WorldWideScience

Sample records for iso reference model

  1. Integrating nursing diagnostic concepts into the medical entities dictionary using the ISO Reference Terminology Model for Nursing Diagnosis.

    Science.gov (United States)

    Hwang, Jee-In; Cimino, James J; Bakken, Suzanne

    2003-01-01

    The purposes of the study were (1) to evaluate the usefulness of the International Standards Organization (ISO) Reference Terminology Model for Nursing Diagnoses as a terminology model for defining nursing diagnostic concepts in the Medical Entities Dictionary (MED) and (2) to create the additional hierarchical structures required for integration of nursing diagnostic concepts into the MED. The authors dissected nursing diagnostic terms from two source terminologies (Home Health Care Classification and the Omaha System) into the semantic categories of the ISO model. Consistent with the ISO model, they selected Focus and Judgment as required semantic categories for creating intensional definitions of nursing diagnostic concepts in the MED. Because the MED does not include Focus and Judgment hierarchies, the authors developed them to define the nursing diagnostic concepts. The ISO model was sufficient for dissecting the source terminologies into atomic terms. The authors identified 162 unique focus concepts from the 266 nursing diagnosis terms for inclusion in the Focus hierarchy. For the Judgment hierarchy, the authors precoordinated Judgment and Potentiality instead of using Potentiality as a qualifier of Judgment as in the ISO model. Impairment and Alteration were the most frequently occurring judgments. Nursing care represents a large proportion of health care activities; thus, it is vital that terms used by nurses are integrated into concept-oriented terminologies that provide broad coverage for the domain of health care. This study supports the utility of the ISO Reference Terminology Model for Nursing Diagnoses as a facilitator for the integration process.

  2. Mapping VIPS Concepts for Nursing Interventions to the ISO Reference Terminology Model for Nursing Actions: A Collaborative Scandinavian Analysis

    DEFF Research Database (Denmark)

    Lauge Berring, Lene; Ehnfors, Margareta; Angermo, Lilly

    2005-01-01

    The aims of this study were to analyze the coherence between the concepts for nursing interventions in the Swedish VIPS model for nursing recording and the ISO Reference Terminology Model for Nursing Actions and to identify areas in the two models for further development. Seven Scandinavian experts...

  3. Integrating Nursing Diagnostic Concepts into the Medical Entities Dictionary Using the ISO Reference Terminology Model for Nursing Diagnosis

    OpenAIRE

    Hwang, Jee-In; Cimino, James J.; Bakken, Suzanne

    2003-01-01

    Objective: The purposes of the study were (1) to evaluate the usefulness of the International Standards Organization (ISO) Reference Terminology Model for Nursing Diagnoses as a terminology model for defining nursing diagnostic concepts in the Medical Entities Dictionary (MED) and (2) to create the additional hierarchical structures required for integration of nursing diagnostic concepts into the MED.

  4. Mapping VIPS concepts for nursing interventions to the ISO reference terminology model for nursing actions: A collaborative Scandinavian analysis

    DEFF Research Database (Denmark)

    Ehnfors, Margareta; Angermo, Lilly Marit; Berring, Lene

    2006-01-01

    analyzed the VIPS model's concepts for nursing interventions using prototypical examples of nursing actions, involving 233 units of analyses, and collaborated in mapping the two models. All nursing interventions in the VIPS model comprise actions and targets, but a few lack explicit expressions of means......The aims of this study were to analyze the coherence between the concepts for nursing interventions in the Swedish VIPS model for nursing recording and the ISO Reference Terminology Model for Nursing Actions and to identify areas in the two models for further development. Seven Scandinavian experts....... In most cases, the recipient of care is implicit. Expressions for the aim of an action are absent from the ISO model. By this mapping we identified areas for future development of the VIPS model and the experience from nursing terminology work in Scandinavia can contribute to the international...

  5. 16 CFR Figure 2 to Part 1203 - ISO Headform-Basic, Reference, and Median Planes

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false ISO Headform-Basic, Reference, and Median Planes 2 Figure 2 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT... Headform-Basic, Reference, and Median Planes ER10MR98.002 ...

  6. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    Energy Technology Data Exchange (ETDEWEB)

    Burns, R.E. Jr.; O`Brien, J.M. Jr. [Atlan-Tech, Rosewll, GA (United States)

    1993-12-31

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison.

  7. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    International Nuclear Information System (INIS)

    Burns, R.E. Jr.; O'Brien, J.M. Jr.

    1993-01-01

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison

  8. ISO radiation protection standards

    International Nuclear Information System (INIS)

    Becker, K.; West, N.

    1981-01-01

    After a brief description of the International Organization for Standardization (ISO) and its Technical Committee (TC) 85 ''Nuclear Energy'', the work of its Sub-Committee (SC) 2 ''Radiation Protection'' is described in some detail. Several international standards on subjects closely related to radiation protection have already been published, for example ISO-361 (Basic radiation protection symbol), ISO-1757 (Photographic dosimeters), ISO-1758 and 1759 (Direct and indirect-reading pocket exposure meters), ISO-2889 (Sampling of airborne radioactive materials), ISO-4037 (X and gamma reference radiations for calibration) and ISO-4071 (Testing of exposure meters and dosimeters). TC 85/SC 2 has currently eight active Working Groups (WG) dealing with 14 standards projects, mostly in advanced stages, in such fields as neutron and beta reference radiations, and X and gamma radiations of high and low dose-rates and high energies for calibration purposes, reference radiations for surface contamination apparatus, ejection systems for gamma radiography apparatus, industrial and laboratory irradiators, lead shielding units, protective clothing, thermoluminescence dosemeters, radioelement gauges, and surface contamination and decontamination. (author)

  9. A comprehensive iso-octane combustion model with improved thermochemistry and chemical kinetics

    KAUST Repository

    Atef, Nour

    2017-02-05

    Iso-Octane (2,2,4-trimethylpentane) is a primary reference fuel and an important component of gasoline fuels. Moreover, it is a key component used in surrogates to study the ignition and burning characteristics of gasoline fuels. This paper presents an updated chemical kinetic model for iso-octane combustion. Specifically, the thermodynamic data and reaction kinetics of iso-octane have been re-assessed based on new thermodynamic group values and recently evaluated rate coefficients from the literature. The adopted rate coefficients were either experimentally measured or determined by analogy to theoretically calculated values. Furthermore, new alternative isomerization pathways for peroxy-alkyl hydroperoxide (ȮOQOOH) radicals were added to the reaction mechanism. The updated kinetic model was compared against new ignition delay data measured in rapid compression machines (RCM) and a high-pressure shock tube. These experiments were conducted at pressures of 20 and 40 atm, at equivalence ratios of 0.4 and 1.0, and at temperatures in the range of 632–1060 K. The updated model was further compared against shock tube ignition delay times, jet-stirred reactor oxidation speciation data, premixed laminar flame speeds, counterflow diffusion flame ignition, and shock tube pyrolysis speciation data available in the literature. Finally, the updated model was used to investigate the importance of alternative isomerization pathways in the low temperature oxidation of highly branched alkanes. When compared to available models in the literature, the present model represents the current state-of-the-art in fundamental thermochemistry and reaction kinetics of iso-octane; and thus provides the best prediction of wide ranging experimental data and fundamental insights into iso-octane combustion chemistry.

  10. Study on an ISO 15926 based data modeling methodology for nuclear power industry

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Yang Ho; Park, Byeong Ho; Park, Seong Chan; Kim, Eun Kee [KEPCO E-C, Yongin (Korea, Republic of)

    2014-10-15

    The scope is therefore data integration and data to support the whole life of a plant. This representation is specified by a generic, conceptual Data Model (DM) that is independent of any particular application, but that is able to record data from the applications used in plant design, fabrication and operation. The data model is designed to be used in conjunction with Reference Data (RD): standard instances of the DM that represent information common to a number of users, plants, or both. This paper introduces a high level description of the structure of ISO 15926 and how this can be adapted to the nuclear power plant industry in particular. This paper introduces ISO 15926 methodology and how to extend the existing RDL for nuclear power industry. As the ISO 15926 representation is independent of applications, interfaces to existing or future applications have to be developed. Such interfaces are provided by Templates that takes input from external sources and 'lifts' it into an ISO 15926 repository, and/or 'lowers' the data into other applications. This is a similar process to the process defined by W3C. Data exchange can be done using e.g. XML messages, but the modelling is independent of technology used for the exchange.

  11. Energy care in relation to your management system. Linking lists between the Reference Energy Care and ISO 14001, ISO 9001 and HACCP; Energiezorg in relatie tot uw zorgsysteem. Linking lists tussen de Referentie Energiezorg en ISO 14001, ISO 9001 en HACCP

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Several so-called care systems are in use at institutes and companies. For efficiency reasons it makes sense to integrate an energy care system to the existing care system. For the so-called Reference Energy Care, developed by the Netherlands Agency for Energy and the Environment (Novem) links to three of the most important care systems have been elaborated: environmental care according to ISO 14001, the quality care system ISO 9001:2000 and the food safety system Hazard Analysis Critical Control Points (HACCP). The elaboration resulted in three tables, indicating the connections ('linking lists') between each of those care systems and the Reference Energy Care system and how energy care can be integrated into those systems. [Dutch] Bij instellingen en bedrijven zijn diverse zorgsystemen in gebruik. Het is zinvol om energiezorg - waar mogelijk - in een dergelijk bestaand systeem op te nemen. Meerdere zorgsystemen naast elkaar in stand houden is minder efficient dan de systemen integreren tot een systeem. Novem heeft daarom voor haar Referentie Energiezorg de link laten uitwerken naar drie van de meest voorkomende systemen: milieuzorg volgens ISO 14001, het kwaliteitszorgsysteem ISO 9001:2000 en het voedselveiligheidssysteem HACCP (Hazard Analysis Critical Control Points). Hieruit zijn drie tabellen voortgekomen, die aangeven welke verbanden er zijn tussen elk van deze zorgsystemen en de Referentie Energiezorg en hoe u energiezorg kunt integreren in elk van deze systemen. Deze tabellen worden aangeduid als 'linking lists' en u kunt ze gebruiken als hulpmiddel bij het integreren van energiezorg in uw eigen zorgsysteem. U vindt ze in deze brochure.

  12. Energy care in relation to your management system. Linking lists between the Reference Energy Care and ISO 14001, ISO 9001 and HACCP; Energiezorg in relatie tot uw zorgsysteem. Linking lists tussen de Referentie Energiezorg en ISO 14001, ISO 9001 en HACCP

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Several so-called care systems are in use at institutes and companies. For efficiency reasons it makes sense to integrate an energy care system to the existing care system. For the so-called Reference Energy Care, developed by the Netherlands Agency for Energy and the Environment (Novem) links to three of the most important care systems have been elaborated: environmental care according to ISO 14001, the quality care system ISO 9001:2000 and the food safety system Hazard Analysis Critical Control Points (HACCP). The elaboration resulted in three tables, indicating the connections ('linking lists') between each of those care systems and the Reference Energy Care system and how energy care can be integrated into those systems. [Dutch] Bij instellingen en bedrijven zijn diverse zorgsystemen in gebruik. Het is zinvol om energiezorg - waar mogelijk - in een dergelijk bestaand systeem op te nemen. Meerdere zorgsystemen naast elkaar in stand houden is minder efficient dan de systemen integreren tot een systeem. Novem heeft daarom voor haar Referentie Energiezorg de link laten uitwerken naar drie van de meest voorkomende systemen: milieuzorg volgens ISO 14001, het kwaliteitszorgsysteem ISO 9001:2000 en het voedselveiligheidssysteem HACCP (Hazard Analysis Critical Control Points). Hieruit zijn drie tabellen voortgekomen, die aangeven welke verbanden er zijn tussen elk van deze zorgsystemen en de Referentie Energiezorg en hoe u energiezorg kunt integreren in elk van deze systemen. Deze tabellen worden aangeduid als 'linking lists' en u kunt ze gebruiken als hulpmiddel bij het integreren van energiezorg in uw eigen zorgsysteem. U vindt ze in deze brochure.

  13. Modelovanje georeferenciranih podataka u katastru nepokretnosti primenom ISO 19100 serije standarda / Spatial data modeling in the real estate cadastre using ISO 19100 series of standards

    Directory of Open Access Journals (Sweden)

    Mirko N. Petrović

    2010-01-01

    Full Text Available Potreba za standardizacijom u oblasti geografskih informacionih sistema odavno postoji. Međunarodne aktivnosti na ovom polju rezultirale su uspostavljanjem ISO 19100 serije standarda, kojima se regulišu različiti aspekti na polju geoinformatike. U članku su opisane mogućnosti primene relevantnih standarda iz serije ISO 19100 u modelovanju georeferenciranih podataka za katastar nepokretnosti. / Introduction Standardization in geo-information technologies contributes to the establishment of efficient information functions, their greater stability and easier transition. Application of international, national and internal standards in the process of developing software products in the field of geo-information technology creates conditions for the development of efficient, low cost, reliable and secure software products. Spatial data modeling basics for real estate cadastre In terms of modeling, the spatial information of real estate cadastre is based on the vector data model which is suitable for modeling objects with a smaller number of properties with emphasis on the position. The vector spatial data model consists of two components: spatial and descriptive. The basis of the spatial one is geometry that contains metric data usually given in coordinates of a reference system. Geometry and Topology uniquely determine the shape, size and position of the object model in space, i.e. they represent its spatial component. Merging the spatial component with the descriptive one results in a completely defined object from the real world. Elements of spatial data quality Spatial data quality can be reviewed through a set of the following elements: origin, positional accuracy, attribute accuracy, completeness, logical consistency, semantic accuracy and the time information. The elements of spatial data quality listed above are provided using ISO 19100 series of standards. Application of ISO19100 series of standards in spatial data modeling for real

  14. On the suitability of ISO 16717-1 reference spectra for rating airborne sound insulation.

    Science.gov (United States)

    Mašović, Draško B; Pavlović, Dragana S Šumarac; Mijić, Miomir M

    2013-11-01

    A standard proposal for rating airborne sound insulation in buildings [ISO 16717-1 (2012)] defines the reference noise spectra. Since their shapes influence the calculated values of single-number descriptors, reference spectra should approximate well typical noise spectra in buildings. There is, however, very little data in the existing literature on a typical noise spectrum in dwellings. A spectral analysis of common noise sources in dwellings is presented in this paper, as a result of an extensive monitoring of various noisy household activities. Apart from music with strong bass content, the proposed "living" reference spectrum overestimates noise levels at low frequencies.

  15. ADOPTION OF ISO 9001 QUALITY MANAGEMENT STANDARD IN AFRICA

    Directory of Open Access Journals (Sweden)

    Erlantz Allur

    2014-03-01

    Full Text Available This article analyzes the dissemination of ISO 9001, the main global management standards, within Africa. The work refers to the diffusion of ISO 9001 standard in terms of its certification intensity. In this article, the dissemination of ISO 9001 in Africa has been analyzed. The findings reveal that the diffusion of the standard in this continent is not very relevant, what might be seen as an indicator of the process of Africa's trade marginalization in the age of globalization. The general certification intensity of the continet is of 0.18; in other words, the proportion of the contribution of Africa to the global GDP of the world is more than five times superior to the proportion of ISO 9001 certificates located in Africa. By means of the logistic model the dissemination of ISO 9001 is forecasted, and it has been observed that the diffusion of ISO 9001 in Africa is in an 85% of its saturation point. Taking into account this model, it's expected that the dissemination of ISO 9001 will be growing until 2020.

  16. Evaluation of the Reference Numerical Parameters of the Monthly Method in ISO 13790 Considering S/V Ratio

    Directory of Open Access Journals (Sweden)

    Hee-Jeong Kwak

    2015-01-01

    Full Text Available Many studies have investigated the accuracy of the numerical parameters in the application of the quasi steady-state calculation method. The aim of this study is to derive the reference numerical parameters of the ISO 13790 monthly method by reflecting the surface-to-volume (S/V ratio and the characteristics of the structures. The calculation process was established, and the parameters necessary to derive the reference numerical parameters were calculated based on the input data prepared for the established calculation processes. The reference numerical parameters were then derived through regression analyses of the calculated parameters and the time constant. The parameters obtained from an apartment building and the parameters of the international standard were both applied to the Passive House Planning Package (PHPP and EnergyPlus programs, and the results were analyzed in order to evaluate the validity of the results. The analysis revealed that the calculation results based on the parameters derived from this study yielded lower error rates than those based on the default parameters in ISO 13790. However, the differences were shown to be negligible in the case of high heat capacity.

  17. Analysis of the procedures and criteria for implantation of X-ray beams for ISO 4037 reference at low energies

    International Nuclear Information System (INIS)

    Figueiredo, Marcus Tadeu Tanuri de

    2012-01-01

    According to the radiological protection principles, practices involving ionizing radiation must be planned and carried out under the guarantee that the values of individual doses, the number of people exposed to radiation and the probability of accidental exposures are as low as reasonably achievable. Therefore, radiation dosimetry is required to be done with reliable instruments designed for measuring dosimetric quantities. The reliability of the dosimetry depends on both the calibration of the dosimeter and its proper performance under certain test conditions. The International Standardization Organization (ISO), in order to promote international standardization and metrological coherency, established sets of reference X-ray beams for dosimeter calibration and typing-test; they are expected to be implemented in metrology laboratories in compliance with specific technical requirements. At low energies there are specific requirements that need to be considered in both the implementation of the reference beams and their use in calibration and testing. The present study is an analysis of the procedures and criteria for ISO 4037 reference radiation implementation, at low energies. In the Dosimeter Calibration Laboratory of the Development Center of Nuclear Technology (LCD / CDTN), experiments were performed for determining the X-ray reference radiation parameters. Alternatives to the usual methods for half-value layer determination were studied. Spectra of reference beams were simulated with software and compared with experimental measurements. Different climatic conditions were reproduced in the Laboratory for analysis of its influence on the determination of the beam parameters. Uncertainties in the measurements of studied parameters were evaluated. According to the ISO 4037 criteria, the low energy X-ray beams were considered to be implemented; they allowed the determination of the conversion coefficients from air kerma to the operational radiation protection

  18. ISO 9000 Quality Management System

    Science.gov (United States)

    Hadjicostas, Evsevios

    The ISO 9000 series describes a quality management system applicable to any organization. In this chapter we present the requirements of the standard in a way that is as close as possible to the needs of analytical laboratories. The sequence of the requirements follows that in the ISO 9001:2008 standard. In addition, the guidelines for performance improvement set out in the ISO 9004 are reviewed. Both standards should be used as a reference as well as the basis for further elaboration.

  19. Risk Assessment References: Documented Literature Search

    Science.gov (United States)

    2012-10-01

    concepts specified in ISO /IEC 27001 and is designed to assist the satisfactory implementation of information security based on a risk management approach...Knowledge of the concepts, models, processes and terminologies described in ISO /IEC 27001 and ISO /IEC 27002 is important for a complete...Standardization ( ISO ). • Section 2.2: national standards for Canada and Australia/New Zealand. Note: Though most of the references in this section are

  20. Food service compliance with ISO 14001 and ISO 22000

    Directory of Open Access Journals (Sweden)

    Laura Lyra Santos

    2012-06-01

    Full Text Available OBJECTIVE: The objective of this study was to assess food service environmental and food safety management systems according to two checklists based on ABNT ISO 22000 and 14001. METHODS: This exploratory and descriptive study investigated a-la-carte food services of the Federal District, Brazil. Two checklists were developed to investigate ISO 14001 and 22000 compliance. A total of 37 food services were selected from the list of the Brazilian Association of Bars and Restaurants by simple random sampling. Checklist results were analyzed according to ANVISA resolution nº 275/2002. RESULTS: Only five food services employed dietitians to supervise meal production. These establishments achieved the highest ISO compliance. However, no establishment had more than 50% ISO 14001 or 22000 compliance. Restaurants showed little concern for the environment and disobeyed waste disposal laws by not separating recyclables from non-recyclables. CONCLUSION: The study food services do not have safe meal production systems, evidenced by non-conformity with the reference standards. Additionally, they do not attempt to reduce the environmental impact of their wastes. Food services supervised by dietitians are better prepared to produce safe foods.

  1. A comprehensive iso-octane combustion model with improved thermochemistry and chemical kinetics

    KAUST Repository

    Atef, Nour; Kukkadapu, Goutham; Mohamed, Samah; Rashidi, Mariam Al; Banyon, Colin; Mehl, Marco; Heufer, Karl Alexander; Nasir, Ehson Fawad; Alfazazi, Adamu; Das, Apurba K.; Westbrook, Charles K.; Pitz, William J.; Lu, Tianfeng; Farooq, Aamir; Sung, Chih-Jen; Curran, Henry J.; Sarathy, Mani

    2017-01-01

    Iso-Octane (2,2,4-trimethylpentane) is a primary reference fuel and an important component of gasoline fuels. Moreover, it is a key component used in surrogates to study the ignition and burning characteristics of gasoline fuels. This paper presents

  2. Iso-scaling in a microcanonical multifragmentation model

    International Nuclear Information System (INIS)

    Raduta, R.; Raduta, H.

    2003-01-01

    A microcanonical multifragmentation model is used to investigate iso-scaling over a broad range of excitation energies, for several values of freeze-out volume and equilibrated sources with masses between 40 and 200 in both primary and asymptotic stages of the decay. It was found that the values of the slope parameters α and β depend on the size and excitation energy of the source and are affected by the secondary decay of primary fragments. It was evidenced that iso-scaling is affected by finite size effects. The evolution of the differences of neutron and proton chemical potentials corresponding to two equilibrated nuclear sources having the same size and different isospin values with temperature and freeze-out volume is presented. (authors)

  3. ISO 9000 and the total quality management models

    OpenAIRE

    Pacios Lozano, Ana Reyes

    1997-01-01

    Establishes the most outstanding differences between the ISO 9000 norms and total quality management as forms or manners of managing quality used in some information services. Compares two models of total quality: European Foundation far Quality Management and Malcolm Baldrige Awards.

  4. A reference model for space data system interconnection services

    Science.gov (United States)

    Pietras, John; Theis, Gerhard

    1993-01-01

    The widespread adoption of standard packet-based data communication protocols and services for spaceflight missions provides the foundation for other standard space data handling services. These space data handling services can be defined as increasingly sophisticated processing of data or information received from lower-level services, using a layering approach made famous in the International Organization for Standardization (ISO) Open System Interconnection Reference Model (OSI-RM). The Space Data System Interconnection Reference Model (SDSI-RM) incorporates the conventions of the OSIRM to provide a framework within which a complete set of space data handling services can be defined. The use of the SDSI-RM is illustrated through its application to data handling services and protocols that have been defined by, or are under consideration by, the Consultative Committee for Space Data Systems (CCSDS).

  5. Analysis of the procedures and criteria for implantation of X-ray beams for ISO 4037 reference at low energies; Analise dos procedimentos e criterios de implantacao de feixes de raios X de referencia ISO 4037 em baixas energias

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, Marcus Tadeu Tanuri de

    2012-07-01

    According to the radiological protection principles, practices involving ionizing radiation must be planned and carried out under the guarantee that the values of individual doses, the number of people exposed to radiation and the probability of accidental exposures are as low as reasonably achievable. Therefore, radiation dosimetry is required to be done with reliable instruments designed for measuring dosimetric quantities. The reliability of the dosimetry depends on both the calibration of the dosimeter and its proper performance under certain test conditions. The International Standardization Organization (ISO), in order to promote international standardization and metrological coherency, established sets of reference X-ray beams for dosimeter calibration and typing-test; they are expected to be implemented in metrology laboratories in compliance with specific technical requirements. At low energies there are specific requirements that need to be considered in both the implementation of the reference beams and their use in calibration and testing. The present study is an analysis of the procedures and criteria for ISO 4037 reference radiation implementation, at low energies. In the Dosimeter Calibration Laboratory of the Development Center of Nuclear Technology (LCD / CDTN), experiments were performed for determining the X-ray reference radiation parameters. Alternatives to the usual methods for half-value layer determination were studied. Spectra of reference beams were simulated with software and compared with experimental measurements. Different climatic conditions were reproduced in the Laboratory for analysis of its influence on the determination of the beam parameters. Uncertainties in the measurements of studied parameters were evaluated. According to the ISO 4037 criteria, the low energy X-ray beams were considered to be implemented; they allowed the determination of the conversion coefficients from air kerma to the operational radiation protection

  6. The Effect of ISO 9001 and the EFQM Model on Improving Hospital Performance: A Systematic Review.

    Science.gov (United States)

    Yousefinezhadi, Taraneh; Mohamadi, Efat; Safari Palangi, Hossein; Akbari Sari, Ali

    2015-12-01

    This study aimed to explore the effect of the International Organization for Standardization (ISO) ISO 9001 standard and the European foundation for quality management (EFQM) model on improving hospital performance. PubMed, Embase and the Cochrane Library databases were searched. In addition, Elsevier and Springer were searched as main publishers in the field of health sciences. We included empirical studies with any design that had used ISO 9001 or the EFQM model to improve the quality of healthcare. Data were collected and tabulated into a data extraction sheet that was specifically designed for this study. The collected data included authors' names, country, year of publication, intervention, improvement aims, setting, length of program, study design, and outcomes. Seven out of the 121 studies that were retrieved met the inclusion criteria. Three studies assessed the EFQM model and four studies assessed the ISO 9001 standard. Use of the EFQM model increased the degree of patient satisfaction and the number of hospital admissions and reduced the average length of stay, the delay on the surgical waiting list, and the number of emergency re-admissions. ISO 9001 also increased the degree of patient satisfaction and patient safety, increased cost-effectiveness, improved the hospital admissions process, and reduced the percentage of unscheduled returns to the hospital. Generally, there is a lack of robust and high quality empirical evidence regarding the effects of ISO 9001 and the EFQM model on the quality care provided by and the performance of hospitals. However, the limited evidence shows that ISO 9001 and the EFQM model might improve hospital performance.

  7. A comprehensive experimental and modeling study of iso-pentanol combustion

    KAUST Repository

    Sarathy, Mani

    2013-12-01

    Biofuels are considered as potentially attractive alternative fuels that can reduce greenhouse gas and pollutant emissions. iso-Pentanol is one of several next-generation biofuels that can be used as an alternative fuel in combustion engines. In the present study, new experimental data for iso-pentanol in shock tube, rapid compression machine, jet stirred reactor, and counterflow diffusion flame are presented. Shock tube ignition delay times were measured for iso-pentanol/air mixtures at three equivalence ratios, temperatures ranging from 819 to 1252. K, and at nominal pressures near 40 and 60. bar. Jet stirred reactor experiments are reported at 5. atm and five equivalence ratios. Rapid compression machine ignition delay data was obtained near 40. bar, for three equivalence ratios, and temperatures below 800. K. Laminar flame speed data and non-premixed extinction strain rates were obtained using the counterflow configuration. A detailed chemical kinetic model for iso-pentanol oxidation was developed including high- and low-temperature chemistry for a better understanding of the combustion characteristics of higher alcohols. First, bond dissociation energies were calculated using ab initio methods, and the proposed rate constants were based on a previously presented model for butanol isomers and n-pentanol. The model was validated against new and existing experimental data at pressures of 1-60. atm, temperatures of 650-1500. K, equivalence ratios of 0.25-4.0, and covering both premixed and non-premixed environments. The method of direct relation graph (DRG) with expert knowledge (DRGX) was employed to eliminate unimportant species and reactions in the detailed mechanism, and the resulting skeletal mechanism was used to predict non-premixed flames. In addition, reaction path and temperature A-factor sensitivity analyses were conducted for identifying key reactions at various combustion conditions. © 2013 The Combustion Institute.

  8. A comprehensive experimental and modeling study of iso-pentanol combustion

    KAUST Repository

    Sarathy, Mani; Park, Sungwoo; Weber, Bryan W.; Wang, Weijing; Veloo, Peter S.; Davis, Alexander C.; Togbé , Casimir; Westbrook, Charles K.; Park, Okjoo; Dayma, Guillaume; Luo, Zhaoyu; Oehlschlaeger, Matthew A.; Egolfopoulos, Fokion N.; Lu, Tianfeng; Pitz, William J.; Sung, Chihjen; Dagaut, P.

    2013-01-01

    Biofuels are considered as potentially attractive alternative fuels that can reduce greenhouse gas and pollutant emissions. iso-Pentanol is one of several next-generation biofuels that can be used as an alternative fuel in combustion engines. In the present study, new experimental data for iso-pentanol in shock tube, rapid compression machine, jet stirred reactor, and counterflow diffusion flame are presented. Shock tube ignition delay times were measured for iso-pentanol/air mixtures at three equivalence ratios, temperatures ranging from 819 to 1252. K, and at nominal pressures near 40 and 60. bar. Jet stirred reactor experiments are reported at 5. atm and five equivalence ratios. Rapid compression machine ignition delay data was obtained near 40. bar, for three equivalence ratios, and temperatures below 800. K. Laminar flame speed data and non-premixed extinction strain rates were obtained using the counterflow configuration. A detailed chemical kinetic model for iso-pentanol oxidation was developed including high- and low-temperature chemistry for a better understanding of the combustion characteristics of higher alcohols. First, bond dissociation energies were calculated using ab initio methods, and the proposed rate constants were based on a previously presented model for butanol isomers and n-pentanol. The model was validated against new and existing experimental data at pressures of 1-60. atm, temperatures of 650-1500. K, equivalence ratios of 0.25-4.0, and covering both premixed and non-premixed environments. The method of direct relation graph (DRG) with expert knowledge (DRGX) was employed to eliminate unimportant species and reactions in the detailed mechanism, and the resulting skeletal mechanism was used to predict non-premixed flames. In addition, reaction path and temperature A-factor sensitivity analyses were conducted for identifying key reactions at various combustion conditions. © 2013 The Combustion Institute.

  9. ISO STANDARD IN THE FIELD OF LEARNING SERVICES AND THE PROSPECT OF ITS APPLICATION IN RUSSIA

    Directory of Open Access Journals (Sweden)

    Galina Pankina

    2015-11-01

    Full Text Available The article considers peculiarities and the prospect of the practical implementation of a rather new standard developed by ISO and adopted in Russia. The objective of ISO 29990:2010 is to provide a generic model for quality professional practice and performance, and a common reference for learning service providers and their clients in the design, development and delivery of non-formal education and training.

  10. A Cross-Country Empirical Study Towards the Impact of Following ISO Management System Standards on Euro-Area Economic Confidence

    Directory of Open Access Journals (Sweden)

    Ştefan Daniel Armeanu

    2017-02-01

    Full Text Available This study aims to examine the impact of following ISO management system standards on economic sentiment indicator (ESI as proxy of economic agents’ general view concerning economic activity, for 21 European Union member states over 2005-2014. The empirical research comprises ISO standards with reference to management systems towards quality (ISO 9001, ISO 13485, ISO 16949, food safety (ISO 22000, environment (ISO 14001, and information security (ISO 27001. Panel data fixed effects regression models provide support for a positive impact of the quality management systems related to automotive industry, as well as information security management systems, on the ESI. Further, dynamic panel data approach by way of two-step system generalized method of moments emphasizes a positive influence of quality management systems standard for the medical device industry on Euro-area economic confidence, but a negative effect of food safety management systems. Also, ISO 9001, ISO 22000, and ISO 14001 Granger cause ESI.

  11. ENVIRONMENTAL RESPONSIBILITY MODEL BASED ON ISO 14000 MANAGEMENT SYSTEMS

    Directory of Open Access Journals (Sweden)

    Catalina SITNIKOV

    2012-01-01

    Full Text Available Worldwide corporations, as well as their stakeholders, are more conscious of the need for environmental management, SR behaviour, and sustainable growth and development. International Standards are becoming more significant for corporations to work towards common environmental management practices. ISO 14001 is the first and the broadest standard intended at a more responsible approach of corporations and the world’s most acknowledged framework for environmental management systems that assists corporations to better manage the effect of their activities on the environment. This article aims to study ISO 14001 implementation and its effects on the environmental responsibility. A model will be built, which covers the environmental management system, the components of organizational culture, being able to influence environmental standards implementation.

  12. Reduced Gasoline Surrogate (Toluene/n-Heptane/iso-Octane) Chemical Kinetic Model for Compression Ignition Simulations

    KAUST Repository

    Sarathy, Mani; Atef, Nour; Alfazazi, Adamu; Badra, Jihad; Zhang, Yu; Tzanetakis, Tom; Pei, Yuanjiang

    2018-01-01

    Toluene primary reference fuel (TPRF) (mixture of toluene, iso-octane and heptane) is a suitable surrogate to represent a wide spectrum of real fuels with varying octane sensitivity. Investigating different surrogates in engine simulations is a prerequisite to identify the best matching mixture. However, running 3D engine simulations using detailed models is currently impossible and reduction of detailed models is essential. This work presents an AramcoMech reduced kinetic model developed at King Abdullah University of Science and Technology (KAUST) for simulating complex TPRF surrogate blends. A semi-decoupling approach was used together with species and reaction lumping to obtain a reduced kinetic model. The model was widely validated against experimental data including shock tube ignition delay times and premixed laminar flame speeds. Finally, the model was utilized to simulate the combustion of a low reactivity gasoline fuel under partially premixed combustion conditions.

  13. Reduced Gasoline Surrogate (Toluene/n-Heptane/iso-Octane) Chemical Kinetic Model for Compression Ignition Simulations

    KAUST Repository

    Sarathy, Mani

    2018-04-03

    Toluene primary reference fuel (TPRF) (mixture of toluene, iso-octane and heptane) is a suitable surrogate to represent a wide spectrum of real fuels with varying octane sensitivity. Investigating different surrogates in engine simulations is a prerequisite to identify the best matching mixture. However, running 3D engine simulations using detailed models is currently impossible and reduction of detailed models is essential. This work presents an AramcoMech reduced kinetic model developed at King Abdullah University of Science and Technology (KAUST) for simulating complex TPRF surrogate blends. A semi-decoupling approach was used together with species and reaction lumping to obtain a reduced kinetic model. The model was widely validated against experimental data including shock tube ignition delay times and premixed laminar flame speeds. Finally, the model was utilized to simulate the combustion of a low reactivity gasoline fuel under partially premixed combustion conditions.

  14. Certification of a reference material for determination of total cyanide in soil to support implementation of the International Standard ISO 11262:2011.

    Science.gov (United States)

    Scharf, Holger; Bremser, Wolfram

    2015-04-01

    Cyanides are among the most important inorganic pollutants to be tested and monitored in environmental compartments. They can be distinguished and determined as free cyanide, weak acid dissociable cyanide or as total cyanide. However, in any case obtained, measurement results are operationally defined referring to the applied analytical method. In 2011, the International Standard ISO 11262 has been published which specifies a normative analytical method for the determination of total cyanide in soil. The objective of the project described in this paper was to provide the first soil reference material (CRM) certified for its mass fraction of total cyanide on the basis of this standard. A total of 12 German laboratories with proven experience in the determination of cyanides in environmental samples participated in the certification study. Measurement results were evaluated in full compliance with the requirements of ISO Guide 35. Taking into account the results of the inter-laboratory comparison as well as the outcome of the homogeneity and stability studies, a certified mass fraction of total cyanide of 21.1 mg/kg and an expanded uncertainty (k = 2) of 1.3 mg/kg were assigned to the material. The reference material has been issued as CRM BAM-U114.

  15. Applying the ISO 9126 Model to the Evaluation of an E-learning System in Iran

    OpenAIRE

    Hossein Pedram; Davood Karimzadegan Moghaddam; Zhaleh Asheghi

    2012-01-01

    One of the models presented in e-learning quality system field is ISO 9126 model, which applied in this research to evaluate e-learning system of Amirkabir University. This model system for evaluation, the six main variables provided that each of these variables by several other indicators was measured. Thus, the model parameters as ISO 9126 and turned the questionnaire survey among samples (120 experts and students of Amirkabir University) and the distribution were completed. Based on the re...

  16. Measuring the Software Product Quality during the Software Development Life-Cycle: An ISO Standards Perspective

    OpenAIRE

    Rafa E. Al-Qutaish

    2009-01-01

    Problem statement: The International Organization for Standardization (ISO) published a set of international standards related to the software engineering, such as ISO 12207 and ISO 9126. However, there is a set of cross-references between the two standards. Approach: The ISO 9126 on software product quality and ISO 12207 on software life cycle processes had been analyzed to invistigate the relationships between them and to make a mapping from the ISO 9126 quality characteristics to the ISO 1...

  17. Definition of a CDI metadata profile and its ISO 19139 based encoding

    Science.gov (United States)

    Boldrini, Enrico; de Korte, Arjen; Santoro, Mattia; Schaap, Dick M. A.; Nativi, Stefano; Manzella, Giuseppe

    2010-05-01

    The Common Data Index (CDI) is the middleware service adopted by SeaDataNet for discovery and query. The primary goal of the EU funded project SeaDataNet is to develop a system which provides transparent access to marine data sets and data products from 36 countries in and around Europe. The European context of SeaDataNet requires that the developed system complies with European Directive INSPIRE. In order to assure the required conformity a GI-cat based solution is proposed. GI-cat is a broker service able to mediate from different metadata sources and publish them through a consistent and unified interface. In this case GI-cat is used as a front end to the SeaDataNet portal publishing the original data, based on CDI v.1 XML schema, through an ISO 19139 application profile catalog interface (OGC CSW AP ISO). The choice of ISO 19139 is supported and driven by INSPIRE Implementing Rules, that have been used as a reference through the whole development process. A mapping from the CDI data model to the ISO 19139 was hence to be implemented in GI-cat and a first draft quickly developed, as both CDI v.1 and ISO 19139 happen to be XML implementations based on the same abstract data model (standard ISO 19115 - metadata about geographic information). This first draft mapping pointed out the CDI metadata model differences with respect to ISO 19115, as it was not possible to accommodate all the information contained in CDI v.1 into ISO 19139. Moreover some modifications were needed in order to reach INSPIRE compliance. The consequent work consisted in the definition of the CDI metadata model as a profile of ISO 19115. This included checking of all the metadata elements present in CDI and their cardinality. A comparison was made with respect to ISO 19115 and possible extensions were individuated. ISO 19139 was then chosen as a natural XML implementation of this new CDI metadata profile. The mapping and the profile definition processes were iteratively refined leading up to a

  18. A graded approach to ISO 9000 implementation for records managers

    Energy Technology Data Exchange (ETDEWEB)

    Pasterczyk, C.E.

    1994-08-01

    ISO 9000 is a series of quality system standards developed by Technical Committee 176 of the International Standards Organization. The series includes three standards, ISO 9001 `Quality systems--Model for quality assurance in design/development, production, installation and serving,` ISO 9002 `Quality systems--Model for quality assurance in production and installation,` ISO 9003 `Quality systems--Model for quality assurance in final inspection and test,` and two guidelines, ISO 9000 `Quality management and quality assurance standards` and ISO 9004 `Quality management and quality system elements--Guidelines.` In companies with quality programs already in place, the structure of the ISO series lends itself to augmenting those policies, procedures, and instructions where problems exist or where the risks of failure are greater. The objectives of this paper are to provide a basic familiarity to ISO 9000 and quality assurance concepts; provide a higher level of familiarity to the records management and document control portions of the ISO 9000 series; and to discuss a graded approach to meeting the intent of ISO 9000.

  19. Experimental and modeling study of the oxidation of n- and iso-butanal

    KAUST Repository

    Veloo, Peter S.; Dagaut, P.; Togbé , Casimir; Dayma, Guillaume; Sarathy, Mani; Westbrook, Charles K.; Egolfopoulos, Fokion N.

    2013-01-01

    Understanding the kinetics of large molecular weight aldehydes is essential in the context of both conventional and alternative fuels. For example, they are key intermediates formed during the low-temperature oxidation of hydrocarbons as well as during the high-temperature oxidation of oxygenated fuels such as alcohols. In this study, an experimental and kinetic modeling investigation of n-butanal (. n-butyraldehyde) and iso-butanal (. iso-butyraldehyde or 2-methylpropanal) oxidation kinetics was performed. Experiments were performed in a jet stirred reactor and in counterflow flames over a wide range of equivalence ratios, temperatures, and pressures. The jet stirred reactor was utilized to observe the evolution of stable intermediates and products for the oxidation of n- and iso-butanal at elevated pressures and low to intermediate temperatures. The counterflow configuration was utilized for the determination of laminar flame speeds. A detailed chemical kinetic interpretative model was developed and validated consisting of 244 species and 1198 reactions derived from a previous study of the oxidation of propanal (propionaldehyde). Extensive reaction pathway and sensitivity analysis was performed to provide detailed insight into the mechanisms governing low-, intermediate-, and high-temperature reactivity. The simulation results using the present model are in good agreement with the experimental laminar flame speeds and well within a factor of two of the speciation data obtained in the jet stirred reactor. © 2013 The Combustion Institute.

  20. Experimental and modeling study of the oxidation of n- and iso-butanal

    KAUST Repository

    Veloo, Peter S.

    2013-09-01

    Understanding the kinetics of large molecular weight aldehydes is essential in the context of both conventional and alternative fuels. For example, they are key intermediates formed during the low-temperature oxidation of hydrocarbons as well as during the high-temperature oxidation of oxygenated fuels such as alcohols. In this study, an experimental and kinetic modeling investigation of n-butanal (. n-butyraldehyde) and iso-butanal (. iso-butyraldehyde or 2-methylpropanal) oxidation kinetics was performed. Experiments were performed in a jet stirred reactor and in counterflow flames over a wide range of equivalence ratios, temperatures, and pressures. The jet stirred reactor was utilized to observe the evolution of stable intermediates and products for the oxidation of n- and iso-butanal at elevated pressures and low to intermediate temperatures. The counterflow configuration was utilized for the determination of laminar flame speeds. A detailed chemical kinetic interpretative model was developed and validated consisting of 244 species and 1198 reactions derived from a previous study of the oxidation of propanal (propionaldehyde). Extensive reaction pathway and sensitivity analysis was performed to provide detailed insight into the mechanisms governing low-, intermediate-, and high-temperature reactivity. The simulation results using the present model are in good agreement with the experimental laminar flame speeds and well within a factor of two of the speciation data obtained in the jet stirred reactor. © 2013 The Combustion Institute.

  1. On the temperature dependence of H-U{sub iso} in the riding hydrogen model

    Energy Technology Data Exchange (ETDEWEB)

    Lübben, Jens; Volkmann, Christian [Institut für Anorganische Chemie, Georg-August-Universität, Tammannstrasse 4, D-37077 Göttingen (Germany); Grabowsky, Simon [School of Chemistry and Biochemistry, Stirling Highway 35, WA-6009 Crawley (Australia); Edwards, Alison [Bragg Institute, Australian Nuclear Science and Technology Organisation, Locked Bag 2001, Kirrawee DC, NSW 2232 (Australia); Morgenroth, Wolfgang [Institut für Geowissenschaften, Abteilung Kristallographie, Goethe-Universität, Altenhöferallee 1, 60438 Frankfurt am Main (Germany); Fabbiani, Francesca P. A. [GZG, Abteilung Kristallographie, Georg-August Universität, Goldschmidtstrasse 1, 37077 Göttingen (Germany); Sheldrick, George M. [Institut für Anorganische Chemie, Georg-August-Universität, Tammannstrasse 4, D-37077 Göttingen (Germany); Dittrich, Birger, E-mail: birger.dittrich@chemie.uni-hamburg.de [Institut für Anorganische und Angewandte Chemie, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Institut für Anorganische Chemie, Georg-August-Universität, Tammannstrasse 4, D-37077 Göttingen (Germany)

    2014-07-01

    The temperature dependence of hydrogen U{sub iso} and parent U{sub eq} in the riding hydrogen model is investigated by neutron diffraction, aspherical-atom refinements and QM/MM and MO/MO cluster calculations. Fixed values of 1.2 or 1.5 appear to be underestimated, especially at temperatures below 100 K. The temperature dependence of H-U{sub iso} in N-acetyl-l-4-hydroxyproline monohydrate is investigated. Imposing a constant temperature-independent multiplier of 1.2 or 1.5 for the riding hydrogen model is found to be inaccurate, and severely underestimates H-U{sub iso} below 100 K. Neutron diffraction data at temperatures of 9, 150, 200 and 250 K provide benchmark results for this study. X-ray diffraction data to high resolution, collected at temperatures of 9, 30, 50, 75, 100, 150, 200 and 250 K (synchrotron and home source), reproduce neutron results only when evaluated by aspherical-atom refinement models, since these take into account bonding and lone-pair electron density; both invariom and Hirshfeld-atom refinement models enable a more precise determination of the magnitude of H-atom displacements than independent-atom model refinements. Experimental efforts are complemented by computing displacement parameters following the TLS+ONIOM approach. A satisfactory agreement between all approaches is found.

  2. The international ISOE programme. ISOE European technical centre activities

    International Nuclear Information System (INIS)

    Ascenzo, L. d'; Crouail, P.; Levy, F.; Livolsi, P.; Schieber, C.; Lefaure, C.

    1996-01-01

    The CEPN has been involved from the beginning in the NEA Information System on Occupational Exposure (ISOE). As ISOE European Technical Centre, the CEPN is responsible for the collection and distribution of European data to the various ISOE partners, the collection of data from the other regional technical centres, and the custodianship of the full ISOE data base. This full data base is updated annually and distributed to all the European participating utilities and to other Regional Technical Centres. The European data are also sent to the European Commission (EC) as a contribution to their own occupational exposure data base. In addition to these activities, the CEPN has developed two computer programmes under Windows to facilitate the management of ISOE data bases. The first software, called ASPIC, allows participating utilities to electronically complete NEA1 and NEA3 questionnaires, as well as to consult the NEA3 data base using key words search routine. This software is available in six different languages. The second programme is a relational data base for the performance of statistical analyses using data from NEA1. The CEPN also contributes significantly to the efficient flow of information through the ISOE Network. This includes participation in the preparation and distribution of the ISOE Annual Report (which presents and analyses NEAI data), ISOE Information Sheets (providing short synthesis using NEA1 and NEA3 data), and Technical Reports. Participating Authorities and Utilities have each made information requests to the CEPN concerning dosimetric data, radiation protection experiences, policies and practices. Some examples of these requests, and of the types of data provided, will be presented. (author)

  3. Integrated management system: The integration of ISO 9001, ISO 14001, OHSAS 18001 and ISO 31000

    Science.gov (United States)

    Muzaimi, Hafizzudin; Chew, Boon Cheong; Hamid, Syaiful Rizal

    2017-03-01

    The implementation of integrated management system (IMS) for better quality management has become a preference for many organizations. This can be seen as many organizations used the combination of quality ISO 9001, an environment ISO 14001 and occupational health and safety management system OHSAS 18001 as a core for the IMS that largely implemented. Besides, the linked between quality management with risk management system need to be identified as the management system that enhance the effectiveness of IMS. Therefore, the risk management system ISO 31000 also presented as a part of integration. In nowadays competitive environment, the increasing pressure and needs from customer or stakeholders make it compulsory for the organization to propose the new system and standards. This paper presents and discusses about the benefit of integration, the management system components that can be converged and the implementation approach. A series of interview was conducted through in-depth interviews with 8 experts in this field, while data collected were analyzed qualitatively. The results consist of 16 factors of IMS implementation that have been identified and the use of PDCA approach for an effective implementation of IMS. As a conclusion, the paper proposes the integration of four management systems (ISO 9001, ISO 14001, OHSAS 18001 and ISO 31000) and on how the IMS can be used to structure the process of management for quality management towards sustainability practices in the organization.

  4. Stability of Kinesthetic Perception in Efferent-Afferent Spaces: The Concept of Iso-perceptual Manifold.

    Science.gov (United States)

    Latash, Mark L

    2018-02-21

    The main goal of this paper is to introduce the concept of iso-perceptual manifold for perception of body configuration and related variables (kinesthetic perception) and to discuss its relation to the equilibrium-point hypothesis and the concepts of reference coordinate and uncontrolled manifold. Hierarchical control of action is postulated with abundant transformations between sets of spatial reference coordinates for salient effectors at different levels. Iso-perceptual manifold is defined in the combined space of afferent and efferent variables as the subspace corresponding to a stable percept. Examples of motion along an iso-perceptual manifold (perceptually equivalent motion) are considered during various natural actions. Some combinations of afferent and efferent signals, in particular those implying a violation of body's integrity, give rise to variable percepts by artificial projection onto iso-perceptual manifolds. This framework is used to interpret unusual features of vibration-induced kinesthetic illusions and to predict new illusions not yet reported in the literature. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  5. ISO27001 / ISO27002 a pocket guide

    CERN Document Server

    Calder, Alan

    2013-01-01

    Information is one of your organisation's most important resources. Keeping it secure is therefore vital to your business. This handy pocket guide is an essential overview of two key information security standards that cover the formal requirements (ISO27001:2013) for creating an Information Security Management System (ISMS), and the best-practice recommendations (ISO27002:2013) for those responsible for initiating, implementing or maintaining it.

  6. Department of Defense Quality Management Systems and ISO 9000:2000

    National Research Council Canada - National Science Library

    Lucius, Tommie

    2002-01-01

    The purpose of the research is to examine and evaluate the emergence of the International Organization for Standardization, commonly referred to as ISO, quality standard for the year 2000 as it applies (past and present...

  7. IsoBank workshop held at IsoEcol10 - University of Tokyo 2016

    OpenAIRE

    Hayden, Brian

    2016-01-01

    IsoBank is a repository for stable isotope values and relevant metadata. These slides were presented at a workshop held during IsoEcol10 to refine and design the IsoBank for the needs of a diverse group of researchers.

  8. Antioxidant mechanisms of iso-6-cassine in suppressing seizures induced by pilocarpine

    Directory of Open Access Journals (Sweden)

    Rivelilson Mendes de Freitas

    2011-06-01

    Full Text Available The aim of this study was to evaluate the in vitro antioxidant effects of 12-[(2R,5R,6R-5-hydroxy-6-methylpiperidin-2-yl]dodecan-2-one (iso-6-cassine; ISO and the anticonvulsant effects of ISO on pilocarpine-induced seizures in rats. Wistar rats were treated with 0.9% saline (i.p., control group, pilocarpine (400 mg/kg, i.p., pilocarpine group, and the association of ISO (1.0 mg/kg, i.p. plus pilocarpine (400 mg/kg, i.p., 30 min after administration of ISO (ISO plus pilocarpine group. After the treatments all groups were observed for 1h. The antioxidant effect of ISO on the pilocarpine model was assessed by determining the activity of glutathione peroxidase (GPx, glutathione-S-transferase (GST and catalase (CAT as well as the levels of reactive species (RS and lipid peroxidation (LP. In vitro, ISO (5 μM reduced RS and LP. ISO (1.0 mg/kg and abolished seizures and death induced by pilocarpine in rats. ISO protected against the increase in the RS and LP levels, GST activity as well as the inhibition of GPx activity caused by pilocarpine. In addition, ISO increased the catalase activity in hippocampus of seized rats. In conclusion, the dta suggest that ISO can present anticonvulsant and antioxidant properties in the pilocarpine model of seizures in rats.

  9. SINERGI ISO 9001:2000 - CMMI PADA INDUSTRI PENGEMBANG PERANGKAT LUNAK

    Directory of Open Access Journals (Sweden)

    Leo Willyanto Santoso

    2005-01-01

    Full Text Available All sectors of society including softwere industry, have a big concern about quality, both of product quality and service quality. The need to manage risk, has a strong relation with quality and increases system complexity. Standarization in determining quality, ISO is a must for all software developer. If we study further, ISO 9001:2000 still has some weakness especially for implementation in software product. This paper presents a comparative analysis of quality approaches to risk management. This paper also provide a general overview of all the risks aspects treated in ISO 9001:2000 standards and CMMI model version 1.1. In this research, we obtain a strategy to implement ISO 9001:2000 and CMMI together when we make a planing to increase software process. Besides it produces analysis how to change position from ISO 9001:2000 to CMMI. In the implementation on software industry PT 'X', obtain get various benefits that has never been obtained before. Abstract in Bahasa Indonesia : Semua hal dalam hidup ini selalu memperhatikan masalah kualitas, baik itu berupa kualitas produk ataupun kualitas layanan. Pada industri perangkat lunak, hal ini tidak dibedakan, kebutuhan untuk menghasilkan produk yang berkualitas akan meningkatkan kekompleksan dari sebuah sistem. Standarisasi dalam penentuan kualitas, ISO sudah menjadi keharusan bagi para pengembang perangkat lunak. Apabila diteliti lebih lanjut, ISO 9001:2000 masih mempunyai banyak kekurangan, khususnya untuk diaplikasikan dalam produk perangkat lunak.Pada penelitian ini, akan dibahas analisis perbandingan dengan melakukan pendekatan kualitas untuk meningkatkan proses perangkat lunak dengan melakukan mapping antara ISO 9001:2000 dengan CMMI. Hal-hal yang dibahas berupa aspek-aspek dari standard ISO dan CMMI versi 1.1. Pada penelitian ini, dapat diperoleh strategi untuk menerapkan ISO 9001:2000 dan CMMI secara sinergi ketika merencanakan untuk melakukan peningkatan proses perangkat lunak. Selain itu

  10. Lessons learned with ISO 14001 at DOE sites

    Energy Technology Data Exchange (ETDEWEB)

    Wilkinson, C. H., LLNL

    1998-03-01

    ISO 14001 is the international standard for environmental management systems (EMS). The standard applies the `plan, do, check, act` management system model to assure that the environmental impacts of operations are fully considered in planning and facility operations. ISO 14001 has grown in popularity in both the public and the private sector and has seen increasing utility within the U.S. Department of Energy (DOE). While there is no final DOE policy or requirement for ISO 14001 EMS implementation, ISO 14001 commands an active presence at many DOE sites. In general, the impetus for ISO 14001 in the DOE complex has been either an initiative by site management contractors to improve performance, or an actual requirement in the new management contracts for the sites. Several DOE sites now are committed to implement EMS`s in conformance with ISO 14001: Brookhaven National Laboratory (BNL), Hanford, Idaho National Engineering and Environmental Laboratory (INEEL), Kansas City Plant, Nevada Test Site, Savannah River Site (SRS), Waste Isolation Pilot Project (WIPP), West Valley. Several other DOE sites are expected to proceed in the near future with an EMS consistent with ISO 14001. However, not all sites are proceeding with an ISO 14001 EMS based on individual site business considerations. This paper describes the status of EMS implementation at these sites and identifies lessons learned that may be of use to other DOE sites.

  11. Evaluation of ISO EN 13606 as a result of its implementation in XML.

    Science.gov (United States)

    Austin, Tony; Sun, Shanghua; Hassan, Taher; Kalra, Dipak

    2013-12-01

    The five parts of the ISO EN 13606 standard define a means by which health-care records can be exchanged between computer systems. Starting within the European standardisation process, it has now become internationally ratified in ISO. However, ISO standards do not require that a reference implementation be provided, and in order for ISO EN 13606 to deliver the expected benefits, it must be provided not as a document, but as an operational system that is not vendor specific. This article describes the evolution of an Extensible Markup Language (XML) Schema through three iterations, each of which emphasised one particular approach to delivering an executable equivalent to the printed standard. Developing these operational versions and incorporating feedback from users of these demonstrated where implementation compromises were needed and exposed defects in the standard. These are discussed herein. They may require a future technical revision to ISO EN 13606 to resolve the issues identified.

  12. Evaluation of ISO EN 13606 as a result of its implementation in XML

    Science.gov (United States)

    Sun, Shanghua; Hassan, Taher; Kalra, Dipak

    2013-01-01

    The five parts of the ISO EN 13606 standard define a means by which health-care records can be exchanged between computer systems. Starting within the European standardisation process, it has now become internationally ratified in ISO. However, ISO standards do not require that a reference implementation be provided, and in order for ISO EN 13606 to deliver the expected benefits, it must be provided not as a document, but as an operational system that is not vendor specific. This article describes the evolution of an Extensible Markup Language (XML) Schema through three iterations, each of which emphasised one particular approach to delivering an executable equivalent to the printed standard. Developing these operational versions and incorporating feedback from users of these demonstrated where implementation compromises were needed and exposed defects in the standard. These are discussed herein. They may require a future technical revision to ISO EN 13606 to resolve the issues identified. PMID:23995217

  13. OntoCR: A CEN/ISO-13606 clinical repository based on ontologies.

    Science.gov (United States)

    Lozano-Rubí, Raimundo; Muñoz Carrero, Adolfo; Serrano Balazote, Pablo; Pastor, Xavier

    2016-04-01

    To design a new semantically interoperable clinical repository, based on ontologies, conforming to CEN/ISO 13606 standard. The approach followed is to extend OntoCRF, a framework for the development of clinical repositories based on ontologies. The meta-model of OntoCRF has been extended by incorporating an OWL model integrating CEN/ISO 13606, ISO 21090 and SNOMED CT structure. This approach has demonstrated a complete evaluation cycle involving the creation of the meta-model in OWL format, the creation of a simple test application, and the communication of standardized extracts to another organization. Using a CEN/ISO 13606 based system, an indefinite number of archetypes can be merged (and reused) to build new applications. Our approach, based on the use of ontologies, maintains data storage independent of content specification. With this approach, relational technology can be used for storage, maintaining extensibility capabilities. The present work demonstrates that it is possible to build a native CEN/ISO 13606 repository for the storage of clinical data. We have demonstrated semantic interoperability of clinical information using CEN/ISO 13606 extracts. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  15. Photon iso-effective dose for cancer treatment with mixed field radiation based on dose-response assessment from human and an animal model: clinical application to boron neutron capture therapy for head and neck cancer

    Science.gov (United States)

    González, S. J.; Pozzi, E. C. C.; Monti Hughes, A.; Provenzano, L.; Koivunoro, H.; Carando, D. G.; Thorp, S. I.; Casal, M. R.; Bortolussi, S.; Trivillin, V. A.; Garabalino, M. A.; Curotto, P.; Heber, E. M.; Santa Cruz, G. A.; Kankaanranta, L.; Joensuu, H.; Schwint, A. E.

    2017-10-01

    Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson’s correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r  >  0.87 and p-values  >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed

  16. Photon iso-effective dose for cancer treatment with mixed field radiation based on dose-response assessment from human and an animal model: clinical application to boron neutron capture therapy for head and neck cancer.

    Science.gov (United States)

    González, S J; Pozzi, E C C; Monti Hughes, A; Provenzano, L; Koivunoro, H; Carando, D G; Thorp, S I; Casal, M R; Bortolussi, S; Trivillin, V A; Garabalino, M A; Curotto, P; Heber, E M; Santa Cruz, G A; Kankaanranta, L; Joensuu, H; Schwint, A E

    2017-10-03

    Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson's correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r  >  0.87 and p-values  >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed

  17. Metrological management evaluation based on ISO10012: an empirical study in ISO-14001-certified Spanish companies

    International Nuclear Information System (INIS)

    Beltran, Jaime; Rivas, Miguel; Munuzuri, Jesus; Gonzalez, Cristina

    2010-01-01

    Environmental management systems based on the ISO 14001 standard rely strongly on metrological measurement and confirmation processes to certify the extent to which organizations monitor and improve their environmental behavior. Nevertheless, the literature lacks in studies that assess the influence of these metrological processes on the performance of environmental management in organizations, even now that the international standard ISO 10012 is already available to establish requisites and guidelines for the development of a metrological management system that is compatible with any other standardized management system. This work seeks to assess that influence through the development of an evaluation model for metrological management, which is then validated through an experimental analysis of the results obtained from the application of an audit process in 11 Spanish companies, all ISO-14001-certified and operating in different industrial sectors. (author)

  18. Ecodesign Maturity Model as a framework to support the transition towards ISO 14.001: 2015 certification

    DEFF Research Database (Denmark)

    Pigosso, Daniela Cristina Antelmi; McAloone, Tim C.

    2015-01-01

    Currently, the certification standard for Environmental Management Systems (EMS) ISO 14.001:2011 is under a major revision process, regarding its structure and requirements. The current draft entails major changes related to the integration of the product life cycle perspective into business...... processes, such as product development and value chain. The standard is expected to be launched in late 2015 with a 3-year transition period. This paper explores the application of the Ecodesign Maturity Model (EcoM2) as a framework to support the planning and implementation of ISO 14.001:2015, based...

  19. [ISO 9001-2000 certification for refractive laser treatment].

    Science.gov (United States)

    Lebuisson, D A; Arson, B; Abenhaïm, A; Albou-Ganem, C; Assouline, M; Chong Sit, D; Danan, A; Montefiore, G; Montin, J-F; Nguyen-Khoa, J-L; Pietrini, D; Saragoussi, J-J; Trong, Th; Amar, R

    2005-05-01

    To obtain ISO 9001-2000 certification for laser corneal refractive treatment, never before sought in Europe. The consulting firm Veritas led the certification process with the clinic's staff manager. This ISO norm is dedicated to the implementation of a quality management system. We assessed and optimized all necessary resources, evaluating customer satisfaction using patient and referring-physician surveys. We started quality rounds including surgeons, nurses, and technicians. Based on this preparation, we redefined and explained all processes including staff responsibilities and necessary resources in the quality manual. The procedure lasted 14 months with substantial involvement on the part of the management. Unconditional ISO 9001-2000 certification was granted by the independent audit firm, BVQI, in december 2003 for refractive laser treatment. The 2000 version of the new ISO 9001-2000 seeks to meet the demand for improving health care delivery in this field, most particularly by establishing a clear procedural orientation. Such certification enhances team work, stabilizes methodologies, and reinforces cohesion and self-audit. Patients notice that the center follows a consistent quality policy and are assured that the clinic respects rules and regulations. Certification is an advantageous alternative when accreditation cannot be considered. Our article discusses the steps taken in upper management, quality management, procedural guidance, as well as customer and staff counselling. It also discusses the project's cost/benefit ratio for the organization.

  20. Accreditation - ISO/IEC 17025

    Science.gov (United States)

    Kaus, Rüdiger

    This chapter gives the background on the accreditation of testing and calibration laboratories according to ISO/IEC 17025 and sets out the requirements of this international standard. ISO 15189 describes similar requirements especially tailored for medical laboratories. Because of these similarities ISO 15189 is not separately mentioned throughout this lecture.

  1. Risk Management Model from the Perspective of the Implementing ISO 9001:2015 Standard Within Financial Services Companies

    Directory of Open Access Journals (Sweden)

    Cătălina Sitnikov

    2017-11-01

    Full Text Available In its new form, the ISO 9001:2015 standard activates and utilizes a thought pattern based on risk assessment functioning in parallel with the implementation of the system regarding quality management. Therefore, we strive to identify the risks and opportunities associated with the processes and products needed to create and implement a system of quality management based on the ISO 9001:2015 standard. This standard is defined by a strong client-based orientation, motivation and managerial involvement from the higher levels, as well as a process-based approach and a commitment towards constant improvement. By implementing the requirements of the new version of the ISO 9001:2015 standard, the organisation needs to determine all the processes necessary to the system of quality management, as well as to identify those which include activities dealing with risks and opportunities. Considering the importance and the impact of the requirements of the new version of the ISO 9001:2015 standard, starting from theoretical concepts and underscoring a set of research vectors, a model of financial risk assessment has been devised. The model is based on the correlation which can be established between the multiplicity of components relating to the components of the new standard structure, SL Annex, elements of an approach derived from risk patterns of processes and risk types which are assessed from the perspective of financial services companies.

