WorldWideScience

Sample records for irrigated radiofrequency catheter

  1. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  2. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    Science.gov (United States)

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  3. Safety profile of multielectrode-phased radiofrequency pulmonary vein ablation catheter and irrigated radiofrequency catheter.

    Science.gov (United States)

    Wasmer, K; Foraita, P; Leitz, P; Güner, F; Pott, C; Lange, P S; Eckardt, L; Mönnig, G

    2016-01-01

    Silent cerebral lesions with the multielectrode-phased radiofrequency (RF) pulmonary vein ablation catheter (PVAC(®)) have recently been investigated. However, comparative data on safety in relation to irrigated RF ablation are missing. One hundred and fifty consecutive patients (58 ± 12 years, 56 female) underwent first pulmonary vein isolation (PVI) for atrial fibrillation (61% paroxysmal) using PVAC(®) (PVAC). Procedure data as well as in-hospital complications were compared with 300 matched patients who underwent PVI using irrigated RF (iRF). Procedure duration (148 ± 63 vs. 208 ± 70 min; P drainage n = 0 vs. n = 6] occurred more frequently using iRF. Two patients in each group developed a TIA (1.3% vs. 0.6%). Of note, four of five thromboembolic events in the PVAC group (two TIAs and three transient ST elevations during ablation) occurred when all 10 electrodes were used for ablation. Pulmonary vein isolation using PVAC as a 'one-shot-system' has a comparable complication rate but a different risk profile. Pericardial effusion and tamponade occurred more frequently using iRF, whereas thromboembolic events were more prevalent using PVAC. Occurrence of clinically relevant thromboembolic events might be reduced by avoidance of electrode 1 and 10 interaction and uninterrupted anticoagulation, whereas contact force sensing for iRF might minimize pericardial effusion. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. Clinical impact of an open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation.

    Science.gov (United States)

    Martinek, Martin; Lemes, Christine; Sigmund, Elisabeth; Derndorfer, Michael; Aichinger, Josef; Winter, Siegmund; Nesser, Hans-Joachim; Pürerfellner, Helmut

    2012-11-01

    Electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). We assessed the impact of direct catheter force measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). Fifty consecutive patients (28 male) with paroxysmal AF who underwent their first procedure of circumferential pulmonary vein (PV) isolation (PVI) were assigned to either RFCA using (1) a standard 3.5-mm open-irrigated-tip catheter or (2) a catheter with contact force measurement capabilities. Using the endpoint of PVI with entry and exit block, acute procedural parameters were assessed. Procedural data showed a remarkable decline in ablation time (radiofrequency time needed for PVI) from 50.5 ± 15.9 to 39.0 ± 11.0 minutes (P = 0.007) with a reduction in overall procedure duration from 185 ± 46 to 154 ± 39 minutes (P = 0.022). In parallel, the total energy delivered could be significantly reduced from 70,926 ± 19,470 to 58,511 ± 14,655 Ws (P = 0.019). The number of acute PV reconnections declined from 36% to 12% (P = 0.095). The use of contact force sensing technology is able to significantly reduce ablation and procedure times in PVI. In addition, energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Procedural efficacy and safety of this new feature have to be evaluated in larger cohorts. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  5. Renal sympathetic denervation using an externally irrigated radiofrequency ablation catheter for treatment of resistant hypertension - Acute safety and short term efficacy.

    Science.gov (United States)

    Yalagudri, Sachin; Raju, Narayana; Das, Bharati; Daware, Ashwin; Maiya, Shreesha; Jothiraj, Kannan; Ravikishore, A G

    2015-01-01

    This study was conducted to assess the acute safety and short term efficacy of renal sympathetic denervation (RSDN) using solid tip radiofrequency ablation (RFA) catheter and saline irrigation through the renal guiding catheter to achieve effective denervation. RSDN using a specialized solid-tip RFA catheter has recently been demonstrated to safely reduce systemic blood pressure in patients with refractory hypertension, the limitation being inadequate power delivery in renal arteries. So, we used solid-tip RFA catheter along with saline irrigation for RSDN. Nine patients with resistant hypertension underwent CT and conventional renal angiography, followed by bilateral or unilateral RSDN using 5F RFA catheter with saline irrigation through renal guiding catheter. Repeat renal angiography was performed at the end of the procedure. In all patients, pre- and post-procedure serum creatinine was measured. Over 1-month period: 1) the systolic/diastolic blood pressure decreased by -57 ± 20/-25 ± 7.5 mm Hg; 2) all patients experienced a decrease in systolic blood pressure of at least -36 mm Hg (range 36-98 mm Hg); 3) there was no evidence of renal artery injury immediate post-procedure. There was no significant change in serum creatinine level. This data shows the acute procedural safety and short term efficacy of RSDN using modified externally irrigated solid tip RFA catheter. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  6. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  7. Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases

    Science.gov (United States)

    Mateos, José Carlos Pachón; Mateos, Enrique I Pachón; Peña, Tomas G Santillana; Lobo, Tasso Julio; Mateos, Juán Carlos Pachón; Vargas, Remy Nelson A; Pachón, Carlos Thiene C; Acosta, Juán Carlos Zerpa

    2015-01-01

    Introduction Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. Objective This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13ºC versus 1.1±0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. Conclusion Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most

  8. Determination of lesion size by ultrasound during radiofrequency catheter ablation.

    Science.gov (United States)

    Awad, S; Eick, O

    2003-01-01

    The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging.

  9. Results of Cryoenergy and Radiofrequency-Based Catheter Ablation for Treating Ventricular Arrhythmias Arising From the Papillary Muscles of the Left Ventricle, Guided by Intracardiac Echocardiography and Image Integration.

    Science.gov (United States)

    Rivera, Santiago; Ricapito, Maria de la Paz; Tomas, Leandro; Parodi, Josefina; Bardera Molina, Guillermo; Banega, Rodrigo; Bueti, Pablo; Orosco, Agustin; Reinoso, Marcelo; Caro, Milagros; Belardi, Diego; Albina, Gaston; Giniger, Alberto; Scazzuso, Fernando

    2016-04-01

    Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or radiofrequency. Twenty-one patients (40±12 years old; 47% males; median ejection fraction 59±7.3%) with drug refractory premature ventricular contractions or ventricular tachycardia underwent catheter cryoablation or radiofrequency ablation. VAs were localized using 3-dimensional mapping, multidetector computed tomography, and intracardiac echocardiography, with arrhythmia foci being mapped at either the anterolateral papillary muscle or posteromedial papillary muscles of the left ventricle. Focal ablation was performed using an 8-mm cryoablation catheter or a 4-mm open-irrigated radiofrequency catheter, via transmitral approach. Acute success rate was 100% for cryoenergy (n=12) and 78% for radiofrequency (n=9; P=0.08). Catheter stability was achieved in all patients (100%) treated with cryoenergy, and only in 2 (25%) patients treated with radiofrequency (P=0.001). Incidence of multiple VA morphologies was observed in 7 patients treated with radiofrequency (77.7%), whereas none was observed in those treated with cryoenergy (P=0.001). VA recurrence at 6 months follow-up was 0% for cryoablation and 44% for radiofrequency (P=0.03). Cryoablation was associated with higher success rates and lower recurrence rates than radiofrequency catheter ablation, better catheter stability, and lesser incidence of polymorphic arrhythmias. © 2016 American Heart Association, Inc.

  10. Radiofrequency catheter ablation of idiopathic ventricular arrhythmias originating from intramural foci in the left ventricular outflow tract: efficacy of sequential versus simultaneous unipolar catheter ablation.

    Science.gov (United States)

    Yamada, Takumi; Maddox, William R; McElderry, H Thomas; Doppalapudi, Harish; Plumb, Vance J; Kay, G Neal

    2015-04-01

    Idiopathic ventricular arrhythmias (VAs) originating from the left ventricular outflow tract (LVOT) sometimes require catheter ablation from the endocardial and epicardial sides for their elimination, suggesting the presence of intramural VA foci. This study investigated the efficacy of sequential and simultaneous unipolar radiofrequency catheter ablation from the endocardial and epicardial sides in treating intramural LVOT VAs. Fourteen consecutive LVOT VAs, which required sequential or simultaneous irrigated unipolar radiofrequency ablation from the endocardial and epicardial sides for their elimination, were studied. The first ablation was performed at the site with the earliest local ventricular activation and best pace map on the endocardial or epicardial side. When the first ablation was unsuccessful, the second ablation was delivered on the other surface. If this sequential unipolar ablation failed, simultaneous unipolar ablation from both sides was performed. The first ablation was performed on the epicardial side in 9 VAs and endocardial side in 5 VAs. The intramural LVOT VAs were successfully eliminated by the sequential (n=9) or simultaneous (n=5) unipolar catheter ablation. Simultaneous ablation was most likely to be required for the elimination of the VAs when the distance between the endocardial and epicardial ablation sites was >8 mm and the earliest local ventricular activation time relative to the QRS onset during the VAs of sequential unipolar radiofrequency ablation and sometimes required simultaneous ablation from both the endocardial and epicardial sides. © 2015 American Heart Association, Inc.

  11. [Catheter ablation in patients with refractory cardiac arrhythmias with radiofrequency techniques].

    Science.gov (United States)

    de Paola, A A; Balbão, C E; Silva Netto, O; Mendonça, A; Villacorta, H; Vattimo, A C; Souza, I A; Guiguer Júnior, N; Portugal, O P; Martinez Filho, E E

    1993-02-01

    evaluate the efficacy of radiofrequency catheter ablation in patients with refractory cardiac arrhythmias. twenty patients with refractory cardiac arrhythmias were undertaken to electrophysiologic studies for diagnosis and radiofrequency catheter ablation of their reentrant arrhythmias. Ten patients were men and 10 women with ages varying from 13 to 76 years (mean = 42.4 years). Nineteen patients had supraventricular tachyarrhythmias: One patient had atrial tachycardia and 1 atrial fibrillation with rapid ventricular rate, 5 patients had reentrant nodal tachycardia, 12 patients had reentrant atrioventricular tachycardia and 1 patient had right ventricular outflow tract tachycardia. the mean time of the procedure was 4.1 hours. The radiofrequency current energy applied was 40-50 V for 30-40 seconds. Ablation was successful in 18/20 (90%) patients; in 15/18 (83%) of successfully treated patients the same study was done for diagnosis and radiofrequency ablation. One patient had femoral arterial occlusion and was treated with no significant sequelae. During a mean follow-up of 4 months no preexcitation or reentrant tachycardia occurred. the results of our experience with radiofrequency catheter ablation of cardiac arrhythmias suggest that this technique can benefit an important number of patients with cardiac arrhythmias.

  12. Radiofrequency catheter ablation in the treatment of cardiac arrhythmias (first of two parts)

    International Nuclear Information System (INIS)

    Kou, W.H; Morady, F.

    1997-01-01

    The intravenous radiofrequency catheter inside cardiac s chambers, for inspect signals intracardiac s and to encourage, has been developed as diagnostic tool with the purpose to search arrhythmias physiology and physiopathology.Many energy sources has been used: direct energy, radiofrequency 11-15, laser 6,17, and microwave 18,19. A comparison between radiofrequency and electric energy shock has been described in cardiac arrhythmias treatment, in the present article. It has been tested the radiation biological effects and risk in Wolff Parkinson White patients as well as doctors who handling the fluoroscopy for image during the radiofrequency ablation. Has been described the following techniques: Catheter ablation radiofrequency slow way and fast way

  13. Radiofrequency catheter ablation: A study concerning electrode configuration, lesion size and potential complications

    International Nuclear Information System (INIS)

    Anfinsen, Ole-Gunnar

    1999-01-01

    The study was performed to evaluate different methods of increasing the lesion size in radiofrequency catheter ablation, which is an important issue as the clinical indications for RF ablation are extended. The safety aspects of RF ablation are also studied, both with standard catheters and with experimental ones. The studies have been performed in vitro, in an animal model and in patients. The results are presented in 5 papers with titles of: 1) 'Radiofrequency catheter ablation of procine right atrium: Increased lesion size with bipolar two-catheter technique compared to unipolar application in vitro and in vivo. 2) Bipolar radiofrequency catheter ablation creates confluent lesions at a larger interelectrode spacing than does unipolar ablation from two electrodes in porcine heart. 3) Temperature-controlled radiofrequency catheter ablation with a 10 mm tip electrode creates larger lesions without charring in the porcine heart. 4) Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor. 5) The activation of platelet function, coagulation and fibrinolysis during radiofrequency catheter ablation in heparin zed patients. The main conclusions are: 1) Large RF lesions may be created either by using larger electrodes and more power in the unipolar mode, or by changing the electrode configuration and thereby the geometry of the electrical field during RF current delivery. Both the 10 mm unipolar, the dielectrode and the bipolar mode showed feasible in porcine IVC-TV isthmus and right atrial free wall ablations, but the gain in lesion length was most pronounced in the bipolar mode. 2) Crater formation and intramural haemorrhages may complicate RF ablation using high current density in the right atrial free wall. In our study this was observed with 10 mm unipolar and bipolar two-catheter ablation. Phrenic nerve injury and lesions of the adjacent pulmonary tissue are risks related to

  14. Radiofrequency catheter ablation: A study concerning electrode configuration, lesion size and potential complications

    Energy Technology Data Exchange (ETDEWEB)

    Anfinsen, Ole-Gunnar

    1999-07-01

    The study was performed to evaluate different methods of increasing the lesion size in radiofrequency catheter ablation, which is an important issue as the clinical indications for RF ablation are extended. The safety aspects of RF ablation are also studied, both with standard catheters and with experimental ones. The studies have been performed in vitro, in an animal model and in patients. The results are presented in 5 papers with titles of: 1) 'Radiofrequency catheter ablation of procine right atrium: Increased lesion size with bipolar two-catheter technique compared to unipolar application in vitro and in vivo. 2) Bipolar radiofrequency catheter ablation creates confluent lesions at a larger interelectrode spacing than does unipolar ablation from two electrodes in porcine heart. 3) Temperature-controlled radiofrequency catheter ablation with a 10 mm tip electrode creates larger lesions without charring in the porcine heart. 4) Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor. 5) The activation of platelet function, coagulation and fibrinolysis during radiofrequency catheter ablation in heparin zed patients. The main conclusions are: 1) Large RF lesions may be created either by using larger electrodes and more power in the unipolar mode, or by changing the electrode configuration and thereby the geometry of the electrical field during RF current delivery. Both the 10 mm unipolar, the dielectrode and the bipolar mode showed feasible in porcine IVC-TV isthmus and right atrial free wall ablations, but the gain in lesion length was most pronounced in the bipolar mode. 2) Crater formation and intramural haemorrhages may complicate RF ablation using high current density in the right atrial free wall. In our study this was observed with 10 mm unipolar and bipolar two-catheter ablation. Phrenic nerve injury and lesions of the adjacent pulmonary tissue are risks

  15. Bilateral occipital lobe infarction with altitudinal field loss following radiofrequency cardiac catheter ablation

    Directory of Open Access Journals (Sweden)

    Chen Celia S

    2010-03-01

    Full Text Available Abstract Background Bilateral stroke following radiofrequency catheter ablation is an unusual complication and may result in bilateral altitudinal visual field defects. Bilateral altitudinal visual field defects usually result from prechiasmal pathology causing damage to both retinas or optic nerves and rarely from bilateral symmetric damage to the post chiasmal visual pathways. Case presentation A 48-year-old man complained of visual disturbance on wakening following radiofrequency catheter ablation. The patient had a CHADS score of 1 pre-operatively and no complications were noted intra-operatively. Examination revealed a bilateral superior altitudinal defect and MRI of the brain showed multifocal areas of infarction predominantly involving the occipital lobes which correlated to with the visual deficits. Conclusion While the risk of thromboembolism and perioperative stroke during radiofrequency catheter ablation is small, it is not insignificant.

  16. Echocardiography-guided Radiofrequency Catheter Ablation of Atrioventricular Node and VVI Pacemaker Implantation

    Directory of Open Access Journals (Sweden)

    T Guo

    2014-05-01

    Full Text Available Objective: This study is to evaluate the feasibility and safety of intracardiac radiofrequency catheter ablation (RFCA of the atrioventricular node (AVN and pacemaker implantation using transthoracic echocardiography. Methods: Eleven patients – six males and five females (mean age 66 years – with persistent or permanent atrial fibrillation/atrial flutter received RFCA of AVN and VVI pacemaker implantation (paces and senses the ventricle and is inhibited if it senses ventricular activity. Under transthoracic echocardiography, the electrode catheters were positioned intracardiac, and target ablation was performed, with the permanent pacemaking catheter in the left subclavian vein and the ablation catheter in the right femoral vein. The multi-view imaging and dynamic observation applied during the stable AV dissociation were successful. Results: Atrioventricular node ablation and permanent pacemaker implantation in 11 patients were completed successfully without X-ray exposure. The operation success rate was 100%. All patients recovered well within the follow-up period. Conclusions: Radiofrequency catheter ablation of AVN and VVI pacemaker implantation under transthoracic echocardiography guidance is a safe, easy and feasible approach. This procedure could be an important supplemental measure to catheter ablation of arrhythmia under routine X-ray fluoroscopy.

  17. Mechanisms for enlarging lesion size during irrigated tip radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Roman-Gonzalez, Javier; Johnson, Susan B

    2004-01-01

    INTRODUCTION: Irrigated tip radiofrequency ablation of cardiac arrhythmias was developed to increase the size of the radiofrequency-induced lesion, since cooling of the electrode tip allows use of higher power settings. The purpose of this study was to determine if the increased lesion size during...

  18. Prediction of radiofrequency ablation lesion formation using a novel temperature sensing technology incorporated in a force sensing catheter.

    Science.gov (United States)

    Rozen, Guy; Ptaszek, Leon; Zilberman, Israel; Cordaro, Kevin; Heist, E Kevin; Beeckler, Christopher; Altmann, Andres; Ying, Zhang; Liu, Zhenjiang; Ruskin, Jeremy N; Govari, Assaf; Mansour, Moussa

    2017-02-01

    Real-time radiofrequency (RF) ablation lesion assessment is a major unmet need in cardiac electrophysiology. The purpose of this study was to assess whether improved temperature measurement using a novel thermocoupling (TC) technology combined with information derived from impedance change, contact force (CF) sensing, and catheter orientation allows accurate real-time prediction of ablation lesion formation. RF ablation lesions were delivered in the ventricles of 15 swine using a novel externally irrigated-tip catheter containing 6 miniature TC sensors in addition to force sensing technology. Ablation duration, power, irrigation rate, impedance drop, CF, and temperature from each sensor were recorded. The catheter "orientation factor" was calculated using measurements from the different TC sensors. Information derived from all the sources was included in a mathematical model developed to predict lesion depth and validated against histologic measurements. A total of 143 ablation lesions were delivered to the left ventricle (n = 74) and right ventricle (n = 69). Mean CF applied during the ablations was 14.34 ± 3.55g, and mean impedance drop achieved during the ablations was 17.5 ± 6.41 Ω. Mean difference between predicted and measured ablation lesion depth was 0.72 ± 0.56 mm. In the majority of lesions (91.6%), the difference between estimated and measured depth was ≤1.5 mm. Accurate real-time prediction of RF lesion depth is feasible using a novel ablation catheter-based system in conjunction with a mathematical prediction model, combining elaborate temperature measurements with information derived from catheter orientation, CF sensing, impedance change, and additional ablation parameters. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  19. Optimizing radiofrequency ablation of paroxysmal and persistent atrial fibrillation by direct catheter force measurement-a case-matched comparison in 198 patients.

    Science.gov (United States)

    Sigmund, Elisabeth; Puererfellner, Helmut; Derndorfer, Michael; Kollias, Georgios; Winter, Siegmund; Aichinger, Josef; Nesser, Hans-Joachim; Martinek, Martin

    2015-02-01

    Sufficient electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). We assessed the impact of direct catheter force measurement on acute procedural parameters and outcome of RFCA for paroxysmal and persistent atrial fibrillation (AF). Ninety-nine consecutive patients (70% men) with paroxysmal (63.6%) or persistent AF underwent left atrial RFCA using a 3.5-mm open-irrigated-tip (OIT) catheter with contact force measurement capabilities (group 1). For comparison a case-matched cohort with standard OIT catheters was used (99 patients; group 2). Case matching included gender, type of AF, number or RFCA procedures, and type of procedure. Procedural data showed a significant decline in radiofrequency ablation time from 52 ± 20 to 44 ± 16 minutes (P = 0.003) with a remarkable mean reduction in overall procedure time of 34 minutes (P = 0.0001; 225.8 ± 53.1 vs 191.9 ± 53.3 minutes). In parallel, the total fluoroscopy time could be significantly reduced from 28.5 ± 11.0 to 19.9 ± 9.3 minutes (P = 0.0001) as well as fluoroscopy dose from 74.1 ± 58.0 to 56.7 ± 38.9 Gy/cm(2) (P = 0.016). Periprocedural complications were similar in both groups. The use of contact force sensing technology is able to significantly reduce ablation, procedure, and fluoroscopy times as well as dose in RFCA of AF in a mixed case-matched group of paroxysmal and persistent AF. Energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Additionally 12-month outcome data showed increased efficacy. Such time saving and equally safe technology may have a relevant impact on laboratory management and increased cost effectiveness. © 2014 Wiley Periodicals, Inc.

  20. Radiofrequency catheter ablation for electrical storm in a patient with dilated cardiomyopathy.

    Science.gov (United States)

    Kolettis, Theofilos M; Naka, Katerina K; Katsouras, Christos S

    2005-01-01

    We report a case of successful radiofrequency catheter ablation in a patient with dilated cardiomyopathy, who presented with multiple, haemodynamically poorly tolerated episodes of monomorphic ventricular tachycardia, resistant to antiarrhythmic drug treatment. The ablation procedure consisted of focal ablation of three mapped left ventricular sites, using pace and activation mapping. Additional linear ablation lesions were created across these sites. After the procedure, the patient remained free of tachycardia episodes and seven days post-ablation he underwent implantation of a cardioverter-defibrillator. During a twelve-month follow-up period, the patient has remained free of monomorphic ventricular tachycardia episodes. Radiofrequency catheter ablation is feasible in electrical storm, using conventional mapping techniques, even in haemodynamically unstable tachycardias.

  1. Comparison of renal artery, soft tissue, and nerve damage after irrigated versus nonirrigated radiofrequency ablation.

    Science.gov (United States)

    Sakakura, Kenichi; Ladich, Elena; Fuimaono, Kristine; Grunewald, Debby; O'Fallon, Patrick; Spognardi, Anna-Maria; Markham, Peter; Otsuka, Fumiyuki; Yahagi, Kazuyuki; Shen, Kai; Kolodgie, Frank D; Joner, Michael; Virmani, Renu

    2015-01-01

    The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. A total of 9 swine (18 RAs) were included, and allocated to irrigated radiofrequency (n=6 RAs, temperature setting: 50°C), conventional radiofrequency (n=6 RAs, nonirrigated, temperature setting: 65°C), and high-temperature radiofrequency (n=6 RAs, nonirrigated, temperature setting: 90°C) groups. RAs were harvested at 10 days, serially sectioned from proximal to distal including perirenal tissues and examined after paraffin embedding, and staining with hematoxylin-eosin and Movat pentachrome. RAs and periarterial tissue including nerves were semiquantitatively assessed and scored. A total of 660 histological sections from 18 RAs were histologically examined by light microscopy. Arterial medial injury was significantly less in the irrigated radiofrequency group (depth of medial injury, circumferential involvement, and thinning) than that in the conventional radiofrequency group (Pradiofrequency group (Pradiofrequency group and conventional radiofrequency group (P=0.36), there was a trend toward less nerve damage in the irrigated compared with conventional. Compared to conventional radiofrequency, circumferential medial damage in highest-temperature nonirrigated radiofrequency group was significantly greater (Pradiofrequency ablation, and there is a trend toward less nerve damage. © 2014 American Heart Association, Inc.

  2. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter.

    Science.gov (United States)

    Thiagalingam, Aravinda; D'Avila, Andre; Foley, Lori; Guerrero, J Luis; Lambert, Hendrik; Leo, Giovanni; Ruskin, Jeremy N; Reddy, Vivek Y

    2010-07-01

    Ablation electrode-tissue contact has been shown to be an important determinant of lesion size and safety during nonirrigated ablation but little data are available during irrigated ablation. We aimed to determine the importance of contact force during irrigated-tip ablation. Freshly excised hearts from 11 male pigs were perfused and superfused using fresh, heparinized, oxygenated swine blood in an ex vivo model. One-minute ablations were placed using one of 3 different power control strategies (impedance control-15 Omega target impedance drop, and 20 W or 30 W fixed power) and 3 different contact forces (2 g, 20 g, and 60 g) to give a grid of 9 ablation groups. The force sensing catheter (Tacticath, Endosense SA) was irrigated at 17 mL/min for all of the ablations. Of a total 101 ablations, no thrombus formation was noted but popping was seen in 17 lesions. The lesion depth and incidence of pops was 5.0 +/- 1.3 mm /0%, 5.0 +/- 1.6 mm /10% and 6.7 +/- 2.5 mm /45% for the 15 Omega, 20 W, and 30 W groups (P force: 9.7 +/- 9.9 Omega, 22.3 +/- 11.0 Omega, and 41.7 +/- 22.1 Omega, respectively, for the 2 g, 20 g, and 60 g groups (Pearson's r = 0.65, P force has an important impact on both ablation lesion size and the incidence of pops.

  3. Anatomical characteristics of pulmonary veins for the prediction of postoperative recurrence after radiofrequency catheter ablation of atrial fibrillation.

    Directory of Open Access Journals (Sweden)

    Wei Wei

    Full Text Available BACKGROUND: The relationship between focal pulmonary vein potential and atrial fibrillation (AF has been confirmed. Pulmonary vein (PV isolation and circumferential pulmonary vein ablation have been the most commonly used procedures of radiofrequency ablation. However, few studies have investigated the relationship between anatomical characteristics of PV and AF recurrences after radiofrequency ablation. METHODOLOGY: For 267 AF patients treated by radiofrequency catheter ablation, the anatomic structure characteristics of pulmonary veins were assessed by multi-slice spiral computed tomography while the values of left atrial diameter (LAD were measured with transesophageal ultrasonic cardiogram. After radiofrequency catheter ablation, postoperative recurrence was evaluated during a 10-month term follow-up. PRINCIPAL FINDINGS: During follow-up, postoperative recurrence occurred in 44 patients. The mean diameters of LAD, left superior PV, right superior PV, all left PV, and all superior PV were significantly larger in patients with postoperative recurrence (Recurrence vs. Non-recurrence group; 43.9 ± 6.4 mm vs. 40.7 ± 5.6 mm; 18.4 ± 2.1 mm vs. 17.1 ± 3.1 mm; 18.2 ± 2.8 mm vs. 17.2 mm ± 3.9 mm; 16.4 ± 1.5 mm vs. 15.6 ± 2.5 mm; 18.3 ± 2.1 mm vs. 17.1 ± 3.0 mm; respectively; all P < 0.05. Multivariable survival analysis showed that the type and the course of AF, LAD, and the diameters of all superior PV were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation. CONCLUSIONS: The enlargements of all superior PV and LAD, long course of diseases, and persistent AF were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.

  4. A new catheter design for combined radiofrequency ablation and optoacoustic treatment monitoring using copper-coated light-guides

    Science.gov (United States)

    Rebling, Johannes; Oyaga Landa, Francisco Javier; Deán-Ben, Xosé Luis; Razansky, Daniel

    2018-02-01

    Electrosurgery, i.e. the application of radiofrequency current for tissue ablation, is a frequently used treatment for many cardiac arrhythmias. Electrophysiological and anatomic mapping, as well as careful radiofrequency power control typically guide the radiofrequency ablation procedure. Despite its widespread application, accurate monitoring of the lesion formation with sufficient spatio-temporal resolution remains challenging with the existing imaging techniques. We present a novel integrated catheter for simultaneous radiofrequency ablation and optoacoustic monitoring of the lesion formation in real time and 3D. The design combines the delivery of both electric current and optoacoustic excitation beam in a single catheter consisting of copper-coated multimode light-guides and its manufacturing is described in detail. The electrical current causes coagulation and desiccation while the excitation light is locally absorbed, generating OA responses from the entire treated volume. The combined ablation-monitoring capabilities were verified using ex-vivo bovine tissue. The formed ablation lesions showed a homogenous coagulation while the ablation was monitored in realtime with a volumetric frame rate of 10 Hz over 150 seconds.

  5. Isolation of canine coronary sinus musculature from the atria by radiofrequency catheter ablation prevents induction of atrial fibrillation.

    Science.gov (United States)

    Morita, Hiroshi; Zipes, Douglas P; Morita, Shiho T; Wu, Jiashin

    2014-12-01

    The junction between the coronary sinus (CS) musculature and both atria contributes to initiation of atrial tachyarrhythmias. The current study investigated the effects of CS isolation from the atria by radiofrequency catheter ablation on the induction and maintenance of atrial fibrillation (AF). Using an optical mapping system, we mapped action potentials at 256 surface sites in 17 isolated and arterially perfused canine atrial tissues containing the entire musculature of the CS, right atrial septum, posterior left atrium, left inferior pulmonary vein, and vein of Marshal. Rapid pacing from each site before and after addition of acetylcholine (0.5 μmol/L) was applied to induce AF. Epicardial radiofrequency catheter ablation at CS-atrial junctions isolated the CS from the atria. Rapid pacing induced sustained AF in all tissues after acetylcholine. Microreentry within the CS drove AF in 88% of preparations. Reentries associated with the vein of Marshall (29%), CS-atrial junctions (53%), right atrium (65%), and pulmonary vein (76%) (frequently with 2-4 simultaneous circuits) were additional drivers of AF. Radiofrequency catheter ablation eliminated AF in 13 tissues before acetylcholine (Patrial tissue. The results suggest that CS can be a substrate of recurrent AF in patients after pulmonary vein isolation and that CS isolation might help prevent recurrent AF. © 2014 American Heart Association, Inc.

  6. The quest for durable lesions in catheter ablation of atrial fibrillation - technological advances in radiofrequency catheters and balloon devices.

    Science.gov (United States)

    Maurer, Tilman; Kuck, Karl-Heinz

    2017-08-01

    Atrial fibrillation is the most common cardiac arrhythmia and represents a growing clinical, social and economic challenge. Catheter ablation for symptomatic atrial fibrillation has evolved from an experimental procedure into a widespread therapy and offers a safe and effective treatment option. A prerequisite for durable PVI are transmural and contiguous circumferential lesions around the pulmonary veins. However, electrical reconnection of initially isolated pulmonary veins remains a primary concern and is a dominant factor for arrhythmia recurrence during long-term follow up. Areas covered: This article discusses the physiology of lesion formation using radiofrequency-, cryo- or laser- energy for pulmonary vein isolation and provides a detailed review of recent technological advancements in the field of radiofrequency catheters and balloon devices. Finally, future directions and upcoming developments for the interventional treatment of atrial fibrillation are discussed. Expert commentary: Durable conduction block across deployed myocardial lesions is mandatory not only for PVI but for any other cardiac ablation strategy as well. A major improvement urgently expected is the intraprocedural real-time distinction of durable lesions from interposed gaps with only transiently impaired electrical conduction. Furthermore, a simplification of ablation tools used for PVI is required to reduce the high technical complexity of the procedure.

  7. Association between success rate and citation count of studies of radiofrequency catheter ablation for atrial fibrillation: possible evidence of citation bias.

    Science.gov (United States)

    Perino, Alexander C; Hoang, Donald D; Holmes, Tyson H; Santangeli, Pasquale; Heidenreich, Paul A; Perez, Marco V; Wang, Paul J; Turakhia, Mintu P

    2014-09-01

    The preferential citation of studies with the highest success rates could exaggerate perceived effectiveness, particularly for treatments with widely varying published success rates such as radiofrequency catheter ablation for atrial fibrillation. We systematically identified observational studies and clinical trials of radiofrequency catheter ablation of atrial fibrillation between 1990 and 2012. Generalized Poisson regression was used to estimate association between study success rate and total citation count, adjusting for sample size, journal impact factor, time since publication, study design, and whether first or last author was a consensus-defined pre-eminent expert. We identified 174 articles meeting our inclusion criteria (36 289 subjects). After adjustment only for time since publication, a 10-point increase above the mean in pooled reported success rates was associated with a 17.8% increase in citation count at 5 years postpublication (95% confidence interval, 7.1-28.4%; Pcitation count; 95% confidence interval, 7.6-29.6%; Pcitation count, which may indicate citation bias. To readers of the literature, radiofrequency catheter ablation of atrial fibrillation could be perceived to be more effective than the data supports. These findings may have implications for a wide variety of novel cardiovascular therapies. © 2014 American Heart Association, Inc.

  8. Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.

    Science.gov (United States)

    Mahfoud, Felix; Tunev, Stefan; Ruwart, Jennifer; Schulz-Jander, Daniel; Cremers, Bodo; Linz, Dominik; Zeller, Thomas; Bhatt, Deepak L; Rocha-Singh, Krishna; Böhm, Michael; Melder, Robert J

    2014-12-01

    In selected patients with hypertension, renal artery (RA) stenting is used to treat significant atherosclerotic stenoses. However, blood pressure often remains uncontrolled after the procedure. Although catheter-based renal denervation (RDN) can reduce blood pressure in certain patients with resistant hypertension, there are no data on the feasibility and safety of RDN in stented RA. We report marked blood pressure reduction after RDN in a patient with resistant hypertension who underwent previous stenting. Subsequently, radiofrequency ablation was investigated within the stented segment of porcine RA, distal to the stented segment, and in nonstented RA and compared with stent only and untreated controls. There were neither observations of thrombus nor gross or histological changes in the kidneys. After radiofrequency ablation of the nonstented RA, sympathetic nerves innervating the kidney were significantly reduced, as indicated by significant decreases in sympathetic terminal axons and reduction of norepinephrine in renal tissue. Similar denervation efficacy was found when RDN was performed distal to a renal stent. In contrast, when radiofrequency ablation was performed within the stented segment of the RA, significant sympathetic nerve ablation was not seen. Histological observation showed favorable healing in all arteries. Radiofrequency ablation of previously stented RA demonstrated that RDN provides equally safe experimental procedural outcomes in a porcine model whether the radiofrequency treatment is delivered within, adjacent, or without the stent struts being present in the RA. However, efficacious RDN is only achieved when radiofrequency ablation is delivered to the nonstented RA segment distal to the stent. © 2014 American Heart Association, Inc.

  9. Accuracy of Voltage Signal Measurement During Radiofrequency Delivery Through the SMARTTOUCH Catheter.

    Science.gov (United States)

    Safavi-Naeini, Payam; Zafar-Awan, Dreema; Zhu, Hongjian; Zablah, Gerardo; Ganapathy, Anand V; Rasekh, Abdi; Saeed, Mohammad; Razavi, Joanna Esther Molina; Razavi, Mehdi

    2017-01-01

    Current methods for measuring voltage during radiofrequency (RF) ablation (RFA) necessitate turning off the ablation catheter. If voltage could be accurately read without signal attenuation during RFA, turning off the catheter would be unnecessary, allowing continuous ablation. We evaluated the accuracy of the Thermocool SMARTTOUCH catheter for measuring voltage while RF traverses the catheter. We studied 26 patients undergoing RFA for arrhythmias. A 7.5F SMARTTOUCH catheter was used for sensing voltage and performing RFA. Data were collected from the Carto-3 3-dimensional mapping system. Voltages were measured during ablation (RF-ON) and immediately before or after ablation (RF-OFF). In evaluating the accuracy of RF-ON measurements, we utilized the RF-OFF measure as the gold standard. We measured 465 voltage signals. The median values were 0.2900 and 0.3100 for RF-ON and RF-OFF, respectively. Wilcoxon signed rank testing showed no significant difference in these values (P = 0.608). The intraclass correlation coefficient (ICC) was 0.96, indicating that voltage measurements were similarly accurate during RF-OFF versus RF-ON. Five patients had baseline atrial fibrillation (AF), for whom 82 ablation points were measured; 383 additional ablation points were measured for the remaining patients. The voltages measured during RF-ON versus RF-OFF were similar in the presence of AF (P = 0.800) versus non-AF rhythm (P = 0.456) (ICC, 0.96 for both). Voltage signal measurement was similarly accurate during RF-ON versus RF-OFF independent of baseline rhythm. Physicians should consider not turning off the SMARTTOUCH ablation catheter when measuring voltage during RFA. © 2016 Wiley Periodicals, Inc.

  10. Effect of Radiofrequency Catheter Ablation on Quality of Life in Patients with Wolff-Parkinson-White Syndrome

    Directory of Open Access Journals (Sweden)

    Shokhrukh Erkaboev

    2015-09-01

    Full Text Available Wolff-Parkinson-White (WPW syndrome is one of several disorders of the conduction system of the heart that are commonly referred to as pre-excitation syndromes. As the syndrome significantly reduces the patients’ quality of life (QoL, the purpose of the current study was to compare QoL scores in patients with WPW syndrome before and after a radiofrequency catheter ablation (RFA procedure. To assess the patients’ QoL, the MOS 36-Item Short-Form Health Survey was used. Immediate and long-term outcomes of radiofrequency catheter ablation were analyzed in 60 patients diagnosed with WPW syndrome, 41(68.3% men and 19(31.7% women. As compared with the controls (28 apparently healthy persons, patients with WPW syndrome before RFA experienced significant reduction in both physical and mental health components. RFA was found effective in 93.3% of patients with WPW syndrome. At 3 months after RFA, patients showed significant improvement in both physical (13.5% and mental (17.2% health components; at 12 months, QoL parameters reached those of the controls.

  11. An efficient cardiac mapping strategy for radiofrequency catheter ablation with active learning.

    Science.gov (United States)

    Feng, Yingjing; Guo, Ziyan; Dong, Ziyang; Zhou, Xiao-Yun; Kwok, Ka-Wai; Ernst, Sabine; Lee, Su-Lin

    2017-07-01

    A major challenge in radiofrequency catheter ablation procedures is the voltage and activation mapping of the endocardium, given a limited mapping time. By learning from expert interventional electrophysiologists (operators), while also making use of an active-learning framework, guidance on performing cardiac voltage mapping can be provided to novice operators or even directly to catheter robots. A learning from demonstration (LfD) framework, based upon previous cardiac mapping procedures performed by an expert operator, in conjunction with Gaussian process (GP) model-based active learning, was developed to efficiently perform voltage mapping over right ventricles (RV). The GP model was used to output the next best mapping point, while getting updated towards the underlying voltage data pattern as more mapping points are taken. A regularized particle filter was used to keep track of the kernel hyperparameter used by GP. The travel cost of the catheter tip was incorporated to produce time-efficient mapping sequences. The proposed strategy was validated on a simulated 2D grid mapping task, with leave-one-out experiments on 25 retrospective datasets, in an RV phantom using the Stereotaxis Niobe ® remote magnetic navigation system, and on a tele-operated catheter robot. In comparison with an existing geometry-based method, regression error was reduced and was minimized at a faster rate over retrospective procedure data. A new method of catheter mapping guidance has been proposed based on LfD and active learning. The proposed method provides real-time guidance for the procedure, as well as a live evaluation of mapping sufficiency.

  12. Short and middle term outcome of radiofrequency catheter ablation for paroxysmal and sustained atrial fibrillation

    International Nuclear Information System (INIS)

    Okamoto, Mitsunori; Sueda, Takashi; Hashimoto, Masaki; Fukuda, Yukihiro; Iwamoto, Akimichi; Matsumoto, Takeshi; Shintani, Yumiko; Iwasaki, Toshitaka; Kinoshita, Hiroki

    2009-01-01

    The aim of this study was to assess short and middle term outcome of radiofrequency catheter ablation for drug-refractory paroxysmal and sustained atrial fibrillation. Subjects were 30 patients of atrial fibrillation (19 paroxysmal, 11 sustained) who underwent extensive pulmonary vein isolation from January 2007 to August 2009 in our department. Twenty three men and seven women, aged from 44 to 76 years, were enrolled. Follow-up period was one to 32 months. Drug free success was 33%, but symptoms and electrocardiogram (EGG) findings were improved in 93 % of the patients by administration of anti-arrhythmic agents. Five of the six patients with bradycardia-tachycardia syndrome was free from pacemaker implantation. Left ventricular ejection fraction was improved in two patients with dilated cardiomyopathy (DCM)-like left ventricular dysfunction. One case had cardiac tamponade and transient ST elevation due to right coronary air embolism were observed in two cases. There were no death and no cerebrovascular events during the procedures and follow-up periods. In conclusion, radiofrequency catheter ablation for paroxysmal and sustained atrial fibrillation in our department may be highly acceptable new method for improving the symptoms and clinical signs of the patients. (author)

  13. Successful Radiofrequency Catheter Ablation for Wolff-Parkinson-White Syndrome Within the Neck of a Coronary Sinus Diverticulum

    Science.gov (United States)

    Jang, Sung-Won; Kim, Dong-Bin; Kwon, Bum-Jun; Cho, Eun-Joo; Shin, Woo-Seung; Kim, Ji-Hoon; Jin, Seung-Won; Oh, Yong-Seog; Lee, Man-Young; Kim, Jae-Hyung

    2009-01-01

    Posteroseptal accessory pathways are often associated with coronary sinus diverticula. These diverticula contain myocardial coats which serve as a bypass tract. We report a 54-year-old woman who underwent radiofrequency (RF) catheter ablation for Wolff-Parkinson-White (WPW) syndrome. The surface electrocardiography (ECG) demonstrated pre-excitation, indicating a posteroseptal accessory pathway. A catheter ablation via a transaortic approach failed to ablate the accessory pathway. Coronary sinus venography revealed the presence of a diverticulum near the ostium. An electrogram in the neck of the diverticulum showed the coronary sinus myocardial extension potential, which was successfully ablated by delivery of RF energy. PMID:19949625

  14. Impact of irrigation flow rate and intrapericardial fluid on cooled-tip epicardial radiofrequency ablation.

    Science.gov (United States)

    Aryana, Arash; O'Neill, Padraig Gearoid; Pujara, Deep K; Singh, Steve K; Bowers, Mark R; Allen, Shelley L; d'Avila, André

    2016-08-01

    The optimal irrigation flow rate (IFR) during epicardial radiofrequency (RF) ablation has not been established. This study specifically examined the impact of IFR and intrapericardial fluid (IPF) accumulation during epicardial RF ablation. Altogether, 452 ex vivo RF applications (10 g for 60 seconds) delivered to the epicardial surface of bovine myocardium using 3 open-irrigated ablation catheters (ThermoCool SmartTouch, ThermoCool SmartTouch-SF, and FlexAbility) and 50 in vivo RF applications delivered (ThermoCool SmartTouch-SF) in 4 healthy adult swine in the presence or absence of IPF were examined. Ex vivo, RF was delivered at low (≤3 mL/min), reduced (5-7 mL/min), and high (≥10 mL/min) IFRs using intermediate (25-35 W) and high (35-45 W) power. In vivo, applications were delivered (at 9.3 ± 2.2 g for 60 seconds at 39 W) using reduced (5 mL/min) and high (15 mL/min) IFRs. Ex vivo, surface lesion diameter inversely correlated with IFR, whereas maximum lesion diameter and depth did not differ. While steam pops occurred more frequently at low IFR using high power (ThermoCool SmartTouch and ThermoCool SmartTouch-SF), tissue disruption was rare and did not vary with IFR. In vivo, charring/steam pop was not detected. Although there were no discernible differences in lesion size with IFR, surface lesion diameter, maximum diameter, depth, and volume were all smaller in the presence of IPF at both IFRs. Cooled-tip epicardial RF ablation created using reduced IFRs (5-7 mL/min) yields lesion sizes similar to those created using high IFRs (≥10 mL/min) without an increase in steam pop/tissue disruption, whereas the presence of IPF significantly reduces the lesion size. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. The cost-effectiveness of radiofrequency catheter ablation as first-line treatment for paroxysmal atrial fibrillation

    DEFF Research Database (Denmark)

    Aronsson, Mattias; Walfridsson, Håkan; Janzon, Magnus

    2014-01-01

    AIM: The aim of this prospective substudy was to estimate the cost-effectiveness of treating paroxysmal atrial fibrillation (AF) with radiofrequency catheter ablation (RFA) compared with antiarrhythmic drugs (AADs) as first-line treatment. METHODS AND RESULTS: A decision-analytic Markov model......, based on MANTRA-PAF (Medical Antiarrhythmic Treatment or Radiofrequency Ablation in Paroxysmal Atrial Fibrillation) study data, was developed to study long-term effects and costs of RFA compared with AADs as first-line treatment. Positive clinical effects were found in the overall population, a gain...... of an average 0.06 quality-adjusted life years (QALYs) to an incremental cost of €3033, resulting in an incremental cost-effectiveness ratio of €50 570/QALY. However, the result of the subgroup analyses showed that RFA was less costly and more effective in younger patients. This implied an incremental cost-effectiveness...

  16. Incessant ventricular tachycardia early after acute myocardial infarction: efficacy of radiofrequency catheter ablation but not of optimal coronary revascularization.

    Science.gov (United States)

    Bonanno, C; Ometto, R; Finocchi, G; Rulfo, F; La Vecchia, L; Vincenzi, M

    1999-12-01

    Incessant ventricular tachycardia is an arrhythmia refractory to conventional antiarrhythmic treatment. We describe the case of 55-year-old man who presented incessant ventricular tachycardia in the early post-acute phase of myocardial infarction. Optimal coronary revascularization was not effective, but radiofrequency catheter ablation was able to eliminate the anatomic substrate and clinical arrhythmic recurrence.

  17. Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.

    Science.gov (United States)

    Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H

    2016-05-01

    Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.

  18. Comparing the Effect of Continuous and Intermittent Irrigation Techniques on Complications of Arterial Catheter and Partial Thromboplastin Time in Patients Following Coronary Artery Bypass Grafting Surgery

    Directory of Open Access Journals (Sweden)

    Sedigheh Arta

    2017-04-01

    Full Text Available Background: Different approaches are available to irrigate the arterial catheter, such as continuous and intermittent techniques. However, there is a disagreement regarding the most appropriate method. Aim: this study aimed to compare the effect of two continuous and intermittent irrigation methods on complications of arterial catheter and partial thromboplastin time (PTT in patients with coronary artery bypass (CABG surgery. Method: This randomized clinical trial was conducted on 60 participants undergoing coronary artery bypass grafting surgery in open-heart surgery ICU at Imam Reza hospital in Mashhad, Iran, in 2016. In continuous group, the arterial catheter was continuously irrigated with heparin solution at the rate of 2cc/h, and in the intermittent group with a syringe containing 5cc heparin solution every 3 hours. In both groups, catheter was monitored and recorded every 3 hours (until 48 hours and 3 times from enrollment in terms of complications of partial thromboplastin time. Data were analyzed using SPSS version 16. Results: The findingsof independent t-test showed that the two groups are homogeneous in age (P =0.48. The result of Fisher's exact test revealed no significant difference between the two groups in terms of average incidence of complications during the first 24 hours (P=0.55 and second 24 hours (P=0.55 after catheterization. Also during the 48 hours after surgery, independent t-test results showed no statistically significant difference in partial thromboplastin time (P=0.53 between the two groups. Implications for Practice: According to the results of the research based on the lack of difference between continuous and intermittent irrigation methods up to 48 hours after catheter replacement in terms of arterial catheter complications, further long-term follow-up researches are recommended.

  19. Prognostic impact of hs-CRP and IL-6 in patients undergoing radiofrequency catheter ablation for atrial fibrillation

    DEFF Research Database (Denmark)

    Henningsen, Kristoffer Mads Aaris; Nilsson, Brian; Bruunsgaard, Helle

    2008-01-01

    Aim. The aim of this study was to assess the predictive value of inflammatory markers in patients with paroxysmal/ persistent atrial fibrillation (AF) treated with radiofrequency (RF) catheter ablation. Methods. Forty-six consecutive patients, mean age 55 years (range 31 - 81 yrs), with paroxysmal...... >10 minutes was considered failure and patients were offered a second ablation session. Interleukin-6 and high-sensitivity C-reactive protein were measured prior to ablation and at follow-up visits. Results. After a maximum of two ablations, 19 patients (41%) had SR without recurrence of AF after 12...

  20. Opportunistic use of a Foley catheter to provide a common electrocautery with a water-irrigating channel for hepatic parenchymal transection.

    Science.gov (United States)

    Yamamoto, Yuzo; Yoshioka, Masato; Watanabe, Go; Uchinami, Hiroshi

    2015-11-01

    High-tech surgical energy devices that are used during a single surgery have increased in number and the expense for such disposable units is by no means negligible. We developed a handmade water-irrigating monopolar electrocautery using a Foley catheter to perform liver parenchymal transection. A commonly used 20-24 Fr Foley catheter was cut at a length of about 8 cm. The shaft of the 5 mm ball electrode measuring 13.5 cm in length was then inlaid into the urine drainage channel. The target tissues were cauterized without making an eschar, thereby preventing the adhesion of the electrode to the tissues. A ball electrode with our handmade water irrigation sheath can be made in only a few minutes at a very low cost, using common medical supplies and yielding satisfactory effects comparable to the use of specialized high-tech devices.

  1. Catheter based radiofrequency ablation of renal nerves for the treatment of resistant hypertension

    Directory of Open Access Journals (Sweden)

    Markus P. Schlaich

    2013-03-01

    Full Text Available Introduction Resistant hypertension is a common and growing clinical problem characterized by the failure to attain target blood pressure levels despite adequate use of at least three antihypertensive agents. Objectives The aim of this article is to emphasize the role of novel approaches to treat resistant hypertension. Materials and methods After an excursus on the physiological role of renal nerves on kidney function, volume homeostasis and blood pressure control, this article describes the radiofrequency ablation technology to obtain kidneys denervation. Results Activation of the sympathetic nervous system plays a prominent role as a major regulator of circulatory and metabolic control. The kidneys have a particularly dense afferent sensory and efferent sympathetic innervation and are thereby strategically positioned to be origin as well as target of sympathetic activation. In this context, recent evidence suggests that a novel catheter-based approach to functionally denervate the human kidneys using radiofrequency ablation technology may provide a safe and effective treatment alternative for resistant hypertension and its adverse consequences. Conclusions Despite the availability of numerous safe and effective pharmacological therapies to treat elevated blood pressure, novel therapeutic approaches are warranted to improve the management and prognosis of patients with refractory hypertension. Several clinical trials are currently conducted and planned to further substantiate the blood pressure lowering efficacy of this novel renal denervation procedure.

  2. The Variable Flow Characteristics for Different Brands of 3-Way Urinary Catheters: Proposing an Alternate and Accurate Standardised Labelling System.

