interested parties within the PV industry to the details of ISO 14000 and will assist decision makers assess the various possibilities for implementation certification of ISO 14000 for an individual facility.

  10. Percutaneous pulmonary valve implantation in patients with dysfunction of a "native" right ventricular outflow tract - Mid-term results.

    Science.gov (United States)

    Georgiev, Stanimir; Tanase, Daniel; Ewert, Peter; Meierhofer, Christian; Hager, Alfred; von Ohain, Jelena Pabst; Eicken, Andreas

    2018-05-01

    To investigate the feasibility and mid-term results of percutaneous pulmonary valve implantation (PPVI) in patients with conduit free or "native" right ventricular outflow tracts (RVOT). We identified all 18 patients with conduit free or "native" right ventricular outflow tract, who were treated with percutaneous pulmonary valve implantation (PPVI) in our institution. They were divided into two groups - these in whom the central pulmonary artery was used as an anchoring point for the preparation of the landing zone (n=10) for PPVI and these, in whom a pulmonary artery branch was used for this purpose (n=8). PPVI was performed successfully in all patients with significant immediate RVOT gradient and pulmonary regurgitation grade reduction. Four patients had insignificant paravalvular regurgitation. In one patient the valve was explanted after 4months because of bacterial endocarditis. A follow-up of 19 (4-60) months showed sustained good function of the other implanted valves. The MRI indexed right ventricular end diastolic volume significantly decreased from 108(54-174) ml/m 2 before the procedure to 76(60-126) ml/m 2 six months after PPVI, p=0.01. PPVI is feasible with good mid-term results in selected patients with a "native" RVOT without a previously implanted conduit. Creating a stable landing zone with a diameter less than the largest available valve (currently 29mm) is crucial for the technical success of the procedure. Further studies and the development of new devices could widen the indications for this novel treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Gate valve and motor-operator research findings

    International Nuclear Information System (INIS)

    Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Russell, M.J.; Bramwell, D.

    1995-09-01

    This report provides an update on the valve research being sponsored by the US Nuclear Regulatory Commission (NRC) and conducted at the Idaho National Engineering Laboratory (INEL). The research addresses the need to provide assurance that motor-operated valves can perform their intended safety function, usually to open or close against specified (design basis) flow and pressure loads. This report describes several important developments: Two methods for estimating or bounding the design basis stem factor (in rising-stem valves), using data from tests less severe than design basis tests; a new correlation for evaluating the opening responses of gate valves and for predicting opening requirements; an extrapolation method that uses the results of a best effort flow test to estimate the design basis closing requirements of a gate valve that exhibits atypical responses (peak force occurs before flow isolation); and the extension of the original INEL closing correlation to include low- flow and low-pressure loads. The report also includes a general approach, presented in step-by-step format, for determining operating margins for rising-stem valves (gate valves and globe valves) as well as quarter-turn valves (ball valves and butterfly valves)

  12. ISO 9000. Guidelines to increased costs and reduced product quality

    International Nuclear Information System (INIS)

    Reedy, R.F.

    1994-01-01

    Many US companies are considering being registered to the provisions of ISO 9000, International Standards for Quality Management. One important problem with the document is that ISO 9000 is not focused on control of product quality. The quality assurance rules established in ISO 9000 have been used in the US for more than 25 years with disastrous financial consequences and little, if any, improvement in quality and safety. These rules are so reliant on documentation and strict compliance that ensuring products comply with specifications has become a secondary issues. That is not what was intended, but it is the result. ISO 9000 program can work effectively only when the top executive responsible for engineering or production takes full responsibility for interpretation and implementation of the quality assurance program. 3 refs., 1 tab

  13. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  14. OntoCR: A CEN/ISO-13606 clinical repository based on ontologies.

    Science.gov (United States)

    Lozano-Rubí, Raimundo; Muñoz Carrero, Adolfo; Serrano Balazote, Pablo; Pastor, Xavier

    2016-04-01

    To design a new semantically interoperable clinical repository, based on ontologies, conforming to CEN/ISO 13606 standard. The approach followed is to extend OntoCRF, a framework for the development of clinical repositories based on ontologies. The meta-model of OntoCRF has been extended by incorporating an OWL model integrating CEN/ISO 13606, ISO 21090 and SNOMED CT structure. This approach has demonstrated a complete evaluation cycle involving the creation of the meta-model in OWL format, the creation of a simple test application, and the communication of standardized extracts to another organization. Using a CEN/ISO 13606 based system, an indefinite number of archetypes can be merged (and reused) to build new applications. Our approach, based on the use of ontologies, maintains data storage independent of content specification. With this approach, relational technology can be used for storage, maintaining extensibility capabilities. The present work demonstrates that it is possible to build a native CEN/ISO 13606 repository for the storage of clinical data. We have demonstrated semantic interoperability of clinical information using CEN/ISO 13606 extracts. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Strut fracture of Björk-Shiley convexo-concave valve in Japan--risk of small valve size--.

    Science.gov (United States)

    Watarida, S; Shiraishi, S; Nishi, T; Imura, M; Yamamoto, Y; Hirokawa, R; Fujita, M

    2001-08-01

    The Björk-Shiley convexo-concave (BSCC) prosthetic valve was introduced in 1979. Between 1979 and 1986, approximately 86,000 BSCC valves were implanted. By December 31, 1994, 564 complete strut fractures had been reported to the manufacture. We experienced a case of an outlet strut fracture and investigated the risk of BSCC prosthetic valve fractures in Japan. To investigate the risk factor of a strut fracture in Japan, we investigated published cases of strut fractures. Between 1979 and 1986, 2021 BSCC valves were implanted in Japan. By January 31, 2000, 11 complete strut fractures of 60-degree BSCC valves including our case had occurred. The patients were eight males and three females. The average age at valve replacement was 42.4+/-8.1 years, and nine of eleven (81.8%) were patients valve fractured was 47.7+/-6.4 years, and eight of eleven (72.7%) were patients valve were 27 mm (n=5) (45.5%), 29 mm (n=3) (27.2%), and 31 mm (n=3) (27.2%). Four patients died and seven patients survived. Although only 11 BSCC valve struts fractured and statistical analysis could not be performed, our findings suggest that the high risk group for a strut fracture in Japan is young male patients with a mitral valve, >= 27 mm in size with BSCC models manufactured before March 1982. When following-up patients with BSCC models manufactured before March 1982, the possibility of a strut fracture in all BSCC valve sizes should be kept in mind.

  16. 75 FR 51996 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Science.gov (United States)

    2010-08-24

    ... Midwest ISO Meetings August 16, 2010. The Federal Energy Regulatory Commission hereby gives notice that members of the Commission and Commission staff may attend the following Midwest ISO-related meetings...., St. Paul, MN) [cir] September 15 [cir] October 20 [cir] November 17 [cir] December 1 Midwest ISO...

  17. ISO celebrates its prolonged life with a video of Jupiter

    Science.gov (United States)

    1997-07-01

    This is excellent news for astronomers and especially for the multinational teams, with leaders in France, Germany, the Netherlands and the United Kingdom, who spent many years devising the four instruments served by ISO's telescope. The camera ISOCAM, the photometer ISOPHOT, the Short Wavelength Spectrometer and the Long Wavelength Spectrometer span between them an unprecedented range of infrared wavelengths from 2 to 200 microns. The atmosphere of Jupiter is one of the cool and cloudy places attracting ISO's attention, and ESA today releases a video of unprecedented images of Jupiter. The planet changes its appearance drastically as the camera ISOCAM scans a range of 90 different infrared wavelengths. Picture by picture, ISOCAM picks out different features of the atmosphere's composition and behaviour. These and other results from ISO will enable scientists to sharpen their ideas about how Jupiter's weather works. "ISO is giving us a new impression of the giant planets of the Solar System," comments Roger Bonnet, ESA's director of science. "Not just Jupiter, but Saturn, Uranus and Neptune too. By observing the planets across its very wide range of infrared wavelengths, ISO can see features overlooked even by spacecraft visiting the planets. The remarkable movie of Jupiter released today represents only a few per cent of ISO's wavelength range, yet every image tells its own story." More information about the Jupiter video appears later in this Information Note. How ISO's cold telescope beat the calendar The need to keep ISO's telescope and instruments chilled to a very low temperature sets a limit to their useful operating life. ISO was supplied with more than 2000 litres of superfluid helium to cool it. Slow evaporation maintains key parts of the spacecraft at temperatures close to absolute zero, below minus 271 degrees C. The rate of loss of helium was expected to be about 3 litres a day, but the cryogenic system could not be tested in exactly the conditions

  18. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Directory of Open Access Journals (Sweden)

    Ben Zhang

    Full Text Available Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach.We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve, weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically.Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically

  19. Valve-sparing and valve-replacing techniques for aortic root replacement in patients with Marfan syndrome: Analysis of early outcome.

    Science.gov (United States)

    Volguina, Irina V; Miller, D Craig; LeMaire, Scott A; Palmero, Laura C; Wang, Xing Li; Connolly, Heidi M; Sundt, Thoralf M; Bavaria, Joseph E; Dietz, Harry C; Milewicz, Dianna M; Coselli, Joseph S

    2009-05-01

    A prospective, international registry study was initiated to provide contemporary comparative data on short-term clinical outcomes after aortic valve-sparing and aortic valve-replacing root operations in patients with Marfan syndrome. The purpose of this initial report is to describe the study design and to compare early outcomes in the first 151 enrolled patients. We assessed 30-day outcomes in 151 patients who met strict Ghent diagnostic criteria for Marfan syndrome and underwent aortic root replacement with either valve-replacing (n = 46) or valve-sparing techniques (n = 105) at one of 18 participating centers. In the valve replacement group, a mechanical composite valve graft was used in 39 (85%) patients and a bioprosthetic valve in 7 (15%). In the valve-sparing group, David V procedures were performed in 57 (54%) patients, David I in 38 (36%), David IV in 8 (8%), Florida sleeve in 1 (1%), and Yacoub remodeling in 1 (1%). No in-hospital or 30-day deaths occurred. Despite longer crossclamp and cardiopulmonary bypass times in the valve-sparing group, there were no significant between-group differences in postoperative complications. Thirty-day valve-related complications occurred in 2 (4%) patients undergoing valve replacement and in 3 (3%) undergoing valve-sparing procedures (P = .6). The analysis of early outcomes revealed that valve-sparing techniques were the most common approach to root replacement in patients with Marfan syndrome in these centers. The complexity of valve-sparing root replacement did not translate into any demonstrable adverse early outcomes. Subsequent analysis will compare the 3-year durability of these two surgical approaches.

  20. Guidelines for valves in tritium service

    International Nuclear Information System (INIS)

    Weaver, W.W.

    1994-01-01

    Some undesirable practices and misapplications that caused valve-related failures are examined, and future courses of action are recommended to avoid repetition of these events. Desirable valve characteristics and practices that should be considered when selecting valves for use in tritium service are also discussed. Supporting logic for the desirability of these features is presented by discussing the mechanisms of valve degradation followed by examples of related events. Desirable valve and system features and operational actions are grouped into two categories: strongly recommended and recommended. 13 refs., 1 fig

  1. An analytical investigation on the valve and centrifugal pump speed control with a constant differential pressure across the valve

    International Nuclear Information System (INIS)

    Jung, B. R.; Joo, K. I.; Lee, B. J.; Baek, S. J.; Noh, T. S.

    2003-01-01

    A valve opening and centrifugal pump speed control was investigated analytically in a simple pumping system where the differential pressure across the control valve is maintained constant over the required flow range. The valve control program was derived analytically only as a function of the required flow rate to maintain the constant differential pressure across the valve. The centrifugal pump speed control program was also derived analytically for the required flow rate for the constant differential pressure across the control valve. These derivations theoretically show that the independent control is possible between the valve and pump speed in a system with a constant valve pressure drop. In addition, it was shown that a linear pump speed control is impossible in maintaining the constant valve pressure drop

  2. ISO standardization in nuclear technology

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D [Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia); Cermak, O [Urad pro Normalizaci a Mereni, Prague (Czechoslovakia)

    1984-10-01

    The activity is described of the technical commission ISO/TC 85 which is currently divided into 4 subcommissions (SC) and 24 working groups. SC 1 ''Terminology, definitions, units, abbreviations'' has one working group. The most important document of this SC is ISO 921-1972 (Dictionary of nuclear technology). SC 2 ''Radiation protection'' has 9 working groups and has processed standards in dosimetry. SC 3 ''Technology of power reactors'' has 6 working groups and its work is related to IAEA activities within the NUSS program. SC 4 ''Technology of nuclear fuels'' has 8 working groups. SC 4 has compiled the basic standards for sealed sources and methods of testing their tightness. The results of the work of this group have been reflected into the standardization work of CMEA. A list is given of published international standards within TC 85.

  3. Butterfly valve torque prediction methodology

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Sharma, V.; Kalsi, M.S.; Wolfe, K.

    1994-01-01

    As part of the Motor-Operated Valve (MOV) Performance Prediction Program, the Electric Power Research Institute has sponsored the development of methodologies for predicting thrust and torque requirements of gate, globe, and butterfly MOVs. This paper presents the methodology that will be used by utilities to calculate the dynamic torque requirements for butterfly valves. The total dynamic torque at any disc position is the sum of the hydrodynamic torque, bearing torque (which is induced by the hydrodynamic force), as well as other small torque components (such as packing torque). The hydrodynamic torque on the valve disc, caused by the fluid flow through the valve, depends on the disc angle, flow velocity, upstream flow disturbances, disc shape, and the disc aspect ratio. The butterfly valve model provides sets of nondimensional flow and torque coefficients that can be used to predict flow rate and hydrodynamic torque throughout the disc stroke and to calculate the required actuation torque and the maximum transmitted torque throughout the opening and closing stroke. The scope of the model includes symmetric and nonsymmetric discs of different shapes and aspects ratios in compressible and incompressible fluid applications under both choked and nonchoked flow conditions. The model features were validated against test data from a comprehensive flowloop and in situ test program. These tests were designed to systematically address the effect of the following parameters on the required torque: valve size, disc shapes and disc aspect ratios, upstream elbow orientation and its proximity, and flow conditions. The applicability of the nondimensional coefficients to valves of different sizes was validated by performing tests on 42-in. valve and a precisely scaled 6-in. model. The butterfly valve model torque predictions were found to bound test data from the flow-loop and in situ testing, as shown in the examples provided in this paper

  4. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  5. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  6. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  7. Experimental investigation of the fluid dynamic efficiency of a high performance multi-valve internal combustion engine during the intake phase: Influence of valve-valve interference phenomena

    Directory of Open Access Journals (Sweden)

    Algieri Angelo

    2013-01-01

    Full Text Available The purpose of the present work is the analysis of the fluid dynamic behavior of a high performance internal combustion engine during the intake phase. In particular, a four-valve spark-ignition engine has been characterized at the steady flow rig. Dimensionless discharge coefficients have been used to define the global fluid dynamic efficiency of the intake system, while the Laser Doppler Anemometry (LDA technique has been employed to evaluate the mean flow in the valve curtain area and to characterise the interference phenomena between the two intake valves. The investigation has shown the significant influence of the valve lift on the volumetric efficiency of the intake apparatus. Moreover, the experimental analysis has highlighted that the valve-valve interference phenomena have a relevant impact on the head breathability, on the flow development within the combustion chamber and on the velocity standard deviations.

  8. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models.

    Science.gov (United States)

    Scotten, Lawrence N; Siegel, Rolland

    2015-08-01

    Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring

  9. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    Science.gov (United States)

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P prosthetic valve security.

  10. Energy management systems in the practice. ISO 50001. A guideline for companies and institutions; Energiemanagementsysteme in der Praxis. ISO 50001. Leitfaden fuer Unternehmen und Organisationen

    Energy Technology Data Exchange (ETDEWEB)

    Kohlenborn, Walter; Kabisch, Sibylle; Klein, Johanna; Richter, Ina; Schuermann, Silas

    2012-06-15

    The guideline under consideration is an updated version of the guideline to the regulation EN 16001 and amended to ISO 50001. This contribution supports institutes in the implementation of an energy management system according to ISO 50001. The differences and commonalities to the European environment management system EMAS as well as to the regulation ISO 14001 are described. EMAS certified companies fulfil regularly all conditions of an energy management system. A practised energy management system is an excellent platform for the implementation of EMAS.

  11. 76 FR 4104 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Science.gov (United States)

    2011-01-24

    ... Midwest ISO Meetings January 13, 2011. The Federal Energy Regulatory Commission hereby gives notice that members of the Commission and Commission staff may attend the following Midwest ISO-related meetings...] September 14 [cir] October 19 [cir] November 16 [cir] December 6 Midwest ISO Informational Forum (3 p.m.-5 p...

  12. 75 FR 3228 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Science.gov (United States)

    2010-01-20

    ... Midwest ISO Meetings January 12, 2010. The Federal Energy Regulatory Commission hereby gives notice that members of the Commission and Commission staff may attend the following Midwest ISO-related meetings...] November 17 [cir] December 1 Midwest ISO Informational Forum (3 p.m.-5 p.m., ET) [cir] January 19 [cir...

  13. KSC Center Director Bridges accepts an ISO 9001 certificate from DNV

    Science.gov (United States)

    1998-01-01

    Center Director Roy Bridges displays the ISO 9001 certificate he was awarded by Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. Dalton Lyon of DNV made the presentation, which included a 2000th ISO Certificate Plaque. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world-class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification.