  2. Internal Audit Status For ISO 9001 And ISO/ IEC 17025 In Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Fazila Said; Nurul Huda Mudri; Nik Arlina Ali

    2012-01-01

    The development of MS ISO 9001 and MS ISO/ IEC 17025 in Malaysian Nuclear Agency is the basic step to enhance and improve the Quality Management System (QMS) for processes and laboratories that involve customers and suppliers in delivering products and services. The effectiveness of QMS is monitored by Research and Innovation Management Centre (RIMC) to ensure that all activities related to audit such as Internal Audit are well organized and implemented as documented in quality manual and procedure. This paper will discuss the status of internal audit for processes that implement MS ISO 9001 and laboratories that accredited with MS/ ISO IEC 17025 in year 2008, 2009 and 2010. The total of non-conformance (nc) and opportunity for improvement (ofi) for processes and laboratories and their numbers as per clause in MS ISO 9001 and MS ISO/ IEC 17025 are the indicators that reflects the effectiveness of QMS. Then, the total effectiveness of QMS for MS 9001 and MS ISO/ IEC 17025 is also determined via the number of conformance clause versus non-conformance clause for those three years. (author)

  3. Plasma 8-iso-Prostaglandin F2α, a possible prognostic marker in aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Pan, De-Sheng; Yan, Min; Hassan, Muhammad; Fang, Ze-Bin; Chen, Man-Tao

    2017-06-01

    8-iso-Prostaglandin F2α (8-iso-PGF2α) is a potential biomarker of oxidative stress. This study clarified whether plasma 8-iso-PGF2α concentrations were affected and its underlying relevance to prognosis in aneurysmal subarachnoid hemorrhage (aSAH). In this prospective, observational study, a total of 170 controls and 170 aSAH patients were enrolled. Plasma 8-iso-PGF2α concentrations were detected using an ELISA. Severity was assessed by World Federation of Neurological Surgeons (WFNS) scale and modified Fisher grading scale. Clinical outcomes included 6-month mortality and poor outcome referred to as Glasgow outcome scale score of 1-3. As compared to controls, admission plasma 8-iso-PGF2α concentrations were significantly enhanced. Increased concentrations of plasma 8-iso-PGF2α correlated with WFNS scores and modified Fisher scores. 8-iso-PGF2α in plasma was an independent predictor for clinical outcomes. Under ROC curve, the predictive values of 8-iso-PGF2α concentrations resembled those of WFNS scores and modified Fisher scores for clinical outcomes. An elevation in plasma 8-iso-PGF2α concentrations is associated with the severity and poor outcome after aSAH, substantializing 8-iso-PGF2α as a potential prognostic biomarker of aSAH. Copyright © 2017. Published by Elsevier B.V.

  4. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  5. Evaluation of the homogeneity of reference flat sources used in calibration of surface contamination monitors

    International Nuclear Information System (INIS)

    Silva Junior, I.A.; Xavier, M.; Siqueira, P.T.D.; Potiens, M.P.A.

    2014-01-01

    The aim of this study was to re-evaluate the uniformity of the wide area reference sources of the Calibration Laboratory of Instruments (LCI-IPEN) used in the calibration of surface contamination monitors, according the recommendations of the ISO 8769 standard and the NRPB. In this work used six wide area reference sources of 150 cm 2 of 241 Am, 14 C, 36 Cl, 137 Cs, 90 Sr+ 90 Y and 99 Tc with reference dates between 1996 and 1997 and three sources of 100 cm 2 of 14 C, 137 Cs and 60 Co were used with reference dates 2007. Measurements were performed with a radiation monitor of the Thermo, model FH40GX with a pancake probe, model FHZ732GM. We also made several models on paper with the objective of define each measurement position and an aluminum plate with a square hole (6.25 cm 2 ) in its center, allowing the passage of the radiation only through the hole. Each wide area reference source was positioned in setup and measurements were performed in order to cover the entire surface of the source. The values of the uniformity obtained partially confirm previous data obtained in another study conducted by LCI-IPEN, showing that some wide area reference sources 150 cm 2 in disagree with ISO 8769. In the former work, just the source of 241 Am (7.3%) was within the range specified by the standard, now have sources of 241 Am (5.7%), 137 Cs (8.8%), 90 Sr+ 9 '0Y (8, 8%) and 99 Tc (9.2%) with values within the specified uniformity. The sources of 14 C (53.3%) and 36 Cl (16.6%) were outside the specified. The wide area reference sources of 100 cm 2 , show disagreement in values of uniformity of the sources 14 C (46.7%) and 60 Co (10.4%). The values of the uniformity of the wide area reference sources show that some fonts can not be used in calibrations, because not in accordance with the value of uniformity specified in ISO 8769:2010, this is a conditions to believe a laboratory according to ISO 17025, show the laboratory performs its services with a high quality. The

  6. ISO 9000

    International Nuclear Information System (INIS)

    Graham, J.F.

    1992-01-01

    The European Community has adopted the Single European Act. The act states that in order to do business in Europe after 1992, a supplied is expected to be ISO 9000 registered. This paper reports on ISO 9000, which is a systematic approach to implementing a quality system. It is not in the category of technical or product standards, but a standard relating to management of quality in that sector of a company seeking registration. If a company is already systematically practicing quality improvement, these efforts will be applicable to the ISO 9000 certification process. A company will need to refine and update procedures and develop a quality manual. An internal auditing and a corrective action system will also have to be established. The latter addresses audit results, customer complaints, quality system problems, and internal quality improvement suggestions

  7. Application of ISO 9001:2000 in a Nuclear Medicine Department

    International Nuclear Information System (INIS)

    Rayo, J.I.; Serrano, J.; Martin, R.; Corral, C.

    2002-01-01

    Since 1947 ISO has been developing voluntary technical standards over almost all sectors of business, industry, and technology. The ISO 9000 standards were published in 1987, and new versions of the standards saw daylight in 1994 and 2000. The highlights of ISO 9001:2000 are: quality management system, management responsibility, resource management, product realization and measurement, analysis and improvement. Aim: Application of ISO 9001:2000 to a Nuclear Medicine Department for provides the organization with a model to follow, customer focus, people will understand the goals of the organization and are motivated to work for objectives and lower costs and shorter cycle times through effective use of resources. Conclusion: ISO 9001:2000 focuses on continual improvement of business processes that should be a permanent objective of the Nuclear Medicine Department

  8. Boiling Patterns of Iso-asymmetric Nuclear Matter

    International Nuclear Information System (INIS)

    Tõke, Jan

    2013-01-01

    Limits of thermodynamic metastability of self-bound neutron-rich nuclear matter are explored within the framework of microcanonical thermodynamics of interacting Fermi Gas model in Thomas-Fermi approximation. It is found that as the excitation energy per nucleon of the system is increased beyond a certain limiting value, the system loses metastability and becomes unstable with respect to joint fluctuations in excitation energy per nucleon and in isospin per nucleon. As a result, part of the system is forced to boil off in a form of iso-rich non-equilibrated vapors. Left behind in such a process, identifiable with distillation, is a more iso-symmetric metastable residue at a temperature characteristic of its residual isospin content. With a progressing increase in the initial excitation energy per nucleon, more neutron-rich matter is boiled off and a more iso-symmetric residue is left behind with progressively increasing characteristic temperature. Eventually, when all excess neutrons are shed, the system boils uniformly with a further supply of excitation energy, leaving behind a smaller and smaller residue at a characteristic boiling-point temperature of iso-symmetric matter.

  9. Tinjauan Kritis Terhadap Implementasi Iso 9000

    OpenAIRE

    Purnama, Nursya’bani

    2005-01-01

    ISO 9000 telah diterima secara luas sebagai acuan sistem manajemen kualitas dan penjaminan kualitas. Perusahaan-Perusahaan yang memperoleh sertifikasi ISO dari tahun ke ke tahun mengalami pertumbu¬han yang pesat. Dengan implementasi dan memperoleh sertifikasi ISO 9000, banyak Perusahaan di dunia mem¬peroleh peningkatan kinerja. Meskipun demikian, implementasi ISO 9000 juga dihadapkan pada sejumlah ham¬batan. Implementasi ISO 9000 seringkali dikaitkan dengan Total Quality Management (TQM). Ban...

  10. Iso-α-acids, Bitter Components of Beer, Prevent Inflammation and Cognitive Decline Induced in a Mouse Model of Alzheimer's Disease*

    Science.gov (United States)

    Ano, Yasuhisa; Dohata, Atsushi; Taniguchi, Yoshimasa; Hoshi, Ayaka; Uchida, Kazuyuki; Takashima, Akihiko; Nakayama, Hiroyuki

    2017-01-01

    Alongside the rapid growth in aging populations worldwide, prevention and therapy for age-related memory decline and dementia are in great demand to maintain a long, healthy life. Here we found that iso-α-acids, hop-derived bitter compounds in beer, enhance microglial phagocytosis and suppress inflammation via activation of the peroxisome proliferator-activated receptor γ. In normal mice, oral administration of iso-α-acids led to a significant increase both in CD11b and CD206 double-positive anti-inflammatory type microglia (p iso-α-acids resulted in a 21% reduction in amyloid β in the cerebral cortex as observed by immunohistochemical analysis, a significant reduction in inflammatory cytokines such as IL-1β and chemokines including macrophage inflammatory protein-1α in the cerebral cortex (p iso-α-acid-fed mice were due to the induction of microglia to an anti-inflammatory phenotype. The present study is the first to report that amyloid β deposition and inflammation are suppressed in a mouse model of Alzheimer's disease by a single component, iso-α-acids, via the regulation of microglial activation. The suppression of neuroinflammation and improvement in cognitive function suggests that iso-α-acids contained in beer may be useful for the prevention of dementia. PMID:28087694

  11. The stability of iso-α-acids and reduced iso-α-acids in stored blood specimens.

    Science.gov (United States)

    Rodda, Luke N; Gerostamoulos, Dimitri; Drummer, Olaf H

    2014-06-01

    The long-term stability of the iso-α-acids, and three structurally similar but chemically altered iso-α-acids (known as 'reduced iso-α-acids' and consisting of the rho-, tetrahydro- and hexahydro-iso-α-acid groups) were investigated in whole blood. Pools of blank blood spiked with the four beer-specific ingredient congener groups at two different concentration levels were stored at 20°C, 4°C and -20°C; and extracted in duplicate in weeks 1, 3, 5 and 8, using a previously published method. A loss of 15% of the initial concentration was considered to indicate possible instability and losses greater than 30% demonstrated significant losses. The individual analytes within the four iso-α-acid groups were also measured to determine which iso-α-acids were subject to greater degradation and were responsible for the overall group instability. All four iso-α-acid groups showed significant losses after 8 weeks of storage under room temperature conditions in particularly the natural iso-α-acid group where major losses were observed (96% and 85% losses for low and high concentrations, respectively). Some degradation in all iso-α-acid groups were seen at 4°C samples predominantly due to the 'n' analogs of the groups showing an increased instability in blood. The -20°C storage conditions resulted in minimal changes in concentrations of all analytes. Higher than frozen storage temperatures can result in substantial changes on the stability of the iso-α-acid type groups in blood. The aim of this study was to highlight the stabilities of the IAA analytes in order to assist in the interpretation of IAA in stored blood specimens. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. On the current status of an ISO working document on the calibration and type testing of radiation protection dosemeters for photons

    International Nuclear Information System (INIS)

    Kramer, H.M.; Boehm, J.; Iles, W.J.; Thompson, I.M.G.

    1994-01-01

    In October 1992, Working Group 2 'Reference Radiations' of ISO TC85/SC2 'Nuclear Energy/Radiation Protection' officially prepared a first draft of a document with the working title: 'The Calibration of Individual and Area Dosimeters for Photon Radiation and the Determination of their Response as a Function of Photon Energy and Angle of Incidence'. On the basis of existing ISO Standards 4037 'X and γ Reference Radiations ...' and ISO 8963 'Dosimetry of X and γ Reference Radiations ...' and the recent updating of these standards, a first draft of the new working document has been prepared. An overview of its contents is presented, an account of some of the topics as yet open is given and some new data pertinent to this future standard are included. (Author)

  13. ISO 50001 and SEP Faster and Cheaper - Exploring the Enterprise-Wide Approach

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jingjing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Therkelsen, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sheaffer, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Scheihing, Paul [USDOE, Washington, DC (United States); Tamm, Yannick [Energetics, Inc. (United States)

    2017-06-01

    ISO 50001 and other management systems (e.g., ISO 9001 and ISO 14001) allow for implementation and certification at the enterprise level. The "Central Office" concept, which allows a small group of employees to manage and facilitate the organization’s energy management system (EnMS) at the enterprise level, was introduced within the ISO 50003 standard to provide guidance to ISO 50001 certification bodies. Four industrial companies have partnered with the United States Department of Energy to pilot the enterprise-wide ISO 50001/SEP concept under the Better Buildings Superior Energy Performance (SEP) Enterprise-wide Accelerator. Each organization developed a Central Office to host their EnMS while implementing ISO 50001/SEP at multiple physically separated sites. The four corporate partners tailored their Central Office implementation model to meet their own specific circumstances and needs. This paper reviews the commonalities, differences, and benefits of each of these enterprise-wide implementation models, including organizational structures, Central Office staff responsibilities, and key strategies. The cost savings and benefits of using the enterprise-wide approach were assessed, including the cost per site compared with that of a conventional, single-site ISO 50001/SEP implementation approach. This paper also discusses the drivers for the cost reductions realized through these enterprise-wide approaches. The four partner companies worked with 30 total sites. On average, these 30 sites improved energy performance by 5% annually over their SEP achievement periods, saved more than $600,000 annually in energy costs and reduced implementation cost for ISO 50001 and SEP by $19,000 and 0.8 Full Time Equivalent × years (FTE-yr) of staff time per site. The results can inform other organizations seeking to implement enterprise-wide ISO 50001/SEP, as well as energy efficiency organizations seeking to promote wider adoption of ISO 50001 implementation.

  14. ISO-66, a novel inhibitor of macrophage migration, shows efficacy in melanoma and colon cancer models.

    Science.gov (United States)

    Ioannou, Kyriaki; Cheng, Kai Fan; Crichlow, Gregg V; Birmpilis, Anastasios I; Lolis, Elias J; Tsitsilonis, Ourania E; Al-Abed, Yousef

    2014-10-01

    Macrophage migration inhibitory factor (MIF) is a pleiotropic pro-inflammatory cytokine, which possesses a contributing role in cancer progression and metastasis and, thus, is now considered a promising anticancer drug target. Many MIF-inactivating strategies have proven successful in delaying cancer growth. Here, we report on the synthesis of ISO-66, a novel, highly stable, small-molecule MIF inhibitor, an analog of ISO-1 with improved characteristics. The MIF:ISO-66 co-crystal structure demonstrated that ISO-66 ligates the tautomerase active site of MIF, which has previously been shown to play an important role in its biological functions. In vitro, ISO-66 enhanced specific and non-specific anticancer immune responses, whereas prolonged administration of ISO-66 in mice with established syngeneic melanoma or colon cancer was non-toxic and resulted in a significant decrease in tumor burden. Subsequent ex vivo analysis of mouse splenocytes revealed that the observed decrease in tumor growth rates was likely mediated by the selective in vivo expansion of antitumor-reactive effector cells induced by ISO-66. Compared to other MIF-inactivating strategies employed in vivo, the anticancer activity of ISO-66 is demonstrated to be of equal or better efficacy. Our findings suggest that targeting MIF, via highly specific and stable compounds, such as ISO-66, may be effective for cancer treatment and stimulation of anticancer immune responses.

  15. ISO 14000 : environmental management systems

    International Nuclear Information System (INIS)

    Boutin, C.; Emard, C.; Lalonde, G.; Levesque, A.; Robitaille, R.; Rollin, A.L.; Thibeault, I.

    1996-01-01

    This book is addressed to the managers, professionals, and government agents which wish to know the philosophy of the step as well as the stages to be followed for the establishment of a system of environmental management in conformity with the standards of the series ISO 14000. This work locates ISO 14000 in the historical context of its development by describing the bonds with other standards in place of which those of the series ISO 9000. This book answers questions that arise regarding a companies step toward accreditation to ISO 14000

  16. NDT technical assessment for ISO 17025 and ISO 17020 certification

    International Nuclear Information System (INIS)

    Mohamad Pauzi Ismail

    2011-01-01

    ISO 17025 is an international standard that states the requirement criteria for testing and calibration laboratory, while ISO 17020 is for inspection body. Standard Malaysia is the accreditation body for both standards. The author involved in the technical assessment for both standards both in Nuclear Malaysia and outside. The experience in performing NDT assessment activity is explained and discussed. The comparison between both standards is also discussed. (author)

  17. Explanation and practice on ISO 9000

    International Nuclear Information System (INIS)

    Kwon, Dong Myeong

    2001-01-01

    This book reveals introduction on revision of ISO 9000:2000 with full account and contents of revision and change method change into ISO 9001:2000, the basic principle on ISO 9000:2000 and improvement and aim, definition on explanation, method for detail term, demand for ISO/KS A 9001:2000, quality management system development and transition way, standardization for quality management, manual of quality and making procedure and guide, case of quality manual and procedure and guide and ISO 9001:2000 / KS A 9001:2001 an English-Korean translation.

  18. Laadun- ja riskienhallinta johtamisjärjestelmässä ISO 9001:2015 ja ISO 31000:2009 mukaisesti

    OpenAIRE

    Reinvall, Niko; Karhunen, Joonas

    2015-01-01

    Tämän opinnäytetyön tarkoituksena on tarkastella riskienhallinnan ja laadunhallintajärjestelmien suhdetta ISO 9001:2015 ja ISO 31000:2009-standardien viitekehyksessä, tutkimuskysymyksen ollessa ”miten ja miksi integroida ISO 9001 mukaista laadunhallintaa ja ISO 31000 mukaista riskienhallintaa organisaation johtamisjärjestelmään”. Lisäksi työssä tarkastellaan standardien välisiä yhtymäkohtia ja riskienhallinnan merkitystä ISO 9001:2015 mukaisessa laadunhallintajärjestelmässä. Työn tilaaja...

  19. IMPLEMENTASI QUALITY MANAGEMENT SYSTEM ISO 9001:2008 DALAM PEMBELAJARAN PRODUKTIF KEAHLIAN TEKNIK MESIN DAN OTOMOTIF SMK

    Directory of Open Access Journals (Sweden)

    Mochammad Ariful Ulfi

    2013-07-01

    Full Text Available The implementation of ISO 9001:2008 quality management system in the productive learning on the mechanical engineering and automotive in vocational high school. This research uses qualitative approach in term of a case study. The research is conducted at SMKN I Purwosari. The results of this research show that (1 the reason of the ISO imple­mentation is to obtain community trust, to improve compe­titiveness, and to increase the quality of the graduates; (2 the implementation of the quality management system in the learning process refers to the concept of PDCA of the ISO system; (3 the obstacles occured during the implementation of ISO is due to the lack of teachers’ awareness on the ISO system; and (4 some efforts to overcome those obstacles include developing commitment among all elements, socialization, supervision, and doing some preventive efforts. Penelitian ini menggunakan pendekatan kualitatif dengan rancangan studi kasus. Penelitian dilaksanakan di SMK Negeri 1 Purwosari. Adapun fokus penelitian adalah alasan penerapan ISO, implementasi dalam pembelajaran, hambatan, dan upaya mengatasi hambatan pelaksanaan ISO 9001:2008. Hasil penelitian menunjukkan   (1 alasan penerapan ISO adalah agar sekolah dipercaya masyarakat, meningkatkan daya saing, dan mening­kat­kan mutu lulusan; (2 implementasi dalam pembelajaran mengacu  pada konsep PDCA ke dalam sistem manajemen mutu ISO; (3 hambat­an implementasi ISO adalah tingkat kesadaran guru terhadap ISO yang rendah; (4 upaya mengatasi hambatan adalah membangun komitmen bersama, sosiali­sasi, supervisi, dan melakukan usaha pencegahan.

  20. 75 FR 7581 - RTO/ISO Performance Metrics; Notice Requesting Comments on RTO/ISO Performance Metrics

    Science.gov (United States)

    2010-02-22

    ... performance communicate about the benefits of RTOs and, where appropriate, (2) changes that need to be made to... of staff from all the jurisdictional ISOs/RTOs to develop a set of performance metrics that the ISOs/RTOs will use to report annually to the Commission. Commission staff and representatives from the ISOs...

  1. Iso-α-acids, Bitter Components of Beer, Prevent Inflammation and Cognitive Decline Induced in a Mouse Model of Alzheimer's Disease.

    Science.gov (United States)

    Ano, Yasuhisa; Dohata, Atsushi; Taniguchi, Yoshimasa; Hoshi, Ayaka; Uchida, Kazuyuki; Takashima, Akihiko; Nakayama, Hiroyuki

    2017-03-03

    Alongside the rapid growth in aging populations worldwide, prevention and therapy for age-related memory decline and dementia are in great demand to maintain a long, healthy life. Here we found that iso-α-acids, hop-derived bitter compounds in beer, enhance microglial phagocytosis and suppress inflammation via activation of the peroxisome proliferator-activated receptor γ. In normal mice, oral administration of iso-α-acids led to a significant increase both in CD11b and CD206 double-positive anti-inflammatory type microglia ( p iso-α-acids resulted in a 21% reduction in amyloid β in the cerebral cortex as observed by immunohistochemical analysis, a significant reduction in inflammatory cytokines such as IL-1β and chemokines including macrophage inflammatory protein-1α in the cerebral cortex ( p iso-α-acid-fed mice were due to the induction of microglia to an anti-inflammatory phenotype. The present study is the first to report that amyloid β deposition and inflammation are suppressed in a mouse model of Alzheimer's disease by a single component, iso-α-acids, via the regulation of microglial activation. The suppression of neuroinflammation and improvement in cognitive function suggests that iso-α-acids contained in beer may be useful for the prevention of dementia. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  2. Quality Assurance in Engineering Education: Comparison of Accreditation Schemes and ISO 9001.

    Science.gov (United States)

    Karapetrovic, Stanislav; Rajamani, Divakar; Willborn, Walter

    1998-01-01

    Outlines quality assurance schemes for distance-education technologies that are based on the ISO 9000 family of international quality-assurance standards. Argues that engineering faculties can establish such systems on the basis of and integrated with accreditation schemes. Contains 34 references. (DDR)

  3. The impact of ISO/TS 16949 on automotive industries and created organizational capabilities from its implementation

    Directory of Open Access Journals (Sweden)

    Bakhtiar Ostadi

    2010-12-01

    Full Text Available ISO/TS 16949 is an ISO Technical Specification. ISO/TS 16949 achieves the objectives which are continually to improve the production of automobile parts and related services, and to strengthen the international competition for the automotive industry and its suppliers. By applying this quality system standard, automotive manufacturers could offer superior products and good services to customers. The more the companies know about the benefits if quality management systems such as ISO/TS 16949, better they can seek interest and determine indices of these systems. So, this standard has been implemented in companies considering a number of benefits. In this paper, we carry out an empirical study in order to verify the importance these benefits and ranking them based on the value of importance. Finally, the study tends to provide a reference guide considering benefits assessment and created organizational capabilities from this standard for the automotive industry in pursuing ISO/TS 16949 and procuring maximum benefit from the results.

  4. DETAILED CHEMICAL KINETIC MODELING OF ISO-OCTANE SI-HCCI TRANSITION

    Energy Technology Data Exchange (ETDEWEB)

    Havstad, M A; Aceves, S M; McNenly, M J; Piggott, W T; Edwards, K D; Wagner, R M; Daw, C S; Finney, C A

    2009-10-12

    The authors describe a CHEMKIN-based multi-zone model that simulates the expected combustion variations in a single-cylinder engine fueled with iso-octane as the engine transitions from spark-ignited (ST) combustion to homogeneous charge compression ignition (HCCI) combustion. The model includes a 63-species reaction mechanism and mass and energy balances for the cylinder and the exhaust flow. For this study they assumed that the SI-to-HCCI transition is implemented by means of increasing the internal exhaust gas recirculation (EGR) at constant engine speed. This transition scneario is consistent with that implemented in previously reported experimental measurements on an experimental engine equipped with variable valve actuation. They find that the model captures many of the important experimental trends, including stable SI combustion at low EGR ({approx} 0.10), a transition to highly unstable combustion at intermediate EGR, and finally stable HCCI combustion at very high EGR ({approx} 0.75). Remaining differences between the predicted and experimental instability patterns indicate that there is further room for model improvement.

  5. Security Process Capability Model Based on ISO/IEC 15504 Conformant Enterprise SPICE

    Directory of Open Access Journals (Sweden)

    Mitasiunas Antanas

    2014-07-01

    Full Text Available In the context of modern information systems, security has become one of the most critical quality attributes. The purpose of this paper is to address the problem of quality of information security. An approach to solve this problem is based on the main assumption that security is a process oriented activity. According to this approach, product quality can be achieved by means of process quality - process capability. Introduced in the paper, SPICE conformant information security process capability model is based on process capability modeling elaborated by world-wide software engineering community during the last 25 years, namely ISO/IEC 15504 that defines the capability dimension and the requirements for process definition and domain independent integrated model for enterprise-wide assessment and Enterprise SPICE improvement

  6. Analysis of Advantages and Disadvantages of Current Operational Risk Management Models (AS/NZS 4360, AS/NZS ISO 9000, AS/NZS ISO 14000, AS/NZS 4801, AS/NZS 3806, AS/NZS 4444

    Directory of Open Access Journals (Sweden)

    Ferry Jie

    2002-09-01

    Full Text Available This paper will describe about the analysis of advantages and disadvantages of current operational risk management models (AS/NZS 4360: Risk Management, AS/NZS 4801: Occupational Health and Safety Management Systems, AS/NZS ISO 9001: Quality Management System, AS/NZS ISO 14001: Environment Management System, AS/NZS 3806: Compliance Management System, AS/NZS 4444: Information Security Management  based on expert experiences and extracting the literature review. The advantages of most current models are widely adopted by industries of various of sizes as the basis for their operational risk management. In addition, they may help the organizations to improve the operations and competitiveness. However, there are some disadvantages of most current models such as the models are very general (guidance only, not specific to cover particular risks of industries.  And they don’t have the specific tools and processes.  In addition, they may not be able to integrate all elements of the management systems such as safety, health, environment, quality, security, and compliance. 

  7. Inter ISO Market Coordination by Calculating Border Locational Marginal Prices

    Directory of Open Access Journals (Sweden)

    BABIC, A. B.

    2013-05-01

    Full Text Available In this paper the methodology for solving Locational Marginal Price (LMP differences (inconsistency of LMPs that arise at the boundary buses between separate power markets is proposed. The algorithm developed enables us to obtain consistent LMP values at the boundary buses between interconnected ISOs. A Primal-Dual Interior Point based optimal power flow (OPF is applied, with complete set of power system physical limit constraints, to solve a regional spot market. The OPF is implemented such that producer and consumer behaviors are modeled simultaneously, while the welfare is maximized. In this paper a generalized methodology for multiple ISOs case is proposed and later it is practically applied on two interconnected independent entities. The algorithm for approximation of cost coefficients of generators and dispatchable loads for neighboring ISOs is proposed. The developed algorithm enables participating ISOs to obtain LMPs at the boundary buses with other interconnected ISOs. By controlling interchange of electric power at the scheduled level, regional spot markets are resolved eliminating possible exercise of market power by individual interconnected ISOs. Results of proposed methodology are tested on the IEEE 118-bus power system.

  8. Model-based Development of Safety-critical Functions and ISO 26262 Work Products using modified EAST-ADL

    Directory of Open Access Journals (Sweden)

    Bülent Sari

    2017-07-01

    Full Text Available Safety is becoming more and more important with the ever increasing level of safety related E/E Systems built into the cars. Increasing functionality of vehicle systems through electrification of power train, in future even more by autonomous driving, leads to complexity in designing system, software and safety architecture. ISO 26262 aims to reduce the complexity and to approve the traceability of the different safety activities. This paper presents an approach about model-based development of system, software and safety architecture using Electronics Architecture and Software Technology – Architecture Description Language (EAST-ADL, being in line with the relevant standard ISO 26262. In particular, we briefly discuss how the main safety related activities, such as hazard analysis and risk assessment, developing functional and technical safety concepts and performing safety analysis can be performed model-based and how the activities can be related with system and software development. The state-of-art is also provided and compared with the proposed approach.

  9. ISO 639-1 and ISO 639-2: International Standards for Language Codes. ISO 15924: International Standard for Names of Scripts.

    Science.gov (United States)

    Byrum, John D.

    This paper describes two international standards for the representation of the names of languages. The first (ISO 639-1), published in 1988, provides two-letter codes for 136 languages and was produced primarily to meet terminological needs. The second (ISO 639-2) appeared in late 1998 and includes three-letter codes for 460 languages. This list…

  10. Lean environmental management integration system for sustainability of ISO 14001:2004 standard implementation

    Directory of Open Access Journals (Sweden)

    Perumal Puvanasvaran

    2014-10-01

    Full Text Available Purpose: The purpose of this study is to present a model for integrating Lean Principles with ISO 14001 Environmental Management System.Design/methodology/approach: To achieve the objective of the study, the methodology used in this study is based on preliminary literature review of ISO 14001 standards and Lean Principles as well as certain case reports from various proponents and authors of ISO 14001 and Lean as noted in various articles and journals and some books.Findings and Originality/value: The findings of this study are a new model called Lean Environmental Management Integration System (LEMIS has been developed and leads to the creation of these measurement standards for evaluating the organization, making its environmental efforts more realistic, focused and attainable.Research limitations/implications: Future research should be conducted case studies in this direction are required to be conducted for examining the feasibility of amalgamation and implementing ISO 14001:2004 standards with the philosophy of Lean Principles to enable the achievement of world class standards.Practical implications: This model helps to eliminate any wasteful processes in the organization’s implementation of the ISO 14001 standard thus leading to higher environmental performance.  Integrating the standard with Lean principles through LEMIS model helps to specify these performance measures making the standard achieve sustainability and continual improvement.Originality/value: This study presents a unique approach of integrating the two main models, namely Lean Principles and ISO 14001 Environmental Management System, as a single framework benefiting contemporary organizations.

  11. Reference radiation fields - Simulated workplace neutron fields - Part 2: Calibration fundamentals related to the basic quantities

    International Nuclear Information System (INIS)

    2008-01-01

    ISO 8529-1, ISO 8529-2 and ISO 8529-3, deal with the production, characterization and use of neutron fields for the calibration of personal dosimeters and area survey meters. These International Standards describe reference radiations with neutron energy spectra that are well defined and well suited for use in the calibration laboratory. However, the neutron spectra commonly encountered in routine radiation protection situations are, in many cases, quite different from those produced by the sources specified in the International Standards. Since personal neutron dosimeters, and to a lesser extent survey meters, are generally quite energy dependent in their dose equivalent response, it might not be possible to achieve an appropriate calibration for a device that is used in a workplace where the neutron energy spectrum and angular distribution differ significantly from those of the reference radiation used for calibration. ISO 8529-1 describes four radionuclide based neutron reference radiations in detail. This part of ISO 12789 includes the specification of neutron reference radiations that were developed to closely resemble radiation that is encountered in practice

  12. Photovoltaic Calibrations at the National Renewable Energy Laboratory and Uncertainty Analysis Following the ISO 17025 Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Keith [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    The measurement of photovoltaic (PV) performance with respect to reference conditions requires measuring current versus voltage for a given tabular reference spectrum, junction temperature, and total irradiance. This report presents the procedures implemented by the PV Cell and Module Performance Characterization Group at the National Renewable Energy Laboratory (NREL) to achieve the lowest practical uncertainty. A rigorous uncertainty analysis of these procedures is presented, which follows the International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement. This uncertainty analysis is required for the team’s laboratory accreditation under ISO standard 17025, “General Requirements for the Competence of Testing and Calibration Laboratories.” The report also discusses additional areas where the uncertainty can be reduced.

  13. Ignition studies of n-heptane/iso-octane/toluene blends

    KAUST Repository

    Javed, Tamour

    2016-07-09

    Ignition delay times of four ternary blends of n-heptane/iso-octane/toluene, referred to as Toluene Primary Reference Fuels (TPRFs), have been measured in a high-pressure shock tube and in a rapid compression machine. The TPRFs were formulated to match the research octane number (RON) and motor octane number (MON) of two high-octane gasolines and two prospective low-octane naphtha fuels. The experiments were carried out over a wide range of temperatures (650–1250 K), at pressures of 10, 20 and 40 bar, and at equivalence ratios of 0.5 and 1.0. It was observed that the ignition delay times of these TPRFs exhibit negligible octane dependence at high temperatures (T > 1000 K), weak octane dependence at low temperatures (T < 700 K), and strong octane dependence in the negative temperature coefficient (NTC) regime. A detailed chemical kinetic model was used to simulate and interpret the measured data. It was shown that the kinetic model requires general improvements to better predict low-temperature conditions and particularly requires improvements for high sensitivity (high toluene concentration) TPRF blends. These datasets will serve as important benchmark for future gasoline surrogate mechanism development and validation. © 2016 The Combustion Institute

  14. The ISO 50001 Impact Estimator Tool (IET 50001 V1.1.4) - User Guide and Introduction to the ISO 50001 Impacts Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Therkelsen, Peter L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Aghajanzadeh, Arian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McKane, Aimee T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-01

    ISO 50001-Energy management systems – Requirements with guidance for use, is an internationally developed standard that provides organizations with a flexible framework for implementing an energy management system (EnMS) with the goal of continual energy performance improvement. The ISO 50001 standard was first published in 2011 and has since seen growth in the number of certificates issued around the world, primarily in the industrial (agriculture, manufacturing, and mining) and service (commercial) sectors. Policy makers in many regions and countries are looking to or are already using ISO 50001 as a basis for energy efficiency, carbon reduction, and other energy performance improvement schemes. The Impact Estimator Tool 50001 (IET 50001 Tool) is a computational model developed to assist researchers and policy makers determine the potential impact of ISO 50001 implementation in the industrial and service (commercial) sectors for a given region or country. The IET 50001 Tool is based upon a methodology initially developed by the Lawrence Berkeley National Laboratory that has been improved upon and vetted by a group of international researchers. By using a commonly accepted and transparent methodology, users of the IET 50001 Tool can easily and clearly communicate the potential impact of ISO 50001 for a region or country.

  15. Control: the effects of ISO

    NARCIS (Netherlands)

    Laura Ilzarbe; PhD Everard van Kemenade; Maria-Jezus Alvarez

    2007-01-01

    De effecten van ISO-certificering zoals gerapporteerd in wetenschappelijk onderzoek. Met speciale aandacht voor de resultaten in het onderwijs. ISO 9000:2000 doet het nadrukkelijk beter dan haar vorige versies.

  16. Reference neutron radiations. Part 1: Characteristics and methods of production

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 1. of ISO 8529 specifies the reference neutron radiations, in the energy range from thermal up to 20 MeV, for calibrating neutron-measuring devices used for radiation protection purposes and for determining their response as a function of neutron energy. Reference radiations are given for neutron fluence rates of up to 1x10 9 m 2 s-1 , corresponding, at a neutron energy of 1 MeV, to dose-equivalent rates of up to 100 mSv h -1 . This part of ISO 8529 is concerned only with the methods of producing and characterizing the neutron reference radiations. The procedures for applying these radiations for calibrations are described in ISO 8529-2 and ISO 8529-3. The reference radiations specified are the following: neutrons from radionuclide sources, including neutrons from sources in a moderator; neutrons produced by nuclear reactions with charged particles from accelerators; neutrons from reactors. In view of the methods of production and use of them, these reference radiations are divided, for the purposes of this part of ISO 8529, into the following two separate sections. In clause 4, radionuclide neutron sources with wide spectra are specified for the calibration of neutron measuring devices. These sources should be used by laboratories engaged in the routine calibration of neutron-measuring devices, the particular design of which has already been type tested. In clause 5, accelerator-produced monoenergetic neutrons and reactor-produced neutrons with wide or quasi monoenergetic spectra are specified for determining the response of neutron-measuring devices

  17. Handbook of camera monitor systems the automotive mirror-replacement technology based on ISO 16505

    CERN Document Server

    2016-01-01

    This handbook offers a comprehensive overview of Camera Monitor Systems (CMS), ranging from the ISO 16505-based development aspects to practical realization concepts. It offers readers a wide-ranging discussion of the science and technology of CMS as well as the human-interface factors of such systems. In addition, it serves as a single reference source with contributions from leading international CMS professionals and academic researchers. In combination with the latest version of UN Regulation No. 46, the normative framework of ISO 16505 permits CMS to replace mandatory rearview mirrors in series production vehicles. The handbook includes scientific and technical background information to further readers’ understanding of both of these regulatory and normative texts. It is a key reference in the field of automotive CMS for system designers, members of standardization and regulation committees, engineers, students and researchers.

  18. International Organization for Standardization (ISO) 15189.

    Science.gov (United States)

    Schneider, Frank; Maurer, Caroline; Friedberg, Richard C

    2017-09-01

    The College of American Pathologists (CAP) offers a suite of laboratory accreditation programs, including one specific to accreditation to the international organization for standardization (ISO) 15189 standard for quality management specific to medical laboratories. CAP leaders offer an overview of ISO 15189 including its components, internal audits, occurrence management, document control, and risk management. The authors provide a comparison of its own ISO 15189 program, CAP 15189, to the CAP Laboratory Accreditation Program. The authors conclude with why laboratories should use ISO 15189. © The Korean Society for Laboratory Medicine.

  19. Software Assurance Curriculum Project Volume 1: Master of Software Assurance Reference Curriculum

    Science.gov (United States)

    2010-08-01

    developed products. The above definition was derived from these references: [IEEE-CS 2008] ISO /IEC 12207 , IEEE Std 12207 -2008, Systems and Software...Systems [CNSS 2009]. Software quality Capability of a software product to satisfy stated and implied needs when used under specified conditions [ ISO ...Curriculum ISO International Organization for Standardization IT information technology KA knowledge area KU knowledge unit MBA Master of

  20. A practical synthesis of long-chain iso-fatty acids (iso-C12–C19 and related natural products

    Directory of Open Access Journals (Sweden)

    Mark B. Richardson

    2013-09-01

    Full Text Available A gram-scale synthesis of terminally-branched iso-fatty acids (iso-C12–C19 was developed commencing with methyl undec-10-enoate (methyl undecylenate (for iso-C12–C14 or the C15 and C16 lactones pentadecanolide (for iso-C15–C17 and hexadecanolide (for iso-C18–C19. Central to the approaches outlined is the two-step construction of the terminal isopropyl group through addition of methylmagnesium bromide to the ester/lactones and selective reduction of the resulting tertiary alcohols. Thus, the C12, C17 and C18 iso-fatty acids were obtained in three steps from commercially-available starting materials, and the remaining C13–C16 and C19 iso-fatty acids were prepared by homologation or recursive dehomologations of these fatty acids or through intercepting appropriate intermediates. Highlighting the synthetic potential of the iso-fatty acids and various intermediates prepared herein, we describe the synthesis of the natural products (S-2,15-dimethylpalmitic acid, (S-2-hydroxy-15-methylpalmitic acid, and 2-oxo-14-methylpentadecane.

  1. ISO 9000 implementation in a middle-scale Turkish organization

    OpenAIRE

    Uzkan, Ismail Burak

    1996-01-01

    Ankara : The Department of Management and Graduate School of Business Administration of Bilkent Univ., 1996. Thesis (Master's) -- Bilkent University, 1996. Includes bibliographical references leaves 62-63 In organizations of every kind, quality is regarded as a means to an end customer satisfaction in all aspects of a product or service. ISO 9000 Standards aim customer satisfaction in that respect. In this study, a real life case which analyses a middle-scale Turkish firm t...

  2. International Standardization of the Clinical Dosimetry of Beta Radiation Brachytherapy Sources: Progress of an ISO Standard

    Science.gov (United States)

    Soares, Christopher

    2006-03-01

    In 2004 a new work item proposal (NWIP) was accepted by the International Organization for Standardization (ISO) Technical Committee 85 (TC85 -- Nuclear Energy), Subcommittee 2 (Radiation Protection) for the development of a standard for the clinical dosimetry of beta radiation sources used for brachytherapy. To develop this standard, a new Working Group (WG 22 - Ionizing Radiation Dosimetry and Protocols in Medical Applications) was formed. The standard is based on the work of an ad-hoc working group initiated by the Dosimetry task group of the Deutsches Insitiut für Normung (DIN). Initially the work was geared mainly towards the needs of intravascular brachytherapy, but with the decline of this application, more focus has been placed on the challenges of accurate dosimetry for the concave eye plaques used to treat ocular melanoma. Guidance is given for dosimetry formalisms, reference data to be used, calibrations, measurement methods, modeling, uncertainty determinations, treatment planning and reporting, and clinical quality control. The document is currently undergoing review by the ISO member bodies for acceptance as a Committee Draft (CD) with publication of the final standard expected by 2007. There are opportunities for other ISO standards for medical dosimetry within the framework of WG22.

  3. [ISO 9001 conformity in research, teaching and rehabilitation].

    Science.gov (United States)

    Howorka, K; Kletschka, G; Pumprla, J; Thoma, H

    1998-01-01

    Quality assurance, in particular in the areas of development and production of medical devices, is one of the tasks of biomedical engineering. The interdisciplinary working group "Functional Rehabilitation and Group Education, Vienna" is committed to the development and implementation of group education models on three levels: (1) direct education/instruction of patients with chronic diseases, (2) university research and teaching, and (3) development of technical aids for rehabilitation and the means for disseminating group education models in rehabilitation and therapy. Major aims were, by generating conformity with ISO 9001 standards, to achieve greater transparency and process optimization with very small resources in university (teaching, research, technical aids) and extra-university (rehabilitation) areas. A secondary aim was the establishment of interdisciplinary (clinical and biomedical) cooperation at university level. In all main areas (research, teaching and group education/instruction), ISO 9001-conformity was achieved by our activities on three methodological levels: (1) description and analysis of processes, (2) use of ISO 9001 standards for evaluating internal processes, and (3) optimization measures. The following article contains relevant elements of the quality manual and quality assurance system, and offers a typical example of innovative cooperation between medicine and medical engineering.

  4. The European Large Area ISO Survey

    DEFF Research Database (Denmark)

    Oliver, S.; Rowan-Robinson, M.; Alexander, D.M.

    2000-01-01

    We describe the European Large Area ISO Survey (ELAIS). ELAIS was the largest single Open Time project conducted by ISO, mapping an area of 12 deg(2) at 15 mu m with ISOCAM and at 90 mu m with ISOPHOT. Secondary surveys in other ISO bands were undertaken by the ELAIS team within the fields of the...

  5. Using ISOS consensus test protocols for development of quantitative life test models in ageing of organic solar cells

    DEFF Research Database (Denmark)

    Kettle, J.; Stoichkov, V.; Kumar, D.

    2017-01-01

    As Organic Photovoltaic (OPV) development matures, the demand grows for rapid characterisation of degradation and application of Quantitative Accelerated Life Tests (QALT) models to predict and improve reliability. To date, most accelerated testing on OPVs has been conducted using ISOS consensus...

  6. Mednarodni standardi - veličine in enote (ISO 31-0 do 31-13): International standards - quantities and units (ISO 31-0 to 31-13):

    OpenAIRE

    Glavič, Peter

    2002-01-01

    In this paper the international standards ISO 31 (Quantities and units) are presented with the following parts: ISO 31-0 (General principles), ISO 31-1 (Space and time), ISO 31-2 (Periodic and related phenomena), ISO 31-3 (Mechanics), ISO 31-4 (Heat), ISO 31-5 (Electricity and magnetism), ISO 31-8 (Physical chemistry and molecular physics), ISO 31-12 (Characteristic numbers)and others. The emphasis is given on the basic principles, which is important for writing of reports, presentations, art...

  7. ISO27001 in a Windows Environment

    CERN Document Server

    Honan, Brian

    2010-01-01

    Ideal for project managers, IT and security staff, this book plugs the gap in current guidance literature for ISO27001. ISO27001, the information security management standard (ISMS), is providing a significant challenge for many organisations. One of the key areas of confusion is the relationship between the ISO27001 ISMS project manager and those responsible for implementing the technical controls.

  8. Certification of ISO 9001: SSDL experiences

    International Nuclear Information System (INIS)

    Noriah Mod Ali

    2005-01-01

    Efforts given to maintain the quality management based on the ISO 9000 requirement able to improved the existing system, strengthen the customer confidence and to satisfied the worker needs. It gives direct impact on the harmonization of the Radiation Protection Program in the country. SSDL experiences towards obtaining the the ISO 9002/ISO 9001 certification and its maintenance are discussed in details. (Author)

  9. From ISO 9001:2008 to ISO 9001:2015: Significant changes and their impacts to aspiring organizations

    Science.gov (United States)

    Sari, Y.; Wibisono, E.; Wahyudi, R. D.; Lio, Y.

    2017-11-01

    ISO 9001:2015 is the latest version of ISO Quality Management System standard that has been updated recently from ISO 9001:2008. It is necessary for all organizations that have implemented and been certified with ISO 9001:2008 to prepare the transition and upgrade their Quality Management System because the certification will expire by September 2018. This paper attempts to provide knowledge on the significant changes from ISO 9001:2008 to ISO 9001:2015, what new requirements are added, and how they would impact the organizations. An exploratory and applied research was chosen as the research approach and aimed to explore what transition designs are needed to anticipate the changes as well as their impacts. The research applied a methodology of Plan-Do-Check-Action (PDCA) cycle into four organizations and their results were compared and discussed to explain the transition designs. Some qualitative methods such as observation and interview were used to collect the data. By addressing the new requirements, three transition designs that should be prepared are: (i) identifying needs from interested parties, (ii) analyzing internal and external factors of the organizations to formulate relevant strategies and quality objectives, and (iii) registering risks associated to business processes as well as organizational strategies.

  10. ISO specifications and unclear energy quality certification

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Hun

    2011-12-15

    This book indicates necessity of quality management and change of company environment, basic conception of quality management and thinking way, role of each class for quality management, necessity and purpose of introduction of ISO9000 family, authentication process and construct method of ISO9000 family, authentication effect of ISO9000 family, present condition of ISO9000 family, standard of quality certification and quality management and explanation of 2001 requirement of KSA9000.

  11. ISO specifications and unclear energy quality certification

    International Nuclear Information System (INIS)

    Lee, Tae Hun

    2011-12-01

    This book indicates necessity of quality management and change of company environment, basic conception of quality management and thinking way, role of each class for quality management, necessity and purpose of introduction of ISO9000 family, authentication process and construct method of ISO9000 family, authentication effect of ISO9000 family, present condition of ISO9000 family, standard of quality certification and quality management and explanation of 2001 requirement of KSA9000.

  12. Adopting ISO 9712:2005 and ISO/IEC 17024:2003 as Philippine national standard for NDT for global competitiveness

    International Nuclear Information System (INIS)

    Banaga, Renato T.; Mateo, Alejandro J.

    2005-01-01

    This paper describes and promotes the adoption of ISO 9712: 2005 edition and the ISO/IEC 17024: 2003 edition by the Philippines to be globally competitive. ISO 9712 is a standard for qualifications and certification of nondestructive testing (NDT) personnel while ISO/IEC 17024 is conformity assessment-general requirements for bodies operating certification of persons. ISO 9712 defies that the effectiveness of an application of nondestructive testing depends on the capabilities and qualifications of personnel performing the NDT test. The Philippines through the national certifying body (NCB) implements the certification of proficiency of NDT personnel in accordance with the Philippine National Standards (PNS-146: 1998) This standard (formerly PNS-146: 1987) was originally based from the draft ISO/TC-135/SC7N35.3 and was later revised to conform to the latest ISO FDIS 9712: 1997 and rename PNS-146: 1998. Now with the issuance of the latest ISO 9712:2005 edition and to keep abreast with the current trends of NDT technology, present time and conditions dictates for us to revise our NDT personnel certification to the latest edition of ISO 9712. The International Atomic Energy Agency (IAEA) supports the establishment of a common NDT standard. The IAEA is promoting af financially supporting the establishment in developing countries of only one NDT standard. The IAEA through the Regional Cooperative Agreement (RCA) has initiated the harmonization of the NDT qualification and certification of personnel in the RCA member states. In October 2001, the IAEA sponsored the Dhaka meeting where the International Committee for Nondestructive Testing (ICNDT), Asia-Pacific Committee (APCNDT) and RCA member states representatives drafted a Mutual Recognition Agreement (MRA) for the Asia-Pacific NDT (APCNDT) personnel certification schemes acording to ISO 9712. Last August 2005, IAEA/RCA sponsored the Colombo meeting for the harmonization of regional NDT applying ISO 9712 and ISO

  13. Listen to ISO 9001:2015 for organizational competitiveness: Correlation between change management and improvement

    OpenAIRE

    Fonseca Luis Miguel; Domingues José Pedro

    2017-01-01

    In their quest to achieve superior performance and business results, organizations have extensively adopted models such as ISO 9001 Quality Managements Standards. Research supports that Quality Management System brings significant benefits for organizations competitiveness and success and more than 1 million organizations of all activity sectors worldwide have implemented ISO 9001. In a world of increasingly complexity and interconnection, the revised ISO 9001:2015 International Standard aims...

  14. Analysis of the Environmental Management System based on ISO 14001 on the American continent.

    Science.gov (United States)

    Neves, Fábio de Oliveira; Salgado, Eduardo G; Beijo, Luiz A

    2017-09-01

    The American continent is in broad economic and industrial development. Consequently, a more detailed discussion of the impacts generated by such development is needed. Moreover, there is an increase in the number of ISO 14001 certificates issued to this continent. Given the above, no studies were found that bridge the gap to identify the influence of different factors on ISO 14001 in the Americas. Thus, this article has as its main aim to check which economic, environmental and cultural factors have influence on ISO 14001 Certification in the American Continent. The data were collected in the ISO Survey, World Bank, United Nations Development Programme and International Energy Agency. Among the countries of that continent, thirteen were analyzed and only two did not show the economic factors as the influence factor in the multiple regression models fitted with Brazil and the United State. In these models, all presented environmental factors as influencing factors. Only in Brazil the index HDI presented as cultural factor in multiple regression model fitted. The economic factors: Gross Domestic Product and exports of goods and services and environmental: Carbon Dioxide (CO 2 ) and fossil fuel consumption were the most influential in ISO 14001 certification. Venezuela, Uruguay, Colombia and the United States were countries that had factors dependent on each other, featuring the environmental marketing. Briefly, this study brings up several implications: to the academy, with the proposal of new concepts and guidance on the factors that assist in ISO 14001 certification in the American Continent. Additionally, taking into account the industry, the factors serve as efficiency parameters for the implementation of ISO 14001 standard, and for the Government to improve through factors that do not fit in multiple regression models. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The assurance as a result of blood chemical analysis by ISO-GUM and QE

    Energy Technology Data Exchange (ETDEWEB)

    Iwaki, Y., E-mail: yasuo.iwaki@nifty.ne.j

    2010-07-01

    The Quality Assurance (QA) of measurand has been discussed over many years by Quality Engineering (QE). It is need to more discuss about ISO standard. It is mining to find out root fault element for improvement of measured accuracy, and it remove. The accuracy assurance needs to investigate the Reference Material (RM) for calibration and an improvement accuracy of data processing. This research follows the accuracy improvement in field of data processing by how to improve of accuracy. As for the fault element relevant to measurement accuracy, in many cases, two or more element is buried exist. The QE is to assume the generating frequency of fault state, and it is solving from higher ranks for fault factor first by 'Failure Mode and Effects Analysis' (FMEA). Then QE investigate the root cause over the fault element by 'Root Cause Analysis (RCA)' and 'Fault Tree Analysis (FTA)' and calculate order to the generating element of assume specific fault. These days comes, the accuracy assurance of measurement result became duty in the Professional Test (PT). ISO standard was legislated by ISO-GUM (Guide of express Uncertainty in Measurement) as guidance of an accuracy assurance in 1993 [1] for QA. Analysis method of ISO-GUM is changed into Exploratory Data Analysis (EDA) from Analysis of Valiance (ANOVA). EDA calculate one by one until an assurance performance is obtained according to 'Law of the propagation of uncertainty'. If the truth value was unknown, ISO-GUM is changed into reference value. A reference value set up by the EDA and it does check with a Key Comparison (KC) method. KC is comparing between null hypothesis and frequency hypothesis. It performs operation of assurance by ISO-GUM in order of standard uncertainty, the combined uncertainty of many fault elements and an expansion uncertain for assurance. An assurance value is authorized by multiplying the final expansion uncertainty [2] by K of coverage factor. K-value is

  16. Promoting Strong ISO 50001 Outcomes with Supportive National Infrastructure

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee, T.; Siciliano, Graziella; de los Reyes, Pamela

    2015-08-04

    The ISO 50001 standard is a key mechanism for reducing greenhouse gas emissions and improving energy efficiency globally. An increasing number of companies are seeking certification, creating the need for personnel that are competent to conduct ISO 50001 certification audits. The growth of ISO 50001 is expected to accelerate as more companies integrate ISO 50001 into their corporate sustainability strategies and supplier requirements. Robust implementation of ISO 50001 represents an important tool for countries with climate change mitigation goals. Because of its dual focus on continual improvement of an organization’s energy management system (EnMS) and its energy performance improvement, ISO 50001 requires skills of both implementers and certification auditors that are not well-supported by current credentials and training. This paper describes an effort to address skill gaps of certification auditors, a critical factor to ensure that ISO 50001 implementations are robust and result in continued energy performance improvement. A collaboration of governments through the Energy Management Working Group (EMWG), formerly under Global Superior Energy Performance (GSEP), has formed to build workforce capacity for ISO 50001 certification audits. The EMWG is leading the development of an internationally-relevant certification scheme for ISO 50001 Lead Auditor that meets requirements for ISO/IEC 17024 accreditation and ISO 50003 for defining ISO 50001 Lead Auditor competency. Wider availability of competent ISO 50001 Lead Auditors will ultimately increase the impact and market value of ISO 50001 certification and improve consistency of ISO 50001 certification outcomes by establishing a standardized and high level of knowledge and skills globally.

  17. Improving Earth Science Metadata: Modernizing ncISO

    Science.gov (United States)

    O'Brien, K.; Schweitzer, R.; Neufeld, D.; Burger, E. F.; Signell, R. P.; Arms, S. C.; Wilcox, K.

    2016-12-01

    ncISO is a package of tools developed at NOAA's National Center for Environmental Information (NCEI) that facilitates the generation of ISO 19115-2 metadata from NetCDF data sources. The tool currently exists in two iterations: a command line utility and a web-accessible service within the THREDDS Data Server (TDS). Several projects, including NOAA's Unified Access Framework (UAF), depend upon ncISO to generate the ISO-compliant metadata from their data holdings and use the resulting information to populate discovery tools such as NCEI's ESRI Geoportal and NOAA's data.noaa.gov CKAN system. In addition to generating ISO 19115-2 metadata, the tool calculates a rubric score based on how well the dataset follows the Attribute Conventions for Dataset Discovery (ACDD). The result of this rubric calculation, along with information about what has been included and what is missing is displayed in an HTML document generated by the ncISO software package. Recently ncISO has fallen behind in terms of supporting updates to conventions such updates to the ACDD. With the blessing of the original programmer, NOAA's UAF has been working to modernize the ncISO software base. In addition to upgrading ncISO to utilize version1.3 of the ACDD, we have been working with partners at Unidata and IOOS to unify the tool's code base. In essence, we are merging the command line capabilities into the same software that will now be used by the TDS service, allowing easier updates when conventions such as ACDD are updated in the future. In this presentation, we will discuss the work the UAF project has done to support updated conventions within ncISO, as well as describe how the updated tool is helping to improve metadata throughout the earth and ocean sciences.

  18. On the influence of dexamethason-21-iso-nicotinate on histamine blood level in horses with reference to the facultative occurrence of laminitis

    International Nuclear Information System (INIS)

    Rautschka, R.

    1987-10-01

    In some cases laminitis may result as a consequence of corticoid therapy in horses. It was the aim of this investigation to prove, if there is a connection between therapeutic doses of a corticoid (dexamethasone-21-iso-nicotinate) and the liberation of histamine into the equine plasma. 40 veterinarians reported 23 cases of laminitis after treating the horses with various corticoids. To determine histamine levels in equine plasma, a method used in human medicine (Faraj, 1984) was adapted accordingly. The principle of this method consists of enzymatic coupling of a tritium-labelled methyl group to the histamine contained in plasma. From the investigation the conclusion could be drawn, that it was not possible to induce liberation of histamine into equine plasma by therapeutic doses of dexamethasone-21-iso-nicotinate. Finally, plasma levels of three horses, suffering from chronical obstructive pulmonary disease (COPD) treated therapeutically with dexamethasone-21-iso-nicotinate, were determined. Conclusively a connection between the i.m. application of dexamethasone-21-iso-nicotinate and an inducement of histamine liberation into equine plasma could not be proven. 226 refs., 11 figs., 12 tabs. (G.Q.)

  19. Complexing properties of α-iso-saccharinate: thorium

    International Nuclear Information System (INIS)

    Allard, S.; Ekberg, C.

    2005-01-01

    Full text of publication follows: In the alkaline conditions of the intended Swedish repository for long-lived, low to intermediate level waste, SFL3-5, cellulose based items will degrade with iso-saccharinate being the dominant end-product. Iso-saccharinate is a strong complexing agent for tetravalent actinides, as well as for trivalent lanthanides, and its complexation properties are of interest for the long-term repository assessment. In the presented study, the complexation of 234 Th-α-iso-saccharinate is examined using liquid-liquid- extraction and radioanalytical techniques. An organic phase consisting of 0.1 M acetylacetone in toluene was used with a 1.0 M NaClO 4 aqueous phase kept at pH 8 in a thermostated AKUFVE unit. Since the α-iso-saccharinic system consists of three species - the carboxylic α-iso-saccharinic acid, α-iso-saccharinate and α-D-iso-saccharino-1,4-lactone - care must be taken when choosing the operational pH. Keeping the aqueous phase at pH 8 results in negligible concentrations of all but the α-iso-saccharinate form while at the same time being an excellent pH for the 234 Th-acetylacetone complexation with very limited hydrolysis effect. The α- iso-saccharinate concentration was incrementally increased, and samples of equal volumes were taken from the two phases and analyzed in a liquid scintillation detector once the radioactive equilibrium between 234 Th and 234 Pa had been reached. Two complexation constants were used to fit a distribution equation to the experimental data. (authors)

  20. Reasons to Adopt ISO 50001 Energy Management System

    Directory of Open Access Journals (Sweden)

    Frederic Marimon

    2017-09-01

    Full Text Available Purpose: The main aim of this paper is to analyze the relationships between the corporate motivations that lead organizations to establish the ISO 50001 Energy Management System (EnMS standard, and the difficulties and benefits derived from its adoption. Design/methodology/approach: Three independent exploratory factor analyses (EFA were conducted in order to identify (i sources of motivation: social requirements, ecology drivers, and competitive advantage; (ii the difficulties of an ISO 50001 adoption: operational difficulties and organizational difficulty; and (iii types of benefits: ecological benefits and operational benefits. In a second step, an exploratory path analysis, performed through Structural Equation Modeling (SEM, was used to analyze the relations among motivation, difficulties, and benefits related to the adoption of the ISO 50001 standard. Findings: Social requirements explain operational difficulties, which in turn impacts on operational benefits. Ecology drivers are directly related to ecological benefits. Organizational difficulties have an inverse relationship with operational and ecological benefits. Operational difficulties are related to operational benefits and ecological benefits. Research limitations/implications: The questionnaire was disseminated to 87 Spanish companies with ISO 50001 certification. Managers and other practitioners such as consultants, auditing companies, and official organizations in charge of developing standards might find useful implications. Originality/value: The standard was published in 2011 by the International Organization for Standardization (ISO. This paper contributes to assessment of the benefits of the standard by collecting information directly from the pioneer organizations that have adopted it, and provides clues on how to implement the standard and improve it in future.

  1. Spatial Reference in Rongga (ISO 639-3: ROR), Balinese (ISO 639-3: BAN), and Indonesia (ISO 639-3: IND)

    Science.gov (United States)

    Aryawibawa, I Nyoman

    2010-01-01

    Many scholars have proposed concepts relevant to spatial reference. Herskovits (1982) proposed that the topological concepts support, contiguity and containment are basic in English, while Levinson et al.'s (2003) examination of nine unrelated languages revealed that the concept attachment is primary. Neither of these proposals is confirmed in…

  2. The International Reference Ionosphere: Model Update 2016

    Science.gov (United States)

    Bilitza, Dieter; Altadill, David; Reinisch, Bodo; Galkin, Ivan; Shubin, Valentin; Truhlik, Vladimir

    2016-04-01

    The International Reference Ionosphere (IRI) is recognized as the official standard for the ionosphere (COSPAR, URSI, ISO) and is widely used for a multitude of different applications as evidenced by the many papers in science and engineering journals that acknowledge the use of IRI (e.g., about 11% of all Radio Science papers each year). One of the shortcomings of the model has been the dependence of the F2 peak height modeling on the propagation factor M(3000)F2. With the 2016 version of IRI, two new models will be introduced for hmF2 that were developed directly based on hmF2 measurements by ionosondes [Altadill et al., 2013] and by COSMIC radio occultation [Shubin, 2015], respectively. In addition IRI-2016 will include an improved representation of the ionosphere during the very low solar activities that were reached during the last solar minimum in 2008/2009. This presentation will review these and other improvements that are being implemented with the 2016 version of the IRI model. We will also discuss recent IRI workshops and their findings and results. One of the most exciting new projects is the development of the Real-Time IRI [Galkin et al., 2012]. We will discuss the current status and plans for the future. Altadill, D., S. Magdaleno, J.M. Torta, E. Blanch (2013), Global empirical models of the density peak height and of the equivalent scale height for quiet conditions, Advances in Space Research 52, 1756-1769, doi:10.1016/j.asr.2012.11.018. Galkin, I.A., B.W. Reinisch, X. Huang, and D. Bilitza (2012), Assimilation of GIRO Data into a Real-Time IRI, Radio Science, 47, RS0L07, doi:10.1029/2011RS004952. Shubin V.N. (2015), Global median model of the F2-layer peak height based on ionospheric radio-occultation and ground-based Digisonde observations, Advances in Space Research 56, 916-928, doi:10.1016/j.asr.2015.05.029.

