WorldWideScience

Sample records for irritation test epiocular-eit

  1. The EpiOcular Eye Irritation Test (EIT) for hazard identification and labelling of eye irritating chemicals: protocol optimisation for solid materials and the results after extended shipment.

    Science.gov (United States)

    Kaluzhny, Yulia; Kandárová, Helena; Handa, Yuki; DeLuca, Jane; Truong, Thoa; Hunter, Amy; Kearney, Paul; d'Argembeau-Thornton, Laurence; Klausner, Mitchell

    2015-05-01

    The 7th Amendment to the EU Cosmetics Directive and the EU REACH Regulation have reinforced the need for in vitro ocular test methods. Validated in vitro ocular toxicity tests that can predict the human response to chemicals, cosmetics and other consumer products are required for the safety assessment of materials that intentionally, or inadvertently, come into contact with the eye. The EpiOcular Eye Irritation Test (EIT), which uses the normal human cell-based EpiOcular™ tissue model, was developed to address this need. The EpiOcular-EIT is able to discriminate, with high sensitivity and accuracy, between ocular irritant/corrosive materials and those that require no labelling. Although the original EpiOcular-EIT protocol was successfully pre-validated in an international, multicentre study sponsored by COLIPA (the predecessor to Cosmetics Europe), data from two larger studies (the EURL ECVAM-COLIPA validation study and an independent in-house validation at BASF SE) resulted in a sensitivity for the protocol for solids that was below the acceptance criteria set by the Validation Management Group (VMG) for eye irritation, and indicated the need for improvement of the assay's sensitivity for solids. By increasing the exposure time for solid materials from 90 minutes to 6 hours, the optimised EpiOcular-EIT protocol achieved 100% sensitivity, 68.4% specificity and 84.6% accuracy, thereby meeting all the acceptance criteria set by the VMG. In addition, to satisfy the needs of Japan and the Pacific region, the EpiOcular-EIT method was evaluated for its performance after extended shipment and storage of the tissues (4-5 days), and it was confirmed that the assay performs with similar levels of sensitivity, specificity and reproducibility in these circumstances. 2015 FRAME.

  2. Eye Irritation Test (EIT) for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial (RhCE) Tissue Model.

    Science.gov (United States)

    Kaluzhny, Yulia; Kandárová, Helena; d'Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell

    2015-08-23

    To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492.

  3. Development of the EpiOcular(TM) eye irritation test for hazard identification and labelling of eye irritating chemicals in response to the requirements of the EU cosmetics directive and REACH legislation.

    Science.gov (United States)

    Kaluzhny, Yulia; Kandárová, Helena; Hayden, Patrick; Kubilus, Joseph; d'Argembeau-Thornton, Laurence; Klausner, Mitchell

    2011-09-01

    The recently implemented 7th Amendment to the EU Cosmetics Directive and the EU REACH legislation have heightened the need for in vitro ocular test methods. To address this need, the EpiOcular(TM) eye irritation test (EpiOcular-EIT), which utilises the normal (non-transformed) human cell-based EpiOcular tissue model, has been developed. The EpiOcular-EIT prediction model is based on an initial training set of 39 liquid and 21 solid test substances and uses a single exposure period and a single cut-off in tissue viability, as determined by the MTT assay. A chemical is classified as an irritant (GHS Category 1 or 2), if the tissue viability is ≤ 60%, and as a non-irritant (GHS unclassified), if the viability is > 60%. EpiOcular-EIT results for the training set, along with results for an additional 52 substances, which included a range of alcohols, hydrocarbons, amines, esters, and ketones, discriminated between ocular irritants and non-irritants with 98.1% sensitivity, 72.9% specificity, and 84.8% accuracy. To ensure the long-term commercial viability of the assay, EpiOcular tissues produced by using three alternative cell culture inserts were evaluated in the EpiOcular-EIT with 94 chemicals. The assay results obtained with the initial insert and the three alternative inserts were very similar, as judged by correlation coefficients (r²) that ranged from 0.82 to 0.96. The EpiOcular-EIT was pre-validated in 2007/2008, and is currently involved in a formal, multi-laboratory validation study sponsored by the European Cosmetics Association (COLIPA) under the auspices of the European Centre for the Validation of Alternative Methods (ECVAM). The EpiOcular-EIT, together with EpiOcular's long history of reproducibility and proven utility for ultra-mildness testing, make EpiOcular a useful model for addressing current legislation related to animal use in the testing of potential ocular irritants. 2011 FRAME.

  4. CON4EI: SkinEthic™ Human Corneal Epithelium Eye Irritation Test (SkinEthic™ HCE EIT) for hazard identification and labelling of eye irritating chemicals.

    Science.gov (United States)

    Van Rompay, A R; Alépée, N; Nardelli, L; Hollanders, K; Leblanc, V; Drzewiecka, A; Gruszka, K; Guest, R; Kandarova, H; Willoughby, J A; Verstraelen, S; Adriaens, E

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies. Copyright © 2017. Published by Elsevier Ltd.

  5. CON4EI: EpiOcular™ Eye Irritation Test (EpiOcular™ EIT) for hazard identification and labelling of eye irritating chemicals.

    Science.gov (United States)

    Kandarova, H; Letasiova, S; Adriaens, E; Guest, R; Willoughby, J A; Drzewiecka, A; Gruszka, K; Alépée, Nathalie; Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI project was to develop tiered testing strategies for eye irritation assessment. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different methods. Here, the results obtained with the EpiOcular™ Eye Irritation Test (EIT), adopted as OECD TG 492, are shown. The primary aim of this study was to evaluate of the performance of the test method to discriminate between chemicals not requiring classification for serious eye damage/eye irritancy (No Category) and chemicals requiring classification and labelling. In addition, the predictive capacity in terms of in vivo drivers of classification (i.e. corneal opacity, conjunctival redness and persistence at day 21) was investigated. EpiOcular™ EIT achieved a sensitivity of 97%, a specificity of 87% and accuracy of 95% and also confirmed its excellent reproducibility (100%) from the original validation. The assay was applicable to all chemical categories tested in this project and its performance was not limited to the particular driver of the classification. In addition to the existing prediction model for dichotomous categorization, a new prediction model for Cat 1 is suggested. Copyright © 2017. Published by Elsevier Ltd.

  6. Vitrigel-eye irritancy test method using HCE-T cells.

    Science.gov (United States)

    Yamaguchi, Hiroyuki; Kojima, Hajime; Takezawa, Toshiaki

    2013-10-01

    We previously reported that the time-dependent relative changes of transepithelial electrical resistance (TEER) after exposing four different chemicals to a human corneal epithelium (HCE) model were well correlated to the potential of ocular irritancy. Meanwhile, we recently developed a collagen vitrigel membrane (CVM) chamber possessing a scaffold composed of high-density collagen fibrils equivalent to connective tissues in vivo as a three-dimensional culture tool. The CVM chamber is useful for biomedical assays and immunohistology using cryosections that are inappropriate to be performed using the conventional Millicell chamber with a polyethylene terephthalate membrane. In this study, we aimed to develop a new eye irritancy test (EIT) method called "Vitrigel-EIT method" that can facilitate to briefly and accurately estimate the widespread irritancy of test chemicals by applying the TEER assay system to a HCE model fabricated in the CVM chamber. HCE-T cells (a HCE-derived cell strain) were cultured in the CVM chamber for 6 days, and consequently, the Vitrigel-HCE model possessing the following characteristics of HCE in vivo was formed: six cell layers with specific protein expressions and their barrier function. Time-dependent profiles of TEER values after exposing 30 test chemicals to the HCE model were converted into the scores of three indexes (time lag, intensity, and plateau level), and each chemical was successfully classified into irritant or nonirritant category by utilizing the criteria for the indexes, resulting in the excellent correlation with Globally Harmonized System of Classification and Labelling of Chemicals (GHS) classification (sensitivity: 100%, specificity: 75%, accuracy: 90%). These data suggest that the widespread eye irritancy of chemicals can be predicted without false negatives by the Vitrigel-EIT method. Interestingly, the disruption of tight junctions was immunohistologically observed after exposing not only irritants but also three

  7. Prevalidation trial for a novel in vitro eye irritation test using the reconstructed human cornea-like epithelial model, MCTT HCE™.

    Science.gov (United States)

    Yang, Hyeri; Kim, Da-Eun; Jang, Won-Hee; An, Susun; Cho, Sun-A; Jung, Mi-Sook; Lee, Ji Eun; Yeo, Kyung-Wook; Koh, Sang Bum; Jeong, Tae-Cheon; Kang, Mi-Jeong; Chun, Young-Jin; Lee, Su-Hyon; Lim, Kyung-Min; Bae, SeungJin

    2017-03-01

    Here, we report the results of a prevalidation trial for an in vitro eye irritation test (EIT) using the reconstructed human cornea-like epithelium, MCTT HCE™. The optimal cutoff to determine irritation in the prediction model was established at 35% with the receiver operation characteristics(ROC) curve for 126 substances. Within-lab(WL) and between-lab(BL) reproducibility was tested for 20 reference substances by 3 participating laboratories. Viability data described by mean±SD or ±1/2 difference between duplicate wells, and scatter plots, demonstrated the WL/BL consistency. WL/BL concordance with the binary decision, whether non-irritant or irritant was estimated to be 85-95% and 95%, respectively. WL/BL reproducibility of viability data was further supported by a strong correlation(ICC, r>0.9). WL/BL agreement of binary decisions was also examined by Fleiss' Kappa statistics, which showed a strong level of agreement (>0.78), nevertheless weaker than the reproducibility of the viability. The EIT with MCTT HCE™ exhibited a sensitivity of 82.2% (60/73), a specificity of 81.1% (43/53), and an accuracy of 81.8% (103/126) for 126 reference substances (for liquids; a sensitivity of 100% (47/47), a specificity of 70.6% (24/34), and an accuracy of 87.7% (71/81), and for solids, a sensitivity of 50% (13/26), a specificity of 100% (19/19), and an accuracy of 71.1% (32/45), suggesting that the accuracy is satisfactory but the sensitivity needs improvement, which shall be addressed through correcting the poor sensitivity for solid substances in future full validation trials. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Pilot Testing of the EIT-4-BPSD Intervention.

    Science.gov (United States)

    Resnick, Barbara; Kolanowski, Ann; Van Haitsma, Kimberly; Boltz, Marie; Galik, Elizabeth; Bonner, Alice; Vigne, Erin; Holtzman, Lauren; Mulhall, Paula M

    2016-11-01

    Behavioral and psychological symptoms of dementia are common in nursing home residents, and the Centers for Medicare and Medicaid Services now require that nonpharmacological interventions be used as a first-line treatment. Few staff know how to implement these interventions. The purpose of this study was to pilot test an implementation strategy, Evidence Integration Triangle for Behavioral and Psychological Symptoms of Dementia (EIT-4-BPSD), which was developed to help staff integrate behavioral interventions into routine care. The EIT-4-BPSD was implemented in 2 nursing homes, and 21 residents were recruited. A research nurse facilitator worked with facility champions and a stakeholder team to implement the 4 steps of EIT-4-BPSD. There was evidence of reach to all staff; effectiveness with improvement in residents' quality of life and a decrease in agitation; adoption based on the environment, policy, and care plan changes; and implementation and plans for maintenance beyond the 6-month intervention period. © The Author(s) 2016.

  9. Evaluation of EIT system performance.

    Science.gov (United States)

    Yasin, Mamatjan; Böhm, Stephan; Gaggero, Pascal O; Adler, Andy

    2011-07-01

    An electrical impedance tomography (EIT) system images internal conductivity from surface electrical stimulation and measurement. Such systems necessarily comprise multiple design choices from cables and hardware design to calibration and image reconstruction. In order to compare EIT systems and study the consequences of changes in system performance, this paper describes a systematic approach to evaluate the performance of the EIT systems. The system to be tested is connected to a saline phantom in which calibrated contrasting test objects are systematically positioned using a position controller. A set of evaluation parameters are proposed which characterize (i) data and image noise, (ii) data accuracy, (iii) detectability of single contrasts and distinguishability of multiple contrasts, and (iv) accuracy of reconstructed image (amplitude, resolution, position and ringing). Using this approach, we evaluate three different EIT systems and illustrate the use of these tools to evaluate and compare performance. In order to facilitate the use of this approach, all details of the phantom, test objects and position controller design are made publicly available including the source code of the evaluation and reporting software.

  10. The evaluation of the local tolerance of vaginal formulations containing dapivirine using the Slug Mucosal Irritation test and the rabbit vaginal irritation test.

    Science.gov (United States)

    Dhondt, Marijke M M; Adriaens, Els; Roey, Jens Van; Remon, Jean Paul

    2005-08-01

    The purpose of this study was to evaluate the local tolerance of vaginal gels (three gels containing dapivirine, the placebo gel, and Conceptrol) with the Slug Mucosal Irritation test and to compare the results with those of the rabbit vaginal irritation test. The irritation potential on the slug mucosa was assessed by the mucus production caused by a repeated treatment for 5 successive days. Additionally, membrane damage was estimated by the protein and enzyme release. By means of a classification prediction model the formulations were classified into four irritation classes. The effect of a 10-day intravaginal application of the gels on the rabbit vaginal and cervical mucosa was evaluated by means of macroscopic and microscopic examination. The placebo and dapivirine gels induced no irritation of the slug mucosa (low mucus production and protein release, no enzyme release) and no vaginal or cervical irritation in rabbits. Conceptrol caused severe irritation of the slug mucosa (increased mucus production, protein release, and enzyme release) and irritation of the rabbit vagina and cervix. The results obtained with the Slug Mucosal Irritation test were comparable to those of the rabbit vaginal irritation test.

  11. EIT-based fabric pressure sensing.

    Science.gov (United States)

    Yao, A; Yang, C L; Seo, J K; Soleimani, M

    2013-01-01

    This paper presents EIT-based fabric sensors that aim to provide a pressure mapping using the current carrying and voltage sensing electrodes attached to the boundary of the fabric patch. Pressure-induced shape change over the sensor area makes a change in the conductivity distribution which can be conveyed to the change of boundary current-voltage data. This boundary data is obtained through electrode measurements in EIT system. The corresponding inverse problem is to reconstruct the pressure and deformation map from the relationship between the applied current and the measured voltage on the fabric boundary. Taking advantage of EIT in providing dynamical images of conductivity changes due to pressure induced shape change, the pressure map can be estimated. In this paper, the EIT-based fabric sensor was presented for circular and rectangular sensor geometry. A stretch sensitive fabric was used in circular sensor with 16 electrodes and a pressure sensitive fabric was used in a rectangular sensor with 32 electrodes. A preliminary human test was carried out with the rectangular sensor for foot pressure mapping showing promising results.

  12. EIT-Based Fabric Pressure Sensing

    Directory of Open Access Journals (Sweden)

    A. Yao

    2013-01-01

    Full Text Available This paper presents EIT-based fabric sensors that aim to provide a pressure mapping using the current carrying and voltage sensing electrodes attached to the boundary of the fabric patch. Pressure-induced shape change over the sensor area makes a change in the conductivity distribution which can be conveyed to the change of boundary current-voltage data. This boundary data is obtained through electrode measurements in EIT system. The corresponding inverse problem is to reconstruct the pressure and deformation map from the relationship between the applied current and the measured voltage on the fabric boundary. Taking advantage of EIT in providing dynamical images of conductivity changes due to pressure induced shape change, the pressure map can be estimated. In this paper, the EIT-based fabric sensor was presented for circular and rectangular sensor geometry. A stretch sensitive fabric was used in circular sensor with 16 electrodes and a pressure sensitive fabric was used in a rectangular sensor with 32 electrodes. A preliminary human test was carried out with the rectangular sensor for foot pressure mapping showing promising results.

  13. Alternative methods for skin irritation testing: the current status : ECVAM skin irritation task force report 1

    NARCIS (Netherlands)

    Botham, P.A.; Earl, L.K.; Fentem, J.H.; Roguet, R.; Sandt, J.J.M.

    1998-01-01

    The ECVAM Skin Irritation Task Force was established in November 1996, primarily to prepare a report on the current status of the development and validation of alternative tests for skin irritation and corrosion and, in particular, to identify any appropriate non-animal tests for predicting human

  14. Solar Phenomena Associated with "EIT Waves"

    Science.gov (United States)

    Biesecker, D. A.; Myers, D. C.; Thompson, B. J.; Hammer, D. M.; Vourlidas, A.

    2002-01-01

    In an effort to understand what an 'EIT wave' is and what its causes are, we have looked for correlations between the initiation of EIT waves and the occurrence of other solar phenomena. An EIT wave is a coronal disturbance, typically appearing as a diffuse brightening propagating across the Sun. A catalog of EIT waves, covering the period from 1997 March through 1998 June, was used in this study. For each EIT wave, the catalog gives the heliographic location and a rating for each wave, where the rating is determined by the reliability of the observations. Since EIT waves are transient, coronal phenomena, we have looked for correlations with other transient, coronal phenomena: X-ray flares, coronal mass ejections (CMEs), and metric type II radio bursts. An unambiguous correlation between EIT waves and CMEs has been found. The correlation of EIT waves with flares is significantly weaker, and EIT waves frequently are not accompanied by radio bursts. To search for trends in the data, proxies for each of these transient phenomena are examined. We also use the accumulated data to show the robustness of the catalog and to reveal biases that must be accounted for in this study.

  15. Histological distinction between early allergic and irritant patch test reactions

    DEFF Research Database (Denmark)

    Vestergaard, L; Clemmensen, Ole; Sørensen, Flemming Brandt

    1999-01-01

    no recognizable changes except a slight follicular spongiosis in 1 patient. The 2 pathologists agreed independently on the correct classification in 6 out of 7 cases (p=0.0156). We tested an optimized model, selecting non-irritant allergens and a well-known irritant. Further investigations are needed to elucidate......Comparative light microscopic studies have revealed subtle differences between allergic and irritant reactions in the skin. In the search for specific differences, we focussed on the early inflammatory response. This pilot study was conducted to test the hypothesis that follicular spongiosis can...... differentiate between early allergic and irritant patch test reactions. 8 patients with known contact allergy to either colophony or quarternium-15 participated in the study. In each patient, allergic and irritant patch tests reactions were elicited, and 4-mm punch biopsies were taken after 6 8 h from...

  16. Applications of Electrical Impedance Tomography (EIT): A Short Review

    Science.gov (United States)

    Kanti Bera, Tushar

    2018-03-01

    Electrical Impedance Tomography (EIT) is a tomographic imaging method which solves an ill posed inverse problem using the boundary voltage-current data collected from the surface of the object under test. Though the spatial resolution is comparatively low compared to conventional tomographic imaging modalities, due to several advantages EIT has been studied for a number of applications such as medical imaging, material engineering, civil engineering, biotechnology, chemical engineering, MEMS and other fields of engineering and applied sciences. In this paper, the applications of EIT have been reviewed and presented as a short summary. The working principal, instrumentation and advantages are briefly discussed followed by a detail discussion on the applications of EIT technology in different areas of engineering, technology and applied sciences.

  17. Histological distinction between early allergic and irritant patch test reactions

    DEFF Research Database (Denmark)

    Vestergaard, L; Clemmensen, Ole; Sørensen, Flemming Brandt

    1999-01-01

    Comparative light microscopic studies have revealed subtle differences between allergic and irritant reactions in the skin. In the search for specific differences, we focussed on the early inflammatory response. This pilot study was conducted to test the hypothesis that follicular spongiosis can...... differentiate between early allergic and irritant patch test reactions. 8 patients with known contact allergy to either colophony or quarternium-15 participated in the study. In each patient, allergic and irritant patch tests reactions were elicited, and 4-mm punch biopsies were taken after 6 8 h from...... clinically equipotent reactions. Paired sets of slides were assessed blindly by 2 pathologists. 1 patient showing a pityrosporum folliculitis was excluded from the study. All biopsies from allergic patch tests were characterized by follicular spongiosis, while biopsies from irritant patch tests showed...

  18. Extreme Ultraviolet Imaging Telescope (EIT)

    Science.gov (United States)

    Lemen, J. R.; Freeland, S. L.

    1997-01-01

    Efforts concentrated on development and implementation of the SolarSoft (SSW) data analysis system. From an EIT analysis perspective, this system was designed to facilitate efficient reuse and conversion of software developed for Yohkoh/SXT and to take advantage of a large existing body of software developed by the SDAC, Yohkoh, and SOHO instrument teams. Another strong motivation for this system was to provide an EIT analysis environment which permits coordinated analysis of EIT data in conjunction with data from important supporting instruments, including Yohkoh/SXT and the other SOHO coronal instruments; CDS, SUMER, and LASCO. In addition, the SSW system will support coordinated EIT/TRACE analysis (by design) when TRACE data is available; TRACE launch is currently planned for March 1998. Working with Jeff Newmark, the Chianti software package (K.P. Dere et al) and UV /EUV data base was fully integrated into the SSW system to facilitate EIT temperature and emission analysis.

  19. 3D EIT image reconstruction with GREIT.

    Science.gov (United States)

    Grychtol, Bartłomiej; Müller, Beat; Adler, Andy

    2016-06-01

    Most applications of thoracic EIT use a single plane of electrodes on the chest from which a transverse image 'slice' is calculated. However, interpretation of EIT images is made difficult by the large region above and below the electrode plane to which EIT is sensitive. Volumetric EIT images using two (or more) electrode planes should help compensate, but are little used currently. The Graz consensus reconstruction algorithm for EIT (GREIT) has become popular in lung EIT. One shortcoming of the original formulation of GREIT is its restriction to reconstruction onto a 2D planar image. We present an extension of the GREIT algorithm to 3D and develop open-source tools to evaluate its performance as a function of the choice of stimulation and measurement pattern. Results show 3D GREIT using two electrode layers has significantly more uniform sensitivity profiles through the chest region. Overall, the advantages of 3D EIT are compelling.

  20. Comparison of different functional EIT approaches to quantify tidal ventilation distribution.

    Science.gov (United States)

    Zhao, Zhanqi; Yun, Po-Jen; Kuo, Yen-Liang; Fu, Feng; Dai, Meng; Frerichs, Inez; Möller, Knut

    2018-01-30

    The aim of the study was to examine the pros and cons of different types of functional EIT (fEIT) to quantify tidal ventilation distribution in a clinical setting. fEIT images were calculated with (1) standard deviation of pixel time curve, (2) regression coefficients of global and local impedance time curves, or (3) mean tidal variations. To characterize temporal heterogeneity of tidal ventilation distribution, another fEIT image of pixel inspiration times is also proposed. fEIT-regression is very robust to signals with different phase information. When the respiratory signal should be distinguished from the heart-beat related signal, or during high-frequency oscillatory ventilation, fEIT-regression is superior to other types. fEIT-tidal variation is the most stable image type regarding the baseline shift. We recommend using this type of fEIT image for preliminary evaluation of the acquired EIT data. However, all these fEITs would be misleading in their assessment of ventilation distribution in the presence of temporal heterogeneity. The analysis software provided by the currently available commercial EIT equipment only offers either fEIT of standard deviation or tidal variation. Considering the pros and cons of each fEIT type, we recommend embedding more types into the analysis software to allow the physicians dealing with more complex clinical applications with on-line EIT measurements.

  1. Flexible electrode belt for EIT using nanofiber web dry electrodes.

    Science.gov (United States)

    Oh, Tong In; Kim, Tae Eui; Yoon, Sun; Kim, Kap Jin; Woo, Eung Je; Sadleir, Rosalind J

    2012-10-01

    Efficient connection of multiple electrodes to the body for impedance measurement and voltage monitoring applications is of critical importance to measurement quality and practicality. Electrical impedance tomography (EIT) experiments have generally required a cumbersome procedure to attach the multiple electrodes needed in EIT. Once placed, these electrodes must then maintain good contact with the skin during measurements that may last several hours. There is usually also the need to manage the wires that run between the electrodes and the EIT system. These problems become more severe as the number of electrodes increases, and may limit the practicality and portability of this imaging method. There have been several trials describing human-electrode interfaces using configurations such as electrode belts, helmets or rings. In this paper, we describe an electrode belt we developed for long-term EIT monitoring of human lung ventilation. The belt included 16 embossed electrodes that were designed to make good contact with the skin. The electrodes were fabricated using an Ag-plated PVDF nanofiber web and metallic threads. A large contact area and padding were used behind each electrode to improve subject comfort and reduce contact impedances. The electrodes were incorporated, equally spaced, into an elasticated fabric belt. We tested the electrode belt in conjunction with the KHU Mark1 multi-frequency EIT system, and demonstrate time-difference images of phantoms and human subjects during normal breathing and running. We found that the Ag-plated PVDF nanofiber web electrodes were suitable for long-term measurement because of their flexibility and durability. Moreover, the contact impedance and stability of the Ag-plated PVDF nanofiber web electrodes were found to be comparable to similarly tested Ag/AgCl electrodes.

  2. EIT image reconstruction with four dimensional regularization.

    Science.gov (United States)

    Dai, Tao; Soleimani, Manuchehr; Adler, Andy

    2008-09-01

    Electrical impedance tomography (EIT) reconstructs internal impedance images of the body from electrical measurements on body surface. The temporal resolution of EIT data can be very high, although the spatial resolution of the images is relatively low. Most EIT reconstruction algorithms calculate images from data frames independently, although data are actually highly correlated especially in high speed EIT systems. This paper proposes a 4-D EIT image reconstruction for functional EIT. The new approach is developed to directly use prior models of the temporal correlations among images and 3-D spatial correlations among image elements. A fast algorithm is also developed to reconstruct the regularized images. Image reconstruction is posed in terms of an augmented image and measurement vector which are concatenated from a specific number of previous and future frames. The reconstruction is then based on an augmented regularization matrix which reflects the a priori constraints on temporal and 3-D spatial correlations of image elements. A temporal factor reflecting the relative strength of the image correlation is objectively calculated from measurement data. Results show that image reconstruction models which account for inter-element correlations, in both space and time, show improved resolution and noise performance, in comparison to simpler image models.

  3. THE RELATION BETWEEN EIT WAVES AND CORONAL MASS EJECTIONS

    International Nuclear Information System (INIS)

    Chen, P. F.

    2009-01-01

    More and more evidence indicates that 'EIT waves' are strongly related to coronal mass ejections (CMEs). However, it is still not clear how the two phenomena are related to each other. We investigate a CME event on 1997 September 9, which was well observed by both the EUV Imaging Telescope (EIT) and the high-cadence Mark-III K-Coronameter at Mauna Loa Solar Observatory, and compare the spatial relation between the 'EIT wave' fronts and the CME leading loops. It is found that 'EIT wave' fronts are cospatial with the CME leading loops, and the expanding EUV dimmings are cospatial with the CME cavity. It is also found that the CME stopped near the boundary of a coronal hole, a feature common to observations of 'EIT waves'. It is suggested that 'EIT waves'/dimmings are the EUV counterparts of the CME leading loop/cavity, based on which we propose that, as in the case of 'EIT waves', CME leading loops are apparently moving density enhancements that are generated by successive stretching (or opening-up) of magnetic loops.

  4. Anti-irritants I: Dose-response in acute irritation

    DEFF Research Database (Denmark)

    Andersen, Flemming; Hedegaard, Kathryn; Petersen, Thomas Kongstad

    2006-01-01

    acute irritation in healthy volunteers. Each AI was used in 3 concentrations. Acute irritation was induced by occlusive tests with 1% sodium lauryl sulfate and 20% nonanoic acid in N-propanol. The irritant reactions were treated twice daily with AI-containing formulations from the time of removal...

  5. Phenomena Associated With EIT Waves

    Science.gov (United States)

    Thompson, B. J.; Biesecker, D. A.; Gopalswamy, N.

    2003-01-01

    We discuss phenomena associated with "EIT Wave" transients. These phenomena include coronal mass ejections, flares, EUV/SXR dimmings, chromospheric waves, Moreton waves, solar energetic particle events, energetic electron events, and radio signatures. Although the occurrence of many phenomena correlate with the appearance of EIT waves, it is difficult to mfer which associations are causal. The presentation will include a discussion of correlation surveys of these phenomena.

  6. The influence of image reconstruction algorithms on linear thorax EIT image analysis of ventilation

    International Nuclear Information System (INIS)

    Zhao, Zhanqi; Möller, Knut; Frerichs, Inéz; Pulletz, Sven; Müller-Lisse, Ullrich

    2014-01-01

    Analysis methods of electrical impedance tomography (EIT) images based on different reconstruction algorithms were examined. EIT measurements were performed on eight mechanically ventilated patients with acute respiratory distress syndrome. A maneuver with step increase of airway pressure was performed. EIT raw data were reconstructed offline with (1) filtered back-projection (BP); (2) the Dräger algorithm based on linearized Newton–Raphson (DR); (3) the GREIT (Graz consensus reconstruction algorithm for EIT) reconstruction algorithm with a circular forward model (GR C ) and (4) GREIT with individual thorax geometry (GR T ). Individual thorax contours were automatically determined from the routine computed tomography images. Five indices were calculated on the resulting EIT images respectively: (a) the ratio between tidal and deep inflation impedance changes; (b) tidal impedance changes in the right and left lungs; (c) center of gravity; (d) the global inhomogeneity index and (e) ventilation delay at mid-dorsal regions. No significant differences were found in all examined indices among the four reconstruction algorithms (p > 0.2, Kruskal–Wallis test). The examined algorithms used for EIT image reconstruction do not influence the selected indices derived from the EIT image analysis. Indices that validated for images with one reconstruction algorithm are also valid for other reconstruction algorithms. (paper)

  7. The influence of image reconstruction algorithms on linear thorax EIT image analysis of ventilation.

    Science.gov (United States)

    Zhao, Zhanqi; Frerichs, Inéz; Pulletz, Sven; Müller-Lisse, Ullrich; Möller, Knut

    2014-06-01

    Analysis methods of electrical impedance tomography (EIT) images based on different reconstruction algorithms were examined. EIT measurements were performed on eight mechanically ventilated patients with acute respiratory distress syndrome. A maneuver with step increase of airway pressure was performed. EIT raw data were reconstructed offline with (1) filtered back-projection (BP); (2) the Dräger algorithm based on linearized Newton-Raphson (DR); (3) the GREIT (Graz consensus reconstruction algorithm for EIT) reconstruction algorithm with a circular forward model (GR(C)) and (4) GREIT with individual thorax geometry (GR(T)). Individual thorax contours were automatically determined from the routine computed tomography images. Five indices were calculated on the resulting EIT images respectively: (a) the ratio between tidal and deep inflation impedance changes; (b) tidal impedance changes in the right and left lungs; (c) center of gravity; (d) the global inhomogeneity index and (e) ventilation delay at mid-dorsal regions. No significant differences were found in all examined indices among the four reconstruction algorithms (p > 0.2, Kruskal-Wallis test). The examined algorithms used for EIT image reconstruction do not influence the selected indices derived from the EIT image analysis. Indices that validated for images with one reconstruction algorithm are also valid for other reconstruction algorithms.

  8. Future energy research in the EU under EIT conditions-pilot projects

    Energy Technology Data Exchange (ETDEWEB)

    Puehringer-Oppermann, Franziska; Bele, Petra; Bussar, Rainer; Stimming, Ulrich [TUM, Dept. of Physics, E19, James-Franck Str. 1, D-85748 Garching (Germany)

    2009-07-01

    The European Institute of Innovation and Technology (EIT) has been established in April 2008. It is an independent organisation with the administrative head in Budapest, a governing board, an executive committee and a chairman. The EIT budget until 2012 is 308 MEUR. EIT will operate through the formation of Knowledge and Innovation Communities (KICs). The first three KICs are foreseen in the areas sustainable energy, ICT and climate mitigation. The European Commission has sponsored four pilot projects (conducted 2008-2009) to help develop a suitable governance structure for cooperations on European scale such as the future KICs. They are Bridge, ComplexEIT, SUCCESS and Gast, dealing with different topics like nanomedicine (Bridge), integration of hardware and software (ComplexEIT), sustainable energy (SUCCESS) and green and safe road transportation (Gast). The strategic objective of these pilot projects is to design, implement and test new models of cooperation in the knowledge triangle. We are involved in SUCCESS and after benchmarking of 66 collaborations in the field sustainable energy, the state of the art of selected representative topics was asessed and shortcomings in governance evaluated by SWOT analysis. In parallel further existing collaborations were used to extract and establish a management structure for such collaborations on the European scale.

  9. Applicability of an exaggerated forearm wash test for efficacy testing of two corticosteroids, tacrolimus and glycerol, in topical formulations against skin irritation induced by two different irritants

    DEFF Research Database (Denmark)

    Clemmensen, A; Andersen, F; Petersen, T K

    2011-01-01

    applied, we tested the efficacy of four anti-irritant compounds using the two different irritants sodium lauryl sulfate (SLS) and nonanoic acid (NON). Methods: In a randomized, double-blind, controlled trial, healthy volunteers were exposed to 5% SLS and 50% NON (the right and the left forearm...

  10. Uniform background assumption produces misleading lung EIT images.

    Science.gov (United States)

    Grychtol, Bartłomiej; Adler, Andy

    2013-06-01

    Electrical impedance tomography (EIT) estimates an image of conductivity change within a body from stimulation and measurement at body surface electrodes. There is significant interest in EIT for imaging the thorax, as a monitoring tool for lung ventilation. To be useful in this application, we require an understanding of if and when EIT images can produce inaccurate images. In this paper, we study the consequences of the homogeneous background assumption, frequently made in linear image reconstruction, which introduces a mismatch between the reference measurement and the linearization point. We show in simulation and experimental data that the resulting images may contain large and clinically significant errors. A 3D finite element model of thorax conductivity is used to simulate EIT measurements for different heart and lung conductivity, size and position, as well as different amounts of gravitational collapse and ventilation-associated conductivity change. Three common linear EIT reconstruction algorithms are studied. We find that the asymmetric position of the heart can cause EIT images of ventilation to show up to 60% undue bias towards the left lung and that the effect is particularly strong for a ventilation distribution typical of mechanically ventilated patients. The conductivity gradient associated with gravitational lung collapse causes conductivity changes in non-dependent lung to be overestimated by up to 100% with respect to the dependent lung. Eliminating the mismatch by using a realistic conductivity distribution in the forward model of the reconstruction algorithm strongly reduces these undesirable effects. We conclude that subject-specific anatomically accurate forward models should be used in lung EIT and extra care is required when analysing EIT images of subjects whose background conductivity distribution in the lungs is known to be heterogeneous or exhibiting large changes.

  11. Uniform background assumption produces misleading lung EIT images

    International Nuclear Information System (INIS)

    Grychtol, Bartłomiej; Adler, Andy

    2013-01-01

    Electrical impedance tomography (EIT) estimates an image of conductivity change within a body from stimulation and measurement at body surface electrodes. There is significant interest in EIT for imaging the thorax, as a monitoring tool for lung ventilation. To be useful in this application, we require an understanding of if and when EIT images can produce inaccurate images. In this paper, we study the consequences of the homogeneous background assumption, frequently made in linear image reconstruction, which introduces a mismatch between the reference measurement and the linearization point. We show in simulation and experimental data that the resulting images may contain large and clinically significant errors. A 3D finite element model of thorax conductivity is used to simulate EIT measurements for different heart and lung conductivity, size and position, as well as different amounts of gravitational collapse and ventilation-associated conductivity change. Three common linear EIT reconstruction algorithms are studied. We find that the asymmetric position of the heart can cause EIT images of ventilation to show up to 60% undue bias towards the left lung and that the effect is particularly strong for a ventilation distribution typical of mechanically ventilated patients. The conductivity gradient associated with gravitational lung collapse causes conductivity changes in non-dependent lung to be overestimated by up to 100% with respect to the dependent lung. Eliminating the mismatch by using a realistic conductivity distribution in the forward model of the reconstruction algorithm strongly reduces these undesirable effects. We conclude that subject-specific anatomically accurate forward models should be used in lung EIT and extra care is required when analysing EIT images of subjects whose background conductivity distribution in the lungs is known to be heterogeneous or exhibiting large changes. (paper)

  12. GREIT: a unified approach to 2D linear EIT reconstruction of lung images.

    Science.gov (United States)

    Adler, Andy; Arnold, John H; Bayford, Richard; Borsic, Andrea; Brown, Brian; Dixon, Paul; Faes, Theo J C; Frerichs, Inéz; Gagnon, Hervé; Gärber, Yvo; Grychtol, Bartłomiej; Hahn, Günter; Lionheart, William R B; Malik, Anjum; Patterson, Robert P; Stocks, Janet; Tizzard, Andrew; Weiler, Norbert; Wolf, Gerhard K

    2009-06-01

    Electrical impedance tomography (EIT) is an attractive method for clinically monitoring patients during mechanical ventilation, because it can provide a non-invasive continuous image of pulmonary impedance which indicates the distribution of ventilation. However, most clinical and physiological research in lung EIT is done using older and proprietary algorithms; this is an obstacle to interpretation of EIT images because the reconstructed images are not well characterized. To address this issue, we develop a consensus linear reconstruction algorithm for lung EIT, called GREIT (Graz consensus Reconstruction algorithm for EIT). This paper describes the unified approach to linear image reconstruction developed for GREIT. The framework for the linear reconstruction algorithm consists of (1) detailed finite element models of a representative adult and neonatal thorax, (2) consensus on the performance figures of merit for EIT image reconstruction and (3) a systematic approach to optimize a linear reconstruction matrix to desired performance measures. Consensus figures of merit, in order of importance, are (a) uniform amplitude response, (b) small and uniform position error, (c) small ringing artefacts, (d) uniform resolution, (e) limited shape deformation and (f) high resolution. Such figures of merit must be attained while maintaining small noise amplification and small sensitivity to electrode and boundary movement. This approach represents the consensus of a large and representative group of experts in EIT algorithm design and clinical applications for pulmonary monitoring. All software and data to implement and test the algorithm have been made available under an open source license which allows free research and commercial use.

  13. GREIT: a unified approach to 2D linear EIT reconstruction of lung images

    International Nuclear Information System (INIS)

    Adler, Andy; Arnold, John H; Bayford, Richard; Tizzard, Andrew; Borsic, Andrea; Brown, Brian; Dixon, Paul; Faes, Theo J C; Frerichs, Inéz; Weiler, Norbert; Gagnon, Hervé; Gärber, Yvo; Grychtol, Bartłomiej; Hahn, Günter; Lionheart, William R B; Malik, Anjum; Patterson, Robert P; Stocks, Janet; Wolf, Gerhard K

    2009-01-01

    Electrical impedance tomography (EIT) is an attractive method for clinically monitoring patients during mechanical ventilation, because it can provide a non-invasive continuous image of pulmonary impedance which indicates the distribution of ventilation. However, most clinical and physiological research in lung EIT is done using older and proprietary algorithms; this is an obstacle to interpretation of EIT images because the reconstructed images are not well characterized. To address this issue, we develop a consensus linear reconstruction algorithm for lung EIT, called GREIT (Graz consensus Reconstruction algorithm for EIT). This paper describes the unified approach to linear image reconstruction developed for GREIT. The framework for the linear reconstruction algorithm consists of (1) detailed finite element models of a representative adult and neonatal thorax, (2) consensus on the performance figures of merit for EIT image reconstruction and (3) a systematic approach to optimize a linear reconstruction matrix to desired performance measures. Consensus figures of merit, in order of importance, are (a) uniform amplitude response, (b) small and uniform position error, (c) small ringing artefacts, (d) uniform resolution, (e) limited shape deformation and (f) high resolution. Such figures of merit must be attained while maintaining small noise amplification and small sensitivity to electrode and boundary movement. This approach represents the consensus of a large and representative group of experts in EIT algorithm design and clinical applications for pulmonary monitoring. All software and data to implement and test the algorithm have been made available under an open source license which allows free research and commercial use

  14. Positioning of electrode plane systematically influences EIT imaging.

    Science.gov (United States)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Müller-Lisse, Ullrich; Möller, Knut; Zhao, Zhanqi

    2015-06-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔIERV/ERV, ΔIVT/VT and ΔIIRV/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔIERV/ERV ratio in all subjects was significantly higher than the normalized ΔIIRV/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions.

  15. Positioning of electrode plane systematically influences EIT imaging

    International Nuclear Information System (INIS)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Möller, Knut; Zhao, Zhanqi; Müller-Lisse, Ullrich

    2015-01-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔI_E_R_V/ERV, ΔI_V_T/VT and ΔI_I_R_V/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔI_E_R_V/ERV ratio in all subjects was significantly higher than the normalized ΔI_I_R_V/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions. (paper)

  16. Choice of reconstructed tissue properties affects interpretation of lung EIT images.

    Science.gov (United States)

    Grychtol, Bartłomiej; Adler, Andy

    2014-06-01

    Electrical impedance tomography (EIT) estimates an image of change in electrical properties within a body from stimulations and measurements at surface electrodes. There is significant interest in EIT as a tool to monitor and guide ventilation therapy in mechanically ventilated patients. In lung EIT, the EIT inverse problem is commonly linearized and only changes in electrical properties are reconstructed. Early algorithms reconstructed changes in resistivity, while most recent work using the finite element method reconstructs conductivity. Recently, we demonstrated that EIT images of ventilation can be misleading if the electrical contrasts within the thorax are not taken into account during the image reconstruction process. In this paper, we explore the effect of the choice of the reconstructed electrical properties (resistivity or conductivity) on the resulting EIT images. We show in simulation and experimental data that EIT images reconstructed with the same algorithm but with different parametrizations lead to large and clinically significant differences in the resulting images, which persist even after attempts to eliminate the impact of the parameter choice by recovering volume changes from the EIT images. Since there is no consensus among the most popular reconstruction algorithms and devices regarding the parametrization, this finding has implications for potential clinical use of EIT. We propose a program of research to develop reconstruction techniques that account for both the relationship between air volume and electrical properties of the lung and artefacts introduced by the linearization.

  17. Choice of reconstructed tissue properties affects interpretation of lung EIT images

    International Nuclear Information System (INIS)

    Grychtol, Bartłomiej; Adler, Andy

    2014-01-01

    Electrical impedance tomography (EIT) estimates an image of change in electrical properties within a body from stimulations and measurements at surface electrodes. There is significant interest in EIT as a tool to monitor and guide ventilation therapy in mechanically ventilated patients. In lung EIT, the EIT inverse problem is commonly linearized and only changes in electrical properties are reconstructed. Early algorithms reconstructed changes in resistivity, while most recent work using the finite element method reconstructs conductivity. Recently, we demonstrated that EIT images of ventilation can be misleading if the electrical contrasts within the thorax are not taken into account during the image reconstruction process. In this paper, we explore the effect of the choice of the reconstructed electrical properties (resistivity or conductivity) on the resulting EIT images. We show in simulation and experimental data that EIT images reconstructed with the same algorithm but with different parametrizations lead to large and clinically significant differences in the resulting images, which persist even after attempts to eliminate the impact of the parameter choice by recovering volume changes from the EIT images. Since there is no consensus among the most popular reconstruction algorithms and devices regarding the parametrization, this finding has implications for potential clinical use of EIT. We propose a program of research to develop reconstruction techniques that account for both the relationship between air volume and electrical properties of the lung and artefacts introduced by the linearization. (paper)

  18. Synchronous absolute EIT in three thoracic planes at different gravity levels

    International Nuclear Information System (INIS)

    Hahn, G; Just, A; Dittmar, J; Fromm, K H; Quintel, M

    2013-01-01

    The validity of absolute Electrical Impedance Tomography (a-EIT) for assessment of local lung volume has been investigated far less than the well evaluated ventilation monitoring by functional EIT (f-EIT). To achieve progress in a-EIT we investigated 10 healthy volunteers in an upright sitting position by using a-EIT at normal gravity (1 g), weightlessness (0 g) and approx. double gravity (1.8 g) during parabolic flight manoeuvres. Lung resistivity in three thoracic planes was determined by a-EIT using a multiple-plane synchronised Goe-MF II EIT system. Tomograms of resistivity at end-expiration in normal spontaneous breathing were reconstructed by a modified SIRT algorithm. Local lung resistivity was determined separately for both lungs. The respective resistivity values at 1 g and 1.8 g before and after weightlessness show an almost reversible behaviour along the sequence of gravity changes with a tendency to be lower after occurrence of weightlessness. The results reveal not only the expected varying resistivity of lung tissue in cranio-caudal direction but also a clear difference in these cranio-caudal stratifications of local lung volume between the left and right lung. The resolution and stability of absolute EIT seem to be valid and expressive for future investigations of unilateral lung volume under different physiological and pathological conditions.

  19. Non-occlusive topical exposure of human skin in vitro as model for cytotoxicity testing of irritant compounds.

    Science.gov (United States)

    Lönnqvist, Susanna; Briheim, Kristina; Kratz, Gunnar

    2016-02-01

    Testing of irritant compounds has traditionally been performed on animals and human volunteers. Animal testing should always be restricted and for skin irritancy mice and rabbits hold poor predictive value for irritant potential in humans. Irritant testing on human volunteers is restricted by the duration subjects can be exposed, and by the subjectivity of interpreting the visual signs of skin irritation. We propose an irritant testing system using viable human full thickness skin with the loss of cell viability in the exposed skin area as end point measurement. Skin was exposed to sodium dodecyl sulfate (SDS) at 20% concentration by non-occluded topical exposure to establish a positive control response and subsequent test compounds were statistically compared with the 20% SDS response. Cell viability and metabolism were measured with 3-(4,5-dimethyl-thiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. The model presents correlation between increased concentration of SDS and decreased viability of cells in the exposed skin area (R(2) = 0.76). We propose the model to be used for cytotoxicity testing of irritant compounds. With fully intact barrier function, the model comprises all cells present in the skin with quantifiable end point measurement.

  20. Irritancy ranking of anionic detergents using one-time occlusive, repeated occlusive and repeated open tests

    NARCIS (Netherlands)

    Tupker, RA; Bunte, EE; Fidler, [No Value; Wiechers, JW; Coenraads, PJ

    Discrepancies between the one-time patch test and the wash test regarding the ranking of irritancy of detergents have been found in the literature. The aim of the present study was to investigate the concordance of irritancy rank order of 4 anionic detergents tested by 3 different exposure methods,

  1. Eye Irritation Test of Bovis Calculus Pharmacopuncture Solutions for Eye Drop

    Directory of Open Access Journals (Sweden)

    Hyeong-sik Seo

    2008-06-01

    Full Text Available Objective : This study was done to investigate the safety of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods : The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration (2005. 10. 21, KFDA 2005-60. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results : 1. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn’t physical problem at 9 rabbits. 2. After Bovis Calculus pharmacopuncture solutionwas medicated in the left eye of the rabbits, there wasn’t eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions : I suggested that Bovis Calculus pharmacopuncture solution didn’t induced eye irritation in rabbits.

  2. Understanding the Physical Nature of Coronal "EIT Waves".

    Science.gov (United States)

    Long, D M; Bloomfield, D S; Chen, P F; Downs, C; Gallagher, P T; Kwon, R-Y; Vanninathan, K; Veronig, A M; Vourlidas, A; Vršnak, B; Warmuth, A; Žic, T

    2017-01-01

    For almost 20 years the physical nature of globally propagating waves in the solar corona (commonly called "EIT waves") has been controversial and subject to debate. Additional theories have been proposed over the years to explain observations that did not agree with the originally proposed fast-mode wave interpretation. However, the incompatibility of observations made using the Extreme-ultraviolet Imaging Telescope (EIT) onboard the Solar and Heliospheric Observatory with the fast-mode wave interpretation was challenged by differing viewpoints from the twin Solar Terrestrial Relations Observatory spacecraft and data with higher spatial and temporal resolution from the Solar Dynamics Observatory . In this article, we reexamine the theories proposed to explain EIT waves to identify measurable properties and behaviours that can be compared to current and future observations. Most of us conclude that the so-called EIT waves are best described as fast-mode large-amplitude waves or shocks that are initially driven by the impulsive expansion of an erupting coronal mass ejection in the low corona.

  3. Skin irritability to sodium lauryl sulfate is associated with increased positive patch test reactions.

    Science.gov (United States)

    Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W

    2014-07-01

    As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.

  4. A new 3D reconstituted human corneal epithelium model as an alternative method for the eye irritation test.

    Science.gov (United States)

    Jung, Kyoung-Mi; Lee, Su-Hyon; Ryu, Yang-Hwan; Jang, Won-Hee; Jung, Haeng-Sun; Han, Ju-Hee; Seok, Seung-Hyeok; Park, Jae-Hak; Son, Youngsook; Park, Young-Ho; Lim, Kyung-Min

    2011-02-01

    Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  6. Aortic blood pressure measured via EIT: investigation of different measurement settings

    International Nuclear Information System (INIS)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Solà, Josep; Adler, Andy; Grychtol, Bartłomiej; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss–Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss–Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg. (paper)

  7. Non-Animal Testing Approach to EPA Labeling for Eye Irritation

    Science.gov (United States)

    This document is an update to EPA’s 2013 published alternative testing approach (using in vitro/ex vivo assays) for determination of eye irritation potential in the pesticide program under EPA's classification and labeling system.

  8. Systematic errors of EIT systems determined by easily-scalable resistive phantoms.

    Science.gov (United States)

    Hahn, G; Just, A; Dittmar, J; Hellige, G

    2008-06-01

    We present a simple method to determine systematic errors that will occur in the measurements by EIT systems. The approach is based on very simple scalable resistive phantoms for EIT systems using a 16 electrode adjacent drive pattern. The output voltage of the phantoms is constant for all combinations of current injection and voltage measurements and the trans-impedance of each phantom is determined by only one component. It can be chosen independently from the input and output impedance, which can be set in order to simulate measurements on the human thorax. Additional serial adapters allow investigation of the influence of the contact impedance at the electrodes on resulting errors. Since real errors depend on the dynamic properties of an EIT system, the following parameters are accessible: crosstalk, the absolute error of each driving/sensing channel and the signal to noise ratio in each channel. Measurements were performed on a Goe-MF II EIT system under four different simulated operational conditions. We found that systematic measurement errors always exceeded the error level of stochastic noise since the Goe-MF II system had been optimized for a sufficient signal to noise ratio but not for accuracy. In time difference imaging and functional EIT (f-EIT) systematic errors are reduced to a minimum by dividing the raw data by reference data. This is not the case in absolute EIT (a-EIT) where the resistivity of the examined object is determined on an absolute scale. We conclude that a reduction of systematic errors has to be one major goal in future system design.

  9. Systematic errors of EIT systems determined by easily-scalable resistive phantoms

    International Nuclear Information System (INIS)

    Hahn, G; Just, A; Dittmar, J; Hellige, G

    2008-01-01

    We present a simple method to determine systematic errors that will occur in the measurements by EIT systems. The approach is based on very simple scalable resistive phantoms for EIT systems using a 16 electrode adjacent drive pattern. The output voltage of the phantoms is constant for all combinations of current injection and voltage measurements and the trans-impedance of each phantom is determined by only one component. It can be chosen independently from the input and output impedance, which can be set in order to simulate measurements on the human thorax. Additional serial adapters allow investigation of the influence of the contact impedance at the electrodes on resulting errors. Since real errors depend on the dynamic properties of an EIT system, the following parameters are accessible: crosstalk, the absolute error of each driving/sensing channel and the signal to noise ratio in each channel. Measurements were performed on a Goe-MF II EIT system under four different simulated operational conditions. We found that systematic measurement errors always exceeded the error level of stochastic noise since the Goe-MF II system had been optimized for a sufficient signal to noise ratio but not for accuracy. In time difference imaging and functional EIT (f-EIT) systematic errors are reduced to a minimum by dividing the raw data by reference data. This is not the case in absolute EIT (a-EIT) where the resistivity of the examined object is determined on an absolute scale. We conclude that a reduction of systematic errors has to be one major goal in future system design

  10. Noninvasive pulmonary artery pressure monitoring by EIT: a model-based feasibility study.

    Science.gov (United States)

    Proença, Martin; Braun, Fabian; Solà, Josep; Thiran, Jean-Philippe; Lemay, Mathieu

    2017-06-01

    Current monitoring modalities for patients with pulmonary hypertension (PH) are limited to invasive solutions. A novel approach for the noninvasive and unsupervised monitoring of pulmonary artery pressure (PAP) in patients with PH was proposed and investigated. The approach was based on the use of electrical impedance tomography (EIT), a noninvasive and safe monitoring technique, and was tested through simulations on a realistic 4D bio-impedance model of the human thorax. Changes in PAP were induced in the model by simulating multiple types of hypertensive conditions. A timing parameter physiologically linked to the PAP via the so-called pulse wave velocity principle was automatically estimated from the EIT data. It was found that changes in PAP could indeed be reliably monitored by EIT, irrespective of the pathophysiological condition that caused them. If confirmed clinically, these findings could open the way for a new generation of noninvasive PAP monitoring solutions for the follow-up of patients with PH.

  11. Effects of different base agents on prediction of skin irritation by sodium lauryl sulfate using patch testing and repeated application test.

    Science.gov (United States)

    Horita, Kotomi; Horita, Daisuke; Tomita, Hiroyuki; Yasoshima, Mitsue; Yagami, Akiko; Matsunaga, Kayoko

    2017-05-01

    Animal testing for cosmetics was banned in the European Union (EU) in 2013; therefore, human tests to predict and ensure skin safety such as the patch test or usage test are now in demand in Japan as well as in the EU. In order to investigate the effects of different bases on the findings of tests to predict skin irritation, we performed patch testing (PT) and the repeated application test (RAT) using sodium lauryl sulfate (SLS), a well-known irritant, dissolved in 6 different base agents to examine the effects of these bases on skin irritation by SLS. The bases for PT were distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream. The concentrations of SLS were 0.2% and 0.5%. Twelve different base combinations were applied to the normal back skin of 19 individuals for 24h. RAT was performed with distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream containing SLS at concentrations of 0.2%, 2%, and 5%, being applied to the arms of the same PT subjects. The test preparation of each base was applied at the same site, with 0.2% SLS being used in the first week, 2% SLS in the following week, and 5% SLS in the final week. The results of PT revealed that skin irritation scores varied when SLS at the same concentration was dissolved in a different base. The results of RAT showed that although skin irritation appeared with every base at a concentration of 5%, the positive rate was approximately the same. In conclusion, our results suggest that skin irritation elicited in PT depends on the base, while in RAT, it does not depend on the type of base employed. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A stronger patch test elicitation reaction to the allergen hydroxycitronellal plus the irritant sodium lauryl sulfate

    DEFF Research Database (Denmark)

    Heydorn, S; Andersen, K E; Johansen, J D

    2003-01-01

    Household and cleaning products often contain both allergens and irritants. The aim of this double-blinded, randomized, paired study was to determine whether patch testing with an allergen (hydroxycitronellal) combined with an irritant [sodium lauryl sulfate (SLS)] cause a stronger patch test...

  13. Plasmonic EIT-like switching in bright-dark-bright plasmon resonators.

    Science.gov (United States)

    Chen, Junxue; Wang, Pei; Chen, Chuncong; Lu, Yonghua; Ming, Hai; Zhan, Qiwen

    2011-03-28

    In this paper we report the study of the electromagnetically induced transparency (EIT)-like transmission in the bright-dark-bright plasmon resonators. It is demonstrated that the interferences between the dark plasmons excited by two bright plasmon resonators can be controlled by the incident light polarization. The constructive interference strengthens the coupling between the bright and dark resonators, leading to a more prominent EIT-like transparency window of the metamaterial. In contrary, destructive interference suppresses the coupling between the bright and dark resonators, destroying the interference pathway that forms the EIT-like transmission. Based on this observation, the plasmonic EIT switching can be realized by changing the polarization of incident light. This phenomenon may find applications in optical switching and plasmon-based information processing.

  14. EIT Based Gas Detector Design by Using Michelson Interferometer

    International Nuclear Information System (INIS)

    Abbasian, K.; Rostami, A.; Abdollahi, M. H.

    2011-01-01

    Electromagnetically induced transparency (EIT) is one of the interesting phenomena of light-matter interaction which modifies matter properties for propagation of light. In other words, we can change the absorption and refractive index (RI) in neighborhood of the resonant frequency using EIT. In this paper, we have doped 3-level quantum dots in one of the Michelson Interferometer's mirror and used EIT to change its RI. So, a controllable phase difference between lights in two arms of interferometer is created. Long response time is the main drawback of Michelson interferometer based sensor, which is resolved by this technique.

  15. Irritancies of shampoos

    Directory of Open Access Journals (Sweden)

    Singh Sanjay

    1991-01-01

    Full Text Available Six commonly used shampoos were tested for their relative irritancies using Kligman and Wooding′s technique. Shampoos in increasing order of irritancies were Halo egg, Aqua dermis, Clinic plus, Sunsilk, Velvette black and Mediker.

  16. Compensation for large thorax excursions in EIT imaging.

    Science.gov (United States)

    Schullcke, B; Krueger-Ziolek, S; Gong, B; Mueller-Lisse, U; Moeller, K

    2016-09-01

    Besides the application of EIT in the intensive care unit it has recently also been used in spontaneously breathing patients suffering from asthma bronchiole, cystic fibrosis (CF) or chronic obstructive pulmonary disease (COPD). In these cases large thorax excursions during deep inspiration, e.g. during lung function testing, lead to artifacts in the reconstructed images. In this paper we introduce a new approach to compensate for image artifacts resulting from excursion induced changes in boundary voltages. It is shown in a simulation study that boundary voltage change due to thorax excursion on a homogeneous model can be used to modify the measured voltages and thus reduce the impact of thorax excursion on the reconstructed images. The applicability of the method on human subjects is demonstrated utilizing a motion-tracking-system. The proposed technique leads to fewer artifacts in the reconstructed images and improves image quality without substantial increase in computational effort, making the approach suitable for real-time imaging of lung ventilation. This might help to establish EIT as a supplemental tool for lung function tests in spontaneously breathing patients to support clinicians in diagnosis and monitoring of disease progression.

  17. Cumulative irritancy in the guinea pig from low grade irritant vehicles and the angry skin syndrome

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Maibach, H I

    1980-01-01

    A 4-week open cumulative irritancy test in guinea pigs discriminated between two low grade irritant vehicles, nonionic base (anhydrous) and hydrophilic ointment. The procedure might be useful as a predictive test for low grade irritants. The angry skin syndrome was established in the guinea pigs...

  18. EIT Course via Statewide TV

    Science.gov (United States)

    Marstrander, Jan H.; Talbot, Thomas F.

    1975-01-01

    Discusses the television broadcasting of a refresher course in mathematics and engineering fundamentals for those preparing to take the Engineer-in-Training (EIT) State Board Examination in Alabama. (MLH)

  19. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests.

    Science.gov (United States)

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2015-09-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).

  20. EIT and the Popular Imagination

    Science.gov (United States)

    Gurman, J. B.

    2005-01-01

    The Extreme ultraviolet Imaging Telescope on board SOHO, designed and built by Principal Investigator Jean-Pierre Delaboudiniere and his French/Belgan/US team, has produced numerous scientific breakthroughs, and has become both the standard coronal finder telescope and the determinant of whether halo coronal mass ejections are earthward-directed. Due to the dramatic nature of the images produced by EIT over the last nearly ten years, those images have been adopted worldwide in a manner no one could have foreseen before the launch of SOHO. I examine a small sample of the many scientific, commercial, and cultural uses of EIT imagery from the last decade in order to demonstrate how well-visualized, scientific imagery can first penetrate and then become an accepted part of the popular imagination.

  1. A Different Kind of Postgraduate Education. EIT's Educational Program for International Trainers.

    Science.gov (United States)

    Haslebo, Gitte; And Others

    EIT, or the European Institute for Transnational Studies in Group and Organisational Development, was founded in 1965 as a forum for international trainers in Europe. At present EIT has about 48 members, among which 7 are in the Scandinavian countries. EIT's most important tasks lie within the field of applied social psychology. After many years…

  2. A CATALOG OF CORONAL 'EIT WAVE' TRANSIENTS

    International Nuclear Information System (INIS)

    Thompson, B. J.; Myers, D. C.

    2009-01-01

    Solar and Heliospheric Observatory (SOHO) Extreme ultraviolet Imaging Telescope (EIT) data have been visually searched for coronal 'EIT wave' transients over the period beginning from 1997 March 24 and extending through 1998 June 24. The dates covered start at the beginning of regular high-cadence (more than 1 image every 20 minutes) observations, ending at the four-month interruption of SOHO observations in mid-1998. One hundred and seventy six events are included in this catalog. The observations range from 'candidate' events, which were either weak or had insufficient data coverage, to events which were well defined and were clearly distinguishable in the data. Included in the catalog are times of the EIT images in which the events are observed, diagrams indicating the observed locations of the wave fronts and associated active regions, and the speeds of the wave fronts. The measured speeds of the wave fronts varied from less than 50 to over 700 km s -1 with 'typical' speeds of 200-400 km s -1 .

  3. Towards lung EIT image segmentation: automatic classification of lung tissue state from analysis of EIT monitored recruitment manoeuvres

    International Nuclear Information System (INIS)

    Grychtol, Bartłomiej; Wolf, Gerhard K; Arnold, John H; Adler, Andy

    2010-01-01

    There is emerging evidence that the ventilation strategy used in acute lung injury (ALI) makes a significant difference in outcome and that an inappropriate ventilation strategy may produce ventilator-associated lung injury. Most harmful during mechanical ventilation are lung overdistension and lung collapse or atelectasis. Electrical impedance tomography (EIT) as a non-invasive imaging technology may be helpful to identify lung areas at risk. Currently, no automated method is routinely available to identify lung areas that are overdistended, collapsed or ventilated appropriately. We propose a fuzzy logic-based algorithm to analyse EIT images obtained during stepwise changes of mean airway pressures during mechanical ventilation. The algorithm is tested on data from two published studies of stepwise inflation–deflation manoeuvres in an animal model of ALI using conventional and high-frequency oscillatory ventilation. The timing of lung opening and collapsing on segmented images obtained using the algorithm during an inflation–deflation manoeuvre is in agreement with well-known effects of surfactant administration and changes in shunt fraction. While the performance of the algorithm has not been verified against a gold standard, we feel that it presents an important first step in tackling this challenging and important problem

  4. Towards lung EIT image segmentation: automatic classification of lung tissue state from analysis of EIT monitored recruitment manoeuvres.

    Science.gov (United States)

    Grychtol, Bartłomiej; Wolf, Gerhard K; Adler, Andy; Arnold, John H

    2010-08-01

    There is emerging evidence that the ventilation strategy used in acute lung injury (ALI) makes a significant difference in outcome and that an inappropriate ventilation strategy may produce ventilator-associated lung injury. Most harmful during mechanical ventilation are lung overdistension and lung collapse or atelectasis. Electrical impedance tomography (EIT) as a non-invasive imaging technology may be helpful to identify lung areas at risk. Currently, no automated method is routinely available to identify lung areas that are overdistended, collapsed or ventilated appropriately. We propose a fuzzy logic-based algorithm to analyse EIT images obtained during stepwise changes of mean airway pressures during mechanical ventilation. The algorithm is tested on data from two published studies of stepwise inflation-deflation manoeuvres in an animal model of ALI using conventional and high-frequency oscillatory ventilation. The timing of lung opening and collapsing on segmented images obtained using the algorithm during an inflation-deflation manoeuvre is in agreement with well-known effects of surfactant administration and changes in shunt fraction. While the performance of the algorithm has not been verified against a gold standard, we feel that it presents an important first step in tackling this challenging and important problem.

  5. Limitations and challenges of EIT-based monitoring of stroke volume and pulmonary artery pressure.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Lemay, Mathieu; Bertschi, Mattia; Adler, Andy; Thiran, Jean-Philippe; Solà, Josep

    2018-01-30

    Electrical impedance tomography (EIT) shows potential for radiation-free and noninvasive hemodynamic monitoring. However, many factors degrade the accuracy and repeatability of these measurements. Our goal is to estimate the impact of this variability on the EIT-based monitoring of two important central hemodynamic parameters: stroke volume (SV) and pulmonary artery pressure (PAP). We performed simulations on a 4D ([Formula: see text]) bioimpedance model of a human volunteer to study the influence of four potential confounding factors (electrode belt displacement, electrode detachment, changes in hematocrit and lung air volume) on the performance of EIT-based SV and PAP estimation. Results were used to estimate how these factors affect the EIT measures of either absolute values or relative changes (i.e. trending). Our findings reveal that the absolute measurement of SV via EIT is very sensitive to electrode belt displacements and lung conductivity changes. Nonetheless, the trending ability of SV EIT might be a promising alternative. The timing-based measurement of PAP is more robust to lung conductivity changes but sensitive to longitudinal belt displacements at severe hypertensive levels and to rotational displacements (independent of the PAP level). We identify and quantify the challenges of EIT-based SV and PAP monitoring. Absolute SV via EIT is challenging, but trending is feasible, while both the absolute and trending of PAP via EIT are mostly impaired by belt displacements.

  6. Ultranarrow-bandwidth filter based on a thermal EIT medium.

    Science.gov (United States)

    Wang, Gang; Wang, Yu-Sheng; Huang, Emily Kay; Hung, Weilun; Chao, Kai-Lin; Wu, Ping-Yeh; Chen, Yi-Hsin; Yu, Ite A

    2018-05-21

    We present high-contrast electromagnetically-induced-transparency (EIT) spectra in a heated vapor cell of single isotope 87 Rb atoms. The EIT spectrum has both high resonant transmission up to 67% and narrow linewidth of 1.1 MHz. We get rid of the possible amplification resulted from the effects of amplification without population inversion and four-wave mixing. Therefore, this high transmitted light is not artificial. The theoretical prediction of the probe transmission agrees well with the data and the experimental parameters can be derived reasonably from the model. Such narrow and high-contrast spectral profile can be employed as a high precision bandpass filter, which provides a significant advantage in terms of stability and tunability. The central frequency tuning range of the filter is larger than 100 MHz with out-of-band blocking ≥15 dB. This bandpass filter can effectively produce light fields with subnatural linewidth. Nonlinearity associating with the narrow-linewidth and high-contrast EIT profile can be very useful in the applications utilizing the EIT effect.

  7. Mot eit moderne norskfag

    Directory of Open Access Journals (Sweden)

    Magne Rogne

    2008-06-01

    Full Text Available Artikkelen tek for seg tekstomgrepet i norskfaget gjennom læreplananalysar. Først kjem ein faghistorisk gjennomgang med vekt på spørsmålet om norskfaget kan seiast å vere dynamisk i den forstand at det tek opp i seg tekstkulturelle endringar i samfunnet, særleg knytt til medie- og kommunikasjonsutviklinga. Denne gjennomgangen endar opp i ei drøfting av om dagens norskfag kan seiast å ha eit føremålstenleg tekstomgrep i høve til den funksjonen faget skal ha i dagens skule, med eit særleg fokus på spenninga mellom danning og nytte. Artikkelen konkluderer med at norskfaget har endra seg i tråd med samfunnsutviklinga når det gjeld kva type tekstar det er viktig å arbeide med, men òg at dei svake krava til det å meistre tekstproduksjon i dagens plan ikkje er i samsvar med overordna målsetjingar for faget.

  8. Toward morphological thoracic EIT: major signal sources correspond to respective organ locations in CT.

    Science.gov (United States)

    Ferrario, Damien; Grychtol, Bartłomiej; Adler, Andy; Solà, Josep; Böhm, Stephan H; Bodenstein, Marc

    2012-11-01

    Lung and cardiovascular monitoring applications of electrical impedance tomography (EIT) require localization of relevant functional structures or organs of interest within the reconstructed images. We describe an algorithm for automatic detection of heart and lung regions in a time series of EIT images. Using EIT reconstruction based on anatomical models, candidate regions are identified in the frequency domain and image-based classification techniques applied. The algorithm was validated on a set of simultaneously recorded EIT and CT data in pigs. In all cases, identified regions in EIT images corresponded to those manually segmented in the matched CT image. Results demonstrate the ability of EIT technology to reconstruct relevant impedance changes at their anatomical locations, provided that information about the thoracic boundary shape (and electrode positions) are used for reconstruction.

  9. The study on a development and characteristics of EIT system

    International Nuclear Information System (INIS)

    Hyun, J. K.; Lee, H. J.; Lee, Y. J.; Kim, S.; Lee, B. A.; Ko, S. T.; Han, C. K.

    2000-01-01

    EIT(Electrical Impedance Tomography) system is one of instruments to show the inner construction of two phase flow by electrical signal. In this study, we developed a circuit of EIT system, perform current signal generation and voltage measurement, and examined the characteristics. We measured voltages when resistance isn't in the phantom. And then, we compared with the result of forward problem. And found the characteristics when the resistance is in the phantom and a position of the resistance changes in the phantom. Through that, we verified that this EIT system be able to used reconstruct the inner construction of two-phase flow

  10. Reducing computational costs in large scale 3D EIT by using a sparse Jacobian matrix with block-wise CGLS reconstruction

    International Nuclear Information System (INIS)

    Yang, C L; Wei, H Y; Soleimani, M; Adler, A

    2013-01-01

    Electrical impedance tomography (EIT) is a fast and cost-effective technique to provide a tomographic conductivity image of a subject from boundary current–voltage data. This paper proposes a time and memory efficient method for solving a large scale 3D EIT inverse problem using a parallel conjugate gradient (CG) algorithm. The 3D EIT system with a large number of measurement data can produce a large size of Jacobian matrix; this could cause difficulties in computer storage and the inversion process. One of challenges in 3D EIT is to decrease the reconstruction time and memory usage, at the same time retaining the image quality. Firstly, a sparse matrix reduction technique is proposed using thresholding to set very small values of the Jacobian matrix to zero. By adjusting the Jacobian matrix into a sparse format, the element with zeros would be eliminated, which results in a saving of memory requirement. Secondly, a block-wise CG method for parallel reconstruction has been developed. The proposed method has been tested using simulated data as well as experimental test samples. Sparse Jacobian with a block-wise CG enables the large scale EIT problem to be solved efficiently. Image quality measures are presented to quantify the effect of sparse matrix reduction in reconstruction results. (paper)

  11. Reducing computational costs in large scale 3D EIT by using a sparse Jacobian matrix with block-wise CGLS reconstruction.

    Science.gov (United States)

    Yang, C L; Wei, H Y; Adler, A; Soleimani, M

    2013-06-01

    Electrical impedance tomography (EIT) is a fast and cost-effective technique to provide a tomographic conductivity image of a subject from boundary current-voltage data. This paper proposes a time and memory efficient method for solving a large scale 3D EIT inverse problem using a parallel conjugate gradient (CG) algorithm. The 3D EIT system with a large number of measurement data can produce a large size of Jacobian matrix; this could cause difficulties in computer storage and the inversion process. One of challenges in 3D EIT is to decrease the reconstruction time and memory usage, at the same time retaining the image quality. Firstly, a sparse matrix reduction technique is proposed using thresholding to set very small values of the Jacobian matrix to zero. By adjusting the Jacobian matrix into a sparse format, the element with zeros would be eliminated, which results in a saving of memory requirement. Secondly, a block-wise CG method for parallel reconstruction has been developed. The proposed method has been tested using simulated data as well as experimental test samples. Sparse Jacobian with a block-wise CG enables the large scale EIT problem to be solved efficiently. Image quality measures are presented to quantify the effect of sparse matrix reduction in reconstruction results.

  12. Comparative analysis of time efficiency and spatial resolution between different EIT reconstruction algorithms

    International Nuclear Information System (INIS)

    Kacarska, Marija; Loskovska, Suzana

    2002-01-01

    In this paper comparative analysis between different EIT algorithms is presented. Analysis is made for spatial and temporal resolution of obtained images by several different algorithms. Discussions consider spatial resolution dependent on data acquisition method, too. Obtained results show that conventional applied-current EIT is more powerful compared to induced-current EIT. (Author)

  13. A Catalog of Coronal "EIT Wave" Transients

    Science.gov (United States)

    Thompson, B. J.; Myers, D. C.

    2009-01-01

    Solar and Heliospheric Observatory (SOHO) Extreme ultraviolet Imaging Telescope (EIT) data have been visually searched for coronal "EIT wave" transients over the period beginning from 1997 March 24 and extending through 1998 June 24. The dates covered start at the beginning of regular high-cadence (more than one image every 20 minutes) observations, ending at the four-month interruption of SOHO observations in mid-1998. One hundred and seventy six events are included in this catalog. The observations range from "candidate" events, which were either weak or had insufficient data coverage, to events which were well defined and were clearly distinguishable in the data. Included in the catalog are times of the EIT images in which the events are observed, diagrams indicating the observed locations of the wave fronts and associated active regions, and the speeds of the wave fronts. The measured speeds of the wave fronts varied from less than 50 to over 700 km s(exp -1) with "typical" speeds of 200-400 km s(exp -1).