    Science.gov (United States)

    Davis, Niall F; Abdelrahman, Mamoun; Cunnane, Conor V; Cunnane, Eoghan M; Walsh, Michael T; Thornhill, John A

    2016-03-01

    To evaluate an alternative catheter labelling approach for 3-way catheters based on the drainage channel and irrigation channel cross-sectional area (CSA), which impacts catheter flow rate characteristics. Three-way 22Fr catheters from Bard (Bard Limited), Rusch Simplastic (Teleflex Medical), Dover (COVIDIEN), and Rusch Golden were included in the study. Irrigation channel, drainage channel, and overall CSAs were digitally measured with an image-processing program. Irrigation channel and drainage channel flow rates were measured and correlated with their corresponding catheter CSA values. Catheter CSA and French value did not predict flow-rate characteristics, but irrigation channel CSA and drainage channel CSA were predictive. The 22Fr Rusch Simplastic catheter had the largest irrigation channel CSA (2.87 mm(2)) and drainage channel CSA (12.6 mm(2)), and had the greatest irrigation (5.27 ± 0.02 ml/s) and drainage flow rates (14.42 ± 0.22 ml/s). Twenty-two French gauge Rusch Golden catheters had the smallest irrigation channel CSA (1.34 mm(2)) and drainage channel CSA (7.82 mm(2)) and the lowest irrigation (1.83 ± 0.03 ml/s) and drainage flow rates (1.83 ± 0.03 ml/s). An alternative catheter labelling system to include overall CSA, irrigation channel CSA, and drainage channel CSA values would provide more accurate and transparent data relevant to anticipated drainage and irrigation flow rates. The proposed labelling method will assist urologists in selecting 3-way catheters for bladder irrigation. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. CT imaging of complications of catheter ablation for atrial fibrillation

    International Nuclear Information System (INIS)

    Shroff, G.S.; Guirguis, M.S.; Ferguson, E.C.; Oldham, S.A.A.; Kantharia, B.K.

    2014-01-01

    The complication rate following radiofrequency catheter ablation for atrial fibrillation is low (<5%). Complications include pericardial effusion, cardiac tamponade, pulmonary vein stenosis, oesophageal ulceration or perforation, atrio-oesophageal fistula formation, stroke/transient ischaemic attack, phrenic nerve injury, haematoma at the puncture site, and femoral arteriovenous fistula. Among available imaging tools, computed tomography (CT) can be very useful in diagnosing complications of the procedure, particularly in the subacute and delayed stages after ablation. This review illustrates CT imaging of several of the common and uncommon complications of radiofrequency catheter ablation

  4. Indication of the radiofrequency induced lesion size by pre-ablation measurements

    DEFF Research Database (Denmark)

    Stagegaard, Niels; Petersen, Helen Høgh; Chen, Xu

    2005-01-01

    BACKGROUND: During radiofrequency ablation of arrhythmias tissue heating and hence lesion size depend on electrode-tissue contact and cooling of the electrode tip caused by cavitary blood flow. These factors are unique and unknown for each catheter placement in the beating heart. A tool for asses......BACKGROUND: During radiofrequency ablation of arrhythmias tissue heating and hence lesion size depend on electrode-tissue contact and cooling of the electrode tip caused by cavitary blood flow. These factors are unique and unknown for each catheter placement in the beating heart. A tool...... for assessing these factors prior to ablation may indicate the lesion size which will be obtained for any given catheter position. METHODS AND RESULTS: Radiofrequency ablation was performed in vitro on strips of left ventricular porcine myocardium during two different levels of convective cooling (0 or 0.1 m....../s), two different contact pressures (10 or 30 g) and parallel or perpendicular electrode-tissue orientation using 7F 4 mm tip catheters. Prior to ablation the impedance rise (DeltaIMP) caused by the obtained contact and the temperature rise with a 0.6 W 5 s test pulse (DeltaT) were measured. Subsequently...

  5. Reinnervation following catheter-based radio-frequency renal denervation.

    Science.gov (United States)

    Booth, Lindsea C; Nishi, Erika E; Yao, Song T; Ramchandra, Rohit; Lambert, Gavin W; Schlaich, Markus P; May, Clive N

    2015-04-20

    What is the topic of this review? Does catheter-based renal denervation effectively denervate the afferent and efferent renal nerves and does reinnervation occur? What advances does it highlight? Following catheter-based renal denervation, the afferent and efferent responses to electrical stimulation were abolished, renal sympathetic nerve activity was absent, and levels of renal noradrenaline and immunohistochemistry for tyrosine hydroxylase and calcitonin gene-related peptide were significantly reduced. By 11 months after renal denervation, both the functional responses and anatomical markers of afferent and efferent renal nerves had returned to normal, indicating reinnervation. Renal denervation reduces blood pressure in animals with experimental hypertension and, recently, catheter-based renal denervation was shown to cause a prolonged decrease in blood pressure in patients with resistant hypertension. The randomized, sham-controlled Symplicity HTN-3 trial failed to meet its primary efficacy end-point, but there is evidence that renal denervation was incomplete in many patients. Currently, there is little information regarding the effectiveness of catheter-based renal denervation and the extent of reinnervation. We assessed the effectiveness of renal nerve denervation with the Symplicity Flex catheter and the functional and anatomical reinnervation at 5.5 and 11 months postdenervation. In anaesthetized, non-denervated sheep, there was a high level of renal sympathetic nerve activity, and electrical stimulation of the renal nerve increased blood pressure and reduced heart rate (afferent response) and caused renal vasoconstriction and reduced renal blood flow (efferent response). Immediately after renal denervation, renal sympathetic nerve activity and the responses to electrical stimulation were absent, indicating effective denervation. By 11 months after denervation, renal sympathetic nerve activity was present and the responses to electrical stimulation

  6. Percutenous Catheter Ablation of the Accessory Pathway in a Patient with Wolff-Parkinson-White Syndrome Associated with Familial Atrial Fibrillation

    Science.gov (United States)

    Cay, Serkan; Topaloglu, Serkan; Aras, Dursun

    2008-01-01

    Percutenous catheter ablation of the accessory pathway in Wolff-Parkinson-White syndrome is a highly successful mode of therapy. Sudden cardiac arrest survivors associated with WPW syndrome should undergo radiofrequency catheter ablation. WPW syndrome associated with familial atrial fibrillation is a very rare condition. Herein, we describe a case who presented with sudden cardiac arrest secondary to WPW syndrome and familial atrial fibrillation and treated via radiofrequency catheter ablation. PMID:18379660

  7. Percutenous Catheter Ablation of the Accessory Pathway in a Patient with Wolff-Parkinson-White Syndrome Associated with Familial Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Serkan Cay

    2008-04-01

    Full Text Available Percutenous catheter ablation of the accessory pathway in Wolff-Parkinson-White syndrome is a highly successful mode of therapy. Sudden cardiac arrest survivors associated with WPW syndrome should undergo radiofrequency catheter ablation. WPW syndrome associated with familial atrial fibrillation is a very rare condition. Herein, we describe a case who presented with sudden cardiac arrest secondary to WPW syndrome and familial atrial fibrillation and treated via radiofrequency catheter ablation.

  8. Ablation of hypertrophic septum using radiofrequency energy: an alternative for gradient reduction in patient with hypertrophic obstructive cardiomyopathy?

    Science.gov (United States)

    Riedlbauchová, Lucie; Janoušek, Jan; Veselka, Josef

    2013-06-01

    Alcohol septal ablation and surgical myectomy represent accepted therapeutic options for treatment of symptomatic patients with hypertrophic obstructive cardiomyopathy. Long-term experience with radiofrequency ablation of arrhythmogenic substrates raised a question if this technique might be effective for left ventricular outflow tract (LVOT) gradient reduction. We report on a 63-year-old patient with recurrence of symptoms 1 year after alcohol septal ablation (ASA) leading originally to a significant reduction of both symptoms and gradient. Due to a new increase of gradient in the LVOT up to 200 mm Hg with corresponding worsening of symptoms and due to refusal of surgical myectomy by the patient, endocardial radiofrequency ablation of the septal hypertrophy (ERASH) was indicated. Radiofrequency ablation was performed in the LVOT using irrigated-tip ablation catheter; the target site was identified using intracardiac echocardiography and electroanatomical CARTO mapping. ERASH caused an immediate gradient reduction due to hypokinesis of the ablated septum. At 2-month follow-up exam, significant clinical improvement was observed, together with persistent gradient reduction assessed with Doppler echocardiography. Echocardiography and magnetic resonance revealed persistent septal hypokinesis and slight thinning of the ablated region. Septal ablation using radiofrequency energy may be a promising alternative or adjunct to the treatment of hypertrophic obstructive cardiomyopathy. Intracardiac echocardiography and electroanatomical CARTO mapping enable exact lesion placement and preservation of atrioventricular conduction.

  9. Rationale and design of the NO-PARTY trial: near-zero fluoroscopic exposure during catheter ablation of supraventricular arrhythmias in young patients.

    Science.gov (United States)

    Casella, Michela; Dello Russo, Antonio; Pelargonio, Gemma; Bongiorni, Maria Grazia; Del Greco, Maurizio; Piacenti, Marcello; Andreassi, Maria Grazia; Santangeli, Pasquale; Bartoletti, Stefano; Moltrasio, Massimo; Fassini, Gaetano; Marini, Massimiliano; Di Cori, Andrea; Di Biase, Luigi; Fiorentini, Cesare; Zecchi, Paolo; Natale, Andrea; Picano, Eugenio; Tondo, Claudio

    2012-10-01

    Radiofrequency catheter ablation is the mainstay of therapy for supraventricular tachyarrhythmias. Conventional radiofrequency catheter ablation requires the use of fluoroscopy, thus exposing patients to ionising radiation. The feasibility and safety of non-fluoroscopic radiofrequency catheter ablation has been recently reported in a wide range of supraventricular tachyarrhythmias using the EnSite NavX™ mapping system. The NO-PARTY is a multi-centre, randomised controlled trial designed to test the hypothesis that catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system results in a clinically significant reduction in exposure to ionising radiation compared with conventional catheter ablation. The study will randomise 210 patients undergoing catheter ablation of supraventricular tachyarrhythmias to either a conventional ablation technique or one guided by the EnSite NavX™ mapping system. The primary end-point is the reduction of the radiation dose to the patient. Secondary end-points include procedural success, reduction of the radiation dose to the operator, and a cost-effectiveness analysis. In a subgroup of patients, we will also evaluate the radiobiological effectiveness of dose reduction by assessing acute chromosomal DNA damage in peripheral blood lymphocytes. NO-PARTY will determine whether radiofrequency catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system is a suitable and cost-effective approach to achieve a clinically significant reduction in ionising radiation exposure for both patient and operator.

  10. Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography.

    Science.gov (United States)

    Huang, Xingfu; Chen, Yanjia; Huang, Zheng; He, Liwei; Liu, Shenrong; Deng, Xiaojiang; Wang, Yongsheng; Li, Rucheng; Xu, Dingli; Peng, Jian

    2018-06-01

    Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19-76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff-Parkinson-White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99-177) minutes, the reconstruction time was 6.5 ± 2.9 (3-14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6-20) minutes, and the mapping time was 11.7 ± 8.3 (3-36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.

  11. Successful radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia in a patient with dextrocardia due to unilateral pulmonary agenesis: a case report

    Directory of Open Access Journals (Sweden)

    Aksu T

    2015-02-01

    Full Text Available Tolga Aksu, Tumer Erdem Guler, Ebru Golcuk, Ismail Erden, Kazim Serhan Ozcan Department of Cardiology, Kocaeli Derince Education and Research Hospital, Derince, Kocaeli, Turkey Abstract: Radiofrequency catheter ablation of the slow pathway is considered to be the treatment of choice for patients with atrioventricular nodal reentrant tachycardia. We report a 34-year-old female with mirror image dextrocardia due to unilateral pulmonary agenesis who underwent successful slow pathway ablation for typical atrioventricular nodal reentrant tachycardia. Using contrast injection, cardiac anatomy was identified in a short time and successfully ablated. Keywords: dextrocardia, AVNRT, ablation, pulmonary agenesis

  12. Radiofrequency ablation of fast ventricular tachycardia causing an ICD storm in an infant with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper

    2018-04-01

    An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.

  13. Value of local electrogram characteristics predicting successful catheter ablation of left-versus right-sided accessory atrioventricular pathways by radiofrequency current.

    Science.gov (United States)

    Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P

    1995-01-01

    Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.

  14. Mitral valve perforation appearing years after radiofrequency ablation

    DEFF Research Database (Denmark)

    Fisch-Thomsen, Marie; Jensen, Jesper K; Egeblad, Henrik

    2011-01-01

    The case is reported of a young adult with Wolff-Parkinson-White (WPW) syndrome who, three years after a complicated radiofrequency (RF) catheter ablation procedure, developed dyspnea on exertion. Echocardiography revealed severe mitral valve regurgitation caused by a perforation of the posterior...

  15. Visualizing intramyocardial steam formation with a radiofrequency ablation catheter incorporating near-field ultrasound.

    Science.gov (United States)

    Wright, Matthew; Harks, Erik; Deladi, Szabolcs; Fokkenrood, Steven; Zuo, Fei; Van Dusschoten, Anneke; Kolen, Alexander F; Belt, Harm; Sacher, Frederic; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre

    2013-12-01

    Steam pops are a risk of irrigated RF ablation even when limiting power delivery. There is currently no way to predict gas formation during ablation. It would be useful to visualize intramyocardial gas formation prior to a steam pop occurring using near-field ultrasound integrated into a RF ablation catheter. In an in vivo open-chest ovine model (n = 9), 86 lesions were delivered to the epicardial surface of the ventricles. Energy was delivered for 15-60 seconds, to achieve lesions with and without steam pops, based on modeling data. The ultrasound image was compared to a digital audio recording from within the pericardium by a blinded observer. Of 86 lesions, 28 resulted in an audible steam pop. For lesions that resulted in a steam pop compared to those that did not (n = 58), the mean power delivered was 8.0 ± 1.8 W versus 6.7 ± 2.0 W, P = 0.006. A change in US contrast due to gas formation in the tissue occurred in all lesions that resulted in a steam pop. In 4 ablations, a similar change in US contrast was observed in the tissue and RF delivery was stopped; in these cases, no pop occurred. The mean depth of gas formation was 0.9 ± 0.8 mm, which correlated with maximal temperature predicted by modeling. Changes in US contrast occurred 7.6 ± 7.2 seconds before the impedance rise and 7.9 ± 6.2 seconds (0.1-17.0) before an audible pop. Integrated US in an RF ablation catheter is able to visualize gas formation intramyocardially several seconds prior to a steam pop occurring. This technology may help prevent complications arising from steam pops. © 2013 Wiley Periodicals, Inc.

  16. Novel Percutaneous Radiofrequency Ablation of Portal Vein Tumor Thrombus: Safety and Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Mizandari, Malkhaz [High Technology Medical Center, Tbilisi State Medical University (Georgia); Ao, Guokun [The 309 Hospital of People' s Liberation Army, Department on Oncology (China); Zhang Yaojun; Feng Xi [Imperial College London, Department of Surgery and Cancer (United Kingdom); Shen Qiang [The First Minimally Invasive Department of Eastern Hepatobiliary Surgery Hospital (China); Chen Minshan [Cancer Centre of Sun Yat-Sen University, Department of Hepatobiliary Surgery (China); Lau, Wan Yee [Chinese University of Hong Kong, Department of Surgery, Faculty of Medicine (Hong Kong); Nicholls, Joanna; Jiao Long; Habib, Nagy, E-mail: nagy.habib@imperial.ac.uk [Imperial College London, Department of Surgery and Cancer (United Kingdom)

    2013-02-15

    We report our experience of the safety of partial recanalization of the portal vein using a novel endovascular radiofrequency (RF) catheter for portal vein tumor thrombosis. Six patients with liver cancer and tumor thrombus in the portal vein underwent percutaneous intravascular radiofrequency ablation (RFA) using an endovascular bipolar RF device. A 0.035-inch guidewire was introduced into a tributary of the portal vein and through which a 5G guide catheter was introduced into the main portal vein. After manipulation of the guide catheter over the thrombus under digital subtraction angiography, the endovascular RF device was inserted and activated around the thrombus. There were no observed technique specific complications, such as hemorrhage, vessel perforation, or infection. Post-RFA portography showed partial recanalization of portal vein. RFA of portal vein tumor thrombus in patients with hepatocellular carcinoma is technically feasible and warrants further investigation to assess efficacy compared with current recanalization techniques.

  17. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  18. Spectroscopic photoacoustic imaging of radiofrequency ablation in the left atrium

    NARCIS (Netherlands)

    S. Iskander-Rizk (Sophinese); P. Kruizinga (Pieter); A.F.W. van der Steen (Ton); G. van Soest (Gijs)

    2018-01-01

    textabstractCatheter-based radiofrequency ablation for atrial fibrillation has long-term success in 60-70% of cases. A better assessment of lesion quality, depth, and continuity could improve the procedure’s outcome. We investigate here photoacoustic contrast between ablated and healthy atrial-wall

  19. Ex vivo human bile duct radiofrequency ablation with a bipolar catheter.

    Science.gov (United States)

    Atar, Mustafa; Kadayifci, Abdurrahman; Daglilar, Ebubekir; Hagen, Catherine; Fernandez-Del Castillo, Carlos; Brugge, William R

    2018-06-01

    Management of the primary and secondary tumors of the bile ducts still remains as a major clinical challenge. Radiofrequency (RF) ablation (RFA) of these tumors is feasible but the effect of RF energy on the human common bile duct (CBD) and surrounding tissues has not been investigated. This pilot study aimed to determine the relationship between RF energy and the depth of ablation in the normal human CBD. The study was performed on fresh ex vivo human biliary-pancreatic tissue which had been resected for a pancreatic cyst or mass. The study was conducted within 15 min after resection. A bipolar Habib RFA catheter was placed into the middle of the intact CBD, and three different (5, 7, 10 W) power settings were applied over a 90-s period by an RF generator. Gross and histological examinations were performed. The depth of coagulation necrosis in CBD and the effect of RFA on CBD wall and surrounding pancreas tissue were determined by microscopic examination. The study included eight tissue samples. 5 W power was applied to three sites and RFA caused only focal epithelial necrosis limited to the CBD mucosa. 7 and 10 W were applied to five sites and coagulation necrosis occurred in all cases. Microscopically, necrosis was transmural, involved accessory bile duct glands, and extended to the surrounding pancreatic tissue in four of these cases. Macroscopically, RFA resulted in circumferential white-yellowish color change extending approximately 2 cm of the CBD. Bipolar RF energy application with 5 W resulted in limited ablation on CBD wall. However, 7 and 10 W generated tissue necrosis which extended through the CBD wall and into surrounding pancreas tissue. Endoscopic biliary RFA is an effective technique for local biliary tissue ablation but the use of high energy may injure surrounding tissue.

  20. Intra-cardiac echocardiography guided catheter ablation of a right posterior accessory pathway in a patient with Ebstein׳s anomaly

    Directory of Open Access Journals (Sweden)

    Akira Shimane, MD

    2014-12-01

    Full Text Available We report a case of Ebstein׳s anomaly in which radiofrequency catheter ablation of an accessory pathway was successfully performed under intra-cardiac echocardiography. A 50-year-old woman was referred to our hospital for radiofrequency catheter ablation of a paroxysmal supraventricular tachycardia. A 12-lead surface electrocardiogram revealed ventricular pre-excitation associated with type B Wolff–Parkinson–White syndrome. In the baseline electrophysiological study, an orthodromic atrioventricular reciprocating tachycardia with a right posterior accessory pathway was induced. A phased-array intra-cardiac echo probe was positioned in the right atrium to visualize the atrioventricular junction. The key structures for catheter ablation, such as the atrialized right ventricle, atrioventricular junction, and tricuspid valve, were clearly visualized on intra-cardiac echocardiography. Radiofrequency current was successfully delivered at the atrioventricular junction, where a Kent potential was recorded. During a 6-month follow-up period, the patient was free from arrhythmias. The findings in this case suggest that phased-array intra-cardiac echocardiography is useful for ablation of right-sided accessory pathways in patients with Ebstein׳s anomaly.

  1. Successful catheter ablation of ventricular premature complexes from the right atrial side of the atrioventricular septum with good contact force.

    Science.gov (United States)

    Arai, Marina; Fukamizu, Seiji; Kawamura, Iwanari; Miyazawa, Satoshi; Hojo, Rintaro; Sakurada, Harumizu; Hiraoka, Masayasu

    2018-04-01

    The acquisition of good contact force for radiofrequency catheter ablation of ventricular premature complexes (VPCs) originating from the basal septum of the left ventricle (LV) is often difficult. We describe a case of VPCs originating from the basal septum of the LV, which were successfully eliminated by applying radiofrequency at the right atrium (RA) side of the atrioventricular septum (AVS) without causing any significant impairment of atrioventricular conduction because the ablation catheter could obtain better contact force through the RA approach. Moreover, intracardiac echocardiography (ICE) and RA angiography effectively demonstrated the AVS.

  2. Epidemiological profile of Wolff-Parkinson-White syndrome in a general population younger than 50 years of age in an era of radiofrequency catheter ablation.

    Science.gov (United States)

    Lu, Chun-Wei; Wu, Mei-Hwan; Chen, Hui-Chi; Kao, Feng-Yu; Huang, San-Kuei

    2014-07-01

    The prevalence of Wolff-Parkinson-White (WPW) syndrome varies between 0.68 and 1.7/1000. The epidemiological profile may be modified after the introduction of transcatheter interventions. The aim of this study is to investigate the epidemiological trends of the WPW syndrome in a general population during a period with available and reimbursed transcatheter ablation. Data of WPW patients <50 years old were retrieved from our national database (2000-2010). We identified 6086 (61% male) patients, accounting for an overall prevalence of 0.36/1000 with a peak of 0.61/1000 in ages 20-24 years. The risk of death and sudden death was 0.071% and 0.02% per patient-year, respectively. The 42 deaths occurred at a median age of 29 years. Associated congenial heart disease was noted in 158 (2.6%) patients, including 42 with Ebstein's anomaly that increased the mortality risk (P=0.001, OR=8.5). In those without congenital heart disease, myocardial dysfunction occurred in 115 (1.9%) patients and increased the risk of death (P<0.001, OR=10.6) and sudden death. Radiofrequency catheter ablation was performed in 2527 patients at a median age of 25.7 years (4.54% per patient-year, discharge mortality 0.16%); 11 (0.4%) before the age of 5, and 2231 (88%) after the age of 15. Whereas repeated ablation procedures accounted for 6.0% of the procedures, those in Ebstein's patients were 25%. Radiofrequency catheter ablation is already a common treatment for WPW patients, particularly during young adulthood, which accounts for a lower prevalence. Myocardial dysfunction and associated congenital heart disease remain as risks of mortality. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Endoscopic Ultrasound-Guided Perirectal Abscess Drainage without Drainage Catheter: A Case Series

    Directory of Open Access Journals (Sweden)

    Eun Kwang Choi

    2017-05-01

    Full Text Available A perirectal abscess is a relatively common disease entity that occurs as a postsurgical complication or as a result of various medical conditions. Endoscopic ultrasound (EUS-guided drainage was recently described as a promising alternative treatment. Previous reports have recommended placement of a drainage catheter through the anus for irrigation, which is inconvenient to the patient and carries a risk of accidental dislodgement. We report four cases of perirectal abscess that were successfully treated with only one or two 7 F double pigtail plastic stent placements and without a drainage catheter for irrigation.

  4. Symplicity multi-electrode radiofrequency renal denervation system feasibility study.

    Science.gov (United States)

    Whitbourn, Robert; Harding, Scott A; Walton, Antony

    2015-05-01

    The aim of this study was to test the safety and performance of the Symplicity™ multi-electrode radio-frequency renal denervation system which was designed to reduce procedure time during renal denervation. The multi-electrode radiofrequency renal denervation system feasibility study is a prospective, non-randomised, open label, feasibility study that enrolled 50 subjects with hypertension. The study utilises a new renal denervation catheter which contains an array of four electrodes mounted in a helical configuration at 90 degrees from each other to deliver radiofrequency energy simultaneously to all four renal artery quadrants for 60 seconds. The protocol specified one renal denervation treatment towards the distal end of each main renal artery with radiofrequency energy delivered for 60 seconds per treatment. Total treatment time for both renal arteries was two minutes. The 12-month change in office systolic blood pressure (SBP) and 24-hour SBP was -19.2±25.2 mmHg, prenal artery stenosis or hypertensive emergencies occurred. The Symplicity multi-electrode radiofrequency renal denervation system was associated with a significant reduction in SBP at 12 months and minimal complications whilst it also reduced procedure time. NCT01699529.

  5. Percutaneous Hepaticojejunostomy Using a Radiofrequency Wire for Management of a Postoperative Bile Leak

    Energy Technology Data Exchange (ETDEWEB)

    Close, Orrie N. [University of Pittsburgh School of Medicine, Interventional Radiology, Department of Radiology (United States); Akinwande, Olaguoke [Johns Hopkins University, Division of Interventional Radiology (United States); Varma, Rakesh K.; Santos, Ernesto; Kim, Hyun S., E-mail: kevin.kim@yale.edu [University of Pittsburgh School of Medicine, Interventional Radiology, Department of Radiology (United States)

    2017-01-15

    Postoperative biliary complications following extensive hepatic resections are complex, often requiring a multidisciplinary team approach. We describe a case of a free bile duct leak following extended right hepatectomy and surgical hepaticojejunostomy treated with percutaneous transhepatic hepaticojejunostomy in which a radiofrequency guidewire was used to gain enteral access. A modified internal/external biliary catheter was left in place. The patient was enrolled in a benign biliary stricture protocol, and 8 months later, the catheter was removed following a normal cholangiogram and biliary manometric perfusion testing. At 3-month follow-up after catheter removal, the patient is asymptomatic with no clinical, biochemical, or radiographic evidence of biliary leak or obstruction.

  6. Anatomical and procedural determinants of ambulatory blood pressure lowering following catheter-based renal denervation using radiofrequency.

    Science.gov (United States)

    Lauder, Lucas; Ewen, Sebastian; Tzafriri, Abraham R; Edelman, Elazer R; Cremers, Bodo; Kulenthiran, Saarraaken; Ukena, Christian; Linz, Dominik; Kindermann, Ingrid; Tsioufis, Costas; Scheller, Bruno; Böhm, Michael; Mahfoud, Felix

    2018-03-02

    Catheter-based renal sympathetic denervation (RDN) has been introduced to lower blood pressure (BP) and sympathetic activity in patients with uncontrolled hypertension with at best equivocal results. It has been postulated that anatomic and procedural elements introduce unaccounted variability and yet little is known of the impact of renal anatomy and procedural parameters on BP response to RDN. Anatomical parameters such as length and diameter were analyzed by quantitative vascular analysis and the prevalence of accessory renal arteries and renal artery disease were documented in 150 patients with resistant hypertension undergoing bilateral RDN using a mono-electrode radiofrequency catheter (Symplicity Flex, Medtronic). Accessory renal arteries and renal artery disease were present in 56 (37%) and 14 patients (9%), respectively. At 6-months, 24 h-ambulatory BP was reduced by 11/6 mm Hg (p renal arteries (p = 0.543) or renal artery disease (p = 0.598). Patients with at least one main renal artery diameter ≤ 4 mm had a more pronounced reduction of 24 h-ambulatory SBP compared to patients where both arteries were >4 mm (-19 vs. -10 mmHg; p = 0.038). Neither the length of the renal artery nor the number of RF ablations influenced 24 h-ambulatory BP reduction at 6 months. 24 h-ambulatory BP lowering was most pronounced in patients with smaller renal artery diameter but not related to renal artery length, accessory arteries or renal artery disease. Further, there was no dose-response relationship observed with increasing number of ablations. Because little is known of the impact of renal anatomy and procedural parameters on blood pressure (BP) response to renal denervation (RDN), anatomical and procedural data were analyzed in 150 patients undergoing bilateral RDN. BP lowering was most pronounced in patients with smaller renal artery diameter but not related to renal artery length, the presence of renal artery disease or accessory renal

  7. Reliable temperature probe monitoring - Favorable esophageal motion for consistent probe contact during atrial fibrillation catheter ablation

    Directory of Open Access Journals (Sweden)

    Masahiro Esato

    2013-10-01

    Full Text Available Left atrial-esophageal (LA-Eso fistula is now a well-recognized and fatal complication of percutaneous catheter ablation performed using radiofrequency energy for atrial fibrillation (AF. We noted an important esophageal motion during temperature monitoring by a multipolar sensing probe, which could resolve several potential concerns of accurate esophageal temperature measurement and could consequently minimize esophageal injuries including LA-Eso fistulas during catheter ablation for AF.

  8. An improved delivery system for bladder irrigation.

    Science.gov (United States)

    Moslemi, Mohammad K; Rajaei, Mojtaba

    2010-10-05

    Occasionally, urologists may see patients requiring temporary bladder irrigation at hospitals without stocks of specialist irrigation apparatus. One option is to transfer the patient to a urology ward, but often there are outstanding medical issues that require continued specialist input. Here, we describe an improved system for delivering temporary bladder irrigation by utilizing readily available components and the novel modification of a sphygmomanometer blub. This option is good for bladder irrigation in patients with moderate or severe gross hematuria due to various causes. In this prospective study from March 2007 to April 2009, we used our new system in eligible cases. In this system, an irrigant bag with 1 L of normal saline was suspended 80 cm above the indwelled 3-way Foley catheter, and its drainage tube was inserted into the irrigant port of the catheter. To increase the flow rate of the irrigant system, we inserted a traditional sphygmomanometer bulb at the top of the irrigant bag. This closed system was used for continuous bladder irrigation (CBI) in patients who underwent open prostatectomy, transurethral resection of the prostate (TURP), or transurethral resection of the bladder (TURB). This high-pressure system is also used for irrigation during cystourethroscopy, internal urethrotomy, and transurethral lithotripsy. Our 831 eligible cases were divided into two groups: group 1 were endourologic cases and group 2 were open prostatectomy, TURP, and TURB cases. The maximum and average flow rates were evaluated. The efficacy of our new system was compared prospectively with the previous traditional system used in 545 cases. In group 1, we had clear vision at the time of endourologic procedures. The success rate of this system was 99.5%. In group 2, the incidence of clot retention decreased two fold in comparison to traditional gravity-dependent bladder flow system. These changes were statistically significant (P = 0.001). We did not observe any adverse

  9. Catheter ablation of epicardial ventricular tachycardia

    Directory of Open Access Journals (Sweden)

    Takumi Yamada, MD, PhD

    2014-08-01

    Full Text Available Ventricular tachycardias (VTs can usually be treated by endocardial catheter ablation. However, some VTs can arise from the epicardial surface, and their substrate can be altered only by epicardial catheter ablation. There are two approaches to epicardial catheter ablation: transvenous and transthoracic. The transvenous approach through the coronary venous system (CVS has been commonly used because it is easily accessible. However, this approach may be limited by the distribution of the CVS and insufficient radiofrequency energy delivery. Transthoracic epicardial catheter ablation has been developed to overcome these limitations of the transvenous approach. It is a useful supplemental or even preferred strategy to eliminate epicardial VTs in the electrophysiology laboratory. This technique has been applied for scar-related VTs secondary to often non-ischemic cardiomyopathy and sometimes ischemic cardiomyopathy, and idiopathic VTs as the epicardial substrates of these VTs have become increasingly recognized. When endocardial ablation and epicardial ablation through the CVS are unsuccessful, transthoracic epicardial ablation should be the next option. Intrapericardial access is usually obtained through a subxiphoidal pericardial puncture. This approach might not be possible in patients with pericardial adhesions caused by prior cardiac surgery or pericarditis. In such cases, a hybrid procedure involving surgical access with a subxiphoid pericardial window and a limited anterior or lateral thoracotomy might be a feasible and safe method of performing an epicardial catheter ablation in the electrophysiology laboratory. Potential complications associated with this technique include bleeding and collateral damage to the coronary arteries and phrenic nerve. Although the risk of these complications is low, electrophysiologists who attempt epicardial catheter ablation should know the complications associated with this technique, how to minimize their

  10. Phrenic Nerve Injury After Catheter Ablation of Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Jacques Clementy

    2007-01-01

    Full Text Available Phrenic Nerve Injury (PNI has been well studied by cardiac surgeons. More recently it has been recognized as a potential complication of catheter ablation with a prevalence of 0.11 to 0.48 % after atrial fibrillation (AF ablation. This review will focus on PNI after AF ablation. Anatomical studies have shown a close relationship between the right phrenic nerve and it's proximity to the superior vena cava (SVC, and the antero-inferior part of the right superior pulmonary vein (RSPV. In addition, the proximity of the left phrenic nerve to the left atrial appendage has been well established. Independent of the type of ablation catheter (4mm, 8 mm, irrigated tip, balloon or energy source used (radiofrequency (RF, ultrasound, cryothermia, and laser; the risk of PNI exists during ablation at the critical areas listed above. Although up to thirty-one percent of patients with PNI after AF ablation remain asymptomatic, dyspnea remain the cardinal symptom and is present in all symptomatic patients. Despite the theoretical risk for significant adverse effect on functional status and quality of life, short-term outcomes from published studies appear favorable with 81% of patients with PNI having a complete recovery after 7 ± 7 months.Conclusion: Existing studies have described PNI as an uncommon but avoidable complication in patients undergoing pulmonary vein isolation for AF. Prior to ablation at the SVC, antero-inferior RSPV ostium or the left atrial appendage, pacing should be performed before energy delivery. If phrenic nerve capture is documented, energy delivery should be avoided at this site. Electrophysiologist's vigilance as well as pacing prior to ablation at high risk sites in close proximity to the phrenic nerve are the currently available tools to avoid the complication of PNI.

  11. Radiofrequency catheter ablation: Relationship between fluoroscopic time and skin doses according to diagnoses. Basis to establish a quality assurance programme

    International Nuclear Information System (INIS)

    Cotelo, E.; Pouso, J.; Reyes, W.

    2001-01-01

    Radiofrequency Cardiac Catheter Ablation is an Interventional Radiology procedure of great complexity because the cardiologist needs a simultaneous evaluation of fluoroscopic images and electrophysiologic information. Therefore, the procedure typically involves extended fluoroscopic time that may cause radiation-skin injures to patients. Skin doses depend on many factors: equipment design features and its proper use, cardiologist practice, fluoroscopic time, irradiated areas, application of radiation protection recommendations, etc. We evaluate fluoroscopic time in relation to pathology and we estimate skin doses on 233 procedures at the Electrophysiology Laboratory in Casa de Galicia, Montevideo, Uruguay. Significant differences among the medians of fluoroscopic time were found in those procedures depending on diagnoses and results. Higher fluoroscopic time was found in flutter and auricular tachycardia (median was 83 minutes, p=0.0001). In successful procedures (almost 90%), median skin doses was 2.0 Grays (p=0.0001). On the basis of records information, the standard operating procedure and the clinical protocol, expanding close cooperation between the cardiologists and the experts in Radiation Protection will secure the establishment of an Assurance Quality Program. (author)

  12. Thermistor guided radiofrequency ablation of atrial insertion sites in patients with accessory pathways.

    Science.gov (United States)

    Tracy, C M; Moore, H J; Solomon, A J; Rodak, D J; Fletcher, R D

    1995-11-01

    Radiofrequency ablation has gained acceptance in the treatment of patients with symptomatic Wolff-Parkinson-White syndrome. The purpose of this study was to characterize the relation between temperature and other electroconductive parameters in patients undergoing atrial insertion accessory pathway ablation utilizing a thermistor equipped catheter. The mean temperature and power at sites of atrial insertion ablation are lower than has been previously associated with creation of radiofrequency lesions in the ventricle. While high cavitary blood flow in the atrium may result in cooling, the thinner atrial tissue may require less energy to achieve adequate heating than ventricular myocardium.

  13. Three-Catheter Technique for Ablation of Left-Sided Accessory Pathways in Wolff-Parkinson-White is Less Expensive and Equally Successful When Compared to a Five-Catheter Technique.

    Science.gov (United States)

    Capone, Christine A; Ceresnak, Scott R; Nappo, Lynn; Gates, Gregory J; Schechter, Clyde B; Pass, Robert H

    2015-12-01

    To compare the efficacy, safety, and cost-effectiveness of a three-catheter approach with a conventional five-catheter approach for the mapping and ablation of supraventricular tachycardia in pediatric patients with Wolff-Parkinson-White Syndrome (WPW) and concealed accessory pathways (APs). A retrospective review from 2008 to 2012 of patients less than 21 years with WPW who underwent a three-catheter radiofrequency (RF) ablation of a left-sided AP (ablation, right ventricular [RV] apical, and coronary sinus [CS] decapolar catheters) was performed. The three-catheter group was compared to a control group who underwent a standard five-catheter (ablation, RV apical, CS decapolar, His catheter, and right atrial catheter) ablation for the treatment of left-sided WPW or concealed AP. Demographics, ablation outcomes, and costs were compared between groups. Twenty-eight patients met inclusion criteria with 28 control patients. The groups did not differ in gender, age, weight, or body surface area. Locations of the AP on the mitral annulus were similar between the groups. All patients were ablated via transseptal approach. Note that 28 of 28 in the three-catheter group (100%) and 27 of 28 (96%) controls were acutely successfully ablated (P = 0.31). No complications were encountered. There was no difference in procedural time, time to loss of AP conduction, or number of RF applications. Use of the three-catheter technique resulted in a total savings of $2,465/case, which includes the $680 savings from using fewer catheters as well as the savings from a shortened procedure time. Ablation in patients with WPW and a left-sided AP can be performed using three catheters with similar efficacy and safety while offering significant cost savings compared to a conventional five-catheter approach. © 2015 Wiley Periodicals, Inc.

  14. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    International Nuclear Information System (INIS)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan

    2004-01-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications

  15. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan [Asan Medical Center, Seoul (Korea, Republic of)

    2004-04-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications.

  16. Development of a Novel Shock Wave Catheter Ablation System

    Science.gov (United States)

    Yamamoto, H.; Hasebe, Yuhi; Kondo, Masateru; Fukuda, Koji; Takayama, Kazuyoshi; Shimokawa, Hiroaki

    Although radio-frequency catheter ablation (RFCA) is quite effective for the treatment tachyarrhythmias, it possesses two fundamental limitations, including limited efficacy for the treatment of ventricular tachyarrhythmias of epicardial origin and the risk of thromboembolism. Consequently, new method is required, which can eradicate arrhythmia source in deep part of cardiac muscle without heating. On the other hand, for a medical application of shock waves, extracorporeal shock wave lithotripter (ESWL) has been established [1]. It was demonstrated that the underwater shock focusing is one of most efficient method to generate a controlled high pressure in a small region [2]. In order to overcome limitations of existing methods, we aimed to develop a new catheter ablation system with underwater shock waves that can treat myocardium at arbitrary depth without causing heat.

  17. Impact of Lesion Placement on Efficacy and Safety of Catheter-Based Radiofrequency Renal Denervation.

    Science.gov (United States)

    Mahfoud, Felix; Tunev, Stefan; Ewen, Sebastian; Cremers, Bodo; Ruwart, Jennifer; Schulz-Jander, Daniel; Linz, Dominik; Davies, Justin; Kandzari, David E; Whitbourn, Robert; Böhm, Michael; Melder, Robert J

    2015-10-20

    Insufficient procedural efficacy has been proposed to explain nonresponse to renal denervation (RDN). The aim of this study was to examine the impact of different patterns of lesion placements on the efficacy and consistency of catheter-based radiofrequency RDN in pigs. The impact of increasing number of lesions versus location of RDN was investigated in a porcine model (Group 1; n = 51). The effect of treating the main artery, the branches, and the 2 combined was compared in Group 2 (n = 48). The durability of response and safety of combined treatment of the main artery plus branches was examined in Group 3 (n = 16). Renal norepinephrine (NE) tissue content and renal cortical axon density were assessed. Increasing the number of RF lesions (4, 8, and 12) in the main renal artery was not sufficient to yield a clear dose-response relationship on NE content and axon density. In contrast, targeted treatment of the renal artery branches or distal segment of the main renal artery resulted in markedly less variability of response and significantly greater reduction of both NE and axon density than conventional treatment of only the main renal artery. Combination treatment (main artery plus branches) produced the greatest change in renal NE and axon density with the least heterogeneity. The changes were durable through 28 days post-treatment. These data provide the rationale for investigation of an optimized approach for RDN in future clinical studies. This may have profound implications for the clinical application of RDN, as this approach may not only achieve greater reductions in sympathetic activity but also reduce treatment effect variability. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Rapid totally diverting loop sigmoid colostomy with noncontaminating rectal irrigation.

    Science.gov (United States)

    Sachatello, C R; Maull, K I

    1977-08-01

    Loop sigmoid colostomy employing a stapling device and catheter irrigation of the distal segment is less time-consuming and has lest potential for contamination than the standard double-barrel colostomy. Unlike the standard loop colostomy, it is totally diverting.

  19. Direct measurement of the lethal isotherm for radiofrequency ablation of myocardial tissue.

    Science.gov (United States)

    Wood, Mark; Goldberg, Scott; Lau, Melissa; Goel, Aneesh; Alexander, Daniel; Han, Frederick; Feinstein, Shawn

    2011-06-01

    The lethal isotherm for radiofrequency catheter ablation of cardiac myocardium is widely accepted to be 50°C, but this has not been directly measured. The purpose of this study was to directly measure the tissue temperature at the edge of radiofrequency lesions in real time using infrared thermal imaging. Fifteen radiofrequency lesions of 6 to 240 seconds in duration were applied to the left ventricular surface of isolated perfused pig hearts. At the end of radiofrequency delivery, a thermal image of the tissue surface was acquired with an infrared camera. The lesion was then stained and an optical image of the lesion was obtained. The thermal and optical images were electronically merged to allow determination of the tissue temperature at the edge of the lesion at the end of radiofrequency delivery. By adjusting the temperature overlay display to conform with the edge of the radiofrequency lesion, the lethal isotherm was measured to be 60.6°C (interquartile ranges, 59.7° to 62.4°C; range, 58.1° to 64.2°C). The areas encompassed by the lesion border in the optical image and the lethal isotherm in the thermal image were statistically similar and highly correlated (Spearman ρ=0.99, Pradiofrequency delivery or to lesion size (both P>0.64). The areas circumscribed by 50°C isotherms were significantly larger than the areas of the lesions on optical imaging (P=0.002). By direct measurement, the lethal isotherm for cardiac myocardium is near 61°C for radiofrequency energy deliveries radiofrequency ablation is important to clinical practice as well as mathematical modeling of radiofrequency lesions.

  20. Idiopathic premature ventricular contractions and ventricular tachycardias originating from the vicinity of tricuspid annulus: Results of radiofrequency catheter ablation in thirty-five patients

    Directory of Open Access Journals (Sweden)

    Yue-Chun Li

    2012-07-01

    Full Text Available Abstract Background In recent years, catheter ablation has increasingly been used for ablation of idiopathic premature ventricular complexes (PVCs or ventricular tachycardias (IVTs. However, the mapping and catheter ablation of the arrhythmias originating from the vicinity of tricuspid annulus (TA may not be fully understood. This study aimed to investigate electrophysiologic characteristics and effects of radiofrequency catheter ablation (RFCA for patients with symptomatic PVCs and IVTs originating from the vicinity of TA. Methods Characteristics of body surface electrocardiogram (ECG and electrophysiologic recordings were analyzed in 35 patients with symptomatic PVCs/ IVTs originating from the vicinity of TA. RFCA was performed using pace mapping and activation mapping. Results Among the 35 patients with PVCs/IVTs arising from the vicinity of TA, complete elimination of PVCs/IVTs could be achieved by RFCA in 32 patients (success rate 91.43% during a median follow-up period of 21 months. PVCs/IVTs originating from the vicinity of TA had distinctive ECG characteristics that were useful for identifying the precise origin. An rS pattern was recorded in lead V1 in 93.1% of patients with PVCs/IVTs from the free wall of TA, vs 16.7% of patients with PVCs/IVTs from the septal TA, whereas a QS pattern in lead V1 occurred in 83.3% of patients with PVCs/IVTs from the septal TA vs 6.9% of patients with PVCs from the free wall of the TA. The precordial R wave transition occurred by lead V3 or earlier in all patients with PVCs/IVTs originating from the septal portion of the TA, as compared to transition beyond V3 in all patients with PVCs/IVTs from the free wall of the TA. Conclusions RFCA is an effective curative therapy for symptomatic PVCs/IVTs originating from the vicinity of TA. There are specific characteristics in ECG and the ablation site could be located by ECG analysis.

  1. Radiofrequency Thermal Ablation Heat Energy Transfer in an Ex-Vivo Model.

    Science.gov (United States)

    Thakur, Shivani; Lavito, Sandi; Grobner, Elizabeth; Grobner, Mark

    2017-12-01

    Little work has been done to consider the temperature changes and energy transfer that occur in the tissue outside the vein with ultrasound-guided vein ablation therapy. In this experiment, a Ex-Vivo model of the human calf was used to analyze heat transfer and energy degradation in tissue surrounding the vein during endovascular radiofrequency ablation (RFA). A clinical vein ablation protocol was used to determine the tissue temperature distribution in 10 per cent agar gel. Heat energy from the radiofrequency catheter was measured for 140 seconds at fixed points by four thermometer probes placed equidistant radially at 0.0025, 0.005, and 0.01 m away from the RFA catheter. The temperature rose 1.5°C at 0.0025 m, 0.6°C at 0.005 m, and 0.0°C at 0.01 m from the RFA catheter. There was a clinically insignificant heat transfer at the distances evaluated, 1.4 ± 0.2 J/s at 0.0025 m, 0.7 ± 0.3 J/s at 0.0050 m, and 0.3 ± 0.0 J/s at 0.01 m. Heat degradation occurred rapidly: 4.5 ± 0.5 J (at 0.0025 m), 4.0 ± 1.6 J (at 0.0050 m), and 3.9 ± 3.6 J (at 0.01 m). Tumescent anesthesia injected one centimeter around the vein would act as a heat sink to absorb the energy transferred outside the vein to minimize tissue and nerve damage and will help phlebologists strategize options for minimizing damage.

  2. Use of bipolar radiofrequency catheter ablation in treatment of cardiac arrhythmias.

    Science.gov (United States)

    Soucek, Filip; Starek, Zdenek

    2018-05-23

    Background Arrhythmia management is a complex process involving both pharmacological and non-pharmacological approaches. Radiofrequency ablation is the pillar of non-pharmacological arrhythmia treatment. Unipolar ablation is considered to be the gold standard in the treatment of the majority of arrhythmias; however, its efficacy is limited to specific cases. In particular, the creation of deep or transmural lesions to eliminate intramurally originating arrhythmias remains inadequate. Bipolar ablation is proposed as an alternative to overcome unipolar ablation boundaries. Results Despite promising results gained from in vitro and animal studies showing that bipolar ablation is superior in creating transmural lesions, the use of bipolar ablation in daily clinical practice is limited. Several studies have been published showing that bipolar ablation is effective in the treatment of clinical arrhythmias after failed unipolar ablation, however there is inconsistency regarding safety of bipolar ablation within the available research papers. According to research evidence the most common indications for bipolar ablation use are ventricular originating rhythmic disorders in patients with structural heart disease resistant to standard radiofrequency ablation. Conclusions To allow wider clinical application the efficiency and safety of bipolar ablation need to be verified in future studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. The role of Multidetector CT in the evaluation of the left atrium and pulmonary veins anatomy before and after radio-frequency catheter ablation for atrial fibrillation. Preliminary results and work in progress.Technical note

    International Nuclear Information System (INIS)

    Centoze, Maurizio; Della Sala, Sabino Walter; Dalla Palma, Francesco; Del Greco, Maurizio; Marini, Massimiliano; Nollo, Giandomenico; Ravelli, Flavia

    2005-01-01

    Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward [it

  4. Observation of the efficacy of radiofrequency catheter ablation on patients with different forms of atrial fibrillation.

    Science.gov (United States)

    Zhao, R-C; Han, W; Han, J; Yu, J; Guo, J; Fu, J-L; Li, Z; Zhao, R-Z

    2016-10-01

    To study the efficacy and safety of radiofrequency catheter ablation (RFCA) in patients with different forms of atrial fibrillation. By retrospective analysis, we summarize 720 cases, where patients diagnosed with atrial fibrillation in our hospital were treated with RFCA from February 2010 to October 2014. Among the cases, 425 were diagnosed with paroxysmal atrial fibrillation and 295 with non-paroxysmal atrial fibrillation (including persistent atrial fibrillation and permanent atrial fibrillation). All patients were followed up until June 2015 to compare and analyze the differences in operation success rates, complications and recurrence rates. 395 cases (92.9%) of paroxysmal atrial fibrillation and 253 cases (85.8%) with non-paroxysmal atrial fibrillation were subject to surgery and followed up. The age of onset, disease course, underlying diseases, left atrial diameter and combined anti-arrhythmics of patients with paroxysmal atrial fibrillation were lower than those of patients with non-paroxysmal atrial fibrillation, and the differences were statistically significant (p success rate of the first ablation was higher than that of non-paroxysmal atrial fibrillation. Procedure time, procedure method, complications and recurrence rate of patients with paroxysmal atrial fibrillation were lower than those of non-paroxysmal atrial fibrillation group, and the differences were statistically significant (p failure caused by atrial fibrillation in the two groups, the difference was not statistically significant (Apoplexy: p = 0.186; Heart failure: p = 0.170). The individual ablation success rate was higher for paroxysmal atrial fibrillation, and long-term follow-up showed that the occurrence of apoplexy and heart failure was not different from the non-paroxysmal atrial fibrillation group.

  5. Radiofrequency Catheter Ablation for Atrial Fibrillation Elicited "Jackhammer Esophagus": A New Complication Due to Vagal Nerve Stimulation?

    Science.gov (United States)

    Tolone, Salvatore; Savarino, Edoardo; Docimo, Ludovico

    2015-10-01

    Radiofrequency catheter ablation (RFCA) is a potentially curative method for treatment of highly symptomatic and drug-refractory atrial fibrillation (AF). However, this technique can provoke esophageal and nerve lesion, due to thermal injury. To our knowledge, there have been no reported cases of a newly described motor disorder, the Jackhammer esophagus (JE) after RFCA, independently of GERD. We report a case of JE diagnosed by high-resolution manometry (HRM), in whom esophageal symptoms developed 2 weeks after RFCA, in absence of objective evidence of GERD. A 65-year-old male with highly symptomatic, drug-refractory paroxysmal AF was candidate to complete electrical pulmonary vein isolation with RFCA. Prior the procedure, the patient underwent HRM and impedance-pH to rule out GERD or hiatal hernia presence. All HRM parameters, according to Chicago classification, were within normal limits. No significant gastroesophageal reflux was documented at impedance pH monitoring. Patient underwent RFCA with electrical disconnection of pulmonary vein. After two weeks, patient started to complain of dysphagia for solids, with acute chest-pain. The patient repeated HRM and impedance-pH monitoring 8 weeks after RFCA. HRM showed in all liquid swallows the typical spastic hypercontractile contractions consistent with the diagnosis of JE, whereas impedance-pH monitoring resulted again negative for GERD. Esophageal dysmotility can represent a possible complication of RFCA for AF, probably due to a vagal nerve injury, and dysphagia appearance after this procedure must be timely investigated by HRM.