  3. The relevance of the ISO26000 social responsibility issues to the Hong Kong construction industry

    Directory of Open Access Journals (Sweden)

    Lisa Robyn Barnes

    2013-09-01

    Full Text Available CorporateSocial Responsibility (CSR, the responsibility of a corporation for theimpacts of its decisions on society and the environment, originated as a termin the 1950’s (Carroll 1999. However, ISO 26000 (ISO 2010“Guidance on Social Responsibility” published in November 2010, redefines “SocialResponsibility” (“SR” broadly, by reference to SR principles, core subjectsand issues. The Hong Kong Construction Industry (“HKCI” sector is critical to Hong Kong’s economy, accounting for5.6% of the GDP and 9.2% of employment in 1999 (Tang 2001. In 2011, the gross value of constructionwork by main contractors amounted to HK$128.53 billion and contributed HK$65.4 billion (HKGov 2013to the total GDP of HK$1,823.2 billion (3.6% (HKTDC 2013.The aim of this research is toinvestigate which ISO 26000 CSR issues are relevantto HKCI firms. Theprinciple findings are that: the reported level of HKCI CSR activity relativeto the 7 core subject of ISO 26000 is a function of company size; many SME’sconsider that many of the ISO 26000 SR issues are irrelevant to them; but forthe large construction contractors, reputation, legislation and or regulation andcorporate culture are drivers of improvements in CSR in the HKCI.

  4. ISO standards on the evaluation of contamination

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tamberg, T.A.

    1993-01-01

    The International Organization for Standardization (ISO) develops radiation calibration standards through Subcommittee 2 (titled ''Radiation Protection'') of Technical Committee 85 (ISO/TC85/SC2). The subcommittee has also developed standards providing guidance on the performance of measurements. ISO/TC85/SC2 consists of international technical experts who represent their countries through the international consensus process in providing guidance in several radiation protection areas. The purpose of this paper is to summarize ISO's is guidance provided in the area of contamination measurements

  5. Handbook of quality management according to the regulation DIN EN ISO/IEC 17025 for the national EU reference laboratory or air quality at the Federal Office for Environmental Protection. State of the art: September 2009; Qualitaetsmanagement-Handbuch nach DIN EN ISO/IEC 17025 fuer das Nationale EU-Referenzlabor fuer Luftqualitaet im Umweltbundesamt. Stand September 2009

    Energy Technology Data Exchange (ETDEWEB)

    Medem, Anneliese (comp.)

    2010-01-15

    The past quality management manual of the national EU reference laboratory for air quality completely was revised. The new quality management manual under consideration contains a determination of the following aspects: Organisation of construction processing, fundamental regulations of the management system concerning to quality, statements to the quality politics, paramount goals. The presented quality management system is regarded to all elements of the regulation DIN EN ISO/IEC 17025:2005 with consideration of the special requirements of the national European Union reference laboratory for air quality in the Federal Office for Environment Protection (Dessau-Rosslau, Federal Republic of Germany).

  6. Vocational High School Effectiveness Standard ISO 9001: 2008 for Achievement Content Standards, Standard Process and Competency Standards Graduates

    Directory of Open Access Journals (Sweden)

    Yeni Ratih Pratiwi

    2014-06-01

    Full Text Available Efektivitas Sekolah Menengah Kejuruan Berstandar ISO 9001:2008 terhadap Pencapaian Standar Isi, Standar Proses dan Standar Kompetensi Lulusan Abstract: The purpose of this study was to determine differences in the effectiveness of the achievement of the content standards, process standards, and competency standards in vocational already standard ISO 9001: 2008 with CMS that has not been standardized ISO 9001: 2008 both in public schools and private schools. Data collection using the questionnaire enclosed Likert scale models. Analysis of data using one-way ANOVA using SPSS. The results showed: (1 there is no difference in effectiveness between public SMK ISO standard ISO standards with private SMK (P = 0.001; (2 there are differences in the effectiveness of public SMK SMK ISO standards with ISO standards have not (P = 0.000; (3 there are differences in the effectiveness of public SMK ISO standards with private vocational yet ISO standards (P = 0.000; (4 there are differences in the effectiveness of the private vocational school with vocational standard ISO standard ISO country has not (P = 0.015; (5 there are differences in the effectiveness of the private vocational bertandar ISO with private vocational yet standardized ISO (P = 0.000; (6 there was no difference in the effectiveness of public SMK has not been standardized by the ISO standard ISO private SMK yet. Key Words: vocational high school standards ISO 9001: 2008, the standard content, process standards, competency standards Abstrak: Tujuan penelitian ini untuk mengetahui perbedaan efektivitas pencapaian standar isi, standar proses, dan standar kompetensi lulusan pada SMK yang sudah berstandar ISO 9001:2008 dengan SMK yang belum berstandar ISO 9001:2008 baik pada sekolah negeri maupun sekolah swasta. Pengumpulan data menggunakan kuisioner tertutup model skala likert. Analisis data menggunakan ANOVA one way menggunakan program SPSS. Hasil penelitian menunjukkan: (1 ada perbedaan

  7. PENGARUH CSR BERDASAR ISO 26000 TERHADAP NILAI PERUSAHAAN DENGAN KARAKTERSITIK PERUSAHAAN SEBAGAI VARIABEL MODERATING

    Directory of Open Access Journals (Sweden)

    Sri Wahjuni Latifah

    2015-01-01

    Full Text Available Research of the influence of ISO 26000 CSR toward the company’s value as a moderating variable which is done on companies listed in Indonesia Stock Exchange. The Company’s characteristics are measured by firm age, size, leverage and profitability. The data analysis was done by using double linear regression models, the first is to see the effect based on the ISO 26000 CSR and firm characteristics on value, and the second is to see the effect of interaction with the ISO 26000 corporate characteristics. The results of the study showed that there was no influence of ISO 26000, the characteristics of the company toward the value of the company. However, moderated ISO 26000 by firm characteristics affect the value of the company.

  8. Autoignition characteristics of laminar lifted jet flames of pre-vaporized iso-octane in heated coflow air

    KAUST Repository

    Al-Noman, Saeed M.; Choi, Sang Kyu; Chung, Suk-Ho

    2015-01-01

    The stabilization characteristics of laminar non-premixed jet flames of pre-vaporized iso-octane, one of the primary reference fuels for octane rating, have been studied experimentally in heated coflow air. Non-autoignited and autoignited lifted

  9. PENGEMBANGAN DAN ANALISIS KUALITAS APLIKASI PENILAIAN E-LEARNING SMK BERBASIS ISO 19796-1 DI YOGYAKARTA

    Directory of Open Access Journals (Sweden)

    Ahmad Faiq Abror

    2016-03-01

    Full Text Available Penelitian ini bertujuan untuk: (1 menghasilkan aplikasi penilaian e-learning Sekolah Menengah Kejuruan (SMK berbasis ISO 19796-1 yang dapat digunakan untuk mengevaluasi e-learning SMK di Yogyakarta menggunakan teknik Analitycal Hierarchy Process (AHP dengan metode agregasi arithmetric mean dan geometric mean, (2 menguji kualitas aplikasi dengan menggunakan strandar ISO 9126. Penelitian ini merupakan penelitian Research and Development (R&D. Proses pengembangan aplikasi menggunakan metode  Software Development Life Cycle (SDLC dengan model Waterfall. Selanjutnya pada proses pengujian kualitas aplikasi menggunakan standar ISO 9126 yang terdiri atas aspek functionality, reliability, efficiency, maintainability, usability, dan portability. Hasil penelitian menunjukkan bahwa aplikasi penilaian e-learning SMK berdasarkan ISO 19796-1 telah berhasil dikembangkan menggunakan metode Software Development Life Cycle (SDLC dengan model waterfall. Selanjutnya hasil dari analisis kualitas aplikasi menggunakan standar ISO 9126 menunjukkan bahwa aplikasi mempunyai hasil rata-rata sangat baik dan layak digunakan untuk penilaian kualitas e-learning SMK.

  10. The iso-response method: measuring neuronal stimulus integration with closed-loop experiments

    Science.gov (United States)

    Gollisch, Tim; Herz, Andreas V. M.

    2012-01-01

    Throughout the nervous system, neurons integrate high-dimensional input streams and transform them into an output of their own. This integration of incoming signals involves filtering processes and complex non-linear operations. The shapes of these filters and non-linearities determine the computational features of single neurons and their functional roles within larger networks. A detailed characterization of signal integration is thus a central ingredient to understanding information processing in neural circuits. Conventional methods for measuring single-neuron response properties, such as reverse correlation, however, are often limited by the implicit assumption that stimulus integration occurs in a linear fashion. Here, we review a conceptual and experimental alternative that is based on exploring the space of those sensory stimuli that result in the same neural output. As demonstrated by recent results in the auditory and visual system, such iso-response stimuli can be used to identify the non-linearities relevant for stimulus integration, disentangle consecutive neural processing steps, and determine their characteristics with unprecedented precision. Automated closed-loop experiments are crucial for this advance, allowing rapid search strategies for identifying iso-response stimuli during experiments. Prime targets for the method are feed-forward neural signaling chains in sensory systems, but the method has also been successfully applied to feedback systems. Depending on the specific question, “iso-response” may refer to a predefined firing rate, single-spike probability, first-spike latency, or other output measures. Examples from different studies show that substantial progress in understanding neural dynamics and coding can be achieved once rapid online data analysis and stimulus generation, adaptive sampling, and computational modeling are tightly integrated into experiments. PMID:23267315

  11. Usability evaluation of mobile applications using ISO 9241 and ISO 25062 standards.

    Science.gov (United States)

    Moumane, Karima; Idri, Ali; Abran, Alain

    2016-01-01

    This paper presents an empirical study based on a set of measures to evaluate the usability of mobile applications running on different mobile operating systems, including Android, iOS and Symbian. The aim is to evaluate empirically a framework that we have developed on the use of the Software Quality Standard ISO 9126 in mobile environments, especially the usability characteristic. To do that, 32 users had participated in the experiment and we have used ISO 25062 and ISO 9241 standards for objective measures by working with two widely used mobile applications: Google Apps and Google Maps. The QUIS 7.0 questionnaire have been used to collect measures assessing the users' level of satisfaction when using these two mobile applications. By analyzing the results we highlighted a set of mobile usability issues that are related to the hardware as well as to the software and that need to be taken into account by designers and developers in order to improve the usability of mobile applications.

  12. Co přináší třetí vydání mezinárodní normy ISO 690:2010

    OpenAIRE

    Bratková, Eva

    2010-01-01

    The review evaluates the structure and content of new, 3rd edition of the International Standard ISO 690:2010 which gives guidelines for the preparation of bibliographic references and citations to information resources. The text of new edition of the International Standard is compared with texts of the 2nd edition of the International Standard ISO 690:1987 and the 1st edition of the International Standard ISO 690-2:1997. Text of review contains some critical notes to content of published Int...

  13. [ISO 15189 medical laboratory accreditation].

    Science.gov (United States)

    Aoyagi, Tsutomu

    2004-10-01

    This International Standard, based upon ISO/IEC 17025 and ISO 9001, provides requirements for competence and quality that are particular to medical laboratories. While this International Standard is intended for use throughout the currently recognized disciplines of medical laboratory services, those working in other services and disciplines will also find it useful and appropriate. In addition, bodies engaged in the recognition of the competence of medical laboratories will be able to use this International Standard as the basis for their activities. The Japan Accreditation Board for Conformity Assessment (AB) and the Japanese Committee for Clinical Laboratory Standards (CCLS) are jointly developing the program of accreditation of medical laboratories. ISO 15189 requirements consist of two parts, one is management requirements and the other is technical requirements. The former includes the requirements of all parts of ISO 9001, moreover it includes the requirement of conformity assessment body, for example, impartiality and independence from any other party. The latter includes the requirements of laboratory competence (e.g. personnel, facility, instrument, and examination methods), moreover it requires that laboratories shall participate proficiency testing(s) and laboratories' examination results shall have traceability of measurements and implement uncertainty of measurement. Implementation of ISO 15189 will result in a significant improvement in medical laboratories management system and their technical competence. The accreditation of medical laboratory will improve medical laboratory service and be useful for patients.

  14. ENVIRONMENTAL RESPONSIBILITY MODEL BASED ON ISO 14000 MANAGEMENT SYSTEMS

    OpenAIRE

    Catalina SITNIKOV

    2012-01-01

    Worldwide corporations, as well as their stakeholders, are more conscious of the need for environmental management, SR behaviour, and sustainable growth and development. International Standards are becoming more significant for corporations to work towards common environmental management practices. ISO 14001 is the first and the broadest standard intended at a more responsible approach of corporations and the world’s most acknowledged framework for environmental management systems that assist...

  15. Intermediate species measurement during iso-butanol auto-ignition

    KAUST Repository

    Ji, Weiqi

    2015-10-01

    © 2015 The Combustion Institute.Published by Elsevier Inc. All rights reserved. This work presents the time histories of intermediate species during the auto-ignition of iso-butanol at high pressure and intermediate temperature conditions obtained using a rapid compression machine and recently developed fast sampling system. Iso-butanol ignition delays were acquired for iso-butanol/O2 mixture with an inert/O2 ratio of 7.26, equivalence ratio of 0.4, in the temperature range of 840-950 K and at pressure of 25 bar. Fast sampling and gas chromatography were used to acquire and quantify the intermediate species during the ignition delay of the same mixture at P = 25.3 bar and T = 905 K. The ignition delay times and quantitative measurements of the mole fraction time histories of methane, ethene, propene, iso-butene, iso-butyraldehyde, iso-butanol, and carbon monoxide were compared with predictions from the detailed mechanisms developed by Sarathy et al., Merchant et al., and Cai et al. It is shown that while the Sarathy mechanism well predicts the overall ignition delay time, it overpredicts ethene by a factor of 6-10, underpredicts iso-butene by a factor of 2, and overpredicts iso-butyraldehyde by a factor of 2. Reaction path and sensitivity analyses were carried out to identify the reactions responsible for the observed inadequacy. The rates of iso-butanol hydrogen atom abstraction by OH radical and the beta-scission reactions of hydroxybutyl radicals were updated based on recently published quantum calculation results. Significant improvements were achieved in predicting ignition delay at high pressures (25 and 30 bar) and the species concentrations of ethene and iso-butene. However, the updated mechanism still overpredicts iso-butyraldehyde concentrations. Also, the updated mechanism degrades the prediction in ignition delay at lower pressure (15 bar) compared to the original mechanism developed by Sarathy et al.

  16. Intermediate species measurement during iso-butanol auto-ignition

    KAUST Repository

    Ji, Weiqi; Zhang, Peng; He, Tanjin; Wang, Zhi; Tao, Ling; He, Xin; Law, Chung K.

    2015-01-01

    © 2015 The Combustion Institute.Published by Elsevier Inc. All rights reserved. This work presents the time histories of intermediate species during the auto-ignition of iso-butanol at high pressure and intermediate temperature conditions obtained using a rapid compression machine and recently developed fast sampling system. Iso-butanol ignition delays were acquired for iso-butanol/O2 mixture with an inert/O2 ratio of 7.26, equivalence ratio of 0.4, in the temperature range of 840-950 K and at pressure of 25 bar. Fast sampling and gas chromatography were used to acquire and quantify the intermediate species during the ignition delay of the same mixture at P = 25.3 bar and T = 905 K. The ignition delay times and quantitative measurements of the mole fraction time histories of methane, ethene, propene, iso-butene, iso-butyraldehyde, iso-butanol, and carbon monoxide were compared with predictions from the detailed mechanisms developed by Sarathy et al., Merchant et al., and Cai et al. It is shown that while the Sarathy mechanism well predicts the overall ignition delay time, it overpredicts ethene by a factor of 6-10, underpredicts iso-butene by a factor of 2, and overpredicts iso-butyraldehyde by a factor of 2. Reaction path and sensitivity analyses were carried out to identify the reactions responsible for the observed inadequacy. The rates of iso-butanol hydrogen atom abstraction by OH radical and the beta-scission reactions of hydroxybutyl radicals were updated based on recently published quantum calculation results. Significant improvements were achieved in predicting ignition delay at high pressures (25 and 30 bar) and the species concentrations of ethene and iso-butene. However, the updated mechanism still overpredicts iso-butyraldehyde concentrations. Also, the updated mechanism degrades the prediction in ignition delay at lower pressure (15 bar) compared to the original mechanism developed by Sarathy et al.

  17. Aplikace ISO norem v oblasti vývoje softwaru

    OpenAIRE

    Ullrich, Jan

    2007-01-01

    Thesis evaluates ISO standars used for software developement and their relationship to methodologies. It also describes processes according to international standard ISO/IEC 12207 and quality management systems according to ISO 9000. It evaluates also mothodlogy RUP and agile methodollogies. The goal of the thesis to tailor processes related to ISO 9001 to be compliant to the ISO/IEC 12207 in a small company.

  18. Transforming an EPA QA/R-2 quality management plan into an ISO 9002 quality management system.

    Science.gov (United States)

    Kell, R A; Hedin, C M; Kassakhian, G H; Reynolds, E S

    2001-01-01

    The Environmental Protection Agency's (EPA) Office of Emergency and Remedial Response (OERR) requires environmental data of known quality to support Superfund hazardous waste site projects. The Quality Assurance Technical Support (QATS) Program is operated by Shaw Environmental and Infrastructure, Inc. to provide EPA's Analytical Operations Center (AOC) with performance evaluation samples, reference materials, on-site laboratory auditing capabilities, data audits (including electronic media data audits), methods development, and other support services. The new QATS contract awarded in November 2000 required that the QATS Program become ISO 9000 certified. In a first for an EPA contractor, the QATS staff and management successfully transformed EPA's QA/R-2 type Quality Management Plan into a Quality Management System (QMS) that complies with the requirements of the internationally recognized ISO 9002 standard and achieved certification in the United States, Canada, and throughout Europe. The presentation describes how quality system elements of ISO 9002 were implemented on an already existing quality system. The psychological and organizational challenges of the culture change in QATS' day-to-day operations will be discussed for the benefit of other ISO 9000 aspirants.

  19. ISO Key Project: Exploring the Full Range of Quasar/Agn Properties

    Science.gov (United States)

    Wilkes, Belinda; Oliversen, Ronald J. (Technical Monitor)

    2003-01-01

    While most of the work on this program has been completed, as previously reported, the portion of the program dealing with the subtopic of ISO LWS data analysis and reduction for the LWS Extragalactic Science Team and its leader, Dr. Howard Smith, is still active. This program in fact continues to generate results, and newly available computer modeling has extended the value of the datasets. As a result the team requests a one-year no-cost extension to this program, through 31 December 2004. The essence of the proposal is to perform ISO spectroscopic studies, including data analysis and modeling, of star-formation regions using an ensemble of archival space-based data from the Infrared Space Observatory's Long Wavelength Spectrometer and Short Wavelength Spectrometer, but including as well some other spectroscopic databases. Four kinds of regions are considered in the studies: (1) disks around more evolved objects; (2) young, low or high mass pre-main sequence stars in star-formation regions; (3) star formation in external, bright IR galaxies; and (4) the galactic center. One prime focus of the program is the OH lines in the far infrared. The program has the following goals: 1) Refine the data analysis of ISO observations to obtain deeper and better SNR results on selected sources. The ISO data itself underwent 'pipeline 10' reductions in early 2001, and additional 'hands-on data reduction packages' were supplied by the ISO teams in 2001. The Fabry-Perot database is particularly sensitive to noise and slight calibration errors; 2) Model the atomic and molecular line shapes, in particular the OH lines, using revised Monte-Carlo techniques developed by the SWAS team at the Center for Astrophysics; 3) Attend scientific meetings and workshops; 4) Perform E&PO activities related to infrared astrophysics and/or spectroscopy.

  20. Verification of the ISO calibration method for field pyranometers under tropical sky conditions

    Science.gov (United States)

    Janjai, Serm; Tohsing, Korntip; Pattarapanitchai, Somjet; Detkhon, Pasakorn

    2017-02-01

    Field pyranomters need to be annually calibrated and the International Organization for Standardization (ISO) has defined a standard method (ISO 9847) for calibrating these pyranometers. According to this standard method for outdoor calibration, the field pyranometers have to be compared to a reference pyranometer for the period of 2 to 14 days, depending on sky conditions. In this work, the ISO 9847 standard method was verified under tropical sky conditions. To verify the standard method, calibration of field pyranometers was conducted at a tropical site located in Nakhon Pathom (13.82o N, 100.04o E), Thailand under various sky conditions. The conditions of the sky were monitored by using a sky camera. The calibration results for different time periods used for the calibration under various sky conditions were analyzed. It was found that the calibration periods given by this standard method could be reduced without significant change in the final calibration result. In addition, recommendation and discussion on the use of this standard method in the tropics were also presented.

  1. Peningkatan Mutu Proses Perguruan Tinggi Melalui Sistem Mutu Iso 9000

    Directory of Open Access Journals (Sweden)

    Th. Widia Soerjaningsih

    2004-09-01

    Full Text Available Article was made to answer these several questions;  what is acreditation and the application in the college; what is ISO 9000 quality system; why is ISO 9000 needed by the college; how ISO 9000 can support the achievement of the defined quality level; how ISO  9000 guarantee the achievement of BAN target including quality, efficiency, and relevance; what is the difference between BAN Acreditation and ISO 9000 Certification; ISO 9000 Consultant: why it is necessary, how to choose it, the line of the contract; ISO 9000 Assessor and the achieve certification: SGS and etc.; and ISO 9000 Certification Proccess Cost Aspect.   

  2. ISO science - observations of dusty discs.

    Science.gov (United States)

    Heske, A.

    1992-12-01

    ISO, the Infrared Space Observatory, will be an infrared observing facility in space. Via submission of observing proposals, use of this facility will be open to the astronomical community. The scientific payload consists of two spectrometers, a camera and a photo-polarimeter. Following an overview of the ISO mission, this paper describes the highlights of the Central Programme - proposals which are being prepared by the instrument groups, the mission scientists and the astronomers of the ISO Science Operations Team - with special emphasis on the proposals concerned with dusty discs.

  3. Sustainable development induction in organizations: a convergence analysis of ISO standards management tools' parameters.

    Science.gov (United States)

    Merlin, Fabrício Kurman; Pereira, Vera Lúciaduarte do Valle; Pacheco, Waldemar

    2012-01-01

    Organizations are part of an environment in which they are pressured to meet society's demands and acting in a sustainable way. In an attempt to meet such demands, organizations make use of various management tools, among which, ISO standards are used. Although there are evidences of contributions provided by these standards, it is questionable whether its parameters converge for a possible induction for sustainable development in organizations. This work presents a theoretical study, designed on structuralism world view, descriptive and deductive method, which aims to analyze the convergence of management tools' parameters in ISO standards. In order to support the analysis, a generic framework for possible convergence was developed, based on systems approach, linking five ISO standards (ISO 9001, ISO 14001, OHSAS 18001, ISO 31000 and ISO 26000) with sustainable development and positioning them according to organization levels (strategic, tactical and operational). The structure was designed based on Brundtland report concept. The analysis was performed exploring the generic framework for possible convergence based on Nadler and Tushman model. The results found the standards can contribute to a possible sustainable development induction in organizations, as long as they meet certain minimum conditions related to its strategic alignment.

  4. Launching the chaotic realm of iso-fractals: A short remark

    Energy Technology Data Exchange (ETDEWEB)

    O' Schmidt, Nathan [Department of Mathematics, Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Katebi, Reza [Department of Physics, California State University in Fullerton, 800 North State College Boulevard, Fullerton, CA 92831 (United States); Corda, Christian [Institute for Theoretical Physics and Advanced Mathematics Einstein-Galilei (IFM), Via Santa Gonda 14, 59100 Prato (Italy)

    2015-03-10

    In this brief note, we introduce the new, emerging sub-discipline of iso-fractals by highlighting and discussing the preliminary results of recent works. First, we note the abundance of fractal, chaotic, non-linear, and self-similar structures in nature while emphasizing the importance of studying such systems because fractal geometry is the language of chaos. Second, we outline the iso-fractal generalization of the Mandelbrot set to exemplify the newly generated Mandelbrot iso-sets. Third, we present the cutting-edge notion of dynamic iso-spaces and explain how a mathematical space can be iso-topically lifted with iso-unit functions that (continuously or discretely) change; in the discrete case examples, we mention that iteratively generated sequences like Fibonacci’s numbers and (the complex moduli of) Mandelbrot’s numbers can supply a deterministic chain of iso-units to construct an ordered series of (magnified and/or de-magnified) iso-spaces that are locally iso-morphic. Fourth, we consider the initiation of iso-fractals with Inopin’s holographic ring (IHR) topology and fractional statistics for 2D and 3D iso-spaces. In total, the reviewed iso-fractal results are a significant improvement over traditional fractals because the application of Santilli’s iso-mathematics arms us an extra degree of freedom for attacking problems in chaos. Finally, we conclude by proposing some questions and ideas for future research work.

  5. Listen to ISO 9001:2015 for organizational competitiveness: Correlation between change management and improvement

    Directory of Open Access Journals (Sweden)

    Fonseca Luis Miguel

    2017-07-01

    Full Text Available In their quest to achieve superior performance and business results, organizations have extensively adopted models such as ISO 9001 Quality Managements Standards. Research supports that Quality Management System brings significant benefits for organizations competitiveness and success and more than 1 million organizations of all activity sectors worldwide have implemented ISO 9001. In a world of increasingly complexity and interconnection, the revised ISO 9001:2015 International Standard aims to ensure that Quality Management Systems are flexible while remaining reliable. The concept of Change Management was introduced in the standard and Improvement can be achieved both in a continual/incremental mode (already present in the ISO 9001:2008 edition and in a breakthrough change/disruptive mode (new in ISO 9001:2015. ISO 9001:2015 is now closer to Business Excellence Models, such as the EFQM, that highlight the need for agility and flexibility for enduring success. To access if organizations that have already implemented ISO 9001:2015 are indeed managing change and achieving improvement, and if there is a relationship between these two variables, a survey was held with IRCA ISO 9001 Registered Auditors on a worldwide basis. Sample normality was confirmed trough Kolmogorov-Smirnov Test and the hypothesis was tested by using Pearson Correlation coefficient. The findings show that the auditee organizations have positively implemented ISO 9001:2015 requirements on change management and improvement. There is also a strong positive correlation between change management and improvement, suggesting that the organizations that properly manage change by planning, designing, implementing, and controlling change in an effective and efficient way, demonstrate a higher level of performance and results improvement. These conclusions have significant implications for the Quality/Organizational Excellence Management Body of Knowledge, requiring a new way of

  6. Analysis of reference X radiations energies adjusted for the same half-value layer

    International Nuclear Information System (INIS)

    Figueiredo, Marcus Tadeu Tanuri de; Baptista Neto, Annibal Theotonio; Silva, Teogenes Augusto da; Oliveira, Paulo Marcio Campos de

    2011-01-01

    The International Standardization Organization (ISO) defined the reference radiation for calibration and testing in x and gamma fields. The ISO 4037-1 establishes that if the first and the second half value - layers (HVL) agree within 5%, for two x- ray beams, then these two beams shall be considered the same. In this study, reference radiations with the same HVLs that were obtained trough the total filtration or the tube voltage adjustments were compared in terms of spectra and beam parameters. (author)

  7. The international ISOE programme. ISOE IAEA technical centre activities

    International Nuclear Information System (INIS)

    Gustafsson, M.

    1996-01-01

    The objective of the sub-programme on Occupational Radiation Protection in the International Atomic Energy Agency, IAEA, is to promote a harmonized approach to optimizing occupational radiation protection by developing guidelines for controlling radiation doses in the workplace and on current occupational radiation protection techniques. A significant part of this programme is the provision of assistance to developing member states to bring their radiation safety infrastructure to an appropriate level for the usage of radiation in the state. In consistence with these objectives the IAEA has been involved with the ISOE programme from its inception and has contributed actively to its growth. In 1993 an arrangement was agreed between the IAEA and the Nuclear Energy Agency, NEA, by which the IAEA co-sponsors ISOE inviting those IAEA member states which are not members of the NEA to participate cost-free in the programme. (author)

  8. ISO 14001

    DEFF Research Database (Denmark)

    Jørgensen, Tine Herreborg

    2004-01-01

    The aim of this paper is to discuss a number of issues related to ISO 14001, the international standard for environmental management systems (EMS). The standard is a process standard that leaves room for interpretation at company level as well as among lead auditors from certifying bodies...

  9. Risk in Management Systems according to ISO standard

    Directory of Open Access Journals (Sweden)

    P. Królas

    2010-07-01

    Full Text Available The purpose of this article was to present selected management standards in context of risk management. It presents main ISOmanagement standards (ISO 9001, ISO 14001, OHSAS 18001, ISO 27001, BS 25999, ISO 31000 that apply to polish enterprises. In thefirst part of this article there are analyzed management standards regarding quality, environment, occupational health and safety,information security, as well as business continuity management and risk management. The second part of the article discusses the processof dealing with risk based on chosen management standard.

  10. Comparison of Hospital standards with ISO principles and presentation appropriate model of Hospital standard development

    Directory of Open Access Journals (Sweden)

    bahram Delgoshai

    2005-02-01

    Conclusion: Writing method of evaluation items in »B hand out« has significant difference with what is done in ISO audit. Research findings showed that in spite of leaping that »B hand out« developing had in national. There are serious lacks in hospital compelete evaluaton so that consider a hospitals system, means and content beacause of lack of enough experiment in standard development based on ISO principles.

  11. Implementation and Impact of ISO 9001

    NARCIS (Netherlands)

    B. Manders (Basak)

    2015-01-01

    markdownabstract__Abstract __ The ISO 9001 quality management standard has been implemented by more than one million organizations in 187 countries since its introduction in 1987. A newer version of ISO 9001 is planned to be introduced in 2015. Even though it is widely used by organizations to

  12. Using a logical information model-driven design process in healthcare.

    Science.gov (United States)

    Cheong, Yu Chye; Bird, Linda; Tun, Nwe Ni; Brooks, Colleen

    2011-01-01

    A hybrid standards-based approach has been adopted in Singapore to develop a Logical Information Model (LIM) for healthcare information exchange. The Singapore LIM uses a combination of international standards, including ISO13606-1 (a reference model for electronic health record communication), ISO21090 (healthcare datatypes), SNOMED CT (healthcare terminology) and HL7 v2 (healthcare messaging). This logic-based design approach also incorporates mechanisms for achieving bi-directional semantic interoperability.

  13. ISO 9001 benefits and pitfalls: the path to successful certification.

    Science.gov (United States)

    Krause, M S

    1996-09-01

    The lifeblood of a business is developing and commercializing new products with minimum cost and time and maximum quality. Implementation of a quality management system is often used to achieve these goals, and the ISO 9001 standard for a business quality system is rapidly becoming the model of choice. The existence of an ISO-compliant system is a key to meeting the forthcoming regulatory requirements in the European Union and the US Food and Drug Administrations's proposed good management practices. DuPont has demonstrated leadership in the achievement of ISO registration. I describe the path to these successful registrations along with key lessons from the experience. Elements of success are management commitment, adequate resources, education, communication, total organizational involvement, and auditing of system performance. For the system to flourish and provide benefits to the users, sufficient time must be allocated for the organization to change.

  14. Iso-acoustic focusing of cells for size-insensitive acousto-mechanical phenotyping

    DEFF Research Database (Denmark)

    Augustsson, Per; Karlsen, Jonas Tobias; Su, Hao-Wei

    2016-01-01

    Mechanical phenotyping of single cells is an emerging tool for cell classification, enabling assessment of effective parameters relating to cells' interior molecular content and structure. Here, we present iso-acoustic focusing, an equilibrium method to analyze the effective acoustic impedance...... of single cells in continuous flow. While flowing through a microchannel, cells migrate sideways, influenced by an acoustic field, into streams of increasing acoustic impedance, until reaching their cell-type specific point of zero acoustic contrast. We establish an experimental procedure and provide...... theoretical justifications and models for iso-acoustic focusing. We describe a method for providing a suitable acoustic contrast gradient in a cell-friendly medium, and use acoustic forces to maintain that gradient in the presence of destabilizing forces. Applying this method we demonstrate iso-acoustic...

  15. Evaluation of the white finger risk prediction model in ISO 5349 suggests need for prospective studies.

    Science.gov (United States)

    Gemne, G; Lundström, R

    1996-05-01

    The risk prediction model for white fingers in Annex A of ISO 5349 is not likely to offer protection from all tools and all work processes. It is also probable that some work place changes it has initiated are either redundant or lack the intended effect. The main reasons for these shortcomings are the following. The often demonstrated disagreement between predicted and observed white fingers occurrence may be related to the fact that the model is based on latency data. This leads to an overestimation, to an unknown extent, of true group risks. A possible healthy worker effect, resulting in underestimation, has not been considered, and uncertainty because of recall bias is connected with using latency as effect variable in a slowly developing disorder like white fingers. The diagnostic criteria for white fingers have varied over the years, causing a possible inclusion of circulatory disturbances other than those induced by vibration. Among insufficiently clarified matters unrelated to vibration are variations in individual susceptibility and other host factors that modify vibration effects, uncertainty concerning daily or total effective exposure, and the fact that variation in work methods and processes as well as ergonomic factors other than vibration tend to make different groups incomparable form the viewpoint of risk of injury. Lack of sufficient data on vibration measurements and employment durations add to the uncertainty, as do variations in tool conditions (grinder wheels, etc) and inherent difficulties in measurement. Finally, the ISO 5349 frequency-weighting curve only relates to acute sensory effects rather than chronic effects on vascular functions like white fingers, and directional difference in sensitivity has not been incorporated in the curve. Data on exposure-response relationships are needed from prospective studies that monitor the dose of exposure to special vibration types and all relevant environmental agents, employ diagnostics with good

  16. The new international standard ISO 14001: 2004 environmental management system

    International Nuclear Information System (INIS)

    Oheba, Jamal Basher

    2006-01-01

    ISO 14001 is one standard in the ISO 14000 series of standards developed by International Organization of Standardization (ISO). Since it was published in 19096, it has rapidly become the most important environmental standard in the world. ISO 14001 is an environmental management system (EMS) that can be classified into environmental technologies provides a systematic procedure to all kind of organizations to prevent pollutions, protect environment and to improve their overall environmental performance. This new standard ISO 14001 2004 was published on November 15, 2004. It cancels and replaced the old ISO 14001-1996. Because the important of the previous standard for our local industries, firms, ...etc, this paper presents ISO 14001 concepts, issues, benefits and focuses on the stages of implementation to achieve ISO 14001-2004 certification which includes general requirements environmental policy, planning (objectives, targets ..), implementation and operations, checking and management review ...etc and presents how to apply isotop time saver software to design records, and to save time to implement ISO 14001 2004 and finally a conclusion is provided.(Author)

  17. Collaborative networks: Reference modeling

    NARCIS (Netherlands)

    Camarinha-Matos, L.M.; Afsarmanesh, H.

    2008-01-01

    Collaborative Networks: Reference Modeling works to establish a theoretical foundation for Collaborative Networks. Particular emphasis is put on modeling multiple facets of collaborative networks and establishing a comprehensive modeling framework that captures and structures diverse perspectives of

  18. Application Security in the ISO27001 Environment

    CERN Document Server

    Vinod, Vasudevan; Firosh, Ummer

    2008-01-01

    Application Security in the ISO27001 Environment demonstrates how to secure software applications within a best practice ISO/IEC 27001 environment and supports implementation of the PCI DSS Payment Application Security Standard.

  19. Can the ISO-standards on quality management be useful to libraries and how?

    DEFF Research Database (Denmark)

    Johannsen, Carl Gustav

    1994-01-01

    The aim of this paper is to discuss whether the ISO 9000 concept of quality assurance is useful in a library context or not. First, the basics of the ISO 9000 series are explained. Then, the nature of the concept is discussed and the critical views raised by quality management experts are reviewed...... concluded that the whole discussion on ISO 9000 seems a little futile because the real critical success factor for libraries aiming at Total Quality does not seem to lie in the choice of a specific quality model or guru but more is a question of commitment project on quality assurance in special libraries...

  20. Tietoturvallisuusauditointi ISO 27000-viitekehyksessä

    OpenAIRE

    Luoma, Ilmari

    2015-01-01

    Tiedon olemassaolo eri olomuodoissa muodostaa vaikeasti hallittavan uhkakentän, jonka käsittelyyn kansainvälisesti hyväksytty ISO 27000 -standardi on hyvä väline. Työn tarkoitus on perehtyä ISO/IEC 27000 -standardisarjaan, soveltaa standardin vaatimuksia laatimalla tietoturvallisuuden auditointiaineisto ja -menetelmä, sekä toteuttaa tietoturvallisuusauditointi käytännössä. Työssä esitellään tietoturvallisuuden kytkeytyminen yritysturvallisuuteen, tietoturvallisuuden osa-alueittainen ...

  1. PENGGABUNGAN PENERAPAN SISTEM JAMINAN MUTU ISO 9001:2008 DAN SISTEM HACCP KE DALAM SISTEM MANAJEMEN KEAMANAN PANGAN ISO 22000:2009 (STUDI KASUS DI PT INDOKOM SAMUDRA PERSADA [The Merger of Quality Assurance System ISO 9001:2008 and HACCP system into Food

    Directory of Open Access Journals (Sweden)

    Novri Ilmiawan

    2014-10-01

    Full Text Available The object of this research was to merge the application of HACCP system and ISO 9001:2008 in ISP company into ISO 22000:2009. The  research method used was case study method. The study was conducted on three stages. The first was the arrangement gap analysis conducted by comparing the conditions of the company with ISO 22000:2009 standards. The second was by observing sanitation and pre requisite programs. The third was by observing traceability system. The data in this research were reported descriptively, consisted of ISO 9001:2008 and HACCP application in the company and the gaps of principles in ISO 22000:2009 toward ISO 9001:2008 and HACCP. The result showed that ISP company has applied 12 steps which covered in HACCP system, and also the ISO 9001 system were appropriate with ISO 9001:2008 standards in every clauses. Pre requisite program (GMP and SSOP have been effectively applied. GMP in ISP company is categorized on the first spot (excellent. The eight keys of SSOP have been fulfilled. ISP company has been fulfilling 54 from 57 (94.74% criteria in ISO 22000:2009 standards, yet there still several things needed to be improved, which are the quality manual content  and HACCP table plan and its monitoring. The  traceability system has been applied well in ISP. Keywords : HACCP, ISO 9001, ISO 22000, GMP, SSOP.

  2. Exploring the Impact of ISO 9001, ISO 14001 and OHSAS 18001 Certification on Financial Performance: The Case of Companies listed on the Bucharest Stock Exchange

    Directory of Open Access Journals (Sweden)

    Mihaela Ionașcu

    2017-02-01

    Full Text Available The purpose of this paper is to investigate the impact of ISO 9001, ISO 14001 and OHSAS 18001 certification on the financial performance of Romanian companies listed on the Bucharest Stock Exchange (BSE. Based on audited financial statements of a population of 67 non-financial companies listed during 2013-2015 and using regression models, this paper shows, for the first time in Romania, that companies listed on BSE, implementing complex management systems (quality – environmental and/or occupational health and safety perform better, and that their performance is directly linked to the complexity of the management systems implemented.

  3. On the sound field requirements in the hearing protector standard ISO 4869-1

    DEFF Research Database (Denmark)

    Jensen, N. S.; Poulsen, Torben

    1999-01-01

    The sound field requirements in the ISO 4869 1 standard for hearing protector attenuation measurements comprise two parts: 1) a sound level difference requirement for positions around the head of the listener (ie at positions 15 cm from a reference point; up-down, front-back and left-right) and 2......) a directivity requirement for the sound incidence at the reference point, measured with a directional microphone, to ensure an approximate diffuse sound field. The level difference requirement (1) is not difficult to fulfil but the directivity requirement (2) may lead to contradicting results if the measurement...

  4. Verification the 25-kgy dose using the iso standard iso/tr 13409 for the production of bone grafts

    International Nuclear Information System (INIS)

    Otero, I.; Barrera, L.; Diaz, A.; Napoles, D.; Sanchez, E

    2001-01-01

    The purpose of this work was to verify the 25 Gy dose using the ISO standard ISO/TR 13409 for the production of bone grafts from the Tissue Bank ORTOP of the Complejo Cientifico Ortopedico Internacional Frank Pais. We performed two principal microbiological activities: bioburden estimate, pre-sterilization count plus a compensation for the efficiency of the recovery method, by ISO 11737-1 and test of sterility by ISO 11737-2. The techniques for Bioburden estimation could be direct or indirect. Choice of direct vs. indirect depends on number of contaminating micro-organisms, product configuration, ability to remove microbial contamination, effect of removal method on microbial viability, types and location of micro-organisms, nature of product and culture conditions. For a test of sterility, he product unit or SIP putted direct immersion in educated culture medium and incubate. Keep precaution to minimize level to the false positives is necessary

  5. ISO 9001 quality management systems

    CERN Document Server

    Natarajan, Dhanasekharan

    2017-01-01

    This book explains the requirements of ISO 9001 for establishing quality management system (QMS) for an organization. The requirements are illustrated with examples from industries for understanding the requirements and preparing the documents of QMS with high clarity. Methods of integrating ISO 9001 requirements with enterprise resource planning (ERP) software are presented. The software integrated approach enables process owners to focus on their core tasks of achieving the planned outputs of processes and the software generates quality records automatically.

  6. Analysis of ISO/IEC 17025 for establishment of KOLAS (Korea Laboratory Accreditation Scheme) quality assurance system

    International Nuclear Information System (INIS)

    Nam, Ji Hee

    2000-12-01

    Besides one existent accredited lab, radioactive material chemical analysis lab, five test laboratories and two calibration labs are under plan to acquire the accreditation from KOLAS. But the current Quality Manual was developed according to ISO Guide 25 that was superceded by ISO/IEC 17025. Since it is tailored to the radioactive material chemical analysis lab, a number of requirements of the Manual are not applicable to the labs other than radioactive material chemical analysis lab. Through the analysis of ISO/IEC 17025, a model of quality system was established which is not only consistent with ISO/IEC 17025 but reflective of the KAERI's situation

  7. Lean principles adoption in environmental management system (EMS - ISO 14001

    Directory of Open Access Journals (Sweden)

    Perumal Puvanasvaran

    2012-12-01

    Full Text Available Purpose: The purpose of this study is to examine the characteristic of the lean principles into ISO 14001 and to propose linkage of the lean principles and ISO 14001.Design/methodology/approach: To achieve the objective of the study, literature survey and quantitative research method using questionnaires survey are used.Findings and Originality/value: The findings of this study confirm that ISO 14001 certified company adopted lean production practices.  The study also proves that lean principles have positive and significant relationship with ISO 14001 EMS and the linkage can be made between lean principles and ISO 14001 to achieve Continual Improvement.Research limitations/implications: The small sizes of the sample of the participating companies are the main limitations of this study and this research mainly focuses on the manufacturing environment and services industry.Practical implications: This research show that all ISO 14001 companies do adopt at least one lean production practices and the main findings are lean principles has positive and highly significant relationship with ISO 14001 requirements.  This is because the integration of lean principles into ISO 14001 will serve practical methods for ISO14001 EMS to achieve the continual improvement.Originality/value: This research is amongst the first to study the combined lean principles with ISO 1400.  Based on the current situation, there is no integration within this two management system. 

  8. Standardization of Image Quality Analysis – ISO 19264

    DEFF Research Database (Denmark)

    Wüller, Dietmar; Kejser, Ulla Bøgvad

    2016-01-01

    There are a variety of image quality analysis tools available for the archiving world, which are based on different test charts and analysis algorithms. ISO has formed a working group in 2012 to harmonize these approaches and create a standard way of analyzing the image quality for archiving...... systems. This has resulted in three documents that have been or are going to be published soon. ISO 19262 defines the terms used in the area of image capture to unify the language. ISO 19263 describes the workflow issues and provides detailed information on how the measurements are done. Last...... but not least ISO 19264 describes the measurements in detail and provides aims and tolerance levels for the different aspects. This paper will present the new ISO 19264 technical specification to analyze image quality based on a single capture of a multi-pattern test chart, and discuss the reasoning behind its...

  9. Twenty new ISO standards on dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Farrar IV, H.

    2000-01-01

    Twenty standards on essentially all aspects of dosimetry for radiation processing were published as new ISO standards in December 1998. The standards are based on 20 standard practices and guides developed over the past 14 years by Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). The transformation to ISO standards using the 'fast track' process under ISO Technical Committee 85 (ISO/TC85) commenced in 1995 and resulted in some overlap of technical information between three of the new standards and the existing ISO Standard 11137 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. Although the technical information in these four standards was consistent, compromise wording in the scopes of the three new ISO standards to establish precedence for use were adopted. Two of the new ISO standards are specifically for food irradiation applications, but the majority apply to all forms of gamma, X-ray, and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruit, vegetables, meats, spices, processed foods, plastics, inks, medical wastes, and paper. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties using the new ISO Type A and Type B evaluations. Unfortunately, nine of the 20 standards just adopted by the ISO are not the most recent versions of these standards and are therefore already out of date. To help solve this problem, efforts are being made to develop procedures to coordinate the ASTM and ISO development and revision processes for these and future ASTM-originating dosimetry standards. In the meantime, an additional four dosimetry standards have recently been published by the ASTM but have

  10. A Stepwise ISO-Based TQM Implementation Approach Using ISO 9001:2015

    Directory of Open Access Journals (Sweden)

    Chen Chi-kuang

    2016-12-01

    Full Text Available The lack of an implementation roadmap always deters enterprises from choosing Total Quality Management (TQM as its major management approach. This paper proposes a stepwise ISO-based TQM implementation approach which is based on the notion of the new three-dimensional overall business excellence framework developed by Dahlgaard et al. [1]. The proposed approach consists of nine steps comprising three categories: “TQM faith building”, “TQM tools and techniques learning”, and “system development”. The steps in each of the three categories are arranged to span across the proposed nine-step approach. The ISO 9001:2015 standard is used as a case study to demonstrate the proposed approach. The ideas and benefits of the proposed approach are further discussed in relation to this illustration.

  11. New ISO standard - personnel photographic film dosemeters

    International Nuclear Information System (INIS)

    Brabec, D.

    1980-01-01

    The ISO Standard 1757 ''Personnel Photographic Film Dosemeters'', issued in June 1980, is briefly described. UVVVR's own dosemeter developed for use in the national film dosimetry service in Czechoslovakia is evaluated in relation to this ISO Standard. (author)

  12. 46 CFR 162.050-4 - Incorporation by reference: Where can I get a copy of the publications mentioned in this part?

    Science.gov (United States)

    2010-10-01

    ... ENGINEERING EQUIPMENT Pollution Prevention Equipment § 162.050-4 Incorporation by reference: Where can I get a....org): (1) International Standard ISO 8217 Third edition 2005-11-01, Petroleum products—Fuels (class F)—Specifications of marine fuels (“ISO 8217”), incorporation by reference approved for § 162.050-20. (2...

  13. PENGUKURAN KUALITAS PERANGKAT LUNAK SISTEM INFORMASI HOTEL BERBASIS STANDARD ISO 9126

    Directory of Open Access Journals (Sweden)

    Asih Sutanti

    2016-02-01

    Full Text Available Penelitian ini bertujuan bagaimana mengukur perangkat lunak yang dilihat dari sudut pandang produk, mengukur kualitas perangkat  lunak Sistem Informasi Hotel yang memerlukan  alat bantu untuk mempermudah melakukan pengukuran kualitas software tersebut berdasarkan ISO 9126 yang sesuai dengan enam karakteristik dari model kualitas software/perangkat lunak yaitu Functionability, Reliability, usability, efesiency, maintainability dan portability. Faktor kualitas umum yang paling penting diurutkan dan ditambahkan ke sub-faktor dari ISO 9126. Sehingga pihak manajemen dalam pengukurannya lebih akurat dalam memperoleh informasi untuk menentukan keputusan strategis. Melalui pemrosesan data dari masukan pengguna terhadap tingkat preferensi faktor dan sub-faktor kualitas akan diperoleh bobot faktor kualitas dan bobot relatif sub-faktor kualitas. Perkalian kedua nilai tersebut akan menghasilkan bobot absolut yang kemudian dikalikan dengan penilaian kriteria aplikasi hotel dari pengguna. Hasil akhirnya berupa nilai kualitas total dari aplikasi perangkat lunak Sistem Informasi Hotel. Setelah dilakukan pengukuran dengan enam karakteristik Standart ISO 9126, diperoleh nilai  Sistem Informasi Hotel 13.25 yang merupakan hasil pengukuran kualitas sehingga aplikasi ini tidak masuk kategori standar ISO 9126 karena ada Karakteristik Portability yait u unsur Adaptability, dan Installability tidak terpenuhi.

  14. An introduction to information security and ISO27001:2013

    CERN Document Server

    Watkins, Steve

    2013-01-01

    Up to date with the latest version of the Standard (ISO27001:2013), An Introduction to information security and ISO27001:2013 is the perfect solution for anyone wanting an accurate, fast, easy-to-read primer on information security from an acknowledged expert on ISO27001.

  15. Preface: International Reference Ionosphere - Progress in Ionospheric Modelling

    Science.gov (United States)

    Bilitza Dieter; Reinisch, Bodo

    2010-01-01

    The international reference ionosphere (lRI) is the internationally recommended empirical model for the specification of ionospheric parameters supported by the Committee on Space Research (COSPAR) and the International Union of Radio Science (URSI) and recognized by the International Standardization Organization (ISO). IRI is being continually improved by a team of international experts as new data become available and better models are being developed. This issue chronicles the latest phase of model updates as reported during two IRI-related meetings. The first was a special session during the Scientific Assembly of the Committee of Space Research (COSPAR) in Montreal, Canada in July 2008 and the second was an IRI Task Force Activity at the US Air Force Academy in Colorado Springs in May 2009. This work led to several improvements and additions of the model which will be included in the next version, IRI-201O. The issue is divided into three sections focusing on the improvements made in the topside ionosphere, the F-peak, and the lower ionosphere, respectively. This issue would not have been possible without the reviewing efforts of many individuals. Each paper was reviewed by two referees. We thankfully acknowledge the contribution to this issue made by the following reviewers: Jacob Adeniyi, David Altadill, Eduardo Araujo, Feza Arikan, Dieter Bilitza, Jilijana Cander, Bela Fejer, Tamara Gulyaeva, Manuel Hermindez-Pajares, Ivan Kutiev, John MacDougal, Leo McNamara, Bruno Nava, Olivier Obrou, Elijah Oyeyemi, Vadym Paznukhov, Bodo Reinisch, John Retterer, Phil Richards, Gary Sales, J.H. Sastri, Ludger Scherliess, Iwona Stanislavska, Stamir Stankov, Shin-Yi Su, Manlian Zhang, Y ongliang Zhang, and Irina Zakharenkova. We are grateful to Peggy Ann Shea for her final review and guidance as the editor-in-chief for special issues of Advances in Space Research. We thank the authors for their timely submission and their quick response to the reviewer comments and humbly

  16. Information security risk management for ISO27001/ISO27002

    CERN Document Server

    Calder, A; Watkins, S

    2010-01-01

    Drawing on international best practice, including ISO/IEC 27005, NIST SP800-30 and BS7799-3, the book explains in practical detail how to carry out an information security risk assessment. It covers key topics, such as risk scales, threats and vulnerabilities, selection of controls, and roles and responsibilities, and includes advice on choosing risk assessment software.

  17. Convergence Analysis of ISO/IEC 12207 and CMMI-DEV: Complementary Result from Systematic Literature Review

    Directory of Open Access Journals (Sweden)

    Javier Crisóstomo

    2017-12-01

    Full Text Available The organizations and people are demanding more and better software products and services, which implies adequate processes for its development. In the context of the software industry, there are two models, the CMMI-DEV and ISO/IEC 12207 that are influencing it. Though, they are evolving separately, recurrently they have been compared to determine its coverage (in both directions. In this study is analyzed the results of those comparisons (partials and completed to determine if the models ISO/IEC 12207 and CMMI-DEV converge at processes level. This study identified eight articles where the comparison is carried out between ISO/IEC 12207 and CMMI-DEV. The results show that technique most used is the mapping comparisons between the models and according to the analyzed studies is not possible to determine whether there is convergence in the time. However, we found some items and criterions for use in comparisons.

  18. Iso-acoustic focusing of cells for size-insensitive acousto-mechanical phenotyping.

    Science.gov (United States)

    Augustsson, Per; Karlsen, Jonas T; Su, Hao-Wei; Bruus, Henrik; Voldman, Joel

    2016-05-16

    Mechanical phenotyping of single cells is an emerging tool for cell classification, enabling assessment of effective parameters relating to cells' interior molecular content and structure. Here, we present iso-acoustic focusing, an equilibrium method to analyze the effective acoustic impedance of single cells in continuous flow. While flowing through a microchannel, cells migrate sideways, influenced by an acoustic field, into streams of increasing acoustic impedance, until reaching their cell-type specific point of zero acoustic contrast. We establish an experimental procedure and provide theoretical justifications and models for iso-acoustic focusing. We describe a method for providing a suitable acoustic contrast gradient in a cell-friendly medium, and use acoustic forces to maintain that gradient in the presence of destabilizing forces. Applying this method we demonstrate iso-acoustic focusing of cell lines and leukocytes, showing that acoustic properties provide phenotypic information independent of size.

  19. Conceptualisation for implementing total productive maintenance throught the ISO 9001:2008 standard-based quality management system

    Directory of Open Access Journals (Sweden)

    Sivaram, N. M.

    2013-08-01

    Full Text Available his paper conceptualises the integration of total productive maintenance (TPM and ISO 9001 certification by contributing a model called TPM 9001:2008. Through this conceptualisation, the eight TPM pillars are amended to the five major clauses of the ISO 9001:2008 standard. To illustrate this conceptualisation, the contents of a sub-clause of the TPM 9001:2008 model are presented, and the rationale behind its designation is appraised.

  20. ISO 9001 2000 : the quality management process

    CERN Document Server

    Tricker, Ray

    2006-01-01

    With the publication of ISO 9001:2000, there is now a single quality management ?requirements? standard that is applicable to all organisations, products and services. ISO 9001:2000 is the only standard that can be used for the certification of a QMS and its generic requirements can be used by any organisation.ISO 9001:2000 applies to all types or organisations. It is the quality standard which specifies the requirements of quality management systems for use where organisations need to demonstrate their capability to provide products and services which meet both customer needs and relevant reg

  1. [ISO 9001:2015 Certification in Quality Management].

    Science.gov (United States)

    Enders, Christian; Lang, Gabriele E; Lang, Gerhard K; Werner, Jens Ulrich

    2017-07-01

    Quality management improves the structures, processes and results of organizations of all kinds. Many practices and clinics have their existing quality management system certified according to ISO 9001, (e.g., to check their own quality management system or to obtain a testimonial against third parties). The latest version ISO 9001:2015 contains some changes, both structurally and in terms of content. These changes can be met with reasonable efforts. An ISO 9001:2015 certification represents a value for your organization, but these advantages are often not directly measurable. Georg Thieme Verlag KG Stuttgart · New York.

  2. ISO 9001 and ISO 14001: An Integrated Quality Management System for an MTR Facility SAFARI-1 Research Reactor

    International Nuclear Information System (INIS)

    Du Bruyn, J.F.; Piani, C.S.B.

    2005-01-01

    The SAFARI-1 research reactor, owned and operated by the South African Nuclear Energy Corporation (Necsa), initially obtained ISO 9001 accreditation of its Quality, Health, Safety and Environmental (QHSE) management system via international affiliation from the South African Bureau of Standards (SABS) during 1998 and re-certification according to ISO 9001 (2000) in 2003. With ever-increasing demands on nuclear facilities to demonstrate conformance to environmental policies, SAFARI-1 has now developed an Environmental Management System (EMS) that is compliant with ISO 14001 (1996) and is fully integrated with the SAFARI-1 Quality Management System (QMS). The dynamic involvement of SAFARI-1 in commercial applications demanded that any transition of the original QMS to a fully incorporated QHSE system had to be done in a way that would ensure sustained delivery of a safe and reliable service with continuous quality. At the same time, the primary vision of operating a facility under an efficient financial management programme was essential. The criteria established by the original ISO 9001 compliant QMS were appraised against the additional requirements of ISO 14001 and a suitable superstructure derived for generation and implementation of an inclusive EMS. The transitional integration of this system was planned so as to produce a QMS suitable to quality, environmental and other management related issues for application to the unique function of a nuclear research reactor. (author)

  3. Advanced Acoustic Model Technical Reference and User Manual

    Science.gov (United States)

    2010-09-01

    loss (point source). Aatm = ANSI/ ISO atmospheric absorption standard.28 Agrd = Ground reflection and attenuation losses, caused by the ground and the...433.2 1,021.8 25000 788 429.6 1,017.6 26000 754 426.1 1,013.4 27000 722 422.5 1,009.2 28000 691 418.9 1,004.9 29000 660 415.4 1,000.6 30000 631...ANSI/ ISO standard.28 Examples of the weather effects are described here. Consider a situation with winds approximately blowing from NW to SE. Figure 2

  4. Sertifikatõ ISO - mafioznaja struktura so znakom pljuss / Olesja Bõkova

    Index Scriptorium Estoniae

    Bõkova, Olesja

    2005-01-01

    Esimesed ISO sertifikaadid, mille aluseks on briti kvaliteedi standardite süsteem, anti Euroopa Liidus välja 1987. a. ISO sertifikaadid Eestis. Diagramm: Välja antud ISO 9000 sertifikaadid 1994-2004

  5. Interoperability in digital electrocardiography: harmonization of ISO/IEEE x73-PHD and SCP-ECG.

    Science.gov (United States)

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Serrano, Luis; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2010-11-01

    The ISO/IEEE 11073 (x73) family of standards is a reference frame for medical device interoperability. A draft for an ECG device specialization (ISO/IEEE 11073-10406-d02) has already been presented to the Personal Health Device (PHD) Working Group, and the Standard Communications Protocol for Computer-Assisted ElectroCardioGraphy (SCP-ECG) Standard for short-term diagnostic ECGs (EN1064:2005+A1:2007) has recently been approved as part of the x73 family (ISO 11073-91064:2009). These factors suggest the coordinated use of these two standards in foreseeable telecardiology environments, and hence the need to harmonize them. Such harmonization is the subject of this paper. Thus, a mapping of the mandatory attributes defined in the second draft of the ISO/IEEE 11073-10406-d02 and the minimum SCP-ECG fields is presented, and various other capabilities of the SCP-ECG Standard (such as the messaging part) are also analyzed from an x73-PHD point of view. As a result, this paper addresses and analyzes the implications of some inconsistencies in the coordinated use of these two standards. Finally, a proof-of-concept implementation of the draft x73-PHD ECG device specialization is presented, along with the conversion from x73-PHD to SCP-ECG. This paper, therefore, provides recommendations for future implementations of telecardiology systems that are compliant with both x73-PHD and SCP-ECG.

  6. Impact of Supplier Management Strategies on the Organizational Performance of ISO 9001 Certified Organizations

    OpenAIRE

    Fonseca, Luis Miguel; Lima, Vanda Marlene

    2015-01-01

    Purpose: The purpose of this article is to discuss the impact of Supplier orientation and the resulting Supply Chain Management (SCM) approach, on the organizational performance of ISO 9001 Quality Management Systems certified organizations. Methodology/Approach: Following a literature review, a full structural conceptual model was proposed. An online survey was administered to managers of Portuguese organizations with certified ISO 9001 Quality Management Systems. Descriptive Statistics a...

  7. Significance of ISO 9000 Quality Management System for ...

    African Journals Online (AJOL)

    Significance of ISO 9000 Quality Management System for Performance ... of ISO 9000 Quality Management System implementation for performance improvement. ... to find out the relationship between certification and process variability.

  8. Neuroprotective effects of α-iso-cubebenol on glutamate-induced neurotoxicity.

    Science.gov (United States)

    Park, Sun Young; Choi, Yung Hyun; Park, Geuntae; Choi, Young-Whan

    2015-09-01

    α-Iso-cubebenol is a natural compound isolated from Schisandra chinensis, and is reported to have beneficial bioactivity including anti-inflammatory and anti-tumor activities. Glutamate-induced oxidative neuronal damage has been implicated in a variety of neurodegenerative disorders. Here we investigated the mechanisms of α-iso-cubebenol protection of mouse hippocampus-derived neuronal cells (HT22 cells) from apoptotic cell death induced by the major excitatory neurotransmitter, glutamate. Pretreatment with α-iso-cubebenol markedly attenuated glutamate-induced loss of cell viability and release of lactate dehydrogenase), in a dose-dependent manner. α-Iso-cubebenol significantly reduced glutamate-induced intracellular reactive oxygen species and calcium accumulation. Strikingly, α-iso-cubebenol inhibited glutamate-induced mitochondrial depolarization, which releases apoptosis-inducing factor from mitochondria. α-Iso-cubebenol also suppressed glutamate-induced phosphorylation of extracellular-signal-regulated kinases. Furthermore, α-iso-cubebenol induced CREB phosphorylation and Nrf-2 nuclear accumulation and increased the promoter activity of ARE and CREB in HT22 cells. α-Iso-cubebenol also upregulated the expression of phase-II detoxifying/antioxidant enzymes such as HO-1 and NQO1. Subsequent studies revealed that the inhibitory effects of α-iso-cubebenol on glutamate-induced apoptosis were abolished by small interfering RNA-mediated knockdown of CREB and Nrf-2. These findings suggest that α-iso-cubebenol prevents excitotoxin-induced oxidative damage to neurons by inhibiting apoptotic cell death, and might be a potential preventive or therapeutic agent for neurodegenerative disorders. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. SISTEM HACCP KE DALAM SISTEM MANAJEMEN KEAMANAN PANGAN ISO 22000:2009 (STUDI KASUS DI PT INDOKOM SAMUDRA PERSADA [The Merger of Quality Assurance System ISO 9001:2008 and HACCP system into Food Safety Management SystemISO 22000:2009 (Case Study at Indoko

    Directory of Open Access Journals (Sweden)

    Novri Ilmiawan

    2014-12-01

    Full Text Available The object of this research was to merge the application of HACCP system and ISO 9001:2008 in ISP company into ISO 22000:2009. The  research method used was case study method. The study was conducted on three stages. The first was the arrangement gap analysis conducted by comparing the conditions of the company with ISO 22000:2009 standards. The second was by observing sanitation and pre requisite programs. The third was by observing traceability system. The data in this research were reported descriptively, consisted of ISO 9001:2008 and HACCP application in the company and the gaps of principles in ISO 22000:2009 toward ISO 9001:2008 and HACCP. The result showed that ISP company has applied 12 steps which covered in HACCP system, and also the ISO 9001 system were appropriate with ISO 9001:2008 standards in every clauses. Pre requisite program (GMP and SSOP have been effectively applied. GMP in ISP company is categorized on the first spot (excellent. The eight keys of SSOP have been fulfilled. ISP company has been fulfilling 54 from 57 (94.74% criteria in ISO 22000:2009 standards, yet there still several things needed to be improved, which are the quality manual content  and HACCP table plan and its monitoring. The  traceability system has been applied well in ISP .   Key words : HACCP, ISO 9001, ISO 22000, GMP, SSOP.