  14. Two narrow bandwidth photons interfering in an electromagnetically induced transparency (EIT) system

    International Nuclear Information System (INIS)

    Wang Fuyuan; Shi Baosen; Lu Xiaosong; Guo Guangcan

    2008-01-01

    In this paper, we have analysed in detail the quantum interference of the degenerate narrowband two-photon state by using a Mach–Zehnder interferometer, in which an electromagnetically induced transparency (EIT) medium is placed in one of two interfering beams. Our results clearly show that it is possible to coherently keep the quantum state at a single photon level in the EIT process, especially when the transparent window of the EIT medium is much larger than the bandwidth of the single photon. This shows that the EIT medium is possibly a kind of memory or repeater for the narrowband photons in the areas of quantum communication and quantum computer. This kind of experiment is feasible within the current technology

  15. Tracking boundary movement and exterior shape modelling in lung EIT imaging

    International Nuclear Information System (INIS)

    Biguri, A; Soleimani, M; Grychtol, B; Adler, A

    2015-01-01

    Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comparison of these approaches is available. This paper analyses boundary model mismatch and electrode movement in lung EIT. The aim is to evaluate the extent to which various algorithms tolerate movement, and to determine if a patient specific model is required for EIT lung imaging. Movement data are simulated from a CT-based model, and image analysis is performed using quantitative figures of merit. The electrode movement is modelled based on expected values of chest movement and an extended Jacobian method is proposed to make use of exterior boundary tracking. Results show that a dynamical boundary tracking is the most robust method against any movement, but is computationally more expensive. Simultaneous electrode movement and conductivity reconstruction algorithms show increased robustness compared to only conductivity reconstruction. The results of this comparative study can help develop a better understanding of the impact of shape model mismatch and electrode movement in lung EIT. (paper)

  16. Tracking boundary movement and exterior shape modelling in lung EIT imaging.

    Science.gov (United States)

    Biguri, A; Grychtol, B; Adler, A; Soleimani, M

    2015-06-01

    Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comparison of these approaches is available. This paper analyses boundary model mismatch and electrode movement in lung EIT. The aim is to evaluate the extent to which various algorithms tolerate movement, and to determine if a patient specific model is required for EIT lung imaging. Movement data are simulated from a CT-based model, and image analysis is performed using quantitative figures of merit. The electrode movement is modelled based on expected values of chest movement and an extended Jacobian method is proposed to make use of exterior boundary tracking. Results show that a dynamical boundary tracking is the most robust method against any movement, but is computationally more expensive. Simultaneous electrode movement and conductivity reconstruction algorithms show increased robustness compared to only conductivity reconstruction. The results of this comparative study can help develop a better understanding of the impact of shape model mismatch and electrode movement in lung EIT.

  17. Feasibility of using 'lung density' values estimated from EIT images for clinical diagnosis of lung abnormalities in mechanically ventilated ICU patients.

    Science.gov (United States)

    Nebuya, Satoru; Koike, Tomotaka; Imai, Hiroshi; Iwashita, Yoshiaki; Brown, Brian H; Soma, Kazui

    2015-06-01

    This paper reports on the results of a study which compares lung density values obtained from electrical impedance tomography (EIT), clinical diagnosis and CT values (HU) within a region of interest in the lung. The purpose was to assess the clinical use of lung density estimation using EIT data. In 11 patients supported by a mechanical ventilator, the consistency of regional lung density measurements as estimated by EIT was validated to assess the feasibility of its use in intensive care medicine. There were significant differences in regional lung densities recorded in the supine position between normal lungs and diseased lungs associated with pneumonia, atelectasis and pleural effusion (normal; 240 ± 71.7 kg m(-3), pneumonia; 306 ± 38.6 kg m(-3), atelectasis; 497 ± 130 kg m(-3), pleural effusion; 467 ± 113 kg m(-3): Steel-Dwass test, p EIT images. The results of CT and EIT images from five patients in an intensive care unit showed a correlation coefficient of 0.66 ± 0.13 between the CT values (HU) and the lung density values (kg m(-3)) obtained from EIT. These results indicate that it may be possible to obtain a quantitative value for regional lung density using EIT.

  18. Does thorax EIT image analysis depend on the image reconstruction method?

    Science.gov (United States)

    Zhao, Zhanqi; Frerichs, Inéz; Pulletz, Sven; Müller-Lisse, Ullrich; Möller, Knut

    2013-04-01

    Different methods were proposed to analyze the resulting images of electrical impedance tomography (EIT) measurements during ventilation. The aim of our study was to examine if the analysis methods based on back-projection deliver the same results when applied on images based on other reconstruction algorithms. Seven mechanically ventilated patients with ARDS were examined by EIT. The thorax contours were determined from the routine CT images. EIT raw data was reconstructed offline with (1) filtered back-projection with circular forward model (BPC); (2) GREIT reconstruction method with circular forward model (GREITC) and (3) GREIT with individual thorax geometry (GREITT). Three parameters were calculated on the resulting images: linearity, global ventilation distribution and regional ventilation distribution. The results of linearity test are 5.03±2.45, 4.66±2.25 and 5.32±2.30 for BPC, GREITC and GREITT, respectively (median ±interquartile range). The differences among the three methods are not significant (p = 0.93, Kruskal-Wallis test). The proportions of ventilation in the right lung are 0.58±0.17, 0.59±0.20 and 0.59±0.25 for BPC, GREITC and GREITT, respectively (p = 0.98). The differences of the GI index based on different reconstruction methods (0.53±0.16, 0.51±0.25 and 0.54±0.16 for BPC, GREITC and GREITT, respectively) are also not significant (p = 0.93). We conclude that the parameters developed for images generated with GREITT are comparable with filtered back-projection and GREITC.

  19. Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT.

    Science.gov (United States)

    Hahn, G; Just, A; Dudykevych, T; Frerichs, I; Hinz, J; Quintel, M; Hellige, G

    2006-05-01

    The increasing use of EIT in clinical research on severely ill lung patients requires a clarification of the influence of pathologic impedance distributions on the validity of the resulting tomograms. Significant accumulation of low-conducting air (e.g. pneumothorax or emphysema) or well-conducting liquid (e.g. haematothorax or atelectases) may conflict with treating the imaging problem as purely linear. First, we investigated the influence of stepwise inflation and deflation by up to 300 ml of air and 300 ml of Ringer solution into the pleural space of five pigs on the resulting tomograms during ventilation at constant tidal volume. Series of EIT images representing relative impedance changes were generated on the basis of a modified Sheffield back projection algorithm and ventilation distribution was displayed as functional (f-EIT) tomograms. In addition, a modified simultaneous iterative reconstruction technique (SIRT) was applied to quantify the resistivity distribution on an absolute level scaled in Omega m (a-EIT). Second, we applied these two EIT techniques on four intensive care patients with inhomogeneous air and fluid distribution and compared the EIT results to computed tomography (CT) and to a reference set of intrathoracic resistivity data of 20 healthy volunteers calculated by SIRT. The results of the animal model show that f-EIT based on back projection is not disturbed by the artificial pneumo- or haematothorax. Application of SIRT allows reliable discrimination and detection of the location and amplitude of pneumo- or haematothorax. These results were supported by the good agreement between the electrical impedance tomograms and CT scans on patients and by the significant differences of regional resistivity data between patients and healthy volunteers.

  20. An instrumental electrode model for solving EIT forward problems.

    Science.gov (United States)

    Zhang, Weida; Li, David

    2014-10-01

    An instrumental electrode model (IEM) capable of describing the performance of electrical impedance tomography (EIT) systems in the MHz frequency range has been proposed. Compared with the commonly used Complete Electrode Model (CEM), which assumes ideal front-end interfaces, the proposed model considers the effects of non-ideal components in the front-end circuits. This introduces an extra boundary condition in the forward model and offers a more accurate modelling for EIT systems. We have demonstrated its performance using simple geometry structures and compared the results with the CEM and full Maxwell methods. The IEM can provide a significantly more accurate approximation than the CEM in the MHz frequency range, where the full Maxwell methods are favoured over the quasi-static approximation. The improved electrode model will facilitate the future characterization and front-end design of real-world EIT systems.

  1. Comparison of distribution of lung aeration measured with EIT and CT in spontaneously breathing, awake patients1.

    Science.gov (United States)

    Radke, Oliver C; Schneider, Thomas; Braune, Anja; Pirracchio, Romain; Fischer, Felix; Koch, Thea

    2016-09-28

    Both Electrical Impedance Tomography (EIT) and Computed Tomography (CT) allow the estimation of the lung area. We compared two algorithms for the detection of the lung area per quadrant from the EIT images with the lung areas derived from the CT images. 39 outpatients who were scheduled for an elective CT scan of the thorax were included in the study. For each patient we recorded EIT images immediately before the CT scan. The lung area per quadrant was estimated from both CT and EIT data using two different algorithms for the EIT data. Data showed considerable variation during spontaneous breathing of the patients. Overall correlation between EIT and CT was poor (0.58-0.77), the correlation between the two EIT algorithms was better (0.90-0.92). Bland-Altmann analysis revealed absence of bias, but wide limits of agreement. Lung area estimation from CT and EIT differs significantly, most probably because of the fundamental difference in image generation.

  2. The Preflight Photometric Calibration of the Extreme-Ultraviolet Imaging Telescope EIT

    Science.gov (United States)

    Dere, K. P.; Moses, J. D.; Delaboudiniere, J. -P.; Brunaud, J.; Carabetian, C.; Hochedez, J. -F.; Song, X. Y.; Catura, R. C.; Clette, F.; Defise, J. -M.

    2000-01-01

    This paper presents the preflight photometric calibration of the Extreme-ultraviolet Imaging Telescope (EIT) aboard the Solar and Heliospheric Observatory (SOHO). The EIT consists of a Ritchey-Chretien telescope with multilayer coatings applied to four quadrants of the primary and secondary mirrors, several filters and a backside-thinned CCD detector. The quadrants of the EIT optics were used to observe the Sun in 4 wavelength bands that peak near 171, 195, 284, and 304 . Before the launch of SOHO, the EIT mirror reflectivities, the filter transmissivities and the CCD quantum efficiency were measured and these values are described here. The instrumental throughput in terms of an effective area is presented for each of the various mirror quadrant and filter wheel combinations. The response to a coronal plasma as a function of temperature is also determined and the expected count rates are compared to the count rates observed in a coronal hole, the quiet Sun and an active region.

  3. Citral a fragrance allergen and irritant

    DEFF Research Database (Denmark)

    Heydorn, S; Menné, T; Andersen, Klaus Ejner

    2003-01-01

    Citral is a well known contact allergen and a contact irritant. Routine patch testing in the past may have been restricted because of possible irritant (IR) patch test responses. 586 consecutive patients, with hand eczema, were patch tested with a selection of fragrances including citral 2% petro...

  4. Dark and bright-state polaritons in triple- Λ EIT system

    Science.gov (United States)

    Selvan, Karthick

    2018-04-01

    Properties of polaritons in triple-Λ EIT system are investigated using Sawada-Brout-Chong method. The role of dark and bright-state polaritons in the dynamics of the system is studied in detail by including the decay of excited atomic levels. Time evolution of entanglement of single and three-photon EIT modes within the system is investigated to explain this study.

  5. Transient behaviour of EIT and EIA in an optical-radio two-photon coupling configuration

    Science.gov (United States)

    Li, Xiaoli; Yang, Zicai; Shang, Yaxuan

    2012-11-01

    Both electromagnetically induced absorption (EIA) and transparency (EIT) can be obtained in a modified quasi-lambda four level system consisting of an optical-radio two-photon coupling field and a probing field. A physical account of EIA and EIT is given in terms of a transient state picture in this paper. It can be seen that the optical coupling field in this quasi-lambda four level system has a crucial effect on the forming of EIA and EIT. An EIA is observed under a resonant optical coupling and it evolves into an EIT when there is a detuning.

  6. Development of a EIT Measurement System for Image Reconstruction of Two-Phase Flow

    International Nuclear Information System (INIS)

    Hyun, Jong Kwan

    2000-02-01

    In the thermal-hydraulic system of a nuclear power plant as well as in many engineering areas, it is common to encounter the two-phase flow phenomenon. It is essential to understand the mechanism of the two-phase flow for the analysis and design of the relevant systems. To obtain the detail information on air bubbles moving in the two-phase flow many various experiments have been attempted. One of them is the EIT (Electrical Impedance Tomography) method, which is getting popular in recent days. The EIT is less expensive than other methods because the system is relatively simple and easy to construct compared to other methods. Nowadays it becomes one of the reliable and efficient methods for estimating the inner structure of the given object and has a wide spectrum of applications in various fields. Especially, even though the spatial resolution of EIT is inferior to those of X-ray and MRI, its temporal resolution is excellent. And its small size and easiness to operate provides itself with the portability. For these reasons, the EIT is properly used in the medical field as an complementary equipment and its use will be expanded in the future. The EIT technology in the area of nuclear energy is suitable for studying the two-phase flow which is necessary for designing the thermal hydraulic system because it can reduce the uncertainty of information. The EIT is also so fast to get the result data during the experiment that it is possible to apply it to the thermal hydraulic system in which the physical process is usually fast. Although the EIT is apply to the complicated structure of rod bundle, its basic principles are the same as of the simple geometrical structure. The adaptation of EIT to the two-phase flow of complicated geometrical structure gives the superior results to those of other methods and it is possible to use it in the reactor thermal hydraulic system as a monitoring equipment. However, even the application fields of the EIT are very wide and its

  7. Influences of lung parenchyma density and thoracic fluid on ventilatory EIT measurements

    NARCIS (Netherlands)

    Kunst, P. W.; Vonk Noordegraaf, A.; Straver, B.; Aarts, R. A.; Tesselaar, C. D.; Postmus, P. E.; de Vries, P. M.

    1998-01-01

    Ventilatory impedance changes can be measured by electrical impedance tomography (EIT). Several studies have pointed out that the ventilatory-induced impedance change measured over the lungs shows a linear relationship with tidal volume. However, EIT measures the ventilatory impedance changes

  8. Detection of admittivity anomaly on high-contrast heterogeneous backgrounds using frequency difference EIT.

    Science.gov (United States)

    Jang, J; Seo, J K

    2015-06-01

    This paper describes a multiple background subtraction method in frequency difference electrical impedance tomography (fdEIT) to detect an admittivity anomaly from a high-contrast background conductivity distribution. The proposed method expands the use of the conventional weighted frequency difference EIT method, which has been used limitedly to detect admittivity anomalies in a roughly homogeneous background. The proposed method can be viewed as multiple weighted difference imaging in fdEIT. Although the spatial resolutions of the output images by fdEIT are very low due to the inherent ill-posedness, numerical simulations and phantom experiments of the proposed method demonstrate its feasibility to detect anomalies. It has potential application in stroke detection in a head model, which is highly heterogeneous due to the skull.

  9. Multi-peak electromagnetically induced transparency (EIT)-like transmission from bull's-eye-shaped metamaterial.

    Science.gov (United States)

    Kim, Jaeyoun; Soref, Richard; Buchwald, Walter R

    2010-08-16

    We investigate the electromagnetic response of the concentric multi-ring, or the bull's eye, structure as an extension of the dual-ring metamaterial which exhibits electromagnetically-induced transparency (EIT)-like transmission characteristics. Our results show that adding inner rings produces additional EIT-like peaks, and widens the metamaterial's spectral range of operation. Analyses of the dispersion characteristics and induced current distribution further confirmed the peak's EIT-like nature. Impacts of structural and dielectric parameters are also investigated.

  10. Profile of irritant patch testing with detergents: sodium lauryl sulfate, sodium laureth sulfate and alkyl polyglucoside.

    Science.gov (United States)

    Löffler, H; Happle, R

    2003-01-01

    The cutaneous reaction to detergents follows distinct kinetic rules: the duration of application and the irritant concentration are of major importance. The aim of this study was to evaluate the differences in kinetics of skin reaction between the standard irritant sodium lauryl sulfate (SLS), and 2 modern detergents: sodium laureth sulfate (SLES) and alkyl polyglucoside (APG). We performed patch testing with SLS and SLES (or APG) at different concentrations (0.125, 0.25, 0.5, 1.0 and 2.0%) and with different exposure times (6, 12 and 24 h). Evaluation was conducted by measurement of transepidermal water loss (TEWL) and laser Doppler flowmetry (LD) 24 h, 7 and 10 days after patch removal. We found a pronounced reaction to SLS, and a far milder one to SLES. Even at the highest concentration the skin reaction to APG was hard to detect. During the regeneration period (day 3-10) SLS showed even at day 10 an increased TEWL at all concentrations tested. The irritation due to SLES was convincingly detectable only up to day 7, whereas the APG-tested skin areas showed no significant reaction even at day 3. These results demonstrate the improvement in reduction of skin irritation achieved by development of novel detergents.

  11. Coupling of EIT with computational lung modeling for predicting patient-specific ventilatory responses.

    Science.gov (United States)

    Roth, Christian J; Becher, Tobias; Frerichs, Inéz; Weiler, Norbert; Wall, Wolfgang A

    2017-04-01

    Providing optimal personalized mechanical ventilation for patients with acute or chronic respiratory failure is still a challenge within a clinical setting for each case anew. In this article, we integrate electrical impedance tomography (EIT) monitoring into a powerful patient-specific computational lung model to create an approach for personalizing protective ventilatory treatment. The underlying computational lung model is based on a single computed tomography scan and able to predict global airflow quantities, as well as local tissue aeration and strains for any ventilation maneuver. For validation, a novel "virtual EIT" module is added to our computational lung model, allowing to simulate EIT images based on the patient's thorax geometry and the results of our numerically predicted tissue aeration. Clinically measured EIT images are not used to calibrate the computational model. Thus they provide an independent method to validate the computational predictions at high temporal resolution. The performance of this coupling approach has been tested in an example patient with acute respiratory distress syndrome. The method shows good agreement between computationally predicted and clinically measured airflow data and EIT images. These results imply that the proposed framework can be used for numerical prediction of patient-specific responses to certain therapeutic measures before applying them to an actual patient. In the long run, definition of patient-specific optimal ventilation protocols might be assisted by computational modeling. NEW & NOTEWORTHY In this work, we present a patient-specific computational lung model that is able to predict global and local ventilatory quantities for a given patient and any selected ventilation protocol. For the first time, such a predictive lung model is equipped with a virtual electrical impedance tomography module allowing real-time validation of the computed results with the patient measurements. First promising results

  12. A method to achieve large tunable delays based on EIT in an inhomogeneously broadened quantum dot medium

    DEFF Research Database (Denmark)

    Hansen, Per Lunnemann; Mørk, Jesper

    2009-01-01

    We propose a scheme for reducing the impact of inhomogeneous broadening on quantum dot based EIT for slow light. Field propagation calculations show superior performance in delay compared to traditionally investigated EIT schemes.......We propose a scheme for reducing the impact of inhomogeneous broadening on quantum dot based EIT for slow light. Field propagation calculations show superior performance in delay compared to traditionally investigated EIT schemes....

  13. Mutual information as a measure of image quality for 3D dynamic lung imaging with EIT.

    Science.gov (United States)

    Crabb, M G; Davidson, J L; Little, R; Wright, P; Morgan, A R; Miller, C A; Naish, J H; Parker, G J M; Kikinis, R; McCann, H; Lionheart, W R B

    2014-05-01

    We report on a pilot study of dynamic lung electrical impedance tomography (EIT) at the University of Manchester. Low-noise EIT data at 100 frames per second were obtained from healthy male subjects during controlled breathing, followed by magnetic resonance imaging (MRI) subsequently used for spatial validation of the EIT reconstruction. The torso surface in the MR image and electrode positions obtained using MRI fiducial markers informed the construction of a 3D finite element model extruded along the caudal-distal axis of the subject. Small changes in the boundary that occur during respiration were accounted for by incorporating the sensitivity with respect to boundary shape into a robust temporal difference reconstruction algorithm. EIT and MRI images were co-registered using the open source medical imaging software, 3D Slicer. A quantitative comparison of quality of different EIT reconstructions was achieved through calculation of the mutual information with a lung-segmented MR image. EIT reconstructions using a linear shape correction algorithm reduced boundary image artefacts, yielding better contrast of the lungs, and had 10% greater mutual information compared with a standard linear EIT reconstruction.

  14. Robust linearized image reconstruction for multifrequency EIT of the breast.

    Science.gov (United States)

    Boverman, Gregory; Kao, Tzu-Jen; Kulkarni, Rujuta; Kim, Bong Seok; Isaacson, David; Saulnier, Gary J; Newell, Jonathan C

    2008-10-01

    Electrical impedance tomography (EIT) is a developing imaging modality that is beginning to show promise for detecting and characterizing tumors in the breast. At Rensselaer Polytechnic Institute, we have developed a combined EIT-tomosynthesis system that allows for the coregistered and simultaneous analysis of the breast using EIT and X-ray imaging. A significant challenge in EIT is the design of computationally efficient image reconstruction algorithms which are robust to various forms of model mismatch. Specifically, we have implemented a scaling procedure that is robust to the presence of a thin highly-resistive layer of skin at the boundary of the breast and we have developed an algorithm to detect and exclude from the image reconstruction electrodes that are in poor contact with the breast. In our initial clinical studies, it has been difficult to ensure that all electrodes make adequate contact with the breast, and thus procedures for the use of data sets containing poorly contacting electrodes are particularly important. We also present a novel, efficient method to compute the Jacobian matrix for our linearized image reconstruction algorithm by reducing the computation of the sensitivity for each voxel to a quadratic form. Initial clinical results are presented, showing the potential of our algorithms to detect and localize breast tumors.

  15. Citral a fragrance allergen and irritant.

    Science.gov (United States)

    Heydorn, S; Menné, T; Andersen, K E; Bruze, M; Svedman, C; White, I R; Basketter, D A

    2003-07-01

    Citral is a well known contact allergen and a contact irritant. Routine patch testing in the past may have been restricted because of possible irritant (IR) patch test responses. 586 consecutive patients, with hand eczema, were patch tested with a selection of fragrances including citral 2% petrolatum and the European standard series. 28 of the patients showed a positive patch test reaction (+ to +++) to citral and 82 at least 1 IR patch test reaction and no positive patch test reaction to citral. A statistically significant association between a positive patch test reaction to citral and positive patch test reactions to other fragrances compared with IR reactions (n = 82) was established. The difference regarding fragrance history found between those with IR and positive reactions to citral was not significant. Citral could be an allergen and/or irritant, worthy of further more extensive studies.

  16. Broadband EIT borehole measurements with high phase accuracy using numerical corrections of electromagnetic coupling effects

    International Nuclear Information System (INIS)

    Zhao, Y; Zimmermann, E; Wolters, B; Van Waasen, S; Huisman, J A; Treichel, A; Kemna, A

    2013-01-01

    Electrical impedance tomography (EIT) is gaining importance in the field of geophysics and there is increasing interest for accurate borehole EIT measurements in a broad frequency range (mHz to kHz) in order to study subsurface properties. To characterize weakly polarizable soils and sediments with EIT, high phase accuracy is required. Typically, long electrode cables are used for borehole measurements. However, this may lead to undesired electromagnetic coupling effects associated with the inductive coupling between the double wire pairs for current injection and potential measurement and the capacitive coupling between the electrically conductive shield of the cable and the electrically conductive environment surrounding the electrode cables. Depending on the electrical properties of the subsurface and the measured transfer impedances, both coupling effects can cause large phase errors that have typically limited the frequency bandwidth of field EIT measurements to the mHz to Hz range. The aim of this paper is to develop numerical corrections for these phase errors. To this end, the inductive coupling effect was modeled using electronic circuit models, and the capacitive coupling effect was modeled by integrating discrete capacitances in the electrical forward model describing the EIT measurement process. The correction methods were successfully verified with measurements under controlled conditions in a water-filled rain barrel, where a high phase accuracy of 0.8 mrad in the frequency range up to 10 kHz was achieved. The corrections were also applied to field EIT measurements made using a 25 m long EIT borehole chain with eight electrodes and an electrode separation of 1 m. The results of a 1D inversion of these measurements showed that the correction methods increased the measurement accuracy considerably. It was concluded that the proposed correction methods enlarge the bandwidth of the field EIT measurement system, and that accurate EIT measurements can now

  17. A Quantitative Evaluation of Drive Pattern Selection for Optimizing EIT-Based Stretchable Sensors

    Directory of Open Access Journals (Sweden)

    Stefania Russo

    2017-08-01

    Full Text Available Electrical Impedance Tomography (EIT is a medical imaging technique that has been recently used to realize stretchable pressure sensors. In this method, voltage measurements are taken at electrodes placed at the boundary of the sensor and are used to reconstruct an image of the applied touch pressure points. The drawback with EIT-based sensors, however, is their low spatial resolution due to the ill-posed nature of the EIT reconstruction. In this paper, we show our performance evaluation of different EIT drive patterns, specifically strategies for electrode selection when performing current injection and voltage measurements. We compare voltage data with Signal-to-Noise Ratio (SNR and Boundary Voltage Changes (BVC, and study image quality with Size Error (SE, Position Error (PE and Ringing (RNG parameters, in the case of one-point and two-point simultaneous contact locations. The study shows that, in order to improve the performance of EIT based sensors, the electrode selection strategies should dynamically change correspondingly to the location of the input stimuli. In fact, the selection of one drive pattern over another can improve the target size detection and position accuracy up to 4.7% and 18%, respectively.

  18. A Quantitative Evaluation of Drive Pattern Selection for Optimizing EIT-Based Stretchable Sensors.

    Science.gov (United States)

    Russo, Stefania; Nefti-Meziani, Samia; Carbonaro, Nicola; Tognetti, Alessandro

    2017-08-31

    Electrical Impedance Tomography (EIT) is a medical imaging technique that has been recently used to realize stretchable pressure sensors. In this method, voltage measurements are taken at electrodes placed at the boundary of the sensor and are used to reconstruct an image of the applied touch pressure points. The drawback with EIT-based sensors, however, is their low spatial resolution due to the ill-posed nature of the EIT reconstruction. In this paper, we show our performance evaluation of different EIT drive patterns, specifically strategies for electrode selection when performing current injection and voltage measurements. We compare voltage data with Signal-to-Noise Ratio (SNR) and Boundary Voltage Changes (BVC), and study image quality with Size Error (SE), Position Error (PE) and Ringing (RNG) parameters, in the case of one-point and two-point simultaneous contact locations. The study shows that, in order to improve the performance of EIT based sensors, the electrode selection strategies should dynamically change correspondingly to the location of the input stimuli. In fact, the selection of one drive pattern over another can improve the target size detection and position accuracy up to 4.7% and 18%, respectively.

  19. Simultaneous application of two independent EIT devices for real-time multi-plane imaging.

    Science.gov (United States)

    Schullcke, B; Krueger-Ziolek, S; Gong, B; Mueller-Lisse, U; Moeller, K

    2016-09-01

    Diagnosis and treatment of many lung diseases like cystic fibrosis (CF) or chronic obstructive pulmonary disease (COPD) could benefit from 3D ventilation information. Applying two EIT systems concurrently is a simple approach without specialized hardware that allows monitoring of regional changes of ventilation distribution inside the thorax at different planes with the high temporal resolution much valued in common single plane EIT. Effects of two simultaneously operated EIT devices on one subject were investigated to monitor rapid processes inside the thorax with a multi-plane approach. Results obtained by simulations with a virtual phantom and measurements with a phantom tank reveal that the distance of electrode planes has an important influence on the signal quality. Band-pass filters adapted according to the distance of the planes, can be used to reduce the crosstalk of the concurrent EIT systems. Besides simulations and phantom tank experiments measurements were also taken from a lung healthy volunteer to demonstrate the operation under realistic conditions. Reconstructed images indicate that it is possible to simultaneously visualize regional ventilation at different planes if settings of the EIT devices are chosen appropriately.

  20. A tiered approach to the use of alternatives to animal testing for the safety assessment of cosmetics: skin irritation.

    Science.gov (United States)

    Macfarlane, Martin; Jones, Penny; Goebel, Carsten; Dufour, Eric; Rowland, Joanna; Araki, Daisuke; Costabel-Farkas, Margit; Hewitt, Nicola J; Hibatallah, Jalila; Kirst, Annette; McNamee, Pauline; Schellauf, Florian; Scheel, Julia

    2009-07-01

    Evaluation of the skin irritancy and corrosivity potential of an ingredient is a necessity in the safety assessment of cosmetic ingredients. To date, there are two formally validated alternatives to the rabbit Draize test for skin corrosivity in place, namely the rat skin transcutaneous electrical resistance (TER) assay and the Human Skin Model Test using EpiSkin, EpiDerm and SkinEthic reconstructed human epidermal equivalents. For skin irritation, EpiSkin, EpiDerm and SkinEthic are validated as stand-alone test replacements for the rabbit Draize test. Data from these tests are rarely considered in isolation and are evaluated in combination with other factors to establish the overall irritating or corrosive potential of an ingredient. In light of the deadlines established in the Cosmetics Directive for cessation of animal testing for cosmetic ingredients, a COLIPA scientific meeting was held in Brussels on 30th January, 2008 to review the use of alternative approaches and to set up a decision tree approach for their integration into tiered testing strategies for hazard and safety assessment of cosmetic ingredients and their use in products. In conclusion, the safety assessments for skin irritation/corrosion of new chemicals for use in cosmetics can be confidently accomplished using exclusively alternative methods.

  1. Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT).

    Science.gov (United States)

    Shi, Chang; Boehme, Stefan; Bentley, Alexander H; Hartmann, Erik K; Klein, Klaus U; Bodenstein, Marc; Baumgardner, James E; David, Matthias; Ullrich, Roman; Markstaller, Klaus

    2014-01-01

    Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R(2) = 0.96. Bland-Altman analysis showed a bias of -1.07±24.71 ml and limits of agreement of -49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R(2) values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.

  2. A resistive mesh phantom for assessing the performance of EIT systems.

    Science.gov (United States)

    Gagnon, Hervé; Cousineau, Martin; Adler, Andy; Hartinger, Alzbeta E

    2010-09-01

    Assessing the performance of electrical impedance tomography (EIT) systems usually requires a phantom for validation, calibration, or comparison purposes. This paper describes a resistive mesh phantom to assess the performance of EIT systems while taking into account cabling stray effects similar to in vivo conditions. This phantom is built with 340 precision resistors on a printed circuit board representing a 2-D circular homogeneous medium. It also integrates equivalent electrical models of the Ag/AgCl electrode impedances. The parameters of the electrode models were fitted from impedance curves measured with an impedance analyzer. The technique used to build the phantom is general and applicable to phantoms of arbitrary shape and conductivity distribution. We describe three performance indicators that can be measured with our phantom for every measurement of an EIT data frame: SNR, accuracy, and modeling accuracy. These performance indicators were evaluated on our EIT system under different frame rates and applied current intensities. The performance indicators are dependent on frame rate, operating frequency, applied current intensity, measurement strategy, and intermodulation distortion when performing simultaneous measurements at several frequencies. These parameter values should, therefore, always be specified when reporting performance indicators to better appreciate their significance.

  3. Breath tests and irritable bowel syndrome.

    Science.gov (United States)

    Rana, Satya Vati; Malik, Aastha

    2014-06-28

    Breath tests are non-invasive tests and can detect H₂ and CH₄ gases which are produced by bacterial fermentation of unabsorbed intestinal carbohydrate and are excreted in the breath. These tests are used in the diagnosis of carbohydrate malabsorption, small intestinal bacterial overgrowth, and for measuring the orocecal transit time. Malabsorption of carbohydrates is a key trigger of irritable bowel syndrome (IBS)-type symptoms such as diarrhea and/or constipation, bloating, excess flatulence, headaches and lack of energy. Abdominal bloating is a common nonspecific symptom which can negatively impact quality of life. It may reflect dietary imbalance, such as excess fiber intake, or may be a manifestation of IBS. However, bloating may also represent small intestinal bacterial overgrowth. Patients with persistent symptoms of abdominal bloating and distension despite dietary interventions should be referred for H₂ breath testing to determine the presence or absence of bacterial overgrowth. If bacterial overgrowth is identified, patients are typically treated with antibiotics. Evaluation of IBS generally includes testing of other disorders that cause similar symptoms. Carbohydrate malabsorption (lactose, fructose, sorbitol) can cause abdominal fullness, bloating, nausea, abdominal pain, flatulence, and diarrhea, which are similar to the symptoms of IBS. However, it is unclear if these digestive disorders contribute to or cause the symptoms of IBS. Research studies show that a proper diagnosis and effective dietary intervention significantly reduces the severity and frequency of gastrointestinal symptoms in IBS. Thus, diagnosis of malabsorption of these carbohydrates in IBS using a breath test is very important to guide the clinician in the proper treatment of IBS patients.

  4. Evaluation of the medical devices benchmark materials in the controlled human patch testing and in the RhE in vitro skin irritation protocol.

    NARCIS (Netherlands)

    Kandárová, Helena; Bendova, Hana; Letasiova, Silvia; Coleman, Kelly P; De Jong, Wim H; Jírova, Dagmar

    2018-01-01

    Several irritants were used in the in vitro irritation medical device round robin. The objective of this study was to verify their irritation potential using the human patch test (HPT), an in vitro assay, and in vivo data. The irritants were lactic acid (LA), heptanoic acid (HA), sodium dodecyl

  5. Phase correction of electromagnetic coupling effects in cross-borehole EIT measurements

    International Nuclear Information System (INIS)

    Zhao, Y; Zimmermann, E; Wolters, B; Van Waasen, S; Huisman, J A; Treichel, A; Kemna, A

    2015-01-01

    Borehole EIT measurements in a broad frequency range (mHz to kHz) are used to study subsurface geophysical properties. However, accurate measurements have long been difficult because the required long electric cables introduce undesired inductive and capacitive coupling effects. Recently, it has been shown that such effects can successfully be corrected in the case of single-borehole measurements. The aim of this paper is to extend the previously developed correction procedure for inductive coupling during EIT measurements in a single borehole to cross-borehole EIT measurements with multiple borehole electrode chains. In order to accelerate and simplify the previously developed correction procedure for inductive coupling, a pole–pole matrix of mutual inductances is defined. This consists of the inductances of each individual chain obtained from calibration measurements and the inductances between two chains calculated from the known cable positions using numerical modelling. The new correction procedure is successfully verified with measurements in a water-filled pool under controlled conditions where the errors introduced by capacitive coupling were well-defined and could be estimated by FEM forward modelling. In addition, EIT field measurements demonstrate that the correction methods increase the phase accuracy considerably. Overall, the phase accuracy of cross-hole EIT measurements after correction of inductive and capacitive coupling is improved to better than 1 mrad up to a frequency of 1 kHz, which substantially improves our ability to characterize the frequency-dependent complex electrical resistivity of weakly polarizable soils and sediments in situ. (paper)

  6. Feasibility of imaging epileptic seizure onset with EIT and depth electrodes.

    Science.gov (United States)

    Witkowska-Wrobel, Anna; Aristovich, Kirill; Faulkner, Mayo; Avery, James; Holder, David

    2018-06-01

    Imaging ictal and interictal activity with Electrical Impedance Tomography (EIT) using intracranial electrode mats has been demonstrated in animal models of epilepsy. In human epilepsy subjects undergoing presurgical evaluation, depth electrodes are often preferred. The purpose of this work was to evaluate the feasibility of using EIT to localise epileptogenic areas with intracranial electrodes in humans. The accuracy of localisation of the ictal onset zone was evaluated in computer simulations using 9M element FEM models derived from three subjects. 5 mm radius perturbations imitating a single seizure onset event were placed in several locations forming two groups: under depth electrode coverage and in the contralateral hemisphere. Simulations were made for impedance changes of 1% expected for neuronal depolarisation over milliseconds and 10% for cell swelling over seconds. Reconstructions were compared with EEG source modelling for a radially orientated dipole with respect to the closest EEG recording contact. The best accuracy of EIT was obtained using all depth and 32 scalp electrodes, greater than the equivalent accuracy with EEG inverse source modelling. The localisation error was 5.2 ± 1.8, 4.3 ± 0 and 46.2 ± 25.8 mm for perturbations within the volume enclosed by depth electrodes and 29.6 ± 38.7, 26.1 ± 36.2, 54.0 ± 26.2 mm for those without (EIT 1%, 10% change, EEG source modelling, n = 15 in 3 subjects, p EIT was insensitive to source dipole orientation, all 15 perturbations within the volume enclosed by depth electrodes were localised, whereas the standard clinical method of visual inspection of EEG voltages, only localised 8 out of 15 cases. This suggests that adding EIT to SEEG measurements could be beneficial in localising the onset of seizures. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  7. EIT forward problem parallel simulation environment with anisotropic tissue and realistic electrode models.

    Science.gov (United States)

    De Marco, Tommaso; Ries, Florian; Guermandi, Marco; Guerrieri, Roberto

    2012-05-01

    Electrical impedance tomography (EIT) is an imaging technology based on impedance measurements. To retrieve meaningful insights from these measurements, EIT relies on detailed knowledge of the underlying electrical properties of the body. This is obtained from numerical models of current flows therein. The nonhomogeneous and anisotropic electric properties of human tissues make accurate modeling and simulation very challenging, leading to a tradeoff between physical accuracy and technical feasibility, which at present severely limits the capabilities of EIT. This work presents a complete algorithmic flow for an accurate EIT modeling environment featuring high anatomical fidelity with a spatial resolution equal to that provided by an MRI and a novel realistic complete electrode model implementation. At the same time, we demonstrate that current graphics processing unit (GPU)-based platforms provide enough computational power that a domain discretized with five million voxels can be numerically modeled in about 30 s.

  8. EIT: Solar corona synoptic observations from SOHO with an Extreme-ultraviolet Imaging Telescope

    Science.gov (United States)

    Delaboudiniere, J. P.; Gabriel, A. H.; Artzner, G. E.; Michels, D. J.; Dere, K. P.; Howard, R. A.; Catura, R.; Stern, R.; Lemen, J.; Neupert, W.

    1988-01-01

    The Extreme-ultraviolet Imaging Telescope (EIT) of SOHO (solar and heliospheric observatory) will provide full disk images in emission lines formed at temperatures that map solar structures ranging from the chromospheric network to the hot magnetically confined plasma in the corona. Images in four narrow bandpasses will be obtained using normal incidence multilayered optics deposited on quadrants of a Ritchey-Chretien telescope. The EIT is capable of providing a uniform one arc second resolution over its entire 50 by 50 arc min field of view. Data from the EIT will be extremely valuable for identifying and interpreting the spatial and temperature fine structures of the solar atmosphere. Temporal analysis will provide information on the stability of these structures and identify dynamical processes. EIT images, issued daily, will provide the global corona context for aid in unifying the investigations and in forming the observing plans for SOHO coronal instruments.

  9. Addressing the computational cost of large EIT solutions

    International Nuclear Information System (INIS)

    Boyle, Alistair; Adler, Andy; Borsic, Andrea

    2012-01-01

    Electrical impedance tomography (EIT) is a soft field tomography modality based on the application of electric current to a body and measurement of voltages through electrodes at the boundary. The interior conductivity is reconstructed on a discrete representation of the domain using a finite-element method (FEM) mesh and a parametrization of that domain. The reconstruction requires a sequence of numerically intensive calculations. There is strong interest in reducing the cost of these calculations. An improvement in the compute time for current problems would encourage further exploration of computationally challenging problems such as the incorporation of time series data, wide-spread adoption of three-dimensional simulations and correlation of other modalities such as CT and ultrasound. Multicore processors offer an opportunity to reduce EIT computation times but may require some restructuring of the underlying algorithms to maximize the use of available resources. This work profiles two EIT software packages (EIDORS and NDRM) to experimentally determine where the computational costs arise in EIT as problems scale. Sparse matrix solvers, a key component for the FEM forward problem and sensitivity estimates in the inverse problem, are shown to take a considerable portion of the total compute time in these packages. A sparse matrix solver performance measurement tool, Meagre-Crowd, is developed to interface with a variety of solvers and compare their performance over a range of two- and three-dimensional problems of increasing node density. Results show that distributed sparse matrix solvers that operate on multiple cores are advantageous up to a limit that increases as the node density increases. We recommend a selection procedure to find a solver and hardware arrangement matched to the problem and provide guidance and tools to perform that selection. (paper)

  10. Addressing the computational cost of large EIT solutions.

    Science.gov (United States)

    Boyle, Alistair; Borsic, Andrea; Adler, Andy

    2012-05-01

    Electrical impedance tomography (EIT) is a soft field tomography modality based on the application of electric current to a body and measurement of voltages through electrodes at the boundary. The interior conductivity is reconstructed on a discrete representation of the domain using a finite-element method (FEM) mesh and a parametrization of that domain. The reconstruction requires a sequence of numerically intensive calculations. There is strong interest in reducing the cost of these calculations. An improvement in the compute time for current problems would encourage further exploration of computationally challenging problems such as the incorporation of time series data, wide-spread adoption of three-dimensional simulations and correlation of other modalities such as CT and ultrasound. Multicore processors offer an opportunity to reduce EIT computation times but may require some restructuring of the underlying algorithms to maximize the use of available resources. This work profiles two EIT software packages (EIDORS and NDRM) to experimentally determine where the computational costs arise in EIT as problems scale. Sparse matrix solvers, a key component for the FEM forward problem and sensitivity estimates in the inverse problem, are shown to take a considerable portion of the total compute time in these packages. A sparse matrix solver performance measurement tool, Meagre-Crowd, is developed to interface with a variety of solvers and compare their performance over a range of two- and three-dimensional problems of increasing node density. Results show that distributed sparse matrix solvers that operate on multiple cores are advantageous up to a limit that increases as the node density increases. We recommend a selection procedure to find a solver and hardware arrangement matched to the problem and provide guidance and tools to perform that selection.

  11. Whither lung EIT: Where are we, where do we want to go and what do we need to get there?

    International Nuclear Information System (INIS)

    Adler, Andy; Amato, Marcelo B; Arnold, John H; Wolf, Gerhard K; Bayford, Richard; Bodenstein, Marc; Böhm, Stephan H; Brown, Brian H; Frerichs, Inéz; Weiler, Norbert; Stenqvist, Ola

    2012-01-01

    Breathing moves volumes of electrically insulating air into and out of the lungs, producing conductivity changes which can be seen by electrical impedance tomography (EIT). It has thus been apparent, since the early days of EIT research, that imaging of ventilation could become a key clinical application of EIT. In this paper, we review the current state and future prospects for lung EIT, by a synthesis of the presentations of the authors at the ‘special lung sessions’ of the annual biomedical EIT conferences in 2009–2011. We argue that lung EIT research has arrived at an important transition. It is now clear that valid and reproducible physiological information is available from EIT lung images. We must now ask the question: How can these data be used to help improve patient outcomes? To answer this question, we develop a classification of possible clinical scenarios in which EIT could play an important role, and we identify clinical and experimental research programmes and engineering developments required to turn EIT into a clinically useful tool for lung monitoring. (paper)

  12. Whither lung EIT: where are we, where do we want to go and what do we need to get there?

    Science.gov (United States)

    Adler, Andy; Amato, Marcelo B; Arnold, John H; Bayford, Richard; Bodenstein, Marc; Böhm, Stephan H; Brown, Brian H; Frerichs, Inéz; Stenqvist, Ola; Weiler, Norbert; Wolf, Gerhard K

    2012-05-01

    Breathing moves volumes of electrically insulating air into and out of the lungs, producing conductivity changes which can be seen by electrical impedance tomography (EIT). It has thus been apparent, since the early days of EIT research, that imaging of ventilation could become a key clinical application of EIT. In this paper, we review the current state and future prospects for lung EIT, by a synthesis of the presentations of the authors at the 'special lung sessions' of the annual biomedical EIT conferences in 2009-2011. We argue that lung EIT research has arrived at an important transition. It is now clear that valid and reproducible physiological information is available from EIT lung images. We must now ask the question: How can these data be used to help improve patient outcomes? To answer this question, we develop a classification of possible clinical scenarios in which EIT could play an important role, and we identify clinical and experimental research programmes and engineering developments required to turn EIT into a clinically useful tool for lung monitoring.

  13. What Do High-Resolution EIT Waves Tell Us About CMEs?

    Science.gov (United States)

    Thompson, Barbara

    2010-01-01

    Although many studies have demonstrated that some coronal waves are not generated by corona) mass ejections, we have learned a great deal about the ability of corona) mass ejections to drive large-scale corona) waves, also called "EIT waves." We present new results based on EIT wave amplitude, timing, speed, and direction of propagation, with respect to their correlation with CME-related dimmings, speeds, locations and widths. Furthermore, we demonstrate the ability to correlate different aspects of EIT waves with some of the observed structure of CMEs observed in coronagraph data. Finally, we expand on the discussion of the types of wave modes that can be generated by a corona) mass ejection, and how these observations can serve as a diagnostic of the type of impulse a CME can deliver to the surrounding corona. These diagnostics are obtained by examining the motion of individual field lines, requiring high-resolution observations like those provided by TRACE and SDO/AIA.

  14. Correction of electrode modelling errors in multi-frequency EIT imaging.

    Science.gov (United States)

    Jehl, Markus; Holder, David

    2016-06-01

    The differentiation of haemorrhagic from ischaemic stroke using electrical impedance tomography (EIT) requires measurements at multiple frequencies, since the general lack of healthy measurements on the same patient excludes time-difference imaging methods. It has previously been shown that the inaccurate modelling of electrodes constitutes one of the largest sources of image artefacts in non-linear multi-frequency EIT applications. To address this issue, we augmented the conductivity Jacobian matrix with a Jacobian matrix with respect to electrode movement. Using this new algorithm, simulated ischaemic and haemorrhagic strokes in a realistic head model were reconstructed for varying degrees of electrode position errors. The simultaneous recovery of conductivity spectra and electrode positions removed most artefacts caused by inaccurately modelled electrodes. Reconstructions were stable for electrode position errors of up to 1.5 mm standard deviation along both surface dimensions. We conclude that this method can be used for electrode model correction in multi-frequency EIT.

  15. Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group.

    Science.gov (United States)

    Frerichs, Inéz; Amato, Marcelo B P; van Kaam, Anton H; Tingay, David G; Zhao, Zhanqi; Grychtol, Bartłomiej; Bodenstein, Marc; Gagnon, Hervé; Böhm, Stephan H; Teschner, Eckhard; Stenqvist, Ola; Mauri, Tommaso; Torsani, Vinicius; Camporota, Luigi; Schibler, Andreas; Wolf, Gerhard K; Gommers, Diederik; Leonhardt, Steffen; Adler, Andy

    2017-01-01

    Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Feasibility of using ‘lung density’ values estimated from EIT images for clinical diagnosis of lung abnormalities in mechanically ventilated ICU patients

    International Nuclear Information System (INIS)

    Nebuya, Satoru; Koike, Tomotaka; Imai, Hiroshi; Iwashita, Yoshiaki; Brown, Brian H; Soma, Kazui

    2015-01-01

    This paper reports on the results of a study which compares lung density values obtained from electrical impedance tomography (EIT), clinical diagnosis and CT values (HU) within a region of interest in the lung. The purpose was to assess the clinical use of lung density estimation using EIT data. In 11 patients supported by a mechanical ventilator, the consistency of regional lung density measurements as estimated by EIT was validated to assess the feasibility of its use in intensive care medicine. There were significant differences in regional lung densities recorded in the supine position between normal lungs and diseased lungs associated with pneumonia, atelectasis and pleural effusion (normal; 240 ± 71.7 kg m"−"3, pneumonia; 306 ± 38.6 kg m"−"3, atelectasis; 497 ± 130 kg m"−"3, pleural effusion; 467 ± 113 kg m"−"3: Steel–Dwass test, p < 0.05). In addition, in order to compare lung density with CT image pixels, the image resolution of CT images, which was originally 512 × 512 pixels, was changed to 16 × 16 pixels to match that of the EIT images. The results of CT and EIT images from five patients in an intensive care unit showed a correlation coefficient of 0.66 ± 0.13 between the CT values (HU) and the lung density values (kg m"−"3) obtained from EIT. These results indicate that it may be possible to obtain a quantitative value for regional lung density using EIT. (paper)

  17. Phantom experiments using soft-prior regularization EIT for breast cancer imaging.

    Science.gov (United States)

    Murphy, Ethan K; Mahara, Aditya; Wu, Xiaotian; Halter, Ryan J

    2017-06-01

    A soft-prior regularization (SR) electrical impedance tomography (EIT) technique for breast cancer imaging is described, which shows an ability to accurately reconstruct tumor/inclusion conductivity values within a dense breast model investigated using a cylindrical and a breast-shaped tank. The SR-EIT method relies on knowing the spatial location of a suspicious lesion initially detected from a second imaging modality. Standard approaches (using Laplace smoothing and total variation regularization) without prior structural information are unable to accurately reconstruct or detect the tumors. The soft-prior approach represents a very significant improvement to these standard approaches, and has the potential to improve conventional imaging techniques, such as automated whole breast ultrasound (AWB-US), by providing electrical property information of suspicious lesions to improve AWB-US's ability to discriminate benign from cancerous lesions. Specifically, the best soft-regularization technique found average absolute tumor/inclusion errors of 0.015 S m -1 for the cylindrical test and 0.055 S m -1 and 0.080 S m -1 for the breast-shaped tank for 1.8 cm and 2.5 cm inclusions, respectively. The standard approaches were statistically unable to distinguish the tumor from the mammary gland tissue. An analysis of false tumors (benign suspicious lesions) provides extra insight into the potential and challenges EIT has for providing clinically relevant information. The ability to obtain accurate conductivity values of a suspicious lesion (>1.8 cm) detected from another modality (e.g. AWB-US) could significantly reduce false positives and result in a clinically important technology.

  18. Absolute electrical impedance tomography (aEIT) guided ventilation therapy in critical care patients: simulations and future trends.

    Science.gov (United States)

    Denaï, Mouloud A; Mahfouf, Mahdi; Mohamad-Samuri, Suzani; Panoutsos, George; Brown, Brian H; Mills, Gary H

    2010-05-01

    Thoracic electrical impedance tomography (EIT) is a noninvasive, radiation-free monitoring technique whose aim is to reconstruct a cross-sectional image of the internal spatial distribution of conductivity from electrical measurements made by injecting small alternating currents via an electrode array placed on the surface of the thorax. The purpose of this paper is to discuss the fundamentals of EIT and demonstrate the principles of mechanical ventilation, lung recruitment, and EIT imaging on a comprehensive physiological model, which combines a model of respiratory mechanics, a model of the human lung absolute resistivity as a function of air content, and a 2-D finite-element mesh of the thorax to simulate EIT image reconstruction during mechanical ventilation. The overall model gives a good understanding of respiratory physiology and EIT monitoring techniques in mechanically ventilated patients. The model proposed here was able to reproduce consistent images of ventilation distribution in simulated acutely injured and collapsed lung conditions. A new advisory system architecture integrating a previously developed data-driven physiological model for continuous and noninvasive predictions of blood gas parameters with the regional lung function data/information generated from absolute EIT (aEIT) is proposed for monitoring and ventilator therapy management of critical care patients.

  19. EIT image regularization by a new Multi-Objective Simulated Annealing algorithm.

    Science.gov (United States)

    Castro Martins, Thiago; Sales Guerra Tsuzuki, Marcos

    2015-01-01

    Multi-Objective Optimization can be used to produce regularized Electrical Impedance Tomography (EIT) images where the weight of the regularization term is not known a priori. This paper proposes a novel Multi-Objective Optimization algorithm based on Simulated Annealing tailored for EIT image reconstruction. Images are reconstructed from experimental data and compared with images from other Multi and Single Objective optimization methods. A significant performance enhancement from traditional techniques can be inferred from the results.

  20. Anti-irritants II: Efficacy against cumulative irritation

    DEFF Research Database (Denmark)

    Andersen, Flemming; Hedegaard, Kathryn; Petersen, Thomas Kongstad

    2006-01-01

    window of opportunity in which to demonstrate efficacy. Therefore, the effect of AI was studied in a cumulative irritation model by inducing irritant dermatitis with 10 min daily exposures for 5+4 days (no irritation on weekend) to 1% sodium lauryl sulfate on the right and 20% nonanoic acid on the left...

  1. The MOAHLFA index of irritant sodium lauryl sulfate reactions: first results of a multicentre study on routine sodium lauryl sulfate patch testing.

    Science.gov (United States)

    Uter, Wolfgang; Geier, Johannes; Becker, Detlef; Brasch, Jochen; Löffler, Harald

    2004-01-01

    In a multicentre study of the German Contact Dermatitis Research Group, sodium lauryl sulfate (SLS) 0.25% and 0.5% aq. has been added to routine allergen patch tests to assess its properties as a convenient diagnostic indicator of individual susceptibility to irritation at the time of patch testing. Previous studies indicated that irritant SLS reactivity may be related to individual factors such as age and sex. As these factors are, in turn, among the important predictors of contact allergy to many allergens, e.g. summarized in the 'MOAHLFA index', the impact of the MOAHLFA factors on irritant SLS patch test reactivity, and thus a potential for confounding, was assessed in the 5971 participating patients. As a result of 2 logistic regression analyses with an irritant reaction to 0.25% and 0.5% SLS, respectively, as outcome, male sex was identified as a relatively weak but significant risk factor (OR 1.38), while age 40 years or older was an even weaker risk factor (OR 1.22 and 1.15, respectively). Upon detailed analysis, no clear age gradient could, however, be identified. 1-day exposure time almost halved the odds of an irritant SLS reaction. In conclusion, this type of SLS patch test can be regarded as robust, indicating individual irritability relatively independent from the individual factors analysed here.

  2. SPECTROSCOPIC ANALYSIS OF AN EIT WAVE/DIMMING OBSERVED BY HINODE/EIS

    International Nuclear Information System (INIS)

    Chen, F.; Ding, M. D.; Chen, P. F.

    2010-01-01

    EUV Imaging Telescope (EIT) waves are a wavelike phenomenon propagating outward from the coronal mass ejection source region, with expanding dimmings following behind. We present a spectroscopic study of an EIT wave/dimming event observed by the Hinode/Extreme-ultraviolet Imaging Spectrometer. Although the identification of the wave front is somewhat affected by the pre-existing loop structures, the expanding dimming is well defined. We investigate the line intensity, width, and Doppler velocity for four EUV lines. In addition to the significant blueshift implying plasma outflows in the dimming region as revealed in previous studies, we find that the widths of all four spectral lines increase at the outer edge of the dimmings. We illustrate that this feature can be well explained by the field line stretching model, which claims that EIT waves are apparently moving brightenings that are generated by the successive stretching of the closed field lines.

  3. Catch-up validation study of an in vitro skin irritation test method based on an open source reconstructed epidermis (phase II).

    Science.gov (United States)

    Groeber, F; Schober, L; Schmid, F F; Traube, A; Kolbus-Hernandez, S; Daton, K; Hoffmann, S; Petersohn, D; Schäfer-Korting, M; Walles, H; Mewes, K R

    2016-10-01

    To replace the Draize skin irritation assay (OECD guideline 404) several test methods based on reconstructed human epidermis (RHE) have been developed and were adopted in the OECD test guideline 439. However, all validated test methods in the guideline are linked to RHE provided by only three companies. Thus, the availability of these test models is dependent on the commercial interest of the producer. To overcome this limitation and thus to increase the accessibility of in vitro skin irritation testing, an open source reconstructed epidermis (OS-REp) was introduced. To demonstrate the capacity of the OS-REp in regulatory risk assessment, a catch-up validation study was performed. The participating laboratories used in-house generated OS-REp to assess the set of 20 reference substances according to the performance standards amending the OECD test guideline 439. Testing was performed under blinded conditions. The within-laboratory reproducibility of 87% and the inter-laboratory reproducibility of 85% prove a high reliability of irritancy testing using the OS-REp protocol. In addition, the prediction capacity was with an accuracy of 80% comparable to previous published RHE based test protocols. Taken together the results indicate that the OS-REp test method can be used as a standalone alternative skin irritation test replacing the OECD test guideline 404. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. The bright-bright and bright-dark mode coupling-based planar metamaterial for plasmonic EIT-like effect

    Science.gov (United States)

    Yu, Wei; Meng, Hongyun; Chen, Zhangjie; Li, Xianping; Zhang, Xing; Wang, Faqiang; Wei, Zhongchao; Tan, Chunhua; Huang, Xuguang; Li, Shuti

    2018-05-01

    In this paper, we propose a novel planar metamaterial structure for the electromagnetically induced transparency (EIT)-like effect, which consists of a split-ring resonator (SRR) and a pair of metal strips. The simulated results indicate that a single transparency window can be realized in the symmetry situation, which originates from the bright-bright mode coupling. Further, a dual-band EIT-like effect can be achieved in the asymmetry situation, which is due to the bright-bright mode coupling and bright-dark mode coupling, respectively. Different EIT-like effect can be simultaneously achieved in the proposed structure with the different situations. It is of certain significance for the study of EIT-like effect.

  5. A GREIT-type linear reconstruction algorithm for EIT using eigenimages

    International Nuclear Information System (INIS)

    Antink, Christoph Hoog; Pikkemaat, Robert; Leonhardt, Steffen

    2013-01-01

    Reconstruction in electrical impedance tomography (EIT) is a nonlinear, ill-posed inverse problem. Based on point-shaped training and evaluation data, the 'Graz consensus Reconstruction algorithm for EIT' (GREIT) constitutes a universal, homogenous method. While this is a very reasonable approach to the general problem, we ask the question if an optimized reconstruction method for a specific application of EIT, i.e. thoracic imaging, can be found. Instead of point-shaped training data we propose to use spatially extended training data consisting of eigenimages. To evaluate the quality of reconstruction of the proposed approach, figures of merit (FOMs) derived from the ones used in GREIT are developed. For the application of thoracic imaging, lung-shapes were segmented from a publicly available CT-database (www.dir-lab.com) and used to calculate the novel FOMs. With those, the general feasibility of using eigenimages is demonstrated and compared to the standard approach. In addition, it is shown that by using different sets of training data, the creation of an individually optimized linear method of reconstruction is possible.

  6. The determination of the irritancy potential of surfactants using various methods of assessment.

    Science.gov (United States)

    Ciuchta, H P; Dodd, K T

    1978-01-01

    Several animal irritancy test methods whose criteria include sensory response, pain/discomfort or tissue damage were evaluated as to their ability to assess relative irritancy potential of the following surfactants: sodium lauryl polyether (12) sulfate (SLES), Miranol C2M (MC2M), Miranol MHT (MMHT), sodium coco methyl tauride (SCMT), triethanolamine lauryl sulfate (TEALS), ammonium lauryl sulfate (ALS) and sodium lauryl sulfate (SLS). Data from the mouse upper respiratory tract and mouse writhing tests indicated that SLES, MC2M and MMHT were the least irritating and SLS, ALS and TEALS were the most irritating. The blepharospasm test did not lend itself to this type of evaluation because sequential instillation of the surfactants produced eye anesthesia. Data from the Draize eye test indicated that SLES was the least irritating while MC2M was slightly more irritating. All other surfactants were equally irritating. The Draize skin test results showed that SLES again was the least irritating at all concentrations tested and that SLS and ALS along with TEALS and SCMT were the most irritating.

  7. Reconstruction of electrical impedance tomography (EIT) images based on the expectation maximum (EM) method.

    Science.gov (United States)

    Wang, Qi; Wang, Huaxiang; Cui, Ziqiang; Yang, Chengyi

    2012-11-01

    Electrical impedance tomography (EIT) calculates the internal conductivity distribution within a body using electrical contact measurements. The image reconstruction for EIT is an inverse problem, which is both non-linear and ill-posed. The traditional regularization method cannot avoid introducing negative values in the solution. The negativity of the solution produces artifacts in reconstructed images in presence of noise. A statistical method, namely, the expectation maximization (EM) method, is used to solve the inverse problem for EIT in this paper. The mathematical model of EIT is transformed to the non-negatively constrained likelihood minimization problem. The solution is obtained by the gradient projection-reduced Newton (GPRN) iteration method. This paper also discusses the strategies of choosing parameters. Simulation and experimental results indicate that the reconstructed images with higher quality can be obtained by the EM method, compared with the traditional Tikhonov and conjugate gradient (CG) methods, even with non-negative processing. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    Science.gov (United States)

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Direct imaging of slow, stored and stationary EIT polaritons

    Science.gov (United States)

    Campbell, Geoff T.; Cho, Young-Wook; Su, Jian; Everett, Jesse; Robins, Nicholas; Lam, Ping Koy; Buchler, Ben

    2017-09-01

    Stationary and slow light effects are of great interest for quantum information applications. Using laser-cooled Rb87 atoms, we performed side imaging of our atomic ensemble under slow and stationary light conditions, which allows direct comparison with numerical models. The polaritons were generated using electromagnetically induced transparency (EIT), with stationary light generated using counter-propagating control fields. By controlling the power ratio of the two control fields, we show fine control of the group velocity of the stationary light. We also compare the dynamics of stationary light using monochromatic and bichromatic control fields. Our results show negligible difference between the two situations, in contrast to previous work in EIT-based systems.

  10. Electrical impedance spectroscopy (EIS)-based evaluation of biological tissue phantoms to study multifrequency electrical impedance tomography (Mf-EIT) systems

    KAUST Repository

    Bera, Tushar Kanti

    2016-03-18

    Abstract: Electrical impedance tomography (EIT) phantoms are essential for the calibration, comparison and evaluation of the EIT systems. In EIT, the practical phantoms are typically developed based on inhomogeneities surrounded by a homogeneous background to simulate a suitable conductivity contrast. In multifrequency EIT (Mf-EIT) evaluation, the phantoms must be developed with the materials which have recognizable or distinguishable impedance variations over a wide range of frequencies. In this direction the impedance responses of the saline solution (background) and a number vegetable and fruit tissues (inhomogeneities) are studied with electrical impedance spectroscopy (EIS) and the frequency responses of bioelectrical impedance and conductivity are analyzed. A number of practical phantoms with different tissue inhomogeneities and different inhomogeneity configurations are developed and the multifrequency impedance imaging is studied with the Mf-EIT system to evaluate the phantoms. The conductivity of the vegetable inhomogeneities reconstructed from the EIT imaging is compared with the conductivity values obtained from the EIS studies. Experimental results obtained from multifrequency EIT reconstruction demonstrate that the electrical impedance of all the biological tissues inhomogenity decreases with frequency. The potato tissue phantom produces better impedance image in high frequency ranges compared to the cucumber phantom, because the cucumber impedance at high frequency becomes lesser than that of the potato at the same frequency range. Graphical Abstract: [Figure not available: see fulltext.] © 2016 The Visualization Society of Japan

  11. EIT Crinkles as Evidence for the Breakout Model of Solar Eruptions

    Science.gov (United States)

    Sterling, Alphonse C.; Moore, Ronald L.

    2001-01-01

    We present observations of two homologous flares in NOAA Active Region 8210 occurring on 1998 May 1 and 2, using EUV data from the EUV Imaging Telescope (EIT) on board the Solar and Heliospheric Observatory, high-resolution and high-time cadence images from the soft X-ray telescope on Yohkoh, images or fluxes from the hard X-ray telescope on Yohkoh and the BATSE experiment on board the Compton Gamma Ray Observatory, and Ca(XIX) soft X-ray spectra from the Bragg crystal spectrometer (BCS) on Yohkoh. Magnetograms indicate that the flares occurred in a complex magnetic topology, consisting of an emerging flux region (EFR) sandwiched between a sunspot to the west and a coronal hole to the east. In an earlier study we found that in EIT images, both flaring episodes showed the formation of a crinkle-like pattern of emission (EIT crinkles) occurring in the coronal hole vicinity, well away from a central 'core field' area near the EFR-sunspot boundary. With our expanded data set, here we find that most of the energetic activity occurs in the core region in both events, with some portions of the core brightening shortly after the onset of the EIT crinkles, and other regions of the core brightening several minutes later, coincident with a burst of hard X-rays; there are no obvious core brightenings prior to the onset of the EIT crinkles. These timings are consistent with the 'breakout model' of solar eruptions, whereby the emerging flux is initially constrained by a system of overlying magnetic field lines, and is able to erupt only after an opening develops in the overlying fields as a consequence of magnetic reconnection at a magnetic null point. In our case, the EIT crinkles would be a signature of this pre-impulsive phase magnetic reconnection, and brightening of the core only occurs after the core fields begin to escape through the newly created opening in the overlying fields. Morphology in soft X-ray images and properties in hard X-rays differ between the two events

  12. UNCOVERING THE WAVE NATURE OF THE EIT WAVE FOR THE 2010 JANUARY 17 EVENT THROUGH ITS CORRELATION TO THE BACKGROUND MAGNETOSONIC SPEED

    International Nuclear Information System (INIS)

    Zhao, X. H.; Feng, X. S.; Jiang, C. W.; Wu, S. T.; Wang, A. H.; Vourlidas, A.

    2011-01-01

    An EIT wave, which typically appears as a diffuse brightening that propagates across the solar disk, is one of the major discoveries of the Extreme ultraviolet Imaging Telescope on board the Solar and Heliospheric Observatory. However, the physical nature of the so-called EIT wave continues to be debated. In order to understand the relationship between an EIT wave and its associated coronal wave front, we investigate the morphology and kinematics of the coronal mass ejection (CME)-EIT wave event that occurred on 2010 January 17. Using the observations of the SECCHI EUVI, COR1, and COR2 instruments on board the Solar Terrestrial Relations Observation-B, we track the shape and movements of the CME fronts along different radial directions to a distance of about 15 solar radii (R s ); for the EIT wave, we determine the propagation of the wave front on the solar surface along different propagating paths. The relation between the EIT wave speed, the CME speed, and the local fast-mode characteristic speed is also investigated. Our results demonstrate that the propagation of the CME front is much faster than that of the EIT wave on the solar surface, and that both the CME front and the EIT wave propagate faster than the fast-mode speed in their local environments. Specifically, we show a significant positive correlation between the EIT wave speed and the local fast-mode wave speed in the propagation paths of the EIT wave. Our findings support that the EIT wave under study is a fast-mode magnetohydrodynamic wave.

  13. Correcting electrode modelling errors in EIT on realistic 3D head models.

    Science.gov (United States)

    Jehl, Markus; Avery, James; Malone, Emma; Holder, David; Betcke, Timo

    2015-12-01

    Electrical impedance tomography (EIT) is a promising medical imaging technique which could aid differentiation of haemorrhagic from ischaemic stroke in an ambulance. One challenge in EIT is the ill-posed nature of the image reconstruction, i.e., that small measurement or modelling errors can result in large image artefacts. It is therefore important that reconstruction algorithms are improved with regard to stability to modelling errors. We identify that wrongly modelled electrode positions constitute one of the biggest sources of image artefacts in head EIT. Therefore, the use of the Fréchet derivative on the electrode boundaries in a realistic three-dimensional head model is investigated, in order to reconstruct electrode movements simultaneously to conductivity changes. We show a fast implementation and analyse the performance of electrode position reconstructions in time-difference and absolute imaging for simulated and experimental voltages. Reconstructing the electrode positions and conductivities simultaneously increased the image quality significantly in the presence of electrode movement.

  14. EIT Imaging of admittivities with a D-bar method and spatial prior: experimental results for absolute and difference imaging.

    Science.gov (United States)

    Hamilton, S J

    2017-05-22

    Electrical impedance tomography (EIT) is an emerging imaging modality that uses harmless electrical measurements taken on electrodes at a body's surface to recover information about the internal electrical conductivity and or permittivity. The image reconstruction task of EIT is a highly nonlinear inverse problem that is sensitive to noise and modeling errors making the image reconstruction task challenging. D-bar methods solve the nonlinear problem directly, bypassing the need for detailed and time-intensive forward models, to provide absolute (static) as well as time-difference EIT images. Coupling the D-bar methodology with the inclusion of high confidence a priori data results in a noise-robust regularized image reconstruction method. In this work, the a priori D-bar method for complex admittivities is demonstrated effective on experimental tank data for absolute imaging for the first time. Additionally, the method is adjusted for, and tested on, time-difference imaging scenarios. The ability of the method to be used for conductivity, permittivity, absolute as well as time-difference imaging provides the user with great flexibility without a high computational cost.

  15. Mutual information as a measure of reconstruction quality in 3D dynamic lung EIT

    International Nuclear Information System (INIS)

    Crabb, M G; Lionheart, W R B; Davidson, J L; Wright, P; McCann, H; Little, R; Naish, J H; Parker, G J M; Kikinis, R

    2013-01-01

    We report on a pilot study with healthy subjects who had an MR scan in addition to EIT data acquired with the Manchester fEITER system. The MR images are used to inform the external shape of a 3D EIT reconstruction model of the thorax, and small changes in the boundary that occur during respiration are addressed by incorporating the sensitivity with respect to boundary shape into a robust reconstruction algorithm. A quantitative comparison of the image quality for different EIT reconstructions is achieved through calculation of their mutual information with a segmented MR image. A shape corrected reconstruction algorithm reduces boundary artefacts relative to a standard reconstruction, and has a greater mutual information of approximately 4% with the segmented MR image.

  16. Observations of solar wave/instability phenomena as imaged by EIT/SOHO, TRACE and Yohkoh/SXT

    International Nuclear Information System (INIS)

    Berghmans, D.; McKenzie, D.

    2000-01-01

    On May 13 1998, active region NOAA 8218 was observed in the context of the SOHO/JOP80 campaign by an array of 8 different ground-based and space-born instruments. The emphasis was set on imaging of small-scale dynamics in this relatively small but rapidly evolving AR. In particular, SOHO/EIT (195 Aa), TRACE (171 Aa) and YOHKOH/SXT produced subfield image sequences at their respective highest possible rates. We searched for wave and instability phenomena by using an automated recognition scheme. This result in a wide inventory of propagating disturbances and localized transient brightenings. By comparing the soft X-ray signature as recorded by SXT with the EUV-signature as collected by EIT and TRACE, we are able to distinguish between various types of active region transients. As such we find that the strongest brightenings observed by EIT are indeed the EUV counterparts of the previously reported ARTBs seen by SXT. Weaker brightenings seen by EIT do often not have an X-ray counterpart. Moreover, in an extended system of faint quasi-open loops, we find propagating disturbances, with speeds of the order of 100 km/s, both in EIT and TRACE images. These are interpreted as sonic perturbations. The brightenings will be discussed in this paper while the propagating disturbances are described in the presentation by Eva Robbrecht at this conference

  17. Preparation of irritant polymer samples for an in vitro round robin study.

    NARCIS (Netherlands)

    Coleman, Kelly P; Grailer, Thomas P; McNamara, Lori R; Rollins, Beau L; Christiano, Nicholas J; Kandárová, Helena; De Jong, Wim H

    2018-01-01

    A round robin study using reconstructed human epidermis (RhE) tissues was conducted to test medical device polymer extracts for skin irritation potential. Test samples were four irritant and three non-irritant medical device polymers. Five of these polymer samples were developed and two were

  18. Observation of the widening and shifting of EIT windows in a quasi-degenerate two-level atomic system

    International Nuclear Information System (INIS)

    Dong Yabin; Zhang Junxiang; Wang Haihong; Gao Jiangrui

    2006-01-01

    Widening and shifting the EIT windows in a closed transition F e = 2 ↔ F g = 3 driven by linearly polarized coupling lights and probed by circularly polarized lights are observed in Cs vapour. It is shown that by increasing the strength of magnetic field i.e. Zeeman splitting in the upper and lower levels, the electromagnetically induced transparency window is divided into two windows and the EIT maxima are shifted away from the zero detuning. In the contrast, if the strength of the magnetic field is fixed and the Rabi frequency of coupling beam is increased, the two EIT windows become wider, and the gap between the two EIT windows becomes smaller and smaller. These effects are also theoretically discussed and they are qualitatively in agreement with the theoretical results

  19. Multi-frequency time-difference complex conductivity imaging of canine and human lungs using the KHU Mark1 EIT system

    International Nuclear Information System (INIS)

    Kuen, Jihyeon; Woo, Eung Je; Seo, Jin Keun

    2009-01-01

    We evaluated the performance of the lately developed electrical impedance tomography (EIT) system KHU Mark1 through time-difference imaging experiments of canine and human lungs. We derived a multi-frequency time-difference EIT (mftdEIT) image reconstruction algorithm based on the concept of the equivalent homogeneous complex conductivity. Imaging experiments were carried out at three different frequencies of 10, 50 and 100 kHz with three different postures of right lateral, sitting (or prone) and left lateral positions. For three normal canine subjects, we controlled the ventilation using a ventilator at three tidal volumes of 100, 150 and 200 ml. Three human subjects were asked to breath spontaneously at a normal tidal volume. Real- and imaginary-part images of the canine and human lungs were reconstructed at three frequencies and three postures. Images showed different stages of breathing cycles and we could interpret them based on the understanding of the proposed mftdEIT image reconstruction algorithm. Time series of images were further analyzed by using the functional EIT (fEIT) method. Images of human subjects showed the gravity effect on air distribution in two lungs. In the canine subjects, the morphological change seems to dominate the gravity effect. We could also observe that two different types of ventilation should have affected the results. The KHU Mark1 EIT system is expected to provide reliable mftdEIT images of the human lungs. In terms of the image reconstruction algorithm, it would be worthwhile including the effects of three-dimensional current flows inside the human thorax. We suggest clinical trials of the KHU Mark1 for pulmonary applications

  20. Multi-frequency time-difference complex conductivity imaging of canine and human lungs using the KHU Mark1 EIT system.