  14. Aortic valve function after bicuspidization of the unicuspid aortic valve.

    Science.gov (United States)

    Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim

    2013-05-01

    Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Competence Requirements of ISO/IEC Standards for Information Security Professionals

    Directory of Open Access Journals (Sweden)

    Natalia G. Miloslavskaya

    2017-11-01

    Full Text Available The rapid progress in the filed of information security (IS puts one in a need of periodic revision of professional competencies (formulated in the federal state educational standards –FSESs and working functions (formulated in the professional standards – PSs. Under these conditions, a timely reaction to everything new that emerges or will appear in modern regulatory documents (primarily in standards is extremely important. We make a forecast for the content of the ISO/IEC 27021 and ISO/IEC 19896 standards drafted by the International Organization for Standardization (ISO, which should contain the requirements for the competencies of IS management system professionals and the competence of IS testers and evaluators. Our forecast takes into account the requirements of the ISO/IEC 27000 standard group and the recommendations of the European e-Competence Framework e-CF 3.0.

  16. A nuclear radiation actuated valve for a nuclear reactor

    International Nuclear Information System (INIS)

    Christiansen, D.W.; Schively, D.P.

    1983-01-01

    The valve has a first part (such as a valve rod with piston) and a second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics which are different. The valve parts are positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system. (author)

  17. Migración de un SGSI basado en ISO/IEC 27001:2005 a la versión ISO/IEC 27001:2013

    OpenAIRE

    Espol; Rendón Freire, María José

    2015-01-01

    Este proyecto tiene como objetivo identificar los cambios en los requisitos de la norma ISO/IEC 27001:2013 respecto a la versión 2005, para lograr la actualización de un sistema de gestión de seguridad de la información basado en ISO/IEC 27001:2005 acorde a lo establecido en el nuevo estándar. Guayaquil Magíster en Seguridad Informática Aplicada

  18. Sifting through the ISO 9000 maze

    International Nuclear Information System (INIS)

    Abraham, K.S.

    1993-01-01

    Various forces in the global upstream market are more frequently pressuring equipment and services firms to be certified according to the latest international standards in order to do business. However, understanding and completing the registration process can appear confusing and intimidating at first glance. This paper reviews the ISO's 9000 series of generic standards that provide quality assurance requirements and management guidance. It describes its applicability to the oil and gas industry which often found itself cut out of international markets because they were not recognized as registered ISO participants. It then describes the registration process, evaluation process, and time tables involved. It also describes the difference performance standards of the 9000 series

  19. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  20. Valve testing for UK PWR safety applications

    International Nuclear Information System (INIS)

    George, P.T.; Bryant, S.

    1989-01-01

    Extensive testing and development has been done by the Central Electricity Generating Board (CEGB) to support the design, construction and operation of Sizewell B, the UK's first PWR. A Blowdown Rig for the Assessment of Valve Operability - (BRAVO) has been constructed at the CEGB Marchwood Engineering Laboratory to reproduce PWR Pressurizer fluid conditions for the full scale testing of Pressurizer Relief System (PRS) valves. A full size tandem pair of Pilot Operated Safety Relief Valves (POSRVs) is being tested under the full range of pressurizer fluid conditions. Tests to date have produced important data on the performance of the valve in its Cold Overpressure protection mode of operation and on methods for the in-service testing of the valve. Also, a full size pressurizer safety valve has been tested under full PRS fluid conditions to develop a methodology for the pre-service testing of the Sizewell valves. Further work will be carried out to develop procedures for the in-service testing of the valve. In the Main Steam Safety Valve test program carried out at the Siemens-KWU Test Facilities, a single MSSV from three potential suppliers was tested under full secondary system conditions. The test results have been analyzed and are reflected in the CEGB's arrangements for the pre-service and in-service testing of the Sizewell MSSVs. Valves required to interrupt pipebreak flow must be qualified for this duty by testing or a combination of testing and analysis. To obtain guidance on the performance of such tests gate and globe valves have been subjected to simulated pipebreaks under PWR primary circuit conditions. In the light of problems encountered with gate valve closure under these conditions, further tests are currently being carried out on the BRAVO facility on a gate valve, in preparation for the full scale flow interruption qualification testing of the Sizewell main steam isolation valve

  1. Valve assembly having remotely replaceable bearings

    International Nuclear Information System (INIS)

    Johnson, E.R.; Tanner, D.E.

    1980-01-01

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings

  2. IMPLEMENTING AN ISO 10001-BASED PROMISE IN INPATIENTS CARE

    Directory of Open Access Journals (Sweden)

    Mohammad Ashiqur Rahman Khan

    2013-09-01

    Full Text Available This paper presents the implementation of a Customer Satisfaction Promise (CSP that requires nurses to introduce themselves and explain the care plan to the patients of a hospital unit in Canada. The CSP implementation, maintenance and improvement activities were based on ISO 10001:2007. Qualitative and quantitative performance data were collected from nurses, the unit manager and patients, and improvement suggestions were made. During the implementation, nurses introduced themselves 95% of the time and explained the care plan 86% of the time. When interviewed, some nurses stated that the CSP was a good reinforcement of a practice already expected of them, which made patients happy, satisfied and more comfortable. Data from a small sample of patients was not adequate in clearly indicating the CSP's performance or improvement, but was useful in validating the survey and the feedback form. To our knowledge, applications of ISO 10001:2007 in health care have not been studied. Furthermore, this paper may be the first example of the integrated use of ISO 10001 and ISO 10002 in health care.

  3. Krox20 defines a subpopulation of cardiac neural crest cells contributing to arterial valves and bicuspid aortic valve.

    Science.gov (United States)

    Odelin, Gaëlle; Faure, Emilie; Coulpier, Fanny; Di Bonito, Maria; Bajolle, Fanny; Studer, Michèle; Avierinos, Jean-François; Charnay, Patrick; Topilko, Piotr; Zaffran, Stéphane

    2018-01-03

    Although cardiac neural crest cells are required at early stages of arterial valve development, their contribution during valvular leaflet maturation remains poorly understood. Here, we show in mouse that neural crest cells from pre-otic and post-otic regions make distinct contributions to the arterial valve leaflets. Genetic fate-mapping analysis of Krox20-expressing neural crest cells shows a large contribution to the borders and the interleaflet triangles of the arterial valves. Loss of Krox20 function results in hyperplastic aortic valve and partially penetrant bicuspid aortic valve formation. Similar defects are observed in neural crest Krox20 -deficient embryos. Genetic lineage tracing in Krox20 -/- mutant mice shows that endothelial-derived cells are normal, whereas neural crest-derived cells are abnormally increased in number and misplaced in the valve leaflets. In contrast, genetic ablation of Krox20 -expressing cells is not sufficient to cause an aortic valve defect, suggesting that adjacent cells can compensate this depletion. Our findings demonstrate a crucial role for Krox20 in arterial valve development and reveal that an excess of neural crest cells may be associated with bicuspid aortic valve. © 2018. Published by The Company of Biologists Ltd.

  4. Towards better GHG emissions savings with use of ISO GHG standards

    International Nuclear Information System (INIS)

    Chan Kook Weng

    2010-01-01

    The 15th Conference of Parties (COP 15) at Copenhagen, Denmark in December 2009 highlighted the need to combat climate change by facing the challenge of committing to reducing our emissions at all three levels with locally appropriate mitigation actions (LAMAs) at the local level to be linked to the nationally appropriate mitigation actions (NAMAs) and then contribute onwards to globally appropriate mitigation actions (GAMAs). The aim is to find solutions for both adaptation and mitigation by ensuring sufficient means are made available to support such efforts. This is because the world in entering a new phase that will be characterised by green growth in business. Thus be it agriculture that uses local knowledge of specific crop and livestock varieties to help in secure food supply, bio-energy, transport, industries, there must be policies to understand ecosystem-based to link people, biodiversity, energy, water and carbon so as to be more resilient and adaptable to the need for a low carbon economy in todays society.Climate change therefore affects organisations in many areas and they include legal compliance, carbon market, corporate social responsibility and sustainable development. Promoting sustainability requires making efficient use of energy, water and natural resources, decrease in waste load through recycling and streamlining the processes leading to everything that decreases their CO 2 and water footprints. Currently there are many GHG schemes and programmes and the issues centres around compatibility, costs and most importantly credibility. Achieving real GHG emissions reduction requires controlled and verified emissions reductions and quantification that are sound and verifiable. Thanks to the development of the ISO suite of standards on GHG and related matters, the use of these harmonised standards has given the assurance that a tonne of carbon is a tonne of carbon be it in Malaysia, Mali or Mongolia.The use of these standards like ISO 14064 Part 1

  5. Missed aortic valve endocarditis resulting in complete atrioventricular block and redo mechanical valve replacement.

    Science.gov (United States)

    Harky, Amer; Garner, Megan; Popa, Miruna; Shipolini, Alex

    2017-08-03

    Infective endocarditis is a rare disease associated with high morbidity and mortality. As a result, early diagnosis and prompt antibiotic treatment with or without surgical intervention is crucial in the management of such condition.We report a case of missed infective endocarditis of the aortic valve. The patient underwent mechanical aortic valve replacement, with the native valve being sent for histopathological examination. On re-admission 16 months later, he presented with syncope, shortness of breathing and complete heart block. On review of the histopathology of native aortic valve, endocarditis was identified which had not been acted on. The patient underwent redo aortic valve replacement for severe aortic regurgitation.We highlight the importance of following up histopathological results as well as the need for multidisciplinary treatment of endocarditis with a combination of surgical and antibiotic therapy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Improved corrosion resistance of spin-valve film

    International Nuclear Information System (INIS)

    Tetsukawa, H.; Hommura, H.; Okabe, A.; Soda, Y.

    2007-01-01

    We investigated the corrosion behavior and magnetoresistance of spin-valve film in order to improve the corrosion resistance of the spin-valve head for a tape recording system. The conventional spin-valve head (sub./Ta/NiFe/CoFe/Cu/CoFe/PtMn/Ta) with no diamond-like carbon (DLC) protective layer showed poor corrosion resistance. This is because the CoFe for ferromagnetic layer and Cu for spacer in the spin-valve film exhibited poor corrosion resistance. The corrosion resistance of the CoFe film and Cu film improved with the addition of Ni and Au, respectively. The spin-valve film (sub./Ta/NiFe/CoNiFe/CuAu/CoNiFe/PtMn/Ta) showed higher pitting potential than the conventional spin-valve film by +0.45 V. This presents a significant improvement over the conventional spin-valve film. We also investigated the effect of the composition of ferromagnetic layer and spacer on the magnetoresistance of the spin-valve film. The magnetoresistance of the spin-valve film by substitution of CoNiFe for CoFe in ferromagnetic layer decreased slightly. The magnetoresistance of the spin-valve film decreased as the addition of Au of the spacer increased. The diffusion at CoNiFe/CuAu interface has not been observed in annealing process. The quantitative relation between corrosion resistance and magnetoresistance of spin-valve film, and its ferromagnetic layer and spacer's compositions have been clarified. The output voltage at 50 Oe of the corrosion-resistant spin-valve head with CoNiFe ferromagnetic layer and CuAu spacer was about 50% of that of the conventional spin-valve head

  7. Improved corrosion resistance of spin-valve film

    Energy Technology Data Exchange (ETDEWEB)

    Tetsukawa, H. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)]. E-mail: tetsukaw@arc.sony.co.jp; Hommura, H. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan); Okabe, A. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan); Soda, Y. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)

    2007-06-15

    We investigated the corrosion behavior and magnetoresistance of spin-valve film in order to improve the corrosion resistance of the spin-valve head for a tape recording system. The conventional spin-valve head (sub./Ta/NiFe/CoFe/Cu/CoFe/PtMn/Ta) with no diamond-like carbon (DLC) protective layer showed poor corrosion resistance. This is because the CoFe for ferromagnetic layer and Cu for spacer in the spin-valve film exhibited poor corrosion resistance. The corrosion resistance of the CoFe film and Cu film improved with the addition of Ni and Au, respectively. The spin-valve film (sub./Ta/NiFe/CoNiFe/CuAu/CoNiFe/PtMn/Ta) showed higher pitting potential than the conventional spin-valve film by +0.45 V. This presents a significant improvement over the conventional spin-valve film. We also investigated the effect of the composition of ferromagnetic layer and spacer on the magnetoresistance of the spin-valve film. The magnetoresistance of the spin-valve film by substitution of CoNiFe for CoFe in ferromagnetic layer decreased slightly. The magnetoresistance of the spin-valve film decreased as the addition of Au of the spacer increased. The diffusion at CoNiFe/CuAu interface has not been observed in annealing process. The quantitative relation between corrosion resistance and magnetoresistance of spin-valve film, and its ferromagnetic layer and spacer's compositions have been clarified. The output voltage at 50 Oe of the corrosion-resistant spin-valve head with CoNiFe ferromagnetic layer and CuAu spacer was about 50% of that of the conventional spin-valve head.

  8. [Tricuspid valve insufficiency: what should be done?].

    Science.gov (United States)

    von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G

    1998-12-01

    Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.

  9. Evaluating Education Quality in Terms of ISO9000 Standards

    Science.gov (United States)

    Fengchun, Cheng; Vogel, Linda R.; Zhaoyu, Zheng

    2014-01-01

    While nations measure the quality of educational systems by different standards, many nations, such as China, have adopted the ISO9000 quality standards to assess the quality of schools. This article explores the various elements of the the ISO9000 standards and how each element relates to the various groups that are consumers or stakeholders in…

  10. Mitral valve surgery - open

    Science.gov (United States)

    ... Taking warfarin (Coumadin) References Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Mitral Valve Prolapse Read more A. ...

  11. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  12. Establishing an ISO 10001-based promise in inpatients care.

    Science.gov (United States)

    Khan, Mohammad Ashiqur Rahman; Karapetrovic, Stanislav

    2015-01-01

    The purpose of this paper is to explore ISO 10001:2007 in planning, designing and developing a customer satisfaction promise (CSP) intended for inpatients care. Through meetings and interviews with research participants, who included a program manager, unit managers and registered nurses, information about potential promises and their implementation was obtained and analyzed. A number of promises were drafted and one was finally selected to be developed as a CSP. Applying the standard required adaptation and novel interpretation. Additionally, ISO 10002:2004 (Clause 7) was used to design the feedback handling activities. A promise initially chosen for development turned out to be difficult to implement, experience that helped in selecting and developing the final promise. Research participants found the ISO 10001-based method useful and comprehensible. This paper presents a specific health care example of how to adapt a standard's guideline in establishing customer promises. The authors show how a promise can be used in alleviating an existing issue (i.e. communication between carers and patients). The learning can be beneficial in various health care settings. To the knowledge, this paper shows the first example of applying ISO 10001:2007 in a health care case. A few activities suggested by the standard are further detailed, and a new activity is introduced. The integrated use of ISO 10001:2007 and 10002:2004 is presented and how one can be "augmented" by the other is demonstrated.

  13. Correspondence of ISO 9001:2008 with IAEA GS-R-3

    International Nuclear Information System (INIS)

    Kibrit, Eduardo

    2009-01-01

    This article identifies, characterises and analyses International Organisation for Standardisation (ISO) and International Atomic Energy Agency (IAEA) normative requirements for the development and implementation of quality management systems in nuclear organisations. The structures of the applicable standards, ISO 9001:2008 and IAEA GS-R-3, are characterised. The differences and similarities of objective, focus, scope, level of application, structure, vocabulary, management system, management responsibility, resource management, process implementation, measurement, assessment and improvement verified in the applicable standards are deeply reviewed. A correspondence of the applicable standards' requirements is presented topic by topic. A correlation of the applicable standards' requirements is made, showing IAEA GS-R-3 topics that have no correlation with ISO 9001:2008 and ISO 9001:2008 topics that have no correlation with IAEA GS-R-3. Conclusive remarks advise the pros and cons of using one of the applicable standards or the other. (author)

  14. Corrosion of valve metals

    International Nuclear Information System (INIS)

    Draley, J.E.

    1976-01-01

    A general survey related to the corrosion of valve metals or film-forming metals. The way these metals corrode with some general examples is described. Valve metals form relatively perfect oxide films with little breakdown or leakage when anodized

  15. Echocardiographic Assessment of Heart Valve Prostheses

    Science.gov (United States)

    Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio

    2014-01-01

    Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917

  16. 3D Printed Multimaterial Microfluidic Valve.

    Directory of Open Access Journals (Sweden)

    Steven J Keating

    Full Text Available We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  17. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  18. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  19. All in the family: matrimonial mitral valve clicks.

    Science.gov (United States)

    Desser, K B; Bokhari, S I; Benchimol, A; Romney, D

    1981-05-01

    Mitral valve clicks with or without late systolic murmurs were detected in genetically unrelated marital partners of 5 families. The first family represented 2 successive nonconsanguineous marital unions with 3 generations of mitral valve clicks. The second family included 1 natural and 2 adopted children with clinical and echographic evidence of mitral valve prolapse. The third family was comprised of asymptomatic parents, both with nonejection clicks and mitral valve prolapse, whose daughter presented 3 years previously with syncope, palpitations, and combined mitral and tricuspid valve prolapse. The fourth family had 3 members with auscultatory and ultrasonic manifestations of billowing mitral valve, whereas the fourth member had "silent mitral valve prolapse." The fifth family represented a mother with auscultatory and echographic evidence of mitral valve prolapse; her 14-year-old daughter had both mitral and tricuspid valve prolapse, whereas the son had a bicuspid aortic valve. Both children were products of a prior marriage, and her husband has symptomatic mitral valve prolapse. We conclude that matrimonial mitral valve prolapse probably reflects the purported (6--10%) prevalence of this disorder in the general population. The consequences of such marital union on progeny is currently unclear and warrants future investigation.

