WorldWideScience

Sample records for irreversible hydrocolloid impression

  1. Antimicrobial activity and properties of irreversible hydrocolloid impression materials incorporated with silver nanoparticles.

    Science.gov (United States)

    Ginjupalli, Kishore; Alla, Rama Krishna; Tellapragada, Chaitanya; Gupta, Lokendra; Upadhya Perampalli, Nagaraja

    2016-06-01

    Conventional spray and the immersion disinfection of irreversible hydrocolloid impression materials may lead to dimensional changes. The purpose of this in vitro study was to investigate the antimicrobial activity and properties of irreversible hydrocolloid impression materials incorporated with silver nanoparticles. The antimicrobial activity and properties of 2 commercially available irreversible hydrocolloid impression materials were evaluated after incorporating varying concentrations of silver nanoparticles. Antimicrobial activity was determined using the disk diffusion method. The gel strength, permanent deformation, flow, and gelation time were measured according to American Dental Association specification #18. Analysis of variance was used to identify the significant differences within and across the groups (α=.05). Adding silver nanoparticles to irreversible hydrocolloid impression materials resulted in superior antimicrobial activity without adversely affecting their properties. Adding silver nanoparticles to Zelgan significantly increased the gel strength compared with the control group, except at 5 wt%. However, the gel strength of Tropicalgin was unaffected except at 5 wt%. An increase in the permanent deformation was found with the incorporation of silver nanoparticles in both Zelgan and Tropicalgin. The flow of Zelgan increased with the incorporation of silver nanoparticles, whereas a decrease in the flow of Tropicalgin was observed at 1 wt% and 2 wt%. An increase in the gelation time of both Zelgan and Tropicalgin was observed with the incorporation of silver nanoparticles. Based on this in vitro study, silver nanoparticles can be incorporated into irreversible hydrocolloid impression materials as antimicrobial agents without adversely affecting their properties. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Antibacterial efficacy and effect of chlorhexidine mixed with irreversible hydrocolloid for dental impressions: a randomized controlled trial.

    Science.gov (United States)

    Cubas, Glória; Valentini, Fernanda; Camacho, Guilherme Brião; Leite, Fábio; Cenci, Maximiliano Sérgio; Pereira-Cenci, Tatiana

    2014-01-01

    This study aimed to evaluate whether chlorhexidine mixed with irreversible hydrocolloid powder decreases microbial contamination during impression taking without affecting the resulting casts. Twenty volunteers were randomly divided into two groups (n = 10) according to the liquid used for impression taking in conjunction with irreversible hydrocolloid: 0.12% chlorhexidine or water. Surface roughness and dimensional stability of the casts were evaluated. Chlorhexidine mixed with irreversible hydrocolloid decreased the percentage of microorganisms when compared with water (P impression quality.

  3. Effect of disinfection on irreversible hydrocolloid and alternative impression materials and the resultant gypsum casts.

    Science.gov (United States)

    Suprono, Montry S; Kattadiyil, Mathew T; Goodacre, Charles J; Winer, Myron S

    2012-10-01

    Many new products have been introduced and marketed as alternatives to traditional irreversible hydrocolloid materials. These alternative materials have the same structural formula as addition reaction silicone, also known as vinyl polysiloxane (VPS), impression materials. Currently, there is limited in vitro and in vivo research on these products, including on the effects of chemical disinfectants on the materials. The purpose of this study was to compare the effects of a spray disinfecting technique on a traditional irreversible hydrocolloid and 3 new alternative impression materials in vitro. The tests were performed in accordance with the American National Standards Institute/American Dental Association (ANSI/ADA) Specification Nos. 18 and 19. Under standardized conditions, 100 impressions were made of a ruled test block with an irreversible hydrocolloid and 3 alternative impression materials. Nondisinfected irreversible hydrocolloid was used as the control. The impressions were examined for surface detail reproduction before and after disinfection with a chloramine-T product. Type III and Type V dental stone casts were evaluated for linear dimensional change and gypsum compatibility. Comparisons of linear dimensional change were analyzed with 2-way ANOVA of mean ranks with the Scheffé post hoc comparisons (α=.05). Data for surface detail reproduction were analyzed with the Wilcoxon Signed-Rank procedure and gypsum compatibility with the Kruskal-Wallis Rank procedure (α=.05). The alternative impression materials demonstrated significantly better outcomes with all 3 parameters tested. Disinfection with chloroamine-T did not have any effect on the 3 alternative impression materials. The irreversible hydrocolloid groups produced the most variability in the measurements of linear dimensional change. All of the tested materials were within the ADA's acceptable limit of 1.0% for linear dimensional change, except for the disinfected irreversible hydrocolloid