    Science.gov (United States)

    Kuen, Jihyeon; Woo, Eung Je; Seo, Jin Keun

    2009-06-01

    We evaluated the performance of the lately developed electrical impedance tomography (EIT) system KHU Mark1 through time-difference imaging experiments of canine and human lungs. We derived a multi-frequency time-difference EIT (mftdEIT) image reconstruction algorithm based on the concept of the equivalent homogeneous complex conductivity. Imaging experiments were carried out at three different frequencies of 10, 50 and 100 kHz with three different postures of right lateral, sitting (or prone) and left lateral positions. For three normal canine subjects, we controlled the ventilation using a ventilator at three tidal volumes of 100, 150 and 200 ml. Three human subjects were asked to breath spontaneously at a normal tidal volume. Real- and imaginary-part images of the canine and human lungs were reconstructed at three frequencies and three postures. Images showed different stages of breathing cycles and we could interpret them based on the understanding of the proposed mftdEIT image reconstruction algorithm. Time series of images were further analyzed by using the functional EIT (fEIT) method. Images of human subjects showed the gravity effect on air distribution in two lungs. In the canine subjects, the morphological change seems to dominate the gravity effect. We could also observe that two different types of ventilation should have affected the results. The KHU Mark1 EIT system is expected to provide reliable mftdEIT images of the human lungs. In terms of the image reconstruction algorithm, it would be worthwhile including the effects of three-dimensional current flows inside the human thorax. We suggest clinical trials of the KHU Mark1 for pulmonary applications.

  1. All-optical tuning of EIT-like dielectric metasurfaces by means of chalcogenide phase change materials.

    Science.gov (United States)

    Petronijevic, E; Sibilia, C

    2016-12-26

    Electromagnetically induced transparency (EIT) is a pump-induced narrowband transparency window within an absorption line of the probe beam spectrum in an atomic system. In this paper we propose a way to bring together the all-dielectric metamaterials to have EIT-like effects and to optically tune the response by hybridizing them with a layer of a phase change material. We propose a design of the metamaterial based on Si nanoresonators that can support an EIT-like resonant response. On the top of the resonators we consider a thin layer of a chalcogenide phase change material, which we will use to tune the optical response. Our choice is Ge2Sb2Te5 (GST), since it has two stable phases at room temperature, namely amorphous and crystalline, between which it can be switched quickly, nonvolatively and reversibly, sustaining a large number of switching cycles. They differ in optical properties, while still having moderately low losses in telecom range. Since such dielectric resonators do not have non-radiative losses of metals around 1550nm, they can lead to a high-Q factor of the EIT-like response in this range. Firstly, we optimize the starting structure so that it gives an EIT-like response at 1550 nm when the GST layer is in the amorphous state. Our starting design uses glass as a substrate, but we also consider implementation in SOI technology. If we then switch the thin layer of GST to its crystalline phase, which has higher losses, the EIT-like response is red shifted, providing around 10:1 contrast at 1550nm. This reversible tuning can be done with an ns visible pulsed laser. We discuss the results of the simulation of the dielectric metasurface for different configurations and the tuning possibility.

  2. [Correlation of the microbiota and intestinal mucosa in the pathophysiology and treatment of irritable bowel, irritable eye, and irritable mind syndrome].

    Science.gov (United States)

    Fehér, János; Kovács, Illés; Pacella, Elena; Radák, Zsolt

    2014-09-14

    Accumulating clinical evidence supports co-morbidity of irritable bowel, irritable eye and irritable mind symptoms. Furthermore, perturbation of the microbiota-host symbiosis (dysbiosis) is considered a common pathogenic mechanism connecting gastrointestinal, ocular and neuropsychiatric symptoms. Consequently, maintaining or restoring microbiota-host symbiosis represents a new approach to treat these symptoms or to prevent their relapses. Current treatment approach assigned a primary role to live probiotics alone or in combination with prebiotics to enhance colonization of beneficial bacteria and to strengthen the symbiosis. However, several papers showed major benefits of heat-killed probiotics as compared to their live counterparts on both intestinal and systemic symptoms. Recently, in addition to killing probiotics, in a proof of concept study lysates (fragments) of probiotics in combination with vitamins A, B, D and omega 3 fatty acids were successfully tested. These findings suggested a conceptual change in the approach addressed to both the microbiota and host as targets for intervention.

  3. Incorporating a Spatial Prior into Nonlinear D-Bar EIT Imaging for Complex Admittivities.

    Science.gov (United States)

    Hamilton, Sarah J; Mueller, J L; Alsaker, M

    2017-02-01

    Electrical Impedance Tomography (EIT) aims to recover the internal conductivity and permittivity distributions of a body from electrical measurements taken on electrodes on the surface of the body. The reconstruction task is a severely ill-posed nonlinear inverse problem that is highly sensitive to measurement noise and modeling errors. Regularized D-bar methods have shown great promise in producing noise-robust algorithms by employing a low-pass filtering of nonlinear (nonphysical) Fourier transform data specific to the EIT problem. Including prior data with the approximate locations of major organ boundaries in the scattering transform provides a means of extending the radius of the low-pass filter to include higher frequency components in the reconstruction, in particular, features that are known with high confidence. This information is additionally included in the system of D-bar equations with an independent regularization parameter from that of the extended scattering transform. In this paper, this approach is used in the 2-D D-bar method for admittivity (conductivity as well as permittivity) EIT imaging. Noise-robust reconstructions are presented for simulated EIT data on chest-shaped phantoms with a simulated pneumothorax and pleural effusion. No assumption of the pathology is used in the construction of the prior, yet the method still produces significant enhancements of the underlying pathology (pneumothorax or pleural effusion) even in the presence of strong noise.

  4. Fused-data transrectal EIT for prostate cancer imaging.

    Science.gov (United States)

    Murphy, Ethan K; Wu, Xiaotian; Halter, Ryan J

    2018-05-25

    Prostate cancer is a significant problem affecting 1 in 7 men. Unfortunately, the diagnostic gold-standard of ultrasound-guided biopsy misses 10%-30% of all cancers. The objective of this study was to develop an electrical impedance tomography (EIT) approach that has the potential to image the entire prostate using multiple impedance measurements recorded between electrodes integrated onto an end-fired transrectal ultrasound (TRUS) device and a biopsy probe (BP). Simulations and sensitivity analyses were used to investigate the best combination of electrodes, and measured tank experiments were used to evaluate a fused-data transrectal EIT (fd-TREIT) and BP approach. Simulations and sensitivity analysis revealed that (1) TREIT measurements are not sufficiently sensitive to image the whole prostate, (2) the combination of TREIT  +  BP measurements increases the sensitive region of TREIT-only measurements by 12×, and (3) the fusion of multiple TREIT  +  BP measurements collected during a routine or customized 12-core biopsy procedure can cover up to 76.1% or 94.1% of a nominal 50 cm 3 prostate, respectively. Three measured tank experiments of the fd-TREIT  +  BP approach successfully and accurately recovered the positions of 2-3 metal or plastic inclusions. The measured tank experiments represent important steps in the development of an algorithm that can combine EIT from multiple locations and from multiple probes-data that could be collected during a routine TRUS-guided 12-core biopsy. Overall, this result is a step towards a clinically deployable impedance imaging approach to scanning the entire prostate, which could significantly help to improve prostate cancer diagnosis.

  5. EIT-based all-optical switching and cross-phase modulation under the influence of four-wave mixing.

    Science.gov (United States)

    Lee, Meng-Jung; Chen, Yi-Hsin; Wang, I-Chung; Yu, Ite A

    2012-05-07

    All-optical switching (AOS) or cross-phase modulation (XPM) based on the effect of electromagnetically induced transparency (EIT) makes one photon switched or phase-modulated by another possible. The existence of four-wave mixing (FWM) process greatly diminishes the switching or phase-modulation efficiency and hinders the single-photon operation. We proposed and experimentally demonstrated an idea that with an optimum detuning the EIT-based AOS can be completely intact even under the influence of FWM. The results of the work can be directly applied to the EIT-based XPM. Our work makes the AOS and XPM schemes more flexible and the single-photon operation possible in FWM-allowed systems.

  6. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests

    OpenAIRE

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2015-01-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Met...

  7. Reconstruction of conductivity changes and electrode movements based on EIT temporal sequences

    International Nuclear Information System (INIS)

    Dai, Tao; Gómez-Laberge, Camille; Adler, Andy

    2008-01-01

    Electrical impedance tomography (EIT) reconstructs a conductivity change image within a body from electrical measurements on the body surface; while it has relatively low spatial resolution, it has a high temporal resolution. One key difficulty with EIT measurements is due to the movement and position uncertainty of the electrodes, especially due to breathing and posture change. In this paper, we develop an approach to reconstruct both the conductivity change image and the electrode movements from the temporal sequence of EIT measurements. Since both the conductivity change and electrode movement are slow with respect to the data frame rate, there are significant temporal correlations which we formulate as priors for the regularized image reconstruction model. Image reconstruction is posed in terms of a regularization matrix and a Jacobian matrix which are augmented for the conductivity change and electrode movement, and then further augmented to concatenate the d previous and future frames. Results are shown for simulation, phantom and human data, and show that the proposed algorithm yields improved resolution and noise performance in comparison to a conventional one-step reconstruction method

  8. Imaging and quantification of anomaly volume using an eight-electrode 'hemiarray' EIT reconstruction method.

    Science.gov (United States)

    Sadleir, R J; Zhang, S U; Tucker, A S; Oh, Sungho

    2008-08-01

    Electrical impedance tomography (EIT) is particularly well-suited to applications where its portability, rapid acquisition speed and sensitivity give it a practical advantage over other monitoring or imaging systems. An EIT system's patient interface can potentially be adapted to match the target environment, and thereby increase its utility. It may thus be appropriate to use different electrode positions from those conventionally used in EIT in these cases. One application that may require this is the use of EIT on emergency medicine patients; in particular those who have suffered blunt abdominal trauma. In patients who have suffered major trauma, it is desirable to minimize the risk of spinal cord injury by avoiding lifting them. To adapt EIT to this requirement, we devised and evaluated a new electrode topology (the 'hemiarray') which comprises a set of eight electrodes placed only on the subject's anterior surface. Images were obtained using a two-dimensional sensitivity matrix and weighted singular value decomposition reconstruction. The hemiarray method's ability to quantify bleeding was evaluated by comparing its performance with conventional 2D reconstruction methods using data gathered from a saline phantom. We found that without applying corrections to reconstructed images it was possible to estimate blood volume in a two-dimensional hemiarray case with an uncertainty of around 27 ml. In an approximately 3D hemiarray case, volume prediction was possible with a maximum uncertainty of around 38 ml in the centre of the electrode plane. After application of a QI normalizing filter, average uncertainties in a two-dimensional hemiarray case were reduced to about 15 ml. Uncertainties in the approximate 3D case were reduced to about 30 ml.

  9. Respiratory irritation by trimellitic anhydride in Brown Norway and Wistar rats

    NARCIS (Netherlands)

    Arts, J.H.E.; Koning, M.W.de; Bloksma, N.; Kuper, C.F.

    2001-01-01

    Several acid anhydrides are known for their sensitizing and irritative properties. Since both irritation and respiratory allergy can cause changes of lung function, proper testing of allergen-dependent effects on the respiratory tract requires knowledge of the respiratory irritant effects. To study

  10. A unified approach for EIT imaging of regional overdistension and atelectasis in acute lung injury.

    Science.gov (United States)

    Gómez-Laberge, Camille; Arnold, John H; Wolf, Gerhard K

    2012-03-01

    Patients with acute lung injury or acute respiratory distress syndrome (ALI/ARDS) are vulnerable to ventilator-induced lung injury. Although this syndrome affects the lung heterogeneously, mechanical ventilation is not guided by regional indicators of potential lung injury. We used electrical impedance tomography (EIT) to estimate the extent of regional lung overdistension and atelectasis during mechanical ventilation. Techniques for tidal breath detection, lung identification, and regional compliance estimation were combined with the Graz consensus on EIT lung imaging (GREIT) algorithm. Nine ALI/ARDS patients were monitored during stepwise increases and decreases in airway pressure. Our method detected individual breaths with 96.0% sensitivity and 97.6% specificity. The duration and volume of tidal breaths erred on average by 0.2 s and 5%, respectively. Respiratory system compliance from EIT and ventilator measurements had a correlation coefficient of 0.80. Stepwise increases in pressure could reverse atelectasis in 17% of the lung. At the highest pressures, 73% of the lung became overdistended. During stepwise decreases in pressure, previously-atelectatic regions remained open at sub-baseline pressures. We recommend that the proposed approach be used in collaborative research of EIT-guided ventilation strategies for ALI/ARDS.

  11. MO-F-CAMPUS-I-01: EIT Imaging to Monitor Human Salivary Gland Functionality: A Feasibility Study

    International Nuclear Information System (INIS)

    Kohli, K; Karvat, A; Liu, J; Krishnan, K

    2015-01-01

    Purpose: Clinically, there exists a need to develop a non-invasive technique for monitoring salivary activity. In this study, we investigate the feasibility of a using the electrical conductivity information from Electrical Impedance Tomography (EIT) to monitor salivary flow activity. Methods: To acquire EIT data, eight Ag/AgCl ECG electrodes were placed around the mandible of the subject. An EIT scan was obtained by injecting current at 50 KHz, 0.4 mA through each pair of electrodes and recording voltage across other electrode pairs. The functional conductivity image was obtained through reconstruction of the voltage data, using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) in Matlab. In using EIDORS, forward solution was obtained using a user-defined finite element model shape and inverse solution was obtained using one-step Gaussian solver. EIT scans of volunteer research team members were acquired for three different physiological states: pre-stimulation, stimulation and post-stimulation. For pre-stimulation phase, data were collected in intervals of 5 minutes for 15 minutes. The salivary glands were then stimulated in the subject using lemon and the data were collected immediately. Post-stimulation data were collected at 4 different timings after stimulation. Results: Variations were observed in the electrical conductivity patterns near parotid regions between the pre- and post-stimulation stages. The three images acquired during the 15 minute pre-stimulation phase showed no major changes in the conductivity. Immediately after stimulation, electrical conductivity increased near parotid regions and 15 minutes later slowly returned to pre-stimulation level. Conclusion: In the present study involving human subjects, the change in electrical conductivity pattern shown in the EIT images, acquired at different times with and without stimulation of salivary glands, appeared to be consistent with the change in salivary

  12. MO-F-CAMPUS-I-01: EIT Imaging to Monitor Human Salivary Gland Functionality: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, K; Karvat, A; Liu, J; Krishnan, K [BC Cancer Agency, Surrey, BC (United Kingdom)

    2015-06-15

    Purpose: Clinically, there exists a need to develop a non-invasive technique for monitoring salivary activity. In this study, we investigate the feasibility of a using the electrical conductivity information from Electrical Impedance Tomography (EIT) to monitor salivary flow activity. Methods: To acquire EIT data, eight Ag/AgCl ECG electrodes were placed around the mandible of the subject. An EIT scan was obtained by injecting current at 50 KHz, 0.4 mA through each pair of electrodes and recording voltage across other electrode pairs. The functional conductivity image was obtained through reconstruction of the voltage data, using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) in Matlab. In using EIDORS, forward solution was obtained using a user-defined finite element model shape and inverse solution was obtained using one-step Gaussian solver. EIT scans of volunteer research team members were acquired for three different physiological states: pre-stimulation, stimulation and post-stimulation. For pre-stimulation phase, data were collected in intervals of 5 minutes for 15 minutes. The salivary glands were then stimulated in the subject using lemon and the data were collected immediately. Post-stimulation data were collected at 4 different timings after stimulation. Results: Variations were observed in the electrical conductivity patterns near parotid regions between the pre- and post-stimulation stages. The three images acquired during the 15 minute pre-stimulation phase showed no major changes in the conductivity. Immediately after stimulation, electrical conductivity increased near parotid regions and 15 minutes later slowly returned to pre-stimulation level. Conclusion: In the present study involving human subjects, the change in electrical conductivity pattern shown in the EIT images, acquired at different times with and without stimulation of salivary glands, appeared to be consistent with the change in salivary

  13. VISUAL3D - An EIT network on visualization of geomodels

    Science.gov (United States)

    Bauer, Tobias

    2017-04-01

    When it comes to interpretation of data and understanding of deep geological structures and bodies at different scales then modelling tools and modelling experience is vital for deep exploration. Geomodelling provides a platform for integration of different types of data, including new kinds of information (e.g., new improved measuring methods). EIT Raw Materials, initiated by the EIT (European Institute of Innovation and Technology) and funded by the European Commission, is the largest and strongest consortium in the raw materials sector worldwide. The VISUAL3D network of infrastructure is an initiative by EIT Raw Materials and aims at bringing together partners with 3D-4D-visualisation infrastructure and 3D-4D-modelling experience. The recently formed network collaboration interlinks hardware, software and expert knowledge in modelling visualization and output. A special focus will be the linking of research, education and industry and integrating multi-disciplinary data and to visualize the data in three and four dimensions. By aiding network collaborations we aim at improving the combination of geomodels with differing file formats and data characteristics. This will create an increased competency in modelling visualization and the ability to interchange and communicate models more easily. By combining knowledge and experience in geomodelling with expertise in Virtual Reality visualization partners of EIT Raw Materials but also external parties will have the possibility to visualize, analyze and validate their geomodels in immersive VR-environments. The current network combines partners from universities, research institutes, geological surveys and industry with a strong background in geological 3D-modelling and 3D visualization and comprises: Luleå University of Technology, Geological Survey of Finland, Geological Survey of Denmark and Greenland, TUBA Freiberg, Uppsala University, Geological Survey of France, RWTH Aachen, DMT, KGHM Cuprum, Boliden, Montan

  14. Environmental Protection Agency EIT Procurement Checklist for Section 508 Instructions

    Science.gov (United States)

    Includes examples of items that are considered electronic information technology (EIT), and some that are not, explanations of each exemption and requirement, and how to provide required documentation to justify exemption or undue burden.

  15. Irritancy of antiseptics tested by repeated open exposures on the human skin, evaluated by non-invasive methods

    NARCIS (Netherlands)

    Tupker, RA; Schuur, J; Coenraads, PJ

    1997-01-01

    The aim of the study was to test the irritancy of 6 antiseptics in an open exposure model. The following agents were tested in their normal use concentrations using open exposures, 2x daily for 4 days in 20 subjects: chlorhexidine 4% (CH), chlorhexidine 0.5% in ethanol 70% (CE), ethanol 70% (ET),

  16. Functional validation and comparison framework for EIT lung imaging.

    Science.gov (United States)

    Grychtol, Bartłomiej; Elke, Gunnar; Meybohm, Patrick; Weiler, Norbert; Frerichs, Inéz; Adler, Andy

    2014-01-01

    Electrical impedance tomography (EIT) is an emerging clinical tool for monitoring ventilation distribution in mechanically ventilated patients, for which many image reconstruction algorithms have been suggested. We propose an experimental framework to assess such algorithms with respect to their ability to correctly represent well-defined physiological changes. We defined a set of clinically relevant ventilation conditions and induced them experimentally in 8 pigs by controlling three ventilator settings (tidal volume, positive end-expiratory pressure and the fraction of inspired oxygen). In this way, large and discrete shifts in global and regional lung air content were elicited. We use the framework to compare twelve 2D EIT reconstruction algorithms, including backprojection (the original and still most frequently used algorithm), GREIT (a more recent consensus algorithm for lung imaging), truncated singular value decomposition (TSVD), several variants of the one-step Gauss-Newton approach and two iterative algorithms. We consider the effects of using a 3D finite element model, assuming non-uniform background conductivity, noise modeling, reconstructing for electrode movement, total variation (TV) reconstruction, robust error norms, smoothing priors, and using difference vs. normalized difference data. Our results indicate that, while variation in appearance of images reconstructed from the same data is not negligible, clinically relevant parameters do not vary considerably among the advanced algorithms. Among the analysed algorithms, several advanced algorithms perform well, while some others are significantly worse. Given its vintage and ad-hoc formulation backprojection works surprisingly well, supporting the validity of previous studies in lung EIT.

  17. Functional validation and comparison framework for EIT lung imaging.

    Directory of Open Access Journals (Sweden)

    Bartłomiej Grychtol

    Full Text Available INTRODUCTION: Electrical impedance tomography (EIT is an emerging clinical tool for monitoring ventilation distribution in mechanically ventilated patients, for which many image reconstruction algorithms have been suggested. We propose an experimental framework to assess such algorithms with respect to their ability to correctly represent well-defined physiological changes. We defined a set of clinically relevant ventilation conditions and induced them experimentally in 8 pigs by controlling three ventilator settings (tidal volume, positive end-expiratory pressure and the fraction of inspired oxygen. In this way, large and discrete shifts in global and regional lung air content were elicited. METHODS: We use the framework to compare twelve 2D EIT reconstruction algorithms, including backprojection (the original and still most frequently used algorithm, GREIT (a more recent consensus algorithm for lung imaging, truncated singular value decomposition (TSVD, several variants of the one-step Gauss-Newton approach and two iterative algorithms. We consider the effects of using a 3D finite element model, assuming non-uniform background conductivity, noise modeling, reconstructing for electrode movement, total variation (TV reconstruction, robust error norms, smoothing priors, and using difference vs. normalized difference data. RESULTS AND CONCLUSIONS: Our results indicate that, while variation in appearance of images reconstructed from the same data is not negligible, clinically relevant parameters do not vary considerably among the advanced algorithms. Among the analysed algorithms, several advanced algorithms perform well, while some others are significantly worse. Given its vintage and ad-hoc formulation backprojection works surprisingly well, supporting the validity of previous studies in lung EIT.

  18. Phase division multiplexed EIT for enhanced temporal resolution.

    Science.gov (United States)

    Dowrick, T; Holder, D

    2018-03-29

    The most commonly used EIT paradigm (time division multiplexing) limits the temporal resolution of impedance images due to the need to switch between injection electrodes. Advances have previously been made using frequency division multiplexing (FDM) to increase temporal resolution, but in cases where a fixed range of frequencies is available, such as imaging fast neural activity, an upper limit is placed on the total number of simultaneous injections. The use of phase division multiplexing (PDM) where multiple out of phase signals can be injected at each frequency is investigated to increase temporal resolution. TDM, FDM and PDM were compared in head tank experiments, to compare transfer impedance measurements and spatial resolution between the three techniques. A resistor phantom paradigm was established to investigate the imaging of one-off impedance changes, of magnitude 1% and with durations as low as 500 µs (similar to those seen in nerve bundles), using both PDM and TDM approaches. In head tank experiments, a strong correlation (r  >  0.85 and p  EIT injections.

  19. Additive impairment of the barrier function and irritation by biogenic amines and sodium lauryl sulphate: a controlled in vivo tandem irritation study.

    Science.gov (United States)

    Fluhr, J W; Kelterer, D; Fuchs, S; Kaatz, M; Grieshaber, R; Kleesz, P; Elsner, P

    2005-01-01

    Biogenic amines are potential irritants e.g. in fish-, meat-, milk- and egg-processing professions like cooks, butchers and bakers. The aim of this study was to test the irritative and barrier-disrupting properties of the biogenic amines ammonium hydroxide (AM), dimethylamine (DMA) and trimethylamine (TMA). A repeated sequential irritation of 30 min twice per day was performed over a total of 4 days (tandem repeated irritation test) on the back of 20 healthy volunteers of both sexes with AM, DMA, TMA and sodium lauryl sulphate (SLS). The epidermal barrier function was assessed with a Tewameter TM 210, stratum corneum surface pH was measured with a Skin-pH-Meter 900, inflammation was assessed with a Chromameter CR-300 on the a* axis for redness and a visual score was recorded. All tested biogenic amines (AM, DMA and TMA) induced a barrier disruption and a pH increase paralleled with a 1-day-delayed onset of inflammatory signs. These effects were further enhanced and accelerated by a sequential application of SLS together with the biogenic amines, and inflammation occurred earlier than with the single compounds. Acetic acid (AA) in contrast did only show mild barrier disruption and no significant inflammatory signs. Our system allowed a ranking of the different compounds in their irritative potential in the tandem irritation with SLS: SLS > NaOH > TMA > AA > AM > DMA. The results are suggestive that in the food-processing industry the simultaneous contact with biogenic amines and harmful detergents like SLS should be minimized. Copyright 2005 S. Karger AG, Basel.

  20. Electromagnetically induced transparency (EIT)-like transmission in side-coupled complementary split-ring resonators.

    Science.gov (United States)

    Guo, Yinghui; Yan, Lianshan; Pan, Wei; Luo, Bin; Wen, Kunhua; Guo, Zhen; Luo, Xiangang

    2012-10-22

    We investigate a plasmonic waveguide system based on side-coupled complementary split-ring resonators (CSRR), which exhibits electromagnetically induced transparency (EIT)-like transmission. LC resonance model is utilized to explain the electromagnetic responses of CSRR, which is verified by simulation results of finite difference time domain method. The electromagnetic responses of CSRR can be flexible handled by changing the asymmetry degree of the structure and the width of the metallic baffles. Cascaded CSRRs also have been studied to obtain EIT-like transmission at visible and near-infrared region, simultaneously.

  1. Non-invasive monitoring of pulmonary artery pressure from timing information by EIT: experimental evaluation during induced hypoxia.

    Science.gov (United States)

    Proença, Martin; Braun, Fabian; Solà, Josep; Adler, Andy; Lemay, Mathieu; Thiran, Jean-Philippe; Rimoldi, Stefano F

    2016-06-01

    Monitoring of pulmonary artery pressure (PAP) in pulmonary hypertensive patients is currently limited to invasive solutions. We investigate a novel non-invasive approach for continuous monitoring of PAP, based on electrical impedance tomography (EIT), a safe, low-cost and non-invasive imaging technology. EIT recordings were performed in three healthy subjects undergoing hypoxia-induced PAP variations. The pulmonary pulse arrival time (PAT), a timing parameter physiologically linked to the PAP, was automatically calculated from the EIT signals. Values were compared to systolic PAP values from Doppler echocardiography, and yielded strong correlation scores ([Formula: see text]) for all three subjects. Results suggest the feasibility of non-invasive, unsupervised monitoring of PAP.

  2. The use of the Kalman filter in the automated segmentation of EIT lung images

    International Nuclear Information System (INIS)

    Zifan, A; Chapman, B E; Liatsis, P

    2013-01-01

    In this paper, we present a new pipeline for the fast and accurate segmentation of impedance images of the lungs using electrical impedance tomography (EIT). EIT is an emerging, promising, non-invasive imaging modality that produces real-time, low spatial but high temporal resolution images of impedance inside a body. Recovering impedance itself constitutes a nonlinear ill-posed inverse problem, therefore the problem is usually linearized, which produces impedance-change images, rather than static impedance ones. Such images are highly blurry and fuzzy along object boundaries. We provide a mathematical reasoning behind the high suitability of the Kalman filter when it comes to segmenting and tracking conductivity changes in EIT lung images. Next, we use a two-fold approach to tackle the segmentation problem. First, we construct a global lung shape to restrict the search region of the Kalman filter. Next, we proceed with augmenting the Kalman filter by incorporating an adaptive foreground detection system to provide the boundary contours for the Kalman filter to carry out the tracking of the conductivity changes as the lungs undergo deformation in a respiratory cycle. The proposed method has been validated by using performance statistics such as misclassified area, and false positive rate, and compared to previous approaches. The results show that the proposed automated method can be a fast and reliable segmentation tool for EIT imaging. (paper)

  3. The use of the Kalman filter in the automated segmentation of EIT lung images.

    Science.gov (United States)

    Zifan, A; Liatsis, P; Chapman, B E

    2013-06-01

    In this paper, we present a new pipeline for the fast and accurate segmentation of impedance images of the lungs using electrical impedance tomography (EIT). EIT is an emerging, promising, non-invasive imaging modality that produces real-time, low spatial but high temporal resolution images of impedance inside a body. Recovering impedance itself constitutes a nonlinear ill-posed inverse problem, therefore the problem is usually linearized, which produces impedance-change images, rather than static impedance ones. Such images are highly blurry and fuzzy along object boundaries. We provide a mathematical reasoning behind the high suitability of the Kalman filter when it comes to segmenting and tracking conductivity changes in EIT lung images. Next, we use a two-fold approach to tackle the segmentation problem. First, we construct a global lung shape to restrict the search region of the Kalman filter. Next, we proceed with augmenting the Kalman filter by incorporating an adaptive foreground detection system to provide the boundary contours for the Kalman filter to carry out the tracking of the conductivity changes as the lungs undergo deformation in a respiratory cycle. The proposed method has been validated by using performance statistics such as misclassified area, and false positive rate, and compared to previous approaches. The results show that the proposed automated method can be a fast and reliable segmentation tool for EIT imaging.

  4. Reconstruction of a piecewise constant conductivity on a polygonal partition via shape optimization in EIT

    Science.gov (United States)

    Beretta, Elena; Micheletti, Stefano; Perotto, Simona; Santacesaria, Matteo

    2018-01-01

    In this paper, we develop a shape optimization-based algorithm for the electrical impedance tomography (EIT) problem of determining a piecewise constant conductivity on a polygonal partition from boundary measurements. The key tool is to use a distributed shape derivative of a suitable cost functional with respect to movements of the partition. Numerical simulations showing the robustness and accuracy of the method are presented for simulated test cases in two dimensions.

  5. A FPGA-Based Broadband EIT System for Complex Bioimpedance Measurements—Design and Performance Estimation

    Directory of Open Access Journals (Sweden)

    Roman Kusche

    2015-07-01

    Full Text Available Electrical impedance tomography (EIT is an imaging method that is able to estimate the electrical conductivity distribution of living tissue. This work presents a field programmable gate array (FPGA-based multi-frequency EIT system for complex, time-resolved bioimpedance measurements. The system has the capability to work with measurement setups with up to 16 current electrodes and 16 voltage electrodes. The excitation current has a range of about 10 µA to 5 mA, whereas the sinusoidal signal used for excitation can have a frequency of up to 500 kHz. Additionally, the usage of a chirp or rectangular signal excitation is possible. Furthermore, the described system has a sample rate of up to 3480 impedance spectra per second (ISPS. The performance of the EIT system is demonstrated with a resistor-based phantom and tank phantoms. Additionally, first measurements taken from the human thorax during a breathing cycle are presented.

  6. Occupational irritant contact dermatitis diagnosed by analysis of contact irritants and allergens in the work environment.

    Science.gov (United States)

    Friis, Ulrik F; Menné, Torkil; Schwensen, Jakob F; Flyvholm, Mari-Ann; Bonde, Jens P E; Johansen, Jeanne D

    2014-12-01

    Irritant contact dermatitis (ICD) is a common diagnosis in patients with occupational contact dermatitis (OCD). Studies are lacking on the usefulness of material safety data sheets (MSDSs) in making the diagnosis of ICD. To characterize irritant exposures leading to the diagnosis of occupational ICD (OICD), and to evaluate the occurrence of concomitant exposures to contact allergens. We included 316 patients with suspected occupational hand dermatitis, referred to the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte, Denmark during January 2010-August 2011, in a programme consisting of a clinical examination, exposure assessment, and extensive patch/prick testing. OCD was diagnosed in 228 patients. Of these patients, 118 were diagnosed with OICD. The main irritant exposures identified were wet work (n = 64), gloves (n = 45), mechanical traumas (n = 19), and oils (n = 15). Exposure to specific irritant chemicals was found in 9 patients, and was identified from MSDSs/ingredients labelling in 8 of these patients. Review of MSDSs and ingredients labelling showed that 41 patients were exposed to 41 moderate to potent contact allergens, and 18 patients were exposed to 25 weak workplace contact allergens. In the present study, the systematic exposure assessment did not reveal any new irritants. MSDSs have a limited role in the investigation of ICD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Regional distribution of ventilation in patients with obstructive sleep apnea: the role of thoracic electrical impedance tomography (EIT) monitoring.

    Science.gov (United States)

    Bongiovanni, Filippo; Mura, Benedetta; Tagliaferri, Chiara; Bisanti, Alessandra; Testani, Elisa; Maviglia, Riccardo; Della Marca, Giacomo

    2016-12-01

    The aim of our study was to apply the electrical impedance tomography (EIT) technique to the study of ventilation during wake and NREM and REM sleep in patients with obstructive sleep apneas (OSA). This is a prospective, observational, monocentric, pilot study in a neurology department with a sleep disorder center. Inclusion criteria were age ≥18 years, both gender, and diagnosis of OSA. Exclusion criteria were the contraindications to the thoracic EIT. All patients underwent laboratory-based polysomnography (PSG) alongside thoracic EIT. Primary endpoint was to compare the global impedance (GI) among the conditions: "Wake" vs "Sleep," "NREM" vs "REM," and "OSA" vs "Non-OSA." Secondary endpoint was to measure the regional distribution of impedance in the four regions of interest (ROIs), in each condition. Of the 17 consecutive patients enrolled, two were excluded because of poor-quality EIT tracings. Fifteen were analyzed, 10 men and 5 women, mean age 51.6 ± 14.4 years. GI was higher in Wake vs Sleep (Wake 13.24 ± 11.23; Sleep 12.56 ± 13.36; p EIT can prove a valuable additional strategy for the evaluation of OSA patients.

  8. H(alpha) Proxies for EIT Crinkles: Further Evidence for Preflare "Breakout"-Type Activity in an Ejective Solar Eruption

    Science.gov (United States)

    Sterling, Alphonse C.; Qiu, Jiong; Wang, Haimin; Moore, Ronald L.

    2001-01-01

    We present H(alpha) observations from Big Bear Solar Observatory of an eruptive flare in NOAA Active Region 8210, occurring near 22:30 UT on 1998 May 1. Previously, using the Extreme Ultraviolet Imaging Telescope (EIT) on the Solar and Heliospheric Observatory (SOHO) spacecraft, we found that a pattern of transient, localized brightenings, which we call 'EIT crinkles,' appears in the neighborhood of the eruption near the time of flare onset. These EIT crinkles occur at a location in the active region well separated from the sheared core magnetic fields, which is where the most intense features of the eruption are concentrated. We also previously found that high-cadence images from the Soft X-ray Telescope (SXT) on Yohkoh indicate that soft X-ray intensity enhancements in the core begin after the start of the EIT crinkles. With the H(alpha) data, we find remote flare brightening counterparts to the EIT crinkles. Light curves as functions of time of various areas of the active region show that several of the remote flare brightenings undergo intensity increases prior to the onset of principal brightenings in the core region, consistent with our earlier findings from EIT and SXT data. These timing relationships are consistent with the eruption onset mechanism known as the breakout model, introduced by Antiochos and colleagues, which proposes that eruptions begin with reconnection at a magnetic null high above the core region. Our observations are also consistent with other proposed mechanisms that do not involve early reconnection in the core region. As a corollary, our observations are not consistent with the so-called tether-cutting models, which say that the eruption begins with reconnection in the core. The H(alpha) data further show that a filament in the core region becomes activated near the time of EIT crinkle onset, but little if any of the filament actually erupts, despite the presence of a halo coronal mass ejection (CME) associated with this event.

  9. [Gallbladder contractility in children with functional abdominal pain or irritable bowel syndrome].

    Science.gov (United States)

    Iwańczak, Franciszek; Siedlecka-Dawidko, Jolanta; Iwanczak, Barbara

    2013-07-01

    III Rome Criteria of functional gastrointestinal disorders in children, distinguished the disturbances with abdominal pain, to which irritable bowel syndrome, functional abdominal pains, functional dyspepsia and abdominal migraine were included. THE AIM OF THE STUDY was sonographic assessment of the gallbladder and its contractility in functional abdominal pain and irritable bowel syndrome in children. The study comprised 96 children aged 6 to 18 years, 59 girls and 37 boys. Depending on diagnosis, the children were divided into three groups. 38 children with functional abdominal pain constituted the first group, 26 children with irritable bowel syndrome were included to the second group, the third group consisted of 32 healthy children (control group). Diagnosis of functional abdominal pain and irritable bowel syndrome was made based on the III Rome Criteria. In irritable bowel syndrome both forms with diarrhea (13) and with constipation (13) were observed. Anatomy and contractility of the gallbladder were assessed by ultrasound examination. The presence of septum, wall thickness, thick bile, vesicle volume in fasting state and 30th and 60th minute after test meal were taken into consideration. Test meal comprised about 15% of caloric requirement of moderate metabolism. Children with bile stones and organic diseases were excluded from the study. Thickened vesicle wall and thick bile were present more frequently in children with irritable bowel syndrome and functional abdominal pain than in control group (p functional abdominal pain than in irritable bowel syndrome and control group (p = 0.003, p = 0.05). Vesicle contractility after test meal was greatest in children with functional abdominal pain. Evaluation of diminished (smaller than 30%) and enlarged (greater then 80%) gallbladder contractility at 30th and 60th minute after test meal demonstrated disturbances of contractility in children with irritable bowel syndrome and functional abdominal pain. In children

  10. Minimizing EIT image artefacts from mesh variability in finite element models.

    Science.gov (United States)

    Adler, Andy; Lionheart, William R B

    2011-07-01

    Electrical impedance tomography (EIT) solves an inverse problem to estimate the conductivity distribution within a body from electrical simulation and measurements at the body surface, where the inverse problem is based on a solution of Laplace's equation in the body. Most commonly, a finite element model (FEM) is used, largely because of its ability to describe irregular body shapes. In this paper, we show that simulated variations in the positions of internal nodes within a FEM can result in serious image artefacts in the reconstructed images. Such variations occur when designing FEM meshes to conform to conductivity targets, but the effects may also be seen in other applications of absolute and difference EIT. We explore the hypothesis that these artefacts result from changes in the projection of the anisotropic conductivity tensor onto the FEM system matrix, which introduces anisotropic components into the simulated voltages, which cannot be reconstructed onto an isotropic image, and appear as artefacts. The magnitude of the anisotropic effect is analysed for a small regular FEM, and shown to be proportional to the relative node movement as a fraction of element size. In order to address this problem, we show that it is possible to incorporate a FEM node movement component into the formulation of the inverse problem. These results suggest that it is important to consider artefacts due to FEM mesh geometry in EIT image reconstruction.

  11. A fast time-difference inverse solver for 3D EIT with application to lung imaging.

    Science.gov (United States)

    Javaherian, Ashkan; Soleimani, Manuchehr; Moeller, Knut

    2016-08-01

    A class of sparse optimization techniques that require solely matrix-vector products, rather than an explicit access to the forward matrix and its transpose, has been paid much attention in the recent decade for dealing with large-scale inverse problems. This study tailors application of the so-called Gradient Projection for Sparse Reconstruction (GPSR) to large-scale time-difference three-dimensional electrical impedance tomography (3D EIT). 3D EIT typically suffers from the need for a large number of voxels to cover the whole domain, so its application to real-time imaging, for example monitoring of lung function, remains scarce since the large number of degrees of freedom of the problem extremely increases storage space and reconstruction time. This study shows the great potential of the GPSR for large-size time-difference 3D EIT. Further studies are needed to improve its accuracy for imaging small-size anomalies.

  12. The EIT-based global inhomogeneity index is highly correlated with regional lung opening in patients with acute respiratory distress syndrome.

    Science.gov (United States)

    Zhao, Zhanqi; Pulletz, Sven; Frerichs, Inéz; Müller-Lisse, Ullrich; Möller, Knut

    2014-02-06

    The electrical impedance tomography (EIT)-based global inhomogeneity (GI) index was introduced to quantify tidal volume distribution within the lung. Up to now, the GI index was evaluated for plausibility but the analysis of how it is influenced by various physiological factors is still missing. The aim of our study was to evaluate the influence of proportion of open lung regions measured by EIT on the GI index. A constant low-flow inflation maneuver was performed in 18 acute respiratory distress syndrome (ARDS) patients (58 ± 14 years, mean age ± SD) and 8 lung-healthy patients (41 ± 12 years) under controlled mechanical ventilation. EIT raw data were acquired at 25 scans/s and reconstructed offline. Recruited lung regions were identified as those image pixels of the lung regions within the EIT scans where local impedance amplitudes exceeded 10% of the maximum amplitude during the maneuver. A series of GI indices was calculated during mechanical lung inflation, based on the differential images obtained between different time points. Respiratory system elastance (Ers) values were calculated at 10 lung volume levels during low-flow maneuver. The GI index decreased during low-flow inflation, while the percentage of open lung regions increased. The values correlated highly in both ARDS (r2 = 0.88 ± 0.08, p EIT. The GI index may prove to be a useful EIT-based index to guide ventilation therapy.

  13. Conversion between EIT and Fano spectra in a microring-Bragg grating coupled-resonator system

    Science.gov (United States)

    Zhang, Zecen; Ng, Geok Ing; Hu, Ting; Qiu, Haodong; Guo, Xin; Wang, Wanjun; Rouifed, Mohamed Saïd; Liu, Chongyang; Wang, Hong

    2017-08-01

    A conversion between the electromagnetically induced transparency (EIT) transmission and Fano transmission is theoretically and experimentally demonstrated in an all-pass microring-Bragg grating (APMR-BG) coupled-resonator system. In this work, the coupling between the two resonators (the microring resonator and the Fabry-Perot resonator formed by two Bragg gratings) gives rise to the EIT and Fano transmissions. The resonant status strongly depends on the round-trip attenuation of the microring and the coupling strength. By tuning the coupling strength, the EIT and Fano transmissions can be controlled and converted. The device performance has been theoretically calculated and analyzed with a specially developed numerical model based on the transfer matrix method. The APMR-BG coupled-resonator systems with different gap widths were designed, fabricated, and characterized on a silicon-on-insulator (SOI) platform. The conversion of resonance was experimentally observed and verified. In addition, this on-chip system has the advantage of a small footprint, and the fabrication process is compatible with the planar waveguide fabrication process.

  14. Review of Irritable Bowel Syndrome Treatment

    Directory of Open Access Journals (Sweden)

    Ghadir M.R.

    2010-06-01

    Full Text Available Background and Objectives: Irritable bowel syndrome is one of the most common functional gastrointestinal disorders striking 10-20% of the world population. Although most patients do not take medical assistance, this disease enforces significant cost on the patient and health systems and has negative effects on quality of life of the individual. After diagnosis ,treatment of this disease is the next step. Many pathways of treatment has been introduced and the efficacy of each other has been established in one way or another. The first step in the path of treatment is education and confidence of patients that might also be the most important step. Fiber diet, probiotic, anti-cholinergic and anti antispasmodics, laxatives, anti-diarrhea, the drugs affecting serotonin receptors, antidepressants and anti-anxiety, the chloride channel activator and non-drug methods such as cognitive-behavior therapy, hypnotherapy, acupuncture and herbal medicine each of which has been tested on irritable bowel syndrome and efficacy of each one has been indicated in one way or another. This paper tried to outline new treatments available in addition to categorization and discussion of various treatments for irritable bowel syndrome.Keywords: Irritable Bowel Syndrome; Probiotics; Parasmpatholytics; Laxatives.

  15. H-alpha Proxies for EIT Crinkles: Further Evidence for Pre-Flare "Breakout"-Type Activity in an Ejective Solar Eruption

    Science.gov (United States)

    Sterling, Alphonse C.; Moore, R. L.; Qiu, J.; Wang, H.; Whitaker, Ann F. (Technical Monitor)

    2001-01-01

    We present Halpha observations from Big Bear Solar Observatory of an eruptive flare in NOAA AR 8210, occurring near 22:30 UT on 1998 May 1. Previously, using the EUV Imaging Telescope (EIT) on the SOHO spacecraft, we found that a pattern of transient, localized brightenings, which we call "EIT crinkles," appears in the neighborhood of the eruption near the time of flare onset. These EIT crinkles occur at a location in the active region well separated from the sheared core magnetic fields, which is where the most intense features of the eruption are concentrated. We also previously found that high-cadence images from the Soft X-ray Telescope (SXT) on Yohkoh indicate that soft X-ray intensity enhancements in the core begin after the start of the EIT crinkles. With the Halpha data, we find remote flare brightening counterparts to the EIT crinkles. Lightcurves as functions of time of various areas of the active region show that several of the remote flare brightenings undergo intensity increases prior to onset of principle brightenings in the core region, consistent with our earlier findings from EIT and SXT data. These timing relationships are consistent with the eruption onset mechanism known as the breakout model, introduced by Antiochos and colleagues, which proposes that eruptions begin with reconnection at a magnetic null high above the core region. Our observations are also consistent with other proposed mechanisms which do not involve early reconnection in the core region. As a corollary, our observations are not consistent with the so-called tether cutting models, which say that the eruption begins with reconnection in the core. The Halpha data further show that a filament in the core region becomes activated near the time of EIT crinkle onset, but little if any of the filament actually erupts, despite the presence of a halo Coronal Mass Ejection (CME) associated with this event.

  16. Eye irritancy screening for classification of chemicals.

    Science.gov (United States)

    van Erp, Y H; Weterings, P J

    1990-01-01

    A screening method was applied to determine the eye irritation potential of industrial chemicals. Bovine eyes (BE) were used to predict corneal damage and chicken egg chorioallantoic membranes (CAM) to estimate the irritancy potential of chemical substances towards the conjunctivae. Exposure of the BE to a test substance is followed by grading of the corneal opacity and epithelial injury. The CAM is inspected for signs of capillary injection, haemorrhages and coagulation. The tests are collectively called the BECAM assay. So far, almost 150 substances have been evaluated in this test system. A good correlation was observed between the BECAM assay and in vivo data; less than 5% of chemicals showed a clear disagreement. Also the assay is promising for labelling requirements according to the EEC criteria.

  17. Level-set-based reconstruction algorithm for EIT lung images: first clinical results.

    Science.gov (United States)

    Rahmati, Peyman; Soleimani, Manuchehr; Pulletz, Sven; Frerichs, Inéz; Adler, Andy

    2012-05-01

    We show the first clinical results using the level-set-based reconstruction algorithm for electrical impedance tomography (EIT) data. The level-set-based reconstruction method (LSRM) allows the reconstruction of non-smooth interfaces between image regions, which are typically smoothed by traditional voxel-based reconstruction methods (VBRMs). We develop a time difference formulation of the LSRM for 2D images. The proposed reconstruction method is applied to reconstruct clinical EIT data of a slow flow inflation pressure-volume manoeuvre in lung-healthy and adult lung-injury patients. Images from the LSRM and the VBRM are compared. The results show comparable reconstructed images, but with an improved ability to reconstruct sharp conductivity changes in the distribution of lung ventilation using the LSRM.

  18. Level-set-based reconstruction algorithm for EIT lung images: first clinical results

    International Nuclear Information System (INIS)

    Rahmati, Peyman; Adler, Andy; Soleimani, Manuchehr; Pulletz, Sven; Frerichs, Inéz

    2012-01-01

    We show the first clinical results using the level-set-based reconstruction algorithm for electrical impedance tomography (EIT) data. The level-set-based reconstruction method (LSRM) allows the reconstruction of non-smooth interfaces between image regions, which are typically smoothed by traditional voxel-based reconstruction methods (VBRMs). We develop a time difference formulation of the LSRM for 2D images. The proposed reconstruction method is applied to reconstruct clinical EIT data of a slow flow inflation pressure–volume manoeuvre in lung-healthy and adult lung-injury patients. Images from the LSRM and the VBRM are compared. The results show comparable reconstructed images, but with an improved ability to reconstruct sharp conductivity changes in the distribution of lung ventilation using the LSRM. (paper)

  19. A retrospective analysis of in vivo eye irritation, skin irritation and skin sensitisation studies with agrochemical formulations: Setting the scene for development of alternative strategies.

    Science.gov (United States)

    Corvaro, M; Gehen, S; Andrews, K; Chatfield, R; Macleod, F; Mehta, J

    2017-10-01

    Analysis of the prevalence of health effects in large scale databases is key in defining testing strategies within the context of Integrated Approaches on Testing and Assessment (IATA), and is relevant to drive policy changes in existing regulatory toxicology frameworks towards non-animal approaches. A retrospective analysis of existing results from in vivo skin irritation, eye irritation, and skin sensitisation studies on a database of 223 agrochemical formulations is herein published. For skin or eye effects, high prevalence of mild to non-irritant formulations (i.e. per GHS, CLP or EPA classification) would generally suggest a bottom-up approach. Severity of erythema or corneal opacity, for skinor eye effects respectively, were the key drivers for classification, consistent with existing literature. The reciprocal predictivity of skin versus eye irritation and the good negative predictivity of the GHS additivity calculation approach (>85%) provided valuable non-testing evidence for irritation endpoints. For dermal sensitisation, concordance on data from three different methods confirmed the high false negative rate for the Buehler method in this product class. These results have been reviewed together with existing literature on the use of in vitro alternatives for agrochemical formulations, to propose improvements to current regulatory strategies and to identify further research needs. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Evaluation of Ocular Irritation and Bioavailability of Voriconazole Loaded Microemulsion.

    Science.gov (United States)

    Kumar, Rakesh; Sinha, Vivek Ranjan

    2017-01-01

    Voriconazole (VCZ), a second-generation antifungal with excellent attributes like, broad-spectrum activity, targeted delivery, and tolerability. VCZ loaded microemulsion could be an effective strategy for efficient ocular delivery of the drug. To perform corneal irritation studies and in vivo delivery of VCZ microemulsion to establish its potential as an efficient ocular delivery system. Ocular irritancy was performed by HETCAM (Hen's Egg Test Chorio Allantoic Membrane) assay, corneal histopathology and Draize test. Ex vivo and in vivo studies were performed to determine permeation efficiency of VCZ microemulsion. The irritation studies suggested the non-irritant nature of the microemulsion. The ex vivo studies performed on excised cornea displayed significant enhancement in drug permeation/penetration from microemulsion in contrast to the drug suspension. Further, the in vivo study confirmed the higher availability of VCZ (from microemulsion) in aqueous humor with minimal nasolacrimal drainage (lower plasma drug content) when compared with the drug suspension. The non-irritant nature and high corneal permeation of VCZ encourages the role of microemulsion as a potential ocular delivery system. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. PLASMA DIAGNOSTICS OF AN EIT WAVE OBSERVED BY HINODE/EIS AND SDO/AIA

    Energy Technology Data Exchange (ETDEWEB)

    Veronig, A. M.; Kienreich, I. W.; Muhr, N.; Temmer, M. [Institute of Physics, University of Graz, Universitaetsplatz 5, A-8010 Graz (Austria); Goemoery, P. [Astronomical Institute, Slovak Academy of Sciences, SK-05960 Tatranska Lomnica (Slovakia); Vrsnak, B. [Hvar Observatory, Faculty of Geodesy, Kaciceva 26, 1000 Zagreb (Croatia); Warren, H. P., E-mail: astrid.veronig@uni-graz.at [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2011-12-10

    We present plasma diagnostics of an Extreme-Ultraviolet Imaging Telescope (EIT) wave observed with high cadence in Hinode/Extreme-Ultraviolet Imaging Spectrometer (EIS) sit-and-stare spectroscopy and Solar Dynamics Observatory/Atmospheric Imaging Assembly imagery obtained during the HOP-180 observing campaign on 2011 February 16. At the propagating EIT wave front, we observe downward plasma flows in the EIS Fe XII, Fe XIII, and Fe XVI spectral lines (log T Almost-Equal-To 6.1-6.4) with line-of-sight (LOS) velocities up to 20 km s{sup -1}. These redshifts are followed by blueshifts with upward velocities up to -5 km s{sup -1} indicating relaxation of the plasma behind the wave front. During the wave evolution, the downward velocity pulse steepens from a few km s{sup -1} up to 20 km s{sup -1} and subsequently decays, correlated with the relative changes of the line intensities. The expected increase of the plasma densities at the EIT wave front estimated from the observed intensity increase lies within the noise level of our density diagnostics from EIS Fe XIII 202/203 A line ratios. No significant LOS plasma motions are observed in the He II line, suggesting that the wave pulse was not strong enough to perturb the underlying chromosphere. This is consistent with the finding that no H{alpha} Moreton wave was associated with the event. The EIT wave propagating along the EIS slit reveals a strong deceleration of a Almost-Equal-To -540 m s{sup -2} and a start velocity of v{sub 0} Almost-Equal-To 590 km s{sup -1}. These findings are consistent with the passage of a coronal fast-mode MHD wave, pushing the plasma downward and compressing it at the coronal base.

  2. Irritable Bowel Syndrome

    Science.gov (United States)

    ... your belly area), constipation (when you can't poop), and diarrhea (when you poop too much). If you have irritable bowel syndrome, ... food particles are also known as stool, a bowel movement, or poop. Here's why an intestine gets "irritable." ...

  3. Differentiating allergic and irritant contact dermatitis by high-definition optical coherence tomography

    DEFF Research Database (Denmark)

    Boone, Marc A L M; Jemec, Gregor B E; Del Marmol, V

    2015-01-01

    Differentiation of allergic contact dermatitis (ACD) and irritant contact dermatitis (ICD) is important because of different management requirements. Various non-invasive tests have been used in an attempt to improve diagnosis. In irritant dermatitis, thickening of the epidermis has been a constant...... was threefold. (1) To evaluate the correlation between HD-OCT features and clinical scores of allergic and irritant patch test reactions. (2) To explore the potential of HD-OCT in optimizing the visual patch test scoring. (3) To assess in vivo the cytological and 3-D micro-architectural differences in skin...... reaction types between doubtful positive ACD and ICD. Twenty-two volunteers were patch tested using potassium(VI)dichromate, cobalt(II)chloride, nickel(II) sulfate and palladium(II)chloride. Visual patch test scoring and HD-OCT assisted patch test scoring were performed at 48 and 96 h after patch test...

  4. Electrical Impedance Spectroscopic Studies on Broiler Chicken Tissue Suitable for the Development of Practical Phantoms in Multifrequency EIT

    Directory of Open Access Journals (Sweden)

    Tushar Kanti Bera

    2011-06-01

    Full Text Available Phantoms are essential for assessing the system performance in Electrical Impedance Tomography (EIT. Saline phantoms with insulator inhomogeneity fail to mimic the physiological structure of real body tissue in several aspects. Saline or any other salt solutions are purely resistive and hence studying multifrequency EIT systems cannot be assessed with saline phantoms because the response of the purely resistive materials do not change over frequency. Animal tissues show a variable response over a wide band of signal frequency due to their complex physiological and physiochemical structures and hence they can suitably be used as bathing medium and inhomogeneity in the phantoms of multifrequency EIT system. An efficient assessment of a multifrequency EIT system with real tissue phantom needs a prior knowledge of the impedance profile of the bathing medium as well as the inhomogeneity. In this direction Electrical Impedance Spectroscopy (EIS of broiler chicken muscle tissue paste and broiler chicken fat tissue is conducted from 10 Hz to 2 MHz using an impedance analyzer and their impedance profiles are thoroughly studied. Results show that the broiler chicken muscle tissue paste is less resistive than the fat tissue and hence it can be successfully used as the bathing medium of the phantoms for resistivity imaging in multifrequency EIT. Fat tissue is found more resistive than the muscle tissue which makes it more suitable for the inhomogeneity in phantoms of resistivity imaging study. doi:10.5617/jeb.174 J Electr Bioimp, vol. 2, pp. 48-63, 2011

  5. The Three-Dimensional EIT Wave

    Science.gov (United States)

    Thompson, B. J.; Biesecker, D. A.; Gilbert, H. R.; Lawrence, G. R.; Ofman, L.; Wu, S. T.; Warmuth, A.; Fisher, Richard R. (Technical Monitor)

    2002-01-01

    An EIT wave is an impulsive disturbance which has been observed in the EUV, Soft X-ray and white light corona, with corresponding observations in the chromosphere. The effects of these disturbances can be observed across the entire solar disk of the Sun, and throughout the inner heliosphere as well. However, the picture is not complete; observations alone do not establish a complete understanding of the nature of this three-dimensional phenomenon. A number of associated phenomena have been documented, though in most cases causality has not determined. Additionally, it is unclear which factors govern the impulse's ability to affect regions of the corona and heliosphere. We discuss the various observations and the models which provided links between the associated phenomena.

  6. Molecular restrictions for human eye irritation by chemical vapors

    International Nuclear Information System (INIS)

    Cometto-Muniz, J. Enrique; Cain, William S.; Abraham, Michael H.

    2005-01-01

    Previous research showed a cut-off along homologous volatile organic compounds (VOCs) in their ability to produce acute human mucosal irritation. The present study sought to specify the particular cut-off homolog for sensory eye irritation in an acetate and n-alcohol series. A 1900-ml glass vessel system and a three-alternative forced-choice procedure served to test nonyl, decyl, and dodecyl acetate, and 1-nonanol, 1-decanol, and 1-undecanol. Flowrate to the eye ranged from 2 to 8 L/min and time of exposure from 3 to 24 s. Decyl acetate and 1-undecanol were the shortest homologs that failed to produce eye irritation under all conditions, producing a cut-off effect. Increasing the vapor concentration of decyl acetate and 1-undecanol by 3 and 8 times, respectively, via heating them to 37 deg C made either or both VOCs detectable to only half of the 12 subjects tested, even though the higher vapor concentration was well above a predicted eye irritation threshold. When eye irritation thresholds for homologous acetates and n-alcohols were plotted as a function of the longest unfolded length of the molecule, the values for decyl acetate and 1-undecanol fell within a restricted range of 18 to 19 A. The outcome suggests that the basis for the cut-off is biological, that is, the molecule lacks a key size or structure to trigger transduction, rather than physical, that is, the vapor concentration is too low to precipitate detection

  7. Significance of hair-dye base-induced sensory irritation.

    Science.gov (United States)

    Fujita, F; Azuma, T; Tajiri, M; Okamoto, H; Sano, M; Tominaga, M

    2010-06-01

    Oxidation hair-dyes, which are the principal hair-dyes, sometimes induce painful sensory irritation of the scalp caused by the combination of highly reactive substances, such as hydrogen peroxide and alkali agents. Although many cases of severe facial and scalp dermatitis have been reported following the use of hair-dyes, sensory irritation caused by contact of the hair-dye with the skin has not been reported clearly. In this study, we used a self-assessment questionnaire to measure the sensory irritation in various regions of the body caused by two model hair-dye bases that contained different amounts of alkali agents without dyes. Moreover, the occipital region was found as an alternative region of the scalp to test for sensory irritation of the hair-dye bases. We used this region to evaluate the relationship of sensitivity with skin properties, such as trans-epidermal water loss (TEWL), stratum corneum water content, sebum amount, surface temperature, current perception threshold (CPT), catalase activities in tape-stripped skin and sensory irritation score with the model hair-dye bases. The hair-dye sensitive group showed higher TEWL, a lower sebum amount, a lower surface temperature and higher catalase activity than the insensitive group, and was similar to that of damaged skin. These results suggest that sensory irritation caused by hair-dye could occur easily on the damaged dry scalp, as that caused by skin cosmetics reported previously.

  8. Occupational irritant contact dermatitis due to petroleum naphtha

    Directory of Open Access Journals (Sweden)

    Aslı Aytekin

    2014-12-01

    Full Text Available Irritant contact dermatitis (ICD is responsible for the vast majority of occupational contact dermatitis and usually seen in professional groups working with wet hand. However, today, with the increasing business lines, employees are exposed to a variety of irritants. Occupational exposure to many chemicals and toxic irritants affect not only the skin, but also the other systems. Therefore, this situation resulting with loss of work and changes in business may become a public health problem. The diagnosis of occupational contact dermatitis should not be limited only with tests for allergens, detailed history of exposure to workplace substances and careful examination of product safety forms are necessary. In addition, by establishing close relationship between occupational physicians and employers, preventive measures should be taken before similar diseases occur in other workers in the same work place. In order to highlight this issue, a 32-year-old male patient working in an invitation card fabric is presented in this case report. Irritant contact dermatitis secondary to “petroleum naphta” was present in the patient’s arms. Another important feature of this case, as far as we know, this is the first case of irritant contact dermatitis due to naphtha in the literature.

  9. A human hemi-cornea model for eye irritation testing: quality control of production, reliability and predictive capacity.

    Science.gov (United States)

    Engelke, M; Zorn-Kruppa, M; Gabel, D; Reisinger, K; Rusche, B; Mewes, K R

    2013-02-01

    We have developed a 3-dimensional human hemi-cornea which comprises an immortalized epithelial cell line and keratocytes embedded in a collagen stroma. In the present study, we have used MTT reduction of the whole tissue to clarify whether the production of this complex 3-D-model is transferable into other laboratories and whether these tissues can be constructed reproducibly. Our results demonstrate the reproducible production of the hemi-cornea model according to standard operation procedures using 15 independent batches of reconstructed hemi-cornea models in two independent laboratories each. Furthermore, the hemi-cornea tissues have been treated with 20 chemicals of different eye-irritating potential under blind conditions to assess the performance and limitations of our test system comparing three different prediction models. The most suitable prediction model revealed an overall in vitro-in vivo concordance of 80% and 70% in the participating laboratories, respectively, and an inter-laboratory concordance of 80%. Sensitivity of the test was 77% and specificity was between 57% and 86% to discriminate classified from non-classified chemicals. We conclude that additional physiologically relevant endpoints in both epithelium and stroma have to be developed for the reliable prediction of all GHS classes of eye irritation in one stand alone test system. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Surfactant-induced skin irritation and skin repair: evaluation of a cumulative human irritation model by noninvasive techniques.

    Science.gov (United States)

    Wilhelm, K P; Freitag, G; Wolff, H H

    1994-12-01

    Although surfactant-induced acute irritant dermatitis has been extensively studied, our understanding about the induction and repair of the clinically more relevant chronic form is limited. Our purpose was to investigate qualitative and quantitative differences in surfactant-induced irritant skin reactions from cumulative exposure to structurally unrelated surfactants and to compare the maximal irritant responses from this model with corresponding reactions noted in a previously reported acute irritation model. Sodium lauryl sulfate (SLS), dodecyl trimethyl ammonium bromide (DTAB), and potassium soap were the model irritants. Surfactant solutions (7.5%) were applied for 20 minutes daily (for 8 consecutive days excluding the weekend) to the volar aspect of the forearm of 11 volunteers. Irritant reactions were repeatedly assessed until complete healing was indicated by visual assessment and by measurements of transepidermal water loss (TEWL), erythema (skin color reflectance), and stratum corneum hydration (electrical capacitance). Maximum irritant responses were compared with corresponding reactions from an acute irritation model. TEWL was increased by SLS and DTAB to the same extent, but erythema was significantly higher in DTAB-treated skin. Skin dryness, as demonstrated by decreased capacitance values and increased scores for scaling and fissuring, was significantly more pronounced than in an acute irritation model for SLS and DTAB, although no difference was detected between the two surfactants. Potassium soap led to a slight increase in TEWL, whereas the remaining features were not significantly changed. This chronic irritation model appears to represent the clinical situation of irritant contact dermatitis with pronounced skin dryness more closely than the acute irritation model. The present study confirms that an extended time is needed for complete healing of irritant skin reactions. We also demonstrated that the evaluation of the irritation potential of

  11. Higher order total variation regularization for EIT reconstruction.

    Science.gov (United States)

    Gong, Bo; Schullcke, Benjamin; Krueger-Ziolek, Sabine; Zhang, Fan; Mueller-Lisse, Ullrich; Moeller, Knut

    2018-01-08

    Electrical impedance tomography (EIT) attempts to reveal the conductivity distribution of a domain based on the electrical boundary condition. This is an ill-posed inverse problem; its solution is very unstable. Total variation (TV) regularization is one of the techniques commonly employed to stabilize reconstructions. However, it is well known that TV regularization induces staircase effects, which are not realistic in clinical applications. To reduce such artifacts, modified TV regularization terms considering a higher order differential operator were developed in several previous studies. One of them is called total generalized variation (TGV) regularization. TGV regularization has been successively applied in image processing in a regular grid context. In this study, we adapted TGV regularization to the finite element model (FEM) framework for EIT reconstruction. Reconstructions using simulation and clinical data were performed. First results indicate that, in comparison to TV regularization, TGV regularization promotes more realistic images. Graphical abstract Reconstructed conductivity changes located on selected vertical lines. For each of the reconstructed images as well as the ground truth image, conductivity changes located along the selected left and right vertical lines are plotted. In these plots, the notation GT in the legend stands for ground truth, TV stands for total variation method, and TGV stands for total generalized variation method. Reconstructed conductivity distributions from the GREIT algorithm are also demonstrated.

  12. Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCE(TM).

    Science.gov (United States)

    Jang, Won-Hee; Jung, Kyoung-Mi; Yang, Hye-Ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min

    2015-07-01

    The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCE(TM) which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCE(TM) can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines.

  13. Monitoring lung contusion in a porcine polytrauma model using EIT: an application study.

    Science.gov (United States)

    Santos, Susana Aguiar; Wembers, Carlos Castelar; Horst, Klemens; Pfeifer, Roman; Simon, Tim-Philipp; Pape, Hans-Christoph; Hildebrand, Frank; Czaplik, Michael; Leonhardt, Steffen; Teichmann, Daniel

    2017-07-26

    Lung contusion is the most common lung injury following blunt chest trauma which, in turn, is associated with high mortality rates (Gavelli et al 2002 Eur. Radiol. 12 1273-94). Lung contusion is characterized by hemorrhage and edema with consecutively reduced compliance. Objective and Approach: In this study, unilateral lung contusion and other traumata were induced in 12 pigs by using a bolt gun machine. To investigate the pathophysiological consequences of lung contusion, information on clinical parameters was collected and monitored regularly while animals were additionally monitored with electrical impedance tomography (EIT) before trauma, and at 4, 24, 48 and 72 h after polytrauma. Statistical analyses showed significant differences between the measurement time points in terms of lung compliance ([Formula: see text]) and in global EIT parameters, such as absolute global impedance (aGlobImp) ([Formula: see text]), tidal impedance variation (TIV) ([Formula: see text]) and the center of ventilation (CoV) ([Formula: see text]). Additionally, distinct analyses for the left (non-injured) and right (injured) lung were also performed. In this context, during the progress of lung contusion, significant changes were found for the injured lung in TIV ([Formula: see text]), global inhomogeneity ([Formula: see text]), regional ventilation delay ([Formula: see text]), CoV ([Formula: see text]) and in regions of non-ventilation (rNoVent) ([Formula: see text]). Furthermore, TIV and rNoVent were capable to differentiate the injured and the contralateral healthy lung at 4 and 24 h after injury (TIV: [Formula: see text] and [Formula: see text]; rNoVent: [Formula: see text] and [Formula: see text]). TIV reached a sensitivity of 82% (specificity of 100%) at 4 h and sensitivity of 82% (specificity of 82%) at 24 h after injury, in detecting lung contusion specific consequences. The results indicate that EIT might be a valuable tool to detect and to monitor lung injuries

  14. Determination of head conductivity frequency response in vivo with optimized EIT-EEG.

    Science.gov (United States)

    Dabek, Juhani; Kalogianni, Konstantina; Rotgans, Edwin; van der Helm, Frans C T; Kwakkel, Gert; van Wegen, Erwin E H; Daffertshofer, Andreas; de Munck, Jan C

    2016-02-15

    Electroencephalography (EEG) benefits from accurate head models. Dipole source modelling errors can be reduced from over 1cm to a few millimetres by replacing generic head geometry and conductivity with tailored ones. When adequate head geometry is available, electrical impedance tomography (EIT) can be used to infer the conductivities of head tissues. In this study, the boundary element method (BEM) is applied with three-compartment (scalp, skull and brain) subject-specific head models. The optimal injection of small currents to the head with a modular EIT current injector, and voltage measurement by an EEG amplifier is first sought by simulations. The measurement with a 64-electrode EEG layout is studied with respect to three noise sources affecting EIT: background EEG, deviations from the fitting assumption of equal scalp and brain conductivities, and smooth model geometry deviations from the true head geometry. The noise source effects were investigated depending on the positioning of the injection and extraction electrode and the number of their combinations used sequentially. The deviation from equal scalp and brain conductivities produces rather deterministic errors in the three conductivities irrespective of the current injection locations. With a realistic measurement of around 2 min and around 8 distant distinct current injection pairs, the error from the other noise sources is reduced to around 10% or less in the skull conductivity. The analysis of subsequent real measurements, however, suggests that there could be subject-specific local thinnings in the skull, which could amplify the conductivity fitting errors. With proper analysis of multiplexed sinusoidal EIT current injections, the measurements on average yielded conductivities of 340 mS/m (scalp and brain) and 6.6 mS/m (skull) at 2 Hz. From 11 to 127 Hz, the conductivities increased by 1.6% (scalp and brain) and 6.7% (skull) on the average. The proper analysis was ensured by using recombination of

  15. Determination of head conductivity frequency response in vivo with optimized EIT-EEG

    NARCIS (Netherlands)

    Dabek, Juhani; Kalogianni, Konstantina; Rotgans, Edwin; van der Helm, Frans C.T.; Kwakkel, Gert; van Wegen, Erwin E.H.; Daffertshofer, Andreas; de Munck, Jan C.

    2016-01-01

    Electroencephalography (EEG) benefits from accurate head models. Dipole source modelling errors can be reduced from over 1 cm to a few millimetres by replacing generic head geometry and conductivity with tailored ones. When adequate head geometry is available, electrical impedance tomography (EIT)

  16. Síndrome de intestino irritable y diverticulosis

    OpenAIRE

    Kestenberg Himelfar, Abraham; Fundación Valle de Lili

    1998-01-01

    Síndrome de intestino irritable (SII)/ ¿Cómo funciona el sistema digestivo?/¿Qué es el síndrome de intestino irritable?/¿Cuáles son los síntomas del síndrome de intestino irritable?/¿Qué causa el síndrome de intestino irritable?/¿Qué papel juega la tensión emocional en el origen del síndrome de intestino irritable?/¿Cómo saber si el problema es síndrome de intestino irritable o si es algo diferente?/¿Cómo se debe tratar el síndrome de intestino irritable?/¿Se deben evitar algunos alimentos?/¿...

  17. Demonstration of Double EIT Using Coupled Harmonic Oscillators and RLC Circuits

    Science.gov (United States)

    Harden, Joshua; Joshi, Amitabh; Serna, Juan D.

    2011-01-01

    Single and double electromagnetically induced transparencies (EIT) in a medium, consisting of four-level atoms in the inverted-Y configuration, are discussed using mechanical and electrical analogies. A three-coupled spring-mass system subject to damping and driven by an external force is used to represent the four-level atom mechanically. The…

  18. Efficient weakly-radiative wireless energy transfer: An EIT-like approach

    International Nuclear Information System (INIS)

    Hamam, Rafif E.; Karalis, Aristeidis; Joannopoulos, J.D.; Soljacic, Marin

    2009-01-01

    Inspired by a quantum interference phenomenon known in the atomic physics community as electromagnetically induced transparency (EIT), we propose an efficient weakly radiative wireless energy transfer scheme between two identical classical resonant objects, strongly coupled to an intermediate classical resonant object of substantially different properties, but with the same resonance frequency. The transfer mechanism essentially makes use of the adiabatic evolution of an instantaneous (so called 'dark') eigenstate of the coupled 3-object system. Our analysis is based on temporal coupled mode theory (CMT), and is general enough to be valid for various possible sorts of coupling, including the resonant inductive coupling on which witricity-type wireless energy transfer is based. We show that in certain parameter regimes of interest, this scheme can be more efficient, and/or less radiative than other, more conventional approaches. A concrete example of wireless energy transfer between capacitively-loaded metallic loops is illustrated at the beginning, as a motivation for the more general case. We also explore the performance of the currently proposed EIT-like scheme, in terms of improving efficiency and reducing radiation, as the relevant parameters of the system are varied.

  19. The suitability of EIT to estimate EELV in a clinical trial compared to oxygen wash-in/wash-out technique.

    Science.gov (United States)

    Karsten, Jan; Meier, Torsten; Iblher, Peter; Schindler, Angela; Paarmann, Hauke; Heinze, Hermann

    2014-02-01

    Open endotracheal suctioning procedure (OSP) and recruitment manoeuvre (RM) are known to induce severe alterations of end-expiratory lung volume (EELV). We hypothesised that EIT lung volumes lack clinical validity. We studied the suitability of EIT to estimate EELV compared to oxygen wash-in/wash-out technique. Fifty-four postoperative cardiac surgery patients were enrolled and received standardized ventilation and OSP. Patients were randomized into two groups receiving either RM after suctioning (group RM) or no RM (group NRM). Measurements were conducted at the following time points: Baseline (T1), after suctioning (T2), after RM or NRM (T3), and 15 and 30 min after T3 (T4 and T5). We measured EELV using the oxygen wash-in/wash-out technique (EELVO2) and computed EELV from EIT (EELVEIT) by the following formula: EELVEITTx,y…=EELVO2+ΔEELI×VT/ΔZ. EELVEIT values were compared with EELVO2 using Bland-Altman analysis and Pearson correlation. Limits of agreement ranged from -0.83 to 1.31 l. Pearson correlation revealed significant results. There was no significant impact of RM or NRM on EELVO2-EELVEIT relationship (p=0.21; p=0.23). During typical routine respiratory manoeuvres like endotracheal suctioning or alveolar recruitment, EELV cannot be estimated by EIT with reasonable accuracy.