  20. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    Science.gov (United States)

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  1. ISO 9000 IMPLEMENTATION AND PERCEIVED ORGANISATIONAL OUTCOME: THE CASE OF A SERVICE ORGANISATION

    Directory of Open Access Journals (Sweden)

    Jasni Abdul Latif

    2003-01-01

    Full Text Available The study examines the relationship between the perceptions of the employees about ISO 9000 implementation and perceived organisational outcomes. A conceptual framework linking the level of employee influence and involvement, their perception of ISO 9000 and the perceived impact on their work and the organisational outcomes is posited. Data was collected from a random sample of 64 employees of a service organisation. Contrary to expectations, the work impact of ISO 9000 was not correlated with the efficiency and market outcomes of ISO 9000 certification but the employee involvement, influence and perception of ISO 9000 were. The conceptualization of the influence path of ISO 9000 implementation on the organisational outcomes may require rethinking as perception may have a direct effect on the outcomes without the mediation of the impact on work. In short, employees may report benefits or positive outcomes even though no change is reported in their work.

  2. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  3. High-risk Trans-Catheter Aortic Valve Replacement in a Failed Freestyle Valve with Low Coronary Height: A Case Report.

    Science.gov (United States)

    Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A

    2017-06-01

    A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.

  4. Aortic Volumetry at Contrast-Enhanced Magnetic Resonance Angiography: Feasibility as a Sensitive Method for Monitoring Bicuspid Aortic Valve Aortopathy.

    Science.gov (United States)

    Trinh, Brian; Dubin, Iram; Rahman, Ozair; Ferreira Botelho, Marcos P; Naro, Nicholas; Carr, James C; Collins, Jeremy D; Barker, Alex J

    2017-04-01

    Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth. A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P volumetry. Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.

  5. Comparison of 3D Echocardiogram-Derived 3D Printed Valve Models to Molded Models for Simulated Repair of Pediatric Atrioventricular Valves.

    Science.gov (United States)

    Scanlan, Adam B; Nguyen, Alex V; Ilina, Anna; Lasso, Andras; Cripe, Linnea; Jegatheeswaran, Anusha; Silvestro, Elizabeth; McGowan, Francis X; Mascio, Christopher E; Fuller, Stephanie; Spray, Thomas L; Cohen, Meryl S; Fichtinger, Gabor; Jolley, Matthew A

    2018-03-01

    Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.

  6. [Pannus Formation Six-years after Aortic and Mitral Valve Replacement with Tissue Valves;Report of a Case].

    Science.gov (United States)

    Nakamura, Makoto; Muraoka, Arata; Aizawa, Kei; Akutsu, Hirohiko; Kurumisawa, Soki; Misawa, Yoshio

    2015-07-01

    A 77-year-old man presented with exertional dyspnea. He had undergone aortic and mitral valve replacement with tissue valves 6-years earlier. The patient's hemoglobin level was 9.8 g/dl and serum aspartate aminotransferase (70 mU/ml) and lactate dehydrogenase (1,112 mU/ml) were elevated. Echocardiography revealed stenosis of the prosthetic valve in the aortic position with peak flow velocity of 3.8 m/second and massive mitral regurgitation. The patient underwent repeat valve replacement. Pannus formation around both implanted valves was observed. The aortic valve orifice was narrowed by the pannus, and one cusp of the prosthesis in the mitral position was fixed and caused the regurgitation, but they were free from cusp laceration or calcification. The patient's postoperative course was uneventful, and he continues to do well 14 months after surgery.

  7. ISO 14000 and the nuclear licensing

    International Nuclear Information System (INIS)

    Martins, Nadia Soido Falcao

    1999-01-01

    As concern grows for maintaining and improving the quality of the environment and protecting human health, all the world is turning its attention to the potential environmental in pact of their industrial activities. One of the most important contribution in that way is the International Standard ISO 14000 series. In the utilization of nuclear energy, right from the inception, the safety of personnel, environment and the population has been the basic consideration. Over the years well established licenses criteria have been proposed to limit and control the environmental impact of the plant operation and emergencies situation. In this paper are discussed some specific requirements for implementation of the environmental management system specified by ISO 14000 compared to the environmental requirements for nuclear licensing. (author)

  8. Definition of a CDI metadata profile and its ISO 19139 based encoding

    Science.gov (United States)

    Boldrini, Enrico; de Korte, Arjen; Santoro, Mattia; Schaap, Dick M. A.; Nativi, Stefano; Manzella, Giuseppe

    2010-05-01

    The Common Data Index (CDI) is the middleware service adopted by SeaDataNet for discovery and query. The primary goal of the EU funded project SeaDataNet is to develop a system which provides transparent access to marine data sets and data products from 36 countries in and around Europe. The European context of SeaDataNet requires that the developed system complies with European Directive INSPIRE. In order to assure the required conformity a GI-cat based solution is proposed. GI-cat is a broker service able to mediate from different metadata sources and publish them through a consistent and unified interface. In this case GI-cat is used as a front end to the SeaDataNet portal publishing the original data, based on CDI v.1 XML schema, through an ISO 19139 application profile catalog interface (OGC CSW AP ISO). The choice of ISO 19139 is supported and driven by INSPIRE Implementing Rules, that have been used as a reference through the whole development process. A mapping from the CDI data model to the ISO 19139 was hence to be implemented in GI-cat and a first draft quickly developed, as both CDI v.1 and ISO 19139 happen to be XML implementations based on the same abstract data model (standard ISO 19115 - metadata about geographic information). This first draft mapping pointed out the CDI metadata model differences with respect to ISO 19115, as it was not possible to accommodate all the information contained in CDI v.1 into ISO 19139. Moreover some modifications were needed in order to reach INSPIRE compliance. The consequent work consisted in the definition of the CDI metadata model as a profile of ISO 19115. This included checking of all the metadata elements present in CDI and their cardinality. A comparison was made with respect to ISO 19115 and possible extensions were individuated. ISO 19139 was then chosen as a natural XML implementation of this new CDI metadata profile. The mapping and the profile definition processes were iteratively refined leading up to a

  9. BiBTeX styl pro ČSN ISO 690 a ČSN ISO 690-2

    OpenAIRE

    Pyšný, Radek

    2009-01-01

    Tato práce popisuje průběh vytváření bibliografického stylu pro nástroj BibTeX, pomocí něhož lze v LaTeXu sázet bibliografické citace v souladu s normou ČSN ISO 690. V úvodu práce je proveden rozbor ČSN ISO 690. Následuje popis spolupráce mezi systémem LaTeX a nástrojem BibTeX. Podstatná část práce je věnována popisu struktury souborů, které BibTeX potřebuje pro svou funkci, tj. bibliografická databáze a bibliografický styl. Závěr této práce je věnovaný popisu vlastností vytvořeného bibliogra...

  10. Safety valve opening and closing operation monitor

    International Nuclear Information System (INIS)

    Kodama, Kunio; Takeshima, Ikuo; Takahashi, Kiyokazu.

    1981-01-01

    Purpose: To enable the detection of the closing of a safety valve when the internal pressure in a BWR type reactor is a value which will close the safety valve, by inputting signals from a pressure detecting device mounted directly at a reactor vessel and a safety valve discharge pressure detecting device to an AND logic circuit. Constitution: A safety valve monitor is formed of a pressure switch mounted at a reactor pressure vessel, a pressure switch mounted at the exhaust pipe of the escape safety valve and a logic circuit and the lide. When the input pressure of the safety valve is raised so that the valve and the pressure switch mounted at the exhaust pipe are operated, an alarm is indicated, and the operation of the pressure switch mounted at a pressure vessel is eliminated. If the safety valve is not reclosed when the vessel pressure is decreased lower than the pressure at which it is to be reclosed after the safety valve is operated, an alarm is generated by the logic circuit since both the pressure switches are operated. (Sekiya, K.)

  11. [ISO 9001-2000 certification for refractive laser treatment].

    Science.gov (United States)

    Lebuisson, D A; Arson, B; Abenhaïm, A; Albou-Ganem, C; Assouline, M; Chong Sit, D; Danan, A; Montefiore, G; Montin, J-F; Nguyen-Khoa, J-L; Pietrini, D; Saragoussi, J-J; Trong, Th; Amar, R

    2005-05-01

    To obtain ISO 9001-2000 certification for laser corneal refractive treatment, never before sought in Europe. The consulting firm Veritas led the certification process with the clinic's staff manager. This ISO norm is dedicated to the implementation of a quality management system. We assessed and optimized all necessary resources, evaluating customer satisfaction using patient and referring-physician surveys. We started quality rounds including surgeons, nurses, and technicians. Based on this preparation, we redefined and explained all processes including staff responsibilities and necessary resources in the quality manual. The procedure lasted 14 months with substantial involvement on the part of the management. Unconditional ISO 9001-2000 certification was granted by the independent audit firm, BVQI, in december 2003 for refractive laser treatment. The 2000 version of the new ISO 9001-2000 seeks to meet the demand for improving health care delivery in this field, most particularly by establishing a clear procedural orientation. Such certification enhances team work, stabilizes methodologies, and reinforces cohesion and self-audit. Patients notice that the center follows a consistent quality policy and are assured that the clinic respects rules and regulations. Certification is an advantageous alternative when accreditation cannot be considered. Our article discusses the steps taken in upper management, quality management, procedural guidance, as well as customer and staff counselling. It also discusses the project's cost/benefit ratio for the organization.

  12. Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: a study of multiple valve implants in the U.S. PARTNER trial (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve).

    Science.gov (United States)

    Makkar, Raj R; Jilaihawi, Hasan; Chakravarty, Tarun; Fontana, Gregory P; Kapadia, Samir; Babaliaros, Vasilis; Cheng, Wen; Thourani, Vinod H; Bavaria, Joseph; Svensson, Lars; Kodali, Susheel; Shiota, Takahiro; Siegel, Robert; Tuzcu, E Murat; Xu, Ke; Hahn, Rebecca T; Herrmann, Howard C; Reisman, Mark; Whisenant, Brian; Lim, Scott; Beohar, Nirat; Mack, Michael; Teirstein, Paul; Rihal, Charanjit; Douglas, Pamela S; Blackstone, Eugene; Pichard, Augusto; Webb, John G; Leon, Martin B

    2013-07-30

    This study investigated the determinants and outcomes of acute insertion of a second transcatheter prosthetic valve (TV) within the first (TV-in-TV) or transcatheter valve embolization (TVE) after transcatheter aortic valve replacement (TAVR). TAVR failure can occur with both TV-in-TV and TVE as a consequence of TAVR malpositioning. Only case reports and limited series pertaining to these complications have been reported to date. Patients undergoing TAVR in the PARTNER (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve) randomized trial (cohorts A and B) and accompanying registries were studied. Data were dichotomized for those with and without TV-in-TV or TVE, respectively. From a total of 2,554 consecutive patients, 63 (2.47%) underwent TV-in-TV and 26 (1.01%) TVE. The indication for TV-in-TV was significant aortic regurgitation in most patients, often due not only to malpositioning but also to leaflet dysfunction. Despite similar aortic valve function on follow-up echoes, TV-in-TV was an independent predictor of 1-year cardiovascular mortality (hazard ratio [HR]: 1.86, 95% confidence interval [CI]: 1.03 to 3.38, p = 0.041), with a nonsignificant trend toward greater all-cause mortality (HR: 1.43, 95% CI: 0.88 to 2.33, p = 0.15). Technical and anatomical reasons accounted for most cases of TVE. A multivariable analysis found TVE to be an independent predictor of 1-year mortality (HR: 2.68, 95% CI: 1.34 to 5.36, p = 0.0055) but not cardiovascular mortality (HR: 1.30, 95% CI: 0.48 to 3.52, p = 0.60). Acute TV-in-TV and TVE are serious sequelae of TAVR, often resulting in multiple valve implants. They carry an excess of mortality and are caused by anatomic and technical factors, which may be avoidable with judicious procedural planning. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Performance of balanced bellows safety relief valves

    International Nuclear Information System (INIS)

    Lai, Y.S.

    1992-01-01

    By the nature of its design, the set point and lift of a conventional spring loaded safety relief valve are sensitive to back pressure. One way to reduce the adverse effects of the back pressure on the safety relief valve function is to install a balanced bellows in a safety relief valve. The metallic bellows has a rather wide range of manufacturing tolerance which makes the design of the bellows safety relief valve very complicated. The state-of-the-art balanced bellows safety relief valve can only substantially minimize, but cannot totally eliminate the back pressure effects on its set point and relieving capacity. Set point change is a linear function of the back pressure to the set pressure ratio. Depending on the valve design, the set point correction factor can be either greater or smaller than unity. There exists an allowable back pressure and critical back pressure for each safety relief valve. When total back pressure exceeds the R a , the relieving capacity will be reduced mainly resulting from the valve lift being reduced by the back pressure and the capacity reduction factor should be applied in valve sizing. Once the R c is exceeded, the safety relief valve becomes unstable and loses its over pressure protection capability. The capacity reduction factor is a function of system overpressure, but their relationship is non-linear in nature. (orig.)

  14. Hydraulic engine valve actuation system including independent feedback control

    Science.gov (United States)

    Marriott, Craig D

    2013-06-04

    A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

  15. Implante valve-in-valve transcateter em posição aórtica: uma mudança de seleção? Transcatheter aortic valve-in-valve implantation: a selection change?

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2012-09-01

    Full Text Available INTRODUÇÃO: A reoperação para substituição de biopróteses aórticas com disfunção é procedimento que envolve considerável risco. Em alguns casos, a mortalidade é elevada e pode contraindicar o procedimento. O implante minimamente invasivo "valve-in-valve" transcateter de valva aórtica parece ser uma alternativa, reduzindo morbimortalidade. O objetivo deste estudo foi avaliar esses implantes utilizando a prótese Braile Inovare. MÉTODOS: A prótese Braile Inovare, transcateter, balão expansível foi utilizada em 14 casos. Euroscore médio foi de 42,9%. Todos os pacientes eram portadores de dupla disfunção de bioprótese aórtica. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Por meio de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência. Foram realizados controles clínicos e ecocardiográficos seriados. O seguimento variou de 1 a 30 meses. RESULTADOS: A correta liberação protética foi possível em todos os casos. Não ocorreu conversão. Não houve mortalidade operatória. A mortalidade em 30 dias foi de 14,3% (dois casos. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório e o gradiente aórtico apresentou redução significativa. A insuficiência aórtica residual não esteve presente. Não ocorreu complicação vascular periférica ou bloqueio atrioventricular total. CONCLUSÕES: O implante "valve-in-valve" de valva aórtica transcateter em biopróteses com disfunção é um procedimento seguro e com morbimortalidade baixa. Essa possibilidade poderá alterar a indicação de seleção de prótese no procedimento inicial, favorecendo próteses biológicas.OBJECTIVE: Aortic valve replacement for bioprosthesis dysfunction is a procedure involving considerable risk. In some cases, mortality is high and may contraindicate the procedure

  16. Framework for establishing records control in hospitals as an ISO 9001 requirement.

    Science.gov (United States)

    Al-Qatawneh, Lina

    2017-02-13

    Purpose The purpose of this paper is to present the process followed to control records in a Jordanian private community hospital as an ISO 9001:2008 standard requirement. Design/methodology/approach Under the hospital quality council's supervision, the quality management and development office staff were responsible for designing, planning and implementing the quality management system (QMS) using the ISO 9001:2008 standard. A policy for records control was established. An action plan for establishing the records control was developed and implemented. On completion, a coding system for records was specified to be used by hospital staff. Finally, an internal audit was performed to verify conformity to the ISO 9001:2008 standard requirements. Findings Successful certification by a neutral body ascertained that the hospital's QMS conformed to the ISO 9001:2008 requirements. A framework was developed that describes the records controlling process, which can be used by staff in any healthcare organization wanting to achieve ISO 9001:2008 accreditation. Originality/value Given the increased interest among healthcare organizations to achieve the ISO 9001 certification, the proposed framework for establishing records control is developed and is expected to be a valuable management tool to improve and sustain healthcare quality.

  17. [Ahmed valve in glaucoma surgery].

    Science.gov (United States)

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  18. Vocational High School Effectiveness Standard ISO 9001: 2008 for Achievement Content Standards, Standard Process and Competency Standards Graduates

    Directory of Open Access Journals (Sweden)

    Yeni Ratih Pratiwi

    2014-06-01

    Full Text Available Efektivitas Sekolah Menengah Kejuruan Berstandar ISO 9001:2008 terhadap Pencapaian Standar Isi, Standar Proses dan Standar Kompetensi Lulusan Abstract: The purpose of this study was to determine differences in the effectiveness of the achievement of the content standards, process standards, and competency standards in vocational already standard ISO 9001: 2008 with CMS that has not been standardized ISO 9001: 2008 both in public schools and private schools. Data collection using the questionnaire enclosed Likert scale models. Analysis of data using one-way ANOVA using SPSS. The results showed: (1 there is no difference in effectiveness between public SMK ISO standard ISO standards with private SMK (P = 0.001; (2 there are differences in the effectiveness of public SMK SMK ISO standards with ISO standards have not (P = 0.000; (3 there are differences in the effectiveness of public SMK ISO standards with private vocational yet ISO standards (P = 0.000; (4 there are differences in the effectiveness of the private vocational school with vocational standard ISO standard ISO country has not (P = 0.015; (5 there are differences in the effectiveness of the private vocational bertandar ISO with private vocational yet standardized ISO (P = 0.000; (6 there was no difference in the effectiveness of public SMK has not been standardized by the ISO standard ISO private SMK yet. Key Words: vocational high school standards ISO 9001: 2008, the standard content, process standards, competency standards Abstrak: Tujuan penelitian ini untuk mengetahui perbedaan efektivitas pencapaian standar isi, standar proses, dan standar kompetensi lulusan pada SMK yang sudah berstandar ISO 9001:2008 dengan SMK yang belum berstandar ISO 9001:2008 baik pada sekolah negeri maupun sekolah swasta. Pengumpulan data menggunakan kuisioner tertutup model skala likert. Analisis data menggunakan ANOVA one way menggunakan program SPSS. Hasil penelitian menunjukkan: (1 ada perbedaan

  19. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  20. Analysis of ISO 26262 Compliant Techniques for the Automotive Domain

    NARCIS (Netherlands)

    M. S. Kannan; Y. Dajsuren (Yanjindulam); Y. Luo; I. Barosan

    2015-01-01

    htmlabstractThe ISO 26262 standard denes functional safety for automotive E/E systems. Since the publication of the rst edition of this standard in 2011, many dierent safety techniques complying to the ISO 26262 have been developed. However, it is not clear which parts and (sub-) phases of the

  1. Analysis of ISO 26262 compliant techniques for the automotive domain

    NARCIS (Netherlands)

    S., Manoj Kannan; Dajsuren, Y.; Luo, Y.; Barosan, I.; Antkiewicz, M.; Atlee, J.; Dingel, J.; S, R.