  6. The role of the accessory pathway radiofrequency catheter ablation in the secondary prevention of the malignant tachyarrhythmias in patients with Wolff-Parkinson-White syndrome

    Directory of Open Access Journals (Sweden)

    Mujović Nebojša

    2010-01-01

    Full Text Available Background/Aim. The occurrence of atrial fibrillation (AF in the presence of an accessory pathway (AP that conducts rapidly is potentially lethal because the rapid ventricular response may lead to ventricular fibrillation (VF. The aim of the study was to determine long-term efficacy of AP catheter-ablation using radiofrequency (RF current in secondary prevention of VF in WPW patients. Methods. Study included a total of 192 symptomatic WPW patients who underwent RF catheter-ablation of AP in our institution from 1994 to 2007 and were available for clinical follow-up for more than 3 months after procedure. Results. Before ablation, VF was recorded in total of 27 patients (14.1%. In 14 of patients (51.9% VF was the first clinical manifestation of WPW syndrome. A total of 35 VF episodes were identified in 27 patients. The occurrence of VF was preceded by physical activity or emotional stress in 17.1% of cases, by alcohol abuse in 2.9% and by inappropriate intravenous drug administration in 28.6%. In addition, no clear precipitating factor was identified in 40% of VF cases, while informations about activities preceding 11.4% of VF episodes were not available. The follow-up of 5.7 ± 3.3 years was obtained in all of 27 VF patients. Of the 20 patients who underwent successful AP ablation, all were alive, without syncope or ventricular tachyarrhythmias during long-term follow-up. In 4 of 7 unsuccessfully treated patients, recurrence of supraventricular tachycardia and/or preexcited atrial fibrillation were recorded; one of these patients suddenly died of VF, 6 years after procedure. Conclusion. In significant proportion of WPW patients, VF was the first clinical manifestation of WPW syndrome, often precipitated by physical activity, emotional stress or inappropriate drug administration. Successful elimination of AP by percutaneous RF catheter-ablation is highly effective in secondary prevention of life-threatening tachyarrhythmias in patients with

  7. Creation of transcatheter aortopulmonary and cavopulmonary shunts using magnetic catheters: feasibility study in swine.

    Science.gov (United States)

    Levi, Daniel S; Danon, Saar; Gordon, Brent; Virdone, Nicky; Vinuela, Fernando; Shah, Sanjay; Carman, Greg; Moore, John W

    2009-05-01

    Surgical shunts are the basic form of palliation for many types of congenital heart disease. The Glenn shunt (superior cavopulmonary connection) and central shunt (aortopulmonary connection) represent surgical interventions that could potentially be accomplished by transcatheter techniques. We sought to investigate the efficacy of using neodymium iron boron (NdFeB) magnetic catheters to create transcatheter cavopulmonary and aortopulmonary shunts. NdFeB magnets were machined and integrated into catheters. "Target" catheters were placed in the pulmonary arteries (PAs), and radiofrequency "perforation" catheters were placed in either the descending aorta (DAo) for central shunts or the superior vena cava (SVC) for Glenn shunts. The magnet technique or "balloon target" method was used to pass wires from the DAo or the SVC into the PA. Aortopulmonary and cavopulmonary connections were then created using Atrium iCAST covered stents. Magnet catheters were used to perforate the left pulmonary artery from the DAo, thereby establishing a transcatheter central shunt. Given the orientation of the vasculature, magnetic catheters could not be used for SVC-to-PA connections; however, perforation from the SVC to the right pulmonary artery was accomplished with a trans-septal needle and balloon target. Transcatheter Glenn or central shunts were successfully created in four swine.

  8. Catheter ablation as a treatment of atrioventricular block.

    Science.gov (United States)

    Tuohy, Stephen; Saliba, Walid; Pai, Manjunath; Tchou, Patrick

    2018-01-01

    Symptomatic second-degree atrioventricular (AV) block is typically treated by implantation of a pacemaker. An otherwise healthy AV conduction system can nevertheless develop AV block due to interference from junctional extrasystoles. When present with a high burden, these can produce debilitating symptoms from AV block despite an underlying normal AV node and His-Purkinje system properties. The purpose of this study was to describe a catheter ablation approach for alleviating symptomatic AV block due to a ventricular nodal pathway interfering with AV conduction. Common clinical monitoring techniques such as Holter and event recorders were used. Standard electrophysiological study techniques using multipolar recording and ablation catheters were utilized during procedures. A 55-year-old woman presented with highly symptomatic, high-burden second-degree AV block due to concealed and manifest junctional premature beats. Electrophysiological characteristics indicated interference of AV conduction due to a concealed ventricular nodal pathway as the cause of the AV block. The patient's AV nodal and His-Purkinje system conduction characteristics were otherwise normal. Radiofrequency catheter ablation of the pathway was successful in restoring normal AV conduction and eliminating her clinical symptoms. Pathways inserting into the AV junction can interfere with AV conduction. When present at a high burden, this type of AV block can be highly symptomatic. Catheter ablation techniques can be used to alleviate this type of AV block and restore normal AV conduction. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Interventional MRA: concepts for active visualization of catheters and stents

    International Nuclear Information System (INIS)

    Quick, H.H.; Ladd, M.E.

    2003-01-01

    A precondition to safe guidance of vascular guidewires and catheters during the course of magnetic resonance (MR)-guided vascular intervention is a high-contrast visualization of the instruments. The integration of miniature radiofrequency (RF) coils and coaxial cables into guidewires and catheters enables the reception of RF signal from the lumen of blood vessels, and thus the active visualization of the instruments. Moreover, metallic vascular implants (stents) can be modified to act as intravascular RF antennas that inductively couple their RF signal to a conventional surface RF coil. Such stent resonators show signal amplification inside the lumen of the stent and thus can be visualized with high contrast in MR images. Furthermore, once such a device has been implanted, the method offers the potential for non-invasive long-term follow-up of the stent patency. (orig.) [de

  10. Efficacy and Safety of Uninterrupted Low-Intensity Warfarin for Radiofrequency Catheter Ablation of Atrial Fibrillation in the Elderly.

    Science.gov (United States)

    Xing, Yangbo; Xu, Buyun; Xu, Chao; Peng, Fang; Yang, Biao; Qiu, Yufang; Sun, Yong; Wang, Shengkai; Guo, Hangyuan

    2017-09-01

    No previous studies exist investigating the optimal intensity of uninterrupted anticoagulation with warfarin during radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) in the elderly. Evaluate the efficacy and safety of continuous low-intensity warfarin therapy throughout the periprocedural period of RFCA for AF in the elderly. This is a prospective randomized study. We enrolled AF patients (age ≥ 70 years) who underwent first-time RFCA for AF. Enrolled patients were randomized to group A and group B. The international normalized ratios before ablation were maintained at 1.5 to 2.0 and 2.0 to 2.5 in group A and B, respectively. Primary end points were periprocedural thromboembolic complications and major bleeding. Secondary end points included periprocedural asymptomatic cerebral emboli (ACE) and minor bleeding. A total of 101 patients were enrolled in our study (group A: 52; group B: 49). Baseline characteristics were well balanced between the 2 groups. Only 1 patient suffered from stroke in group B. No major bleeding events occurred in either group. The incidence of new ACE lesions was comparable between the 2 groups (11.5% vs 8.2%, P = 0.82). Minor bleeding occurred in 1 of 52 (1.9%) patients in group A and in 5 of 49 (10.2%) patients in group B ( P = 0.10). Uninterrupted low-intensity warfarin for RFCA of AF might be as effective as standard-intensity warfarin in preventing periprocedural thromboembolic complications and might be associated with fewer bleeding events in the elderly.

  11. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    International Nuclear Information System (INIS)

    Wolf, Florian; Ourednicek, Petr; Loewe, Christian; Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne; Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes; Feuchtner, Gudrun M.

    2010-01-01

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  12. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.a [Department of Radiology, Medical University of Vienna, Vienna (Austria); Ourednicek, Petr [Philips Medical Systems, Prague (Czech Republic); Loewe, Christian [Department of Radiology, Medical University of Vienna, Vienna (Austria); Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne [Department of Cardiology, Medical University of Vienna, Vienna (Austria); Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes [Department of Radiology, Medical University of Vienna, Vienna (Austria); Feuchtner, Gudrun M. [Department of Radiology, Innsbruck Medical University, Innsbruck (Austria); Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2010-08-15

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  13. Catheter Ablation of Ectopic Atrial Tachycardia Originating from the Left Atrial Appendage using CARTOMERGE® System

    Directory of Open Access Journals (Sweden)

    Masahiko Goya, MD

    2008-01-01

    Full Text Available A 70-year-old woman was referred because of drug resistant and daily incessant palpitation attack. She had undergone two previous unsuccessful radiofrequency catheter ablations at another hospital. The physical examination, chest X-ray, and echocardiogram were all normal. The 12-lead ECG during tachycardia showed narrow QRS, short PR tachycardia and negative polarity of the P wave in leads I and aVL (Fig. 1A. The ECG monitor showed incessant tachycardia with warming-up phenomenon. Three dimensional electroanatomical map integrated with CT imaging (CARTOMERGE®, Biosense Webster Inc. clearly revealed the radial activation pattern originating from the basalo-postero-inferior aspect of the left atrial appendage. Radiofrequency energy application at this site eliminated tachycardia permanently.

  14. Recurrence of atrial fibrillation after successful radiofrequency catheter ablation of accessory pathway in patients with Wolff-Parkinson-White syndrome

    Directory of Open Access Journals (Sweden)

    Mujović Nebojša

    2010-01-01

    Full Text Available Introduction. Paroxysmal atrial fibrillation (AF occurs in 11.5-39% of the patients with Wolff-Parkinson-White (WPW syndrome and frequently, but not always, disappears after successful accessory pathway (AP ablation. Objective. To determine AF recurrence rate, time to AF recurrence and predictors of AF recurrence after radiofrequency (RF catheter-ablation of AP in WPW-patients with AF. Methods. Data from 245 consecutive patients with WPW-syndrome who underwent RF catheter-ablation of AP were analyzed. A total of 52 patients (43 men, mean age: 42.5±14.1 years with preablation history of spontaneous AF were followed up after definitive AP ablation. At baseline, structural heart disease and comorbidities were diagnosed in 19.2% and 21.2% of the patients, respectively. Results. During the follow-up of 5.2±3.7 years, 3 patients (5.7% died; one of these patients, previously known for recurrent AF, died from ischaemic stroke. Symptomatic recurrence of AF was detected in 9 of 52 patients (17.3%. In 66.7% of these patients, AF recurrence was identified in the first year following the procedure. Kaplan-Meier analysis demonstrated that freedom from recurrent AF after 3 months was 94.2%, after 1 year 87.5% and after 4 years 84.3%. Univariate analysis showed that older age (p=0.023, presence of structural heart disease (p=0.05 and dilated left atrium (p=0.013 were significantly related to AF recurrence. However, using multivariate Cox regression, older age was the only independent predictor of AF recurrence (HR=2.44 for every life decade; p=0.006. Analysis of ROC curves showed that, after the age of 36, the risk of AF recurrence abruptly increased. Conclusion. Symptomatic recurrence of AF was detected in 17% of WPW-patients after definite RF ablation of AP. The timedependent occurrence of AF recurrences and age-dependent increase in the rate of AF recurrence were identified. Closer follow-up and/or extension of drug therapy in older patients, at least in

  15. Habib EndoHPB: a novel endobiliary radiofrequency ablation device. An experimental study.

    Science.gov (United States)

    Zacharoulis, Dimitris; Lazoura, Olga; Sioka, Eleni; Potamianos, Spyros; Tzovaras, George; Nicholls, Joanna; Koukoulis, George; Habib, Nagy

    2013-02-01

    The Habib EndoHPB is a bipolar radiofrequency (RF) catheter developed to be introduced across malignant strictures of the bile ducts, so that RF energy can locally ablate the tumor prior to stent placement. This experiment aims to assess the ability of the catheter to coagulate the wall of the common bile duct (CBD) in a porcine model, to establish power requirement and time parameters and correlate them to the depth of thermal injury, and to assess the ease of operation of the device. The CBD was catheterized using the device in 20 pigs. RF energy was applied to the CBD wall with various generator settings. The pigs were sacrificed 24 hr after the application and the CBD was excised for histological analysis. The device was easy to handle. Statistically significant correlations between the power, the time of RF application, and the thermal injury depth were found. The Habib EndoHPB catheter can effectively deliver RF energy intraluminally in the porcine CBD. Clinical studies are warranted in order to define proper settings for safe and efficient use in malignant biliary obstruction.

  16. [Catheter ablation of ectopic incessant atrial tachycardia using radiofrequency. Reversion of tachycardiomyopathy].

    Science.gov (United States)

    de Paola, A A; Mendonça, A; Balbão, C E; Tavora, M Z; da Silva, R M; Hara, V M; Guiguer Júnior, N; Vattimo, A C; Souza, I A; Portugal, O P

    1993-10-01

    A 8-year-old female patient with refractory incessant atrial tachycardia, very symptomatic and with left ventricular ejection fraction of 0.25. Electrophysiological study and endocardial mapping localized the site of the origin of atrial tachycardia in the superior right atrium. In this site 2 applications of radiofrequency current (25V, 20 and 50 seconds) resulted in termination of the atrial tachycardia. She was discharged off antiarrhythmic drugs and after 2 months ejection fraction was 0.52. She was completely asymptomatic 6 months after ablation procedure.

  17. The Nelaton Catheter Guard for Safe and Effective Placement of Subdural Drain for Two-Burr-Hole Trephination in Chronic Subdural Hematoma: A Technical Note.

    Science.gov (United States)

    Fichtner, Jens; Beck, Jürgen; Raabe, A; Stieglitz, Lennart Henning

    2015-09-01

    For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain. Georg Thieme Verlag KG Stuttgart · New York.

  18. Renal denervation using catheter-based radiofrequency ablation with temperature control: renovascular safety profile and underlying mechanisms in a hypertensive canine model.

    Science.gov (United States)

    Li, Huijie; Yu, Hang; Zeng, Chunyu; Fang, Yuqiang; He, Duofen; Zhang, Xiaoqun; Wen, Chunlan; Yang, Chengming

    2015-01-01

    Renal denervation is a novel method for hypertension treatment. In this study, we aimed to investigate the safety and efficacy of radiofrequency ablation (RFA) at ablation temperatures of 45 °C or 50 °C and its possible mechanisms. A hypertensive canine model was established by abdominal aortic constriction in 20 healthy hybrid dogs. These dogs were then randomly assigned to the treatment and the control groups, with dogs in the treatment group further randomly assigned to receive RFA at ablation temperatures of 45 °C or 50 °C. In the treatment group, RFA was performed at 1 month after modeling; renal angiography was performed at 2 months after ablation. The arterial vessels of the dogs were examined histologically with hematoxylin and eosin staining. Changes in blood pressure in the foreleg and whole-body norepinephrine spillover rate were also assessed. No arterial stenosis, dissection, thrombosis or other abnormalities were detected in the treated vessels by renal angiography, yet histology results showed minimal to mild renal arterial injury. Renal denervation resulted in a marked decrease in the whole-body norepinephrine spillover rate (p 0.05). Renal denervation can be performed without acute major adverse events, using catheter-based RFA with temperature control. The procedure was feasible in reducing blood pressure by at least partially inhibiting sympathetic drive and systemic sympathetic outflow.

  19. Perivascular radiofrequency renal denervation lowers blood pressure and ameliorates cardiorenal fibrosis in spontaneously hypertensive rats

    Science.gov (United States)

    Zhang, Yan; Su, Linan; Zhang, Yunrong; Wang, Qiang; Yang, Dachun; Li, De; Yang, Yongjian; Ma, Shuangtao

    2017-01-01

    Background Catheter-based renal denervation (RDN) is a promising approach to treat hypertension, but innervation patterns limit the response to endovascular RDN and the post-procedural renal artery narrowing or stenosis questions the endovascular ablation strategy. This study was performed to investigate the anti-hypertensive and target organ protective effects of perivascular RDN in spontaneously hypertensive rats (SHR). Methods SHR and normotensive Wistar-Kyoto (WKY) rats were divided into sham group (n = 10), radiofrequency ablation group (n = 20) in which rats received bilateral perivascular ablation with radiofrequency energy (2 watts), and chemical (10% phenol in 95% ethanol) ablation group (n = 12). The tail-cuff blood pressure was measured before the ablation and on day 14 and day 28 after the procedure. The plasma levels of creatinine, urea nitrogen, and catecholamines, urinary excretion of electrolytes and protein, and myocardial and glomerular fibrosis were analyzed and compared among the groups on day 28 after the procedure. Results We identified that 2-watt is the optimal radiofrequency power for perivascular RDN in rats. Perivascular radiofrequency and chemical ablation achieved roughly comparable blood pressure reduction in SHR but not in WKY on day 14 and day 28 following the procedure. Radiofrequency-mediated ablation substantially destroyed the renal nerves surrounding the renal arteries of both SHR and WKY without damaging the renal arteries and diminished the expression of tyrosine hydroxylase, the enzyme marker for postganglionic sympathetic nerves. Additionally, perivascular radiofrequency ablation also decreased the plasma catecholamines of SHR. Interestingly, both radiofrequency and chemical ablation decreased the myocardial and glomerular fibrosis of SHR, while neither increased the plasma creatinine and blood urea nitrogen nor affected the urinary excretion of electrolytes and protein when compared to sham group. Conclusions Radiofrequency

  20. Comparison of microbubble presence in the right heart during mechanochemical and radiofrequency ablation for varicose veins.

    Science.gov (United States)

    Moon, K H; Dharmarajah, B; Bootun, R; Lim, C S; Lane, Tra; Moore, H M; Sritharan, K; Davies, A H

    2017-07-01

    Objective Mechanochemical ablation is a novel technique for ablation of varicose veins utilising a rotating catheter and liquid sclerosant. Mechanochemical ablation and radiofrequency ablation have no reported neurological side-effect but the rotating mechanism of mechanochemical ablation may produce microbubbles. Air emboli have been implicated as a cause of cerebrovascular events during ultrasound-guided foam sclerotherapy and microbubbles in the heart during ultrasound-guided foam sclerotherapy have been demonstrated. This study investigated the presence of microbubbles in the right heart during varicose vein ablation by mechanochemical abaltion and radiofrequency abaltion. Methods Patients undergoing great saphenous vein ablation by mechanochemical abaltion or radiofrequency ablation were recruited. During the ablative procedure, the presence of microbubbles was assessed using transthoracic echocardiogram. Offline blinded image quantification was performed using International Consensus Criteria grading guidelines. Results From 32 recruited patients, 28 data sets were analysed. Eleven underwent mechanochemical abaltion and 17 underwent radiofrequency abaltion. There were no neurological complications. In total, 39% (11/28) of patients had grade 1 or 2 microbubbles detected. Thirty-six percent (4/11) of mechanochemical abaltion patients and 29% (5/17) of radiofrequency ablation patients had microbubbles with no significant difference between the groups ( p=0.8065). Conclusion A comparable prevalence of microbubbles between mechanochemical abaltion and radiofrequency ablation both of which are lower than that previously reported for ultrasound-guided foam sclerotherapy suggests that mechanochemical abaltion may not confer the same risk of neurological events as ultrasound-guided foam sclerotherapy for treatment of varicose veins.

  1. Renal Denervation Using an Irrigated Catheter in Patients with Resistant Hypertension: A Promising Strategy?

    International Nuclear Information System (INIS)

    Armaganijan, Luciana; Staico, Rodolfo; Moraes, Aline; Abizaid, Alexandre; Moreira, Dalmo; Amodeo, Celso; Sousa, Márcio; Borelli, Flávio; Armaganijan, Dikran; Sousa, J. Eduardo; Sousa, Amanda

    2014-01-01

    Systemic hypertension is an important public health problem and a significant cause of cardiovascular mortality. Its high prevalence and the low rates of blood pressure control have resulted in the search for alternative therapeutic strategies. Percutaneous renal sympathetic denervation emerged as a perspective in the treatment of patients with resistant hypertension. To evaluate the feasibility and safety of renal denervation using an irrigated catheter. Ten patients with resistant hypertension underwent the procedure. The primary endpoint was safety, as assessed by periprocedural adverse events, renal function and renal vascular abnormalities at 6 months. The secondary endpoints were changes in blood pressure levels (office and ambulatory monitoring) and in the number of antihypertensive drugs at 6 months. The mean age was 47.3 (± 12) years, and 90% of patients were women. In the first case, renal artery dissection occurred as a result of trauma due to the long sheath; no further cases were observed after technical adjustments, thus showing an effect of the learning curve. No cases of thrombosis/renal infarction or death were reported. Elevation of serum creatinine levels was not observed during follow-up. At 6 months, one case of significant renal artery stenosis with no clinical consequences was diagnosed. Renal denervation reduced office blood pressure levels by 14.6/6.6 mmHg, on average (p = 0.4 both for systolic and diastolic blood pressure). Blood pressure levels on ambulatory monitoring decreased by 28/17.6 mmHg (p = 0.02 and p = 0.07 for systolic and diastolic blood pressure, respectively). A mean reduction of 2.1 antihypertensive drugs was observed. Renal denervation is feasible and safe in the treatment of resistant systemic arterial hypertension. Larger studies are required to confirm our findings

  2. Renal Denervation Using an Irrigated Catheter in Patients with Resistant Hypertension: A Promising Strategy?

    Energy Technology Data Exchange (ETDEWEB)

    Armaganijan, Luciana, E-mail: luciana-va@hotmail.com; Staico, Rodolfo; Moraes, Aline; Abizaid, Alexandre; Moreira, Dalmo; Amodeo, Celso; Sousa, Márcio; Borelli, Flávio; Armaganijan, Dikran; Sousa, J. Eduardo; Sousa, Amanda [Instituto Dante Pazzanese de Cardiologia, São Paulo, SP (Brazil)

    2014-04-15

    Systemic hypertension is an important public health problem and a significant cause of cardiovascular mortality. Its high prevalence and the low rates of blood pressure control have resulted in the search for alternative therapeutic strategies. Percutaneous renal sympathetic denervation emerged as a perspective in the treatment of patients with resistant hypertension. To evaluate the feasibility and safety of renal denervation using an irrigated catheter. Ten patients with resistant hypertension underwent the procedure. The primary endpoint was safety, as assessed by periprocedural adverse events, renal function and renal vascular abnormalities at 6 months. The secondary endpoints were changes in blood pressure levels (office and ambulatory monitoring) and in the number of antihypertensive drugs at 6 months. The mean age was 47.3 (± 12) years, and 90% of patients were women. In the first case, renal artery dissection occurred as a result of trauma due to the long sheath; no further cases were observed after technical adjustments, thus showing an effect of the learning curve. No cases of thrombosis/renal infarction or death were reported. Elevation of serum creatinine levels was not observed during follow-up. At 6 months, one case of significant renal artery stenosis with no clinical consequences was diagnosed. Renal denervation reduced office blood pressure levels by 14.6/6.6 mmHg, on average (p = 0.4 both for systolic and diastolic blood pressure). Blood pressure levels on ambulatory monitoring decreased by 28/17.6 mmHg (p = 0.02 and p = 0.07 for systolic and diastolic blood pressure, respectively). A mean reduction of 2.1 antihypertensive drugs was observed. Renal denervation is feasible and safe in the treatment of resistant systemic arterial hypertension. Larger studies are required to confirm our findings.

  3. Intracardiac echo-guided radiofrequency catheter ablation of atrial fibrillation in patients with atrial septal defect or patent foramen ovale repair: a feasibility, safety, and efficacy study.

    Science.gov (United States)

    Lakkireddy, Dhanunjaya; Rangisetty, Umamahesh; Prasad, Subramanya; Verma, Atul; Biria, Mazda; Berenbom, Loren; Pimentel, Rhea; Emert, Martin; Rosamond, Thomas; Fahmy, Tamer; Patel, Dimpi; Di Biase, Luigi; Schweikert, Robert; Burkhardt, David; Natale, Andrea

    2008-11-01

    Intracardiac Echo-Guided Radiofrequency Catheter. Patients with atrial septal defect (ASD) are at higher risk for atrial fibrillation (AF) even after repair. Transseptal access in these patients is perceived to be difficult. We describe the feasibility, safety, and efficacy of pulmonary vein antral isolation (PVAI) in these patients. We prospectively compared post-ASD/patent foramen ovale (PFO) repair patients (group I, n = 45) with age-gender-AF type matched controls (group II, n = 45). All the patients underwent PVAI through a double transseptal puncture with a roving circular mapping catheter technique guided by intracardiac echocardiography (ICE). The short-term (3 months) and long-term (12 month) failure rates were assessed. In group I, 23 (51%) had percutaneous closure devices and 22 (49%) had a surgical closure. There was no significant difference between group I and II in the baseline characteristics. Intracardiac echo-guided double transseptal access was obtained in 98% of patients in group I and in 100% of patients in group II. PVAI was performed in all patients, with right atrial flutter ablation in 7 patients in group I and in 4 patients in group II. Over a mean follow-up of 15 +/- 4 months, group I had higher short-term (18% vs 13%, P = 0.77) and long-term recurrence (24% vs 18%, P = 0.6) than group II. There was no significant difference in the perioperative complications between the two groups. Echocardiography at 3 months showed interatrial communication in 2 patients in group I and 1 patient in group II, which resolved at 12 months. Percutaneous AF ablation using double transseptal access is feasible, safe, and efficacious in patients with ASD and PFO repairs.

  4. Irrigation vs. natural evacuation of left colostomy: a comparative study of 340 patients.

    Science.gov (United States)

    Terranova, O; Sandei, F; Rebuffat, C; Maruotti, R; Bortolozzi, E

    1979-01-01

    A comparative study of two methods of managing left colostomy (irrigation and natural evacuation) was carried out on 340 patients who were examined and interviewed at the Stoma Rehabilitation Clinic of the Institute of Surgical Pathology of the University of Padua. Ninety-two per cent of patients who irrigated their colostomies gained fecal continence. No patient who irrigated his colostomy had any cutaneous problem, and this group had significantly better results in preventing leakage of gas and odors compared with those patients using natural evacuation. For most patients who irrigated, the ability to predict or control bowel movements overcame fears of "being dirty" and related psychological problems. These patients also had more normal social and working lives than did those patients not irrigating their colostomies. Only one patient in our series had a colonic perforation, and any chance of a repeat incident will probably disappear with the cone-shaped catheters now available. The authors conclude that in properly selected patients, irrigation is the method of choice for management of left colostomy.

  5. Radiofrequency Neurotomy

    Science.gov (United States)

    ... your specific symptoms. What you can expect Before radiofrequency neurotomy Let your doctor know if you take ... tobacco products the day of your procedure. During radiofrequency neurotomy Radiofrequency neurotomy is an outpatient procedure, so ...

  6. Successful catheter ablation of a left anterior accessory pathway from the non-coronary cusp of the aortic valve.

    Science.gov (United States)

    Laranjo, Sérgio; Oliveira, Mário; Trigo, Conceição

    2015-08-01

    Left anterior accessory pathways are considered to be rare findings. Catheter ablation of accessory pathways in this location remains a challenging target, and few reports about successful ablation of these accessory pathways are available. We describe our experience regarding a case of a manifest left anterior accessory pathway ablation using radiofrequency energy at the junction of the left coronary cusp with the non-coronary cusp.

  7. Malfunctioning and infected tunneled infusion catheters: over-the-wire catheter exchange versus catheter removal and replacement.

    Science.gov (United States)

    Guttmann, David M; Trerotola, Scott O; Clark, Timothy W; Dagli, Mandeep; Shlansky-Goldberg, Richard D; Itkin, Maxim; Soulen, Michael C; Mondschein, Jeffrey I; Stavropoulos, S William

    2011-05-01

    To compare the safety and effectiveness of over-the-wire catheter exchange (catheter-exchange) with catheter removal and replacement (removal-replacement) at a new site for infected or malfunctioning tunneled infusion catheters. Using a quality assurance database, 61 patients with tunneled infusion catheters placed during the period July 2001 to June 2009 were included in this study. Patients receiving hemodialysis catheters were excluded. Catheter-exchange was performed in 25 patients, and same-day removal-replacement was performed in 36 patients. Data collected included demographic information, indication for initial catheter placement and replacement, dwell time for the new catheter, and ultimate fate of the new device. Statistical comparisons between the two cohorts were analyzed using the Kaplan-Meier technique and Fisher exact test. Catheters exchanged over the wire remained functional without infection for a median of 102 days (range, 2-570 days), whereas catheters removed and replaced were functional for a median 238 days (range, 1-292 days, P = .12). After catheter replacement, there were 11 instances of subsequent infection in the catheter-exchange group and 7 instances in the removal-replacement cohort, accounting for infection rates of 4.4 and 2.3 per 1,000 catheter days (P = .049). Patients in the catheter-exchange group had 3.2 greater odds of infection compared with patients in the removal-replacement group. Five malfunction events occurred in each group, accounting for 2.0 and 1.7 malfunctions per 1,000 catheter days in the catheter-exchange and removal-replacement groups (P = .73). Catheter-exchange of tunneled infusion catheters results in a higher infection rate compared with removal-replacement at a new site. The rate of catheter malfunction is not significantly different between the two groups. Catheter-exchange is an alternative for patients with tunneled infusion catheters who have limited venous access, but this technique should not be

  8. Assessment of right liver graft perfusion effectiveness between one and two-catheter infusion methods.

    Science.gov (United States)

    Jung, Bo-Hyun; Hwang, Shin; Ha, Tae-Yong; Song, Gi-Won; Jung, Dong-Hwan; Kim, Ki-Hun; Ahn, Chul-Soo; Moon, Deok-Bog; Park, Gil-Chun; Kang, Sung-Hwa; Yoon, Young-In; Lee, Sung-Gyu

    2014-05-01

    Conventional graft perfusion method using one small-caliber catheter takes a relatively long time for right liver graft perfusion, thus some modification is needed. In this study, we intended to assess the effectiveness of right liver graft perfusion methods through comparison of different infusion catheters. The study consisted of two parts including one bench experiment to obtain data of hydraulic infusion and one clinical trial of 40 cases on graft perfusion with one- versus two-catheter infusion methods. These two graft infusion methods were compared in terms of the perfusion time and washing-out efficiency. At bench experiment, the infusion flow rate and infusion pressure were 3.3 ml/sec and 1.9 cmH20 in one blood transfusion catheter group, and 11.7 ml/sec and 3.1 cmH20 in single transurethral resection of prostate irrigation catheter group, and 6.6 ml/sec and 2.0 cmH20 in two blood transfusion catheters group, respectively. In clinical trial with 40 right liver grafts, two-catheter group had a shorter graft portal perfusion time for the first 2 L of histidine-tryptophan-ketoglutarate (HTK) solution than the conventional one-catheter group (375±25 seconds vs. 662±34 seconds; p=0.001) and a lower rate of incomplete blood washing-out after the initial 2 L portal perfusion (40% vs. 85%; p=0.03). The two-catheter infusion method appears to be more effective than the conventional one-catheter infusion method for right liver graft perfusion at the back table. Large size of right liver grafts seems to be its good indication.

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  10. Importance of anticoagulation and postablation silent cerebral lesions: Subanalyses of REVOLUTION and reMARQable studies.

    Science.gov (United States)

    Grimaldi, Massimo; Swarup, Vijay; DeVille, Brian; Sussman, Jonathan; Jaïs, Pierre; Gaita, Fiorenzo; Duytschaever, Mattias; Ng, G Andre; Daoud, Emile; Lakkireddy, Dhanunjaya Dj; Horton, Rodney; Wickliffe, Andrew; Ellis, Christopher; Geller, Laszlo

    2017-12-01

    Silent cerebral lesions (SCLs) are a potential complication of left atrial radiofrequency ablation (RFA) procedures for paroxysmal atrial fibrillation (PAF). We aimed to compare the incidence of SCLs in patients treated with irrigated RFA multielectrode catheters (nMARQ ® Catheter group) and irrigated focal RFA catheters (NAVISTAR ® THERMOCOOL ® Catheter; TC group) after PAF ablation from subpopulation neurological assessment (SNA) cohorts of the REVOLUTION and reMARQable studies. Data from SNA cohorts in the prospective, nonrandomized REVOLUTION study (March 2011-September 2013) and the prospective, randomized, controlled reMARQable study (October 2013-November 2015) were included. The incidence of SCLs was assessed pre- and postablation using magnetic resonance imaging. Neurological deficits were assessed using the National Institutes of Health Stroke Scale, modified Rankin Scale, and Montreal Cognitive Assessment. A total of 37 patients from REVOLUTION and 76 patients from reMARQable were included in the SNA cohort of each study. In the REVOLUTION SNA cohort, the incidence of SCLs was 21.1% (4/19) in the nMARQ ® Catheter group and 5.9% (1/17) in the TC group. Findings from REVOLUTION helped inform the reMARQable study protocol's stringent anticoagulation regimen. SCL incidence was subsequently reduced in both groups (nMARQ ® Catheter, 7.9%; TC, 3.3%). No permanent neurological deficits were observed. Adherence to a stringent anticoagulation regimen prior to and during ablation procedures appears to be an important factor in minimizing the risk of SCL. © 2017 Wiley Periodicals, Inc.

  11. Real-time circumferential mapping catheter tracking for motion compensation in atrial fibrillation ablation procedures

    Science.gov (United States)

    Brost, Alexander; Bourier, Felix; Wimmer, Andreas; Koch, Martin; Kiraly, Atilla; Liao, Rui; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) has been identified as a major cause of stroke. Radiofrequency catheter ablation has become an increasingly important treatment option, especially when drug therapy fails. Navigation under X-ray can be enhanced by using augmented fluoroscopy. It renders overlay images from pre-operative 3-D data sets which are then fused with X-ray images to provide more details about the underlying soft-tissue anatomy. Unfortunately, these fluoroscopic overlay images are compromised by respiratory and cardiac motion. Various methods to deal with motion have been proposed. To meet clinical demands, they have to be fast. Methods providing a processing frame rate of 3 frames-per-second (fps) are considered suitable for interventional electrophysiology catheter procedures if an acquisition frame rate of 2 fps is used. Unfortunately, when working at a processing rate of 3 fps, the delay until the actual motion compensated image can be displayed is about 300 ms. More recent algorithms can achieve frame rates of up to 20 fps, which reduces the lag to 50 ms. By using a novel approach involving a 3-D catheter model, catheter segmentation and a distance transform, we can speed up motion compensation to 25 fps which results in a display delay of only 40 ms on a standard workstation for medical applications. Our method uses a constrained 2-D/3-D registration to perform catheter tracking, and it obtained a 2-D tracking error of 0.61 mm.

  12. Urinary catheters

    Science.gov (United States)

    Catheter - urine; Foley catheter; Indwelling catheter; Suprapubic catheters ... stones Blood infections ( septicemia ) Blood in the urine (hematuria) Kidney damage (usually only with long-term, indwelling ...

  13. The biophysics of renal sympathetic denervation using radiofrequency energy.

    Science.gov (United States)

    Patel, Hitesh C; Dhillon, Paramdeep S; Mahfoud, Felix; Lindsay, Alistair C; Hayward, Carl; Ernst, Sabine; Lyon, Alexander R; Rosen, Stuart D; di Mario, Carlo

    2014-05-01

    Renal sympathetic denervation is currently performed in the treatment of resistant hypertension by interventionists who otherwise do not typically use radiofrequency (RF) energy ablation in their clinical practice. Adequate RF lesion formation is dependent upon good electrode-tissue contact, power delivery, electrode-tissue interface temperature, target-tissue impedance and the size of the catheter's active electrode. There is significant interplay between these variables and hence an appreciation of the biophysical determinants of RF lesion formation is required to provide effective and safe clinical care to our patients. In this review article, we summarize the biophysics of RF ablation and explain why and how complications of renal sympathetic denervation may occur and discuss methods to minimise them.

  14. Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: A systematic review and meta-analysis.

    Science.gov (United States)

    Lin, Hui; Chen, Yi-He; Hou, Jian-Wen; Lu, Zhao-Yang; Xiang, Yin; Li, Yi-Gang

    2017-09-01

    CF-sensing catheter emerged as a novel ablation technology and was increasingly used in clinical practice. Nonetheless, available evidence of efficacy and safety comparison between CF-guided RF catheter ablation and non-CF-guided ablation for treatment of AF was still lacking. Twenty-two eligible studies were included after systematic review through the MEDLINE, Google Scholar, the Cochrane Library and PubMed databases. AF/atrial tachycardia-free survival was markedly improved in CF-guided catheter ablation compared with non-CF-guided ablation at a median 12-month follow-up (RR: 1.12, 95% CI: 1.06-1.19, P = 0.000, fixed). Notably, CF-guided catheter ablation presented a robust survival benefit for treatment of paroxysmal AF (RR: 1.10, 95% CI: 1.03-1.18, P = 0.005, fixed), but not persistent AF (RR: 1.07, 95% CI: 0.89-1.28, P = 0.466, fixed). Moreover, procedure time (WMD: -23.87, 95% CI: -33.83 to -13.91, P = 0.000, random), fluoroscopy time (WMD: -7.78, 95% CI: -13.93 to -1.63, P = 0.013, random) and RF time (WMD: -3.98, 95% CI: -7.78 to -0.17, P = 0.040, random) were significantly reduced in CF-guided catheter ablation. The incidence of procedure-related complications did not differ between these two technologies (RR: 0.83, 95% CI: 0.59 to 1.16, P = 0.271, fixed). CF-guided RF catheter ablation was associated with a significant AF/atrial tachycardia-free survival benefit compared with non-CF-guided ablation in patients with paroxysmal AF rather than persistent AF. In addition, CF-guided ablation strategy also reduced the procedure time, fluoroscopy time, as well as RF time despite no distinct effect on the alleviation of procedure-related complications. © 2017 Wiley Periodicals, Inc.

  15. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  16. Ablação com radiofreqüência de extra-sístoles da via de saída do ventrículo direito Radiofrequency catheter ablation of premature ventricular contractions originating in the right ventricular outflow tract

    Directory of Open Access Journals (Sweden)

    Francisco C. C. Darrieux

    2007-03-01

    Full Text Available OBJETIVOS: Avaliar se a ablação com radiofreqüência é um procedimento eficiente para o tratamento das extra-sístoles da via de saída do ventrículo direito (EVSVD, e se resulta em melhora dos sintomas. MÉTODOS: Estudo prospectivo, com 30 pacientes consecutivos (idade média de 40±13 anos, 25 do sexo feminino, sem cardiopatia estrutural aparente, com EVSVD, muito freqüentes (densidade média de 1.263±593/h, sintomáticos por mais de 1 ano (média =74 meses e refratários aos fármacos antiarrítmicos (3±1,7, incluindo os beta-bloqueadores, que foram submetidos à ablação com radiofreqüência. RESULTADOS: Após o primeiro procedimento, houve 23 sucessos iniciais (76,6% e 7 iniciais insucessos (23,4%. Quatro pacientes tiveram recorrências, sendo que dois desses não se submeteram ao segundo procedimento. O segundo procedimento foi realizado em 9 pacientes (7 insucessos iniciais e 2 recorrências, e o sucesso ocorreu em 5 pacientes adicionais, sendo 1 caso por acesso epicárdico. A taxa de sucesso final foi de 80% (24/30, e nenhuma complicação maior ocorreu. Após um seguimento médio de 14±6 meses, no grupo de sucesso final houve uma redução de mais de 90% na densidade das extra-sístoles(24/24; pOBJECTIVES: To evaluate if radiofrequency catheter ablation is an effective procedure for the treatment of right ventricular outflow tract premature ventricular contractions (RVOT-PVC and ascertain if it results in an improvement of symptoms. METHODS: A prospective study with 30 consecutive patients (mean age 40 ± 13 years, 25 females, with no apparent structural cardiopathy, with very frequent (mean density of 1,263 ± 593/h RVOT-PVC, symptomatic for more than one year (mean = 74 months and resistant to antiarrhythmic drugs (3 ± 1.7, including beta-blockers, who underwent radiofrequency catheter ablation. RESULTS: After the first procedure, there were 23 initial successful cases (76.6% and 7 initial failures (23.4%. Four patients

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  18. Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra.

    Science.gov (United States)

    Vaidyanathan, Subramanian; Singh, Gurpreet; Hughes, Peter L; Soni, Bakul M

    2016-01-01

    A male tetraplegic patient attended accident and emergency with a blocked catheter; on removing the catheter, he passed bloody urine. After three unsuccessful attempts were made to insert a catheter by nursing staff, a junior doctor inserted a three-way Foley catheter with a 30-mL balloon but inflated the balloon with 10 mL of water to commence the bladder irrigation. The creatinine level was mostly 19 µmol/L (range: 0-135 µmol/L) but increased to 46 µmol/L on day 7. Computerized tomography urogram revealed that the bilateral hydronephrosis with hydroureter was extended down to urinary bladder, the bladder was distended, prostatic urethra was dilated and filled with urine, and although the balloon of Foley catheter was not seen in the bladder, the tip of the catheter was seen lying in the urethra. Following the re-catheterization, the creatinine level decreased to 21 µmol/L. A follow-up ultrasound scan revealed no evidence of hydronephrosis in both kidneys. Flexible cystoscopy revealed inflamed bladder mucosa, catheter reaction, and tiny stones. There was no bladder tumor. This case report concludes that the cause of bilateral hydronephrosis, hydroureter, and distended bladder was inadequate drainage of urinary bladder as the Foley balloon that was under-filled slipped into the urethra resulting in an obstruction to urine flow. Urethral catheterization in tetraplegic patients should be performed by senior, experienced staff in order to avoid trauma and incorrect positioning. Tetraplegic subjects with decreased muscle mass have low creatinine level. Increase in creatinine level (>1.5 times the basal level) indicates acute kidney injury, although peak creatinine level may still be within laboratory reference range. While scanning the urinary tract of spinal cord injury patients with indwelling urinary catheter, if Foley balloon is not seen within the bladder, urethra should be scanned to locate the Foley balloon.

  19. Urinary catheter - infants

    Science.gov (United States)

    Bladder catheter - infants; Foley catheter - infants; Urinary catheter - neonatal ... A urinary catheter is a small, soft tube placed in the bladder. This article addresses urinary catheters in babies. WHY IS ...

  20. Randomised clinical trial of cryoballoon versus irrigated radio frequency catheter ablation for atrial fibrillation-the effect of double short versus standard exposure cryoablation duration during pulmonary vein isolation (CIRCA-DOSE): methods and rationale.

    Science.gov (United States)

    Andrade, Jason G; Deyell, Marc W; Badra, Mariano; Champagne, Jean; Dubuc, Marc; Leong-Sit, Peter; Macle, Laurent; Novak, Paul; Roux, Jean-Francois; Sapp, John; Tang, Anthony; Verma, Atul; Wells, George A; Khairy, Paul

    2017-10-05

    Pulmonary vein isolation (PVI) is an effective therapy for paroxysmal atrial fibrillation (AF), but it has limitations. The two most significant recent advances have centred on the integration of real-time quantitative assessment of catheter contact force into focal radio frequency (RF) ablation catheters and the development of dedicated ablation tools capable of achieving PVI with a single ablation lesion (Arctic Front cryoballoon, Medtronic, Minneapolis, MN, USA). Although each of these holds promise for improving the clinical success of catheter ablation of AF, there has not been a rigorous comparison of these advanced ablation technologies. Moreover, the optimal duration of cryoablation (freezing time) has not been determined. Patients undergoing an initial PVI procedure for paroxysmal AF will be recruited. Patients will be randomised 1:1:1 between contact-force irrigated RF ablation, short duration cryoballoon ablation (2 min applications) and standard duration cryoballoon ablation (4 min applications). The primary outcome is time to first documented AF recurrence on implantable loop recorder. With a sample size of 111 per group and a two-sided 0.025 significance level (to account for the two main comparisons), the study will have 80% power (using a log-rank test) to detect a difference of 20% between contact force RF catheter ablation and either of the two cryoballoon ablation groups. Factoring in a 4% loss to follow-up, 116 patients per group should be randomised and followed for a year (total study population of 348). The study was approved by the University of British Columbia Office of Research (Services) Ethics Clinical Research Ethics Board. Results of the study will be submitted for publication in a peer-reviewed journal. NCT01913522; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. HRV changes before and after radiofrequency ablation in patients with different origin of right ventricular outflow tract ventricular premature contraction

    Directory of Open Access Journals (Sweden)

    Yi-Ming Ma

    2017-04-01

    Full Text Available Objective: To observe the HRV changes before and after the radiofrequency current catheter ablationventricular premature beats originated from different site of right ventricular outflow tract. Methods: A total of 102 patients with frequent RVOT-VPC admitted to our hospital were accepted radiofrequency current catheter ablation (RF. According to the origin of RVOT-VPC, it was divided into 2 groups, one is from ventricular septum, and the other one is from free wall, and in each group, male and female are observed separately. Results: (1 HRV before RF ablation: 1 rMSSD in the female patients with RVOT-VPC from free wall was significantly lower than those from septum; 2 frequency domain index (W, LF were higher than normal range, and in male patients, LF/HF1. (2 HRV after RF ablation: 1 Significant changes were found in female patients with RVOT-VPC from septum, rMSSD, PNN50, HF and LF decreased; 2 In female patients with RVOT-VPC from free wall, rMSSD decreased; 3 In male patients, there were no significant HRV changes found before and after RF ablation. (3 Heart rate changes: 1 In female patients with RVOT-VPC from septum, heart rate decreased significantly [(76.47±9.47 bpm vs (69.29±14.59 bpm]. 2 No significant changes were found in male patients. Conclusion: In patients with RVOT-PVC sympathetic and vagus excitability increased, and after catheter ablation, in female patients with RVOT-PVC originated from septum, the HRV index relating to sympathetic and vagus excitability significantly decreased.

  2. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  3. LONG-TERM EFFICACY AND HEALTH STATUS IN PATIENTS WITH ATRIAL FIBRILLATION AFTER RADIOFREQUENCY ENDOCARDIAL CATHETER ABLATION IN MAZE REGIMEN

    Directory of Open Access Journals (Sweden)

    M. E. Protasov

    2015-01-01

    Full Text Available Aim: To evaluate efficacy of endocardial radiofrequency catheter ablation (RFA in atrial fibrillation (AF in Maze regimen, to assess patients’ health status with a European Quality of Life Questionnaire (EQ-5D and cardiovascular mortality in patients after the intervention taking anticoagulants.Materials and methods: 391 patients with AF (247 of them males aged from 18 to 77 years (mean age 54.9 ± 10.1 years were examined and got treatment. All patients underwent RFA, including pulmonary vein isolation, linear ablations of the posterior wall, left atrial roof and mitral isthmus. Their health status was assessed according to efficacy of the intervention and data from EQ-5D questionnaires.Results: At 3 and 36 months after the intervention, RFA efficacy in patients with paroxysmal AF was 92% and 83.3%, respectively, and in patients with persistent AF, 89.7% and 72.4%. According to EQ-5D “thermometer”, after 36 months patients with successful catheter ablation assessed their health status as being approximately at the same level as during initial hospitalization, i.e., in patients with paroxysmal AF this scale scored at 79.74% and 81.4%, and in patients with persistent AF, at 79.94% and 81.06%, respectively. However, if the endocardial Maze procedure was unsuccessful, there was a deterioration of health status from 80.8% to 70.14% in patients with paroxysmal AF and from 77.82% to 69.46% in those with persistent AF. The same trend was observed in the analysis of other EQ-5D items. All-cause cardiovascular mortality in the subgroup with successful RFA was lower than in the subgroup with unsuccessful RFA, irrespective of AF form (p < 0.001. A 36-month mortality rate in patients with paroxysmal AF after a successful RFA was 2.1% and in patients with persistent AF, 1.2%, after unsuccessful RFA the corresponding values being 13.4% and 9.6%. Causes of death in patients with successful and unsuccessful RFA were different. After successful RFA for

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  7. Predictors of Sick Sinus Syndrome in Patients after Successful Radiofrequency Catheter Ablation of Atrial Flutter

    OpenAIRE

    Song, Changho; Jin, Moo-Nyun; Lee, Jung-Hee; Kim, In-Soo; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Joung, Boyoung

    2014-01-01

    Purpose The identification of sick sinus syndrome (SSS) in patients with atrial flutter (AFL) is difficult before the termination of AFL. This study investigated the patient characteristics used in predicting a high risk of SSS after AFL ablation. Materials and Methods Out of 339 consecutive patients who had undergone radiofrequency ablation for AFL from 1991 to 2012, 27 (8%) had SSS (SSS group). We compared the clinical characteristics of patients with and without SSS (n=312, no-SSS group). ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  9. A simplified technique for a totally diverting transverse loop colostomy and distal irrigation.

    Science.gov (United States)

    Rose, D; Koniges, F; Frazier, T G

    1985-12-01

    This technique of totally diverting loop colostomy may be performed as an independent procedure or with exploratory laparotomy and surgical treatment on the distal part of the colon. Either a transverse or sigmoid loop colostomy can be used for diversion without the risk of fecal contamination of the peritoneal cavity, particularly when working with unprepared intestine. When distal irrigation is desired to purge the intestine of fecal material, either intraoperatively or as part of a subsequent intestinal preparation, it can easily be accomplished by placing an irrigating catheter distal to the staple line. In addition, the use of a small rubber suspension bar facilitates application of standard colostomy appliances for the stoma.

  10. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    Science.gov (United States)

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  11. Orthogonal electrode catheter array for mapping of endocardial focal site of ventricular activation

    Energy Technology Data Exchange (ETDEWEB)

    Desai, J.M.; Nyo, H.; Vera, Z.; Seibert, J.A.; Vogelsang, P.J. (Division of Cardiovascular Medicine, University of California, School of Medicine, Davis (USA))

    1991-04-01

    Precise location of the endocardial site of origin of ventricular tachycardia may facilitate surgical and catheter ablation of this arrhythmia. The endocardial catheter mapping technique can locate the site of ventricular tachycardia within 4-8 cm2 of the earliest site recorded by the catheter. This report describes an orthogonal electrode catheter array (OECA) for mapping and radiofrequency ablation (RFA) of endocardial focal site of origin of a plunge electrode paced model of ventricular activation in dogs. The OECA is an 8 F five pole catheter with four peripheral electrodes and one central electrode (total surface area 0.8 cm{sup 2}). In eight mongrel dogs, mapping was performed by arbitrarily dividing the left ventricle (LV) into four segments. Each segment was mapped with OECA to find the earliest segment. Bipolar and unipolar electrograms were obtained. The plunge electrode (not visible on fluoroscopy) site was identified by the earliest wave front arrival times of -30 msec or earlier at two or more electrodes (unipolar electrograms) with reference to the earliest recorded surface ECG (I, AVF, and V1). Validation of the proximity of the five electrodes of the OECA to the plunge electrode was performed by digital radiography and RFA. Pathological examination was performed to document the proximity of the OECA to the plunge electrode and also for the width, depth, and microscopic changes of the ablation. To find the segment with the earliest LV activation a total of 10 {plus minus} 3 (mean {plus minus} SD) positions were mapped. Mean arrival times at the two earlier electrodes were -39 {plus minus} 4 msec and -35 {plus minus} 3 msec. Digital radiography showed the plunge electrode to be within the area covered by all five electrodes in all eight dogs. The plunge electrode was within 1 cm2 area of the region of RFA in all eight dogs.

  12. Characterisation of three-dimensional mapping in Wolff-Parkinson-White syndrome with septal aneurysmal dyskinesis.

    Science.gov (United States)

    Okada, Seigo; Muneuchi, Jun; Origuchi, Hideki

    2018-01-01

    A 21-year-old man with Wolff-Parkinson-White syndrome and aneurysmal septal dyskinesis underwent radiofrequency catheter ablation of the accessory pathways. Before radiofrequency catheter ablation, the activation wavefront arose from the aneurysmal septum, whereas the propagation of the left ventricle was normalised after radiofrequency catheter ablation. These findings demonstrate the importance of the electro-mechanical interaction in patients with Wolff-Parkinson-White syndrome and ventricular dysfunction.

  13. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    Science.gov (United States)

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... lessen your anxiety during the procedure. The area of the groin or arm where the catheter will be inserted is shaved, ... contrast material is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is ...