  20. Sparse regularization for EIT reconstruction incorporating structural information derived from medical imaging.

    Science.gov (United States)

    Gong, Bo; Schullcke, Benjamin; Krueger-Ziolek, Sabine; Mueller-Lisse, Ullrich; Moeller, Knut

    2016-06-01

    Electrical impedance tomography (EIT) reconstructs the conductivity distribution of a domain using electrical data on its boundary. This is an ill-posed inverse problem usually solved on a finite element mesh. For this article, a special regularization method incorporating structural information of the targeted domain is proposed and evaluated. Structural information was obtained either from computed tomography images or from preliminary EIT reconstructions by a modified k-means clustering. The proposed regularization method integrates this structural information into the reconstruction as a soft constraint preferring sparsity in group level. A first evaluation with Monte Carlo simulations indicated that the proposed solver is more robust to noise and the resulting images show fewer artifacts. This finding is supported by real data analysis. The structure based regularization has the potential to balance structural a priori information with data driven reconstruction. It is robust to noise, reduces artifacts and produces images that reflect anatomy and are thus easier to interpret for physicians.

  1. Small intestinal bacterial overgrowth as an uncommon cause of false positive lactose hydrogen breath test among patients with diarrhea-predominant irritable bowel syndrome in Asia.

    Science.gov (United States)

    Wang, Yilin; Xiong, Lishou; Gong, Xiaorong; Li, Weimin; Zhang, Xiangsong; Chen, Minhu

    2015-06-01

    It has been reported that small intestinal bacterial overgrowth (SIBO) may lead to false positive diagnoses of lactose malabsorption (LM) in irritable bowel syndrome patients. The aim of this study was to determine the influence of SIBO on lactose hydrogen breath test (HBT) results in these patients. Diarrhea-predominant irritable bowel syndrome patients with abnormal lactose HBTs ingested a test meal containing (99m) Tc and lactose. The location of the test meal and the breath levels of hydrogen were recorded simultaneously by scintigraphic scanning and lactose HBT, respectively. The increase in hydrogen concentration was not considered to be caused by SIBO if ≥ 10% of (99m) Tc accumulated in the cecal region at the time or before of abnormal lactose HBT. LM was present in 84% (31/37) of irritable bowel syndrome patients. Twenty of these patients agreed to measurement of oro-cecal transit time. Only three patients (15%) with abnormal lactose HBT might have had SIBO. The median oro-cecal transit time between LM and lactose intolerance patients were 75 min and 45 min, respectively (Z=2.545, P=0.011). Most of irritable bowel syndrome patients with an abnormal lactose HBT had LM. SIBO had little impact on the interpretation of lactose HBTs. The patients with lactose intolerance had faster small intestinal transit than LM patients. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  2. Reconstituted human corneal epithelium: a new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products.

    Science.gov (United States)

    Doucet, O; Lanvin, M; Thillou, C; Linossier, C; Pupat, C; Merlin, B; Zastrow, L

    2006-06-01

    The aim of this study was to evaluate the interest of a new three-dimensional epithelial model cultivated from human corneal cells to replace animal testing in the assessment of eye tolerance. To this end, 65 formulated cosmetic products and 36 chemicals were tested by means of this in vitro model using a simplified toxicokinetic approach. The chemicals were selected from the ECETOC data bank and the EC/HO International validation study list. Very satisfactory results were obtained in terms of concordance with the Draize test data for the formulated cosmetic products. Moreover, the response of the corneal model appeared predictive of human ocular response clinically observed by ophthalmologists. The in vitro scores for the chemicals tested strongly correlated with their respective scores in vivo. For all the compounds tested, the response of the corneal model to irritants was similar regardless of their chemical structure, suggesting a good robustness of the prediction model proposed. We concluded that this new three-dimensional epithelial model, developed from human corneal cells, could be promising for the prediction of eye irritation induced by chemicals and complex formulated products, and that these two types of materials should be tested using a similar protocol. A simple shortening of the exposure period was required for the chemicals assumed to be more aggressively irritant to the epithelial tissues than the cosmetic formulae.

  3. Review of Irritable Bowel Syndrome Treatment

    Directory of Open Access Journals (Sweden)

    M.R Ghadir

    2012-05-01

    Full Text Available

    Background and Objectives: Irritable bowel syndrome is one of the most common functional gastrointestinal disorders striking 10-20% of the world population. Although most patients do not take medical assistance, this disease enforces significant cost on the patient and health systems and has negative effects on quality of life of the individual. After diagnosis ,treatment of this disease is the next step. Many pathways of treatment has been introduced and the efficacy of each other has been established in one way or another. The first step in the path of treatment is education and confidence of patients that might also be the most important step. Fiber diet, probiotic, anti-cholinergic and anti antispasmodics, laxatives, anti-diarrhea, the drugs affecting serotonin receptors, antidepressants and anti-anxiety, the chloride channel activator and non-drug methods such as cognitive-behavior therapy, hypnotherapy, acupuncture and herbal medicine each of which has been tested on irritable bowel syndrome and efficacy of each one has been indicated in one way or another. This paper tried to outline new treatments available in addition to categorization and discussion of various treatments for irritable bowel syndrome.

  4. Direct EIT reconstructions of complex admittivities on a chest-shaped domain in 2-D.

    Science.gov (United States)

    Hamilton, Sarah J; Mueller, Jennifer L

    2013-04-01

    Electrical impedance tomography (EIT) is a medical imaging technique in which current is applied on electrodes on the surface of the body, the resulting voltage is measured, and an inverse problem is solved to recover the conductivity and/or permittivity in the interior. Images are then formed from the reconstructed conductivity and permittivity distributions. In the 2-D geometry, EIT is clinically useful for chest imaging. In this work, an implementation of a D-bar method for complex admittivities on a general 2-D domain is presented. In particular, reconstructions are computed on a chest-shaped domain for several realistic phantoms including a simulated pneumothorax, hyperinflation, and pleural effusion. The method demonstrates robustness in the presence of noise. Reconstructions from trigonometric and pairwise current injection patterns are included.

  5. Cumulative irritation potential of topical retinoid formulations.

    Science.gov (United States)

    Leyden, James J; Grossman, Rachel; Nighland, Marge

    2008-08-01

    Localized irritation can limit treatment success with topical retinoids such as tretinoin and adapalene. The factors that influence irritant reactions have been shown to include individual skin sensitivity, the particular retinoid and concentration used, and the vehicle formulation. To compare the cutaneous tolerability of tretinoin 0.04% microsphere gel (TMG) with that of adapalene 0.3% gel and a standard tretinoin 0.025% cream. The results of 2 randomized, investigator-blinded studies of 2 to 3 weeks' duration, which utilized a split-face method to compare cumulative irritation scores induced by topical retinoids in subjects with healthy skin, were combined. Study 1 compared TMG 0.04% with adapalene 0.3% gel over 2 weeks, while study 2 compared TMG 0.04% with tretinoin 0.025% cream over 3 weeks. In study 1, TMG 0.04% was associated with significantly lower cumulative scores for erythema, dryness, and burning/stinging than adapalene 0.3% gel. However, in study 2, there were no significant differences in cumulative irritation scores between TMG 0.04% and tretinoin 0.025% cream. Measurements of erythema by a chromameter showed no significant differences between the test formulations in either study. Cutaneous tolerance of TMG 0.04% on the face was superior to that of adapalene 0.3% gel and similar to that of a standard tretinoin cream containing a lower concentration of the drug (0.025%).

  6. Definition of the applicability domain of the Short Time Exposure (STE) test for predicting the eye irritation of chemicals.

    Science.gov (United States)

    Hayashi, Kazuhiko; Abo, Takayuki; Nukada, Yuko; Sakaguchi, Hitoshi

    2013-05-01

    The Short Time Exposure (STE) test is a simple and easy-to-perform in vitro eye irritation test, that uses the viability of SIRC cells (a rabbit corneal cell line) treated for five minutes as the endpoint. In this study, our goal was to define the applicability domain of the STE test, based on the results obtained with a set of 113 substances. To achieve this goal, chemicals were selected to represent both different chemical classes and different chemical properties, as well as to cover, in a balanced manner, the categories of eye irritation potential according to the Globally Harmonised System (GHS). Accuracy analysis indicated that the rates of false negatives for organic/inorganic salts (75.0%), hydrocarbons (33.3%) and alcohols (23.5%) were high. Many of the false negative results were for solid substances. It is noteworthy that no surfactant resulted in a false negative result in the STE test. Further examination of the physical property data and performance showed a significant improvement in the predictive accuracy, when substances with vapour pressures over 6kPa were excluded from the analyses. Our results indicate that several substances - i.e. certain solids such as salts, alcohols, hydrocarbons, and volatile substances with a vapour pressure over 6kPa - do not fall within the applicability domain of the STE test. Overall, we are encouraged by the performance and improved accuracy of the STE test. 2013 FRAME.

  7. Micro Coronal Bright Points Observed in the Quiet Magnetic Network by SOHO/EIT

    Science.gov (United States)

    Falconer, D. A.; Moore, R. L.; Porter, J. G.

    1997-01-01

    When one looks at SOHO/EIT Fe XII images of quiet regions, one can see the conventional coronal bright points (> 10 arcsec in diameter), but one will also notice many smaller faint enhancements in brightness (Figure 1). Do these micro coronal bright points belong to the same family as the conventional bright points? To investigate this question we compared SOHO/EIT Fe XII images with Kitt Peak magnetograms to determine whether the micro bright points are in the magnetic network and mark magnetic bipoles within the network. To identify the coronal bright points, we applied a picture frame filter to the Fe XII images; this brings out the Fe XII network and bright points (Figure 2) and allows us to study the bright points down to the resolution limit of the SOHO/EIT instrument. This picture frame filter is a square smoothing function (hlargelyalf a network cell wide) with a central square (quarter of a network cell wide) removed so that a bright point's intensity does not effect its own background. This smoothing function is applied to the full disk image. Then we divide the original image by the smoothed image to obtain our filtered image. A bright point is defined as any contiguous set of pixels (including diagonally) which have enhancements of 30% or more above the background; a micro bright point is any bright point 16 pixels or smaller in size. We then analyzed the bright points that were fully within quiet regions (0.6 x 0.6 solar radius) centered on disk center on six different days.

  8. Sensory irritation and multiple chemical sensitivity.

    Science.gov (United States)

    Anderson, R C; Anderson, J H

    1999-01-01

    Many of the symptoms described in Sick Building Syndrome (SBS) and multiple chemical sensitivity (MCS) resemble the symptoms known to be elicited by airborne irritant chemicals. Irritation of the eye, nose, and throat is common to SBS, MCS, and sensory irritation (SI). Difficulty of breathing is often seen with SBS, MCS, and pulmonary irritation (PI). We therefore asked the question: can indoor air pollutants cause SI and/or PI? In laboratory testing in which mice breathed the dilute volatile emissions of air fresheners, fabric softeners, colognes, and mattresses for 1 h, we measured various combinations of SI and PI as well as airflow decreases (analogous to asthma attacks). Air samples taken from sites associated with repeated human complaints of poor air quality also caused SI, PI, and airflow limitation (AFL) in the mice. In previous publications, we have documented numerous behavior changes in mice (which we formally studied with a functional observational battery) after exposure to product emissions or complaint site air; neurological complaints are a prominent part of SBS and MCS. All together, these data suggest that many symptoms of SBS and MCS can be described as SI, PI, AFL, and neurotoxicity. All these problems can be caused by airborne irritant chemicals such as those emitted by common commercial products and found in polluted indoor air. With some chemical mixtures (e.g., emissions of some fabric softeners, disposable diapers, and vinyl mattress covers) but not others (e.g., emissions of a solid air freshener), the SI response became larger (2- to 4-fold) when we administered a series of two or three 1-h exposures over a 24-h period. Since with each exposure the intensity of the stimulus was constant yet the magnitude of the response increased, we concluded that there was a change in the sensitivity of the mice to these chemicals. The response was not a generalized stress response because it occurred with only some mixtures of irritants and not others

  9. Existe importância na utilização de exames de fisiologia ano retal no diagnóstico da sindrome do intestino irritável? Is there importance in the use of anorectal physiologic tests in the diagnosis of the irritable bowel syndrome?

    Directory of Open Access Journals (Sweden)

    Maria Auxiliadora Prolungatti Cesar

    2009-09-01

    Full Text Available INTRODUÇÃO: Em alguns pacientes a síndrome do intestino irritável e a constipação funcional se confundem, principalmente quando o sintoma predominante na síndrome do cólon irritável é a constipação. Dentre os vários exames alguns testes fisiológicos ano retais avaliam a função esfincteriana e sensibilidade retal OBJETIVO: Verificar se existem diferenças entre as manometrias anais dos pacientes com constipação funcional e síndrome do intestino irritável. MÉTODO: Trata-se de estudo de 55 manometrias e testes de sensibilidade anais realizadas em pacientes atendidos no ambulatório de Fisiologia Anal do Serviço de Clínica Cirúrgica do Hospital Universitário de Taubaté com diagnóstico de constipação intestinal ou síndrome do intestino irritável no período de janeiro de 2006 a maio de 2007. Todos os pacientes possuíam colonoscopia a normal e foram incluídos nos critérios diagnósticos de Roma II para Constipação Funcional e Síndrome do Intestino Irritável. As manometrias foram realizadas com aparelho ALACER, de perfusão com 8 canais. RESULTADOS: Não foram encontradas diferenças entre as manometrias quanto às pressões de repouso, contração e evacuação, assim como nos valores de sensibilidade retal. Encontramos diferenças quanto à dor abdominal desencadeada nos pacientes com síndrome do intestino irritável no momento do volume máximo tolerável em que 69,2% destes pacientes apresentaram dor abdominal. CONCLUSÃO: Os pacientes com a síndrome do intestino irritável apresentam dor à distensão da ampola retal, que não ocorre nos pacientes constipados, na aferição do volume máximo tolerável, não houve diferença em relação aos outros dados da manometria.INTRODUCTION: In some patients the irritable bowel syndrome and the functional constipation is confuse, mainly when the predominant symptom in the irritable bowel syndrome is the constipation. Amongst some examinations the anal manometry

  10. All-optically tunable EIT-like dielectric metasurfaces hybridized with thin phase change material layers

    Science.gov (United States)

    Petronijevic, Emilija; Sibilia, Concita

    2017-05-01

    Electromagnetically induced transparency (EIT), a pump-induced narrow transparency window within the absorption region of a probe, had offered new perspectives in slow-light control in atomic physics. For applications in nanophotonics, the implementation on chip-scaled devices has later been obtained by mimicking this effect by metallic metamaterials. High losses in visible and near infrared range of metal-based metamaterialls have recently opened a new field of all-dielectric metamaterials; a proper configuration of high refractive index dielectric nanoresonators can mimick this effect without losses to get high Q, slow-light response. The next step would be the ability to tune their optical response, and in this work we investigate thin layers of phase change materials (PCM) for all-optical control of EIT-like all-dielectric metamaterials. PCM can be nonvolatively and reversibly switched between two stable phases that differ in optical properties by applying a visible laser pulse. The device is based on Si nanoresonators covered by a thin layer of PCM GeTe; optical and transient thermal simulations have been done to find and optimize the fabrication parameters and switching parameters such as the intensity and duration of the pulse. We have found that the EIT-like response can be switched on and off by applying the 532nm laser pulse to change the phase of the upper GeTe layer. We strongly believe that such approach could open new perspectives in all-optically controlled slow-light metamaterials.

  11. Physical characteristic and irritation index of Syzigium aromaticum essential oil in O/W and W/O creams

    Science.gov (United States)

    Safriani, R.; Sugihartini, N.; Yuliani, S.

    2017-11-01

    Essential oil of Syzigium aromaticum has been formulated in O/W and W/O creams as anti-inflammatory dosage form. The purpose of this study was to evaluate the physical characteristic and irritation index of S. aromaticum essential oil in O/W and W/O creams. The creams were made by fusion method. The creams then were evaluated the physical characteristic including pH, viscosity, spreadability and adhesivity. The irritation index was obtained by irritation skin test in male rabbit. The results showed that the W/O and O/W creams have the value of pH: 6.3 and 6.27; spreadability: 3,18 and 4.17 cm2; adhesivity: 5.59 and 0.07 minutes; viscosity: 4.43 and 2.88 Pa.S, respectively. The irritation test showed that the control enhancer caused mild irritation in both of W/O and O/W creams. These findings indicated that type of cream might influence the physical characteristic and irritation index of S. aromaticum essential oil cream.

  12. Surfactant-induced skin irritation and skin repair. Evaluation of the acute human irritation model by noninvasive techniques.

    Science.gov (United States)

    Wilhelm, K P; Freitag, G; Wolff, H H

    1994-06-01

    Although the induction of irritant dermatitis by surfactants has been extensively studied in recent years, our understanding of the repair phase of irritant dermatitis is limited. We investigated qualitative and quantitative differences in surfactant-induced irritant skin reactions from short-term exposure to three structurally different surfactants. Sodium lauryl sulfate (SLS), dodecyl trimethyl ammonium bromide (DTAB), and potassium soap were the model irritants. Surfactant solutions (0.5%) were applied for 24 hours to the volar aspect of the forearm of 11 volunteers. Irritant reactions were assessed until complete healing was indicated by visual assessment and by various aspects of skin function, that is, transepidermal water loss (TEWL), erythema (skin color reflectance), and stratum that is, transepidermal water loss (TEWL), erythema (skin color reflectance), and stratum corneum hydration (electrical capacitance). SLS and DTAB induced similar degrees of erythema, whereas SLS induced significantly higher TEWL increase. Although both erythema and TEWL were highest 1 hour after exposure to surfactants, skin dryness was a symptom with delayed onset, justifying the long observation period in this study. Minimum hydration values were measured as late as 7 days after surfactant exposure. Dryness was significantly more pronounced in areas exposed to SLS than in areas exposed to DTAB. Complete repair of the irritant reaction induced by either SLS or DTAB was achieved 17 days after surfactant exposure. Stratum corneum hydration was the last feature to return to baseline values. Potassium soap did not significantly influence any skin function. We emphasize the importance of extended periods needed before a patient with irritant contact dermatitis can be reexposed to irritant substances. The evaluation of the irritation potential of diverse surfactants depended significantly on the feature (erythema vs hydration and TEWL) measured.

  13. Irritability and Anxiety Severity Among Youth With Anxiety

    Science.gov (United States)

    Cornacchio, Danielle; Crum, Kathleen I.; Coxe, Stefany; Pincus, Donna B.; Comer, Jonathan S.

    2015-01-01

    Objective Most research on irritability and child psychopathology has focused on depressive disorders, bipolar disorder, and/or oppositional defiant disorder (ODD). Less is known about relationships between child anxiety and irritability and moderators of such associations. Method Structural equation modeling (SEM) examined associations between anxiety severity and irritability in a large sample of treatment-seeking youth with anxiety disorders (N=663, ages 7–19 years, M=12.25), after accounting for comorbid depressive disorders and ODD. Additional analyses examined whether associations were moderated by child gender, age, and generalized anxiety disorder (GAD) status. Results There was a direct link between child anxiety and irritability even after accounting for comorbid depressive disorders and ODD. Links between child anxiety and irritability were robust across child gender and age. Further, relationships between child anxiety and irritability were comparable across youth with and without GAD, suggesting that the anxiety–irritability link is relevant across child anxiety disorders and not circumscribed to youth with GAD. Conclusion Findings add to an increasing body of evidence linking child irritability to a range of internalizing and externalizing psychopathologies, and suggest that child anxiety assessment should systematically incorporate irritability evaluations. Further, youth in clinical settings displaying irritability should be assessed for the presence of anxiety. Moreover, treatments for childhood anxiety may do well to incorporate new treatment modules as needed that specifically target problems of irritability. PMID:26703910

  14. STEREO OBSERVATIONS OF FAST MAGNETOSONIC WAVES IN THE EXTENDED SOLAR CORONA ASSOCIATED WITH EIT/EUV WAVES

    International Nuclear Information System (INIS)

    Kwon, Ryun-Young; Ofman, Leon; Kramar, Maxim; Olmedo, Oscar; Davila, Joseph M.; Thompson, Barbara J.; Cho, Kyung-Suk

    2013-01-01

    We report white-light observations of a fast magnetosonic wave associated with a coronal mass ejection observed by STEREO/SECCHI/COR1 inner coronagraphs on 2011 August 4. The wave front is observed in the form of density compression passing through various coronal regions such as quiet/active corona, coronal holes, and streamers. Together with measured electron densities determined with STEREO COR1 and Extreme UltraViolet Imager (EUVI) data, we use our kinematic measurements of the wave front to calculate coronal magnetic fields and find that the measured speeds are consistent with characteristic fast magnetosonic speeds in the corona. In addition, the wave front turns out to be the upper coronal counterpart of the EIT wave observed by STEREO EUVI traveling against the solar coronal disk; moreover, stationary fronts of the EIT wave are found to be located at the footpoints of deflected streamers and boundaries of coronal holes, after the wave front in the upper solar corona passes through open magnetic field lines in the streamers. Our findings suggest that the observed EIT wave should be in fact a fast magnetosonic shock/wave traveling in the inhomogeneous solar corona, as part of the fast magnetosonic wave propagating in the extended solar corona.

  15. The role of dermal irritation in the skin tumor promoting activity of petroleum middle distillates.

    Science.gov (United States)

    Nessel, C S; Freeman, J J; Forgash, R C; McKee, R H

    1999-05-01

    Petroleum middle distillates (PMDs), a class of hydrocarbons which boil between 350-700 degrees F, are tumor promoters in mouse skin. The promotional activity is produced under conditions that also result in local changes, including chronic irritation and epidermal hyperplasia. The present study was conducted by comparing equal weekly doses of irritating and minimally or nonirritating test materials, to assess whether tumor promotion was a secondary response to these effects. Four PMDs, C10-C14 normal paraffins (NP), lightly refined paraffinic oil (LRPO), Jet Fuel A (JF), and steam-cracked gas oil (SCGO), were evaluated. Test materials were applied undiluted (2x/week) or as 28.6% (7x/week) or 50% (4x/week) concentrations in mineral oil for 52 weeks following initiation with dimethylbenzanthracene (DMBA). When applied undiluted, all materials produced moderate irritation and significant increase in tumor incidence. When NP, LRPO, or JF were applied in mineral oil diluent, skin irritation was generally ameliorated and few, if any, tumors were produced. SCGO was irritating and produced a significant increase in tumor frequency when administered in mineral-oil diluent. These data indicate that the promotional activity of straight-run PMDs is likely related to chronic irritation at the application site and not to dose. Thus, when used appropriately in the absence of prolonged irritation, these materials should not present a tumorigenic hazard to humans.

  16. Transformation of EIA to EIT by incoherent pumping of the 85Rb D1 line

    Science.gov (United States)

    Yu, Hoon; Kim, Jung Dong; Jung, Tae Young; Kim, Jung Bog

    2012-10-01

    We have observed a transformation from electromagnetically-induced absorption (EIA) to electromagnetically induced transparency (EIT) in open systems of the 85Rb D1 line by adding an incoherent optical pumping laser. This result raises a new question about recent theoretical work which does not address the degree of open. The pump beam only plays a role in transferring atoms by a spontaneous transition into the interacting system for EIT observation, which is an incoherent process. The dependence of the absorption spectra on the intensity and the polarization of each laser beam were observed. We have found the same tendencies in all transitions except the F = 2 ↔ F' = 3 transition of the 85Rb D1 line, which is the system that almost satisfies conventional EIA conditions.

  17. SOHO EIT Carrington maps from synoptic full-disk data

    Science.gov (United States)

    Thompson, B. J.; Newmark, J. S.; Gurman, J. B.; Delaboudiniere, J. P.; Clette, F.; Gibson, S. E.

    1997-01-01

    The solar synoptic maps, obtained from observations carried out since May 1996 by the extreme-ultraviolet imaging telescope (EIT) onboard the Solar and Heliospheric Observatory (SOHO), are presented. The maps were constructed for each Carrington rotation with the calibrated data. The off-limb maps at 1.05 and 1.10 solar radii were generated for three coronal lines using the standard applied to coronagraph synoptic maps. The maps reveal several aspects of the solar structure over the entire rotation and are used in the whole sun month modeling campaign. @txt extreme-ultraviolet imaging telescope

  18. Ethnic differences in objective and subjective skin irritation response: an international study.

    Science.gov (United States)

    Lee, E; Kim, S; Lee, J; Cho, S-A; Shin, K

    2014-08-01

    Due to global marketing in the cosmetics industry, it is important to assess ethnic population susceptibility when evaluating the safety of cosmetic products or chemicals. To investigate ethnic variations in skin irritation response to positive irritants. Clinical testing was performed in four countries on two ethnic groups - Asian and Caucasian. We performed patch tests on the subjects' back with 0.5% aqueous sodium lauryl sulfate (SLS) and 0.15% retinol prepared in 1,3-butylene glycol. Stinging tests were performed using 5% aqueous lactic acid and 0.001% (w/v) capsaicin prepared in 10% ethanol solution separately. The incidence of self-perceived skin sensitivity was similar in the two ethnic groups. However, the incidence of adverse skin reaction to cosmetics appeared significantly higher in Asian (33.0%) than in Caucasian subjects (11.3%). For standard positive irritants such as 0.5% aqueous SLS solution, Asian subjects showed significantly higher scores than Caucasian subjects. The incidence of positive reaction to the 0.15% retinol patch test tended to be higher in Asian than in Caucasian subjects. Our data also showed that neurosensitivity to 5% lactic acid and 0.001% capsaicin was higher in Asian than in Caucasian subjects. Although self-reported skin sensitivity does not appear to differ according to ethnicity, there are ethnic differences in objective and subjective skin irritation responses to several standard positive materials. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Stratum corneum cytokines and skin irritation response to sodium lauryl sulfate.

    Science.gov (United States)

    De Jongh, Cindy M; Verberk, Maarten M; Withagen, Carien E T; Jacobs, John J L; Rustemeyer, Thomas; Kezic, Sanja

    2006-06-01

    Little is known about cytokines involved in chronic irritant contact dermatitis. Individual cytokine profiles might explain at least part of the differences in the individual response to irritation. Our objective was to investigate the relation between baseline stratum corneum (SC) cytokine levels and the skin response to a single and a repeated irritation test. This study also aimed to determine changes in SC cytokine levels after repeated irritation. Transepidermal water loss (TEWL) and erythema were measured in 20 volunteers after single 24-hr exposure to 1% sodium lauryl sulfate (SLS), and during and after repeated exposure to 0.1% SLS over a 3-week period. SC cytokine levels were measured from an unexposed skin site and from the repeatedly exposed site. Interleukin (IL)-1alpha decreased by 30% after repeated exposure, while IL-1RA increased 10-fold and IL-8 increased fourfold. Baseline IL-1RA and IL-8 values were predictors of TEWL and erythema after single exposure (r = 0.55-0.61). 6 subjects showed barrier recovery during repeated exposure. Baseline IL-1RA and IL-8 levels are likely to be indicators of higher skin irritability after single exposure to SLS. Barrier repair in some of the subjects might explain the lack of agreement between the TEWL response after single and repeated irritation.

  20. EIT enhanced self-Kerr nonlinearity in the three-level lambda system under Doppler broadening

    International Nuclear Information System (INIS)

    Dinh Xuan Khoa; Le Van Doai; Pham Van Trong; Tran Manh Cuong; Vu Ngoc Sau; Nguyen Huy Bang; Le Nguyen Mai Anh

    2014-01-01

    Using density-matrix theory, an analytical expression of the self-Kerr nonlinear coefficient of a three-level lambda EIT medium for a weak probe light is derived. Influences of the coupling light and Doppler broadening on the self-Kerr coefficient are investigated and compared to experimental observation with a good agreement. The self-Kerr nonlinearity of the medium is modified and greatly enhanced in the spectral region of EIT window. Furthermore, sign, slope, and magnitude of the self-Kerr coefficient can be controlled with frequency and intensity of the coupling light and temperature of the medium. Specially, for a given set of fixed values of the parameters of coupling and probe lights, it could be able to choose an optimized temperature to have largest magnitude of the self-Kerr coefficient. Such controllable Kerr nonlinearity can find interesting applications in optoelectronic devices working with low-light intensity at various temperature conditions. (author)

  1. A new cell-based method for assessing the eye irritation potential of chemicals: an alternative to the Draize test.

    Science.gov (United States)

    Cho, Sun-A; An, Susun; Lee, Eunyoung; Shin, Kyeho; Cho, Jun-Cheol; Lee, Tae Ryong

    2012-07-20

    Using a human corneal cell line (HCE-T cells) and 2 evaluation criteria, we developed a new alternative method to assess the eye irritation potential of chemicals. We exposed HCE-T cells to different concentrations of 38 chemicals for 1h and measured relative cell viability (RCV) as an endpoint at each concentration. Using the RCV values, we calculated the RCV50. We also exposed HCE-T cells to 3 fixed concentrations of the 38 chemicals (5%, 0.5%, and 0.05%) for 1h and measured the RCV at each concentration. Using the RCV values at 5%, 0.5%, and 0.05%, we developed a new criterion for eye irritation potential (total eye irritation score, TEIS) and estimated the ocular irritancy. We then assessed the correlation of the results of RCV50 and TEIS with those of the Draize rabbit eye irritation. Both the RCV50 and TEIS results exhibited good positive correlations (sensitivity: 80.77%, specificity: 83.33%, and accuracy: 81.58% for TEIS; sensitivity: 73.08-76.92%, specificity: 75.00%, and accuracy: 73.68-76.32% for RCV50). We conclude that the new in vitro model using HCE-T cells is a good alternative evaluation model for the prediction of the eye irritation potential of chemicals. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Irritant Contact Dermatitis : Diagnosis and Risk Factors

    NARCIS (Netherlands)

    Schuttelaar, Maria; Johansen, Jeanne Duus; Lepoittevin, Jean-Pierre; Thyssen, Jacob P.

    2016-01-01

    Irritant contact dermatitis is frequent and is induced by direct and repeated contact with skin irritants such as detergents, abrasives, solvents and physical factors such as dry air and occlusion (by wearing gloves) but also water. When dermatitis has developed, even a minimal skin irritation, like

  3. Irritable bowel syndrome: contemporary nutrition management strategies.

    Science.gov (United States)

    Mullin, Gerard E; Shepherd, Sue J; Chander Roland, Bani; Ireton-Jones, Carol; Matarese, Laura E

    2014-09-01

    Irritable bowel syndrome is a complex disorder whose pathophysiology involves alterations in the enteric microbiota, visceral hypersensitivity, gut immune/barrier function, hypothalamic-pituitary-adrenal axis regulation, neurotransmitters, stress response, psychological factors, and more. The importance of diet in the management of irritable bowel syndrome has taken center stage in recent times as the literature validates the relationship of certain foods with the provocation of symptoms. Likewise, a number of elimination dietary programs have been successful in alleviating irritable bowel syndrome symptoms. Knowledge of the dietary management strategies for irritable bowel syndrome will help guide nutritionists and healthcare practitioners to deliver optimal outcomes. This tutorial reviews the nutrition management strategies for irritable bowel syndrome. © 2014 American Society for Parenteral and Enteral Nutrition.

  4. CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals.

    Science.gov (United States)

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2017-10-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. The hen's egg chorioallantoic membrane (HET-CAM) test to predict the ophthalmic irritation potential of a cysteamine-containing gel: Quantification using Photoshop® and ImageJ.

    Science.gov (United States)

    McKenzie, Barbara; Kay, Graeme; Matthews, Kerr H; Knott, Rachel M; Cairns, Donald

    2015-07-25

    A modified hen's egg chorioallantoic membrane (HET-CAM) test has been developed, combining ImageJ analysis with Adobe(®) Photoshop(®). The irritation potential of an ophthalmic medicine can be quantified using this method, by monitoring damage to blood vessels. The evaluation of cysteamine containing hyaluronate gel is reported. The results demonstrated that the novel gel formulation is non-irritant to the ocular tissues, in line with saline solution (negative control). In conclusion, the modification of the established HET-CAM test can quantify the damage to minute blood vessels. These results offer the possibility to formulate cysteamine in an ocular applicable gel formulation. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. EIT enhanced self-Kerr nonlinearity in the three-level lambda system under Doppler broadening

    International Nuclear Information System (INIS)

    Doai, Le Van; Khoa, Dinh Xuan; Bang, Nguyen Huy

    2015-01-01

    Using density-matrix theory, an analytical expression of the self-Kerr nonlinear coefficient of a three-level lambda EIT medium for a weak probe light is derived. Influences of the coupling light and Doppler broadening on the self-Kerr coefficient are investigated and compared to experimental observation with a good agreement. The self-Kerr nonlinearity of the medium is modified and greatly enhanced in the spectral region of EIT window. Furthermore, sign, slope, and magnitude of the self-Kerr coefficient can be controlled with frequency and intensity of the coupling light and temperature of the medium. In particular, for a given set of fixed values of the parameter coupling and probe lights, it is possible to choose an optimized temperature with which to obtain the largest magnitude of the self-Kerr coefficient. Such a controllable Kerr nonlinearity can find interesting applications in optoelectronic devices working with low-light intensity at various temperature conditions. (paper)

  7. Breast EIT using a new projected image reconstruction method with multi-frequency measurements.

    Science.gov (United States)

    Lee, Eunjung; Ts, Munkh-Erdene; Seo, Jin Keun; Woo, Eung Je

    2012-05-01

    We propose a new method to produce admittivity images of the breast for the diagnosis of breast cancer using electrical impedance tomography(EIT). Considering the anatomical structure of the breast, we designed an electrode configuration where current-injection and voltage-sensing electrodes are separated in such a way that internal current pathways are approximately along the tangential direction of an array of voltage-sensing electrodes. Unlike conventional EIT imaging methods where the number of injected currents is maximized to increase the total amount of measured data, current is injected only twice between two pairs of current-injection electrodes attached along the circumferential side of the breast. For each current injection, the induced voltages are measured from the front surface of the breast using as many voltage-sensing electrodes as possible. Although this electrode configurational lows us to measure induced voltages only on the front surface of the breast,they are more sensitive to an anomaly inside the breast since such an injected current tends to produce a more uniform internal current density distribution. Furthermore, the sensitivity of a measured boundary voltage between two equipotential lines on the front surface of the breast is improved since those equipotential lines are perpendicular to the primary direction of internal current streamlines. One should note that this novel data collection method is different from those of other frontal plane techniques such as the x-ray projection and T-scan imaging methods because we do not get any data on the plane that is perpendicular to the current flow. To reconstruct admittivity images using two measured voltage data sets, a new projected image reconstruction algorithm is developed. Numerical simulations demonstrate the frequency-difference EIT imaging of the breast. The results show that the new method is promising to accurately detect and localize small anomalies inside the breast.

  8. Breast EIT using a new projected image reconstruction method with multi-frequency measurements

    International Nuclear Information System (INIS)

    Lee, Eunjung; Ts, Munkh-Erdene; Seo, Jin Keun; Woo, Eung Je

    2012-01-01

    We propose a new method to produce admittivity images of the breast for the diagnosis of breast cancer using electrical impedance tomography (EIT). Considering the anatomical structure of the breast, we designed an electrode configuration where current-injection and voltage-sensing electrodes are separated in such a way that internal current pathways are approximately along the tangential direction of an array of voltage-sensing electrodes. Unlike conventional EIT imaging methods where the number of injected currents is maximized to increase the total amount of measured data, current is injected only twice between two pairs of current-injection electrodes attached along the circumferential side of the breast. For each current injection, the induced voltages are measured from the front surface of the breast using as many voltage-sensing electrodes as possible. Although this electrode configuration allows us to measure induced voltages only on the front surface of the breast, they are more sensitive to an anomaly inside the breast since such an injected current tends to produce a more uniform internal current density distribution. Furthermore, the sensitivity of a measured boundary voltage between two equipotential lines on the front surface of the breast is improved since those equipotential lines are perpendicular to the primary direction of internal current streamlines. One should note that this novel data collection method is different from those of other frontal plane techniques such as the x-ray projection and T-scan imaging methods because we do not get any data on the plane that is perpendicular to the current flow. To reconstruct admittivity images using two measured voltage data sets, a new projected image reconstruction algorithm is developed. Numerical simulations demonstrate the frequency-difference EIT imaging of the breast. The results show that the new method is promising to accurately detect and localize small anomalies inside the breast. (paper)

  9. The use of nanoencapsulation to decrease human skin irritation caused by capsaicinoids

    Directory of Open Access Journals (Sweden)

    Contri RV

    2014-02-01

    Full Text Available Renata V Contri,1 Luiza A Frank,2 Moacir Kaiser,1 Adriana R Pohlmann,1,3 Silvia S Guterres1,2 1Programa de Pós-Graduação em Ciências Farmacêuticas, 2Faculdade de Farmácia, 3Instituto de Química, Universidade Federal do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil Abstract: Capsaicin, a topical analgesic used in the treatment of chronic pain, has irritant properties that frequently interrupt its use. In this work, the effect of nanoencapsulation of the main capsaicinoids (capsaicin and dihydrocapsaicin on skin irritation was tested in humans. Skin tolerance of a novel vehicle composed of chitosan hydrogel containing nonloaded nanocapsules (CH-NC was also evaluated. The chitosan hydrogel containing nanoencapsulated capsaicinoids (CH-NC-CP did not cause skin irritation, as measured by an erythema probe and on a visual scale, while a formulation containing free capsaicinoids (chitosan gel with hydroalcoholic solution [CH-ET-CP] and a commercially available capsaicinoids formulation caused skin irritation. Thirty-one percent of volunteers reported slight irritation one hour after application of CH-NC-CP, while moderate (46% [CH-ET-CP] and 23% [commercial product] and severe (8% [CH-ET-CP] and 69% [commercial product] irritation were described for the formulations containing free capsaicinoids. When CH-NC was applied to the skin, erythema was not observed and only 8% of volunteers felt slight irritation, which demonstrates the utility of the novel vehicle. A complementary in vitro skin permeation study showed that permeation of capsaicinoids through an epidermal human membrane was reduced but not prevented by nanoencapsulation. Keywords: chitosan, nanocapsules, capsaicinoids, skin irritation, skin permeation

  10. Occupational allergic and irritant contact dermatitis in workers exposed to polyurethane foam

    Directory of Open Access Journals (Sweden)

    Marta Kieć-Świerczyńska

    2014-04-01

    Full Text Available Objectives: To evaluate sensitization to chemicals present in work environment after an outbreak of contact dermatitis in workers of vehicle equipment factory, exposed to polyurethane foam, based on 4,4'-diphenylmethane diisocyanate (MDI. Material and Methods: From among 300 employees, 21 individuals reporting work-related skin and/or respiratory tract symptoms underwent clinical examination, patch testing, skin prick tests, spirometry and MDI sIgE measurement in serum. Patch tests included isocyanates series, selected rubber additives, metals, fragrances, preservatives, and an antiadhesive agent. Results: Clinical examination revealed current eczema in the area of hands and/or forearms in 10 workers. Positive patch test reactions were found in 10 individuals, the most frequent to diaminodiphenylmethane and 4-phenylenediamine (7 persons. Reactions to an antiadhesive agent were assessed as irritant (5 workers. Except for sensitization to common aeroallergens, no significant abnormalities were found in the remaining tests. Occupational allergic contact dermatitis was diagnosed in 7 workers, irritant contact dermatitis in 10 and coexisiting allergic and irritant contact dermatitis in 3 workers. Conclusions: In workers manufacturing products from polyurethane foam, attention should be paid to the risk of developing contact dermatitis. Skin problems in our study group were attributable probably to insufficient protection of the skin.

  11. Benzalkonium chloride neutralizes the irritant effect of sodium dodecyl sulfate.

    Science.gov (United States)

    McFadden, J P; Holloway, D B; Whittle, E G; Basketter, D A

    2000-11-01

    When benzalkonium chloride (BKC), a cationic surfactant, is added to sodium dodecyl sulfate (SDS), an anionic surfactant, and used in patch testing, on the basis of their known physicochemical interaction, it is possible to predict that there will be a tendency towards a reduction in the expected irritant response when compared to SDS alone. The aim of this study was to investigate whether BKC could reduce the irritant response to SDS when applied after the SDS exposure. 54 non-atopic adult volunteers were recruited for the study. 20% SDS was applied for 2 h under occlusion. 1% BKC was then applied to the same site. Various controls, including SDS application followed by water for 2 h, were included. The irritant reaction was assessed at 24 h and 48 h. 40 of the 54 subjects had some reaction when SDS was applied for 2 h followed by either benzalkonium chloride or water control under occlusion. In comparison to water control, where BKC was applied after SDS, 20 of the 40 responders had a weaker reaction but only 4 had a stronger response. This study shows that BKC applied to skin exposed to SDS attenuates the resulting irritant reaction.

  12. [Changes of nitric oxide after trichloroethylene irritation in hairless mice skin and protection of ginkgo biloba extract and vitamin E].

    Science.gov (United States)

    Wang, Liang; Shen, Tong; Zhou, Cheng-fan; Yu, Jun-feng; Zhu, Qi-xing

    2009-04-01

    To study the changes of nitric oxide (NO) in the BALB/c hairless mice skin after trichloroethylene (TCE) irritation and the protection of ginkgo biloba extract (GbE) and vitamin E (VE). 132 BALB/c hairless mice were randomly divided into blank control group, solvent group (olive oil), TCE groups (20%TCE, 40%TCE, 80%TCE and 100%TCE), GbE groups (0.1%GbE, 1%GbE and 10%GbE) and VE groups (5%VE, 10% VE and 20% VE), with 11 animals in each group, 5 for acute irritation test and 6 for the cumulative irritation test. The skin irritation was observed, and the levels of NO in the dorsal skin of BALB/C hairless mice were detected. The kit of NO was used to detect the levels of NO in the dorsal skin of BALB/c hairless mice. (1) The skin presented erythema and edema after TCE irritation both in acute irritation and cumulative irritation test and the skin inflammation showed time-dose effect relationship; the mice skin was protected in GbE or VE groups. (2) In the acute stimulation test, the levels of NO in 80%TCE group (69.895 +/- 9.605 micromol/mg pro) and 100%TCE group (77.273 +/- 9.290 micromol/mg pro) were significantly different compared with blank control group and solvent control group (P skin of BALB/c hairless mice and induce the significant increase of the NO levels. GbE and VE can protect the skin from TCE irritation damage.

  13. Irritability Levels of Field and Laboratory Population of Culex pipiens Complex in Tehran to Different Groups of Insecticides

    Directory of Open Access Journals (Sweden)

    Sara Rahimi

    2016-01-01

    Full Text Available Background: The irritant effect of some insecticides can cause a proportion of mosquitoes to leave the sprayed rooms before acquiring a lethal dose, so the repeated contact al sub-lethal dose may lead to extent the resistance.Methods: Larvae and pupae of Culex pipiens complex were collected in mass from open canals of waste water in capital city Tehran and reared to obtain the first generation at laboratory. Sugar-fed 2–3 days female mosquitoes were used for the experiments and compared with laboratory strain. The irritability tests of insecticides impregnated pa­pers were measured in plastic conical exposure chambers placed which implemented at controlled conditions ac­cording  to  the  method  described  by WHO .Number of take-offs were counted during 15  minutes of exposure  time.Results: DDT had the most irritancy effect against field population of Cx. pipiens. DDT, permethrin and deltamethrin was moderately irritable against laboratory strain, whereas, addition to three previous insecticides, malathion, cyfluthrin and propoxur should be also considered as moderately irritable insecticides for field population of. Irritability level of etofenprox, fenithrothion, bendiocarb, and lambdacyhalothrin did not differ from control group.Conclusion: The irritability response of mosquitoes may have a negative impact on control measures. Periodical execution of irritability tests with insecticides that routinely used in vector control program is highly recommended.

  14. Application of SV40 T-transformed human corneal epithelial cells to evaluate potential irritant chemicals for in vitro alternative eye toxicity.

    Science.gov (United States)

    Kim, Cho-Won; Park, Geon-Tae; Bae, Ok-Nam; Noh, Minsoo; Choi, Kyung-Chul

    2016-01-01

    Assessment of eye irritation potential is important to human safety, and it is necessary for various cosmetics and chemicals that may contact the human eye. Until recently, the Draize test was considered the standard method for estimating eye irritation, despite its disadvantages such as the need to sacrifice many rabbits for subjective scoring. Thus, we investigated the cytotoxicity and inflammatory response to standard eye irritants using SV40 T-transformed human corneal epithelial (SHCE) cells as a step toward development of an animal-free alternative eye irritation test. MTT and NRU assays of cell viability were performed to investigate the optimal experimental conditions for SHCE cell viability when cells were exposed to sodium dodecyl sulfate (SDS) as a standard eye irritant at 6.25×10(-3) to 1×10(-1)%. Additionally, cell viability of SHCE cells was examined in response to six potential eye irritants, benzalkonium chloride, dimethyl sulfoxide, isopropanol, SDS, Triton X-100 and Tween 20 at 5×10(-3) to 1×10(-1)%. Finally, we estimated the secretion level of cytokines in response to stimulation by eye irritants in SHCE cells. SHCE cells showed a good response to potential eye irritants when the cells were exposed to potential irritants for 10min at room temperature (RT), and cytokine production increased in a concentration-dependent manner, indicating that cytotoxicity and cytokine secretion from SHCE cells may be well correlated with the concentrations of irritants. Taken together, these results suggest that SHCE cells could be an excellent alternative in vitro model to replace in vivo animal models for eye irritation tests. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. The Frequency Spectral Properties of Electrode-Skin Contact Impedance on Human Head and Its Frequency-Dependent Effects on Frequency-Difference EIT in Stroke Detection from 10Hz to 1MHz.

    Directory of Open Access Journals (Sweden)

    Lin Yang

    Full Text Available Frequency-difference electrical impedance tomography (fdEIT reconstructs frequency-dependent changes of a complex impedance distribution. It has a potential application in acute stroke detection because there are significant differences in impedance spectra between stroke lesions and normal brain tissues. However, fdEIT suffers from the influences of electrode-skin contact impedance since contact impedance varies greatly with frequency. When using fdEIT to detect stroke, it is critical to know the degree of measurement errors or image artifacts caused by contact impedance. To our knowledge, no study has systematically investigated the frequency spectral properties of electrode-skin contact impedance on human head and its frequency-dependent effects on fdEIT used in stroke detection within a wide frequency band (10 Hz-1 MHz. In this study, we first measured and analyzed the frequency spectral properties of electrode-skin contact impedance on 47 human subjects' heads within 10 Hz-1 MHz. Then, we quantified the frequency-dependent effects of contact impedance on fdEIT in stroke detection in terms of the current distribution beneath the electrodes and the contact impedance imbalance between two measuring electrodes. The results showed that the contact impedance at high frequencies (>100 kHz significantly changed the current distribution beneath the electrode, leading to nonnegligible errors in boundary voltages and artifacts in reconstructed images. The contact impedance imbalance at low frequencies (<1 kHz also caused significant measurement errors. We conclude that the contact impedance has critical frequency-dependent influences on fdEIT and further studies on reducing such influences are necessary to improve the application of fdEIT in stroke detection.

  16. The Frequency Spectral Properties of Electrode-Skin Contact Impedance on Human Head and Its Frequency-Dependent Effects on Frequency-Difference EIT in Stroke Detection from 10Hz to 1MHz.

    Science.gov (United States)

    Yang, Lin; Dai, Meng; Xu, Canhua; Zhang, Ge; Li, Weichen; Fu, Feng; Shi, Xuetao; Dong, Xiuzhen

    2017-01-01

    Frequency-difference electrical impedance tomography (fdEIT) reconstructs frequency-dependent changes of a complex impedance distribution. It has a potential application in acute stroke detection because there are significant differences in impedance spectra between stroke lesions and normal brain tissues. However, fdEIT suffers from the influences of electrode-skin contact impedance since contact impedance varies greatly with frequency. When using fdEIT to detect stroke, it is critical to know the degree of measurement errors or image artifacts caused by contact impedance. To our knowledge, no study has systematically investigated the frequency spectral properties of electrode-skin contact impedance on human head and its frequency-dependent effects on fdEIT used in stroke detection within a wide frequency band (10 Hz-1 MHz). In this study, we first measured and analyzed the frequency spectral properties of electrode-skin contact impedance on 47 human subjects' heads within 10 Hz-1 MHz. Then, we quantified the frequency-dependent effects of contact impedance on fdEIT in stroke detection in terms of the current distribution beneath the electrodes and the contact impedance imbalance between two measuring electrodes. The results showed that the contact impedance at high frequencies (>100 kHz) significantly changed the current distribution beneath the electrode, leading to nonnegligible errors in boundary voltages and artifacts in reconstructed images. The contact impedance imbalance at low frequencies (<1 kHz) also caused significant measurement errors. We conclude that the contact impedance has critical frequency-dependent influences on fdEIT and further studies on reducing such influences are necessary to improve the application of fdEIT in stroke detection.

  17. Long-term repetitive sodium lauryl sulfate-induced irritation of the skin: an in vivo study.

    Science.gov (United States)

    Branco, Nara; Lee, Ivy; Zhai, Hongbo; Maibach, Howard I

    2005-11-01

    Skin may adapt to topical irritants through accommodation. This study focuses on long-term exposure to irritants and attempts to demonstrate accommodation. Sodium lauryl sulfate (SLS) induced irritant contact dermatitis at 3 concentrations (0.025% to 0.075%). Distilled water, acetone and an empty chamber served as controls. Experimental compounds were applied to forearms of 7 healthy volunteers for 24 hr before replacing by a fresh chamber for 6 non-consecutive weeks over 103 days. Possible accommodation was quantified by visual scoring (erythema and dryness) and by bioengineering parameters: transepidermal water loss (TEWL), capacitance, chromametry and laser Doppler flowmetry (LDF). Significant erythema, dryness, elevated TEWL, skin colour reflectance and LDF values occurred during the exposure periods. Upon repeat exposure, an immediate and augmented response in erythema, TEWL, skin colour reflectance and LDF developed. However, irritant skin changes were not sustained. Irritation parameters return to baseline after cessation of exposure. There was no evidence of sustained irritation or accommodation after the last exposure. Study findings do not document sustained accommodation or adaptive hyposensitivity after long-term repetitive irritant exposure under these test conditions. Alternative models should be developed to prove or disprove the accommodation hypothesis.

  18. Cutaneous irritancy of an ibuprofen medicated plaster in healthy volunteers.

    Science.gov (United States)

    Maganji, Manisha; Connolly, Mark P; Bhatt, Aomesh

    2018-04-01

    To assess the irritation and contact sensitization potential of a 200 mg ibuprofen medicated plaster. This double-blind, phase-1 placebo controlled study had two phases; the induction phase to evaluate the irritant potential of continuous application of the plaster, and the challenge phase to assess contact sensitivity (allergy). The cumulative irritancy potential was evaluated using an adaptation of the Shelanski method. Healthy adults (≥18 years of age) (N = 210) were treated simultaneously with one ibuprofen medicated and one placebo plaster applied in a randomized fashion to either the left or right side of the lower back. During the induction phase, plasters were applied on Days 1, 3, 5, 8, 10, 12, 15, 17, and 19 and the final plaster removed on Day 22. At each scheduled visit plasters and applications sites were assessed for degree of adhesion and skin irritation (score of 1 = no irritation to 7 = strong reaction spreading beyond test sites), respectively. The challenge phase followed a two-week washout period. A plaster was applied on Day 36 for 48 h and assessment occurred on Days 38, 39, and 40. The mean cumulative irritation score during the induction phase was lower for the ibuprofen medicated plaster than the placebo plaster (0.32 vs. 1.23, respectively). Three (1.4%) subjects experience a dermal reaction of grade ≥3 for the ibuprofen medicated plaster compared with 27 (12.7%) for the placebo plaster. Following challenge with ibuprofen or placebo plasters, 12 subjects (6.2%) with the ibuprofen medicated plaster and four (2.2%) with the placebo plaster had skin reaction of assessment grade higher than the induction phase. One subject for the ibuprofen and two for the placebo plaster had reactions with grade >2. No subjects showed an increase in sensitization on Day 39 or 40 compared with Day 38. The findings indicate that the both the irritancy and contact sensitization of the ibuprofen medicated plaster is acceptable.

  19. Ventilation area measured with eit in order to optimize peep settings in mechanically ventilated patients

    NARCIS (Netherlands)

    Blankman, P; Groot Jebbink, E; Preis, C; Bikker, I.; Gommers, D.

    2012-01-01

    INTRODUCTION. Electrical Impedance Tomography (EIT) is a non-invasive imaging technique, which can be used to visualize ventilation. Ventilation will be measured by impedance changes due to ventilation. OBJECTIVES. The aim of this study was to optimize PEEP settings based on the ventilation area of

  20. Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR-EIT and its performance with different probing current patterns

    International Nuclear Information System (INIS)

    Birguel, Oezlem; Eyueboglu, B Murat; Ider, Y Ziya

    2003-01-01

    Conventional injected-current electrical impedance tomography (EIT) and magnetic resonance imaging (MRI) techniques can be combined to reconstruct high resolution true conductivity images. The magnetic flux density distribution generated by the internal current density distribution is extracted from MR phase images. This information is used to form a fine detailed conductivity image using an Ohm's law based update equation. The reconstructed conductivity image is assumed to differ from the true image by a scale factor. EIT surface potential measurements are then used to scale the reconstructed image in order to find the true conductivity values. This process is iterated until a stopping criterion is met. Several simulations are carried out for opposite and cosine current injection patterns to select the best current injection pattern for a 2D thorax model. The contrast resolution and accuracy of the proposed algorithm are also studied. In all simulation studies, realistic noise models for voltage and magnetic flux density measurements are used. It is shown that, in contrast to the conventional EIT techniques, the proposed method has the capability of reconstructing conductivity images with uniform and high spatial resolution. The spatial resolution is limited by the larger element size of the finite element mesh and twice the magnetic resonance image pixel size

  1. Assessment of Irritation and Sensitization Potential of Eight Baby Skin Care Products.

    Science.gov (United States)

    Galzote, Carlos; Thomas, Mini; Sachdev, Mukta

    2016-10-01

    Ethnic differences in skin sensitivity suggest that greater emphasis be focused on understanding a product's effect in diverse populations. The irritation and/or sensitization potential of 8 baby skin care products in Indian adults were evaluated using cumulative irritation tests (CIT) and human repeat insult patch testing (HRIPT) protocols. Healthy males or females aged 18 to 65 years of Indian ethnicity were treated with each of 6 products (cream, hair oil, lotion, body wash, shampoo, and baby soap) using CIT (n = 25) and HRIPT (n = 200). Baby powder and baby oil were evaluated by CIT (n = 25) and HRIPT (n = 107) in separate studies. CITs were conducted over 14 days; HRIPTs were conducted over 10 weeks. In both CIT and HRIPT, most products were considered mild, with no irritation. Baby soap and powder elicited reactions in the HRIPT induction phase, with positive challenge phase reactions (3 subjects), but were affirmed to be nonallergenic in the rechallenge phase. In these studies, 8 baby skin care products were evaluated by both CIT and HRIPT in Indian adults. The results of the studies indicated that all of the tested products were nonallergenic and nonirritating. J Drugs Dermatol. 2016;15(10):1244-1248.

  2. Developmental trajectories of irritability and bidirectional associations with maternal depression.

    Science.gov (United States)

    Wiggins, Jillian Lee; Mitchell, Colter; Stringaris, Argyris; Leibenluft, Ellen

    2014-11-01

    Irritability is a dimensional trait in typical development and a common presenting symptom in many psychiatric disorders, including depression. However, little is known about the developmental trajectory of irritability or how child irritability interacts with maternal depression. The present study identifies classes of irritability trajectories from toddlerhood to middle childhood; characterizes maternal depression and other family, social environment, and child variables within each irritability trajectory class; and, as a more exploratory analysis, examines bidirectional associations between maternal depression and child irritability. A total of 4,898 families from the Fragile Families and Child Wellbeing Study reported on irritability symptoms at ages 3, 5, and 9 years, assessed with items from the Child Behavior Checklist. Parental major depressive episode was assessed using the Composite International Diagnostic Interview-Short Form at child ages 1, 3, 5, and 9 years. A latent class growth analysis identified 5 irritability classes: low decreasing; moderate decreasing; high steady; initially very high, then decreasing; and high increasing. Children with more severe irritability trajectories are more likely to have mothers with recurrent depression, and, with the exception of the most severe (high increasing irritability) class, were more likely to have mothers who were exposed to violence. Moreover, paternal depression and alcohol abuse, as well as maternal drug and alcohol abuse, were also risk factors for membership in the more severe irritability classes. A latent auto-regressive cross-lag model showed that child irritability at ages 3 and 5 years is associated with increased mother depression at ages 5 and 9, respectively. Conversely, mother depression at child ages 1 and 3 years is associated with increased child irritability at 3 and 5. Irritability development across toddlerhood and middle childhood has 5 main trajectory types, which differ on maternal

  3. Neurobiology of Depression and Irritable Bowel Syndrome Comorbidity

    Directory of Open Access Journals (Sweden)

    Ozlem Donat Eker

    2009-08-01

    Full Text Available Irritable bowel syndrome is a disabling functional disorder with a frequent comorbidity of depression though underlying mechanisms remain yet little understood. Various signs and symptoms have been determined as diagnostic criteria in recent years and standardized as Rome-III criteria. Irritable bowel syndrome can have constipation-dominant, diarrhea-dominant or mixed clinical presentations. Main features can be summarized as continuous and recurrent abdominal pain or discomfort associated with a change of stool frequency or consistency and usually relief of symptoms with defe-cation in the absence of physical or laboratory abnormalities indicative of an organic etiology. The frequency of major depressive disorder diagnosis reaches up to two thirds of irritable bowel syndrome patients. Moreover, the comorbidity of irritable bowel syndrome among patients with major depression is highly frequent (30%. The mechanism underlying irritable bowel syndrome which have been considered as a kind of a somatization disorder for a long time and now as a functional bowel disease is in the brain-gut axis. Low grade mucosal inflammation and cytokines originating from mucosal inflammation have important functions in the pathophysiology of irritable bowel syndrome and its comorbidity with major depression. Besides the inflammatory factors lumbosacral visceral hyperexcitability which is an individual variation is proposed as the main underlying cause of irritable bowel syndrome. Visceral hyper-excitability is mediated by cytokines and neuro-mediators and stress is known to increase the effect of this mechanism. Furthermore, molecules participating in this mechanism (e.g. cytokines, corticotrophin releasing factor, neurokinins and monoamines play important roles in the pathophysiology of depression. Increased activation in the pain matrix (thalamus – insula – prefrontal cortex and insufficiency of endogenous pain inhibitory system are regarded as possible

  4. Lactose Intolerance and the Irritable Colon

    OpenAIRE

    McSherry, J. A.

    1982-01-01

    Symptoms of lactase deficiency include nausea, abdominal pain, distension, bloating and diarrhea after ingesting foods which contain lactose. Lactose intolerance and bowel motility disorders have similar symptoms, and people with irritable bowel syndrome and unexplained abdominal pain may have lactose intolerance. A definite diagnosis can be made by detecting hydrogen in the breath after a lactose load, by lactase assay from a small bowel biopsy specimen or by lactose intolerance testing. Lac...

  5. Contrast enhancement in EIT imaging of the brain

    International Nuclear Information System (INIS)

    Nissinen, A; Kaipio, J P; Vauhkonen, M; Kolehmainen, V

    2016-01-01

    We consider electrical impedance tomography (EIT) imaging of the brain. The brain is surrounded by the poorly conducting skull which has low conductivity compared to the brain. The skull layer causes a partial shielding effect which leads to weak sensitivity for the imaging of the brain tissue. In this paper we propose an approach based on the Bayesian approximation error approach, to enhance the contrast in brain imaging. With this approach, both the (uninteresting) geometry and the conductivity of the skull are embedded in the approximation error statistics, which leads to a computationally efficient algorithm that is able to detect features such as internal haemorrhage with significantly increased sensitivity and specificity. We evaluate the approach with simulations and phantom data. (paper)

  6. Contrast enhancement in EIT imaging of the brain.

    Science.gov (United States)

    Nissinen, A; Kaipio, J P; Vauhkonen, M; Kolehmainen, V

    2016-01-01

    We consider electrical impedance tomography (EIT) imaging of the brain. The brain is surrounded by the poorly conducting skull which has low conductivity compared to the brain. The skull layer causes a partial shielding effect which leads to weak sensitivity for the imaging of the brain tissue. In this paper we propose an approach based on the Bayesian approximation error approach, to enhance the contrast in brain imaging. With this approach, both the (uninteresting) geometry and the conductivity of the skull are embedded in the approximation error statistics, which leads to a computationally efficient algorithm that is able to detect features such as internal haemorrhage with significantly increased sensitivity and specificity. We evaluate the approach with simulations and phantom data.

  7. Skin irritation, false positives and the local lymph node assay: a guideline issue?

    Science.gov (United States)

    Basketter, David A; Kimber, Ian

    2011-10-01

    Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Antioxidant activity and irritation property of venoms from Apis species.

    Science.gov (United States)

    Somwongin, Suvimol; Chantawannakul, Panuwan; Chaiyana, Wantida

    2018-04-01

    Pharmacological effects of bee venom has been reported, however, it has been restricted to the bee venom collected from European honey bee (Apis mellifera). The aim of the present study was to compare the antioxidant activities and irritation properties of venoms collected from four different Apis species in Thailand, which includes Apis cerena (Asian cavity nesting honeybee), Apis florea (dwarf honeybee), Apis dorsata (giant honeybee), and A. mellifera. Melittin content of each bee venom extracts was investigated by using high-performance liquid chromatography. Ferric reducing antioxidant power, 2, 2'-azinobis (3-ethylbenzothiazoline-6-sulfonic acid), and 1, 1-diphenyl-2-picrylhydrazyl assay were used to determine the antioxidant activity, whereas, hen's egg test chorioallantoic membrane assay was used to determine the irritation property of each bee venom extracts. Melittin was the major constituent in all bee venom extracts. The melittin content in A. dorsata, A. mellifera, A. florea, and A. cerena were 95.8 ± 3.2%, 76.5 ± 1.9%, 66.3 ± 8.6%, and 56.8 ± 1.8%, respectively. Bee venom extract from A. dorsata possessed the highest antioxidant activity with the inhibition of 41.1 ± 2.2% against DPPH, Trolox equivalent antioxidant capacity of 10.21 ± 0.74 mM Trolox/mg and equivalent concentration (EC 1 ) of 0.35 ± 0.02 mM FeSO 4 /mg. Bee venom extract from A. mellifera exhibited the highest irritation, followed by A. cerena, A. dorsata, and A. florea, respectively. Melittin was the compound responsible for the irritation property of bee venom extracts since it could induce severe irritation (irritation score was 13.7 ± 0.5, at the concentration of 2 mg/ml). The extract from A. dorsata which possessed the highest antioxidant activity showed no irritation up to the concentration of 0.1 mg/ml. Therefore, bee venom extract from A. dorsata at the concentration not more than 0.1 mg/ml would be suggested for using

  9. Applications for Electrical Impedance Tomography (EIT) and Electrical Properties of the Human Body.

    Science.gov (United States)

    Lymperopoulos, Georgios; Lymperopoulos, Panagiotis; Alikari, Victoria; Dafogianni, Chrisoula; Zyga, Sofia; Margari, Nikoletta

    2017-01-01

    Electrical Impedance Tomography (EIT) is a promising application that displays changes in conductivity within a body. The basic principle of the method is the repeated measurement of surface voltages of a body, which are a result of rolling injection of known and small-volume sinusoidal AC current to the body through the electrodes attached to its surface. This method finds application in biomedicine, biology and geology. The objective of this paper is to present the applications of Electrical Impedance Tomography, along with the method's capabilities and limitations due to the electrical properties of the human body. For this purpose, investigation of existing literature has been conducted, using electronic databases, PubMed, Google Scholar and IEEE Xplore. In addition, there was a secondary research phase, using paper citations found during the first research phase. It should be noted that Electrical Impedance Tomography finds use in a plethora of medical applications, as the different tissues of the body have different conductivities and dielectric constants. Main applications of EIT include imaging of lung function, diagnosis of pulmonary embolism, detection of tumors in the chest area and diagnosis and distinction of ischemic and hemorrhagic stroke. EIT advantages include portability, low cost and safety, which the method provide, since it is a noninvasive imaging method that does not cause damage to the body. The main disadvantage of the method, which blocks its wider spread, appears in the image composition from the voltage measurements, which are conducted by electrodes placed on the periphery of the body, because the injected currents are affected nonlinearly by the general distribution of the electrical properties of the body. Furthermore, the complex impedance of the skin-electrode interface can be modelled by using a capacitor and two resistor, as a result of skin properties. In conclusion, Electrical Impedance Tomography is a promising method for the

  10. Comparison of cytotoxicity in vitro and irritation in vivo for aqueous and oily solutions of surfactants.

    Science.gov (United States)

    Czajkowska-Kośnik, Anna; Wolska, Eliza; Chorążewicz, Juliusz; Sznitowska, Małgorzata

    2015-01-01

    The in vivo model on rabbit eyes and the in vitro cytotoxicity on fibroblasts were used to compare irritation effect of aqueous and oily (Miglyol 812) solutions of surfactants. Tween 20, Tween 80 and Cremophor EL were tested in different concentrations (0.1, 1 or 5%) and the in vitro test demonstrated that surfactants in oil are less cytotoxic than in aqueous solutions. In the in vivo study, the aqueous solutions of surfactants were characterized as non-irritant while small changes in conjunctiva were observed after application the oily solutions of surfactants and the preparations were classified as slightly irritant, however this effect was similar when Miglyol was applied alone. In conclusion, it is reported that the MTT assay does not correlate well with the Draize scores.

  11. Regularization of EIT reconstruction based on multi-scales wavelet transforms

    Directory of Open Access Journals (Sweden)

    Gong Bo

    2016-09-01

    Full Text Available Electrical Impedance Tomography (EIT intends to obtain the conductivity distribution of a domain from the electrical boundary conditions. This is an ill-posed inverse problem usually solved on finite element meshes. Wavelet transforms are widely used for medical image reconstruction. However, because of the irregular form of the finite element meshes, the canonical wavelet transforms is impossible to perform on meshes. In this article, we present a framework that combines multi-scales wavelet transforms and finite element meshes by viewing meshes as undirected graphs and applying spectral graph wavelet transform on the meshes.

  12. Reprint of "CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals".

    Science.gov (United States)

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2018-06-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Evaluating skin-protective materials against contact irritants and allergens. An in vivo screening human model.

    Science.gov (United States)

    Zhai, H; Willard, P; Maibach, H I

    1998-03-01

    2 acute irritants and 1 allergen were selected: sodium lauryl sulfate (SLS) representative of irritant household and occupational contact dermatitis, the combination of ammonium hydroxide (NH4OH) and urea to simulate diaper dermatitis, and Rhus to evaluate the effect of model protective materials. The putative protective materials and vehicle were applied to both ventral forearms of 10 subjects in each group, according to a randomized code. Test materials were spread over a marked 2.0 cm2 area, massaged in, allowed to dry for 30 min, and reapplied with another 30 min drying period. The model irritants and allergen were then applied (0.025 ml) to an Al-test occlusive patch, which in turn was placed for 24 h over each of the 8 designated sites. Inflammation was scored according to a clinical scale 72 h post-application. Paraffin wax plus Acetulan in cetyl alcohol, and beeswax plus Acetulan in cetyl alcohol, markedly (p < 0.001) suppressed SLS irritation. Paraffin wax plus beeswax in cetyl alcohol, and Acetulan in cetyl alcohol reduced NH4OH and urea irritation (p < 0.05), paraffin wax in cetyl alcohol significantly (p < 0.01) decreasing Rhus allergic contact dermatitis. This model, provides an easy approach to screening protectants. Its clinical significance requires comparison with an open rather than an occluded challenge.

  14. IRRITATED BOWEL SYNDROME IN CHILDREN

    Directory of Open Access Journals (Sweden)

    V. F. Privorotskiy

    2012-01-01

    Full Text Available Irritated bowel syndrome is a significant and underestimated problem in childhood. This condition is not so good studied in pediatrics in comparison with adult practice. Pediatricians often diagnosed this disease in infants and young children without proper reasons. The authors analyze current opinions about etiology and pathogenesis, clinical presentation, diagnosticsand treatment of irritated bowel syndrome in children. An emphasis is made on diagnostic criteria, which allow suggesting and confirming the diagnosis.

  15. Tunable Optical True-Time Delay Devices Would Exploit EIT

    Science.gov (United States)

    Kulikov, Igor; DiDomenico, Leo; Lee, Hwang

    2004-01-01

    Tunable optical true-time delay devices that would exploit electromagnetically induced transparency (EIT) have been proposed. Relative to prior true-time delay devices (for example, devices based on ferroelectric and ferromagnetic materials) and electronically controlled phase shifters, the proposed devices would offer much greater bandwidths. In a typical envisioned application, an optical pulse would be modulated with an ultra-wideband radio-frequency (RF) signal that would convey the information that one seeks to communicate, and it would be required to couple differently delayed replicas of the RF signal to the radiating elements of a phased-array antenna. One or more of the proposed devices would be used to impose the delays and/or generate the delayed replicas of the RF-modulated optical pulse. The beam radiated or received by the antenna would be steered by use of a microprocessor-based control system that would adjust operational parameters of the devices to tune the delays to the required values. EIT is a nonlinear quantum optical interference effect that enables the propagation of light through an initially opaque medium. A suitable medium must have, among other properties, three quantum states (see Figure 1): an excited state (state 3), an upper ground state (state 2), and a lower ground state (state 1). These three states must form a closed system that exhibits no decays to other states in the presence of either or both of two laser beams: (1) a probe beam having the wavelength corresponding to the photon energy equal to the energy difference between states 3 and 1; and (2) a coupling beam having the wavelength corresponding to the photon energy equal to the energy difference between states 3 and 2. The probe beam is the one that is pulsed and modulated with an RF signal.

  16. Investigation of acute dermal irritation/corrosion, acute inhalation toxicity and cytotoxicity tests for Nanobiocide®

    Directory of Open Access Journals (Sweden)

    Mansour Hemmati

    2016-07-01

    Full Text Available Objective(s: Nanomaterials, especially silver Nanoparticles (Ag-NPs, are employed in an increasing number of commercial products. This has led to an ever growing exposure of human beings to this substance. The first purpose of the Nano Committee of Food and Drug Administration of The Islamic Republic of Iran (IFDA is developing guidelines to assess and approve commercial nano-health products for their safety of human applications. Nanobiocide® as a commercial product of stable colloid including 2000 ppm Ag-NPs for surface antimicrobial applications was investigated according to IFDA guidelines in the approval process. Methods: The first fabrication and characterization method of the product were determined. The human exposure to Nanobiocide® were studied by cytotoxicity assay, dermal irritation and inhalation toxicity assay based on the standard assay. Results: According to cytotoxicity assay by MTT method the concentration-dependent of cell viability was reduced and Inhibitory concentration-50 was about 1160 ppm. The Draize dermal irritation scoring system (DDIS showed no irritation to the skin of rabbits. No sign of gross toxicity, adverse pharmacological effect, or abnormal behavior based on inhalation toxicity was observed. Conclusions: The consideration of toxicity of Nanobiocide® is one of the major key for medical application. The results obtained revealed that the Nanobiocide® may be safe using in domestic and veterinary applications.

  17. In vitro assessment of skin irritation potential of surfactant-based formulations by using a 3-D skin reconstructed tissue model and cytokine response.

    Science.gov (United States)

    Walters, Russel M; Gandolfi, Lisa; Mack, M Catherine; Fevola, Michael; Martin, Katharine; Hamilton, Mathew T; Hilberer, Allison; Barnes, Nicole; Wilt, Nathan; Nash, Jennifer R; Raabe, Hans A; Costin, Gertrude-Emilia

    2016-12-01

    The personal care industry is focused on developing safe, more efficacious, and increasingly milder products, that are routinely undergoing preclinical and clinical testing before becoming available for consumer use on skin. In vitro systems based on skin reconstructed equivalents are now established for the preclinical assessment of product irritation potential and as alternative testing methods to the classic Draize rabbit skin irritation test. We have used the 3-D EpiDerm™ model system to evaluate tissue viability and primary cytokine interleukin-1α release as a way to evaluate the potential dermal irritation of 224 non-ionic, amphoteric and/or anionic surfactant-containing formulations, or individual raw materials. As part of our testing programme, two representative benchmark materials with known clinical skin irritation potential were qualified through repeated testing, for use as references for the skin irritation evaluation of formulations containing new surfactant ingredients. We have established a correlation between the in vitro screening approach and clinical testing, and are continually expanding our database to enhance this correlation. This testing programme integrates the efforts of global manufacturers of personal care products that focus on the development of increasingly milder formulations to be applied to the skin, without the use of animal testing. 2016 FRAME.

  18. Improving image quality in Electrical Impedance Tomography (EIT using Projection Error Propagation-based Regularization (PEPR technique: A simulation study

    Directory of Open Access Journals (Sweden)

    Tushar Kanti Bera

    2011-03-01

    Full Text Available A Projection Error Propagation-based Regularization (PEPR method is proposed and the reconstructed image quality is improved in Electrical Impedance Tomography (EIT. A projection error is produced due to the misfit of the calculated and measured data in the reconstruction process. The variation of the projection error is integrated with response matrix in each iterations and the reconstruction is carried out in EIDORS. The PEPR method is studied with the simulated boundary data for different inhomogeneity geometries. Simulated results demonstrate that the PEPR technique improves image reconstruction precision in EIDORS and hence it can be successfully implemented to increase the reconstruction accuracy in EIT.>doi:10.5617/jeb.158 J Electr Bioimp, vol. 2, pp. 2-12, 2011

  19. A reassessment of the in vitro RBC haemolysis assay with defibrinated sheep blood for the determination of the ocular irritation potential of cosmetic products: comparison with the in vivo Draize rabbit test.