  4. Evaluation of properties of irreversible hydrocolloid impression materials mixed with disinfectant liquids

    Directory of Open Access Journals (Sweden)

    Arul Amalan

    2013-01-01

    Conclusion: Chlorhexidine solution can be used to mix irreversible hydrocolloid impression materials in regular dental practice as it did not significantly alter the properties. This may ensure effective disinfection of impressions.

  5. Antibacterial efficacy and effect of Morinda citrifolia L. mixed with irreversible hydrocolloid for dental impressions: A randomized controlled trial.

    Science.gov (United States)

    Ahmed, A Shafath; Charles, P David; Cholan, R; Russia, M; Surya, R; Jailance, L

    2015-08-01

    This study aimed to evaluate whether the extract of Morinda citrifolia L. mixed with irreversible hydrocolloid powder decreases microbial contamination during impression making without affecting the resulting casts. Twenty volunteers were randomly divided into two groups (n = 10). Group A 30 ml extract of M. citrifolia L diluted in 30 ml of water was mixed to make the impression with irreversible hydrocolloid material. Group B 30 ml deionized water was mixed with irreversible hydrocolloid material to make the impressions following which the surface roughness and dimensional stability of casts were evaluated. Extract of M. citrifolia L. mixed with irreversible hydrocolloid decreased the percentage of microorganisms when compared with water (P impression quality.

  6. The effect of pouring time on the dimensional accuracy of casts made from different irreversible hydrocolloid impression materials

    Directory of Open Access Journals (Sweden)

    Supneet Singh Wadhwa

    2013-01-01

    Full Text Available Aims and Objectives: To determine the time dependent accuracy of casts made from three different irreversible hydrocolloids. Materials and Methods: The effect of delayed pouring on the accuracy of three different irreversible hydrocolloid impression materials - Regular set CA 37(Cavex, The Netherlands, regular set chromatic (Jeltrate, Dentsply, and fast set (Hydrogum soft, Zhermack Clinical was investigated. A brass master die that contained two identical posts simulating two complete crown-tapered abutment preparations with reference grooves served as a standardized master model. A total of 120 impressions were made using specially prepared stock-perforated brass tray with 40 impressions of each material. The impressions were further sub-grouped according to four different storage time intervals: 0 min (immediately, 12 min, 30 min, and 1 h. The impressions were stored at room temperature in a zip-lock plastic bag. Interabutment and intraabutment distances were measured in the recovered stone dies (Type IV, Kalrock using a profile projector with an accuracy of 0.001 mm. The data so obtained was analyzed statistically. Results: Results of this study showed no statistically significant differences in the accuracy of casts obtained at different time intervals. Conclusion: Because it is not always possible to pour the impression immediately in routine clinical practice, all irreversible hydrocolloid materials studied could be stored in a zip-lock plastic bag for upto 1 h without any significant distortion.

  7. Conducts of disinfection, pouring and storage of irreversible hydrocolloid impressions by undergraduate students

    Directory of Open Access Journals (Sweden)

    Thalisson Saymo de Oliveira SILVA

    Full Text Available Abstract Introduction Obtaining dental models that accurately represent the molded oral tissue requires professional attention, especially when using irreversible hydrocolloid as a molding material. Objective To evaluate the conducts of undergraduate dental students at different internships for the disinfecting procedures, pouring, and storage of irreversible hydrocolloid impressions. Material and method This is an observational, cross-sectional and descriptive study with a census sample of 89 students enrolled in the supervised internships I, II, III and IV. Data collection was performed using a structured questionnaire containing eight questions. Data were analyzed at the 5% significance level. Result Most of the students (88.8% performed the disinfection procedure, for which the most widely used method (64.6% was the application of sodium hypochlorite 1% spray stored in a sealed container. The most common disinfection time was 10 minutes (86.1%. Students in the early internships performed better in regard to the proportion of water/plaster to be used compared with students in the final internships. At all internships, pouring and storage of the ensemble of mold and model were neglected during the setting reaction. There was a statistically significant association between the stage and the disinfection method, the ratio of water/powder and pouring of the model (p<0.05. Conclusion Students exhibited appropriate conduct of disinfection; however, they should be encouraged to use evidence-based clinical practices in order to improve the procedures of pouring and storage of irreversible hydrocolloid molds.