  10. [Accreditation of clinical laboratories based on ISO standards].

    Science.gov (United States)

    Kawai, Tadashi

    2004-11-01

    International Organization for Standardization (ISO) have published two international standards (IS) to be used for accreditation of clinical laboratories; ISO/IEC 17025:1999 and ISO 15189:2003. Any laboratory accreditation body must satisfy the requirements stated in ISO/IEC Guide 58. In order to maintain the quality of the laboratory accreditation bodies worldwide, the International Laboratory Accreditation Cooperation (ILAC) has established the mutual recognition arrangement (MRA). In Japan, the International Accreditation Japan (IAJapan) and the Japan Accreditation Board for Conformity Assessment (JAB) are the members of the ILAC/MRA group. In 2003, the Japanese Committee for Clinical Laboratory Standards (JCCLS) and the JAB have established the Development Committee of Clinical Laboratory Accreditation Program (CLAP), in order to establish the CLAP, probably starting in 2005.

  11. Environmental Management System ISO 14001

    CERN Document Server

    Haider, Syed

    2010-01-01

    This is a must-have tool for any company in the process of adopting and incorporating the ISO 14001:2004 requirements, this book and accompanying CD-ROM provides the latest updates and amendments and translates the ISO language into actionable strategy. Offering administrative solutions to managers of all sorts, it includes practical examples of policies with objectives, targets, and action plans applicable to any process related industry or an ordinary organization. With template formats and hands-on flow charts to describe step-by-step system development, documentation, and implementation ph

  12. Synthesis and Biological Activity of 2',3'-iso-Aryl-abscisic Acid Analogs.

    Science.gov (United States)

    Wan, Chuan; Wang, Mingan; Yang, Dongyan; Han, Xiaoqiang; Che, Chuanliang; Ding, Shanshan; Xiao, Yumei; Qin, Zhaohai

    2017-12-15

    2',3'- iso -Benzoabscisic acid ( iso -PhABA), an excellent selective abscisic acid (ABA) analog, was developed in our previous work. In order to find its more structure-activity information, some structural modifications were completed in this paper, including the substitution of phenyl ring and replacing the ring with heterocycles. Thus, 16 novel analogs of iso -PhABA were synthesized and screened with three bioassays, Arabidopsis and lettuce seed germination and rice seedling elongation. Some of them, i.e., 2',3'- iso -pyridoabscisic acid ( iso -PyABA) and 2',3'- iso -franoabscisic acid ( iso -FrABA), displayed good bioactivities that closed to iso -PhABA and natural (+)-ABA. Some others, for instance, substituted- iso -PhABA, exhibited certain selectivity to different physiological process when compared to iso -PhABA or (+)-ABA. These analogs not only provided new candidates of ABA-like synthetic plant growth regulators (PGRs) for practical application, but also new potential selective agonist/antagonist for probing the specific function of ABA receptors.

  13. Using ISO/IEC 12207 to analyze open source software development processes: an E-learning case study

    OpenAIRE

    Krishnamurthy, Aarthy; O'Connor, Rory

    2013-01-01

    peer-reviewed To date, there is no comprehensive study of open source software development process (OSSDP) carried out for open source (OS) e-learning systems. This paper presents the work which objectively analyzes the open source software development (OSSD) practices carried out by e-learning systems development communities and their results are represented using DEMO models. These results are compared using ISO/IEC 12207:2008. The comparison of DEMO models with ISO/IEC...

  14. [Reform of the Law DIN EN ISO 9001:2000. Commentary on the new requirements on quality management systems].

    Science.gov (United States)

    Eckert, H; Böhmer, K

    2000-09-01

    Since January this year the German translation of the third draft to the reform of the DIN EN ISO 9000 is available. The draft reveals an approximation to the models of Business Excellence. Most important changes are a far stronger customer orientation, orientation on the processes and resource management. The norms DIN EN ISO 9002 and 9003 have been removed, ISO 8402 has been integrated in the reformed DIN EN ISO 9000. Apart from that the compatibility with other management systems has been improved. It was the aim of the reform to improve the applicability for all types of business, products and services.

  15. Network interconnections: an architectural reference model

    NARCIS (Netherlands)

    Butscher, B.; Lenzini, L.; Morling, R.; Vissers, C.A.; Popescu-Zeletin, R.; van Sinderen, Marten J.; Heger, D.; Krueger, G.; Spaniol, O.; Zorn, W.

    1985-01-01

    One of the major problems in understanding the different approaches in interconnecting networks of different technologies is the lack of reference to a general model. The paper develops the rationales for a reference model of network interconnection and focuses on the architectural implications for

  16. Quality management system of a university cardiac surgery department according to DIN EN ISO 9001 : 2000.

    Science.gov (United States)

    Beholz, S; Koch, C; Konertz, W

    2003-06-01

    A quality management system (QMS) will improve quality in health care units. This report describes the introduction of a QMS according to ISO 9001:2000 in a university cardiovascular surgery department. First, a thorough analysis of all processes of patient treatment and clinical research was obtained. Multiple interfaces were defined to different departments as well as to administration units. We evaluated and optimized all necessary resources, evaluating customer satisfaction using patients' and referring physicians' surveys. We started quality rounds including surgeons, nurses and technicians. Based on this preparation, we redefined and explained all processes including their responsibilities and necessary resources in the quality manual. After a process of 18 months, an independent, accredited organization recommended that our QMS be given certification according to ISO 9001:2000. Certification of a university cardiovascular surgery department according to ISO 9001:2000 is possible, and may represent the first step towards total quality management (TQM). In complex health care units, certification of separate departments may help generate a consciousness of quality on the way to TQM.

  17. Information security in accordance with ISO/IEC 27000

    OpenAIRE

    Košćak , Damjan

    2011-01-01

    The diploma assignment discusses Information Technology Security according to standards ISO/IEC 27001 and ISO/IEC 27002. Diploma consists of two parts. In the first part of the diploma a theoretical bases of information security are presented. The second part presents the introduction of ISO/IEC 27001 security standard in the company »X« in wich I performed a practical training. In the closure my diploma work is upgraded with results of my research work and their analysis as well as wit...

  18. Effects of Cooking End-point Temperature and Muscle Part on Sensory 'Hardness' and 'Chewiness' Assessed Using Scales Presented in ISO11036:1994.

    Science.gov (United States)

    Sasaki, Keisuke; Motoyama, Michiyo; Narita, Takumi; Chikuni, Koichi

    2013-10-01

    Texture and 'tenderness' in particular, is an important sensory characteristic for consumers' satisfaction of beef. Objective and detailed sensory measurements of beef texture have been needed for the evaluation and management of beef quality. This study aimed to apply the sensory scales defined in ISO11036:1994 to evaluate the texture of beef. Longissimus and Semitendinosus muscles of three Holstein steers cooked to end-point temperatures of 60°C and 72°C were subjected to sensory analyses by a sensory panel with expertise regarding the ISO11036 scales. For the sensory analysis, standard scales of 'chewiness' (9-points) and 'hardness' (7-points) were presented to the sensory panel with reference materials defined in ISO11036. As a result, both 'chewiness' and 'hardness' assessed according to the ISO11036 scales increased by increasing the cooking end-point temperature, and were different between Longissimus and Semitendinosus muscles. The sensory results were in good agreement with instrumental texture measurements. However, both texture ratings in this study were in a narrower range than the full ISO scales. For beef texture, ISO11036 scales for 'chewiness' and 'hardness' are useful for basic studies, but some alterations are needed for practical evaluation of muscle foods.

  19. ISO sertifikaat kuulutab tootja mainet üle maailma / Ain Alvela

    Index Scriptorium Estoniae

    Alvela, Ain, 1967-

    2006-01-01

    Ilmunud ka: Delovõje Vedomosti 12. apr. lk. 24-25. ISO standardi rakendamine tagab toodangu kvaliteedi ja annab firmale usaldusväärsuse. Kommenteerib Ain Noormägi. Vt. samas: ISO 9001; ISO 14 001; Universaalne standard kohandub ettevõtte vajadustega

  20. Arranging ISO 13606 archetypes into a knowledge base.

    Science.gov (United States)

    Kopanitsa, Georgy

    2014-01-01

    To enable the efficient reuse of standard based medical data we propose to develop a higher level information model that will complement the archetype model of ISO 13606. This model will make use of the relationships that are specified in UML to connect medical archetypes into a knowledge base within a repository. UML connectors were analyzed for their ability to be applied in the implementation of a higher level model that will establish relationships between archetypes. An information model was developed using XML Schema notation. The model allows linking different archetypes of one repository into a knowledge base. Presently it supports several relationships and will be advanced in future.

  1. Weather Test Reference Year of Greenland

    DEFF Research Database (Denmark)

    Kragh, Jesper; Pedersen, Frank; Svendsen, Svend

    2005-01-01

    the construction of two test reference years of Greenland used in the work of establishing new energy frame for the coming building code of Greenland. The first test reference year is constructed using measurements of climatic parameters from the town Nuuk located in the southwestern part of Greenland. The second...... test reference year is constructed using measurements from the town Uummannaq located in the north part of Greenland on the west coast. The construction of the test reference years fulfills the procedures described in the standard EN ISO 15927-4 using the following main weather parameters: Dry bulb...... temperature, global radiation, relative humidity and mean wind speed. To construct the test reference years a program called REFYEAR was developed in MatLab. REFYEAR automatically constructs the test reference year using an input file containing the climatic measurements. The two constructed test reference...

  2. ISO developments in the United States

    International Nuclear Information System (INIS)

    Hogan, William W.

    1998-01-01

    An important feature of the restructuring process in the United States is the creation of independent system operators (ISOs) to coordinate dispatch and access to transmission grids. A number of ISOs have been proposed and are summarized here. Perhaps the greatest challenge is the pricing of transmission to give proper economic signals to market participants, and the locational pricing scheme now operating in the PJM system offers the best hope for efficient pricing. (author)

  3. A case study: forming an effective quality management system according to ISO 9000 standards

    OpenAIRE

    Zağyapan, Orhan

    1995-01-01

    Ankara : The Faculty of Management and the Graduate School of Business Administration of Bilkent Univ., 1995. Thesis (Master's) -- Bilkent University, 1995. Includes bibliographical references leaves 87-88 In today's world, companies which adopt themselves to certain internationally recognized standards are one step ahead of their competitors. ISO 9000 Quality System Standards captured the most attention among all. The aim of the standard is to provide an international bench...

  4. A Comparison Between the OSI Reference Model and the B-ISDN Protocol Reference Model

    DEFF Research Database (Denmark)

    Staalhagen, Lars

    1996-01-01

    This article aims at comparing the Open Systems Interconnection (OSI) Reference Model (RM) and the broadband integrated services digital network (B-ISDN) Protocol Reference Model (PRM). According to the International Telecommunications Union - Telecommunications Sector (ITU-T), the exact...... relationship between the lower layers of the OSI RM and the B-ISDN PRM is for further study. It is therefore the intention of this article to present some views on these relationships which hopefully could facilitate an interconnection between B-ISDN and data networks conforming to the OSI standards....

  5. Premixed flame chemistry of a gasoline primary reference fuel surrogate

    KAUST Repository

    Selim, Hatem

    2017-03-10

    Investigating the combustion chemistry of gasoline surrogate fuels promises to improve detailed reaction mechanisms used for simulating their combustion. In this work, the combustion chemistry of one of the simplest, but most frequently used gasoline surrogates – primary reference fuel 84 (PRF 84, 84 vol% iso-octane and 16 vol% n-heptane), has been examined in a stoichiometric premixed laminar flame. Time-of-flight mass spectrometry coupled with a vacuum ultraviolet (VUV) synchrotron light source for species photoionization was used. Reactants, major end-products, stable intermediates, free radicals, and isomeric species were detected and quantified. Numerical simulations were conducted using a detailed chemical kinetic model with the most recently available high temperature sub-mechanisms for iso-octane and heptane, built on the top of an updated pentane isomers model and AramcoMech 2.0 (C0C4) base chemistry. A detailed interpretation of the major differences between the mechanistic pathways of both fuel components is given. A comparison between the experimental and numerical results is depicted and rate of production and sensitivity analyses are shown for the species with considerable disagreement between the experimental and numerical findings.

  6. ISO 9001 in a neonatal intensive care unit (NICU).

    Science.gov (United States)

    Vitner, Gad; Nadir, Erez; Feldman, Michael; Yurman, Shmuel

    2011-01-01

    The aim of this paper is to present the process for approving and certifying a neonatal intensive care unit to ISO 9001 standards. The process started with the department head's decision to improve services quality before deciding to achieve ISO 9001 certification. Department processes were mapped and quality management mechanisms were developed. Process control and performance measurements were defined and implemented to monitor the daily work. A service satisfaction review was conducted to get feedback from families. In total, 28 processes and related work instructions were defined. Process yields showed service improvements. Family satisfaction improved. The paper is based on preparing only one neonatal intensive care unit to the ISO 9001 standard. The case study should act as an incentive for hospital managers aiming to improve service quality based on the ISO 9001 standard. ISO 9001 is becoming a recommended tool to improve clinical service quality.

  7. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields

    International Nuclear Information System (INIS)

    2004-01-01

    ISO 4037 consists of the following parts, under the general title X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy: Part 1: Radiation characteristics and production methods; Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV; Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence; Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields. This part 4. of ISO 4037 gives guidelines on additional aspects of the characterization of low energy photon radiations. This part of ISO 4037 also describes procedures for calibration and determination of the response of area and personal dose(rate)meters as a function of photon energy and angle of incidence. This part of ISO 4037 concentrates on the accurate determination of conversion coefficients from air kerma to Hp(10) and H*(10) for the spectra of low energy photon radiations. As an alternative to the use of conversion coefficients, the direct calibration in terms of these quantities by means of appropriate reference instruments is described

  8. Exploratory Research of ISO 14001:2015 Transition among Portuguese Organizations

    Directory of Open Access Journals (Sweden)

    Luis Miguel Fonseca

    2018-03-01

    Full Text Available The purpose of this paper is the assessment of the ISO 14001:2015 transition process among Portuguese ISO 14001 certified organizations, including those that successfully have already achieved ISO 14001:2015 certification. A considerable number of the surveyed companies proceeded with the transition to the ISO 14001:2015 by introducing slight adjustments and were supported by external consultants. Nearly all of the respondent companies (97% intend to transition until 15th September 2018. The highest ranked reported benefit is the “integrated approach with other management sub-systems” with a well-consolidated perception from the surveyed companies. This is aligned with the ISO 14001:2015 goal of improving the compatibility of management standards supported on the Annex SL. “Alignment with business strategy”, “improved top management commitment” and “improved internal and external communication” are also perceived to obtain significant benefits from ISO 14001:2015. The statistical tests carried out (Kruskal–Wallis confirmed that the perception of some achieved ISO 14001:2015 certification benefits is dependent on the size of the organization. Concerning the motivations to proceed with certification, results suggest that there is not a particular company profile that is compelled to certify their EMS based on a specific type of motivation (Internal or External. Due to ISO 14001:2015 novelty, these exploratory results should be subjected to additional research confirmation.

  9. Creating ISO/EN 13606 archetypes based on clinical information needs.

    Science.gov (United States)

    Rinner, Christoph; Kohler, Michael; Hübner-Bloder, Gudrun; Saboor, Samrend; Ammenwerth, Elske; Duftschmid, Georg

    2011-01-01

    Archetypes model individual EHR contents and build the basis of the dual-model approach used in the ISO/EN 13606 EHR architecture. We present an approach to create archetypes using an iterative development process. It includes automated generation of electronic case report forms from archetypes. We evaluated our approach by developing 128 archetypes which represent 446 clinical information items from the diabetes domain.

  10. Adaptive Control with Reference Model Modification

    Science.gov (United States)

    Stepanyan, Vahram; Krishnakumar, Kalmanje

    2012-01-01

    This paper presents a modification of the conventional model reference adaptive control (MRAC) architecture in order to improve transient performance of the input and output signals of uncertain systems. A simple modification of the reference model is proposed by feeding back the tracking error signal. It is shown that the proposed approach guarantees tracking of the given reference command and the reference control signal (one that would be designed if the system were known) not only asymptotically but also in transient. Moreover, it prevents generation of high frequency oscillations, which are unavoidable in conventional MRAC systems for large adaptation rates. The provided design guideline makes it possible to track a reference commands of any magnitude from any initial position without re-tuning. The benefits of the method are demonstrated with a simulation example

  11. PRAPI: post-transcriptional regulation analysis pipeline for Iso-Seq.

    Science.gov (United States)

    Gao, Yubang; Wang, Huiyuan; Zhang, Hangxiao; Wang, Yongsheng; Chen, Jinfeng; Gu, Lianfeng

    2018-05-01

    The single-molecule real-time (SMRT) isoform sequencing (Iso-Seq) based on Pacific Bioscience (PacBio) platform has received increasing attention for its ability to explore full-length isoforms. Thus, comprehensive tools for Iso-Seq bioinformatics analysis are extremely useful. Here, we present a one-stop solution for Iso-Seq analysis, called PRAPI to analyze alternative transcription initiation (ATI), alternative splicing (AS), alternative cleavage and polyadenylation (APA), natural antisense transcripts (NAT), and circular RNAs (circRNAs) comprehensively. PRAPI is capable of combining Iso-Seq full-length isoforms with short read data, such as RNA-Seq or polyadenylation site sequencing (PAS-seq) for differential expression analysis of NAT, AS, APA and circRNAs. Furthermore, PRAPI can annotate new genes and correct mis-annotated genes when gene annotation is available. Finally, PRAPI generates high-quality vector graphics to visualize and highlight the Iso-Seq results. The Dockerfile of PRAPI is available at http://www.bioinfor.org/tool/PRAPI. lfgu@fafu.edu.cn.

  12. Reference models supporting enterprise networks and virtual enterprises

    DEFF Research Database (Denmark)

    Tølle, Martin; Bernus, Peter

    2003-01-01

    This article analyses different types of reference models applicable to support the set up and (re)configuration of Virtual Enterprises (VEs). Reference models are models capturing concepts common to VEs aiming to convert the task of setting up of VE into a configuration task, and hence reducing...... the time needed for VE creation. The reference models are analysed through a mapping onto the Virtual Enterprise Reference Architecture (VERA) based upon GERAM and created in the IMS GLOBEMEN project....

  13. ISO's analysis of Comet Hale-Bopp

    Science.gov (United States)

    1997-03-01

    The European Space Agency's Infrared Space Observatory ISO inspected Comet Hall-Bopp during the spring and autumn of 1996. The need to keep ISO's telescope extremely cold restricts the spacecraft's pointing in relation to the Sun and the Earth and it ruled out observations at other times. The analyses of the 1996 observations are not yet complete, but already they give new insight into the nature of comets. Comet Hale-Bopp is believed to be a large comet with a nucleus up to 40 kilometres wide. It was discovered in July 1995 by two American astronomers working independently, Alan Hale and Thomas Bopp. At that time, the comet was a billion kilometres away from the Sun, but 200 times brighter than Halley's Comet was, when at a comparable distance. Comet Hale-Bopp will make its closest approach to the Earth on 22 March, and its closest approach to the Sun (perihelion) on 1 April 1997. Some scientific results from ISO The discovery of Comet Hale-Bopp occurred before ISO's launch in November 1995. When first observed by ISO in March and April 1996, the comet was still 700 million kilometres from the Sun, and almost as far from the Earth and ISO. With its privileged view of infrared wavebands inaccessible from the Earth's surface, ISO's photometer ISOPHOT discovered that carbon dioxide was an important constituent of the comet's emissions of vapour.ISOPHOT measured the temperature of the dust cloud around Comet Hale-Bopp. In March 1996, when the comet was still more than 700 million kilometres from the Sun, the dust cloud was at minus 120 degrees C. When ISOPHOT made similar observations in October 1996, the comet was 420 million kilometres from the Sun, and the dust cloud had warmed to about minus 50 degrees C. Intensive observations of Comet Hale-Bopp were also made by ISO's Short-Wave Spectrometer SWS, the Long-Wave Spectrometer LWS, and the ISOPHOT spectrometer PHOT-S. Results are due for publication at the end of March. They will give details about the composition

  14. CNEN, IAEA and ISO normative requirements for measurement management

    International Nuclear Information System (INIS)

    Kibrit, Eduardo

    2009-01-01

    International standard ISO 10012:2003 establishes requirements for measurement management systems, including requirements for measurement processes and measuring equipment. ISO 9001:2008 presents requirements for quality management systems, including requirements for the control of monitoring and measuring equipment. ISO 17025:2005 presents general requirements for the competence of testing and calibration laboratories. In the nuclear field the requirements for measurement management are established by standards published by the International Atomic Energy Agency (IAEA), and in Brazil, by the National Nuclear Energy Commission (CNEN). The present paper presents and discusses the normative requirements for measurement management, considering requirements established by National Nuclear Energy Commission (CNEN), International Atomic Energy Agency (IAEA), and International Organisation for Standardisation (ISO). (author)

  15. Infra-slow oscillation (ISO of the pupil size of urethane-anaesthetised rats.

    Directory of Open Access Journals (Sweden)

    Tomasz Blasiak

    Full Text Available Multiplicity of oscillatory phenomena in a range of infra-slow frequencies (<0.01 Hz has been described in mammalian brains at different levels of organisation. The significance and manifestation in physiology and/or behaviour of many brain infra-slow oscillations (ISO remain unknown. Examples of this phenomenon are two types of ISO observed in the brains of urethane-anaesthetised rats: infra-slow, rhythmic changes in the rate of action potential firing in a few nuclei of the subcortical visual system and a sleep-like cycle of activation/deactivation visible in the EEG signal. Because both of these rhythmic phenomena involve brain networks that can influence autonomic nervous system activity, we hypothesised that these two brain ISOs can be reflected by rhythmic changes of pupil size. Thus, in the present study, we used simultaneous pupillography and ECoG recording to verify the hypothesised existence of infra-slow oscillations in the pupil size of urethane-anaesthetised rats. The obtained results showed rhythmic changes in the size of the pupils and rhythmic eyeball movements in urethane-anaesthetised rats. The observed rhythms were characterised by two different dominant components in a range of infra-slow frequencies. First, the long component had a period of ≈ 29 minutes and was present in both the irises and the eyeball movements. Second, the short component had a period of ≈ 2 minutes and was observed only in the rhythmic constrictions and dilations of the pupils. Both ISOs were simultaneously present in both eyes, and they were synchronised between the left and right eye. The long ISO component was synchronised with the cyclic alternations of the brain state, as revealed by rhythmic changes in the pattern of the ECoG signal. Based on the obtained results, we propose a model of interference of ISO present in different brain systems involved in the control of pupil size.

  16. Intra-seasonal Oscillations (ISO of zonal-mean meridional winds and temperatures as measured by UARS

    Directory of Open Access Journals (Sweden)

    F. T. Huang

    2005-06-01

    Full Text Available Based on an empirical analysis of measurements with the High Resolution Doppler Imager (HRDI on the UARS spacecraft in the upper mesosphere (95km, persistent and regular intra-seasonal oscillations (ISO with periods of about 2 to 4 months have recently been reported in the zonal-mean meridional winds. Similar oscillations have also been discussed independently in a modeling study, and they were attributed to wave-mean-flow interactions. The observed and modeled meridional wind ISOs were largely confined to low latitudes. We report here on an analysis of concurrent UARS temperature measurements, which produces oscillations similar to those seen in the meridional winds. Although the temperature oscillations are observed at lower altitudes (55km, their phase variations with latitude are qualitatively consistent with the inferred properties seen in the meridional winds and thus provide independent evidence for the existence of ISOs in the mesosphere.

  17. Predictor-Based Model Reference Adaptive Control

    Science.gov (United States)

    Lavretsky, Eugene; Gadient, Ross; Gregory, Irene M.

    2010-01-01

    This paper is devoted to the design and analysis of a predictor-based model reference adaptive control. Stable adaptive laws are derived using Lyapunov framework. The proposed architecture is compared with the now classical model reference adaptive control. A simulation example is presented in which numerical evidence indicates that the proposed controller yields improved transient characteristics.

  18. Die bestuur en opleiding van SABS ISO 9000 reeks

    OpenAIRE

    2014-01-01

    With the lifting of sanctions, South African businesses are faced with a new challenge to compete against their international counterparts on the international and domestic markets. Competing on the international markets is dependant on conforming to a recognised quality management system standard such as ISO 9000 (ISO International Standards Organisation). The South African equivalent for this standard is SABS ISO 9000. (SABS - South African Bureau of Standards). It is thus important for Sou...

  19. Harnessing ISO/IEC 12207 to Examine the Extent of SPI Activity in an Organisation

    Science.gov (United States)

    Clarke, Paul; O'Connor, Rory

    The quality of the software development process directly affects the quality of the software product. To be successful, software development organisations must respond to changes in technology and business circumstances, and therefore software process improvement (SPI) is required. SPI activity relates to any modification that is performed to the software process in order to improve an aspect of the process. Although multiple process assessments could be employed to examine SPI activity, they present an inefficient tool for such an examination. This paper presents an overview of a new survey-based resource that utilises the process reference model in ISO/IEC 12207 in order to expressly and directly determine the level of SPI activity in a software development organisation. This survey instrument can be used by practitioners, auditors and researchers who are interested in determining the extent of SPI activity in an organisation.

  20. Gloss uniformity measurement update for ISO/IEC 19751

    Science.gov (United States)

    Ng, Yee S.; Cui, Chengwu; Kuo, Chunghui; Maggard, Eric; Mashtare, Dale; Morris, Peter

    2005-01-01

    To address the standardization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standardization committee for office equipment chartered the W1.1 project with the responsibility of drafting a proposal for an international standard for the evaluation of printed image quality1. An ISO draft Standard2, ISO/WD 19751-1, Office Equipment - Appearance-based image quality standards for printers - Part 1: Overview, Procedure and Common Methods, 2004 describes the overview of this multi-part appearance-based image quality standard. One of the ISO 19751 multi-part Standard"s tasks is to address the appearance-based gloss and gloss uniformity issues (in ISO 19751-2). This paper summarizes the current status and technical progress since the last two updates3, 4. In particular, we will be discussion our attempt to include 75 degree gloss (G75) objective measurement5 in differential gloss and within-page gloss uniformity. The result for a round-robin experiment involving objective measurement of differential gloss using G60 and G75 gloss measurement geometry is described. The results for two perceptual-based round-robin experiments relating to haze effect on the perception of gloss, and gloss artifacts (gloss streaks/bands, gloss graininess/mottle) are discussed.

  1. Top-Down Enterprise Application Integration with Reference Models

    Directory of Open Access Journals (Sweden)

    Willem-Jan van den Heuvel

    2000-11-01

    Full Text Available For Enterprise Resource Planning (ERP systems such as SAP R/3 or IBM SanFrancisco, the tailoring of reference models for customizing the ERP systems to specific organizational contexts is an established approach. In this paper, we present a methodology that uses such reference models as a starting point for a top-down integration of enterprise applications. The re-engineered models of legacy systems are individually linked via cross-mapping specifications to the forward-engineered reference model's specification. The actual linking of reference and legacy models is done with a methodology for connecting (new business objects with (old legacy systems.

  2. Reference hearing threshold levels for short duration signals

    DEFF Research Database (Denmark)

    Poulsen, Torben; Legarth, Søren Vase

    2008-01-01

    for the determination of reference hearing threshold levels. The results are given as peak-to-peak equivalent threshold sound pressure levels (peETSPL). The results are in good agreement with other sparse results from literature and are part of the basis for the ISO 389-6 standard from 2007....

  3. The Relationship between the Training Function and ISO-9000 Registration.

    Science.gov (United States)

    Maxwell, Randy C.; Jost, Karen L.

    ISO 9000 is one of a series of international standards providing guidelines and governing quality of products and services. The ISO 9000 certification demonstrates the capability of a supplier to control the processes that determine the acceptability of the product or service being supplied. This paper focuses on the training aspects of ISO 9000…

  4. API and ISO standards can be combined

    International Nuclear Information System (INIS)

    Weightman, R.T.; Warnack, M.F.

    1992-01-01

    This paper reports that oil field equipment and product manufacturers can maintain a competitive advantage and minimize costs by integrating American Petroleum Institute (API) licensing programs with International Standards Organization (ISO) 9001 standards under one quality system. A combined quality system approach can position a company for quality system certification under ISO 9001 while maintaining API specifications. Furthermore, only one quality system manual is needed for API licensing and ISO certification, avoiding duplication of effort. The benefits of a documented quality program include the flowing: Job descriptions and personnel qualification requirements are documented; The improved documentation allows direct tracing of specific production activities; Laboratory test methods and calibration of test equipment follow accepted standards for more reliable and reproducible test data; Quality control becomes proactive, not reactive, through internal process controls previously not implemented; Employee attitudes improve through appreciation for the overall goals of the company; Ambiguous quality issues, such as documenting special customer requirements, are easily resolved; and The company image improves with customers, particularly for those that require API Specification Q1 or ISO 9001 compliance or those having their own quality performance standards

  5. From waste minimization to ISO 14000: Taiwan`s experience and prospects

    Energy Technology Data Exchange (ETDEWEB)

    Wen-Huei Chen; Wain-Sun Hou [China Technical Consultants, Inc., Taipei (Taiwan, Province of China)

    1996-12-31

    Taiwan has completed a very successful five-year industrial waste minimization (IWM) demonstration and promotion project sponsored by the government. From 1990 to 1995, the project successfully disseminated the IWM concept of pollution prevention (P2) to industries. It effectively reduced industrial waste while significantly benefitting the economy by assisting industries in implementing in-plant IWM programs. In July 1995, the second stage of the five-year IWM and ISO 14000 promotion project was initiated for further promoting the IWM, P2, and cleaner production and, in particular, coping with the upcoming international environmental management standards (ISO 14000). To assist industries in establishing an environmental management system (EMS) and accumulating related experience, an EMS pilot demonstration project of five model industries and an ISO 14001 EMS demonstration and promotion project for 22 factories in 13 industries were initiated in October 1995 and August 1996, respectively. These projects can assist Taiwan`s industries in changing the constitution of their enterprises, enhancing competition in the international market, and helping our nation achieve the forerunner`s profits in sustainable development. 9 refs., 3 figs.

  6. Experience with ISO quality control in assisted reproductive technology.

    Science.gov (United States)

    Alper, Michael M

    2013-12-01

    Assisted reproductive technology (ART) programs are complex organizations requiring the integration of multiple disciplines. ISO 9001:2008 is a quality management system that is readily adaptable to an ART program. The value that ISO brings to the entire organization includes control of documents, clear delineation of responsibilities of staff members, documentation of the numerous processes and procedures, improvement in tracking and reducing errors, and overall better control of systems. A quality ART program sets quality objectives and monitors their progress. ISO provides a sense of transparency within the organization and clearer understanding of how service is provided to patients. Most importantly, ISO provides the framework to allow for continual improvement. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  7. Strategy for infrared photometry of comets with ISO

    Science.gov (United States)

    Solc, M.; Vanysek, V.; Gruen, E.

    1994-07-01

    The launch of the ISO (Infrared Satellite Observatory) by the European Space Agency is scheduled for autumn 1995. Photometry and spectrophotometry observing programs of comets in the wavelength range 2.5-200 microns for the onboard spectrophotometer ISOPHOT is now under final preparation. Technical details for preparing propasals are given. Phenomena in comets to be studied are surface properties of bare cometary nuclei at large heliocentric distances, onset of coma activity, and coma dust and gas emission (in inner solar system). Dust production, dust/gas mass ratio, dust distribution in coma, and their temporal variability are important for understanding the physical processes on nuclei, and spectrophotometry in the range of 2.5-12 microns could provide us with data of the chemical composition of cometary dust. Several active comets expected for the 18-month lifetime of ISO in 1995-1997 were selected for the ISO Central Program according to their orbital and physical parameters: P/Schwassman-Wachmann 1, P/Encke, P/d'Arrest, P/Honda-Mrkos-Pajdusakova, P/Churyumov-Gerasimenko, P/Kopff, P/IRAS, P/Wirtanen, P/Wild 2, P/Grigg-Skjellerup, P/Schwassman-Wachmann 3, P/Machholz, and (2060) Chiron. Four of them match well various constraints put on the observations by the technical arrangement of the satellite and instrument. A simple four-parameter model (size, albedo, rotation, optical thickness)was developed to estimate the temperatures and thermal fluxes of both solid nuclei and dust coma.

  8. The European large area ISO survey - III. 90-mu m extragalactic source counts

    DEFF Research Database (Denmark)

    Efstathiou, A.; Oliver, S.; Rowan-Robinson, M.

    2000-01-01

    We present results and source counts at 90 mum extracted from the preliminary analysis of the European Large Area ISO Survey (ELAIS). The survey covered about 12 deg(2) of the sky in four main areas and was carried out with the ISOPHOT instrument onboard the Infrared Space Observatory (ISO...... or small groups of galaxies, suggesting that the sample may include a significant fraction of luminous infrared galaxies. The source counts extracted from a reliable subset of the detected sources are in agreement with strongly evolving models of the starburst galaxy population....

  9. Reference model for apparel product development

    Directory of Open Access Journals (Sweden)

    Isabel Cristina Moretti

    2017-03-01

    Full Text Available The purpose of this paper was to develop a reference model for the implementation of the process of product development (PDP for apparel. The tool was developed through an interactive process of comparison between theoretical. Managers in companies and professionals working in this market can utilize the reference model as a source for the organization and improvement of the PDP for apparel and the universities as a reference source for systematized teaching of this process. This model represents the first comprehensive attempt to develop an instrument at a detailed level (macro phases, phases, activities, inputs and outputs at each stage and at the gates to systematize the PDP process for fashion products and to consider its particularities.

  10. FROM QUALITY GURUS AND TQM TO ISO 9001:2015: A REVIEW OF SEVERAL QUALITY PATHS

    Directory of Open Access Journals (Sweden)

    Luís Miguel Fonseca

    2015-03-01

    Full Text Available A revision of several paths for the Quality journey is presented: from Quality Gurus and Total Quality Management (TQM models to the ISO 9000 International Standards Series. Since ISO 9001:2008 is now in the revision process to the expected ISO 9001:2015 version, an analysis is made of he proposed changes and the underlying reasons and the impacts foreseen on the more than 1.3 Million certified organizations. This revision should be a step towards TQM and reflect the changes of an increasingly complex, demanding and dynamic environment, while assuring that complying organizations are able to provide conformity products and services that satisfy their customers. Major benefits are expected such as less emphasis on documentation and new/reinforced approaches: consideration of Organizational Context and (relevant Stakeholders, Risk Based thinking and Knowledge Management. Comments and recommendations are presented for organizations wishing to implement or update their Quality Systems accordingly to ISO 9001:2015.

  11. Effects of Cooking End-point Temperature and Muscle Part on Sensory ‘Hardness’ and ‘Chewiness’ Assessed Using Scales Presented in ISO11036:1994

    Directory of Open Access Journals (Sweden)

    Keisuke Sasaki

    2013-10-01

    Full Text Available Texture and ‘tenderness’ in particular, is an important sensory characteristic for consumers’ satisfaction of beef. Objective and detailed sensory measurements of beef texture have been needed for the evaluation and management of beef quality. This study aimed to apply the sensory scales defined in ISO11036:1994 to evaluate the texture of beef. Longissimus and Semitendinosus muscles of three Holstein steers cooked to end-point temperatures of 60°C and 72°C were subjected to sensory analyses by a sensory panel with expertise regarding the ISO11036 scales. For the sensory analysis, standard scales of ‘chewiness’ (9-points and ‘hardness’ (7-points were presented to the sensory panel with reference materials defined in ISO11036. As a result, both ‘chewiness’ and ‘hardness’ assessed according to the ISO11036 scales increased by increasing the cooking end-point temperature, and were different between Longissimus and Semitendinosus muscles. The sensory results were in good agreement with instrumental texture measurements. However, both texture ratings in this study were in a narrower range than the full ISO scales. For beef texture, ISO11036 scales for ‘chewiness’ and ‘hardness’ are useful for basic studies, but some alterations are needed for practical evaluation of muscle foods.

  12. Verification of SAP reference models

    NARCIS (Netherlands)

    Dongen, van B.F.; Jansen-Vullers, M.H.; Aalst, van der W.M.P.; Benatallah, B.; Casati, F.

    2005-01-01

    To configure a process-aware information system (e.g., a workflow system, an ERP system), a business model needs to be transformed into an executable process model. Due to similarities in these transformations for different companies, databases with reference models, such as ARIS for MySAP, have

  13. Effect of lactobacillus acidophilus combined with iso-malto-oligosaccharide on the intestinal mucosal secretion of SlgA in rat models with antibiotic-associated diarrhea (AAD)

    Energy Technology Data Exchange (ETDEWEB)

    Dan, Du; Lichao, Fang; Bingbo, Chen; Hong, Wei [Third Military Medical Univ., Chongqing (China). Laboratory Animal Center

    2005-02-15

    Objective: To investigate the corrective effect of synbiotic (Lactobacillus acidophilus combined with iso-malto-oligosaccharide) on the decreased intestinal mucosal secretion of SlgA in rat models with antibiotic-associated diarrhea (AAD). Methods: Rat models of AAD were prepared with lincomycin gavage for 6 days. One group of models were left with natural recovery and three other groups were given gavage with different strengths of synbiotic for 7 days. In each group, stool specimens were taken from 6-8 rats for flora examination, then the animals sacrificed and intestinal mucus contents of SIgA determined (with RIA) on d6, d9 and d13. Results: The intestinal flora in rat models of AAD was greatly altered with marked reduction in probiotics. Also, the intestinal mucus contents of SIgA were significantly decreased. Treatment with different strengths of synbiotic (Lactobacillus acidophilus combined with iso-malto-oligosaccharide) would significantly improve the condition with SIgA contents approaching normal. Conclusion: Synbiotic treatment could increase the intestinal mucosal secretion of SIgA with restoration of the mucosal immuno-barrier function in rat models with AAD. (authors)

  14. Effect of lactobacillus acidophilus combined with iso-malto-oligosaccharide on the intestinal mucosal secretion of SlgA in rat models with antibiotic-associated diarrhea (AAD)

    International Nuclear Information System (INIS)

    Du Dan; Fang Lichao; Chen Bingbo; Wei Hong

    2005-01-01

    Objective: To investigate the corrective effect of synbiotic (Lactobacillus acidophilus combined with iso-malto-oligosaccharide) on the decreased intestinal mucosal secretion of SlgA in rat models with antibiotic-associated diarrhea (AAD). Methods: Rat models of AAD were prepared with lincomycin gavage for 6 days. One group of models were left with natural recovery and three other groups were given gavage with different strengths of synbiotic for 7 days. In each group, stool specimens were taken from 6-8 rats for flora examination, then the animals sacrificed and intestinal mucus contents of SIgA determined (with RIA) on d6, d9 and d13. Results: The intestinal flora in rat models of AAD was greatly altered with marked reduction in probiotics. Also, the intestinal mucus contents of SIgA were significantly decreased. Treatment with different strengths of synbiotic (Lactobacillus acidophilus combined with iso-malto-oligosaccharide) would significantly improve the condition with SIgA contents approaching normal. Conclusion: Synbiotic treatment could increase the intestinal mucosal secretion of SIgA with restoration of the mucosal immuno-barrier function in rat models with AAD. (authors)

  15. On the composition of ISO 25964 hierarchical relations (BTG, BTP, BTI)

    NARCIS (Netherlands)

    Alexiev, A; Isaac, A.H.J.C.A.; Lindenthal, J

    2015-01-01

    Knowledge organization systems (KOS) can use different types of hierarchical relations: broader generic (BTG), broader partitive (BTP), and broader instantial (BTI). The latest ISO standard on thesauri (ISO 25964) has formalized these relations in a corresponding OWL ontology (De Smedt et al., ISO

  16. ISO 14000 information platform. Quarterly report, January 1--March 31, 1998

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    GETE, through its ISO 14000 Information Platform, globeNet{trademark} (www.iso14000.net), seeks to provide FETC and the US Department of Energy (DOE) with a timely, accurate, and reliable information resource on the issue of environmental management standards. This resource allows FETC to keep track of the latest developments in the ISO 14000 arena, in DOE as well as throughout the federal complex and industry. Utilizing this information, FETC and DOE can make critical decisions on their own use and implementation of the ISO 14000 standards. The information platform also provides FETC with a forum to present information on its activities, such as the DOE ISO 14000 Pilot Projects, and as an information gathering and dissemination resource for its publications. GETE works with an array of national and international contacts and content sources to gather information and provide daily updates on ISO 14000 and related environmental management issues.

  17. The Use of Reference Models in Business Process Renovation

    Directory of Open Access Journals (Sweden)

    Dejan Pajk

    2010-01-01

    Full Text Available Enterprise resource planning (ERP systems are often used by companies to automate and enhance their busi- ness processes. The capabilities of ERP systems can be described by best-practice reference models. The purpose of the article is to demonstrate the business process renovation approach with the use of reference models. Although the use of reference models brings many positive effects for business, they are still rarely used in Slovenian small and medium-sized compa- nies. The reasons for this may be found in the reference models themselves as well as in project implementation methodologies. In the article a reference model based on Microsoft Dynamics NAV is suggested. The reference model is designed using upgraded BPMN notation with additional business objects, which help to describe the models in more detail.

  18. ISO 9001 certification for hospitals in Bulgaria: does it help service?

    Science.gov (United States)

    Stoimenova, Assena; Stoilova, Ani; Petrova, Guenka

    2014-03-04

    The aim of our study is to review the published literature on establishment and implementation of ISO 9001 QMS in European hospitals, to study the availability of International Organization for Standardization (ISO) quality management systems (QMS) in Bulgarian hospitals and to outline the main advantages of ISO implementation in the hospitals in Bulgaria. The information on availability of ISO QMS in the hospitals in Bulgaria was gathered via Bulgarian certification register, the registries of various quality associations, websites of hospitals and certification companies presented in Bulgaria. A total number of 312 hospitals in Bulgaria were screened for the availability of QMS certified against the ISO 9001 requirements. The experience of European hospitals that implemented QMS is positive and the used approaches to improve the processes and the demonstrated effects from ISO implementation are analysed by the researchers. Unlike other European Union member states, the establishment of quality management systems in Bulgaria is not compulsory. However, our study revealed that 14.42% of the hospitals in Bulgaria have implemented and have certified quality systems against the requirements of ISO 9001. Our study confirmed that a quality management system using the ISO 9001 standard is useful for the hospitals as it can help to increase the operational efficiencies, to reduce errors, improve patient safety and produce a more preventive approach instead of a reactive environment.

  19. The dark side of ISO 14001: The symbolic environmental behavior

    Directory of Open Access Journals (Sweden)

    Vera Ferrón Vílchez

    2017-01-01

    Full Text Available Some of the academic research on ISO 14001 has focused on analyzing the benefits of its adoption. However, this international standard has also received some criticism, particularly in respect of the adoption of ISO 14001 when not accompanied by significant improvements in environmental performance. This study analyzes the relationship between the symbolic environmental behavior and the adoption of ISO 14001. In so doing, it uses binary logistic regression to analyze an international sample of 1961 manufacturing facilities that each employs more than 50 people. The results indicate that the higher the symbolic environmental performance of the firm, the greater the probability of adopting ISO 14001.

  20. Business Model for the Security of a Large-Scale PACS, Compliance with ISO/27002:2013 Standard.

    Science.gov (United States)

    Gutiérrez-Martínez, Josefina; Núñez-Gaona, Marco Antonio; Aguirre-Meneses, Heriberto

    2015-08-01

    Data security is a critical issue in an organization; a proper information security management (ISM) is an ongoing process that seeks to build and maintain programs, policies, and controls for protecting information. A hospital is one of the most complex organizations, where patient information has not only legal and economic implications but, more importantly, an impact on the patient's health. Imaging studies include medical images, patient identification data, and proprietary information of the study; these data are contained in the storage device of a PACS. This system must preserve the confidentiality, integrity, and availability of patient information. There are techniques such as firewalls, encryption, and data encapsulation that contribute to the protection of information. In addition, the Digital Imaging and Communications in Medicine (DICOM) standard and the requirements of the Health Insurance Portability and Accountability Act (HIPAA) regulations are also used to protect the patient clinical data. However, these techniques are not systematically applied to the picture and archiving and communication system (PACS) in most cases and are not sufficient to ensure the integrity of the images and associated data during transmission. The ISO/IEC 27001:2013 standard has been developed to improve the ISM. Currently, health institutions lack effective ISM processes that enable reliable interorganizational activities. In this paper, we present a business model that accomplishes the controls of ISO/IEC 27002:2013 standard and criteria of security and privacy from DICOM and HIPAA to improve the ISM of a large-scale PACS. The methodology associated with the model can monitor the flow of data in a PACS, facilitating the detection of unauthorized access to images and other abnormal activities.

  1. [Certification of an ambulatory gastroenterologic service fulfilling ISO Law 9001--criteria and national guidelines of the Gastroenterologic Association].

    Science.gov (United States)

    Birkner, B

    2000-09-01

    The objectives of certification and accreditation are the deployment and examination of quality improvement measures in health care services. The quality management system of the ISO 9001 is created to install measures and tools leading to assured and improved quality in health care. Only some experiences with certification fulfilling ISO 9001 criteria exist in the German health care system. Evidence-based clinical guidelines can serve as references for the development of standards in quality measurement. Only little data exists on the implementation strategy of guidelines and evaluation, respectively. A pilot quality management system in consistence with ISO 9001 criteria was developed for ambulatory, gastroenterological services. National guidelines of the German Society of Gastroenterology and Metabolism and the recommendations of the German Association of Physicians for quality assurance of gastrointestinal endoscopy were included in the documentation and internal auditing. This pilot quality management system is suitable for the first steps in the introduction of quality management in ambulatory health care. This system shows validity for accreditation and certification of gastrointestinal health care units as well.

  2. ISO certification pays off in quality improvement

    International Nuclear Information System (INIS)

    Vermeer, F.J.G.

    1992-01-01

    This paper reports that by obtaining and maintaining International Standards Organization (ISO) 9001 certification, a company can improve its quality control system, cut waste, and motivate its employees. In so doing it improves its competitive position in both international and domestic markets. The success of a number of countries (notably Japan) in the world markets has focused the attention of the industrialized countries on improving quality levels and striving for a unified, worldwide quality standard. This has been particularly true in Europe; with several countries competing in a single market, a common quality standard has been a highly desirable goal for decades. One of the first multinational quality standards evolved in the European Community, which is estimated to become a single market with a gross national product of $4.5 trillion by 1992. As a consequence, in 1987 the International Standards Organization created ISO 9000, a single standard to ensure uniform quality in products and services offered with this growing market. U.S. petroleum and natural gas companies must recognize and implement the ISO 9000 standards or possibly lose international markets. If the present worldwide trend towards ISO 9000 continues (and there is no reason to believe that it will not), the standards will be just as important in the domestic market

  3. AN INITIAL DESIGN OF ISO 19152:2012 LADM BASED VALUATION AND TAXATION DATA MODEL

    DEFF Research Database (Denmark)

    Cagdas, Volkan; Kara, A.; van Oosterom, P.

    2016-01-01

    standard that defines the semantics of fiscal databases. The ISO 19152:2012 Land Administration Domain Model (LADM), as an international land administration standard focuses on legal requirements, but considers out of scope specifications of external information systems including valuation and taxation...... databases. However, it provides a formalism which allows for an extension that responds to the fiscal requirements. This paper introduces an initial version of a LADM – Fiscal Extension Module for the specification of databases used in immovable property valuation and taxation. The extension module....... It is expected that the initial version will be refined through further activities held by a possible joint working group under FIG Commission 7 (Cadastre and Land Management) and FIG Commission 9 (Valuation and the Management of Real Estate) in collaboration with other relevant international bodies....

  4. Integrating the augmented SCOR model and the ISO 15288 life cycle model into a single logistic model

    CSIR Research Space (South Africa)

    Schmitz, Peter MU

    2010-07-01

    Full Text Available using the Supply Chain Operations Reference (SCOR) model. The SANDF indicated that the augmented SCOR model (Bean, Schmitz and Engelbrecht, 2009) should be extended into a single logistics process which should include a life-cycle perspective...

  5. ISO 14000: Origin, Structure, and Potential Barriers to Implementation.

    Science.gov (United States)

    Casto; Ellisen; Trnovec; Kross; Ginter

    1996-04-01

    The ISO 14000 is likely to become the international standard for environmental management. At present, it is an evolving series of individual voluntary standards and guideline reference documents that provide business management with the structure for managing environmental impacts. These encompass environmental management systems, environmental audits, eco-labeling, environmental performance evaluations, life-cycle assessment, and environmental aspects in product standards. The authors present the rationale for the ISO 14000 and the steps in its evolution so far, as well as its present provisions and their implications and its position with regard to regulatory agencies. Particular attention is paid to the consequences of voluntary disclosure and correction of violations. Hanley & Belfus, Inc. Int J Occup Environ Health 1077-3525 2 2 1996 April/June Perspectives on Rural Environmental Health in Central Europe 125 134 EN Tomas Trnovec Burton C. Kross CIREH-Room 352, International Center, University of Iowa, Iowa City, IA 52242, USA. Emil Ginter Life expectancy is about five to seven years less in Central European countries than in comparable countries in Western Europe. Environmental and occupational health risk factors, along with the socioeconomic and political conditions that have prevailed in this region for the past 40 years, are suspected contributing factors to this condition. The initial impression among observers was that environmental pollution by industry was the primary source of contamination leading to human health effects. Current thinking by the authors recognizes that combinations of personal habits, local environmental emissions (home heating), and occupational risk factors are more likely to be influencing the health of this region, particularly in rural areas. A predictive model for standard mortality rates determined that only three potential risk factors were statistically significant: consumption of alcoholic beverages, consumption of citrus

  6. The impact of ISO 14000 on developing world businesses

    International Nuclear Information System (INIS)

    Mohamed, S.T.

    2001-01-01

    ISO 14000 has attracted interest from industry, international organizations and governments around the globe. Policy-makers and industry both appear to be looking to the standards as a key component of a new paradigm for cooperation between regulators and industry. This realization seems to have resulted from a growing awareness that the fragmented, reactive approach to environmental management in the past has not produced optimal results. Businesses are realizing the value of integrating their compliance procedures for each regulation into a broader system. Compliance problems can often be linked to system problems such as inadequate training, lack of responsibility at the right level, inadequate data, and other related causes. An effective Environmental Management System (EMS) eliminates these pitfalls. The evolution of the EMS is being shaped by market forces, ISO 9000, regulatory shifts, public awareness, and cost implications for ISO certifications. The transformation of these management practices is not limited to industrialized countries. In anticipation of the non-tariff trade barriers that could be erected as a result of these standards, many developing countries are seeking avenues of compliance with ISO 14000's requirements. Egypt should be concerned with the implementation of this system, for firms in countries of the European Community (EC) have been given explicit instructions by the three prevalent European standard-setting organizations to ''familiarize'' themselves with the requirements of ISO 14000. This paper will focus primarily on the expected effects of ISO 14001. (author)

  7. Persian Agricultural Journals and Standard: Degree of Compatibility of Persian Scientific Agricultural Journals with International Standard Organization (ISO Publishing standards

    Directory of Open Access Journals (Sweden)

    Abbas Gilvari

    2011-10-01

    Full Text Available Standard is a collection of recipes, guidelines or recommendations which use in production, creating or making of goods, products, documents or special resources. Extent of adaptation of Persian Agricultural scientific journals which are publishing in Iran with ISO publishing standards was evaluated in this research. The information items which were necessary to be presented in different sections of Agricultural scientific journals were examined. Items which were needed to be present in cover page, content, title page, running title, and endnote, abstract, first page of an article, references and its structure were among the information items. 47 Agricultural scientific journals were publishing until February 2009 consisted of the research population. Descriptive survey method is used. Results showed the adaption rate with ISO standards in research population was 53.47 percent. There was no private publisher which publishes agricultural scientific journals. The extent of adaptation with ISO standards was high in journal sections such as abstracts and keywords.

  8. Characterization of Slosh Damping for Ortho-Grid and Iso-Grid Internal Tank Structures

    Science.gov (United States)

    Westra, Douglas G.; Sansone, Marco D.; Eberhart, Chad J.; West, Jeffrey S.

    2016-01-01

    Grid stiffened tank structures such as Ortho-Grid and Iso-Grid are widely used in cryogenic tanks for providing stiffening to the tank while reducing mass, compared to tank walls of constant cross-section. If the structure is internal to the tank, it will positively affect the fluid dynamic behavior of the liquid propellant, in regard to fluid slosh damping. As NASA and commercial companies endeavor to explore the solar system, vehicles will by necessity become more mass efficient, and design margin will be reduced where possible. Therefore, if the damping characteristics of the Ortho-Grid and Iso-Grid structure is understood, their positive damping effect can be taken into account in the systems design process. Historically, damping by internal structures has been characterized by rules of thumb and for Ortho-Grid, empirical design tools intended for slosh baffles of much larger cross-section have been used. There is little or no information available to characterize the slosh behavior of Iso-Grid internal structure. Therefore, to take advantage of these structures for their positive damping effects, there is much need for obtaining additional data and tools to characterize them. Recently, the NASA Marshall Space Flight Center conducted both sub-scale testing and computational fluid dynamics (CFD) simulations of slosh damping for Ortho-Grid and Iso-Grid tanks for cylindrical tanks containing water. Enhanced grid meshing techniques were applied to the geometrically detailed and complex Ortho-Grid and Iso-Grid structures. The Loci-STREAM CFD program with the Volume of Fluid Method module for tracking and locating the water-air fluid interface was used to conduct the simulations. The CFD simulations were validated with the test data and new empirical models for predicting damping and frequency of Ortho-Grid and Iso-Grid structures were generated.

  9. Iso-α-acids, bitter components of beer, prevent obesity-induced cognitive decline.

    Science.gov (United States)

    Ayabe, Tatsuhiro; Ohya, Rena; Kondo, Keiji; Ano, Yasuhisa

    2018-03-19

    Dementia and cognitive decline have become worldwide public health problems, and it was recently reported that life-style related diseases and obesity are key risk factors in dementia. Iso-α-acids, hop-derived bitter components of beer, have been reported to have various physiological functions via activation of peroxisome proliferator-activated receptor γ. In this report, we demonstrated that daily intake of iso-α-acids suppresses inflammations in the hippocampus and improves cognitive decline induced by high fat diet (HFD). Body weight, epididymal fat weight, and plasma triglyceride levels were increased in HFD-fed mice, and significantly decreased in iso-α-acids supplemented HFD-fed mice. HFD feeding enhances the production of inflammatory cytokines and chemokines, such as TNF-α, which was significantly suppressed by iso-α-acids administration. HFD-induced neuroinflammation caused lipid peroxidation, neuronal loss, and atrophy in hippocampus, and those were not observed in iso-α-acids-treated mice. Furthermore, iso-α-acids intake significantly improved cognitive decline induced by HFD-feeding. Iso-α-acids are food derived components that suppressing both lipid accumulation and brain inflammation, thus iso-α-acids might be beneficial for the risk of dementia increased by obesity and lifestyle-related diseases.

  10. New water and remote galaxies complete ISO's observations

    Science.gov (United States)

    ISO's operational teams at ESA's ground station at Villafranca near Madrid have been hurrying to provide the world's astronomers with as many observations as possible. They have long anticipated the exhaustion of ISO's vital supply of liquid helium, which cooled the infrared telescope and its instruments to their operating temperatures, close to absolute zero. Two weeks after ISO was put into orbit on 17 November 1995 by an Ariane 44P launcher, the external parts of the cooling system had settled to the operating temperature. The specification required that ISO should then operate for at least 18 months -- implying that operations might have to end in May 1997. Thanks to superb engineering by European industry, which built the spacecraft and its super-cool telescope, ISO has given astronomers almost a year longer than that. During the extra time the count of ISO's observations of cosmic objects has risen from 16,000 to about 26,000. Among the benefits of ISO's longevity has been the chance to examine an important region of the sky, in and around the constellation of Orion. This was not accessible in the nominal mission but has now been observed in two periods. Four inter national teams, supported by national funding agencies, supplied the instruments to analyse the infrared rays received by ISO's telescope. The principal investigators leading the teams are Dietrich Lemke (Heidelberg, Germany) for the versatile photometer ISOPHOT, Catherine Cesarsky (Saclay, France) for the camera ISOCAM, Thijs de Graauw (Groningen, the Netherlands) for the Short Wavelength Spectrometer SWS, and Peter Clegg (London, UK) for the Long Wavelength Spectrometer LWS. Water vapour on Titan A big difference between ISO and the only previous infrared astronomy satellite (IRAS 1983) has been its ability to examine individual objects across a wide range of accurately defined infrared wavelengths. Many spectra showing patterns of intensities at the different wavelengths have enabled astronomers

  11. Using ISO 25040 standard for evaluating electronic health record systems.

    Science.gov (United States)

    Oliveira, Marília; Novaes, Magdala; Vasconcelos, Alexandre

    2013-01-01

    Quality of electronic health record systems (EHR-S) is one of the key points in the discussion about the safe use of this kind of system. It stimulates creation of technical standards and certifications in order to establish the minimum requirements expected for these systems. [1] In other side, EHR-S suppliers need to invest in evaluation of their products to provide systems according to these requirements. This work presents a proposal of use ISO 25040 standard, which focuses on the evaluation of software products, for define a model of evaluation of EHR-S in relation to Brazilian Certification for Electronic Health Record Systems - SBIS-CFM Certification. Proposal instantiates the process described in ISO 25040 standard using the set of requirements that is scope of the Brazilian certification. As first results, this research has produced an evaluation model and a scale for classify an EHR-S about its compliance level in relation to certification. This work in progress is part for the acquisition of the degree of master in Computer Science at the Federal University of Pernambuco.

  12. Implementation of ISO guide 25 in a medical dosimetry secondary standards calibration laboratory

    International Nuclear Information System (INIS)

    DeWerd, L.A.

    1995-01-01

    Currently, there is a great deal of discussion among industry and government agencies about ISO 9000 accreditation. U.S. manufacturers with ISO 9000 accreditation are regarded more favorably by European countries. The principles behind the ISO 9000 accreditation are based on the Total Quality Management (TQM) principles that are being implemented in many U.S. industries. This paper will deal only with the calibration issue. There is a difference in the areas covered by ISO 9000 and ISO Guide 25 documents. ISO 9000, in particular ISO 9001 - ISO 9003, cover the open-quotes calibrationclose quotes of inspection, measuring and test equipment. This equipment is basically used for open-quotes factory calibrationsclose quotes to determine that equipment is performing within manufacturer specifications. ISO Guide 25 is specifically for open-quotes calibration and testing laboratories,close quotes generally laboratories that have painstaking procedures to reduce uncertainties and establish high accuracy of the transfer of calibration. The experience of the University of Wisconsin Accredited Dosimetry Calibration Laboratory in conforming to ISO Guide 25 will be outlined. The entire laboratory staff must become familiar with the process and an individual with direct authority must become the one to maintain the quality of equipment and calibrations in the role of open-quotes quality-assurance manager.close quotes

  13. Perancangan SMKI Berdasarkan SNI ISO/IEC27001:2013 dan SNI ISO/IEC27005:2013 (Studi Kasus DPTSI-ITS

    Directory of Open Access Journals (Sweden)

    Furqon Mauladani

    2018-03-01

    Full Text Available Institut Teknologi Sepuluh Nopember (ITS adalah salah satu universitas di Surabaya. ITS telah menggunakan TIK untuk keperluan operasional bisnisnya (contohnya isi kartu program studi, proses absensi, pembaharuan informasi, dan lainnya. Penggunaan TIK tidak dapat dipisahkan dari ancaman yang dapat mengganggu operasional TIK. Ancaman terdiri dari ancaman yang berasal dari luar (penyebaran malware, aktifitas social engineering, orang dalam (sengaja, tidak sengaja, kegagalan teknis (kesalahan penggunaan, kegagalan perangkat keras/lunak ataupun bencana alam (kebakaran, gempa, banjir. Metode yang digunakan pada penelitian ini adalah melakukan manajemen resiko keamanan informasi berdasarkan SNI ISO/IEC 27005 dan perancangan dokumen SMKI berdasarkan SNI ISO/IEC 27001. Hasil penelitian ini adalah 60 resiko yang tidak diterima dari total 228 resiko yang telah teridentifikasi. Dari 60 resiko tersebut, terdapat 58 risk modification, 1 risk avoidance, dan 1 risk sharing. Tata kelola keamanan informasi yang dirancang berdasarkan SNI ISO/IEC 27001 adalah ruang lingkup SMKI, kebijakan SMKI, proses penilaian resiko, proses penanganan resiko, statement of applicability, dan sasaran keamanan informasi.

  14. Standardization by ISO to Ensure the Sustainability of Space Activities

    Science.gov (United States)

    Kato, A.; Lazare, B.; Oltrogge, D.; Stokes, H.

    2013-08-01

    The ISO / Technical Committee 20 / Sub-committee 14 develops debris-related standards and technical reports to mitigate debris and help ensure mission and space sustainability. While UN Guidelines and the IADC Guidelines encourage national governments and agencies to promote debris mitigation design and operation, the ISO standards will help the global space industry promote and sustain its space-related business. In this paper the scope and status of each ISO standard is discussed within an overall framework. A comparison with international guidelines is also provided to demonstrate the level of consistency. Finally, as a case study, the ISO standards are applied to a CubeSat mission, thus demonstrating their usability on a relatively recent and popular class of satellite.

  15. Isoe - information system on occupational exposure. Ten years of experience

    International Nuclear Information System (INIS)

    2002-01-01

    The information System on Occupational Exposure (ISOE) was created in 1992 to provide a forum for radiation protection experts from both utilities and national regulatory authorities to discuss, promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The ISOE System is jointly managed by the OECD Nuclear Energy Agency (NEA) and the International Atomic Energy Agency (IAEA). This report provides an overview of the experience gained from, and benefits provided by, the ISOE System over the past ten years. Active participation of a large number of utilities in ISOE has contributed to a reduction in occupational exposure at nuclear power plants worldwide. (authors)

  16. [Efforts to achieve and effects of acquiring ISO 15189 in Tokushima University Hospital].