    Science.gov (United States)

    Alves, Eloísa Nunes; Presgrave, Rosaura de Farias; Presgrave, Octávio Augusto França; Sabagh, Fernanda Peres; de Freitas, João Carlos Borges Rolim; Corrado, Alexandre P

    2008-07-01

    We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (DI); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.

  20. Occupational irritant contact dermatitis diagnosed by analysis of contact irritants and allergens in the work environment

    DEFF Research Database (Denmark)

    Friis, Ulrik F; Menné, Torkil; Schwensen, Jakob F

    2014-01-01

    BACKGROUND: Irritant contact dermatitis (ICD) is a common diagnosis in patients with occupational contact dermatitis (OCD). Studies are lacking on the usefulness of material safety data sheets (MSDSs) in making the diagnosis of ICD. OBJECTIVE: To characterize irritant exposures leading...... to the diagnosis of occupational ICD (OICD), and to evaluate the occurrence of concomitant exposures to contact allergens. METHODS: We included 316 patients with suspected occupational hand dermatitis, referred to the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte, Denmark during......), mechanical traumas (n = 19), and oils (n = 15). Exposure to specific irritant chemicals was found in 9 patients, and was identified from MSDSs/ingredients labelling in 8 of these patients. Review of MSDSs and ingredients labelling showed that 41 patients were exposed to 41 moderate to potent contact...

  1. Dissecting the role of TRPV1 in detecting multiple trigeminal irritants in three behavioral assays for sensory irritation [v1; ref status: indexed, http://f1000r.es/p8

    Directory of Open Access Journals (Sweden)

    CJ Saunders

    2013-03-01

    Full Text Available Polymodal neurons of the trigeminal nerve innervate the nasal cavity, nasopharynx, oral cavity and cornea. Trigeminal nociceptive fibers express a diverse collection of receptors and are stimulated by a wide variety of chemicals. However, the mechanism of stimulation is known only for relatively few of these compounds. Capsaicin, for example, activates transient receptor potential vanilloid 1 (TRPV1 channels. In the present study, wildtype (C57Bl/6J and TRPV1 knockout mice were tested in three behavioral assays for irritation to determine if TRPV1 is necessary to detect trigeminal irritants in addition to capsaicin. In one assay mice were presented with a chemical via a cotton swab and their response scored on a 5 level scale. In another assay, a modified two bottle preference test, which avoids the confound of mixing irritants with the animal’s drinking water, was used to assess aversion. In the final assay, an air dilution olfactometer was used to administer volatile compounds to mice restrained in a double-chambered plethysmograph where respiratory reflexes were monitored. TRPV1 knockouts showed deficiencies in the detection of benzaldehyde, cyclohexanone and eugenol in at least one assay. However, cyclohexanone was the only substance tested that appears to act solely through TRPV1.

  2. A cross-cultural perspective on irritable bowel syndrome.

    Science.gov (United States)

    Gerson, Charles D; Gerson, Mary-Joan

    2010-01-01

    Irritable bowel syndrome is a functional gastrointestinal illness, defined by symptoms. Irritable bowel syndrome has been described as a biopsychosocial condition, in which colonic dysfunction is affected by psychological and social factors. As a result of this unusual constellation, irritable bowel syndrome may be subject to cultural variables that differ in different parts of the globe. In this article, we describe some of the ways in which irritable bowel syndrome may be experienced differently, depending on local belief systems, psychological pressures, acceptance or resistance to a mind-body paradigm, and breakdown in support or relationship structure. Examples are given in which irritable bowel syndrome investigators from countries around the world describe various aspects of the syndrome that may affect the illness experience of their patients. We describe our own research studies that have demonstrated possible adverse effects on disease severity from relationship conflict, attribution of symptoms to physical rather than emotional cause, and the belief that irritable bowel syndrome is enduring and mysterious. Also described is our finding that symptom patterns may differ significantly between different geographic locations. Finally, we discuss the importance of "cultural competence" on the part of healthcare professionals in regard to caring for patients of diverse cultural backgrounds. © 2010 Mount Sinai School of Medicine.

  3. Occupational irritant contact dermatitis due to petroleum naphtha

    OpenAIRE

    Aslı Aytekin; Arzu Karataş Toğral

    2014-01-01

    Irritant contact dermatitis (ICD) is responsible for the vast majority of occupational contact dermatitis and usually seen in professional groups working with wet hand. However, today, with the increasing business lines, employees are exposed to a variety of irritants. Occupational exposure to many chemicals and toxic irritants affect not only the skin, but also the other systems. Therefore, this situation resulting with loss of work and changes in business may become a public health problem....

  4. Tissue Friendly Pendulum: Soft Liner to prevent Tissue Irritation

    Directory of Open Access Journals (Sweden)

    Siddharth Shashidhar Revankar

    2014-01-01

    Full Text Available Palatal mucosal irritation is commonly encountered with the Pendulum appliance. The efficiency of soft liners in reducing tissue irritation has been well documented in the field of prosthodontics. The following article describes an innovative technique where soft liner can be used to reduce palatal mucosal irritation caused by pendulum appliance.

  5. Human volunteer study with PGME: Eye irritation during vapour exposure

    NARCIS (Netherlands)

    Emmen, H.H.; Muijser, H.; Arts, J.H.E.; Prinsen, M.K.

    2003-01-01

    The objective of this study was to establish the possible occurrence of eye irritation and subjective symptoms in human volunteers exposed to propylene glycol monomethyl ether (PGME) vapour at concentrations of 0, 100 and 150 ppm. Testing was conducted in 12 healthy male volunteers using a repeated

  6. Carcinogenesis after sublethal ionizing irradiation and regular avoidance irritation

    International Nuclear Information System (INIS)

    Kalisnik, M.; Vraspir-Porenta, O.; Logonder-Mlinsek, M.; Zorc-Pleskovic, R.; Pajer, Z.; Kham-Lindtner, T.; Zorc, M.; Skrk, J.

    1982-01-01

    160 mice of the BALB/C strain of both sexes, aged 3 months, were divided into four equal groups of which two were regularly irritated by a combination of an optical signal and electrical stroke. After one month of irritation one nonirritated and one irritated group were whole body irradiated with an acute dose of 6.65 Gy (1.83 Gy/min), the other two groups were sham irradiated. The mice lived until spontaneous death or one year after irradiation, when the rest of the animals were sacrificed. Malignant tumors were recorded. Irradiation shortened the survival time while the irritation had an appeasing, compensatory effect, more marked in the males than in the females. After irradiation the number and assortment of the tumors increased and the latent period was significantly shorter. In the irritated animals the number and assortment of the malignant tumors were reduced and the latent time period tended to be longer. These differences, however, were not statistically significant. In spite of some differences the response of both sexes to irradiation and irritation or their combination was similar. (author)

  7. Classification of sensitizing and irritative potential in a combined in-vitro assay

    International Nuclear Information System (INIS)

    Wanner, Reinhard; Sonnenburg, Anna; Quatchadze, Maria; Schreiner, Maximilian; Peiser, Matthias; Zuberbier, Torsten; Stahlmann, Ralf

    2010-01-01

    We have developed a coculture system which in parallel indicates the sensitizing and irritative potential of xenobiotics. The assay is named loose-fit coculture-based sensitization assay (LCSA) and may be performed within 5 days. The system is composed of human monocytes that differentiate to a kind of dendritic cells by 2-day culturing in the presence of allogenic keratinocytes. The culture medium is enriched by a cocktail of recombinant cytokines. On day 3, concentration series of probes are added. On day 5, cells are harvested and analyzed for expression range of CD86 as a marker of sensitizing potential and for uptake of the viability stain 7-AAD as a marker of irritative potential. Estimation of the concentration required to cause a half-maximal increase in CD86 expression allowed quantification of sensitizing potential, and estimation of the concentration required to reduce viability to 50% allowed quantification of irritative potential. Examination of substances with known potential resulted in categorization of test scores. To evaluate our data, we have compared results with those of the validated animal-based sensitization test, the murine local lymph node assay (LLNA, OECD TG 429). To a large extent, results from LCSA and from LLNA achieved analogous grouping of allergens into categories like weak-moderate-strong. However, the new assay showed an improved capacity to distinguish sensitizers from non-sensitizers and irritants. In conclusion, the LCSA contains potential to fulfil the requirements of the EU's programme for the safety of chemicals 'Registration, Evaluation, Authorisation and Restriction of chemical substances' (REACH, 2006) to replace animal models.

  8. Emulsifiers' composition modulates venous irritation of the nanoemulsions as a lipophilic and venous irritant drug delivery system.

    Science.gov (United States)

    Mao, Chengwen; Wan, Jiangling; Chen, Huabing; Xu, Huibi; Yang, Xiangliang

    2009-01-01

    In this study, a nanoemulsion (NE) system was investigated for intravenous delivery of lipophilic and venous irritant drugs. NEs were prepared to deliver diallyl trisulfide (DT) for systemic therapy of bacterial and fungal infection, egg phospholipid was chosen as the main emulsifier, and two co-emulsifiers were also incorporated, including Poloxamer 188 (P188) and Solutol HS 15 (S15). Soybean oil was used as the dispersed phases, forming stable DT NEs with small particle sizes. The venous irritation of DT NEs was evaluated by in vitro human umbilical cord endothelial cells (CRL 1730) compatibility model with the intracellular adenosine triphosphate (ATP) and guanosine triphosphate (GTP) concentrations as the indices. The intracellular ATP and GTP reduction changed with the incorporation of a variety of co-emulsifiers, which varied in a free DT concentration-dependent manner. It was deduced that the free DT concentrations of NEs containing co-emulsifiers were determined by the partition coefficient of DT between oil and surfactant buffer solution. In conclusion, NE was an appropriate delivery system for lipophilic and venous irritant drug, and optimization of the composition of emulsifiers was an effective method to alleviate the venous irritation of DT NEs.

  9. The impact of intolerance of uncertainty, worry and irritability on quality of life in persons with epilepsy: irritability as mediator.

    Science.gov (United States)

    Barahmand, Usha; Haji, Afsar

    2014-10-01

    Epilepsy is a neurological disorder afflicting many people in the world. The impact of epilepsy on the quality of life of those afflicted with epilepsy is greater than the limitations imposed by the seizures alone. Among the several psychological disorders found to be comorbid with epilepsy are anxiety and depression, both of which impair quality of life in epilepsy. Some studies have reported that the anxiety seen in epilepsy is characterized by worry while the depression seen is characterized by irritability. A concept common to both anxiety and depression is intolerance of uncertainty. Therefore, the study explores the relationship between intolerance of uncertainty, worry and irritability and their association to quality of life in epilepsy. A descriptive-correlational research method was used and the research sample comprised 60 consecutive referrals seeking outpatient neurological services for epilepsy at Alavi Hospital in Ardebil. Data were collected by administering the Penn State Worry Questionnaire, Intolerance of Uncertainty Scale, Irritability Questionnaire and Quality of Life in Epilepsy Inventory. Data were analyzed using Pearson's correlation coefficients and multivariate regression analysis. Mediation and moderation analyses were conducted. Findings indicated that intolerance of uncertainty, worry and irritability have unique significant effects on quality of life. The implications are that interventions aimed at improving the quality of life of patients with epilepsy should address their feelings of uncertainty, worry and irritability. Furthermore, irritability seems to mediate the impact of both intolerance of uncertainty and worry on quality of life of individuals with epilepsy. No significant moderation effects were noted. Results underscore the important role of irritability in the quality of life of persons with epilepsy. The findings are discussed with reference to the possibility of particular predisposing temperaments and add credence to

  10. Improving Conductivity Image Quality Using Block Matrix-based Multiple Regularization (BMMR Technique in EIT: A Simulation Study

    Directory of Open Access Journals (Sweden)

    Tushar Kanti Bera

    2011-06-01

    Full Text Available A Block Matrix based Multiple Regularization (BMMR technique is proposed for improving conductivity image quality in EIT. The response matrix (JTJ has been partitioned into several sub-block matrices and the highest eigenvalue of each sub-block matrices has been chosen as regularization parameter for the nodes contained by that sub-block. Simulated boundary data are generated for circular domain with circular inhomogeneity and the conductivity images are reconstructed in a Model Based Iterative Image Reconstruction (MoBIIR algorithm. Conductivity images are reconstructed with BMMR technique and the results are compared with the Single-step Tikhonov Regularization (STR and modified Levenberg-Marquardt Regularization (LMR methods. It is observed that the BMMR technique reduces the projection error and solution error and improves the conductivity reconstruction in EIT. Result show that the BMMR method also improves the image contrast and inhomogeneity conductivity profile and hence the reconstructed image quality is enhanced. ;doi:10.5617/jeb.170 J Electr Bioimp, vol. 2, pp. 33-47, 2011

  11. From topical antidote against skin irritants to a novel counter-irritating and anti-inflammatory peptide

    International Nuclear Information System (INIS)

    Brodsky, Berta; Erlanger-Rosengarten, Avigail; Proscura, Elena; Shapira, Elena; Wormser, Uri

    2008-01-01

    The primary purpose of the present study was to investigate the mechanism of the counter-irritating activity of topical iodine against skin lesions induced by chemical and thermal stimuli. The hypothesis that iodine exerts its activity by inducing an endogenous anti-inflammatory factor was confirmed by exposing guinea pig skin to heat stimulus followed by topical iodine treatment and skin extraction. Injection of the extract into naive guinea pigs reduced heat-induced irritation by 69%. The protective factor, identified as a new nonapeptide (histone H2A 36-44, H-Lys-Gly-Asn-Tyr-Ala-Glu-Arg-Ileu-Ala-OH), caused reduction of 40% in irritation score in heat-exposed guinea pigs. The murine analog (H-Lys-Gly-His-Tyr-Ala-Glu-Arg-Val-Gly-OH, termed IIIM1) reduced sulfur mustard (SM)-induced ear swelling at a dose-dependent bell-shape manner reaching peak activity of 1 mg/kg. Cultured keratinocytes transfected with the peptide were more resistant towards SM than the control cells. The peptide suppressed oxidative burst in activated neutrophils in a concentration-dependent manner. In addition, the peptide reduced glucose oxidase-induced skin edema in mice at a dose-dependent bell-shape manner. Apart from thermal and chemical-induced skin irritation this novel peptide might be of potential use in chronic dermal disorders such as psoriasis and pemphigus as well as non-dermal inflammatory diseases like multiple sclerosis, arthritis and colitis

  12. The irritancy of metalworking fluids: a laser Doppler flowmetry study

    NARCIS (Netherlands)

    de Boer, E. M.; Scholten, R. J.; van Ketel, W. G.; Bruynzeel, D. P.

    1990-01-01

    Irritant contact dermatitis is common in metalworkers exposed to metalworking fluids (MWF). The irritancy of 3 commercially available water-based cutting fluids in maximal user's concentration and 2 neat oils was investigated in 23 healthy volunteers. Additionally, the irritancy of some groups of

  13. Irritable bowel syndrome, the microbiota and the gut-brain axis

    DEFF Research Database (Denmark)

    Raskov, Hans; Burcharth, Jakob; Pommergaard, Hans-Christian

    2016-01-01

    Irritable bowel syndrome is a common functional gastrointestinal disorder and it is now evident that irritable bowel syndrome is a multi-factorial complex of changes in microbiota and immunology. The bidirectional neurohumoral integrated communication between the microbiota and the autonomous...... nervous system is called the gut-brain-axis, which integrates brain and GI functions, such as gut motility, appetite and weight. The gut-brain-axis has a central function in the perpetuation of irritable bowel syndrome and the microbiota plays a critical role. The purpose of this article is to review...... recent research concerning the epidemiology of irritable bowel syndrome, influence of microbiota, probiota, gut-brain-axis, and possible treatment modalities on irritable bowel syndrome....

  14. Reconstruction of the solar EUV irradiance from 1996 to 2010 based on SOHO/EIT images

    Directory of Open Access Journals (Sweden)

    Haberreiter Margit

    2014-01-01

    Full Text Available The solar Extreme UltraViolet (EUV spectrum has important effects on the Earth’s upper atmosphere. For a detailed investigation of these effects it is important to have a consistent data series of the EUV spectral irradiance available. We present a reconstruction of the solar EUV irradiance based on SOHO/EIT images, along with synthetic spectra calculated using different coronal features which represent the brightness variation of the solar atmosphere. The EIT images are segmented with the SPoCA2 tool which separates the features based on a fixed brightness classification scheme. With the SOLMOD code we then calculate intensity spectra for the 10–100 nm wavelength range and each of the coronal features. Weighting the intensity spectra with the area covered by each of the features yields the temporal variation of the EUV spectrum. The reconstructed spectrum is then validated against the spectral irradiance as observed with SOHO/SEM. Our approach leads to good agreement between the reconstructed and the observed spectral irradiance. This study is an important step toward understanding variations in the solar EUV spectrum and ultimately its effect on the Earth’s upper atmosphere.

  15. Antipruritic Effect of Cold-induced and Transient Receptor Potential-agonist-induced Counter-irritation on Histaminergic Itch in Humans.

    Science.gov (United States)

    Andersen, Hjalte H; Melholt, Camilla; Hilborg, Sigurd D; Jerwiarz, Anne; Randers, Amalie; Simoni, Amalie; Elberling, Jesper; Arendt-Nielsen, Lars

    2017-01-04

    A frequent empirical observation is that cold-induced counter-irritation may attenuate itch. The aim of this randomized, single-blinded, exploratory study was to evaluate the counter-irritation effects of cold-stimulation and topical application of transient receptor potential TRPA1/M8-agonists (trans-cinnamaldehyde/L-menthol, respectively), on histamine-induced itch, wheals and neurogenic inflammation in 13 healthy volunteers. Histamine 1% was applied to the volar forearms using skin prick-test lancets. Recorded outcome-parameters were itch intensity, wheal reactions, and neurogenic inflammation (measured by laser-speckle perfusion-imaging). Homotopic thermal counter-irritation was performed with 6 temperatures, ranging from 4°C to 37°C, using a 3 × 3-cm thermal stimulator. Chemical "cold-like" counter-irritation was conducted with 40% L-menthol and 10% trans-cinnamaldehyde, while 5% doxepin was used as a positive antipruritic control/comparator. Cold counter-irritation stimuli from 4°C to 22°C inhibited itch in a stimulus-intensity-dependent manner (p cold-like" counter-irritation with both L-menthol and trans-cinnamaldehyde had antipruritic efficacy similar to doxepin (p Cold-induced counter-irritation had an inhibitory effect on histaminergic itch, suggesting that agonists of cold transduction receptors could be of potential antipruritic value.

  16. Adverse reactions to cosmetics and methods of testing.

    Science.gov (United States)

    Nigam, P K

    2009-01-01

    Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test), eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test), mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test), and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test). Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  17. Laboratory evaluation of the irritancy of bendiocarb, lambda-cyhalothrin and DDT to Anopheles gambiae.

    Science.gov (United States)

    Evans, R G

    1993-09-01

    In a laboratory study, the irritancy of bendiocarb, lambda-cyhalothrin and DDT to Anopheles gambiae was evaluated at field, 1/3 field and 1/10 field rates using WHO conical exposure chambers and excito-repellency test boxes. Bendiocarb was the least irritant insecticide at all rates, inducing levels of takeoff, flight and exiting behavior similar to those of a distilled water control treatment. Of those mosquitoes introduced to the bendiocarb-treated boxes, not more than 1% exited and survived at any dose rate. Lambda-cyhalothrin and DDT were highly irritant to An. gambiae, inducing a strong stimulation to take off and fly and also a high level of exiting. Exiting-survival rates associated with lambda-cyhalothrin and DDT were between 15 and 51%. The relevance of these findings to the control of mosquito populations and the prevention of malaria transmission is discussed.

  18. The Relationship between Irritable Bowel Syndrome, Depression, Anxiety, and Stress among Sample of Irritable Bowel Patients - Predictive Study

    OpenAIRE

    Osama Hasan Gaber

    2016-01-01

    This study aimed to examine the relationship of irritable bowel syndrome, anxiety, depression and stress among a sample of78 IBS patients (Rome III Diagnostic Criteria for Irritable Bowel Syndrome), anxiety symptoms scale, Depression symptoms scale, and stress scale (prepared by the researcher) were used Pearson Correlation Coefficient showed that there are statistically significant relationship between IBS and Anxiety, Depression and Stress (P?=0.01). The Regression and Prediction Coefficien...

  19. Work-associated irritable larynx syndrome.

    Science.gov (United States)

    Anderson, Jennifer A

    2015-04-01

    The purpose of this study is to review the relevant literature concerning work-associated irritable larynx syndrome (WILS), a hyperkinetic laryngeal disorder associated with occupational irritant exposure. Clinical symptoms are variable and include dysphonia, cough, dyspnoea and globus pharyngeus. WILS is a clinical diagnosis and can be difficult to differentiate from asthma. Treatment options for WILS include medical and behavioural therapy. Laryngeal-centred upper airway symptoms secondary to airborne irritants have been documented in the literature under a variety of diagnostic labels, including WILS, vocal cord dysfunction (VCD), laryngeal hypersensitivity and laryngeal neuropathy and many others. The underlying pathophysiology is as yet poorly understood; however, the clinical scenario suggests a multifactorial nature to the disorder. More recent literature indicates that central neuronal plasticity, inflammatory processes and psychological factors are all likely contributors. Possible mechanisms for WILS include central neuronal network plasticity after noxious exposure and/or viral infection, inflammation (i.e. reflux disease) and intrinsic patient factors such a psychological state. Treatment is individualized and frequently includes one or more of the following: environmental changes in the workplace, GERD therapy, behavioural/speech therapy, psychotherapy counselling and neural modifiers.

  20. Identification of cornifelin and early growth response-1 gene as novel biomarkers for in vitro eye irritation using a 3D reconstructed human cornea model MCTT HCE™.

    Science.gov (United States)

    Choi, Seunghye; Lee, Miri; Lee, Su-Hyon; Jung, Haeng-Sun; Kim, Seol-Yeong; Chung, Tae-Young; Choe, Tae-boo; Chun, Young-Jin; Lim, Kyung-Min

    2015-09-01

    Evaluation of the eye irritation is essential in the development of new cosmetic products. Draize rabbit eye irritation test has been widely used in which chemicals are directly applied to rabbit eye, and the symptoms and signs of eyes are scored. However, due to the invasive procedure, it causes substantial pain and discomfort to animals. Recently, we reported in vitro eye irritation test method using a 3D human corneal epithelial model (MCTT HCE™) which is reconstructed from remaining human tissues after a corneal transplantation. This model exhibited an excellent predictive capacity for 25 reference chemicals (sensitivity 100%, specificity 77% and accuracy 88% vs. GHS). To improve the test performance, we explored new biomarkers for the eye irritation through transcriptomic approach. Three surfactants were selected as model eye irritants that include sodium lauryl sulfate, benzalkonium chloride and triton X-100. After test chemicals were treated, we investigated differentially expressed genes through a whole-gene microarray (Affymetrix GeneChip(®) Human Gene 2.0 ST Array, 48,000 probes). As a result, we identified that mRNAs of cornifelin (CNFN), a constituent of the insoluble cornified cell envelope of stratified squamous epithelia, and early growth response-1 (EGR1), a nuclear transcriptional regulator, were significantly up-regulated by all three irritants. Up-regulation of CNFN and EGR1 was further confirmed by Q-RT-PCR, and immunohistochemistry revealed increased level of CNFN in irritant-treated tissues, supporting the relevance of CNFN and EGR1 as new biomarkers for eye irritation.

  1. Altered gastric emptying in patients with irritable bowel syndrome

    International Nuclear Information System (INIS)

    Caballero-Plasencia, A.M.; Valenzuela-Barranco, M.; Herrerias-Gutierrez, J.M.; Esteban-Carretero, J.M.

    1999-01-01

    Irritable bowel syndrome is the most frequent functional disorder of the digestive system. Patients with irritable bowel syndrome have motor disorders not only in the colon, but also in other parts of the digestive tract such as the oesophagus and small intestine; however, it is not known whether the stomach is also involved. We used a radiolabelled mixed solid-liquid meal (technetium-99m for the solid component, indium-111 for the liquid component) to study gastric emptying of solids (GES), liquids (GEL) and indigestible solids (GER) in 50 patients diagnosed as having irritable bowel syndrome (30 with predominant constipation and 20 with predominant diarrhoea). GER was measured by counting the number of indigestible solids remaining in the stomach 4 h after they were swallowed. In patients with irritable bowel syndrome, GES and GEL were slower than in control subjects (P<0.05). GER was normal in all patients except for two women. Thirty-two patients (64%) showed delayed GES, 29 (58%) delayed GEL, and 2 (4%) delayed GER. Among patients with irritable bowel syndrome, GES was slower in those with predominant constipation than in those with predominant diarrhoea (P<0.05); GEL and GER were similar in both groups. Gastroparesis was found in a large proportion of patients with irritable bowel syndrome, suggesting the presence of a more generalised motor disorder of the gut. (orig.)

  2. Evaluation of human skin tests for potential dermal irritant and contact sensitizing products: a position paper

    NARCIS (Netherlands)

    Loveren H van; Jong WH de; Garssen J; LPI

    1998-01-01

    Prediction of human cutaneous irritation and sensitization in view of hazard identification has primarily relied on the use of laboratory animals. Such studies in laboratory animals have been very instrumental in the detection of potential contact sensitizing agents. There are however many

  3. Are patient specific meshes required for EIT head imaging?

    Science.gov (United States)

    Jehl, Markus; Aristovich, Kirill; Faulkner, Mayo; Holder, David

    2016-06-01

    Head imaging with electrical impedance tomography (EIT) is usually done with time-differential measurements, to reduce time-invariant modelling errors. Previous research suggested that more accurate head models improved image quality, but no thorough analysis has been done on the required accuracy. We propose a novel pipeline for creation of precise head meshes from magnetic resonance imaging and computed tomography scans, which was applied to four different heads. Voltages were simulated on all four heads for perturbations of different magnitude, haemorrhage and ischaemia, in five different positions and for three levels of instrumentation noise. Statistical analysis showed that reconstructions on the correct mesh were on average 25% better than on the other meshes. However, the stroke detection rates were not improved. We conclude that a generic head mesh is sufficient for monitoring patients for secondary strokes following head trauma.

  4. Microscopic colitis and small intestinal bacterial overgrowth--diagnosis behind the irritable bowel syndrome?

    Science.gov (United States)

    Stoicescu, Adriana; Andrei, M; Becheanu, G; Stoicescu, M; Nicolaie, T; Diculescu, M

    2012-01-01

    Some patients previously diagnosed with irritable bowel syndrome (IBS) may develop microscopic colitis or small intestinal bacterial overgrowth (SIBO). To estimate the prevalence of microscopic colitis and SIBO in patients with IBS, to evaluate the symptoms and the efficacy of treatment. We examined patients with IBS admitted in our clinic during a three-year period. We identified patients with microscopic colitis by performing total colonoscopy with multiple biopsies from normal intestinal mucosa and those with SIBO by performing a H2-breath test with glucose. We compared the symptoms and the effectiveness of the treatment. Out of the 132 patients initially diagnosed with IBS 3% (n=4) had microscopic colitis and 43.9% (n=58) had SIBO. Diarrhea was the main symptom in patients with microscopic colitis and SIBO (p=0.041), while abdominal pain, abdominal bloating and flatulence were prominent in IBS patients (p=0.042; p=0.039; p=0.048). Specific treatment with rifaximin in SIBO patients negativated H2-breath test in 70.9% cases. Patients suspected to have irritable bowel syndrome should be evaluated for microscopic colitis and SIBO. The proper diagnosis and the specific treatment may cure some difficult cases of the so called "irritable bowel syndrome".

  5. Adverse reactions to cosmetics and methods of testing

    Directory of Open Access Journals (Sweden)

    Nigam P

    2009-01-01

    Full Text Available Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test, eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test, mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test, and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test. Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  6. Potential allergy and irritation incidents among health care workers.

    Science.gov (United States)

    Alamgir, Hasanat; Yu, Shicheng; Chavoshi, Negar; Ngan, Karen

    2008-07-01

    This study describes the types, causes, and outcomes of potential irritation and allergy incidents among workers in British Columbia's health care industry. Data on occupation-induced allergy and irritation incidents were extracted from a standardized database using the number of productive hours obtained from payroll data as a denominator during a 1-year period from three British Columbia health regions. Younger workers, female workers, facility support service workers, laboratory assistants and technicians, and maintenance and acute care workers were found to be at higher risk for allergy and irritation incidents. Major causes of allergy and irritation incidents included chemicals, blood and body fluids, food and objects, communicable diseases, air quality, and latex. A larger proportion of chemically induced incidents resulted in first aid care only, whereas non-chemical incidents required more emergency room visits.

  7. Structural-functional lung imaging using a combined CT-EIT and a Discrete Cosine Transformation reconstruction method.

    Science.gov (United States)

    Schullcke, Benjamin; Gong, Bo; Krueger-Ziolek, Sabine; Soleimani, Manuchehr; Mueller-Lisse, Ullrich; Moeller, Knut

    2016-05-16

    Lung EIT is a functional imaging method that utilizes electrical currents to reconstruct images of conductivity changes inside the thorax. This technique is radiation free and applicable at the bedside, but lacks of spatial resolution compared to morphological imaging methods such as X-ray computed tomography (CT). In this article we describe an approach for EIT image reconstruction using morphologic information obtained from other structural imaging modalities. This leads to recon- structed images of lung ventilation that can easily be superimposed with structural CT or MRI images, which facilitates image interpretation. The approach is based on a Discrete Cosine Transformation (DCT) of an image of the considered transversal thorax slice. The use of DCT enables reduction of the dimensionality of the reconstruction and ensures that only conductivity changes of the lungs are reconstructed and displayed. The DCT based approach is well suited to fuse morphological image information with functional lung imaging at low computational costs. Results on simulated data indicate that this approach preserves the morphological structures of the lungs and avoids blurring of the solution. Images from patient measurements reveal the capabilities of the method and demonstrate benefits in possible applications.

  8. Respiratory irritation associated with inhalation of boron trifluoride and fluorosulfonic acid

    NARCIS (Netherlands)

    Rusch, G.M.; Bowden, A.M.; Muijser, H.; Arts, J.

    2008-01-01

    The objectives of this study were to examine the respiratory irritancy of boron trifluoride (BF3) and fluorosulfonic acid (FSA) following acute inhalation exposure. Testing was conducted using groups of 10 male and 10 female rats (BF3) or groups of 6 male rats (FSA). Rats were exposed for a single

  9. EIT Observations of Coronal Mass Ejections

    Science.gov (United States)

    Gurman, J. B.; Fisher, Richard B. (Technical Monitor)

    2000-01-01

    Before the Solar and Heliospheric Observatory (SOHO), we had only the sketchiest of clues as to the nature and topology of coronal mass ejections (CMEs) below 1.1 - 1.2 solar radii. Occasionally, dimmings (or 'transient coronal holes') were observed in time series of soft X-ray images, but they were far less frequent than CME's. Simply by imaging the Sun frequently and continually at temperatures of 0.9 - 2.5 MK we have stumbled upon a zoo of CME phenomena in this previously obscured volume of the corona: (1) waves, (2) dimmings, and (3) a great variety of ejecta. In the three and a half years since our first observations of coronal waves associated with CME's, combined Large Angle Spectroscopic Coronagraph (LASCO) and extreme ultra-violet imaging telescope (EIT) synoptic observations have become a standard prediction tool for space weather forecasters, but our progress in actually understanding the CME phenomenon in the low corona has been somewhat slower. I will summarize the observations of waves, hot (> 0.9 MK) and cool ejecta, and some of the interpretations advanced to date. I will try to identify those phenomena, analysis of which could most benefit from the spectroscopic information available from ultraviolet coronograph spectrometer (UVCS) observations.

  10. An experimental clinical evaluation of EIT imaging with ℓ1 data and image norms.

    Science.gov (United States)

    Mamatjan, Yasin; Borsic, Andrea; Gürsoy, Doga; Adler, Andy

    2013-09-01

    Electrical impedance tomography (EIT) produces an image of internal conductivity distributions in a body from current injection and electrical measurements at surface electrodes. Typically, image reconstruction is formulated using regularized schemes in which ℓ2-norms are used for both data misfit and image prior terms. Such a formulation is computationally convenient, but favours smooth conductivity solutions and is sensitive to outliers. Recent studies highlighted the potential of ℓ1-norm and provided the mathematical basis to improve image quality and robustness of the images to data outliers. In this paper, we (i) extended a primal-dual interior point method (PDIPM) algorithm to 2.5D EIT image reconstruction to solve ℓ1 and mixed ℓ1/ℓ2 formulations efficiently, (ii) evaluated the formulation on clinical and experimental data, and (iii) developed a practical strategy to select hyperparameters using the L-curve which requires minimum user-dependence. The PDIPM algorithm was evaluated using clinical and experimental scenarios on human lung and dog breathing with known electrode errors, which requires a rigorous regularization and causes the failure of reconstruction with an ℓ2-norm solution. The results showed that an ℓ1 solution is not only more robust to unavoidable measurement errors in a clinical setting, but it also provides high contrast resolution on organ boundaries.

  11. Reproducibility of the chamber scarification test

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner

    1996-01-01

    The chamber scarification test is a predictive human skin irritation test developed to rank the irritation potential of products and ingredients meant for repeated use on normal and diseased skin. 12 products or ingredients can be tested simultaneously on the forearm skin of each volunteer....... The test combines with the procedure scratching of the skin at each test site and subsequent closed patch tests with the products, repeated daily for 3 days. The test is performed on groups of human volunteers: a skin irritant substance or products is included in each test as a positive control...... high reproducibility of the test. Further, intra-individual variation in skin reaction to the 2 control products in 26 volunteers, who participated 2x, is shown, which supports the conclusion that the chamber scarification test is a useful short-term human skin irritation test with high reproducibility....

  12. Altered gastric emptying in patients with irritable bowel syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Caballero-Plasencia, A.M.; Valenzuela-Barranco, M. [Department of Medicine, School of Medicine, University of Granada (Spain); Herrerias-Gutierrez, J.M. [Division of Gastroenterology, University Hospital ``Virgen de la Macarena``, Sevilla (Spain); Esteban-Carretero, J.M. [Central Service of Investigation in Health Sciences, University of Cadiz, Cadiz (Spain)

    1999-04-29

    Irritable bowel syndrome is the most frequent functional disorder of the digestive system. Patients with irritable bowel syndrome have motor disorders not only in the colon, but also in other parts of the digestive tract such as the oesophagus and small intestine; however, it is not known whether the stomach is also involved. We used a radiolabelled mixed solid-liquid meal (technetium-99m for the solid component, indium-111 for the liquid component) to study gastric emptying of solids (GES), liquids (GEL) and indigestible solids (GER) in 50 patients diagnosed as having irritable bowel syndrome (30 with predominant constipation and 20 with predominant diarrhoea). GER was measured by counting the number of indigestible solids remaining in the stomach 4 h after they were swallowed. In patients with irritable bowel syndrome, GES and GEL were slower than in control subjects (P<0.05). GER was normal in all patients except for two women. Thirty-two patients (64%) showed delayed GES, 29 (58%) delayed GEL, and 2 (4%) delayed GER. Among patients with irritable bowel syndrome, GES was slower in those with predominant constipation than in those with predominant diarrhoea (P<0.05); GEL and GER were similar in both groups. Gastroparesis was found in a large proportion of patients with irritable bowel syndrome, suggesting the presence of a more generalised motor disorder of the gut. (orig.) With 1 fig., 3 tabs., 48 refs.

  13. Patients' experiences of healthcare encounters in severe irritable bowel syndrome: an analysis based on narrative and feminist theory.

    Science.gov (United States)

    Björkman, Ida; Simrén, Magnus; Ringström, Gisela; Jakobsson Ung, Eva

    2016-10-01

    This study aimed to explore patients' experiences of healthcare encounters in severe irritable bowel syndrome. Irritable bowel syndrome is a common functional disorder with symptoms such as abdominal pain and disturbed bowel habits, the cause of which is not completely known. Treatments options are limited, and healthcare encounters in irritable bowel syndrome have been described as unsatisfying and frustrating for both patients and professional healthcare providers. Furthermore, the influence of power on healthcare encounters has long been recognised, especially regarding the disadvantaged position of those suffering from functional illness which cannot be identified by commonly used tests or investigations. We interviewed 10 patients during 2014, all attending an outpatient clinic and suffering from severe irritable bowel syndrome. Relying on narrative and feminist theory, we explored how they actively negotiate professional discourse communicated to them in the clinical encounter. The patients' experiences of healthcare encounters in irritable bowel syndrome were mostly described as negative, and often induced feelings of confusion and self-doubt. Positive encounters were described as being listened to, believed and taken seriously. Narrators found it especially problematic when healthcare professionals described irritable bowel syndrome as a minor disorder with primarily stress or psychological aetiology and put the responsibility for recovery onto the patient. Patients' actively negotiated such professional discourse by presenting a counternarrative describing their own suffering and strengths, experienced healthcare shortcomings and possible organic aetiology of irritable bowel syndrome. Patients suffering from severe irritable bowel syndrome described how they often felt a need to protect their positive identities in the face of trivialisation and disbelief by healthcare professionals. A deepened understanding of patients' experiences of healthcare

  14. Studies on aerosols. XI. Influence of particulate matter on the eye irritation produced by volatile irritants and importance of particle size in connection with atmospheric pollution

    Energy Technology Data Exchange (ETDEWEB)

    Dautrebande, L; Shaver, J; Capps, R

    1951-01-01

    This is a review of smog irritation prevented by water filters which remove > 2-..mu..m particles. Formaldehyde, HNO/sub 3/, H/sub 2/SO/sub 4/ vapors combined plus used oil produced stronger irritation than vapors alone. Vapors produced irritation essentially only at concentrations above 4.2 x 10/sup -3/ mg/liter air of each constituent. Three trained human volunteers were exposed to various aerosols via goggles. Blinking and lacrimation were observed. Reaction varied largely between the 3 and between different exposure periods. NaCl, Si dust, and used oil in combination required a much higher concentration to produce eye irritation than with vapors present. NaCl and Si combined did not irritate; used oil did. Photomicrographs showed small (approx. 0.05 ..mu..m), long-chained (1 to 7 ..mu..m), and aggregated (1 to 10 ..mu..m) particles.

  15. Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging

    International Nuclear Information System (INIS)

    Oh, Tong In; Koo, Hwan; Lee, Kyung Heon; Kim, Sang Min; Woo, Eung Je; Lee, Jeehyun; Kim, Sung Wan; Seo, Jin Keun

    2008-01-01

    Validation and interpretation of reconstructed images using a multi-frequency electrical impedance tomography (mfEIT) requires a conductivity phantom including imaging objects with known complex conductivity (σ + iωε) spectra. We describe imaging experiments using the recently developed mfEIT system called the KHU Mark1 with the frequency range of 10 Hz to 500 kHz. Using a bio-impedance spectroscopy (BIS) system, we first measured complex conductivity spectra of different imaging objects including saline, agar, polyacrylamide, TX151, animal hide gelatin, banana and cucumber. Based on an analysis of how conductivity and permittivity affect measured complex boundary voltages, we suggested a new complex version of a multi-frequency time-difference image reconstruction algorithm. Imaging experiments were conducted to produce time-difference images of the objects at multiple frequencies using the proposed algorithm. Images of a conductor (stainless steel) and an insulator (acrylic plastic) were used to set a common scale bar to display all images. Comparing reconstructed time-difference images at multiple frequencies with measured complex conductivity spectra, we found that they showed an overall similarity in terms of changes in complex conductivity values with respect to frequency. However, primarily due to the limitation of the difference imaging algorithm, we suggest that multi-frequency time-difference images must be interpreted in terms of relative contrast changes with respect to frequency. We propose further imaging studies using biological tissues of known complex conductivity spectra and using human subjects to find clinical applications of the mfEIT system

  16. A 3D finite-difference BiCG iterative solver with the Fourier-Jacobi preconditioner for the anisotropic EIT/EEG forward problem.

    Science.gov (United States)

    Turovets, Sergei; Volkov, Vasily; Zherdetsky, Aleksej; Prakonina, Alena; Malony, Allen D

    2014-01-01

    The Electrical Impedance Tomography (EIT) and electroencephalography (EEG) forward problems in anisotropic inhomogeneous media like the human head belongs to the class of the three-dimensional boundary value problems for elliptic equations with mixed derivatives. We introduce and explore the performance of several new promising numerical techniques, which seem to be more suitable for solving these problems. The proposed numerical schemes combine the fictitious domain approach together with the finite-difference method and the optimally preconditioned Conjugate Gradient- (CG-) type iterative method for treatment of the discrete model. The numerical scheme includes the standard operations of summation and multiplication of sparse matrices and vector, as well as FFT, making it easy to implement and eligible for the effective parallel implementation. Some typical use cases for the EIT/EEG problems are considered demonstrating high efficiency of the proposed numerical technique.

  17. Characteristics of EIT Dimmings in Solar Eruptions

    Science.gov (United States)

    Adams, Mitzi; Sterling, A. C.

    2006-01-01

    Intensity "dimmings" in coronal images are a key feature of solar eruptions. Such dimmings are likely the source locations for much of the material expelled in coronal mass ejections (CMEs). Characteristics such as the timing of the dimmings with respect to the onset of other eruption signatures, and the location of the dimmings in the context of the magnetic field environment of the erupting region, are indicative of the mechanism leading to the eruption. We examine dimmings of six eruptions in images from the EUV Imaging Telescope (EIT) on SOHO, along with supplementary soft X-ray (SXR) data from GOES and the SXR Telescope (SXT) on Yohkoh. We examine the timing of the dimming onset and compare with the time of EUV and SXR brightening and determine the timescale for the recovery from dimming for each event. With line-of-sight photospheric magnetograms from the MDI instrument on SOHO, we determine the magnetic structure of the erupting regions and the locations of the dimmings in those regions. From our analysis we consider which mechanism likely triggered each eruption: internal tether cutting, external tether cutting ("breakout"), loss of equilibrium, or some other mechanism.

  18. In vitro assessment of eye irritancy using the Reconstructed Human Corneal Epithelial SkinEthic HCE model: application to 435 substances from consumer products industry.

    Science.gov (United States)

    Cotovio, José; Grandidier, Marie-Hélène; Lelièvre, Damien; Bremond, Christelle; Amsellem, Carolle; Maloug, Saber; Ovigne, Jean-Marc; Loisel-Joubert, Sophie; Lee, Aline Van Der; Minondo, Anne-Marie; Capallere, Christophe; Bertino, Béatrice; Alépée, Nathalie; Tinois-Tessonneaud, Estelle; de Fraissinette, Anne De Brugerolle; Meunier, Jean-Roch; Leclaire, Jacques

    2010-03-01

    The 7th amendment of the EU Cosmetics Directive led to the ban of eye irritation testing for cosmetic ingredients in animals, effective from March 11th 2009. Over the last 20years, many efforts have been made to find reliable and relevant alternative methods. The SkinEthic HCE model was used to evaluate the in vitro eye irritancy potential of substances from a cosmetic industry portfolio. An optimized protocol based on a specific 1-h treatment and a 16-h post-treatment incubation period was first assessed on a set of 102 substances. The prediction model (PM) based on a 50% viability cut-off, allowed to draw up two classes (Irritants and Non-Irritants), with good associated sensitivity (86.2%) and specificity (83.5%). To check the robustness of the method, the evaluated set was expanded up to 435 substances. Final performances maintained a high level and were characterized by an overall accuracy value > 82% when using EU or GHS classification rules. Results showed that the SkinEthic HCE test method is a promising in vitro tool for the prediction of eye irritancy. Optimization datasets were shared with the COLIPA Eye Irritation Project Team and ECVAM experts, and reviewed as part of an ongoing progression to enter an ECVAM prospective validation study for eye irritation. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  19. Systematic review: Complementary and alternative medicine in the irritable bowel syndrome.

    LENUS (Irish Health Repository)

    Hussain, Z

    2012-02-03

    BACKGROUND: Complementary and alternative medical therapies and practices are widely employed in the treatment of the irritable bowel syndrome. AIM: To review the usage of complementary and alternative medicine in the irritable bowel syndrome, and to assess critically the basis and evidence for its use. METHODS: A systematic review of complementary and alternative medical therapies and practices in the irritable bowel syndrome was performed based on literature obtained through a Medline search. RESULTS: A wide variety of complementary and alternative medical practices and therapies are commonly employed by irritable bowel syndrome patients both in conjunction with and in lieu of conventional therapies. As many of these therapies have not been subjected to controlled clinical trials, some, at least, of their efficacy may reflect the high-placebo response rate that is characteristic of irritable bowel syndrome. Of those that have been subjected to clinical trials most have involved small poor quality studies. There is, however, evidence to support efficacy for hypnotherapy, some forms of herbal therapy and certain probiotics in irritable bowel syndrome. CONCLUSIONS: Doctors caring for irritable bowel syndrome patients need to recognize the near ubiquity of complementary and alternative medical use among this population and the basis for its use. All complementary and alternative medicine is not the same and some, such as hypnotherapy, forms of herbal therapy, specific diets and probiotics, may well have efficacy in irritable bowel syndrome. Above all, we need more science and more controlled studies; the absence of truly randomized placebo-controlled trials for many of these therapies has limited meaningful progress in this area.

  20. Neural Correlates of Irritability in Disruptive Mood Dysregulation and Bipolar Disorders.

    Science.gov (United States)

    Wiggins, Jillian Lee; Brotman, Melissa A; Adleman, Nancy E; Kim, Pilyoung; Oakes, Allison H; Reynolds, Richard C; Chen, Gang; Pine, Daniel S; Leibenluft, Ellen

    2016-07-01

    Bipolar disorder and disruptive mood dysregulation disorder (DMDD) are clinically and pathophysiologically distinct, yet irritability can be a clinical feature of both illnesses. The authors examine whether the neural mechanisms mediating irritability differ between bipolar disorder and DMDD, using a face emotion labeling paradigm because such labeling is deficient in both patient groups. The authors hypothesized that during face emotion labeling, irritability would be associated with dysfunctional activation in the amygdala and other temporal and prefrontal regions in both disorders, but that the nature of these associations would differ between DMDD and bipolar disorder. During functional MRI acquisition, 71 youths (25 with DMDD, 24 with bipolar disorder, and 22 healthy youths) performed a labeling task with happy, fearful, and angry faces of varying emotional intensity. Participants with DMDD and bipolar disorder showed similar levels of irritability and did not differ from each other or from healthy youths in face emotion labeling accuracy. Irritability correlated with amygdala activity across all intensities for all emotions in the DMDD group; such correlation was present in the bipolar disorder group only for fearful faces. In the ventral visual stream, associations between neural activity and irritability were found more consistently in the DMDD group than in the bipolar disorder group, especially in response to ambiguous angry faces. These results suggest diagnostic specificity in the neural correlates of irritability, a symptom of both DMDD and bipolar disorder. Such evidence of distinct neural correlates suggests the need to evaluate different approaches to treating irritability in the two disorders.

  1. Acute irritant reaction to an antiseptic bath emollient

    OpenAIRE

    Saw, N; Hindmarsh, J

    2005-01-01

    Antiseptic bath emollients are commonly prescribed for treatment of eczema and are generally safe for frequent application. Although acute irritant reactions are uncommon it is nevertheless recognised and could have significant morbidity. This case describes a young male patient who developed an acute irritant reaction localised to the external genitalia, mimicking Fournier's gangrene, after overnight application of Oilatum Plus antiseptic bath emollients.

  2. Assessment of the potential skin irritation of lysine-derivative anionic surfactants using mouse fibroblast and human keratinocytes as an alternative to animal testing

    OpenAIRE

    Sánchez Molina, Lourdes; Mitjans Arnal, Montserrat; Infante Martínez-Pardo, Ma. Rosa; Vinardell Martínez-Hidalgo, Ma. Pilar

    2004-01-01

    Purpose. The aim of this study was to identify new surfactants with low skin irritant properties for use in pharmaceutical and cosmetic formulations, employing cell culture as an alternative method to in vivo testing. In addition, we sought to establish whether potential cytotoxic properties were related to the size of the counterions bound to the surfactants. Methods. Cytotoxicity was assessed in the mouse fibroblast cell line 3T6, and the human keratinocyte cell line NCTC 2544, using the MT...

  3. Irritable mood and the Diagnostic and Statistical Manual of Mental Disorders

    Directory of Open Access Journals (Sweden)

    Safer Daniel J

    2009-10-01

    Full Text Available Abstract Background The terms 'irritable mood' and 'irritability' have been applied to describe and define a variety of different categories in the Diagnostic and Statistical Manual of Mental Disorders (DSM. More precise diagnostic terms and concepts are needed. Methods A concise critical historical review of DSM categories characterized by irritability, anger, and aggression is presented followed by recommendations. Results This analysis describes the broad ranging and imprecise use of the term irritability since the first DSM in 1952. A more age-appropriate and functional realignment of psychiatric categories linked to dysfunctional anger is suggested. Among other recommendations, this realignment would remove irritability as a problematic definer in the present DSM mood categories: expand oppositional defiant disorder to include adults; link the callous unemotional subtype of conduct disorder in adolescents to antisocial personality disorder; move intermittent explosive disorder to an appropriate category: and expand the term 'mood' to apply also to dysfunctional anger and anxiety. Conclusion The non-specific term 'irritability' commonly used in the DSM has had an adverse effect on diagnostic specificity and thereby on treatment. Dysfunctional anger is a major mood disorder which merits a more prominent and better defined representation in psychiatric nomenclature.

  4. Methylglyoxal induces systemic symptoms of irritable bowel syndrome.

    Science.gov (United States)

    Zhang, Shuang; Jiao, Taiwei; Chen, Yushuai; Gao, Nan; Zhang, Lili; Jiang, Min

    2014-01-01

    Patients with irritable bowel syndrome (IBS) show a wide range of symptoms including diarrhea, abdominal pain, changes in bowel habits, nausea, vomiting, headache, anxiety, depression and cognitive impairment. Methylglyoxal has been proved to be a potential toxic metabolite produced by intestinal bacteria. The present study was aimed at investigating the correlation between methylglyoxal and irritable bowel syndrome. Rats were treated with an enema infusion of methylglyoxal. Fecal water content, visceral sensitivity, behavioral tests and serum 5-hydroxytryptamine (5-HT) were assessed after methylglyoxal exposure. Our data showed that fecal water content was significantly higher than controls after methylglyoxal exposure except that of 30 mM group. Threshold volumes on balloon distension decreased in the treatment groups. All exposed rats showed obvious head scratching and grooming behavior and a decrease in sucrose preference. The serum 5-HT values were increased in 30, 60, 90 mM groups and decreased in 150 mM group. Our findings suggested that methylglyoxal could induce diarrhea, visceral hypersensitivity, headache as well as depression-like behaviors in rats, and might be the key role in triggering systemic symptoms of IBS.

  5. Acute irritant reaction to an antiseptic bath emollient

    Science.gov (United States)

    Saw, N; Hindmarsh, J

    2005-01-01

    Antiseptic bath emollients are commonly prescribed for treatment of eczema and are generally safe for frequent application. Although acute irritant reactions are uncommon it is nevertheless recognised and could have significant morbidity. This case describes a young male patient who developed an acute irritant reaction localised to the external genitalia, mimicking Fournier's gangrene, after overnight application of Oilatum Plus antiseptic bath emollients. PMID:15701748

  6. IRRITABLE MOOD IN ADULT MAJOR DEPRESSIVE DISORDER: RESULTS FROM THE WORLD MENTAL HEALTH SURVEYS

    Science.gov (United States)

    Kovess-Masfety, Viviane; Alonso, Jordi; Angermeyer, Matthias; Bromet, Evelyn; de Girolamo, Giovanni; de Jonge, Peter; Demyttenaere, Koen; Florescu, Silvia E.; Gruber, Michael J.; Gureje, Oye; Hu, Chiyi; Huang, Yueqin; Karam, Elie G.; Jin, Robert; Lépine, Jean-Pierre; Levinson, Daphna; McLaughlin, Katie A.; Medina-Mora, María E.; O’Neill, Siobhan; Ono, Yutaka; Posada-Villa, José A.; Sampson, Nancy A.; Scott, Kate M.; Shahly, Victoria; Stein, Dan J.; Viana, Maria C.; Zarkov, Zahari; Kessler, Ronald C.

    2014-01-01

    Background Although irritability is a core symptom of DSM-IV major depressive disorder (MDD) for youth but not adults, clinical studies find comparable rates of irritability between nonbipolar depressed adults and youth. Including irritability as a core symptom of adult MDD would allow detection of depression-equivalent syndromes with primary irritability hypothesized to be more common among males than females. We carried out a preliminary examination of this issue using cross-national community-based survey data from 21 countries in the World Mental Health (WMH) Surveys (n = 110,729). Methods The assessment of MDD in the WHO Composite International Diagnostic Interview includes one question about persistent irritability. We examined two expansions of the definition of MDD involving this question: (1) cases with dysphoria and/or anhedonia and exactly four of nine Criterion A symptoms plus irritability; and (2) cases with two or more weeks of irritability plus four or more other Criterion A MDD symptoms in the absence of dysphoria or anhedonia. Results Adding irritability as a tenth Criterion A symptom increased lifetime prevalence by 0.4% (from 11.2 to 11.6%). Adding episodes of persistent irritability increased prevalence by an additional 0.2%. Proportional prevalence increases were significantly higher, but nonetheless small, among males compared to females. Rates of severe role impairment were significantly lower among respondents with this irritable depression who did not meet conventional DSM-IV criteria than those with DSM-IV MDD. Conclusion Although limited by the superficial assessment in this single question on irritability, results do not support expanding adult MDD criteria to include irritable mood. PMID:23364997

  7. Irritant potential of some constituents from oleo-gum-resin of Commiphora myrrha.

    Science.gov (United States)

    Saeed, M Asif; Sabir, A W

    2004-01-01

    The irritant potentials of essential oil and seven sesquiterpenoids compounds newly isolated from the oleo-gum-resin of Commiphora myrrha were investigated by open mouse ear assay. The essential oil, curzerenone, furanodiene-6-one and furanoeudesma-1,3-diene showed potent and persistent irritant effects while others possess least irritant potentials.

  8. Perfusion redistribution after a pulmonary-embolism-like event with contrast enhanced EIT.

    Science.gov (United States)

    Nguyen, D T; Bhaskaran, A; Chik, W; Barry, M A; Pouliopoulos, J; Kosobrodov, R; Jin, C; Oh, T I; Thiagalingam, A; McEwan, A L

    2015-06-01

    Recent studies showed that regional pulmonary perfusion can be reliably estimated using electrical impedance tomography (EIT) with the aid of hypertonic saline based contrast enhancement. Building on these successful studies, we studied contrast EIT for pulmonary perfusion defect caused by an artificially induced pulmonary embolism (PE) in a large ovine model (N = 8, 78 ± 7.8 kg). Furthermore, the efficacy of a less invasive contrast bolus of 0.77 ml kg(-1) of NaCl 3% was compared with a more concentrated bolus of 0.13 ml kg(-1) of NaCl 20%. Prior to the injection of each contrast bolus injection, ventilation was turned off to provide a total of 40 to 45 s of apnoea. Each bolus of impedance contrast was injected through a catheter into the right atrium. Pulmonary embolisation was performed by balloon occlusion of part of the right branch of the pulmonary trunk. Four parameters representing the kinetics of the contrast dilution in the lung were evaluated for statistical differences between baseline and PE, including peak value, maximum uptake, maximum washout and area under the curve of the averaged contrast dilution curve in each lung. Furthermore, the right lung to left lung (R2L) ratio of each the aforementioned parameters were assessed. While all of the R2L ratios yielded significantly different means between baseline and PE, it can be concluded that the R2L ratios of area under the curve and peak value of the averaged contrast dilution curve are the most promising and reliable in assessing PE. It was also found that the efficacy of the two types of impedance contrasts were not significantly different in distinguishing PE from baseline in our model.

  9. Are Histrionic Personality Traits Associated with Irritability during Conscious Sedation Endoscopy?

    OpenAIRE

    Lee, Sang Shin; Kim, Hyung Hun; Park, Hyo Jung

    2015-01-01

    Aim. We aimed to evaluate whether histrionic personality traits are associated with irritability during conscious sedation endoscopy (CSE). Materials and Methods. A prospective cross-sectional study was planned. Irritability during CSE was classified into five grades: 0, no response; I, minimal movement; II, moderate movement; III, severe movement; IV, fighting against procedure. Patients in grades III and IV were defined as the irritable group. Participants were required to complete question...

  10. Developing a quick and inexpensive in vitro (non-animal) bioassay for mascara irritation.

    Science.gov (United States)

    Thomason, H; Montagnes, D J S

    2014-04-01

    Mascara is a mild irritant that causes a range of medical problems. Animal models to predict ocular irritation have, however, been questioned at a number of levels, and there is a continued need to develop in vitro testing methods. We assess changes in an easily quantifiable attribute, ciliated protozoan growth rate, as a sensitive, sublethal measure. Specifically, we test six, randomly chosen, commercial mascara products against a control (as treatments) and reveal through ANOVA (n = 6, α = 0.05) significant differences in the specific growth rate to treatments (for both protozoa). We provide evidence that two easily cultured protozoa (Paramecium caudatum, Blepharisma japonicum) should be considered as models to assess ocular irritancy (and possibly cosmetics in general) and establish the groundwork for such studies to be applied at a more commercial level. We do this by developing a bioassay for mascara toxicity and indicate the low cost (after equipment is purchased, on the order of $100s) and the ease of performing such tests (able to be conducted by undergraduate students), as a consideration for their future commercial application. We first examined dose dependence of responses, revealing that there was a need to conduct preliminary work to determine appropriate levels for sublethal responses. We then show that some products resulted in mortality at high concentrations, others decreased growth rate by >50% (compared with the control), whereas others had no significant effect, compared with the control. We have provided a novel, quick and inexpensive means to assess mascara; the next step is to validate these ciliate bioassays by comparison with animal testing and epidemiological studies, which is beyond the scope of this fundamental 'proof-of-concept' study. © 2013 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  11. Evaluation of the contribution of chronic skin irritation and selected compositional parameters to the tumorigenicity of petroleum middle distillates in mouse skin.

    Science.gov (United States)

    Freeman, J J; Federici, T M; McKee, R H

    1993-07-28

    Two-year skin carcinogenicity studies were conducted in C3H mice to assess the effects of irritation and selected compositional parameters on the carcinogenic potential of four petroleum liquids. Three samples (lightly refined paraffinic oil, LRPO; lightly hydrodesulfurized specialty oil, LHSO; jet fuel, JF) can be generically classified as middle distillates, i.e. distillation occurs between 350 and 700 degrees F (175-370 degrees C). The fourth sample was a Steam Cracked Gas Oil (SCGO) that distilled within the same range. In studies that assess the effects of irritation on tumorigenicity, LRPO was tested undiluted or was diluted to 50% and 25% in either mineral oil (which eliminated irritation of the skin) or toluene (which did not). Undiluted LRPO elicited tumors in 8% of the mice. Both dilution procedures eliminated tumorigenic potential. Thus, it was possible to maintain a visible level of skin irritation equivalent to that elicited by undiluted LRPO without inducing tumors. SCGO elicited a chronic irritant state grossly equivalent to LRPO but was not tumorigenic. Jet Fuel A (JF) was tested undiluted using both a standard skin painting protocol and an intermittent dosing schedule in which treatment was suspended periodically to allow skin irritation to resolve. The standard treatment protocol of JF resulted in both marked skin irritation and tumors in 44% of the mice. However, using the intermittent schedule, the tumor yield was reduced to 2%. Collectively these data demonstrate that tumor formation is not a necessary sequelae to chronic skin irritation. Conversely, prevention of a marked chronic irritant state was accompanied by decreased tumor yield. These data suggest that the chronic irritant state may be a necessary but not sufficient condition for tumor formation. In studies to assess the effects of compositional parameters, a lightly hydrodesulfurized specialty oil (LHSO) similar to LRPO but refined to have negligible levels of sulfur compounds (3 ppm

  12. Chemosensory irritations and pulmonary effects of acute exposure to emissions from oriented strand board.

    Science.gov (United States)

    Gminski, Richard; Marutzky, Rainer; Kevekordes, Sebastian; Fuhrmann, Frank; Bürger, Werner; Hauschke, Dieter; Ebner, Winfried; Mersch-Sundermann, Volker

    2011-09-01

    Due to the reduction of air change rates in low-energy houses, the contribution to indoor air quality of volatile organic compounds (VOCs) emitting from oriented strand boards (OSB) has become increasingly important. The aim of this study was to evaluate sensory irritations, pulmonary effects and odor annoyance of emissions from OSB in healthy human volunteers compared to clean air. Twenty-four healthy non-smokers were exposed to clean air and OSB emissions for 2 h under controlled conditions in a 48 m(3) test chamber at three different time points: to fresh OSB panels and to the same panels after open storage for 2 and 8 weeks. Chemosensory irritation, exhaled nitric oxide (NO) concentration, eye blink frequency, lung function and subjective perception of irritation of eyes, nose and throat were examined before, during and after exposure. Additionally, olfactory perception was investigated. Total VOC exposure concentrations reached 8.9 ± 0.8 mg/m(3) for the fresh OSB panels. Emissions consisted predominantly of α-pinene, Δ(3)-carene and hexanal. Two-hour exposure to high VOC concentrations revealed no irritating or pulmonary effects. All the subjective ratings of discomfort were at a low level and the medians did not exceed the expression 'hardly at all.' Only the ratings for smell of emissions increased significantly during exposure in comparison to clean air. In conclusion, exposure of healthy volunteers to OSB emissions did not elicit sensory irritations or pulmonary effects up to a VOC concentration of about 9 mg/m(3). Sensory intensity of OSB emissions in the chamber air was rated as 'neutral to pleasant.'

  13. Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: Consensus statement of the TRanslational EIT developmeNt stuDy group

    NARCIS (Netherlands)

    Frerichs, I. (Inéz); M.B.P. Amato (Marcelo); A.H. van Kaam (Anton); Tingay, D.G. (David G.); Zhao, Z. (Zhanqi); Grychtol, B. (Bartlomiej); Bodenstein, M. (Marc); Gagnon, H. (Hervé); S.H. Bohm; Teschner, E. (Eckhard); O. Stenqvist (Ola); Mauri, T. (Tommaso); Torsani, V. (Vinicius); Camporota, L. (Luigi); Schibler, A. (Andreas); Wolf, G.K. (Gerhard K.); D.A.M.P.J. Gommers (Diederik); S. Leonhardt (Steffen); Adler, A. (Andy); Fan, E. (Eddy); Lionheart, W.R.B. (William R.B.); Riedel, T. (Thomas); Rimensberger, P.C. (Peter C.); Suarez, F. (Fernando); Weiler, S.N. (Sipmann Norbert); H. Wrigge (Hermann)

    2017-01-01

    textabstractElectrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function

  14. Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: Consensus statement of the TRanslational EIT developmeNt stuDy group

    NARCIS (Netherlands)

    Frerichs, I. (Inéz); M.B.P. Amato (Marcelo); A.H. van Kaam (Anton); Tingay, D.G. (David G.); Zhao, Z. (Zhanqi); Grychtol, B. (Bartlomiej); Bodenstein, M. (Marc); Gagnon, H. (Hervé); S.H. Bohm; Teschner, E. (Eckhard); O. Stenqvist (Ola); Mauri, T. (Tommaso); Torsani, V. (Vinicius); Camporota, L. (Luigi); Schibler, A. (Andreas); Wolf, G.K. (Gerhard K.); D.A.M.P.J. Gommers (Diederik); S. Leonhardt (Steffen); Adler, A. (Andy); Fan, E. (Eddy); Lionheart, W.R.B. (William R.B.); Riedel, T. (Thomas); Rimensberger, P.C. (Peter C.); Sipmann, F.S. (Fernando Suarez); Weiler, N. (Norbert); H. Wrigge (Hermann)

    2016-01-01

    textabstractElectrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function

  15. Respon Konsumen pada Mobile Advergames: Intrusiveness dan Irritation

    Directory of Open Access Journals (Sweden)

    Sony Kusumasondjaja

    2016-12-01

    Full Text Available Abstract. Increasing adoption of mobile advergames to deliver marketing messages has not been followed by empirical findings to support its effectiveness. This research attempts to examine the effect of mobile advergames intrusiveness on consumer irritation, attitudes, and purchase intention. This investigation on mobile advergame effectiveness was based on the increasing use of mobile media to deliver marketing messages to consumers from different demographic background. Conceptual framework was developed based on Advertising Avoidance Theory. For data collection, self-administered survey was conducted by adopting purposive sampling involving 213 respondents residing in Surabaya who have had experience in playing mobile game as respondents. Results indicate that intrusiveness positively affects consumer irritation. Consumer irritation negatively affects attitude towards the mobile advergames and attitude towards the advertised product. The better the consumer attitude towards the mobile advergames, the more positive the attitude towards the advertised product. Moreover, the more positive the attitude towards the advertised product, the greater the consumer intention to purchase. Interestingly, consumer attitude toward the mobile advergames has insignificant influence on purchase intention. Findings of the study offer significant contribution to marketing practices using mobile advergames as media placement in their advertising strategy. Keywords: intrusiveness, irritation, mobile advergames, attitude, advertising

  16. The neural substrates of cognitive flexibility are related to individual differences in preschool irritability: A fNIRS investigation

    Directory of Open Access Journals (Sweden)

    Yanwei Li

    2017-06-01

    Full Text Available Preschool (age 3–5 is a phase of rapid development in both cognition and emotion, making this a period in which the neurodevelopment of each domain is particularly sensitive to that of the other. During this period, children rapidly learn how to flexibly shift their attention between competing demands and, at the same time, acquire critical emotion regulation skills to respond to negative affective challenges. The integration of cognitive flexibility and individual differences in irritability may be an important developmental process of early childhood maturation. However, at present it is unclear if they share common neural substrates in early childhood. Our main goal was to examine the neural correlates of cognitive flexibility in preschool children and test for associations with irritability. Forty-six preschool aged children completed a novel, child-appropriate, Stroop task while dorsolateral prefrontal cortex (DLPFC activation was recorded using functional Near Infrared Spectroscopy (fNIRS. Parents rated their child’s irritability. Results indicated that left DLPFC activation was associated with cognitive flexibility and positively correlated with irritability. Right DLPFC activation was also positively correlated with irritability. Results suggest the entwined nature of cognitive and emotional neurodevelopment during a developmental period of rapid and mutual acceleration.

  17. Anti-irritant and anti-inflammatory effects of glycerol and xylitol in sodium lauryl sulphate-induced acute irritation.

    Science.gov (United States)

    Szél, E; Polyánka, H; Szabó, K; Hartmann, P; Degovics, D; Balázs, B; Németh, I B; Korponyai, C; Csányi, E; Kaszaki, J; Dikstein, S; Nagy, K; Kemény, L; Erős, G

    2015-12-01

    Glycerol is known to possess anti-irritant and hydrating properties and previous studies suggested that xylitol may also have similar effects. Our aim was to study whether different concentrations of these polyols restore skin barrier function and soothe inflammation in sodium lauryl sulphate (SLS)-induced acute irritation. The experiments were performed on male SKH-1 hairless mice. The skin of the dorsal region was exposed to SLS (5%) for 3 h alone or together with 5% or 10% of glycerol respectively. Further two groups received xylitol solutions (8.26% and 16.52% respectively) using the same osmolarities, which were equivalent to those of the glycerol treatments. The control group was treated with purified water. Transepidermal water loss (TEWL) and skin hydration were determined. Microcirculatory parameters of inflammation were observed by means of intravital videomicroscopy (IVM). Furthermore, accumulation of neutrophil granulocytes and lymphocytes, the expression of inflammatory cytokines and SLS penetration were assessed, as well. Treatment with the 10% of glycerol and both concentrations of xylitol inhibited the SLS-induced elevation of TEWL and moderated the irritant-induced increase in dermal blood flow and in the number of leucocyte-endothelial interactions. All concentrations of the applied polyols improved hydration and prevented the accumulation of lymphocytes near the treatment site. At the mRNA level, neither glycerol nor xylitol influenced the expression of interleukin-1 alpha. However, expression of interleukin-1 beta was significantly decreased by the 10% glycerol treatment, while expression of tumour necrosis factor-alpha decreased upon the same treatment, as well as in response to xylitol. Higher polyol treatments decreased the SLS penetration to the deeper layers of the stratum corneum. Both of the analysed polyols exert considerable anti-irritant and anti-inflammatory properties, but the effective concentration of xylitol is lower than that of

  18. Building a Definition of Irritability From Academic Definitions and Lay Descriptions.

    Science.gov (United States)

    Barata, Paula C; Holtzman, Susan; Cunningham, Shannon; O'Connor, Brian P; Stewart, Donna E

    2016-04-08

    The current work builds a definition of irritability from both academic definitions and lay perspectives. In Study 1, a quantitative content analysis of academic definitions resulted in eight main content categories (i.e., behaviour, emotion or affect, cognition, physiological, qualifiers, irritant, stability or endurance, and other). In Study 2, a community sample of 39 adults participated in qualitative interviews. A deductive thematic analysis resulted in two main themes. The first main theme dealt with how participants positioned irritability in relation to other negative states. The second dealt with how participants constructed irritability as both a loss of control and as an experience that should be controlled. The discussion integrates the findings of both studies and provides a concise, but comprehensive definition.

  19. Cytological changes and conjunctival hyperemia in relation to sensory eye irritation

    DEFF Research Database (Denmark)

    Hempel-Jørgensen, Anne; Kjærgaard, Søren K.; Mølhave, Lars

    1998-01-01

    irritation and possible physiological/pathological changes in the mucosal membranes in relation to studies of indoor air. Two studies (study 1 and study 2) were conducted to investigate changes in conjunctival hyperemia and conjunctival fluid cytology for subjects exposed to volatile organic compounds (VOCs...... and conjunctival fluid was sampled before and after exposure. Moreover, the perceived irritation intensities were registered continuously during exposure. Overall, perceived irritation intensity and conjunctival hyperemia increased with increasing exposure concentrations, whereas cytological changes...

  20. Effect of allergens and irritants on levels of natural moisturizing factor and corneocyte morphology

    NARCIS (Netherlands)

    Koppes, Sjors A.; Ljubojević Hadžavdić, Suzana; Jakasa, Ivone; Franceschi, Nika; Riethmüller, Christoph; Jurakić Tončic, Ružica; Marinovic, Branka; Raj, Nidhin; Rawlings, Anthony V.; Voegeli, Rainer; Lane, Majella E.; Haftek, Marek; Frings-Dresen, Monique H. W.; Rustemeyer, Thomas; Kezic, Sanja

    2017-01-01

    The irritant sodium lauryl sulfate (SLS) is known to cause a decrease in the stratum corneum level of natural moisturizing factor (NMF), which in itself is associated with changes in corneocyte surface topography. To explore this phenomenon in allergic contact dermatitis. Patch testing was performed

  1. Augmentation of skin response by exposure to a combination of allergens and irritants - a review

    DEFF Research Database (Denmark)

    Pedersen, Line Kynemund; Johansen, Jeanne Duus; Held, Elisabeth

    2004-01-01

    Clinical experimental studies on contact dermatitis (CD) often evaluate the effect of one allergen or one irritant at a time. In real life, the skin is often exposed to more allergens, more irritants or allergens and irritants in combination. This combined exposure may potentially influence irrit...

  2. CME Eruption Onset Observations from EIT and SXT

    Science.gov (United States)

    Sterling, A. C.

    2004-01-01

    Why CMEs erupt is a major outstanding puzzle of solar physics. Signatures observable at the earliest stages of eruption onset may hold precious clues about the onset mechanism. We present observations in EUV from SOHO/EIT and in soft X-rays from Yohkoh/SXT of the re-eruption and eruption phases of CME expulsion, along with the eruption's magnetic setting found from SOHO/MDI magnetograms. Most of our events involve clearly-observable filament eruptions and multiple neutral lines, and we use the magnetic settings and motions of the filaments to help infer the geometry and behavior of the associated erupting magnetic fields. Pre-eruption and early-eruption signatures include a relatively slow filament rise prior to eruption, and intensity "dimmings" and brightenings, both in the immediate neighborhood of the "core" (location of greatest magnetic shear) of the erupting fields and at locations remote from the core. These signatures and their relative timings place observational constraints on eruption mechanisms; our recent work has focused on implications for the so-called "tether cutting" and "breakout" models, but the same observational constraints are applicable to any model.