    2015-01-01

    The ISO 26262 standard defines functional safety for automotive E/E systems. Since the publication of the first edition of this standard in 2011, many different safety techniques complying to the ISO 26262 have been developed. However, it is not clear which parts and (sub-) phases of the standard

  2. Bicuspid aortic valves: Diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, David J., E-mail: david.murphy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); McEvoy, Sinead H., E-mail: s.mcevoy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); Iyengar, Sri, E-mail: sri.iyengar@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Feuchtner, Gudrun, E-mail: Gudrun.Feuchtner@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck (Austria); Cury, Ricardo C., E-mail: r.cury@baptisthealth.net [Department of Radiology, Baptist Cardiac and Vascular Institute, 8900 North Kendall Drive, Miami, FL 33176 (United States); Roobottom, Carl, E-mail: carl.roobottom@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Plymouth University Peninsula Schools of Medicine and Dentistry (United Kingdom); Baumueller, Stephan, E-mail: Hatem.Alkadhi@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Alkadhi, Hatem, E-mail: stephan.baumueller@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Dodd, Jonathan D., E-mail: jonniedodd@gmail.com [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland)

    2014-08-15

    Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥3.8 cm{sup 2}, 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54–1.0), 100%, 100% and 70% respectively. Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT

  3. Diagnóstico da integração dos sistemas de gestão ISO 9001, ISO 14001 e OHSAS 18001

    Directory of Open Access Journals (Sweden)

    Samuel Vinícius Bonato

    2015-09-01

    Full Text Available Este artigo apresenta os resultados de uma pesquisa que teve por finalidade o diagnóstico do nível de integração de sistemas de gestão baseados nas normas ISO 9001, ISO 14001 e OHSAS 18001 em empresas do ramo metal-mecânico. Inicialmente foi descrito o método de diagnóstico e posteriormente realizada a sua aplicação em uma empresa já certificada nas três normas, mas que possui dois sistemas de gestão distintos: o Sistema de Gestão da Qualidade (SGQ baseado na norma ISO 9001 e o Sistema de Gestão de Saúde, Segurança e Meio Ambiente (SSM baseado nas normas ISO 14001 e OHSAS 18001. Entre os principais resultados, destaca-se a aceitação favorável do diagnóstico da integração na empresa estudada. Com a realização do diagnóstico, verificou-se que a organização não atende totalmente a integração de nenhum dos requisitos avaliados. Foram sugeridas oportunidades de melhoria para integração dos requisitos normativos comuns, reduzindo custos e recursos para manutenção do sistema de gestão da empresa.

  4. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  5. Discussion on the compilation of document of iso quality management system for radiation sterilization enterprises

    International Nuclear Information System (INIS)

    Li Chunhong; Ha Yiming; Zhou Hongjie; Feng Zhiguo; Wang Feng

    2006-01-01

    According to the character of cooperation of radiation sterilization, and association with request of ISO9001, ISO13485 and ISO11137, compilation of document in quality manual, procedure document and technological document during certification of ISO quality management system of cooperation of radiation sterilization was discussed. (authors)

  6. Interim Report on ISO TC 163 Working Group 3. Annual progress report

    Energy Technology Data Exchange (ETDEWEB)

    Fairey, Philip [Florida Solar Energy Center, Cocoa, FL (United States)

    2009-04-02

    This reports cover the initial year efforts of the International Standards Organization (ISO) to develop international standards for rating the energy performance of buildings. The author of this report is a participant in this effort. This report summarizes the activities of the ISO Working Group charged with development of these standards and makes recommendations to the sponsors for future U.S. involvement in this ISO effort.

  7. Progress report on the management of the NEA ISOE system

    Energy Technology Data Exchange (ETDEWEB)

    Lazo, E. [OECD Nuclear Energy Agency, Issy-les-Moulineaux (France)

    1995-03-01

    The Information System on Occupational Exposure (ISOE) was launched by the Organization for Economic Cooperation and Development (OECD), Nuclear Energy Agency (NEA) on 1 January, 1992, to facilitate the communication of dosimetric and ALARA implementation data among nuclear utilities around the world. After two years of operation the System has become a mature interactive network for transfer of data and experience. Currently, 37 utilities from 12 countries, representing 289 power plants, and 12 national regulatory authorities participate in ISOE. Agreements for cooperation also exist between the NEA and the Commission of the European Communities (CEC), and the Paris Center of the WOrld Association of Nuclear Operators (WANO-PC). In addition, the International Atomic Energy Agency (IAEA) is acting as a co-sponsor of ISOE for the participation of non-NEA member countries. Three Regional Technical Centres, Europe, Asia, and Non-NEA member countries, serve to administer the system. The ISOE Network is comprised of three data bases and a communications network at several levels. The three ISOE data bases include the following types of information: NEA1 - annual plant dosimetric information; NEA2 - plant operational characteristics for dose and dose rate reduction; and NEA3 - job specific ALARA practices and experiences. The ISOE communications network has matured greatly during 1992 and 1993. In addition to having access to the above mentioned data bases, participants may now solicit information on new subjects, through the Technical Centres, from all other participants on a real-time basis. Information Sheets on these studies are produced for distribution to all participants. In addition, Topical Reports on areas of interest are produced, and Topical Meetings are held annually.

  8. Progress report on the management of the NEA ISOE system

    International Nuclear Information System (INIS)

    Lazo, E.

    1995-01-01

    The Information System on Occupational Exposure (ISOE) was launched by the Organization for Economic Cooperation and Development (OECD), Nuclear Energy Agency (NEA) on 1 January, 1992, to facilitate the communication of dosimetric and ALARA implementation data among nuclear utilities around the world. After two years of operation the System has become a mature interactive network for transfer of data and experience. Currently, 37 utilities from 12 countries, representing 289 power plants, and 12 national regulatory authorities participate in ISOE. Agreements for cooperation also exist between the NEA and the Commission of the European Communities (CEC), and the Paris Center of the WOrld Association of Nuclear Operators (WANO-PC). In addition, the International Atomic Energy Agency (IAEA) is acting as a co-sponsor of ISOE for the participation of non-NEA member countries. Three Regional Technical Centres, Europe, Asia, and Non-NEA member countries, serve to administer the system. The ISOE Network is comprised of three data bases and a communications network at several levels. The three ISOE data bases include the following types of information: NEA1 - annual plant dosimetric information; NEA2 - plant operational characteristics for dose and dose rate reduction; and NEA3 - job specific ALARA practices and experiences. The ISOE communications network has matured greatly during 1992 and 1993. In addition to having access to the above mentioned data bases, participants may now solicit information on new subjects, through the Technical Centres, from all other participants on a real-time basis. Information Sheets on these studies are produced for distribution to all participants. In addition, Topical Reports on areas of interest are produced, and Topical Meetings are held annually

  9. ISO standardization in nuclear technology

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D. (Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia)); Cermak, O. (Urad pro Normalizaci a Mereni, Prague (Czechoslovakia))

    1984-10-01

    The activity is described of the technical commission ISO/TC 85 which is currently divided into 4 subcommissions (SC) and 24 working groups. SC 1 ''Terminology, definitions, units, abbreviations'' has one working group. The most important document of this SC is ISO 921-1972 (Dictionary of nuclear technology). SC 2 ''Radiation protection'' has 9 working groups and has processed standards in dosimetry. SC 3 ''Technology of power reactors'' has 6 working groups and its work is related to IAEA activities within the NUSS program. SC 4 ''Technology of nuclear fuels'' has 8 working groups. SC 4 has compiled the basic standards for sealed sources and methods of testing their tightness. The results of the work of this group have been reflected into the standardization work of CMEA. A list is given of published international standards within TC 85.

  10. MEMS Micro-Valve for Space Applications

    Science.gov (United States)

    Chakraborty, I.; Tang, W. C.; Bame, D. P.; Tang, T. K.

    1998-01-01

    We report on the development of a Micro-ElectroMechanical Systems (MEMS) valve that is designed to meet the rigorous performance requirements for a variety of space applications, such as micropropulsion, in-situ chemical analysis of other planets, or micro-fluidics experiments in micro-gravity. These systems often require very small yet reliable silicon valves with extremely low leak rates and long shelf lives. Also, they must survive the perils of space travel, which include unstoppable radiation, monumental shock and vibration forces, as well as extreme variations in temperature. Currently, no commercial MEMS valve meets these requirements. We at JPL are developing a piezoelectric MEMS valve that attempts to address the unique problem of space. We begin with proven configurations that may seem familiar. However, we have implemented some major design innovations that should produce a superior valve. The JPL micro-valve is expected to have an extremely low leak rate, limited susceptibility to particulates, vibration or radiation, as well as a wide operational temperature range.

  11. IMPLEMENTASI ISO 9001: 2000 PADA PEMBELAJARAN PRODUKTIF BIDANG KEAHLIAN BANGUNAN DI SEKOLAH MENENGAH KEJURUAN

    Directory of Open Access Journals (Sweden)

    Riban Riban

    2012-08-01

    Full Text Available The implementation of ISO 9001: 2000 in productive learning of building engineering sector in vocational education. The objtective of this study was to uncover the barriers to implementation of ISO 9001:2000 in productive learning. The study was designed using multisite study design. Tecniques of collecting the data were interview, observation to partici­pants, and documentation test. The result of the study are: (1 Implementation of the ISO 9001: 2000 in productive learning of  building engineering sector relates to the implementation of the concept of P-D-C-A in the ISO quality management system; (2 the barriers in implementation of ISO 9001:2000 in pro­ductive learning include low awareness level, inconsistencies, and disobedience; and (3 efforts to overcome the barriers to implementation of ISO 9001:2000 in produc­tive learning involve building the shared commitment, socialization in order to create together awareness, supervising, and doing the preventive action. Implementasi ISO 9001: 2000 pada Pembelajaran Produktif Bidang Keahlian Bangunan di Sekolah Menengah Kejuruan. Penelitian ini bermaksud meng­ungkap lebih mendalam tentang, imple­men­­­tasi, hambatan-hambatan, dan upaya-upaya dalam mengatasi ham­batan penerap­an ISO 9001: 2000 pada pembelajaran produktif. Penelitian ini diran­cang dengan menggunakan rancangan studi multisitus. Teknik pengum­pulan data meliputi wawan­cara, observasi partisipan, dan studi dokumentasi. Temuan penelitian adalah: (1 Penerapan ISO 9001: 2000 pada pem­belajaran pro­duktif teknik bangunan mengacu pada konsep P-D-C-A ke dalam sistem manajemen mutu ISO; (2 hambatan implementasi ISO 9001: 2000 pada pem­bel­ajaran produktif meliputi tingkat kesadaran rendah, inkonsistensi, dan ketidak­taatasasan; dan (3 upaya mengatasi hambatan dalam implementasi ISO 9001: 2000 pada pembelajar­an produk­tif meliputi membangun komitmen bersama, sosialisasi dalam rangka me­num­buhkan kesadaran bersama

  12. Radiological visualization of prosthetic heart valves in situ

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Pirschel, J.

    1986-01-01

    To determine the radiographic appearance of prosthetic heart valves 15 different models were investigated in situ. Fluoroscopy with detail radiographs and standard chest-radiographs were used for identification of the specific type of the prosthesis, for determination of details of the valve apparatus and for evaluation of the motion of the valve disc/ball. - Fluoroscopy and routine radiographs provided sufficient information to identify all prosthetic heart valves with exception of the Xenomedica bioprosthesis. If radiopaque material was used for the valve disc/ball, fluoroscopic assessment of the function of the valve was possible. Thus, in most types of disc or ball valves the opening/closing of the valve can be visualized, whereas in bioprosthesis a radiological determination of the mechanical function is not possible. (orig.) [de

  13. Non intrusive check valve diagnostics at Bruce A

    International Nuclear Information System (INIS)

    Marsch, S.P.

    1997-01-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  14. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  15. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...

  16. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    OpenAIRE

    Darwazah Ahmad K

    2012-01-01

    Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replace...

  17. Risk Factors for Late Aortic Valve Dysfunction After the David V Valve-Sparing Root Replacement.

    Science.gov (United States)

    Esaki, Jiro; Leshnower, Bradley G; Binongo, Jose N; Lasanajak, Yi; McPherson, LaRonica; Guyton, Robert A; Chen, Edward P

    2017-11-01

    Valve-sparing root replacement (VSRR) is an established therapy for aortic root pathology. However, late aortic valve dysfunction requiring reoperation remains a primary concern of this procedure. This study examines risk factors for late aortic insufficiency (AI) and aortic stenosis (AS) after David V VSRR. A retrospective review from 2005 to 2015 at a US academic center identified 282 patients who underwent VSRR. Cox proportional hazards regression analysis was used to identify risk factors for late AI and AS after VSRR. The mean age was 46.4 years. Sixty-four patients (22.7%) had bicuspid valves, and 41 patients (14.5%) had Marfan syndrome. The incidence of reoperations was 27 (9.6%), and 42 cases (14.9%) presented with acute type A dissection. Operative mortality was 8 (2.8%). Seven-year survival was 90.9%. Seven-year cumulative incidence of reoperation, greater than 2+ AI and greater than moderate AS were 3.1%, 2.2%, and 0.8%, respectively. Multivariable analysis showed aortic root size 55 mm or larger (hazard ratio 3.44, 95% confidence interval: 1.27 to 9.29, p = 0.01) to be a risk factor for late AI whereas bicuspid valve (hazard ratio 16.07, 95% confidence interval: 3.12 to 82.68, p = 0.001) and cusp repair were found to be risk factors (hazard ratio 5.91, 95% confidence interval: 1.17 to 29.86, p = 0.03) for late AS. Valve-sparing root replacement can be performed with low operative risk and good overall long-term survival even in complex clinical settings. Durable valve function can be expected; however, aortic root size 55 cm or more, bicuspid valve anatomy, and cusp repair represent independent risk factors for late aortic valve dysfunction after these procedures. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. ISO 26000 – An Integrative Approach of Corporate Social Responsibility

    Directory of Open Access Journals (Sweden)

    Herciu Mihaela

    2016-04-01

    Full Text Available ISO 26000 represents a guidance on corporate social responsibility and it is, at the present time, one of the most important document on CSR in the world. Without being mandatory or regulated, ISO 26000 is focus on seven core subjects that have to be approached synergistic – governance, human right, labor, environment, business practices, consumer, and community – in order to achieve its goal. The present paper intends to present and analyze the seven core subjects of ISO 26000 from tow perspectives: by emphasizing the benefits of implementing the standard into the business strategy and by revealing the correlation between corporate social responsibility and sustainable development.

  19. Safety valve including a hydraulic brake and hydraulic brake that could be fitted into a valve

    International Nuclear Information System (INIS)

    Chabat-Courrede, Jean.

    1981-01-01

    Making of a safety valve that can be fitted to a containment vessel filled with a non compressible fluid, such as the water system of a nuclear power station. It includes a hydraulic brake located between the valve and the elastic means, close to the valve which completely suppresses the high frequency oscillations of the equipment [fr

  20. 49 CFR 229.109 - Safety valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety valves. 229.109 Section 229.109..., DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Safety Requirements Steam Generators § 229.109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a...

  1. Automatic fire hydrant valve development

    International Nuclear Information System (INIS)

    Drumheller, K.

    1976-01-01

    The development of a remotely-controlled valve to operate a fire hydrant is described. Assembled from off-the-shelf components, the prototype illustrates that a valve light enough to be handled by one man is possible. However, it does not have the ruggedness or reliability needed for actual fire-fighting operations. Preliminary testing by City of Tacoma fire department personnel indicates that the valve may indeed contribute significantly to fire-fighting efficiency

  2. Valve and dash-pot assembly

    Science.gov (United States)

    Chang, Shih-Chih

    1986-01-01

    A dash-pot valve comprising a cylinder submerged in the fluid of a housing and having a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with tangentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  3. Operating experience and design criteria of sodium valves

    International Nuclear Information System (INIS)

    Markford, D.

    1974-01-01

    The information presented refers to sodium valve development for KNK and SNR-300 as well as for sodium test facilities on the INTERATOM site at Bensberg. Well in advance of KNK-I a number of sodium test facilities have been operated containing small and medium size valves of different design and manufacturer. The more stringent requirements for long range safe and reliable operation in KNK-I put forth a development program for the main primary and secondary circuit sodium valves. Operational experience gave rise to modification of the stem seal arrangement mainly, so KNK-II (which is the fast core for KNK reactor) will be run with modified sodium valves. Main pipe diameters in SNR-300 are in the range of 600 mm. Valve designs with rising shafts would require excessive space in the primary circuit cavities, therefore efforts have been directed towards introduction of different type valves. Due to the requirements of after-heat-removal a valve type with control capability had to be chosen. A special design of butterfly valves was selected for the primary and secondary circuits of SNR-300. The development and tests performed with this type of valve are described. In the field of small sodium valves, tests with a 50 mm diameter freeze-seal valve are reported, and the current status of bellows-seal-valves to be inserted into SNR-300 is discussed. (U.S.)

  4. Acoustic valve leak detection in nuclear plants

    International Nuclear Information System (INIS)

    Dimmick, J.G.; Dickey, J.W.