    Science.gov (United States)

    Shono, Kazuko; Kishi, Misako; Satou, Mituyo; Nagamine, Yasunori; Doi, Tosio

    2009-12-01

    The medical laboratory of Tokushima University Hospital acquired ISO 15189, an international standard for medical laboratories, on July 6th, 2007, resulting in it achieving the 24th place in Japan and 5th place among national university hospitals. The first surveillance was just performed on October 6th, 2008. Tokushima University Hospital, in which our medical laboratory is included as one section, already succeeded in acquiring ISO 9001, PrivacyMark System, and Quality Health Care ver. 5 before accomplishing ISO 15189. To achieve ISO 15189, we prepared documents based on ISO 9001 without any consultation, resulting in a review of the difference between ISO 9001 and ISO 15189 after the preliminary survey. Although achieving ISO 15189 resulted in an improvement in the reliability of laboratory results and accuracy, leading to the development of our technical skills and awareness, and sharing of knowledge, we consider that the considerable investment of time to prepare the requirements remains to be overcome.

  17. Motivational factors for the adoption of ISO 9001 standards in Eastern Europe: the case of Bulgaria

    Directory of Open Access Journals (Sweden)

    Svetoslav Georgiev

    2015-05-01

    Full Text Available Purpose: This study analyzes the motivational factors for ISO 9001 certification in Bulgaria from the internal/external motivations perspective, or the so-called dual model.Design/methodology/approach: This study is based on a mixed method research approach, which employed two interviews with experts in the field of quality management at the exploratory stage, and a survey involving 127 companies at the descriptive stage.Findings: This study claims that enhanced company image and competitiveness – an external motivation - is the leading motivational factor for ISO 9001 certification in Bulgaria. At the same time, our primary investigation reveals that Bulgarian firms are not predominantly externally driven, for internal motivations including process improvement and product quality improvement seem to be an important driver for ISO 9001 certification. Last but not least, this research asserts that enhanced company image and competitiveness has a stronger impact on the motivations for ISO 9001 certification than customer and supplier pressure, which is in line with previous research works on developing economy economies such as Bulgaria. Finally, our study indicates a moderate, yet positive correlation between motivations for and benefits of ISO 9001 certification.Social implications: This research work casts some light on the evolution of quality management in Bulgaria since the end of communism, which can serve as an important foundation for the better understanding of quality management in former communist economies in general and Eastern European states in particular.Originality/value: Derived from the acute gap between ISO studies in Western and former communist economies, this research work presents one of the first official, international studies in the field of ISO certification in Bulgaria, and more precisely, a paper describing the motives for ISO 9001 certification among Bulgarian businesses.

  18. 77 FR 11532 - Notice of Attendance at ISO New England and NEPOOL Meetings

    Science.gov (United States)

    2012-02-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Attendance at ISO New England... members of the Commission and Commission staff may attend upcoming ISO New England Inc. (ISO-NE) and New..., the Commission and Commission staff may monitor the various meetings posted on the ISO-NE Web site...

  19. ISO 14001 ENVIRONMENTL MANAGEMENT SYSTEMS IN GOVERNMENT AND INDUSTRY

    Science.gov (United States)

    Two new USEPA documents address environmental management systems (EMS) from the perspectives of government and industry and are offered as tools for understanding the process of the ISO 14000 Standards development and usefulness of an EMS approach. The first document, ISO 14001 -...

  20. IS ISO 9000 CERTIFICATION LOSING ITS CREDIBILITY?

    Directory of Open Access Journals (Sweden)

    P.R. Ramesh

    2013-03-01

    Full Text Available ISO certification was a great hope for many stakeholders in India for making the country strong in terms of quality practices. It was a blessing in disguise when in early nineties; buyers were imposing conditions that you should be ISO compliant to do business with them. ISO was a great system to bring in improvements in the way an organization functions. But unfortunately some have adopted a short cut approach in getting the certification done. It is only just before the audit team comes for re-inspection that firms start removing dust from the quality manual files so that they can pretend that that they follow those systems. But a real commitment to adhering to these systems is missing. The paper describes such scenario existing in some quarters in India and warns against such practices for the overall good of the system.

  1. ISO Results Presented at International Astronomical Union

    Science.gov (United States)

    1997-08-01

    Some of the work being presented is collected in the attached ESA Information Note N 25-97, ISO illuminates our cosmic ancestry. A set of six colour images illustrating various aspects have also been released and are available at http://www.estec.esa.nl/spdwww/iso1808.htm or in hard copy from ESA Public Relations Paris (fax:+33.1.5369.7690). These pictures cover: 1. Distant but powerful infrared galaxies 2. A scan across the milky way 3. Helix nebula: the shroud of a dead star 4. Supernova remnant Cassiopeia A 5. Trifid nebula: a dusty birthplace of stars 6. Precursors of stars and planets The International Astronomical Union provides a forum where astronomers from all over the world can develop astronomy in all its aspects through international co-operation. General Assemblies are held every three years. It is expected that over 1600 astronomers will attend this year's meeting, which is being held in Kyoto, Japan from 18-30 August. Further information on the meeting can be found at: www.tenmon.or.jp/iau97/ . ISO illuminates our cosmic ancestry The European Space Agency's Infrared Space Observatory, ISO, is unmatched in its ability to explore and analyse many of the universal processes that made our existence possible. We are children of the stars. Every atom in our bodies was created in cosmic space and delivered to the Sun's vicinity in time for the Earth's formation, during a ceaseless cycle of birth, death and rebirth among the stars. The most creative places in the sky are cool and dusty, and opaque even to the Hubble Space Telescope. Infrared rays penetrating the dust reveal to ISO hidden objects, and the atoms and molecules of cosmic chemistry. "ISO is reading Nature's recipe book," says Roger Bonnet, ESA's director of science. "As the world's only telescope capable of observing the Universe over a wide range of infrared wavelengths, ISO plays an indispensable part in astronomical discoveries that help to explain how we came to exist." This Information Note

  2. The Road to Excellence: : A Case Study of the Application of GMP, ISO 9001 and the EFQM Excellence Model in a Nuclear Medicine Department

    NARCIS (Netherlands)

    van Huizen, L; Ahaus, C.T.B. (Kees)

    2017-01-01

    Definitions are introduced to give insight in the field of work of Quality Management in relation to responsibilities in Nuclear Medicine and Molecular Imaging. A relation model visualizes the relationships. When working on the Road to Quality Excellence. The standards as GMP, GCP, ISO 9001 and EFQM

  3. Analytical Performance Requirements for Systems for Self-Monitoring of Blood Glucose With Focus on System Accuracy: Relevant Differences Among ISO 15197:2003, ISO 15197:2013, and Current FDA Recommendations.

    Science.gov (United States)

    Freckmann, Guido; Schmid, Christina; Baumstark, Annette; Rutschmann, Malte; Haug, Cornelia; Heinemann, Lutz

    2015-07-01

    In the European Union (EU), the ISO (International Organization for Standardization) 15197 standard is applicable for the evaluation of systems for self-monitoring of blood glucose (SMBG) before the market approval. In 2013, a revised version of this standard was published. Relevant revisions in the analytical performance requirements are the inclusion of the evaluation of influence quantities, for example, hematocrit, and some changes in the testing procedures for measurement precision and system accuracy evaluation, for example, number of test strip lots. Regarding system accuracy evaluation, the most important change is the inclusion of more stringent accuracy criteria. In 2014, the Food and Drug Administration (FDA) in the United States published their own guidance document for the premarket evaluation of SMBG systems with even more stringent system accuracy criteria than stipulated by ISO 15197:2013. The establishment of strict accuracy criteria applicable for the premarket evaluation is a possible approach to further improve the measurement quality of SMBG systems. However, the system accuracy testing procedure is quite complex, and some critical aspects, for example, systematic measurement difference between the reference measurement procedure and a higher-order procedure, may potentially limit the apparent accuracy of a given system. Therefore, the implementation of a harmonized reference measurement procedure for which traceability to standards of higher order is verified through an unbroken, documented chain of calibrations is desirable. In addition, the establishment of regular and standardized post-marketing evaluations of distributed test strip lots should be considered as an approach toward an improved measurement quality of available SMBG systems. © 2015 Diabetes Technology Society.

  4. IMEKO TC1-TC7 Symposium in London: The assurance as a result of blood chemical analysis by ISO-GUM and QE

    Science.gov (United States)

    Iwaki, Y.

    2010-07-01

    The Quality Assurance (QA) of measurand has been discussed over many years by Quality Engineering (QE). It is need to more discuss about ISO standard. It is mining to find out root fault element for improvement of measured accuracy, and it remove. The accuracy assurance needs to investigate the Reference Material (RM) for calibration and an improvement accuracy of data processing. This research follows the accuracy improvement in field of data processing by how to improve of accuracy. As for the fault element relevant to measurement accuracy, in many cases, two or more element is buried exist. The QE is to assume the generating frequency of fault state, and it is solving from higher ranks for fault factor first by "Failure Mode and Effects Analysis (FMEA)". Then QE investigate the root cause over the fault element by "Root Cause Analysis (RCA)" and "Fault Tree Analysis (FTA)" and calculate order to the generating element of assume specific fault. These days comes, the accuracy assurance of measurement result became duty in the Professional Test (PT). ISO standard was legislated by ISO-GUM (Guide of express Uncertainty in Measurement) as guidance of an accuracy assurance in 1993 [1] for QA. Analysis method of ISO-GUM is changed into Exploratory Data Analysis (EDA) from Analysis of Valiance (ANOVA). EDA calculate one by one until an assurance performance is obtained according to "Law of the propagation of uncertainty". If the truth value was unknown, ISO-GUM is changed into reference value. A reference value set up by the EDA and it does check with a Key Comparison (KC) method. KC is comparing between null hypothesis and frequency hypothesis. It performs operation of assurance by ISO-GUM in order of standard uncertainty, the combined uncertainty of many fault elements and an expansion uncertain for assurance. An assurance value is authorized by multiplying the final expansion uncertainty [2] by K of coverage factor. K-value is calculated from the Effective Free

  5. Qualidade e educação superior: a norma de qualidade para a aprendizagem, educação e formação: ISO/IEC 19796-1 = Quality and Higher Education: the standard ISO/IEC 19796-1 for learning, education and training

    Directory of Open Access Journals (Sweden)

    Viebrantz, Rosalir

    2009-01-01

    Full Text Available Em 2005, uma nova norma de qualidade para a aprendizagem, educação e formação, a ISO/IEC 19796-1, foi publicada. O objetivo desta norma é orientar as organizações educacionais e desenvolver sistemas de qualidade e melhorar a qualidade dos seus processos, produtos e serviços. Este artigo busca entender a norma com base em conceitos de qualidade e na tendência à garantia da qualidade. A ISO/IEC é apresentada de forma sucinta, mostrando a metodologia e suas vantagens para as organizações educacionais. É ressaltado que a norma é um modelo de referência e necessita ser adaptada às necessidades e exigências de cada organização

  6. Revision of the ISO and EN radiation sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.; Hansen, J.

    2002-01-01

    The radiation sterilization standards, ISO 11137 and EN 552, are now being revised under "ISO lead", with the aim of producing only one international standard, although in four parts: (1) requirements. (2) dose-setting methods, (3) dose-substantiation methods and (4) dosimetry. Several aspects...

  7. Evaluation of ISO CRS Envelopes Relative to U.S. Vehicles and Child Restraint Systems.

    Science.gov (United States)

    Hu, Jingwen; Manary, Miriam A; Klinich, Kathleen D; Reed, Matthew P

    2015-01-01

    The objectives of this study are to use computer simulation to evaluate the International Organization for Standardization (ISO) 13216-3:2006(E) child restraint system (CRS) envelopes relative to rear seat compartments from vehicles and CRSs in the U.S. market, investigate the potential compatibility issues of U.S. vehicles and CRSs, and demonstrate whether necessary modifications can be made to introduce such a system into compatibility evaluations between U.S. vehicles and CRSs. Three-dimensional geometry models for 26 vehicles and 16 convertible CRS designs developed previously were used. Geometry models of 3 forward-facing and 3 rear-facing CRS envelopes provided by the ISO were built in the current study. The virtual fit process closely followed the physical procedures described in the ISO standards. The results showed that the current ISO rear-facing envelopes can provide reasonable classifications for CRSs and vehicles, but the forward-facing envelopes do not represent products currently in the U.S. market. In particular, all of the selected vehicles could accommodate the largest forward-facing CRS envelope at the second-row seat location behind the driver seat. In contrast, half of the selected CRSs could not fit within any of the forward-facing ISO CRS envelopes, mainly due to protrusion at the rear-top corner of the envelope. The results also indicate that the rear seat compartment in U.S. vehicles often cannot accommodate a large portion of convertible CRSs in the rear-facing position. The increased demand for vehicle fuel economy and the recommendation to keep children rear-facing longer may lead to smaller cars and larger CRSs, which may increase the potential for fit problems. The virtual classifications indicated that contact between the forward-facing CRSs and the head restraints in the rear seats as well as that between the rear-facing CRSs and the back of the front seats is a main concern regarding the compatibility between the vehicles and the

  8. Errors in the SAP reference model

    NARCIS (Netherlands)

    Mendling, J.; Aalst, van der W.M.P.; Dongen, van B.F.; Verbeek, H.M.W.

    2006-01-01

    The SAP Reference Model is a set of information models that is utilized to guide the configuration of SAP systems. A big part of these models are business process models represented in the Eventdriven Process Chains (EPC) notation. These EPC models provide a easy to comprehend overview of SAP

  9. Implementation of the ISO 9001 quality management system - process, impact and benefits

    Directory of Open Access Journals (Sweden)

    Aleksandar Ž. Drenovac

    2013-10-01

    Full Text Available Modern business is characterized by greater and greater market competition through all business areas and all activities. Establishment of market positions is a very important element of business activities in every organization. Quality of products and/or services provides recognizability at market and raising of ratings. Implementation of the ISO 9001 quality management system opens positions for secure national and international markets; it is also an identifier of an efficiently and effectively process-wise organized system in an organization. Introduction An increase of impact of quality and demands for ensuring quality before contract approvals has been visible lately. All vendors at the multinational market must ensure confidence in the quality of their products or services in order to satisfy customer demands which is an ultimate goal. Organizations which have the certificated ISO 9001 standard are known for their persistence and reliability, so they reach high reputation by applying  the standard. Implementation of a quality management system Implementation of a quality management system is done by system engineering, as a process based on a top management decision. It can be applied through the engagement of professionals from within the organization, as well as through outsourced consultants. The process is based on the PDCA cycle and the eight principles of quality management in an ISO 9001 organization. Defining assignments in accordance with the standard The Quality Manual, as a document which contains quality aims and through which a complete model of the quality management system is described, should be an initial element for the process of implementing a quality management system. It contains an overview of all procedures and directions used for achieving quality policy, i.e. for the implementation of a quality management system in every part of a business system. Implementation of procedures When the Quality manual is created

  10. USGIN ISO metadata profile

    Science.gov (United States)

    Richard, S. M.

    2011-12-01

    The USGIN project has drafted and is using a specification for use of ISO 19115/19/39 metadata, recommendations for simple metadata content, and a proposal for a URI scheme to identify resources using resolvable http URI's(see http://lab.usgin.org/usgin-profiles). The principal target use case is a catalog in which resources can be registered and described by data providers for discovery by users. We are currently using the ESRI Geoportal (Open Source), with configuration files for the USGIN profile. The metadata offered by the catalog must provide sufficient content to guide search engines to locate requested resources, to describe the resource content, provenance, and quality so users can determine if the resource will serve for intended usage, and finally to enable human users and sofware clients to obtain or access the resource. In order to achieve an operational federated catalog system, provisions in the ISO specification must be restricted and usage clarified to reduce the heterogeneity of 'standard' metadata and service implementations such that a single client can search against different catalogs, and the metadata returned by catalogs can be parsed reliably to locate required information. Usage of the complex ISO 19139 XML schema allows for a great deal of structured metadata content, but the heterogenity in approaches to content encoding has hampered development of sophisticated client software that can take advantage of the rich metadata; the lack of such clients in turn reduces motivation for metadata producers to produce content-rich metadata. If the only significant use of the detailed, structured metadata is to format into text for people to read, then the detailed information could be put in free text elements and be just as useful. In order for complex metadata encoding and content to be useful, there must be clear and unambiguous conventions on the encoding that are utilized by the community that wishes to take advantage of advanced metadata

  11. ISO CD 14492

    DEFF Research Database (Denmark)

    Martins, Bo; Kossentini, F.; Arps, R.

    1998-01-01

    This Recommendation | International Standard, informally called JBIG2, defines a coding method for bilevel images, that is, images consisting of a single rectangular bit plane, with each pixel taking on one of just two possible colors. Itis being drafted by the Joint Bi-level Image Experts Group ...... (JBIG), a "Collaborative team" that reports both to ISO/IEC JTC1/SC29/WG1 and to ITU-T/SG8....

  12. Implications of ISO 9000 for personnel dosimetry

    International Nuclear Information System (INIS)

    Yoder, R.C.

    1995-01-01

    Landauer, Inc. has gained approval to provide personnel dosimetry services in several countries. Each experiene reflects the different concerns adopted by national approval agencies. None have adopted ISO 9000 registration as evidence of a suitable quality system of management. Instead, each organization has prepared its own set of requirements with no provisions for recognizing the results of performance tests or audits conducted by other approval organizations. As ISO 9000 has become a communication symbol for commercial organizations dealing with each other, it has not been similarly viewed by radiation regulation bodies. A key reason arises from a tradition to regulate bodies. A key reason arises from a tradition to regulate, not promote, international trade, not encourage innovation, nor foster economic competition. A second reason is the inability to separate the technical requirements from quality assurance. ISO 9000 may become useful once the national technical organizations learn to trust those of other countries

  13. IMPLEMENTASI SISTEM MANAJEMEN MUTU BERBASIS ISO 9001:2000 PADA SEKOLAH MENENGAH KEJURUAN

    Directory of Open Access Journals (Sweden)

    Mardi Wiyono

    2012-09-01

    Full Text Available Abstract: The implementation of ISO 9001:2000 quality management system in vocational school. The needs of quality products and services is largerly expanded in various organizations including education. Recently, the vocational schools also realize how important the quality product and service is. For achieving the quality product or service, some organizations implement the concept of ISO 9001:2000 quality management system. In 2006/2007 it is reported that there are some vocational schools have been certified with ISO 9001:2000. ISO 9001 is a serial document consists of Quality Management System Standard which has been refised from its previous standard. ISO 9001:2000 gives a number of prerequisites for organizations having business initialized by design and development, production, installations, and services. The vocational schools which have been certified with ISO 9001:2000, have to be re-accredited after three years of implementation.

  14. 21 CFR 184.1165 - n-Butane and iso-butane.

    Science.gov (United States)

    2010-04-01

    ... FOR HUMAN CONSUMPTION (CONTINUED) DIRECT FOOD SUBSTANCES AFFIRMED AS GENERALLY RECOGNIZED AS SAFE Listing of Specific Substances Affirmed as GRAS § 184.1165 n-Butane and iso-butane. (a) n-Butane and iso..., odorless, flammable gases at normal temperatures and pressures. They are easily liquefied under pressure at...

  15. Juhtimissüsteemide selgroog. Lean ning ISO - terviklahendused tootmise haldamiseks / Anton Ovsjankin

    Index Scriptorium Estoniae

    Ovsjankin, Anton

    2011-01-01

    Kasvanud on juurutatavate Lean ja ISO süsteemide arv, kuid on kasvanud ka nende juurutamise ja arendamisega seotud ebaõnnestumiste arv. Põhjustest, miks jäävad paljud Leani ja ISO juurutanud ettevõtted ilma lubatud tulemusteta. Leani ja ISO haldamiseks vajalikest teguritest

  16. ISO 14000: Review and guidelines for the photovoltaic industry

    Energy Technology Data Exchange (ETDEWEB)

    DePhillips, M.P.

    1997-08-01

    The International Organization for Standardization (ISO) has released and is in the process of ratifying a new set of environmental management system standards, ISO 14000. These voluntary international standards will have a significant impact on how companies throughout the international community manage their environmental programs. Initially this impact will result in increased international trade opportunities due to the anticipated customer requirement for suppliers to demonstrate certification. Other potential impacts will benefit both companies engaged in international commerce and companies with a domestic focus. These would include installing a cohesive system to manage environmental matters, participation within a new regulatory paradigm, and adhering to a potentially new set of legal standards. The wide range of potential environmental, commercial, legal and regulatory benefits offered by ISO 14000 offer most companies significant reason to explore the possibilities of implementing an environmental management system. Organizations will be able to anticipate and meet growing environmental expectations and to ensure ongoing compliance with national and international requirements as well as satisfy the growing demands of customers, stakeholders and the interested public. As an emerging industry with significant international ties, the photovoltaic (PV) community will be effected from these standards if they do become globally adopted. In fact some major players in the PV industry have recently received certification to ISO 9000. This again demonstrates a trend within the industry to move toward a uniform system approach to management. This paper will expose interested parties within the PV industry to the details of ISO 14000 and will assist decision makers assess the various possibilities for implementation certification of ISO 14000 for an individual facility.

  17. Validation of powder X-ray diffraction following EN ISO/IEC 17025.

    Science.gov (United States)

    Eckardt, Regina; Krupicka, Erik; Hofmeister, Wolfgang

    2012-05-01

    Powder X-ray diffraction (PXRD) is used widely in forensic science laboratories with the main focus of qualitative phase identification. Little is found in literature referring to the topic of validation of PXRD in the field of forensic sciences. According to EN ISO/IEC 17025, the method has to be tested for several parameters. Trueness, specificity, and selectivity of PXRD were tested using certified reference materials or a combination thereof. All three tested parameters showed the secure performance of the method. Sample preparation errors were simulated to evaluate the robustness of the method. These errors were either easily detected by the operator or nonsignificant for phase identification. In case of the detection limit, a statistical evaluation of the signal-to-noise ratio showed that a peak criterion of three sigma is inadequate and recommendations for a more realistic peak criterion are given. Finally, the results of an international proficiency test showed the secure performance of PXRD. © 2012 American Academy of Forensic Sciences.

  18. ISO 9000. Guidelines to increased costs and reduced product quality

    International Nuclear Information System (INIS)

    Reedy, R.F.

    1994-01-01

    Many US companies are considering being registered to the provisions of ISO 9000, International Standards for Quality Management. One important problem with the document is that ISO 9000 is not focused on control of product quality. The quality assurance rules established in ISO 9000 have been used in the US for more than 25 years with disastrous financial consequences and little, if any, improvement in quality and safety. These rules are so reliant on documentation and strict compliance that ensuring products comply with specifications has become a secondary issues. That is not what was intended, but it is the result. ISO 9000 program can work effectively only when the top executive responsible for engineering or production takes full responsibility for interpretation and implementation of the quality assurance program. 3 refs., 1 tab

  19. 75 FR 51996 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Science.gov (United States)

    2010-08-24

    ... Midwest ISO Meetings August 16, 2010. The Federal Energy Regulatory Commission hereby gives notice that members of the Commission and Commission staff may attend the following Midwest ISO-related meetings...., St. Paul, MN) [cir] September 15 [cir] October 20 [cir] November 17 [cir] December 1 Midwest ISO...

  20. ISO celebrates its prolonged life with a video of Jupiter

    Science.gov (United States)

    1997-07-01

    This is excellent news for astronomers and especially for the multinational teams, with leaders in France, Germany, the Netherlands and the United Kingdom, who spent many years devising the four instruments served by ISO's telescope. The camera ISOCAM, the photometer ISOPHOT, the Short Wavelength Spectrometer and the Long Wavelength Spectrometer span between them an unprecedented range of infrared wavelengths from 2 to 200 microns. The atmosphere of Jupiter is one of the cool and cloudy places attracting ISO's attention, and ESA today releases a video of unprecedented images of Jupiter. The planet changes its appearance drastically as the camera ISOCAM scans a range of 90 different infrared wavelengths. Picture by picture, ISOCAM picks out different features of the atmosphere's composition and behaviour. These and other results from ISO will enable scientists to sharpen their ideas about how Jupiter's weather works. "ISO is giving us a new impression of the giant planets of the Solar System," comments Roger Bonnet, ESA's director of science. "Not just Jupiter, but Saturn, Uranus and Neptune too. By observing the planets across its very wide range of infrared wavelengths, ISO can see features overlooked even by spacecraft visiting the planets. The remarkable movie of Jupiter released today represents only a few per cent of ISO's wavelength range, yet every image tells its own story." More information about the Jupiter video appears later in this Information Note. How ISO's cold telescope beat the calendar The need to keep ISO's telescope and instruments chilled to a very low temperature sets a limit to their useful operating life. ISO was supplied with more than 2000 litres of superfluid helium to cool it. Slow evaporation maintains key parts of the spacecraft at temperatures close to absolute zero, below minus 271 degrees C. The rate of loss of helium was expected to be about 3 litres a day, but the cryogenic system could not be tested in exactly the conditions

  1. Possibilities of using ISO 1406X standards in the management of greenhouse gas emissions

    International Nuclear Information System (INIS)

    Fabian, G.; Priesol, J.

    2009-01-01

    Aim of this paper is to define and describe using of ISO 1406X standards for organization, which production of greenhouse gas emissions represents an important environmental aspect especially in terms of financial benefits accruing from trading with saved / reduced emissions. Following the main aim of this paper, we have set the following sub-objectives and tasks: - Define and describe the algorithm of implementation of program on greenhouse gas emissions according to the requirements and guidelines of the ISO 1406X in the organization; - Create a model of comprehensive management of greenhouse gas emissions standards as described.

  2. THE TRANSITIONAL CHANGE ON THE IMPLEMENTATION OF ISO 14001:2015 IN COPPER ORE MILL – CASE STUDY

    Directory of Open Access Journals (Sweden)

    Arif Susanto

    2017-09-01

    Full Text Available The transition process of implementation standard for environmental management system (EMS ISO 14001 :2015 lasts for three years, requiring every organization to adopt the latest version by September 2018. The objectives of this research is to describe and analyze the stages done by copper ore mill. This research used concept analysis method, which focused and could be basically defined to examine the basic elements of widely used concept to clarify ISO 14001 :2015 standards characteristics and relations. The result of this research provided a conceptual framework based on the standard of ISO 14001:2015 – EMS : Requirements with Guidance for Use, where this framework consists to steps to design the transition change from EMS ISO 14001 :2004 to its 2015 new version. The description of every step is expected to give understanding and model for organizations that must conduct transition and for the ones that will start implementing the EMS.

  3. Evaluation of a fungal collection as certified reference material producer and as a biological resource center

    Directory of Open Access Journals (Sweden)

    Tatiana Forti

    2016-06-01

    Full Text Available Abstract Considering the absence of standards for culture collections and more specifically for biological resource centers in the world, in addition to the absence of certified biological material in Brazil, this study aimed to evaluate a Fungal Collection from Fiocruz, as a producer of certified reference material and as Biological Resource Center (BRC. For this evaluation, a checklist based on the requirements of ABNT ISO GUIA34:2012 correlated with the ABNT NBR ISO/IEC17025:2005, was designed and applied. Complementing the implementation of the checklist, an internal audit was performed. An evaluation of this Collection as a BRC was also conducted following the requirements of the NIT-DICLA-061, the Brazilian internal standard from Inmetro, based on ABNT NBR ISO/IEC 17025:2005, ABNT ISO GUIA 34:2012 and OECD Best Practice Guidelines for BRCs. This was the first time that the NIT DICLA-061 was applied in a culture collection during an internal audit. The assessments enabled the proposal for the adequacy of this Collection to assure the implementation of the management system for their future accreditation by Inmetro as a certified reference material producer as well as its future accreditation as a Biological Resource Center according to the NIT-DICLA-061.

  4. ISO standardization in nuclear technology

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D [Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia); Cermak, O [Urad pro Normalizaci a Mereni, Prague (Czechoslovakia)

    1984-10-01

    The activity is described of the technical commission ISO/TC 85 which is currently divided into 4 subcommissions (SC) and 24 working groups. SC 1 ''Terminology, definitions, units, abbreviations'' has one working group. The most important document of this SC is ISO 921-1972 (Dictionary of nuclear technology). SC 2 ''Radiation protection'' has 9 working groups and has processed standards in dosimetry. SC 3 ''Technology of power reactors'' has 6 working groups and its work is related to IAEA activities within the NUSS program. SC 4 ''Technology of nuclear fuels'' has 8 working groups. SC 4 has compiled the basic standards for sealed sources and methods of testing their tightness. The results of the work of this group have been reflected into the standardization work of CMEA. A list is given of published international standards within TC 85.

  5. Pressure-dependent kinetics of initial reactions in iso-octane pyrolysis.

    Science.gov (United States)

    Ning, HongBo; Gong, ChunMing; Li, ZeRong; Li, XiangYuan

    2015-05-07

    This study focuses on the studies of the main pressure-dependent reaction types of iso-octane (iso-C8H18) pyrolysis, including initial C-C bond fission of iso-octane, isomerization, and β-scission reactions of the alkyl radicals produced by the C-C bond fission of iso-octane. For the C-C bond fission of iso-octane, the minimum energy potentials are calculated at the CASPT2(2e,2o)/6-31+G(d,p)//CAS(2e,2o)/6-31+G(d,p) level of theory. For the isomerization and the β-scission reactions of the alkyl radicals, the optimization of the geometries and the vibrational frequencies of the reactants, transition states, and products are performed at the B3LYP/CBSB7 level, and their single point energies are calculated by using the composite CBS-QB3 method. Variable reaction coordinate transition state theory (VRC-TST) is used for the high-pressure limit rate constant calculation and Rice-Ramsperger-Kassel-Marcus/master equation (RRKM/ME) is used to calculate the pressure-dependent rate constants of these channels with pressure varying from 0.01-100 atm. The rate constants obtained in this work are in good agreement with those available from literatures. We have updated the rate constants and thermodynamic parameters for species involved in these reactions into a current chemical kinetic mechanism and also have improved the concentration profiles of main products such as C3H6 and C4H6 in the shock tube pyrolysis of iso-octane. The results of this study provide insight into the pyrolysis of iso-octane and will be helpful in the future development of branched paraffin kinetic mechanisms.

  6. Certified reference materials for the determination of mineral oil hydrocarbons in water, soil and waste

    Energy Technology Data Exchange (ETDEWEB)

    Koch, M.; Liebich, A.; Win, T.; Nehls, I.

    2005-07-01

    The international research project HYCREF, funded by the European Commission in the 5{sup th} Framework programme, aimed to develop methods to prepare homogeneous and stable water-, soil- and waste reference materials contaminated with mineral oil hydrocarbons and to test certify the mineral oil content by gas chromatographic methods. As mineral oil products are important sources for environmental contaminations a high need exists for certified reference materials for their determination using the new gas chromatographic methods (soil: ISO/FDIS 16703, waste: ENpr 14039, water: ISO 9377-2). The experimental conditions and results for preparation and characterisation of a total of nine reference materials (3 water, 3 soil- and 3 waste materials) are described and discussed. Target values for the reference materials were defined at the beginning of the project in order to have clear quality criteria, which could be compared with the achieved results at the end of the project. These target specifications were related to the maximum uncertainty from test certification exercises (<5% for soil/waste and <10% for water), the maximum inhomogeneity between bottles (<3%) and minimum requirements for stability (>5 years for soil/waste and >2 years for water). The feasibility studies showed that solid materials (soil, waste) could be prepared sufficiently homogeneous and stable. The test certified values of the 6 solid materials comprise a wide range of mineral oil content from about 200-9000 mg/kg with expanded uncertainties between 5.7-13.1% using a coverage factor k (k=2). The development of new water reference materials - the so-called ''spiking pills'' for an offshore- and a land-based discharge water represents one of the most innovative aspects of the project. The spiking pill technology facilitates the application and storage and improves the material stability compared with aqueous materials. Additional to the preparation and test certification of

  7. Energy management systems in the practice. ISO 50001. A guideline for companies and institutions; Energiemanagementsysteme in der Praxis. ISO 50001. Leitfaden fuer Unternehmen und Organisationen

    Energy Technology Data Exchange (ETDEWEB)

    Kohlenborn, Walter; Kabisch, Sibylle; Klein, Johanna; Richter, Ina; Schuermann, Silas

    2012-06-15

    The guideline under consideration is an updated version of the guideline to the regulation EN 16001 and amended to ISO 50001. This contribution supports institutes in the implementation of an energy management system according to ISO 50001. The differences and commonalities to the European environment management system EMAS as well as to the regulation ISO 14001 are described. EMAS certified companies fulfil regularly all conditions of an energy management system. A practised energy management system is an excellent platform for the implementation of EMAS.

  8. 76 FR 4104 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Science.gov (United States)

    2011-01-24

    ... Midwest ISO Meetings January 13, 2011. The Federal Energy Regulatory Commission hereby gives notice that members of the Commission and Commission staff may attend the following Midwest ISO-related meetings...] September 14 [cir] October 19 [cir] November 16 [cir] December 6 Midwest ISO Informational Forum (3 p.m.-5 p...

  9. 75 FR 3228 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Science.gov (United States)

    2010-01-20

    ... Midwest ISO Meetings January 12, 2010. The Federal Energy Regulatory Commission hereby gives notice that members of the Commission and Commission staff may attend the following Midwest ISO-related meetings...] November 17 [cir] December 1 Midwest ISO Informational Forum (3 p.m.-5 p.m., ET) [cir] January 19 [cir...

  10. KSC Center Director Bridges accepts an ISO 9001 certificate from DNV

    Science.gov (United States)

    1998-01-01

    Center Director Roy Bridges displays the ISO 9001 certificate he was awarded by Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. Dalton Lyon of DNV made the presentation, which included a 2000th ISO Certificate Plaque. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world-class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification.

  11. Ignition delay time measurements of primary reference fuel blends

    KAUST Repository

    Alabbad, Mohammed

    2017-02-07

    Ignition delay times of four different primary reference fuels (PRF), mixtures of n-heptane and iso-octane, were measured behind reflected shock waves in a high-pressure shock tube facility. The PRFs were formulated to match the RON of two high-octane gasolines (RON 95 and 91) and two prospective low-octane naphtha fuels (RON 80 and 70). Experiments were carried out over a wide range of temperatures (700–1200K), pressures (10, 20, and 40bar) and equivalence ratios (0.5 and 1). Kinetic modeling predictions from four chemical kinetic mechanisms are compared with the experimental data. Ignition delay correlations are developed to reproduce the measured ignition delay times. Brute force sensitivity analyses are carried out to identify reactions that affect ignition delay times at specific temperature, pressure and equivalence ratio. The large experimental data set provided in the current work will serve as a benchmark for the validation of chemical kinetic mechanisms of primary reference fuel blends.

  12. Ignition delay time measurements of primary reference fuel blends

    KAUST Repository

    Alabbad, Mohammed; Javed, Tamour; Khaled, Fathi; Badra, Jihad; Farooq, Aamir

    2017-01-01

    Ignition delay times of four different primary reference fuels (PRF), mixtures of n-heptane and iso-octane, were measured behind reflected shock waves in a high-pressure shock tube facility. The PRFs were formulated to match the RON of two high-octane gasolines (RON 95 and 91) and two prospective low-octane naphtha fuels (RON 80 and 70). Experiments were carried out over a wide range of temperatures (700–1200K), pressures (10, 20, and 40bar) and equivalence ratios (0.5 and 1). Kinetic modeling predictions from four chemical kinetic mechanisms are compared with the experimental data. Ignition delay correlations are developed to reproduce the measured ignition delay times. Brute force sensitivity analyses are carried out to identify reactions that affect ignition delay times at specific temperature, pressure and equivalence ratio. The large experimental data set provided in the current work will serve as a benchmark for the validation of chemical kinetic mechanisms of primary reference fuel blends.

  13. Competence Requirements of ISO/IEC Standards for Information Security Professionals

    Directory of Open Access Journals (Sweden)

    Natalia G. Miloslavskaya

    2017-11-01

    Full Text Available The rapid progress in the filed of information security (IS puts one in a need of periodic revision of professional competencies (formulated in the federal state educational standards –FSESs and working functions (formulated in the professional standards – PSs. Under these conditions, a timely reaction to everything new that emerges or will appear in modern regulatory documents (primarily in standards is extremely important. We make a forecast for the content of the ISO/IEC 27021 and ISO/IEC 19896 standards drafted by the International Organization for Standardization (ISO, which should contain the requirements for the competencies of IS management system professionals and the competence of IS testers and evaluators. Our forecast takes into account the requirements of the ISO/IEC 27000 standard group and the recommendations of the European e-Competence Framework e-CF 3.0.

  14. Migración de un SGSI basado en ISO/IEC 27001:2005 a la versión ISO/IEC 27001:2013

    OpenAIRE

    Espol; Rendón Freire, María José

    2015-01-01

    Este proyecto tiene como objetivo identificar los cambios en los requisitos de la norma ISO/IEC 27001:2013 respecto a la versión 2005, para lograr la actualización de un sistema de gestión de seguridad de la información basado en ISO/IEC 27001:2005 acorde a lo establecido en el nuevo estándar. Guayaquil Magíster en Seguridad Informática Aplicada

  15. Sifting through the ISO 9000 maze

    International Nuclear Information System (INIS)

    Abraham, K.S.

    1993-01-01

    Various forces in the global upstream market are more frequently pressuring equipment and services firms to be certified according to the latest international standards in order to do business. However, understanding and completing the registration process can appear confusing and intimidating at first glance. This paper reviews the ISO's 9000 series of generic standards that provide quality assurance requirements and management guidance. It describes its applicability to the oil and gas industry which often found itself cut out of international markets because they were not recognized as registered ISO participants. It then describes the registration process, evaluation process, and time tables involved. It also describes the difference performance standards of the 9000 series

  16. IMPLEMENTING AN ISO 10001-BASED PROMISE IN INPATIENTS CARE

    Directory of Open Access Journals (Sweden)

    Mohammad Ashiqur Rahman Khan

    2013-09-01

    Full Text Available This paper presents the implementation of a Customer Satisfaction Promise (CSP that requires nurses to introduce themselves and explain the care plan to the patients of a hospital unit in Canada. The CSP implementation, maintenance and improvement activities were based on ISO 10001:2007. Qualitative and quantitative performance data were collected from nurses, the unit manager and patients, and improvement suggestions were made. During the implementation, nurses introduced themselves 95% of the time and explained the care plan 86% of the time. When interviewed, some nurses stated that the CSP was a good reinforcement of a practice already expected of them, which made patients happy, satisfied and more comfortable. Data from a small sample of patients was not adequate in clearly indicating the CSP's performance or improvement, but was useful in validating the survey and the feedback form. To our knowledge, applications of ISO 10001:2007 in health care have not been studied. Furthermore, this paper may be the first example of the integrated use of ISO 10001 and ISO 10002 in health care.

  17. Preparation and characterization of the fish reference material

    International Nuclear Information System (INIS)

    Ulrich, Joao Cristiano

    2011-01-01

    The certified reference materials (CRMs) play an important role in obtaining measurement results traceable to the International System of Units, through an unbroken chain of comparisons. Thus, the demand for new certified reference materials (CRMs) increases every day in all areas of knowledge. The availability of reference materials, mainly in Brazil is still incipient, given that the demand far exceeds the available variety of these materials. The amount of certified reference materials available in the country is insufficient to meet the need of the scientific community and demands for development of new methodologies. Among the many areas in need of reference materials, we highlight the importance for the food trade balance for these products within the country. The certification of food products, intended both for export and for domestic consumption, requires analysis methods that provide precise and accurate results to ensure product quality. This paper describes the preparation and certification of a reference material in the fish matrix in mercury and methylmercury. The study brings together since the stage of material selection, preparation, development of homogeneity and stability studies and characterization. The certification was performed by means of measurements using two analytical techniques, flow injection analysis - cold vapor atomic absorption spectrometry (FIA-CV-AAS) and isotope dilution applied to mass spectrometry (IDMS), which is a primary method. In this work the standards of the ISO 30 (ABNT 30-34) and ISO Guide 35 was used as the basis for the preparation and characterization of the material. For the calculation of uncertainties was used the GUM and Eurachem guide. As a result, was produced and certified a lot of material in relation to the concentration of mercury (Hg = 0.271 ± 0.057 mg g -1 ) and methylmercury (MeHg = 0.245 ± 0.038 mg g -1 ), and informational values of lead and arsenic. (author)

  18. Towards better GHG emissions savings with use of ISO GHG standards

    International Nuclear Information System (INIS)

    Chan Kook Weng

    2010-01-01

    The 15th Conference of Parties (COP 15) at Copenhagen, Denmark in December 2009 highlighted the need to combat climate change by facing the challenge of committing to reducing our emissions at all three levels with locally appropriate mitigation actions (LAMAs) at the local level to be linked to the nationally appropriate mitigation actions (NAMAs) and then contribute onwards to globally appropriate mitigation actions (GAMAs). The aim is to find solutions for both adaptation and mitigation by ensuring sufficient means are made available to support such efforts. This is because the world in entering a new phase that will be characterised by green growth in business. Thus be it agriculture that uses local knowledge of specific crop and livestock varieties to help in secure food supply, bio-energy, transport, industries, there must be policies to understand ecosystem-based to link people, biodiversity, energy, water and carbon so as to be more resilient and adaptable to the need for a low carbon economy in todays society.Climate change therefore affects organisations in many areas and they include legal compliance, carbon market, corporate social responsibility and sustainable development. Promoting sustainability requires making efficient use of energy, water and natural resources, decrease in waste load through recycling and streamlining the processes leading to everything that decreases their CO 2 and water footprints. Currently there are many GHG schemes and programmes and the issues centres around compatibility, costs and most importantly credibility. Achieving real GHG emissions reduction requires controlled and verified emissions reductions and quantification that are sound and verifiable. Thanks to the development of the ISO suite of standards on GHG and related matters, the use of these harmonised standards has given the assurance that a tonne of carbon is a tonne of carbon be it in Malaysia, Mali or Mongolia.The use of these standards like ISO 14064 Part 1

  19. Evaluating Education Quality in Terms of ISO9000 Standards

    Science.gov (United States)

    Fengchun, Cheng; Vogel, Linda R.; Zhaoyu, Zheng

    2014-01-01

    While nations measure the quality of educational systems by different standards, many nations, such as China, have adopted the ISO9000 quality standards to assess the quality of schools. This article explores the various elements of the the ISO9000 standards and how each element relates to the various groups that are consumers or stakeholders in…

  20. Manufacturing Bms/Iso System Review

    Science.gov (United States)

    Gomez, Yazmin

    2004-01-01

    The Quality Management System (QMS) is one that recognizes the need to continuously change and improve an organization s products and services as determined by system feedback, and corresponding management decisions. The purpose of a Quality Management System is to minimize quality variability of an organization's products and services. The optimal Quality Management System balances the need for an organization to maintain flexibility in the products and services it provides with the need for providing the appropriate level of discipline and control over the processes used to provide them. The goal of a Quality Management System is to ensure the quality of the products and services while consistently (through minimizing quality variability) meeting or exceeding customer expectations. The GRC Business Management System (BMS) is the foundation of the Center's ISO 9001:2000 registered quality system. ISO 9001 is a quality system model developed by the International Organization for Standardization. BMS supports and promote the Glenn Research Center Quality Policy and wants to ensure the customer satisfaction while also meeting quality standards. My assignment during this summer is to examine the manufacturing processes used to develop research hardware, which in most cases are one of a kind hardware, made with non conventional equipment and materials. During this process of observation I will make a determination, based on my observations of the hardware development processes the best way to meet customer requirements and at the same time achieve the GRC quality standards. The purpose of my task is to review the manufacturing processes identifying opportunities in which to optimize the efficiency of the processes and establish a plan for implementation and continuous improvement.

  1. Delusions of reference: a new theoretical model.

    Science.gov (United States)

    Startup, Mike; Bucci, Sandra; Langdon, Robyn

    2009-03-01

    Although delusions of reference are one of the most common psychotic symptoms, they have been the focus of little research, possibly because they have been considered to be integral to persecutory delusions. Evidence has now emerged that there are two kinds of delusion of reference. One of these, referential delusions of communication, which involves beliefs that others are communicating in subtle, nonverbal ways, is the focus of this paper. We present a new model designed to account for the four crucial aspects of the phenomenology of these delusions: (1) that neutral stimuli are experienced as having personal significance; (2) that the neutral stimuli are experienced as communicating a message nonverbally; (3) that the content of the message concerns the self; (4) that the experience of a self-referent communication is believed rather than being dismissed as implausible. We used PsycINFO and Scopus, using the term "delusion* of reference", to search for publications with a bearing on our model. The amount of research we found that was designed to test aspects of this model is small but other published research appears to provide some support for its various steps. Much of this research was not explicitly intended to provide an account of delusions of reference but its relevance nevertheless seems clear. There is preliminary support for the plausibility of our model but much additional research is needed. We conclude by summarising what we consider to be the main desiderata.

  2. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems: the importance of preload in ISO 12189.

    Science.gov (United States)

    La Barbera, Luigi; Ottardi, Claudia; Villa, Tomaso

    2015-10-01

    Preclinical evaluation of the mechanical reliability of fixation devices is a mandatory activity before their introduction into market. There are two standardized protocols for preclinical testing of spinal implants. The American Society for Testing Materials (ASTM) recommends the F1717 standard, which describes a vertebrectomy condition that is relatively simple to implement, whereas the International Organization for Standardization (ISO) suggests the 12189 standard, which describes a more complex physiological anterior support-based setup. Moreover, ASTM F1717 is nowadays well established, whereas ISO 12189 has received little attention: A few studies tried to accurately describe the ISO experimental procedure through numeric models, but these studies totally neglect the recommended precompression step. This study aimed to build up a reliable, validated numeric model capable of describing the stress on the rods of a spinal fixator assembled according to ISO 12189 standard procedure. Such a model would more adequately represent the in vitro testing condition. This study used finite element (FE) simulations and experimental validation testing. An FE model of the ISO setup was built to calculate the stress on the rods. Simulation was validated by comparison with experimental strain gauges measurements. The same fixator has been previously virtually mounted in an L2-L4 FE model of the lumbar spine, and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between the FE predictions and experimental measurements is in good agreement, thus confirming the suitability of the FE method to evaluate the stresses in the device. The initial precompression induces a significant extension of the assembled construct. As the applied load increases, the initial extension is gradually compensated, so that at peak load the rods are bent in flexion: The final stress value predicted is thus reduced to about 50%, if

  3. Establishing an ISO 10001-based promise in inpatients care.

    Science.gov (United States)

    Khan, Mohammad Ashiqur Rahman; Karapetrovic, Stanislav

    2015-01-01

    The purpose of this paper is to explore ISO 10001:2007 in planning, designing and developing a customer satisfaction promise (CSP) intended for inpatients care. Through meetings and interviews with research participants, who included a program manager, unit managers and registered nurses, information about potential promises and their implementation was obtained and analyzed. A number of promises were drafted and one was finally selected to be developed as a CSP. Applying the standard required adaptation and novel interpretation. Additionally, ISO 10002:2004 (Clause 7) was used to design the feedback handling activities. A promise initially chosen for development turned out to be difficult to implement, experience that helped in selecting and developing the final promise. Research participants found the ISO 10001-based method useful and comprehensible. This paper presents a specific health care example of how to adapt a standard's guideline in establishing customer promises. The authors show how a promise can be used in alleviating an existing issue (i.e. communication between carers and patients). The learning can be beneficial in various health care settings. To the knowledge, this paper shows the first example of applying ISO 10001:2007 in a health care case. A few activities suggested by the standard are further detailed, and a new activity is introduced. The integrated use of ISO 10001:2007 and 10002:2004 is presented and how one can be "augmented" by the other is demonstrated.

  4. Correspondence of ISO 9001:2008 with IAEA GS-R-3

    International Nuclear Information System (INIS)

    Kibrit, Eduardo

    2009-01-01

    This article identifies, characterises and analyses International Organisation for Standardisation (ISO) and International Atomic Energy Agency (IAEA) normative requirements for the development and implementation of quality management systems in nuclear organisations. The structures of the applicable standards, ISO 9001:2008 and IAEA GS-R-3, are characterised. The differences and similarities of objective, focus, scope, level of application, structure, vocabulary, management system, management responsibility, resource management, process implementation, measurement, assessment and improvement verified in the applicable standards are deeply reviewed. A correspondence of the applicable standards' requirements is presented topic by topic. A correlation of the applicable standards' requirements is made, showing IAEA GS-R-3 topics that have no correlation with ISO 9001:2008 and ISO 9001:2008 topics that have no correlation with IAEA GS-R-3. Conclusive remarks advise the pros and cons of using one of the applicable standards or the other. (author)

  5. The CMMI Product Suite and International Standards

    Science.gov (United States)

    2006-07-01

    standards: “2.3 Reference Documents 2.3.1 Applicable ISO /IEC documents, including ISO /IEC 12207 and ISO /IEC 15504.” “3.1 Development User Requirements...related international standards such as ISO 9001:2000, 12207 , 15288 © 2006 by Carnegie Mellon University Page 12 Key Supplements Needed...the Measurement Framework in ISO /IEC 15504; and • the Process Reference Model included in ISO /IEC 12207 . A possible approach has been developed for

  6. Development of tire road noise chassis-dynamometer simulator. Effect of ISO surface replica model pad on tire road noise; Shisakushita tire romen soon shiken`yo jissha daijo simulator ni tsuite. ISO romen mogi pad wo sochakushita koka ni kansuru kisoteki kento

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T; Murakami, T; Ogata, S; Sakamoto, I [Traffic Safety and Nuisance Research Inst., Tokyo (Japan)

    1997-10-01

    As a new test facility to clarify noise reduction method of tire road noise, Tire Road Noise Chassis-Dynamometer Simulator was developed. ISO surface replica pads made by copying the texture of ISO surface were attached on the roller surface of this system to simulate tire road noise. This paper described the specifications and characteristics of this system, and the effects of ISO surface replica pads on tire noise measurement by comparing the sound intensity in horizontal plane of tire noise measured in this system with that measured in a single drum tester with safety walk surface. 4 refs., 10 figs., 1 tab.

  7. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    Science.gov (United States)

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  8. ISO 9000 IMPLEMENTATION AND PERCEIVED ORGANISATIONAL OUTCOME: THE CASE OF A SERVICE ORGANISATION

    Directory of Open Access Journals (Sweden)

    Jasni Abdul Latif

    2003-01-01

    Full Text Available The study examines the relationship between the perceptions of the employees about ISO 9000 implementation and perceived organisational outcomes. A conceptual framework linking the level of employee influence and involvement, their perception of ISO 9000 and the perceived impact on their work and the organisational outcomes is posited. Data was collected from a random sample of 64 employees of a service organisation. Contrary to expectations, the work impact of ISO 9000 was not correlated with the efficiency and market outcomes of ISO 9000 certification but the employee involvement, influence and perception of ISO 9000 were. The conceptualization of the influence path of ISO 9000 implementation on the organisational outcomes may require rethinking as perception may have a direct effect on the outcomes without the mediation of the impact on work. In short, employees may report benefits or positive outcomes even though no change is reported in their work.

  9. ISO 14000 and the nuclear licensing

    International Nuclear Information System (INIS)

    Martins, Nadia Soido Falcao

    1999-01-01

    As concern grows for maintaining and improving the quality of the environment and protecting human health, all the world is turning its attention to the potential environmental in pact of their industrial activities. One of the most important contribution in that way is the International Standard ISO 14000 series. In the utilization of nuclear energy, right from the inception, the safety of personnel, environment and the population has been the basic consideration. Over the years well established licenses criteria have been proposed to limit and control the environmental impact of the plant operation and emergencies situation. In this paper are discussed some specific requirements for implementation of the environmental management system specified by ISO 14000 compared to the environmental requirements for nuclear licensing. (author)

  10. BiBTeX styl pro ČSN ISO 690 a ČSN ISO 690-2

    OpenAIRE

    Pyšný, Radek

    2009-01-01

    Tato práce popisuje průběh vytváření bibliografického stylu pro nástroj BibTeX, pomocí něhož lze v LaTeXu sázet bibliografické citace v souladu s normou ČSN ISO 690. V úvodu práce je proveden rozbor ČSN ISO 690. Následuje popis spolupráce mezi systémem LaTeX a nástrojem BibTeX. Podstatná část práce je věnována popisu struktury souborů, které BibTeX potřebuje pro svou funkci, tj. bibliografická databáze a bibliografický styl. Závěr této práce je věnovaný popisu vlastností vytvořeného bibliogra...

  11. An approach for the semantic interoperability of ISO EN 13606 and OpenEHR archetypes.

    Science.gov (United States)

    Martínez-Costa, Catalina; Menárguez-Tortosa, Marcos; Fernández-Breis, Jesualdo Tomás

    2010-10-01

    The communication between health information systems of hospitals and primary care organizations is currently an important challenge to improve the quality of clinical practice and patient safety. However, clinical information is usually distributed among several independent systems that may be syntactically or semantically incompatible. This fact prevents healthcare professionals from accessing clinical information of patients in an understandable and normalized way. In this work, we address the semantic interoperability of two EHR standards: OpenEHR and ISO EN 13606. Both standards follow the dual model approach which distinguishes information and knowledge, this being represented through archetypes. The solution presented here is capable of transforming OpenEHR archetypes into ISO EN 13606 and vice versa by combining Semantic Web and Model-driven Engineering technologies. The resulting software implementation has been tested using publicly available collections of archetypes for both standards.

  12. A Reference Model for Virtual Machine Launching Overhead

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Hao; Ren, Shangping; Garzoglio, Gabriele; Timm, Steven; Bernabeu, Gerard; Chadwick, Keith; Noh, Seo-Young

    2016-07-01

    Cloud bursting is one of the key research topics in the cloud computing communities. A well designed cloud bursting module enables private clouds to automatically launch virtual machines (VMs) to public clouds when more resources are needed. One of the main challenges in developing a cloud bursting module is to decide when and where to launch a VM so that all resources are most effectively and efficiently utilized and the system performance is optimized. However, based on system operational data obtained from FermiCloud, a private cloud developed by the Fermi National Accelerator Laboratory for scientific workflows, the VM launching overhead is not a constant. It varies with physical resource utilization, such as CPU and I/O device utilizations, at the time when a VM is launched. Hence, to make judicious decisions as to when and where a VM should be launched, a VM launching overhead reference model is needed. In this paper, we first develop a VM launching overhead reference model based on operational data we have obtained on FermiCloud. Second, we apply the developed reference model on FermiCloud and compare calculated VM launching overhead values based on the model with measured overhead values on FermiCloud. Our empirical results on FermiCloud indicate that the developed reference model is accurate. We believe, with the guidance of the developed reference model, efficient resource allocation algorithms can be developed for cloud bursting process to minimize the operational cost and resource waste.

  13. Reinterpreting the best biomarker of oxidative stress: The 8-iso-PGF(2α)/PGF(2α) ratio distinguishes chemical from enzymatic lipid peroxidation.

    Science.gov (United States)

    van 't Erve, Thomas J; Lih, Fred B; Kadiiska, Maria B; Deterding, Leesa J; Eling, Thomas E; Mason, Ronald P

    2015-06-01

    The biomarker 8-iso-prostaglandin F2α (8-iso-PGF2α) is regarded as the gold standard for detection of excessive chemical lipid peroxidation in humans. However, biosynthesis of 8-iso-PGF2α via enzymatic lipid peroxidation by prostaglandin-endoperoxide synthases (PGHSs), which are significantly induced in inflammation, could lead to incorrect biomarker interpretation. To resolve the ambiguity with this biomarker, the ratio of 8-iso-PGF2α to prostaglandin F2α (PGF2α) is established as a quantitative measure to distinguish enzymatic from chemical lipid peroxidation in vitro, in animal models, and in humans. Using this method, we find that chemical lipid peroxidation contributes only 3% to the total 8-iso-PGF2α in the plasma of rats. In contrast, the 8-iso-PGF2α levels in plasma of human males are generated >99% by chemical lipid peroxidation. This establishes the potential for an alternate pathway of biomarker synthesis, and draws into question the source of increases in 8-iso-PGF2α seen in many human diseases. In conclusion, increases in 8-iso-PGF2α do not necessarily reflect increases in oxidative stress; therefore, past studies using 8-iso-PGF2α as a marker of oxidative stress may have been misinterpreted. The 8-iso-PGF2α/PGF2α ratio can be used to distinguish biomarker synthesis pathways and thus confirm the potential change in oxidative stress in the myriad of disease and chemical exposures known to induce 8-iso-PGF2α. Published by Elsevier Inc.

  14. Framework for establishing records control in hospitals as an ISO 9001 requirement.

    Science.gov (United States)

    Al-Qatawneh, Lina

    2017-02-13

    Purpose The purpose of this paper is to present the process followed to control records in a Jordanian private community hospital as an ISO 9001:2008 standard requirement. Design/methodology/approach Under the hospital quality council's supervision, the quality management and development office staff were responsible for designing, planning and implementing the quality management system (QMS) using the ISO 9001:2008 standard. A policy for records control was established. An action plan for establishing the records control was developed and implemented. On completion, a coding system for records was specified to be used by hospital staff. Finally, an internal audit was performed to verify conformity to the ISO 9001:2008 standard requirements. Findings Successful certification by a neutral body ascertained that the hospital's QMS conformed to the ISO 9001:2008 requirements. A framework was developed that describes the records controlling process, which can be used by staff in any healthcare organization wanting to achieve ISO 9001:2008 accreditation. Originality/value Given the increased interest among healthcare organizations to achieve the ISO 9001 certification, the proposed framework for establishing records control is developed and is expected to be a valuable management tool to improve and sustain healthcare quality.

  15. Establishing a Business Process Reference Model for Universities

    KAUST Repository

    Svensson, Carsten

    2012-09-01

    Modern universities are by any standard complex organizations that, from an IT perspective, present a number of unique challenges. This paper will propose establishing a business process reference framework. The benefit to the users would be a better understanding of the system landscape, business process enablement, collection of performance data and systematic reuse of existing community experience and knowledge. For these reasons reference models such as the SCOR (Supply Chain Operations Reference), DCOR (Design Chain Operations Reference) and ITIL (Information Technology Infrastructure Library) have gained popularity among organizations in both the private and public sectors. We speculate that this success can be replicated in a university setting. Furthermore the paper will outline how the research group suggests moving ahead with the research which will lead to a reference model.

  16. Arranging ISO 13606 archetypes into a knowledge base using UML connectors.

    Science.gov (United States)

    Kopanitsa, Georgy

    2014-01-01

    To enable the efficient reuse of standard based medical data we propose to develop a higher-level information model that will complement the archetype model of ISO 13606. This model will make use of the relationships that are specified in UML to connect medical archetypes into a knowledge base within a repository. UML connectors were analysed for their ability to be applied in the implementation of a higher-level model that will establish relationships between archetypes. An information model was developed using XML Schema notation. The model allows linking different archetypes of one repository into a knowledge base. Presently it supports several relationships and will be advanced in future.

  17. Analysis of ISO 26262 Compliant Techniques for the Automotive Domain

    NARCIS (Netherlands)

    M. S. Kannan; Y. Dajsuren (Yanjindulam); Y. Luo; I. Barosan

    2015-01-01

    htmlabstractThe ISO 26262 standard denes functional safety for automotive E/E systems. Since the publication of the rst edition of this standard in 2011, many dierent safety techniques complying to the ISO 26262 have been developed. However, it is not clear which parts and (sub-) phases of the

  18. Analysis of ISO 26262 compliant techniques for the automotive domain

    NARCIS (Netherlands)

    S., Manoj Kannan; Dajsuren, Y.; Luo, Y.; Barosan, I.; Antkiewicz, M.; Atlee, J.; Dingel, J.; S, R.

    2015-01-01

    The ISO 26262 standard defines functional safety for automotive E/E systems. Since the publication of the first edition of this standard in 2011, many different safety techniques complying to the ISO 26262 have been developed. However, it is not clear which parts and (sub-) phases of the standard

  19. Diagnóstico da integração dos sistemas de gestão ISO 9001, ISO 14001 e OHSAS 18001

    Directory of Open Access Journals (Sweden)

    Samuel Vinícius Bonato

    2015-09-01

    Full Text Available Este artigo apresenta os resultados de uma pesquisa que teve por finalidade o diagnóstico do nível de integração de sistemas de gestão baseados nas normas ISO 9001, ISO 14001 e OHSAS 18001 em empresas do ramo metal-mecânico. Inicialmente foi descrito o método de diagnóstico e posteriormente realizada a sua aplicação em uma empresa já certificada nas três normas, mas que possui dois sistemas de gestão distintos: o Sistema de Gestão da Qualidade (SGQ baseado na norma ISO 9001 e o Sistema de Gestão de Saúde, Segurança e Meio Ambiente (SSM baseado nas normas ISO 14001 e OHSAS 18001. Entre os principais resultados, destaca-se a aceitação favorável do diagnóstico da integração na empresa estudada. Com a realização do diagnóstico, verificou-se que a organização não atende totalmente a integração de nenhum dos requisitos avaliados. Foram sugeridas oportunidades de melhoria para integração dos requisitos normativos comuns, reduzindo custos e recursos para manutenção do sistema de gestão da empresa.

  20. Discussion on the compilation of document of iso quality management system for radiation sterilization enterprises

    International Nuclear Information System (INIS)

    Li Chunhong; Ha Yiming; Zhou Hongjie; Feng Zhiguo; Wang Feng

    2006-01-01

    According to the character of cooperation of radiation sterilization, and association with request of ISO9001, ISO13485 and ISO11137, compilation of document in quality manual, procedure document and technological document during certification of ISO quality management system of cooperation of radiation sterilization was discussed. (authors)

  1. Interim Report on ISO TC 163 Working Group 3. Annual progress report

    Energy Technology Data Exchange (ETDEWEB)

    Fairey, Philip [Florida Solar Energy Center, Cocoa, FL (United States)

    2009-04-02

    This reports cover the initial year efforts of the International Standards Organization (ISO) to develop international standards for rating the energy performance of buildings. The author of this report is a participant in this effort. This report summarizes the activities of the ISO Working Group charged with development of these standards and makes recommendations to the sponsors for future U.S. involvement in this ISO effort.