  15. Hybrid laparoscopic and robotic ultrasound-guided radiofrequency ablation-assisted clampless partial nephrectomy.

    Science.gov (United States)

    Nadler, Robert B; Perry, Kent T; Smith, Norm D

    2009-07-01

    To describe a clampless approach made possible by creating an avascular plane of tissue with radiofrequency ablation. Laparoscopic partial nephrectomy is slowly gaining acceptance as a method to treat small (generator. Typically, we used a power setting of 50 W but have found settings as low as 25 W necessary to provide hemostasis for larger vessels. The tumor was then sharply excised with a negative margin using robotic scissors and electrocautery to facilitate tissue cutting. Retrograde injection of methylthioninium chloride and saline through an externalized ureteral catheter allowed for precise sutured closure of the collecting system. FloSeal and BioGlue were then applied, making surgical bolsters or parenchymal sutures unnecessary. Intraoperative histologic evaluation of the surgical margin and repeat resection of the tumor bed was possible because the renal hilum was not clamped, and no warm ischemia was used. This technique, which combines the improving technologies of robotic surgery, intraoperative laparoscopic ultrasonography, and radiofrequency ablation, might make more surgeons comfortable with the intricacies of laparoscopic suturing and eliminate prolonged warm ischemia times. Overall, this method should result in more patients being able to undergo minimally invasive laparoscopic partial nephrectomy.

  16. Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes

    Directory of Open Access Journals (Sweden)

    McVeigh Elliot R

    2009-08-01

    Full Text Available Abstract Background Catheter visualization and tracking remains a challenge in interventional MR. Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. Results The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability and antenna (signal attenuation properties. With this configuration, the temperature increase remained less than 2°C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. Conclusion We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures.

  17. Experimental animal study of a novel radiofrequency endovascular occlusion device.

    Science.gov (United States)

    Zacharoulis, Dimitris; Lazoura, Olga; Rountas, Christos; Katsimboulas, Michael; Mantzianas, George; Tzovaras, George; Habib, Nagy

    2011-07-01

    The purpose of this study was to present a radiofrequency (RF) endovascular occlusion device (ie, Habib VesCoag Catheter; EMcision Ltd, London, UK) and to evaluate safety and efficacy of the device for complete occlusion of normal porcine vessels. The study included 20 pigs. In each pig, a segmental branch of the right hepatic artery, a branch of the splenic artery, and a branch of one of the renal arteries were catheterized. A single or multiple applications of RF energy were performed until vessel occlusion was achieved. Fifteen days later, angiography was repeated to assess vessel patency. The vessels were then excised for pathological analysis. Vessels 2.5 to 6 mm in diameter were treated. Complete occlusion with a single attempt was achieved using a mean amount of energy of 110.67 J in vessels 2.5 to 3 mm, 111.67 J in vessels 3.5 to 4 mm, and 116.63 J in vessels 5 to 6 mm in diameter and was confirmed by angiography at the 15-day follow-up. Vascular occlusion can be effectively and safely achieved by endovascular application of RF energy to normal porcine arteries using the Habib VesCoag catheter. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

    Science.gov (United States)

    Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F

    2010-03-01

    Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete loss of pace capture directly along the circumferential

  19. PR Interval Associated Genes, Atrial Remodeling and Rhythm Outcome of Catheter Ablation of Atrial Fibrillation—A Gene-Based Analysis of GWAS Data

    Directory of Open Access Journals (Sweden)

    Daniela Husser

    2017-12-01

    Full Text Available Background: PR interval prolongation has recently been shown to associate with advanced left atrial remodeling and atrial fibrillation (AF recurrence after catheter ablation. While different genome-wide association studies (GWAS have implicated 13 loci to associate with the PR interval as an AF endophenotype their subsequent associations with AF remodeling and response to catheter ablation are unknown. Here, we perform a gene-based analysis of GWAS data to test the hypothesis that PR interval candidate genes also associate with left atrial remodeling and arrhythmia recurrence following AF catheter ablation.Methods and Results: Samples from 660 patients with paroxysmal (n = 370 or persistent AF (n = 290 undergoing AF catheter ablation were genotyped for ~1,000,000 SNPs. Gene-based association was investigated using VEGAS (versatile gene-based association study. Among the 13 candidate genes, SLC8A1, MEIS1, ITGA9, SCN5A, and SOX5 associated with the PR interval. Of those, ITGA9 and SOX5 were significantly associated with left atrial low voltage areas and left atrial diameter and subsequently with AF recurrence after radiofrequency catheter ablation.Conclusion: This study suggests contributions of ITGA9 and SOX5 to AF remodeling expressed as PR interval prolongation, low voltage areas and left atrial dilatation and subsequently to response to catheter ablation. Future and larger studies are necessary to replicate and apply these findings with the aim of designing AF pathophysiology-based multi-locus risk scores.

  20. Indwelling catheter care

    Science.gov (United States)

    Foley catheter ... You will need to make sure your indwelling catheter is working properly. You will also need to ... not get an infection or skin irritation. Make catheter and skin care part of your daily routine. ...

  1. WORKSHOPS: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991

  2. WORKSHOPS: Radiofrequency superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1992-01-15

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991.

  3. The impact of left ventricular deformation and dyssynchrony on improvement of left ventricular ejection fraction following radiofrequency catheter ablation in Wolff-Parkinson-White syndrome: A comprehensive study by speckle tracking echocardiography.

    Science.gov (United States)

    Nagai, Tomoo; Hamabe, Akira; Arakawa, Junko; Tabata, Hirotsugu; Nishioka, Toshihiko

    2017-11-01

    The purpose of this study was to evaluate left ventricular (LV) deformation and LV dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome and to identify the factors that affect the efficacy of radiofrequency catheter ablation (RFCA). Thirty patients (26 men, mean age 40 ± 12 years) with WPW syndrome were prospectively recruited for this study. They underwent 2-dimensional transthoracic echocardiography with speckle tracking analysis before RFCA and again within 48 hours after RFCA. Control group consisted of 15 age and sex-matched healthy volunteers. The patients had significantly lower LV ejection fraction (LVEF), global longitudinal strain (S l ), and global circumferential strain (S c ) compared with healthy controls (64% ± 8% vs 68% ± 5%, P = .049; -17.6% ± 3.2% vs -19.9% ± 3.3%, P = .037, -15.2% ± 2.5% vs -19.4% ± 2.5%, P syndrome, impaired LV circumferential deformation can be restored by RFCA with concomitant improvement in LV dyssynchrony and LVEF. © 2017, Wiley Periodicals, Inc.

  4. Radiofrequency Ablation of Lung Tumors

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Radiofrequency Ablation (RFA) / Microwave Ablation (MWA) of Lung Tumors ... and Microwave Ablation of Lung Tumors? What are Radiofrequency and Microwave Ablation of Lung Tumors? Radiofrequency ablation, ...

  5. N-butyl cyanoacrylate embolization with blood flow control of an arterioportal shunt that developed after radiofrequency ablation of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sonomura, Tetsuo; Kawai, Nobuyuki; Kishi, Kazushi [Wakayama Medical University, Wakayama (Japan); and others

    2014-04-15

    We present a case of a patient with rapid deterioration of esophageal varices caused by portal hypertension accompanied by a large arterioportal shunt that developed after radiofrequency ablation of hepatocellular carcinoma. We used n-butyl cyanoacrylate (NBCA) as an embolic material to achieve pinpoint embolization of the shunt, because the microcatheter tip was 2 cm away from the shunt site. Under hepatic arterial flow control using a balloon catheter, the arterioportal shunt was successfully embolized with NBCA, which caused an improvement in the esophageal varices.

  6. Image-guided radiofrequency ablation (RFA) of spinal tumors

    International Nuclear Information System (INIS)

    Gevargez, Athour; Groenemeyer, Dietrich H.W.

    2008-01-01

    Purpose: To evaluate retrospectively the efficacy and safety of radiofrequency ablation (RFA) in patients with spinal tumors. Materials and methods: Forty-one patients (25 men, 16 women; age range, 46-82 years) with nonresectable primary or secondary tumor involvement of the spine unresponsive to chemo- and radiotherapy received RFA treatment. Two radiofrequency ablation systems, one with a cool-tip electrode and one with an expandable electrode catheter, were used. Both systems work impedance controlled with a power output of 150- 200 W. Each coagulation cycle lasted 12-15 min depending on tumor impedance. Several single RFA cycles of 15 min each were used for overlapping RFAs in tumors with diameters of more than 3 cm. Temperature was kept between 50 deg. C and 120 deg. C and was chosen according to spinal cord distance and patient heat tolerance during the ablation. Multi-slice computed tomography (CT) combined with C-arm fluoroscopy guided the intervention. Efficacy outcomes were assessed after about 6 weeks, 6 months, and more than 6 months using standardized questionnaires and indices regarding tumor pain, pain disability, functional activities, quality of life, neurological status, and tumor progression. Results: RFA significantly reduced tumor-induced pain within 6 weeks, improved daily activities, and maintained quality of life. Mean time to tumor progression was 730 ± 54 days (Kaplan-Meier estimate). No RFA-associated complications were reported. Conclusion: RFA of primary and secondary spinal tumors, which were unresponsive to chemo- and radiotherapy and prone to progression, is a safe, resource-saving, and highly effective percutaneous technique in patients with nonresectable spinal tumors

  7. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters

    International Nuclear Information System (INIS)

    Adam, G.; Glowinski, A.; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-01-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212[). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF[). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [de

  8. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  9. Radiofrequency ablation of osteoid osteoma

    NARCIS (Netherlands)

    Vanderschueren, Geert Maria Joris Michael

    2009-01-01

    The main purpose of this thesis was to evaluate the effectiveness and safety of CT-guided radiofrequency ablation for the treatment of spinal and non-spinal osteoid osteomas. Furthermore, the technical requirements needed for safe radiofrequency ablation and the clinical outcome after radiofrequency

  10. Transurethral radiofrequency collagen denaturation for the treatment of women with urinary incontinence.

    Science.gov (United States)

    Kang, Diana; Han, Julia; Neuberger, Molly M; Moy, M Louis; Wallace, Sheila A; Alonso-Coello, Pablo; Dahm, Philipp

    2015-03-18

    evidence using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach. We included in the analysis one small sham-controlled randomised trial of 173 women performed in the United States. Participants enrolled in this study had been diagnosed with stress UI and were randomly assigned to transurethral radiofrequency collagen denaturation (treatment) or a sham surgery using a non-functioning catheter (no treatment). Mean age of participants in the 12-month multi-centre trial was 50 years (range 22 to 76 years).Of three patient-important primary outcomes selected for this systematic review, the number of women reporting UI symptoms after intervention was not reported. No serious adverse events were reported for the transurethral radiofrequency collagen denaturation arm or the sham treatment arm during the 12-month trial. Owing to high risk of bias and imprecision, we downgraded the quality of evidence for this outcome to low. The effect of transurethral radiofrequency collagen denaturation on the number of women with an incontinence quality of life (I-QOL) score improvement ≥ 10 points at 12 months was as follows: RR 1.11, 95% CI 0.77 to 1.62; participants = 142, but the confidence interval was wide. For this outcome, the quality of evidence was also low as the result of high risk of bias and imprecision.We found no evidence on the number of women undergoing repeat continence surgery. The risk of other adverse events (pain/dysuria (RR 5.73, 95% CI 0.75 to 43.70; participants = 173); new detrusor overactivity (RR 1.36, 95% CI 0.63 to 2.93; participants = 173); and urinary tract infection (RR 0.95, 95% CI 0.24 to 3.86; participants = 173) could not be established reliably as the trial was small. Evidence was insufficient for assessment of whether use of transurethral radiofrequency collagen denaturation was associated with an increased rate of urinary retention, haematuria and hesitancy compared with sham treatment in 173 participants. The GRADE

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... incision in the skin. Once the catheter is guided to the area being examined, a contrast material ... inserted into an artery. The catheter is then guided through the arteries to the area to be ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... catheter , is inserted into an artery through a small incision in the skin. Once the catheter is ... the tube and images are captured using a small dose of ionizing radiation ( x-rays ). top of ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... it will make the rest of the procedure pain-free. You will not feel the catheter in ... nurse if you notice any bleeding, swelling or pain at the site where the catheter entered the ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... should inform the nurse if you notice any bleeding, swelling or pain at the site where the ... Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter tip ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... or other procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the ... days. Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  1. Catheter-related bloodstream infection.

    Science.gov (United States)

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  4. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    Science.gov (United States)

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  5. The comparison of interventional tubal recanalization and drug irrigation recanalization in the management of oviduct obstruction

    International Nuclear Information System (INIS)

    Zhang Xiaomin; Li Yuzhi

    2002-01-01

    Objective: To explore and compare the efficacy of the interventional and drags irrigation tube recanalization for infertile women with fallopian tube obstruction. Methods: Eighteen patients with 36 tubal obstructions in the research group were treated with interventional tube recanalization and drugs infusion into tube through catheter. Other 10 cases with 20 tubal obstructions in the comparison group were treated only with drugs irrigation. All cases received followed up examination in 6 mouths. Results: The successful rates of recanalization were 61.1% (22/36) in the research group and 30.0% (6/20) in the comparison group, respectively. There was significant difference between the two groups (P < 0.05). The recurrence was 4 tube in the research group, 1 tube in the comparison group six months. Conclusion: The interventional tubal recanalization is a simple, sate and more effective treatment method of choice compared with the tubal recanalization with the traditional drag irrigation for fallopian tube obstruction

  6. Clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of catheter-related bloodstream infections in neonatology: A systematic review.

    Science.gov (United States)

    Ferreira, Janita; Camargos, Paulo Augusto Moreira; Clemente, Wanessa Trindade; Romanelli, Roberta Maia de Castro

    2018-01-01

    Neonatal sepsis is the most frequent health care-associated infection in neonatal units. This study aimed to analyze articles on the clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of intravascular catheter-related bloodstream infection (CRBSI) in neonates. A systematic search was performed for studies published from 1987-2017, without language restriction. Observational studies carried out in neonates with CRBSI diagnosed using catheter-drawn blood samples or catheter tip cultures were included. A total of 412 articles were identified in the databases and 10 articles were included. The 7 studies that evaluated central venous catheter tip cultures and cultures of catheter fragments presented sensitivities ranging from 58.5%-100% and specificities ranging from 60%-95.7%. Three studies that evaluated catheter-drawn blood cultures, paired with peripheral blood cultures, reported sensitivity and specificity of 94% and 71% when evaluated for the differential time to positivity. When quantitative evaluation was performed, the sensitivity and specificity were 80% and 99.4%. Most of the studies analyzed cultures from the central venous catheter tip and catheter fragments for the diagnosis of CRBSI in neonatal populations. The results of this review suggest that the analysis of the catheter-drawn blood samples and catheter tip cultures, paired with peripheral blood cultures, are efficient methods for the diagnosis of CRBSI in neonates. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is removed and the incision site is closed by applying pressure on the area for approximately 10 to 20 ...

  9. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  10. Comparison of branch and distally focused main renal artery denervation using two different radio-frequency systems in a porcine model.

    Science.gov (United States)

    Mahfoud, Felix; Pipenhagen, Catherine A; Boyce Moon, L; Ewen, Sebastian; Kulenthiran, Saarraaken; Fish, Jeffrey M; Jensen, James A; Virmani, Renu; Joner, Michael; Yahagi, Kazuyuki; Tsioufis, Costas; Böhm, Michael

    2017-08-15

    Anatomic placement of lesions may impact efficacy of radio-frequency (RF) catheter renal denervation (RDN). However, it is unclear if it is necessary to perform treatments post bifurcation with systems that may provide deeper penetration to achieve successful RDN. Sixteen domestic swine (n=16) were randomly assigned to 4 groups: 1) 8 lesions created in the branch arteries using the Spyral catheter (SP8); 2) 8 lesions created in the branch arteries plus 4 lesions created in the main artery using the SP catheter (SP12); 3) 8 lesions created in the main artery using the EnligHTN catheter with the distal position as close as possible to the bifurcation (EN8); and 4) 12 lesions created in the main artery using the EN catheter with the distal position as close as possible to the bifurcation (EN12). Each arm showed statistically significant changes in kidney norepinephrine (NE, ng/g) between treated kidneys vs. untreated contralateral control. There were no statistically significant differences in tissue NE% reductions across each arm based on catheter, anatomic location, & number of lesions (p=0.563): EN8 -74±34%, EN12 -95±3%, SP8 -76±16%, SP12 -82±17% (p=0.496). A total of 46 lesions were measured for lesion depth: EN main (3.3±2.8mm) vs. SP branch (2.0±1.0mm, p=0.039), SP main (2.9±1.6mm) vs. SP branch (p=0.052), and EN main vs. SP main (p=0.337). Distally-focused main renal artery treatment using the EN system appears to be equally efficacious in reducing tissue NE levels compared with SP treatment in the branches plus main renal arteries, advocating for device-specific procedure execution. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Percutaneous Intraductal Radiofrequency Ablation is a Safe Treatment for Malignant Biliary Obstruction: Feasibility and Early Results

    Energy Technology Data Exchange (ETDEWEB)

    Mizandari, Malkhaz [Tbilisi State Medical University, Department of Radiology (Georgia); Pai, Madhava, E-mail: madhava.pai@imperial.ac.uk; Xi Feng [Imperial College, London, Hammersmith Hospital Campus, Department of Surgery (United Kingdom); Valek, Vlastimil; Tomas, Andrasina [University Hospital Brno Bohunice, Department of Radiology (Czech Republic); Quaretti, Pietro [IRCCS Policlinico San Matteo, Department of Radiology (Italy); Golfieri, Rita; Mosconi, Cristina [University of Bologna, Department of Radiology, Policlinico S. Orsola-Malpighi (Italy); Ao Guokun [The 309 Hospital of Chinese PLA, Department of Radiology (China); Kyriakides, Charis [Imperial College, London, Hammersmith Hospital Campus, Department of Surgery (United Kingdom); Dickinson, Robert [Imperial College London, Department of Bioengineering (United Kingdom); Nicholls, Joanna; Habib, Nagy, E-mail: nagy.habib@imperial.ac.uk [Imperial College, London, Hammersmith Hospital Campus, Department of Surgery (United Kingdom)

    2013-06-15

    Purpose. Previous clinical studies have shown the safety and efficacy of this novel radiofrequency ablation catheter when used for endoscopic palliative procedures. We report a retrospective study with the results of first in man percutaneous intraductal radiofrequency ablation in patients with malignant biliary obstruction. Methods. Thirty-nine patients with inoperable malignant biliary obstruction were included. These patients underwent intraductal biliary radiofrequency ablation of their malignant biliary strictures following external biliary decompression with an internal-external biliary drainage. Following ablation, they had a metal stent inserted. Results. Following this intervention, there were no 30-day mortality, hemorrhage, bile duct perforation, bile leak, or pancreatitis. Of the 39 patients, 28 are alive and 10 patients are dead with a median survival of 89.5 (range 14-260) days and median stent patency of 84.5 (range 14-260) days. One patient was lost to follow-up. All but one patient had their stent patent at the time of last follow-up or death. One patient with stent blockage at 42 days postprocedure underwent percutaneous transhepatic drain insertion and restenting. Among the patients who are alive (n = 28) the median stent patency was 92 (range 14-260) days, whereas the patients who died (n = 10) had a median stent patency of 62.5 (range 38-210) days. Conclusions. In this group of patients, it appears that this new approach is feasible and safe. Efficacy remains to be proven in future, randomized, prospective studies.

  12. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  13. Catheter-based high-intensity ultrasound for epicardial ablation of the left ventricle: device design and in vivo feasiblity

    Science.gov (United States)

    Salgaonkar, Vasant A.; Nazer, Babak; Jones, Peter D.; Tanaka, Yasuaki; Martin, Alastair; Ng, Bennett; Duggirala, Srikant; Diederich, Chris J.; Gerstenfeld, Edward P.

    2015-03-01

    The development and in vivo testing of a high-intensity ultrasound thermal ablation catheter for epicardial ablation of the left ventricle (LV) is presented. Scar tissue can occur in the mid-myocardial and epicardial space in patients with nonischemic cardiomyopathy and lead to ventricular tachycardia. Current ablation technology uses radiofrequency energy, which is limited epicardially by the presence of coronary vessels, phrenic nerves, and fat. Ultrasound energy can be precisely directed to deliver targeted deep epicardial ablation while sparing intervening epicardial nerve and vessels. The proof-of-concept ultrasound applicators were designed for sub-xyphoid access to the pericardial space through a steerable 14-Fr sheath. The catheter consists of two rectangular planar transducers, for therapy (6.4 MHz) and imaging (5 MHz), mounted at the tip of a 3.5-mm flexible nylon catheter coupled and encapsulated within a custom-shaped balloon for cooling. Thermal lesions were created in the LV in a swine (n = 10) model in vivo. The ultrasound applicator was positioned fluoroscopically. Its orientation and contact with the LV were verified using A-mode imaging and a radio-opaque marker. Ablations employed 60-s exposures at 15 - 30 W (electrical power). Histology indicated thermal coagulation and ablative lesions penetrating 8 - 12 mm into the left ventricle on lateral and anterior walls and along the left anterior descending artery. The transducer design enabled successful sparing from the epicardial surface to 2 - 4 mm of intervening ventricle tissue and epicardial fat. The feasibility of targeted epicardial ablation with catheter-based ultrasound was demonstrated.

  14. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  15. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  16. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  17. The efficacy of noble metal alloy urinary catheters in reducing catheter-associated urinary tract infection

    Directory of Open Access Journals (Sweden)

    Alanood Ahmed Aljohi

    2016-01-01

    Results: A 90% relative risk reduction in the rate of CAUTI was observed with the noble metal alloy catheter compared to the standard catheter (10 vs. 1 cases, P = 0.006. When considering both catheter-associated asymptomatic bacteriuria and CAUTI, the relative risk reduction was 83% (12 vs. 2 cases, P = 0.005. In addition to CAUTI, the risk of acquiring secondary bacteremia was lower (100% for the patients using noble metal alloy catheters (3 cases in the standard group vs. 0 case in the noble metal alloy catheter group, P = 0.24. No adverse events related to any of the used catheters were recorded. Conclusion: Results from this study revealed that noble metal alloy catheters are safe to use and significantly reduce CAUTI rate in ICU patients after 3 days of use.

  18. 47 CFR 2.801 - Radiofrequency device defined.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...

  19. Button self-retaining drainage catheter

    International Nuclear Information System (INIS)

    Caridi, James G.; Hawkins, Irvin F.; Akins, E. William; Young, Ronald S.

    1997-01-01

    To help improve patient acceptance of long-term internal/external catheter access to the biliary tract in those with benign biliary obstruction, a simple design allows the catheter end to remain flush with the skin. It consists of a clothes button affixed to the drainage catheter with a wood screw after the catheter has been cut off at the skin exit. This button/screw device has been used successfully in 22 patients over the last 10 years; catheter exchanges were easily accomplished

  20. Safety of gentamicin bladder irrigations in complex urological cases.

    Science.gov (United States)

    Defoor, William; Ferguson, Denise; Mashni, Susan; Creelman, Lisa; Reeves, Deborah; Minevich, Eugene; Reddy, Pramod; Sheldon, Curtis

    2006-05-01

    Recurrent urinary tract infections are common in complex pediatric urological cases, particularly those requiring clean intermittent catheterization. At our institution gentamicin bladder irrigations have been used for antimicrobial prophylaxis and to treat symptomatic bacteriuria, particularly when the infection does not involve the upper urinary tract. The purpose of this study was to assess the safety of this therapy. A retrospective study was performed of all children treated with gentamicin bladder irrigations from 1999 to 2004. The dose was 14 mg gentamicin in 30 ml saline instilled via catheter once or twice daily. Serum creatinine and random gentamicin levels were obtained according to a protocol based on risk of gentamicin toxicity. Patient demographics, laboratory results and outcomes were abstracted from the medical records. A total of 80 patients (38 males and 42 females) were identified. Median patient age was 10 years and median duration of treatment was 90 days. No patient had detectable serum gentamicin levels greater than 0.4 mg/dl. Small increases in serum creatinine were seen in 3 patients, all of whom had chronic renal insufficiency. A total of 21 patients (26%) had breakthrough UTIs, of which 5 (24%) were gentamicin resistant. No adverse events were documented. Gentamicin bladder irrigations are a helpful adjunct in the management of complex pediatric urological cases involving recurrent symptomatic bacteriuria. We no longer require intensive laboratory monitoring of low risk patients at our institution.

  1. Risk of Ionizing Radiation in Women of Childbearing Age undergoing Radiofrequency Ablation

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Gustavo Glotz de, E-mail: gglima.pesquisa@gmail.com; Gomes, Daniel Garcia; Gensas, Caroline Saltz; Simão, Mariana Fernandez; Rios, Matheus N.; Pires, Leonardo Martins; Kruse, Marcelo Lapa; Leiria, Tiago Luiz Luz [Instituto de Cardiologia, Fundação Universitária de Cardiologia, Porto Alegre, RS (Brazil)

    2013-11-15

    The International Commission of Radiology recommends a pregnancy screening test to all female patients of childbearing age who will undergo a radiological study. Radiation is known to be teratogenic and its effect is cumulative. The teratogenic potential starts at doses close to those used during these procedures. The prevalence of positive pregnancy tests in patients undergoing electrophysiological studies and/or catheter ablation in our midst is unknown. To evaluate the prevalence of positive pregnancy tests in female patients referred for electrophysiological study and/or radiofrequency ablation. Cross-sectional study analyzing 2,966 patients undergoing electrophysiological study and/or catheter ablation, from June 1997 to February 2013, in the Institute of Cardiology of Rio Grande do Sul. A total of 1490 procedures were performed in women, of whom 769 were of childbearing age. All patients were screened with a pregnancy test on the day before the procedure. Three patients tested positive, and were therefore unable to undergo the procedure. The prevalence observed was 3.9 cases per 1,000 women of childbearing age. Because of their safety and low cost, pregnancy screening tests are indicated for all women of childbearing age undergoing radiological studies, since the degree of ionizing radiation needed for these procedures is very close to the threshold for teratogenicity, especially in the first trimester, when the signs of pregnancy are not evident.

  2. Risk of Ionizing Radiation in Women of Childbearing Age undergoing Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Lima, Gustavo Glotz de; Gomes, Daniel Garcia; Gensas, Caroline Saltz; Simão, Mariana Fernandez; Rios, Matheus N.; Pires, Leonardo Martins; Kruse, Marcelo Lapa; Leiria, Tiago Luiz Luz

    2013-01-01

    The International Commission of Radiology recommends a pregnancy screening test to all female patients of childbearing age who will undergo a radiological study. Radiation is known to be teratogenic and its effect is cumulative. The teratogenic potential starts at doses close to those used during these procedures. The prevalence of positive pregnancy tests in patients undergoing electrophysiological studies and/or catheter ablation in our midst is unknown. To evaluate the prevalence of positive pregnancy tests in female patients referred for electrophysiological study and/or radiofrequency ablation. Cross-sectional study analyzing 2,966 patients undergoing electrophysiological study and/or catheter ablation, from June 1997 to February 2013, in the Institute of Cardiology of Rio Grande do Sul. A total of 1490 procedures were performed in women, of whom 769 were of childbearing age. All patients were screened with a pregnancy test on the day before the procedure. Three patients tested positive, and were therefore unable to undergo the procedure. The prevalence observed was 3.9 cases per 1,000 women of childbearing age. Because of their safety and low cost, pregnancy screening tests are indicated for all women of childbearing age undergoing radiological studies, since the degree of ionizing radiation needed for these procedures is very close to the threshold for teratogenicity, especially in the first trimester, when the signs of pregnancy are not evident

  3. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    Science.gov (United States)

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  4. Predicting nurses' acceptance of radiofrequency identification technology.

    Science.gov (United States)

    Norten, Adam

    2012-10-01

    The technology of radiofrequency identification allows for the scanning of radiofrequency identification-tagged objects and individuals without line-of-sight requirements. Healthcare organizations use radiofrequency identification to ensure the health and safety of patients and medical personnel and to uncover inefficiencies. Although the successful implementation of a system incorporating radiofrequency identification technologies requires acceptance and use of the technology, some nurses using radiofrequency identification in hospitals feel like "Big Brother" is watching them. This predictive study used a theoretical model assessing the effect of five independent variables: privacy concerns, attitudes, subjective norms, controllability, and self-efficacy, on a dependent variable, nurses' behavioral intention to use radiofrequency identification. A Web-based questionnaire containing previously validated questions was answered by 106 US RNs. Multiple linear regression showed that all constructs together accounted for 60% of the variance in nurses' intention to use radiofrequency identification. Of the predictors in the model, attitudes provided the largest unique contribution when the other predictors in the model were held constant; subjective norms also provided a unique contribution. Privacy concerns, controllability, and self-efficacy did not provide a significant contribution to nurses' behavioral intention to use radiofrequency identification.

  5. Conventional Radiofrequency Thermocoagulation vs Pulsed Radiofrequency Neuromodulation of Ganglion Impar in Chronic Perineal Pain of Nononcological Origin.

    Science.gov (United States)

    Usmani, Hammad; Dureja, G P; Andleeb, Roshan; Tauheed, Nazia; Asif, Naiyer

    2018-01-10

    Chronic nononcological perineal pain has been effectively managed by ganglion Impar block. Chemical neurolysis, cryoablation, and radiofrequency ablation have been the accepted methods of blockade. Recently, pulsed radiofrequency, a novel variant of conventional radiofrequency, has been used for this purpose. This was a prospective, randomized, double-blind study. Two different interventional pain management centers in India. To compare the efficacy of conventional radiofrequency and pulsed radiofrequency for gangliom Impar block. The patients were randomly allocated to one of two groups. In the conventional radiofrequency (CRF) group (N = 34), conventional radiofrequency ablation was done, and in the PRF pulsed radiofrequency (PRF) group (N = 31), pulsed radiofrequency ablation was done. After informed and written consent, fluoroscopy-guided ganglion Impar block was performed through the first intracoccygeal approach. The extent of pain relief was assessed by visual analog scale (VAS) at 24 hours, and at the first, third, and sixth weeks following the intervention. A questionnaire to evaluate subjective patient satisfaction was also used at each follow-up visit. In the CRF group, the mean VAS score decreased significantly from the baseline value at each follow-up visit. But in the PRF group, this decrease was insignificant except at 24-hour follow-up. Intergroup comparison also showed significantly better pain relief in the CRF group as compared with the PRF group. At the end of follow-up, 28 patients (82%) in the CRF group and four patients (13%) in the PRF group had excellent results, as assessed by the subjective patient satisfaction questionnaire. There was no complication in any patient of either study group, except for short-lived infection at the site of skin puncture in a few. Ganglion Impar block by conventional radiofrequency provided a significantly better quality of pain relief with no major side effects in patients with chronic

  6. Radiofrequency ablation in dermatology

    Directory of Open Access Journals (Sweden)

    Sachdeva Silonie

    2007-01-01

    Full Text Available Radiofreqeuency ablation is a versatile dermatosurgical procedure used for surgical management of skin lesions by using various forms of alternating current at an ultra high frequency. The major modalities in radiofrequency are electrosection, electrocoagulation, electrodessication and fulguration. The use of radiofrequency ablation in dermatosurgical practice has gained importance in recent years as it can be used to treat most of the skin lesions with ease in less time with clean surgical field due to adequate hemostasis and with minimal side effects and complications. This article focuses on the major tissue effects and factors influencing radiofrequency ablation and its application for various dermatological conditions.

  7. Optimized Subsurface Irrigation System: The Future of Sugarcane Irrigation

    Directory of Open Access Journals (Sweden)

    M. H. J. P. Gunarathna

    2018-03-01

    Full Text Available Climate change may harm the growth and yield of sugarcane (Saccharum officinarum L. without the introduction of appropriate irrigation facilities. Therefore, new irrigation methods should be developed to maximize water use efficiency and reduce operational costs. OPSIS (optimized subsurface irrigation system is a new solar-powered automatic subsurface irrigation system that creates a phreatic zone below crop roots and relies on capillarity to supply water to the root zone. It is designed for upland crops such as sugarcane. We investigated the performance of OPSIS for irrigating sugarcane and evaluated its performance against sprinkler irrigation under subtropical conditions. We conducted field experiments in Okinawa, Japan, over the period from 2013 to 2016 and took measurements during spring- and summer-planted main crops and two ratoon crops of the spring-planted crop. Compared with sprinkler irrigation, OPSIS produced a significantly higher fresh cane yield, consumed less irrigation water and provided a higher irrigation water use efficiency. We conclude that OPSIS could be adopted as a sustainable solution to sugarcane irrigation in Okinawa and similar environments.

  8. Peritoneal catheter fixation combined with straight upward tunnel and low implant position to prevent catheter malfunction.

    Science.gov (United States)

    Zhang, Qingyan; Jiang, Chunming; Zhu, Wei; Sun, Cheng; Xia, Yangyang; Tang, Tianfeng; Wan, Cheng; Shao, Qiuyuan; Liu, Jing; Jin, Bo; Zhang, Miao

    2018-03-01

    Catheter malfunction is the main reason for early peritoneal dialysis (PD) technique failure. This study aimed to evaluate the effect of a new surgery technique with catheter fixation to the lower abdominal wall combined with straight upward tunnel and low implant position in reducing catheter malfunction. Patients with end stage renal disease who received PD in our centre from January 2013 to December 2015 were involved in this study. They were randomly divided into three groups according to surgical technique: traditional open surgery group, modified open surgery group and modified open surgery with catheter fixation group. All patients were followed up for six months after surgery. Catheter- related complications were analyzed. A total of 152 patients were involved. Among them, 49 received traditional open surgery (TOS group), 49 received modified open surgery (MOS group), and 54 received modified open surgery with catheter fixation (MOS-F group). During follow-up, no patients (0%) in MOS-F group developed catheter malfunction which was significantly lower than that of the TOS group (0 vs 16.33%, P = 0.002). Although not statistically significant, the incidence of catheter malfunction was lower in MOS-F group than that in MOS group (0 vs 4.08%, P = 0.134). No significant difference was observed in the episodes of infection, bleeding, leakage, inflow or outflow pain, hernia and delayed wound healing among the three groups (all P > 0.05). Catheter fixation combined with straight upward tunnel and low implant position can effectively prevent catheter malfunction in PD catheter placement. © 2016 Asian Pacific Society of Nephrology.

  9. CT-guided radiofrequency tumor ablation in children

    International Nuclear Information System (INIS)

    Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia

    2014-01-01

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  10. CT-guided radiofrequency tumor ablation in children

    Energy Technology Data Exchange (ETDEWEB)

    Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)

    2014-11-15

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  11. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    Science.gov (United States)

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  12. Epidural Catheter Breakage In-Situ

    Directory of Open Access Journals (Sweden)

    Geetanjali S Verma

    2014-09-01

    Full Text Available A 45yr old woman diagnosed with dysfunctional uterine bleeding and incisional hernia was planned for total abdominal hysterectomy with bilateral salpingo-oophorectomy and mesh repair under combined spinal and epidural anaesthesia. Using VYGON® epidural catheter with its recommended introducer, the catheter was inserted but it snapped off at 11cm mark while positioning the catheter. After radiological confirmation, the neurosurgeon removed the catheter under general anaesthesia, which was followed by the scheduled surgery.

  13. RADIOFREQUENCY SUPERCONDUCTIVITY: Workshop

    International Nuclear Information System (INIS)

    Lengeler, Herbert

    1989-01-01

    Superconducting radiofrequency is already playing an important role in the beam acceleration system for the TRISTAN electron-positron collider at the Japanese KEK Laboratory and new such systems are being prepared for other major machines. Thus the fourth Workshop on Radiofrequency Superconductivity, organized by KEK under the chairmanship of local specialist Yuzo Kojima and held just before the International Conference on High Energy Accelerators, had much progress to review and even more to look forward to

  14. 21 CFR 882.4400 - Radiofrequency lesion generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion generator. 882.4400 Section... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4400 Radiofrequency lesion generator. (a) Identification. A radiofrequency lesion generator is a device used to produce...

  15. Experimental, Pathologic, and Clinical Findings of Radiofrequency Catheter Ablation of Para-Hisian Region From the Right Ventricle in Dogs and Humans.

    Science.gov (United States)

    Xue, Yumei; Zhan, Xianzhang; Wu, Shulin; Wang, Hongyue; Liu, Yang; Liao, Zili; Deng, Hai; Duan, Xuejing; Zeng, Shaoying; Liang, Dongpo; Elvan, Arif; Fang, Xianhong; Liao, Hongtao; Ramdat Misier, Anand R; Smit, Jaap Jan J; Metzner, Andreas; Heeger, Christian-Hendrik; Liu, Fangzhou; Wang, Feng; Zhang, Zhiwei; Kuck, Karl-Heinz; Yen Ho, Siew; Ouyang, Feifan

    2017-06-01

    Ablation of para-Hisian accessory pathway (AP) poses high risks of atrioventricular block. We developed a pacing technique to differentiate the near-field (NF) from far-field His activations to avoid the complication. Three-dimensional mapping of the right ventricle was performed in 15 mongrel dogs and 23 patients with para-Hisian AP. Using different pacing outputs, the NF- and far-field His activation was identified on the ventricular aspect. Radiofrequency application was delivered at the NF His site in 8 (group 1) and the far-field His site in 7 dogs (group 2), followed by pathologic examination after 14 days. NF His activation was captured with 5 mA/1 ms in 10 and 10 mA/1 ms in 5 dogs. In group 1, radiofrequency delivery resulted in complete atrioventricular block in 3, right bundle branch block with HV (His-to-ventricular) interval prolongation in 1, and only right bundle branch block in 2 dogs, whereas no changes occurred in group 2. Pathologic examination in group-1 dogs showed complete or partial necrosis of the His bundle in 4 and complete necrosis of the right bundle branch in 5 dogs. In group 2, partial necrosis in the right bundle branch was found only in 1 dog. Using this pacing technique, the APs were 5.7±1.2 mm away from the His bundle located superiorly in 20 or inferiorly in 3 patients. All APs were successfully eliminated with 1 to 3 radiofrequency applications. No complications and recurrence occurred during a follow-up of 11.8±1.4 months. Differentiating the NF His from far-field His activations led to a high ablation success without atrioventricular block in para-Hisian AP patients. © 2017 American Heart Association, Inc.

  16. Incidence of catheter-related complications in patients with central venous or hemodialysis catheters: a health care claims database analysis.

    Science.gov (United States)

    Napalkov, Pavel; Felici, Diana M; Chu, Laura K; Jacobs, Joan R; Begelman, Susan M

    2013-10-16

    Central venous catheter (CVC) and hemodialysis (HD) catheter usage are associated with complications that occur during catheter insertion, dwell period, and removal. This study aims to identify and describe the incidence rates of catheter-related complications in a large patient population in a United States-based health care claims database after CVC or HD catheter placement. Patients in the i3 InVision DataMart® health care claims database with at least 1 CVC or HD catheter insertion claim were categorized into CVC or HD cohorts using diagnostic and procedural codes from the US Renal Data System, American College of Surgeons, and American Medical Association's Physician Performance Measures. Catheter-related complications were identified using published diagnostic and procedural codes. Incidence rates (IRs)/1000 catheter-days were calculated for complications including catheter-related bloodstream infections (CRBSIs), thrombosis, embolism, intracranial hemorrhage (ICH), major bleeding (MB), and mechanical catheter-related complications (MCRCs). Thirty percent of the CVC cohort and 54% of the HD cohort had catheter placements lasting <90 days. Catheter-related complications occurred most often during the first 90 days of catheter placement. IRs were highest for CRBSIs in both cohorts (4.0 [95% CI, 3.7-4.3] and 5.1 [95% CI, 4.7-5.6], respectively). Other IRs in CVC and HD cohorts, respectively, were thrombosis, 1.3 and 0.8; MCRCs, 0.6 and 0.7; embolism, 0.4 and 0.5; MB, 0.1 and 0.3; and ICH, 0.1 in both cohorts. Patients with cancer at baseline had significantly higher IRs for CRBSIs and thrombosis than non-cancer patients. CVC or HD catheter-related complications were most frequently seen in patients 16 years or younger. The risk of catheter-related complications is highest during the first 90 days of catheter placement in patients with CVCs and HD catheters and in younger patients (≤16 years of age) with HD catheters. Data provided in this study can be applied

  17. Evaluating two irrigation controllers under subsurface drip irrigated tomato crop

    International Nuclear Information System (INIS)

    Al-Ghobari, H.M.; Mohammad, F.S.; El Marazky, M.S.A.

    2016-01-01

    Smart systems could be used to improve irrigation scheduling and save water under Saudi Arabia’s present water crisis scenario. This study investigated two types of evapotranspiration-based smart irrigation controllers, SmartLine and Hunter Pro-C2, as promising tools for scheduling irrigation and quantifying plants’ water requirements to achieve water savings. The effectiveness of these technologies in reducing the amount of irrigation water was compared with the conventional irrigation scheduling method as a control treatment. The two smart irrigation sensors were used for subsurface irrigation of a tomato crop (cv. Nema) in an arid region. The results showed that the smart controllers significantly reduced the amount of applied water and increased the crop yield. In general, the Hunter Pro-C2 system saved the highest amount of water and produced the highest crop yield, resulting in the highest water irrigation efficiency compared with the SmartLine controller and the traditional irrigation schedule. It can be concluded that the application of advanced scheduling irrigation techniques such as the Hunter controller under arid conditions can realise economic benefits by saving large amounts of irrigation water.

  18. Evaluating two irrigation controllers under subsurface drip irrigated tomato crop

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ghobari, H.M.; Mohammad, F.S.; El Marazky, M.S.A.

    2016-07-01

    Smart systems could be used to improve irrigation scheduling and save water under Saudi Arabia’s present water crisis scenario. This study investigated two types of evapotranspiration-based smart irrigation controllers, SmartLine and Hunter Pro-C2, as promising tools for scheduling irrigation and quantifying plants’ water requirements to achieve water savings. The effectiveness of these technologies in reducing the amount of irrigation water was compared with the conventional irrigation scheduling method as a control treatment. The two smart irrigation sensors were used for subsurface irrigation of a tomato crop (cv. Nema) in an arid region. The results showed that the smart controllers significantly reduced the amount of applied water and increased the crop yield. In general, the Hunter Pro-C2 system saved the highest amount of water and produced the highest crop yield, resulting in the highest water irrigation efficiency compared with the SmartLine controller and the traditional irrigation schedule. It can be concluded that the application of advanced scheduling irrigation techniques such as the Hunter controller under arid conditions can realise economic benefits by saving large amounts of irrigation water.

  19. Radiofrequency Energy and Electrode Proximity Influences Stereoelectroencephalography-Guided Radiofrequency Thermocoagulation Lesion Size: An In Vitro Study with Clinical Correlation.

    Science.gov (United States)

    Staudt, Michael D; Maturu, Sarita; Miller, Jonathan P

    2018-02-16

    Radiofrequency thermocoagulation of epileptogenic foci via stereoelectroencephalography (SEEG) electrodes has been suggested as a treatment for medically intractable epilepsy, but reported outcomes have been suboptimal, possibly because lesions generated using conventional high-energy radiofrequency parameters are relatively small. To describe a technique of delivering low energy across separate SEEG electrodes in order to create large confluent radiofrequency lesions. The size and configuration of radiofrequency lesions using different radiofrequency intensity and interelectrode distance was assessed in egg whites. Magnetic resonance images (MRI) from 3 patients who had undergone radiofrequency lesion creation were evaluated to determine the contribution of lesion intensity and electrode separation on lesion size. Electroencephalography, MRI, and clinical data were assessed before and after lesion creation. Both in Vitro and in Vivo analysis revealed that less energy paradoxically produced larger lesions, with the largest possible lesions produced when radiofrequency power was applied for long duration at less than 3 W. Linear separation of electrodes also contributed to lesion size, with largest lesions produced when electrodes were separated by a linear distance of between 5 and 12 mm. Clinical lesions produced using these parameters were large and resulted in improvement in interictal and ictal activity. Radiofrequency lesions produced using low-energy delivery between SEEG electrodes in close proximity can produce a large lesion. These findings might have advantages for treatment of focal epilepsy.

  20. Radiofrequency ablation of hepatocellular carcinoma: Mono or multipolar?

    Science.gov (United States)

    Cartier, Victoire; Boursier, Jérôme; Lebigot, Jérôme; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Aubé, Christophe

    2016-03-01

    Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P radiofrequency failure. Failure rate was lower with the multipolar technique for tumors radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  1. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  2. Analysis of the effect of renal excretory system cooling during thermal radiofrequency ablation in an animal model

    Directory of Open Access Journals (Sweden)

    Andre Meireles

    2014-01-01

    Full Text Available Objective: Analysis of renal excretory system integrity and efficacy of radiofrequency ablation with and without irrigation with saline at 2 o C (SF2. Materials and Methods: The median third of sixteen kidneys were submitted to radiofrequency (exposition of 1 cm controlled by intra-surgical ultrasound, with eight minutes cycles and median temperature of 90 o C in eight female pigs. One excretory renal system was cooled with SF2, at a 30ml/min rate, and the other kidney was not. After 14 days of post-operatory, the biggest diameters of the lesions and the radiological aspects of the excretory system were compared by bilateral ascending pyelogram and the animals were sacrificed in order to perform histological analysis. Results: There were no significant differences between the diameters of the kidney lesions whether or not exposed to cooling of the excretory system. Median diameter of the cooled kidneys and not cooled kidneys were respectively (in mm: anteroposterior: 11.46 vs. 12.5 (p = 0.23; longitudinal: 17.94 vs. 18.84 (p = 0.62; depth: 11.38 vs. 12.25 (p = 0.47. There was no lesion of the excretory system or signs of leakage of contrast media or hydronephrosis at ascending pyelogram. Conclusion: Cooling of excretory system during radiofrequency ablation does not significantly alter generated coagulation necrosis or affect the integrity of the excretory system in the studied model.

  3. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    Science.gov (United States)

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Intracorporeal knotting of a femoral nerve catheter

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2015-01-01

    Full Text Available Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.

  5. Renal denervation for resistant hypertension using an irrigated radiofrequency balloon: 12-month results from the Renal Hypertension Ablation System (RHAS) trial.

    Science.gov (United States)

    Ormiston, John A; Watson, Timothy; van Pelt, Niels; Stewart, Ralph; Stewart, James T; White, Jonathon M; Doughty, Robert N; Stewart, Fiona; Macdonald, Rhona; Webster, Mark W I

    2013-05-20

    Renal denervation using the point-by-point application of radiofrequency energy delivered by the first-generation Symplicity system is effective in lowering office blood pressure but may be time-consuming. The OneShot Renal Denervation System with a balloon-mounted spiral electrode potentially shortens and simplifies the procedure. This study is a hypothesis-generating first-in-human study to assess feasibility, and to provide preliminary efficacy and safety data. Eligible patients had a baseline office systolic blood pressure ≥160 mmHg (or ≥150 mmHg for diabetics) and were on two or more antihypertensive medications. Nine patients were enrolled. The primary endpoint, the insertion of the OneShot balloon into each renal artery and the delivery of radiofrequency energy, was achieved in 8/9 (89%) of patients. The one failure (the first patient) was due to generator high-impedance safety shut-off threshold set too low for humans. Adverse events were minor. No patient developed renal artery stenosis. Baseline BP was 185.67 ± 18.7 mmHg and the reductions at 1, 3, 6 and 12 months were 30.1 ± 13.6 (p=0.0004), 34.2 ± 20.2 (p=0.002), 33.6 ± 32.2 (p=0.021) and 30.6 ± 22.0 (p=0.019). The OneShot renal denervation system successfully delivered radiofrequency energy to the renal arteries in a short and straightforward procedure. Australian New Zealand Clinical Trials Registry - URL: anzctr.org.au. Trial identification: ACTRN12611000987965.

  6. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  7. Pulse-dose radiofrequency treatment in pain management-initial experience.

    Science.gov (United States)

    Ojango, Christine; Raguso, Mario; Fiori, Roberto; Masala, Salvatore

    2018-05-01

    Radiofrequency procedures have been used for treating various chronic pain conditions for decades. These minimally invasive percutaneous treatments employ an alternating electrical current with oscillating radiofrequency wavelengths to eliminate or alter pain signals from the targeted site. The aim of the continuous radiofrequency procedure is to increase the temperature sufficiently to create an irreversible thermal lesion on nerve fibres and thus permanently interrupt pain signals. The pulsed radiofrequency procedure utilises short pulses of radiofrequency current with intervals of longer pauses to avert a temperature increase to the level of permanent tissue damage. The goal of these pulses is to alter the processing of pain signals, but to avoid relevant structural damage to nerve fibres, as seen in the continuous radiofrequency procedure. The pulse-dose radiofrequency procedure is a technical improvement of the pulsed radiofrequency technique in which the delivery mode of the current is adapted. During the pulse-dose radiofrequency procedure thermal damage is avoided. In addition, the amplitude and width of the consecutive pulses are kept the same. The method ensures that each delivered pulse keeps the same characteristics and therefore the dose is similar between patients. The current review outlines the pulse-dose radiofrequency procedure and presents our institution's chronic pain management studies.

  8. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  9. Low rate of asymptomatic cerebral embolism and improved procedural efficiency with the novel pulmonary vein ablation catheter GOLD: results of the PRECISION GOLD trial.

    Science.gov (United States)

    De Greef, Yves; Dekker, Lukas; Boersma, Lucas; Murray, Stephen; Wieczorek, Marcus; Spitzer, Stefan G; Davidson, Neil; Furniss, Steve; Hocini, Mélèze; Geller, J Christoph; Csanádi, Zoltan

    2016-05-01

    This prospective, multicentre study (PRECISION GOLD) evaluated the incidence of asymptomatic cerebral embolism (ACE) after pulmonary vein isolation (PVI) using a new gold multi-electrode radiofrequency (RF) ablation catheter, pulmonary vein ablation catheter (PVAC) GOLD. Also, procedural efficiency of PVAC GOLD was compared with ERACE. The ERACE study demonstrated that a low incidence of ACE can be achieved with a platinum multi-electrode RF catheter (PVAC) combined with procedural manoeuvres to reduce emboli. A total of 51 patients with paroxysmal atrial fibrillation (AF) (age 57 ± 9 years, CHA2DS2-VASc score 1.4 ± 1.4) underwent AF ablation with PVAC GOLD. Continuous oral anticoagulation using vitamin K antagonists, submerged catheter introduction, and heparinization (ACT ≥ 350 s prior to ablation) were applied. Cerebral magnetic resonance imaging (MRI) scans were performed within 48 h before and 16-72 h post-ablation. Cognitive function assessed by the Mini-Mental State Exam at baseline and 30 days post-ablation. New post-procedural ACE occurred in only 1 of 48 patients (2.1%) and was not detectable on MRI after 30 days. The average number of RF applications per patient to achieve PVI was lower in PRECISION GOLD (20.3 ± 10.0) than in ERACE (28.8 ± 16.1; P = 0.001). Further, PVAC GOLD ablations resulted in significantly fewer low-power (GOLD in combination with established embolic lowering manoeuvres results in a low incidence of ACE. Pulmonary vein ablation catheter GOLD demonstrates improved biophysical efficiency compared with platinum PVAC. ClinicalTrials.gov NCT01767558. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.