    1983-01-01

    Internal valve leakage is a hidden energy loss and can cause or prolong a forced outage. Recent advances in acoustic detection of internal valve leakage have reduced piping system maintenance costs, unnecessary downtime, and energy waste. Extremely short payback periods have been reported by plants applying this technology to preventive maintenance, troubleshooting, energy conservation and outage planning. Sensors temporarily attached to the outside of valves and connected to the instruments detect ultrasonic acoustic emissions which are characteristic of internal valve leakage. Since the sensors are attached to the outside of the valves, the time and expense of dismantling the valves or removing them from the systems are eliminated. This paper describes the instrumentation and specific applications to nuclear plant valves, including independent verification of initial findings. Guidelines for potential users, including instrumentation selection, training requirements, application planning, and the choice of in-house versus contract services are discussed

  5. Valve selection handbook engineering fundamentals for selecting the right valve design for every industrial flow application

    CERN Document Server

    Smith, Peter

    2004-01-01

    Valves are the components in a fluid flow or pressure system that regulate either the flow or the pressure of the fluid. They are used extensively in the process industries, especially petrochemical. Though there are only four basic types of valves, there is an enormous number of different kinds of valves within each category, each one used for a specific purpose. No other book on the market analyzes the use, construction, and selection of valves in such a comprehensive manner.-Covers new environmentally-conscious equipment and practices, the most important hot-button issue in the p

  6. Experience with control valve cavitation problems and their solutions

    International Nuclear Information System (INIS)

    Ozol, J.

    1988-01-01

    Pressure reduction in control valves can induce cavitation, which has three effects on the control valve. Firstly, it modifies or changes the hydraulic performance of the control valve. Since control valves are designed for noncavitating conditions, the result is usually reduced stability of the control valve or, in extreme cavitating conditions known as supercavitation, the valve may limit the flow rate and thus be undersized. Secondly, cavitation can cause material damage to valve parts, trim, or valve body, or erodes downstream piping; consequently, the valve or piping leaks. Thirdly, cavitation causes noise and vibration, which may cause major damage or destruction to equipment such as valve positioners, actuators, pipe supports and sometimes to other downstream valves. The purpose of this paper is twofold: (1) It describes the I.S.A. valve sizing equations and how they relate to cavitation. (2) It describes experiences with these three problems, and discusses corrective actions and practical approaches to their solution. This paper discusses thirteen cavitation experiences

  7. Control valve friction operational experience at Darlington NGD

    International Nuclear Information System (INIS)

    Speer, B.

    1995-01-01

    Proper installation of valve packing is an important part of ensuring that control valves operate as intended. Darlington NGD has developed a Valve Packing Program. This program combined with valve diagnostics has enabled the station to ensure that the operability of control valves is maintained after repacking. This paper outlines the process that is used for this. (author)

  8. Age, colors and ISO standards

    NARCIS (Netherlands)

    Nes, van F.L.; Eschbach, R; Marcu, G.G.; Tominaga, S.; Rizzi, A.

    2010-01-01

    Age influences all bodily functions, also vision. Therefore, the effects of age on vision should be mirrored in ergonomic requirements laid down in display standards such as ISO 9241-300/307, 'Electronic visual display requirements'. However, this is only true to a limited extent - just as is the

  9. ISO 14001: time for improvements?

    DEFF Research Database (Denmark)

    Jørgensen, Tine Herreborg

    2007-01-01

    The aim of this paper is to discuss a number of issues related to ISO 14001:2004, the international standard for Environmental Management Systems (EMS) with the purpose of improving the next edition in order to recognise and reflect new recognitions in approaches to pollution prevention. A case...

  10. An application of the valve-leak monitoring system to the valves for the improved Korean standard nuclear power plant (KSNP+)

    International Nuclear Information System (INIS)

    Byeong-yeol AHN; Dae-sik CHOI; Sang-kook CHUNG

    2006-01-01

    The loss of steam due to valve leakage leads to the inefficiency of power generation at the nuclear power plants. Under the normal conditions of plant operation, it is difficult to detect valve leaks early enough to prevent consequential damages and losses. The capability of timely detection allows the plant adequate time to prepare repair plans, which would ultimately result in efficient power production. Therefore, timing of detection is one of the most important factors in dealing with valve leakage problems. The VLMS has been developed to meet such an industrial demand. It provides early detection of valve leakage by real-time monitoring through the acoustic sensors installed on the inlet and the outlet of the valve. The KSNP+ utilizes the VLMS to enhance the performance and maintenance of major valves at plants. The VLMS will enable the plant to detect the leakage of valve at an early stage. It can reduce the steam losses and save related valve maintenance cost by performing fast diagnosis of valve leakage. (authors)

  11. Fetal MRI correlates with postnatal CT angiogram assessment of pulmonary anatomy in tetralogy of Fallot with absent pulmonary valve.

    Science.gov (United States)

    Sun, Heather Y; Boe, Justin; Rubesova, Erika; Barth, Richard A; Tacy, Theresa A

    2014-01-01

    In tetralogy of Fallot with absent pulmonary valve, pulmonary stenosis and regurgitation results in significant pulmonary artery dilatation. Branch pulmonary artery dilatation often compresses the tracheobronchial tree, causing fluid trapping in fetal life and air trapping and/or atelectasis after birth. Prenatal diagnosis predicts poor prognosis, which depends on the degree of respiratory insufficiency from airway compromise and lung parenchymal disease after birth. Fetal magnetic resonance imaging (MRI) has been useful in evaluating the effects of congenital lung lesions on lung development and indicating severity of pulmonary hypoplasia. This report is the first demonstrating the utility of fetal MRI in tetralogy of Fallot/absent pulmonary valve patients, which predicted postnatal pulmonary artery size and visualized airway compression and lung parenchymal lesions. The distribution of lobar fluid trapping on fetal MRI correlated with air trapping on postnatal computed tomography angiogram. © 2013 Wiley Periodicals, Inc.

  12. Specification of Energy Assessment Methodologies to Satisfy ISO 50001 Energy Management Standard

    Science.gov (United States)

    Kanneganti, Harish

    Energy management has become more crucial for industrial sector as a way to lower their cost of production and in reducing their carbon footprint. Environmental regulations also force the industrial sector to increase the efficiency of their energy usage. Hence industrial sector started relying on energy management consultancies for improvements in energy efficiency. With the development of ISO 50001 standard, the entire energy management took a new dimension involving top level management and getting their commitment on energy efficiency. One of the key requirements of ISO 50001 is to demonstrate continual improvement in their (industry) energy efficiency. The major aim of this work is to develop an energy assessment methodology and reporting format to tailor the needs of ISO 50001. The developed methodology integrates the energy reduction aspect of an energy assessment with the requirements of sections 4.4.3 (Energy Review) to 4.4.6 (Objectives, Targets and Action Plans) in ISO 50001 and thus helping the facilities in easy implementation of ISO 50001.

  13. Implementation of ISO 10110 optics drawing standards for the National Ignition Facility

    International Nuclear Information System (INIS)

    Aikens, D. M.; English, R. E.; Wang, D. Y.

    1999-01-01

    The National Ignition Facility (NIF) project elected to implement ISO 10110 standard for the specifications of NIF optics drawings in 1996. More than 7,000 NIF large optics and 20,000 NIF small optics will be manufactured based on ISO 10110 indications. ISO 10110 standard meets many of the needs of the NIF optics specifications. It allows the optical engineer to quantify and clearly communicate the desired optical specifications. While no single drawing standard specifies all the requirements of high energy laser system, a combination of ISO 10110 standard with detailed notes make it possible to apply international drawing standards to the NIF laser system. This paper will briefly describe LLNL's interpretation and implementation of the ISO 10110 drawing standard, present some examples of NIF optics drawings, and discuss pros and cons of the indications from the perspective of this application. Emphasis will be given to the surface imperfection specifications, known as 5/, for the NIF optics

  14. Implementation of ISO 10110 optics drawing standards for the National Ignition Facility

    Science.gov (United States)

    Wang, David Y.; English, R. Edward, Jr.; Aikens, David M.

    1999-11-01

    The National Ignition Facility (NIF) project elected to implement ISO 10110 standard for the specifications of NIF optics drawings in 1996. More than 7,000 NIF large optics and 20,000 NIF small optics will be manufactured based on ISO 10110 indications. ISO 10110 standard meets many of the needs of the NIF optics specifications. It allows the optical engineer to quantify and clearly communicate the desired optical specifications. While no single drawing standard specifies all the requirements of high energy laser system, a combination of ISO 10110 standard with detailed notes make it possible to apply international drawing standards to the NIF laser system. This paper will briefly describe LLNL's interpretation and implementation of the ISO 10110 drawing standard, present some examples of NIF optics drawings, and discuss pros and cons of the indications from the perspective of this application. Emphasis will be given to the surface imperfection specifications, known as 5/, for the NIF optics.

  15. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  16. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  17. Plasma 8-iso-Prostaglandin F2α, a possible prognostic marker in aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Pan, De-Sheng; Yan, Min; Hassan, Muhammad; Fang, Ze-Bin; Chen, Man-Tao

    2017-06-01

    8-iso-Prostaglandin F2α (8-iso-PGF2α) is a potential biomarker of oxidative stress. This study clarified whether plasma 8-iso-PGF2α concentrations were affected and its underlying relevance to prognosis in aneurysmal subarachnoid hemorrhage (aSAH). In this prospective, observational study, a total of 170 controls and 170 aSAH patients were enrolled. Plasma 8-iso-PGF2α concentrations were detected using an ELISA. Severity was assessed by World Federation of Neurological Surgeons (WFNS) scale and modified Fisher grading scale. Clinical outcomes included 6-month mortality and poor outcome referred to as Glasgow outcome scale score of 1-3. As compared to controls, admission plasma 8-iso-PGF2α concentrations were significantly enhanced. Increased concentrations of plasma 8-iso-PGF2α correlated with WFNS scores and modified Fisher scores. 8-iso-PGF2α in plasma was an independent predictor for clinical outcomes. Under ROC curve, the predictive values of 8-iso-PGF2α concentrations resembled those of WFNS scores and modified Fisher scores for clinical outcomes. An elevation in plasma 8-iso-PGF2α concentrations is associated with the severity and poor outcome after aSAH, substantializing 8-iso-PGF2α as a potential prognostic biomarker of aSAH. Copyright © 2017. Published by Elsevier B.V.

  18. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  19. Bentall Operation with Valved Homograft Conduit

    Science.gov (United States)

    Choudhary, Shiv K.; Talwar, Sachin; Kumar, A. Sampath

    2000-01-01

    Lesions of the ascending aorta associated with aortic valve disease are usually treated by implanting a prosthetic valved conduit (Bentall procedure). In this report, we present our experience in which a valved homograft conduit was used for the procedure. Six patients underwent a Bentall procedure with the use of a cryopreserved valved homograft conduit. Two of the patients had annuloaortic ectasia, 2 had Marfan syndrome, and 1 had an atherosclerotic aneurysm of the aorta. One patient had severe aortic stenosis due to a bicuspid aortic valve, along with an aneurysm and localized dissection of the ascending aorta. In all of the patients, the aortic annulus was substantially dilated, with accompanying moderate-to-severe aortic regurgitation. A standard procedure was performed with moderate hypothermia, cardiopulmonary bypass, and aortic and bicaval cannulation. The ascending aorta and the aortic valve were replaced with a cryopreserved valved homograft conduit (aortic in 5 patients and pulmonary in 1). The native coronary ostia were anastomosed directly to the homograft. Echocardiography, which was performed intraoperatively, before discharge from the hospital, and at follow-up visits (1 to 36 months), revealed good valve function without dilatation of the homograft conduits. There was 1 late death due to Aspergillus fumigatus endocarditis, 6 months postoperatively. In 1 patient, magnetic resonance imaging performed at 24 months revealed normal caliber of the homograft conduit. We conclude that the Bentall procedure can be performed, safely and with excellent results, using cryopreserved homograft conduits. PMID:11198310

  20. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...... (NOAF) is 31%-64% and 4%-32%, respectively. NOAF is independently associated with adverse events such as stroke, death, and increased length of hospital stay. Increasing the knowledge of predisposing factors, optimal postprocedural monitoring, and prophylactic antiarrhythmic and antithrombotic therapy...

  1. New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...... (NOAF) is 31%-64% and 4%-32%, respectively. NOAF is independently associated with adverse events such as stroke, death, and increased length of hospital stay. Increasing the knowledge of predisposing factors, optimal postprocedural monitoring, and prophylactic antiarrhythmic and antithrombotic therapy...

  2. The use of valves in the SAGD process

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Michael A. [Global Marketing, Oil and Gas, Tyco Valves and Controls (United States)

    2011-07-01

    Steam-assisted gravity drainage (SAGD) is a developing technology, the aim of which is to increase production of bitumen while minimizing its environmental footprint. Valves must meet the process conditions of the operations, which depend on weel depth: deeper reservoirs of bitumen require higher steam injection pressure. A wide range of valves is used throughout the SAGD process. In the water softening plant, butterfly and process lined valves are used. HP gate valves are used for isolation, globe valves for vents/drains/bypasses, along with ARC valves for steam and booster pump projection with steam traps on injection lines in steam injection. Isolation valves are used throughout the low pressure process including ball, gate and triple-offset valves. Pressure management is carried out on all pressure vessels and lines. Control and choke valves are installed on well pads and production. Instrumentation, actuation and controls are installed throughout. In the ideal situation, suppliers and process engineers would work together in the early stages of a project.

  3. 75 FR 5779 - Notice Providing Agenda for Technical Conference on RTO/ISO Responsiveness

    Science.gov (United States)

    2010-02-04

    ... Conference on RTO/ISO Responsiveness January 27, 2010. California Independent System Operator Docket No. ER09.... Southwest Power Pool, Inc Docket Nos. ER09-1050-000, ER09- 1192-000. ISO New England, Inc. and New England.... Agenda--Technical Conference on RTO/ISO Responsiveness February 4, 2010 12:30 Panel 1--Stakeholder...

  4. [Right branch pulmonary artery stenosis with supravalvar aortic stenosis as a complication of Lecompte maneuver for tetralogy of Fallot associated with absent pulmonary valve].

    Science.gov (United States)

    Honda, Yoshihiro; Suzuki, Shoji; Kaga, Shigeaki; Yoshida, Yukiyo; Kimura, Mitsuhiro; Kamiya, Kentaro; Sakakibara, Kenji; Katsu, Masatake

    2015-05-01

    The patient was diagnosed with tetralogy of Fallot associated with absent pulmonary valve syndrome and a low birth weight of 1,912 g. He suffered from respiratory distress on day 14 and received non-invasive positive pressure ventilation. At 5 months of age and 4.1 kg, he underwent intracardiac repair including right ventricular outflow repair with a monocusp patch, patch closure of the ventricular septum defect and right pulmonary transposition to the anterior of the ascending aorta following the Lecompte maneuver for airway decompression. He was subsequently discharged to home and exhibited an uneventful clinical course with non-invasive positive pressure ventilation for 5 months postoperatively. However, right pulmonary artery and supra-aortic stenosis was noted 2 years after the operation. Computed tomography (CT) and angiography showed ascending aorta strangulation by the right pulmonary artery with right ventricular outflow regurgitation. Right pulmonary artery reconstruction using polytetrafluoroethylene graft interposition and repeat right ventricular outflow repair with bicuspid hand-sewn valves was therefore performed;the postoperative course was uneventful. Pre- and post-operative management using non-invasive positive pressure ventilation and airway decompression with pulmonary artery translocation is a useful strategy in patients exhibiting symptomatic tetralogy of Fallot associated with absent pulmonary valve syndrome in the neonatal period.

  5. ISO 9000 Series Certification Over Time: what have we learnt?

    NARCIS (Netherlands)

    A. van der Wiele (Ton); A.M. Brown (Alan)

    2002-01-01

    textabstractThe ISO 9000 experiences of the same sample of organisations over a five year time period is examined in this paper. The responses to a questionnaire sent out at the end of 1999 to companies which had a reasonably long term experience with the ISO 9000 series quality system are analysed.

  6. Quality standards: Comparison between IAEA 50-C/SG-Q and ISO 9001:2000

    International Nuclear Information System (INIS)

    2002-01-01

    The International Atomic Energy Agency (IAEA) has the statutory mandate to seek to accelerate and enlarge the contribution of atomic energy to peace, health and prosperity throughout the world. As part of the activities to achieve its objectives, the IAEA is authorized to establish standards of safety for the protection of health and the minimization of danger to life and property. The standards of safety developed by the IAEA are recommendations for use by its Member States in the framework of national regulations for the safe utilization of nuclear energy. Such standards should be considered as nuclear safety regulatory documents. The standards developed by the International Organization for Standardization (ISO) are complementary technical documents emphasizing industrial application and contractual aspects. Regarding the quality assurance topic, the IAEA developed the publication Safety Series No. 50-C/SG-Q, Quality Assurance for Safety in Nuclear Power Plants and other Nuclear Installations, which is mostly used directly or indirectly to establish the nuclear safety requirements at the nuclear utility-regulator interface. The ISO 9001:2000 standard, Quality Management Systems Requirements, is often used to define the quality management system requirements at the utility-supplier interface. The relationship between the IAEA and ISO quality standards is growing in significance owing to their increasing impact upon utilities (owners/operators of nuclear facilities) and their contractors/suppliers. The relationship between the IAEA and ISO standards is considered critical in particular with respect to contractors/suppliers with a small range of nuclear supplies. These contractors-suppliers are not always willing to prepare special quality assurance programmes based on nuclear safety standards. On the other hand, these contractors/suppliers may be qualified on the basis of the ISO quality standard. In any case, for delivering nuclear items and services the

  7. Fate of remnant sinuses of Valsalva in patients with bicuspid and trileaflet valves undergoing aortic valve, ascending aorta, and aortic arch replacement.