  3. Irritable Bowel Syndrome in a Population of African Patients

    Directory of Open Access Journals (Sweden)

    Sylvester Chuks Nwokediuko

    2012-01-01

    Full Text Available Background. Functional dyspepsia is the prototype functional gastrointestinal disorder. This study was designed to determine its prevalence, subtypes, and risk factors associated with the subtypes. Method. Patients with upper gastrointestinal symptoms who presented for endoscopy were administered a questionnaire containing the functional dyspepsia and irritable bowel syndrome modules of the Rome III diagnostic criteria. Results. Of 192 patients who had functional dyspepsia, epigastric pain syndrome, postprandial distress syndrome, and combination of the two subtypes accounted for 79.2%, 62.5%, and 50%, respectively. Multivariate analysis of the risk factors showed that independent predictors of postprandial distress syndrome were alcohol and irritable bowel syndrome while irritable bowel syndrome was independent predictor of epigastric pain syndrome. Alcohol, smoking, and use of nonsteroidal anti-inflammatory drugs were independent predictors of cooccurrence of postprandial distress syndrome and epigastric pain syndrome. Conclusion. Functional dyspepsia accounts for 62.5% of dyspepsia in a population of black African patients. Regarding symptomatology, epigastric pain syndrome, postprandial distress syndrome, and combination of the two subtypes account for 79.2%, 62.5%, and 50%, respectively. Risk factors for functional dyspepsia are irritable bowel syndrome, alcohol, smoking, and use of nonsteroidal anti-inflammatory drugs.

  4. Current irritability robustly related to current and prior anxiety in bipolar disorder.

    Science.gov (United States)

    Yuen, Laura D; Miller, Shefali; Wang, Po W; Hooshmand, Farnaz; Holtzman, Jessica N; Goffin, Kathryn C; Shah, Saloni; Ketter, Terence A

    2016-08-01

    Although current irritability and current/prior anxiety have been associated in unipolar depression, these relationships are less well understood in bipolar disorder (BD). We investigated relationships between current irritability and current/prior anxiety as well as other current emotions and BD illness characteristics. Outpatients referred to the Stanford Bipolar Disorders Clinic during 2000-2011 were assessed with the Systematic Treatment Enhancement Program for BD (STEP-BD) Affective Disorders Evaluation. Prevalence and clinical correlates of current irritability and current/prior anxiety and other illness characteristics were examined. Among 497 BD outpatients (239 Type I, 258 Type II; 58.1% female; mean ± SD age 35.6 ± 13.1 years), 301 (60.6%) had baseline current irritability. Patients with versus without current irritability had significantly higher rates of current anxiety (77.1% versus 42.9%, p anxiety disorder (73.1% versus 52.6%, p anxiety than to current anhedonia, sadness, or euphoria (all p anxiety associations persisted across current predominant mood states. Current irritability was more robustly related to past anxiety than to all other assessed illness characteristics, including 1° family history of mood disorder, history of alcohol/substance use disorder, bipolar subtype, and current syndromal/subsyndromal depression (all p anxiety. Further studies are warranted to assess longitudinal clinical implications of relationships between irritability and anxiety in BD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Association of Irritability and Anxiety With the Neural Mechanisms of Implicit Face Emotion Processing in Youths With Psychopathology.

    Science.gov (United States)

    Stoddard, Joel; Tseng, Wan-Ling; Kim, Pilyoung; Chen, Gang; Yi, Jennifer; Donahue, Laura; Brotman, Melissa A; Towbin, Kenneth E; Pine, Daniel S; Leibenluft, Ellen

    2017-01-01

    Psychiatric comorbidity complicates clinical care and confounds efforts to elucidate the pathophysiology of commonly occurring symptoms in youths. To our knowledge, few studies have simultaneously assessed the effect of 2 continuously distributed traits on brain-behavior relationships in children with psychopathology. To determine shared and unique effects of 2 major dimensions of child psychopathology, irritability and anxiety, on neural responses to facial emotions during functional magnetic resonance imaging. Cross-sectional functional magnetic resonance imaging study in a large, well-characterized clinical sample at a research clinic at the National Institute of Mental Health. The referred sample included youths ages 8 to 17 years, 93 youths with anxiety, disruptive mood dysregulation, and/or attention-deficit/hyperactivity disorders and 22 healthy youths. The child's irritability and anxiety were rated by both parent and child on the Affective Reactivity Index and Screen for Child Anxiety Related Disorders, respectively. Using functional magnetic resonance imaging, neural response was measured across the brain during gender labeling of varying intensities of angry, happy, or fearful face emotions. In mixed-effects analyses, the shared and unique effects of irritability and anxiety were tested on amygdala functional connectivity and activation to face emotions. The mean (SD) age of participants was 13.2 (2.6) years; of the 115 included, 64 were male. Irritability and/or anxiety influenced amygdala connectivity to the prefrontal and temporal cortex. Specifically, irritability and anxiety jointly influenced left amygdala to left medial prefrontal cortex connectivity during face emotion viewing (F4,888 = 9.20; P differences in neural response to face emotions in several areas (F2, 888 ≥ 13.45; all P emotion dysregulation when very anxious and irritable youth process threat-related faces. Activation in the ventral visual circuitry suggests a mechanism

  6. Electro-Optomechanical Transduction & Quantum Hard-Sphere Model for Dissipative Rydberg-EIT Media

    DEFF Research Database (Denmark)

    Zeuthen, Emil

    by two key parameters, the signal transfer efficiency and added noise temperature. In terms of these, we may evaluate its performance in various tasks ranging from classical signal detection to quantum state conversion between, e.g., superconducting circuitry and traveling optical signals. Having...... transduction functionality into the well-established framework of electrical engineering, thereby facilitating its implementation in potential applications such as nuclear magnetic resonance imaging and radio astronomy. We consider such optomechanical sensing of weak electrical signals and discuss how...... in a cold, optically dense cloud with light fields propagating under the condition of electromagnetically induced transparency (EIT). This can lead to strong and non-linear dissipative dynamics at the quantum level that prevent slow-light polaritons from coexisting within a blockade radius of one another...

  7. Four-sample lactose hydrogen breath test for diagnosis of lactose malabsorption in irritable bowel syndrome patients with diarrhea.

    Science.gov (United States)

    Yang, Jian-Feng; Fox, Mark; Chu, Hua; Zheng, Xia; Long, Yan-Qin; Pohl, Daniel; Fried, Michael; Dai, Ning

    2015-06-28

    To validate 4-sample lactose hydrogen breath testing (4SLHBT) compared to standard 13-sample LHBT in the clinical setting. Irritable bowel syndrome patients with diarrhea (IBS-D) and healthy volunteers (HVs) were enrolled and received a 10 g, 20 g, or 40 g dose lactose hydrogen breath test (LHBT) in a randomized, double-blinded, controlled trial. The lactase gene promoter region was sequenced. Breath samples and symptoms were acquired at baseline and every 15 min for 3 h (13 measurements). The detection rates of lactose malabsorption (LM) and lactose intolerance (LI) for a 4SLHBT that acquired four measurements at 0, 90, 120, and 180 min from the same data set were compared with the results of standard LHBT. Sixty IBS-D patients and 60 HVs were studied. The genotype in all participants was C/C-13910. LM and LI detection rates increased with lactose dose from 10 g, 20 g to 40 g in both groups (P lactose doses in both groups. Reducing the number of measurements from 13 to 4 samples did not significantly impact on the accuracy of LHBT in health and IBS-D. 4SLHBT is a valid test for assessment of LM and LI in clinical practice.

  8. Review of Rifaximin: Latest Treatment Frontier for Irritable Bowel Syndrome Mechanism of Action and Clinical Profile

    Directory of Open Access Journals (Sweden)

    Kamesh Gupta

    2017-08-01

    Full Text Available Background: Irritable bowel syndrome is classified as a functional gastrointestinal disorder with the primary symptom of abdominal pain in conjunction with bloating and bowel movement disorder. It affects up to 15% of the world’s population. Among its subtypes, the most common is diarrhoea predominant. However, the current treatment options for diarrhoea-predominant irritable bowel syndrome have had not very promising results; most, such as antispasmodics, only provide partial symptomatic relief. Treatment with antidepressants and alosetron (a 5HT3 antagonist has shown the most promise to date. The latest drug to be approved for the treatment of irritable bowel syndrome-diarrhoea is rifaximin, which was approved in May 2015. It is a minimally absorbed antibiotic that is used to change the gut microbiota. Small intestinal bacterial overgrowth is one of the causes suggested for irritable bowel syndrome, particularly for the diarrhoea-predominant type. There are various methods for detecting bacterial overgrowth, the simplest of which is breath tests. Rifaximin has been shown to be of benefit to these patients. Purpose: The purpose of the study is to discuss the potential mechanism of action of rifaximin, a minimally absorbed antibiotic. In addition, we evaluate the various clinical trials undertaken to study the efficacy and safety profile of rifaximin.

  9. A tiered approach to the use of alternatives to animal testing for the safety assessment of cosmetics: eye irritation.

    Science.gov (United States)

    McNamee, Pauline; Hibatallah, Jalila; Costabel-Farkas, Margit; Goebel, Carsten; Araki, Daisuke; Dufour, Eric; Hewitt, Nicola J; Jones, Penny; Kirst, Annette; Le Varlet, Béatrice; Macfarlane, Martin; Marrec-Fairley, Monique; Rowland, Joanna; Schellauf, Florian; Scheel, Julia

    2009-07-01

    The need for alternative approaches to replace the in vivo rabbit Draize eye test for evaluation of eye irritation of cosmetic ingredients has been recognised by the cosmetics industry for many years. Extensive research has lead to the development of several assays, some of which have undergone formal validation. Even though, to date, no single in vitro assay has been validated as a full replacement for the rabbit Draize eye test, organotypic assays are accepted for specific and limited regulatory purposes. Although not formally validated, several other in vitro models have been used for over a decade by the cosmetics industry as valuable tools in a weight of evidence approach for the safety assessment of ingredients and finished products. In light of the deadlines established in the EU Cosmetics Directive for cessation of animal testing for cosmetic ingredients, a COLIPA scientific meeting was held in Brussels on 30th January, 2008 to review the use of alternative approaches and to set up a decision-tree approach for their integration into tiered testing strategies for hazard and safety assessment of cosmetic ingredients and their use in products. Furthermore, recommendations are given on how remaining data gaps and research needs can be addressed.

  10. Comparison of the effect of glycerol and triamcinolone acetonide on cumulative skin irritation in a randomized trial

    DEFF Research Database (Denmark)

    Andersen, Flemming; Hedegaard, Kathryn; Petersen, Thomas Kongstad

    2007-01-01

    BACKGROUND: So-called anti-irritants are added to cosmetic formulations because of their alleged beneficial effect on irritated skin. Documentation for these claims is often limited. However, glycerol has shown anti-irritant properties in experimentally induced irritation from sodium lauryl sulfate...... volunteers. METHODS: Irritation was induced by 3 daily arm washes for a week with 10% sodium lauryl sulfate on one arm and 30% NON on the other. To maintain irritation, for the next 12 days volunteers washed their arms twice daily with the irritants. Treatments were applied immediately after washing....... The treatments (including vehicle and no treatment) were randomized to sites using a Latin square design. The reactions were evaluated clinically and instrumentally. LIMITATIONS: Study was designed to only detect potent anti-irritants. CONCLUSION: Glycerol reduced the irritant effect of both sodium lauryl...

  11. [Estimation of small intestinal bacterial overgrowth in patients with constipation and diarrhea irritable bowel syndrome].

    Science.gov (United States)

    Łokieć, Katarzyna; Klupińska, Grazyna; Walecka-Kapica, Ewa; Błońska, Aleksandra

    2014-05-01

    Irritable bowel syndrome (IBS) is one of the most common reason for gastroenterology consultations. The diverse in symptomatology of the disease comes from its rich etiopathogenesis. Recently studies talk about infectious etiology of IBS and because of that it is necessary to expand its diagnostics by small intestinal bacterial overgrowth (SIBO) test. The aim of this study was to evaluate the prevalence of small intestinal bacterial overgrowth in patients with constipation (IBS-C) and diarrhea (IBS-D) irritable bowel syndrome with regard to nutrition. The study involved 46 subjects (33 women and 13 men) in average age of 44 years, which were divided into two groups: diarrhea and constipation IBS. All patients underwent hydrogen breath test studying bacterial overgrowth in the small intestine. In addition, each person had fulfilled a feeding questionnaire. Student's t-test, Pearson test. It has been shown that there is no statistical significances between the prevalence of SIBO in form of diarrheal IBS and constipation IBS and gender. Average value of increments of hydrogen in breath during the test was higher in IBS-C in comparison with IBS-D, which was the highest in the intestine bacterial overgrowth in patients with IBS-C. STATISTICAL ANALYSIS showed that there is no relationship between the type and frequency of consumption of milk, meat, fruit and vegetables, sweets and coffee and the prevalence of SIBO in form of diarrhea and constipation IBS. The occurrence of constipation or diarrhea irritable bowel syndrome is not related to gender. SIBO is more common in patients with IBS-C than in IBS-D group. There is no relationship between the type of food consumed and the amount of SIBO in people with IBS. Type of food intake do not affect the status of the intestinal flora of people with IBS.

  12. Irritable bowel syndrome: the burden and unmet needs in Europe.

    LENUS (Irish Health Repository)

    Quigley, E M M

    2012-02-03

    Irritable bowel syndrome affects approximately 10-15% of the European population, although prevalence rates vary depending on the classification used and the country surveyed. This may be due to differences in patterns of medical care and diagnosis of the condition. Up to 70% of individuals with irritable bowel syndrome may not have been formally diagnosed. The disorder affects 1.5-3 times as many women as men and poses a significant economic burden in Europe, estimated at euro 700-euro 1600 per person per year. It also reduces quality of life and is associated with psychological distress, disturbed work and sleep, and sexual dysfunction. It is a chronic disorder, which affects many individuals for more than 10 years. Most patients are managed in primary care, although some are referred to gastroenterologists and other specialists. Patients with irritable bowel syndrome undergo more abdomino-pelvic surgery than the general population. We propose that a positive diagnosis of the condition may avoid the delay in diagnosis many patients experience. We conclude that, in Europe, there are significant unmet needs including lack of familiarity with irritable bowel syndrome, difficulties in diagnosis and lack of effective treatments for the multiple symptoms of the disorder. The development of pan-European guidelines for irritable bowel syndrome will benefit patients with this condition in Europe.

  13. Pengaruh Entertainment, Irritating dan Informativeness Iklan di Website di Kalangan Mahasiswa

    Directory of Open Access Journals (Sweden)

    Edy Supriyadi

    2010-09-01

    Full Text Available There are several advantages and disadvantages and advertising via the Internet. The appeal of advertising may also arise from given information element, the element of comfort but also sometimes lead to disturbing or irritation elements. The limited number of Internet users in Indonesia and the different backgrounds of individual Internet users in Indonesia certainly provide a different assessment of the advertisements contained on the Internet. There are 3 factors which was the starting point to explain how consumers interpret the value of advertising, namely: informativeness, entertainment and irritation. This research aims to discover whether there is a relationship between entertainment, informativeness, and irritation toward advertising values and whether there is a relationship between entertainment and advertising values toward attitude towards web advertising using statistics tools of path analysis and multiple regression. The research shows that there is a significant relationship between independent variables such as informativeness, entertainment and irritation simultaneously toward the advertising value but there are no significant relationship between entertainment and informativeness toward the advertising value individually.  In the other model there is a significant relationship between informativeness, irritation and advertising values with the attitude towards web advertising.

  14. Menthol attenuates respiratory irritation and elevates blood cotinine in cigarette smoke exposed mice.

    Directory of Open Access Journals (Sweden)

    Michael A Ha

    Full Text Available Addition of menthol to cigarettes may be associated with increased initiation of smoking. The potential mechanisms underlying this association are not known. Menthol, likely due to its effects on cold-sensing peripheral sensory neurons, is known to inhibit the sensation of irritation elicited by respiratory irritants. However, it remains unclear whether menthol modulates cigarette smoke irritancy and nicotine absorption during initial exposures to cigarettes, thereby facilitating smoking initiation. Using plethysmography in a C57Bl/6J mouse model, we examined the effects of L-menthol, the menthol isomer added to cigarettes, on the respiratory sensory irritation response to primary smoke irritants (acrolein and cyclohexanone and smoke of Kentucky reference 2R4 cigarettes. We also studied L-menthol's effect on blood levels of the nicotine metabolite, cotinine, immediately after exposure to cigarette smoke. L-menthol suppressed the irritation response to acrolein with an apparent IC₅₀ of 4 ppm. Suppression was observed even at acrolein levels well above those necessary to produce a maximal response. Cigarette smoke, at exposure levels of 10 mg/m³ or higher, caused an immediate and marked sensory irritation response in mice. This response was significantly suppressed by L-menthol even at smoke concentrations as high as 300 mg/m³. Counterirritation by L-menthol was abolished by treatment with a selective inhibitor of Transient Receptor Potential Melastatin 8 (TRPM8, the neuronal cold/menthol receptor. Inclusion of menthol in the cigarette smoke resulted in roughly a 1.5-fold increase in plasma cotinine levels over those observed in mice exposed to smoke without added menthol. These findings document that, L-menthol, through TRPM8, is a strong suppressor of respiratory irritation responses, even during highly noxious exposures to cigarette smoke or smoke irritants, and increases blood cotinine. Therefore, L-menthol, as a cigarette additive, may

  15. Transfer and conversion of images based on EIT in atom vapor.

    Science.gov (United States)

    Cao, Mingtao; Zhang, Liyun; Yu, Ya; Ye, Fengjuan; Wei, Dong; Guo, Wenge; Zhang, Shougang; Gao, Hong; Li, Fuli

    2014-05-01

    Transfer and conversion of images between different wavelengths or polarization has significant applications in optical communication and quantum information processing. We demonstrated the transfer of images based on electromagnetically induced transparency (EIT) in a rubidium vapor cell. In experiments, a 2D image generated by a spatial light modulator is used as a coupling field, and a plane wave served as a signal field. We found that the image carried by coupling field could be transferred to that carried by signal field, and the spatial patterns of transferred image are much better than that of the initial image. It also could be much smaller than that determined by the diffraction limit of the optical system. We also studied the subdiffraction propagation for the transferred image. Our results may have applications in quantum interference lithography and coherent Raman spectroscopy.

  16. Irritancy and Allergic Responses Induced by Exposure to the Indoor Air Chemical 4-Oxopentanal

    Science.gov (United States)

    Anderson, Stacey E.; Franko, Jennifer; Jackson, Laurel G.; Wells, J. R.; Ham, Jason E.; Meade, B. J.

    2012-01-01

    Over the last two decades, there has been an increasing awareness regarding the potential impact of indoor air pollution on human health. People working in an indoor environment often experience symptoms such as eye, nose, and throat irritation. Investigations into these complaints have ascribed the effects, in part, to compounds emitted from building materials, cleaning/consumer products, and indoor chemistry. One suspect indoor air contaminant that has been identified is the dicarbonyl 4-oxopentanal (4-OPA). 4-OPA is generated through the ozonolysis of squalene and several high-volume production compounds that are commonly found indoors. Following preliminary workplace sampling that identified the presence of 4-OPA, these studies examined the inflammatory and allergic responses to 4-OPA following both dermal and pulmonary exposure using a murine model. 4-OPA was tested in a combined local lymph node assay and identified to be an irritant and sensitizer. A Th1-mediated hypersensitivity response was supported by a positive response in the mouse ear swelling test. Pulmonary exposure to 4-OPA caused a significant elevation in nonspecific airway hyperreactivity, increased numbers of lung-associated lymphocytes and neutrophils, and increased interferon-γ production by lung-associated lymph nodes. These results suggest that both dermal and pulmonary exposure to 4-OPA may elicit irritant and allergic responses and may help to explain some of the adverse health effects associated with poor indoor air quality. PMID:22403157

  17. Establishment of a new immortalized human corneal epithelial cell line (iHCE-NY1) for use in evaluating eye irritancy by in vitro test methods.

    Science.gov (United States)

    Yamamoto, Naoki; Kato, Yoshinao; Sato, Atsushi; Hiramatsu, Noriko; Yamashita, Hiromi; Ohkuma, Mahito; Miyachi, Ei-Ichi; Horiguchi, Masayuki; Hirano, Koji; Kojima, Hajime

    2016-08-01

    In vitro test methods that use human corneal epithelial cells to evaluate the eye irritation potency of chemical substances do not use human corneal epithelium because it has been difficult to maintain more than four passages. In this study, we make a new cell line comprising immortalized human corneal epithelial cells (iHCE-NY1). The IC50 of iHCE-NY1 cells is slightly higher than that of Statens Seruminstitut Rabbit Cornea (SIRC) cells, which are currently used in some in vitro test methods. CDKN1A in iHCE-NY1 cells was used as a marker of gene expression to indicate cell cycle activity. This enabled us to evaluate cell recovery characteristics at concentrations lower than the IC50 of cytotoxic tests.

  18. Estimation of the chemical-induced eye injury using a weight-of-evidence (WoE) battery of 21 artificial neural network (ANN) c-QSAR models (QSAR-21): part I: irritation potential.

    Science.gov (United States)

    Verma, Rajeshwar P; Matthews, Edwin J

    2015-03-01

    Evaluation of potential chemical-induced eye injury through irritation and corrosion is required to ensure occupational and consumer safety for industrial, household and cosmetic ingredient chemicals. The historical method for evaluating eye irritant and corrosion potential of chemicals is the rabbit Draize test. However, the Draize test is controversial and its use is diminishing - the EU 7th Amendment to the Cosmetic Directive (76/768/EEC) and recast Regulation now bans marketing of new cosmetics having animal testing of their ingredients and requires non-animal alternative tests for safety assessments. Thus, in silico and/or in vitro tests are advocated. QSAR models for eye irritation have been reported for several small (congeneric) data sets; however, large global models have not been described. This report describes FDA/CFSAN's development of 21 ANN c-QSAR models (QSAR-21) to predict eye irritation using the ADMET Predictor program and a diverse training data set of 2928 chemicals. The 21 models had external (20% test set) and internal validation and average training/verification/test set statistics were: 88/88/85(%) sensitivity and 82/82/82(%) specificity, respectively. The new method utilized multiple artificial neural network (ANN) molecular descriptor selection functionalities to maximize the applicability domain of the battery. The eye irritation models will be used to provide information to fill the critical data gaps for the safety assessment of cosmetic ingredient chemicals. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Irritancy potential of 17 detergents used commonly by the Indian household

    Directory of Open Access Journals (Sweden)

    Austoria A

    2010-01-01

    Full Text Available Background: Detergents are used by almost every household in the developed and developing world. Soap and most detergents are anionic surfactants and attack the horny layer of the skin and increase its permeability with little or no inflammatory change and may result in hand eczema, which is very distressing and incapacitating. Aim: To evaluate the irritant potential of common household detergents (laundry and dish wash used by the Indian population using a 24-hour patch test and to convincingly educate the patients on the detergents less likely to cause irritation in the particular individual. Methods: Seventeen commonly used detergents found in Indian market were included in the study, of which, 12 were laundry detergents (powders - seven, bar soap - five and five were dish wash detergents (powder - one, liquid - one, bar soap - three. The irritant potential of the 17 detergents were evaluated in 30 volunteers. Thirty microliters of each of the detergent bar solutions, distilled water (negative control, and 20% SDS (positive control were applied to Finn chambers with a micropipette and occluded for 24 hours. Erythema, scaling, and edema were graded in comparison to the reaction at the negative control site (distilled water for each volunteer separately. The scoring of erythema / dryness and wrinkling on a 0 - 4 point scale and edema on another 0 - 4 point scale was based on the Draize scale. The pH of each of the detergent solutions was determined using litmus papers (Indikrom papers from Qualigens fine chemicals. Results: The difference between detergents (F value was significant for erythema / dryness and wrinkling (F = 3.374; p = 0.000, but not significant for edema (F = 1.297; p = 0.194. [Table 2] lists the means for erythema / dryness and wrinkling, and edema. The F value of the totals of the means for erythema / dryness and wrinkling and edema was significant (F = 2.495; p = 0.001. The pH of all the detergents was found to be alkaline

  20. Postanaesthetic tear production and ocular irritation in cats.

    Science.gov (United States)

    Peche, N; Köstlin, R; Reese, S; Pieper, K

    2015-01-01

    General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.

  1. Indirect measurement of lung density and air volume from electrical impedance tomography (EIT) data.

    Science.gov (United States)

    Nebuya, Satoru; Mills, Gary H; Milnes, Peter; Brown, Brian H

    2011-12-01

    This paper describes a method for estimating lung density, air volume and changes in fluid content from a non-invasive measurement of the electrical resistivity of the lungs. Resistivity in Ω m was found by fitting measured electrical impedance tomography (EIT) data to a finite difference model of the thorax. Lung density was determined by comparing the resistivity of the lungs, measured at a relatively high frequency, with values predicted from a published model of lung structure. Lung air volume can then be calculated if total lung weight is also known. Temporal changes in lung fluid content will produce proportional changes in lung density. The method was implemented on EIT data, collected using eight electrodes placed in a single plane around the thorax, from 46 adult male subjects and 36 adult female subjects. Mean lung densities (±SD) of 246 ± 67 and 239 ± 64 kg m(-3), respectively, were obtained. In seven adult male subjects estimates of 1.68 ± 0.30, 3.42 ± 0.49 and 4.40 ± 0.53 l in residual volume, functional residual capacity and vital capacity, respectively, were obtained. Sources of error are discussed. It is concluded that absolute differences in lung density of about 30% and changes over time of less than 30% should be detected using the current technology in normal subjects. These changes would result from approximately 300 ml increase in lung fluid. The method proposed could be used for non-invasive monitoring of total lung air and fluid content in normal subjects but needs to be assessed in patients with lung disease.

  2. The use of a measure of acute irritation to predict the outcome of repeated usage of hand soap products.

    Science.gov (United States)

    Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S

    2011-06-01

    Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a

  3. An approach for evaluating the respiratory irritation of mixtures: application to metalworking fluids.

    Science.gov (United States)

    Schaper, M M; Detwiler-Okabayashi, K A

    1995-01-01

    Recently, the sensory and pulmonary irritating properties of ten metalworking fluids (MWF) were assessed using a mouse bioassay. Relative potency of the MWFs was estimated, but it was not possible to identify the component(s) responsible for the the respiratory irritation induced by each MWF. One of the ten fluids, MWF "ET", produced sensory and pulmonary irritation in mice, and it was of moderate potency in comparison to the other nine MWFs. MWF "E" had three major components: tall oil fatty acids (TOFA), sodium sulfonate (SA), and paraffinic oil (PO). In the present study, the sensory and pulmonary irritating properties of these individual components of MWF "E" were evaluated. Mixtures of the three components were also prepared and similarly evaluated. This analysis revealed that the sensory irritation from MWF "E" was largely due to TOFA, whereas SA produced the pulmonary irritation observed with MWF "E". Both TOFA and SA were more potent irritants than was MWF "E", and the potency of TOFA and/or SA was diminished through combination with PO. There was no evidence of synergism of the components when combined to form MWF "E". This approach for identifying the biologically "active" component(s) in a mixture should be useful for other MWFs. Furthermore, the approach should be easily adapted for other applications involving concerns with mixtures.

  4. Stratum corneum cytokines and skin irritation response to sodium lauryl sulfate

    NARCIS (Netherlands)

    de Jongh, Cindy M.; Verberk, Maarten M.; Withagen, Carien E. T.; Jacobs, John J. L.; Rustemeyer, Thomas; Kezic, Sanja

    2006-01-01

    Little is known about cytokines involved in chronic irritant contact dermatitis. Individual cytokine profiles might explain at least part of the differences in the individual response to irritation. Our objective was to investigate the relation between baseline stratum corneum (SC) cytokine levels

  5. Irritability and Parenting Styles in Adolescents With Attention-Deficit/Hyperactivity Disorder: A Controlled Study.

    Science.gov (United States)

    Uçar, Halit Necmi; Vural, Ayşe Pınar

    2018-04-17

    Attention-deficit/hyperactivity disorder (ADHD) affects functioning of the family, decreasing interactions and loyalty and increasing conflict between adolescents with ADHD and their families. Irritable mood and difficulties with emotional dysregulation are common in children with ADHD. The objective of the current study was to assess levels of irritability in adolescents with ADHD using self- and parent-report scales, and investigate the relationship between irritability levels and parental attitudes. A total of 47 adolescents with ADHD and 39 adolescents with typical development participated in the current study. Findings demonstrated that higher levels of parent-reported irritability were associated with decreased egalitarian attitudes in the ADHD group. Although other parental attitudes were not associated with self- and parent-reported irritability, evaluation of the relationship between parental attitudes and irritability in adolescents with ADHD, which can guide diagnosis and treatment of ADHD, is of critical importance. [Journal of Psychosocial Nursing and Mental Health Services, xx(x), xx-xx.]. Copyright 2018, SLACK Incorporated.

  6. Irritability, Externalizing, and Internalizing Psychopathology in Adolescence: Cross-Sectional and Longitudinal Associations and Moderation by Sex.

    Science.gov (United States)

    Humphreys, Kathryn L; Schouboe, Sophie N F; Kircanski, Katharina; Leibenluft, Ellen; Stringaris, Argyris; Gotlib, Ian H

    2018-04-18

    Irritability is a common feature of many psychiatric disorders, including both externalizing and internalizing disorders. There is little research, however, examining associations between irritability and these symptom domains, particularly during the important developmental period of adolescence, characterized by sex differences in the prevalence of disorders. We examined the cross-sectional associations between irritability, measured with the Affective Reactivity Index, and symptoms of externalizing and internalizing domains of psychopathology, measured with the Youth Self Report, in a volunteer community sample (N = 183) of 9- to 13-year-old (M = 11.39, SD = 1.07) boys and girls (37% White/Caucasian, 8% Asian, 11% Hispanic, 8% African American, 2% Native American, 2% Pacific Islander, 28% Other, and 3% not reported). A subset of the sample (n = 112) provided data at a 2-year follow-up, used to extend these associations. There were no sex differences in levels of irritability; however, the associations between irritability and symptom domains were moderated by sex. Specifically, in girls, irritability was associated equally with externalizing and internalizing symptoms. In contrast, in boys, irritability was associated more strongly with externalizing symptoms than with internalizing symptoms. Thus, across both sexes, irritability was moderately associated with externalizing symptoms, but the association between irritability and internalizing symptoms was stronger in girls than in boys. At follow-up, sex moderated the association between baseline irritability and later externalizing and internalizing symptoms. These findings indicate that irritability is associated with both externalizing and internalizing symptoms in early adolescence and that irritability is associated with internalizing symptoms more strongly in girls than in boys.

  7. Irritability Trajectories, Cortical Thickness, and Clinical Outcomes in a Sample Enriched for Preschool Depression.

    Science.gov (United States)

    Pagliaccio, David; Pine, Daniel S; Barch, Deanna M; Luby, Joan L; Leibenluft, Ellen

    2018-05-01

    Cross-sectional, longitudinal, and genetic associations exist between irritability and depression. Prior studies have examined developmental trajectories of irritability, clinical outcomes, and associations with child and familial depression. However, studies have not integrated neurobiological measures. The present study examined developmental trajectories of irritability, clinical outcomes, and cortical structure among preschoolers oversampled for depressive symptoms. Beginning at 3 to 5 years old, a sample of 271 children enriched for early depressive symptoms were assessed longitudinally by clinical interview. Latent class mixture models identified trajectories of irritability severity. Risk factors, clinical outcomes, and cortical thickness were compared across trajectory classes. Cortical thickness measures were extracted from 3 waves of magnetic resonance imaging at 7 to 12 years of age. Three trajectory classes were identified among these youth: 53.50% of children exhibited elevated irritability during preschool that decreased longitudinally, 30.26% exhibited consistently low irritability, and 16.24% exhibited consistently elevated irritability. Compared with other classes, the elevated irritability class exhibited higher rates of maternal depression, early life adversity, later psychiatric diagnoses, and functional impairment. Further, elevated baseline irritability predicted later depression beyond adversity and personal and maternal depression history. The elevated irritability class exhibited a thicker cortex in the left superior frontal and temporal gyri and the right inferior parietal lobule. Irritability manifested with specific developmental trajectories in this sample enriched for early depression. Persistently elevated irritability predicted poor psychiatric outcomes, higher risk for later depression, and decreased overall function later in development. Greater frontal, temporal, and parietal cortical thickness also was found, providing neural

  8. Laboratory scale tests of electrical impedence tomography

    International Nuclear Information System (INIS)

    Binley, A; Daily, W; LaBredcque, D; Ramirez, A.

    1998-01-01

    Electrical impedance tomographs (magnitude and phase) of known, laboratory-scale targets are reported. Three methods are used to invert electrical impedance data and their tomographs compared. The first method uses an electrical resistance tomography (ERT) algonthm (designed for DC resistivity inversion) to perform impedance magnitude inversion and a linearized perturbation approach (PA) to invert the imaginary part. The second approximate method compares ERT magnitude inversions at two frequencies and uses the frequency effect (FE) to compute phase tomographs. The third approach, electrrcal impedance tomography (EIT), employs fully complex algebra to account for the real and imaginary components of electrical impedance data. The EIT approach provided useful magnitude and phase images for the frequency range of 0.0625 to 64 Hz; images for higher frequencies were not reliable. Comparisons of the ERT and EIT magnitude images show that both methods provided equivalent results for the water blank, copper rod and PVC rod targets. The EIT magnitude images showed better spatial resolutron for a sand-lead mixture target. Phase images located anomalies of both high and low contrast IP and provided better spatial resolution than the magnitude images. When IP was absent from the data, the EIT algorithm reconstructed phase values consistent with the data noise levels

  9. Moreton wave, "EIT wave", and type II radio burst as manifestations of a single wave front

    Science.gov (United States)

    Kuzmenko, I. V.; Grechnev, V. V.; Uralov, A. M.

    2011-12-01

    We show that a Moreton wave, an "EIT wave," and a type II radio burst observed during a solar flare of July 13, 2004, might have been a manifestation of a single front of a decelerating shock wave, which appeared in an active region (AR) during a filament eruption. We propose describing a quasi-spheroidal wave propagating upward and along the solar surface by using relations known from a theory of a point-like explosion in a gas whose density changes along the radius according to a power law. By applying this law to fit the drop in density of the coronal plasma enveloping the solar active region, we first managed to bring the measured positions and velocities of surface Moreton wave and "EIT wave" into correspondence with the observed frequency drift rate of the meter type II radio burst. The exponent of the vertical coronal density falloff is selected by fitting the power law to the Newkirk and Saito empirical distributions in the height range of interest. Formal use of such a dependence in the horizontal direction with a different exponent appears to be reasonable up to distances of less than 200 Mm around the eruption center. It is possible to assume that the near-surface shock wave weakens when leaving this radius and finally the active region, entering the region of the quiet Sun where the coronal plasma density and the fast-mode speed are almost constant along the horizontal.

  10. Unveiling the development of intracranial injury using dynamic brain EIT: an evaluation of current reconstruction algorithms.

    Science.gov (United States)

    Li, Haoting; Chen, Rongqing; Xu, Canhua; Liu, Benyuan; Tang, Mengxing; Yang, Lin; Dong, Xiuzhen; Fu, Feng

    2017-08-21

    Dynamic brain electrical impedance tomography (EIT) is a promising technique for continuously monitoring the development of cerebral injury. While there are many reconstruction algorithms available for brain EIT, there is still a lack of study to compare their performance in the context of dynamic brain monitoring. To address this problem, we develop a framework for evaluating different current algorithms with their ability to correctly identify small intracranial conductivity changes. Firstly, a simulation 3D head phantom with realistic layered structure and impedance distribution is developed. Next several reconstructing algorithms, such as back projection (BP), damped least-square (DLS), Bayesian, split Bregman (SB) and GREIT are introduced. We investigate their temporal response, noise performance, location and shape error with respect to different noise levels on the simulation phantom. The results show that the SB algorithm demonstrates superior performance in reducing image error. To further improve the location accuracy, we optimize SB by incorporating the brain structure-based conductivity distribution priors, in which differences of the conductivities between different brain tissues and the inhomogeneous conductivity distribution of the skull are considered. We compare this novel algorithm (called SB-IBCD) with SB and DLS using anatomically correct head shaped phantoms with spatial varying skull conductivity. Main results and Significance: The results showed that SB-IBCD is the most effective in unveiling small intracranial conductivity changes, where it can reduce the image error by an average of 30.0% compared to DLS.

  11. An analysis of human response to the irritancy of acetone vapors

    NARCIS (Netherlands)

    Arts, J.H.E.; Mojet, J.; Gemert, L.J. van; Emmen, H.H.; Lammers, J.H.C.M.; Marquart, J.; Woutersen, R.A.; Feron, V.J.

    2002-01-01

    Studies on the irritative effects of acetone vapor in humans and experimental animals have revealed large differences in the lowest acetone concentration found to be irritative to the respiratory tract and eyes. This has brought on much confusion in the process of setting occupational exposure

  12. IRRITABLE BOWEL SYNDROME IN CHILDREN: DIAGNOSTICS AND MODERN APPROACHES TO THERAPY

    Directory of Open Access Journals (Sweden)

    S.Yu. Tereshchenko

    2006-01-01

    Full Text Available In the article modern data on prevalence, diagnostic criteria and approaches to the treatment of irritable bowel in children are presented. The issues of the terminology and classification of recurrent abdominal pains in children are clarified, the basic pathophysiological mechanisms of the disease are indicated. Particular emphasis has been placed on the efficient therapy of the different clinical variants of irritable bowel syndrome. The role of modern spasmolytic drugs in the treatment of abdominal pain syndrome and the rational usage of laxatives in constipation in children is shown.Key words: children, irritable bowel syndrome, diagnostics, treatment.

  13. Newborn Irritability Moderates the Association between Infant Attachment Security and Toddler Exploration and Sociability

    Science.gov (United States)

    Stupica, Brandi; Sherman, Laura J.; Cassidy, Jude

    2011-01-01

    This longitudinal investigation of 84 infants examined whether the effect of 12-month attachment on 18- and 24-month exploration and sociability with unfamiliar adults varied as a function of newborn irritability. As expected, results revealed an interaction between attachment (secure vs. insecure) and irritability (highly irritable vs. moderately…

  14. Evaluation of 4-methylcyclohexanemethanol (MCHM) in a combined irritancy and Local Lymph Node Assay (LLNA) in mice.

    Science.gov (United States)

    Johnson, Victor J; Auerbach, Scott S; Luster, Michael I; Waidyanatha, Suramya; Masten, Scott A; Wolfe, Mary S; Burleson, Florence G; Burleson, Gary R; Germolec, Dori R

    2017-07-01

    4-Methylcyclohexanemethanol (MCHM) is a flotation reagent used in fine coal beneficiation. On January 9, 2014, crude MCHM, a mixture containing predominantly MCHM, was inadvertently released into the Elk River, a municipal water source that serves about 300,000 people in the Charleston, WV area, resulting in temporary contamination of 15 percent of the state's tap water and causing significant dermal exposure. The current studies were undertaken to determine whether crude MCHM or MCHM has the potential to produce dermal irritancy and/or sensitization. BALB/c female mice were treated daily for 3 consecutive days by direct epicutaneous application of 25 μL of various concentrations of crude MCHM or MCHM to the dorsum of each ear. A mouse ear-swelling test was used to determine irritancy potential and was undertaken in combination with the standardized Local Lymph Node Assay (LLNA) to determine skin sensitizing potential. MCHM was found to produce skin irritation at concentrations above 20% and did not produce sensitization. Crude MCHM also produced irritation, although weaker, and in addition was found to be a weak to moderate skin sensitizer. The results are discussed in terms of potential human health hazard. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Non-Irritant Baby Shampoos May Cause Cataract Development

    Directory of Open Access Journals (Sweden)

    Omer Faruk Tekbas

    2008-02-01

    Full Text Available BACKGROUND: The effect of different shampoo formulations as a risk factor for cataract formation was investigated in Sprague Dawley rats in the present study. METHODS: Study was performed by using 20 rats. Two different shampoos used by adult subjects and two different baby shampoos were used in the study. Different shampoos were used in different groups for 14 days, and they were followed for changes. RESULTS: Different degree of opacities were observed in 4 (40%, 4 (40%, 5 (50%, and 6 (60% eyes in Groups A, B, C, and D, respectively. There was no statistically significant difference for formation of cataract between the groups (p>0.05. The number of irritated eyes was significantly lower (p<0.05 in groups C (10% and D (20% compared to groups A (90% and B (80%. CONCLUSION: The use of non-irritant baby shampoos does not seem to eliminate the risk of cataract formation and these should even be used more carefully as the non-irritant shampoo will have more contact with the eye. [TAF Prev Med Bull. 2008; 7(1: 1-6

  16. Transcutaneous sacral neurostimulation for irritative voiding dysfunction.

    Science.gov (United States)

    Walsh, I K; Johnston, R S; Keane, P F

    1999-01-01

    Patients with irritative voiding dysfunction are often unresponsive to standard clinical treatment. We evaluated the response of such individuals to transcutaneous electrical stimulation of the third sacral nerve. 32 patients with refractory irritative voiding dysfunction (31 female and 1 male; mean age 47 years) were recruited to the study. Ambulatory transcutaneous electrical neurostimulation was applied bilaterally to the third sacral dermatomes for 1 week. Symptoms of frequency, nocturia, urgency, and bladder pain were scored by each patient throughout and up to 6 months following treatment. The mean daytime frequency was reduced from 11.3 to 7.96 (p = 0.01). Nocturia episodes were reduced from a mean of 2.6 to 1.8 (p = 0.01). Urgency and bladder pain mean symptom scores were reduced from 5.97 to 4.89 and from 1.48 to 0.64, respectively. After stopping therapy, symptoms returned to pretreatment levels within 2 weeks in 40% of the patients and within 6 months in 100%. Three patients who continued with neurostimulation remained satisfied with this treatment modality at 6 months. Transcutaneous third sacral nerve stimulation may be an effective and noninvasive ambulatory technique for the treatment of patients with refractory irritative voiding dysfunction. Following an initial response, patients may successfully apply this treatment themselves to ensure long-term relief.

  17. Neuronal activation by mucosal biopsy supernatants from irritable bowel syndrome patients is linked to visceral sensitivity

    NARCIS (Netherlands)

    Buhner, Sabine; Braak, Breg; Li, Qin; Kugler, Eva Maria; Klooker, Tamira; Wouters, Mira; Donovan, Jemma; Vignali, Sheila; Mazzuoli-Weber, Gemma; Grundy, David; Boeckxstaens, Guy; Schemann, Michael

    2014-01-01

    Based on the discomfort/pain threshold during rectal distension, irritable bowel syndrome (IBS) patients may be subtyped as normo- or hypersensitive. We previously showed that mucosal biopsy supernatants from IBS patients activated enteric and visceral afferent neurons. We tested the hypothesis that

  18. Pediatric Mania: The Controversy between Euphoria and Irritability

    Science.gov (United States)

    Serra, Giulia; Uchida, Mai; Battaglia, Claudia; Casini, Maria Pia; De Chiara, Lavinia; Biederman, Joseph; Vicari, Stefano; Wozniak, Janet

    2017-01-01

    Abstract: Pediatric Bipolar Disorder (BD) is a highly morbid pediatric psychiatric disease, consistently associated with family psychiatric history of mood disorders and associated with high levels of morbidity and disability and with a great risk of suicide. While there is a general consensus on the symptomatology of depression in childhood, the phenomenology of pediatric mania is still highly debated and the course and long-term outcome of pediatric BD still need to be clarified. We reviewed the available studies on the phenomenology of pediatric mania with the aim of summarizing the prevalence, demographics, clinical correlates and course of these two types of pediatric mania. Eighteen studies reported the number of subjects presenting with either irritable or elated mood during mania. Irritability has been reported to be the most frequent clinical feature of pediatric mania reaching a sensitivity of 95–100% in several samples. Only half the studies reviewed reported on number of episodes or cycling patterns and the described course was mostly chronic and ultra-rapid whereas the classical episodic presentation was less common. Few long-term outcome studies have reported a diagnostic stability of mania from childhood to young adult age. Future research should focus on the heterogeneity of irritability aiming at differentiating distinct subtypes of pediatric psychiatric disorders with distinct phenomenology, course, outcome and biomarkers. Longitudinal studies of samples attending to mood presentation, irritable versus elated, and course, chronic versus episodic, may help clarify whether these are meaningful distinctions in the course, treatment and outcome of pediatric onset bipolar disorder. PMID:28503110

  19. Pediatric Mania: The Controversy between Euphoria and Irritability.

    Science.gov (United States)

    Serra, Giulia; Uchida, Mai; Battaglia, Claudia; Casini, Maria Pia; De Chiara, Lavinia; Biederman, Joseph; Vicari, Stefano; Wozniak, Janet

    2017-04-01

    Pediatric Bipolar Disorder (BD) is a highly morbid pediatric psychiatric disease, consistently associated with family psychiatric history of mood disorders and associated with high levels of morbidity and disability and with a great risk of suicide. While there is a general consensus on the symptomatology of depression in childhood, the phenomenology of pediatric mania is still highly debated and the course and long-term outcome of pediatric BD still need to be clarified. We reviewed the available studies on the phenomenology of pediatric mania with the aim of summarizing the prevalence, demographics, clinical correlates and course of these two types of pediatric mania. Eighteen studies reported the number of subjects presenting with either irritable or elated mood during mania. Irritability has been reported to be the most frequent clinical feature of pediatric mania reaching a sensitivity of 95-100% in several samples. Only half the studies reviewed reported on number of episodes or cycling patterns and the described course was mostly chronic and ultra-rapid whereas the classical episodic presentation was less common. Few long-term outcome studies have reported a diagnostic stability of mania from childhood to young adult age. Future research should focus on the heterogeneity of irritability aiming at differentiating distinct subtypes of pediatric psychiatric disorders with distinct phenomenology, course, outcome and biomarkers. Longitudinal studies of samples attending to mood presentation, irritable versus elated, and course, chronic versus episodic, may help clarify whether these are meaningful distinctions in the course, treatment and outcome of pediatric onset bipolar disorder.

  20. Anorectal pain and irritation: anal fissure, levator syndrome, proctalgia fugax, and pruritus ani.

    Science.gov (United States)

    Vincent, C

    1999-03-01

    Anal fissures, proctalgia fugax, levator ani syndrome, and pruritus ani are common causes of anorectal pain and irritation. The clinician who obtains a thorough history and performs a complete examination can accurately diagnose these disorders. Ancillary tests seldom are helpful and rarely are necessary. Most patients suffering from these conditions readily respond to conservative therapy provided in the primary care practitioner's office.

  1. Screening of coeliac disease in undetected adults and patients diagnosed with irritable bowel syndrome in Riyadh, Saudi Arabia.

    Science.gov (United States)

    Al-Ajlan, Abdulrahman S

    2016-07-01

    The present study is to determine the prevalence and implication of coeliac disease (CD) among adult Saudis and compared to those with diagnosed irritable bowel syndrome. This prospective study was conducted among 980 adults. Out of that, 482 subjects (staff and students of Riyadh Health Science College) were designated as control cohorts for undetected coeliac disease. Furthermore, another contingent of 498 subjects diagnosed with irritable bowel syndrome (IBS) at Prince Salman Hospital and Al-Iman General Hospital also constituted a segment of the overall initial 1020 subjects. Both cases and control were tested for serological markers of coeliac disease (tissues transglutaminase (tTGAs) and endomysial autoantibody (EMAs) and were confirmed by histopathology test. All the positive for cases of coeliac disease were screened for iron deficiency anaemia, Vitamin D deficiency, and osteoporosis and weight assessment. The percentage of coeliac disease in control subjects and patients diagnosed with irritable bowel syndrome (IBS) were found to be 1.9% and 9.6% respectively, about 38% of the total coeliac disease patients are among females of middle age (20-39-years) and 16% of the males in the same age range. Whereas, 20% and 25% of all coeliac disease cases with ages of 40-59 were remarked as females and males respectively. The identical nature and overlap of symptoms of the two conditions could possibly result in misdiagnosis of coeliac diseases or over-diagnosis of irritable bowel syndrome. The findings of the study might also give considerable implications of the disease in the nutritional level which is noticeable.

  2. Screening of coeliac disease in undetected adults and patients diagnosed with irritable bowel syndrome in Riyadh, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Abdulrahman S. Al-Ajlan

    2016-07-01

    Full Text Available The present study is to determine the prevalence and implication of coeliac disease (CD among adult Saudis and compared to those with diagnosed irritable bowel syndrome. This prospective study was conducted among 980 adults. Out of that, 482 subjects (staff and students of Riyadh Health Science College were designated as control cohorts for undetected coeliac disease. Furthermore, another contingent of 498 subjects diagnosed with irritable bowel syndrome (IBS at Prince Salman Hospital and Al-Iman General Hospital also constituted a segment of the overall initial 1020 subjects. Both cases and control were tested for serological markers of coeliac disease (tissues transglutaminase (tTGAs and endomysial autoantibody (EMAs and were confirmed by histopathology test. All the positive for cases of coeliac disease were screened for iron deficiency anaemia, Vitamin D deficiency, and osteoporosis and weight assessment. The percentage of coeliac disease in control subjects and patients diagnosed with irritable bowel syndrome (IBS were found to be 1.9% and 9.6% respectively, about 38% of the total coeliac disease patients are among females of middle age (20–39-years and 16% of the males in the same age range. Whereas, 20% and 25% of all coeliac disease cases with ages of 40–59 were remarked as females and males respectively. The identical nature and overlap of symptoms of the two conditions could possibly result in misdiagnosis of coeliac diseases or over-diagnosis of irritable bowel syndrome. The findings of the study might also give considerable implications of the disease in the nutritional level which is noticeable.

  3. Integrating Sustainable Development in Higher Education through Experience-Based Learning: Insights from Experts in Team (EiT) for Developing a Combined Theoretical Framework

    Science.gov (United States)

    Otte, Pia Piroschka

    2016-01-01

    Universities are understood to play an essential role in the promotion of sustainable development. However, the recognition of sustainable development in higher education poses multiple challenges to the traditional higher education system. This article introduces a course concept called "Experts in Teams" (EiT) as a new platform of…

  4. Impact of irritability: a 2-year observational study of outpatients with bipolar I or schizoaffective disorder.

    Science.gov (United States)

    Berk, Lesley; Hallam, Karen T; Venugopal, Kamalesh; Lewis, Andrew James; Austin, David W; Kulkarni, Jayashri; Dodd, Seetal; de Castella, Anthony; Fitzgerald, Paul B; Berk, Michael

    2017-05-01

    Many people experience irritability when manic, hypomanic, or depressed, yet its impact on illness severity and quality of life in bipolar and schizoaffective disorders is poorly understood. This study aimed to examine the relationship between irritability and symptom burden, functioning, quality of life, social support, suicidality, and overall illness severity in a naturalistic cohort of people with bipolar I or schizoaffective disorder. We used data from 239 adult outpatients with bipolar I or schizoaffective disorder in the Bipolar Comprehensive Outcomes Study (BCOS) - a non-interventional observational study with a 2-year follow-up period. Baseline demographic and clinical characteristics of participants with and without irritability were compared. A mixed-model repeated measures analysis was conducted to examine the longitudinal effect of irritability on clinical and quality-of-life variables over follow-up using significant baseline variables. At baseline, 54% of participants were irritable. Baseline irritability was associated with illness severity, mania, depression, psychotic symptoms, suicidality, poor functioning, and quality of life, but not diagnosis (schizoaffective/bipolar disorder). Participants with irritability were less likely to have a partner and perceived less adequate social support. On average, over follow-up, those with irritability reported more symptoms, functional impairment, and suicidality. Furthermore, the effects of irritability could not be fully explained by illness severity. Irritability was associated with more negative symptomatic, functional, and quality-of-life outcomes and suicidality. The identification, monitoring, and targeted treatment of irritability may be worth considering, to enhance health and wellbeing outcomes for adults with bipolar and schizoaffective disorders. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. EIT and SXT Observations of a Quiet Region Filament Ejection: First Eruption, Then Reconnection

    Science.gov (United States)

    Sterling, Alphonse C.; Moore, Ronald L.; Thompson, Barbara J.; Six, N. Frank (Technical Monitor)

    2001-01-01

    We observe a slow-onset quiet-region filament eruption with the EUV Imaging Telescope (EIT) on SOHO, and the Soft X-ray Telescope (SXT) on Yohkoh. This event occurred on 1999 April 18, and was likely the origin of a coronal mass ejection (CME) detected by SOHO at 08:30 UT on that day. In EIT, one-half of the filament shows two stages of evolution: Stage I is a slow, roughly constant upward movement at approx. 1 km per second lasting approximately 6.5 hours, and Stage 2 is a rapid upward eruption at approximately 16 kilometers per second occurring just before the filament disappears into interplanetary space. The other half of the filament shows little motion along the line-of-sight during the time of Stage 1, but erupts along with the rest of the filament during Stage 2. There is no obvious emission from the filament in SXT until Stage 2; at that time an arcade of EUV and soft X-ray loops forms first at the central location of the filament, and then expands outward along the length of the filament channel. A plot of EUV intensity versus time of the central portion of the filament (where the postflare loops initially form) shows a flat profile during Stage 1, and a rapid upturn after the start of Stage 2. This lightcurve is delayed from what would be expected if "tether-cutting" reconnection in the core of the erupting region were responsible for the initiation of the eruption. Rather, these observations suggest that a loss of stability of the magnetic field holding the filament initiates the eruption, with reconnection in the core region occurring only as a byproduct.

  6. EIT And SXT Observations of a Quiet-Region Filament Ejection: First Eruption, Then Reconnection

    Science.gov (United States)

    Sterling, Alphonse C.; Moore, Ronald L.; Thompson, Barbara J.

    2001-01-01

    We observe a slow-onset quiet-region filament eruption with the Extreme Ultraviolet Imaging Telescope (EIT) on the Solar Heliospheric Observatory (SOHO) and the Soft X-ray Telescope (SXT) on Yohkoh. This event occurred on 1999 April 18 and was likely the origin of a coronal mass ejection detected by SOHO at 08:30 UT on that day. In the EIT observation, one-half of the filament shows two stages of evolution: stage 1 is a slow, roughly constant upward movement at approximately 1 km/s lasting approximately 0.5 hr, and stage 2 is a rapid upward eruption at approximately 16 km/s occurring just before the filament disappears into interplanetary space. The other half of the filament shows little motion along the line of sight during the time of stage 1 but erupts along with the rest of the filament during stage 2. There is no obvious emission from the filament in the SXT observation until stage 2; at that time, an arcade of EUV and soft X-ray loops forms first at the central location of the filament and then expands outward along the length of the filament channel. A plot of EUV intensity versus time of the central portion of the filament (where the postflare loops initially form) shows a flat profile during stage 1 and a rapid upturn after the start of stage 2. This light curve is delayed from what would be expected if 'tether-cutting' reconnection in the core of the erupting region were responsible for the initiation of the eruption. Rather, these observations suggest that a loss of stability of the magnetic field holding the filament initiates the eruption, with reconnection in the core region occurring only as a by-product.

  7. MUTZ-3 derived Langerhans cells in human skin equivalents show differential migration and phenotypic plasticity after allergen or irritant exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kosten, Ilona J.; Spiekstra, Sander W. [Department of Dermatology, VU University Medical Center, Amsterdam (Netherlands); Gruijl, Tanja D. de [Department of Dermatology Medical Oncology, VU University Medical Center, Amsterdam (Netherlands); Gibbs, Susan, E-mail: s.gibbs@acta.nl [Department of Dermatology, VU University Medical Center, Amsterdam (Netherlands); Department of Oral Cell Biology, Academic Center for Dentistry (ACTA), Amsterdam (Netherlands)

    2015-08-15

    After allergen or irritant exposure, Langerhans cells (LC) undergo phenotypic changes and exit the epidermis. In this study we describe the unique ability of MUTZ-3 derived Langerhans cells (MUTZ-LC) to display similar phenotypic plasticity as their primary counterparts when incorporated into a physiologically relevant full-thickness skin equivalent model (SE-LC). We describe differences and similarities in the mechanisms regulating LC migration and plasticity upon allergen or irritant exposure. The skin equivalent consisted of a reconstructed epidermis containing primary differentiated keratinocytes and CD1a{sup +} MUTZ-LC on a primary fibroblast-populated dermis. Skin equivalents were exposed to a panel of allergens and irritants. Topical exposure to sub-toxic concentrations of allergens (nickel sulfate, resorcinol, cinnamaldehyde) and irritants (Triton X-100, SDS, Tween 80) resulted in LC migration out of the epidermis and into the dermis. Neutralizing antibody to CXCL12 blocked allergen-induced migration, whereas anti-CCL5 blocked irritant-induced migration. In contrast to allergen exposure, irritant exposure resulted in cells within the dermis becoming CD1a{sup −}/CD14{sup +}/CD68{sup +} which is characteristic of a phenotypic switch of MUTZ-LC to a macrophage-like cell in the dermis. This phenotypic switch was blocked with anti-IL-10. Mechanisms previously identified as being involved in LC activation and migration in native human skin could thus be reproduced in the in vitro constructed skin equivalent model containing functional LC. This model therefore provides a unique and relevant research tool to study human LC biology in situ under controlled in vitro conditions, and will provide a powerful tool for hazard identification, testing novel therapeutics and identifying new drug targets. - Highlights: • MUTZ-3 derived Langerhans cells integrated into skin equivalents are fully functional. • Anti-CXCL12 blocks allergen-induced MUTZ-LC migration.

  8. Protocol for a randomized controlled study of Iyengar yoga for youth with irritable bowel syndrome

    Directory of Open Access Journals (Sweden)

    Sternlieb Beth

    2011-01-01

    Full Text Available Abstract Introduction Irritable bowel syndrome affects as many as 14% of high school-aged students. Symptoms include discomfort in the abdomen, along with diarrhea and/or constipation and other gastroenterological symptoms that can significantly impact quality of life and daily functioning. Emotional stress appears to exacerbate irritable bowel syndrome symptoms suggesting that mind-body interventions reducing arousal may prove beneficial. For many sufferers, symptoms can be traced to childhood and adolescence, making the early manifestation of irritable bowel syndrome important to understand. The current study will focus on young people aged 14-26 years with irritable bowel syndrome. The study will test the potential benefits of Iyengar yoga on clinical symptoms, psychospiritual functioning and visceral sensitivity. Yoga is thought to bring physical, psychological and spiritual benefits to practitioners and has been associated with reduced stress and pain. Through its focus on restoration and use of props, Iyengar yoga is especially designed to decrease arousal and promote psychospiritual resources in physically compromised individuals. An extensive and standardized teacher-training program support Iyengar yoga's reliability and safety. It is hypothesized that yoga will be feasible with less than 20% attrition; and the yoga group will demonstrate significantly improved outcomes compared to controls, with physiological and psychospiritual mechanisms contributing to improvements. Methods/Design Sixty irritable bowel syndrome patients aged 14-26 will be randomly assigned to a standardized 6-week twice weekly Iyengar yoga group-based program or a wait-list usual care control group. The groups will be compared on the primary clinical outcomes of irritable bowel syndrome symptoms, quality of life and global improvement at post-treatment and 2-month follow-up. Secondary outcomes will include visceral pain sensitivity assessed with a standardized

  9. On-electrode autonomous current generator for multi-frequency EIT

    International Nuclear Information System (INIS)

    Jivet, I; Dragoi, B

    2008-01-01

    The paper presents an autonomous programmable current generator module for multi-frequency EIT systems. The module incorporates all stages from the sine wave generation with frequency and amplitude tuning, D/A converter and filter, a high output resistance voltage-to-current converter to the associated digital communication and control. The paper presents in depth the original digital quadrature signal generator and the output current generator with a high resistance. The other main blocks of the design use current practice specifications, since recent technological solutions proposed in the literature were found appropriate. The proposed signal generator circuit, characterized by a very low complexity, is analyzed in its capacity to produce multiple accurate signals up to 1 MHz in frequency. The precision output current source uses a modified current conveyor of type CCII with a high output resistance and low distortion. The output current frequency spectrum and linearity parameters obtained in the simulations are also described. The simulation results indicate a good linearity and high output resistance with an acceptable output voltage swing. The calculated performance parameters are validated with simulations, and future work for the prototype fabrication of the IC is outlined

  10. On the application of frequency selective common mode feedback for multifrequency EIT.

    Science.gov (United States)

    Langlois, Peter J; Wu, Yu; Bayford, Richard H; Demosthenous, Andreas

    2015-06-01

    Common mode voltages are frequently a problem in electrical impedance tomography (EIT) and other bioimpedance applications. To reduce their amplitude common mode feedback is employed. Formalised analyses of both current and voltage feedback is presented in this paper for current drives. Common mode effects due to imbalances caused by the current drives, the electrode connections to the body load and the introduction of the body impedance to ground are considered. Frequency selective narrowband common mode feedback previously proposed to provide feedback stability is examined. As a step towards multifrequency applications the use of narrowband feedback is experimentally demonstrated for two simultaneous current drives. Measured results using standard available components show a reduction of 62 dB for current feedback and 31 dB for voltage feedback. Frequencies ranged from 50 kHz to 1 MHz.

  11. Limbic Irritability, Neuronal Complexity and Smoking

    Czech Academy of Sciences Publication Activity Database

    Svetlak, M.; Bob, P.; Černík, M.; Konečný, P.; Chládek, Jan; Svrček, M.; Kukleta, M.

    2008-01-01

    Roč. 50, č. 3 (2008), s. 85 ISSN 0001-7604. [International CIANS Conference 2008: Higher Brain Functions. 28.09.2008-02.10.2008, Smolenice] Institutional research plan: CEZ:AV0Z20650511 Keywords : smoking * limbic irritability * stress * complexity * EDA Subject RIV: FH - Neurology

  12. Irritable bowel syndrome and vocational stress: individual ...

    African Journals Online (AJOL)

    Irritable bowel syndrome and vocational stress: individual psychotherapy: research. ... The goal of this study was to provide individualised psychotherapy for a sample suffering from IBS and vocational stress. ... AJOL African Journals Online.

  13. Novel vehicle based on cubosomes for ophthalmic delivery of flurbiprofen with low irritancy and high bioavailability

    Science.gov (United States)

    Han, Shun; Shen, Jin-qiu; Gan, Yong; Geng, Hai-ming; Zhang, Xin-xin; Zhu, Chun-liu; Gan, Li

    2010-01-01

    Aim: To develop a novel vehicle based on cubosomes as an ophthalmic drug delivery system for flurbiprofen (FB) to reduce ocular irritancy and improve bioavailability. Methods: FB-loaded cubosomes were prepared using hot and high-pressure homogenization. Cubosomes were then characterized by particle size, zeta potential, encapsulation efficiency, particle morphology, inner cubic structure and in vitro release. Corneal permeation was evaluated using modified Franz-type cells. Ocular irritation was then evaluated using both the Draize method and histological examination. The ocular pharmacokinetics of FB was determined using microdialysis. Results: The particle size of each cubosome formulation was about 150 nm. A bicontinuous cubic phase of cubic P-type was determined using cryo-transmission electron microscopy (cryo-TEM) observation and small angle X-ray scattering (SAXS) analysis. In vitro corneal permeation study revealed that FB formulated in cubosomes exhibited 2.5-fold (F1) and 2.0-fold (F2) increase in Papp compared with FB PBS. In the ocular irritation test, irritation scores for each group were less than 2, indicating that all formulations exhibited excellent ocular tolerance. Histological examination revealed that neither the structure nor the integrity of the cornea was visibly affected after incubation with FB cubosomes. The AUC of FB administered as FB cubosome F2 was 486.36±38.93 ng·mL−1·min·μg−1, which was significantly higher than that of FB Na eye drops (P<0.01). Compared with FB Na eye drops, the Tmax of FB cubosome F2 was about 1.6-fold higher and the MRT was also significantly longer (P<0.001). Conclusion: This novel low-irritant vehicle based on cubosomes might be a promising system for effective ocular drug delivery. PMID:20686524

  14. Non-Irritant Baby Shampoos May Cause Cataract Development

    Directory of Open Access Journals (Sweden)

    Omer Faruk Tekbas

    2008-02-01

    Full Text Available BACKGROUND: The effect of different shampoo formulations as a risk factor for cataract formation was investigated in Sprague Dawley rats in the present study. METHODS: Study was performed by using 20 rats. Two different shampoos used by adult subjects and two different baby shampoos were used in the study. Different shampoos were used in different groups for 14 days, and they were followed for changes. RESULTS: Different degree of opacities were observed in 4 (40%, 4 (40%, 5 (50%, and 6 (60% eyes in Groups A, B, C, and D, respectively. There was no statistically significant difference for formation of cataract between the groups (p>0.05. The number of irritated eyes was significantly lower (p<0.05 in groups C (10% and D (20% compared to groups A (90% and B (80%. CONCLUSION: The use of non-irritant baby shampoos does not seem to eliminate the risk of cataract formation and these should even be used more carefully as the non-irritant shampoo will have more contact with the eye. [TAF Prev Med Bull 2008; 7(1.000: 1-6

  15. A Conceptual Model of Irritability Following Traumatic Brain Injury: A Qualitative, Participatory Research Study.

    Science.gov (United States)

    Hammond, Flora M; Davis, Christine; Cook, James R; Philbrick, Peggy; Hirsch, Mark A

    2016-01-01

    Individuals with a history of traumatic brain injury (TBI) may have chronic problems with irritability, which can negatively affect their lives. (1) To describe the experience (thoughts and feelings) of irritability from the perspectives of multiple people living with or affected by the problem, and (2) to develop a conceptual model of irritability. Qualitative, participatory research. Forty-four stakeholders (individuals with a history of TBI, family members, community professionals, healthcare providers, and researchers) divided into 5 focus groups. Each group met 10 times to discuss the experience of irritability following TBI. Data were coded using grounded theory to develop themes, metacodes, and theories. Not applicable. A conceptual model emerged in which irritability has 5 dimensions: affective (related to moods and feelings); behavioral (especially in areas of self-regulation, impulse control, and time management); cognitive-perceptual (self-talk and ways of seeing the world); relational issues (interpersonal and family dynamics); and environmental (including environmental stimuli, change, disruptions in routine, and cultural expectations). This multidimensional model provides a framework for assessment, treatment, and future research aimed at better understanding irritability, as well as the development of assessment tools and treatment interventions.

  16. A non-iterative sampling approach using noise subspace projection for EIT

    International Nuclear Information System (INIS)

    Bellis, Cédric; Constantinescu, Andrei; Coquet, Thomas; Jaravel, Thomas; Lechleiter, Armin

    2012-01-01

    This study concerns the problem of the reconstruction of inclusions embedded in a conductive medium in the context of electrical impedance tomography (EIT), which is investigated within the framework of a non-iterative sampling approach. This type of identification strategy relies on the construction of a special indicator function that takes, roughly speaking, small values outside the inclusion and large values inside. Such a function is constructed in this paper from the projection of a fundamental singular solution onto the space spanned by the singular vectors associated with some of the smallest singular values of the data-to-measurement operator. The behavior of the novel indicator function is analyzed. For a subsequent implementation in a discrete setting, the quality of classical finite-dimensional approximations of the measurement operator is discussed. The robustness of this approach is also analyzed when only noisy spectral information is available. Finally, this identification method is implemented numerically and experimentally, and its efficiency is discussed on a set of, partly experimental, examples. (paper)

  17. Direct 2-D reconstructions of conductivity and permittivity from EIT data on a human chest.

    Science.gov (United States)

    Herrera, Claudia N L; Vallejo, Miguel F M; Mueller, Jennifer L; Lima, Raul G

    2015-01-01

    A novel direct D-bar reconstruction algorithm is presented for reconstructing a complex conductivity distribution from 2-D EIT data. The method is applied to simulated data and archival human chest data. Permittivity reconstructions with the aforementioned method and conductivity reconstructions with the previously existing nonlinear D-bar method for real-valued conductivities depicting ventilation and perfusion in the human chest are presented. This constitutes the first fully nonlinear D-bar reconstructions of human chest data and the first D-bar permittivity reconstructions of experimental data. The results of the human chest data reconstructions are compared on a circular domain versus a chest-shaped domain.

  18. Irritable bowel syndrome: diagnostic approaches in clinical practice

    Directory of Open Access Journals (Sweden)

    Eugene J Burbige

    2010-09-01

    Full Text Available Eugene J BurbigeDivision of Gastroenterology, Gastrointestinal and Liver Research, John Muir Medical Center, Concord, CA, USABackground: Irritable bowel syndrome (IBS, a functional gastrointestinal disorder long considered a diagnosis of exclusion, has chronic symptoms that vary over time and overlap with those of non-IBS disorders. Traditional symptom-based criteria effectively identify IBS patients but are not easily applied in clinical practice, leaving >40% of patients to experience symptoms up to 5 years before diagnosis.Objective: To review the diagnostic evaluation of patients with suspected IBS, strengths and weaknesses of current methodologies, and newer diagnostic tools that can augment current symptom-based criteria.Methods: The peer-reviewed literature (PubMed was searched for primary reports and reviews using the limiters of date (1999–2009 and English language and the search terms irritable bowel syndrome, diagnosis, gastrointestinal disease, symptom-based criteria, outcome, serology, and fecal markers. Abstracts from Digestive Disease Week 2008–2009 and reference lists of identified articles were reviewed.Results: A disconnect is apparent between practice guidelines and clinical practice. The American Gastroenterological Association and American College of Gastroenterology recommend diagnosing IBS in patients without alarm features of organic disease using symptom-based criteria (eg, Rome. However, physicians report confidence in a symptom-based diagnosis without further testing only up to 42% of the time; many order laboratory tests and perform sigmoidoscopies or colonoscopies despite good evidence showing no utility for this work-up in uncomplicated cases. In the absence of diagnostic criteria easily usable in a busy practice, newer diagnostic methods, such as stool-form examination, fecal inflammatory markers, and serum biomarkers, have been proposed as adjunctive tools to aid in an IBS diagnosis by increasing physicians

  19. Behavioral Interventions for Anger, Irritability, and Aggression in Children and Adolescents.

    Science.gov (United States)

    Sukhodolsky, Denis G; Smith, Stephanie D; McCauley, Spencer A; Ibrahim, Karim; Piasecka, Justyna B

    2016-02-01

    Anger, irritability, and aggression are among the most common reasons for child mental health referrals. This review is focused on two forms of behavioral interventions for these behavioral problems: Parent management training (PMT) and cognitive-behavioral therapy (CBT). First, we provide an overview of anger/irritability and aggression as the treatment targets of behavioral interventions, followed by a discussion of the general principles and techniques of these treatment modalities. Then we discuss our current work concerning the transdiagnostic approach to CBT for anger, irritability, and aggression. PMT is aimed at improving aversive patterns of family interactions that engender children's disruptive behavior. CBT targets deficits in emotion regulation and social problem-solving that are associated with aggressive behavior. Both forms of treatment have received extensive support in randomized controlled trials. Given that anger/irritability and aggressive behavior are common in children with a variety of psychiatric diagnoses, a transdiagnostic approach to CBT for anger and aggression is described in detail. PMT and CBT have been well studied in randomized controlled trials in children with disruptive behavior disorders, and studies of transdiagnostic approaches to CBT for anger and aggression are currently underway. More work is needed to develop treatments for other types of aggressive behavior (e.g., relational aggression) that have been relatively neglected in clinical research. The role of callous-unemotional traits in response to behavioral interventions and treatment of irritability in children with anxiety and mood disorders also warrants further investigation.

  20. Is dermatitis palmaris sicca an irritant contact dermatitis?

    Science.gov (United States)

    Chen, Fu-Juan; Liu, Zhen; Zhou, Ying; Chen, Yong-Hua; Fan, Yi-Ming

    2013-01-01

    Dermatitis palmaris sicca (DPS) is a common dry-fissured palmar dermatitis in Asian women. It may be an irritant contact dermatitis, but the immunophenotype of the cells in its infiltrate is unknown. The aim of this study was to evaluate the role of inflammatory cells in the pathogenesis of DPS. Patch testing was done in 68 patients with DPS, 87 subjects with hand eczema, and 31 healthy subjects. Immunophenotyping of cutaneous inflammatory cells was performed in 8 patients with DPS, 10 subjects with hand eczema, and 8 healthy individuals. Positive patch rates were higher in patients with DPS and those with hand eczema compared with healthy controls, but strong positive (++ or +++) reactions in DPS were fewer compared with hand eczema. Density of CD3, CD4, CD8, and CD68 cells in skin lesions of DPS and hand eczema was significantly higher than that in normal skin. Sparse CD20 cells were present only in hand eczema. Compared with hand eczema, the number of CD3, CD8, CD68, and dermal CD1a cells decreased, but epidermal CD1a cells and CD4/CD8 ratio increased in DPS. The absolute lack of CD20 cells and relative scarcity of dermal CD8 and CD1a cells in skin lesions might be insufficient to induce contact hypersensitivity, so DPS may be an irritant but not allergic contact dermatitis.

  1. Effects of a facial nerve lesion on responses in forehead microvessels to conjunctival irritation and paced breathing.