  10. A survey on monopolar radiofrequency treatment.

    Science.gov (United States)

    Suh, Dong Hye; Hong, Eun Sun; Kim, Hyun Joo; Lee, Sang Jun; Kim, Hei Sung

    2017-09-01

    This questionnaire-based study was aimed to measure the level of appreciation, awareness of the special tips, and practice patterns of monopolar radiofrequency among Korean dermatologists practicing a specific monopolar radiofrequency device (Thermage® Inc., Hayward, CA). A total of 82 surveys were analyzed to show that the majority of participants (78.8%) were highly satisfied with the outcomes of monopolar radiofrequency treatment. All respondents were aware of the Eye Tip 0.25 cm 2 , and the majority knew the difference between the Face tip (blue) and the Total tip (orange). Most (86.3%) agreed to the statement that 900 shots were appropriate for facial tightening in those between the ages of 35 and 65 years. 66.2% of participants reported to have perform monopolar radiofrequency to extra-facial sites within the past year. As for the tips, the Total tip was most popular for all body sties and the Big tip was favored for the abdomen, thighs and buttock. We hope our data allow dermatologists to better utilize monopolar radiofrequency. © 2017 Wiley Periodicals, Inc.

  11. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4100 Radiofrequency electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  12. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  13. Condensation irrigation a system for desalination and irrigation

    International Nuclear Information System (INIS)

    Lindblom, J.; Nordell, B

    2006-01-01

    condensation irrigation is a system for both desalination and irrigation. The principles is that humidified air is let into an underground horizontal pipe system, where the air is cooled by the ground and humidity falls out as fresh water. The humidification could e.g. be achieved by evaporation of seawater in solar stills or any other heat source. By using drainage pipes for underground air transportation the water percolates into the soil, thereby irrigating the land. This study focuses on drinking water production, which means that humid air is led into plan pipes where the condensed water is collected at the pipe endings. Numerical simulations gave a study-state diurnal mean water production of 1.8 kg per meter of pipe over a 50 m pipe. Shorter pipes result in a greater mean production rate. Since the heat transfer of drainage pipes would be greater, current study indicates that condensation irrigation is a promising method for desalination and irrigation. Performed studies in condensation irrigation started at LTU in 2003. Current paper reports the initial theoretical work on the system.(Author)

  14. Review of ultrasonic irrigation in endodontics: increasing action of irrigating solutions

    Science.gov (United States)

    Mozo, Sandra; Llena, Carmen

    2012-01-01

    Introduction: Effective irrigant delivery and agitation are prerequisites for successful endodontic treatment. Ultrasonic irrigation can be performed with or without simultaneous ultrasonic instrumentation. Existing literature reveals that ultrasonic irrigation may have a very positive effect on chemical, biological and physical debridement of the root canal system as investigated in many in vitro studies. Objective: The purpose of this review article was to summarize and discuss the available information concerning ultrasonic irrigation in endodontics. Methods: This article presents an overview of ultrasonic irrigation methods and their debridement efficacy. In this paper the relevant literature on passive ultrasonic irrigation is reviewed. Information from original scientific papers or reviews listed in MEDLINE and Cochrane were included in the review. Results: The use of ultrasound in the irrigation procedure results in improved canal cleanliness, better irrigant transfer to the canal system, soft tissue debridement, and removal of smear layer and bacteria. There are many in vitro studies, but there is a need to standardize protocols, and correlate the clinical efficacy of ultrasonic devices with improved treatment outcomes. Understanding the basis of ultrasonic irrigation is fundamental for clinicians and researchers to improve the design and use of ultrasonic irrigation. Key words:Ultrasonic irrigation, ultrasound, smear layer, endodontics. PMID:22143738

  15. Radiofrequency Ablation of Hepatic Cysts : Case Report

    International Nuclear Information System (INIS)

    Lee, Ye Ri; Kim, Pyo Nyun

    2005-01-01

    Radiofrequency ablation has been frequently performed on intra-hepatic solid tumor, namely, hepatocellular carcinoma, metastatic tumor and cholangio carcinoma, for take the cure. But, the reports of radiofrequency ablation for intrahepatic simple cysts are few. In vitro experiment of animal and in vivo treatment for intrahepatic cysts of human had been reported in rare cases. We report 4 cases of radiofrequency ablation for symptomatic intrahepatic cysts

  16. Ablation of liver metastases by radiofrequency

    International Nuclear Information System (INIS)

    Baere, T. de

    2012-01-01

    Radiofrequency is a thermal ablative technique that is most often used percuteanously under image guidance. Thermal damage is obtained through frictional heating of a high frequency current. The maximal volume of destruction obtained in one radiofrequency delivery is around 4 cm and consequently, best indication for treatment are tumours below 3 cm. When compared, radiofrequency and surgical removal for tumours below 25 mm in diameter demonstrated a rate of incomplete resection/ablation of 6% and 7.3% respectively. Median survival after the first radiofrequency of a liver metastasis of CRC is reported to be 24 to 52 months with a 5 years overall survival of 18 to 44%. The median overall survival increases from 22 to 48 months depending on the use of radiofrequency ablation as rescue treatment after failure of others, or as a first line treatment. For patients with a single tumour, less than 4 cm, the survival rates at 1, 3, and 5 years are respectively 97%, 84% and 40%, with a median survival of 50 months. Follow-up imaging requires to use contrast-enhanced CT or MRI, looking for local recurrences evidenced by local foci of enhancement at the periphery of the ablation zone. (author)

  17. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    Science.gov (United States)

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  18. 47 CFR 1.1310 - Radiofrequency radiation exposure limits.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency radiation exposure limits. 1... Procedures Implementing the National Environmental Policy Act of 1969 § 1.1310 Radiofrequency radiation... exposure to radiofrequency (RF) radiation as specified in § 1.1307(b), except in the case of portable...

  19. Multimodal supervision programme to reduce catheter associated urinary tract infections and its analysis to enable focus on labour and cost effective infection control measures in a tertiary care hospital in India.

    Science.gov (United States)

    Jaggi, Namita; Sissodia, Pushpa

    2012-10-01

    Catheter Associated Urinary Tract Infections (CAUTI) contribute 30%-40% of all the nosocomial infections and they are associated with substantially increased institutional death rates. A multimodal supervision program which incorporates training of the staff with respect to infection control measures can be effective in reducing the CAUTIs in hospitals. To assess the impact of a multimodal UTI supervision program on the CAUTI rates over a year, from January 2009 to December 2009, in a tertiary care hospital in India. A 215 bedded tertiary care private hospital. The CAUTI rates were analyzed for the first 6 months (January 2009-June 2009). A UTI supervision program was instituted in the month of July 2009, which included training with respect to the standard protocols for the sample collection and diagnosis, the bundle components of the urinary catheter checklist and hand hygiene practices. The impact was assessed as per the CAUTI rates in the subsequent months. The average CAUTI rate was reduced by 47.1% (from 10.6 to 5.6) after the introduction of the supervision program. This study presented the mean age of the patients with CAUTIs as 54.5 years and it showed an approximately equal contribution of both the sexes (52.94% in males and 47.05% in females). The impact analysis of the supervision program showed a reduction of 8.7% (from 23 days to 21 days) during the average duration of the catheterization. The adherence to the components of the urinary catheter check list was increased by 44.4% (p=0.069) and the hand hygiene compliance was increased by 56.4% (p=0.004) respectively after the interventions. Components like bladder irrigation and practising perineal cleaning were found to show no effect on the CAUTI rates. The most common labour and cost effective infection control measures as revealed by the supervision programme were adherence to the urinary catheter checklist components (indication for catheter insertion and change, asepsis maintenance during and

  20. Irrigation and Autocracy

    DEFF Research Database (Denmark)

    Bentzen, Jeanet Sinding; Kaarsen, Nicolai; Wingender, Asger Moll

    We show that societies with a history of irrigation-based agriculture have been less likely to adopt democracy than societies with a history of rainfed agriculture. Rather than actual irrigation, the empirical analysis is based on how much irrigation potentially can increase yields.Irrigation pot...

  1. Hemodynamic Change in Pulmonary Vein Stenosis after Radiofrequency Ablation: Assessment with Magnetic Resonance Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Doyoung; Jung, Jung Im; Oh, Yong Seog; Youn, Ho Joong [Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2012-11-15

    We present a case of pulmonary vein (PV) stenosis after radio-frequency (RF) ablation, in which a hemodynamic change in the pulmonary artery was similar to that of congenital PV atresia on time-resolved contrast-enhanced magnetic resonance angiography (TR-MRA). A 48-year-old man underwent RF ablation due to atrial fibrillation. The patient subsequently complained of hemoptysis, dyspnea on exertion, and right chest pain. Right PV stenosis after catheter ablation was diagnosed through chest computed tomography and lung perfusion scan. Pulmonary TR-MRA revealed the pulmonary artery via systemic arterial collaterals and draining systemic collateral veins. On a velocity-encoded cine image, the flow direction of the right pulmonary artery was reversed in the diastolic phase and the left pulmonary artery demonstrated continuous forward flow throughout the cardiac cycle. These hemodynamic changes were similar to those seen in congenital unilateral PV atresia.

  2. Drip irrigation using a PLC based adaptive irrigation system

    OpenAIRE

    Shahidian, S.; Serralheiro, R. P.; Teixeira, J. L.; Santos, F. L.; Oliveira, M. R. G.; Costa, J. L.; Toureiro, C.; Haie, Naim; Machado, R. M.

    2009-01-01

    Most of the water used by man goes to irrigation. A major part of this water is used to irrigate small plots where it is not feasible to implement full-scale Evapotranspiration based irrigation controllers. During the growth season crop water needs do not remain constant and varies depending on the canopy, growth stage and climate conditions such as temperature, wind, relative humidity and solar radiation. Thus, it is necessary to find an economic irrigation controller that can adapt the dail...

  3. Black-box modeling to estimate tissue temperature during radiofrequency catheter cardiac ablation: feasibility study on an agar phantom model

    International Nuclear Information System (INIS)

    Blasco-Gimenez, Ramón; Lequerica, Juan L; Herrero, Maria; Hornero, Fernando; Berjano, Enrique J

    2010-01-01

    The aim of this work was to study linear deterministic models to predict tissue temperature during radiofrequency cardiac ablation (RFCA) by measuring magnitudes such as electrode temperature, power and impedance between active and dispersive electrodes. The concept involves autoregressive models with exogenous input (ARX), which is a particular case of the autoregressive moving average model with exogenous input (ARMAX). The values of the mode parameters were determined from a least-squares fit of experimental data. The data were obtained from radiofrequency ablations conducted on agar models with different contact pressure conditions between electrode and agar (0 and 20 g) and different flow rates around the electrode (1, 1.5 and 2 L min −1 ). Half of all the ablations were chosen randomly to be used for identification (i.e. determination of model parameters) and the other half were used for model validation. The results suggest that (1) a linear model can be developed to predict tissue temperature at a depth of 4.5 mm during RF cardiac ablation by using the variables applied power, impedance and electrode temperature; (2) the best model provides a reasonably accurate estimate of tissue temperature with a 60% probability of achieving average errors better than 5 °C; (3) substantial errors (larger than 15 °C) were found only in 6.6% of cases and were associated with abnormal experiments (e.g. those involving the displacement of the ablation electrode) and (4) the impact of measuring impedance on the overall estimate is negligible (around 1 °C)

  4. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1997-08-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed.

  5. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    International Nuclear Information System (INIS)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong

    1997-01-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed

  6. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  7. Image-guided radiofrequency ablation of renal cell carcinoma

    International Nuclear Information System (INIS)

    Boss, Andreas; Clasen, Stephan; Pereira, Philippe L.; Kuczyk, Markus; Schick, Fritz

    2007-01-01

    The incidence of renal cell carcinoma is rising with the increased number of incidental detection of small tumours. During the past few years, percutaneous imaging-guided radiofrequency ablation has evolved as a minimally invasive treatment of small unresectable renal tumours offering reduced patient morbidity and overall health care costs. In radiofrequency ablation, thermal energy is deposited into a targeted tumour by means of a radiofrequency applicator. In recent studies, radiofrequency ablation was shown to be an effective and safe modality for local destruction of renal cell carcinoma. Radiofrequency applicator navigation can be performed via ultrasound, computed tomography or magnetic resonance guidance; however, ultrasound seems less favourable because of the absence of monitoring capabilities during ablation. On-line monitoring of treatment outcome can only be performed with magnetic resonance imaging giving the possibility of eventual applicator repositioning to ablate visible residual tumour tissue. Long-term follow-up is crucial to assess completeness of tumour ablation. New developments in ablation technology and radiological equipment will further increase the indication field for radiofrequency ablation of renal cell carcinoma. Altogether, radiofrequency ablation seems to be a promising new modality for the minimally invasive treatment of renal cell carcinoma, which was demonstrated to exhibit high short-term effectiveness. (orig.)

  8. Presence of left atrial diverticula, accessory appendages, and normal variant pulmonary venous anatomy diagnosed using MDCT and adverse outcomes following radiofrequency catheter ablation therapy in patients with drug-refractory atrial fibrillation: An exploratory study

    International Nuclear Information System (INIS)

    Patel, S.N.; French, A.; Mathias, H.; Lyen, S.; Hamilton, M.C.K.; Manghat, N.E.

    2013-01-01

    Aim: To determine the frequency of normal variation left atrial anatomy (NVLAA) (diverticula, accessory appendages) and normal variation pulmonary venous anatomy (NVPVA) in patients with atrial fibrillation (AF), and to determine whether the presence of these entities is associated with an increased recurrence of atrial arrhythmias following radiofrequency catheter ablation (RFCA). Materials and methods: All cardiac MDCT images performed prior to RFCA between November 2009 and May 2011 in patients with drug-refractory AF were retrospectively evaluated. The presence, type, and location of NVLAA and NVPVA, and outcome of RFCA were recorded. Success was defined as restoration of sinus rhythm. Results: Forty-six consecutive patients with a mean age of 59.8 (±9.7) years (76.1% male) underwent cardiac MDCT for anatomical planning prior to RFCA procedures. Fourteen (30.4%) patients had NVLAA, 35% of patients had NVPVA. Thirty (65%) patients had successful RFCA: 57% of these had a NVLAA, 67% had NVPVA. Sixteen (35%) patients had unsuccessful RFCA: 63% of these had a NVLAA, 56% had NVPVA. There was no significant association between the presence of NVLAA (p = 0.699), NVPVA (p = 0.197), or “NVLAA in the presence of normal pulmonary venous anatomy” (p = 0.589) and the outcome of RFCA. Conclusion: The presence of NVLAA and NVPVA appears unrelated to adverse outcome in patients undergoing RFCA for the treatment of drug-refractory AF

  9. Prevention of catheter-related blood stream infection.

    Science.gov (United States)

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  10. New-generation radiofrequency technology.

    Science.gov (United States)

    Krueger, Nils; Sadick, Neil S

    2013-01-01

    Radiofrequency (RF) technology has become a standard treatment in aesthetic medicine with many indications due to its versatility, efficacy, and safety. It is used worldwide for cellulite reduction; acne scar revision; and treatment of hypertrophic scars and keloids, rosacea, and inflammatory acne in all skin types. However, the most common indication for RF technology is the nonablative tightening of tissue to improve skin laxity and reduce wrinkles. Radiofrequency devices are classified as unipolar, bipolar, or multipolar depending on the number of electrodes used. Additional modalities include fractional RF; sublative RF; phase-controlled RF; and combination RF therapies that apply light, massage, or pulsed electromagnetic fields (PEMFs). This article reviews studies and case series on these devices. Radiofrequency technology for aesthetic medicine has seen rapid advancements since it was used for skin tightening in 2003. Future developments will continue to keep RF technology at the forefront of the dermatologist's armamentarium for skin tightening and rejuvenation.

  11. ROOT CANAL IRRIGANTS AND IRRIGATION TECHNIQUES: A REVIEW

    OpenAIRE

    Aniketh; Mohamed; Geeta; Nandakishore; Gourav Kumar; Patrick Timothy; Jayson Mathew; Sahle Abdul

    2015-01-01

    Root canal irrigation is not much emphasised in endodontic therapy. Most articles discussed are on root canal shaping and obturation not much emphasis is given for irrigation. There are many irrigation solutions which are introduced into market. The primary objective of root canal therapy is the ret ention of the pulpless or pulpally involved tooth with its associated periapical tissues in a healthy state. Achievement of this objective requires that the pulpal spaces and con...

  12. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    Science.gov (United States)

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  13. Analysis of Irrigation Water Quality at Kadawa Irrigation Project for Improved Productivity

    Directory of Open Access Journals (Sweden)

    AR Sanda

    2014-09-01

    Full Text Available In the face of water scarcity and the several negative consequences, such as water wastage, flooding, water logging, soil losses and production losses, conserving the finite amount of fresh water is a must. The quality of irrigation water must therefore be ascertained. The chemical quality of three sources of irrigation water from canal and drainage water, namely drainage water, fresh irrigation water from canal, and drainage/irrigation water mixture, were analyzed from Kadawa irrigation Project for year 2013 and 2014 cropping seasons, with the view to evaluating the potential risks associated with their use in irrigation and hence their suitability or otherwise for irrigation purposes. The analysis revealed that the use of drainage water alone for irrigation may result in problems associated with salinity, while a blend of drainage/irrigation water in the ratio of 1:1 is a viable means of water conservation and a good means of crop production. DOI: http://dx.doi.org/10.3126/ije.v3i3.11082 International Journal of Environment Vol.3(3 2014: 235-240

  14. [Peripheral intravenous catheter-related phlebitis].

    Science.gov (United States)

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  15. How safe is 1% alum irrigation in controlling intractable vesical hemorrhage?

    Science.gov (United States)

    Goswami, A K; Mahajan, R K; Nath, R; Sharma, S K

    1993-02-01

    A prospective study was done to evaluate the efficacy and safety of intravesical instillation of 1% alum solution in 12 cases of hematuria of vesical origin, uncontrolled by saline irrigation for 24 hours via a 3-way Foley catheter. There were 10 cases of transitional cell carcinoma and 2 of radiation cystitis. Complete response was noted in 6 patients and a partial response in 4. Local side effects included suprapubic pain and vesical tenesmus, which were controlled by antispasmodic and/or analgesic drugs. Transient low grade pyrexia (maximum up to 38.2C) was noted in 4 patients. Among the other various clinical and biochemical parameters, serum aluminum level and prothrombin time showed statistically highly significant changes. Serum aluminum increased from an average baseline value of 1.68 to 3.36 mumol./l. without clinical evidence of aluminum toxicity and with levels well below the recommended safe limit. Prothrombin time increased parallel with the increase in serum aluminum level to a maximum of 1 1/2 times the control. Prothrombin values, therefore, can be used clinically, since they are readily obtainable whereas serum aluminum levels are not. Vesical irrigation with 1% alum solution is a safe method to control hematuria of vesical origin in properly selected cases.

  16. Value of Micronester coils in port-catheter implantation for continuous hepatic arterial infusion chemotherapy with fixed catheter tip method

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko; White, Robert I.

    2008-01-01

    To retrospectively evaluate the use of Micronester coils in port-catheter implantation with the fixed catheter tip method in comparison with other previously used coils. The cohort of this study was 143 consecutive patients with unresectable advanced liver cancer for whom a port-catheter system was percutaneously implanted. In the most recent 32 patients, Micronester coils were used for catheter tip fixation. Details of embolic agents for fixation, persistent blood flow beyond the distal end of the indwelling catheter, and complications were compared between cases without and with Micronester coils. In all, percutaneous port-catheter placement was successful. Mean number of coils used for fixation was 4.2 without Micronester coils vs. 2.5 with Micronester coils. N-butyl cyanoacrylate (NBCA)-Lipiodol was additionally used for catheter tip fixation in 85.6% of 111 procedures without Micronester coils and in 50% of 32 using Micronester coils. The gastroduodenal artery beyond the distal end was not detected at the final examination after any procedure. Catheter dislocation occurred in five and hepatic arterial obstruction or severe stenosis in eight. The number of coils used and necessity of NBCA-Lipiodol could be decreased with usage of Micronester coils without decreasing fixation ability compared to other coils. (orig.)

  17. The effectiveness of a high output/short duration radiofrequency current application technique in segmental pulmonary vein isolation for atrial fibrillation

    DEFF Research Database (Denmark)

    Nilsson, Brian; Chen, Xu; Pehrson, Steen

    2006-01-01

    groups. In the conventional group (Group 1, 45 patients), the power output was limited to 30 W with a target temperature of 50 degrees C and an RF preset duration of 120 s. In the novel group (Group 2, 45 patients), the maximum power output was preset to 45 W, with a target temperature of 55 degrees C......AIMS: Segmental pulmonary vein (PV) isolation by radiofrequency (RF) catheter ablation has become a curative therapy for atrial fibrillation (AF). However, the long procedure time limits the wide application of this procedure. The aim of the current study was to compare a novel ablation technique...... and duration of 20 s. In Group 2, a significant reduction in the PV isolation time (127+/-57 vs. 94+/-33 min, P

  18. TYPES OF RADIOFREQUENCY ABLATION AND CLINICAL SYMPTOMS IN PATIENTS WITH ATRIAL FIBRILLATION AND FLUTTER

    Directory of Open Access Journals (Sweden)

    Zolotarova T. V.

    2017-12-01

    Full Text Available The study involved 76 patients with atrial fibrillation and atrial flutter (AF/AFL who were divided into groups depending on conducted surgery (radiofrequency ablation of pulmonary veins (RFA PV, cavo-tricuspid isthmus (CTI, a combined strategy (PV + CTI. We evaluated the sex and age of patients, AF and AFL form, duration of AF/AFL, classification of AF / AFL by the different scales, stage and degree of hypertension (AT; types of coronary heart disease (CHD; diabetes mellitus type 2; acute cerebrovascular accident history; functional class and stage of chronic heart failure (FC CHF. The frequency distribution of basic cardiovascular diseases and their clinical signs are observed equally in patients with AF/AFL, regardless of the type of surgery carried out and they do not influence the choice of the latter. Male patients often held RFA CTI and women – RFA PV. Patients with persistent AF often require alternative treatments, especially catheter ablation of arrhythmic substrate.

  19. Green and blue water footprint reduction in irrigated agriculture: effect of irrigation techniques, irrigation strategies and mulching

    Science.gov (United States)

    Chukalla, A. D.; Krol, M. S.; Hoekstra, A. Y.

    2015-12-01

    Consumptive water footprint (WF) reduction in irrigated crop production is essential given the increasing competition for freshwater. This study explores the effect of three management practices on the soil water balance and plant growth, specifically on evapotranspiration (ET) and yield (Y) and thus the consumptive WF of crops (ET / Y). The management practices are four irrigation techniques (furrow, sprinkler, drip and subsurface drip (SSD)), four irrigation strategies (full (FI), deficit (DI), supplementary (SI) and no irrigation), and three mulching practices (no mulching, organic (OML) and synthetic (SML) mulching). Various cases were considered: arid, semi-arid, sub-humid and humid environments in Israel, Spain, Italy and the UK, respectively; wet, normal and dry years; three soil types (sand, sandy loam and silty clay loam); and three crops (maize, potato and tomato). The AquaCrop model and the global WF accounting standard were used to relate the management practices to effects on ET, Y and WF. For each management practice, the associated green, blue and total consumptive WF were compared to the reference case (furrow irrigation, full irrigation, no mulching). The average reduction in the consumptive WF is 8-10 % if we change from the reference to drip or SSD, 13 % when changing to OML, 17-18 % when moving to drip or SSD in combination with OML, and 28 % for drip or SSD in combination with SML. All before-mentioned reductions increase by one or a few per cent when moving from full to deficit irrigation. Reduction in overall consumptive WF always goes together with an increasing ratio of green to blue WF. The WF of growing a crop for a particular environment is smallest under DI, followed by FI, SI and rain-fed. Growing crops with sprinkler irrigation has the largest consumptive WF, followed by furrow, drip and SSD. Furrow irrigation has a smaller consumptive WF compared with sprinkler, even though the classical measure of "irrigation efficiency" for furrow

  20. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject...

  1. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  2. Root canal irrigants

    OpenAIRE

    Kandaswamy, Deivanayagam; Venkateshbabu, Nagendrababu

    2010-01-01

    Successful root canal therapy relies on the combination of proper instrumentation, irrigation, and obturation of the root canal. Of these three essential steps of root canal therapy, irrigation of the root canal is the most important determinant in the healing of the periapical tissues. The primary endodontic treatment goal must thus be to optimize root canal disinfection and to prevent reinfection. In this review of the literature, various irrigants and the interactions between irrigants are...

  3. 21 CFR 876.5030 - Continent ileostomy catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Continent ileostomy catheter. 876.5030 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5030 Continent ileostomy catheter. (a) Identification. A continent ileostomy catheter is a flexible tubular device used as a form...

  4. FAQs about Catheter-Associated Urinary Tract Infection

    Science.gov (United States)

    ... do so. o Avoid disconnecting the catheter and drain tube. This helps to pre - vent germs from getting into the catheter tube. o The catheter is secured to the leg to prevent pulling on the ... regularly. The drainage spout should not touch any - thing while emptying ...

  5. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  6. The dangers of long-term catheter drainage.

    Science.gov (United States)

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  7. Radiofrequency initiation and radiofrequency sustainment of laser initiated seeded high pressure plasma

    International Nuclear Information System (INIS)

    Paller, Eric S.; Scharer, John E.; Akhtar, Kamran; Kelly, Kurt; Ding, Guowen

    2001-01-01

    We examine radiofrequency initiation of high pressure(1-70 Torr) inductive plasma discharges in argon, nitrogen, air and organic seed gas mixtures. Millimeter wave interferometry, optical emission and antenna wave impedance measurements for double half-turn helix and helical inductive antennas are used to interpret the rf/plasma coupling, measure the densities in the range of 10 12 cm -3 and analyze the ionization and excited states of the gas mixtures. We have also carried out 193 nm excimer laser initiation of an organic gas seed plasma which is sustained at higher pressures(150 Torr) by radiofrequency coupling at 2.8 kW power levels

  8. Biological safety evaluation of the modified urinary catheter

    Energy Technology Data Exchange (ETDEWEB)

    Kowalczuk, Dorota, E-mail: dorota.kowalczuk@umlub.pl [Department of Medicinal Chemistry, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin (Poland); Przekora, Agata; Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2015-04-01

    The purpose of this study was to evaluate in vitro safety of the novel tosufloxacin (TOS)-treated catheters with the prolonged antimicrobial activity. The test samples of silicone latex catheter were prepared by the immobilization of TOS on chitosan (CHIT)-coated catheter by means of covalent bonds and non-covalent interactions. Each step of the modification process of catheter surface was observed using ATR–Fourier transform infrared spectroscopy. In vitro cytotoxicity of the modified and unmodified catheters was assessed by direct and indirect tests in accordance with ISO standards using green monkey kidney (GMK) cell line. The MTT, lactate dehydrogenase activity (LDH), WST-8, Sulforhodamine B (SRB) test results and microscopic observation clearly indicated that unmodified silicone latex catheters decrease cell metabolic activity, act as a cytotoxic agent causing cell lysis and induce cell death through necrotic or apoptotic process. We suggest that chitosan coat with TOS immobilized limits leaching of harmful agents from silicone latex material, which significantly enhances survivability of GMK cells and therefore is quite a good protection against the cytotoxic effect of this material. - Highlights: • Characterization of the novel antimicrobial urinary catheters • Monitoring of the catheter modification by FTIR analysis • Confirmation of high cytotoxicity of latex-based catheter used in urological practice • Chitosan-coated and tosufloxacin-treated catheter is less toxic than the untreated one. • The proposed surface modification protects cells against latex-induced death.

  9. Reducing catheter-related thrombosis using a risk reduction tool centered on catheter to vessel ratio.

    Science.gov (United States)

    Spencer, Timothy R; Mahoney, Keegan J

    2017-11-01

    In vascular access practices, the internal vessel size is considered important, and a catheter to vessel ratio (CVR) is recommended to assist clinicians in selecting the most appropriate-sized device for the vessel. In 2016, new practice recommendations stated that the CVR can increase from 33 to 45% of the vessels diameter. There has been evidence on larger diameter catheters and increased thrombosis risk in recent literature, while insufficient information established on what relationship to vessel size is appropriate for any intra-vascular device. Earlier references to clinical standards and guidelines did not clearly address vessel size in relation to the area consumed or external catheter diameter. The aim of this manuscript is to present catheter-related thrombosis evidence and develop a standardized process of ultrasound-guided vessel assessment, integrating CVR, Virchow's triad phenomenon and vessel health and preservation strategies, empowering an evidence-based approach to device placement. Through review, calculation and assessment on the areas of the 33 and 45% rule, a preliminary clinical tool was developed to assist clinicians make cognizant decisions when placing intravascular devices relating to target vessel size, focusing on potential reduction in catheter-related thrombosis. Increasing the understanding and utilization of CVRs will lead to a safer, more consistent approach to device placement, with potential thrombosis reduction strategies. The future of evidence-based data relies on the clinician to capture accurate vessel measurements and device-related outcomes. This will lead to a more dependable data pool, driving the relationship of catheter-related thrombosis and vascular assessment.

  10. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    International Nuclear Information System (INIS)

    Wu, Tian-Tian; Li, Hu-Cheng; Zheng, Fang; Ao, Guo-Kun; Lin, Hu; Li, Wei-Min

    2016-01-01

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  11. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tian-Tian, E-mail: matthewwu1979@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com [The 307th Hospital of PLA, General Surgery Department (China); Zheng, Fang, E-mail: fang-zheng-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Ao, Guo-Kun, E-mail: guokun-ao-radiology@126.com; Lin, Hu, E-mail: hu-lin-radiology@126.com [The 309th Hospital of PLA, Radiology Department (China); Li, Wei-Min, E-mail: weimin-li-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China)

    2016-07-15

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  12. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    Science.gov (United States)

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (pPhlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  13. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    Science.gov (United States)

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  14. Spinal canal extension of hyperalimentation catheter without neurologic sequela

    International Nuclear Information System (INIS)

    Glasier, M.; Arkansas Children's Hospital, Little Rock; Hassell, D.R.

    1989-01-01

    An attempt at placement of a left femoral vein hyperalimentation catheter resulted in entrance of the catheter into the spinal canal. Catheter location was documented by injections of nonionic contrast material into the catheter without neurologic sequellae. (orig.)

  15. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    Directory of Open Access Journals (Sweden)

    Janete de Souza Urbanetto

    Full Text Available ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC and following their removal - (post-infusion phlebitis in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective.

  16. Cost effectiveness of day stay versus inpatient radiofrequency (RF) ablation for the treatment of supraventricular tachyarrhythmias

    International Nuclear Information System (INIS)

    Weerasooriya, H.R.; Harris, A.H.; Davis, M.J.E.

    1996-01-01

    It is well established that radiofrequency (RF) ablation is the most cost effective treatment strategy for patients with supraventricular tachycardia. Previous cost estimates assumed at least an overnight stay following RF ablation. Day stay RF ablation however appears to be a safe alternative. The aim of this study was to compare day stay and inpatient catheter ablation in terms of cost, efficacy and safety. This was a retrospective cost effectiveness analysis. The study population consisted of 25 consecutive patients who underwent impatient RF ablation (historical controls). Economic analysis was based upon a detailed clinical costing. The mean overall cost per patient of inpatient RF ablation in 1994 Australian dollar values is $2354 (SD, $642) compared with $1876 (SD, $595) for day stay RF ablation (p<0.01). Day stay RF ablation is a cost effective alternative to inpatient RF ablation. 16 refs., 2 tabs

  17. Endovascular Radiofrequency Ablation for Varicose Veins

    Science.gov (United States)

    2011-01-01

    or worse as other chronic diseases such as back pain and arthritis. Lower limb VV is a very common disease affecting adults – estimated to be the 7th most common reason for physician referral in the US. There is a very strong familial predisposition to VV. The risk in offspring is 90% if both parents affected, 20% when neither affected and 45% (25% boys, 62% girls) if one parent affected. The prevalence of VV worldwide ranges from 5% to 15% among men and 3% to 29% among women varying by the age, gender and ethnicity of the study population, survey methods and disease definition and measurement. The annual incidence of VV estimated from the Framingham Study was reported to be 2.6% among women and 1.9% among men and did not vary within the age range (40-89 years) studied. Approximately 1% of the adult population has a stasis ulcer of venous origin at any one time with 4% at risk. The majority of leg ulcer patients are elderly with simple superficial vein reflux. Stasis ulcers are often lengthy medical problems and can last for several years and, despite effective compression therapy and multilayer bandaging are associated with high recurrence rates. Recent trials involving surgical treatment of superficial vein reflux have resulted in healing and significantly reduced recurrence rates. Endovascular Radiofrequency Ablation for Varicose Veins RFA is an image-guided minimally invasive treatment alternative to surgical stripping of superficial venous reflux. RFA does not require an operating room or general anaesthesia and has been performed in an outpatient setting by a variety of medical specialties including surgeons and interventional radiologists. Rather than surgically removing the vein, RFA works by destroying or ablating the refluxing vein segment using thermal energy delivered through a radiofrequency catheter. Prior to performing RFA, color-flow Doppler ultrasonography is used to confirm and map all areas of venous reflux to devise a safe and effective

  18. Factors affecting irrigant extrusion during root canal irrigation: a systematic review

    NARCIS (Netherlands)

    Boutsioukis, C.; Psimma, Z.; van der Sluis, L.W.M.

    2013-01-01

    The aim of the present study was to conduct a systematic review and critical analysis of published data on irrigant extrusion to identify factors causing, affecting or predisposing to irrigant extrusion during root canal irrigation of human mature permanent teeth. An electronic search was conducted

  19. Hyperkalaemia after radiofrequency ablation of hepatocellular carcinoma

    NARCIS (Netherlands)

    Verhoevena, BH; Haagsma, EB; Appeltans, BMG; Slooff, MJH; de Jong, KP

    Radiofrequency ablation of liver tumours is a useful therapy for otherwise unresectable tumours. The complication rate is said to be low. In this case report we describe hyperkalaemia after radiofrequency ablation of a hepatocellular carcinoma in a patient with end-stage renal insufficiency. (C)

  20. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  1. Low Rates of Major Complications for Radiofrequency Ablation of Atrial Fibrillation Maintained Over 14 Years: A Single Centre Experience of 2750 Consecutive Cases.

    Science.gov (United States)

    Voskoboinik, Aleksandr; Sparks, Paul B; Morton, Joseph B; Lee, Geoffrey; Joseph, Stephen A; Hawson, Joshua J; Kistler, Peter M; Kalman, Jonathan M

    2018-02-03

    Despite technological advances, studies continue to report high complication rates for atrial fibrillation (AF) ablation. We sought to review complication rates for AF ablation at a high-volume centre over a 14-year period and identify predictors of complications. We reviewed prospectively collected data from 2750 consecutive AF ablation procedures at our institution using radiofrequency energy (RF) between January 2004 and May 2017. All cases were performed under general anaesthetic with transoesophageal echocardiography (TEE), 3D-mapping and an irrigated ablation catheter. Double transseptal puncture was performed under TEE guidance. All patients underwent wide antral circumferential isolation of the pulmonary veins (30W anteriorly, 25W posteriorly) with substrate modification at operator discretion. Of 2255 initial and 495 redo procedures, ablation strategies were: pulmonary vein isolation (PVI) only 2097 (76.3%), PVI+lines 368 (13.4%), PVI+posterior wall 191 (6.9%), PVI+cavotricuspid isthmus 277 (10.1%). There were 23 major (0.84%) and 20 minor (0.73%) complications. Cardiac tamponade (five cases - 0.18%) and phrenic nerve palsy (one case - 0.04%) rates were very low. Major vascular complications necessitating surgery or blood transfusion occurred in five patients (0.18%). There were no cases of death, permanent disability, atrio-oesophageal fistulae or symptomatic pulmonary vein (PV) stenosis, although there were five TEE probe-related complications (0.18%). Female gender (OR 2.14; 95% CI 1.07-4.26) but not age >70 (OR 1.01) was the only multivariate predictor of complications. Atrial fibrillation ablation performed at a high-volume centre using RF can be achieved with a low major complication rate in a representative AF population over a sustained period of time. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights

  2. Heart-type fatty acid binding protein is an early marker of myocardial damage after radiofrequency catheter ablation.

    Science.gov (United States)

    Giannessi, Daniela; Piacenti, Marcello; Maltinti, Maristella; Rossi, Andrea; Di Cecco, Pietro; Startari, Umberto; Cabiati, Manuela; Panchetti, Luca; Del Ry, Silvia; Morales, Maria-Aurora

    2010-10-01

    Radiofrequency (RF) ablation of arrhythmias induces myocardial damage and release of biomarkers. This study aimed to assess the kinetics of heart-type fatty acid-binding protein (h-FABP), a cytosolic protein released after myocardial injury incurred by both atrial and ventricular RF ablation, compared to other markers of myocardial injury. h-FABP, cTnI, CK-MB(mass) and myoglobin were evaluated in 30 patients with atrial or ventricular tachyarrhythmias before, immediately after and at 3, 6 and 24h after the procedure. h-FABP increased immediately after the procedure in all subjects (6.6 ± 1.2 μg/L vs 2.7 ± 0.3, pvalues of time for mean power of RF application in both the entire patient cohort and in ventricular ablations. h-FABP may be an early parameter for monitoring RF-induced lesions and the site of ablation was relevant for biomarker increase. Copyright © 2010 Elsevier Inc. All rights reserved.

  3. Radio-frequency integrated-circuit engineering

    CERN Document Server

    Nguyen, Cam

    2015-01-01

    Radio-Frequency Integrated-Circuit Engineering addresses the theory, analysis and design of passive and active RFIC's using Si-based CMOS and Bi-CMOS technologies, and other non-silicon based technologies. The materials covered are self-contained and presented in such detail that allows readers with only undergraduate electrical engineering knowledge in EM, RF, and circuits to understand and design RFICs. Organized into sixteen chapters, blending analog and microwave engineering, Radio-Frequency Integrated-Circuit Engineering emphasizes the microwave engineering approach for RFICs. Provide

  4. CATHETER DURATION AND THE RISK OF SEPSIS IN PREMATURE BABIES WITH UMBILICAL VEIN CATHETERS

    Directory of Open Access Journals (Sweden)

    Hartojo Hartojo

    2012-01-01

    Full Text Available Umbilical catheters are frequently required in the management of severely ill premature babies. The risk of complications may increase with duration of UVC use. Objective: To determine whether the risk of central line-associated bloodstream infections (CLA-BSIs and sepsis remained constant over the duration of umbilical vein catheters (UVCs in high-risk premature neonates. Methods:retrospective analysis. The data were collected from the medical record of high risk premature neonates who had a UVC placed in neonatal care unit of Husada Utama Hospital between April 1st 2008 to April 30th 2011 with purposive sampling. Catheter duration was observed before and after 14 days on placement. Blood and UVC culture was performed to establish the risk of CLA-BSIs and sepsis. Chi-square and logistic regression analysis were performed in the laboratorium data. Result: A total 44 high risk premature babies with UVCs were enrolled (sepsis group: n = 23 and non sepsis group: n = 21. Baseline demographics were similar between the groups. 15 babies in sepsis group have UVCs duration > 14 days, and 8 babies have UVCs 14 days show blood culture performance in 11 babies with positive evidence, UVCs culture performance is negative in 18 babies (p = 0.456. Burkholderia cepacia and Klebsiella pneumonia mostly appeared in blood culture performance. 25% of UVC culture performance shows Pseudomonas aeroginosa. Conclusions: The catheter duration have no significant difference in risk of sepsis in premature babies with Umbilical Vein Catheters.

  5. Obstruction of peritoneal dialysis catheter is associated with catheter type and independent of omentectomy: A comparative data analysis from a transplant surgical and a pediatric surgical department.

    Science.gov (United States)

    Radtke, Josephine; Schild, Raphael; Reismann, Marc; Ridwelski, Robert-Richard; Kempf, Caroline; Nashan, Bjoern; Rothe, Karin; Koch, Martina

    2018-04-01

    Peritoneal dialysis (PD) catheter occlusion is a common complication with up to 36% of catheter obstructions described in the literature. We present a comparison of complications and outcome after implantation of PD catheters in a transplant surgical and a pediatric surgical department. We retrospectively analyzed 154 PD catheters, which were implanted during 2009-2015 by transplant surgeons (TS, University Medical Center Hamburg-Eppendorf, Germany, n=85 catheters) and pediatric surgeons (PS, Charité University Medicine Berlin, Germany, n=69 catheters) in 122 children (median (range) age 3.0 (0.01-17.1) years) for acute (n=65) or chronic (n=89) renal failure. All catheters were one-cuffed or double-cuffed curled catheters, except that straight catheters were implanted into smaller children (n=19) by TS in Hamburg. Patient characteristics and operation technique did not differ between the departments. Peritonitis was the most common complication (33 catheters, 21.4%). Leakage (n=18 catheters, 11.7%) occurred more often in children weighing <10kg (p<0.001). The incidence of obstruction and dysfunction was significantly higher in catheters used in PS than catheters used in TS (30.4% vs. 11.8%, p=0.004). Omentectomy did not reduce the incidence of catheter obstruction (p=1.0). Perforation at the catheter tips was larger and appeared to be rougher in catheters used in PS than the catheters in TS. The type of catheter and presumably the type of perforation at the catheter tip may influence the incidence of peritoneal dialysis catheter obstruction. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Sustainable management after irrigation system transfer : experiences in Colombia - the RUT irrigation district

    NARCIS (Netherlands)

    Urrutia Cobo, N.

    2006-01-01

    Colombiais a tropical country located in South America. It has a total area of 114 million ha. In Colombia two irrigation sectors are distinguished: the small-scale irrigation and the large-scale irrigation sector. The small-scale irrigation sector is developed on lands

  7. Non-surgical radiofrequency facelift.

    Science.gov (United States)

    Narins, David J; Narins, Rhoda S

    2003-10-01

    There has been considerable interest in using non-ablative methods to rejuvenate the skin. The ThermaCool TC (Thermage Inc.) is a radiofrequency (RF) device that has been introduced to induce tightening of the address the problem of skin via a uniform volumetric heating into the deep dermis tightening, resulting in a 'non-surgical facelift'. Radiofrequency produces a uniform volumetric heating into the deep dermis. Twenty treatment areas in 17 patients were treated to evaluate the efficacy and safety of RF treatment to the brow and jowls. The technique was found to produce gradual tightening in most patients, and there were no adverse effects.

  8. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    Science.gov (United States)

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  9. Attitudes Towards Catheter Ablation for Atrial Fibrillation

    DEFF Research Database (Denmark)

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis

    2015-01-01

    BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...... cardiologists towards catheter ablation for AF, using a nationwide survey. METHODS AND RESULTS: We developed a purpose-designed questionnaire to evaluate attitudes towards catheter ablation for AF that was sent to all Danish cardiologists (n = 401; response n = 272 (67.8%)). There was no association between...... attitudes towards ablation and the experience or age of the cardiologist with respect to patients with recurrent AF episodes with a duration of 7 days and/or need for cardioversion. The majority (69%) expected a recurrence of AF after catheter ablation in more than 30% of the cases...

  10. 21 CFR 870.2910 - Radiofrequency physiological signal transmitter and receiver.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency physiological signal transmitter... Devices § 870.2910 Radiofrequency physiological signal transmitter and receiver. (a) Identification. A radiofrequency physiological signal transmitter and receiver is a device used to condition a physiological signal...

  11. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  12. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Abdel-Aal, A.K.; Gaddikeri, S.; Saddekni, S.

    2011-01-01

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  13. Detection of electrophysiology catheters in noisy fluoroscopy images.

    Science.gov (United States)

    Franken, Erik; Rongen, Peter; van Almsick, Markus; ter Haar Romeny, Bart

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust image analysis method that can detect the catheters in X-ray fluoroscopy images. Our method uses steerable tensor voting in combination with a catheter-specific multi-step extraction algorithm. The evaluation on clinical fluoroscopy images shows that especially the extraction of the catheter tip is successful and that the use of tensor voting accounts for a large increase in performance.

  14. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    Science.gov (United States)

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  15. Irrigation Training Manual. Planning, Design, Operation, and Management of Small-Scale Irrigation Systems [and] Irrigation Reference Manual. A Technical Reference to Be Used with the Peace Corps Irrigation Training Manual T0076 in the Selection, Planning, Design, Operation, and Management of Small-Scale Irrigation Systems.

    Science.gov (United States)

    Salazar, LeRoy; And Others

    This resource for trainers involved in irrigated agriculture training for Peace Corps volunteers consists of two parts: irrigation training manual and irrigation reference manual. The complete course should fully prepare volunteers serving as irrigation, specialists to plan, implement, evaluate and manage small-scale irrigation projects in arid,…

  16. Systematic review and meta-analysis: reminder systems to reduce catheter-associated urinary tract infections and urinary catheter use in hospitalized patients.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Macy, Michelle; Saint, Sanjay

    2010-09-01

    Prolonged catheterization is the primary risk factor for catheter-associated urinary tract infection (CAUTI). Reminder systems are interventions used to prompt the removal of unnecessary urinary catheters. To summarize the effect of urinary catheter reminder systems on the rate of CAUTI, urinary catheter use, and the need for recatheterization, we performed a systematic review and meta-analysis. Studies were identified in MEDLINE, the Cochrane Library, Biosis, the Web of Science, EMBASE, and CINAHL through August 2008. Only interventional studies that used reminders to physicians or nurses that a urinary catheter was in use or stop orders to prompt catheter removal in hospitalized adults were included. A total of 6679 citations were identified; 118 articles were reviewed, and 14 articles met the selection criteria. The rate of CAUTI (episodes per 1000 catheter-days) was reduced by 52% (P SMD) in the duration of catheterization was -1.11 overall (P = 070), including a statistically significant decrease in studies that used a stop order (SMD, -0.30; P = .001) but not in those that used a reminder (SMD, -1.54; P = .071). Recatheterization rates were similar in control and intervention groups. Urinary catheter reminders and stop orders appear to reduce the rate of CAUTI and should be strongly considered to enhance the safety of hospitalized patients.

  17. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner catheter to deliver stents for anomalous right coronary artery

    Directory of Open Access Journals (Sweden)

    Toshiki Kuno

    2015-10-01

    Full Text Available Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  18. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-01

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V 100 Prostate >90%) and organ-at-risk dose sparing (V 75 Bladder 75 Rectum 125 Urethra <<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... a catheter, x-ray imaging guidance and an injection of contrast material to examine blood vessels in ... technologies and, in most cases, a contrast material injection is needed to produce pictures of blood vessels ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... the American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available ... will regain their normal function within five to seven days. Rarely, the catheter punctures the artery, causing ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... Once the catheter is guided to the area being examined, a contrast material is injected through the ... You should inform your physician of any medications being taken and if there are any allergies, especially ...

  14. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  15. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    Science.gov (United States)

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  16. Removal of non-deflatable retained foley catheter in the bladder by percutaneous puncture of catheter balloon

    International Nuclear Information System (INIS)

    Yoo, Jae Duk; Kim, Jae Kyu; Park, Jin Gyun; Chung, Hyon De

    1988-01-01

    Nondeflatable Foley catheter in the bladder is an uncommon event. We recently experienced a patient in whom the urologist were unable to remove a Foley catheter with cystoscope due to public bone fractures. The procedure, which was successfully carried out, consists of puncturing the ballon under fluoroscope.

  17. Catheter-less robotic radical prostatectomy using a custom-made synchronous anastomotic splint and vesical urinary diversion device: report of the initial series and perioperative outcomes.

    Science.gov (United States)

    Tewari, Ashutosh; Rao, Sandhya; Mandhani, Anil

    2008-09-01

    To study the feasibility of avoiding a urethral catheter after robotic radical prostatectomy by using suprapubic diversion with a urethral splint, as urethral catheterization is often a source of major discomfort and pain to the patient, and can cause more concern to the patient than the procedure; we present the outcomes of a pilot study. This pilot study involved 30 patients; in group 1 (the study group of 10 patients) we used a custom-made suprapubic catheter which provided a small anastomotic splint, multiple holes for drainage and the ability to retract the splint to give a voiding trial before removing the drainage device. Group 2 was a control group of 20 patients who had standard urethral catheterization with an 18 F Silastic Foley catheter. Demographic, intraoperative and outcome data were measured and analysed. Urethral symptoms were recorded using a specially developed questionnaire. The two groups were comparable in terms of age, serum prostate specific antigen level, body mass index, Gleason scores, tumour stage, operative duration, amount of bleeding, console times, anastomotic leakage and postoperative retention rates. The study group had significantly less penile shaft or tip pain and discomfort during walking or sleeping. No patient in either group had haematuria or clot retention requiring irrigation. Urethral catheter-less robotic radical prostatectomy is feasible. The advantages are decreased penile shaft and tip pain, and decreased patient discomfort and an earlier return of continence.

  18. Iatrogenic Bowel Injury at Exchange of Supra-Pubic Catheter

    LENUS (Irish Health Repository)

    Foran, AT

    2018-04-01

    Suprapubic catheter insertion and exchange is a common urological procedure, but it is not without risks and complications. While bowel perforation is a recognised complication at suprapubic catheter insertion, it is not commonly reported at suprapubic catheter exchange. We report our experience of recognition, diagnosis and subsequent successful management of the most important complication related to suprapubic catheters.

  19. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Fan Shufeng Li Zheng; Gu Weizhong; Ru Fuming

    2006-01-01

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  20. The bowed catheter sign: a risk for pericardial tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Richard [Phoenix Children' s Hospital, Department of Radiology, Phoenix, AZ (United States)

    2008-03-15

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  1. The bowed catheter sign: a risk for pericardial tamponade

    International Nuclear Information System (INIS)

    Towbin, Richard

    2008-01-01

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  2. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    Science.gov (United States)

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  3. Catheter Associated Urinary Tract Infection Prevention bundle

    Directory of Open Access Journals (Sweden)

    O. Zarkotou

    2017-01-01

    Full Text Available Catheter-associated urinary tract infections (CAUTI are among the most common healthcare-associated infections, and potentially lead to significant morbidity and mortality. Multifaceted infection control strategies implemented as bundles can prevent nosocomial infections associated with invasive devices such as CAUTIs. The components of the CAUTI bundle proposed herein, include appropriate indications for catheterization and recommendations for the procedures of catheter insertion and catheter maintenance and care. Avoiding unnecessary urinary catheter use is the most effective measure for their prevention. To minimize the risk of CAUTI, urinary catheters should be placed only when a clinical valid indication is documented and they should be removed as soon as possible; alternatives to catheterization should also be considered. Aseptic insertion technique, maintenance of closed drainage system and strict adherence to hand hygiene are essential for preventing CAUTI. The successful implementation of the bundle requires education and training for all healthcare professionals and evaluation of surveillance data.

  4. Radiofrequency-thermoablation in malignant liver disease

    International Nuclear Information System (INIS)

    Pichler, L.; Anzboeck, W.; Paertan, G.; Hruby, W.

    2002-01-01

    The clinical application of radiofrequency tumor ablation in primary liver tumors and metastatic liver disease is rapidly growing because this technique has proven to be simple, safe, and effective in first clinical studies. Most of the patients with malignant liver disease are not candidates for surgical resection due localisation or comorbidity, so radiofrequency therapy offers a good alternative for inoperable patients. With this method, high frequency alternating current is delivered to tissue via a needle electrode, the produced heat leads to coagulation necrosis. The largest focus of necrosis that can be induced with the currently available systems is approximately 4-5 cm with a single application. The radiofrequency needle is usually placed with US or CT guidance. For follow up examinations CT and MRI can be used, they proved to be equally accurate in the assessment of treatment response. (orig.) [de

  5. Fractionated bipolar radiofrequency and bipolar radiofrequency potentiated by infrared light for treating striae: A prospective randomized, comparative trial with objective evaluation.