    Science.gov (United States)

    Milewski, Rita Karianna; Habertheuer, Andreas; Bavaria, Joseph E; Siki, Mary; Szeto, Wilson Y; Krause, Eric; Korutla, Varun; Desai, Nimesh D; Vallabhajosyula, Prashanth

    2017-08-01

    In patients presenting with aortic valvulopathy with concomitant ascending aortic aneurysm, surgical management of the sinus of Valsalva segment remains undefined, especially for moderately dilated aortic roots. In patients with this pathology undergoing aortic valve replacement with supracoronary ascending aorta replacement, we assessed the fate of the remnant preserved sinus of Valsalva segment stratified by aortic valve morphology and pathology. From 2002 to 2015, 428 patients underwent elective aortic valve replacement with supracoronary ascending aorta replacement. Patients were stratified on the basis of valvular morphology (bicuspid aortic valve [n = 254] and tricuspid aortic valve [n = 174]), valvular pathology (bicuspid aortic valve with aortic stenosis [n = 178], bicuspid aortic valve with aortic insufficiency [n = 76], tricuspid aortic valve with aortic stenosis [n = 61], tricuspid aortic valve with aortic insufficiency [n = 113]), and preoperative sinus of Valsalva dimensions (45 mm). Kaplan-Meier analysis revealed no significant difference in freedom from reoperation in tricuspid aortic valve versus bicuspid aortic valve (P = .576). Multivariable Cox regression model performed with sinus of Valsalva dimensions at baseline and follow-up as time-varying covariates did not adversely affect survival. A repeated-measure, mixed-effects model constructed to assess longitudinal sinus of Valsalva trends revealed that the retained sinus of Valsalva dimensions remain stable over long-term follow-up (discharge to ≥10 years), irrespective of valvular morphology/pathology (bicuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic stenosis) and preoperative sinus of Valsalva groups (45 mm). In patients with nonaneurysmal sinuses of Valsalva undergoing aortic valve replacement with supracoronary ascending aorta replacement, the sinus segment can be preserved irrespective of

  8. Additively Manufactured Main Fuel Valve Housing

    Science.gov (United States)

    Eddleman, David; Richard, Jim

    2015-01-01

    Selective Laser Melting (SLM) was utilized to fabricate a liquid hydrogen valve housing typical of those found in rocket engines and main propulsion systems. The SLM process allowed for a valve geometry that would be difficult, if not impossible to fabricate by traditional means. Several valve bodies were built by different SLM suppliers and assembled with valve internals. The assemblies were then tested with liquid nitrogen and operated as desired. One unit was also burst tested and sectioned for materials analysis. The design, test results, and planned testing are presented herein.

  9. Branches of the Facial Artery.

    Science.gov (United States)

    Hwang, Kun; Lee, Geun In; Park, Hye Jin

    2015-06-01

    The aim of this study is to review the name of the branches, to review the classification of the branching pattern, and to clarify a presence percentage of each branch of the facial artery, systematically. In a PubMed search, the search terms "facial," AND "artery," AND "classification OR variant OR pattern" were used. The IBM SPSS Statistics 20 system was used for statistical analysis. Among the 500 titles, 18 articles were selected and reviewed systematically. Most of the articles focused on "classification" according to the "terminal branch." Several authors classified the facial artery according to their terminal branches. Most of them, however, did not describe the definition of "terminal branch." There were confusions within the classifications. When the inferior labial artery was absent, 3 different types were used. The "alar branch" or "nasal branch" was used instead of the "lateral nasal branch." The angular branch was used to refer to several different branches. The presence as a percentage of each branch according to the branches in Gray's Anatomy (premasseteric, inferior labial, superior labial, lateral nasal, and angular) varied. No branch was used with 100% consistency. The superior labial branch was most frequently cited (95.7%, 382 arteries in 399 hemifaces). The angular branch (53.9%, 219 arteries in 406 hemifaces) and the premasseteric branch were least frequently cited (53.8%, 43 arteries in 80 hemifaces). There were significant differences among each of the 5 branches (P < 0.05) except between the angular branch and the premasseteric branch and between the superior labial branch and the inferior labial branch. The authors believe identifying the presence percentage of each branch will be helpful for surgical procedures.

  10. Anatomic characteristics of bileaflet mitral valve prolapse--Barlow disease--in patients undergoing mitral valve repair.

    Science.gov (United States)

    Rostagno, Carlo; Droandi, Ginevra; Rossi, Alessandra; Bevilacqua, Sergio; Romagnoli, Stefano; Montesi, Gian Franco; Stefàno, Pier Luigi

    2014-01-01

    Barlow disease is a still challenging pathology for the surgeon. Aim of the present study is to report anatomic abnormalities of mitral valve in patients undergoing mitral valve repair. Between January 1st, 2007, and December 31st, 2010, 85 consecutive patients (54 men and 31 women, mean age 59 +/- 14 years--range: 28-85 years) with the features of a Barlow mitral valve disease underwent mitral repair Forty seven percent of patients were in New York Heart Association functional class III or IV. Preoperative transesophageal echocardiography was compared with anatomical findings at the moment of surgery. Transthoracic echocardiography diagnosis of Barlow disease according to the criteria described by Carpentier was confirmed at anatomical inspection. Annular calcifications were found in 28 patients while 7 patients presented single or multiple clefts. A flail posterior mitral leaflet was detected in 32 subjects, while a flail anterior leaflet in 8. Elongation of chordae tendineae was demonstrated in 45 patients and chordal rupture in 31. All patients showed at trans esophageal echocardiography the typical features of Barlow disease. Seventy-seven (90.6%) patients had severe mitral valve regurgitation, in the remaining 9.4% it was moderate to severe. Transesophageal echocardiography failed to identify clefts in 2/7 and chordal rupture in 4/31. bileaflet prolapse > 2 mm, billowing valve with excess tissue and thickened leaflets > or = 3 mm, and severe annular dilatation, are characteristics of Barlow disease, however the identification of the associated and complex abnormalities of mitral valve is necessary to obtain optimal valve repair.

  11. ISO 14001: implementar ou não? Uma proposta para a tomada de decisão ISO 14001: adopt it or not? A proposal for the decision making process

    Directory of Open Access Journals (Sweden)

    Giuliano Nacarato Moretti

    2008-12-01

    Full Text Available Entre as vantagens e desvantagens oferecidas pela implementação da norma ISO 14001, o empresário, muitas vezes, não encontra subsídios suficientes para a tomada de decisão pela adoção ou não da referida norma. Este trabalho apresenta uma ferramenta de auxílio à tomada de decisão empresarial, promovendo um estudo sobre a real necessidade e viabilidade da implementação da norma ISO 14001 e a respectiva certificação. Trata-se de uma análise multicriterial, em que se verifica a compatibilidade entre o perfil organizacional e a norma ISO 14001. Busca-se facilitar a decisão das organizações em adotar ou não a ISO 14001, por meio de uma recomendação que aumente sua probabilidade de atingir os objetivos almejados. A ferramenta demonstrou sua forte aplicabilidade quando implementada em duas empresas.One of the difficulties of the decision making process, is that many entrepreneurs may find themselves incapable of finding enough subsidies for the decision of adopting or not the ISO 14001 standard. This work presents a tool that facilitates corporate decision making, providing a thorough analysis of the real necessity and feasibility of the implementation of the ISO 14001 standard and its certification. This tool consists of a multicriterial analysis, in which is possible to verify the compatibility between the organizational profile and the ISO 14001 standard. This recommendation of adopting or not the ISO 14001 standard seeks to facilitate the organization decision making; and, as a result, it also enhances the probability of the organization attaining its objectives. This tool presented a strong applicability when implemented in two companies.

  12. PERBANDINGAN IMPLEMENTASI ISO DAN PELUNCURAN ENTERPRISE RESOURCES PLANNING TERHADAP INDEKS KINERJA KEUANGAN

    Directory of Open Access Journals (Sweden)

    Sautma Ronni Basana

    2017-03-01

    Full Text Available Recently, companies implemented projects which applied on companies’ overall system. These recent bestpractices of pursuing companies’ effectiveness and efficiency would be implementation of ISO 9000 and ERP.Previous research showed that these two projects could bring benefits for these companies which implementedit. However, it had not been compared which project would bring more benefits to these companies. Thisresearch observed 35 companies which consisted of 15 companies in food and beverages industry, 9 companiesin pharmaceutical industry, 4 companies in cigarettes industry, 4 companies in cosmetics industry, and 3companies in household appliances industry. The data were taken by observing and recording the valueswhich related to COGS (cost of goods sold, total inventory, net income, gross income, operating income, pretaxincome, cash flow operation, total liabilities, and total asset after ISO and ERP implementation. The resultsshowed that there was no significant difference of the ISO and ERP implementation on the factors of inventoryturnover, and weeks of supply. While the other factors showed significant differences between the implementationof ERP and ISO. Net profit margin, gross profit margin, and operating profit margin showed better resulton ERP launching. On the other hand, pretax margin showed better than ISO 9000 implementation. Overall,ERP implementation showed better results compared with ISO 9000.

  13. Iso-vector form factors of the delta and nucleon in QCD sum rules

    International Nuclear Information System (INIS)

    Ozpineci, A.

    2012-01-01

    Form factors are important non-perturbative properties of hadrons. They give information about the internal structure of the hadrons. In this work, iso-vector axial-vector and iso-vector tensor form factors of the nucleon and the iso-vector axial-vector Δ→N transition form factor calculations in QCD Sum Rules are presented.

  14. Cavitation noise from butterfly valves

    International Nuclear Information System (INIS)

    Rahmeyer, W.J.

    1982-01-01

    Cavitation in valves can produce levels of intense noise. It is possible to mathematically express a limit for a design level of cavitation noise in terms of the cavitation parameter sigma. Using the cavitation parameter or limit, it is then possible to calculate the flow conditions at which a design level of cavitation noise will occur. However, the intensity of cavitation increases with the upstream pressure and valve size at a constant sigma. Therefore, it is necessary to derive equations to correct or scale the cavitation limit for the effects of different upstream pressures and valve sizes. The following paper discusses and presents experimental data for the caviation noise limit as well as the cavitation limits of incipient, critical, incipient damage, and choking cavitation for butterfly valves. The main emphasis is on the design limit of caviation noise, and a noise level of 85 decibels was selected as the noise limit. Tables of data and scaling exponents are included for applying the design limits for the effects of upstream pressure and valve size. (orig.)

  15. Plunger with simple retention valve

    International Nuclear Information System (INIS)

    Fekete, A.V.

    1987-01-01

    This patent describes a positive displacement retention valve apparatus in which the actual flow equals the theoretical maximum flow through the retention valve. The apparatus includes, in combination, a confined fluid flow conduit, a piston adapted for reciprocal movement within the fluid flow conduit between upstream and downstream limit positions, piston reciprocating means, and pressure responsive check valve means located upstream with respect to the piston in the fluid flow conduit. The pressure responsive check valve means operable to permit fluid flow therethrough in a downstream direction toward the piston, and to preclude fluid flow therethrough in an opposite direction. The piston is composed of parts which are relatively movable with respect to one another. The piston includes a simple retention valve consisting of a plug means, a cylinder having a minimum and a maximum internal cross section flow area therein and being reciprocal within the confined fluid flow conduit, and a seat on the cylinder for the plug means. The piston reciprocating means are operatively connected to the plug means

  16. Is valve choice a significant determinant of paravalular leak post-transcatheter aortic valve implantation? A systematic review and meta-analysis.

    Science.gov (United States)

    O'Sullivan, Katie E; Gough, Aideen; Segurado, Ricardo; Barry, Mitchel; Sugrue, Declan; Hurley, John

    2014-05-01

    Paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) is associated with poor survival. The two main valve delivery systems used to date differ significantly in both structure and deployment technique. The primary objective of this study was to perform a systematic review and meta-analysis of studies identifying PVR in patients post-TAVI using Medtronic CoreValve (MCV) and Edward Sapien (ES) valves in order to identify whether a significant difference exists between valve types. The secondary objective was to identify additional factors predisposing to PVR to provide an overview of the other associated considerations. A systematic review and meta-analysis of the current literature to identify PVR rate in patients with MCV and ES valves was performed. We also sought to examine other factors predisposing to PVR. A total of 5910 patients were identified from 9 studies. PVR rates for MCV and ES were analysed. MCV was associated with a higher PVR rate of 15.75% [95% confidence interval (CI) 12.48-19.32] compared with ES 3.93% [95% CI 1.05-8.38]. We separately reviewed predisposing factors associated with PVR. A formal comparison of the MCV and ES valve leakage rates by mixed-effects meta-regression with a fixed-effect moderator variable for valve type (MCV or ES) suggested a statistically significant difference in leakage rate between the two valve types (P = 0.0002). Unfavourable anatomical and pathological factors as well as valve choice have an impact on rates of PVR. Additionally, certain anatomical features dictate valve choice. A direct comparison of all the predisposing factors at this time is not possible and will require prospective multivariate analysis. There is, however, a significant difference in the PVR rates between valves based on the published observational data available to date. The ES valve associated with a lower incidence of PVR overall; therefore, we conclude that valve choice is indeed a significant

  17. David valve-sparing aortic root replacement: equivalent mid-term outcome for different valve types with or without connective tissue disorder.

    Science.gov (United States)

    Kvitting, John-Peder Escobar; Kari, Fabian A; Fischbein, Michael P; Liang, David H; Beraud, Anne-Sophie; Stephens, Elizabeth H; Mitchell, R Scott; Miller, D Craig

    2013-01-01

    Although implicitly accepted by many that the durability of valve-sparing aortic root replacement in patients with bicuspid aortic valve disease and connective tissue disorders will be inferior, this hypothesis has not been rigorously investigated. From 1993 to 2009, 233 patients (27% bicuspid aortic valve, 40% Marfan syndrome) underwent Tirone David valve-sparing aortic root replacement. Follow-up averaged 4.7 ± 3.3 years (1102 patient-years). Freedom from adverse outcomes was determined using log-rank calculations. Survival at 5 and 10 years was 98.7% ± 0.7% and 93.5% ± 5.1%, respectively. Freedom from reoperation (all causes) on the aortic root was 92.2% ± 3.6% at 10 years; 3 reoperations were aortic valve replacement owing to structural valve deterioration. Freedom from structural valve deterioration at 10 years was 96.1% ± 2.1%. No significant differences were found in survival (P = .805, P = .793, respectively), reoperation (P = .179, P = .973, respectively), structural valve deterioration (P = .639, P = .982, respectively), or any other functional or clinical endpoints when patients were stratified by valve type (tricuspid aortic valve vs bicuspid aortic valve) or associated connective tissue disorder. At the latest echocardiographic follow-up (95% complete), 202 patients (94.8%) had none or trace aortic regurgitation, 10 (4.7%) mild, 0 had moderate to severe, and 1 (0.5%) had severe aortic regurgitation. Freedom from greater than 2+ aortic regurgitation at 10 years was 95.3% ± 2.5%. Six patients sustained acute type B aortic dissection (freedom at 10 years, 90.4% ± 5.0%). Tirone David reimplantation valve-sparing aortic root replacement in carefully selected young patients was associated with excellent clinical and echocardiographic outcome in patients with either a tricuspid aortic valve or bicuspid aortic valve. No demonstrable adverse influence was found for Marfan syndrome or connective tissue disorder on durability, clinical outcome

  18. 49 CFR 195.260 - Valves: Location.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves: Location. 195.260 Section 195.260... PIPELINE Construction § 195.260 Valves: Location. A valve must be installed at each of the following locations: (a) On the suction end and the discharge end of a pump station in a manner that permits isolation...

  19. A search for PAHs in the ISO spectra of comet Hale-Bopp

    Science.gov (United States)

    Crovisier, J.; Bockelée-Morvan, D.

    2007-12-01

    From a new analysis of a spectrum of comet C/1995 O1 (Hale-Bopp) obtained with the Infrared Space Observatory (ISO), Lisse et al. (2007) claimed the identification of many new dust species. Among them are PAHs, which were not found in our first analysis of the ISO spectra. We present a re-examination of the ISO observations of comet Hale-Bopp, which does not confirm the conclusion of Lisse et al.

  20. U-value measurements on ISO round Robin window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1997-01-01

    9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust.......9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust....

  1. The new ISO 6579-1: A real horizontal standard for detection of Salmonella, at last!

    Science.gov (United States)

    Mooijman, Kirsten A

    2018-05-01

    Up to 2016, three international standard methods existed for the detection of Salmonella spp. in food, animal feed and samples from the primary production stage: ISO 6785:2001 for milk and milk products, ISO 6579:2002 for (other) food and animal feed and Annex D of ISO 6579:2007 for samples from the primary production stage. In 2009, an ISO/CEN working group started with the revision of ISO 6579:2002 with two main aims: combining the three aforementioned standards in one document and improving the information in ISO 6579:2002. Additionally it was decided to split ISO 6579 into three parts, where part 1 describes the detection, part 2 the enumeration by mini-MPN (published in 2012) and part 3 the serotyping of Salmonella (published in 2014). This paper describes the experiments and choices made for improving the part on detection of Salmonella (ISO 6579-1). The final voting stage on (draft) ISO 6579-1 was finished by the end of December 2016, with a positive outcome. Finally, a real horizontal standard became available for detection of Salmonella in food, animal feed, environmental samples in the area of food production and food handling and in samples from the primary production stage in 2017. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses.