    Science.gov (United States)

    Drummond, Peter D

    2012-08-16

    To investigate parasympathetic influences on the forehead microvasculature, blood flow was monitored bilaterally in seven participants with a unilateral facial nerve lesion during conjunctival irritation with Schirmer's strips and while breathing at 0.15 Hz. Blood flow and slow-wave frequency increased on the intact side of the forehead during Schirmer's test but did not change on the denervated side. However, a 0.15 Hz vascular wave strengthened during paced breathing, particularly on the denervated side. These findings indicate that parasympathetic activity in the facial nerve increases forehead blood flow during minor conjunctival irritation, but may interfere with the 0.15 Hz vascular wave. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Clinical and Physiological Correlates of Irritability in Depression: Results from the Netherlands Study of Depression and Anxiety

    Directory of Open Access Journals (Sweden)

    Floor E. A. Verhoeven

    2011-01-01

    Full Text Available Objective. Irritable and nonirritable depressed patients differ on demographic and clinical characteristics. We investigated whether this extends to psychological and physiological measures. Method. We compared irritable and nonirritable unipolar depressed patients on symptomatology, personality, and (psychophysiological measures (cortisol, cholesterol, and heart rate variability. Symptomatology was reassessed after one year, and we also compared depressed patients who were irritable or non-irritable at both time points (Irr++ versus Irr−−. Results. Almost half (46%; N=420 of the sample was classified as irritable. These patients scored higher on depression severity, anxiety, hypomanic symptoms, and psychological variables. No differences were observed on physiological markers after correction for depression severity. The same pattern was found when comparing Irr++ and Irr−− groups. Conclusion. Irritable and non-irritable depressed patients differ on clinical and psychological variables, but not on the currently investigated physiological markers. The clinical relevance of the distinction and the significance of the hypomanic symptoms remain to be demonstrated.

  3. Piezo2: A Candidate Biomarker for Visceral Hypersensitivity in Irritable Bowel Syndrome?

    OpenAIRE

    Bai, Tao; Li, Ying; Xia, Jing; Jiang, Yudong; Zhang, Lei; Wang, Huan; Qian, Wei; Song, Jun; Hou, Xiaohua

    2017-01-01

    Background/Aims Currently, there exists no biomarker for visceral hypersensitivity in irritable bowel syndrome (IBS). Piezo proteins have been proven to play an important role in the mechanical stimulation to induce visceral pain in other tissues and may also be a biomarker candidate. The aim of this study was to test the expressions of Piezo1 and Piezo2 proteins in the intestinal epithelial cells from different intestinal segments and to explore the correlation between Piezo proteins express...

  4. Impact of psychological stress on irritable bowel syndrome.

    Science.gov (United States)

    Qin, Hong-Yan; Cheng, Chung-Wah; Tang, Xu-Dong; Bian, Zhao-Xiang

    2014-10-21

    Psychological stress is an important factor for the development of irritable bowel syndrome (IBS). More and more clinical and experimental evidence showed that IBS is a combination of irritable bowel and irritable brain. In the present review we discuss the potential role of psychological stress in the pathogenesis of IBS and provide comprehensive approaches in clinical treatment. Evidence from clinical and experimental studies showed that psychological stresses have marked impact on intestinal sensitivity, motility, secretion and permeability, and the underlying mechanism has a close correlation with mucosal immune activation, alterations in central nervous system, peripheral neurons and gastrointestinal microbiota. Stress-induced alterations in neuro-endocrine-immune pathways acts on the gut-brain axis and microbiota-gut-brain axis, and cause symptom flare-ups or exaggeration in IBS. IBS is a stress-sensitive disorder, therefore, the treatment of IBS should focus on managing stress and stress-induced responses. Now, non-pharmacological approaches and pharmacological strategies that target on stress-related alterations, such as antidepressants, antipsychotics, miscellaneous agents, 5-HT synthesis inhibitors, selective 5-HT reuptake inhibitors, and specific 5-HT receptor antagonists or agonists have shown a critical role in IBS management. A integrative approach for IBS management is a necessary.

  5. Acute irritant threshold correlates with barrier function, skin hydration and contact hypersensitivity in atopic dermatitis and rosacea.

    Science.gov (United States)

    Darlenski, Razvigor; Kazandjieva, Jana; Tsankov, Nikolai; Fluhr, Joachim W

    2013-11-01

    The aim of the study was to disclose interactions between epidermal barrier, skin irritation and sensitization in healthy and diseased skin. Transepidermal water loss (TEWL) and stratum corneum hydration (SCH) were assessed in adult patients with atopic dermatitis (AD), rosacea and healthy controls. A 4-h patch test with seven concentrations of sodium lauryl sulphate was performed to determine the irritant threshold (IT). Contact sensitization pattern was revealed by patch testing with European baseline series. Subjects with a lower IT had higher TEWL values and lower SCH. Subjects with positive allergic reactions had significantly lower IT. In AD, epidermal barrier deterioration was detected on both volar forearm and nasolabial fold, while in rosacea, impeded skin physiology parameters were observed on the facial skin only, suggesting that barrier impediment is restricted to the face in rosacea, in contrast with AD where the abnormal skin physiology is generalized. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Flow-volume loops measured with electrical impedance tomography in pediatric patients with asthma.

    Science.gov (United States)

    Ngo, Chuong; Dippel, Falk; Tenbrock, Klaus; Leonhardt, Steffen; Lehmann, Sylvia

    2018-05-01

    Electrical impedance tomography (EIT) provides information on global and regional ventilation during tidal breathing and mechanical ventilation. During forced expiration maneuvers, the linearity of EIT and spirometric data has been documented in healthy persons. The present study investigates the potential diagnostic use of EIT in pediatric patients with asthma. EIT and spirometry were performed in 58 children with asthma (average age ± SD: 11.86 ± 3.13 years), and 58 healthy controls (average age ± SD: 12.12 ± 2.9 years). The correlation between EIT data and simultaneously acquired spirometric data were tested for FEV 1 , FEV 0.5 , MEF 75 , MEF 50 , and MEF 25 . Binary classification tests were performed for the EIT-derived Tiffeneau index FEV 1 /FVC and the bronchodilator test index ΔFEV 1 . Average flow-volume (FV) loops were generated for patients with pathologic spirometry to demonstrate the feasibility of EIT for graphic diagnosis of asthma. Spirometry and global EIT-based FV loops showed a strong correlation (P  0.9 in FEV 1 and FEV 0.5 ). In all criteria, the binary classification tests yielded high specificity (>93%), a high positive predictive value (≥75%) and a high negative predictive value (>80%), while sensitivity was higher in ΔFEV 1 (86.67%) and lower in FEV 1 /FVC (25% and 35.29%). A typical concave shape of the EIT-derived average FV loops was observed for asthmatic children with improvement after bronchospasmolysis. Global FV loops derived from EIT correlate well with spirometry. Positive bronchospasmolysis can be observed in EIT-derived FV loops. Flow-volume loops originated from EIT have a potential to visualize pulmonary function. © 2018 Wiley Periodicals, Inc.

  7. Group hypnotherapy for irritable bowel syndrome with long-term follow-up.

    Science.gov (United States)

    Gerson, Charles D; Gerson, Jessica; Gerson, Mary-Joan

    2013-01-01

    This study tested whether group gut-focused hypnotherapy would improve irritable bowel syndrome (IBS). Several possible outcome predictors were also studied. Before treatment, 75 patients completed a Symptom Severity Scale, a Mind-Body attribution questionnaire, and a Quality of Relationship Inventory (QRI). The symptom scale was completed posttreatment, 3, 6, and 12 months later. There was significant symptom reduction at each data point (p hypnotherapy, while attribution of symptoms to mind (emotional) causation was inversely correlated (p = .0056). The authors conclude that group hypnotherapy is effective in patients with IBS.

  8. Design of all-optical memory cell using EIT and lasing without inversion phenomena in optical micro ring resonators

    Science.gov (United States)

    Pasyar, N.; Yadipour, R.; Baghban, H.

    2017-07-01

    The proposed design of the optical memory unit cell contains dual micro ring resonators in which the effect of lasing without inversion (LWI) in three-level nano particles doped over the optical resonators or integrators as the gain segment is used for loss compensation. Also, an on/off phase shifter based on electromagnetically induced transparency (EIT) in three-level quantum dots (QDs) has been used for data reading at requested time. Device minimizing for integrated purposes and high speed data storage are the main advantages of the optical integrator based memory.

  9. An in vitro model for detecting skin irritants: methyl green-pyronine staining of human skin explant cultures

    NARCIS (Netherlands)

    Jacobs, J. J. L.; Lehé, C.; Cammans, K. D. A.; Das, P. K.; Elliott, G. R.

    2002-01-01

    We evaluated the potential of human organotypic skin explant cultures (hOSECs) for screening skin irritants. Test chemicals were applied to the epidermis of the skin explants which were incubated for 4, 24 or 48 h in tissue culture medium. A decrease in epidermal RNA staining, visualised in frozen

  10. Omega-3 fatty acids decreased irritability of patients with bipolar disorder in an add-on, open label study

    Directory of Open Access Journals (Sweden)

    Baldassano Claudia F

    2005-02-01

    Full Text Available Abstract This is a report on a 37-patient continuation study of the open ended, Omega-3 Fatty Acid (O-3FA add-on study. Subjects consisted of the original 19 patients, along with 18 new patients recruited and followed in the same fashion as the first nineteen. Subjects carried a DSM-IV-TR diagnosis of Bipolar Disorder and were visiting a Mood Disorder Clinic regularly through the length of the study. At each visit, patients' clinical status was monitored using the Clinical Monitoring Form. Subjects reported on the frequency and severity of irritability experienced during the preceding ten days; frequency was measured by way of percentage of days in which subjects experienced irritability, while severity of that irritability was rated on a Likert scale of 1 – 4 (if present. The irritability component of Young Mania Rating Scale (YMRS was also recorded quarterly on 13 of the 39 patients consistently. Patients had persistent irritability despite their ongoing pharmacologic and psychotherapy. Omega-3 Fatty Acid intake helped with the irritability component of patients suffering from bipolar disorder with a significant presenting sign of irritability. Low dose (1 to 2 grams per day, add-on O-3FA may also help with the irritability component of different clinical conditions, such as schizophrenia, borderline personality disorder and other psychiatric conditions with a common presenting sign of irritability.

  11. Diet in irritable bowel syndrome

    OpenAIRE

    El-Salhy, Magdy; Gundersen, Doris Irene

    2015-01-01

    Irritable bowel syndrome (IBS) is a common chronic gastrointestinal disorder that is characterized by intermittent abdominal pain/discomfort, altered bowel habits and abdominal bloating/distension. This review aimed at presenting the recent developments concerning the role of diet in the pathophysiology and management of IBS. There is no convincing evidence that IBS patients suffer from food allergy/intolerance, and there is no evidence that gluten causes the debated new diagnosis of non-coel...

  12. Irritable bowel syndrome: Is it "irritable brain" or "irritable bowel"?

    Directory of Open Access Journals (Sweden)

    Susanta Kumar Padhy

    2015-01-01

    Full Text Available Irritable bowel syndrome (IBS has been recognized as one of the most common and best studied disorders among the group of functional gastrointestinal disorders. It is a functional bowel disorder in which abdominal pain or discomfort is associated with defecation or a change in bowel habit. In the Western world, IBS appears to affect up to 20% of the population at any given time but in Asian countries, the median value of IBS prevalence defined by various criteria ranges between 6.5% and 10.1%, and community prevalence of 4% is found in North India. Those attending gastroenterology clinics represent only the tip of the iceberg. The disorder substantially impairs the quality of life, and the overall health-care costs are high. IBS has therefore gained increased attention from clinicians, researchers, and pharmaceutical industries. It is often frustrating to both patients and physicians as the disease is usually chronic in nature and difficult to treat. However, the understanding of IBS has been changing from time to time and still most of its concepts are unknown. In this review we have discussed, debated, and synthesized the evidence base, focusing on underlying mechanisms in the brain and bowel. We conclude that it is both brain and bowel mechanisms that are responsible. The clinical implication of such mechanisms is discussed.

  13. PAINFUL IRRITABLE-BOWEL-SYNDROME AND SIGMOID CONTRACTIONS

    NARCIS (Netherlands)

    RITSEMA, GH; THIJN, CJP

    Fifteen patients with abdominal pain compatible with the irritable bowel syndrome (IBS) were examined by barium enema and pressure recording. Strong circular contractions of the sigmoid colon and pressure recordings correlated with the characteristic pain in 13 of the 15 patients. In 15 control

  14. Role of alimentation in irritable bowel syndrome

    NARCIS (Netherlands)

    Dapoigny, M.; Stockbrügger, R. W.; Azpiroz, F.; Collins, S.; Coremans, G.; Müller-Lissner, S.; Oberndorff, A.; Pace, F.; Smout, A.; Vatn, M.; Whorwell, P.

    2003-01-01

    BACKGROUND: Different food items are made responsible for irritable bowel syndrome (IBS) symptoms, but the physiopathology of IBS remains unclear. AIMS: During a meeting in Nice, France, experts of the European Working Team of the IBiS Club discussed selected data regarding the relationships between

  15. The gendered impact of Irritable Bowel Syndrome: a qualitative study of patients' experiences.

    Science.gov (United States)

    Björkman, Ida; Dellenborg, Lisen; Ringström, Gisela; Simrén, Magnus; Jakobsson Ung, Eva

    2014-06-01

    The aim of the study was to explore the impact of irritable bowel syndrome on daily life from a gender perspective. Irritable bowel syndrome is a common functional disorder, characterized by abdominal pain, diarrhoea and/or constipation. Sufferers experience negative emotions due to unpredictable symptoms and sometimes feel trivialized by healthcare professionals. The sufferers' experience of living with this disorder has never been explored from a gender perspective. A qualitative, interpretative method was used. A qualitative, hermeneutic method was applied. Interviews were conducted with 19 patients in 2011 and analysed in a constructionist gender framework. Constructionist gender theory views gender and identity as cultural constructs that develop through interplay between the individual and his/her social context and cultural norms. The main theme to emerge from the interviews was as follows: 'A normative framework of femaleness and maleness leads to suffering for persons with irritable bowel syndrome'. This consists of three interwoven themes: 'Being forced to abandon gender illusions'; 'Being forced to transcend taboos' and 'Reinforced suffering in healthcare encounters'. Men demonstrated masculinity by stressing the importance of being solid family providers while women spoke of nurturing and relational responsibilities in line with traditional notions of femininity. The experience of living with irritable bowel syndrome differs between men and women due to differing societal expectations, life situation and the everyday construction of gender identities. Gender stereotyping by healthcare professionals perpetuates rather than alleviates the suffering experienced by men and women with irritable bowel syndrome. In healthcare encounters, women risk being trivialized and men risk being overlooked due to the 'female health concern' label attached to irritable bowel syndrome. © 2013 John Wiley & Sons Ltd.

  16. Efficacy and Tolerability of Pharmacotherapy Options for the Treatment of Irritability in Autistic Children

    Directory of Open Access Journals (Sweden)

    Eiji Kirino

    2014-01-01

    Full Text Available Children with autism have a high rate of irritability and aggressive symptoms. Irritability or self-injurious behavior can result in significant harm to those affected, as well as to marked distress for their families. This paper provides a literature review regarding the efficacy and tolerability of pharmacotherapy for the treatment of irritability in autistic children. Although antipsychotics have not yet been approved for the treatment of autistic children by many countries, they are often used to reduce symptoms of behavioral problems, including irritability, aggression, hyperactivity, and panic. However, among antipsychotics, the Food and Drug Administration has approved only risperidone and aripiprazole to treat irritability in autism. Among atypical antipsychotics, olanzapine and quetiapine are limited in their use for autism spectrum disorders in children because of high incidences of weight gain and sedation. In comparison, aripiprazole and ziprasidone cause less weight gain and sedation. However, potential QTc interval prolongation with ziprasidone has been reported. Contrary to ziprasidone, no changes were evident in the QT interval in any of the trials for aripiprazole. However, head-to-head comparison studies are needed to support that aripiprazole may be a promising drug that can be used to treat irritability in autistic children. On the other hand, risperidone has the greatest amount of evidence supporting it, including randomized controlled trials; thus, its efficacy and tolerability has been established in comparison with other agents. Further studies with risperidone as a control drug are needed.

  17. Contact irritant responses of Aedes aegypti Using sublethal concentration and focal application of pyrethroid chemicals.

    Directory of Open Access Journals (Sweden)

    Hortance Manda

    Full Text Available BACKGROUND: Previous studies have demonstrated contact irritant and spatial repellent behaviors in Aedes aegypti following exposure to sublethal concentrations of chemicals. These sublethal actions are currently being evaluated in the development of a push-pull strategy for Ae. aegypti control. This study reports on mosquito escape responses after exposure to candidate chemicals for a contact irritant focused push-pull strategy using varying concentrations and focal application. METHODS: Contact irritancy (escape behavior, knockdown and 24 hour mortality rates were quantified in populations of female Ae. aegypti under laboratory conditions and validated in the field (Thailand and Peru using experimental huts. Evaluations were conducted using varying concentrations and treatment surface area coverage (SAC of three pyrethroid insecticides: alphacypermethrin, lambacyhalothrin and deltamethrin. RESULTS: Under laboratory conditions, exposure of Ae. aegypti to alphacypermethrin using the standard field application rate (FAR resulted in escape responses at 25% and 50% SAC that were comparable with escape responses at 100% SAC. Significant escape responses were also observed at <100% SAC using ½FAR of all test compounds. In most trials, KD and 24 hour mortality rates were higher in mosquitoes that did not escape than in those that escaped. In Thailand, field validation studies indicated an early time of exit (by four hours and 40% increase in escape using ½FAR of alphacypermethrin at 75% SAC compared to a matched chemical-free control. In Peru, however, the maximum increase in Ae. aegypti escape from alphacypermethrin-treated huts was 11%. CONCLUSIONS/SIGNIFICANCE: Results presented here suggest a potential role for sublethal and focal application of contact irritant chemicals in an Ae. aegypti push-pull strategy to reduce human-vector contact inside treated homes. However, the impact of an increase in escape response on dengue virus transmission is

  18. Eating, Diet, and Nutrition for Irritable Bowel Syndrome

    Science.gov (United States)

    ... Causes Diagnosis Treatment Eating, Diet, & Nutrition Clinical Trials Eating, Diet, & Nutrition for Irritable Bowel Syndrome How can ... Some people with IBS have more symptoms after eating gluten, even though they do not have celiac ...

  19. In vivo assessment of cytological changes by means of reflectance confocal microscopy - demonstration of the effect of topical vitamin E on skin irritation caused by sodium lauryl sulfate.

    Science.gov (United States)

    Casari, Alice; Farnetani, Francesca; De Pace, Barbara; Losi, Amanda; Pittet, Jean-Christophe; Pellacani, Giovanni; Longo, Caterina

    2017-03-01

    Irritant contact dermatitis is caused by skin barrier damage. Vitamin E is an antioxidant that is commonly used in cosmetics to prevent photo-damage. To show the usefulness of reflectance confocal microscopy in the assessment of irritant skin damage caused by sodium lauryl sulfate (SLS) and of the protective action of vitamin E applied prior to skin irritation. Ten healthy volunteers were enrolled. Irritation was induced by the application of a patch test containing SLS 5% aq. for 24 h. Three sites were compared: one site on which a product with vitamin E was applied before SLS treatment, one site on which the same product was applied after SLS treatment, and one control site (SLS only). Each site was evaluated with reflectance confocal microscopy, providing in vivo tissue images at nearly histological resolution. We also performed a computerized analysis of the VivaStack® images. Reflectance confocal microscopy is able to identify signs of skin irritation and the preventive effect of vitamin E application. Reflectance confocal microscopy is useful in the objective assessment of irritative skin damage. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions.

    Science.gov (United States)

    Zhang, Jie; Patterson, Robert

    2014-01-01

    This study is aimed at investigating the variability in resistivity changes in the lung region as a function of air volume, electrode plane and body position. Six normal subjects (33.8 ± 4.7 years, range from 26 to 37 years) were studied using the Sheffield Electrical Impedance Tomography (EIT) portable system. Three transverse planes at the level of second intercostal space, the level of the xiphisternal joint, and midway between upper and lower locations were chosen for measurements. For each plane, sixteen electrodes were uniformly positioned around the thorax. Data were collected with the breath held at end expiration and after inspiring 0.5, 1.0, or 1.5 liters of air from end expiration, with the subject in both the supine and sitting position. The average resistivity change in five regions, two 8x8 pixel local regions in the right lung, entire right, entire left and total lung regions, were calculated. The results show the resistivity change averaged over electrode positions and subject positions was 7-9% per liter of air, with a slightly larger resistivity change of 10 % per liter air in the lower electrode plane. There was no significant difference (p>0.05) between supine and sitting. The two 8x8 regions show a larger inter individual variability (coefficient of variation, CV, is from 30% to 382%) compared to the entire left, entire right and total lung (CV is from 11% to 51%). The results for the global regions are more consistent. The large inter individual variability appears to be a problem for clinical applications of EIT, such as regional ventilation. The variability may be mitigated by choosing appropriate electrode plane, body position and region of interest for the analysis.

  1. Evaluation of seven in vitro alternatives for ocular safety testing.

    Science.gov (United States)

    Bruner, L H; Kain, D J; Roberts, D A; Parker, R D

    1991-07-01

    Seven in vitro assays were evaluated to determine if any were useful as screening procedures in ocular safety assessment. Seventeen test materials (chemicals, household cleaners, hand soaps, dishwashing liquids, shampoos, and liquid laundry detergents) were tested in each assay. In vivo ocular irritation scores for the materials were obtained from existing rabbit low volume eye test (LVET) data. The seven assays evaluated included the silicon microphysiometer (SM), luminescent bacteria toxicity test (LBT), neutral red assay (NR), total protein assay (TP), Tetrahymena thermophila motility assay (TTMA), bovine eye/chorioallantoic membrane assay (BE/CAM), and the EYTEX system (ETS). For the seventeen materials used in this study there was a significant correlation between the in vivo irritant potential and in vitro data for all the tests except the EYTEX System (SM, r = -0.87; LBT, r = -0.91; NR, r = -0.85; TTMA, r = 0.78; TP, r = -0.86; ETS, r = 0.29). The irritation classifications provided by the BE/CAM also did not correspond with the actual in vivo irritancy potential of the test materials. The result of this study suggested it may be possible to classify materials into broad irritancy categories with some of the assays. This would allow their use as screens prior to limited in vivo confirmation in the ocular safety assessment process.

  2. Effectiveness of probiotics in irritable bowel syndrome: Updated systematic review with meta-analysis

    Science.gov (United States)

    Didari, Tina; Mozaffari, Shilan; Nikfar, Shekoufeh; Abdollahi, Mohammad

    2015-01-01

    AIM: To investigate the efficacy of probiotics in irritable bowel syndrome (IBS) patients. METHODS: PubMed, Cochrane library, Scopus, Google Scholar, and Clinicaltrial.gov databases were searched for literature published between September 2007 and December 2013. The applied Mesh terms were “probiotics,” “irritable bowel syndrome,” and “irritable bowel syndrome treatment.” The collected data contained24 clinical trials, of which 15 were eligible for meta-analysis and nine were reviewed systematically. All studies were randomized placebo-controlled trials in patients with IBS that investigated the efficacy of probiotics in IBS improvement. The Jadad score was used to assess the methodological quality of trials. The quality scale ranges from 0 to 5 points, with a score ≤ 2 indicating a low quality report, and a score of ≥ 3 indicating a high quality report. Relative risk (RR), standardized effect size, and 95%CI were calculated using the DerSimonian-Laird method. The Cochran Q test was used to test heterogeneity with P probiotics to placebo was 1.96 (95%CI: 1.14-3.36; P = 0.01). RR of responders to therapies based on a global symptom score in IBS patients for two included trials comparing probiotics with placebo was 2.43 (95%CI: 1.13-5.21; P = 0.02). For adequate improvement of general symptoms in IBS patients, the RR of seven included trials (six studies) comparing probiotics with placebo was 2.14 (95%CI: 1.08-4.26; P = 0.03). Distension, bloating, and flatulence were evaluated using an IBS severity scoring system in three trials (two studies) to compare the effect of probiotic therapy in IBS patients with placebo, the standardized effect size of mean differences for probiotics therapy was -2.57 (95%CI: -13.05--7.92). CONCLUSION: Probiotics reduce pain and symptom severity scores. The results demonstrate the beneficial effects of probiotics in IBS patients in comparison with placebo. PMID:25780308

  3. Experimental study on skin irritation of bone spur powder on rabbit

    Science.gov (United States)

    Ma, Zhenzhen; Zhang, Xuhui; Hao, Shaojun; Shen, Huiling; Wang, Huamin; Ji, Xianghui; Zhang, Zhengchen; Huang, Youling

    2018-04-01

    To observe the effect of bone powder of rabbit skin, provide the basis for the safety of clinical use of bone powder, 24 rabbits were randomly divided into 6 groups, complete skin test and damaged skin test each divided into 3 groups (n=4), high, low, 3 doses tested daily administered 1 times, continuous administration for 7 days, in 24 hours after the last administration of drug residues, wash with warm water, the removal of L hours after drug for 24 hours, 48 hours, 72 hours and seventh days, observed and recorded to apply position before administration and administration during the skin no erythema and edema, and observe the smear Parts of any pigmentation, bleeding, rough skin or thin skin etc., record the occurrence time and duration time. Through comparative observation, intact skin group before administration and dosing period, there were no erythema and edema, pigmentation, bleeding, rough skin or thin skin etc., there is no difference with the control group; the damaged skin group after administration of 1 to 5 days, each rabbit skin there are different degrees of erythema and edema, especially to skin injury after 24-48 hours is obvious, 2 days (48 hours) after 4 days gradually reduced, significantly subsided after 6 days, erythema and edema phenomenon subsided completely, not out of blood, pigmentation, rough skin or thin skin and so on. The bone spur powder has no irritation on the intact skin of rabbits. The bone spur powder has moderate irritation on the damaged skin of rabbits, but after 48 hours, the stimulation reaction subsided spontaneously, which is caused by the inflammatory reaction caused by skin injury, rather than the medication. The bone spur powder is safe for clinical use.

  4. Putative skin-protective formulations in preventing and/or inhibiting experimentally-produced irritant and allergic contact dermatitis.

    Science.gov (United States)

    Zhai, H; Willard, P; Maibach, H I

    1999-10-01

    The effectiveness of skin protective formulations was evaluated in a previously-described in vivo human model. All formulations failed to inhibit ammonium hydroxide and urea irritation. Only paraffin wax in cetyl alcohol statistically (plauryl sulfate irritation. Paraffin wax in cetyl alcohol was quantitatively the most effective formulation. These results suggest that some formulations may provide protective effects against certain, but not all, irritants or allergens.

  5. A single exposure to photochemical smog causes airway irritation and cardiac dysrhythmia in mice

    Science.gov (United States)

    The data presented here shows that a single exposure to photochemical smog causes airway irritation and cardiac dysrhythmia in mice. Smog, which is a complex mixture of particulate matter and gaseous irritants (ozone, sulfur dioxide, reactive aldehydes), as well as components whi...

  6. Small intestinal bacterial overgrowth prevalence in celiac disease patients is similar in healthy subjects and lower in irritable bowel syndrome patients.

    Science.gov (United States)

    Lasa, J S; Zubiaurre, I; Fanjul, I; Olivera, P; Soifer, L

    2015-01-01

    Untreated celiac disease has traditionally been linked to a greater risk for small intestinal bacterial overgrowth, but the existing evidence is inconclusive. To compare the prevalence of small intestinal bacterial overgrowth in subjects with celiac disease compared with control subjects and patients with irritable bowel syndrome. The study included 15 untreated celiac disease patients, 15 subjects with irritable bowel syndrome, and 15 healthy controls. All enrolled patients underwent a lactulose breath test measuring hydrogen and methane. Small intestinal bacterial overgrowth was defined according to previously published criteria. No differences were found in relation to age or sex. The prevalence of small intestinal bacterial overgrowth was similar between the celiac disease patients and the controls (20 vs. 13.33%, P=NS), whereas it was higher in patients with irritable bowel syndrome (66.66%, Pintestinal bacterial overgrowth between the untreated celiac disease patients and healthy controls. Copyright © 2015 Asociación Mexicana de Gastroenterología. Published by Masson Doyma México S.A. All rights reserved.

  7. The combined diagnosis of allergic and irritant contact dermatitis in a retrospective cohort of 1000 consecutive patients with occupational contact dermatitis.

    Science.gov (United States)

    Schwensen, Jakob F; Menné, Torkil; Johansen, Jeanne D

    2014-12-01

    The diagnosis of combined allergic and irritant contact dermatitis is an accepted subdiagnosis for hand dermatitis, and it is often considered in a patient with contact dermatitis, a positive and relevant patch test result, and wet work exposure. We therefore hypothesize that it is arbitrary for wet work exposure to be taken into consideration in a patient with newly diagnosed relevant contact allergy. Furthermore, an overestimation of the diagnosis will probably occur if the criteria for wet work exposure are applied correctly, as many occupations have an element of wet work. To find the statistically expected number of combined allergic and irritant contact dermatitis cases in 1000 patients, and to evaluate the diagnostic criteria for the diagnosis. One thousand consecutive patients with occupational contact dermatitis from a hospital unit in Denmark were assessed. The expected number of cases with the diagnosis of combined allergic and irritant contact dermatitis was 0.33%, as compared with the observed number of 6.4%. Females occupied in wet occupations were often diagnosed with combined allergic and irritant contact dermatitis (p contact dermatitis should be used critically to avoid misclassification, and possible criteria for the diagnosis are proposed. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Immunogenicity, immunological cross reactivity and non-specific irritant properties of the exudate gums, arabic, karaya and tragacanth.

    Science.gov (United States)

    Strobel, S; Ferguson, A; Anderson, D M

    1986-01-01

    An animal model has been used to investigate the immunogenicity and non-specific irritant properties of exudate gums. The materials studied were four preparations of gum arabic (Acacia spp.), two of gum karaya (Sterculia spp.), two of gum tragacanth (Astralagus spp.) and a residue obtained after ethanol extraction of gum arabic. Groups of animals were intradermally immunized with the gum in complete Freund's adjuvant. Serum antibody levels were measured by an ELISA technique and delayed hypersensitivity responses by a footpad swelling test. Antigenic cross-reactivity within each gum species was tested in a crossover fashion. All gum preparations elicited systemic immune responses after immunization. Further processing reduced immunogenicity, although there was no evidence that systemic immunity to these complex polysaccharide antigens responses could be completely abolished by processing or purification. The ethanolic extract, and some of the gum preparations, particularly tragacanth and karaya, caused considerable footpad swelling when injected intradermally. It is concluded that processing and awareness of subspecies differences can reduce the inherent immunogenicity and potential irritant effects of exudate gums.

  9. How Probiotic Reduce Symptoms of Irritable Bowel Syndrome?

    Directory of Open Access Journals (Sweden)

    M Khalesi

    2014-04-01

    Full Text Available Introduction: Irritable bowel syndrome (IBS is a common gastrointestinal disorder in children that may lead to anxiety, frequent physician visits and school absenteeism. The aim of this study is to reviewe effects of probiotic for irritable bowel syndrome.   Materials and Methods: This study review articles about probiotic for irritable bowel syndrome in pubmed and google scholar.   Results: Multiple etiologic factors were suggested for IBS, including psychosocial factors, altered gastrointestinal motility,   malfermentation of food residues and changes in the intestinal micro flora. It is reported that patients with IBS have a great homogeneity in the fecal flora with a decrease in lactobacilli, coliforms and bifidobacteria in comparison to healthy individuals. The beneficial effects of probiotics in IBS could be explained by increasing the mass of beneficial bacteria such as lactobacilli strains in the digestive tract, decreasing bacterial overgrowth in the small bowel. Recently it was also demonstrated that some lactobacilli strains may modulate intestinal pain attacks by inducing the expression of μ-opioid and cannabinoid receptors in the intestinal epithelial cells. Probiotics can also reinforce the intestinal mucosal barrier and normalize the motility of the digestive tract and its visceral sensitivity and reversing the imbalance between the pro- and anti-inflammatory cytokines so that suggested as a therapeutic option for IBS.   Conclusion: Probiotic has been suggested as a therapeutic option for IBS by modulation pathophysiologic events in these patients. Keyword: Probiotic, IBS, Children.

  10. The dynamic quiet solar corona: 4 days of joint observing with MDI and EIT

    Science.gov (United States)

    Schrijver, C. J.; Shine, R. A.; Hurlburt, N. E.; Tarbell, T. D.; Lemen, J. R.

    1997-01-01

    The analysis of a sequence of joint extreme ultraviolet imaging telescope (EIT) Fe XII and Michelson Doppler imager (MDI) magnetogram observations of the quiet sun near disk center is presented. It was found that: all the emerging flux above the threshold of approximately 10(sup 17) Mx is associated with enhanced coronal emissions; loop systems between the polarities in ephemeral regions remain visible up to separations of 10000 up to 30000 km; brightenings between approaching opposite polarity network concentrations form when the concentrations are between 5000 and 25000 km apart, and that faint connections up to 40000 km in length form as sets of concentrations of the same polarity coagulate. The coronal emission over patches of the quiet sun depends on the total flux in connected concentrations, on their distance and on the positions and strengths of neighboring concentrations.

  11. Visceral hypersensitivity in Irritable Bowel Syndrome:pathophysiological mechanisms

    NARCIS (Netherlands)

    Kerckhoffs, A.P.M.

    2009-01-01

    Irritable Bowel Syndrome (IBS) is a functional bowel disease characterized by abdominal pain or discomfort associated with a disordered defecation. No unique pathophysiological mechanism has been identified. It is most likely a multifactorial disease involving alterations in intestinal microbiota

  12. Slight respiratory irritation but not inflammation in mice exposed to (1→3-β-D-glucan aerosols

    Directory of Open Access Journals (Sweden)

    A. Korpi

    2003-01-01

    Full Text Available Airway irritation effects after single and repeated inhalation exposures to aerosols of β-glucan (grifolan were investigated in mice. In addition, the effects on serum total immunoglobulin E (IgE production and histopathological inflammation in the respiratory tract were studied. The β-glucan aerosols provoked slight sensory irritation in the airways, but the response was not concentration dependent at the levels studied. Slight pulmonary irritation was observed after repeated exposures. No effect was found on the serum total IgE levels, and no signs of inflammation were seen in the airways 6 h after the final exposure. The results suggest that, irrespective of previous fungal sensitization of the animals, inhaled β-glucan may cause symptoms of respiratory tract irritation but without apparent inflammation. Respiratory tract irritation reported after inhalation of fungi may not be entirely attributed to β-glucan.

  13. Treatment of abdominal pain in irritable bowel syndrome

    NARCIS (Netherlands)

    Vanuytsel, Tim; Tack, Jan F.; Boeckxstaens, Guy E.

    2014-01-01

    Functional abdominal pain in the context of irritable bowel syndrome (IBS) is a challenging problem for primary care physicians, gastroenterologists and pain specialists. We review the evidence for the current and future non-pharmacological and pharmacological treatment options targeting the central

  14. Wearable sensors for patient-specific boundary shape estimation to improve the forward model for electrical impedance tomography (EIT) of neonatal lung function.

    Science.gov (United States)

    Khor, Joo Moy; Tizzard, Andrew; Demosthenous, Andreas; Bayford, Richard

    2014-06-01

    Electrical impedance tomography (EIT) could be significantly advantageous to continuous monitoring of lung development in newborn and, in particular, preterm infants as it is non-invasive and safe to use within the intensive care unit. It has been demonstrated that accurate boundary form of the forward model is important to minimize artefacts in reconstructed electrical impedance images. This paper presents the outcomes of initial investigations for acquiring patient-specific thorax boundary information using a network of flexible sensors that imposes no restrictions on the patient's normal breathing and movements. The investigations include: (1) description of the basis of the reconstruction algorithms, (2) tests to determine a minimum number of bend sensors, (3) validation of two approaches to reconstruction and (4) an example of a commercially available bend sensor and its performance. Simulation results using ideal sensors show that, in the worst case, a total shape error of less than 6% with respect to its total perimeter can be achieved.

  15. Surgery-Related Contact Dermatitis: A Review of Potential Irritants and Allergens.

    Science.gov (United States)

    Cook, Kevin A; Kelso, John M

    Surgical procedures utilize an increasing number of medical products including antiseptics, anesthetics, gloves, suture materials, tissue adhesives, topical antibiotics, and bandages. Many of these products have irritant potential. Allergic contact dermatitis has also been reported. This review covers preoperative, operative, and postoperative exposures that may result in contact dermatitis. Testing with standard patch panels such as T.R.U.E. Test and the North American Contact Dermatitis Group 65 allergen series does not evaluate for all relevant contactants. A thorough understanding of potential exposures is vital to effectively evaluate a patient with surgery-related contact dermatitis. A systematic approach is needed to ensure that standard patch panels and supplementary patches adequately address each encountered contactant. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  16. THE PREVALENCE AND CLINICAL CHARACTERISTICS OF PRIMARY HEADACHE IN IRRITABLE BOWEL SYNDROME: a subgroup of the functional somatic syndromes

    Directory of Open Access Journals (Sweden)

    Rosa LS SOARES

    2013-12-01

    Full Text Available Context The irritable bowel syndrome and primary headache are two chronic diseases characterized by symptoms of recurring pain and affect approximately 10%-20% of the general population. Objectives To study the prevalence of primary headache in volunteers with irritable bowel syndrome in a Brazilian urban community. Methods It was evaluated the prevalence of primary headache associated with irritable bowel syndrome in adult volunteers 330 no patients.The protocol included the Rome III criteria, international classification of Headaches, later divided into four groups: I- Irritable bowel syndrome (n = 52, II- Primary headache (n = 45, III-Irritable bowel syndrome (n = 26 and headache, and IV- Controls (207. Results We not found significant difference in the average age of the four groups and the diagnosis of irritable bowel syndrome, primary headache and their association was more frequent in females. The frequent use of analgesics was greater in groups II and III. Conclusion Our results suggest that irritable bowel syndrome and primary headache are also common in third world countries. The frequency in use of analgesics in association between the two entities was relevant. The identification of irritable bowel syndrome patients with different clinical sub-types could improve the therapeutics options and the prevention strategies.

  17. Ventilation distribution measured with EIT at varying levels of pressure support and Neurally Adjusted Ventilatory Assist in patients with ALI.

    Science.gov (United States)

    Blankman, Paul; Hasan, Djo; van Mourik, Martijn S; Gommers, Diederik

    2013-06-01

    The purpose of this study was to compare the effect of varying levels of assist during pressure support (PSV) and Neurally Adjusted Ventilatory Assist (NAVA) on the aeration of the dependent and non-dependent lung regions by means of Electrical Impedance Tomography (EIT). We studied ten mechanically ventilated patients with Acute Lung Injury (ALI). Positive-End Expiratory Pressure (PEEP) and PSV levels were both 10 cm H₂O during the initial PSV step. Thereafter, we changed the inspiratory pressure to 15 and 5 cm H₂O during PSV. The electrical activity of the diaphragm (EAdi) during pressure support ten was used to define the initial NAVA gain (100 %). Thereafter, we changed NAVA gain to 150 and 50 %, respectively. After each step the assist level was switched back to PSV 10 cm H₂O or NAVA 100 % to get a new baseline. The EIT registration was performed continuously. Tidal impedance variation significantly decreased during descending PSV levels within patients, whereas not during NAVA. The dorsal-to-ventral impedance distribution, expressed according to the center of gravity index, was lower during PSV compared to NAVA. Ventilation contribution of the dependent lung region was equally in balance with the non-dependent lung region during PSV 5 cm H₂O, NAVA 50 and 100 %. Neurally Adjusted Ventilatory Assist ventilation had a beneficial effect on the ventilation of the dependent lung region and showed less over-assistance compared to PSV in patients with ALI.

  18. A 3D Visualization Method for Bladder Filling Examination Based on EIT

    Directory of Open Access Journals (Sweden)

    Wei He

    2012-01-01

    Full Text Available As the researches of electric impedance tomography (EIT applications in medical examinations deepen, we attempt to produce the visualization of 3D images of human bladder. In this paper, a planar electrode array system will be introduced as the measuring platform and a series of feasible methods are proposed to evaluate the simulated volume of bladder to avoid overfilling. The combined regularization algorithm enhances the spatial resolution and presents distinguishable sketch of disturbances from the background, which provides us with reliable data from inverse problem to carry on to the three-dimensional reconstruction. By detecting the edge elements and tracking down the lost information, we extract quantitative morphological features of the object from the noises and background. Preliminary measurements were conducted and the results showed that the proposed algorithm overcomes the defects of holes, protrusions, and debris in reconstruction. In addition, the targets' location in space and roughly volume could be calculated according to the grid of finite element of the model, and this feature was never achievable for the previous 2D imaging.

  19. Protective effects of different marigold (Calendula officinalis L.) and rosemary cream preparations against sodium-lauryl-sulfate-induced irritant contact dermatitis.

    Science.gov (United States)

    Fuchs, S M; Schliemann-Willers, S; Fischer, T W; Elsner, P

    2005-01-01

    In the present study, we evaluated the protective action of cream preparations containing seven different types of marigold and rosemary extracts in vivo in healthy volunteers with experimentally induced irritant contact dermatitis (ICD). Marigold and rosemary extracts in base cream DAC (Deutscher Arzneimittel-Codex = German Pharmaceutical Codex) were tested in a 4-day repetitive irritation test using sodium lauryl sulfate. The effect was evaluated visually and quantified by noninvasive bioengineering methods, namely chromametry and tewametry. When the test products were applied parallel to the induction period of ICD, a statistically significant protective effect of all cream preparations was observed by all methods. This effect, although not statistically significant, was superior to control by undyed marigold und faradiol ester-enriched extracts in chromametry and by dyed and undyed rosemary extracts in tewametry. The sequential treatment (postirritation) once a day for 5 days was without any effect. Thus, a protective effect of some marigold and rosemary extracts against ICD could be shown in the elicitation phase. Copyright (c) 2005 S. Karger AG, Basel.

  20. Antipruritic Effect of Cold-induced and Transient Receptor Potential-agonist-induced Counter-irritation on Histaminergic Itch in Humans

    DEFF Research Database (Denmark)

    Andersen, Hjalte H.; Melholt, Camilla; Hilborg, Sigurd D.

    2017-01-01

    A frequent empirical observation is that cold-induced counter-irritation may attenuate itch. The aim of this randomized, single-blinded, exploratory study was to evaluate the counter-irritation effects of cold-stimulation and topical application of transient receptor potential TRPA1/M8-agonists...... and trans-cinnamaldehyde had antipruritic efficacy similar to doxepin (p Cold-induced counter-irritation had an inhibitory effect on histaminergic itch, suggesting that agonists of cold transduction receptors could be of potential antipruritic value....... (measured by laser-speckle perfusion-imaging). Homotopic thermal counter-irritation was performed with 6 temperatures, ranging from 4°C to 37°C, using a 3 × 3-cm thermal stimulator. Chemical “cold-like” counter-irritation was conducted with 40% L-menthol and 10% trans-cinnamaldehyde, while 5% doxepin...

  1. Prevention of experimentally induced irritant contact dermatitis by extracts of Isatis tinctoria compared to pure tryptanthrin and its impact on UVB-induced erythema.

    Science.gov (United States)

    Heinemann, Christian; Schliemann-Willers, Sibylle; Oberthür, Christine; Hamburger, Matthias; Elsner, Peter

    2004-05-01

    Lipophilic extracts of Isatis tinctoria L. exhibit significant activity against several clinically relevant targets of inflammation. The alkaloid tryptanthrin was identified as one of the active principles in woad and characterised as a potent dual inhibitor of COX-2 and 5-LOX. Here, the anti-inflammatory efficacy of topical application of three different Isatis extracts and tryptanthrin was investigated in human volunteers. Two different models were used, namely the sodium lauryl sulphate (SLS)-induced irritant contact dermatitis (ICD) and UVB-induced erythema. Twenty healthy volunteers without any skin disease participated in the study. Cumulative irritant contact dermatitis was induced on test fields on the volunteers' backs by twice daily application of 0.5 % sodium lauryl sulphate over a period of four days. Half of the test fields were treated with the test substances during the eliciting phase, while the remaining test fields were treated over a period of 4 days after induction of dermatitis. In the second model, a UVB erythema on the volunteers' lower backs was induced using the double minimal erythema dose (MED). Twenty-four hours after irradiation the test fields were treated with the test substances over a period of 3 days. All reactions were assessed visually and by non-invasive bioengineering methods (evaporimetry and chromametry). Treatment with extracts during the ICD eliciting phase led to a significantly smaller increase of visual scores and transepidermal water loss compared to the untreated test field. For tryptanthrin this benefit was also observed, but the improvement was not statistically significant. When treatment was performed after completing the eliciting phase, accelerated resolution of the irritant reaction could not be observed. In the UVB erythema model anti-inflammatory effects of the test substances were not observed.

  2. Use of debridat in therapy of irritable colon syndrome

    International Nuclear Information System (INIS)

    Parfenov, A.I.

    1996-01-01

    It is shown that debridat is an effective means for treatment of patients with irritable colon syndrome. All patients underwent roentgenological and endoscopy examinations for determination of diagnosis and effect of their treatment

  3. An electrical impedance tomography (EIT) multi-electrode needle-probe device for local assessment of heterogeneous tissue impeditivity.

    Science.gov (United States)

    Meroni, Davide; Maglioli, Camilla Carpano; Bovio, Dario; Greco, Francesco G; Aliverti, Andrea

    2017-07-01

    Electrical Impedance Tomography (EIT) is an image reconstruction technique applied in medicine for the electrical imaging of living tissues. In literature there is the evidence that a large resistivity variation related to the differences of the human tissues exists. As a result of this interest for the electrical characterization of the biological samples, recently the attention is also focused on the identification and characterization of the human tissue, by studying the homogeneity of its structure. An 8 electrodes needle-probe device has been developed with the intent of identifying the structural inhomogeneities under the surface layers. Ex-vivo impeditivity measurements, by placing the needle-probe in 5 different patterns of fat and lean porcine tissue, were performed, and impeditivity maps were obtained by EIDORS open source software for image reconstruction in electrical impedance. The values composing the maps have been analyzed, pointing out a good tissue discrimination, and the conformity with the real images. We conclude that this device is able to perform impeditivity maps matching to reality for position and orientation. In all the five patterns presented is possible to identify and replicate correctly the heterogeneous tissue under test. This new procedure can be helpful to the medical staff to completely characterize the biological sample, in different unclear situations.

  4. A comparison of the effect of certain inorganic salts on suppression acute skin irritation by human biometric assay: A randomized, double-blind clinical trial

    Directory of Open Access Journals (Sweden)

    Sayedali Fatemi

    2016-01-01

    Full Text Available Background: Strontium, zinc, and potassium salts have been demonstrated to inhibit irritation and inflammation when applied topically. Particularly, strontium chloride (SC and potassium nitrate (KN are reported to reduce skin and tooth sensitivity. The aim of the present study was to compare the anti-irritant effects of four inorganic salts and assign the ingredient which can suppress skin irritation due to chemical or environmental exposure, more effectively. We compared the anti-inflammatory effects of SC, strontium nitrate (SN, KN, and zinc chloride (ZC. Materials and Methods: This double-blind trial was conducted on 32 healthy volunteers with sensitive skin. Irritation was induced by 24 h exposure with 1.0% sodium lauryl sulfate on arms.. Treatments were applied by an ointment of SN, SC hexahydrate, KN, and ZC and their 1%, 3%, and 5% (w/v concentrations were prepared. The dosage was twice daily for 6 days to the irritated areas. Skin reactions were evaluated instrumentally. Results: SC had a beneficial effect that was significant overall. All other treatments exert a protective effect in skin barrier function but not significantly. With the exception of ZC, all test substances improved skin hydration but the effect of SC was significant. In respect of colorimetric assessment, all treatments, excluding ZC, reduced erythema significantly compared with an untreated control 7 days after treatment start. There was no support for a dose-response effect. Conclusion: Analysis of the biometric measurements revealed that the strontium salts are best, not treating is worst, and there is little difference between the other treatments. Hence, the skin care products containing SC and SN may reduce the signs and symptoms of irritant contact dermatitis.

  5. Methodological issues in the study of intestinal microbiota in irritable bowel syndrome.

    Science.gov (United States)

    Taverniti, Valentina; Guglielmetti, Simone

    2014-07-21

    Irritable bowel syndrome (IBS) is an intestinal functional disorder with the highest prevalence in the industrialized world. The intestinal microbiota (IM) plays a role in the pathogenesis of IBS and is not merely a consequence of this disorder. Previous research efforts have not revealed unequivocal microbiological signatures of IBS, and the experimental results are contradictory. The experimental methodologies adopted to investigate the complex intestinal ecosystem drastically impact the quality and significance of the results. Therefore, to consider the methodological aspects of the research on IM in IBS, we reviewed 29 relevant original research articles identified through a PubMed search using three combinations of keywords: "irritable bowel syndrome + microflora", "irritable bowel syndrome + microbiota" and "irritable bowel syndrome + microbiome". For each study, we reviewed the quality and significance of the scientific evidence obtained with respect to the experimental method adopted. The data obtained from each study were compared with all considered publications to identify potential inconsistencies and explain contradictory results. The analytical revision of the studies referenced in the present review has contributed to the identification of microbial groups whose relative abundance significantly alters IBS, suggesting that these microbial groups could be IM signatures for this syndrome. The identification of microbial biomarkers in the IM can be advantageous for the development of new diagnostic tools and novel therapeutic strategies for the treatment of different subtypes of IBS.

  6. The effects of topical corticosteroids and a coal tar preparation on dithranol-induced irritation in patients with psoriasis

    Energy Technology Data Exchange (ETDEWEB)

    Swinkels, O.Q.J.; Kucharekova, M.; Prins, M.; Gerritsen, M.J.P.; van der Valk, P.G.M.; van de Kerkhof, P.C.M. [University of Nijmegen, Nijmegen (Netherlands). Medical Center

    2003-02-01

    Dithranol has been a mainstay in the treatment of psoriasis for more than 80 years. Although a safe approach, the irritation of the clinically uninvolved perilesional skin remains a major limitation of this treatment. Corticosteroids and coal tar solution have an anti-inflammatory potential. The aim of the present study was to investigate the clinical and cell-biological effects of two topical corticosteroids and a coal tar preparation on dithranol-irritated skin. The expression of epidermal proliferation, differentiation and inflammation markers and the clinical irritation scores indicate that the application of a high potency corticosteroid is the best approach to minimise dithranol irritation.

  7. Lurasidone for the Treatment of Irritability Associated with Autistic Disorder.

    Science.gov (United States)

    Loebel, Antony; Brams, Matthew; Goldman, Robert S; Silva, Robert; Hernandez, David; Deng, Ling; Mankoski, Raymond; Findling, Robert L

    2016-04-01

    The aim of this study was to evaluate the short-term efficacy and safety of lurasidone in treating irritability associated with autistic disorder. In this multicenter trial, outpatients age 6-17 years who met DSM-IV-TR criteria for autistic disorder, and who demonstrated irritability, agitation, and/or self-injurious behaviors were randomized to 6 weeks of double-blind treatment with lurasidone 20 mg/day (N = 50), 60 mg/day (N = 49), or placebo (N = 51). Efficacy measures included the Aberrant Behavior Checklist Irritability subscale (ABC-I, the primary endpoint) and the Clinical Global Impressions, Improvement (CGI-I) scale, and were analyzed using a likelihood-based mixed model for repeated measures. Least squares (LS) mean (standard error [SE]) improvement from baseline to Week 6 in the ABC-I was not significantly different for lurasidone 20 mg/day (-8.8 [1.5]) and lurasidone 60 mg/day (-9.4 [1.4]) versus placebo (-7.5 [1.5]; p = 0.55 and 0.36, respectively). CGI-I scores showed significantly greater LS mean [SE] improvement at Week 6 for lurasidone 20 mg/day versus placebo (2.8 [0.2] vs. 3.4 [0.2]; p = 0.035) but not for lurasidone 60 mg/day (3.1 [0.2]; p = 0.27). Discontinuation rates due to adverse events were: lurasidone 20 mg/day, 4.1%; 60 mg/day, 3.9%; and placebo, 8.2%. Adverse events with an incidence ≥10% (lurasidone combined, placebo) included vomiting (18.0, 4.1%) and somnolence (12.0, 4.1%). Modest changes were observed in weight and selected metabolic parameters. In this study, once-daily, fixed doses of 20 and 60 mg/day of lurasidone were not demonstrated to be efficacious compared to placebo for the short-term treatment of children and adolescents with moderate-to-severe irritability associated with autistic disorder.

  8. Can fecal microbiota transplantation cure irritable bowel syndrome?

    DEFF Research Database (Denmark)

    Halkjær, Sofie Ingdam; Boolsen, Anders Watt; Günther, Stig

    2017-01-01

    AIM: To verify the utility of treatment with fecal microbiota transplantation (FMT) in patients with irritable bowel syndrome (IBS). METHODS: We searched EMBASE, Cochrane Library and PubMed in March, 2017. The reviewed literature was based on two systematic searches in each of the databases. The Me...

  9. Cross-cultural validation of Irritable Bowel Syndrome Quality of Life in Korea.

    Science.gov (United States)

    Park, Jae M; Choi, Myung-Gyu; Oh, Jung Hwan; Cho, Yu Kyung; Lee, In Seok; Kim, Sang Woo; Choi, Kyu Yong; Chung, In-Sik

    2006-08-01

    Patients' responses to quality-of-life questionnaires are dependent on the cultural milieu. The aims of this study were to translate the Irritable Bowel Syndrome Quality of Life questionnaire, which was developed in the West, into Korean and to validate the translated questionnaire in patients with irritable bowel syndrome. Translation of the original questionnaire was performed according to accepted linguistic validation guidelines. Korean patients had no difficulty understanding the questions. Data from the translated questionnaire were well correlated with results from the SF-36 questionnaire and reflected the stress status of the patients as measured on the Perceived Stress Scale. Some questionnaire items seemed, on first analysis, to be problematic in this subset of patients, but these results may relate, in part, to cultural differences between Korea and the West. We conclude that the translated questionnaire is reliable and offers an accurate measure of quality of life for Korean patients with irritable bowel syndrome.

  10. Towards an Irritable Bowel Syndrome Control System Based on Artificial Neural Networks

    Science.gov (United States)

    Podolski, Ina; Rettberg, Achim

    To solve health problems with medical applications that use complex algorithms is a trend nowadays. It could also be a chance to help patients with critical problems caused from nerve irritations to overcome them and provide a better living situation. In this paper a system for monitoring and controlling the nerves from the intestine is described on a theoretical basis. The presented system could be applied to the irritable bowel syndrome. For control a neural network is used. The advantages for using a neural network for the control of irritable bowel syndrome are the adaptation and learning. These two aspects are important because the syndrome behavior varies from patient to patient and have also concerning the time a lot of variations with respect to each patient. The developed neural network is implemented and can be simulated. Therefore, it can be shown how the network monitor and control the nerves for individual input parameters.

  11. Rotational electrical impedance tomography using electrodes with limited surface coverage provides window for multimodal sensing

    Science.gov (United States)

    Lehti-Polojärvi, Mari; Koskela, Olli; Seppänen, Aku; Figueiras, Edite; Hyttinen, Jari

    2018-02-01

    Electrical impedance tomography (EIT) is an imaging method that could become a valuable tool in multimodal applications. One challenge in simultaneous multimodal imaging is that typically the EIT electrodes cover a large portion of the object surface. This paper investigates the feasibility of rotational EIT (rEIT) in applications where electrodes cover only a limited angle of the surface of the object. In the studied rEIT, the object is rotated a full 360° during a set of measurements to increase the information content of the data. We call this approach limited angle full revolution rEIT (LAFR-rEIT). We test LAFR-rEIT setups in two-dimensional geometries with computational and experimental data. We use up to 256 rotational measurement positions, which requires a new way to solve the forward and inverse problem of rEIT. For this, we provide a modification, available for EIDORS, in the supplementary material. The computational results demonstrate that LAFR-rEIT with eight electrodes produce the same image quality as conventional 16-electrode rEIT, when data from an adequate number of rotational measurement positions are used. Both computational and experimental results indicate that the novel LAFR-rEIT provides good EIT with setups with limited surface coverage and a small number of electrodes.

  12. Assessment of the eye irritation potential of chemicals: A comparison study between two test methods based on human 3D hemi-cornea models.

    Science.gov (United States)

    Tandon, R; Bartok, M; Zorn-Kruppa, M; Brandner, J M; Gabel, D; Engelke, M

    2015-12-25

    We have recently developed two hemi-cornea models (Bartok et al., Toxicol in Vitro 29, 72, 2015; Zorn-Kruppa et al. PLoS One 9, e114181, 2014), which allow the correct prediction of eye irritation potential of chemicals according to the United Nations globally harmonized system of classification and labeling of chemicals (UN GHS). Both models comprise a multilayered epithelium and a stroma with embedded keratocytes in a collagenous matrix. These two models were compared, using a set of fourteen test chemicals. Their effects after 10 and 60 minutes (min) exposure were assessed from the quantification of cell viability using the MTT reduction assay. The first approach separately quantifies the damage inflicted to the epithelium and the stroma. The second approach quantifies the depth of injury by recording cell death as a function of depth. The classification obtained by the two models was compared to the Draize rabbit eye test and an ex vivo model using rabbit cornea (Jester et al. Toxicol in Vitro. 24, 597-604, 2010). With a 60 min exposure, both of our models are able to clearly differentiate UN GHS Category 1 and UN GHS Category 2 test chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. The effectiveness of a structured educational intervention on disease-related misconception and quality of life in patients with irritable bowel syndrome.

    Science.gov (United States)

    Yu, Wen-Zhen; Ouyang, Yan-Qiong; Zhang, Qian; Li, Kong-Ling; Chen, Ji-Hong

    2014-01-01

    A significant number of patients with irritable bowel syndrome hold misconceptions about their disease and experience more impaired quality of life compared with the general population and people suffering from other chronic diseases. This study was designed to explore the effectiveness of a structured educational intervention on disease-related misconceptions and quality of life in patients with irritable bowel syndrome in Wuhan, China. A convenience sample of 23 patients with irritable bowel syndrome participated in an educational program that consisted of 4 weekly sessions in a group setting. Instruments, including an irritable bowel syndrome-related misconception scale and irritable bowel syndrome quality-of-life scale, were used for evaluation at baseline and 3 months after the sessions. Three months after the structured educational intervention, the score for irritable bowel syndrome-related misconception was significantly decreased (p quality of life was significantly improved (p educational intervention seems to be a proper method to reduce the disease-related misconceptions and improve the quality of life in patients with irritable bowel syndrome. Planning and implementing such clinical education programs will be helpful in decreasing disease-related misconceptions and promoting quality of life in patients with irritable bowel syndrome.

  14. SU-E-I-52: Validation of Multi-Frequency Electrical Impedance Tomography Using Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, K; Liu, F; Krishnan, K [BC Cancer Agency, Surrey, BC (United Kingdom)

    2014-06-01

    Purpose: Multi-frequency EIT has been reported to be a potential tool in distinguishing a tissue anomaly from background. In this study, we investigate the feasibility of acquiring functional information by comparing multi-frequency EIT images in reference to the structural information from the CT image through fusion. Methods: EIT data was acquired from a slice of winter melon using sixteen electrodes around the phantom, injecting a current of 0.4mA at 100, 66, 24.8 and 9.9 kHz. Differential EIT images were generated by considering different combinations of pair frequencies, one serving as reference data and the other as test data. The experiment was repeated after creating an anomaly in the form of an off-centered cavity of diameter 4.5 cm inside the melon. All EIT images were reconstructed using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) package in 2-D differential imaging mode using one-step Gaussian Newton minimization solver. CT image of the melon was obtained using a Phillips CT Scanner. A segmented binary mask image was generated based on the reference electrode position and the CT image to define the regions of interest. The region selected by the user was fused with the CT image through logical indexing. Results: Differential images based on the reference and test signal frequencies were reconstructed from EIT data. Result illustrated distinct structural inhomogeneity in seeded region compared to fruit flesh. The seeded region was seen as a higherimpedance region if the test frequency was lower than the base frequency in the differential EIT reconstruction. When the test frequency was higher than the base frequency, the signal experienced less electrical impedance in the seeded region during the EIT data acquisition. Conclusion: Frequency-based differential EIT imaging can be explored to provide additional functional information along with structural information from CT for identifying different tissues.

  15. SU-E-I-52: Validation of Multi-Frequency Electrical Impedance Tomography Using Computed Tomography

    International Nuclear Information System (INIS)

    Kohli, K; Liu, F; Krishnan, K

    2014-01-01

    Purpose: Multi-frequency EIT has been reported to be a potential tool in distinguishing a tissue anomaly from background. In this study, we investigate the feasibility of acquiring functional information by comparing multi-frequency EIT images in reference to the structural information from the CT image through fusion. Methods: EIT data was acquired from a slice of winter melon using sixteen electrodes around the phantom, injecting a current of 0.4mA at 100, 66, 24.8 and 9.9 kHz. Differential EIT images were generated by considering different combinations of pair frequencies, one serving as reference data and the other as test data. The experiment was repeated after creating an anomaly in the form of an off-centered cavity of diameter 4.5 cm inside the melon. All EIT images were reconstructed using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) package in 2-D differential imaging mode using one-step Gaussian Newton minimization solver. CT image of the melon was obtained using a Phillips CT Scanner. A segmented binary mask image was generated based on the reference electrode position and the CT image to define the regions of interest. The region selected by the user was fused with the CT image through logical indexing. Results: Differential images based on the reference and test signal frequencies were reconstructed from EIT data. Result illustrated distinct structural inhomogeneity in seeded region compared to fruit flesh. The seeded region was seen as a higherimpedance region if the test frequency was lower than the base frequency in the differential EIT reconstruction. When the test frequency was higher than the base frequency, the signal experienced less electrical impedance in the seeded region during the EIT data acquisition. Conclusion: Frequency-based differential EIT imaging can be explored to provide additional functional information along with structural information from CT for identifying different tissues

  16. Induced dual EIT and EIA resonances with optical trapping phenomenon in near/far fields in the N-type four-level system

    Science.gov (United States)

    Osman, Kariman I.; Joshi, Amitabh

    2017-01-01

    The optical trapping phenomenon is investigated in the probe absorptive susceptibility spectra, during the interaction of four-level N-type atomic system with three transverse Gaussian fields, in a Doppler broadened medium. The system was studied under different temperature settings of 87Rb atomic vapor as well as different non-radiative decay rate. The system exhibits a combination of dual electromagnetically induced transparency with electromagnetically induced absorption (EIA) or transparency (EIT) resonances simultaneously in near/far field. Also, the optical trapping phenomenon is considerably affected by the non-radiative decay rate.

  17. Burnout Among Chinese Adult Reconstructive Surgeons: Incidence, Risk Factors, and Relationship With Intraoperative Irritability.

    Science.gov (United States)

    Zheng, Hanlong; Shao, Hongyi; Zhou, Yixin

    2018-04-01

    Burnout is a major concern in human service occupations, mainly characterizing in emotional exhaustion and depersonalization. There is very limited research dealing with burnout in orthopedic surgeons. Exploring burnout prevalence, risk factors, and intraoperative irritability-related incidences is necessary to improve the quality of life for surgeons. The study population consisted of 202 registered adult reconstructive doctors in China. Burnout was measured using a normalized translated version of the Maslach Burnout Inventory-Human Service Survey. Demographics, professional characteristics, and intraoperative irritability-related questions were also collected by electronic questionnaires. Statistical analysis was performed using SPSS 22.0. The overall rate of burnout was 85.1%. Variables significantly associated with high emotional exhaustion scores included poor sleeping time per day (P = .008), more nights on call per week (P = .048), and absence of research (P = .014). For depersonalization, absence of marriage (P burnout, especially in emotional exhaustion. Residents were the population having the least opportunities to lose temper in operation. Burnout is highly prevalent in Chinese adult reconstructive surgeons, and it had some correlations with irritability. Further research is needed to determine more risk factors and reduce intraoperative irritability-related incidences. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Bacteria, genetics and irritable bowel syndrome.

    LENUS (Irish Health Repository)

    Craig, Orla F

    2010-06-01

    EVALUATION OF: Villani AC, Lemire M, Thabane M et al. Genetic risk factors for post-infectious irritable bowel syndrome following a waterborne outbreak of gastroenteritis. Gastroenterology 138, 1502-1513 (2010). While the pathogenesis of irritable bowel syndrome (IBS) remains to be fully defined, two clinical observations - the occurrence, de novo, of IBS following bacterial gastroenteritis and the history, commonly obtained from IBS patients, of other instances of the syndrome within their families - have instigated investigations, in IBS, of the potential roles, on the one hand, of the gut microbiota and the host response and, on the other hand, of genetic factors. The study reviewed here relates to both of these factors by studying genetic predisposition to postinfective IBS in a large population of individuals who were exposed to a multimicrobial enteric infection, which resulted in a severe outbreak of gastroenteritis and was followed by the development of IBS in over a third. In this detailed study, the investigators identified a number of genes that were linked significantly to the development of postinfectious-IBS in the Toll-like receptor 9, IL-6 and cadherin 1 regions. These genes play important roles in bacterial recognition, the inflammatory response and epithelial integrity, respectively, and provide considerable support for the hypothesis that links IBS onset to disturbances in the microbiota and the host response.

  19. Effective dose as an irritating influence during fractionated γ-irradiation

    International Nuclear Information System (INIS)

    Karpov, V.N.; Ushakov, I.B.; Davydov, B.I.

    1990-01-01

    The study of early neurological disturbances (END) in rats after fractionated γ-irradiation with doses of 37.5-225 Gy at dose rate of 30.11 Gy/min has demonstrated that the initial response of animals to pulse ionizing radiation is a function of the electric charge induced by ionizing radiation. A change in the probability of occurrence of each of the END symptoms, with the increased intervals between exposures, is merely an indirect indication of the eliminating mechanisms and is intricately connected with the irritating charge value. The proposed empiric relationships permit to correlate the probability of END symptom occurrence with the continuous quantitative parameter of fractionated irradiation, that is, with an effective dose as an analogue of the irritating effect

  20. Treatment of children with attention-deficit/hyperactivity disorder (ADHD) and irritability: results from the multimodal treatment study of children with ADHD (MTA).

    Science.gov (United States)

    Fernández de la Cruz, Lorena; Simonoff, Emily; McGough, James J; Halperin, Jeffrey M; Arnold, L Eugene; Stringaris, Argyris

    2015-01-01

    Clinically impairing irritability affects 25% to 45% of children with attention-deficit/hyperactivity disorder (ADHD); yet, we know little about what interventions are effective in treating children with ADHD and co-occurring irritability. We used data from the Multimodal Treatment Study of Children With ADHD (MTA) to address 3 aims: to establish whether irritability in children with ADHD can be distinguished from other symptoms of oppositional defiant disorder (ODD); to examine whether ADHD treatment is effective in treating irritability; and to examine how irritability influences ADHD treatment outcomes. Secondary analyses of data from the MTA included multivariate analyses, and intent-to-treat random-effects regression models were used. Irritability was separable from other ODD symptoms. For treating irritability, systematic stimulant treatment was superior to behavioral management but not to routine community care; a combination of stimulants and behavioral treatment was superior to community care and to behavioral treatment alone, but not to medication alone. Irritability did not moderate the impact of treatment on parent- and teacher-reported ADHD symptoms in any of the 4 treatment groups. Treatments targeting ADHD symptoms are helpful for improving irritability in children with ADHD. Moreover, irritability does not appear to influence the response to treatment of ADHD. Multimodal Treatment Study of Children With Attention Deficit and Hyperactivity Disorder (MTA); http://www.clinicaltrials.gov; NCT00000388. Copyright © 2015 American Academy of Child & Adolescent Psychaitry. Published by Elsevier Inc. All rights reserved.

  1. TREATMENT OF ACUTE INFLAMMATORY DISEASES ACCOMPANIED BY THROAT IRRITATION AND PAIN

    Directory of Open Access Journals (Sweden)

    M. I. Petrovskaya

    2013-01-01

    Full Text Available Pathogenetically, prescription of local action drugs containing a wide spectrum antiseptic is reasonable for the upper respiratory tract diseases accompanied by throat irritation and pain. It should be noted that such drugs are very popular among parents; however, most of these drugs may have a range of side effects, which considerably complicate their use in children. That is why the right choice of local action drugs for the acute inflammatory diseases accompanied by throat irritation and pain is a guarantee of treatment efficacy and high compliance. This article examines pharmacological qualities of an antiseptic-containing local action drug permitted to use in children over 4 years of age.

  2. The rectum: a window to irritable bowel syndrome?

    NARCIS (Netherlands)

    Coremans, G.; Azpiroz, F.; Collins, S.; Dapoigny, M.; Müller-Lissner, S. A.; Pace, F.; Smout, A.; Stockbrügger, R. W.; Whorwell, P. J.

    2002-01-01

    This report summarizes current concepts and information gathered to date about the rectum in the irritable bowel syndrome (IBS) that were presented at the 10th meeting of IBiS Club held in Leuven, Belgium. A working group of experts in the field of IBS discussed whether the rectum or the whole colon

  3. Assessment of primary eye and skin irritants by in vitro cytotoxicity and phototoxicity models: an in vitro approach of new arginine-based surfactant-induced irritation

    International Nuclear Information System (INIS)

    Benavides, T.; Mitjans, M.; Martinez, V.; Clapes, P.; Infante, M.R.; Clothier, R.H.; Vinardell, M.P.

    2004-01-01

    Extensive efforts have been made, recently, to find surfactants with lower irritation potential than those presently commercially available, for use in pharmaceutical and cosmetic preparations. Cytotoxic and phototoxic effects of a novel family of dicationic arginine-diglyceride surfactant compounds, 1,2-diacyl,3-O-(L-arginyl)-rac-glycerol with alkyl chain lengths in the range from 8 to 14 carbon atoms, were compared to three commercial surfactants. The end-points used to assess toxicity were the red blood cell lysis assay and uptake of the vital dye neutral red 24 h after dosing (NRU), respectively. Two immortalized cell lines, murine fibroblast cell line, 3T3, and one human keratinocyte cell line, HaCaT, were used as in vitro models to predict the potential phototoxicity which could result in irritation, determined by resazurin reduction to resorufin and neutral red uptake (NRU). All tested surfactants had cytotoxicity effects as demonstrated by and decrease of NR uptake, which showed a clear concentration-response relationship. Concentrations resulting in 50% inhibition of NR uptake (IC 50 ) range from 1 μmol l -1 (hexadecyl trimethyl ammonium bromide) to 565 μmol l -1 (12,12-L-arginine). Erythrocyte haemolysis also showed a clear concentration-response relationship, the 50% of haemolysis ranged from 37 μmol l -1 (10,10-L-arginine) to 151 μmol l -1 (sodium lauryl sulphate). Phototoxicity was performed with 12,12-L-acetyl-arginine, the most stable chemical structure. The validated 3T3 NRU photoxicity assay was used and revealed a phototoxic potential

  4. Refractory Depression, Fatigue, Irritable Bowel Syndrome, and Chronic Pain: A Functional Medicine Case Report.

    Science.gov (United States)

    Plotnikoff, Gregory; Barber, Melissa

    2016-01-01

    Single-disorder or single-organ-system clinical practice guidelines are often of limited usefulness in guiding effective management of patients with chronic multidimensional signs and symptoms. The presence of multiple long-standing medical problems in a given patient despite intensive medical effort suggests that addressing systemic core imbalances could complement more narrowly focused approaches. A 72-year-old man experiencing longstanding depression, fatigue, irritable bowel syndrome, and chronic pain in the context of additional refractory illnesses was assessed and treated, guided by a system-oriented approach to underlying core imbalances termed functional medicine. This patient was referred from a team of clinicians representing primary care, cardiology, gastroenterology, hematology, and psychology. Prior treatment had been unsuccessful in managing multiple chronic comorbidities. Diagnostic assessment included comprehensive stool and nutritional/metabolic laboratory testing. The blood-, urine-, or stool-based measurements of relevant markers for multiple systemic issues, including digestion/absorption, inflammation, oxidative stress, and methylation, identified previously unrecognized root causes of his constellation of symptoms. These functional measurements guided rational recommendations for dietary choices and supplementation. The patient experienced steady and significant improvement in his mental health, fatigue, chronic pain, and irritable bowel syndrome-as well as the unexpected resolution of his chronic idiopathic pancytopenia. The success in this case suggests that other patients with chronic, complex, and treatment-refractory illness may benefit from a system-oriented assessment of core imbalances guided by specialized nutritional/metabolic and digestive laboratory testing.