    Science.gov (United States)

    Harmelin, Yona; Boineau, Dominique; Cardot-Leccia, Nathalie; Fontas, Eric; Bahadoran, Philippe; Becker, Anne-Lise; Montaudié, Henri; Castela, Emeline; Perrin, Christophe; Lacour, Jean-Philippe; Passeron, Thierry

    2016-03-01

    Very few treatments for striae are based on prospective randomized trials. The objective of this study was to assess the efficacy of bipolar fractional radiofrequency and bipolar radiofrequency potentiated with infrared light, alone or combined, for treating abdominal stretch marks. Bicentric prospective interventional randomized controlled trial in the department of Dermatology of University Hospital of Nice and Aesthetics Laser Center of Bordeaux, France. Men and women of age 18 years or above, who presented for the treatment of mature or immature abdominal striae were included. The patients' abdomens were divided into four equal quadrants. Bipolar radiofrequency potentiated with infrared light and fractional bipolar radiofrequency were applied, alone or combined, and compared to the remaining untreated quadrant. The main criterion of evaluation was the measurement of depth of striae, using 3D photography at 6 months follow-up. A global assessment was also rated by the physician performing the treatment and by the patients. Histological analysis and confocal laser microscopy were additionally performed. A total of 22 patients were enrolled, and 384 striae were measured. In per protocol analysis mean striae depth was decreased by 21.64%, observed at 6 months follow-up with the combined approach, compared to an increase of 1.73% in the control group (P radiofrequency, combined with bipolar radiofrequency potentiated by infrared light, is an effective treatment of both immature and mature striae of the abdomen. © 2016 Wiley Periodicals, Inc.

  6. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  7. Temperature-controlled radiofrequency ablation of cardiac tissue

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1999-01-01

    BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequ......BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available...... for the frequently used temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size. METHODS AND RESULTS: In vitro strips......-controlled radiofrequency ablation increased external cooling of the electrode tip due to either flow of the surrounding liquid or poor electrode tissue contact, as exemplified by perpendicular versus parallel electrode orientation, increases lesion size significantly. This is in contrast to the impact of these factors...

  8. Pulsed Radiofrequency Ablation for Treating Sural Neuralgia.

    Science.gov (United States)

    Abd-Elsayed, Alaa; Jackson, Markus; Plovanich, Elizabeth

    2018-01-01

    Sural neuralgia is persistent pain in the distribution of the sural nerve that provides sensation to the lateral posterior corner of the leg, lateral foot, and fifth toe. Sural neuralgia is a rare condition but can be challenging to treat and can cause significant limitation. We present 2 cases of sural neuralgia resistant to conservative management that were effectively treated by pulsed radiofrequency ablation. A 65-year-old female developed sural neuralgia after a foot surgery and failed conservative management. She had successful sural nerve blocks, and pulsed radiofrequency ablation led to an 80% improvement in her pain. A 33-year-old female presented with sural neuralgia secondary to two falls. The patient had tried several conservative modalities with no success. We performed diagnostic blocks and pulsed radiofrequency ablation, and the patient reported 80% improvement in her pain. Pulsed radiofrequency ablation may be a safe and effective treatment for patients with sural neuralgia that does not respond to conservative therapy. However, studies are needed to elucidate its effectiveness and safety profile.

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  10. The enigma of candiduria: evolution of bladder irrigation with amphotericin B for management--from Anecdote to Dogma and a lesson from Machiavelli.

    Science.gov (United States)

    Sanford, J P

    1993-01-01

    Candiduria has emerged as a common, vexing diagnostic and therapeutic problem over the past 40 years. Treatment by means of bladder irrigation with a solution of amphotericin B has become widely used in clinical practice. However, the specifics of the procedure--concentration of amphotericin B, use of continuous washing vs. instillation with cross-clamping to allow "dwell-times," and duration of treatment--are based entirely on anecdotal experiences. The published reports and evolution of recommendations are reviewed. A prospective randomized double-blind study is needed to provide answers. In the meantime, administration of 200-300 mL of amphotericin B solution by triple-lumen urethral catheter with cross-clamping for 60-90 minutes seems most appropriate. Irrigation for no longer than 2 days should suffice if the procedure is to be effective. The optimal concentration of amphotericin B has not been defined; however, 5-10 mg/L appears adequate.

  11. An epidural catheter removal after recent percutaneous coronary intervention and coronary artery stenting: Epidural catheter and antiaggregation therapy

    Directory of Open Access Journals (Sweden)

    Joksić Nikola

    2016-01-01

    Full Text Available Introduction: Anticoagulation and antiplatelet therapy in the presence of the epidural catheter is still controversial. It is well known that dual antiplatelet therapy is indicated for 12 months after the placement of drug-eluting stents (DES. Removal of an epidural catheter during that period is related to an increased risk of stent occlusion in case of discontinuation of platelet function inhibitors or, on the other hand, increased risk of epidural hematoma associated with neurological deficit if suppressed platelet function is still present. Case Report: Here we present a case of a 63-year-old man who was admitted to Institute for Cardiovascular Diseases Dedinje for elective aortic surgery. Before the induction, an epidural catheter was inserted at the Th10-Th11 epidural space. Uneventful surgery was performed under the combined epidural and general anesthesia. On the 2nd postoperative day, the patient sustained a ST depression myocardial infarction treated with percutaneous coronary intervention with DES placement, while epidural catheter was still in place. Dual antiplatelet therapy with 600mg of clopidogrel, 100 mg of acetilsalicylic acid (ASA and low molecular weight heparin (LMWH were started during the procedure. The next day, clopidogrel (75 mg and ASA (100 mg were continued as well as LMWH. The decision to remove the epidural catheter was made on the 9th postoperative day, after platelet aggregation assays were performed. Six hours after catheter removal the patient again received clopidogrel, ASA and LMWH. There were no signs of epidural hematoma. Conclusion: This case shows that point-of-care testing with platelet aggregation assays may be useful in increasing the margin of safety for epidural catheter removal during dual antiplatelet therapy.

  12. Urethral catheters: can we reduce use?

    NARCIS (Netherlands)

    Broek, P.J. van den; Wille, J.C.; Benthem, B.H.B. van; Perenboom, R.J.M.; Akker-van Marle, M.E. van den; Nielen, A.M.A.

    2011-01-01

    Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. The efficacy of an intervention programme to improve adherence to

  13. Bacterial Biofilms and Catheters: A Key to Understanding Bacterial Strategies in Catheter-Associated Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    J Curtis Nickel

    1992-01-01

    Full Text Available Despite major technological improvements in catheter drainage systems, the indwelling Foley catheter remains the most common cause of nosocomial infection in medical practice. By approaching this common complicated urinary tract infection from the perspective of the biofilm strategy bacteria appear to use to overcome obstacles to produce bacteriuria, one appreciates a new understanding of these infections. An adherent biofilm of bacteria in their secretory products ascends the luminal and external surface of the catheter and drainage system from a contaminated drainage spigot or urethral meatus into the bladder. If the intraluminal route of bacterial ascent is delayed by strict sterile closed drainage or addition of internal modifications to the system, the extraluminal or urethral route assumes greater importance in the development of bacteriuria, but takes significantly longer. Bacterial growth within these thick coherent biofilms confers a large measure of relative resistance to antibiotics even though the individual bacterium remains sensitive, thus accounting for the failure of antibiotic therapy. With disruption of the protective mucous layer of the bladder by mechanical irritation, the bacteria colonizing the catheter can adhere to the bladder’s mucosal surface and cause infection. An appreciation of the role of bacterial biofilms in these infections should suggest future directions for research that may ultimately reduce the risk of catheter-associated infection.

  14. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    Science.gov (United States)

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  15. The Temporal Variation of Leaf Water Potential in Pistachio under Irrigated and Non-Irrigated Conditions

    Directory of Open Access Journals (Sweden)

    Yusuf AYDIN

    2014-09-01

    Full Text Available The present study was carried out in the experimental field of Pistachio Research Institute on pistachio trees which has uzun variety that was 30 years old. The aim of this research was to determine the Leaf Water Potential (LWP of Pistacia vera L. under irrigated and non-irrigated conditions. In the study, the leaf water potential of pistachio was investigated under fully irrigated and non irrigated conditions. The leaf water potential values were measured one day before and after irrigation by using pressure chamber technique at the beginning, mid and end of irrigation season. According to the results obtained from measurements, the LWP value at the beginning of the irrigation season was -3.7 MPa at noon time due to relatively high temperature for both treatments. At the time of pre-dawn and sunset, this value increased and reached to - 1.6 MPa due to relatively low temperature. In general, the LWP values during the mid of irrigation season, in the irrigated treatments, reached to almost -2.5 MPa in the non-irrigated treatment and the value was measured as -3.68 MPa.

  16. The radiofrequency frontier: a review of radiofrequency and combined radiofrequency pulsed-light technology in aesthetic medicine.

    Science.gov (United States)

    Sadick, Neil; Sorhaindo, Lian

    2005-05-01

    Radiofrequency (RF) and combined RF light source technologies have established themselves as safe and effective treatment modalities for several dermatologic procedures, including skin tightening, hair and leg vein removal, acne scarring, skin rejuvenation, and wrinkle reduction. This article reviews the technology, clinical applications, and recent advances of RF and combined RF light/laser source technologies in aesthetic medicine.

  17. Effect of low-cost irrigation methods on microbial contamination of lettuce irrigated with untreated wastewater

    DEFF Research Database (Denmark)

    Keraita, Bernard; Konradsen, Flemming; Drechsel, P.

    2007-01-01

    OBJECTIVE: To assess the effectiveness of simple irrigation methods such as drip irrigation kits, furrow irrigation and use of watering cans in reducing contamination of lettuce irrigated with polluted water in urban farming in Ghana. METHODS: Trials on drip kits, furrow irrigation and watering...... cans were conducted with urban vegetable farmers. Trials were arranged in a completely randomised block design with each plot having all three irrigation methods tested. This was conducted in both dry and wet seasons. Three hundred and ninety-six lettuce, 72 soil, 15 poultry manure and 32 water samples...... were analysed for thermotolerant coliforms and helminth eggs. RESULTS: Lettuce irrigated with drip kits had the lowest levels of contamination, with, on average, 4 log units per 100 g, fewer thermotolerant coliforms than that irrigated with watering cans. However, drip kits often got clogged, required...

  18. Catheter placement for lysis of spontaneous intracerebral hematomas: does a catheter position in the core of the hematoma allow more effective and faster hematoma lysis?

    Science.gov (United States)

    Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee

    2017-07-01

    For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.

  19. Types of urethral catheter for reducing symptomatic urinary tract infections in hospitalised adults requiring short-term catheterisation: multicentre randomised controlled trial and economic evaluation of antimicrobial- and antiseptic-impregnated urethral catheters (the CATHETER trial).

    Science.gov (United States)

    Pickard, R; Lam, T; Maclennan, G; Starr, K; Kilonzo, M; McPherson, G; Gillies, K; McDonald, A; Walton, K; Buckley, B; Glazener, C; Boachie, C; Burr, J; Norrie, J; Vale, L; Grant, A; N'dow, J

    2012-11-01

    Catheter-associated urinary tract infection (CAUTI) is a major preventable cause of harm for patients in hospital and incurs significant costs for health-care providers such as the UK NHS. Many preventative strategies and measures have been introduced to minimise CAUTI risk, including the use of antimicrobial catheters. However, there is considerable uncertainty regarding their usefulness in terms of reducing symptomatic CAUTI, and whether or not they are cost-effective. Do antimicrobial catheters reduce the rate of symptomatic urinary tract infection (UTI) during short-term hospital use and is their use cost-effective for the UK NHS? A pragmatic multicentre UK randomised controlled trial comparing three catheters as they would be used in the UK NHS: antimicrobial-impregnated (nitrofurazone) and antiseptic-coated (silver alloy) catheters with the standard polytetrafluoroethylene (PTFE)-coated catheters. Economic evaluation used a decision model populated with data from the trial. Sensitivity analysis was used to explore uncertainty. Relevant clinical departments in 24 NHS hospitals throughout the UK. Adults requiring temporary urethral catheterisation for a period of between 1 and 14 days as part of their care, predominantly as a result of elective surgery. Eligible participants were randomised 1 : 1 : 1 to one of three types of urethral catheter in order to make the following pragmatic comparisons: nitrofurazone-impregnated silicone catheter compared with standard PTFE-coated latex catheter; and silver alloy-coated hydrogel latex catheter compared with standard PTFE-coated latex catheter. The primary outcome for clinical effectiveness was the incidence of UTI at any time up to 6 weeks post randomisation. This was defined as any symptom reported during catheterisation, up to 3 days or 1 or 2 weeks post catheter removal or 6 weeks post randomisation combined with a prescription of antibiotics, at any of these times, for presumed symptomatic UTI. The primary economic

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... key areas of the body for abnormalities such as aneurysms and disease such as atherosclerosis (plaque). The use of a catheter makes ... including the: brain neck heart chest abdomen (such as the kidneys and liver) pelvis legs and feet ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  2. IRRIGATION USING SOLAR PUMP

    OpenAIRE

    Prof. Nitin P.Choudhary*1 & Ms. Komal Singne2

    2017-01-01

    In this report the described design of a PV and soil moisture sensor based automated irrigation system is introduced. This project aims to provide a human friendly, economical and automated water pumping system which eliminates the problems of over irrigation and helps in irrigation water optimization and manage it in accordance with the availability of water. Our project not only tries to modernize the irrigation practices and ensure the optimum yield by carefully fulfilling the requirements...

  3. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    International Nuclear Information System (INIS)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho

    2010-01-01

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate

  4. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  5. Treatment of acne vulgaris with fractional radiofrequency microneedling.

    Science.gov (United States)

    Kim, Sang Tae; Lee, Kang Hoon; Sim, Hyung Jun; Suh, Kee Suck; Jang, Min Soo

    2014-07-01

    Fractional radiofrequency microneedling is a novel radiofrequency technique that uses insulated microneedles to deliver energy to the deep dermis at the point of penetration without destruction of the epidermis. It has been used for the treatment of various dermatological conditions including wrinkles, atrophic scars and hypertrophic scars. There have been few studies evaluating the efficacy of fractional radiofrequency microneedling in the treatment of acne, and none measuring objective parameters like the number of inflammatory and non-inflammatory acne lesions or sebum excretion levels. The safety and efficacy of fractional radiofrequency microneedling in the treatment of acne vulgaris was investigated. In a prospective clinical trial, 25 patients with moderate to severe acne were treated with fractional radiofrequency microneedling. The procedure was carried out three times at 1-month intervals. Acne lesion count, subjective satisfaction score, sebum excretion level and adverse effects were assessed at baseline and at 4, 8 and 12 weeks after the first treatment as well as 4, 8 and 12 weeks after the last treatment. Number of acne lesions (inflammatory and non-inflammatory) decreased. Sebum excretion and subjective satisfaction were more favorable at every time point compared with the baseline values (P acne vulgaris. © 2014 Japanese Dermatological Association.

  6. Management of Non- Deflating Foley Suprapubic Catheters - A ...

    African Journals Online (AJOL)

    The procedure described uses a 10 ml syringe and needle passed through the lumen of the catheter to puncture the inner surface of the catheter balloon and thus deflate it. Because the catheter balloon does not burst in this procedure there is no risk of balloon fragmentation or subsequent stone formation. The technique is ...

  7. Urethral catheters: can we reduce use?

    Directory of Open Access Journals (Sweden)

    van den Akker-van Marle M Elske

    2011-05-01

    Full Text Available Abstract Background Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. Methods The efficacy of an intervention programme to improve adherence to recommendations to reduce the use of urethral catheters was studied in a before-after comparison in ten Dutch hospitals. The programme detected barriers and facilitators and each individual facility was supported with developing their own intervention strategy. Outcome was evaluated by the prevalence of catheters, alternatives such as diapers, numbers of urinary tract infections, the percentage of correct indications and the duration of catheterization. The costs of the implementation as well as the catheterization were evaluated. Results Of a population of 16,495 hospitalized patients 3335 patients of whom 2943 were evaluable for the study, had a urethral catheter. The prevalence of urethral catheters decreased insignificantly in neurology (OR 0.93; 95% CI 0.77 - 1.13 and internal medicine wards (OR 0.97; 95% CI 0.83 - 1.13, decreased significantly in surgical wards (OR 0.84; 95% CI 0.75 - 0.96, but increased significantly in intensive care (IC and coronary care (CC units (OR 1.48; 95% CI 1.01 - 2.17. The use of alternatives was limited and remained so after the intervention. Duration of catheterization decreased insignificantly in IC/CC units (ratio after/before 0.95; 95% CI 0.78 - 1.16 and neurology (ratio 0.97; 95% CI 0.80 - 1.18 and significantly in internal medicine (ratio 0.81; 95% CI 0.69 - 0.96 and surgery wards (ratio 0.80; 95% CI 0.71 - 0.90. The percentage of correct indications on the day of inclusion increased from 50 to 67% (p Conclusion Targeted implementation of recommendations from an existing guideline can lead to better adherence and cost savings. Especially, hospitals which use a lot of urethral catheters or

  8. Contribution to the improvement of irrigation management practices through water - deficit irrigation

    International Nuclear Information System (INIS)

    Bazza, M.

    1995-01-01

    The study aimed at identifying irrigation management practices which could result in water savings through -water deficit irrigation. Two field experiments, one on wheat and the other on sugar beet, were conducted and consisted of refraining from supplying water during specific stages of the cycle so as to identy the period(s) during which water deficit would have a limited effect on crop production. In the case of wheat, high water deficit occurred during the early and during these stages was the most beneficial for the crop. However, one water application during the tillering stage allowed the yield to be lower only to that of the treatement with three irrigations. Irrigation during the stage of grain filling caused the kernel weight to be as high as under three irrigations. The lowest value corresponded to the treatement with one irrigation during grain filling and that under rainfed conditions. For sugar beet, when water stress was was applied early in the crop cycle, its effect could be almost entirely recovered with adequate watering during the rest of the growing season. On the opposite, good watering early in cycle, followed by a stress, resulted in the second lowest yield. Water deficit during the maturity stage had also a limited effect on yield. The most crucial periods for adequate watering were which correspond to late filiar development and root growth which coincided with the highest water requirements period. For the same amount of water savings through deficit irrigation, it was better to partition the stress throughout the cycle than during the critical stages of the crop. However, at the national level, it would have been more important to practice deficit irrigation and the irrigated area. For both crops, high yields as high as water - use efficiency values could have been obtained. 8 tabs; 5 refs ( Author )

  9. 21 CFR 880.5200 - Intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  10. Pulmonary Arterial Hypertension in Adults: Novel Drugs and Catheter Ablation Techniques Show Promise? Systematic Review on Pharmacotherapy and Interventional Strategies

    Directory of Open Access Journals (Sweden)

    Salvatore Rosanio

    2014-01-01

    Full Text Available This systematic review aims to provide an update on pharmacological and interventional strategies for the treatment of pulmonary arterial hypertension in adults. Currently US Food and Drug Administration approved drugs including prostanoids, endothelin-receptor antagonists, phosphodiesterase type-5 inhibitors, and soluble guanylate-cyclase stimulators. These agents have transformed the prognosis for pulmonary arterial hypertension patients from symptomatic improvements in exercise tolerance ten years ago to delayed disease progression today. On the other hand, percutaneous balloon atrioseptostomy by using radiofrequency perforation, cutting balloon dilatation, or insertion of butterfly stents and pulmonary artery catheter-based denervation, both associated with very low rate of major complications and death, should be considered in combination with specific drugs at an earlier stage rather than late in the progression of pulmonary arterial hypertension and before the occurrence of overt right-sided heart failure.

  11. Automation of irrigation systems to control irrigation applications and crop water use efficiency

    Science.gov (United States)

    Agricultural irrigation management to slow water withdrawals from non-replenishing quality water resources is a global endeavor and vital to sustaining irrigated agriculture and dependent rural economies. Research in site-specific irrigation management has shown that water use efficiency, and crop p...

  12. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-04-01

    Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, pSMD) in catheterisation duration (days) was -1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD -0.37; pSMD, -1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits.

  13. Ghana - Agriculture - Irrigation

    Data.gov (United States)

    Millennium Challenge Corporation — The Millennium Development Authority (MiDA) financed the construction of a new irrigation scheme in Kpong and the renovation of two irrigation schemes in Botanga and...

  14. Local Intravascular Drug Delivery: In Vitro Comparison of Three Catheter Systems

    International Nuclear Information System (INIS)

    Alfke, Heiko; Wagner, Hans-Joachim; Calmer, Christian; Klose, Klaus Jochen

    1998-01-01

    Purpose: The aim of this in vitro study was to compare different catheter systems for local drug delivery with respect to the penetration depth of a biotin marker solution delivered into the vessel wall. Methods: Post-mortem carotid arteries from pigs were locally infused with a biotin solution using three different catheter systems. With all catheters (microporous balloon catheter, hydrogel-coated balloon catheter, and spiral balloon catheter) we used the same pressure of 405 kPa (4 atm) and infusion times of 60, 90, and 300 sec. After infusion the arteries were histologically prepared and stained using a biotin-specific method. With a light microscope an observer, blinded to the catheter type, scored the amount of biotin within the vessel wall, measured as staining intensity, and the penetration depth of the biotin. Results: Delivery with the hydrogel-coated balloon catheter was limited to the intima and the innermost parts of the media. The spiral balloon and microporous balloon catheter showed both a deeper penetration and a larger amount of delivered biotin compared with the hydrogel catheter, with a slightly deeper penetration using the microporous catheter. The penetration depth showed a correlation with infusion time for the spiral balloon and microporous catheters, but not for the hydrogel-coated catheter. Conclusion: Different catheter designs lead to different patterns of local drug delivery. The differences in penetration depth and amount of the substance delivered to the vessel wall should be known and might be useful for targeting specific areas within the vessel wall

  15. Dose requirements for UVC disinfection of catheter biofilms

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D.; Tvede, Michael

    2009-01-01

    Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required...... doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67......) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC...

  16. Miniaturization of catheter systems for angiography

    International Nuclear Information System (INIS)

    Hawkins, I.F. Jr.; Akins, E.W.

    1988-01-01

    The authors discuss the use of small catheters and needles in angiography and interventional procedures to improve the quality of the procedures and increase the success rate and safety. This philosophy was initially poorly received, both by operators and by industry; however, more recently microtechniques have become more acceptable primarily because of the changing economic climate requiring procedures with shorter or no hospitalization time. Since 1970, the authors have performed well over 10,000 angiographic procedures using 5 French catheters, or smaller. During the last 12 years, they have used almost exclusively 4 French catheters, primarily with standard filming techniques which have resulted in no thrombosed arteries, or significant hematoma formation

  17. Cryoballoon Catheter Ablation in Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Cevher Ozcan

    2011-01-01

    Full Text Available Pulmonary vein isolation with catheter ablation is an effective treatment in patients with symptomatic atrial fibrillation refractory or intolerant to antiarrhythmic medications. The cryoballoon catheter was recently approved for this procedure. In this paper, the basics of cryothermal energy ablation are reviewed including its ability of creating homogenous lesion formation, minimal destruction to surrounding vasculature, preserved tissue integrity, and lower risk of thrombus formation. Also summarized here are the publications describing the clinical experience with the cryoballoon catheter ablation in both paroxysmal and persistent atrial fibrillation, its safety and efficacy, and discussions on the technical aspect of the cryoballoon ablation procedure.

  18. Radiofrequency amplifier based on a DC superconducting quantum interference device

    International Nuclear Information System (INIS)

    Martinis, J.M.; Hilbert, C.; Clarke, J.

    1986-01-01

    A method is described of amplifying a radiofrequency signal consisting of: disposing a single symmetrically biased dc SQUID and an input coil within a superconducting shield, the dc SQUID having a superconducting ring interrupted by two shunted Josephson junctions, and the input coil being inductively coupled solely to the ring of the single SQUID, establishing a constant magnetic flux threading the SQUID ring, applying the radiofrequency signal to the input coil from outside of the superconducting shield, obtaining an amplified radiofrequency signal solely from across the ring of the single SQUID, transmitting the amplified radiofrequency signal from across the SQUID ring to the outside of the superconducting shield

  19. [Prevention of catheter-related infection: usefulness and cost-effectiveness of antiseptic catheters in children].

    Science.gov (United States)

    Lenz, Ana M; Vassallo, Juan C; Moreno, Guillermo E; Althabe, María; Gómez, Silvia; Magliola, Ricardo; Casimir, Lidia; Bologna, Rosa; Barretta, Jorge; Ruffa, Pablo

    2010-06-01

    To evaluate the cost-effectiveness of the antiseptic-impregnated catheter compared with conventional catheters in preventing catheter- related blood stream infections (CR-BSI). Cost-effectiveness analysis; clinical trial, experimental, randomized, controlled, prospective, open label. Patients and methods. A 172 patient cohort, under 1-year-old or less than 10 kg, postoperative cardiovascular children with central venous catheters (CVC) admitted to Cardiac Intensive Care Unit (UCI 35) at Hospital Nacional de Pediatría "Prof. Dr. Juan P. Garrahan", since September 2005 to December 2007. Demographic and CVC data were retrieved to compare: age, gender, weight, diagnosis, surgery, CVC days, costs and complications. Intervention. CVC Arrow, double-lumen, > 48 h of duration; intervention group: antiseptic-impregnated CVC vs. control group: CVC without antiseptics (conventional). The incidence of CR-IE (CR-Infected Events: colonization, local infection and/or CRBSI; combined end point) was 27% for antiseptic- impregnated CVC vs. 31% for conventional catheters (p= 0.6) with similar accumulated incidence of CR- BSI: 2.8 vs. 3.3 per 1000 dayscatheter. We found no differences between groups, except in weight: median 4.0 kg (r 2-17) vs. 4.7 kg (r 2-9) p= 0.0002 and age, median 2 months (r 1- 48) vs. 5 months (r 1- 24) p= 0.0019 in antiseptic-impregnated CVC group. These differences, though statistically significant were clinically non relevant. Median cost per patient during intensive care stay in the conventional CVC group was $3.417 (359-9.453) and in the antiseptic-impregnated-CVC group was $4.962 (239-24.532), p= 0.10. The use of antiseptic-impregnated CVC compared with conventional CVC did not decrease CR-BSI in this population. The cost per patients was higher in the antiseptic impregnated CVC group. These results do not support the routine use of this type of CVC in our population.

  20. New resonant circuits for the ISOLTRAP radiofrequency quadrupole trap

    CERN Document Server

    SENECAL, Pierre

    2015-01-01

    This report describes my work during my Summer Student Program. My main project was building and testing a resonance-circuit box for a radio-frequency power supply used with the radio-frequency cooler and buncher.

  1. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Burton, Kirsteen R.; Guo, Lancia L. Q.; Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K.

    2012-01-01

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  2. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  3. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    International Nuclear Information System (INIS)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T.; Akhan, Okan

    2011-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  4. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T. [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey); Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey)

    2011-11-15

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  5. Where does the pulmonary artery catheter float: Transesophageal echocardiography evaluation

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2015-01-01

    Full Text Available Background: Pulmonary artery (PA catheter provides a variety of cardiac and hemodynamic parameters. In majority of the patients, the catheter tends to float in the right pulmonary artery (RPA than the left pulmonary artery (LPA. We evaluated the location of PA catheter with the help of transesophageal echocardiography (TEE to know the incidence of its localization. Three views were utilized for this purpose; midesophageal ascending aorta (AA short-axis view, modified mid esophageal aortic valve long-axis view, and modified bicaval view. Methods: We enrolled 135 patients undergoing elective cardiac surgery where both the PA catheter and TEE were to be used; for this prospective observational study. PA catheter was visualized by TEE in the above mentioned views and the degree of clarity of visualization by three views was also noted. Position of the PA catheter was further confirmed by a postoperative chest radiograph. Results: One patient was excluded from the data analysis. PA catheter was visualized in RPA in 129 patients (96% and in LPA in 4 patients (3%. In 1 patient, the catheter was visualized in main PA in the chest radiograph. The midesophageal AA short-axis, modified aortic valve long-axis, and modified bicaval view provided good visualization in 51.45%, 57.4%, and 62.3% patients respectively. Taken together, PA catheter visualization was good in 128 (95.5% patients. Conclusion: We conclude that the PA catheter has a high probability of entering the RPA as compared to LPA (96% vs. 3% and TEE provides good visualization of the catheter in RPA.

  6. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  7. Magnetic catheter manipulation in the interventional MR imaging environment.

    Science.gov (United States)

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  8. Positioning of nasobiliary tube using magnet-loaded catheters.

    Science.gov (United States)

    Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke

    2013-10-01

    In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Intravascular catheter related infections in children admitted on the ...

    African Journals Online (AJOL)

    peripheral venous intravascular catheters uncoated with no antibiotic or antiseptic, was done. Social demographic characteristics, anthropometry, clinical examination including the catheter site were determined at enrollment. The children had their blood, catheter tip and hub samples taken off for culture and sensitivity as ...

  10. Traditional Irrigation Management in Betmera-Hiwane, Ethiopia: The Main Peculiarities for the Persistence of Irrigation Practices

    Institute of Scientific and Technical Information of China (English)

    Solomon Habtu; Kitamura Yoshinobu

    2006-01-01

    Traditional irrigation, as part of the ancient agricultural practices in northern Ethiopia (Tigray), has persisted for long time since 500 B.C.,while many newly introduced irrigation projects have usually failed there. The main objective of this study is thus to investigate the peculiarities pertinent to irrigation management and those having contributed for the persistence of traditional irrigation practices for a long period of time. The experience gained from such areas can definitely help make irrigation management system of new irrigation schemes sustainable. Betmera-Hiwane, one of the ancient traditional irrigation areas in Tigray region, was selected for the field study. Direct observations through field visits accompanied by interviews to farmers, local officials, local knowledgeable individuals and higher officials were made. After analyzing the collected primary and secondary information, the main peculiarities that contributed to the persistence of traditional irrigation areas were identified, and they are: the presence of communally constructed local rules, locally designed hydraulic control structures, ownership feeling of the irrigators and accountability of water distributors to the irrigation management, the culture for mobilizing communal resources and the culture of self-initiating local water management strategies.

  11. Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications.

    Science.gov (United States)

    Trinidad, José Manuel; Carnota, Ana Isabel; Failde, Inmaculada; Torres, Luis Miguel

    2015-01-01

    Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%). The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied). We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.

  12. Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications

    Directory of Open Access Journals (Sweden)

    José Manuel Trinidad

    2015-01-01

    Full Text Available Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied. We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.

  13. Modernized Irrigation Technologies in West Africa

    Directory of Open Access Journals (Sweden)

    Hakan Büyükcangaz

    2017-12-01

    Full Text Available Crop production in West Africa is mostly dependent upon rainfed agriculture. Irrigation is a vital need due to uneven distribution of rainfall and seasonality of water resources. However, management and sustainability of irrigation are under risk due to notably weak database, excessive cost, unappropriate soil or land use, environmental problems and extreme pessimism in some quarters since rainfed agriculture is seen as potentially able to support the present population. This paper focuses on modernized irrigation technologies and systems that utilize less water. Information about irrigation systems in Ghana and Liberia were gathered through: 1 Irrigation development authorities in both countries, by reviewing past literatures, online publications, reports and files about irrigation in West Africa, specifically Ghana and Liberia; 2 International Food Policy Research Institute (IFPRI; 3 Collation of information, reports and data from Ghana Irrigation Development Authority (GIDA and 4 International Water Management Institute (IWMI. The result shows that both countries have higher irrigation potential. However, the areas developed for irrigation is still a small portion as compare to the total land available for irrigation. On the other hand, as seen in the result, Liberia as compare to Ghana has even low level of irrigation development.

  14. Irrigation in endodontic treatment.

    Science.gov (United States)

    Basrani, Bettina

    2011-01-01

    The primary endodontic treatment goal is to optimize root canal disinfection and to prevent reinfection. Successful root canal therapy relies on the combination of proper instrumentation, irrigation, and obturation of the root canal system. In this review of the literature, various irrigants and the interactions between irrigants are discussed and new delivery systems are introduced.

  15. The effect of irrigation time and type of irrigation fluid on cartilage surface friction.

    Science.gov (United States)

    Stärke, F; Awiszus, F; Lohmann, C H; Stärke, C

    2018-01-01

    It is known that fluid irrigation used during arthroscopic procedures causes a wash-out of lubricating substances from the articular cartilage surface and leads to increased friction. It was the goal of this study to investigate whether this effect depends on the time of irrigation and type of fluid used. Rabbit hind legs were used for the tests. The knees were dissected and the friction coefficient of the femoral cartilage measured against glass in a boundary lubrication state. To determine the influence of irrigation time and fluid, groups of 12 knees received either no irrigation (control), 15, 60 or 120min of irrigation with lactated Ringer's solution or 60min of irrigation with normal saline or a sorbitol/mannitol solution. The time of irrigation had a significant effect on the static and kinetic coefficient of friction (CoF), as had the type of fluid. Longer irrigation time with Ringer's solution was associated with increased friction coefficients (relative increase of the kinetic CoF compared to the control after 15, 60 and 120min: 16%, 76% and 88% respectively). The sorbitol/mannitol solution affected the static and kinetic CoF significantly less than either Ringer's or normal saline. The washout of lubricating glycoproteins from the cartilage surface and the associated increase of friction can be effectively influenced by controlling the time of irrigation and type of fluid used. The time of exposure to the irrigation fluid should be as short as possible and monosaccharide solutions might offer a benefit compared to salt solutions in terms of the resultant friction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Carbon and water footprints of irrigated corn and non-irrigated wheat in Northeast Spain.

    Science.gov (United States)

    Abrahão, Raphael; Carvalho, Monica; Causapé, Jesús

    2017-02-01

    Irrigation increases yields and allows several crops to be produced in regions where it would be naturally impossible due to limited rainfall. However, irrigation can cause several negative environmental impacts, and it is important to understand these in depth for the correct application of mitigation measures. The life cycle assessment methodology was applied herein to compare the main irrigated and non-irrigated crops in Northeast Spain (corn and wheat, respectively), identifying those processes with greater contribution to environmental impacts (carbon and water footprint categories) and providing scientifically-sound information to facilitate government decisions. Due to concerns about climate change and water availability, the methods selected for evaluation of environmental impacts were IPCC 2013 GWP (carbon footprint) and water scarcity indicator (water footprint). The area studied, a 7.38-km 2 basin, was monitored for 12 years, including the period before, during, and after the implementation of irrigation. The functional unit, to which all material and energy flows were associated with, was the cultivation of 1 ha, throughout 1 year. The overall carbon footprint for irrigated corn was higher, but when considering the higher productivity achieved with irrigation, the emissions per kilogram of corn decrease and finally favor this irrigated crop. When considering the water footprint, the volumes of irrigation water applied were so high that productivity could not compensate for the negative impacts associated with water use in the case of corn. Nevertheless, consideration of productivities and gross incomes brings the results closer. Fertilizer use (carbon footprint) and irrigation water (water footprint) were the main contributors to the negative impacts detected.

  17. Making the user visible: analysing irrigation practices and farmers’ logic to explain actual drip irrigation performance

    NARCIS (Netherlands)

    Benouniche, M.; Kuper, M.; Hammani, A.; Boesveld, H.

    2014-01-01

    The actual performance of drip irrigation (irrigation efficiency, distribution uniformity) in the field is often quite different from that obtained in experimental stations. We developed an approach to explain the actual irrigation performance of drip irrigation systems by linking measured

  18. The importance of effective catheter securement.

    Science.gov (United States)

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use.

  19. Treatment of Benign Thyroid Nodules: Comparison of Surgery with Radiofrequency Ablation.

    Science.gov (United States)

    Che, Y; Jin, S; Shi, C; Wang, L; Zhang, X; Li, Y; Baek, J H

    2015-07-01

    Nodular goiter is one of the most common benign lesions in thyroid nodule. The main treatment of the disease is still the traditional surgical resection, however there are many problems such as general anesthesia, surgical scar, postoperative thyroid or parathyroid function abnormalities, and high nodules recurrence rate in residual gland. The purpose of this study was to compare the efficacy, safety, and cost-effectiveness of 2 treatment methods, surgery and radiofrequency ablation, for the treatment of benign thyroid nodules. From May 2012 to September 2013, 200 patients with nodular goiters who underwent surgery (group A) and 200 patients treated by radiofrequency ablation (group B) were enrolled in this study. Inclusion criteria were the following: 1) cosmetic problem, 2) nodule-related symptoms, 3) hyperfunctioning nodules related to thyrotoxicosis, and 4) refusal of surgery (for group B). An internally cooled radiofrequency ablation system and an 18-ga internally cooled electrode were used. We compared the 2 groups in terms of efficacy, safety, and cost-effectiveness during a 1-year follow-up. After radiofrequency ablation, the nodule volume decreased significantly from 5.4 to 0.4 mL (P = .002) at the 12-month follow-up. The incidence of complications was significantly higher from surgery than from radiofrequency ablation (6.0% versus 1.0%, P = .002). Hypothyroidism was detected in 71.5% of patients after surgery but in none following radiofrequency ablation. The rate of residual nodules (11.9% versus 2.9%, P = .004) and hospitalization days was significantly greater after surgery (6.6 versus 2.1 days, P radiofrequency ablation are both effective treatments of nodular goiter. Compared with surgery, the advantages of radiofrequency ablation include fewer complications, preservation of thyroid function, and fewer hospitalization days. Therefore, radiofrequency ablation should be considered a first-line treatment for benign thyroid nodules. © 2015 by American

  20. Efficacy of a one-catheter concept for transradial coronary angiography.

    Directory of Open Access Journals (Sweden)

    Christoph Langer

    Full Text Available Transradial coronary angiography (TRC can be performed with a one-catheter approach for the right and left coronary ostium (R/LCO. We investigated the performance of a special diagnostic catheter widely used for the one-catheter-approach, the Tiger (Tiger II, TerumoTM.In a dual center registry we analyzed 1412 TRC-procedures exclusively performed by experienced TRC-operators. We compared the performance of the Tiger with Judkins catheters by retrospectively judging ostial catheter stability during contrast injection, and by measuring contrast use, fluoroscopy time (FT and complication rate.Poor or failed ostial engagement was found in 40.5% in the Tiger group, compared to 46.6% with the use of Judkins catheters (p<0.183. Ostial instability of the Tiger was found more often during engagement of the LCO than the RCO (34.4% vs. 10.8%, p<0.001, whereas it was similar in the LCO and RCO for Judkins catheters (27.4% vs. 26.7%, p = 0.840. TRC-procedures performed with Tiger catheters were associated with less contrast volume (63.48 ± 29.83mL vs. 82.51 ± 56.58mL, p<0.004 and shorter FT than with Judkins catheters. (198.27 ± 194.8sec vs. 326.85 ± 329.70sec. Forearm hematomas occurred less often with the Tiger (1.2% vs. 6.6%, p< 0.02.The Tiger employed as a single catheter in TRC is an effective tool to achieve lower contrast volume and fluoroscopy time at a low complication rate. Unstable engagement affects predominantly the left coronary artery, but its overall frequency is similar for both, the Tiger and Judkins catheters.

  1. How Patients Experience Antral Irrigation

    Directory of Open Access Journals (Sweden)

    Karin Blomgren

    2015-01-01

    Full Text Available Background Antral irrigation earlier had an important role in the diagnosis and treatment of rhinosinusitis. Nowadays, it is often considered too unpleasant. However, the experience of patients of this procedure has been very seldom evaluated. Nor has the effect on pain in rhinosinusitis been evaluated. The aim of this study was to evaluate patients’ experience of discomfort and pain during antral irrigation. We also assessed facial pain caused by rhinosinusitis before the procedure and pain soon after the procedure. Methods Doctors and 121 patients completed their questionnaires independently after antral irrigation in a university clinic, in a private hospital, and at a communal health center. Results Patients experienced mild pain during antral irrigation (mean and median visual analog scale score: <3. Their experience of pain during antral irrigation was closely comparable to pain during dental calculus scaling. Facial pain assessed before antral irrigation decreased quickly after the procedure. Conclusions Antral irrigation was well tolerated as an outpatient procedure. The procedure seems to relieve facial pain caused by the disease quickly. The role of antral irrigation in the treatment of acute rhinosinusitis will need further investigation.

  2. Feedforward Coordinate Control of a Robotic Cell Injection Catheter.

    Science.gov (United States)

    Cheng, Weyland; Law, Peter K

    2017-08-01

    Remote and robotically actuated catheters are the stepping-stones toward autonomous catheters, where complex intravascular procedures may be performed with minimal intervention from a physician. This article proposes a concept for the positional, feedforward control of a robotically actuated cell injection catheter used for the injection of myogenic or undifferentiated stem cells into the myocardial infarct boundary zones of the left ventricle. The prototype for the catheter system was built upon a needle-based catheter with a single degree of deflection, a 3-D printed handle combined with actuators, and the Arduino microcontroller platform. A bench setup was used to mimic a left ventricle catheter procedure starting from the femoral artery. Using Matlab and the open-source video modeling tool Tracker, the planar coordinates ( y, z) of the catheter position were analyzed, and a feedforward control system was developed based on empirical models. Using the Student's t test with a sample size of 26, it was determined that for both the y- and z-axes, the mean discrepancy between the calibrated and theoretical coordinate values had no significant difference compared to the hypothetical value of µ = 0. The root mean square error of the calibrated coordinates also showed an 88% improvement in the z-axis and 31% improvement in the y-axis compared to the unmodified trial run. This proof of concept investigation leads to the possibility of further developing a feedfoward control system in vivo using catheters with omnidirectional deflection. Feedforward positional control allows for more flexibility in the design of an automated catheter system where problems such as systemic time delay may be a hindrance in instances requiring an immediate reaction.

  3. Modernisation Strategy for National Irrigation Systems in the Philippines: Balanac and Sta. Maria River Irrigation Systems

    NARCIS (Netherlands)

    Delos Reyes, M.L.F.

    2017-01-01

    This book examines the nature and impact of irrigation system rehabilitation on increasing the actual area irrigated by the publicly funded canal irrigation systems of the Philippines. It proposes a system diagnosis approach for the development of a more appropriate and climate-smart irrigation

  4. An intervention to improve the catheter associated urinary tract infection rate in a medical intensive care unit: Direct observation of catheter insertion procedure.

    Science.gov (United States)

    Galiczewski, Janet M; Shurpin, Kathleen M

    2017-06-01

    Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Femoral venous catheters: a safe alternative for delivering parenteral alimentation.

    Science.gov (United States)

    Friedman, B; Kanter, G; Titus, D

    1994-04-01

    Femoral vein catheterization is an alternative method of obtaining central venous access. Placement of femoral venous catheters (FVCs) is possible in the majority of patients, suitable for most indications, and associated with a low complication rate during insertion. We wished to determine the incidence of infections or other complications resulting when parenteral nutrition was delivered through FVCs. Fifty-two patients were followed from a hospital-wide population including patients in the critical care units. Triple-lumen catheters were placed by using the sterile Seldinger technique, and sites were examined daily for inflammation. Bacteriologic surveillance was accomplished by submitting the catheter tip for semiquantitative cultures. If catheter line sepsis was suspected, blood samples for cultures were drawn through the catheter and peripherally. The rate of occurrence of colonized catheters was 9.6% (five of 52), and catheter sepsis was found in one case (1.9%). Other than inflammation at six (11.5%) of 52 catheter sites, noninfectious complications of FVCs were not found. On the basis of these findings, we consider FVC-delivered parenteral alimentation a safe and effective alternative to other forms of central venous access.

  6. Amiodarone and Catheter Ablation as Cardiac Resynchronization Therapy for Children with Dilated Cardiomyopathy and Wolff-Parkinson-White Syndrome

    Science.gov (United States)

    Kim, Sung Hoon; Jeong, Soo In; Kang, I-Seok; Lee, Heung Jae

    2013-01-01

    Preexcitation by accessory pathways (APs) is known to cause dyssynchrony of the ventricle, related to ventricular dysfunction. Correction of ventricular dyssynchrony can improve heart failure in cases of dilated cardiomyopathy (DCMP) with preexcitation. Here, we report the first case of a child with DCMP and Wolff-Parkinson-White (WPW) syndrome treated with amiodarone and radiofrequency catheter ablation (RFCA) in Korea. A 7-year-old boy, who suffered from DCMP and WPW syndrome, showed improved left ventricular function and clinical functional class after treatment with amiodarone to eliminate preexcitation. QRS duration and left ventricular ejection fraction (LVEF) were inversely correlated with amiodarone dosage. After confirming the reduction of preexcitation effects in DCMP, successful RFCA of the right anterior AP resulted in LVEF improvement, along with the disappearance of preexcitation. Our findings suggest that ventricular dyssynchrony, caused by preexcitation in DCMP with WPW syndrome, can worsen ventricular function and amiodarone, as well as RFCA, which should be considered as a treatment option, even in young children. PMID:23407697

  7. Heat Sink Effect on Tumor Ablation Characteristics as Observed in Monopolar Radiofrequency, Bipolar Radiofrequency, and Microwave, Using Ex Vivo Calf Liver Model

    Science.gov (United States)

    Pillai, Krishna; Akhter, Javid; Chua, Terence C.; Shehata, Mena; Alzahrani, Nayef; Al-Alem, Issan; Morris, David L.

    2015-01-01

    Abstract Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices. With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored. With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres. Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected. Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5. MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink. PMID:25738477

  8. Year-Round Irrigation Schedule for a Tomato–Maize Rotation System in Reservoir-Based Irrigation Schemes in Ghana

    Directory of Open Access Journals (Sweden)

    Ephraim Sekyi-Annan

    2018-05-01

    Full Text Available Improving irrigation management in semi-arid regions of Sub-Saharan Africa is crucial to respond to increasing variability in rainfall and overcome deficits in current irrigation schemes. In small-scale and medium-scale reservoir-based irrigation schemes in the Upper East region of Ghana, we explored options for improving the traditional, dry season irrigation practices and assessed the potential for supplemental irrigation in the rainy season. The AquaCrop model was used to (i assess current water management in the typical tomato-maize rotational system; (ii develop an improved irrigation schedule for dry season cultivation of tomato; and (iii determine the requirement for supplemental irrigation of maize in the rainy season under different climate scenarios. The improved irrigation schedule for dry season tomato cultivation would result in a water saving of 130–1325 mm compared to traditional irrigation practices, accompanied by approximately a 4–14% increase in tomato yield. The supplemental irrigation of maize would require 107–126 mm of water in periods of low rainfall and frequent dry spells, and 88–105 mm in periods of high rainfall and rare dry spells. Therefore, year-round irrigated crop production may be feasible, using water saved during dry season tomato cultivation for supplemental irrigation of maize in the rainy season.

  9. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  10. Occupational exposure to radiofrequency fields in antenna towers

    International Nuclear Information System (INIS)

    Alanko, T.; Hietanen, M.

    2007-01-01

    Exposure of workers to radiofrequency fields was assessed in two medium-sized antenna towers. Towers had transmitting antennas from different networks, e.g. mobile phone networks, radio and digital TV sub-stations and amateur radio. The levels of radiofrequency fields were measured close to the ladders of the towers. All measured values were below ICNIRP occupational reference levels. (authors)

  11. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    Science.gov (United States)

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  12. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  13. Catheter-Related Sepsis Due to Rhodotorula glutinis

    Science.gov (United States)

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed catheter 17 days after initiation of fluconazole therapy exhibited high-level resistance to fluconazole (MICs, >256 μg/ml). These three isolates were found to belong to a single clone on the basis of identical antibiotypes determined by the E test (PDM Epsilometer; AB Biodisk, Solna, Sweden) and biotypes determined by API ID32 C (bioMerieux, Marcy I'Etoile, France) and their identical random amplified polymorphic DNA patterns. PMID:12574300

  14. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    Science.gov (United States)

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  15. Number and location of drainage catheter side holes: in vitro evaluation.

    Science.gov (United States)

    Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B

    2015-09-01

    To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Real-time optical monitoring of permanent lesion progression in radiofrequency ablated cardiac tissue (Conference Presentation)

    Science.gov (United States)

    Singh-Moon, Rajinder P.; Hendon, Christine P.

    2016-02-01

    Despite considerable advances in guidance of radiofrequency ablation (RFA) therapies for atrial fibrillation, success rates have been hampered by an inability to intraoperatively characterize the extent of permanent injury. Insufficient lesions can elusively create transient conduction blockages that eventually reconduct. Prior studies suggest significantly greater met-myoglobin (Mmb) concentrations in the lesion core than those in the healthy myocardium and may serve as a marker for irreversible tissue damage. In this work, we present real-time monitoring of permanent injury through spectroscopic assessment of Mmb concentrations at the catheter tip. Atrial wedges (n=6) were excised from four fresh swine hearts and submerged under pulsatile flow of warm (37oC) phosphate buffered saline. A commercial RFA catheter inserted into a fiber optic sheath allowed for simultaneous measurement of tissue diffuse reflectance (DR) spectra (500-650nm) during application of RF energy. Optical measurements were continuously acquired before, during, and post-ablation, in addition to healthy neighboring tissue. Met-myoglobin, oxy-myoglobin, and deoxy-myoglobin concentrations were extracted from each spectrum using an inverse Monte Carlo method. Tissue injury was validated with Masson's trichrome and hematoxylin and eosin staining. Time courses revealed a rapid increase in tissue Mmb concentrations at the onset of RFA treatment and a gradual plateauing thereafter. Extracted Mmb concentrations were significantly greater post-ablation (p<0.0001) as compared to healthy tissue and correlated well with histological assessment of severe thermal tissue destruction. On going studies are aimed at integrating these findings with prior work on near infrared spectroscopic lesion depth assessment. These results support the use of spectroscopy-facilitated guidance of RFA therapies for real-time permanent injury estimation.

  17. Suprapubic catheter care

    Science.gov (United States)

    ... going back into your bladder. Try not to disconnect the catheter more than you need to. Keeping ... Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of ...

  18. Radiofrequency ablation of liver tumors (II): clinical application and outcomes.

    Science.gov (United States)

    Vanagas, Tomas; Gulbinas, Antanas; Pundzius, Juozas; Barauskas, Giedrius

    2010-01-01

    Radiofrequency ablation is one of the alternatives in the management of liver tumors, especially in patients who are not candidates for surgery. The aim of this article is to review applicability of radiofrequency ablation achieving complete tumor destruction, utility of imaging techniques for patients' follow-up, indications for local ablative procedures, procedure-associated morbidity and mortality, and long-term results in patients with different tumors. The success of local thermal ablation consists in creating adequate volumes of tissue destruction with adequate "clear margin," depending on improved delivery of radiofrequency energy and modulated tissue biophysiology. Different volumes of coagulation necrosis are achieved applying different types of electrodes, pulsing energy sources, utilizing sophisticated ablation schemes. Some additional methods are used to increase the overall deposition of energy through alterations in tissue electrical conductivity, to improve heat retention within the tissue, and to modulate tolerance of tumor tissue to hyperthermia. Contrast-enhanced computed tomography, magnetic resonance imaging, ultrasound or positron emission tomography are applied to control the effectiveness of radiofrequency ablation. The long-term results of radiofrequency ablation are controversial.

  19. 77 FR 43535 - Grantee Codes for Certified Radiofrequency Equipment

    Science.gov (United States)

    2012-07-25

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 2 [FCC 12-60] Grantee Codes for Certified Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: This document... authorization program for radiofrequency (RF) devices under part 2 of its rules. This program is one of the...