    Science.gov (United States)

    Seiffert, Moritz; Conradi, Lenard; Baldus, Stephan; Knap, Malgorzata; Schirmer, Johannes; Franzen, Olaf; Koschyk, Dietmar; Meinertz, Thomas; Reichenspurner, Hermann; Treede, Hendrik

    2012-03-01

    Transcatheter valve-in-valve implantation is evolving as an alternative to reoperative valve replacement in high-risk patients with degenerated bioprostheses. Nevertheless, hemodynamic performance is limited by the previously implanted xenograft. We report our experience with patient-prosthesis mismatch (PPM) after valve-in-valve implantation in the aortic position. Eleven patients (aged 79.3 ± 6.1 years) received transapical implantation of a balloon-expandable pericardial heart valve into a degenerated bioprosthesis (size, 23.9 ± 1.6 mm; range, 21-27 mm) in the aortic position. All patients were considered high risk for surgical valve replacement (logistic European System for Cardiac Operative Risk Evaluation, 31.8% ± 24.1%). Severe PPM was defined as an indexed effective orifice area less than 0.65 cm(2)/m(2), determined by discharge echocardiography. Severe PPM was evident in 5 patients (group 1) and absent in 6 patients (group 2). Mean transvalvular gradients decreased from 29.2 ± 15.4 mm Hg before implantation to 21.2 ± 9.7 mm Hg at discharge (group 1) and from 28.2 ± 9.0 mm Hg before implantation to 15.2 ± 6.5 mm Hg at discharge (group 2). Indexed effective orifice area increased from 0.5 ± 0.1 cm(2)/m(2) to 0.6 ± 0.1 cm(2)/m(2) and from 0.6 ± 0.3 cm(2)/m(2) to 0.8 ± 0.3 cm(2)/m(2). Aortic regurgitation decreased from grade 2.0 ± 1.1 to 0.4 ± 0.5 overall. No differences in New York Heart Association class improvement or survival during follow-up were observed. One patient required reoperation for symptomatic PPM 426 days after implantation. Valve-in-valve implantation can be performed in high-risk surgical patients to avoid reoperation. However, PPM frequently occurs, making adequate patient selection crucial. Small bioprostheses (body surface area less than 1.8 m(2). Larger prostheses seem to carry a lower risk for PPM. Although no delay in clinical improvement was seen at short-term, 1 PPM-related surgical intervention raises concern regarding

  3. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair with the ...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  4. Preliminary assessment of valve IST effectiveness

    International Nuclear Information System (INIS)

    Grove, E.; DiBiasio, A.; Carbonaro, J.

    1994-01-01

    A preliminary review of inservice testing effectiveness for Code Class 1,2, and 3 valves at nuclear power plants was performed. These requirements are specified by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI, and the Operations and Maintenance Standard. The Institute of Nuclear Power Operations Nuclear Plant Reliability Data System (NPRDS) database was used to provide failure reports for these components for 1988 to 1992. This time period coincides with the issuance of Generic Letter 89-04, which resulted in a more consistent application of the requirements by the licensees. For this time period, 8,593 valve failures were identified. From the review of the NPRDS database, the primary failure causes and failure modes for motor-operated valves (MOV), air-operated valves (AOV), and check valves (CV) were identified. Solenoid-operated valves were not reviewed in this study. Plant testing programs were effective in identifying approximately 60% of the CV failures, 46% of the AOV failures, and 44% of the MOV failures

  5. α-Iso-cubebene exerts neuroprotective effects in amyloid beta stimulated microglia activation.

    Science.gov (United States)

    Park, Sun Young; Park, Se Jin; Park, Nan Jeong; Joo, Woo Hong; Lee, Sang-Joon; Choi, Young-Whan

    2013-10-25

    Schisandra chinensis is commonly used for food and as a traditional remedy for the treatment of neuronal disorders. However, it is unclear which component of S. chinensis is responsible for its neuropharmacological effects. To answer this question, we isolated α-iso-cubebene, a dibenzocyclooctadiene lignin, from S. chinensis and determined if it has any anti-neuroinflammatory and neuroprotective properties against amyloid β-induced neuroinflammation in microglia. Microglia that are stimulated by amyloid β increased their production of pro-inflammatory cytokines and chemokines, prostaglandin E2 (PGE2), nitric oxide (NO) and reactive oxygen species (ROS) and the enzymatic activity of matrix metalloproteinase 9 (MMP-9). We found this was all inhibited by α-iso-cubebene. Consistent with these results, α-iso-cubebene inhibited the expression of inducible nitric oxide synthase (iNOS), cyclooxygenase 2 (COX-2) and MMP-9 in amyloid β-stimulated microglia. Subsequent mechanistic studies revealed that α-iso-cubebene inhibited the phosphorylation and degradation of IκB-α, the phosphorylation and transactivity of NF-κB, and the phosphorylation of MAPK in amyloid β-stimulated microglia. These results suggest that α-iso-cubebene impairs the amyloid β-induced neuroinflammatory response of microglia by inhibiting the NF-κB and MAPK signaling pathways. Importantly, α-iso-cubebene can provide critical neuroprotection for primary cortical neurons against amyloid β-stimulated microglia-mediated neurotoxicity. To the best of our knowledge, this is the first report showing that α-iso-cubebene can provide neuroprotection against, and influence neuroinflammation triggered by, amyloid β activation of microglia. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. ISO sertifikaat aitab otsustada / Toomas Udu

    Index Scriptorium Estoniae

    Udu, Toomas

    2005-01-01

    Ilmunud ka: Delovõje Vedomosti : Transport i logistika 25. mai lk. 8. Teenuse kvaliteedi näitajad logistikafirmas ISO standardi alusel. Vt. samas: Eestis kasutatakse kolme kvaliteedistandardit; Kuidas mõjutada kvaliteeti läbi juhtimissüsteemi

  7. Gaining competitive advantage in personal dosimetry services through ISO 9001 certification

    International Nuclear Information System (INIS)

    Noriah, M.A.

    2005-01-01

    Full text: In Malaysia, the harmonization of dose monitoring for almost 12,000 radiation workers is assigned to the Secondary Standard Dosimetry Laboratory of Malaysian Institute for Nuclear Technology Research, SSDL-MINT. Established in 1980, SSDL-MINT is responsible for improving personal and workplace safety by providing high quality personal dosimetry services. It is important to demonstrate that the performance of personal dosimetry meets recognized standards, to ensure radiation doses to individual workers are within the safe limits and to verify compliance with dose limits. Concern on the quality of personal dosimetry service began to be expressed in 2000. The concern led to the ISO certification, which brought an unprecedented effort characterized by high degree coordination, proper documentation and well trained of personal dosimetry operators. These huge efforts resulted with certification ISO 9002:1994 by the SIRIM International QAS Sdn. Bhd. in January 2002. The adoption of these requirements for the ISO 9002 standard makes routine handling of the process easier, and increases the reliability and effectiveness of the services. This helps to increase the quality and uniformity of personal dosimetry. The revision of the ISO 9002:1994 to ISO 9001:2000 necessitated SSDL-MINT revising its quality management system. The work began in middle 2002, and by May 2003, SSDL-MINT has been upgraded to ISO 9001:2000. Certification to the ISO 9001:2000 demonstrates our ability to consistency provide service that meets the requirements of the customer and the regulatory authority. These includes: improved consistency of service / product performance and therefore higher customer satisfaction levels; uniformity in work processes across organizations; simplified and more uniform structure for quality documents; improved customer perception of the organizations image, culture and performance; reduced number of product and process non-conformances; greater employee

  8. Water hammer caused by closure of turbine safety spherical valves

    Science.gov (United States)

    Karadžić, U.; Bergant, A.; Vukoslavčević, P.

    2010-08-01

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perućica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  9. Water hammer caused by closure of turbine safety spherical valves

    International Nuclear Information System (INIS)

    Karadzic, U; Vukoslavcevic, P; Bergant, A

    2010-01-01

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perucica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  10. Water hammer caused by closure of turbine safety spherical valves

    Energy Technology Data Exchange (ETDEWEB)

    Karadzic, U; Vukoslavcevic, P [Faculty of Mechanical Engineering, University of Montenegro Dzordza Vasingtona nn, Podgorica, 81000 (Montenegro); Bergant, A, E-mail: uros.karadzic@ac.m [LitostrojPower d.o.o., Litostrojska 50, Ljubljana, 1000 (Slovenia)

    2010-08-15

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perucica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  11. PYME y cooperativas ante el reto de la RSE: la nueva ISO 26000 (SMEs and cooperatives confront the challenge of CSR: the new ISO 26000

    Directory of Open Access Journals (Sweden)

    Juan Pablo Landa

    2012-05-01

    Full Text Available Corporate Social Responsibility is a central issue in modern business and a main factor of companies strategies for competitiveness in a global economy . The recent approval of ISO26000 shows this general tendency to introduce social and environmental principles in global governance and organizational behaviour in all kinds of firms, organizations and multinational corporations. This paper offers a critical approach to the effects of ISO 26000 in the small and medium companies, and cooperatives, too. This norm is not focussed on the particularities of this kind of companies and shows some problems when implementing it in SME & social economy organizations. The question which comes up is if there is a necessity to adapt the implementation of ISO 26000 to these particular firms: in which cases and to what limits. La Responsabilidad Social Corporativa es una cuestión central en la economía moderna, y un factor fundamental en las estrategias competitivas de las empresas, en el marco de una economía globalizada. La reciente aprobación de la norma ISO 26000 recoge la tendencia general de introducir principios sociales y medioambientales en el gobierno global y en la organización de todo tipo de empresas, organizaciones y corporaciones multinacionales. Este artículo ofrece un acercamiento crítico a los efectos de la norma ISO 26000 en las PYMEs y cooperativas. Esta norma no contempla las particularidades de este tipo de compañías, y muestra algunos problemas al implantarlas en PYMEs y organizaciones de la economía social. Se cuestiona la necesidad de adaptar la implementación de la norma ISO 26000 a este tipo de organizaciones, en qué casos, y con qué limites.DOWNLOAD THIS PAPER FROM SSRN: http://ssrn.com/abstract=2049865

  12. How to insure quality valve remanufacture

    International Nuclear Information System (INIS)

    Scott, C.F.

    1991-01-01

    The importance of quality valve repair for the power generation industry is an obvious need for both the owner as well as the consumer. Whether valves are repaired in-line, on-site, or at a valve remanufacturing facility, the selection of a vendor is vital to meeting not only stringent quality requirements, but also to meet start-up schedules and budgets. In the past, the rule of thumb was that repair of a valve could cost approximately 50% of the cost of a new valve and still represent a significant savings to the end user. For power generation facilities, the fact that many valves are welded in not only makes repair more economical, but even vital to continuing normal operations. For those items not welded in, long lead times and higher prices for these normally exotic alloys make remanufactured valves even more attractive. However, even as these advantages of remanufacturing are obvious, some repair organizations continue to cut corners to meet profit demands. The result is suspect quality in some valves. This can lead to premature failures, possible reduced generating capacity, unscheduled outages, and even catastrophic results. Therefore, the choice of a repair organization must be made with care. As the author has said, repair is an obvious option, but the procurement should definitely involve more than just price comparisons. Evaluation must place the emphasis on quality and reliability. Several aspects should be thoroughly investigated and documented in the selection process. These include: personnel; equipment/facilities; procedures; and credentials

  13. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  14. A shut-off valve for flexible tubing

    Science.gov (United States)

    Reyburn, W. W.

    1972-01-01

    Design of light weight valve for flexible tubing is described. Valve is hand operated and provides positive sealing in normally closed position. Diagram is provided to show construction of valve. Principles of operation are explained.

  15. Factors influencing left ventricular outflow tract obstruction following a mitral valve-in-valve or valve-in-ring procedure, part 1.

    Science.gov (United States)

    Bapat, Vinnie; Pirone, Francesco; Kapetanakis, Stam; Rajani, Ronak; Niederer, Steven

    2015-10-01

    To determine the factors influencing left ventricular outflow tract (LVOT) area reduction after a mitral valve-in-valve (VIV) or a valve-in-ring (VIR) procedure. Transcatheter heart valves (THVs) are increasingly used in performing a VIV or a VIR procedure in high-risk patients. Although less invasive, a potential complication is LVOT obstruction. However, the factors predisposing to LVOT obstruction are ill defined. To understand the effects of the various factors, the study was carried out in three parts: To understand the effect of VIV and VIR on reduction in LVOT area with special attention to different surgical heart valve (SHV) orientations and depth of THV implant. This was carried out in porcine and cadaver hearts. To quantify aorto-mitral-annular (AMA) angle in 20 patients with or without mitral disease and to derive a static computational model to predict LVOT obstruction. To study the effect of SHV design on LVOT obstruction after VIV. This was carried out as a bench test. LVOT area reduction was similar after VIV irrespective of orientation of the mitral SHV implantation as it pinned open the SHV leaflets. Similar effect was seen after VIR. The degree of LVOT obstruction was partly determined by AMAangle and was inversely proportional. SHV design, ring design, and depth of SPAIEN XT implantation also had effect on LVOT obstruction. A possibility of LVOT obstruction should be considered when performing a VIV and VIR procedure. Type of SHV, flexible ring, less obtuse AMA angle, and depth of SAPIEN XT implant can influence the risk. © 2015 Wiley Periodicals, Inc.

  16. A Systematic Review of Infective Endocarditis in Patients With Bovine Jugular Vein Valves Compared With Other Valve Types.

    Science.gov (United States)

    Sharma, Ashutosh; Cote, Anita T; Hosking, Martin C K; Harris, Kevin C

    2017-07-24

    The aim of this study was to systematically evaluate the incidence of infective endocarditis (IE) in right ventricle-to-pulmonary artery conduits and valves, comparing bovine jugular vein (BJV) valves with all others. Recent evidence suggests that the incidence of IE is higher in patients with congenital heart disease who have undergone implantation of BJV valves in the pulmonary position compared with other valves. Systematic searches of published research were conducted using electronic databases (MEDLINE, Embase, and CINAHL) and citations cross-referenced current to April 2016. Included studies met the following criteria: patients had undergone right ventricle-to-pulmonary artery conduit or percutaneous pulmonary valve implantation, and investigators reported on the type of conduit or valve implanted, method of intervention (surgery or catheter based), IE incidence, and follow-up time. Fifty studies (Levels of Evidence: 2 to 4) were identified involving 7,063 patients. The median cumulative incidence of IE was higher for BJV compared with other valves (5.4% vs. 1.2%; p endocarditis with BJV valves than other types of right ventricle-to-pulmonary artery conduits. There was no difference in the incidence of endocarditis between catheter-based bovine valves and surgically implanted bovine valves, suggesting that the substrate for future infection is related to the tissue rather than the method of implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Survival and freedom from aortic valve-related reoperation after valve-sparing aortic root replacement in 1015 patients.

    Science.gov (United States)

    Kari, Fabian A; Doll, Kai-Nicolas; Hemmer, Wolfgang; Liebrich, Markus; Sievers, Hans-Hinrich; Richardt, Doreen; Reichenspurner, Hermann; Detter, Christian; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm

    2016-04-01

    The aim of this study was to characterize mortality and aortic valve replacement after valve-sparing aortic root replacement (V-SARR) in a multicentre cohort. Between 1994 and 2014, 1015 patients had V-SARR with (n = 288, 28%) or without cusp/commissure repair (n = 727, 72%) at the centres of Lübeck (n = 343, 34%), Stuttgart (n = 346, 34%), Hamburg (n = 109, 11%) and Freiburg (n = 217, 21%), Germany. Comparative survival of an age- and gender-matched general population was calculated. Log-rank tests and multiple logistic regression were used to identify risk factors. The mean follow-up was 5.2 ± 3.9 years. Cumulative follow-up comprised 2933 patient-years. Early survival was 98%. NYHA status and aneurysm size were predictive of death during mid-term follow-up (P = 0.025). Freedom from aortic valve replacement was 90% at 8 years, with the type of V-SARR (root remodelling, David II) being a risk factor (P = 0.015). Bicuspid aortic valve (P = 0.26) and initial valve function (P = 0.4) did not impact reoperation. The need of additional valve repair (cusps/commissures) was not linked to reoperation: freedom from aortic valve replacement at 8 years was 84% if cusp repair was performed versus 90% if V-SARR alone was performed (P = 0.218). Marfan syndrome had no impact on survival or on aortic valve replacement. Mid-term survival of patients after V-SARR is comparable with that of a matched general population. The regurgitant bicuspid aortic valve is a favourable substrate for V-SARR. Prophylactic surgery should be performed before symptoms or large aneurysms are present to achieve optimal mid-term outcomes. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    Science.gov (United States)

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Porcine Tricuspid Valve Anatomy and Human Compatibility: Relevance for Preclinical Validation of Novel Valve Interventions.

    Science.gov (United States)

    Waziri, Farhad; Lyager Nielsen, Sten; Michael Hasenkam, John

    2016-09-01

    Tricuspid regurgitation may be a precursor for heart failure, reduced functional capacity, and poor survival. A human compatible experimental model is required to understand the pathophysiology of the tricuspid valve disease as a basis for validating novel tricuspid valve interventions before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin-fixed porcine hearts obtained from Danish Landrace pigs (body weight 80 kg). All valvular dimensions were compared with human data acquired from literature sources. No difference was seen in the tricuspid annulus circumference between porcine and human hearts (13.0 ± 1.2 cm versus 13.5 ± 1.5 cm; p = NS), or in valve area (5.7 ± 1.6 cm2 versus 5.6 ± 1.0 cm2; p = NS). The majority of chordae types exhibited a larger chordal length and thickness in human hearts compared to porcine hearts. In both species, the anterior papillary muscle (PM) was larger than other PMs in the right ventricle, but muscle length varied greatly (range: 5.2-40.3 mm) and was significantly different in pigs and in humans (12.2 ± 3.2 mm versus 19.2 mm; p human hearts.

  20. Occupational exposures at nuclear power plants. Twelfth annual report of the Isoe programme, 2002

    International Nuclear Information System (INIS)

    2004-01-01

    The Information System on Occupational Exposure (ISOE) was created by the OECD Nuclear Energy Agency in 1992 to promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The ISOE Programme provides experts in occupational radiation protection with a forum for communication and exchange of experience. The ISOE databases enable the analysis of occupational exposure data from the 465 commercial nuclear power plants participating in the Programme (representing some 90 per cent of the world's total operating commercial reactors). The Twelfth Annual Report of the ISOE Programme summarises achievements made during 2002 and compares annual occupational exposure data. Principal developments in ISOE participating countries are also described. (author)

  1. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  2. Assessment of structural valve deterioration of transcatheter aortic bioprosthetic balloon-expandable valves using the new European consensus definition.