  2. Progress report on the management of the NEA ISOE system

    Energy Technology Data Exchange (ETDEWEB)

    Lazo, E. [OECD Nuclear Energy Agency, Issy-les-Moulineaux (France)

    1995-03-01

    The Information System on Occupational Exposure (ISOE) was launched by the Organization for Economic Cooperation and Development (OECD), Nuclear Energy Agency (NEA) on 1 January, 1992, to facilitate the communication of dosimetric and ALARA implementation data among nuclear utilities around the world. After two years of operation the System has become a mature interactive network for transfer of data and experience. Currently, 37 utilities from 12 countries, representing 289 power plants, and 12 national regulatory authorities participate in ISOE. Agreements for cooperation also exist between the NEA and the Commission of the European Communities (CEC), and the Paris Center of the WOrld Association of Nuclear Operators (WANO-PC). In addition, the International Atomic Energy Agency (IAEA) is acting as a co-sponsor of ISOE for the participation of non-NEA member countries. Three Regional Technical Centres, Europe, Asia, and Non-NEA member countries, serve to administer the system. The ISOE Network is comprised of three data bases and a communications network at several levels. The three ISOE data bases include the following types of information: NEA1 - annual plant dosimetric information; NEA2 - plant operational characteristics for dose and dose rate reduction; and NEA3 - job specific ALARA practices and experiences. The ISOE communications network has matured greatly during 1992 and 1993. In addition to having access to the above mentioned data bases, participants may now solicit information on new subjects, through the Technical Centres, from all other participants on a real-time basis. Information Sheets on these studies are produced for distribution to all participants. In addition, Topical Reports on areas of interest are produced, and Topical Meetings are held annually.

  3. Progress report on the management of the NEA ISOE system

    International Nuclear Information System (INIS)

    Lazo, E.

    1995-01-01

    The Information System on Occupational Exposure (ISOE) was launched by the Organization for Economic Cooperation and Development (OECD), Nuclear Energy Agency (NEA) on 1 January, 1992, to facilitate the communication of dosimetric and ALARA implementation data among nuclear utilities around the world. After two years of operation the System has become a mature interactive network for transfer of data and experience. Currently, 37 utilities from 12 countries, representing 289 power plants, and 12 national regulatory authorities participate in ISOE. Agreements for cooperation also exist between the NEA and the Commission of the European Communities (CEC), and the Paris Center of the WOrld Association of Nuclear Operators (WANO-PC). In addition, the International Atomic Energy Agency (IAEA) is acting as a co-sponsor of ISOE for the participation of non-NEA member countries. Three Regional Technical Centres, Europe, Asia, and Non-NEA member countries, serve to administer the system. The ISOE Network is comprised of three data bases and a communications network at several levels. The three ISOE data bases include the following types of information: NEA1 - annual plant dosimetric information; NEA2 - plant operational characteristics for dose and dose rate reduction; and NEA3 - job specific ALARA practices and experiences. The ISOE communications network has matured greatly during 1992 and 1993. In addition to having access to the above mentioned data bases, participants may now solicit information on new subjects, through the Technical Centres, from all other participants on a real-time basis. Information Sheets on these studies are produced for distribution to all participants. In addition, Topical Reports on areas of interest are produced, and Topical Meetings are held annually

  4. ISO standardization in nuclear technology

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D. (Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia)); Cermak, O. (Urad pro Normalizaci a Mereni, Prague (Czechoslovakia))

    1984-10-01

    The activity is described of the technical commission ISO/TC 85 which is currently divided into 4 subcommissions (SC) and 24 working groups. SC 1 ''Terminology, definitions, units, abbreviations'' has one working group. The most important document of this SC is ISO 921-1972 (Dictionary of nuclear technology). SC 2 ''Radiation protection'' has 9 working groups and has processed standards in dosimetry. SC 3 ''Technology of power reactors'' has 6 working groups and its work is related to IAEA activities within the NUSS program. SC 4 ''Technology of nuclear fuels'' has 8 working groups. SC 4 has compiled the basic standards for sealed sources and methods of testing their tightness. The results of the work of this group have been reflected into the standardization work of CMEA. A list is given of published international standards within TC 85.

  5. Evaluation of a fungal collection as certified reference material producer and as a biological resource center.

    Science.gov (United States)

    Forti, Tatiana; Souto, Aline da S S; do Nascimento, Carlos Roberto S; Nishikawa, Marilia M; Hubner, Marise T W; Sabagh, Fernanda P; Temporal, Rosane Maria; Rodrigues, Janaína M; da Silva, Manuela

    2016-01-01

    Considering the absence of standards for culture collections and more specifically for biological resource centers in the world, in addition to the absence of certified biological material in Brazil, this study aimed to evaluate a Fungal Collection from Fiocruz, as a producer of certified reference material and as Biological Resource Center (BRC). For this evaluation, a checklist based on the requirements of ABNT ISO GUIA34:2012 correlated with the ABNT NBR ISO/IEC17025:2005, was designed and applied. Complementing the implementation of the checklist, an internal audit was performed. An evaluation of this Collection as a BRC was also conducted following the requirements of the NIT-DICLA-061, the Brazilian internal standard from Inmetro, based on ABNT NBR ISO/IEC 17025:2005, ABNT ISO GUIA 34:2012 and OECD Best Practice Guidelines for BRCs. This was the first time that the NIT DICLA-061 was applied in a culture collection during an internal audit. The assessments enabled the proposal for the adequacy of this Collection to assure the implementation of the management system for their future accreditation by Inmetro as a certified reference material producer as well as its future accreditation as a Biological Resource Center according to the NIT-DICLA-061. Copyright © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  6. Postoperative plasma 8-iso-prostaglandin F2α levels are associated with delirium and cognitive dysfunction in elderly patients after hip fracture surgery.

    Science.gov (United States)

    Zheng, Yuan-Bo; Ruan, Guo-Mo; Fu, Jia-Xing; Su, Zhong-Liang; Cheng, Peng; Lu, Jian-Zuo

    2016-04-01

    Oxidative stress may be involved in occurrence of postoperative delirium (POD) and cognitive dysfunction (POCD). 8-iso-Prostaglandin F2α (8-iso-PGF2α), an isoprostane derived from arachidonic acid via lipid peroxidation, is considered a gold standard for measuring oxidative stress. The present study aimed to investigate the ability of postoperative plasma 8-iso-PGF2α levels to predict POD and POCD in elderly patients undergoing hip fracture surgery. Postoperative plasma 8-iso-PGF2α levels of 182 patients were measured by an enzyme-linked immunosorbent assay. We assessed the relationships between plasma 8-iso-PGF2α levels and the risk of POD and POCD using a multivariate analysis. Plasma 8-iso-PGF2α levels and age were identified as the independent predictors for POD and POCD. Based on areas under receiver operating characteristic curve, the predictive values of 8-iso-PGF2α were obviously higher than those of age for POD and POCD. In a combined logistic-regression model, 8-iso-PGF2α significantly enhanced the areas under curve of age for prediction of POD and POCD. Postoperative plasma 8-iso-PGF2α levels may have the potential to predict POD and POCD in elder patients undergoing hip fracture surgery. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. IMPLEMENTASI ISO 9001: 2000 PADA PEMBELAJARAN PRODUKTIF BIDANG KEAHLIAN BANGUNAN DI SEKOLAH MENENGAH KEJURUAN

    Directory of Open Access Journals (Sweden)

    Riban Riban

    2012-08-01

    Full Text Available The implementation of ISO 9001: 2000 in productive learning of building engineering sector in vocational education. The objtective of this study was to uncover the barriers to implementation of ISO 9001:2000 in productive learning. The study was designed using multisite study design. Tecniques of collecting the data were interview, observation to partici­pants, and documentation test. The result of the study are: (1 Implementation of the ISO 9001: 2000 in productive learning of  building engineering sector relates to the implementation of the concept of P-D-C-A in the ISO quality management system; (2 the barriers in implementation of ISO 9001:2000 in pro­ductive learning include low awareness level, inconsistencies, and disobedience; and (3 efforts to overcome the barriers to implementation of ISO 9001:2000 in produc­tive learning involve building the shared commitment, socialization in order to create together awareness, supervising, and doing the preventive action. Implementasi ISO 9001: 2000 pada Pembelajaran Produktif Bidang Keahlian Bangunan di Sekolah Menengah Kejuruan. Penelitian ini bermaksud meng­ungkap lebih mendalam tentang, imple­men­­­tasi, hambatan-hambatan, dan upaya-upaya dalam mengatasi ham­batan penerap­an ISO 9001: 2000 pada pembelajaran produktif. Penelitian ini diran­cang dengan menggunakan rancangan studi multisitus. Teknik pengum­pulan data meliputi wawan­cara, observasi partisipan, dan studi dokumentasi. Temuan penelitian adalah: (1 Penerapan ISO 9001: 2000 pada pem­belajaran pro­duktif teknik bangunan mengacu pada konsep P-D-C-A ke dalam sistem manajemen mutu ISO; (2 hambatan implementasi ISO 9001: 2000 pada pem­bel­ajaran produktif meliputi tingkat kesadaran rendah, inkonsistensi, dan ketidak­taatasasan; dan (3 upaya mengatasi hambatan dalam implementasi ISO 9001: 2000 pada pembelajar­an produk­tif meliputi membangun komitmen bersama, sosialisasi dalam rangka me­num­buhkan kesadaran bersama

  8. ISO 26000 – An Integrative Approach of Corporate Social Responsibility

    Directory of Open Access Journals (Sweden)

    Herciu Mihaela

    2016-04-01

    Full Text Available ISO 26000 represents a guidance on corporate social responsibility and it is, at the present time, one of the most important document on CSR in the world. Without being mandatory or regulated, ISO 26000 is focus on seven core subjects that have to be approached synergistic – governance, human right, labor, environment, business practices, consumer, and community – in order to achieve its goal. The present paper intends to present and analyze the seven core subjects of ISO 26000 from tow perspectives: by emphasizing the benefits of implementing the standard into the business strategy and by revealing the correlation between corporate social responsibility and sustainable development.

  9. Ignoring 'Best Practice': why Irish software SMEs are rejecting CMMI and ISO 9000

    OpenAIRE

    O'Connor, Rory V.; Coleman, Gerry

    2009-01-01

    peer-reviewed Software Process Improvement (SPI) "best practice" models such as ISO 9000 and the Capability Maturity Model Integrated (CMMI) have been developed to assist software development organisations by harnessing their experience and providing them with support so that they can produce software products on time, within budget and to a high level of quality. However there is increasing evidence that these models are not being adopted by Small and Medium sized Enterprises ...

  10. Age, colors and ISO standards

    NARCIS (Netherlands)

    Nes, van F.L.; Eschbach, R; Marcu, G.G.; Tominaga, S.; Rizzi, A.

    2010-01-01

    Age influences all bodily functions, also vision. Therefore, the effects of age on vision should be mirrored in ergonomic requirements laid down in display standards such as ISO 9241-300/307, 'Electronic visual display requirements'. However, this is only true to a limited extent - just as is the

  11. ISO 14001: time for improvements?

    DEFF Research Database (Denmark)

    Jørgensen, Tine Herreborg

    2007-01-01

    The aim of this paper is to discuss a number of issues related to ISO 14001:2004, the international standard for Environmental Management Systems (EMS) with the purpose of improving the next edition in order to recognise and reflect new recognitions in approaches to pollution prevention. A case...

  12. Specification of Energy Assessment Methodologies to Satisfy ISO 50001 Energy Management Standard

    Science.gov (United States)

    Kanneganti, Harish

    Energy management has become more crucial for industrial sector as a way to lower their cost of production and in reducing their carbon footprint. Environmental regulations also force the industrial sector to increase the efficiency of their energy usage. Hence industrial sector started relying on energy management consultancies for improvements in energy efficiency. With the development of ISO 50001 standard, the entire energy management took a new dimension involving top level management and getting their commitment on energy efficiency. One of the key requirements of ISO 50001 is to demonstrate continual improvement in their (industry) energy efficiency. The major aim of this work is to develop an energy assessment methodology and reporting format to tailor the needs of ISO 50001. The developed methodology integrates the energy reduction aspect of an energy assessment with the requirements of sections 4.4.3 (Energy Review) to 4.4.6 (Objectives, Targets and Action Plans) in ISO 50001 and thus helping the facilities in easy implementation of ISO 50001.

  13. Implementation of ISO 10110 optics drawing standards for the National Ignition Facility

    International Nuclear Information System (INIS)

    Aikens, D. M.; English, R. E.; Wang, D. Y.

    1999-01-01

    The National Ignition Facility (NIF) project elected to implement ISO 10110 standard for the specifications of NIF optics drawings in 1996. More than 7,000 NIF large optics and 20,000 NIF small optics will be manufactured based on ISO 10110 indications. ISO 10110 standard meets many of the needs of the NIF optics specifications. It allows the optical engineer to quantify and clearly communicate the desired optical specifications. While no single drawing standard specifies all the requirements of high energy laser system, a combination of ISO 10110 standard with detailed notes make it possible to apply international drawing standards to the NIF laser system. This paper will briefly describe LLNL's interpretation and implementation of the ISO 10110 drawing standard, present some examples of NIF optics drawings, and discuss pros and cons of the indications from the perspective of this application. Emphasis will be given to the surface imperfection specifications, known as 5/, for the NIF optics

  14. Implementation of ISO 10110 optics drawing standards for the National Ignition Facility

    Science.gov (United States)

    Wang, David Y.; English, R. Edward, Jr.; Aikens, David M.

    1999-11-01

    The National Ignition Facility (NIF) project elected to implement ISO 10110 standard for the specifications of NIF optics drawings in 1996. More than 7,000 NIF large optics and 20,000 NIF small optics will be manufactured based on ISO 10110 indications. ISO 10110 standard meets many of the needs of the NIF optics specifications. It allows the optical engineer to quantify and clearly communicate the desired optical specifications. While no single drawing standard specifies all the requirements of high energy laser system, a combination of ISO 10110 standard with detailed notes make it possible to apply international drawing standards to the NIF laser system. This paper will briefly describe LLNL's interpretation and implementation of the ISO 10110 drawing standard, present some examples of NIF optics drawings, and discuss pros and cons of the indications from the perspective of this application. Emphasis will be given to the surface imperfection specifications, known as 5/, for the NIF optics.

  15. 75 FR 5779 - Notice Providing Agenda for Technical Conference on RTO/ISO Responsiveness

    Science.gov (United States)

    2010-02-04

    ... Conference on RTO/ISO Responsiveness January 27, 2010. California Independent System Operator Docket No. ER09.... Southwest Power Pool, Inc Docket Nos. ER09-1050-000, ER09- 1192-000. ISO New England, Inc. and New England.... Agenda--Technical Conference on RTO/ISO Responsiveness February 4, 2010 12:30 Panel 1--Stakeholder...

  16. ISO 9000 Series Certification Over Time: what have we learnt?

    NARCIS (Netherlands)

    A. van der Wiele (Ton); A.M. Brown (Alan)

    2002-01-01

    textabstractThe ISO 9000 experiences of the same sample of organisations over a five year time period is examined in this paper. The responses to a questionnaire sent out at the end of 1999 to companies which had a reasonably long term experience with the ISO 9000 series quality system are analysed.

  17. Quality standards: Comparison between IAEA 50-C/SG-Q and ISO 9001:2000

    International Nuclear Information System (INIS)

    2002-01-01

    The International Atomic Energy Agency (IAEA) has the statutory mandate to seek to accelerate and enlarge the contribution of atomic energy to peace, health and prosperity throughout the world. As part of the activities to achieve its objectives, the IAEA is authorized to establish standards of safety for the protection of health and the minimization of danger to life and property. The standards of safety developed by the IAEA are recommendations for use by its Member States in the framework of national regulations for the safe utilization of nuclear energy. Such standards should be considered as nuclear safety regulatory documents. The standards developed by the International Organization for Standardization (ISO) are complementary technical documents emphasizing industrial application and contractual aspects. Regarding the quality assurance topic, the IAEA developed the publication Safety Series No. 50-C/SG-Q, Quality Assurance for Safety in Nuclear Power Plants and other Nuclear Installations, which is mostly used directly or indirectly to establish the nuclear safety requirements at the nuclear utility-regulator interface. The ISO 9001:2000 standard, Quality Management Systems Requirements, is often used to define the quality management system requirements at the utility-supplier interface. The relationship between the IAEA and ISO quality standards is growing in significance owing to their increasing impact upon utilities (owners/operators of nuclear facilities) and their contractors/suppliers. The relationship between the IAEA and ISO standards is considered critical in particular with respect to contractors/suppliers with a small range of nuclear supplies. These contractors-suppliers are not always willing to prepare special quality assurance programmes based on nuclear safety standards. On the other hand, these contractors/suppliers may be qualified on the basis of the ISO quality standard. In any case, for delivering nuclear items and services the

  18. Virtual Reference, Real Money: Modeling Costs in Virtual Reference Services

    Science.gov (United States)

    Eakin, Lori; Pomerantz, Jeffrey

    2009-01-01

    Libraries nationwide are in yet another phase of belt tightening. Without an understanding of the economic factors that influence library operations, however, controlling costs and performing cost-benefit analyses on services is difficult. This paper describes a project to develop a cost model for collaborative virtual reference services. This…

  19. Mainstream Smoke Chemistry and in Vitro and In Vivo Toxicity of the Reference Cigarettes 3R4F and 2R4F

    Directory of Open Access Journals (Sweden)

    Roemer E

    2014-12-01

    Full Text Available A new reference cigarette, the 3R4F, has been developed to replace the depleting supply of the 2R4F cigarette. The present study was designed to compare mainstream smoke chemistry and toxicity of the two reference cigarettes under the International Organization for Standardization (ISO machine smoking conditions, and to further compare mainstream smoke chemistry and toxicological activity of the 3R4F cigarette by two different smoking regimens, i.e., the machine smoking conditions specified by ISO and the Health Canada intensive (HCI smoking conditions.

  20. Data Modeling Challenges of Advanced Interoperability.

    Science.gov (United States)

    Blobel, Bernd; Oemig, Frank; Ruotsalainen, Pekka

    2018-01-01

    Progressive health paradigms, involving many different disciplines and combining multiple policy domains, requires advanced interoperability solutions. This results in special challenges for modeling health systems. The paper discusses classification systems for data models and enterprise business architectures and compares them with the ISO Reference Architecture. On that basis, existing definitions, specifications and standards of data models for interoperability are evaluated and their limitations are discussed. Amendments to correctly use those models and to better meet the aforementioned challenges are offered.

  1. Nonparametric decision tree: The impact of ISO 9000 on certified and non certified companies Nonparametric decision tree: The impact of ISO 9000 on certified and non certified companies Nonparametric decision tree: The impact of ISO 9000 on certified and non certified companies

    Directory of Open Access Journals (Sweden)

    Joaquín Texeira Quirós

    2013-09-01

    Full Text Available Purpose: This empirical study analyzes a questionnaire answered by a sample of ISO 9000 certified companies and a control sample of companies which have not been certified, using a multivariate predictive model. With this approach, we assess which quality practices are associated to the likelihood of the firm being certified. Design/methodology/approach: We implemented nonparametric decision trees, in order to see which variables influence more the fact that the company be certified or not, i.e., the motivations that lead companies to make sure. Findings: The results show that only four questionnaire items are sufficient to predict if a firm is certified or not. It is shown that companies in which the respondent manifests greater concern with respect to customers relations; motivations of the employees and strategic planning have higher likelihood of being certified. Research implications: the reader should note that this study is based on data from a single country and, of course, these results capture many idiosyncrasies if its economic and corporate environment. It would be of interest to understand if this type of analysis reveals some regularities across different countries. Practical implications: companies should look for a set of practices congruent with total quality management and ISO 9000 certified. Originality/value: This study contributes to the literature on the internal motivation of companies to achieve certification under the ISO 9000 standard, by performing a comparative analysis of questionnaires answered by a sample of certified companies and a control sample of companies which have not been certified. In particular, we assess how the manager’s perception on the intensity in which quality practices are deployed in their firms is associated to the likelihood of the firm being certified.Purpose: This empirical study analyzes a questionnaire answered by a sample of ISO 9000 certified companies and a control sample of companies

  2. Reinterpreting the best biomarker of oxidative stress: The 8-iso-prostaglandin F2α/prostaglandin F2α ratio shows complex origins of lipid peroxidation biomarkers in animal models.

    Science.gov (United States)

    Van't Erve, Thomas J; Lih, Fred B; Jelsema, Casey; Deterding, Leesa J; Eling, Thomas E; Mason, Ronald P; Kadiiska, Maria B

    2016-06-01

    Oxidative stress is elevated in numerous environmental exposures and diseases. Millions of dollars have been spent to try to ameliorate this damaging process using anti-oxidant therapies. Currently, the best accepted biomarker of oxidative stress is the lipid oxidation product 8-iso-prostaglandin F2α (8-iso-PGF2α), which has been measured in over a thousand human and animal studies. 8-iso-PGF2α generation has been exclusively attributed to nonenzymatic chemical lipid peroxidation (CLP). However, 8-iso-PGF2α can also be produced enzymatically by prostaglandin-endoperoxide synthases (PGHS) in vivo. When failing to account for PGHS-dependent generation, 8-iso-PGF2α cannot be interpreted as a selective biomarker of oxidative stress. We investigated the formation of 8-iso-PGF2α in rats exposed to carbon tetrachloride (CCl4) or lipopolysaccharide (LPS) using the 8-iso-PGF2α/PGF2α ratio to quantitatively determine the source(s) of 8-iso-PGF2α. Upon exposure to a 120mg/kg dose of CCl4, the contribution of CLP accounted for only 55.6±19.4% of measured 8-iso-PGF2α, whereas in the 1200mg/kg dose, CLP was the predominant source of 8-iso-PGF2α (86.6±8.0% of total). In contrast to CCl4, exposure to 0.5mg/kg LPS was characterized by a significant increase in both the contribution of PGHS (59.5±7.0) and CLP (40.5±14.0%). In conclusion, significant generation of 8-iso-PGF2α occurs through enzymatic as well as chemical lipid peroxidation. The distribution of the contribution is dependent on the exposure agent as well as the dose. The 8-iso-PGF2α/PGF2α ratio accurately determines the source of 8-iso-PGF2α and provides an absolute measure of oxidative stress in vivo. Copyright © 2016. Published by Elsevier Inc.

  3. ISO 14001: implementar ou não? Uma proposta para a tomada de decisão ISO 14001: adopt it or not? A proposal for the decision making process

    Directory of Open Access Journals (Sweden)

    Giuliano Nacarato Moretti

    2008-12-01

    Full Text Available Entre as vantagens e desvantagens oferecidas pela implementação da norma ISO 14001, o empresário, muitas vezes, não encontra subsídios suficientes para a tomada de decisão pela adoção ou não da referida norma. Este trabalho apresenta uma ferramenta de auxílio à tomada de decisão empresarial, promovendo um estudo sobre a real necessidade e viabilidade da implementação da norma ISO 14001 e a respectiva certificação. Trata-se de uma análise multicriterial, em que se verifica a compatibilidade entre o perfil organizacional e a norma ISO 14001. Busca-se facilitar a decisão das organizações em adotar ou não a ISO 14001, por meio de uma recomendação que aumente sua probabilidade de atingir os objetivos almejados. A ferramenta demonstrou sua forte aplicabilidade quando implementada em duas empresas.One of the difficulties of the decision making process, is that many entrepreneurs may find themselves incapable of finding enough subsidies for the decision of adopting or not the ISO 14001 standard. This work presents a tool that facilitates corporate decision making, providing a thorough analysis of the real necessity and feasibility of the implementation of the ISO 14001 standard and its certification. This tool consists of a multicriterial analysis, in which is possible to verify the compatibility between the organizational profile and the ISO 14001 standard. This recommendation of adopting or not the ISO 14001 standard seeks to facilitate the organization decision making; and, as a result, it also enhances the probability of the organization attaining its objectives. This tool presented a strong applicability when implemented in two companies.

  4. PERBANDINGAN IMPLEMENTASI ISO DAN PELUNCURAN ENTERPRISE RESOURCES PLANNING TERHADAP INDEKS KINERJA KEUANGAN

    Directory of Open Access Journals (Sweden)

    Sautma Ronni Basana

    2017-03-01

    Full Text Available Recently, companies implemented projects which applied on companies’ overall system. These recent bestpractices of pursuing companies’ effectiveness and efficiency would be implementation of ISO 9000 and ERP.Previous research showed that these two projects could bring benefits for these companies which implementedit. However, it had not been compared which project would bring more benefits to these companies. Thisresearch observed 35 companies which consisted of 15 companies in food and beverages industry, 9 companiesin pharmaceutical industry, 4 companies in cigarettes industry, 4 companies in cosmetics industry, and 3companies in household appliances industry. The data were taken by observing and recording the valueswhich related to COGS (cost of goods sold, total inventory, net income, gross income, operating income, pretaxincome, cash flow operation, total liabilities, and total asset after ISO and ERP implementation. The resultsshowed that there was no significant difference of the ISO and ERP implementation on the factors of inventoryturnover, and weeks of supply. While the other factors showed significant differences between the implementationof ERP and ISO. Net profit margin, gross profit margin, and operating profit margin showed better resulton ERP launching. On the other hand, pretax margin showed better than ISO 9000 implementation. Overall,ERP implementation showed better results compared with ISO 9000.

  5. Iso-vector form factors of the delta and nucleon in QCD sum rules

    International Nuclear Information System (INIS)

    Ozpineci, A.

    2012-01-01

    Form factors are important non-perturbative properties of hadrons. They give information about the internal structure of the hadrons. In this work, iso-vector axial-vector and iso-vector tensor form factors of the nucleon and the iso-vector axial-vector Δ→N transition form factor calculations in QCD Sum Rules are presented.

  6. A search for PAHs in the ISO spectra of comet Hale-Bopp

    Science.gov (United States)

    Crovisier, J.; Bockelée-Morvan, D.

    2007-12-01

    From a new analysis of a spectrum of comet C/1995 O1 (Hale-Bopp) obtained with the Infrared Space Observatory (ISO), Lisse et al. (2007) claimed the identification of many new dust species. Among them are PAHs, which were not found in our first analysis of the ISO spectra. We present a re-examination of the ISO observations of comet Hale-Bopp, which does not confirm the conclusion of Lisse et al.

  7. U-value measurements on ISO round Robin window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1997-01-01

    9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust.......9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust....

  8. The new ISO 6579-1: A real horizontal standard for detection of Salmonella, at last!

    Science.gov (United States)

    Mooijman, Kirsten A

    2018-05-01

    Up to 2016, three international standard methods existed for the detection of Salmonella spp. in food, animal feed and samples from the primary production stage: ISO 6785:2001 for milk and milk products, ISO 6579:2002 for (other) food and animal feed and Annex D of ISO 6579:2007 for samples from the primary production stage. In 2009, an ISO/CEN working group started with the revision of ISO 6579:2002 with two main aims: combining the three aforementioned standards in one document and improving the information in ISO 6579:2002. Additionally it was decided to split ISO 6579 into three parts, where part 1 describes the detection, part 2 the enumeration by mini-MPN (published in 2012) and part 3 the serotyping of Salmonella (published in 2014). This paper describes the experiments and choices made for improving the part on detection of Salmonella (ISO 6579-1). The final voting stage on (draft) ISO 6579-1 was finished by the end of December 2016, with a positive outcome. Finally, a real horizontal standard became available for detection of Salmonella in food, animal feed, environmental samples in the area of food production and food handling and in samples from the primary production stage in 2017. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. α-Iso-cubebene exerts neuroprotective effects in amyloid beta stimulated microglia activation.

    Science.gov (United States)

    Park, Sun Young; Park, Se Jin; Park, Nan Jeong; Joo, Woo Hong; Lee, Sang-Joon; Choi, Young-Whan

    2013-10-25

    Schisandra chinensis is commonly used for food and as a traditional remedy for the treatment of neuronal disorders. However, it is unclear which component of S. chinensis is responsible for its neuropharmacological effects. To answer this question, we isolated α-iso-cubebene, a dibenzocyclooctadiene lignin, from S. chinensis and determined if it has any anti-neuroinflammatory and neuroprotective properties against amyloid β-induced neuroinflammation in microglia. Microglia that are stimulated by amyloid β increased their production of pro-inflammatory cytokines and chemokines, prostaglandin E2 (PGE2), nitric oxide (NO) and reactive oxygen species (ROS) and the enzymatic activity of matrix metalloproteinase 9 (MMP-9). We found this was all inhibited by α-iso-cubebene. Consistent with these results, α-iso-cubebene inhibited the expression of inducible nitric oxide synthase (iNOS), cyclooxygenase 2 (COX-2) and MMP-9 in amyloid β-stimulated microglia. Subsequent mechanistic studies revealed that α-iso-cubebene inhibited the phosphorylation and degradation of IκB-α, the phosphorylation and transactivity of NF-κB, and the phosphorylation of MAPK in amyloid β-stimulated microglia. These results suggest that α-iso-cubebene impairs the amyloid β-induced neuroinflammatory response of microglia by inhibiting the NF-κB and MAPK signaling pathways. Importantly, α-iso-cubebene can provide critical neuroprotection for primary cortical neurons against amyloid β-stimulated microglia-mediated neurotoxicity. To the best of our knowledge, this is the first report showing that α-iso-cubebene can provide neuroprotection against, and influence neuroinflammation triggered by, amyloid β activation of microglia. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. ISO sertifikaat aitab otsustada / Toomas Udu

    Index Scriptorium Estoniae

    Udu, Toomas

    2005-01-01

    Ilmunud ka: Delovõje Vedomosti : Transport i logistika 25. mai lk. 8. Teenuse kvaliteedi näitajad logistikafirmas ISO standardi alusel. Vt. samas: Eestis kasutatakse kolme kvaliteedistandardit; Kuidas mõjutada kvaliteeti läbi juhtimissüsteemi

  11. Air Force Systems Engineering Assessment Model (AF SEAM) Management Guide, Version 2

    Science.gov (United States)

    2010-09-21

    gleaned from experienced professionals who assisted with the model’s development. Examples of the references used include the following: • ISO /IEC...Defense Acquisition Guidebook, Chapter 4 • AFI 63-1201, Life Cycle Systems Engineering • IEEE/EIA 12207 , Software Life Cycle Processes • Air...Selection criteria Reference Material: IEEE/EIA 12207 , MIL-HDBK-514 Other Considerations: Modeling, simulation and analysis techniques can be

  12. Gaining competitive advantage in personal dosimetry services through ISO 9001 certification

    International Nuclear Information System (INIS)

    Noriah, M.A.

    2005-01-01

    Full text: In Malaysia, the harmonization of dose monitoring for almost 12,000 radiation workers is assigned to the Secondary Standard Dosimetry Laboratory of Malaysian Institute for Nuclear Technology Research, SSDL-MINT. Established in 1980, SSDL-MINT is responsible for improving personal and workplace safety by providing high quality personal dosimetry services. It is important to demonstrate that the performance of personal dosimetry meets recognized standards, to ensure radiation doses to individual workers are within the safe limits and to verify compliance with dose limits. Concern on the quality of personal dosimetry service began to be expressed in 2000. The concern led to the ISO certification, which brought an unprecedented effort characterized by high degree coordination, proper documentation and well trained of personal dosimetry operators. These huge efforts resulted with certification ISO 9002:1994 by the SIRIM International QAS Sdn. Bhd. in January 2002. The adoption of these requirements for the ISO 9002 standard makes routine handling of the process easier, and increases the reliability and effectiveness of the services. This helps to increase the quality and uniformity of personal dosimetry. The revision of the ISO 9002:1994 to ISO 9001:2000 necessitated SSDL-MINT revising its quality management system. The work began in middle 2002, and by May 2003, SSDL-MINT has been upgraded to ISO 9001:2000. Certification to the ISO 9001:2000 demonstrates our ability to consistency provide service that meets the requirements of the customer and the regulatory authority. These includes: improved consistency of service / product performance and therefore higher customer satisfaction levels; uniformity in work processes across organizations; simplified and more uniform structure for quality documents; improved customer perception of the organizations image, culture and performance; reduced number of product and process non-conformances; greater employee

  13. PYME y cooperativas ante el reto de la RSE: la nueva ISO 26000 (SMEs and cooperatives confront the challenge of CSR: the new ISO 26000

    Directory of Open Access Journals (Sweden)

    Juan Pablo Landa

    2012-05-01

    Full Text Available Corporate Social Responsibility is a central issue in modern business and a main factor of companies strategies for competitiveness in a global economy . The recent approval of ISO26000 shows this general tendency to introduce social and environmental principles in global governance and organizational behaviour in all kinds of firms, organizations and multinational corporations. This paper offers a critical approach to the effects of ISO 26000 in the small and medium companies, and cooperatives, too. This norm is not focussed on the particularities of this kind of companies and shows some problems when implementing it in SME & social economy organizations. The question which comes up is if there is a necessity to adapt the implementation of ISO 26000 to these particular firms: in which cases and to what limits. La Responsabilidad Social Corporativa es una cuestión central en la economía moderna, y un factor fundamental en las estrategias competitivas de las empresas, en el marco de una economía globalizada. La reciente aprobación de la norma ISO 26000 recoge la tendencia general de introducir principios sociales y medioambientales en el gobierno global y en la organización de todo tipo de empresas, organizaciones y corporaciones multinacionales. Este artículo ofrece un acercamiento crítico a los efectos de la norma ISO 26000 en las PYMEs y cooperativas. Esta norma no contempla las particularidades de este tipo de compañías, y muestra algunos problemas al implantarlas en PYMEs y organizaciones de la economía social. Se cuestiona la necesidad de adaptar la implementación de la norma ISO 26000 a este tipo de organizaciones, en qué casos, y con qué limites.DOWNLOAD THIS PAPER FROM SSRN: http://ssrn.com/abstract=2049865

  14. The use of a reference absorber for absorption measurements in a reverberation chamber

    DEFF Research Database (Denmark)

    Nolan, Melanie; Vercammen, Martijn; Jeong, Cheol-Ho

    2014-01-01

    The statistical incidence absorption coefficient is measured in a reverberation room according to ISO 354. This absorption coefficient is referred to as Sabine absorption coefficient, which assumes the chambe r to be completely diffuse. It is known that the reproducibility of these results is poo...

  15. Certified quality management according to DIN ISO 9001 in a radiology department at a university hospital. Measurable changes in academic quality indicators?; Qualitaetsmanagement nach DIN ISO 9001 an einer radiologischen Universitaetsklinik. Messbare Veraenderungen der universitaeren Kennzahlen nach der Zertifizierung?

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzen, Joern; Habermann, C.; Weber, C.; Adam, G.; Koops, A. [Diagnostikzentrum, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Utler, C. [Geschaeftsbereich Qualitaetsmanagement, Universitaetsklinikum Hamburg-Eppendorf (Germany); Grzyska, U. [Diagnostikzentrum, Klinik und Poliklinik fuer Neuroradiologische Diagnostik und Intervention, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2009-10-15

    Purpose: to evaluate the changes in academic quality indicators after implementation of a quality management system according to DIN ISO 9001:2000. Materials and methods: after implementation and certification of a quality management system, the actual state based on quality indicators from the fields of student teaching, research, continuing education and the satisfaction of referring physician was determined. After implementation of an action plan for the individual areas, the temporal changes in the ratios were documented in the follow-up. Results: the evaluation of teaching performance obtained by questionnaire among the students of the radiology course showed a steady increase in satisfaction (mean value 2003: 2.7; 2007: 3.9). In the field of research an increase in scientific output was achieved based on the number of an internal publication score (2002: 99 points; 2006: 509). Repeated opinion surveys among our referring physicians found improvements in indicators for the appointment of investigations, consulting service and waiting times for the investigation, while the waiting times for internal transport service did not improve. Exemplary measurements of the success of the advanced training of the staff demonstrated the need for continuing education for quality improvement. Conclusion: the evaluation of quality indicators showed over time a measurable positive impact on processes of a radiological Univ. Hospital after implementation of a QM system according to DIN ISO 9001:2000. (orig.)

  16. Um refinamento da estrutura da camada de aplicação do RM-OSI/ISO e aspectos de sua implementação em um sistema didatico de comunicação

    OpenAIRE

    Flavio Morais de Assis Silva

    1993-01-01

    Resumo: Esta dissertação consiste de Uma definição mais precisa de funcionalidades para os componentes da camada de Aplicação do RM-OSI/ISO (Reference Model - Open Systems Interconection / International Organization for Standardization). Esta definição de funcionalidades tem a finalidade de esclarecer os relacionamentos que há entre os componentes desta camada e de servir de uma base conceitual, a partir da qual estruturas para implementações possam ser derivadas. As funcionalidades apresenta...

  17. Occupational exposures at nuclear power plants. Twelfth annual report of the Isoe programme, 2002

    International Nuclear Information System (INIS)

    2004-01-01

    The Information System on Occupational Exposure (ISOE) was created by the OECD Nuclear Energy Agency in 1992 to promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The ISOE Programme provides experts in occupational radiation protection with a forum for communication and exchange of experience. The ISOE databases enable the analysis of occupational exposure data from the 465 commercial nuclear power plants participating in the Programme (representing some 90 per cent of the world's total operating commercial reactors). The Twelfth Annual Report of the ISOE Programme summarises achievements made during 2002 and compares annual occupational exposure data. Principal developments in ISOE participating countries are also described. (author)

  18. ISO 50001 for US Commercial Buildings - Current Status and Opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jingjing; Sheaffer, Paul

    2017-12-01

    ''ISO 50001: 2011 Energy management systems – Requirements with guidance for use'' is a voluntary International Standard which provides organizations a proven framework to manage energy and continuously improve their energy performance. Implementing ISO 50001 in the commercial building sector has its unique opportunities and challenges in comparison with the industrial sector. The energy footprint of a portfolio of commercial buildings can be just as significant as a large industrial facility in comparison. There are many energy-saving opportunities in commercial buildings that can be addressed without capital investments, and the perceived risks for making energy improvements can be lower than in the industrial sector. In addition, the energy-consuming systems in commercial buildings are limited in types and have many similarities across buildings, which makes it much easier to standardize many ISO 50001 required processes, 5 procedures and documents to simplify implementation. There are also some sector-unique challenges, such as less familiar with ISO systems and the certification process. Another challenge arises from the complexity in some buildings’ ownership, tenancy, and O&M responsibilities. This whitepaper discusses these opportunities and issues in detail. The paper also recommends the characteristics of organizations in the commercial building sector that can benefit the most from adopting the ISO 50001 standard – namely the “suitable market”. Eight segments (education, food sales, retail, inpatient health care, hospitality, office buildings, laboratories and data centers) within the commercial building sector are highlighted.

  19. The ISO9000 standard in electrical research

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Ortiz, G.; Davila-Nunez, G.; Gonzalez-Sustaeta, J. [Inst. de Investigaciones Electricas, Cuernavaca (Mexico). Unidad de Sistemas Informaticos

    1999-11-01

    In this article, the main aspects that are considered important upon applying the ISO9000 standard [ISO 94] in a research institution, company, or group, are described. The 20 sections of the standard are discussed emphasizing the concepts and definitions that can be differently interpreted in the process of elaboration of a quality manual for a group devoted to research, than when they are applied in the elaboration of a manual for a factory that produces material goods. The exposed reasoning was used in the elaboration of the quality manual in the Information Systems Unit of the Electrical Research Institute in Mexico, and it is being used in the installation and operation of the quality system.

  20. Nuclear energy - Reference beta-particle radiation - Part 2: Calibration fundamentals related to basic quantities characterizing the radiation field

    International Nuclear Information System (INIS)

    2004-01-01

    ISO 6980 consists of the following parts, under the general title Nuclear energy - Reference beta-particle radiation: Part 1: Method of production; Part 2: Calibration fundamentals related to basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of their response as a function of energy and angle of incidence. This part 2 of ISO 6980 specifies methods for the measurement of the directional absorbed-dose rate in a tissue-equivalent slab phantom in the ISO 6980 reference beta-particle radiation fields. The energy range of the beta-particle-emitting isotopes covered by these reference radiations is 0.066 to 3.54 MeV (maximum energy). Radiation energies outside this range are beyond the scope of this standard. While measurements in a reference geometry (depth of 0.07 mm at perpendicular incidence in a tissue-equivalent slab phantom) with a reference class extrapolation chamber are dealt with in detail, the use of other measurement systems and measurements in other geometries are also described, although in less detail. The ambient dose equivalent, H*(10) as used for area monitoring of strongly penetrating radiation, is not an appropriate quantity for any beta radiation, even for that penetrating a 10 mm thick layer of ICRU tissue (i.e. E max > 2 MeV). If adequate protection is provided at 0.07 mm, only rarely will one be concerned with other depths, for example 3 mm. This document is geared towards organizations wishing to establish reference-class dosimetry capabilities for beta particles, and serves as a guide to the performance of dosimetry with the reference class extrapolation chamber for beta-particle dosimetry in other fields. Guidance is also provided on the statement of measurement uncertainties

  1. Reference Inflow Characterization for River Resource Reference Model (RM2)

    Energy Technology Data Exchange (ETDEWEB)

    Neary, Vincent S [ORNL

    2011-12-01

    Sandia National Laboratory (SNL) is leading an effort to develop reference models for marine and hydrokinetic technologies and wave and current energy resources. This effort will allow the refinement of technology design tools, accurate estimates of a baseline levelized cost of energy (LCoE), and the identification of the main cost drivers that need to be addressed to achieve a competitive LCoE. As part of this effort, Oak Ridge National Laboratory was charged with examining and reporting reference river inflow characteristics for reference model 2 (RM2). Published turbulent flow data from large rivers, a water supply canal and laboratory flumes, are reviewed to determine the range of velocities, turbulence intensities and turbulent stresses acting on hydrokinetic technologies, and also to evaluate the validity of classical models that describe the depth variation of the time-mean velocity and turbulent normal Reynolds stresses. The classical models are found to generally perform well in describing river inflow characteristics. A potential challenge in river inflow characterization, however, is the high variability of depth and flow over the design life of a hydrokinetic device. This variation can have significant effects on the inflow mean velocity and turbulence intensity experienced by stationary and bottom mounted hydrokinetic energy conversion devices, which requires further investigation, but are expected to have minimal effects on surface mounted devices like the vertical axis turbine device designed for RM2. A simple methodology for obtaining an approximate inflow characterization for surface deployed devices is developed using the relation umax=(7/6)V where V is the bulk velocity and umax is assumed to be the near-surface velocity. The application of this expression is recommended for deriving the local inflow velocity acting on the energy extraction planes of the RM2 vertical axis rotors, where V=Q/A can be calculated given a USGS gage flow time

  2. KSC Center Director Bridges accepts an ISO 9001 certification plaque from DNV

    Science.gov (United States)

    1998-01-01

    Center Director Roy Bridges (right) displays the 2000th ISO Certificate Plaque he was given by Dalton Lyon (left) of Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. The plaque is a representation of the ISO 9001 certification awarded to KSC by DNV. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world- class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification.

  3. Step of quality assurance preparation on ISO 9001:2000 toward certification

    International Nuclear Information System (INIS)

    Agustiar

    2007-01-01

    ISO 9001:2000 is the International Standard for the quality management system that stipulate requirement and recommendation provided for design until product. The standard is also regulated the implementation and evaluation from management system point of view the objective to assure organization will meet specified requirement product. To propose ISO 9001:2000 certification, many steps of action should be carried out. There are 5 primary sections of the quality management system requirements of ISO 9001:2000. Quality Management system, Management responsibility, Resource management, Product realization and Measurement, Analysis and improvement, in which all will be begun with training until evaluation (author)

  4. Predicting the quantifiable impacts of ISO 50001 on climate change mitigation

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee; Therkelsen, Peter; Scodel, Anna; Rao, Prakash; Aghajanzadeh, Arian; Hirzel, Simon; Zhang, Ruiqin; Prem, Richard; Fossa, Alberto; Lazarevska, Ana M.; Matteini, Marco; Schreck, Bettina; Allard, Fabian; Villegal Alcántar, Noé; Steyn, Karel; Hürdoğan, Ertaç; Björkman, Thomas; O' Sullivan, John

    2017-08-01

    The ISO 50001-Energy management standard provides a continual improvement framework for organizations to reduce their energy consumption, which in the industrial and commercial (service) sectors, accounts for nearly 40% of global greenhouse gas emissions. Reducing this energy consumption will be critical for countries to achieve their national greenhouse gas reduction commitments. Several national policies already support ISO 50001; however, there is no transparent, consistent process to estimate the potential impacts of its implementation. This paper presents the ISO 50001 Impacts Methodology, an internationally-developed methodology to calculate these impacts at a national, regional, or global scale suitable for use by policymakers. The recently-formed ISO 50001 Global Impacts Research Network provides a forum for policymakers to refine and encourage use of the methodology. Using this methodology, a scenario with 50% of projected global industrial and service sector energy consumption under ISO 50001 management by 2030 would generate cumulative primary energy savings of approximately 105 EJ, cost savings of nearly US $700 billion (discounted to 2016 net present value), and 6500 million metric tons (Mt) of avoided CO2 emissions. The avoided annual CO2 emissions in 2030 alone are equivalent to removing 210 million passenger vehicles from the road.

  5. An iso-α-acid-rich extract from hops (Humulus lupulus) attenuates acute alcohol-induced liver steatosis in mice.

    Science.gov (United States)

    Hege, Marianne; Jung, Finn; Sellmann, Cathrin; Jin, Chengjun; Ziegenhardt, Doreen; Hellerbrand, Claus; Bergheim, Ina

    2018-01-01

    Results of in vitro and in vivo studies suggest that consumption of beer is less harmful for the liver than consumption of spirits. It also has been suggested that secondary plant compounds derived from hops such as xanthohumol or iso-α-acids may have beneficial effects on the development of liver diseases of various etiologies. The aim of this study was to determine whether iso-α-acids consumed in doses achieved by "normal" beer consumption have beneficial effects on health. Female C57 Bl/6 J mice, pretreated for 4 d with an iso-α-acid-rich extract (∼30% iso-α-acids from hops, 0.75 mg/kg body weight), were fed one bolus of ethanol (6 g/kg body weight intragastric) or an iso-caloric maltodextrin solution. Markers of liver damage, toll-like receptor-4 signaling, and lipid peroxidation were determined. Furthermore, the effect of isohumulone on the lipopolysaccharide-dependent activation of J774 A.1 macrophages, used as a model of Kupffer cells, was determined. In the liver, acute ethanol administration led to a significant accumulation of fat (∼10-fold), which was accompanied by significantly higher inducible nitric oxide synthase protein level, elevated nitric oxide production, and increased plasminogen activator inhibitor 1 protein concentration when compared to controls. In mice pretreated with iso-α-acids, these effects of alcohol were markedly attenuated. Pretreatment of J774 A.1 macrophages with isohumulone significantly attenuated lipopolysaccharide-induced mRNA expression of inducible nitric oxide synthase and interleukin-6 as well as the release of nitric oxide. Taken together, iso-α-acids markedly attenuated the development of acute alcohol-induced damage in mice. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. The Role of ISO 9000 Certification on Waste Management of Leather Industry

    International Nuclear Information System (INIS)

    Susetyo Hario Putero; Dhani Astuti

    2008-01-01

    State of industry in an area could increase economy of this area. On the other hand, industry may be produce the waste. There are many factor influencing the success of industrial waste management. At present, ISO 14000 is known as an international environmental management standard. Practically, several matter required for ISO 14000 are similar with ISO 9000. So, the role of ISO 9000 certification on supporting waste management program of leather industry has been studied. Study has been pursued by comparing the environmental management systems of 2 leather industries in Sitimulyo, Piyungan, Bantul. Staff working way has been observed to know the suitability with working procedures and implementation of safety aspect on daily working. Observation of waste treatment facility and measurement of Chrome concentration also has been done. Samples were analysed using AAS method in Department of Chemistry, Faculty of Mathematics and Natural Science, Gadjah Mada University. Decontamination Factor (DF) was calculated by comparing the Chrome concentrations on outside plant and in waste treatment facility. Commitment of management and orderliness of system as required on ISO 9000 certification could push the industry to well execute waste management program as a part of environmental management system. ISO 9000 certification is convinced to make awareness of industry grow for continually improving their capability, including their capacity of waste treatment facility. (author)

  7. Nanotechnology Standardization Activities – Support of U.S. Representation on ISO/TC 229 Nanotechnologies

    Energy Technology Data Exchange (ETDEWEB)

    Benko, Heather [American National Standards Inst. (ANSI), Washington, DC (United States)

    2017-03-14

    In carrying out its responsibilities on behalf of the United States, ANSI provides comprehensive, administrative support and expertise on international protocols and procedures to: (1) the U.S. Technical Advisory Group (TAG) to the International Organization for Standardization’s (ISO) Technical Committee (TC) 229 Nanotechnologies, and (2) the corresponding U.S. TAG Working Groups tasked with formulating U.S. positions on topics relevant to nanotechnology standardization. Additionally, secretariat and procedural support is provided for the ISO/TC 229 WG 3 on health, safety and environment, for which the United States was assigned leadership by the participating national body members of ISO/TC 229. As the official entity that serves as the U.S. representative to ISO, ANSI provides not only expert coordination of U.S. positions and representation at ISO but also strategic direction, advice and procedural expertise to facilitate navigation of international issues to promote U.S. positions for incorporation into the ISO/TC 229 program of work necessary to support U.S. objectives.

  8. Blood and urine 8-iso-PGF2α levels in babies of different gestational ages.

    Science.gov (United States)

    Li, Sitao; Hao, Hu; Zhou, Ping; Gao, Ping Ming; Xiao, Xin

    2014-01-01

    We measured cord blood and urine 8-iso-prostaglandin F2α (8-iso-PGF2α) levels in babies of different gestational ages to determine lipid peroxidation status. Babies at gestational ages of 28-43 weeks were divided into group A (28-32 weeks), group B (33-36 weeks), group C (37-41 weeks), and group D (42-43 weeks). 8-iso-PGF2α in umbilical cord blood (UCB) at birth and urine at 6 hours after birth was and tested by ELISA. UCB and urine 8-iso-PGF2α levels in group C were 130.09 ± 31.73 pg/ml and 27.14 ± 6.73 pg/ml, respectively. UCB 8-iso-PGF2α levels in group A and B were 188.42 ± 59.34 pg/ml and 189.37 ± 68.46 pg/ml, and urine 8-iso-PGF2α were 32.14 ± 7.32 pg/ml and 30.46 ± 8.83 pg/ml, respectively. Blood and urine 8-iso-PGF2α levels in group D (post-term) were 252.01 ± 46.42 pg/ml and 44.00 ± 8.50 pg/ml. For all babies, UCB and urine iso-PGF2α levels were significantly correlated (r = 0.65, P iso-PGF2α levels in normal full-term babies. Urine 8-iso-PGF2α levels may reflect the extent of lipid peroxidation in babies. In pre-term and post-term babies, there was evidence for increased lipid peroxidation.

  9. Glucuronidation of deoxynivalenol (DON) by different animal species: identification of iso-DON glucuronides and iso-deepoxy-DON glucuronides as novel DON metabolites in pigs, rats, mice, and cows.

    Science.gov (United States)

    Schwartz-Zimmermann, Heidi E; Hametner, Christian; Nagl, Veronika; Fiby, Iris; Macheiner, Lukas; Winkler, Janine; Dänicke, Sven; Clark, Erica; Pestka, James J; Berthiller, Franz

    2017-12-01

    The Fusarium mycotoxin deoxynivalenol (DON) is a frequent contaminant of cereal-based food and feed. Mammals metabolize DON by conjugation to glucuronic acid (GlcAc), the extent and regioselectivity of which is species-dependent. So far, only DON-3-glucuronide (DON-3-GlcAc) and DON-15-GlcAc have been unequivocally identified as mammalian DON glucuronides, and DON-7-GlcAc has been proposed as further DON metabolite. In the present work, qualitative HPLC-MS/MS analysis of urine samples of animals treated with DON (rats: 2 mg/kg bw, single bolus, gavage; mice: 1 mg/kg bw, single i.p. injection; pigs: 74 µg/kg bw, single bolus, gavage; cows: 5.2 mg DON/kg dry mass, oral for 13 weeks) revealed additional DON and deepoxy-DON (DOM) glucuronides. To elucidate their structures, DON and DOM were incubated with human (HLM) and rat liver microsomes (RLM). Besides the expected DON/DOM-3- and 15-GlcAc, minor amounts of four DON- and four DOM glucuronides were formed. Isolation and enzymatic hydrolysis of four of these compounds yielded iso-DON and iso-DOM, the identities of which were eventually confirmed by NMR. Incubation of iso-DON and iso-DOM with RLM and HLM yielded two main glucuronides for each parent compound, which were isolated and identified as iso-DON/DOM-3-GlcAc and iso-DON/DOM-8-GlcAc by NMR. Iso-DON-3-GlcAc, most likely misidentified as DON-7-GlcAc in the literature, proved to be a major DON metabolite in rats and a minor metabolite in pigs. In addition, iso-DON-8-GlcAc turned out to be one of the major DON metabolites in mice. DOM-3-GlcAc was the dominant DON metabolite in urine of cows and an important DON metabolite in rat urine. Iso-DOM-3-GlcAc was detected in urine of DON-treated rats and cows. Finally, DON-8,15-hemiketal-8-glucuronide, a previously described by-product of DON-3-GlcAc production by RLM, was identified in urine of DON-exposed mice and rats. The discovery of several novel DON-derived glucuronides in animal urine requires adaptation of

  10. Beneficios de la aplicación de normas internacionales ISO en procesos electorales

    Directory of Open Access Journals (Sweden)

    Jeffrey Badí Quinteros Basantes

    2017-01-01

    Full Text Available En este artículo se presentarán los beneficios de la aplicabilidad de las normas internacionales ISO en los procesos electorales, con el fin de poder elevar los niveles de percepción positiva de los ciudadanos. Se verificará la aplicación de normas ISO/TS 17582:2014, Sistemas de Gestión de la Calidad y la norma ISO/IEC 27001:2013, para todas las fases de un proceso electoral. Se expondrán los dominios que forman parte de la norma ISO/TS 17582:2014 , los cuales permiten un proceso de mejoramiento continuo a fin de garantizar la calidad de las metodologías que soportan la organización, administración, gestión, seguimiento y auditorías de un proceso electoral. La norma ISO/IEC 27001:2013 se alinea con la norma ISO9001:2008 para la gestión de seguridad de la información. La aplicación de esta normativa permitirá asegurar la integridad, confidencialidad y disponibilidad de la información durante los procesos electorales.

  11. An iso-erodent map Imo state of Nigeria | Madubuike | International ...

    African Journals Online (AJOL)

    Among inputs/resources often needed for erosion risk assessment of a region is the iso-erodent map of the region. This is a map showing areas of equal erosion potentials in the region. As Imo and Abia states of Nigeria lie in a high erosion region of the country, it was decided in this work to produce an iso-erodent map of ...

  12. Programación de las normas ISO 12217-1 (2011) e ISO 12217-3 (2011) para el estudio de la estabilidad y flotabilidad de embarcaciones de recreo

    OpenAIRE

    Gallardo Martínez, Antonio

    2013-01-01

    Las embarcaciones de recreo para operar dentro de la Comunidad Europea deben de obtener el marcado CE. Para ello se evalúa y clasifica su estabilidad y flotabilidad según la normativa ISO 12217 y se asigna una categoría de diseño (A, B, C o D) adecuada a su diseño y a su carga total máxima. El presente proyecto tiene como objetivo la programación de las normas ISO 12217-1 referente a embarcaciones no propulsadas a vela de eslora igual o superior a 6 m y la norma ISO 12217-3 ...

  13. EPA STANDARDS NETWORK FACT SHEET: ISO 14000: INTERNATIONAL ENVIRONMENTAL MANAGEMENT STANDARDS

    Science.gov (United States)

    This flyer provides an overview of the ISO 14000 series of International standards, supplying a brief history, structure of the Technical Committee (TC) 207, structure of the U.S. Technical Advisory Group (TAG) to ISO TC-207, status of the Standards development as of June 1997, w...

  14. Transgenic Brassica rapa plants over-expressing eIF(iso)4E variants show broad-spectrum Turnip mosaic virus (TuMV) resistance.

    Science.gov (United States)

    Kim, Jinhee; Kang, Won-Hee; Hwang, Jeena; Yang, Hee-Bum; Dosun, Kim; Oh, Chang-Sik; Kang, Byoung-Cheorl

    2014-08-01

    The protein-protein interaction between VPg (viral protein genome-linked) of potyviruses and eIF4E (eukaryotic initiation factor 4E) or eIF(iso)4E of their host plants is a critical step in determining viral virulence. In this study, we evaluated the approach of engineering broad-spectrum resistance in Chinese cabbage (Brassica rapa) to Turnip mosaic virus (TuMV), which is one of the most important potyviruses, by a systematic knowledge-based approach to interrupt the interaction between TuMV VPg and B. rapa eIF(iso)4E. The seven amino acids in the cap-binding pocket of eIF(iso)4E were selected on the basis of other previous results and comparison of protein models of cap-binding pockets, and mutated. Yeast two-hybrid assay and co-immunoprecipitation analysis demonstrated that W95L, K150L and W95L/K150E amino acid mutations of B. rapa eIF(iso)4E interrupted its interaction with TuMV VPg. All eIF(iso)4E mutants were able to complement an eIF4E-knockout yeast strain, indicating that the mutated eIF(iso)4E proteins retained their function as a translational initiation factor. To determine whether these mutations could confer resistance, eIF(iso)4E W95L, W95L/K150E and eIF(iso)4E wild-type were over-expressed in a susceptible Chinese cabbage cultivar. Evaluation of the TuMV resistance of T1 and T2 transformants demonstrated that the over-expression of the eIF(iso)4E mutant forms can confer resistance to multiple TuMV strains. These data demonstrate the utility of knowledge-based approaches for the engineering of broad-spectrum resistance in Chinese cabbage. © 2014 BSPP AND JOHN WILEY & SONS LTD.

  15. Inheritance rules for Hierarchical Metadata Based on ISO 19115

    Science.gov (United States)

    Zabala, A.; Masó, J.; Pons, X.

    2012-04-01

    Mainly, ISO19115 has been used to describe metadata for datasets and services. Furthermore, ISO19115 standard (as well as the new draft ISO19115-1) includes a conceptual model that allows to describe metadata at different levels of granularity structured in hierarchical levels, both in aggregated resources such as particularly series, datasets, and also in more disaggregated resources such as types of entities (feature type), types of attributes (attribute type), entities (feature instances) and attributes (attribute instances). In theory, to apply a complete metadata structure to all hierarchical levels of metadata, from the whole series to an individual feature attributes, is possible, but to store all metadata at all levels is completely impractical. An inheritance mechanism is needed to store each metadata and quality information at the optimum hierarchical level and to allow an ease and efficient documentation of metadata in both an Earth observation scenario such as a multi-satellite mission multiband imagery, as well as in a complex vector topographical map that includes several feature types separated in layers (e.g. administrative limits, contour lines, edification polygons, road lines, etc). Moreover, and due to the traditional split of maps in tiles due to map handling at detailed scales or due to the satellite characteristics, each of the previous thematic layers (e.g. 1:5000 roads for a country) or band (Landsat-5 TM cover of the Earth) are tiled on several parts (sheets or scenes respectively). According to hierarchy in ISO 19115, the definition of general metadata can be supplemented by spatially specific metadata that, when required, either inherits or overrides the general case (G.1.3). Annex H of this standard states that only metadata exceptions are defined at lower levels, so it is not necessary to generate the full registry of metadata for each level but to link particular values to the general value that they inherit. Conceptually the metadata

  16. A Knowledge Organization System for the Development of an ISO 19152:2012 LADM Valuation Module

    NARCIS (Netherlands)

    Çağdaş, Volkan; Kara, A.; Işıkdağ, Ümit; van Oosterom, P.J.M.; Lemmen, Christiaan; Stubkjær, Erik; Halme, Pekka

    2017-01-01

    The challenge to develop interactive information services for new domains is supported by Knowledge Organization Systems and Services (KOS), which model the underlying semantic structure of a domain through classification systems, thesauri, gazetteers, or ontologies. The ISO 19152:2012 Land

  17. Charging of mobile services by mobile payment reference model

    OpenAIRE

    Pousttchi, Key; Wiedemann, Dietmar Georg

    2005-01-01

    The purpose of the paper is to analyze mobile payments in the mobile commerce scenario. Therefore, we first classify the mobile payment in the mobile commerce scenario by explaining general offer models, charging concepts, and intermediaries. Second, we describe the mobile payment reference model, especially, the mobile payment reference organization model and different mobile payment standard types. Finally, we conclude our findings.

  18. Providing for transmission in times of scarcity: an ISO cannot do it all

    International Nuclear Information System (INIS)

    Allen, E.; Ilic, M.; Younes, Z.

    1999-01-01

    The main purpose of this paper is to point out issues critical for establishing a good transmission strategy in an energy market. First, it is suggested that a transmission strategy must be discussed in the context of a specific market structure. Responsibilities of a transmission system provider differ fundamentally, depending on the type of energy market it is supposed to serve. To show this, a summary of information assumed to be known to an Independent System Operator (ISO) in three energy market structures is given, i.e., (1) a mandatory ISO, (2) an entirely multilateral market and (3) a voluntary ISO. The differences between these three proposals concerning an ISO's responsibility for achieving systemwide efficiency and fair charges for transmission service, particularly at times of scarcity, are analyzed. It is shown that an ISO equipped with the present types of optimization tools for both reliability and efficiency is generally 'blind' to questions of fairness with respect to the individual market participants when providing transmission system support. In order to get around this problem, much more work will have to he done by the technical and regulatory communities. The only tools at an ISO's disposal at present are used for systemwide objectives, such as systemwide reliability. While some of this work is under way, it will take some time to develop the actual ISO tools necessary for implementing the fairness criterion metrics ('standards'), whichever ones the community arrives at. (Developing metrics of fair reliability contributions for the individual market participants is a nonunique process, and it may be very difficult to actually agree upon). Meanwhile, in order to have an ISO actively help energy markets in a fair and efficient way in realistic markets, which are likely to be voluntary ISOs, a system user must become an active part of decision making, indicating how much it wishes to use the system at times of scarcity and at which price. One

  19. ISO-PC Version 1.98: User`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Rittmann, P.D.

    1995-05-02

    This document describes how to use Version 1.98 of the shielding program named ISO-PC. Version 1.98 corrects all known errors in ISOSHLD-II. In addition, a few numeric problems have been eliminated. There are three new namelist variables, 25 additional shielding materials, and 5 more energy groups. The two major differences with the original ISOSHLD-II are the removal of RIBD(radioisotope buildup and decay) source generator, and the removal of the non-uniform source distribution parameter, SSV1. This version of ISO-PC works with photon energies from 10 KeV to 10 MeV using 30 energy groups.

  20. The 3D Reference Earth Model: Status and Preliminary Results

    Science.gov (United States)

    Moulik, P.; Lekic, V.; Romanowicz, B. A.