  20. Irrigation water sources and irrigation application methods used by U.S. plant nursery producers

    Science.gov (United States)

    Paudel, Krishna P.; Pandit, Mahesh; Hinson, Roger

    2016-02-01

    We examine irrigation water sources and irrigation methods used by U.S. nursery plant producers using nested multinomial fractional regression models. We use data collected from the National Nursery Survey (2009) to identify effects of different firm and sales characteristics on the fraction of water sources and irrigation methods used. We find that regions, sales of plants types, farm income, and farm age have significant roles in what water source is used. Given the fraction of alternative water sources used, results indicated that use of computer, annual sales, region, and the number of IPM practices adopted play an important role in the choice of irrigation method. Based on the findings from this study, government can provide subsidies to nursery producers in water deficit regions to adopt drip irrigation method or use recycled water or combination of both. Additionally, encouraging farmers to adopt IPM may enhance the use of drip irrigation and recycled water in nursery plant production.

  1. Wireless sensor networks for irrigation management

    Science.gov (United States)

    Sustaining an adequate food supply for the world's population will require advancements in irrigation technology and improved irrigation management. Site-specific irrigation and automatic irrigation scheduling are examples of strategies to deal with declining arable land and limited fresh water reso...

  2. Clinical application and developmental trend of radiofrequency ablation technology

    International Nuclear Information System (INIS)

    Chen Dongfeng

    2009-01-01

    For recent two decades, radiofrequency ablation technology has made great progress in the field of the treatment for neoplasm. At the very beginning, radiofrequency ablation was adopted in treating the hepatic carcinoma, and since then it has been gradually practiced in treating malignancies of lung, bone, kidney, breast, prostate and other solid tumors. Statistical report of the year 2008 has indicated that in the aspect of similar therapeutic measures radiofrequency ablation therapy for tumors holds a 9% market share. Moreover, in the coming years the clinical use of this kind of therapy for tumors will be steadily increasing by 13% every year. (authors)

  3. Scintigraphic assessment of colostomy irrigation.

    Science.gov (United States)

    Christensen, P.; Olsen, N.; Krogh, K.; Laurberg, S.

    2002-09-01

    OBJECTIVE: This study aims to evaluate colonic transport following colostomy irrigation with a new scintigraphic technique. MATERIALS AND METHODS: To label the bowel contents 19 patients (11 uncomplicated colostomy irrigation, 8 complicated colostomy irrigation) took 111In-labelled polystyrene pellets one and two days before investigation. 99mTc-DTPA was mixed with the irrigation fluid to assess its extent within the bowel. Scintigraphy was performed before and after a standardized washout procedure. The colon was divided into three segments 1: the caecum andascending colon; 2: the transverse colon; 3: the descending and sigmoid colon. Assuming ordered evacuation of the colon, the contribution of each colonic segment to the total evacuation was expressed as a percentage of the original segmental counts. These were added to reach a total defaecation score (range: 0-300). RESULTS: In uncomplicated colostomy irrigation, the median defaecation score was 235 (range: 145-289) corresponding to complete evacuation of the descending and transverse colon and 35% evacuation of the caecum/ascending colon. In complicated colostomy irrigation it was possible to distinguish specific emptying patterns. The retained irrigation fluid reached the caecum in all but one patient. CONCLUSION: Scintigraphy can be used to evaluate colonic emptying following colostomy irrigation.

  4. Modeling irrigation behavior in groundwater systems

    Science.gov (United States)

    Foster, Timothy; Brozović, Nicholas; Butler, Adrian P.

    2014-08-01

    Integrated hydro-economic models have been widely applied to water management problems in regions of intensive groundwater-fed irrigation. However, policy interpretations may be limited as most existing models do not explicitly consider two important aspects of observed irrigation decision making, namely the limits on instantaneous irrigation rates imposed by well yield and the intraseasonal structure of irrigation planning. We develop a new modeling approach for determining irrigation demand that is based on observed farmer behavior and captures the impacts on production and water use of both well yield and climate. Through a case study of irrigated corn production in the Texas High Plains region of the United States we predict optimal irrigation strategies under variable levels of groundwater supply, and assess the limits of existing models for predicting land and groundwater use decisions by farmers. Our results show that irrigation behavior exhibits complex nonlinear responses to changes in groundwater availability. Declining well yields induce large reductions in the optimal size of irrigated area and irrigation use as constraints on instantaneous application rates limit the ability to maintain sufficient soil moisture to avoid negative impacts on crop yield. We demonstrate that this important behavioral response to limited groundwater availability is not captured by existing modeling approaches, which therefore may be unreliable predictors of irrigation demand, agricultural profitability, and resilience to climate change and aquifer depletion.

  5. Balloon-tipped flow-directed catheters

    International Nuclear Information System (INIS)

    Ganz, P.; Swan, H.J.C.; Ganz, W.

    1986-01-01

    Diagnostic catheterization of the right side of the heart with semirigid cardiac catheters requires fluoroscopic guidance and substantial skill. Abnormal positions of the heart chambers and of the great vessels associated with cardiac dilatation or with congenital malformation present difficulties even to experienced laboratory cardiologists. These problems have been largely overcome by the introduction of balloon tipped flow directed catheters, which allow for rapid and relatively safe catheterization of the pulmonary artery without fluoroscopy. It was through the application of these catheters in the intensive care unit that the many pitfalls in the clinical assessment of hemodynamic disturbances became apparent. Although S3 gallop sounds may be useful in the clinical recognition of chronic ventricular failure, their presence or absence has limited predictive value in estimating left ventricular filling pressure in myocardial infarction. Information derived from right heart catheterization is often pivotal in the evaluation of hemodynamic disorders, in directing treatment, and in monitoring the results of therapy in critically ill patients

  6. Translumbar aortography by catheter technique

    International Nuclear Information System (INIS)

    Hagen, B.; Honemeyer, U.; Meier-Duis, H.

    1982-01-01

    400 examinations performed during the last three years by TLA (only catheter technique) were subjected to critical analysis and studied particularly in respect to the rate of complications. We observed 13 complications (3.25%) of moderate severity, including 3 large hematomas (documented by CT), 3 paravasations and 7 dissections, but no fatal complication. Two (0.5%) of these complications had clinical evidence. The advantages of the catheter technique of TLA are described. Injections through rigid metal cannula should be avoided because of the high incidence of complications (mainly the increased risk of dissection). Downstream injection resulted in excellent visualization of peripheral occluding vascular disease. Upstream injection should be preferred to demonstrate the major abdominal arteries as well as supraceliac collateral circulation in the case of high Leriche syndrome. The low or intermediate puncture of the aorta is preferable to facilitate caudad direction of the catheter and to diminish the risk of damaging other vessels or puncturing an organ. (orig.) [de

  7. Assessment of Irrigation Water Quality and Suitability for Irrigation in ...

    African Journals Online (AJOL)

    A number of factors like geology, soil, effluents, sewage disposal and other environmental conditions in which the water stays or moves and interacts are among the factors that affect the quality of irrigation water. This study was conducted to determine the quality and suitability of different water sources for irrigation purpose ...

  8. Effect of irrigation on heavy metals content of wastewater irrigated ...

    African Journals Online (AJOL)

    There is an urgent need to educate farmers on the dangers of the presence of heavy metals in soils as well as the quality of irrigation water especially if it comes from tanning industries for increased crop production. Accordingly, soil and irrigation wastewater study was conducted to assess the concentrations of heavy ...

  9. Catheter-associated UTI

    Science.gov (United States)

    ... UTI; Health care-associated UTI; Catheter-associated bacteriuria; Hospital acquired-UTI Images Bladder catheterization, female Bladder catheterization, male References Calfee DP. Prevention and control of health care-associated infections. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  10. An assessment of colostomy irrigation.

    Science.gov (United States)

    Laucks, S S; Mazier, W P; Milsom, J W; Buffin, S E; Anderson, J M; Warwick, M K; Surrell, J A

    1988-04-01

    One hundred patients with permanent sigmoid colostomies were surveyed to determine their satisfaction and success with the "irrigation" technique of colostomy management. Most patients who irrigate their colostomies achieve continence. Odors and skin irritation are minimized. The irrigation method is economical, time efficient, and allows a reasonably liberal diet. It avoids bulky appliances and is safe. In appropriately selected patients, the irrigation technique is the method of choice for management of an end-sigmoid colostomy.

  11. Irrigation and Autocracy

    DEFF Research Database (Denmark)

    Bentzen, Jeanet Sinding; Kaarsen, Nicolai; Wingender, Asger Moll

    2017-01-01

    . We argue that the effect has historical origins: irrigation allowed landed elites in arid areas to monopolize water and arable land. This made elites more powerful and better able to oppose democratization. Consistent with this conjecture, we show that irrigation dependence predicts land inequality...

  12. Outcome of tunneled infusion catheters inserted via the right internal jugular vein

    International Nuclear Information System (INIS)

    Shin, Sung Wook; Do, Young Soo; Choo, Sung Wook; Yoo, Wi Kang; Choo, In Wook; Kim, Jae Hyung

    2003-01-01

    To assess the outcome of tunneled central venous catheter placement via the right internal jugular vein. Between June 2001 and May 2002, 670 consecutive Hickman catheters were placed in 654 patients via the right internal jugular vein. The procedural complications arising and follow-up data obtained from May to July 2002 were evaluated. The technical success rate for catheter placement was 99.9% (669/670). Procedural complications were limited to eight cases (1.2%), including three pneumothoraces, one early migration of the catheter, one clinically unimportant air embolism, one catheter injury, one catheter kinking and one primary malpositioning in the azygos vein. Catheter dwelling time ranged from 1 to 407 (mean 107.1) days. During the follow-up period, 416 catheter were removed for various reasons: treatment had ended (n=334), patients declined treatment or their drug regimen was changed (n=16), late complications arose (n=53), or other circumstances intervened (n=13). Late complications included 44 cases of catheter-related infection (6.6%), five of catheter migration (0.7%), two of catheter occlusion (0.3%), one of thrombophlebitis (0.15%), and one of catheter-related right atrial thrombosis (0.15%). Only one instance of symptomatic venous thrombosis or stenosis was noted, namely the one case of thrombophlebitis. Because the incidence of subsequent symptomatic venous thrombosis or stenosis is lower, the preferred route for tunneled central venous catheter placement is the right internal jugular vein

  13. A computational fluid dynamics simulation framework for ventricular catheter design optimization.

    Science.gov (United States)

    Weisenberg, Sofy H; TerMaath, Stephanie C; Barbier, Charlotte N; Hill, Judith C; Killeffer, James A

    2017-11-10

    OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter's small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter's fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter's design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter's inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using

  14. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].

    Science.gov (United States)

    Hellige, G

    1976-01-01

    The experimentally in vitro determined dynamic response characteristics of 38 catheter manometer systems were uniform in the worst case to 5 c.p.s. and optimally to 26 c.p.s. Accordingly, some systems are only satisfactory for ordinary pressure recording in cardiac rest, while better systems record dp/dt correct up to moderate inotropic stimulation of the heart. In the frequency range of uniform response (amplitude error less +/- 5%) the phase distortion is also negligible. In clinical application the investigator is often restricted to special type of cardiac catheter. In this case a low compliant transducer yields superior results. In all examined systems the combination with MSD 10 transducers is best, whereas the combination with P 23 Db transducers leads to minimal results. An inadequate system for recording ventricular pressure pulses leads in most cases to overestimations of dp/dtmax. The use of low frequency pass filters to attenuate higher frequency artefacts is, under clinical conditions, not suitable for extending the range of uniform frequency response. The dynamic response of 14 catheter manometer systems with two types of continuous self flush units was determined. The use of the P 37 flush unit in combination with small internal diameter catheters leads to serious error in ordinary pressure recording, due to amplitude distortion of the lower harmonics. The frequency response characteristics of the combination of an Intraflow flush system and MSD 10 transducer was similar to the non-flushing P 23 Db transducer feature.

  15. Level of Radiofrequency (RF) Radiations from GSM Base Stations ...

    African Journals Online (AJOL)

    Levels of radiofrequency radiations around two global systems for mobile communication (GSM) base stations located in the vicinity of a residential quarter and workplace complex were measured. The effects of the radiofrequency radiations on albino mice placed in exposure cages and located around the base stations ...

  16. STUDY ON MICROBIAL COMMUNITIES AND SOIL ORGANIC MATTER IN IRRIGATED AND NON-IRRIGATED VERTISOL FROM BOIANU

    Directory of Open Access Journals (Sweden)

    Sorina Dumitru

    2012-12-01

    Full Text Available Irrigation, when administered correctly, confers the producers the possibility to overcome drought effects and obtain higher yields, supplementing the quality of food for animals or human consumers. In the mean time, soil erosion, pathogens attack and nutrients or pesticides spreading can be prevented by an adequate management of irrigation water. As a consequence, soil microbial community structure, composition and activities, as well as the organic matter quality can be different from those in non-irrigated soil. Research have been carried out in order to assess changes in bacterial and fungal communities and activity in irrigated Vertisol from Boianu, as compared with non-irrigated. The paper presents the results concerning the taxonomical composition of bacterial and fungalmicroflora in the horizons of the two soil profiles, as well as the level of CO2 released by microorganisms. Chromatographic aspects of humus fractions were used to characterize the organic matter in irrigated and nonirrigated soil. Increased moisture and lowered temperature in Ap horizon of irrigated soil increased bacterial counts(18 x106 viable cells x g-1 dry soil and their metabolic activity expressed by carbon dioxide released (46.838mg CO2 x g-1 dry soil comparatively with non- irrigated soil. Fungal microflora was more abundant after 25-50cm under irrigation. Species diversity slightly increased under irrigation in both upper and lower part of soil profile. In irrigated soil, associations of species belonging to bacterial genera Pseudomonas and Bacillus were dominant in surface and white actinomycetes in the depth. Fungal consortia of Penicillium, Aspergillus and Fusarium dominated in both soil profiles.Irrigation induced changes in the quantity and quality of soil organic matter, as well as in the aspect of their migration pattern, as revealed on circular chromatograms.

  17. Radiofrequency ablation of osteoid osteomas: five years experience.

    Science.gov (United States)

    Papathanassiou, Zafiria G; Petsas, Theodore; Papachristou, Dionysios; Megas, Panagiotis

    2011-12-01

    The purpose of this study is to retrospectively evaluate the efficacy of radiofrequency ablation as a curative treatment method for benign bone tumours. Twenty-nine osteoid osteomas were treated with radiofrequency ablation. Primary success rate was 89.6% and total secondary success rate was 93.1%. Mean clinical follow-up period was 26.7 months (range: 6-63 months). Statistical analysis of 25 cases of osteoid osteomas with CT follow-up revealed that post-treatment re-ossification does not correlate with clinical outcome (p = 0.14) but is strongly correlated with long-term (> or = 12 months) CT follow-up (p = 0.014). Percutaneous radiofrequency ablation was found to be an effective and safe treatment for osteoid osteomas. CT findings cannot solely differentiate between treatment successes and failures.

  18. Interactions between radiofrequency signals and living organisms

    International Nuclear Information System (INIS)

    Boudin, F.; Hours, M.; Lacronique, J.F.; Conil, E.; Hadjem, A.; El Habachi, A.; Wiart, K.; Mann, S.; Kundi, M.; Marc-Vergnes, J.P.; Roosli, M.; Mohler, E.; Frei, P.; Davis, Ch.C.; Balzano, Q.; Ait-Aissa, S.; Billaudel, B.; Poulletier De Gannes, F.; Hurtier, A.; Haro, E.; Taxile, M.; Veyret, B.; Lagroye, I.; Ait-Aissa, S.; Poulletier De Gannes, F.; Athane, A.; Veyret, B.; Lagroye, I.; Yardin, C.; Perrin, A.; Freire, M.; Bachelet, Ch.; Collin, A.; Pla, S.; Debouzy, J.C.; Leveque, Ph.; Van Nierop, L.E.; Huss, A.; Roosli, M.; Egger, M.; Calvez, M.; Salomon, D.

    2010-01-01

    This dossier is composed of 13 articles dealing with the interactions between radio-frequencies and living organisms. It is an overview of various scientific approaches to the field and is of interest for all citizens as the use of mobile phones is widely spread. In the first article it is shown how a model has been built to assess the distribution of the whole body exposure of the population. The second article reviews the state of the art in personal exposure measurements at radio-frequencies. The third article shows that the knowledge of the mechanism of action by which exposure increases the risk of health hazards is necessary. The fourth article shows that individual neuro-psychic factors take a prominent but maybe not unique, part in electromagnetic hypersensitivity. The fifth article shows that no evidence was found to link health disturbances of electromagnetic hypersensitive individuals with radiofrequency exposure. The sixth article shows that the wireless phone is not an athermal hazard to the brain. The seventh article shows that the in utero and post-natal exposure to Wi-Fi does not damage the brains of young rats. The eighth article concludes that recent studies provide no convincing proof of deleterious effects of radiofrequency exposure on the integrity of the blood-brain barrier for specific absorption rates up to 6 W/kg. The ninth article shows that no co-genotoxic effect of radiofrequency was found at levels of exposure that did not induce heating. The tenth article confirms that industry-sponsored studies were least likely to report results suggesting effects. The last article shows that general practitioners are increasingly questioned by their patients about the issue of electromagnetic waves. (A.C.)

  19. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    Science.gov (United States)

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

  20. Percutaneous untying of a knot in a retained Swan-Ganz catheter

    International Nuclear Information System (INIS)

    Bhatti, Waqar A.; Sinha, Sankar; Rowlands, Peter

    2000-01-01

    A patient was referred to us with a tightly knotted Swan-Ganz catheter. The catheter could not be removed by conventional simple methods. We describe a minimally invasive means of removal of the catheter using an Amplatz gooseneck snare and an angioplasty balloon. This allowed the Catheter to be removed without trauma.

  1. Dialysis catheter-related septicaemia--focus on Staphylococcus aureus septicaemia

    DEFF Research Database (Denmark)

    Nielsen, J; Ladefoged, S D; Kolmos, H J

    1998-01-01

    BACKGROUND: Dialysis catheters are a common cause of nosocomial septicaemia in haemodialysis units usually due to staphylococci, of which Staphylococcus aureus is the most pathogenic. In this study, the epidemiology and pathogenesis of dialysis catheter-related infections were studied, and methods...... to infection were measured. After catheter insertion, all patients were screened for nasal carriage of S. aureus, and a culture was taken from the skin overlying the catheter insertion site. Once a week, cultures were taken from the insertion site and from the hub, and aerobic and anaerobic blood cultures were...... drawn from the catheter. If clinical signs of septicaemia occurred, peripheral blood cultures were also performed, when it was possible. RESULTS: The incidence of septicaemia was 49% (21/43) in patients, and 56% of all cases were caused by S. aureus. The mortality was 14% (3/21) and the incidence...

  2. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    Science.gov (United States)

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  3. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.

    Science.gov (United States)

    Cooper, M A; Fletter, P C; Zaszczurynski, P J; Damaser, M S

    2011-03-01

    Catheter systems are utilized to measure pressure for diagnosis of voiding dysfunction. In a clinical setting, patient movement and urodynamic pumps introduce hydrostatic and motion artifacts into measurements. Therefore, complete characterization of a catheter system includes its response to artifacts as well its frequency response. The objective of this study was to compare the response of two disposable clinical catheter systems: water-filled and air-charged, to controlled pressure signals to assess their similarities and differences in pressure transduction. We characterized frequency response using a transient step test, which exposed the catheters to a sudden change in pressure; and a sinusoidal frequency sweep test, which exposed the catheters to a sinusoidal pressure wave from 1 to 30 Hz. The response of the catheters to motion artifacts was tested using a vortex and the response to hydrostatic pressure changes was tested by moving the catheter tips to calibrated heights. Water-filled catheters acted as an underdamped system, resonating at 10.13 ± 1.03 Hz and attenuating signals at frequencies higher than 19 Hz. They demonstrated significant motion and hydrostatic artifacts. Air-charged catheters acted as an overdamped system and attenuated signals at frequencies higher than 3.02 ± 0.13 Hz. They demonstrated significantly less motion and hydrostatic artifacts than water-filled catheters. The transient step and frequency sweep tests gave comparable results. Air-charged and water-filled catheters respond to pressure changes in dramatically different ways. Knowledge of the characteristics of the pressure-measuring system is essential to finding the best match for a specific application. Copyright © 2011 Wiley-Liss, Inc.

  4. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  5. Are There Infinite Irrigation Trees?

    Science.gov (United States)

    Bernot, M.; Caselles, V.; Morel, J. M.

    2006-08-01

    In many natural or artificial flow systems, a fluid flow network succeeds in irrigating every point of a volume from a source. Examples are the blood vessels, the bronchial tree and many irrigation and draining systems. Such systems have raised recently a lot of interest and some attempts have been made to formalize their description, as a finite tree of tubes, and their scaling laws [25], [26]. In contrast, several mathematical models [5], [22], [10], propose an idealization of these irrigation trees, where a countable set of tubes irrigates any point of a volume with positive Lebesgue measure. There is no geometric obstruction to this infinitesimal model and general existence and structure theorems have been proved. As we show, there may instead be an energetic obstruction. Under Poiseuille law R(s) = s -2 for the resistance of tubes with section s, the dissipated power of a volume irrigating tree cannot be finite. In other terms, infinite irrigation trees seem to be impossible from the fluid mechanics viewpoint. This also implies that the usual principle analysis performed for the biological models needs not to impose a minimal size for the tubes of an irrigating tree; the existence of the minimal size can be proven from the only two obvious conditions for such irrigation trees, namely the Kirchhoff and Poiseuille laws.

  6. Embolization of brain arteriovenous malformations using tracker catheter

    International Nuclear Information System (INIS)

    Kim, Sun Yong; Son, Mi Young; Jang, Jae Chun; Hwang, Mi Soo; Park, Bok Hwan

    1990-01-01

    With the recent advance in micro catheters, steerable guide wires, balloons, embolic materials and digital subtraction angiography (DSA), as well as technical refinements in endovascular surgery, there has been a revolution in therapeutic strategies for cerebral arteriovenous malformations (AVMs). We have performed super selective angiography and embolization with Tracker micro catheter about 12 cases of brain AVMs for therapeutic and preoperative aims. This micro catheter and guide wire provided high selectivity of feeding artery, greater maneuverability and useful for deliver various embolus materials

  7. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    Science.gov (United States)

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  8. Reconfigurable radio-frequency arbitrary waveforms synthesized in a silicon photonic chip.

    Science.gov (United States)

    Wang, Jian; Shen, Hao; Fan, Li; Wu, Rui; Niu, Ben; Varghese, Leo T; Xuan, Yi; Leaird, Daniel E; Wang, Xi; Gan, Fuwan; Weiner, Andrew M; Qi, Minghao

    2015-01-12

    Photonic methods of radio-frequency waveform generation and processing can provide performance advantages and flexibility over electronic methods due to the ultrawide bandwidth offered by the optical carriers. However, bulk optics implementations suffer from the lack of integration and slow reconfiguration speed. Here we propose an architecture of integrated photonic radio-frequency generation and processing and implement it on a silicon chip fabricated in a semiconductor manufacturing foundry. Our device can generate programmable radio-frequency bursts or continuous waveforms with only the light source, electrical drives/controls and detectors being off-chip. It modulates an individual pulse in a radio-frequency burst within 4 ns, achieving a reconfiguration speed three orders of magnitude faster than thermal tuning. The on-chip optical delay elements offer an integrated approach to accurately manipulating individual radio-frequency waveform features without constraints set by the speed and timing jitter of electronics, and should find applications ranging from high-speed wireless to defence electronics.

  9. Fast beam radiofrequency spectroscopy

    International Nuclear Information System (INIS)

    Pipkin, F.M.

    1983-01-01

    The combination of a fast atom or ion beam derived from a small accelerator with radiofrequency spectroscopy methods provides a powerful method for measuring the fine structure of atomic and molecular systems. The fast beam makes possible measurements in which two separated oscillatory fields are used to obtain resonance lines whose widths are less than the natural line width due to the lifetimes of the states. The separated oscillatory field lines have, in addition, a number of features which make possible measurements with greater precision and less sensitivity to systematic errors. The fast beam also makes accessible multiple photon radiofrequency transitions whose line width is intrinsically narrower than that of the single photon transitions and which offer great potential for high precision measurements. This report focuses on the techniques and their promise. Recent measurements of the fine structure of H and He + are used as illustrations

  10. Potential In Vivo UVC Disinfection of Catheter Lumens: Estimation of the Doses Received by the Blood Flow Outside the Catheter Tip Hole

    DEFF Research Database (Denmark)

    Bak, Jimmy; Jørgensen, Thomas Martini; Helfmann, Jurgen

    2011-01-01

    hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate......We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exit...... by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2) ). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main...

  11. Prolonged PR interval predicts clinical recurrence of atrial fibrillation after catheter ablation.

    Science.gov (United States)

    Park, Junbeom; Kim, Tae-Hoon; Lee, Jihei Sara; Park, Jin Kyu; Uhm, Jae Sun; Joung, Boyoung; Lee, Moon Hyoung; Pak, Hui-Nam

    2014-10-07

    A prolonged PR interval is known to be a poor prognostic factor in cardiovascular disease. The aim of this study was to investigate the association between PR interval and clinical outcome in patients undergoing radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). We prospectively included 576 patients with AF (75.5% male, 57.8±11.6 years old, 68.8% paroxysmal AF) who underwent RFCA. We analyzed preprocedural sinus rhythm ECGs obtained in the absence of antiarrhythmic drug, and all enrolled patients were categorized into 4 groups based on the quartile values of the PR interval (166, 182, and 202 ms), and were analyzed according to the left atrium (LA) volume (CT; Computed tomography), LA voltage (NavX), and clinical outcome of AF ablation. Based on quartile value of PR interval, the highest quartile of PR interval (Q4; PR ≥202 ms) was oldest (PPR interval was a significant predictor of AF recurrence after RFCA of AF (HR=1.969, 95% CI 1.343 to 2.886, P=0.001). The PR interval was closely associated with advanced LA remodeling due to AF, and had a noninvasive significant predictive value of clinical recurrence of AF after RFCA. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  12. The effect of elastic modulus on ablation catheter contact area.

    Science.gov (United States)

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  13. Características construtivas e funcionais das agulhas de radiofrequência bipolares resfriadas para reduzir o sangramento nas ressecções hepáticas Construction of radiofrequency cold bipolar needles and its functional aspects to reduce the bleeding in hepatic resections

    Directory of Open Access Journals (Sweden)

    José Artur Sampaio

    2011-06-01

    cm in length, separated by a distance of 1.5 cm, and only distal 4 cm dissipate energy generated by a bipolar electrocautery. These needles are cooled by an internal cooling system for continuous flow of cold sterile distilled water at 0ºC, whose temperature is maintained through the presence of sterile distilled water ice. The operation is performed under general anesthesia and is not used central venous catheters during or after the procedure. The incisions may be right subcostal and median supra-umbilical. RESULTS: The inical use in liver resection showed an average 87 minutes operation time, average size of abdominal incision of 14 cm and 58 ml of blood loss during surgery. No patient in the inical group received transfusion of blood or blood products. CONCLUSION: The bipolar radiofrequency cooled needles are viable and reduce bleeding in liver resection.

  14. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    Energy Technology Data Exchange (ETDEWEB)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K [Medical University of South Carolina, Charleston, SC (United States)

    2016-06-15

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  15. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    International Nuclear Information System (INIS)

    Dise, J; McDonald, D; Ashenafi, M; Peng, J; Mart, C; Koch, N; Vanek, K

    2016-01-01

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels with similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed

  16. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  17. Percutaneous radiofrequency treatment for refractory anteromedial pain of osteoarthritic knees.

    Science.gov (United States)

    Ikeuchi, Masahiko; Ushida, Takahiro; Izumi, Masashi; Tani, Toshikazu

    2011-04-01

    Although severe knee osteoarthritis with refractory pain is commonly treated surgically, this is often not an option for patients with poor health status or unwillingness to undergo major surgery. We examined the efficacy of radiofrequency application to sensory nerves as a novel alternative treatment for refractory knee pain. This study was an open-label, nonrandomized, and controlled study. Patients complaining of refractory anteromedial knee pain associated with radiological osteoarthritis (moderate or severe) were included. They were assigned to one of two groups: those receiving radiofrequency thermocoagulation (N = 18) or those receiving nerve block (N = 17), depending on the time period that they were referred to the clinic. Radiofrequency current or local anesthetics was applied to the medial retinacular nerve and the infrapatellar branch of the saphenous nerve. Western Ontario McMaster Universities osteoarthritis index score, pain visual analog scale (VAS), and patient's global assessment were assessed with a minimum follow-up of 6 months.   Radiofrequency treatment significantly decreased knee pain as measured by VAS for 12 weeks compared with the control group. In terms of responders, more patients in the RF group responded to the treatment than in the control group. The differences were statistically significant at 4 weeks, 8 weeks, and 12 weeks in pain VAS. Eight patients (44%) treated with radiofrequency rated excellent or good but only three (18%) in the control group rated good, although the difference was not statistically significant. Some patients were able to benefit substantially from radiofrequency treatment. Even if its effective period is limited, radiofrequency application is a promising treatment to alleviate refractory anteromedial knee pain with osteoarthritis. Further experience and technical improvements are needed to establish its role in the management of knee osteoarthritis. Wiley Periodicals, Inc.

  18. Treatment of Refractory Idiopathic Supraorbital Neuralgia Using Percutaneous Pulsed Radiofrequency.

    Science.gov (United States)

    Luo, Fang; Lu, Jingjing; Ji, Nan

    2018-02-26

    No ideal therapeutic method currently exists for refractory idiopathic supraorbital neuralgia patients who do not respond to conservative therapy, including medications and nerve blocks. Pulsed radiofrequency is a neuromodulation technique that does not produce sequelae of nerve damage after treatment. However, the efficacy of percutaneous pulsed radiofrequency for the treatment of refractory idiopathic supraorbital neuralgia is still not clear. The purpose of our study was to evaluate the efficacy and safety of pulsed radiofrequency treatment of the supraorbital nerve for refractory supraorbital neuralgia patients. We prospectively investigated the long-term effects of ultrasound-guided percutaneous pulsed radiofrequency in the treatment of 22 refractory idiopathic supraorbital neuralgia patients. A reduction in the verbal pain numeric rating scale score of more than 50% was used as the standard of effectiveness. The effectiveness rates at different time points within 2 years were calculated. After a single pulsed radiofrequency treatment, the effectiveness rate at 1 and 3 months was 77%, and the rates at 6 months, 1 year, and 2 years were 73%, 64%, and 50%, respectively. Except for a small portion of patients (23%) who experienced mild upper eyelid ecchymosis that gradually disappeared after approximately 2 weeks, no obvious complications were observed. In conclusion, the results of our study demonstrate that for patients with refractory idiopathic supraorbital neuralgia, percutaneous pulsed radiofrequency may be an effective and safe treatment choice. © 2018 World Institute of Pain.

  19. Local land-atmosphere feedbacks limit irrigation demand

    Science.gov (United States)

    Decker, Mark; Ma, Shaoxiu; Pitman, Andy

    2017-05-01

    Irrigation is known to influence regional climate but most studies forecast and simulate irrigation with offline (i.e. land only) models. Using south eastern Australia as a test bed, we demonstrate that irrigation demand is fundamentally different between land only and land-atmosphere simulations. While irrigation only has a small impact on maximum temperature, the semi-arid environment experiences near surface moistening in coupled simulations over the irrigated regions, a feedback that is prevented in offline simulations. In land only simulations that neglect the local feedbacks, the simulated irrigation demand is 25% higher and the standard deviation of the mean irrigation rate is 60% smaller. These local-scale irrigation-driven feedbacks are not resolved in coarse-resolution climate models implying that use of these tools will overestimate irrigation demand. Future studies of irrigation demand must therefore account for the local land-atmosphere interactions by using coupled frameworks, at a spatial resolution that captures the key feedbacks.

  20. Percutaneous radiofrequency treatment of osteoid osteoma using cool-tip electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain)]. E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain); Ortiz, Eduardo [Departamento de Cirugia ortopedica, Fundacion Hospital Alcorcon, Madrid (Spain)

    2005-12-15

    Objectives: To report our experience with percutaneous cool-tip radiofrequency ablation of osteoid osteomas and to evaluate clinical outcome. Methods and material: Forty-one patients with clinically and radiologically suspected osteoid osteoma were seen over a 48-month period (27 males and 14 females with a mean age of 18.7 years; range 5-43 years). Thirty-eight patients were treated by computed tomography (CT)-guided percutaneous radiofrequency ablation. The procedure was performed under regional or general anaesthesia. After location of the nidus, a 14G-bone biopsy needle is introduced into the nidus. Sampling is performed with a 17G-bone biopsy needle using a coaxial technique. The radiofrequency needle with a 10 mm active tip (cool-tip) is inserted through the biopsy needle and is connected to the radiofrequency generator for 6-8 min. Results: Primary success was obtained in 37 patients (97%) with a 100% secondary success rate. All patients are currently pain-free. No major complications occurred. Patients could resume unrestricted normal activity within 24 h. Conclusions: Percutaneous radiofrequency ablation of osteoid osteomas is an efficient and safe method that can be considered the procedure of choice for most cases.

  1. Visualizing radiofrequency-skin interaction using multiphoton microscopy in vivo.

    Science.gov (United States)

    Tsai, Tsung-Hua; Lin, Sung-Jan; Lee, Woan-Ruoh; Wang, Chun-Chin; Hsu, Chih-Ting; Chu, Thomas; Dong, Chen-Yuan

    2012-02-01

    Redundant skin laxity is a major feature of aging. Recently, radiofrequency has been introduced for nonablative tissue tightening by volumetric heating of the deep dermis. Despite the wide range of application based on this therapy, the effect of this technique on tissue and the subsequent tissue remodeling have not been investigated in detail. Our objective is to evaluate the potential of non-linear optics, including multiphoton autofluorescence and second harmonic generation (SHG) microscopy, as a non-invasive imaging modality for the real-time study of radiofrequency-tissue interaction. Electro-optical synergy device (ELOS) was used as the radiofrequency source in this study. The back skin of nude mouse was irradiated with radiofrequency at different passes. We evaluated the effect on skin immediately and 1 month after treatment with multiphoton microscopy. Corresponding histology was performed for comparison. We found that SHG is negatively correlated to radiofrequency passes, which means that collagen structural disruption happens immediately after thermal damage. After 1 month of collagen remodeling, SHG signals increased above baseline, indicating that collagen regeneration has occurred. Our findings may explain mechanism of nonablative skin tightening and were supported by histological examinations. Our work showed that monitoring the dermal heating status of RF and following up the detailed process of tissue reaction can be imaged and quantified with multiphoton microscopy non-invasively in vivo. Copyright © 2011. Published by Elsevier Ireland Ltd.

  2. Intravascular catheter-related infection – current concepts

    African Journals Online (AJOL)

    2006-08-28

    Aug 28, 2006 ... prevented. ... blood from both the catheter and a peripheral site, may ... Given the important role of cutaneous microflora in the ... valvular heart disease (especially prosthetic valves) and ... be explained by high arterial flow around the catheter, ... vena cava or right atrium via the cephalic and basilar veins of ...

  3. Irrigation of steppe soils in the south of Russia: Problems and solutions (Analysis of Irrigation Practices in 1950-1990)

    Science.gov (United States)

    Minashina, N. G.

    2009-07-01

    Experience in irrigation of chernozems in the steppe zone of Russia for a period from 1950 to 1990 is analyzed. By the end of this period and in the subsequent years, the areas under irrigation reduced considerably, and the soil productivity worsened. This was caused by the improper design of irrigation systems, on the one hand, and by the low tolerance of chernozems toward increased moistening upon irrigation, on the other hand. The analysis of the factors and regimes of soil formation under irrigation conditions shows that irrigation-induced changes in the soil hydrology also lead to changes in the soil physicochemical, biochemical, and other properties. In particular, changes in the composition of exchangeable cations lead to the development of solonetzic process. In many areas, irrigation of chernozems was accompanied by the appearance of solonetzic, vertic, saline, and eroded soils. The development of soil degradation processes is described. In general, the deterioration of irrigated chernozems was related to the absence of adequate experience in irrigation of steppe soils, unskilled personnel, improper regime of irrigation, and excessively high rates of watering. In some cases, the poor quality of irrigation water resulted in the development of soil salinization and alkalization. To improve the situation, the training of personnel is necessary; the strategy of continuous irrigation should be replaced by the strategy of supplementary irrigation in the critical periods of crop development.

  4. Effect of radiofrequency on capacitance of low density plasma sheath

    International Nuclear Information System (INIS)

    Carneiro, L.T.; Cunha Rapozo, C. da

    1988-01-01

    It is shown that the influence of induced radiofrequency potential (V RF ) modifies the Bohm theory on ion saturation current, measured with Langmuir probes. The effect of radiofrequency potential on diode type plasma sheath resonance is also investigated. (M.C.K.)

  5. Tunnel unroofing effectiveness in chronic peritoneal catheter infection

    Directory of Open Access Journals (Sweden)

    Lorena Carranza

    2017-04-01

    Full Text Available Introduction: Chronic catheter infection usually involves external Dacron cuff colonization, without its removal, antibiotic treatment proved ineffective. Catheter unroofing technique has been described as an alternative to peritoneal catheter removal. Material and methods: We analyzed the data from 13 patients retrospectively. Evolution after unroofing was evaluated, considering as treatment failure the appearance of new infection in the hole, tunnel or peritonitis associated to the same germ. Results: Between 1997-2014 years, unroofing was performed on 13 patients. Mean age-rate: 46.2 (IC 95%: 35.9 years – 56.5 years male sex 9, 69.23%. Germs: staphylococcus 7, pseudomona 2, polymicrobial 1, negative culture 3. Nine patiens healed: 69.2%; there was no statistical association among sex, age, microbiological result, previous hemodialysis use, type of catheter, surgical technique or with the surgeon who performed the procedure (p≥ 0.05. Discussion: Catheter removal implies transient transference to hemodialysis and new replacement surgery, although there is few experience with this technique, it could be an acceptable alternative, enabling a group of patients to continue with PD treatment. Conclusion: Unroofing technique proved to be beneficial in 69.2% of the cases (9 patients independently of the type of germ present, representing an acceptable treatment which avoids catheter removal, enabling the procedure to continue, and decreasing the need to employ more aggressive therapies.

  6. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1994-12-15

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study.

  7. Balloon catheter dilatation in esophageal achalasia: long term follow-up

    International Nuclear Information System (INIS)

    Shin, Cheol Yong; Park, Hyun Mee; Kim, So Eun; Lee, Shin Hyung; Kim, Seung Hyeon; Lee, Chang Joon

    1994-01-01

    To evaluate the clinical efficacy of balloon catheter dilatation in the treatment of esophageal achalasia. Seven patients(three males and four females) with esopha-geal achalasia were treated with balloon catheter dilatation. Balloon catheters of variable sizes were used depending on patient's conditions. The patients were followed up over a period of 12-39 months. Balloon catheter dilatation in esophageal achalasia was successful in all patients without esophageal perforation. All patients were relieved from dysphagia. Recurrence was not found in 5 patients on long term follow-up study, but was seen in 2 patients after 18 and 21 months, respectively. Balloon catheter dilatation was a safe and effective method in the treatment of esophageal achalasia with low recurrence rate of 29% on follow-up study

  8. Innovating urinary catheter design: An introduction to the engineering challenge.

    Science.gov (United States)

    Murphy, Cathy

    2018-05-01

    Every day, people around the world rely on intermittent and indwelling urinary catheters to manage bladder dysfunction, but the potential or actual harm caused by these devices is well-recognised. Current catheter designs can cause urinary tract infection and septicaemia, bladder and urethral trauma and indwelling devices frequently become blocked. Furthermore, the devices can severely disrupt users' lives, limiting their daily activities and can be costly to manage for healthcare providers. Despite this, little significant design innovation has taken place in the last 80 years. In this article current catheter designs and their limitations are reviewed, common catheter-associated problems are outlined and areas of design ripe for improvement proposed. The potential to relieve the individual and economic burden of catheter use is high.

  9. The dialysis catheter and infectious peritonitis in intermittent peritoneal dialysis

    DEFF Research Database (Denmark)

    Kolmos, Hans Jørn; Hemmeløff Andersen, Karl Erik; Hansen, Lise

    1984-01-01

    118 episodes of infectious peritonitis registered among 156 patients treated with intermittent peritoneal dialysis over a 5-yr period were analysed with special reference to potential routes of infection associated with the dialysis catheter. Peritonitis was randomly distributed among the patients......, and the change of keeping free of peritonitis declined exponentially with time. The main factor determining the individual number of episodes was the total space of time, in which a patient had been wearing a dialysis catheter, whereas the number of catheter disconnections played no significant role. A relative...... preponderance of cases due to Enterobacteriaceae was noted within the first week after catheter implantation. In contrast with this, peritonitis with skin microorganisms was not associated with the implantation of catheters....

  10. Reversion of left ventricular systolic dysfunction and abnormal stress test: by catheter ablation, in a patient with Wolff-Parkinson-White syndrome from Para-Hisian Kent bundle.

    Science.gov (United States)

    Tu, Chung-Ming; Chu, Kai-Ming; Cheng, Cheng-Chung; Cheng, Shu-Mung; Lin, Wei-Shiang

    2010-01-01

    The diagnosis of Wolff-Parkinson-White syndrome is typically reserved for patients who experience ventricular pre-excitation and symptoms that are related to paroxysmal supraventricular tachycardia, such as chest pain, dyspnea, dizziness, palpitations, or syncope. Herein, we report the case of a 38-year-old woman who presented at our outpatient department because of exercise intolerance. Cardiac auscultation revealed a grade 2/6 pansystolic murmur over the left lower sternal border. Twelve-lead electrocardiography showed sinus rhythm at a rate of 76 beats/min, with a significant delta wave. Transthoracic echocardiography revealed abnormal left ventricular systolic function. The results of a thallium stress test were also abnormal. Coronary artery disease was suspected; however, coronary angiography yielded normal results. Electrophysiologic study revealed a para-Hisian Kent bundle and a dual atrioventricular nodal pathway. After radiofrequency catheter ablation was performed, the patient's left ventricular function improved and her symptoms disappeared. In Wolff-Parkinson-White syndrome, left ventricular systolic dyssynchrony can yield abnormal findings on echocardiography and thallium scanning--even in persons who have no cardiovascular risk factors. Physicians who are armed with this knowledge can avoid performing coronary angiography unnecessarily. Catheter ablation can reverse the dyssynchrony of the ventricle and improve the patient's symptoms.

  11. Irrigation management of sigmoid colostomy.

    Science.gov (United States)

    Jao, S W; Beart, R W; Wendorf, L J; Ilstrup, D M

    1985-08-01

    Questionnaires were sent to 270 patients who had undergone abdominoperineal resection and sigmoid colostomy at the Mayo Clinic, Rochester, Minn, during the ten years from 1972 to 1982; 223 patients returned their questionnaires with evaluable data. Sixty percent of the patients were continent with irrigation, and 22% were incontinent with irrigation. Eighteen percent had discontinued irrigation for various reasons. The proportion continent was higher in women, younger patients, and previously constipated patients. A poorly constructed colostomy may cause acute angle, parastoma hernia, stomal prolapse, or stenosis and thus be the cause of failure of irrigation.

  12. Catheter fracture of intravenous ports and its management.

    Science.gov (United States)

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P port type Arrow French (Fr.) 8.1 (P port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  13. Eye examinations of laser and radiofrequency radiation workers

    International Nuclear Information System (INIS)

    Hocking, B.

    1988-01-01

    There are a growing number of uses of lasers and radiofrequency radiation in industry. Because these radiations may lead to various ocular effects, examinations of the eye are required for laser and radiofrequency workers as part of safe working practices. Various issues concerning these examinations are raised for discussion including: handling personal data, placement criteria, data collection, quality control, control data, the load on service providers, and costs

  14. Two years experience with tunneled dialysis catheters in patients requiring haemodialysis

    International Nuclear Information System (INIS)

    Raheem, A.; Rana, A. I.; Ramzan, M.; Shah, R. A.; Mehmood, S. N.; Naseem, S.

    2014-01-01

    Objective: To look for survival rate and major reasons behind the failure of tunnelled dialysis catheters in patients on haemodialysis. Methods: The retrospective study was conducted at the Department of Interventional Radiology, Shifa International Hospital, Islamabad, and comprised records of 100 consecutive subjects from a list of patients in whom tunnelled cuffed catheters were placed from February 2009 to January 2011 and were followed up for two years. Data was collected on a proforma from the hospital database and medical records of patients. SPSS 19 was used for statistical analysis. Results: Of the total 122 catheters placed in 100 patients, 49(40.16%) were lost to follow-up. Of the remaining 73(59.83%) catheters, 38(52%) had achieved their desired function, while 35(48%) failed to achieve the target duration. Among the reasons of catheter failure, infection was the commonest at 13(37.14%) with infection rate of 0.24 per 1000 catheter days. According to Kaplan Meier analysis, catheter survival rates at 60, 90 and 180 days were 89%, 77% and 64% respectively. Mean effective duration of catheter was 129+-117 days. Conclusion: Tunnelled dialysis catheters can be safely used as vascular access till the maturation of fistula and may be an alternative to Arterio-Venous Fistula or graft for long-term vascular access if indicated. (author)

  15. An experimental study about efficacy of the drain catheters

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Bum Gyu; Nho, Joon Young; Woo, Hyo Cheol; Hwang, Woo Cheol; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Although percutaneous abscess drainage has become and accepted alternative from of therapy for selected patients with abscess, it is well known that there are several factors in the failure of adequate drainage such as pre- and post-procedural management, technique itself, various features of abscess, and selection and application of catheters. Among these factors, we made an experiment about drainage efficacy of commonly used various catheters with different viscosities of water-glycerin solution under the two different pressure gradients. The experimental values of flow rate were very lower than the calculated values. An efficacy of experimental value was 4-14%. Because the inner diameter of fittings and stopcocks was usually smaller than the inner diameter of catheters, these factors also affected the drain efficacy. Finally, we thought that it will be very helpful to the treatment of patient as well as to study about the catheter drainage, if the drain efficacy of individual catheters has been notified.

  16. Vessel bifurcation localization based on intraoperative three-dimensional ultrasound and catheter path for image-guided catheter intervention of oral cancers.

    Science.gov (United States)

    Luan, Kuan; Ohya, Takashi; Liao, Hongen; Kobayashi, Etsuko; Sakuma, Ichiro

    2013-03-01

    We present a method to localize intraoperative target vessel bifurcations under bones for ultrasound (US) image-guided catheter interventions. A catheter path is recorded to acquire skeletons for the target vessel bifurcations that cannot be imaged by intraoperative US. The catheter path is combined with the centerlines of the three-dimensional (3D) US image to construct a preliminary skeleton. Based on the preliminary skeleton, the orientations of target vessels are determined by registration with the preoperative image and the bifurcations were localized by computing the vessel length. An accurate intraoperative vessel skeleton is obtained for correcting the preoperative image to compensate for vessel deformation. A reality check of the proposed method was performed in a phantom experiment. Reasonable results were obtained. The in vivo experiment verified the clinical workflow of the proposed method in an in vivo environment. The accuracy of the centerline length of the vessel for localizing the target artery bifurcation was 2.4mm. These results suggest that the proposed method can allow the catheter tip to stop at the target artery bifurcations and enter into the target arteries. This method can be applied for virtual reality-enhanced image-guided catheter intervention of oral cancers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Bray–Liebhafsky oscillatory reaction in the radiofrequency electromagnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Stanisavljev, Dragomir R., E-mail: dragisa@ffh.bg.ac.rs [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia); Velikić, Zoran [Institute of Physics, University of Belgrade, Pregrevica 118, Zemun (Serbia); Veselinović, Dragan S.; Jacić, Nevena V.; Milenković, Maja C. [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia)

    2014-09-30

    Highlights: • Oscillatory Bray–Liebhafsky reaction is coupled with the radiofrequency radiation. • The effects of radiofrequency field on oscillatory parameters are investigated. • Radiofrequency power of up to the 0.2 W did not produced observable changes. • The explanation related with dissipative and capacitive effects is given. • Open the possibility of investigations of reactive effects on biological systems. - Abstract: Oscillatory Bray–Liebhafsky (BL) reaction is capacitively coupled with the electromagnetic radiation in the frequency range 60–110 MHz. Because of the specific reaction dynamics characterized by several characteristic parameters (induction period, period between chemical oscillations and their amplitude) it served as a good model system for the investigation of the effects of radiofrequent (RF) radiation. RF power of up to 0.2 W did not produce observable changes of the BL reaction parameters in the limit of the experiment reproductivity. Results indicate that, under the given experimental conditions, both dissipative and reactive properties of the solution are not considerably coupled with the RF electrical field.

  18. Assessing the changes of groundwater recharge / irrigation water use between SRI and traditional irrigation schemes in Central Taiwan

    Science.gov (United States)

    Chen, Shih-Kai; Jang, Cheng-Shin; Tsai, Cheng-Bin

    2015-04-01

    To respond to agricultural water shortage impacted by climate change without affecting rice yield in the future, the application of water-saving irrigation, such as SRI methodology, is considered to be adopted in rice-cultivation in Taiwan. However, the flooded paddy fields could be considered as an important source of groundwater recharge in Central Taiwan. The water-saving benefit of this new methodology and its impact on the reducing of groundwater recharge should be integrally assessed in this area. The objective of this study was to evaluate the changes of groundwater recharge/ irrigation water use between the SRI and traditional irrigation schemes (continuous irrigation, rotational irrigation). An experimental paddy field located in the proximal area of the Choushui River alluvial fan (the largest groundwater pumping region in Taiwan) was chosen as the study area. The 3-D finite element groundwater model (FEMWATER) with the variable boundary condition analog functions, was applied in simulating groundwater recharge process and amount under traditional irrigation schemes and SRI methodology. The use of effective rainfall was taken into account or not in different simulation scenarios for each irrigation scheme. The simulation results showed that there were no significant variations of infiltration rate in the use of effective rainfall or not, but the low soil moisture setting in deep soil layers resulted in higher infiltration rate. Taking the use of effective rainfall into account, the average infiltration rate for continuous irrigation, rotational irrigation, and SRI methodology in the first crop season of 2013 were 4.04 mm/day, 4.00 mm/day and 3.92 mm/day, respectively. The groundwater recharge amount of SRI methodology was slightly lower than those of traditional irrigation schemes, reducing 4% and 2% compared with continuous irrigation and rotational irrigation, respectively. The field irrigation requirement amount of SRI methodology was significantly

  19. CT-guided radiofrequency ablation of spinal osteoid osteomas with concomitant perineural and epidural irrigation for neuroprotection

    International Nuclear Information System (INIS)

    Klass, Darren; Marshall, Tom; Toms, Andoni

    2009-01-01

    Here we report our experience of a neuroprotective adaptation of the technique of CT-guided radiofrequency (RF) ablation of spinal osteoid osteomas. Over 9 years seven patients underwent eight CT-guided RF treatments for osteoid osteoma. CT-guided RF ablation was performed with general anaesthesia. The lesion was heated to 90 C for 2 min for two cycles by using a Cosman SMK TC-10 RF electrode. This was preceded by a bolus of room temperature sterile water (10 ml) injected through a 26G curved spinal needle into the exit foramen and adjacent epidural space for neuroprotection. The age of the patient, sex, lesion location, biopsy results and complications were recorded. All the biopsies (n = 7) demonstrated histological features of osteoid osteoma. All the procedures were technically successful. Clinical success was assessed up to 3 years post procedure. There was an 85% clinical success rate (6 of the 7 patients), with recurrence of a lesion at 6 months, necessitating a repeat procedure (successful). CT-guided percutaneous RF ablation of spinal osteoid osteoma preceded by bolus of sterile water, injected through a spinal needle into the exit foramen and adjacent epidural space for neuroprotection, is a safe and effective procedure. (orig.)