  5. The Prevalence of Contact Dermatitis Among Occupational and Work-related Diseases. Correlation between Atopy and Allergic or Irritative Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Codruta-Dana Pitis

    2015-12-01

    Full Text Available The prevalence of contact dermatitis (CD in Europe varies between 6.7% and 10.6% depending on the sector of activity. Professional CD (PCD has an important economic impact − 30% of the budget compensation for occupational disease. In Romania, the prevalence of PCD is underestimated, with an even distribution of cases with respect to the allergic or irritative mechanism. A retrospective clinical study was conducted; target population being the patients admitted in Occupational Medicine Clinic Cluj-Napoca between 2003 and 2011. Objectives of study were: specifying the prevalence range of allergic CD (ACD / irritative CD (ICD among occupational/work-related diseases, the distribution of allergic/irritative CD (A/ICD for different sectors of activity and establishing the correlation between atopy and A/ICD. We have applied allergy skin tests - prick (environmental allergens and patch (occupational allergens. Inclusion criteria were: -documented occupational exposure at skin allergens/irritants; -the atopy state; -diagnostic established at discharge. Patients with recurrent chronic urticaria, angioedema, hypereosinophilic syndrome have been excluded. Statistical analysis was done using SPSS software. The study indicated a similar prevalence for A/ICD, with similar distribution. Prevalence above average has been recorded in the metallurgy sector (A/ICD, in health care sector (ACD, respectively, textile industry (ICD. The correlation atopy-ACD has proved to be lower compared to previous reports. Regarding ICD, the diagnostic was confirmed frequently to non-atopic persons. We strongly recommend the compliance with a multidisciplinary protocol for the management of A/ICD, individualized for specific activity sectors or even work stations.

  6. Modulation of oral heat and cold pain by irritant chemicals.

    Science.gov (United States)

    Albin, Kelly C; Carstens, Mirela Iodi; Carstens, E

    2008-01-01

    Common food irritants elicit oral heat or cool sensations via actions at thermosensitive transient receptor potential (TRP) channels. We used a half-tongue, 2-alternative forced-choice procedure coupled with bilateral pain intensity ratings to investigate irritant effects on heat and cold pain. The method was validated in a bilateral thermal difference detection task. Capsaicin, mustard oil, and cinnamaldehyde enhanced lingual heat pain elicited by a 49 degrees C stimulus. Mustard oil and cinnamaldehyde weakly enhanced lingual cold pain (9.5 degrees C), whereas capsaicin had no effect. Menthol significantly enhanced cold pain and weakly reduced heat pain. To address if capsaicin's effect was due to summation of perceptually similar thermal and chemical sensations, one-half of the tongue was desensitized by application of capsaicin. Upon reapplication, capsaicin elicited little or no irritant sensation yet still significantly enhanced heat pain on the capsaicin-treated side, ruling out summation. In a third experiment, capsaicin significantly enhanced pain ratings to graded heat stimuli (47 degrees C to 50 degrees C) resulting in an upward shift of the stimulus-response function. Menthol may induce cold hyperalgesia via enhanced thermal gating of TRPM8 in peripheral fibers. Capsaicin, mustard oil, and cinnamaldehyde may induce heat hyperalgesia via enhanced thermal gating of TRPV1 that is coexpressed with TRPA1 in peripheral nociceptors.

  7. Simultaneous observations of electromagnetically induced transparency (EIT) and absorption (EIA) in a multi-level V-type system of 87Rb and theoretical simulation of the observed spectra using a multi-mode approach.

    Science.gov (United States)

    Das, Bankim Chandra; Bhattacharyya, Dipankar; Das, Arpita; Chakrabarti, Shrabana; De, Sankar

    2016-12-14

    We report here simultaneous experimental observation of Electromagnetically Induced Transparency (EIT) and Electromagnetically Induced Absorption (EIA) in a multi-level V-type system in D 2 transition of Rb87, i.e., F=2→F ' with a strong pump and a weak probe beam. We studied the probe spectrum by locking the probe beam to the transition F=2→F ' =2 while the pump is scanned from F=2→F ' . EIA is observed for the open transition (F=2→F ' =2) whereas EIT is observed in the closed transition (F=2→F ' =3). Sub natural line-width is observed for the EIA. To simulate the observed spectra theoretically, Liouville equation for the three-level V-type system is solved analytically with a multi-mode approach for the density matrix elements. We assumed both the pump and the probe beams can couple the excited states. A multi-mode approach for the coherence terms facilitates the study of all the frequency contributions due to the pump and the probe fields. Since the terms contain higher harmonics of the pump and the probe frequencies, we expressed them in Fourier transformed forms. To simulate the probe spectrum, we have solved inhomogeneous difference equations for the coherence terms using the Green's function technique and continued fraction theory. The experimental line-widths of the EIT and the EIA are compared with our theoretical model. Our system can be useful in optical switching applications as it can be precisely tuned to render the medium opaque and transparent simultaneously.

  8. Dithranol-loaded lipid-core nanocapsules improve the photostability and reduce the in vitro irritation potential of this drug

    Energy Technology Data Exchange (ETDEWEB)

    Savian, Ana L. [Programa de Pós-Graduação em Ciências Farmacêuticas, Universidade Federal de Santa Maria, Av. Roraima, 1000, Santa Maria, RS 97105-900 (Brazil); Rodrigues, Daiane [Curso de Farmácia, Centro de Ciências da Saúde, Universidade Federal de Santa Maria, Av. Roraima, 1000, Santa Maria, RS 97105-900 (Brazil); Weber, Julia; Ribeiro, Roseane F. [Programa de Pós-Graduação em Ciências Farmacêuticas, Universidade Federal de Santa Maria, Av. Roraima, 1000, Santa Maria, RS 97105-900 (Brazil); Motta, Mariana H. [Curso de Farmácia, Centro de Ciências da Saúde, Universidade Federal de Santa Maria, Av. Roraima, 1000, Santa Maria, RS 97105-900 (Brazil); Schaffazick, Scheila R.; Adams, Andréa I.H. [Programa de Pós-Graduação em Ciências Farmacêuticas, Universidade Federal de Santa Maria, Av. Roraima, 1000, Santa Maria, RS 97105-900 (Brazil); Andrade, Diego F. de; Beck, Ruy C.R. [Programa de Pós-Graduação em Ciências Farmacêuticas, Universidade Federal do Rio Grande do Sul, Av. Ipiranga, 2752, Porto Alegre, RS 90610-000 (Brazil); and others

    2015-01-01

    Dithranol is a very effective drug for the topical treatment of psoriasis. However, it has some adverse effects such as irritation and stain in the skin that make its application and patient adherence to treatment difficult. The aims of this work were to prepare and characterize dithranol-loaded nanocapsules as well as to evaluate the photostability and the irritation potential of these nanocarriers. Lipid-core nanocapsules containing dithranol (0.5 mg/mL) were prepared by interfacial deposition of preformed polymer. EDTA (0.05%) or ascorbic acid (0.02%) was used as antioxidants. After preparation, dithranol-loaded lipid-core nanocapsules showed satisfactory characteristics: drug content close to the theoretical concentration, encapsulation efficiency of about 100%, nanometric mean size (230–250 nm), polydispersity index below 0.25, negative zeta potential, and pH values from 4.3 to 5.6. In the photodegradation study against UVA light, we observed a higher stability of the dithranol-loaded lipid-core nanocapsules comparing to the solution containing the free drug (half-life times around 4 and 1 h for the dithranol-loaded lipid-core nanocapsules and free drug solution containing EDTA, respectively; half-life times around 17 and 7 h for the dithranol-loaded lipid-core nanocapsules and free drug solution containing ascorbic acid, respectively). Irritation test by HET-CAM method was conducted to evaluate the safety of the formulations. From the results it was found that the nanoencapsulation of the drug decreased its toxicity compared to the effects observed for the free drug. - Highlights: • Strategy to prepare lipid-core nanocapsules containing dithranol • Evaluation of the nanoencapsulation effect on the photostability and irritation • Evaluation of the in vitro release of dithranol-loaded lipid-core nanocapsules.

  9. Estimation of the in vitro eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust by using reconstituted human corneal epithelium tissue cultures

    DEFF Research Database (Denmark)

    Cao, Yi; Arenholt-Bindslev, Dorthe; Kjærgaard, Søren K

    2015-01-01

    CONTEXT: Eye irritation is a common complaint in indoor environment, but the causes have still not been identified among the multiple exposures in house environments. To identify the potential environmental factors responsible for eye irritation and study the possible mechanisms, an in vitro model...... AND CONCLUSION: LPS and dust showed in vitro eye irritating and inflammatory potential, and cytokines/chemokines like IL-1β and IL-8 may be involved in the mechanisms of eye irritation. The HCE tissue culture may be used as an in vitro model to study environmental exposure induced eye irritation and inflammation....... for eye irritation is suggested. MATERIALS AND METHODS: In this study, reconstituted human corneal epithelium (HCE) tissue cultures were used to study the eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust. HCE tissue cultures were exposed to a range of concentrations of LPS...

  10. Irritable bowel syndrome and its psychological management

    Directory of Open Access Journals (Sweden)

    Ravikesh Tripathi

    2015-01-01

    Full Text Available Irritable Bowel Syndrome (IBS is a chronic and disabling gastrointestinal problem that affects psychosocial functioning as well as the quality of life. This case study reports the utility of cognitive behavior therapy as a psychological intervention procedure in a chronic case of IBS. The use of psychological intervention was found to result in a reduction of anxiety; amelioration of the symptoms associated with IBS and improved functioning.

  11. Asian Motility Studies in Irritable Bowel Syndrome

    OpenAIRE

    Lee, Oh Young

    2010-01-01

    Altered motility remains one of the important pathophysiologic factors in patients with irritable bowel syndrome (IBS) who commonly complain of abdominal pain and stool changes such as diarrhea and constipation. The prevalence of IBS has increased among Asian populations these days. Gastrointestinal (GI) physiology may vary between Asian and Western populations because of differences in diets, socio-cultural backgrounds, and genetic factors. The characteristics and differences of GI dysmotili...

  12. The assessment of irritation using clinical methods and questionnaires

    DEFF Research Database (Denmark)

    Kjærgaard, Søren K.; Hogdson, M.

    2001-01-01

    , and hyperemia. Methods for detecting nasal mucosa irritation include measuring swelling of the nasal mucosa, peak airflows through the nose, acoustic rhinometry, and rhinostereometry, which measures thickness of the anterior nasal turbinate. Questionnaires are useful for defining a set of symptoms in an attempt...

  13. Paliperidone for irritability in adolescents and young adults with autistic disorder.

    Science.gov (United States)

    Stigler, Kimberly A; Mullett, Jennifer E; Erickson, Craig A; Posey, David J; McDougle, Christopher J

    2012-09-01

    Individuals with autistic disorder (autism) frequently exhibit significant irritability marked by severe tantrums, aggression, and self-injury. Despite advances in the treatment of this symptom domain in autism, there remains an ongoing need for more effective and better tolerated pharmacotherapies. The aim of this study is to determine the effectiveness and tolerability of paliperidone for irritability in autism. This is a prospective, 8-week open-label study of paliperidone in 25 adolescents and young adults with autism. Primary outcome measures included the Clinical Global Impressions-Improvement (CGI-I) Scale and the Irritability subscale of the Aberrant Behavior Checklist (ABC-I). Concomitant medications (except antipsychotics) were permitted if dosages were stable for ≥2 months. Twenty-one (84 %) of 25 subjects ages 12-21 years (mean 15.3 years) responded to paliperidone, based on a CGI-I Scale score of 1 or 2 (very much or much improved) and ≥25 % improvement on the ABC-I. The mean final dosage of paliperidone was 7.1 mg/day (range 3-12 mg/day). Two subjects discontinued paliperidone prior to study completion (moderate sedation, n = 1; nonresponse, n = 1). Mild-to-moderate extrapyramidal symptoms were recorded in four subjects. A mean weight gain of 2.2 ± 2.6 kg (range -3.6 to +7.9 kg) was recorded. Mean age- and sex-normed body mass index increased from 23.6 to 24.2 (p ≤ 0.001). Mean serum prolactin increased from 5.3 to 41.4 ng/mL (p ≤ 0.0001). Paliperidone treatment was associated with significant improvement in irritability and was generally well tolerated. Larger scale, placebo-controlled studies are needed to elucidate the efficacy and tolerability of paliperidone in this population.

  14. Is irritable bowel syndrome an infectious disease?

    Science.gov (United States)

    Thompson, John Richard

    2016-01-28

    Irritable bowel syndrome (IBS) is the most common of all gastroenterological diseases. While many mechanisms have been postulated to explain its etiology, no single mechanism entirely explains the heterogeneity of symptoms seen with the various phenotypes of the disease. Recent data from both basic and clinical sciences suggest that underlying infectious disease may provide a unifying hypothesis that better explains the overall symptomatology. The presence of small intestinal bowel overgrowth (SIBO) has been documented in patients with IBS and reductions in SIBO as determined by breath testing correlate with IBS symptom improvement in clinical trials. The incidence of new onset IBS symptoms following acute infectious gastroenteritis also suggests an infectious cause. Alterations in microbiota-host interactions may compromise epithelial barrier integrity, immune function, and the development and function of both central and enteric nervous systems explaining alterations in the brain-gut axis. Clinical evidence from treatment trials with both probiotics and antibiotics also support this etiology. Probiotics appear to restore the imbalance in the microflora and improve IBS-specific quality of life. Antibiotic trials with both neomycin and rifaximin show improvement in global IBS symptoms that correlates with breath test normalization in diarrhea-predominant patients. The treatment response to two weeks of rifaximin is sustained for up to ten weeks and comparable results are seen in symptom reduction with retreatment in patients who develop recurrent symptoms.

  15. Inflammation in irritable bowel syndrome: Myth or new treatment target?

    Science.gov (United States)

    Sinagra, Emanuele; Pompei, Giancarlo; Tomasello, Giovanni; Cappello, Francesco; Morreale, Gaetano Cristian; Amvrosiadis, Georgios; Rossi, Francesca; Lo Monte, Attilio Ignazio; Rizzo, Aroldo Gabriele; Raimondo, Dario

    2016-01-01

    Low-grade intestinal inflammation plays a key role in the pathophysiology of irritable bowel syndrome (IBS), and this role is likely to be multifactorial. The aim of this review was to summarize the evidence on the spectrum of mucosal inflammation in IBS, highlighting the relationship of this inflammation to the pathophysiology of IBS and its connection to clinical practice. We carried out a bibliographic search in Medline and the Cochrane Library for the period of January 1966 to December 2014, focusing on publications describing an interaction between inflammation and IBS. Several evidences demonstrate microscopic and molecular abnormalities in IBS patients. Understanding the mechanisms underlying low-grade inflammation in IBS may help to design clinical trials to test the efficacy and safety of drugs that target this pathophysiologic mechanism. PMID:26900287

  16. Assessing regional lung mechanics by combining electrical impedance tomography and forced oscillation technique.

    Science.gov (United States)

    Ngo, Chuong; Spagnesi, Sarah; Munoz, Carlos; Lehmann, Sylvia; Vollmer, Thomas; Misgeld, Berno; Leonhardt, Steffen

    2017-08-29

    There is a lack of noninvasive pulmonary function tests which can assess regional information of the lungs. Electrical impedance tomography (EIT) is a radiation-free, non-invasive real-time imaging that provides regional information of ventilation volume regarding the measurement of electrical impedance distribution. Forced oscillation technique (FOT) is a pulmonary function test which is based on the measurement of respiratory mechanical impedance over a frequency range. In this article, we introduce a new measurement approach by combining FOT and EIT, named the oscillatory electrical impedance tomography (oEIT). Our oEIT measurement system consists of a valve-based FOT device, an EIT device, pressure and flow sensors, and a computer fusing the data streams. Measurements were performed on five healthy volunteers at the frequencies 3, 4, 5, 6, 7, 8, 10, 15, and 20 Hz. The measurements suggest that the combination of FOT and EIT is a promising approach. High frequency responses are visible in the derivative of the global impedance index ΔZeit(t,fos). $\\Delta {Z_{{\\text{eit}}}}(t,{f_{{\\text{os}}}}).$ The oEIT signals consist of three main components: forced oscillation, spontaneous breathing, and heart activity. The amplitude of the oscillation component decreases with increasing frequency. The band-pass filtered oEIT signal might be a new tool in regional lung function diagnostics, since local responses to high frequency perturbation could be distinguished between different lung regions.

  17. A Measure of Proficiency or Short-Term Memory? Validation of an Elicited Imitation Test for SLA Research

    Science.gov (United States)

    Kim, Youjin; Tracy-Ventura, Nicole; Jung, Yeonjoo

    2016-01-01

    Elicited imitation requires listeners to listen and repeat sentences as accurately as possible. In second language acquisition (SLA) research it has been used for a variety of purposes. Recently, versions of the same elicited imitation test (EIT) have been created in 6 languages with the purpose of measuring second language proficiency (Ortega…

  18. Pulmonary function abnormalities and airway irritation symptoms of metal fumes exposure on automobile spot welders.

    Science.gov (United States)

    Luo, Jiin-Chyuan John; Hsu, Kuang-Hung; Shen, Wu-Shiun

    2006-06-01

    Spot or resistance welding has been considered less hazardous than other types of welding. Automobile manufacturing is a major industry in Taiwan. Spot and arc welding are common processes in this industry. The respiratory effects on automobile spot welders exposed to metal fumes are investigated. The cohort consisted of 41 male auto-body spot welders, 76 male arc welders, 71 male office workers, and 59 assemblers without welding exposure. Inductivity Coupled Plasma Mass Spectrophotometer (ICP-MS) was applied to detect metals' (zinc, copper, nickel) levels in the post-shift urine samples. Demographic data, work history, smoking status, and respiratory tract irritation symptoms were gathered by a standard self-administered questionnaire. Pulmonary function tests were also performed. There were significantly higher values for average urine metals' (zinc, copper, nickel) levels in spot welders and arc welders than in the non-welding controls. There were 4 out of 23 (17.4%) abnormal forced vital capacity (FVC) among the high-exposed spot welders, 2 out of 18 (11.1%) among the low-exposed spot welders, and 6 out of 130 (4.6%) non-welding-exposed workers. There was a significant linear trend between spot welding exposure and the prevalence of restrictive airway abnormalities (P = 0.036) after adjusting for other factors. There were 9 out of 23 (39.1%) abnormal peak expiratory flow rate (PEFR) among high-exposed spot welders, 5 out of 18 (27.8%) among the low-exposed spot welders, and 28 out of 130 (21.5%) non-welding-exposed workers. There was a borderline significant linear trend between spot welding exposure and the prevalence of obstructive lung function abnormalities (P = 0.084) after adjusting for other factors. There was also a significant dose-response relationship of airway irritation symptoms (cough, phlegm, chronic bronchitis) among the spot welders. Arc welders with high exposure status also had a significant risk of obstructive lung abnormalities (PEFR

  19. Irritable bowel syndrome--prognosis and diagnostic safety. A 5-year follow-up study

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Munck, L K; Andersen, J R

    1985-01-01

    The irritable bowel syndrome is the commonest diagnosis in gastroenterological clinics, although diagnostic criteria and investigatory programs vary. To elucidate the diagnostic safety and prognosis of the syndrome, a retrospective study was conducted. One hundred and twelve consecutive patients...... with irritable bowel syndrome as the final and only abdominal diagnosis in the period 1977-79 were followed up in 1984. Seventeen patients died during the follow-up period; two of these were considered diagnostic failures (chronic pancreatitis and pancreatic cancer). Of the remaining 95 patients, 93 were...

  20. Recommendation to test limonene hydroperoxides 0·3% and linalool hydroperoxides 1·0% in the British baseline patch test series.

    Science.gov (United States)

    Wlodek, C; Penfold, C M; Bourke, J F; Chowdhury, M M U; Cooper, S M; Ghaffar, S; Green, C; Holden, C R; Johnston, G A; Mughal, A A; Reckling, C; Sabroe, R A; Stone, N M; Thompson, D; Wilkinson, S M; Buckley, D A

    2017-12-01

    There is a significant rate of sensitization worldwide to the oxidized fragrance terpenes limonene and linalool. Patch testing to oxidized terpenes is not routinely carried out; the ideal patch test concentration is unknown. To determine the best test concentrations for limonene and linalool hydroperoxides, added to the British baseline patch test series, to optimize detection of true allergy and to minimize irritant reactions. During 2013-2014, 4563 consecutive patients in 12 U.K. centres were tested to hydroperoxides of limonene in petrolatum (pet.) 0·3%, 0·2% and 0·1%, and hydroperoxides of linalool 1·0%, 0·5% and 0·25% pet. Irritant reactions were recorded separately from doubtful reactions. Concomitant reactions to other fragrance markers and clinical relevance were documented. Limonene hydroperoxide 0·3% gave positive reactions in 241 (5·3%) patients, irritant reactions in 93 (2·0%) and doubtful reactions in 110 (2·4%). Linalool hydroperoxide 1·0% gave positive reactions in 352 (7·7%), irritant reactions in 178 (3·9%) and doubtful reactions in 132 (2·9%). A total of 119 patients with crescendo reactions to 0·3% limonene would have been missed if only tested with 0·1% and 131 patients with crescendo reactions to 1·0% linalool would have been missed if only tested with 0·25%. In almost two-thirds of patients with positive patch tests to limonene and linalool the reaction was clinically relevant. The majority of patients did not react to any fragrance marker in the baseline series. We recommend that limonene hydroperoxides be tested at 0·3% and linalool hydroperoxides at 1·0% in the British baseline patch test series. © 2017 British Association of Dermatologists.

  1. Pathology, toxicology, and latency of irritant gases known to cause bronchiolitis obliterans disease: Does diacetyl fit the pattern?

    Directory of Open Access Journals (Sweden)

    Brent D. Kerger

    2015-01-01

    Full Text Available Bronchiolitis obliterans (BO is a rare disease involving concentric bronchiolar fibrosis that develops rapidly following inhalation of certain irritant gases at sufficiently high acute doses. While there are many potential causes of bronchiolar lesions involved in a variety of chronic lung diseases, failure to clearly define the clinical features and pathological characteristics can lead to ambiguous diagnoses. Irritant gases known to cause BO follow a similar pathologic process and time course of disease onset in humans. Studies of inhaled irritant gases known to cause BO (e.g., chlorine, hydrochloric acid, ammonia, nitrogen oxides, sulfur oxides, sulfur or nitrogen mustards, and phosgene indicate that the time course between causal chemical exposures and development of clinically significant BO disease is typically limited to a few months. The mechanism of toxic action exerted by these irritant gases generally involves widespread and severe injury of the epithelial lining of the bronchioles that leads to acute respiratory symptoms which can include lung edema within days. Repeated exposures to inhaled irritant gases at concentrations insufficient to cause marked respiratory distress or edema may lead to adaptive responses that can reduce or prevent severe bronchiolar fibrotic changes. Risk of BO from irritant gases is driven substantially by toxicokinetics affecting concentrations occurring at the bronchiolar epithelium. Highly soluble irritant gases that cause BO like ammonia generally follow a threshold-dependent cytotoxic mechanism of action that at sufficiently high doses results in severe inflammation of the upper respiratory tract and the bronchiolar epithelium concurrently. This is followed by acute respiratory distress, pulmonary edema, and post inflammatory concentric fibrosis that become clinically obvious within a few months. In contrast, irritant gases with lower solubility like phosgene also follow a threshold-dependent mechanism

  2. Effectiveness of trimebutine maleate on modulating intestinal hypercontractility in a mouse model of postinfectious irritable bowel syndrome.

    Science.gov (United States)

    Long, Yanqin; Liu, Ying; Tong, Jingjing; Qian, Wei; Hou, Xiaohua

    2010-06-25

    Trimebutine maleate, which modulates the calcium and potassium channels, relieves abdominal pain in patients with irritable bowel syndrome. However, its effect on postinfectious irritable bowel syndrome is not clarified. The aim of this study was to investigate the effectiveness of trimebutine maleate on modulating colonic hypercontractility in a mouse model of postinfectious irritable bowel syndrome. Mice infected up to 8 weeks with T. spiralis underwent abdominal withdrawal reflex to colorectal distention to evaluate the visceral sensitivity at different time points. Tissues were examined for histopathology scores. Colonic longitudinal muscle strips were prepared in the organ bath under basal condition or to be stimulated by acetylcholine and potassium chloride, and consecutive concentrations of trimebutine maleate were added to the bath to record the strip responses. Significant inflammation was observed in the intestines of the mice infected 2 weeks, and it resolved in 8 weeks after infection. Visceral hyperalgesia and colonic muscle hypercontractility emerged after infection, and trimebutine maleate could effectively reduce the colonic hyperreactivity. Hypercontractility of the colonic muscle stimulated by acetylcholine and high K(+) could be inhibited by trimebutine maleate in solution with Ca(2+), but not in Ca(2+) free solution. Compared with 8-week postinfectious irritable bowel syndrome group, 2-week acute infected strips were much more sensitive to the stimulators and the drug trimebutine maleate. Trimebutine maleate was effective in reducing the colonic muscle hypercontractility of postinfectious irritable bowel syndrome mice. The findings may provide evidence for trimebutine maleate to treat postinfectious irritable bowel syndrome patients effectively. (c) 2010 Elsevier B.V. All rights reserved.

  3. Nasal chemosensory cells use bitter taste signaling to detect irritants and bacterial signals.

    Science.gov (United States)

    Tizzano, Marco; Gulbransen, Brian D; Vandenbeuch, Aurelie; Clapp, Tod R; Herman, Jake P; Sibhatu, Hiruy M; Churchill, Mair E A; Silver, Wayne L; Kinnamon, Sue C; Finger, Thomas E

    2010-02-16

    The upper respiratory tract is continually assaulted with harmful dusts and xenobiotics carried on the incoming airstream. Detection of such irritants by the trigeminal nerve evokes protective reflexes, including sneezing, apnea, and local neurogenic inflammation of the mucosa. Although free intra-epithelial nerve endings can detect certain lipophilic irritants (e.g., mints, ammonia), the epithelium also houses a population of trigeminally innervated solitary chemosensory cells (SCCs) that express T2R bitter taste receptors along with their downstream signaling components. These SCCs have been postulated to enhance the chemoresponsive capabilities of the trigeminal irritant-detection system. Here we show that transduction by the intranasal solitary chemosensory cells is necessary to evoke trigeminally mediated reflex reactions to some irritants including acyl-homoserine lactone bacterial quorum-sensing molecules, which activate the downstream signaling effectors associated with bitter taste transduction. Isolated nasal chemosensory cells respond to the classic bitter ligand denatonium as well as to the bacterial signals by increasing intracellular Ca(2+). Furthermore, these same substances evoke changes in respiration indicative of trigeminal activation. Genetic ablation of either G alpha-gustducin or TrpM5, essential elements of the T2R transduction cascade, eliminates the trigeminal response. Because acyl-homoserine lactones serve as quorum-sensing molecules for gram-negative pathogenic bacteria, detection of these substances by airway chemoreceptors offers a means by which the airway epithelium may trigger an epithelial inflammatory response before the bacteria reach population densities capable of forming destructive biofilms.

  4. Importance of neural mechanisms in colonic mucosal and muscular dysfunction in adult rats following neonatal colonic irritation

    OpenAIRE

    Chaloner, A.; Rao, A.; Al-Chaer, E.D.; Meerveld, B. Greenwood-Van

    2009-01-01

    Previous studies have shown that early life trauma induced by maternal separation or colonic irritation leads to hypersensitivity to colorectal distension in adulthood. We tested the hypothesis that repetitive colorectal distension in neonates leads to abnormalities in colonic permeability and smooth muscle function in the adult rat. In neonatal rats, repetitive colorectal distension was performed on days 8, 10, and 12. As adults, stool consistency was graded from 0 (formed stool) to 3 (liqui...

  5. EVALUATION OF PHYSICAL PROPERTIES AND IRRITATION INDEX OF LOTION CONTAINING SYZIGIUM AROMATICUM CLOVE ESSENTIAL OIL AT VARIOUS CONCENTRATION

    Directory of Open Access Journals (Sweden)

    Fadzil Latifah

    2016-04-01

    Full Text Available In this study, the lotion contained essential oil of clove Syzigium a romaticum which contained eugenol as the active ingredient. Eugenol has been scientifically proven as anti-inflammatory. Because its activity, the study about development of dosage form is needed. Aims of this study was to know the physical properties of spreadibility, adhesivity, pH, viscosity and irritation index of lotion with variation concentration of essential oil.Thisstudywasstartedwithaformulationoflotionwith variationconcentrationofessentialoil5%(FI; 10% (FII; 15% (FIII. Lotion was evaluated physical properties with parameters spreadibility, adhesivity, viscosity and pH. The evaluation of iritation index was done using guinea pig test animals. Data were analyzed statistically with One Way Anova at confidence level of 95% to detect a significant difference between the treatment groups. The results of the study showed the variation consentration did not influence pH the increasing concentration caused a decreasing spredibility P<0.05 and increasing adhesivity P<0.05. The all of concentration did not irritated the skin of guinea pigs.

  6. A protocol for a trial of homeopathic treatment for irritable bowel syndrome

    Directory of Open Access Journals (Sweden)

    Peckham Emily J

    2012-11-01

    Full Text Available Abstract Background Irritable bowel syndrome is a chronic condition with no known cure. Many sufferers seek complementary and alternative medicine including homeopathic treatment. However there is much controversy as to the effectiveness of homeopathic treatment. This three-armed study seeks to explore the effectiveness of individualised homeopathic treatment plus usual care compared to both an attention control plus usual care and usual care alone, for patients with irritable bowel syndrome. Methods/design This is a three-armed pragmatic randomised controlled trial using the cohort multiple randomised trial methodology. Patients are recruited to an irritable bowel syndrome cohort from primary and secondary care using GP databases and consultants lists respectively. From this cohort patients are randomly selected to be offered, 5 sessions of homeopathic treatment plus usual care, 5 sessions of supportive listening plus usual care or usual care alone. The primary clinical outcome is the Irritable Bowel Syndrome Symptom Severity at 26 weeks. From a power calculation, it is estimated that 33 people will be needed for the homeopathic treatment arm and 132 for the usual care arm, to detect a minimal clinical difference at 80 percent power and 5 percent significance allowing for loss to follow up. An unequal group size has been used for reasons of cost. Analysis will be by intention to treat and will compare homeopathic treatment with usual care at 26 weeks as the primary analysis, and homeopathic treatment with supportive listening as an additional analysis. Discussion This trial has received NHS approval and results are expected in 2013. Trial registration Current Controlled Trials ISRCTN90651143

  7. Bronchial asthma and COPD due to irritants in the workplace - an evidence-based approach

    Directory of Open Access Journals (Sweden)

    Baur Xaver

    2012-09-01

    Full Text Available Abstract Background Respiratory irritants represent a major cause of occupational obstructive airway diseases. We provide an overview of the evidence related to irritative agents causing occupational asthma or occupational COPD. Methods We searched MEDLINE via PubMed. Reference lists of relevant reviews were also screened. The SIGN grading system was used to rate the quality of each study. The modified RCGP three-star system was used to grade the body of evidence for each irritant agent regarding its causative role in either occupational asthma or occupational COPD. Results A total of 474 relevant papers were identified, covering 188 individual agents, professions or work-sites. The focus of most of the studies and the predominant diagnosis was occupational asthma, whereas occupational COPD arose only incidentally. The highest level assigned using the SIGN grading was 2+ (well-conducted systematic review, cohort or case–control study with a low risk of confounding or bias. According to the modified RCGP three-star grading, the strongest evidence of association with an individual agent, profession or work-site (“**” was found for 17 agents or work-sites, including benzene-1,2,4-tricarboxylicacid-1,2-anhydride, chlorine, platinum salt, isocyanates, cement dust, grain dust, animal farming, environmental tobacco smoke, welding fumes or construction work. Phthalic anhydride, glutaraldehyde, sulphur dioxide, cotton dust, cleaning agents, potrooms, farming (various, foundries were found to be moderately associated with occupational asthma or occupational COPD (“*[+]”. Conclusion This study let us assume that irritant-induced occupational asthma and especially occupational COPD are considerably underreported. Defining the evidence of the many additional occupational irritants for causing airway disorders will be the subject of continued studies with implications for diagnostics and preventive measures.

  8. Prevalence and Determinants of Mucous Membrane Irritations in a Community Near a Cement Factory in Zambia: A Cross Sectional Study

    Directory of Open Access Journals (Sweden)

    Emmy Nkhama

    2015-01-01

    Full Text Available Exposure to cement dust has been associated with deleterious health effects in humans. This study investigated whether residing near a cement factory increases the risk of irritations to the mucous membranes of the eyes and respiratory system. A cross sectional study was conducted in Freedom Compound, a community bordering a cement factory in Chilanga, Zambia and a control community, Bauleni, located 18 km from the cement plant. A modified American Thoracic Society questionnaire was administered to 225 and 198 respondents aged 15–59 years from Freedom and Bauleni, respectively, to capture symptoms of the irritations. Respondents from Freedom Compound, were more likely to experience the irritations; adjusted ORs 2.50 (95% CI: 1.65, 3.79, 4.36 (95% CI (2.96, 6.55 and 1.94 (95% CI (1.19, 3.18 for eye, nose and sinus membrane irritations respectively. Cohort panel studies to determine associations of cement emissions to mucous membrane irritations and respiratory symptoms, coupled with field characterization of the exposure are needed to assess whether the excess prevalence of symptoms of mucous membrane irritations observed in Freedom compound are due to emissions from the cement factory.

  9. Medial tibial “spackling” to lessen chronic medial tibial soft tissue irritation

    Directory of Open Access Journals (Sweden)

    J. Ryan Martin, MD

    2016-09-01

    Full Text Available We describe a unique, utilitarian reconstructive treatment option known as tibial “spackling” for chronic, localized medial joint line pain corresponding with progressive radiographic peripheral medial tibial bone loss beneath a well-fixed revision total knee arthroplasty tibial baseplate. It is believed that this localized pain is due to chronic irritation of the medial capsule and collateral ligament from the prominent medial edge of the tibial component. In the setting of failed nonoperative treatment, our experience with utilizing bone cement to reconstruct the medial tibial bone defect and create a smooth medial tibial surface has been successful in eliminating chronic medial soft tissue irritation.

  10. Cognitive-behavioral therapy for patients with irritable bowel syndrome: current insights

    Directory of Open Access Journals (Sweden)

    Kinsinger SW

    2017-07-01

    Full Text Available Sarah W Kinsinger Behavioral Medicine for Digestive Health, Division of Gastroenterology and Nutrition, Loyola University Medical Center, Maywood, IL, USA Abstract: Irritable bowel syndrome (IBS is a chronic gastrointestinal (GI condition associated with significant health care utilization and quality-of-life impairment. Latest research indicates that the brain–gut axis plays a key role in the disorder, and the presence of psychological factors and central processing deficits contribute to symptom severity and disability. Psychological therapies as a whole have demonstrated good efficacy in reducing the severity of IBS symptoms. Cognitive-behavioral therapy (CBT has been tested most rigorously in multiple randomized controlled trials and consistently demonstrates significant and durable effects on IBS symptoms and quality of life. Various protocols for treating IBS have been developed, and most recent advances in the field include exposure-based treatments to target symptom-specific anxiety as well as modified delivery methods, including internet-based treatment models. Despite the well-documented advantages of CBT for IBS, it has been poorly disseminated and few patients have access to this treatment. The primary barrier to dissemination is the limited number of therapists with adequate training in GI psychology to provide this evidence-based intervention. Future developments in the field need to focus on training opportunities to equip more therapists to competently provide CBT for this population. Further efforts to develop telemedicine platforms for delivering this intervention will also improve accessibility for patients. Keywords: irritable bowel syndrome, functional gastrointestinal disorders, cognitive-behavioral therapy

  11. Irritable and Defiant Sub-Dimensions of ODD: Their Stability and Prediction of Internalizing Symptoms and Conduct Problems from Adolescence to Young Adulthood

    Science.gov (United States)

    Homel, Jacqueline

    2016-01-01

    Emerging research has identified sub-dimensions of oppositional defiant disorder – irritability and defiance -that differentially predict internalizing and externalizing symptoms in preschoolers, children, and adolescents. Using a theoretical approach and confirmatory factor analyses to distinguish between irritability and defiance, we investigate the associations among these dimensions and internalizing (anxiety and depression) and externalizing problems (conduct problems) within and across time in a community-based sample of 662 youth (342 females) spanning ages 12 to 18 years old at baseline. On average, irritability was stable across assessment points and defiance declined. Within time, associations of irritability with internalizing were consistently stronger than associations of irritability with conduct problems. Defiance was similarly associated within time with both internalizing and conduct problems in mid-adolescence, but was more highly related to internalizing than to conduct problems by early adulthood (ages 18 to 25). Over time, increasing irritability was related to changes in both internalizing and conduct problems; whereas increases in defiance predicted increases in conduct problems more strongly than internalizing symptoms. Increases in both internalizing and conduct problems were also associated with subsequent increases in both irritability and defiance. Sex differences in these associations were not significant. PMID:25028284

  12. Contact Irritant Responses of Aedes aegypti Using Sublethal Concentration and Focal Application of Pyrethroid Chemicals

    OpenAIRE

    Manda, Hortance; Shah, Pankhil; Polsomboon, Suppaluck; Chareonviriyaphap, Theeraphap; Castro-Llanos, Fanny; Morrison, Amy; Burrus, Roxanne G.; Grieco, John P.; Achee, Nicole L.

    2013-01-01

    BACKGROUND: Previous studies have demonstrated contact irritant and spatial repellent behaviors in Aedes aegypti following exposure to sublethal concentrations of chemicals. These sublethal actions are currently being evaluated in the development of a push-pull strategy for Ae. aegypti control. This study reports on mosquito escape responses after exposure to candidate chemicals for a contact irritant focused push-pull strategy using varying concentrations and focal application. METHODS: Cont...

  13. Importance of neural mechanisms in colonic mucosal and muscular dysfunction in adult rats following neonatal colonic irritation.

    Science.gov (United States)

    Chaloner, A; Rao, A; Al-Chaer, E D; Greenwood-Van Meerveld, B

    2010-02-01

    Previous studies have shown that early life trauma induced by maternal separation or colonic irritation leads to hypersensitivity to colorectal distension in adulthood. We tested the hypothesis that repetitive colorectal distension in neonates leads to abnormalities in colonic permeability and smooth muscle function in the adult rat. In neonatal rats, repetitive colorectal distension was performed on days 8, 10, and 12. As adults, stool consistency was graded from 0 (formed stool) to 3 (liquid stool). Colonic tissue was isolated for histology and myeloperoxidase levels. The colonic mucosa was placed in modified Ussing chambers for measurements of permeability and short-circuit current responses to forskolin, electrical field stimulation, and carbachol. Segments of colonic musculature were placed in organ baths and contractile response to potassium chloride, electrical field stimulation, and carbachol were determined. In adult rats that experienced neonatal colonic irritation, no significant changes in colonic histology or myeloperoxidase activity were observed; however, stool consistency scores were increased. Mucosal permeability, measured as an increase in basal conductance, was significantly increased but no changes in short-circuit current responses were observed. In adulthood, rats that underwent colorectal distension as neonates exhibited an elevated smooth muscle contractile response to potassium chloride, but no changes in response to electrical field stimulation or carbachol. In summary, neonatal colonic irritation, shown previously to produce colonic hypersensitivity, leads to significant alterations in colonic mucosal and smooth muscle function characterized by loose stools, increased mucosal permeability, and increased smooth muscle contractility in the absence of colon inflammation in adulthood. Published by Elsevier Ltd.

  14. Radiotracer technique to predict irritation potential of soap

    International Nuclear Information System (INIS)

    Castaneda, S.S.; Garcia, T.Y.; Santos, F.L.

    1990-01-01

    The application of a radiotracer technique using tritiated water to predict the irritation potentials of some soap products is demonstrated. Collagen films are treated with 0.5% and 1.0% soap solutions and tritiated water then incubated at 50 degrees centigrade for 24 hours. After incubation, the uptake of tritiated water by the collagen films was measured by liquid scintillation counting. (Auth.). 6 refs., 2 tabs

  15. Targeted therapies for diarrhea-predominant irritable bowel syndrome

    OpenAIRE

    Olden, Kevin W

    2012-01-01

    Kevin W OldenDepartment of Medicine, St Joseph's Hospital and Medical Center, Phoenix, AZ, USAAbstract: Irritable bowel syndrome (IBS) causes gastrointestinal symptoms such as abdominal pain, bloating, and bowel pattern abnormalities, which compromise patients' daily functioning. Common therapies address one or two IBS symptoms, while others offer wider symptom control, presumably by targeting pathophysiologic mechanisms of IBS. The aim of this targeted literature review was t...

  16. Aripiprazole in the treatment of irritability in children and adolescents with autistic disorder.

    Science.gov (United States)

    Owen, Randall; Sikich, Linmarie; Marcus, Ronald N; Corey-Lisle, Patricia; Manos, George; McQuade, Robert D; Carson, William H; Findling, Robert L

    2009-12-01

    The objective of this study was to evaluate short-term efficacy and safety of aripiprazole in the treatment of irritability in children and adolescents with autistic disorder who were manifesting behaviors such as tantrums, aggression, self-injurious behavior, or a combination of these. This 8-week, double-blind, randomized, placebo-controlled, parallel-group study was conducted of children and adolescents (aged 6-17 years) with autistic disorder. Patients were randomly assigned (1:1) to flexibly dosed aripiprazole (target dosage: 5, 10, or 15 mg/day) or placebo. Efficacy outcome measures included the Aberrant Behavior Checklist irritability subscale and the Clinical Global Impression-Improvement score (CGI-I). Safety and tolerability were also assessed. Ninety-eight patients were randomly assigned to receive placebo (n = 51) or aripiprazole (n = 47). Mean improvement in Aberrant Behavior Checklist irritability subscale score was significantly greater with aripiprazole than with placebo from week 1 through week 8. Aripiprazole demonstrated significantly greater global improvements than placebo, as assessed by the mean CGI-I score from week 1 through week 8; however, clinically significant residual symptoms may still persist for some patients. Discontinuation rates as a result of adverse events (AEs) were 10.6% for aripiprazole and 5.9% for placebo. Extrapyramidal symptom-related AE rates were 14.9% for aripiprazole and 8.0% for placebo. No serious AEs were reported. Mean weight gain was 2.0 kg on aripiprazole and 0.8 kg on placebo at week 8. Aripiprazole was efficacious in children and adolescents with irritability associated with autistic disorder and was generally safe and well tolerated.

  17. New psychological therapies for irritable bowel syndrome: mindfulness, acceptance and commitment therapy (ACT

    Directory of Open Access Journals (Sweden)

    Beatriz Sebastián Sánchez

    Full Text Available The current goal of treatment in irritable bowel syndrome (IBS focuses primarily on symptom management and attempts to improve quality of life. Several treatments are at the disposal of physicians; lifestyle and dietary management, pharmacological treatments and psychological interventions are the most used and recommended. Psychological treatments have been proposed as viable alternatives or compliments to existing care models. Most forms of psychological therapies studied have been shown to be helpful in reducing symptoms and in improving the psychological component of anxiety/depression and health-related quality of life. According to current NICE/NHS guidelines, physicians should consider referral for psychological treatment in patients who do not respond to pharmacotherapy for a period of 12 months and develop a continuing symptom profile (described as refractory irritable bowel syndrome. Cognitive behavioral therapy (CBT is the best studied treatment and seems to be the most promising therapeutic approach. However, some studies have challenged the effectiveness of this therapy for irritable bowel syndrome. One study concluded that cognitive behavioral therapy is no more effective than attention placebo control condition and another study showed that the beneficial effects wane after six months of follow-up. A review of mind/body approaches to irritable bowel syndrome has therefore suggested that alternate strategies targeting mechanisms other than thought content change might be helpful, specifically mindfulness and acceptance-based approaches. In this article we review these new psychological treatment approaches in an attempt to raise awareness of alternative treatments to gastroenterologists that treat this clinical syndrome.

  18. New psychological therapies for irritable bowel syndrome: mindfulness, acceptance and commitment therapy (ACT).

    Science.gov (United States)

    Sebastián Sánchez, Beatriz; Gil Roales-Nieto, Jesús; Ferreira, Nuno Bravo; Gil Luciano, Bárbara; Sebastián Domingo, Juan José

    2017-09-01

    The current goal of treatment in irritable bowel syndrome (IBS) focuses primarily on symptom management and attempts to improve quality of life. Several treatments are at the disposal of physicians; lifestyle and dietary management, pharmacological treatments and psychological interventions are the most used and recommended. Psychological treatments have been proposed as viable alternatives or compliments to existing care models. Most forms of psychological therapies studied have been shown to be helpful in reducing symptoms and in improving the psychological component of anxiety/depression and health-related quality of life. According to current NICE/NHS guidelines, physicians should consider referral for psychological treatment in patients who do not respond to pharmacotherapy for a period of 12 months and develop a continuing symptom profile (described as refractory irritable bowel syndrome). Cognitive behavioral therapy (CBT) is the best studied treatment and seems to be the most promising therapeutic approach. However, some studies have challenged the effectiveness of this therapy for irritable bowel syndrome. One study concluded that cognitive behavioral therapy is no more effective than placebo attention control condition and another study showed that the beneficial effects wane after six months of follow-up. A review of mind/body approaches to irritable bowel syndrome has therefore suggested that alternate strategies targeting mechanisms other than thought content change might be helpful, specifically mindfulness and acceptance-based approaches. In this article we review these new psychological treatment approaches in an attempt to raise awareness of alternative treatments to gastroenterologists that treat this clinical syndrome.

  19. Development of Organogel-Derived Capsaicin Nanoemulsion with Improved Bioaccessibility and Reduced Gastric Mucosa Irritation.

    Science.gov (United States)

    Lu, Muwen; Cao, Yong; Ho, Chi-Tang; Huang, Qingrong

    2016-06-15

    Capsaicin (CAP) is the major active component in chili peppers with health-promoting benefits. However, the low bioavailability and irritating quality of CAP greatly limit its applications in functional foods. The objective of this study was to develop a food-grade nanoemulsion to increase the dissolution and bioaccessibility of CAP and to alleviate its irritating effects. To achieve this goal, CAP was first dissolved in medium-chain triacylglycerol (MCT), followed by the addition of sucrose stearate S-370 as organogelator to develop CAP-loaded organogel. The oil-in-water (O/W) emulsion was formed using organogel as the oil phase and Tween 80 as the emulsifier. After ultrasonication treatment, droplet sizes of emulsion were decreased to 168 nm with enhanced dissolution rate and bioaccessibility. In vivo study further confirmed the reduced rat gastric mucosa irritation caused by CAP. The organogel-derived nanoemulsion was proved to be an effective delivery system for CAP-based functional food products.

  20. [Irritable bowel syndrome: New pathophysiological hypotheses and practical issues].

    Science.gov (United States)

    Duboc, H; Dior, M; Coffin, B

    2016-08-01

    In 2015, besides the fact that it still fills the gastroenterologists' offices and impairs patient's quality of life, the irritable bowel syndrome has considerably evolved on several points. The pathophysiology is now organized around a consensual hypothesis called the "brain-gut axis", which gather all the influences of peripheral factors as gut microbiota or local serotonin secretion, on the central pain perception, contributing to visceral hypersensitivity and transit modifications. About the diagnosis, the key message is "avoid over-prescription" of additional tests, and reminds that a positive clinical diagnosis based on Rome III criteria is possible after the elimination of simple clinical warning signs. Finally, the food component, a neglected and historical claim of patients, finally finds a strong scientific rational, with a diet low in fermentable sugar and polyols, that gives positive and reproducible results. Copyright © 2016 Société Nationale Française de Médecine Interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  1. Povidone-iodine induced post-surgical irritant contact dermatitis localized outside of the surgical incision area. Report of 27 cases and a literature review.

    Science.gov (United States)

    Borrego, Leopoldo; Hernández, Noelia; Hernández, Zaida; Peñate, Yeray

    2016-05-01

    Povidone-iodine solution is an antiseptic that is used worldwide as surgical paint and is considered to have a low irritant potential. Post-surgical severe irritant dermatitis has been described after the misuse of this antiseptic in the surgical setting. Between January 2011 and June 2013, 27 consecutive patients with post-surgical contact dermatitis localized outside of the surgical incision area were evaluated. Thirteen patients were also available for patch testing. All patients developed dermatitis the day after the surgical procedure. Povidone-iodine solution was the only liquid in contact with the skin of our patients. Most typical lesions were distributed in a double lumbar parallel pattern, but they were also found in a random pattern or in areas where a protective pad or an occlusive medical device was glued to the skin. The patch test results with povidone-iodine were negative. Povidone-iodine-induced post-surgical dermatitis may be a severe complication after prolonged surgical procedures. As stated in the literature and based on the observation that povidone-iodine-induced contact irritant dermatitis occurred in areas of pooling or occlusion, we speculate that povidone-iodine together with occlusion were the causes of the dermatitis epidemic that occurred in our surgical setting. Povidone-iodine dermatitis is a problem that is easily preventable through the implementation of minimal routine changes to adequately dry the solution in contact with the skin. © 2015 The International Society of Dermatology.

  2. Molecular mechanisms involved in cochlear implantation trauma and the protection of hearing and auditory sensory cells by inhibition of c-Jun-N-terminal kinase signaling.

    Science.gov (United States)

    Eshraghi, Adrien A; Gupta, Chhavi; Van De Water, Thomas R; Bohorquez, Jorge E; Garnham, Carolyn; Bas, Esperanza; Talamo, Victoria Maria

    2013-03-01

    To investigate the molecular mechanisms involved in electrode insertion trauma (EIT) and to test the otoprotective effect of locally delivered AM-111. An animal model of cochlear implantation. Guinea pigs' hearing thresholds were measured by auditory brainstem response (ABR) before and after cochlear implantation in four groups: EIT; pretreated with hyaluronate gel 30 minutes before EIT (EIT+Gel); pretreated with hyaluronate gel/AM-111 30 minutes before EIT (EIT+AM-111); and unoperated contralateral ears as controls. Neurofilament, synapsin, and fluorescein isothiocyanate (FITC)-phalloidin staining for hair cell counts were performed at 90 days post-EIT. Immunostaining for 4-hydroxy-2-nonenal (HNE), activated caspase-3, CellROX, and phospho-c-Jun were performed at 24 hours post-EIT. ABR thresholds increased post-EIT in the cochleae of EIT only and EIT+Gel treated animals. There was no significant increase in hearing thresholds in cochleae from either EIT+AM-111 treated or unoperated control ears. AM-111 protection of organ of Corti sensory elements (i.e., hair cells [HCs], supporting cells [SCs], nerve fibers, and synapses) was documented at 3 months post-EIT. Immunostaining of 24-hour post-EIT specimens demonstrated increased levels of HNE in HCs and SCs; increased levels of CellROX and activation of caspase-3 was observed only in SCs, and phosphorylation of c-Jun occurred only in HCs of the EIT-only and EIT+Gel specimens. There was no immunostaining for either HNE, CellROX, caspase-3, or phospho-c-Jun in the organ of Corti specimens from AM-111 treated cochleae. Molecular mechanisms involved in programmed cell death of HCs are different than the ones involved in programmed cell death of SCs. Local delivery of AM-111 provided a significant level of protection against EIT-induced hearing losses, HC losses, and damage to neural elements. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  3. [Study on treatment of irritable bowel syndrome: based on relationship between heart and intestines].

    Science.gov (United States)

    Wang, Su-Na; Wang, Zu-Hong; Xie, Su-Juan; Han, Li-Bing; Yi, Rong

    2010-11-01

    The article puts forward the treatment of irritable bowel syndrome through regulating heart vitality since it is held that the pathological factors of the disease lay in dysfunction of heart and intestines as well as disorder of qi circulation. At the same time, the internal-external relationship between the heart the small intestine is discussed from the theory of Brain-gut Axis in modern medicine, which provides theoretical base of modern medicine for the treatment of irritable bowel syndrome through regulation of the heart functions.

  4. In vivo skin penetration of macromolecules in irritant contact dermatitis.

    Science.gov (United States)

    Abdel-Mottaleb, Mona M A; Lamprecht, Alf

    2016-12-30

    Recently, a selective preferential accumulation of polymeric nanoparticles (in the size range around 100nm) has been observed in the follicular system of dermatitis skin. The present investigation aimed at clearly investigating the effect of irritant contact dermatitis on the barrier permeability for colloidal systems below this size range, namely quantum dots and hydrophilic macromolecules. Irritant dermatitis was induced in mice and the penetrability of quantum dots (5nm) and hydrophilic dextran molecules has been tracked in both healthy and inflamed skin using confocal laser scanning microscopy. The selective accumulation of the quantum dots was clearly observed in inflamed skin while hydrophilic dextran behaved similarly in both healthy and inflamed skin. The therapeutic potential for the transdermal delivery of peptide drugs through inflamed skin has been also tested in rats. Results revealed that the transdermal permeation of insulin and calcitonin was not significantly enhanced in dermatitis compared to healthy skin. On the other side, permeation through stripped skin was significantly higher. However, the effect was limited and shorter compared to the SC injection where t min was 0.5h and 2h with a 70% and 46% reduction in blood glucose levels for the stripped skin and the SC injection respectively. Similarly, t min was 4h and 8h with area under the curve of 161±65% and 350±97% for the stripped skin and the SC injection respectively. In conclusion, the changes in skin permeability accompanied with skin inflammation did not affect its permeability to peptide drugs. Our findings also underline that experiments with the tape stripped skin model as a surrogate for inflamed skin can risk misleading conclusions due to significant difference of skin permeability between the tape stripped skin and inflamed skin. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Efficacy and Safety of Antidepressants for the Treatment of Irritable Bowel Syndrome: A Meta-Analysis

    OpenAIRE

    Xie, Chen; Tang, Yurong; Wang, Yunfeng; Yu, Ting; Wang, Yun; Jiang, Liuqin; Lin, Lin

    2015-01-01

    Aim The aim of this meta-analysis was to analyze the efficacy and safety of antidepressants for the treatment of irritable bowel syndrome. Methods We searched MEDLINE, EMBASE, Scopus and The Cochrane Library for randomized controlled trials investigating the efficacy and safety of antidepressants in the treatment of irritable bowel syndrome. Article quality was evaluated by Jadad score. RevMan 5.0 and Stata 12.0 were used for the meta-analysis. Results Twelve randomized controlled trials were...

  6. The hairless guinea-pig as a model for treatment of acute irritation in humans

    DEFF Research Database (Denmark)

    Andersen, F; Hedegaard, K; Fullerton, A

    2006-01-01

    BACKGROUND: The effect of six skin care formulations on experimentally induced acute irritation was studied in hairless guinea-pigs (HLGP) and in human volunteers (HV). The formulations were a basic cream, a carbomer cream and four modifications of the carbomer cream, containing either 10...... and colorimetry. RESULTS: The glycerol cream was the only product showing effects potentially better than no treatment in HV. CONCLUSION: The HLGP was too sensitive an animal model as a predictor for effect in humans. There was no difference in efficacy of the formulations against the two different irritants...

  7. Constructive thinking, rational intelligence and irritable bowel syndrome.

    Science.gov (United States)

    Rey, Enrique; Moreno Ortega, Marta; Garcia Alonso, Monica-Olga; Diaz-Rubio, Manuel

    2009-07-07

    To evaluate rational and experiential intelligence in irritable bowel syndrome (IBS) sufferers. We recruited 100 subjects with IBS as per Rome II criteria (50 consulters and 50 non-consulters) and 100 healthy controls, matched by age, sex and educational level. Cases and controls completed a clinical questionnaire (including symptom characteristics and medical consultation) and the following tests: rational-intelligence (Wechsler Adult Intelligence Scale, 3rd edition); experiential-intelligence (Constructive Thinking Inventory); personality (NEO personality inventory); psychopathology (MMPI-2), anxiety (state-trait anxiety inventory) and life events (social readjustment rating scale). Analysis of variance was used to compare the test results of IBS-sufferers and controls, and a logistic regression model was then constructed and adjusted for age, sex and educational level to evaluate any possible association with IBS. No differences were found between IBS cases and controls in terms of IQ (102.0 +/- 10.8 vs 102.8 +/- 12.6), but IBS sufferers scored significantly lower in global constructive thinking (43.7 +/- 9.4 vs 49.6 +/- 9.7). In the logistic regression model, global constructive thinking score was independently linked to suffering from IBS [OR 0.92 (0.87-0.97)], without significant OR for total IQ. IBS subjects do not show lower rational intelligence than controls, but lower experiential intelligence is nevertheless associated with IBS.

  8. A Study on Biocompatibility of Three Endodontic Sealers: Intensity and Duration of Tissue Irritation

    Science.gov (United States)

    Christian Gomes Moura, Camilla; Cristina Cunha, Thais; Oliveira Crema, Virgínia; Dechichi, Paula; Carlos Gabrielli Biffi, João

    2014-01-01

    Introduction: Several studies have evaluated the inflammatory reaction triggered by Epiphany (EPH), a contemporary endodontic sealer. However, they used conventional parameters, which need additional analysis to better understand the reactions induced by this sealer compared to other traditional sealers. Methods and Materials: The intensity and time span of tissue irritations for three endodontic sealers were assessed by inflammatory reactions, fibrous capsule measurement and mast cell counts. Tubes containing freshly mixed EPH, AH plus (AHP) and Endofill (ENF) were subcutaneously implanted into the backs of 28 Wistar rats. The side wall of the tube was used as the control. At 14, 21, 42 and 60 days, the connective tissue surrounding the implants (n=7) was stained for histopathological analysis. The Friedman test was applied to compare the results. The level of significance was set at 0.05. Results: At days 14 and 21, a significant difference among the groups was observed, with the ENF showing the worst tissue response (P<0.001). ENF remained the most aggressive sealer at 42 and 60 days, compared with EPH (P<0.05). No differences were found for the fibrous capsule thicknesses among the groups in each period. The number of mast cells per field did not show difference among the sealers at 21 and 60 days. Conclusions: EPH and AHP elicited similar patterns of irritation, as demonstrated by the inflammatory scores and fibrous capsule thicknesses. ENF caused the highest degree of tissue damage. The increase in mast cell counts observed during the early and late periods shows the possibility of late hypersensitivity to the test materials. PMID:24688584

  9. Evaluation of the ophthalmic and dermal irritability of the OLEOMASAJE formulation

    Directory of Open Access Journals (Sweden)

    Maritza F. Díaz

    2015-08-01

    Full Text Available Context: Ozonized vegetable oils present germicidal effects which can be used as active principle in different cosmetological compositions. The thematic about of the corporal massage advantage have been very treatment by aesthetics, dermatologic and consumers. OLEOMASAJE formulation content ozonized sunflower oil OLEOZON as active principle active which present moisturizer and conditioner effects. Aims: To determine the possible dermal and ophthalmic irritability effects of the OLEOMASAJE. Methods: The trial was conducted in rabbits and the techniques described in the standardized procedures of the work established by the Center of Biological Research and Evaluations from Pharmacy and Food Institute of Havana University were used according to Norma ISO 10993-10. The ethical principles of the Good Practices of Laboratory were fulfilled to avoid suffering to the animals during the experimentation. Male rabbits with body weight between 2.05 and 2.48 kg were used. In the skin and the ocular structures the effects were observed immediately after of the application at 1, 24, 48 and 72 hours. Draize´s scale was applied to evaluate skin and ocular structures lesions. Results: The OLEOMASAJE formulation does not irritate de skin of the assayed rabbits. However, the ocular structures irritability index was of 4.5 after of first hour to apply of product. These wounds were missing before of 24 hours to apply of product. Conclusions: The OLEOMASAJE formulation obeys the indispensable requirements for the acceptance as cosmetic product and for it is used in corporal massage.

  10. Tuning of the Hanle effect from EIT to EIA using spatially separated probe and control beams.

    Science.gov (United States)

    Bhattarai, Mangesh; Bharti, Vineet; Natarajan, Vasant

    2018-05-14

    We demonstrate a technique for continuous tuning of the Hanle effect from electromagnetically induced transparency (EIT) to electromagnetically induced absorption (EIA) by changing the polarization ellipticity of a control beam. In contrast to previous work in this field, we use spatially separated probe and control beams. The experiments are done using magnetic sublevels of the F g  = 4 → F e  = 5 closed hyperfine transition in the 852 nm D 2 line of 133 Cs. The atoms are contained in a room temperature vapor cell with anti-relaxation (paraffin) coating on the walls. The paraffin coating is necessary for the atomic coherence to be transported between the beams. The experimental results are supported by a density-matrix analysis of the system, which also explains the observed amplitude and zero-crossing of the resonances. Such continuous tuning of the sign of a resonance has important applications in quantum memory and other precision measurements.

  11. EIT image reconstruction based on a hybrid FE-EFG forward method and the complete-electrode model.

    Science.gov (United States)

    Hadinia, M; Jafari, R; Soleimani, M

    2016-06-01

    This paper presents the application of the hybrid finite element-element free Galerkin (FE-EFG) method for the forward and inverse problems of electrical impedance tomography (EIT). The proposed method is based on the complete electrode model. Finite element (FE) and element-free Galerkin (EFG) methods are accurate numerical techniques. However, the FE technique has meshing task problems and the EFG method is computationally expensive. In this paper, the hybrid FE-EFG method is applied to take both advantages of FE and EFG methods, the complete electrode model of the forward problem is solved, and an iterative regularized Gauss-Newton method is adopted to solve the inverse problem. The proposed method is applied to compute Jacobian in the inverse problem. Utilizing 2D circular homogenous models, the numerical results are validated with analytical and experimental results and the performance of the hybrid FE-EFG method compared with the FE method is illustrated. Results of image reconstruction are presented for a human chest experimental phantom.

  12. Gastric emptying and dyspeptic symptoms in the irritable bowel syndrome

    NARCIS (Netherlands)

    van Wijk, H. J.; Smout, A. J.; Akkermans, L. M.; Roelofs, J. M.; ten Thije, O. J.

    1992-01-01

    Many patients with irritable bowel syndrome (IBS) have symptoms suggestive of disturbances in gastric emptying, but so far no abnormalities in gastric emptying have been demonstrated in these patients. We studied gastric emptying of a solid meal with a 99mTc-labeled pancake in 16 healthy volunteers

  13. ['Laryngeal neuropathy' and 'irritable larynx syndrome': synonyms or distinct entities?].

    Science.gov (United States)

    Meyer, S; Ptok, M

    2012-10-01

    The term 'laryngeal neuropathy' (LN) has first been used in veterinary medicine to describe an idiopathic and typically exercise induced inspiratory noise in horses.Nowadays, the term is often used in relation with intermittent vocal cord pareses in humans. Some authors use the term 'irritable larynx syndrome' (ILS) in a similar context. This article reviews the state of knowledge regarding LN and ILS and discusses the somewhat confusing terminology.For this systematic review a selective literature research in PubMed has been carried out.35 articles were found, which report on LN in animals and 17 articles reported on humans. 4 of these articles used the term 'irritable larynx syndrome'.Laryngeal neuropathy in horses usually affects the left recurrent laryngeal nerve and results in decreased vocal cord abduction and an inspiratory roaring or whistling noise, particularly during exercise. In dogs LN has been reported to also occur bilaterally. In association with humans LN has not been defined clearly in the literature. The term ILS on the other hand has only been used in relation to humans. The term describes a hypersensitivity of the laryngeal structures towards external stimuli, which causes symptoms such as dyspnea or cough among others. Sufficient knowledge does not exist for either of the 2 diseases, ILS or LN. As of yet, the term LN should not be used in human medicine to describe according symptoms of unknown aetiology. The term 'laryngeal movement disorder' seems a lot more appropriate. The symptom oriented term irritable larynx syndrome also seems suitable to describe laryngeal hypersensitivity appropriately. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Psychological factors in the irritable bowel syndrome.

    Science.gov (United States)

    Solmaz, M; Kavuk, I; Sayar, K

    2003-12-09

    The role of psychological factors in the irritable bowel syndrome (IBS) is a matter of debate. The prevalence of psychiatric disorders is high in IBS patients. Positive response to antidepressant therapy and presence of family history of depression in IBS patients have led speculations whether this syndrome might be regarded as an affective spectrum disorder. In this study we tried to examine the possible association of IBS with affective spectrum disorders. Forty IBS patients from gastroenterology outpatient clinics of a university hospital and state hospital, 32 controls with inflammatory bowel disease and 34 healthy hospital workers were included in the study. Psychiatric interviews were done using SCID-NP (Structured Clinical Interview for DSM-Non-patients) and psychological factors were assessed by the SCL-90-R (Symptom Checklist-90-Revised), the Beck Depression Inventory, the Beck Anxiety Scale and the Hamilton Rating Scale for Depression. Family histories were obtained by FH-RDC (Family History Research Diagnostic Criteria). All groups were matched for sociodemographic variables. The prevalence of psychiatric disorders and mood disorders was higher in the IBS group than the control groups. Also IBS group rated higher on anxiety and depression scales than the other groups, where the differences were statistically significant. Presence of positive family history for mood disorders was higher in the IBS group. These results support the hypothesis that IBS might be linked to affective spectrum disorder. Psychiatric assessment and therapy might be useful in the course of irritable bowel syndrome.

  15. Sensory irritating potency of some microbial volatile organic compounds (MVOCs) and a mixture of five MVOCs.

    Science.gov (United States)

    Korpi, A; Kasanen, J P; Alarie, Y; Kosma, V M; Pasanen, A L

    1999-01-01

    The authors investigated the ability/potencies of 3 microbial volatile organic compounds and a mixture of 5 microbial volatile organic compounds to cause eye and upper respiratory tract irritation (i.e., sensory irritation), with an animal bioassay. The authors estimated potencies by determining the concentration capable of decreasing the respiratory frequency of mice by 50% (i.e., the RD50 value). The RD50 values for 1-octen-3-ol, 3-octanol, and 3-octanone were 182 mg/m3 (35 ppm), 1359 mg/m3 (256 ppm), and 17586 mg/m3 (3360 ppm), respectively. Recommended indoor air levels calculated from the individual RD50 values for 1-octen-3-ol, 3-octanol, and 3-octanone were 100, 1000, and 13000 microg/m3, respectively-values considerably higher than the reported measured indoor air levels for these compounds. The RD50 value for a mixture of 5 microbial volatile organic compounds was also determined and found to be 3.6 times lower than estimated from the fractional concentrations and the respective RD50s of the individual components. The data support the conclusion that a variety of microbial volatile organic compounds may have some synergistic effects for the sensory irritation response, which constrains the interpretation and application of recommended indoor air levels of individual microbial volatile organic compounds. The results also showed that if a particular component of a mixture was much more potent than the other components, it may dominate the sensory irritation effect. With respect to irritation symptoms reported in moldy houses, the results of this study indicate that the contribution of microbial volatile organic compounds to these symptoms seems less than previously supposed.

  16. The Role of Mast Cells in Irritable Bowel Syndrome

    OpenAIRE

    Lee, Kang Nyeong; Lee, Oh Young

    2016-01-01

    Irritable bowel syndrome (IBS) is one of the most common functional gastrointestinal disorders, but its treatment is unsatisfactory as its pathophysiology is multifactorial. The putative factors of IBS pathophysiology are visceral hypersensitivity and intestinal dysmotility, also including psychological factors, dysregulated gut-brain axis, intestinal microbiota alterations, impaired intestinal permeability, and mucosal immune alterations. Recently, mucosal immune alterations have received mu...

  17. Clinical value of radionuclide small intestine transit time measurement combined with lactulose hydrogen breath test for the diagnosis of bacterial overgrowth in irritable bowel syndrome.

    Science.gov (United States)

    Ning, Yanli; Lou, Cen; Huang, Zhongke; Chen, Dongfang; Huang, Huacheng; Chen, Liang; Zhang, Bucheng; Dai, Ning; Zhao, Jianmin; Zhen, Xia

    2016-01-01

    Small intestine bacterial overgrowth (SIBO) may be a pathogenetic factor for irritable bowel syndrome (IBS). This syndrome cannot be explained by structural abnormalities and has no specific diagnostic laboratory tests or biomarkers. We studied quantitatively and semi-quantitatively, using lactulose hydrogen breath test (LHBT), small intestinal transit time (SITT) (99m)technetium-diethylene triamine pentaacetic acid ((99m)Tc-DTPA) in order to examine the mobility of small intestine as an indication of bacterial overgrowth in patients. Eighty nine consecutive patients who met Rome criteria for IBS were retrospectively studied. According to the diagnostic criteria, all patients were divided into two groups: the SIBO group and the non-SIBO group. The tracer was a mixture of 10g lactulose, 37MBq (99m)Tc-DTPA and 100mL water. The patient drank the whole mixture during 1min and the SITT study started immediately. The SITT and the LHBT followed every 15min for up to 3h after emptying the urine bladder. Spearman's rank correlation was applied to assess the correlation of oro-cecum transit time (OCTT) between imaging and LHBT. The semi-quantitative index between the SIBO group and the non-SIBO group was analyzed with Wilcoxon's rank sum test. If there was significant group difference, the receiver operating characteristic (ROC) curve was used. Pintestinal transit time study using a lactose hydrogen breath test and (99m)Tc-DTPA is a real-time test for small intestine bacteria overgrowth in IBS patients and can be used as an indicator of the disease.

  18. Effects of irritant chemicals on Aedes aegypti resting behavior: is there a simple shift to untreated "safe sites"?

    Directory of Open Access Journals (Sweden)

    Hortance Manda

    2011-07-01

    Full Text Available BACKGROUND: Previous studies have identified the behavioral responses of Aedes aegypti to irritant and repellent chemicals that can be exploited to reduce man-vector contact. Maximum efficacy of interventions based on irritant chemical actions will, however, require full knowledge of variables that influence vector resting behavior and how untreated "safe sites" contribute to overall impact. METHODS: Using a laboratory box assay, resting patterns of two population strains of female Ae. aegypti (THAI and PERU were evaluated against two material types (cotton and polyester at various dark:light surface area coverage (SAC ratio and contrast configuration (horizontal and vertical under chemical-free and treated conditions. Chemicals evaluated were alphacypermethrin and DDT at varying concentrations. RESULTS: Under chemical-free conditions, dark material had significantly higher resting counts compared to light material at all SAC, and significantly increased when material was in horizontal configuration. Cotton elicited stronger response than polyester. Within the treatment assays, significantly higher resting counts were observed on chemical-treated dark material compared to untreated light fabric. However, compared to matched controls, significantly less resting observations were made on chemical-treated dark material overall. Most importantly, resting observations on untreated light material (or "safe sites" in the treatment assay did not significantly increase for many of the tests, even at 25% SAC. Knockdown rates were ≤5% for all assays. Significantly more observations of flying mosquitoes were made in test assays under chemical-treatment conditions as compared to controls. CONCLUSIONS/SIGNIFICANCE: When preferred Ae. aegypti resting sites are treated with chemicals, even at reduced treatment coverage area, mosquitoes do not simply move to safe sites (untreated areas following contact with the treated material. Instead, they become agitated

  19. Sodium lauryl sulfate-induced irritation in the human face: regional and age-related differences.

    Science.gov (United States)

    Marrakchi, S; Maibach, H I

    2006-01-01

    The particular sensitivity of the human face to care products prompted us to study irritation induced by sodium lauryl sulfate (SLS) in its various regions. We examined regional and age-related differences, correlating basal transepidermal water loss (TEWL) and capacitance to SLS irritation. SLS (2% aq.) was applied under occlusion for 1 h to the forehead, cheek, nose, nasolabial and perioral areas, chin, neck and forearm to two groups of subjects--one with 10 subjects with an average age of 25.2 +/- 4.7 years and another with 10 subjects with an average age of 73.7 +/- 3.9 years. TEWL was measured before and 1 h and 23 h after patch removal. Baseline stratum corneum hydration was also measured. Irritation was assessed by the changes in TEWL (deltaTEWL = TEWL after patch removal - basal TEWL) after corrections to the control. In the younger group, all areas of the face and the neck reacted to SLS, whereas the forearm did not. In the older group, the nose, perioral area and forearm did not react. In both age groups, some significant differences between the regions of the face were detected. The younger group showed higher changes in TEWL than the older group in all the areas studied, but only in the chin and nasolabial area were the differences statistically significant. Significant correlations were found between basal TEWL and deltaTEWL in 5 of the 7 areas which reacted to SLS. Baseline TEWL is one parameter that correlates with the susceptibility of the face to this irritant. 2006 S. Karger AG, Basel

  20. Acute Toxicity and Dermal and Eye Irritation of the Aqueous and Hydroalcoholic Extracts of the Seeds of “Zapote” Pouteria mammosa (L. Cronquist

    Directory of Open Access Journals (Sweden)

    Carlos M. S. Dutok

    2015-01-01

    Full Text Available The common use of Pouteria mammosa (L. Cronquist, “Mamey or Zapote,” in food and ethnobotanic medicine shows its low or absent toxicity as fruit extracts prepared from seeds. However, it is essential to conduct security trials to scientifically support their use in drug therapy. This study evaluated the aqueous and hydroalcoholic extract (25% Acute Oral Toxicity, obtained from the seeds of P. mammosa, in Sprague Dawley rats and dermal and eye irritability in New Zealand rabbits. The 404 and 405 acute dermal and eye irritation/corrosion guidelines were used, as well as the 423 Acute Oral Toxicity guideline, Acute Toxic Class Method of the Organization for Economic Cooperation and Development (OECD. The aqueous extract was located in the following category: not classified as toxic (CTA 5, while hydroalcoholic extract at 25% was classified as dangerous (CTA 4. Both extracts can be used without side reaction that irritates the skin which permitted classification as potentially not irritant. P. mammosa in the two extracts caused mild and reversible eye irritation, and it was classified as slightly irritating.