    2017-12-01

    In the 20th century, seismologists constructed models of how average physical properties (e.g. density, rigidity, compressibility, anisotropy) vary with depth in the Earth's interior. These one-dimensional (1D) reference Earth models (e.g. PREM) have proven indispensable in earthquake location, imaging of interior structure, understanding material properties under extreme conditions, and as a reference in other fields, such as particle physics and astronomy. Over the past three decades, new datasets motivated more sophisticated efforts that yielded models of how properties vary both laterally and with depth in the Earth's interior. Though these three-dimensional (3D) models exhibit compelling similarities at large scales, differences in the methodology, representation of structure, and dataset upon which they are based, have prevented the creation of 3D community reference models. As part of the REM-3D project, we are compiling and reconciling reference seismic datasets of body wave travel-time measurements, fundamental mode and overtone surface wave dispersion measurements, and normal mode frequencies and splitting functions. These reference datasets are being inverted for a long-wavelength, 3D reference Earth model that describes the robust long-wavelength features of mantle heterogeneity. As a community reference model with fully quantified uncertainties and tradeoffs and an associated publically available dataset, REM-3D will facilitate Earth imaging studies, earthquake characterization, inferences on temperature and composition in the deep interior, and be of improved utility to emerging scientific endeavors, such as neutrino geoscience. Here, we summarize progress made in the construction of the reference long period dataset and present a preliminary version of REM-3D in the upper-mantle. In order to determine the level of detail warranted for inclusion in REM-3D, we analyze the spectrum of discrepancies between models inverted with different subsets of the

  1. Comparative advantage: the impact of ISO 14001 environmental certification on exports.

    Science.gov (United States)

    Bellesi, Florencia; Lehrer, David; Tal, Alon

    2005-04-01

    Relative to the enormous acceptance of the ISO 9000 quality standard, the ISO 14001 environmental management certification has been met with only moderate enthusiasm among industrial facilities. The literature on corporate motivation for ISO 14001 participation is relatively modest considering the enormous number of publications reviewing other aspects of its adoption and implementation. It would seem that the present "marketing" package supporting ISO environmental commitments does not seem to offer sufficiently persuasive incentives for increased sales, either domestically or internationally. While researchers assume that a higher export rate of companies is positively associated with higher ISO participation rates, there have been very few empirical studies that support this inference, and conclusions have not been based on data taken from importing countries orfrom a systematic evaluation of expressed corporate preference for products sold by ISO 14001 certified companies. The present study reports the results of a survey to firms in six countries that are Israel's leading trade partners, importing chemicals, textiles, and produce. The survey results confirm that while the international market still considers price and quality as the paramount factors in selection of suppliers, environmental management systems (EMS) are an important feature that is frequently taken into consideration. EMS certification appears to signify a supplier who is managing the business well and exhibiting ethical responsibility. The European market proved to be more environmentally conscious than those in other industrialized parts of the world. EMS offer a particularly valuable advantage for producers wishing to reach European markets. As policy-makers seek to expand the voluntary adoption of EMS, a clear advantage for exporters should be highlighted among national industries.

  2. Use of an excess variance approach for the certification of reference materials by interlaboratory comparison

    International Nuclear Information System (INIS)

    Crozet, M.; Rigaux, C.; Roudil, D.; Tuffery, B.; Ruas, A.; Desenfant, M.

    2014-01-01

    In the nuclear field, the accuracy and comparability of analytical results are crucial to insure correct accountancy, good process control and safe operational conditions. All of these require reliable measurements based on reference materials whose certified values must be obtained by robust metrological approaches according to the requirements of ISO guides 34 and 35. The data processing of the characterization step is one of the key steps of a reference material production process. Among several methods, the use of interlaboratory comparison results for reference material certification is very common. The DerSimonian and Laird excess variance approach, described and implemented in this paper, is a simple and efficient method for the data processing of interlaboratory comparison results for reference material certification. By taking into account not only the laboratory uncertainties but also the spread of the individual results into the calculation of the weighted mean, this approach minimizes the risk to get biased certified values in the case where one or several laboratories either underestimate their measurement uncertainties or do not identify all measurement biases. This statistical method has been applied to a new CETAMA plutonium reference material certified by interlaboratory comparison and has been compared to the classical weighted mean approach described in ISO Guide 35. This paper shows the benefits of using an 'excess variance' approach for the certification of reference material by interlaboratory comparison. (authors)

  3. Auto-Ignition of Iso-Stoichiometric Blends of Gasoline-Ethanol-Methanol (GEM) in SI, HCCI and CI Combustion Modes

    KAUST Repository

    Waqas, Muhammad

    2017-03-28

    Gasoline-ethanol-methanol (GEM) blends, with constant stoichiometric air-to-fuel ratio (iso-stoichiometric blending rule) and equivalent to binary gasoline-ethanol blends (E2, E5, E10 and E15 in % vol.), were defined to investigate the effect of methanol and combined mixtures of ethanol and methanol when blended with three FACE (Fuels for Advanced Combustion Engines) Gasolines, I, J and A corresponding to RON 70.2, 73.8 and 83.9, respectively, and their corresponding Primary Reference Fuels (PRFs). A Cooperative Fuel Research (CFR) engine was used under Spark Ignition and Homogeneous Charge Compression Ignited modes. An ignition quality tester was utilized in the Compression Ignition mode. One of the promising properties of GEM blends, which are derived using the iso-stoichiometric blending rule, is that they maintain a constant octane number, which has led to the introduction of methanol as a drop-in fuel to supplement bio-derived ethanol. A constant RON/HCCI fuel number/derived Research octane number property was observed in all three combustion modes for high RON fuels, but for low RON fuels, the iso-stoichiometric blending rule for constant octane number did not appear to be valid. The chemical composition and octane number of the base fuel also influenced the behavior of the GEM blends under different conditions.

  4. Auto-Ignition of Iso-Stoichiometric Blends of Gasoline-Ethanol-Methanol (GEM) in SI, HCCI and CI Combustion Modes

    KAUST Repository

    Waqas, Muhammad; Naser, Nimal; Sarathy, Mani; Feijs, Jeroen; Morganti, Kai; Nyrenstedt, Gustav; Johansson, Bengt

    2017-01-01

    Gasoline-ethanol-methanol (GEM) blends, with constant stoichiometric air-to-fuel ratio (iso-stoichiometric blending rule) and equivalent to binary gasoline-ethanol blends (E2, E5, E10 and E15 in % vol.), were defined to investigate the effect of methanol and combined mixtures of ethanol and methanol when blended with three FACE (Fuels for Advanced Combustion Engines) Gasolines, I, J and A corresponding to RON 70.2, 73.8 and 83.9, respectively, and their corresponding Primary Reference Fuels (PRFs). A Cooperative Fuel Research (CFR) engine was used under Spark Ignition and Homogeneous Charge Compression Ignited modes. An ignition quality tester was utilized in the Compression Ignition mode. One of the promising properties of GEM blends, which are derived using the iso-stoichiometric blending rule, is that they maintain a constant octane number, which has led to the introduction of methanol as a drop-in fuel to supplement bio-derived ethanol. A constant RON/HCCI fuel number/derived Research octane number property was observed in all three combustion modes for high RON fuels, but for low RON fuels, the iso-stoichiometric blending rule for constant octane number did not appear to be valid. The chemical composition and octane number of the base fuel also influenced the behavior of the GEM blends under different conditions.

  5. Organizational leadership: A study on the affects of certification to International Organization for Standardization (ISO)

    Science.gov (United States)

    Cowart, Jewel S.

    Compliance to requirements of ISO is an important leadership problem for the International Aerospace Quality Group (IAQG) and the Aviation, Space and Defense (AS&D) companies. Furthermore, the IAQG seeks to understand the valuation of ISO/AS9100 requirements (2009), audit practices, management functions, business performance, customer satisfaction, and potential future concepts for the standard to assure quality. Since the release of the AS9100C total certification growth surpassed 1,100,000 organizations in 2010 with ISO 9001 series adoption and implementation governing business operations (ASQ, 2012b; ISO, 2011; Bernardo, Llach, & Marimon, 2011). Historians such as Crosby, Juran, Deming, and others established the foundation for quality assurance. Several researchers explored the issues which complicate overall benefits of ISO certification (Iwaro & Mwasha, 2012; Karthi et al., 2012; Sampaio et al., 2009). This study examined the effects on AS&D industries from ISO compliance to identify the implications (of ever-changing requirements) through an online survey of 15,000 practitioners. The research illuminated how ISO affects AS&D industries with current and future requirements for certification. The data showed that 75% of survey respondents report implementation of the AS9100C requirements still has benefits that outweigh the cost. Findings suggest that AS&D industries perceive significant value in the AS9100C document as part of the overall ISO 9000 series. In general, the comments from the survey can provide insight into the affects of ISO certification. The study concludes by recommending continued research to learn of further impacts from ISO certification within AS&D industries to improve the AS9100 document requirements for quality management systems.

  6. ISO 15189 Accreditation: Navigation Between Quality Management and Patient Safety

    Directory of Open Access Journals (Sweden)

    Plebani Mario

    2017-09-01

    Full Text Available Accreditation is a valuable resource for clinical laboratories and the development of an International Standard for their accreditation represented a milestone on the path towards improved quality and safety in laboratory medicine. The recent revision of the International Standard, ISO 15189, has further strengthened its value not only for improving the quality system of a clinical laboratory but also for better answering the request for competence, focus on customers’ needs and ultimate value of laboratory services. Although in some countries more general standards such as ISO 9001 for quality systems or ISO 17025 for testing laboratories are still used, there is increasing recognition of the value of ISO 15189 as the most appropriate and useful standard for the accreditation of medical laboratories. In fact, only this International Standard recognizes the importance of all steps of the total testing process, namely extra-analytical phases, the need to focus on technical competence in addition to quality systems, and the focus on customers’ needs. However, the number of accredited laboratories largely varies between European countries and also major differences affect the approaches to accreditation promoted by the national bodies. In particular, some national accreditation bodies perpetuate the use of fixed scopes, while the European co-operation for accreditation (EA and the European Federation of Laboratory Medicine (EFLM Working Group promote the use of flexible scopes. Major issues in clinical laboratory accreditation are the verification of examination procedures for imprecision, trueness and diagnostic accuracy and for estimating measurement uncertainty. In addition, quality indicators (QIs are a fundamental requirement of the ISO 15189 International Standard.

  7. Incorporating an ISO 8583-Service into an Unreliable Application

    OpenAIRE

    Funcke, Alexander

    2008-01-01

    If an existing service is to be made available to a broader audience, via for instance the Internet. The implementation of the service may thereby get many new requirements, such as support for a different access method or stricter authorisation and security policies. This thesis discusses the implementation of an ISO 8583 to XML proxy. ISO 8583 is a widely used financial protocol, and was in this project used to communicate with the backing financial server in order to implement a complete w...

  8. Approaches to the ISO/IEC 17025 accreditation for Pu and U accountancy analysis

    International Nuclear Information System (INIS)

    Okazaki, Hiro; Sumi, Mika; Abe, Katsuo; Sato, Mitsuhiro; Kageyama, Tomio

    2013-01-01

    The quality control section of Plutonium Fuel Development Center (PFDC) of Japan Atomic Energy Agency has been analyzing isotopic compositions by Mass Spectrometry as well as content by Isotope Dilution Mass Spectrometry (IDMS) of plutonium and uranium in nuclear materials. Along with establishing and managing the quality assurance system, ensuring the reliability of the analysis data is important. PFDC has been establishing the quality management system with ISO9001. ISO9001 consists of management requirements for quality system of organizations. While ISO/IEC 17025 consists of technical requirements for the competence of testing and calibration laboratories in addition to the management requirements. The quality control section addressed technical improvement to improve further reliability of analysis quality and we have accredited for ISO/IEC 17025 of isotopic compositions and content of plutonium and uranium in nuclear materials in March 2010. In this presentation, we report our approaches to the ISO/IEC 17025 accreditation and operation status. (author)

  9. Incorporating ISO Metadata Using HDF Product Designer

    Science.gov (United States)

    Jelenak, Aleksandar; Kozimor, John; Habermann, Ted

    2016-01-01

    The need to store in HDF5 files increasing amounts of metadata of various complexity is greatly overcoming the capabilities of the Earth science metadata conventions currently in use. Data producers until now did not have much choice but to come up with ad hoc solutions to this challenge. Such solutions, in turn, pose a wide range of issues for data managers, distributors, and, ultimately, data users. The HDF Group is experimenting on a novel approach of using ISO 19115 metadata objects as a catch-all container for all the metadata that cannot be fitted into the current Earth science data conventions. This presentation will showcase how the HDF Product Designer software can be utilized to help data producers include various ISO metadata objects in their products.

  10. A Structured Approach for Reviewing Architecture Documentation

    Science.gov (United States)

    2009-12-01

    as those found in ISO 12207 [ ISO /IEC 12207 :2008] (for software engineering), ISO 15288 [ ISO /IEC 15288:2008] (for systems engineering), the Rational...Open Distributed Processing - Reference Model: Foundations ( ISO /IEC 10746-2). 1996. [ ISO /IEC 12207 :2008] International Organization for...Standardization & International Electrotechnical Commission. Sys- tems and software engineering – Software life cycle processes ( ISO /IEC 12207 ). 2008. [ ISO

  11. Modelling air quality according to INSPIRE data specifications, ISO standards and national regulations

    Directory of Open Access Journals (Sweden)

    Pachelski Wojciech

    2017-12-01

    Full Text Available Protection of the environment is an activity of many institutions, organizations and communities from global to regional and local scales. Any activity in this area needs structured database records, using advanced methodology, given, among others, in INSPIRE documents, ISO standards of 19100 series, and national regulations. The goal of this paper is to analyse both the legal provisions related to the air quality and also data sources associated with the prevention of air pollution. Furthermore, the UML application schema of the spatial data related to the air protection is proposed, for the use by urban planners. Also, the overview of the methodology of geographic information is given, including the Unified Modelling Language (UML, as well as the basic concepts of conceptual models within the INSPIRE project. The study is based on the relevant literature and documents, as well as on the expert knowledge gained through urban planning practice, as well as on the analysis of the spatial planning regulations. The UML application schema for different aspects related to the air protection, as presented in this paper, is an example of how to use the methodology also in other fields of the environment protection. Spatial planners know how to improve the air quality, but in the present state of law they often suffer from the lack of planning tools for real actions. In the spatial planners work an important issue are data that allow a thorough analysis of the area.

  12. Requirements for data integration platforms in biomedical research networks: a reference model.

    Science.gov (United States)

    Ganzinger, Matthias; Knaup, Petra

    2015-01-01

    Biomedical research networks need to integrate research data among their members and with external partners. To support such data sharing activities, an adequate information technology infrastructure is necessary. To facilitate the establishment of such an infrastructure, we developed a reference model for the requirements. The reference model consists of five reference goals and 15 reference requirements. Using the Unified Modeling Language, the goals and requirements are set into relation to each other. In addition, all goals and requirements are described textually in tables. This reference model can be used by research networks as a basis for a resource efficient acquisition of their project specific requirements. Furthermore, a concrete instance of the reference model is described for a research network on liver cancer. The reference model is transferred into a requirements model of the specific network. Based on this concrete requirements model, a service-oriented information technology architecture is derived and also described in this paper.

  13. Integration of distributed plant lifecycle data using ISO 15926 and Web services

    International Nuclear Information System (INIS)

    Kim, Byung Chul; Teijgeler, Hans; Mun, Duhwan; Han, Soonhung

    2011-01-01

    Highlights: → The ISO 15926 parts that provide implementation methods are under development. → A prototype of an ISO 15926-based data repository called a facade was implemented. → The prototype facade has the advantages of data interoperability and integration. → These are obtained through the features of ISO 15926 and Web services. - Abstract: Considering the financial, safety, and environmental risks related to industrial installations, it is of paramount importance that all relevant lifecycle information is readily available. Parts of this lifecycle information are stored in a plethora of computer systems, often scattered around the world and in many native formats and languages. These parts can create a complete, holistic set of lifecycle data only when they are integrated together. At present, no software is available that can integrate these parts into one coherent, distributed, and up-to-date set. The ISO 15926 standard has been developed, and in part is still under development, to overcome this problem. In this paper, the authors discuss a prototype of an ISO 15926-based data repository called a facade, and its Web services are implemented for storing the equipment data of a nuclear power plant and servicing the data to interested organizations. This prototype is for a proof-of-concept study regarding the ISO 15926 parts that are currently under development and that are expected to provide implementation methods for the integration of distributed plant systems.

  14. ISOE: an international occupational exposure database and communications network for dose optimisation

    International Nuclear Information System (INIS)

    Robinson, I.F.; Lazo, E.

    1995-01-01

    The Information System on Occupational Exposure (ISOE) was launched by the Nuclear Energy Agency (NEA) of the Organisation for Economic Co-operation and Development (OECD) on 1 January 1992 to facilitate the communication of dosimetry and ALARA implementation data among nuclear facilities around the world. Members of ISOE include 51 utilities from 17 countries and regulators from 11 countries, with four regional technical centres administering the system and a Steering Group which manages the work. ISOE includes three databases and a communications network at several levels. The three databases NEA1, NEA2 and NEA3 include varying levels of details, with NEA3 being the most detailed giving task and site specific ALARA practices and experiences. Utility membership of ISOE gives full access to the databases whereas regulators have more limited access. This paper reviews the current status of participation, describes the three databases and the communications network. Some dose data showing trends in particular countries are presented as well as dose data relating to operation cycle length and outage length. The advantages of membership are described, and it is concluded that ISOE holds the potential for both dose and cost savings. (author)

  15. Anticipated financial effects from the implementation of the standards from the series ISO 9000

    International Nuclear Information System (INIS)

    Dimitrovski, Aleksandar

    1999-01-01

    In the field of quality and the application of the series ISO 9000, in the last decade lot of has been done referring to the implementation, education and documentation of the system quality. In this work a significant effort is given to recognize the connection between material costs and financial effects. I consider that in our area of leaving a little significance is still given to the quality costs, or maybe clearly said, the costs that are made due to bed quality, although it is known that the one of the basic aim of the implementation of the quality system is profit raising. (Original)

  16. As Escalas Geográficas da Certificação ISO 14001: um panorama da gestão ambiental empresarial

    Directory of Open Access Journals (Sweden)

    Henrique Elias Pessoa Gutierres

    2013-06-01

    Full Text Available Environmental certification, especially ISO 14001, demonstrates the existence of internal and external factors for improving the environmental performance of companies. Thus, this article aims to present a current overview of ISO 14001 certification at different scales of analysis (global, national, regional and state, seeking its territoriality by considering factors of location, extent and connection. The following procedures were adopted: a survey of the theoretical reference, the acquisition of data from the ISO (International Organization for Standardization and INMETRO (National Institute of Metrology, Standardization and Industrial Quality on the quantity of companies certified by ISO 14001. After organizing the data, there was systematization through tables via spreadsheet, presentation and finalization of graphs and data analysis relating to the Human Development Index (HDI and Gross Domestic Product (GDP. It is understood that most of these certificates is concentrated in developed countries, where the headquarters of large companies are located. Considering the Brazilian reality, the ratio (number of certifications, GDP and HDI by state was not so obvious, since there are states with lower GDP and HDI, but with higher certificates compared to some states that are better positioned socio-economically. This feature has to do with economic aspects of the companies that have a strong influence on the occurrence of these certificates. Therefore, we present a spatially uneven reality where the environmental certification is not always related to the local reality, being a requirement of external factors, such as a continuing relation with customers and suppliers who hold environmental certification. Therefore, it is something external acting in local reality.

  17. A reference model for model-based design of critical infrastructure protection systems

    Science.gov (United States)

    Shin, Young Don; Park, Cheol Young; Lee, Jae-Chon

    2015-05-01

    Today's war field environment is getting versatile as the activities of unconventional wars such as terrorist attacks and cyber-attacks have noticeably increased lately. The damage caused by such unconventional wars has also turned out to be serious particularly if targets are critical infrastructures that are constructed in support of banking and finance, transportation, power, information and communication, government, and so on. The critical infrastructures are usually interconnected to each other and thus are very vulnerable to attack. As such, to ensure the security of critical infrastructures is very important and thus the concept of critical infrastructure protection (CIP) has come. The program to realize the CIP at national level becomes the form of statute in each country. On the other hand, it is also needed to protect each individual critical infrastructure. The objective of this paper is to study on an effort to do so, which can be called the CIP system (CIPS). There could be a variety of ways to design CIPS's. Instead of considering the design of each individual CIPS, a reference model-based approach is taken in this paper. The reference model represents the design of all the CIPS's that have many design elements in common. In addition, the development of the reference model is also carried out using a variety of model diagrams. The modeling language used therein is the systems modeling language (SysML), which was developed and is managed by Object Management Group (OMG) and a de facto standard. Using SysML, the structure and operational concept of the reference model are designed to fulfil the goal of CIPS's, resulting in the block definition and activity diagrams. As a case study, the operational scenario of the nuclear power plant while being attacked by terrorists is studied using the reference model. The effectiveness of the results is also analyzed using multiple analysis models. It is thus expected that the approach taken here has some merits

  18. ISO: international standards development for nuclear technology

    International Nuclear Information System (INIS)

    Becker, K.

    1981-01-01

    The importance of internationally recognized standards for nuclear technology and safety is rapidly increasing for technical as well as economical and political reasons such as public acceptance and nuclear technology transfer to developing countries. The need for such standards is also evident because of the large number of nuclear installations sited close to international borders, and the export of nuclear installations from relatively few supplier countries to a large number of user countries. It is the purpose of this report to describe briefly the history, organizational structures and procedures, goals, accomplishments, problems, and future needs of the relevant activities of the International Organization for Standardization (ISO). ISO is composed of the partly governmental, partly non-governmental national standards bodies of 86 countries including China. The work of its Technical Committee (TC) 85 'Nuclear Energy' is mostly concerned with industrial applications, contractual aspects and international communication, for the benefit of both developed and developing countries. It works in close liaison with IAEA, which develops Codes and Guides addressed mainly to the regulatory aspects of nuclear power plants in developing countries. ISO/TC 85 has four sub-committees dealing with: (a) Terminology, Definitions, Units and Symbols (Secretariat USA, four working groups (WGs)); (b) Radiation Protection (Secretariat France, ten WGs); (c) Power Reactor Technology (Secretariat Sweden, nine WGs); (d) Nuclear Fuel Technology (Secretariat F.R. Germany, seven WGs). (author)

  19. Reference neutron radiations. Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field

    International Nuclear Information System (INIS)

    2000-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 2. of ISO 8529 takes as its starting point the neutron sources described in ISO 8529-1. It specifies the procedures to be used for realizing the calibration conditions of radiation protection devices in neutron fields produced by these calibration sources, with particular emphasis on the corrections for extraneous effects (e.g., the neutrons scattered from the walls of the calibration room). In this part of ISO 8529, particular emphasis is placed on calibrations using radionuclide sources (clauses 4 to 6) due to their widespread application, with less details given on the use of accelerator and reactor sources (8.2 and 8.3). This part of ISO 8529 then leads to ISO 8529-3 which gives conversion coefficients and the general rules and procedures for calibration

  20. ISO training program mixes lectures, hands-on exercises

    International Nuclear Information System (INIS)

    Sakofsky, S.; Vitale, D.

    1994-01-01

    Early in 1990, the Dresser-Rand Co., made the decision to upgrade its purchased material quality program and pursue ISO 9000 registration for all product divisions. A joint quality-purchasing council from all US based divisions met and developed a new strategy that included: developing and maintaining a common external audit schedule eliminating duplicate audits; development of a formal training program for auditors; implementing a rule for all divisions that called for internal and external audits to be conducted by certified auditors; implementing an aggressive internal audit program for each division preparing for ISO 9001 or 9002 registration. Development of a formal training program began with educating and training future instructors. Two people were selected who had previous audit and quality system experience. Both were sent to various seminars on ISO 9000, attended a lead assessor course, passed the examination, and became registered with the Institute of Quality Assurance (IQA) in the United Kingdom. The original course was developed by a consultant along with one future instructor. Course content used traditional auditing methodology, but included many team exercises including an actual factory audit. The paper describes the methods and contents of this training course

  1. Global Impact Estimation of ISO 50001 Energy Management System for Industrial and Service Sectors

    Energy Technology Data Exchange (ETDEWEB)

    Aghajanzadeh, Arian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Therkelsen, Peter L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McKane, Aimee T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-01

    A methodology has been developed to determine the impacts of ISO 50001 Energy Management System (EnMS) at a region or country level. The impacts of ISO 50001 EnMS include energy, CO2 emissions, and cost savings. This internationally recognized and transparent methodology has been embodied in a user friendly Microsoft Excel® based tool called ISO 50001 Impact Estimator Tool (IET 50001). However, the tool inputs are critical in order to get accurate and defensible results. This report is intended to document the data sources used and assumptions made to calculate the global impact of ISO 50001 EnMS.

  2. Related work on reference modeling for collaborative networks

    NARCIS (Netherlands)

    Afsarmanesh, H.; Camarinha-Matos, L.M.; Camarinha-Matos, L.M.; Afsarmanesh, H.

    2008-01-01

    Several international research and development initiatives have led to development of models for organizations and organization interactions. These models and their approaches constitute a background for development of reference models for collaborative networks. A brief survey of work on modeling

  3. The neuroprotective effects of α-iso-cubebene on dopaminergic cell death: involvement of CREB/Nrf2 signaling.

    Science.gov (United States)

    Park, Sun Young; Son, Beung Gu; Park, Young Hoon; Kim, Cheol-Min; Park, Geuntae; Choi, Young-Whan

    2014-09-01

    As a part of ongoing studies to elucidate pharmacologically active components of Schisandra chinensis, we isolated and studied α-iso-cubebene. The neuroprotective mechanisms of α-iso-cubebene in human neuroblastoma SH-SY5Y cells were investigated. α-Iso-cubebene significantly inhibited cytotoxicity and apoptosis due to 6-hydroxydopamine (6-OHDA)-induced neurotoxicity in dopaminergic SH-SY5Y cells. Pretreatment of cells with α-iso-cubebene reduced intracellular accumulation of ROS and calcium in response to 6-OHDA. The neuroprotective effects of α-iso-cubebene were found to result from protecting the mitochondrial membrane potential. Notably, α-iso-cubebene inhibited the release of apoptosis-inducing factor from the mitochondria into the cytosol and nucleus after 6-OHDA treatment. α-Iso-cubebene also induced the activation of PKA/PKB/CREB/Nrf2 and suppressed 6-OHDA-induced neurotoxicity. α-Iso-cubebene was found to induce phosphorylation of PKA and PKB and activate Nrf2 and CREB signaling pathways in a dose-dependent manner. Additionally, α-iso-cubebene stimulated the expression of the antioxidant response genes NQO1 and HO-1. Finally, α-iso-cubebene-mediated neuroprotective effects were found to be reversible after transfection with CREB and Nrf2 small interfering RNAs.

  4. Reference model analysis of suitability for logistics management

    Directory of Open Access Journals (Sweden)

    Cezary Mańkowski

    2011-12-01

    Full Text Available Reference models are one of the many instruments aspiring to find into a set of different concepts, methods and techniques used in managing the logistics. Therefore, the aim of this paper is to present the results of assessing the suitability of reference models for solving logistical problems. This evaluation indicates that they are universal, support the realization of all the logistics management function in various areas, such as logistics of manufacturing glass products.

  5. Interpretation of MS ISO/ IEC 17020

    International Nuclear Information System (INIS)

    Mohamad Pauzi Ismail

    2012-01-01

    MS ISO/ IEC 17020 is an international standard which adopted by Malaysian Standard states the requirement criteria for inspection bodies. The author involved in the NDT technical assessment to several NDT companies in Malaysia. The experience in performing NDT assessment activity is explained and discussed. (author)

  6. Plasma 8-iso-Prostaglandin F2α concentrations and outcomes after acute intracerebral hemorrhage.

    Science.gov (United States)

    Du, Quan; Yu, Wen-Hua; Dong, Xiao-Qiao; Yang, Ding-Bo; Shen, Yong-Feng; Wang, Hao; Jiang, Li; Du, Yuan-Feng; Zhang, Zu-Yong; Zhu, Qiang; Che, Zhi-Hao; Liu, Qun-Jie

    2014-11-01

    Higher plasma 8-iso-Prostaglandin F2α concentrations have been associated with poor outcome of severe traumatic brain injury. We further investigated the relationships between plasma 8-iso-Prostaglandin F2α concentrations and clinical outcomes in patients with acute intracerebral hemorrhage. Plasma 8-iso-Prostaglandin F2α concentrations of 128 consecutive patients and 128 sex- and gender-matched healthy subjects were measured by enzyme-linked immunosorbent assay. We assessed their relationships with disease severity and clinical outcomes including 1-week mortality, 6-month mortality and unfavorable outcome (modified Rankin Scale score>2). Plasma 8-iso-Prostaglandin F2α concentrations were substantially higher in patients than in healthy controls. Plasma 8-iso-Prostaglandin F2α concentrations were positively associated with National Institutes of Health Stroke Scale (NIHSS) scores and hematoma volume using a multivariate linear regression. It emerged as an independent predictor for clinical outcomes of patients using a forward stepwise logistic regression. ROC curves identified the predictive values of plasma 8-iso-Prostaglandin F2α concentrations, and found its predictive value was similar to NIHSS scores and hematoma volumes. However, it just numerically added the predictive values of NIHSS score and hematoma volume. Increased plasma 8-iso-Prostaglandin F2α concentrations are associated with disease severity and clinical outcome after acute intracerebral hemorrhage. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. The cost of model reference adaptive control - Analysis, experiments, and optimization

    Science.gov (United States)

    Messer, R. S.; Haftka, R. T.; Cudney, H. H.

    1993-01-01

    In this paper the performance of Model Reference Adaptive Control (MRAC) is studied in numerical simulations and verified experimentally with the objective of understanding how differences between the plant and the reference model affect the control effort. MRAC is applied analytically and experimentally to a single degree of freedom system and analytically to a MIMO system with controlled differences between the model and the plant. It is shown that the control effort is sensitive to differences between the plant and the reference model. The effects of increased damping in the reference model are considered, and it is shown that requiring the controller to provide increased damping actually decreases the required control effort when differences between the plant and reference model exist. This result is useful because one of the first attempts to counteract the increased control effort due to differences between the plant and reference model might be to require less damping, however, this would actually increase the control effort. Optimization of weighting matrices is shown to help reduce the increase in required control effort. However, it was found that eventually the optimization resulted in a design that required an extremely high sampling rate for successful realization.

  8. Analysis of reference X radiations energies adjusted for the same half-value layer; Analise do espectro de energias de radiacoes X de referencia ajustadas para a mesma camada semirredutora

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, Marcus Tadeu Tanuri de; Baptista Neto, Annibal Theotonio; Silva, Teogenes Augusto da, E-mail: silvata@cdtn.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Oliveira, Paulo Marcio Campos de [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear

    2011-07-01

    The International Standardization Organization (ISO) defined the reference radiation for calibration and testing in x and gamma fields. The ISO 4037-1 establishes that if the first and the second half value - layers (HVL) agree within 5%, for two x- ray beams, then these two beams shall be considered the same. In this study, reference radiations with the same HVLs that were obtained trough the total filtration or the tube voltage adjustments were compared in terms of spectra and beam parameters. (author)

  9. La gestión en la seguridad de la información según Cobit, Itil e Iso 27000

    Directory of Open Access Journals (Sweden)

    Vladimir Montaño Orrego

    2011-01-01

    Full Text Available Resumen:¿Qué relación tienen Cobit, ITIL e ISO 27000 en la seguridad informática? La experiencia demuestra que resulta algo complicado implementar un Sistema de Gestión de Seguridad de la Información SGSI sin tocar aunque sea tangencialmente este tipo de modelos en los aspectos de seguridad de la información que existe en una Organización.Por ende, usted puede estar implementando su SGSI pudiendo mejorar este sistema mediante la inclusión de áreas de aplicación ISO 27000, o midiendo el estado de maduración de su SGSI a través de Cobit o ITIL.Palabras Clave:ISO (Organización de Estándares Internacionales, ITIL (Biblioteca de Infraestructura de Tecnologías de la Información, OGC (Oficina Gubernamental de Comercio, TI (Tecnologías de la información, COBIT (Objetivos de Control para la Información y Tecnologías relacionadas, IEC (Comisión Internacional de ElectrotecniaAbstract:Is there any relationship between COBIT and ITIL and ISO 27000 about the information security? Experience shows up that is very complex try to implement a “Information Security Management System” ISMS without touch this kind of models in subjects related with information security of the organization.For the time, you may be implementing the ISMS for improving this system through the inclusion of application areas about ISO 27000, or measuring the maturing state of ISMS through COBIT or ITIL.Key Words:ISO, ITIL, OGC, TI, COBIT, IEC.

  10. A study of ISO Solenoid Valve with static and dynamic characteristics

    International Nuclear Information System (INIS)

    Jeon, Y. S.; Ju, M. J.; Oh, Y. C.; Kim, D. S.

    2009-01-01

    The technology of ISO Solenoid Valves is now considered as a core technology in the fields of the production line of semi-conductor chips and the ISO fluid chips for medical applications. And ISO Solenoid Valves, which operate by compressed air, are characterized by high speed response, great repeatability and that the pressure on the cross sectional area of poppet is kept constant regardless of the fluctuation of the pressure exerted on the ports. The primary objective of this study is to compare the optimally designed Solenoid Valve with the actually produced one and to design a power saving circuit which can highly improve the efficiency by providing optimal current according to mechanical load.

  11. ISO 9000 and 10CFR50, appendix B-one, both, or neither?

    International Nuclear Information System (INIS)

    Nau, D.C.; Hunt, G.L.

    1993-01-01

    The evolution of quality system requirements has led to the development of standards that either have been tailored for use in specific industries (as in the case of 10CFR50, Appendix B) or have been made generic for use in commercial operations (as in the case of the ISO 9000 series of standards). The elements of many quality systems are shared to a large degree, and the requirements of the standards only generally differ in certification, training, and documentation requirements. The proof of conformance to the requirements of 10CFR50, Appendix B, and ISO 9001 is in large part identical. Table I provides an example of the quality elements common between 10CFR50, Appendix B, and ISO 9001. Substantive proof that a supplier's qualification system meets the requirements of 10CFR50, Appendix B, can substantially be used as proof of conformance to ISO 9001

  12. ISO 9001 laatujärjestelmän liittäminen osaksi ISM manuaalia

    OpenAIRE

    Koskinen, Ville

    2016-01-01

    Lopputyön aiheena on Turkulaisen varustamon VG-Shipping Oy toimeksiantona selvittää ISO 9001 standardin vaatimusten mukaisten ohjeistuksien liittäminen yrityksen voimassa olevaan turvallisuusjohtamisjärjestelmään (ISM) ja yhdistetyn manuaalin rakentaminen vastaamaan molempien standardien (ISM koodi ja ISO 9001 standardi) vaatimuksia, siten että varustamon alukset eivät ole ISO 9001 luokiteltuja vaan ainoastaan ISM koodin mukaan auditoituja. Lopullisena toimenpiteenä on hyväksyttää ja audit...

  13. [Effects of the ISO 15189 accreditation on Nagoya University Hospital].

    Science.gov (United States)

    Yoshiko, Kenichi

    2012-07-01

    The Department of Clinical Laboratory, Nagoya University Hospital acquired ISO 15189 accreditation in November, 2009. The operation of our Quality Management System (QMS) was first surveyed in October, 2010. In this paper, we reported the activity for the preparation and operation of our QMS and the effects of ISO 15189 accreditation. We investigated the changes in the number and content on nonconformities, incident reports and complaints before and after accreditation as indicators to evaluate the effect of ISO 15189 accreditation. Post accreditation, the number of nonconformities and incident reports decreased, seeming to show an improvement of quality of the laboratory activity; however, the number of complaints increased. We identified the increase of complaints at the phlebotomy station. There had been some problems with blood sampling in the past, but it seemed that staff had a high level of concern regarding these problems at the phlebotomy station and took appropriate measures to resolve the complaints. We confirmed that the ISO 15189 accreditation was instrumental in the improvements of the safety and efficiency on laboratory works. However there was a problem that increase of overtime works to operate the QMS. We deal with development of a laboratory management system using IT recourses to solve the problem.

  14. The role of the IEC and ISO in radiological protection

    International Nuclear Information System (INIS)

    White, D.F.

    1976-01-01

    The history, objectives, structures and functions of the International Electrotechnical Commission (IEC) and the International Organisation for Standardisation (ISO) are summarized. The IEC is affiliated to the ISO as its electrical division, but has technical and financial autonomy. Member countries of the EEC may be committed to the adoption of their formal agreements ('Standards') if these become incorporated as Directives. The national standardisation organisations, such as BSI in the U.K., form national committees and are responsible for submitting to the IEC the co-ordinated national viewpoints on particular subjects. The overall links between the technical committees and sub-committees of the ISO, IEC and BSI in the field of radiological protection are tabulated, and the relevant International Standards produced, or in the course of preparation, by the appropriate committees of the ISO and the IEC are listed. The bulk of the effort of the BSI committees is now aimed at the production of acceptable international standards. Compatible national standards then follow. This policy is in contrast to the earlier initial emphasis on national standards, and the improved international collaboration has had two welcome effects. The selection of proposals for standards is more critical, and compatibility with the relevant ICRP and ICRU publications is almost a prerequisite for any international standard. (U.K.)

  15. Certification centres for management systems in the energy industry. Principles, normative specifications, DAkkS specifications, formalita using the example of ISO 27001; Zertifizierungsstellen fuer Managementsysteme in der Energiewirtschaft. Grundlagen, normative Vorgaben, DAkkS Vorgaben, Formalita am Beispiel ISO 27001

    Energy Technology Data Exchange (ETDEWEB)

    Loubichi, Stefan [rps-training and consulting GmbH, Koeln (Germany)

    2017-11-15

    The IT security law forced the energy industry to implement system certifications for the first time in history. In contrast to most companies in the energy industry, which often only knew about product certifications, the energy industry now has to enter new territory. Certification companies receive their legitimation in Germany through DAkkS. The DAkkS is embedded in the context of European Union law. The work of the certification companies is determined by the specifications of the DAkkS as well as by the requirements of the ISO/IEC standards. These regulations should in any case be known to a certification customer so that he knows what a certification company does or does not do. In addition, a certification customer must also know which evidence must be presented in the sense of a reference standard against the certification company. The concrete evidence in this essay is based on an ISO/IEC 27001 certification in conjunction with the IT Security Catalog of the Bundesnetzagentur. With all this knowledge, the cooperation with the certification company will not be a problem for system certification.

  16. DIFFERENCES IN MANAGER ASSESSMENTS OF ISO 14000 STANDARD IMPLEMENTATION IN TURKEY

    Directory of Open Access Journals (Sweden)

    Sıtkı Gözlü

    2005-12-01

    Full Text Available This study reports the results of a survey about the improvements achieved as result of ISO 14000 Environmental Management System (EMS standard implementation and the differences of improvements with respect to firm characteristics. A survey has been conducted in order to explain the improvements related to environmental management process and overall firm performance. The survey involved sixty-six enterprises implementing ISO 14000 EMS standard in Turkey. In order to assess improvements obtained from ISO 14000 EMS implementation, statements related to environmental management process and overall firm performance indicators have been prepared. The statements in this study are relevant to previous research. A factor analysis was employed to determine the factors of the variables explaining improvements. Nine factors have been identified related to achieved improvements, such as establishment of pro-active environmental management system, effectiveness in resource utilization, effectiveness of process control, relationships with industry and government, meeting expectations of stakeholders, demonstration of social responsibility, profitability, productivity, and competitiveness. Then, a T- test was conducted to determine the differences of managers’ assessments with respect to certain firm characteristics. The findings have shown that there are differences in the assessments of improvements achieved as a result of ISO 14000 EMS standard implementation with respect to sales volume, foreign-capital possession, and ISO 14000 EMS standard implementation. On the other hand, industrial sector, age of establishment, and export orientation are not statistically significant for the differences in the assessments of improvements.

  17. Laboratory accreditation complying with ISO 25 Guide (IRAM 301): Industrial radiography method

    International Nuclear Information System (INIS)

    Schneebeli, Jorge E.; Zampini, Juan J.; Naucevich, Alfredo

    2000-01-01

    The ISO 25 Guide (IRAM 301) replaced by ISO 17025 is the standard applied for the implementation of a quality system in a test or calibration laboratory. This document is not known as ISO 9000, but it is the proper standard for this kind of laboratory. This document establishes requirements no just for the quality system in general, but on technical competence, that means the laboratory technical aptitude to carry out the tests. The aim of this paper is to comment the criteria used in the Radiographic Laboratory of CEMEC, that have been assessed by the United King dome Accreditation Service (UKAS). (author)

  18. Occupational exposures at nuclear power plants. Fourteenth annual report of the ISOE programme, 2004

    International Nuclear Information System (INIS)

    2006-01-01

    The ISOE Programme was created by the OECD Nuclear Energy Agency in 1992 to promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The programme provides experts in occupational radiation protection with a forum for communication and exchange of experience. The ISOE databases enable the analysis of occupational exposure data from 478 operating and shutdown commercial nuclear power plants participating in the programme (representing some 90% of the world's total operating commercial reactors). The Fourteenth Annual Report of the ISOE Programme summarises achievements made during 2004 and compares annual occupational exposure data. Principal developments in ISOE participating countries are also described. (author)

  19. Occupational exposures at nuclear power plants. Eleventh annual report of the Isoe programme, 2001

    International Nuclear Information System (INIS)

    2002-01-01

    The ISOE Programme was created by the OECD Nuclear Energy Agency in 1992 to promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The programme provides experts in occupational radiation protection with a forum for communication and exchange of experience. The ISOE databases enable the analysis of occupational exposure data from the 452 commercial nuclear power plants participating in the programme (representing some 90 per cent of the world's total operating commercial reactors). The Eleventh Annual Report of the ISOE Programme summarises achievements made during 2001 and compares annual occupational exposure data. Principal developments in ISOE participating countries are also described. (author)

  20. Estimating ecosystem iso/anisohydry using microwave satellite data and its applications in ecohydrology

    Science.gov (United States)

    Li, Y.; Guan, K.; Gentine, P.; Konings, A. G.; Bhattacharya, A.; Meinzer, F. C.; Kimball, J. S.; Xu, X.; Anderegg, W.; McDowell, N. G.; Martínez-Vilalta, J.; Long, D. G.; Good, S. P.

    2017-12-01

    The concept of iso/anisohydry describes the degree to which plants regulate their water status, operating from isohydric with strict stomatal closure to anisohydric with greater stomatal conductance under drying conditions. Though some species-level measures of iso/anisohydry exist at limited locations, ecosystem scale information is still largely unavailable. In this study, we use diurnal observations from active (Ku-Band backscatter from QuikSCAT) and passive (X-band Vegetation Optical Depth [VOD] from AMSR-E) microwave satellite data to estimate global ecosystem iso/anisohydry. The two independent estimates from radar backscatter and VOD show good agreement at low and mid-latitudes but diverge at high latitudes. Grasslands, croplands, wetlands, and open shrublands are more anisohydric, whereas evergreen broadleaf and deciduous broadleaf forests are more isohydric. The direct validation with upscaled in-situ species iso/anisohydry estimates indicates that the VOD estimates have much better agreement than the backscatter in terms of their iso/anisohydry metrics. The indirect validation suggests that both estimates are consistent with prior knowledge that vegetation water status of anisohydric ecosystems more closely tracks environmental fluctuations of water availability and demand than their isohydric counterparts. The ecosystem level iso/anisohydry can be applied to reveal new insights into spatio-temporal ecosystem response to droughts. We conducted a case study to demonstrate the potential application of iso/anisohydry. We find that during the 2011 drought in US, over the drought affected region in the southern US, isohydric ecosystems experienced larger decline in productivity (NDVI and GPP) than anisohydric ones. However, during the 2012 drought in central US, both isohydric and anisohydric ecosystems exhibited similar decline in productivity.

  1. Reference datum level

    Digital Repository Service at National Institute of Oceanography (India)

    Pathak, M.C.; Kotnala, K.L.

    stream_size 5 stream_content_type text/plain stream_name Trg_Calculat_Water_Depth_Chart_Datum_1991_25.pdf.txt stream_source_info Trg_Calculat_Water_Depth_Chart_Datum_1991_25.pdf.txt Content-Encoding ISO-8859-1 Content-Type text.../plain; charset=ISO-8859-1 ...

  2. Fast tracking ICT infrastructure requirements and design, based on Enterprise Reference Architecture and matching Reference Models

    DEFF Research Database (Denmark)

    Bernus, Peter; Baltrusch, Rob; Vesterager, Johan

    2002-01-01

    The Globemen Consortium has developed the virtual enterprise reference architecture and methodology (VERAM), based on GERAM and developed reference models for virtual enterprise management and joint mission delivery. The planned virtual enterprise capability includes the areas of sales...

  3. Corporate environmental policy statements in mainland China: to what extent do they conform to ISO 14000 documentation?

    Science.gov (United States)

    Chung, Shan Shan; Fryxell, Gerald E; Lo, Carlos W H

    2005-04-01

    For decades, industry has been the main source of pollution in China. Determined to make changes, the mainland Chinese authorities have decided to promote mechanisms that incorporate environmental concerns into the internal management of enterprises. This is manifested in the rapid adoption of the ISO14000 standards, including a significant increase in ISO14001 registrations in China. Thus, this study examined the environmental policy statements of 106 certified facilities in mainland China against a strict interpretation of the mandatory requirements of the ISO 14001:1996 standard and the nonmandatory ISO14004 requirements in order to shed some light on the implementation of environmental management systems in an emerging economic giant. It was decided to analyze the environmental policy statement because such a statement is a core element in the ISO system of environmental management of each facility and there are relatively clear and specific requirements on what an environmental policy statement shall include. An analysis of the contents of the environmental policy statements shows that conformance to the relevant requirements of both the mandatory ISO14001 standard and the nonmandatory ISO14004 standard is far from impressive and that the facilities in our sample seldom went beyond the minimum requirements. By using ISO14001 and ISO14004 conformance scores as the dependent variables, we found that conformity to ISO14001 and overall conformance to ISO14000 series can be explained to some extent by the degree of top management commitment, the experience with informal environmental management systems, and the form of ownership of the facilities.

  4. Attaining ISO 15189 accreditation through SLMTA: A journey by Kenya’s National HIV Reference Laboratory

    Directory of Open Access Journals (Sweden)

    Thomas Gachuki

    2014-11-01

    Objectives: This study chronicles the journey that NHRL took in pursuit of accreditation, along with the challenges and lessons learned. Methods: NHRL participated in the Strengthening Laboratory Management Toward Accreditation (SLMTA programme from 2010–2011. Improvement projects were undertaken to address gaps in the 12 quality system essentials through development of work plans, team formation, training and mentorship of personnel. Audits were conducted and the scores used to track progress along a five-star grading scale. Standard quality indicators (turn-around time, specimen rejection rates and service interruptions were measured. Costs of improvement projects and accreditation were estimated based on expenditures. Results: NHRL scored 45% (zero stars at baseline in March 2010 and 95% (five stars after programme completion in October 2011; in 2013 it became the first public health laboratory in Kenya to attain ISO 15189 accreditation. From 2010–2013, turn-around times decreased by 50% – 95%, specimen rejections decreased by 93% and service interruptions dropped from 15 to zero days. Laboratory expenditures associated with achieving accreditation were approximately US $36 500. Conclusion: International accreditation is achievable through SLMTA, even for a laboratory with limited initial quality management systems. Key success factors were dedication to a shared goal, leadership commitment, team formation and effective mentorship. Countries wishing to achieve accreditation must ensure adequate funding and support.

  5. OWL references in ORM conceptual modelling

    Science.gov (United States)

    Matula, Jiri; Belunek, Roman; Hunka, Frantisek

    2017-07-01

    Object Role Modelling methodology is the fact-based type of conceptual modelling. The aim of the paper is to emphasize a close connection to OWL documents and its possible mutual cooperation. The definition of entities or domain values is an indispensable part of the conceptual schema design procedure defined by the ORM methodology. Many of these entities are already defined in OWL documents. Therefore, it is not necessary to declare entities again, whereas it is possible to utilize references from OWL documents during modelling of information systems.

  6. Vergelijking van een tijd besparende analysemethode voor hydroxyproline met ISO 3496-1978

    NARCIS (Netherlands)

    Cazemier, G.; Tuinstra, L.G.M.Th.; Werdmuller, G.A.

    1988-01-01

    De bepaling van hydroxyproline volgens de referentiemethode ISO 3496 is zeer tijdrovend. In een door het Nordisk Metodikkomitti för Livsmedel voorgestelde methode is een aantal wijzigingen ten opzichte van ISO 3496 aangebracht die de analysetijd per monster sterk verkorten. Om na te gaan of deze

  7. Selection of References in Wind Turbine Model Predictive Control Design

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Hovgaard, Tobias

    2015-01-01

    a model predictive controller for a wind turbine. One of the important aspects for a tracking control problem is how to setup the optimal reference tracking problem, as it might be relevant to track, e.g., the three concurrent references: optimal pitch angle, optimal rotational speed, and optimal power......Lowering the cost of energy is one of the major focus areas in the wind turbine industry. Recent research has indicated that wind turbine controllers based on model predictive control methods can be useful in obtaining this objective. A number of design considerations have to be made when designing....... The importance if the individual references differ depending in particular on the wind speed. In this paper we investigate the performance of a reference tracking model predictive controller with two different setups of the used optimal reference signals. The controllers are evaluated using an industrial high...

  8. Analysis of the Air Force ISO 14001 Pilot Study Conducted by DoD

    National Research Council Canada - National Science Library

    Harris, Rodney

    2000-01-01

    The Department of Defense (DoD) conducted an ISO 14001 pilot study with the primary goal of determining how ISO 14001 could help DoD organizations reduce risks, improve compliance with environmental regulations, enhance stewardship...

  9. Analisis Sistem Manajemen Keamanan Informasi Menggunakan ISO/IEC 27001 : 2013 Serta Rekomendasi Model Sistem Menggunakan Data Flow Diagram pada Direktorat Sistem Informasi Perguruan Tinggi

    Directory of Open Access Journals (Sweden)

    Yuni Cintia Yuze

    2016-11-01

    Full Text Available The importance of information and the possible risk of disruption, therefore the universities need to designed and implemented of the information security.  One of the standards that can be used to analyze the level of information security in the organization is ISO/IEC 27001 : 2013 and this standard has been prepared to provide requirements for establishing, implementing, maintaining and continually improving an information security management system. The objective of this research is to measure the level of information security based on standard ISO/IEC 27001: 2013 and modeling systems for information security management. This research uses descriptive qualitative approach, data collection and validation techniques with tringulasi (interview, observation and documentation. Data was analyzed using gap analysis and to measure the level of maturity this research uses SSE-CMM (Systems Security Engineering Capability Maturity Model. Based on the research results, Maturity level clause Information Security Policy reaches level 1 (Performed-Informally, clause Asset Management reaches level 3 (Well-Defined, clause Access Control reaches level 3 (Well-Defined, clause Physical and Environmental Security reaches level 3 (Well-Defined, clause Operational Security reaches level 3 (Well-Defined, Communication Security clause reaches the level 2 (Planned and Tracked. Based on the results of maturity level discovery of some weakness in asset management in implementing the policy. Therefore, the modeling system using the flow map and CD / DFD focused on Asset Management System.

  10. Interoperability of medical device information and the clinical applications: an HL7 RMIM based on the ISO/IEEE 11073 DIM.

    Science.gov (United States)

    Yuksel, Mustafa; Dogac, Asuman

    2011-07-01

    Medical devices are essential to the practice of modern healthcare services. Their benefits will increase if clinical software applications can seamlessly acquire the medical device data. The need to represent medical device observations in a format that can be consumable by clinical applications has already been recognized by the industry. Yet, the solutions proposed involve bilateral mappings from the ISO/IEEE 11073 Domain Information Model (DIM) to specific message or document standards. Considering that there are many different types of clinical applications such as the electronic health record and the personal health record systems, the clinical workflows, and the clinical decision support systems each conforming to different standard interfaces, detailing a mapping mechanism for every one of them introduces significant work and, thus, limits the potential health benefits of medical devices. In this paper, to facilitate the interoperability of clinical applications and the medical device data, we use the ISO/IEEE 11073 DIM to derive an HL7 v3 Refined Message Information Model (RMIM) of the medical device domain from the HL7 v3 Reference Information Mode (RIM). This makes it possible to trace the medical device data back to a standard common denominator, that is, HL7 v3 RIM from which all the other medical domains under HL7 v3 are derived. Hence, once the medical device data are obtained in the RMIM format, it can easily be transformed into HL7-based standard interfaces through XML transformations because these interfaces all have their building blocks from the same RIM. To demonstrate this, we provide the mappings from the developed RMIM to some of the widely used HL7 v3-based standard interfaces.

  11. Sensorless adaptive optics for isoSTED nanoscopy

    Science.gov (United States)

    Antonello, Jacopo; Hao, Xiang; Allgeyer, Edward S.; Bewersdorf, Joerg; Rittscher, Jens; Booth, Martin J.

    2018-02-01

    The presence of aberrations is a major concern when using fluorescence microscopy to image deep inside tissue. Aberrations due to refractive index mismatch and heterogeneity of the specimen under investigation cause severe reduction in the amount of fluorescence emission that is collected by the microscope. Furthermore, aberrations adversely affect the resolution, leading to loss of fine detail in the acquired images. These phenomena are particularly troublesome for super-resolution microscopy techniques such as isotropic stimulated-emission-depletion microscopy (isoSTED), which relies on accurate control of the shape and co-alignment of multiple excitation and depletion foci to operate as expected and to achieve the super-resolution effect. Aberrations can be suppressed by implementing sensorless adaptive optics techniques, whereby aberration correction is achieved by maximising a certain image quality metric. In confocal microscopy for example, one can employ the total image brightness as an image quality metric. Aberration correction is subsequently achieved by iteratively changing the settings of a wavefront corrector device until the metric is maximised. This simplistic approach has limited applicability to isoSTED microscopy where, due to the complex interplay between the excitation and depletion foci, maximising the total image brightness can lead to introducing aberrations in the depletion foci. In this work we first consider the effects that different aberration modes have on isoSTED microscopes. We then propose an iterative, wavelet-based aberration correction algorithm and evaluate its benefits.

  12. Functional Suitability Measurement using Goal-Oriented Approach based on ISO/IEC 25010 for Academics Information System

    Directory of Open Access Journals (Sweden)

    Ajeng Savitri Puspaningrum

    2017-10-01

    Full Text Available Rapid of information technology development grow a new competitive environment. Including higher education, they need to improve their service quality in order to provide education service in more competitive. One of the ways of using information technology in higher education is the used of Academic Information System (AIS. AIS was developed to achieve the goals of the learning process which is one of vision and mission organization success factor. The measurement is needed to evaluate the quality of AIS. Functionality is one of the quality factors which is measured by observing the correlation between function and functional suitability. In this study, the quality of AIS functional suitability is measured using goal-oriented approach base on ISO/IEC 25010 in the perspective of a lecturer. The strategic plan of an institution is used as a reference to measure if the system used to have meet institution goals when using this approach. The result shows that the measurement using goal-oriented approach become more objective and suitable to the need of used AIS quality improvement for the institution than the measurement with ISO/IEC 25010 only.

  13. The Impact of ISO Quality Management Systems on Primary and Secondary Schools in Spain

    Science.gov (United States)

    Arribas Díaz, Jorge Antonio; Martínez-Mediano, Catalina

    2018-01-01

    Purpose: The purpose of this study is to evaluate the application of quality management systems (QMS) based on international standards of quality in education (ISO 9001:2008) and ascertain the influence of this quality model on primary and secondary schools in Spain. Design/methodology/approach: The study was conducted in 26 publicly funded,…

  14. Formation of iso-ursodeoxycholic acid during administration of ursodeoxycholic acid in man

    NARCIS (Netherlands)

    Beuers, U.; Fischer, S.; Spengler, U.; Paumgartner, G.

    1991-01-01

    The appearance of iso-ursodeoxycholic acid (isoUDCA; 3 beta,7 beta-dihydroxy-5 beta-cholan-24-oic acid) in serum of patients with chronic cholestatic liver disease and of healthy subjects during administration of ursodeoxycholic acid (UDCA) is reported. Comparison of the mass spectrum of the newly

  15. Occupational heat stress and associated productivity loss estimation using the PHS model (ISO 7933): a case study from workplaces in Chennai, India

    Science.gov (United States)

    Lundgren, Karin; Kuklane, Kalev; Venugopal, Vidhya

    2014-01-01

    Background Heat stress is a major occupational problem in India that can cause adverse health effects and reduce work productivity. This paper explores this problem and its impacts in selected workplaces, including industrial, service, and agricultural sectors in Chennai, India. Design Quantitative measurements of heat stress, workload estimations, and clothing testing, and qualitative information on health impacts, productivity loss, etc., were collected. Heat strain and associated impacts on labour productivity between the seasons were assessed using the International Standard ISO 7933:2004, which applies the Predicted Heat Strain (PHS) model. Results and conclusions All workplaces surveyed had very high heat exposure in the hot season (Wet Bulb Globe Temperature x¯ =29.7), often reaching the international standard safe work values (ISO 7243:1989). Most workers had moderate to high workloads (170–220 W/m2), with some exposed to direct sun. Clothing was found to be problematic, with high insulation values in relation to the heat exposure. Females were found to be more vulnerable because of the extra insulation added from wearing a protective shirt on top of traditional clothing (0.96 clo) while working. When analysing heat strain – in terms of core temperature and dehydration – and associated productivity loss in the PHS model, the parameters showed significant impacts that affected productivity in all workplaces, apart from the laundry facility, especially during the hot season. For example, in the canteen, the core temperature limit of 38°C predicted by the model was reached in only 64 min for women. With the expected increases in temperature due to climate change, additional preventive actions have to be implemented to prevent further productivity losses and adverse health impacts. Overall, this study presented insight into using a thermo-physiological model to estimate productivity loss due to heat exposure in workplaces. This is the first time the PHS

  16. Occupational heat stress and associated productivity loss estimation using the PHS model (ISO 7933): a case study from workplaces in Chennai, India.

    Science.gov (United States)

    Lundgren, Karin; Kuklane, Kalev; Venugopal, Vidhya

    2014-01-01

    Heat stress is a major occupational problem in India that can cause adverse health effects and reduce work productivity. This paper explores this problem and its impacts in selected workplaces, including industrial, service, and agricultural sectors in Chennai, India. Quantitative measurements of heat stress, workload estimations, and clothing testing, and qualitative information on health impacts, productivity loss, etc., were collected. Heat strain and associated impacts on labour productivity between the seasons were assessed using the International Standard ISO 7933:2004, which applies the Predicted Heat Strain (PHS) model. All workplaces surveyed had very high heat exposure in the hot season (Wet Bulb Globe Temperature =29.7), often reaching the international standard safe work values (ISO 7243:1989). Most workers had moderate to high workloads (170-220 W/m2), with some exposed to direct sun. Clothing was found to be problematic, with high insulation values in relation to the heat exposure. Females were found to be more vulnerable because of the extra insulation added from wearing a protective shirt on top of traditional clothing (0.96 clo) while working. When analysing heat strain--in terms of core temperature and dehydration--and associated productivity loss in the PHS model, the parameters showed significant impacts that affected productivity in all workplaces, apart from the laundry facility, especially during the hot season. For example, in the canteen, the core temperature limit of 38°C predicted by the model was reached in only 64 min for women. With the expected increases in temperature due to climate change, additional preventive actions have to be implemented to prevent further productivity losses and adverse health impacts. Overall, this study presented insight into using a thermo-physiological model to estimate productivity loss due to heat exposure in workplaces. This is the first time the PHS model has been used for this purpose. An exploratory

  17. Occupational heat stress and associated productivity loss estimation using the PHS model (ISO 7933: a case study from workplaces in Chennai, India

    Directory of Open Access Journals (Sweden)

    Karin Lundgren

    2014-11-01

    Full Text Available Background: Heat stress is a major occupational problem in India that can cause adverse health effects and reduce work productivity. This paper explores this problem and its impacts in selected workplaces, including industrial, service, and agricultural sectors in Chennai, India. Design: Quantitative measurements of heat stress, workload estimations, and clothing testing, and qualitative information on health impacts, productivity loss, etc., were collected. Heat strain and associated impacts on labour productivity between the seasons were assessed using the International Standard ISO 7933:2004, which applies the Predicted Heat Strain (PHS model. Results and conclusions: All workplaces surveyed had very high heat exposure in the hot season (Wet Bulb Globe Temperature x¯ =29.7, often reaching the international standard safe work values (ISO 7243:1989. Most workers had moderate to high workloads (170–220 W/m2, with some exposed to direct sun. Clothing was found to be problematic, with high insulation values in relation to the heat exposure. Females were found to be more vulnerable because of the extra insulation added from wearing a protective shirt on top of traditional clothing (0.96 clo while working. When analysing heat strain – in terms of core temperature and dehydration – and associated productivity loss in the PHS model, the parameters showed significant impacts that affected productivity in all workplaces, apart from the laundry facility, especially during the hot season. For example, in the canteen, the core temperature limit of 38°C predicted by the model was reached in only 64 min for women. With the expected increases in temperature due to climate change, additional preventive actions have to be implemented to prevent further productivity losses and adverse health impacts. Overall, this study presented insight into using a thermo-physiological model to estimate productivity loss due to heat exposure in workplaces. This is the

  18. Definition of an ISO 19115 metadata profile for SeaDataNet II Cruise Summary Reports and its XML encoding

    Science.gov (United States)

    Boldrini, Enrico; Schaap, Dick M. A.; Nativi, Stefano

    2013-04-01

    SeaDataNet implements a distributed pan-European infrastructure for Ocean and Marine Data Management whose nodes are maintained by 40 national oceanographic and marine data centers from 35 countries riparian to all European seas. A unique portal makes possible distributed discovery, visualization and access of the available sea data across all the member nodes. Geographic metadata play an important role in such an infrastructure, enabling an efficient documentation and discovery of the resources of interest. In particular: - Common Data Index (CDI) metadata describe the sea datasets, including identification information (e.g. product title, interested area), evaluation information (e.g. data resolution, constraints) and distribution information (e.g. download endpoint, download protocol); - Cruise Summary Reports (CSR) metadata describe cruises and field experiments at sea, including identification information (e.g. cruise title, name of the ship), acquisition information (e.g. utilized instruments, number of samples taken) In the context of the second phase of SeaDataNet (SeaDataNet 2 EU FP7 project, grant agreement 283607, started on October 1st, 2011 for a duration of 4 years) a major target is the setting, adoption and promotion of common international standards, to the benefit of outreach and interoperability with the international initiatives and communities (e.g. OGC, INSPIRE, GEOSS, …). A standardization effort conducted by CNR with the support of MARIS, IFREMER, STFC, BODC and ENEA has led to the creation of a ISO 19115 metadata profile of CDI and its XML encoding based on ISO 19139. The CDI profile is now in its stable version and it's being implemented and adopted by the SeaDataNet community tools and software. The effort has then continued to produce an ISO based metadata model and its XML encoding also for CSR. The metadata elements included in the CSR profile belong to different models: - ISO 19115: E.g. cruise identification information, including

  19. Handbook on Life Cycle Assessment. Operational Guide to the ISO Standards

    Energy Technology Data Exchange (ETDEWEB)

    Guinee, J.B. [Centre of Environmental Studies, Leiden University, Leiden (Netherlands)

    2002-04-01

    In 1992 the Centre of Environmental Science (CML) at Leiden University, The Netherlands, published a Guide on Environmental Life Cycle Assessment (LCA) methodology, setting the standard for a long time. Since then LCA methodology has progressed enormously and the International Organization for Standardization (ISO) has published a series of Standards on LCA. These developments have now been incorporated into a new Handbook on LCA authored by CML in cooperation with a number of other important institutes in the area of LCA. The general aim of this Handbook on LCA is to provide a stepwise 'cookbook' with operational guidelines for conducting an LCA study step-by-step, justified by a scientific background document, based on the ISO Standards for LCA. The different ISO elements and requirements are made operational to the 'best available practice' for each step. CML is strongly involved in the development of a standard methodology to determine environmental impacts of products, i.e., LCA. This is done within international fora such as the Society for Environmental Toxicology and Chemistry (SETAC), the International Organization for Standardization (ISO), and the United Nations Environmental Programme (UNEP)

  20. Environmental Management Systems (EMS ISO 14001 Implementation in Construction Industry: A Malaysian Case Study

    Directory of Open Access Journals (Sweden)

    Sumiani Yusoff

    2015-03-01

    Full Text Available This study seeks to explore the crucial part in EMS implementation; i.e. environmental aspects and impacts, Good Environmental Practice to be developed in construction site, as well as the level of awareness or understanding amongst site staffs on ISO 14001 EMS implementation in their organizations. Data were collected via interviews, surveys and site visits. A number of environmental aspects and impacts, and Good Environmental Practices based on ISO 14001:2004 have been identified. The level of understanding of the site staffs on ISO 14001 EMS requirements has been found to be good except for matters concerning Schedule Waste Management. In conclusion, the successful implementation of ISO 14001 EMS mainly depends on staffs‘ understanding.