    Science.gov (United States)

    Eltchaninoff, Hélène; Durand, Eric; Avinée, Guillaume; Tron, Christophe; Litzler, Pierre-Yves; Bauer, Fabrice; Dacher, Jean-Nicolas; Werhlin, Camille; Bouhzam, Najime; Bettinger, Nicolas; Candolfi, Pascal; Cribier, Alain

    2018-03-30

    Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.

  3. NRC Information No. 90-21: Potential failure of motor-operated butterfly valves to operate because valve seat friction was underestimated

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1992-01-01

    In October 1988, at Catawba Nuclear Station Unit 1, a motor-operated butterfly valve in the service water system failed to open under high differential pressure conditions. The licensee concluded that the valve manufacturer, BIF/General Signal Corporation, had underestimated the degree to which the material used in the valve seat would harden with age (the responsibility for these valves has been transferred to Paul-Munroe Enertech). This underestimation of the age hardening had led the manufacturer to assume valve seat friction forces that were less than the actual friction forces in the installed valve. To overcome the larger-than-anticipated friction forces, the licensee's engineering staff recommended the open torque switch for 56 butterfly valves be reset to the maximum allowable value. The systems in which these valves are located include the component cooling water system, service water system, and various ventilation systems. By July 26, 1989, the torque switch adjustments were completed at Catawba Units 1 and 2. After reviewing the final settings, the licensee's engineering staff determined that the actuators for three butterfly valves in the component cooling water system might not be able to overcome the friction forces resulting from maximum seat hardening. On December 13, 1989, the licensee determined that the failure of these BIF/General Signal motor-operated valves (MOVs) could cause a loss of cooling water to residual heat removal system heat exchangers. To resolve the concern regarding the operability of these BIF/General Signal valves, a torque switch bypass was installed on two of the actuators to allow full motor capability during opening

  4. ISO 50001 for US Commercial Buildings - Current Status and Opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jingjing; Sheaffer, Paul

    2017-12-01

    ''ISO 50001: 2011 Energy management systems – Requirements with guidance for use'' is a voluntary International Standard which provides organizations a proven framework to manage energy and continuously improve their energy performance. Implementing ISO 50001 in the commercial building sector has its unique opportunities and challenges in comparison with the industrial sector. The energy footprint of a portfolio of commercial buildings can be just as significant as a large industrial facility in comparison. There are many energy-saving opportunities in commercial buildings that can be addressed without capital investments, and the perceived risks for making energy improvements can be lower than in the industrial sector. In addition, the energy-consuming systems in commercial buildings are limited in types and have many similarities across buildings, which makes it much easier to standardize many ISO 50001 required processes, 5 procedures and documents to simplify implementation. There are also some sector-unique challenges, such as less familiar with ISO systems and the certification process. Another challenge arises from the complexity in some buildings’ ownership, tenancy, and O&M responsibilities. This whitepaper discusses these opportunities and issues in detail. The paper also recommends the characteristics of organizations in the commercial building sector that can benefit the most from adopting the ISO 50001 standard – namely the “suitable market”. Eight segments (education, food sales, retail, inpatient health care, hospitality, office buildings, laboratories and data centers) within the commercial building sector are highlighted.

  5. The ISO9000 standard in electrical research

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Ortiz, G.; Davila-Nunez, G.; Gonzalez-Sustaeta, J. [Inst. de Investigaciones Electricas, Cuernavaca (Mexico). Unidad de Sistemas Informaticos

    1999-11-01

    In this article, the main aspects that are considered important upon applying the ISO9000 standard [ISO 94] in a research institution, company, or group, are described. The 20 sections of the standard are discussed emphasizing the concepts and definitions that can be differently interpreted in the process of elaboration of a quality manual for a group devoted to research, than when they are applied in the elaboration of a manual for a factory that produces material goods. The exposed reasoning was used in the elaboration of the quality manual in the Information Systems Unit of the Electrical Research Institute in Mexico, and it is being used in the installation and operation of the quality system.

  6. Northwest Boundary Containment/Treatment System Baseline Conditions, System Startup, and Operational Assessment. Volume 1.

    Science.gov (United States)

    1987-12-01

    combination pressure reducing check valve that is manually I controlled. A shutoff valve is installed on each well discharge line to iso - late the well from...system. This profile exhibits a relatively gentle, stable gradient between wells 27003 and 22051 which is due to the alignment of this portion of the...isoconcentration lines. As a result, the iso - 3 concentration maps for this period were constructed using isoconcentration maps for the later years as a

  7. Dysfunction of an On-X Heart Valve by Pannus.

    Science.gov (United States)

    Abad, Cipriano; Urso, Stefano; Gomez, Elsa; De la Vega, Maria

    2016-09-01

    A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute.

  8. Development of Overflow-Prevention Valve with Trigger Mechanism.

    Science.gov (United States)

    Ishino, Yuji; Mizuno, Takeshi; Takasaki, Masaya

    2016-09-01

    A new overflow-prevention valve for combustible fluid is developed which uses a trigger mechanism. Loading arms for combustible fluid are used for transferring oil from a tanker to tanks and vice versa. The loading arm has a valve for preventing overflow. Overflow- prevention valves cannot use any electric component to avoid combustion. Therefore, the valve must be constructed only by mechanical parts. The conventional overflow-prevention valve uses fluid and pneumatic forces. It consists of a sensor probe, a cylinder, a main valve for shutting off the fluid and a locking mechanism for holding an open state of the main valve. The proposed overflow-prevention valve uses the pressure due to the height difference between the fluid level of the tank and the sensor probe. However, the force of the cylinder produced by the pressure is too small to release the locking mechanism. Therefore, a trigger mechanism is introduced between the cylinder and the locking mechanism. The trigger mechanism produces sufficient force to release the locking mechanism and close the main valve when the height of fluid exceeds a threshold value. A trigger mechanism is designed and fabricated. The operation necessary for closing the main valve is conformed experimentally.

  9. Transfemoral Aortic Valve Implantation with the New Edwards Sapien 3 Valve for Treatment of Severe Aortic Stenosis-Impact of Valve Size in a Single Center Experience.

    Directory of Open Access Journals (Sweden)

    Jochen Wöhrle

    Full Text Available The third generation Edwards Sapien 3 (Edwards Lifesciences Inc., Irvine, California system was optimized to reduce residual aortic regurgitation and vascular complications.235 patients with severe symptomatic aortic stenosis were prospectively enrolled. Transcatheter aortic valve implantations (TAVI were performed without general anesthesia by transfemoral approach. Patients were followed for 30 days. Patients received 23mm (N = 77, 26mm (N = 91 or 29mm (N = 67 valve based on pre-procedural 256 multislice computer tomography. Mean oversizing did not differ between the 3 valves. There was no residual moderate or severe aortic regurgitation. Rate of mild aortic regurgitation and regurgitation index did not differ between groups. There was no switch to general anesthesia or conversion to surgery. Rate of major vascular complication was 3.0% with no difference between valve and delivery sheath sizes. Within 30 days rates of all cause mortality (2.6% and stroke (2.1% were low.In patients with severe aortic stenosis transfemoral TAVI with the Edwards Sapien 3 valve without general anesthesia was associated with a high rate of device success, no moderate or severe residual aortic regurgitation, low rates of major vascular complication, mortality and stroke within 30 days with no difference between the 3 valve sizes.ClinicalTrials.gov NCT02162069.

  10. The use of transcatheter aortic valve replacement vs surgical aortic valve replacement for the treatment of aortic stenosis

    Directory of Open Access Journals (Sweden)

    Jensen HA

    2015-08-01

    Full Text Available Hanna A Jensen, Lillian L Tsai, Vinod H Thourani Division of Cardiothoracic Surgery, Joseph B Whitehead Department of Surgery, Structural Heart and Valve Center, Emory University School of Medicine, Atlanta, GA, USA Abstract: Severe aortic stenosis (AS is associated with considerable morbidity and mortality and is increasing in prevalence as the global population increases. Since AS primarily affects the elderly, many of these patients have comorbidities that make them poor candidates for the gold standard treatment for AS, surgical aortic valve replacement. Transcatheter aortic valve replacement has emerged as a novel technology for the management of AS in higher risk patients over the past decade. Randomized trials have established the safety and efficacy of transcatheter aortic valve replacement, and the medical community has rallied to identify the patients who are most suitable for this transformative treatment. This review focuses on outlining the key procedural differences, describing the unique challenges of both operations, and finally assessing and comparing outcomes both on a general level and in challenging patient subgroups. Keywords: aortic valve replacement, transcatheter aortic valve replacement, surgical aortic valve replacement 

  11. Sustainable development induction in organizations: a convergence analysis of ISO standards management tools' parameters.

    Science.gov (United States)

    Merlin, Fabrício Kurman; Pereira, Vera Lúciaduarte do Valle; Pacheco, Waldemar

    2012-01-01

    Organizations are part of an environment in which they are pressured to meet society's demands and acting in a sustainable way. In an attempt to meet such demands, organizations make use of various management tools, among which, ISO standards are used. Although there are evidences of contributions provided by these standards, it is questionable whether its parameters converge for a possible induction for sustainable development in organizations. This work presents a theoretical study, designed on structuralism world view, descriptive and deductive method, which aims to analyze the convergence of management tools' parameters in ISO standards. In order to support the analysis, a generic framework for possible convergence was developed, based on systems approach, linking five ISO standards (ISO 9001, ISO 14001, OHSAS 18001, ISO 31000 and ISO 26000) with sustainable development and positioning them according to organization levels (strategic, tactical and operational). The structure was designed based on Brundtland report concept. The analysis was performed exploring the generic framework for possible convergence based on Nadler and Tushman model. The results found the standards can contribute to a possible sustainable development induction in organizations, as long as they meet certain minimum conditions related to its strategic alignment.

  12. KSC Center Director Bridges accepts an ISO 9001 certification plaque from DNV

    Science.gov (United States)

    1998-01-01

    Center Director Roy Bridges (right) displays the 2000th ISO Certificate Plaque he was given by Dalton Lyon (left) of Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. The plaque is a representation of the ISO 9001 certification awarded to KSC by DNV. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world- class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification.

  13. Step of quality assurance preparation on ISO 9001:2000 toward certification

    International Nuclear Information System (INIS)

    Agustiar

    2007-01-01

    ISO 9001:2000 is the International Standard for the quality management system that stipulate requirement and recommendation provided for design until product. The standard is also regulated the implementation and evaluation from management system point of view the objective to assure organization will meet specified requirement product. To propose ISO 9001:2000 certification, many steps of action should be carried out. There are 5 primary sections of the quality management system requirements of ISO 9001:2000. Quality Management system, Management responsibility, Resource management, Product realization and Measurement, Analysis and improvement, in which all will be begun with training until evaluation (author)

  14. Surgery for rheumatic mitral valve disease in sub-saharan African countries: why valve repair is still the best surgical option.

    Science.gov (United States)

    Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie

    2016-01-01

    Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.

  15. Magnon Valve Effect between Two Magnetic Insulators

    Science.gov (United States)

    Wu, H.; Huang, L.; Fang, C.; Yang, B. S.; Wan, C. H.; Yu, G. Q.; Feng, J. F.; Wei, H. X.; Han, X. F.

    2018-03-01

    The key physics of the spin valve involves spin-polarized conduction electrons propagating between two magnetic layers such that the device conductance is controlled by the relative magnetization orientation of two magnetic layers. Here, we report the effect of a magnon valve which is made of two ferromagnetic insulators (YIG) separated by a nonmagnetic spacer layer (Au). When a thermal gradient is applied perpendicular to the layers, the inverse spin Hall voltage output detected by a Pt bar placed on top of the magnon valve depends on the relative orientation of the magnetization of two YIG layers, indicating the magnon current induced by the spin Seebeck effect at one layer affects the magnon current in the other layer separated by Au. We interpret the magnon valve effect by the angular momentum conversion and propagation between magnons in two YIG layers and conduction electrons in the Au layer. The temperature dependence of the magnon valve ratio shows approximately a power law, supporting the above magnon-electron spin conversion mechanism. This work opens a new class of valve structures beyond the conventional spin valves.

  16. Flowfield Analysis of a Pneumatic Solenoid Valve

    Directory of Open Access Journals (Sweden)

    Sheam-Chyun Lin

    2018-07-01

    Full Text Available Pneumatic solenoid valve has been widely used in the vehicle control systems for meeting the rapid-reaction demand triggered by the dynamic conditions encountered during the driving course of vehicle. For ensuring the safety of human being, the reliable and effective solenoid valve is in great demand to shorten the reaction time and thus becomes the topic of this research. This numerical study chooses a commercial 3/2-way solenoid valve as the reference valve for analysing its performance. At first, CFD software Fluent is adopted to simulate the flow field associated with the valve configuration. Then, the comprehensive flow visualization is implemented to identify the locations of adverse flow patterns. Accordingly, it is found that a high-pressure region exists in the zone between the nozzle exit and the top of iron core. Thereafter, the nozzle diameter and the distance between nozzle and spool are identified as the important design parameters for improving the pressure response characteristics of valve. In conclusion, this work establishes a rigorous and systematic CFD scheme to evaluate the performance of pneumatic solenoid valve.

  17. Predicting the quantifiable impacts of ISO 50001 on climate change mitigation

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee; Therkelsen, Peter; Scodel, Anna; Rao, Prakash; Aghajanzadeh, Arian; Hirzel, Simon; Zhang, Ruiqin; Prem, Richard; Fossa, Alberto; Lazarevska, Ana M.; Matteini, Marco; Schreck, Bettina; Allard, Fabian; Villegal Alcántar, Noé; Steyn, Karel; Hürdoğan, Ertaç; Björkman, Thomas; O' Sullivan, John

    2017-08-01

    The ISO 50001-Energy management standard provides a continual improvement framework for organizations to reduce their energy consumption, which in the industrial and commercial (service) sectors, accounts for nearly 40% of global greenhouse gas emissions. Reducing this energy consumption will be critical for countries to achieve their national greenhouse gas reduction commitments. Several national policies already support ISO 50001; however, there is no transparent, consistent process to estimate the potential impacts of its implementation. This paper presents the ISO 50001 Impacts Methodology, an internationally-developed methodology to calculate these impacts at a national, regional, or global scale suitable for use by policymakers. The recently-formed ISO 50001 Global Impacts Research Network provides a forum for policymakers to refine and encourage use of the methodology. Using this methodology, a scenario with 50% of projected global industrial and service sector energy consumption under ISO 50001 management by 2030 would generate cumulative primary energy savings of approximately 105 EJ, cost savings of nearly US $700 billion (discounted to 2016 net present value), and 6500 million metric tons (Mt) of avoided CO2 emissions. The avoided annual CO2 emissions in 2030 alone are equivalent to removing 210 million passenger vehicles from the road.

  18. Branched polynomial covering maps

    DEFF Research Database (Denmark)

    Hansen, Vagn Lundsgaard

    2002-01-01

    A Weierstrass polynomial with multiple roots in certain points leads to a branched covering map. With this as the guiding example, we formally define and study the notion of a branched polynomial covering map. We shall prove that many finite covering maps are polynomial outside a discrete branch ...... set. Particular studies are made of branched polynomial covering maps arising from Riemann surfaces and from knots in the 3-sphere. (C) 2001 Elsevier Science B.V. All rights reserved.......A Weierstrass polynomial with multiple roots in certain points leads to a branched covering map. With this as the guiding example, we formally define and study the notion of a branched polynomial covering map. We shall prove that many finite covering maps are polynomial outside a discrete branch...

  19. Leakage characterization of a piloted power operated relief valve

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Hess, M.D.

    1995-01-01

    In Westinghouse Pressurized Water Reactors (PWRs), power operated relief valves (PORVs) are used to provide overpressure protection of the Pressurizer. The valves are fail closed globe valves which means that power is required to open the valves and, on loss of power, the valves close. There are two ways to operate the PORVs. The more common way is to directly couple the disc to an actuator via a disc-stem assembly. The type of design is not the object of this paper. The other and less common way of operating a PORV is by piloting the main valve such that the opening or closing of a pilot valve opens and closes the main valve. This is the design of interest. In most plants, the PORVs are installed with a water loop seal while in some plants no water loop seals are used. It is generally accepted that loop seal installation minimizes valve seat leakage. In non-loop seal installation, the valve seat is exposed to steam which increases the potential for seat leakage. This paper describes the results of some tests performed with nitrogen and steam to characterize the leakage potential of a pilot operated PORV. The test results were compared with seat leakage tests of check valves to provide insight on the leakage testing of pilot operated valves and check valves. The paper also compares the test data with leakage estimates using the ASME/ANSI OM Code guidance on valve leakage

  20. Classification of heart valve condition using acoustic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Prosthetic heart valves and the many great strides in valve design have been responsible for extending the life spans of many people with serious heart conditions. Even though the prosthetic valves are extremely reliable, they are eventually susceptible to long-term fatigue and structural failure effects expected from mechanical devices operating over long periods of time. The purpose of our work is to classify the condition of in vivo Bjork-Shiley Convexo-Concave (BSCC) heart valves by processing acoustic measurements of heart valve sounds. The structural failures of interest for Bscc valves is called single leg separation (SLS). SLS can occur if the outlet strut cracks and separates from the main structure of the valve. We measure acoustic opening and closing sounds (waveforms) using high sensitivity contact microphones on the patient`s thorax. For our analysis, we focus our processing and classification efforts on the opening sounds because they yield direct information about outlet strut condition with minimal distortion caused by energy radiated from the valve disc.