  20. Control of intravascular catheters using an array of active steering coils.

    Science.gov (United States)

    Gudino, N; Heilman, J A; Derakhshan, J J; Sunshine, J L; Duerk, J L; Griswold, M A

    2011-07-01

    To extend the concept of deflecting the tip of a catheter with the magnetic force created in an MRI system through the use of an array of independently controllable steering coils located in the catheter tip, and to present methods for visualization of the catheter and/or surrounding areas while the catheter is deflected. An array of steering coils made of 42-gauge wire was built over a 2.5 Fr (0.83 mm) fiber braided microcatheter. Two of the coils were 70 turn axial coils separated by 1 cm, and the third was a 15-turn square side coil that was 2 x 4 mm2. Each coil was driven independently by a pulse width modulation (PWM) current source controlled by a microprocessor that received commands from a MATLAB routine that dynamically set current amplitude and direction for each coil. The catheter was immersed in a water phantom containing 1% Gd-DTPA that was placed at the isocenter of a 1.5 T MRI scanner. Deflections of the catheter tip were measured from image-based data obtained with a real-time radio frequency (RF) spoiled gradient echo sequence (GRE). The small local magnetic fields generated by the steering coils were exploited to generate a hyperintense signal at the catheter tip by using a modified GRE sequence that did not include slice-select rewinding gradients. Imaging and excitation modes were implemented by synchronizing the excitation of the steering coil array with the scanner by ensuring that no current was driven through the coils during the data acquisition window; this allowed visualization of the surrounding tissue while not affecting the desired catheter position. Deflections as large as 2.5 cm were measured when exciting the steering coils sequentially with a 100 mA maximum current per coil. When exciting a single axial coil, the deflection was half this value with 30% higher current. A hyperintense catheter tip useful for catheter tracking was obtained by imaging with the modified GRE sequence. Clear visualization of the areas surrounding the

  1. Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.

    Science.gov (United States)

    Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E

    2009-05-01

    Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.

  2. Irrigation water management: Basic principles and applications

    OpenAIRE

    Ella, Victor B.

    2007-01-01

    This presentation defines the term, irrigation, as well as explains the common methods of irrigation in attempt to define the fundamental principles needed to wisely design an irrigation system. It outlines a typical drip irrigation set-up, and discusses management of an irrigation system, including water volume application suggestions. LTRA-5 (Agroforestry and Sustainable Vegetable Production)

  3. Irrigation-based livelihood challenges and opportunities : a gendered technology of irrigation development intervention in the Lower Moshi irrigation scheme Tanzania

    NARCIS (Netherlands)

    Kissawike, K.

    2008-01-01

    This thesis is a study of a modernised irrigation scheme in Tanzania. It aims to
    understand how irrigation and agricultural technologies have interacted with local
    society to transform production, paying particular attention to gender relations and
    changes for women farmers. The

  4. [Endovascular radiofrequency denervation of renal arteries as an innovation method of treatment of refractory arterial hypertension. First experience in Russia].

    Science.gov (United States)

    Danilov, N M; Matchin, Iu G; Chazova, I E

    2012-01-01

    Excessive activation of the sympathetic nervous system forms the basis of pathogenesis of essential arterial hypertension (AH). The present work was aimed at evaluating efficacy and safety of endovascular radiofrequency denervation of renal arteries in patients with AH refractory AH based on the initial first experience in with using this methodology in the Russian Federation. The interventions were carried out on December 14-15th, 2011 in the first five patients presenting with AH refractory to antihypertensive therapy consisting of three and more drugs in therapeutic doses, one of which was a diuretic. The selection criteria were systolic arterial pressure (SAP) ≥160 mm Hg or ≥150 mm Hg in the presence of type 2 diabetes mellitus. The obligatory conditions for selection were the preserved renal function [glomerular filtration rate (GFR) ≥45 ml/min] and the absence of the secondary form of AH. The procedure of denervation was performed in the conditions of roentgen-operating room using special Medtronic Ardian Simplicity Catheter System™. In all cases we managed to perform bilateral denervation of renal arteries with the radiofrequency effect in not less than 4 zones of each of vessels. Efficacy of each of the effect was registered with due regard for reaching certain temperature and values of impedance. The interventions were not accompanied by the development of any complications either in the area of manipulations or the site of puncture. Neither were there any complications from the side of the cardiovascular or excretory systems of the body. Diurnal monitoring of AP (DMAP) registered a significant decrease in SAP averagely from 174±12 to 145±10 mm Hg three days after the intervention. A persistent antihypertensive effect was confirmed by the DMAP findings one month after denervation - the SAP level averagely amounted to 131±6 mm Hg. Endovascular radiofrequency denervation of renal arteries is a safe and efficient method of treatment of AH resistant

  5. Comparative study of irrigation water use and groundwater recharge under various irrigation schemes in an agricultural region, central Taiwan

    Science.gov (United States)

    Chen, Shih-Kai; Jang, Cheng-Shin; Tsai, Cheng-Bin

    2016-04-01

    The risk of rice production has increased notably due to climate change in Taiwan. To respond to growing agricultural water shortage without affecting normal food production in the future, the application of water-saving irrigation will be a substantial resolution. However, the adoption of water-saving irrigation may result in the reducing of groundwater recharge because continuous flooding in the paddy fields could be regarded as an important source for groundwater recharge. The aim of this study was to evaluate the irrigation water-saving benefit and groundwater recharge deficit when adopting the System of Rice Intensification, known as SRI methodology, in the Choushui River alluvial fan (the largest groundwater pumping and the most important rice-cropping region in central Taiwan). The three-dimensional finite element groundwater model, FEMWATER, was applied to simulate the infiltration process and groundwater recharge under SRI methodology and traditional irrigation schemes including continuous irrigation, and rotational irrigation in two rice-crop periods with hydro-climatic data of 2013. The irrigation water use was then calculated by water balance. The results showed that groundwater recharge amount of SRI methodology was slightly lower than those of traditional irrigation schemes, reduced 3.6% and 1.6% in the first crop period, and reduced 3.2% and 1.6% in the second crop period, compared with continuous irrigation and rotational irrigation, respectively. However, the SRI methodology achieved notably water-saving benefit compared to the disadvantage of reducing the groundwater recharge amount. The field irrigation requirement amount of SRI methodology was significantly lower than those of traditional irrigation schemes, saving 37% and 20% of irrigation water in the first crop period, and saving 53% and 35% in the second crop period, compared with continuous irrigation and rotational irrigation, respectively. Therefore, the amount of groundwater pumping for

  6. Where Does the Irrigation Water Go? An Estimate of the Contribution of Irrigation to Precipitation Using MERRA

    Science.gov (United States)

    Wei, Jiangfeng; Dirmeyer, Paul A.; Wisser, Dominik; Bosilovich, Michael G.; Mocko, David M.

    2013-01-01

    Irrigation is an important human activity that may impact local and regional climate, but current climate model simulations and data assimilation systems generally do not explicitly include it. The European Centre for Medium-Range Weather Forecasts (ECMWF) Interim Re-Analysis (ERA-Interim) shows more irrigation signal in surface evapotranspiration (ET) than the Modern-Era Retrospective Analysis for Research and Applications (MERRA) because ERA-Interim adjusts soil moisture according to the observed surface temperature and humidity while MERRA has no explicit consideration of irrigation at the surface. But, when compared with the results from a hydrological model with detailed considerations of agriculture, the ET from both reanalyses show large deficiencies in capturing the impact of irrigation. Here, a back-trajectory method is used to estimate the contribution of irrigation to precipitation over local and surrounding regions, using MERRA with observation-based corrections and added irrigation-caused ET increase from the hydrological model. Results show substantial contributions of irrigation to precipitation over heavily irrigated regions in Asia, but the precipitation increase is much less than the ET increase over most areas, indicating that irrigation could lead to water deficits over these regions. For the same increase in ET, precipitation increases are larger over wetter areas where convection is more easily triggered, but the percentage increase in precipitation is similar for different areas. There are substantial regional differences in the patterns of irrigation impact, but, for all the studied regions, the highest percentage contribution to precipitation is over local land.

  7. Effective colostomy irrigation.

    Science.gov (United States)

    Mazier, W P; Dignan, R D; Capehart, R J; Smith, B G

    1976-06-01

    The ultimate goal of the cone method of colostomy irrigation is to return patients with colostomies to their former role in society with confidence in themselves to the extent that having a colostomy is not considered a handicap. The results have generally been excellent. We believe all patients with stomas should be afforded the opportunity to attempt colostomy irrigation.

  8. Potato yield and yield structure depending on irrigation

    Directory of Open Access Journals (Sweden)

    Milić Stanko

    2010-01-01

    Full Text Available In the agroclimatic conditions of the Vojvodina Province, the application of an economic water regime and modern technology is necessary for stable and intensive potato production. A two-year experiment on calcareous chernozem was carried out to determine how irrigation and different pre-irrigation soil moisture affect potato yield and distribution of tuber fraction in the potato yield. The block-design trial had four replicates and was adapted for sprinkler irrigation conditions. It included four treatments: irrigation with pre-irrigation moisture levels of 60 % of field water capacity (FC, irrigation with pre-irrigation moisture levels of 70 % (FC, irrigation with pre-irrigation moisture levels of 80% (FC, and a non-irrigated control treatment. Irrigation significantly increased the yield of potato, which increased from 37.27 % to 75.86 %. Under irrigation, the percentage of small fractions decreased in favour of the 55 mm one, or fractions above the 45-55 mm range. On average, irrigated treatments produced significantly more tubers than the conditions of natural water supply. .

  9. Percutaneous radiofrequency ablation for benign nodules of the thyroid gland

    International Nuclear Information System (INIS)

    Baek, Jung Hwan; Jeong, Hyun Jo; Kim, Yoon Suk; Kwak, Min Sook; Chang, Sun Hee; Rhim, Hyun Chul

    2005-01-01

    We wanted to evaluate the efficacy and safety of using ultrasound guided percutaneous radiofrequency ablation for the benign nodules of the thyroid gland. We studied 148 patients with benign thyroid nodules (200 total nodules) that were confirmed histopathologically, and we performed ultrasound guided radiofrequency ablation. The radiofrequency ablation was done 1 to 5 times per one nodule, and follow-up ultrasonography was performed one to nineteen months after the ablation procedures. The physical changes and the decrease of volume of the nodules were evaluated, and the complications related to radiofrequency ablation were observed. The mean initial nodule volume was 0.01-95.61 ml (mean; 6.83 ± SD of 10.63 ml) and the nodule volume after radiofrequency ablation was decreased to 0.00-46.56 ml (mean; 1.83 ± SD of 4.69 ml). The mean volume reduction rate was 73.2%. Reduction of more than 50% was noted in 90% of all cases. For 180 nodules (90%), the decrease was 50% or more, in 20 nodules (10%), the decrease was 49% or less. On gray-scale ultrasonogram obtained after ablation, the echogenicity of the nodules changed to darker, and on the doppler-sonogram, the vascular flow within the nodules disappeared in all cases. Most patients complained pain during or right after the procedure, but the pain was transient and subsided after medication. Two patients developed hoarseness that was improved in 1 week and 2 months, respectively. Sonoguided percutaneous radiofrequency ablation can be one of the treatments for benign nodules of the thyroid gland

  10. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  11. Knee cooled radiofrequency vs continuous radiofrequency for genicular neurotomy: preliminary experience - Crio-radiofrequenza vs radiofrequenza continua per neurotomia dei nervi genicolati: esperienza preliminare

    Directory of Open Access Journals (Sweden)

    Alfonso Papa

    2016-09-01

    Full Text Available Radiofrequency neurotomy of genicular nerves has been often used as an efficacious treatment option in all patients suffering from chronic osteoarthritis pain to provide long-term pain relief. After providing informed written consent, 80 patients with severe knee chronic osteoarthritis pain had been enrolled; patients had been divided into two groups (Group C, crioneurolysis, vs Group R, traditional radiofrequency, 40 patients for each group. Pain relief in C group was poorer and with shorter time in duration (median NRS reducing from 8 to 5. Radiofrequency can be considered as an effective, minimally invasive treat­ment for these kinds of conditions, and offers the benefit of being a fast procedure with long-term pain relief.

  12. Percutaneous catheter drainage of intrapulmonary fluid collection

    International Nuclear Information System (INIS)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H.

    1994-01-01

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment

  13. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  14. Paying attention to radiofrequency ablation therapy for neoplasms

    International Nuclear Information System (INIS)

    Wang Zhongming; Li Linsun

    2010-01-01

    Radiofrequency ablation is an effective treatment for malignant tumors. With the development of imaging technique, it has been widely used in treating different kinds of malignant tumors, such as liver cancer, lung cancer, kidney carcinoma, etc. Radiofrequency ablation has a lot of advantages. As a minimally-invasive, safe and effective treatment with less sufferings and fewer complications, this technique has attracted more and more attention of the experts both at home and abroad. (authors)

  15. Radiofrequency for the treatment of skin laxity: mith or truth*

    Science.gov (United States)

    de Araújo, Angélica Rodrigues; Soares, Viviane Pinheiro Campos; da Silva, Fernanda Souza; Moreira, Tatiane da Silva

    2015-01-01

    The nonablative radiofrequency is a procedure commonly used for the treatment of skin laxity from an increase in tissue temperature. The goal is to induce thermal damage to thus stimulate neocollagenesis in deep layers of the skin and subcutaneous tissue. However, many of these devices haven't been tested and their parameters are still not accepted by the scientific community. Because of this, it is necessary to review the literature regarding the physiological effects and parameters for application of radiofrequency and methodological quality and level of evidence of studies. A literature search was performed in MEDLINE, PEDro, SciELO, PubMed, LILACS and CAPES and experimental studies in humans, which used radiofrequency devices as treatment for facial or body laxity, were selected. The results showed that the main physiological effect is to stimulate collagen synthesis. There was no homogeneity between studies in relation to most of the parameters used and the methodological quality of studies and level of evidence for using radiofrequency are low. This fact complicates the determination of effective parameters for clinical use of this device in the treatment of skin laxity. The analyzed studies suggest that radiofrequency is effective, however the physiological mechanisms and the required parameters are not clear in the literature. PMID:26560216

  16. Performing drip irrigation by the farmer managed Seguia Khrichfa irrigation system, Morocco

    NARCIS (Netherlands)

    Kooij, van der S.

    2016-01-01

    Drip irrigation is represented in literature and agricultural policies as a modern and water saving technology. Because this technology is often associated with ‘modern’ agriculture and development, it seems out-of-place in ‘traditional’ farmer managed irrigation systems (FMIS). Thinking along

  17. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello [IRCCS Policlinico San Matteo Foundation, Pavia (Italy)

    2014-06-15

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  18. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    International Nuclear Information System (INIS)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello

    2014-01-01

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  19. Scheduling of Irrigation and Leaching Requirements

    Directory of Open Access Journals (Sweden)

    Amer Hassan Al-haddad

    2015-03-01

    Full Text Available Iraq depends mainly on Tigris and Euphrates Rivers to provide high percentage of agricultural water use for thousands years. At last years, Iraq is suffering from shortage in water resources due to global climate changes and unfair water politics of the neighboring countries, which affected the future of agriculture plans for irrigation, added to that the lack of developed systems of water management in the irrigation projects and improper allocation of irrigation water, which reduces water use efficiency and lead to losing irrigation water and decreasing in agricultural yield. This study aims at studying the usability of irrigation and leaching scheduling within the irrigating projects and putting a complete annual or seasonal irrigation program as a solution for the scarcity of irrigation water, the increase of irrigation efficiency, lessening the salinity in the projects and preparing an integral irrigation calendar through field measurements of soil physical properties and chemical for project selected and compared to the results of the irrigation scheduling and leaching with what is proposed by the designers. The process is accomplished by using a computer program which was designed by Water Resources Department at the University of Baghdad, with some modification to generalize it and made it applicable to various climatic zone and different soil types. Study area represented by large project located at the Tigris River, and this project was (Al-Amara irrigation project. Sufficient samples of project's soil were collected so as to identify soil physical and chemical properties and the salinity of soil and water as well as identifying the agrarian cycles virtually applied to this project. Finally, a comparison was conducted between the calculated water quantities and the suggested ones by the designers. The research results showed that using this kind of scheduling (previously prepared irrigation and leaching scheduling with its properties

  20. Multiple Coaxial Catheter System for Reliable Access in Interventional Stroke Therapy

    International Nuclear Information System (INIS)

    Kulcsar, Zsolt; Yilmaz, Hasan; Bonvin, Christophe; Lovblad, Karl O.; Ruefenacht, Daniel A.

    2010-01-01

    In some patients with acute cerebral vessel occlusion, navigating mechanical thrombectomy systems is difficult due to tortuous anatomy of the aortic arch, carotid arteries, or vertebral arteries. Our purpose was to describe a multiple coaxial catheter system used for mechanical revascularization that helps navigation and manipulations in tortuous vessels. A triple or quadruple coaxial catheter system was built in 28 consecutive cases presenting with acute ischemic stroke. All cases were treated by mechanical thrombectomy with the Penumbra System. In cases of unsuccessful thrombo-aspiration, additional thrombolysis or angioplasty with stent placement was used for improving recanalization. The catheter system consisted of an outermost 8-Fr and an intermediate 6-Fr guiding catheter, containing the inner Penumbra reperfusion catheters. The largest, 4.1-Fr, reperfusion catheter was navigated over a Prowler Select Plus microcatheter. The catheter system provided access to reach the cerebral lesions and provided stability for the mechanically demanding manipulations of thromboaspiration and stent navigation in all cases. Apart from their mechanical role, the specific parts of the system could also provide access to different types of interventions, like carotid stenting through the 8-Fr guiding catheter and intracranial stenting and thrombolysis through the Prowler Select Plus microcatheter. In this series, there were no complications related to the catheter system. In conclusion, building up a triple or quadruple coaxial system proved to be safe and efficient in our experience for the mechanical thrombectomy treatment of acute ischemic stroke.

  1. Biological degradation of chernozems under irrigation

    Directory of Open Access Journals (Sweden)

    Oksana Naydyonova

    2014-12-01

    Full Text Available We studied the changes in the state of microbial cenosis of Ukraine’s chernozems under irrigation. Considerable part of Ukraine’s chernozems is located in the areas where humidification is insufficient and unstable. Irrigation is a soil-reclamation measure for chernozems of Ukrainian Forest-steppe and Steppe which enables getting the assured yield, especially vegetable and fodder crops. At the same time, irrigation is a powerful anthropogenic factor that affects the soil, causes a significant transformation of many of its properties and regimes including biological ones. Often these changes are negative. The purpose of our investigation was to identify changes in the state of microbial cenoses of chernozem soils under irrigation which depend on such factors as the quality of irrigation water, the duration and intensity of irrigation, the initial properties of soil, the structure of crop rotation, usage of fertilizing systems and agroameliorative techniques. We identified direction and evaluated a degree of changes in biological properties of chernozems under influence of irrigation in different agro-irrigational and soil-climatic conditions. In the long-term stationary field experiments we identified the following biological indices of irrigated soils and their non-irrigated analogues: a number of microorganisms which belong to main ecological-trophic groups, activity of soil enzymes (dehydrogenase, invertase, phenol oxidase, soil phytotoxic activity, cellulose destroying capacity of soil, indices of oligotrophy and mineralization, summary biological index (SBI and index of biological degradation (BDI. Results of researches showed that irrigation unbalanced the soil ecosystem and stipulated the forming of microbial cenosis with new parameters. Long-term intensive irrigation of typical chernozem (Kharkiv Region with fresh water under condition of 4-fields vegetable crop rotation led to the degradation changes of its microbial cenosis such as

  2. Irrigation Analysis Based on Long-Term Weather Data

    Directory of Open Access Journals (Sweden)

    James R. Mahan

    2016-08-01

    Full Text Available Irrigation management is based upon delivery of water to a crop in the correct amount and time, and the crop’s water need is determined by calculating evapotranspiration (ET using weather data. In 1994, an ET-network was established in the Texas High Plains to manage irrigation on a regional scale. Though producers used the ET-network, by 2010 public access was discontinued. Why did producers allow a valuable irrigation-management tool to be eliminated? Our objective was to analyze the effect of declining well capacities on the usefulness of cotton ET (ETc for irrigation. Thirty years (1975–2004 of daily ETc data were used to compare irrigation demand vs. irrigation responses at four locations, analyzed for multiple years and range of well capacities for three irrigation-intervals. Results indicated that when well capacities declined to the point that over-irrigation was not possible, the lower well capacities reduced the value of ETc in terms of the number of irrigations and total amount of water applied. At well capacities <1514 L·min−1 the fraction of irrigations for which ETc information was used to determine the irrigation amount was <35% across years and irrigation intervals. The value of an ETc-based irrigation may fall into disuse when irrigation-water supplies decline.

  3. Septic Thrombophlebitis of the Cephalic Vein Caused by a Peripherally Inserted Venous Catheter

    Directory of Open Access Journals (Sweden)

    M Mirmohammadsadeghi

    2005-07-01

    Full Text Available Septic thrombophlebitis of a vein is a rare but life-threatening complication of an intravascular (IV catheter placed percutaneously in the veins. Most published clinical experiences with IV catheters, mainly in the outpatient settings, have reported very low rates of catheter-related bloodstream infection compared to rates with central venous catheters placed in a subclavian or internal jugular vein. Most of the complications reported with IV catheters have been non-infectious, particularly sterile phlebitis or thrombosis. We report a case of cephalic vein suppurative thrombophlebitis from an intravascular catheter and offer guidelines for diagnosis and management of this complication. Key words: Septic thrombophlebitis, Intravascular catheter, Suppurative thrombophlebitis

  4. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    International Nuclear Information System (INIS)

    Park, Jee Won; Jo, Jung Hyun; Park, Byeong Ho

    2007-01-01

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach

  5. The biological effects of quadripolar radiofrequency sequential application: a human experimental study.

    Science.gov (United States)

    Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-10-01

    An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening.

  6. One-year results of the use of endovenous radiofrequency ablation utilising an optimised radiofrequency-induced thermotherapy protocol for the treatment of truncal superficial venous reflux.

    Science.gov (United States)

    Badham, George E; Dos Santos, Scott J; Lloyd, Lucinda Ba; Holdstock, Judy M; Whiteley, Mark S

    2018-06-01

    Background In previous in vitro and ex vivo studies, we have shown increased thermal spread can be achieved with radiofrequency-induced thermotherapy when using a low power and slower, discontinuous pullback. We aimed to determine the clinical success rate of radiofrequency-induced thermotherapy using this optimised protocol for the treatment of superficial venous reflux in truncal veins. Methods Sixty-three patients were treated with radiofrequency-induced thermotherapy using the optimised protocol and were followed up after one year (mean 16.3 months). Thirty-five patients returned for audit, giving a response rate of 56%. Duplex ultrasonography was employed to check for truncal reflux and compared to initial scans. Results In the 35 patients studied, there were 48 legs, with 64 truncal veins treated by radiofrequency-induced thermotherapy (34 great saphenous, 15 small saphenous and 15 anterior accessory saphenous veins). One year post-treatment, complete closure of all previously refluxing truncal veins was demonstrated on ultrasound, giving a success rate of 100%. Conclusions Using a previously reported optimised, low power/slow pullback radiofrequency-induced thermotherapy protocol, we have shown it is possible to achieve a 100% ablation at one year. This compares favourably with results reported at one year post-procedure using the high power/fast pullback protocols that are currently recommended for this device.

  7. Evaluation of hydraulic performance of downstream-controlled Maira-PHLC irrigation canals under crop-based irrigation operations

    NARCIS (Netherlands)

    Munir, S.; Schultz, B.; Suryadi, F.X.; Bharati, L.

    2012-01-01

    Demand-based irrigation systems are operated according to crop water requirements. As crop water requirements remain variable throughout the growing season, the discharges in the canal also vary to meet demands. The irrigation system under study is a demand-based semi-automatic irrigation system,

  8. Role of sediment in the design and management of irrigation canals : Sunsari Morang Irrigation Scheme, Nepal

    NARCIS (Netherlands)

    Paudel, K.

    2010-01-01

    Sediment transport in irrigation canals The sediment transport aspect is a major factor in irrigation development as it determines to a large extent the sustainability of an irrigation scheme, particularly in case of unlined canals in alluvial soils. Investigations in this respect started since

  9. Foley Catheter versus Vaginal Misoprostol for Labour Induction

    Directory of Open Access Journals (Sweden)

    Nasreen Noor

    2015-01-01

    Full Text Available Objectives. To compare the efficacy and safety of intravaginal misoprostol with transcervical Foley catheter for labour induction. Material and Methods. One hundred and four women with term gestation, with Bishop score < 4, and with various indications for labour induction were randomly divided into two groups. In Group I, 25 μg of misoprostol tablet was placed intravaginally, 4 hourly up to maximum 6 doses. In Group II, Foley catheter 16F was placed through the internal os of the cervix under aseptic condition and then inflated with 50 cc of sterile saline. Statistical analysis was done using SPSS software. Results. The induction to delivery interval was 14.03 ± 7.61 hours versus 18.40 ± 8.02 hours (p<0.01. The rate of vaginal delivery was 76.7% versus 56.8% in misoprostol and transcervical Foley catheter group, respectively. Uterine hyperstimulation was more common with misoprostol. Neonatal outcome was similar in both the groups. Conclusion. Intravaginal misoprostol is associated with a shorter induction to delivery interval as compared to Foley’s catheter and it increases the rate of vaginal delivery in cases of unripe cervix at term. Transcervical Foley catheter is associated with a lower incidence of uterine hyperstimulation during labour.

  10. Electromagnetic field sources in radiofrequency

    International Nuclear Information System (INIS)

    Oliveira, C.; Sebastiao, D.; Ladeira, D.; Antunes, M.; Correia, L.M.

    2010-01-01

    In the scope of the monIT Project, several measurements were made of electromagnetic fields in Portugal. This paper presents an analysis of the sources operating in the radiofrequency range, resulting from 2429 measurements in 466 locations.

  11. Newer Root Canal Irrigants in Horizon: A Review

    Directory of Open Access Journals (Sweden)

    Sushma Jaju

    2011-01-01

    Full Text Available Sodium hypochloride is the most commonly used endodontic irrigant, despite limitations. None of the presently available root canal irrigants satisfy the requirements of ideal root canal irrigant. Newer root canal irrigants are studied for potential replacement of sodium hypochloride. This article reviews the potential irrigants with their advantages and limitations with their future in endodontic irrigation.

  12. The use of peridural catheter in the treatment of chronic malignant pain in the abdomen: Case report (peridural catheter in the treatment chronic pain

    Directory of Open Access Journals (Sweden)

    Palibrk Ivan

    2017-01-01

    Full Text Available Introduction: Chronic pain in the abdomen occurs as a consequence of malignancy in these parts of the body, surgical, of radiological and chemotherapy treatments. It may also be as a result of relapse of the basic process. Non-invasive therapy of oral and transdermal analgesic was successful for some time, where necessary applies and epidural catheter. Case Report: The patient had a diagnosis of chronic postoperative pain malignant etiology. He is already used transdermal fentanyl and Nonsteroidal Anti-Inflammatory Drugs, but without success (VAS score 8-10. We increased doses of analgesics, but without success. In order of pain therapy, peridural catheter placed in the level L3 - L4. 5 ml of a solution of 8 ml of 0.25% bupivacaine, 2 ml (100 micrograms of fentanyl and 10 ml of saline was administered every 6 hours through epidural catheter. The former chronic non-invasive treatment of pain did not stop. The first three to five days of pain relief was quite satisfactory in this way. Then the pain intensified but the peridural catheter had to be removed due to local infection. New peridural catheter was placed in the level L2 -L3. Then, 5 ml of the solution: of 8 ml 0,25% bupivacaine, 2 ml (100 micrograms of fentanyl and 10 ml of saline is administered through peridural catheter. Peridural catheter was total used for 45 days. We had a need for more and more frequently administering analgesics through a catheter during use. The patient was using transdermal fentanyl and Nonsteroidal Anti-Inflammatory Drugs, all the time. The patient soon died due to progression of the underlying disease. Conclusion: After long-term administration of opioids, it is necessary to change the type and route of administration of the drug to achieve the success of the therapy. In this case it was the use of analgesics and local anesthetics through the peridural catheter.

  13. Effects of renal denervation with a standard irrigated cardiac ablation catheter on blood pressure and renal function in patients with chronic kidney disease and resistant hypertension.

    Science.gov (United States)

    Kiuchi, Márcio Galindo; Maia, George Luiz Marques; de Queiroz Carreira, Maria Angela Magalhães; Kiuchi, Tetsuaki; Chen, Shaojie; Andrea, Bruno Rustum; Graciano, Miguel Luis; Lugon, Jocemir Ronaldo

    2013-07-01

    Evaluation of the safety and efficacy of renal denervation with a standard irrigated cardiac ablation catheter (SICAC) in chronic kidney disease (CKD) patients with refractory hypertension. Twenty-four patients were included and treated with a SICAC. Denervation was performed by a single operator following the standard technique. Patients included with CKD were on stages 2 (n = 16), 3 (n = 4), and 4 (n = 4). Data were obtained at baseline and monthly until 180th day of follow-up. Baseline values of blood pressure (mean ± SD) were 186 ± 19 mmHg/108 ± 13 mmHg in the office, and 151 ± 18 mmHg/92 ± 11 mmHg by 24 h ambulatory blood pressure monitoring (ABPM). Office blood pressure values at 180th day after the procedure were 135 ± 13 mmHg/88 ± 7 mmHg (P < 0.0001, for both comparisons). The mean ABPM decreased to 132 ± 15 mmHg/85 ± 11 mmHg at the 180th day after the procedure (P < 0.0001 for systolic and P = 0.0015 for diastolic). Estimated glomerular filtration (mean ± SD) increased from baseline (64.4 ± 23.9 mL/min/1.73 m(2)) to the 180th day (85.4 ± 34.9 mL/min/1.73 m(2), P < 0.0001) of follow-up. The median urine albumin:creatinine ratio decreased from baseline (48.5, IQR: 35.8-157.2 mg/g) to the 180th day after ablation (ACR = 15.7, IQR: 10.3-34.2 mg/g, P = 0.0017). No major complications were seen. The procedure using SICAC seemed to be feasible, effective, and safe resulting in a better control of BP, a short-term increase in estimated glomerular filtration rate, and reduced albuminuria. Although encouraging, our data are preliminary and need to be validated in the long term.

  14. Irrigation Water Management in Latin America

    Directory of Open Access Journals (Sweden)

    Aureo S de Oliveira

    2009-12-01

    Full Text Available Latin American countries show a great potential for expanding their irrigated areas. Irrigation is important for strengthening local and regional economy and for enhancing food security. The present paper aimed at providing a brief review on key aspects of irrigation management in Latin America. Poor irrigation management can have great impact on crop production and on environment while good management reduces the waste of soil and water and help farmers maximizing their profits. It was found that additional research is needed to allow a better understanding of crop water requirements under Latin American conditions as well as to provide farmers with local derived information for irrigation scheduling. The advantages of deficit irrigation practices and the present and future opportunities with the application of remote sensing tools for water management were also considered. It is clear that due to the importance of irrigated agriculture, collaborative work among Latin American researchers and institutions is of paramount importance to face the challenges imposed by a growing population, environment degradation, and competition in the global market.

  15. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    Science.gov (United States)

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  16. Infection and natural history of emergency department-placed central venous catheters.

    Science.gov (United States)

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  17. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  18. Detection of electrophysiology catheters in noisy fluoroscopy images

    NARCIS (Netherlands)

    Franken, E.M.; Rongen, P.M.J.; Almsick, van M.A.; Haar Romenij, ter B.M.

    2006-01-01

    Cardiac catheter ablation is a minimally invasive medical procedure to treat patients with heart rhythm disorders. It is useful to know the positions of the catheters and electrodes during the intervention, e.g. for the automatization of cardiac mapping. Our goal is therefore to develop a robust

  19. [Irrigants and intracanal medicaments in endodontics].

    Science.gov (United States)

    Zehnder, Matthias; Lehnert, Birgit; Schönenberger, Kathrin; Waltimo, Tuomas

    2003-01-01

    Modern, biologic root canal therapy should be performed with suitable irrigating solutions and intracanal medicaments. The goal of endodontic treatment is to free the treated tooth from infection and prevent reinfection as thoroughly as possible by means which do not put the organism at risk. In this review of the literature, an evidence-based concept for irrigation and medication of root canal systems is presented. Irrigants and medicaments are discussed with respect to their antimicrobial, tissue-dissolving and endotoxin-decontaminating capacity in relation to their systemic toxicity. Recent findings pertaining to interactions of root canal medicaments and irrigating solutions and their impact on a sound irrigating and medicating concept are discussed.

  20. Assessment of the radiofrequency ablation dynamics of esophageal tissue with optical coherence tomography

    Science.gov (United States)

    Lee, Hsiang-Chieh; Ahsen, Osman O.; Liu, Jonathan J.; Tsai, Tsung-Han; Huang, Qin; Mashimo, Hiroshi; Fujimoto, James G.

    2017-07-01

    Radiofrequency ablation (RFA) is widely used for the eradication of dysplasia and the treatment of early stage esophageal carcinoma in patients with Barrett's esophagus (BE). However, there are several factors, such as variation of BE epithelium (EP) thickness among individual patients and varying RFA catheter-tissue contact, which may compromise RFA efficacy. We used a high-speed optical coherence tomography (OCT) system to identify and monitor changes in the esophageal tissue architecture from RFA. Two different OCT imaging/RFA application protocols were performed using an ex vivo swine esophagus model: (1) post-RFA volumetric OCT imaging for quantitative analysis of the coagulum formation using RFA applications with different energy settings, and (2) M-mode OCT imaging for monitoring the dynamics of tissue architectural changes in real time during RFA application. Post-RFA volumetric OCT measurements showed an increase in the coagulum thickness with respect to the increasing RFA energies. Using a subset of the specimens, OCT measurements of coagulum and coagulum + residual EP thickness were shown to agree with histology, which accounted for specimen shrinkage during histological processing. In addition, we demonstrated the feasibility of OCT for real-time visualization of the architectural changes during RFA application with different energy settings. Results suggest feasibility of using OCT for RFA treatment planning and guidance.

  1. Rapid recovery from congestive heart failure following successful radiofrequency catheter ablation in a patient with late onset of Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Yodogawa, Kenji; Ono, Norihiko; Seino, Yoshihiko

    2012-01-01

    A 56-year-old man was admitted because of palpitations and dyspnea. A 12-lead electrocardiogram showed irregular wide QRS complex tachycardia with a slur at the initial portion of the QRS complex. He had preexisting long-standing persistent atrial fibrillation, but early excitation syndrome had never been noted. Chest X-ray showed heart enlargement and pulmonary congestion. He was diagnosed with late onset of Wolff-Parkinson-White syndrome, and congestive heart failure was probably caused by rapid ventricular response of atrial fibrillation through the accessory pathway. Emergency catheter ablation for the accessory pathway was undertaken, and heart failure was dramatically improved.

  2. Irrigation in dose assessments models

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla; Barkefors, Catarina [Studsvik RadWaste AB, Nykoeping (Sweden)

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  3. Irrigation in dose assessments models

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Barkefors, Catarina

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  4. Development of a force-reflecting robotic platform for cardiac catheter navigation.

    Science.gov (United States)

    Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung

    2010-11-01

    Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Sediment Transport Model for a Surface Irrigation System

    Directory of Open Access Journals (Sweden)

    Damodhara R. Mailapalli

    2013-01-01

    Full Text Available Controlling irrigation-induced soil erosion is one of the important issues of irrigation management and surface water impairment. Irrigation models are useful in managing the irrigation and the associated ill effects on agricultural environment. In this paper, a physically based surface irrigation model was developed to predict sediment transport in irrigated furrows by integrating an irrigation hydraulic model with a quasi-steady state sediment transport model to predict sediment load in furrow irrigation. The irrigation hydraulic model simulates flow in a furrow irrigation system using the analytically solved zero-inertial overland flow equations and 1D-Green-Ampt, 2D-Fok, and Kostiakov-Lewis infiltration equations. Performance of the sediment transport model was evaluated for bare and cropped furrow fields. The results indicated that the sediment transport model can predict the initial sediment rate adequately, but the simulated sediment rate was less accurate for the later part of the irrigation event. Sensitivity analysis of the parameters of the sediment module showed that the soil erodibility coefficient was the most influential parameter for determining sediment load in furrow irrigation. The developed modeling tool can be used as a water management tool for mitigating sediment loss from the surface irrigated fields.

  6. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  7. Auricular tachycardia: therapeutic and pathophysiologic news concepts: literature review and casuistic Service presentation

    International Nuclear Information System (INIS)

    Horta, J. de; Reyes, W.; Calleriza, F.; Pouso, J.; Besada, E.

    1998-01-01

    The auricular tachycardia are the supraventricular tachycardias whose origin mechanism and maintenance is located at level exclusively auricular. It show diagnostic and therapeutics difficulties.The inadequate handling can cause commitment of the ventricular function and to commit the predict vital.The pharmacological treatment, is more used is few effective.The ablation for catheter with radiofrequency is a new weapon transcendent therapy for the resolution of a significant group of these patients. A review of the concept of auricular tachycardias, it upgrades its classification and the mechanisms pathophysiologic.It describes the techniques of ablation for catheter in these arrhythmias and their results are revised in the literature. In the end it presents the casuistry of the Service in the treatment of the auricular tachycardias focal s,incision ales and atrial flutter by means of ablation for catheter with radiofrequency [es

  8. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    Science.gov (United States)

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.

  9. Bayesian Belief Networks Approach for Modeling Irrigation Behavior

    Science.gov (United States)

    Andriyas, S.; McKee, M.

    2012-12-01

    Canal operators need information to manage water deliveries to irrigators. Short-term irrigation demand forecasts can potentially valuable information for a canal operator who must manage an on-demand system. Such forecasts could be generated by using information about the decision-making processes of irrigators. Bayesian models of irrigation behavior can provide insight into the likely criteria which farmers use to make irrigation decisions. This paper develops a Bayesian belief network (BBN) to learn irrigation decision-making behavior of farmers and utilizes the resulting model to make forecasts of future irrigation decisions based on factor interaction and posterior probabilities. Models for studying irrigation behavior have been rarely explored in the past. The model discussed here was built from a combination of data about biotic, climatic, and edaphic conditions under which observed irrigation decisions were made. The paper includes a case study using data collected from the Canal B region of the Sevier River, near Delta, Utah. Alfalfa, barley and corn are the main crops of the location. The model has been tested with a portion of the data to affirm the model predictive capabilities. Irrigation rules were deduced in the process of learning and verified in the testing phase. It was found that most of the farmers used consistent rules throughout all years and across different types of crops. Soil moisture stress, which indicates the level of water available to the plant in the soil profile, was found to be one of the most significant likely driving forces for irrigation. Irrigations appeared to be triggered by a farmer's perception of soil stress, or by a perception of combined factors such as information about a neighbor irrigating or an apparent preference to irrigate on a weekend. Soil stress resulted in irrigation probabilities of 94.4% for alfalfa. With additional factors like weekend and irrigating when a neighbor irrigates, alfalfa irrigation

  10. Catheter Removal versus Retention in the Management of Catheter-Associated Enterococcal Bloodstream Infections

    Directory of Open Access Journals (Sweden)

    Jonas Marschall

    2013-01-01

    Full Text Available BACKGROUND: Enterococci are an important cause of central venous catheter (CVC-associated bloodstream infections (CA-BSI. It is unclear whether CVC removal is necessary to successfully manage enterococcal CA-BSI.

  11. Evaluation model development for sprinkler irrigation uniformity ...

    African Journals Online (AJOL)

    use

    Sprinkle and trickle irrigation. The. Blackburn Press, New Jersey, USA. Li JS, Rao MJ (1999). Evaluation method of sprinkler irrigation nonuniformity. Trans. CSAE. 15(4): 78-82. Lin Z, Merkley GP (2011). Relationships between common irrigation application uniformity indicators. Irrig Sci. Online First™, 27 January. 2011.

  12. Survey the Effects of Partial Root Zone Deficit Irrigation and Deficit Irrigation on Quantitative, Qualitative and Water Use Efficiency of Pomegranate

    Directory of Open Access Journals (Sweden)

    mohammad saeed tadaion

    2017-12-01

    Full Text Available Introduction: One of the latest efficient methods on increment of water use efficiency that confirmed by many scientists all over the world is deficit and alternative partial root zone deficit irrigation. In this experiment the effect of deficit and alternative partial root zone deficit irrigation on fruit yield, quality and water use efficiency of pomegranate (Punicagranatum (L. cv. Zarde-anar were investigatedin Arsenjan semi-arid region. Materials and Methods: The experiment was carried out in a constant plots and randomized complete block design (RCBD with four replicationsin five years.Treatmentswere 1- full flood irrigation (100 percent crop water requirement (T1 2- flood irrigation with 100 percent crop water requirement as alternate partial root-zone irrigation(every irrigation conducted on one side of tree (T2 3- flood irrigation with 50 percent crop water requirement as regular deficit irrigation (T3 4- full two-side drip irrigation(with regard to crop water requirement (eight drippers with twolit/hour flow by two different individual networks (T4 5- alternate partial root-zone drip irrigation with 100 percent crop water requirement (T5 6- regular deficit drip irrigation with 50 percent crop water requirement (T6 in every irrigation period. Each experimental treatment includes four trees and 96 similar twelve years old trees overall. Cultivation practice was conducted similarly on all of the trees. Results and Discussion: Results showed that the highest yield and water use efficiency based on statistical analysis belong to both PRD treatments i.e. alternate partial root-zone drip irrigation with 100 percent crop water requirement and alternate partial root-zone flood irrigation with 100 percent crop water requirement, respectively, that both of them decreased water requirement for irrigation up to 35 and 50 percent in comparison tocontrol. Application of partial root drying irrigation on both traditional flood irrigation and drip

  13. Cost-effectiveness of a central venous catheter care bundle.

    Directory of Open Access Journals (Sweden)

    Kate A Halton

    Full Text Available BACKGROUND: A bundled approach to central venous catheter care is currently being promoted as an effective way of preventing catheter-related bloodstream infection (CR-BSI. Consumables used in the bundled approach are relatively inexpensive which may lead to the conclusion that the bundle is cost-effective. However, this fails to consider the nontrivial costs of the monitoring and education activities required to implement the bundle, or that alternative strategies are available to prevent CR-BSI. We evaluated the cost-effectiveness of a bundle to prevent CR-BSI in Australian intensive care patients. METHODS AND FINDINGS: A Markov decision model was used to evaluate the cost-effectiveness of the bundle relative to remaining with current practice (a non-bundled approach to catheter care and uncoated catheters, or use of antimicrobial catheters. We assumed the bundle reduced relative risk of CR-BSI to 0.34. Given uncertainty about the cost of the bundle, threshold analyses were used to determine the maximum cost at which the bundle remained cost-effective relative to the other approaches to infection control. Sensitivity analyses explored how this threshold alters under different assumptions about the economic value placed on bed-days and health benefits gained by preventing infection. If clinicians are prepared to use antimicrobial catheters, the bundle is cost-effective if national 18-month implementation costs are below $1.1 million. If antimicrobial catheters are not an option the bundle must cost less than $4.3 million. If decision makers are only interested in obtaining cash-savings for the unit, and place no economic value on either the bed-days or the health benefits gained through preventing infection, these cost thresholds are reduced by two-thirds. CONCLUSIONS: A catheter care bundle has the potential to be cost-effective in the Australian intensive care setting. Rather than anticipating cash-savings from this intervention, decision

  14. Radiofrequency ablation of hepatic metastasis: Results of treatment in forty patients

    Directory of Open Access Journals (Sweden)

    Rath G

    2008-01-01

    Full Text Available Aim: To evaluate the local control of hepatic metastasis with radiofrequency ablation treatment. Materials and Methods: We did a retrospective analysis in 40 patients treated with radiofrequency ablation for hepatic metastasis. The tumors ablated included up to two metastatic liver lesions, with primaries in breast, gastrointestinal tract, cervix, etc. Radiofrequency ablation was performed under general anesthesia in all cases, using ultrasound guidance. Radionics Cool-Tip RF System was used to deliver the treatment. Results: The median age of patients treated was 49 years. There were 13 female and 27 male patients. The median tumor size ablated was 1.5 cm (0.75-4.0 cm. A total of 52 radiofrequency ablation cycles were delivered. Successful ablation was achieved in all patients with hepatic metastasis less than 3 cm in size. Pain was the most common complication seen (75%. One patients developed skin burns. At 2-year follow-up 7.5% of patients had locally recurrent disease. Conclusions: Radiofrequency ablation is a minimally invasive treatment modality. It can be useful in a select group of patients with solitary liver metastasis of less than 3 cm size.

  15. More than just a urinary catheter — Haemorrhage control by using a Foley catheter in a penetrating aortic root injury

    Directory of Open Access Journals (Sweden)

    Adel Elmoghrabi

    2016-08-01

    Full Text Available The prevalence of great vessel injuries in thoracic trauma is reported at 0.3–10%, predominantly due to a penetrating mechanism. Thoracic aortic injuries, more specifically those within proximity of the aortic root are challenging to manage and unceasing bleeding hampers adequate visualisation for performing repair. We report a case of a 31-year-old male that presented to the emergency department 1 h after sustaining a stab wound injury within proximity of the left upper sternal border. Vital signs were stable on presentation. Physical examination revealed a 1.5 cm laceration in the 3rd intercostal space. Chest X-ray revealed a small left pneumothorax, FAST scan was negative, and CT of the chest revealed left sided haemopneumothorax and haemopericardium. The patient was emergently transferred to the operating room where median thoracotomy was performed. A significant amount of bleeding was observed originating from a 1 cm laceration of the aortic root. Bleeding was controlled using a Foley catheter after unsuccessful attempts of digital compression, and the laceration was repaired using pledgeted sutures. Postoperative echocardiography and CT scan of the chest revealed normal cardiac functions with resolution of haemopericardium and haemopneumothorax, and the patient was discharged in a stable condition. High index of suspicion should be maintained for injury to the great vessels in patients with penetrating chest injuries, despite apparent haemodynamic stability. In this case, balloon tamponade using a Foley catheter served as a quick and simple technique that resulted in an almost bloodless field, facilitating adequate visualisation for definitive repair. Although the use of this technique has been previously described, this report serves as a reminder that a Foley catheter can be successfully used for balloon catheter tamponade in injuries to the aortic root. Keywords: Aortic root, Injury, Foley's catheter, Balloon catheter, Aorta

  16. 21 CFR 179.30 - Radiofrequency radiation for the heating of food, including microwave frequencies.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Radiofrequency radiation for the heating of food... PRODUCTION, PROCESSING AND HANDLING OF FOOD Radiation and Radiation Sources § 179.30 Radiofrequency radiation for the heating of food, including microwave frequencies. Radiofrequency radiation, including...

  17. Irrigation as an Historical Climate Forcing

    Science.gov (United States)

    Cook, Benjamin I.; Shukla, Sonali P.; Puma, Michael J.; Nazarenko, Larissa S.

    2014-01-01

    Irrigation is the single largest anthropogenic water use, a modification of the land surface that significantly affects surface energy budgets, the water cycle, and climate. Irrigation, however, is typically not included in standard historical general circulation model (GCM) simulations along with other anthropogenic and natural forcings. To investigate the importance of irrigation as an anthropogenic climate forcing, we conduct two 5-member ensemble GCM experiments. Both are setup identical to the historical forced (anthropogenic plus natural) scenario used in version 5 of the Coupled Model Intercomparison Project, but in one experiment we also add water to the land surface using a dataset of historically estimated irrigation rates. Irrigation has a negligible effect on the global average radiative balance at the top of the atmosphere, but causes significant cooling of global average surface air temperatures over land and dampens regional warming trends. This cooling is regionally focused and is especially strong in Western North America, the Mediterranean, the Middle East, and Asia. Irrigation enhances cloud cover and precipitation in these same regions, except for summer in parts of Monsoon Asia, where irrigation causes a reduction in monsoon season precipitation. Irrigation cools the surface, reducing upward fluxes of longwave radiation (increasing net longwave), and increases cloud cover, enhancing shortwave reflection (reducing net shortwave). The relative magnitude of these two processes causes regional increases (northern India) or decreases (Central Asia, China) in energy availability at the surface and top of the atmosphere. Despite these changes in net radiation, however, climate responses are due primarily to larger magnitude shifts in the Bowen ratio from sensible to latent heating. Irrigation impacts on temperature, precipitation, and other climate variables are regionally significant, even while other anthropogenic forcings (anthropogenic aerosols

  18. Needle catheter duodenostomy: a technique for duodenal alimentation of birds.

    Science.gov (United States)

    Goring, R L; Goldman, A; Kaufman, K J; Roberts, C; Quesenberry, K E; Kollias, G V

    1986-11-01

    A technique for duodenal alimentation (needle catheter duodenostomy) of birds was developed, using the domestic pigeon (Columba livia) as the experimental model. A needle catheter was inserted into the descending duodenum of 5 pigeons and was secured to the body wall and dorsum of each bird. A liquid diet was administered daily (in equal amounts of 0, 4, 8, 12, and 16 hours) for 14 days without adverse effects. On day 15, the catheters were removed, and the birds immediately resumed normal consumption of a pigeon ration and water diet. Although 4 of the 5 birds had minor weight loss, dietary alterations probably could be used on an individual basis to alleviate this problem. After oral alimentation was resumed, the 5 birds exceeded their initial body weight within 7 days. Four weeks after catheter removal, positive-contrast radiographic evaluations indicated that the duodenum of each pigeon appeared normal. Needle catheter duodenostomy was a viable method of alimentation in the domestic pigeon. This technique should be applicable for other avian species requiring bypass of the upper gastrointestinal tract proximal to the region of catheter insertion in the duodenum.

  19. A novel suture method to place and adjust peripheral nerve catheters

    DEFF Research Database (Denmark)

    Rothe, C.; Steen-Hansen, C.; Madsen, M. H.

    2015-01-01

    We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial...

  20. Total parenteral alimentation via indwelling umbilical catheters in the newborn period.

    Science.gov (United States)

    Hall, R T; Rhodes, P G

    1976-01-01

    Total parenteral alimentation (TPA) was delivered to 80 infants via indwelling umbilical artery and to 9 via indwelling umbilical venous catheters. The primary indication for catheter placement and maintenance was monitoring of arterial blood gases (umbilical venous catheter tip in left atrium) in a group of sick neonates requiring increased inspired oxygen or assisted ventilation. Results were compared with those from 23 infants who had tunnelled jugular catheters for a variety of chronic medical and surgical problems preventing gastric or intestinal feeding. A mean weight gain was achieved in both groups. Mortality and morbidity rates were similar in both groups. The most common complications were infection and thrombotic phenomena. Metabolic complications were few. It is concluded that infusing TPA solutions via indwelling umbilical catheters presents no greater risk than infusion via tunnelled jugular catheters, and provides a method for supplying adequate caloric intake for growth during the acute stage of illness. PMID:827978