  1. [Validation of an in-house method for the determination of zinc in serum: Meeting the requirements of ISO 17025].

    Science.gov (United States)

    Llorente Ballesteros, M T; Navarro Serrano, I; López Colón, J L

    2015-01-01

    The aim of this report is to propose a scheme for validation of an analytical technique according to ISO 17025. According to ISO 17025, the fundamental parameters tested were: selectivity, calibration model, precision, accuracy, uncertainty of measurement, and analytical interference. A protocol has been developed that has been applied successfully to quantify zinc in serum by atomic absorption spectrometry. It is demonstrated that our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  2. ISO 14001 ENVIRONMENTAL MANAGEMENT SYSTEMS FOR GOVERNMENT

    Science.gov (United States)

    This presentation provides an overview of the document, ISO 14001 - A Tool for Supporting Government Environmental Programs and Policies, recently published by USEPA/s Office of Research and Development. It is an informational document, explaining the backjground and development ...

  3. Towards dynamic reference information models: Readiness for ICT mass customisation

    NARCIS (Netherlands)

    Verdouw, C.N.; Beulens, A.J.M.; Trienekens, J.H.; Verwaart, D.

    2010-01-01

    Current dynamic demand-driven networks make great demands on, in particular, the interoperability and agility of information systems. This paper investigates how reference information models can be used to meet these demands by enhancing ICT mass customisation. It was found that reference models for

  4. Performance improvement with ISO 9001:2000: a case of PKOC-II project

    Energy Technology Data Exchange (ETDEWEB)

    Behera, U.K.; Prasad, K.S.N. [Singareni Collieries Co. Ltd. (India)

    2006-07-01

    The present study is limited to the study of main step towards ISO 9001:2000 (QMS) development, implementation and improvements of PKOC-II project and the same are discussed. In line with increasing global concern for quality, environmental protection and occupational health and safety, Singareni Collieries Co. Ltd (SCCL) has taken the strategic decision to implement ISO 9001:2000 (QMS), ISO 14001:2004 EMS (environmental management system) and occupational health and safety assessment series 18001:1999 (OHSAS) at the PK OC-II project. This is the first project to implement all three management systems QMS, OHSAS, and EMS, in the Indian coal industry. 25 refs., 12 figs., 2 tabs.

  5. Mejoramiento de la calidad docente, utilización de la norma (ISO-10015 en el CETIS 104 IMPROVEMENT OF TEACHING QUALITY, USE TO ISO 10015 NORM IN CETIS 104

    Directory of Open Access Journals (Sweden)

    Fernández Pérez Jorge Alejandro

    2009-04-01

    Full Text Available Resumen: Con la formación docente, se hace referencia a un proceso de desarrollo más que a un programa de estudios o de aprendizaje que se realiza de manera permanente, y que pasa a través de una serie de etapas para adquirir conocimientos y habilidades. Debido a lo anterior, la formación del docente se presenta como una necesidad para el funcionamiento y desarrollo de cualquier organización educativa.Para este estudio se tomaron en cuenta los principios de gestión de la calidad que respaldan la familia de normas ISO (Organización Internacional de Estándares, que por primera vez ha desarrollado una norma sobre la formación y actualización por competencia laboral en el marco de un sistema de calidad, de la cual forma parte la serie ISO/DIS 10015:1999 que enfatiza la importancia de la gestión del recurso humano y la necesidad de una formación adecuada.El enfoque de la presente investigación fue cuantitativo, con la intención de detectar necesidades específicas de formación y actualización del personal docente del Centro de Estudios Tecnológicos Industrial y de Servicios No. 104 (CETis 104, y a partir de ello establecer los métodos y formas de cómo deberá ser proporcionada la formación y actualización.Abstract: With the teaching training, it made a process reference of development more like a study program or learning that to reach of permanent ways, and what happen through of the stage series to obtain knowledge and abilities’. Because of this, the teaching training its show like a need, wherever other case for the function and develop of the any education organization.For this study it takes the quality management principles than support the family rules ISO (International Standard Organization, that for the beginning has a development one rule over the training and actualization for professional abilities in the quality system framework, to give a part of the series ISO/DIS 10015:1999 than a important emphasize of the

  6. Molecular mechanisms behind the antimicrobial activity of hop iso-α-acids in Lactobacillus brevis.

    Science.gov (United States)

    Schurr, Benjamin C; Hahne, Hannes; Kuster, Bernhard; Behr, Jürgen; Vogel, Rudi F

    2015-04-01

    The main bittering component in beer, hop iso-α-acids, have been characterised as weak acids, which act as ionophores impairing microbial cells' function under acidic conditions as present in beer. Besides medium pH, divalent cations play a central role regarding the efficacy of the antimicrobial effect. The iso-α-acids' non-bitter derivatives humulinic acids can be found in isomerised hop extracts and can be generated during hop storage. Therefore, they have been under investigation concerning their influence on beer sensory properties. This study sketches the molecular mechanism behind iso-α-acids' antimicrobial activity in Lactobacillus (L.) brevis regarding their ionophore activity versus the dependence of the inhibitory potential on manganese binding, and suggests humulinic acids as novel tasteless food preservatives. We designed and synthesised chemically modified iso-α-acids to enhance the basic understanding of the molecular mechanism of antimicrobial iso-α-acids. It could be observed that a manganese-binding dependent transmembrane redox reaction (oxidative stress) plays a crucial role in inhibition. Privation of an acidic hydroxyl group neither erased ionophore activity, nor did it entirely abolish antimicrobial activity. Humulinic acids proved to be highly inhibitory, even outperforming iso-α-acids. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. An ISO 9001 quality management system in a hospital: bureaucracy or just benefits?

    Science.gov (United States)

    van den Heuvel, Jaap; Koning, Lida; Bogers, Ad J J C; Berg, Marc; van Dijen, Monique E M

    2005-01-01

    To describe how The Red Cross Hospital in Beverwijk, The Netherlands implemented an ISO 9000 quality management system throughout the entire organisation, obtained an ISO 9002:1994 and subsequently an ISO 9001:2000 certificate. First, a global implementation plan was written concerning the process obtaining in each department. Once improved, each process was subjected to a procedure, and specific protocols effected. On completion the Quality Manual was put together. Quality management was completed by implementing an internal audit system involving 50 co-workers. A number of advantages are found from using ISO. The focus on patients has been re-established. All processes are identified and subject to continuous improvement. Performance measurements were introduced and give an integrated picture of results. Measurements subsequently lead to improvement of quality of care and to quality system improvements. The documentation system serves the organization's needs without leading to bureaucracy. Positive effects on patient safety could be demonstrated compared with ten other hospitals. Given the need for adequate quality management tools in health care and the need for demonstrating quality, the positive effects reported in this article show how ISO is expected to become more prevalent in health-care organisations.

  8. KSC Center Director Bridges addresses the audience at an ISO 9001 certification ceremony

    Science.gov (United States)

    1998-01-01

    Center Director Roy Bridges speaks to KSC employees at the ISO certification ceremony held at the Training Auditorium. Bridges was presented an ISO 9001 certificate and plaque awarded to KSC by Det Norske Veritas (DNV), Inc., an international ISO certification organization. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world- class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification. Next to Bridges is Heidi Hollingsworth, with the Center for Independent Living, who uses American Sign Language for any hearing-impaired employees in the audience.

  9. Complementing network security to the ISO/IEC 27000 standard

    OpenAIRE

    Alila, Patrick

    2007-01-01

    I syfte att öppna upp nya affärsmöjligheter för informationssäkerhetsföretaget Secure State AB, har detta arbete bedrivits för att komplettera företagets nuvarande standard för informationssäkerhetsarbete med ytterligare nätverkssäkerhet. Krav på slutresultatet var att dokumentet eller standarden skulle kunna komplettera ISO 27000, samt vara kostnadseffektivt. Efter en undersökning av den nämnda standarden konstaterades att enbart ISO 27000 i sig inte är ett fullgott verktyg för nätverkssäker...

  10. Implementation of ISO 22000 in Romanian Companies: Motivations, Difficulties and Key Benefits

    Directory of Open Access Journals (Sweden)

    Carmen Păunescu

    2018-02-01

    Full Text Available The development of well-designed food safety management systems that take into consideration the potential risks and threats to an organization and their associated impacts to business operations should be a key goal for each organization operating in the food supply chain. This study provides quantitative empirical evidence about the motivations for implementing a food safety management system based on ISO 22000. By employing factor analysis and multiple linear regression, it analyses the benefits that the ISO 22000 certified companies gained through certification, as well as the main constraints that may prevent the adoption of the standard in the food industry. The survey is based on a sample of Romanian companies distributed at all levels of the food chain, but mainly at the production level. While there exist external pressures that lead companies to adopt a food safety management system based on ISO 22000, the motivations that are most relevant in this decision are generally internal in nature. The results of our study identify three major benefits of ISO 22000 certification: food safety improvement and provision of safer products, reduction of illness and other risks arising from food and improvement of consumers’ confidence. Also, it points out three constraints limiting the dissemination and use of ISO 22000: employees’ qualification, costs associated with food safety management system implementation and legal requirements.

  11. Adsorption and separation of n/iso-pentane on zeolites: A GCMC study.

    Science.gov (United States)

    Fu, Hui; Qin, Hansong; Wang, Yajun; Liu, Yibin; Yang, Chaohe; Shan, Honghong

    2018-03-01

    Separation of branched chain hydrocarbons and straight chain hydrocarbons is very important in the isomerization process. Grand canonical ensemble Monte Carlo simulations were used to investigate the adsorption and separation of iso-pentane and n-pentane in four types of zeolites: MWW, BOG, MFI, and LTA. The computation of the pure components indicates that the adsorption capacity is affected by physical properties of zeolite, like pore size and structures, and isosteric heat. In BOG, MFI and LTA, the amount of adsorption of n-pentane is higher than iso-pentane, while the phenomenon is contrary in MWW. For a given zeolite, a stronger adsorption heat corresponds to a higher loading. In the binary mixture simulations, the separation capacity of n-and iso-pentane increases with the elevated pressure and the increasing iso-pentane composition. The adsorption mechanism and competition process have been examined. Preferential adsorption contributions prevail at low pressure, however, the size effect becomes important with the increasing pressure, and the relatively smaller n-pentane gradually competes successfully in binary adsorption. Among these zeolites, MFI has the best separation performance due to its high shape selectivity. This work helps to better understand the adsorption and separation performance of n- and iso-pentane in different zeolites and explain the relationship between zeolite structures and adsorption performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Comparison of the Time Domain Windows Specified in the ISO 18431 Standards Used to Estimate Modal Parameters in Steel Plates

    Directory of Open Access Journals (Sweden)

    Jhonatan Camacho-Navarro

    2016-01-01

    Full Text Available The procedures used to estimate structural modal parameters as natural frequency, damping ratios, and mode shapes are generally based on frequency methods. However, methods of time-frequency analysis are highly sensible to the parameters used to calculate the discrete Fourier transform: windowing, resolution, and preprocessing. Thus, the uncertainty of the modal parameters is increased if a proper parameter selection is not considered. In this work, the influence of three different time domain windows functions (Hanning, flat-top, and rectangular used to estimate modal parameters are discussed in the framework of ISO 18431 standard. Experimental results are conducted over an AISI 1020 steel plate, which is excited by means of a hammer element. Vibration response is acquired by using acceleration records according to the ISO 7626-5 reference guides. The results are compared with a theoretical method and it is obtained that the flat-top window is the best function for experimental modal analysis.

  13. ISO 13485 a complete guide to quality management in the medical device industry

    CERN Document Server

    Abuhav, Itay

    2011-01-01

    Although complex and lengthy, the process of certification for the ISO 13485 can be easily mastered using the simple method outlined in ISO 13485: A Complete Guide to Quality Management in the Medical Device Industry. Written by an experienced industry professional, this practical book provides a complete guide to the ISO 13485 Standard certification for medical device manufacturing. Filled with examples drawn from the author's experience and spanning different sectors and fields of the medical device industry, the book translates the extra ordinary requirements and objectives of the standard

  14. Certification of CCHEN's products and services under ISO 9001/2000. A major and opportune challenge

    International Nuclear Information System (INIS)

    Silva Gundelach, Carmen

    2003-01-01

    The quality revolution and the ISO 9000 standards were among the most important management tools created during the second half of the 20th century. ISO 9000 is a management standard that allows an organization to demonstrate its quality level. It is a marketing instrument used for the difficult task of maintaining and winning new markets. More importantly, it is a proven and accepted worldwide model for an organizational system to attain a world quality level and to focus on 'continuous improvement'. For this reason, CCHEN cannot remain out of this new way of working. CCHEN must generate a record of its processes within the concept of Continuous Improvement, in order to be present and considered in today's marketplace. 'Continuous improving' is defined as a permanent activity and attitude aimed at increasing the ability to respond to a client's requirements. Taking into account the impact and importance of its products and services, CCHEN decided to request certification under ISO 9001/2000 of: Personal Dosimetry Service, Irradiation in the Multipurpose Sterilization Plant for the Pharmaceutical and Cosmetics Industry, Technetium-99m and MDP Production,and Production of MTR type Fuel Elements. This certification will demonstrate the quality level and the efficacy of each one of CCHEN's processes. Working under ISO 9001/2000 will allow CCHEN to organize and systematize information related to continuous improvement and focusing on client satisfaction clients, by defining their needs and expectations with the use of a management tool and most importantly by using information, facts and optimizing resources (Au)

  15. WHAT IS THE PURPOSE OF ISO 9000 CERTIFICATION? EMPIRICAL EVIDENCE FROM FRENCH MICRO-DATA

    Directory of Open Access Journals (Sweden)

    Sanja Pekovic

    2008-03-01

    Full Text Available The ISO 9000 certification is often associated with quality approach, and activities that are by now widely diffused throughout business. The statistical research shows that quality management practice is one of the most utilized tools because in 1997, more than a third of industrial firms have received the quality certification. Regarded like an investment in a diploma, investment in quality norms can at the same time be a function of improvement of the company's competence and can also make a signal on the market. In our research, we want to understand those two functions of the ISO 9000 certification and to see how they act in the company and on the market. The paper will explore two possible functions of the certification and will analysis the consequences for the firms. The research will use national statistics sources and case research for the empirical investigation to identify the internal characteristics of ISO 9000 adoption. Also, it will use C.O.I database (Organizational Changes and Computerization of 1997 and E.A.E. database (Annual Survey of Industry. In this research, the empirical results show that ISO certification has a part of increase the level of firm's export. Moreover, the firms that have recently adopted the ISO certification invest more in quality than those that have adopted ISO certification more ago. The results show that the firms from same sector of activity "are pushed" to adopt certification. At the end, the results show that, the probability that the firm adopt ISO certification increase with firm's size.

  16. Diseño e implantación de un sistema integrado de calidad y medio ambiente (ISO 9001: 2008 e ISO14001:2004) en una empresa de obra civil

    OpenAIRE

    Campano Calleja, Juan Manuel

    2012-01-01

    El Proyecto Fin de Carrera tiene como objetivos el diseño, desarrollo e implantación de un Sistema de Gestión Integrado de Calidad y de Medio Ambiente según las normas ISO 9001:2008 e ISO 14001:2004 para una empresa ficticia llamada MID EXCAVACIONES S.L.

  17. Study on the Evolution of the Current ISO Certifications in Romania

    Directory of Open Access Journals (Sweden)

    Teodor Socaciu

    2013-06-01

    Full Text Available To increase the efficiency and effectiveness of processes within an organization, ISO standards can help both large enterprises and small companies (SMEs, both in industrialized and in developing countries offering solutions and bringing considerable advantages in almost all existing fields. ISO certification brings a set of measures in the areas of an organization, be it about quality, environmental safety, food or protection and safety of personnel, this certification brings benefits both in the current processes and more importantly, the future development plans. In this paper, graphs showing the distributions of increasing certification, demonstrate that more and more companies in Romania have realized that, only implementing and certifying ISO standards, they will be successful in domestic and international market in terms of competition, in particular against European companies.

  18. 75 FR 16096 - New England Power Generators Association Inc., Complainant v. ISO New England Inc., Respondent...

    Science.gov (United States)

    2010-03-31

    ...-787-000] New England Power Generators Association Inc., Complainant v. ISO New England Inc., Respondent; ISO New England Inc. and New England Power Pool; Notice of Complaint March 24, 2010. Take notice... Inc. (Complainant) filed a formal complaint against ISO New England Inc. (Respondent) alleging that...

  19. Reference Model 6 (RM6): Oscillating Wave Energy Converter.

    Energy Technology Data Exchange (ETDEWEB)

    Bull, Diana L; Smith, Chris; Jenne, Dale Scott; Jacob, Paul; Copping, Andrea; Willits, Steve; Fontaine, Arnold; Brefort, Dorian; Gordon, Margaret Ellen; Copeland, Robert; Jepsen, Richard Alan

    2014-10-01

    This report is an addendum to SAND2013-9040: Methodology for Design and Economic Analysis of Marine Energy Conversion (MEC) Technologies. This report describes an Oscillating Water Column Wave Energy Converter reference model design in a complementary manner to Reference Models 1-4 contained in the above report. In this report, a conceptual design for an Oscillating Water Column Wave Energy Converter (WEC) device appropriate for the modeled reference resource site was identified, and a detailed backward bent duct buoy (BBDB) device design was developed using a combination of numerical modeling tools and scaled physical models. Our team used the methodology in SAND2013-9040 for the economic analysis that included costs for designing, manufacturing, deploying, and operating commercial-scale MEC arrays, up to 100 devices. The methodology was applied to identify key cost drivers and to estimate levelized cost of energy (LCOE) for this RM6 Oscillating Water Column device in dollars per kilowatt-hour ($/kWh). Although many costs were difficult to estimate at this time due to the lack of operational experience, the main contribution of this work was to disseminate a detailed set of methodologies and models that allow for an initial cost analysis of this emerging technology. This project is sponsored by the U.S. Department of Energy's (DOE) Wind and Water Power Technologies Program Office (WWPTO), within the Office of Energy Efficiency & Renewable Energy (EERE). Sandia National Laboratories, the lead in this effort, collaborated with partners from National Laboratories, industry, and universities to design and test this reference model.

  20. ISO19770-1:2012 SAM process guidance

    CERN Document Server

    Canavan, Rory

    2012-01-01

    The pocket guide offers a concise summary of the principles of software asset management as conveyed by ISO 19770-1: 2012, and provides advice and guidance on how to kick-start your own SAM programme - something the Standard alone doesn't offer.

  1. ITIL and ISO/IEC 20000 a practical handbook

    CERN Document Server

    Hernandez, Alex

    2012-01-01

    The purpose of this publication is to provide your organization with a pragmatic approach to effectively implementing service management, incorporating practices from the ITIL framework and the ISO/IEC 20000 standard.

  2. Upgrading the Medical Physics Calibration Laboratory Towards ISO/IEC 17025: Radiation Standards and Calibration in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Muhammad Jamal Md Isa; Abd Aziz Mhd Ramli; Wan Hazlinda Ismail; Norhayati Abdullah; Shahrul Azlan Azizan; Siti Sara Deraman; Nor Azlin Azraai; Md Khairusalih Md Zin

    2010-01-01

    Calibration of quality control (QC) test tools used in diagnostic radiology is legally required under the Ministry of Health (MOH) requirement. The Medical Physics Calibration Laboratory of the Malaysian Nuclear Agency is the national focal point for the calibration of quality control test tools used in diagnostic radiology. The Medical Physics Calibration Laboratory has measurement traceability to primary standard dosimetry laboratory (Physikalisch-Technische Bundesanstalt (PTB)), thus providing an interface between the primary standard dosimetry laboratory and Malaysian hospitals, clinics and license class H holder. The Medical Physics Calibration Laboratory facility is comprised of a constant potential x-ray system with a capability of 160 kV tube and a series of reference and working standard ion chambers. The stability of reference and working standard ion chambers was measured using strontium-90. Dosimetric instruments used in diagnostic radiology is calibrated in terms of air kerma to comply with an International Code of Practices of dosimetry for example IAEA's Technical Report Series number 457. The new series of standard radiation qualities was established based on ISO/IEC 61267. The measurement of beam homogeneity was measured using film and ion chamber to define the field size at certain distance and kV output was measured using the spectrometer and non-invasive kVp meter. The uncertainties measurement was determined with expended uncertainties to a level of confidence of approximately 95% (coverage factor k=2). This paper describes the available facility and the effort of the Medical Physics Calibration Laboratory to upgrade the laboratory towards ISO/IEC 17025. (author)

  3. Perceptual quality estimation of H.264/AVC videos using reduced-reference and no-reference models

    Science.gov (United States)

    Shahid, Muhammad; Pandremmenou, Katerina; Kondi, Lisimachos P.; Rossholm, Andreas; Lövström, Benny

    2016-09-01

    Reduced-reference (RR) and no-reference (NR) models for video quality estimation, using features that account for the impact of coding artifacts, spatio-temporal complexity, and packet losses, are proposed. The purpose of this study is to analyze a number of potentially quality-relevant features in order to select the most suitable set of features for building the desired models. The proposed sets of features have not been used in the literature and some of the features are used for the first time in this study. The features are employed by the least absolute shrinkage and selection operator (LASSO), which selects only the most influential of them toward perceptual quality. For comparison, we apply feature selection in the complete feature sets and ridge regression on the reduced sets. The models are validated using a database of H.264/AVC encoded videos that were subjectively assessed for quality in an ITU-T compliant laboratory. We infer that just two features selected by RR LASSO and two bitstream-based features selected by NR LASSO are able to estimate perceptual quality with high accuracy, higher than that of ridge, which uses more features. The comparisons with competing works and two full-reference metrics also verify the superiority of our models.

  4. [Quality management according to DIN EN ISO 9001 at a university eye hospital].

    Science.gov (United States)

    Schönherr, U; Händel, A; Naumann, G O

    2001-02-01

    Quality assurance is an integral part of modern microsurgical ophthalmology. Health care laws also mandate overall quality management. In recent years we have standardized the preexisting features of quality management according DIN EN ISO 9001 and have integrated previously missing features. Establishing quality management according to ISO 9001 is possible even at a university eye hospital and department of ophthalmology. Certification according to ISO 9001 specifications was granted in April 1999. The major difficulty was in translating industrial norms to the context of an eye hospital. It was also difficult to overcome skepticism towards quality-assurance measures that lie beyond ophthalmological quality control. It is useful and feasible to establish a quality management system at German university eye hospitals and departments of ophthalmology. Certification according to ISO 9001 is one possibility to make a quality management system transparent and evaluable both inside and outside the hospital.

  5. Aspirin provocation increases 8-iso-PGE2 in exhaled breath condensate of aspirin-hypersensitive asthmatics.

    Science.gov (United States)

    Mastalerz, Lucyna; Januszek, Rafał; Kaszuba, Marek; Wójcik, Krzysztof; Celejewska-Wójcik, Natalia; Gielicz, Anna; Plutecka, Hanna; Oleś, Krzysztof; Stręk, Paweł; Sanak, Marek

    2015-09-01

    Isoprostanes are bioactive compounds formed by non-enzymatic oxidation of polyunsaturated fatty acids, mostly arachidonic, and markers of free radical generation during inflammation. In aspirin exacerbated respiratory disease (AERD), asthmatic symptoms are precipitated by ingestion of non-steroid anti-inflammatory drugs capable for pharmacologic inhibition of cyclooxygenase-1 isoenzyme. We investigated whether aspirin-provoked bronchoconstriction is accompanied by changes of isoprostanes in exhaled breath condensate (EBC). EBC was collected from 28 AERD subjects and 25 aspirin-tolerant asthmatics before and after inhalatory aspirin challenge. Concentrations of 8-iso-PGF2α, 8-iso-PGE2, and prostaglandin E2 were measured using gas chromatography/mass spectrometry. Leukotriene E4 was measured by immunoassay in urine samples collected before and after the challenge. Before the challenge, exhaled 8-iso-PGF2α, 8-iso-PGE2, and PGE2 levels did not differ between the study groups. 8-iso-PGE2 level increased in AERD group only (p=0.014) as a result of the aspirin challenge. Urinary LTE4 was elevated in AERD, both in baseline and post-challenge samples. Post-challenge airways 8-iso-PGE2 correlated positively with urinary LTE4 level (p=0.046), whereas it correlated negatively with the provocative dose of aspirin (p=0.027). A significant increase of exhaled 8-iso-PGE2 after inhalatory challenge with aspirin was selective and not present for the other isoprostane measured. This is a novel finding in AERD, suggesting that inhibition of cyclooxygenase may elicit 8-iso-PGE2 production in a specific mechanism, contributing to bronchoconstriction and systemic overproduction of cysteinyl leukotrienes. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Value of flexible resources, virtual bidding, and self-scheduling in two-settlement electricity markets with wind generation - Part II: ISO Models and Application

    DEFF Research Database (Denmark)

    Kazempour, Jalal; Hobbs, Benjamin F.

    2017-01-01

    In Part II of this paper, we present formulations for three two-settlement market models: baseline cost-minimization (Stoch-Opt); and two sequential market models in which an independent system operator (ISO) runs real-time (RT) balancing markets after making day-ahead (DA) generating unit...... commitment decisions based upon deterministic wind forecasts, while virtual bidders arbitrage the two markets (Seq and SeqSS). The latter two models differ in terms of whether some slow-start generators can self-schedule in the DA market while anticipating probabilities of RT prices. Models in Seq and Seq......-SS build on components of the two-settlement equilibrium model (Stoch-MP) defined in Part I of this paper [1]. We then provide numerical results for all four models. A simple single-node case illustrates the economic impacts of flexibility, virtual bidding, and self-schedules, and is followed by a larger...

  7. Diseño e implantación de una oficina técnica según normativa ISO 9001:2000 e ISO 14001:2004, en una empresa del sector aeronautico

    OpenAIRE

    Hucha Sierra, Antonio

    2006-01-01

    El proyecto describirá dos procesos fundamentalmente, el diseño de la empresa de SITA enfocada hacia los Estudios de Ingeniería, y la implantación y certificación de un Sistema de Gestión de Calidad y Medioambiente, según las normativas ISO 9001:2000 e ISO 14001:2004.

  8. Implementation Of ISO 9000 Quality Management System Within The Manufacturing And Service Industry Of Ivory Coast

    Directory of Open Access Journals (Sweden)

    Borget Alfred Anoye

    2015-08-01

    Full Text Available Abstract The objective of this paper was to present the factors that impede the implementation of ISO 9000 QMS within the manufacturing and service Industry of Ivory Coast. It wasnt the intention of the author to provide detailed strategies for the readers to implement ISO 9000. It was an effort to present the relationship if any between the lack of ISO 9000 adoption and the perception of Ivoirians business organization leaders. For that purpose five research questions were associated with this study. The population for this study was all non-ISO certified business organizations in both public and private sector and was physically located in Ivory Coast. The population sample for this study was the 5044 members of the Chambre de Commerce et dIndustrie de Cote dIvoire CCI from which the author utilized the sample size of 60 business organizations randomly selected. This study utilized a survey questionnaire of face to face interview as data collection method. The survey questionnaire contained thirty three 33 questions organized in six parts and was proposed to 60 business organizations leaders. The result showed that business organization leaders in Ivory Coast were aware of the ISO 900 QMS but do not have enough knowledge on the ISO 9000 QMS implementation and certification. This could be due to the poor job done by CODIMORM the local national bureau of standards as a source of information. However it was found that business organization leaders in Ivory Coast intended to pursue and obtain ISO 9000 QMS certification. With respect to perceived benefits they indicated customer satisfaction improvement as the most important benefit that ISO 9000 QMS certification could bring to their general management activities. With respect to perceived improvements they selected quality of productsservices as the most important improvement that ISO 9000 QMS implementation and certification could help to achieve. Overall business organization leaders in Ivory

  9. On the new ISO guide on risk management terminology

    International Nuclear Information System (INIS)

    Aven, Terje

    2011-01-01

    A new ISO guide on risk management terminology has recently been issued. The guide provides basic vocabulary for developing a common understanding of risk assessment and risk management concepts and terms among organisations and functions, and across different application areas. It provides the foundation of, for example, the ISO 31000 standard on risk management. The guide strongly influences the risk assessment and risk management field, and its quality is thus of utmost importance. In this paper a critical review of the guide is conducted. We argue that the guide fails in several ways in producing consistent and meaningful definitions of many of the key concepts covered. A main focus is placed on the risk concept, which is defined as the effect of uncertainty on objectives, but also many other definitions are looked into, including probability, vulnerability, hazard, risk identification and risk description. Examples are used to illustrate the problems and show how they can be rectified. Although the focus is on the ISO guide, the discussion is to a large extent general. The overall aim of the paper is to contribute to the further development of the area of risk assessment and risk management by strengthening its conceptual basis.

  10. Relationship between platelet and urinary 8-Iso-PGF2α levels in subjects with different degrees of NOX2 regulation.

    Science.gov (United States)

    Carnevale, Roberto; Iuliano, Luigi; Nocella, Cristina; Bartimoccia, Simona; Trapè, Stefano; Russo, Roberta; Gentile, Maria Cristina; Cangemi, Roberto; Loffredo, Lorenzo; Pignatelli, Pasquale; Violi, Francesco

    2013-06-14

    Urinary 8-iso-PGF2α, a marker of oxidative stress, is influenced by the activation of NOX2. It is unclear if platelets 8-iso-PGF2α contribute to urinary 8-iso-PGF2α. In a cross-sectional study, platelet, urinary, and serum 8-iso-PGF2α were determined in subjects with downregulation (X-linked chronic granulomatous disease [X-CGD], n=25) and upregulation (type II diabetic patients [T2D], n=121) of NOX2 and 153 controls matched for sex and age. In diabetic patients (n=18), the above variables were repeated before and after 7 days treatment with 100 mg/day aspirin or 100 mg/day aspirin plus 40 mg/day atorvastatin. In vitro study was performed to see the contribution of blood cells to serum 8-iso-PGF2α. Compared with controls, X-CGD patients had lower platelet, serum, and urinary 8-iso-PGF2α values; conversely, diabetic patients had higher values of 8-iso-PGF2α compared with controls. Urinary 8-iso-PGF2α significantly correlated with both platelet and serum 8-iso-PGF2α in the 2 cohorts. A parallel increase of platelet, serum, and urinary 8-iso-PGF2α by aspirin and a parallel decrease by aspirin plus atorvastatin were detected in the interventional study. In vitro study demonstrated that platelets contribute to 37% of serum 8-iso-PGF2α and that only 13% of it is of extravascular origin. The study suggests that NOX2 contributes to the formation of 8-iso-PGF2α in both platelets and urine. The direct correlation between platelet and urinary 8-iso-PGF2α suggests that, at least partly, urinary 8-iso-PGF2α reflects platelet 8-iso-PGF2α production. Analysis of serum 8-iso-PGF2α may represent a novel tool to investigate the production of 8-iso-PGF2α by blood cells including platelets. URL: ClinicalTrials.gov. Unique Identifier: NCT01250340.

  11. ISO/IEC 38500 the IT governance standard

    CERN Document Server

    Calder, Alan

    2008-01-01

    The emergence of ISO/IEC 38500 - the international standard for the corporate governance of information and communication technology - puts boards around the world in a position from which they can take effective action to apply core governance principles to their information and communication technology.

  12. X(3872) and Its Iso-Triplet Partners

    OpenAIRE

    Kunihiko, TERASAKI; Yukawa Institute for Theoretical Physics, Kyoto University:Institute for Theoretical Physics, Kanazawa University

    2012-01-01

    Decays of X(3872) and its partners as hidden-charm axial-vector tetra-quark mesons are studied. As the result, it is seen that the iso-triplet partners of X(3872) can be broad, and therefore, higher statistics will be needed to find them.

  13. New ISO standards for hearing protectors (A)

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2000-01-01

    Working Group 17 under ISO/TC43/SC1 deals with measurement of hearing protector attenuation. WG17 is presently involved in revision of the present 4869-1 standard (especially sound field requirements and reproducibility estimations) and formulation of a new standard where inexperienced hearing...

  14. Conformance on Quality Management System of One State College in the Philippines as Basis for ISO Certification

    Directory of Open Access Journals (Sweden)

    Romulo T. Sisno

    2017-11-01

    Full Text Available This study sought to determine the quality management system of the Northern Negros State College of Science and Technology (NONESCOST as basis for International Organization for Standardization (ISO Certification. The descriptive method of research was used in this study. It utilized the ISO 9001:2008 Quality Management System Requirements Checklist and the Questionnaires on the Attitudes towards ISO 9001. The study utilized a descriptive research design.. Findings revealed that the attitude of administrators, teaching personnel and administrative staff’ towards ISO 9001 in terms of benefits, challenges, recommendations and standards did not differ significantly. Findings further revealed that the employees have mostly positive perceptions of ISO 9001, resulting in positive attitudes in the workplace. Findings also revealed that the extent of conformance to the ISO 9001:2008 (QMS Requirements in the areas of Quality Management System, Management Responsibility, Resource Management, Product Realization and Measurement, Analysis and Improvement was perceived by the respondents to be minor non-conformance. It implies that fulfillment to the ISO 9001:2008 Requirements was only satisfactory

  15. Why did ISO 9001:2008 system fail to deliver?

    Science.gov (United States)

    Langford, Melvyn

    2014-02-01

    This article is based on an actual investigation undertaken, and summarises the subsequent report's findings and observations. It has been anonymised for obvious reasons. In May 2013 an analysis was undertaken by a multidisciplinary team that compared an NHS Trust estates department's managerial systems against the NHS national recommendations. The conclusions stated that: 'There was a systemic failure across a large number of topics generating intolerable/substantial risks to the organisation, its staff, and patients; this despite the department's managerial systems being accredited to the International Standard ISO 9001:2008'. The natural question raised when presented with this demonstrable and auditable evidence was: 'Why did the ISO 9001:2008 system fail?'

  16. Reference Management Methodologies for Large Structural Models at Kennedy Space Center

    Science.gov (United States)

    Jones, Corey; Bingham, Ryan; Schmidt, Rick

    2011-01-01

    There have been many challenges associated with modeling some of NASA KSC's largest structures. Given the size of the welded structures here at KSC, it was critically important to properly organize model struc.ture and carefully manage references. Additionally, because of the amount of hardware to be installed on these structures, it was very important to have a means to coordinate between different design teams and organizations, check for interferences, produce consistent drawings, and allow for simple release processes. Facing these challenges, the modeling team developed a unique reference management methodology and model fidelity methodology. This presentation will describe the techniques and methodologies that were developed for these projects. The attendees will learn about KSC's reference management and model fidelity methodologies for large structures. The attendees will understand the goals of these methodologies. The attendees will appreciate the advantages of developing a reference management methodology.

  17. Shikonin ameliorates isoproterenol (ISO)-induced myocardial damage through suppressing fibrosis, inflammation, apoptosis and ER stress.

    Science.gov (United States)

    Yang, Jun; Wang, Zhao; Chen, Dong-Lin

    2017-09-01

    Shikonin, isolated from the roots of herbal plant Lithospermum erythrorhizon, is a naphthoquinone. It has been reported to exert beneficial anti-inflammatory effects and anti-oxidant properties in various diseases. Isoproterenol (ISO) has been widely used to establish cardiac injury in vivo and in vitro. However, shikonin function in ISO-induced cardiac injury remains uncertain. In our study, we attempted to investigate the efficiency and possible molecular mechanism of shikonin in cardiac injury treatment induced by ISO. In vivo, C57BL6 mice were subcutaneously injected with 5mg/kg ISO to induce heart failure. And mice were given a gavage of shikonin (2 or 4mg/kg/d, for four weeks). Cardiac function, fibrosis indices, inflammation response, apoptosis and endoplasmic reticulum (ER) stress were calculated. Pathological alterations, fibrosis-, inflammation-, apoptosis- and ER stress-related molecules were examined. In ISO-induced cardiac injury, shikonin significantly ameliorated heart function, decreased myocardial fibrosis, suppressed inflammation, attenuated apoptosis and ER stress through impeding collagen accumulation, Toll like receptor 4/nuclear transcription factor κB (TLR4/NF-κB), Caspase-3 and glucose-regulated protein 78 (GRP78) signaling pathways activity, relieving heart failure in vivo. Also, in vitro, shikonin attenuated ISO-induced cardiac muscle cells by reducing fibrosis, inflammation, apoptosis and ER stress. Our findings indicated that shikonin treatment attenuated ISO-induced heart injury, providing an effective therapeutic strategy for heart failure treatment for future. Copyright © 2017. Published by Elsevier Masson SAS.

  18. [Nine-Year Experience after ISO 15189 Acquisition, How Successful was It? Focusing on the Results of Interviews and Questionnaires].

    Science.gov (United States)

    Fujimoto, Kazumitsu; Asai, Noriaki; Nakajima, Yoshinaga; Inoue, Kaoru

    2015-11-01

    Our laboratory, for the purpose of Quality Management System (QMS) improvement, acquired ISO 15189:2003 accreditation 9 years ago and completed the renewal to ISO 15189:2012 last year. In this study, we reviewed the efficacy of ISO 15189 based on an analysis of laboratory director's and managers' opinions. We could realize QMS improvement through the proactive implementation of preventive and corrective actions, and also the continuous implementation of education and delivery by means of reviewing the interview records of ISO 15189:2012 renewal with the laboratory director. All answers to the questionnaire obtained from managers with regard to the advantages of ISO 15189 acquisition agreed with the purpose of ISO 15189. From these results, we concluded that ISO 15189 acquisition was successful for QMS improvement. [Review].

  19. So You Want to Be Trustworthy: A Repository's Guide to Taking Reasonable Steps Towards Achieving ISO 16363

    Science.gov (United States)

    Stall, S.

    2016-12-01

    To be trustworthy is to be reliable, dependable, honest, principled, ethical, incorruptible, and more. A trustworthy person demonstrates these qualities over time and under all circumstances. A trustworthy repository demonstrates these qualities through the team that manages the repository and its responsible organization. The requirements of a Trusted Digital Repository (TDR) in ISO 16363 can be tough to reach and tough to maintain. Challenges include: limited funds, limited resources and/or skills, and an unclear path to successfully achieve the requirements. The ISO standard defines each requirement separately, but a successful certification recognizes that there are many cross-dependencies among the requirements. Understanding these dependencies leads to a more efficient path towards success. At AGU we recognize that reaching the goal of the TDR ISO standard, or any set of data management objectives defined by an organization, has a better chance at success if the organization clearly knows their current capability, the improvements that are needed, and the best way to make (and maintain) those changes. AGU has partnered with the CMMI® Institute to adapt their Data Management Maturity (DMM)SM model within the Earth and space sciences. Using the DMM, AGU developed a new Data Management Assessment Program aimed at helping data repositories, large and small, domain-specific to general, assess and improve data management practices to meet their goals - including becoming a Trustworthy Digital Repository. The requirements to achieve the TDR ISO standard are aligned to the data management best practices defined in the Data Management Maturity (DMM)SM model. Using the DMM as a process improvement tool in conjunction with the Data Management Assessment method, a team seeking the objective of the TDR ISO standard receives a clear road map to achieving their goal as an outcome of the assessment. Publishers and agencies are beginning to recommend or even require that

  20. Management system quality of service radio physics and RR. ISO 9001

    International Nuclear Information System (INIS)

    Gil Agudo, A.; Torres Donaire, J.; Jimenez, J. C.; Carrascosa Fernandez, C.; Arjona Gutierrez, J.

    2011-01-01

    One of the tool increasingly deployed for the optimization of the procedures is the process management system according to a Quality Management. Likewise, for specific areas, such as central services within large institutions such as the General Hospitals of the systems of quality management is the most widely used ISO 9001. We describe in this paper our experience in implementing the system ISO 9001 in our Department of Radio physics and Radiation Protection (SRFPR).

  1. Effect of Mailuoning injection on 8-iso-prostaglandin F2 alpha and superoxide dismutase in rabbits with extremity ischemia-reperfusion injury.

    Science.gov (United States)

    Wang, Dai-Jun; Tian, Hua

    2014-12-01

    To date, there are no effective treatments for extremity ischemia-reperfusion (IR) injury. The objective of the present study was to explore the protective effect of Mailuoning on IR injury by investigating the plasma levels of 8-iso-prostaglandin F2 alpha (8-iso-PGF2α) and the activity of superoxide dismutase (SOD) in rabbits. The experimental models of posterior limb IR injury were established in thirty rabbits that were divided into three groups: the sham, IR, and IR + Mailuoning groups. At the end of ischemia, Mailuoning was injected intravenously into the rabbits in the IR + Mailuoning group, and normal saline solution was administered to the rabbits in the sham and IR groups. Venous blood samples were collected to measure the levels of 8-iso-PGF2α and the activity of SOD in the plasma at the following time points: at the onset of ischemia, the end of ischemia, and 2, 4, 8, 12, and 24 h after reperfusion. The skeletal muscles were harvested to examine the ultrastructure. The levels of 8-iso-PGF2α increased significantly and SOD activity decreased in the IR group at every time point after reperfusion (P iso-PGF2α and SOD activity were not significantly different after reperfusion in the IR + Mailuoning group (P >0.05) but were significantly different compared with the IR group (P iso-PGF2α and protecting SOD activity, thereby exhibiting a protective effect on extremity IR injury. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. 45 CFR 170.499 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ..., Switzerland, telephone +41-22-749-01-11, http://www.iso.org. (1) ISO/IEC 17025 General Requirements for the... and § 170.423. (2) ISO/IEC GUIDE 65 General Requirements for Bodies Operating Product Certification...

  3. ncISO Facilitating Metadata and Scientific Data Discovery

    Science.gov (United States)

    Neufeld, D.; Habermann, T.

    2011-12-01

    Increasing the usability and availability climate and oceanographic datasets for environmental research requires improved metadata and tools to rapidly locate and access relevant information for an area of interest. Because of the distributed nature of most environmental geospatial data, a common approach is to use catalog services that support queries on metadata harvested from remote map and data services. A key component to effectively using these catalog services is the availability of high quality metadata associated with the underlying data sets. In this presentation, we examine the use of ncISO, and Geoportal as open source tools that can be used to document and facilitate access to ocean and climate data available from Thematic Realtime Environmental Distributed Data Services (THREDDS) data services. Many atmospheric and oceanographic spatial data sets are stored in the Network Common Data Format (netCDF) and served through the Unidata THREDDS Data Server (TDS). NetCDF and THREDDS are becoming increasingly accepted in both the scientific and geographic research communities as demonstrated by the recent adoption of netCDF as an Open Geospatial Consortium (OGC) standard. One important source for ocean and atmospheric based data sets is NOAA's Unified Access Framework (UAF) which serves over 3000 gridded data sets from across NOAA and NOAA-affiliated partners. Due to the large number of datasets, browsing the data holdings to locate data is impractical. Working with Unidata, we have created a new service for the TDS called "ncISO", which allows automatic generation of ISO 19115-2 metadata from attributes and variables in TDS datasets. The ncISO metadata records can be harvested by catalog services such as ESSI-labs GI-Cat catalog service, and ESRI's Geoportal which supports query through a number of services, including OpenSearch and Catalog Services for the Web (CSW). ESRI's Geoportal Server provides a number of user friendly search capabilities for end users

  4. Development of international standards for surface analysis by ISO technical committee 201 on surface chemical analysis

    International Nuclear Information System (INIS)

    Powell, C.J.

    1999-01-01

    Full text: The International Organization for Standardization (ISO) established Technical Committee 201 on Surface Chemical Analysis in 1991 to develop documentary standards for surface analysis. ISO/TC 201 met first in 1992 and has met annually since. This committee now has eight subcommittees (Terminology, General Procedures, Data Management and Treatment, Depth Profiling, AES, SIMS, XPS, and Glow Discharge Spectroscopy (GDS)) and one working group (Total X-Ray Fluorescence Spectroscopy). Each subcommittee has one or more working groups to develop standards on particular topics. Australia has observer-member status on ISO/TC 201 and on all ISO/TC 201 subcommittees except GDS where it has participator-member status. I will outline the organization of ISO/TC 201 and summarize the standards that have been or are being developed. Copyright (1999) Australian X-ray Analytical Association Inc

  5. Laboratory quality stepwise implementation tool: National reference TB laboratory of Iran

    OpenAIRE

    Ali Naghi Kebriaee; Donya Malekshahian; Mojtaba Ahmadi; Parissa Farnia

    2015-01-01

    Background and objective: During recent years, the World Health Organization (WHO) proposed new software for improving the tuberculosis (TB) laboratory services. The protocol is known as “quality stepwise implementation tool” and is based on enforcement of quality assurance services through accreditation by the International Organization for Standardization (ISO) 15189. As a national reference TB laboratory (NRL) of Iran, the benefit and challenges of implementing this standard were analyzed....

  6. Isorhapontigenin (ISO) Inhibits Invasive Bladder Cancer Formation In Vivo and Human Bladder Cancer Invasion In Vitro by Targeting STAT1/FOXO1 Axis.

    Science.gov (United States)

    Jiang, Guosong; Wu, Amy D; Huang, Chao; Gu, Jiayan; Zhang, Liping; Huang, Haishan; Liao, Xin; Li, Jingxia; Zhang, Dongyun; Zeng, Xingruo; Jin, Honglei; Huang, Haojie; Huang, Chuanshu

    2016-07-01

    Although our most recent studies have identified Isorhapontigenin (ISO), a novel derivative of stilbene that isolated from a Chinese herb Gnetum cleistostachyum, for its inhibition of human bladder cancer growth, nothing is known whether ISO possesses an inhibitory effect on bladder cancer invasion. Thus, we addressed this important question in current study and discovered that ISO treatment could inhibit mouse-invasive bladder cancer development following bladder carcinogen N-butyl-N-(4-hydroxybutyl) nitrosamine (BBN) exposure in vivo We also found that ISO suppressed human bladder cancer cell invasion accompanied by upregulation of the forkhead box class O 1 (FOXO1) mRNA transcription in vitro Accordingly, FOXO1 was profoundly downregulated in human bladder cancer tissues and was negatively correlated with bladder cancer invasion. Forced expression of FOXO1 specifically suppressed high-grade human bladder cancer cell invasion, whereas knockdown of FOXO1 promoted noninvasive bladder cancer cells becoming invasive bladder cancer cells. Moreover, knockout of FOXO1 significantly increased bladder cancer cell invasion and abolished the ISO inhibition of invasion in human bladder cancer cells. Further studies showed that the inhibition of Signal transducer and activator of transcription 1 (STAT1) phosphorylation at Tyr701 was crucial for ISO upregulation of FOXO1 transcription. Furthermore, this study revealed that metalloproteinase-2 (MMP-2) was a FOXO1 downstream effector, which was also supported by data obtained from mouse model of ISO inhibition BBN-induced mouse-invasive bladder cancer formation. These findings not only provide a novel insight into the understanding of mechanism of bladder cancer's propensity to invasion, but also identify a new role and mechanisms underlying the natural compound ISO that specifically suppresses such bladder cancer invasion through targeting the STAT1-FOXO1-MMP-2 axis. Cancer Prev Res; 9(7); 567-80. ©2016 AACR. ©2016 American

  7. 78 FR 38027 - ISO New England Inc.; Notice of Initiation of Proceeding and Refund Effective Date

    Science.gov (United States)

    2013-06-25

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-72-000] ISO New England... III.A.15 of Appendix A of ISO New England Inc.'s existing tariff. Dominion Energy Marketing, Inc. and ISO New England Inc., 143 FERC ] 61,233 (2013). The refund effective date in Docket No. EL13-72-000...

  8. Integración de las normas ISO 9001 e ISO INEN 22716 en la metodología apropiada con la industria de cosméticos de Quito

    OpenAIRE

    Mora Quishpe, Juan Carlos

    2015-01-01

    The following research the integration of ISO 9001: 2008 "Quality Management Systems" INEN and ISO 22716: 2013 "Cosmetics Good Manufacturing Practices" in an appropriate methodological guide to the cosmetics industry Quito, in order for organizations that manufacture cosmetics in the city, improve the quality of their products. Initially the diagnosis of the cosmetic was held in Quito, with regard to the number of manufacturers of these industries registered by the National Health Authorit...

  9. Influence of motivations for seeking ISO 14001 certification on perceptions of EMS effectiveness in China.

    Science.gov (United States)

    Fryxell, Gerald E; Lo, Carlos Wing-Hung; Chung, Shan Shan

    2004-02-01

    This study examines the motivations of mainland Chinese facilities in seeking ISO 14001 certification and examines the linkages between these motivations and self-reports of the effectiveness of major environmental management system (EMS) components. In a sample of 128 facilities in Beijing, Shanghai, and Guangzhou, the main drivers for certification were reported to be to ensure regulatory compliance, to enhance the firm's reputation, and to improve environmental performance, in that order. Although motivation to achieve cost reductions were least emphasized, a broad range of motivations appears to be considered in the decision to seek certification to ISO 14001. Regression models linking these motivations to the EMS components suggests that internal motivations have an influence on most EMS components. One interesting exception to this, however, is that no significant relationship was observed between internal motivations and the promulgation of environmental objectives and targets. The relationships associated with external motivations for certification (i.e., those in response to customer and other stakeholder pressures) and EMS components, on the other hand, are weaker and tend to occur earlier in the process cycle. No significant relationships were found between motivations to reduce costs and perceptions of the effectiveness of EMS components. Overall, these findings suggest that ISO 14001, as currently being implemented in mainland China, may have a modestly useful role when used in combination with other policy mechanisms to move the Chinese economy toward more sustainable practices. It is asserted that the ISO standard could provide even greater benefits if Chinese registrars were more proactive in developing EMS in conjunction with even more rigorous third-party audits.

  10. [Customer satisfaction with a quality management system according to DIN EN ISO 9001:2000: Increase in the satisfaction of cooperating clinics].

    Science.gov (United States)

    Beholz, Sven; Konertz, Wolfgang

    2006-01-01

    The evaluation of customers' satisfaction is elementary for any quality management system. In our university cardiac surgery unit that has been certified according to DIN EN ISO 9001:2000 the influence of repeated evaluation of the referring physicians' satisfaction conducted in the course of three consecutive years on structures and processes in the scope of the quality management system was examined. Customers' satisfaction with the possibility of access to the department could be increased by targeted interventions. Further interventions in the field of documentation led to a measurable increase in satisfaction with postoperative communication. Repeated annual evaluation of the satisfaction of referring physicians has proved to be a valuable tool in the process of continuous quality improvement.

  11. An implicit adaptation algorithm for a linear model reference control system

    Science.gov (United States)

    Mabius, L.; Kaufman, H.

    1975-01-01

    This paper presents a stable implicit adaptation algorithm for model reference control. The constraints for stability are found using Lyapunov's second method and do not depend on perfect model following between the system and the reference model. Methods are proposed for satisfying these constraints without estimating the parameters on which the constraints depend.

  12. Mapping ‘hydroscapes’ along the iso- to anisohydric continuum of stomatal regulation of plant water status

    Science.gov (United States)

    Frederick C. Meinzer; David R. Woodruff; Danielle E. Marias; Duncan D. Smith; Katherine A. McCulloh; Ava R. Howard; Alicia L. Magedman; Josep Penuelas

    2016-01-01

    The concept of iso- vs. anisohydry has been used to describe the stringency of stomatal regulation of plant water potential (ψ). However, metrics that accurately and consistently quantify species’ operating ranges along a continuum of iso- to anisohydry have been elusive. Additionally, most approaches to quantifying iso/anisohydry require labour-intensive measurements...

  13. [ISO 15189 accreditation in clinical microbiology laboratory: general concepts and the status in our laboratory].

    Science.gov (United States)

    Akyar, Işin

    2009-10-01

    One important trend in the laboratory profession and quality management is the global convergence of laboratory operations. The goal of an accredited medical laboratory is to continue "offering useful laboratory service for diagnosis and treatment of the patients and also aid to the health of the nation". An accredited clinical laboratory is managed by a quality control system, it is competent technically and the laboratory service meets the needs of all its patients and physicians by taking the responsibility of all the medical tests and therapies. For this purpose, ISO 15189 international standard has been prepared by 2003. ISO 15189 standard is originated from the arrangement of ISO 17025 and ISO 9001:2000 standards. Many countries such as England, Germany, France, Canada and Australia have preferred ISO 15189 as their own laboratory accreditation programme, meeting all the requirements of their medical laboratories. The accreditation performance of a clinical microbiology laboratory is mainly based on five essential points; preanalytical, analytical, postanalytical, quality control programmes (internal, external, interlaboratory) and audits (internal, external). In this review article, general concepts on ISO 15189 accreditation standards for the clinical microbiology laboratories have been summarized and the status of a private laboratory (Acibadem LabMed, Istanbul) in Turkey has been discussed.

  14. EFEKTIVITAS PENGOPERASIAN INSTALASI PENGOLAH AIR LIMBAH (IPAL PERUSAHAAN PERAIH SERTIFIKASI ISO 14001 DI KAWASAN SIMONGAN KOTA SEMARANG (The Effectivity of Waste Water Treatment Plan Operated by Industrial Companies Holding ISO 14001 Certificate

    Directory of Open Access Journals (Sweden)

    Zaenuri Zaenuri

    2012-07-01

    Full Text Available ABSTRAK Penelitian ini bertujuan untuk menganalisis efektivitas pengoperasian instalasi pengolah air limbah (IPAL perusahaan peraih sel1ifikasi ISO 14001 di Kawasan Simongan Kota Semarang. Data yang diperoleh dianalisis secara deskriptif-komparatif dan inferensial dengan menggunakan uji-t. Hasil penelitian menunjukkan, pada perusahaan farmasi, rata-rata konsentrasi TSS, BOD, dan COD periode 1989-1998 (sebelum memperoleh ISO 14001 masing-masing sebesar 92,3229 mg/I, 45,5022 mg/I, dan 87,3691 mg/I, sedangkan rata-rata pH sebesar 7,2388. Parameter BOD dan COD memenuhi baku mutu, pH dalam interval baku mutu yang ditetapkan, sedangkan TSS berada di atas baku mutu. ABSTRACT This research was intended to analyze the effectivity of  waste water treatment plan operated by industrial companies holding ISO 14001 certificates in Simongan Area of SemarangCity. The data were analyzed descriptively, comparatively and inferentially using t-tests. The analyses showed that prior to obtaining ISO 14001 certificate (1989-1998, the pharmaeutical company had its average concentrations of TSS, BOD, and COD of 92.3229, 45.5022 and 87.3691 mg/l respectively, with an average pH of 7.2388. These parameters of BOD and COD had already met the prevailing standard qualities, the TSS parameter was above the standard quality, and the pH was within the prevailing standard quality interval. After obtaining the ISO 14001 certificate (2005-2008, this pharmaeutical company was able to maintain all of the key parameters to meet the prevailing stadard qualities. In case of the galvanizing company prior to obtaining ISO 14001 certificate (1989-1998, its average concentrations of TSS and CN were 256.3469 and 0.25575 mg/l respectively (above the prevailing standard qualities, those for total Cr, C+6, Cu, Zn, Ni, and Pb were 0.0510, 0.0036, 0.236060, 0.7242, 0.01790 and 0.0286 mg/l respectively (still under the prevailing standard qualities, while the an average pH was within the

  15. Plan de implementación de la ISO/IEC 27001:2013

    OpenAIRE

    Gorriti Aranguren, Iñaki

    2015-01-01

    En el desarrollo del proyecto se analizaron las directrices establecidas en la norma ISO/IEC 27001:2013, que especifica los requisitos necesarios para establecer, implantar, mantener y mejorar un SGSI mediante un proceso de mejora continua. In the development there were analyzed the directives established in the norm ISO/IEC27001:2013, which specifies the necessary requirements to establish, to implement, to support and to improve a SGSI by means of a process of constant improvement. En...

  16. Effective energy management system using ISO 9000/14000 concept industries

    International Nuclear Information System (INIS)

    Asfaazam Kasbani; Kamaruzzaman Sopian

    2006-01-01

    Energy management is a system of managing energy utilization wisely and it includes issues such as energy efficiency (conservation), use of renewable energy, use of technology and development of energy policy. Its benefits has been well known for cost reduction and increase competitiveness and also other indirect impact such as preserving the natural resources and reduction of green-house gases. Although various strategies have been formulated by the government for the industries to adopt energy management, the result seems to be minimal and stagnant in some ways due to the various barriers which exists. Industries on the other hand, have successfully welcomed two famous management system namely the Environmental Management System ISO 14000 and the Quality Management System ISO 9000 to be implemented at their premises. This paper shows how energy management system can be effectively implemented by comparing similar generic management elements of energy management to ISO 9000/14000 standards. The seven (7) elements of energy management system discussed are top management commitment, policy establishment, energy management team, energy audit, energy efficiency projects, monitoring and training

  17. ISOS: A job evaluation system to implement comparable worth

    Directory of Open Access Journals (Sweden)

    Albert Corominas

    2008-01-01

    Full Text Available A fair pay structure is an essential element of the personnel policy of a firm. If the pay structure is perceived as arbitrary by the members of the staff, it becomes a cause of disturbance of the labor relations. Particularly, a pay structure is unfair if it discriminates against women. Job evaluation is a traditional tool used by companies to assist in the process of determining pay structures that can be also useful to detect and combat wage discrimination, since allow determining whether two jobs are of comparable worth or not. Although there are many kinds of systems, authors agree when defining point factor methods as the most appropriate and fair job evaluation systems. However, even being well defined from a technical point of view, most existing systems give discriminatory results regarding to gender. ISOS, a new job evaluation system which is described in this paper, has been designed, with the aim to define a neutral system with regard to gender, based on present jobs characteristics, existing job evaluation systems and job description questionnaires, international experts’ knowledge and a wide body of literature on gender discrimination and its relation with job evaluation. Using ISOS can contribute to detect, combat and eliminate part of the existing wage discrimination in general and, in particular, against women. ISOS includes all aspects of the work so no characteristics are omitted. The system can be applied in any company and to evaluate any job, and offers flexibility to be adapted to the specific characteristics of an organization. ISOS can also be used to detect and combat wage discrimination. Furthermore, characteristics of present jobs, such as cross-training or flexible working time, are also included so the system can be considered innovative in a very traditional field of industrial engineering.

  18. Correlating the content and context of PAS 55 with the ISO 55000 series

    Directory of Open Access Journals (Sweden)

    Van den Honert, A. F.

    2013-08-01

    Full Text Available The ISO 55000 series is soon to supersede PAS 55 as the most recognised international standard for asset management. A correlation of the content and context of PAS 55 with the ISO 55000 series is required to assist organisations with the transition. After analysis of the structures, similarities, differences, and omissions of the two standards, a map was created to correlate the summarised content and context. The map established that, although both sets of standards have a similar structural framework, the ISO 55000 series is a more comprehensive and detailed standard, creating a clearer way to implement an asset management system within an organisation.

  19. Towards a reference model for portfolio management for product development

    DEFF Research Database (Denmark)

    Larsson, Flemming

    2006-01-01

    The aim of this paper is to explore the concept of portfolio management for product development at company level. Departing from a combination of explorative interviews with industry professionals and a literature review a proposal for a reference model for portfolio management is developed....... The model consists of a set of defined and interrelated concepts which forms a coherent and consistent reference model that explicate the totality of the portfolio management concept at company level in terms of structure, processes and elements. The model simultaneously pinpoints, positions and integrates...... several central dimensions of portfolio management....

  20. EFFICIENCY OF ISO 9001 IN PORTUGAL: A QUALITATIVE STUDY FROM A HOLISTIC THEORETICAL PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    Alcina Dias

    2013-03-01

    Full Text Available The purpose of this paper is to analy se the efficiency of ISO 9001 from a holistic theoretical approach where the Contingency theory, the Institutional theory and the Resources-Based View are integrated. The study was carried out in companies of different sectors of activity in Portugal, based on a qualitative methodology (interviews. The fact of the interviews having been undertaken under an ISO 9001 structure made it easier for companies to grasp the issues under investigation. An ISO 9001 characterisation was carried out on a theoretical framework approach and findings point out efficiency gains and revealed that the absence of ISO 9001 would work as a competitive disadvantage. The contribution of this research aims to reinforce the state of art as concerns the theoretical scope of analysis of these issues enriched by the case study achievement.