  8. Disinfection procedures: their efficacy and effect on dimensional accuracy and surface quality of an irreversible hydrocolloid impression material.

    LENUS (Irish Health Repository)

    Rentzia, A

    2011-02-01

    This study investigated the antibacterial efficacy and effect of 0.55% ortho-phthalaldehyde (Cidex OPA(®)) and 0.5% sodium hypochlorite (NaOCl) on the dimensional accuracy and surface quality of gypsum casts retrieved from an irreversible hydrocolloid impression material.

  9. PENGUKURAN KADAR NATRIUM ALGINAT DARI ALGA COKELAT SPESIES Sargassum sp. SEBAGAI BAHAN DASAR PEMBUATAN BAHAN CETAK KEDOKTERAN GIGI (IRREVERSIBLE HYDROCOLLOID/DENTAL IMPRESSION MATERIAL)

    OpenAIRE

    MUTMAINNAH SUNAR, SITI

    2016-01-01

    2015 Pengukuran Kadar Natrium Alginate dari Alga Cokelat Spesies Sargassum sp. sebagai Bahan Dasar Pembuatan Bahan Cetak Kedokteran Gigi (Irreversible Hydrocolloid/Dental Impression Material) Siti Mutmainnah Sunar Abstrak Latar belakang : Irreversible hydrocolloid merupakan bahan cetak yang relatif sering digunakan di bidang kedokteran gigi. Namun, bahan baku dari bahan cetak ini masih diimpor dari luar negeri. Natrium alginate sebagai bahan baku masih menggunakan ekstraksi alga c...

  10. Measuring sodium alginate content of brown algae species Padina sp. as the basic matter for making dental impression material (Irreversible hydrocolloid impression material)

    OpenAIRE

    Nurlindah Hamrun; Suci Amalia Rachman

    2016-01-01

    One of the most important procedures in denture fabrication and orthodontic treatment is molding the patient’s detail oral cavity to determine the treatment planning. This procedure was done by using alginate impression material or irreversible hydrocolloid in which the basic material is sodium alginate imported from abroad because it is extracted from brown algae which its habitat is not in Indonesia so that it is causes the impression material is relatively expensive roomates is impact to h...

  11. Measuring natrium alginate content of brown algae spesies Padina sp. as the basic matter for making dental impression material (Irreversible hydrocolloid impression material)

    OpenAIRE

    Nurlindah Hamrun; Suci Amalia Rachman

    2016-01-01

    One of the most important procedure in denture fabrication and orthodontic treatment is molding the patient’s detail oral cavity to determine the treatment planning. This procedure does by using alginate impression material or irreversible hydrocolloid which is the basic material is natrium alginate which is imported from abroad because it is extracted from brown algae which habitat is not in Indonesia so it is causes the impression material is relative expensive which is impact to high cost ...

  12. Dimensional Stability of Color-Changing Irreversible Hydrocolloids after Disinfection

    Directory of Open Access Journals (Sweden)

    Khaledi AAR

    2015-03-01

    Full Text Available Statement of Problem: Disinfection of dental impressions is a weak point in the dental hygiene chain. In addition, dental office personnel and dental technicians are endangered by cross-contamination. Objectives: This study aimed to investigate the dimensional stability of two color-changing irreversible hydrocolloid materials (IH after disinfection with glutaraldehyde. Materials and Methods: In this in vitro study, impressions were made of a master maxillary arch containing three reference inserts on the occlucal surface of the left and right maxillary second molars and in the incisal surface of the maxillary central incisors. Two types of color-changing irreversible hydrocolloid (tetrachrom, cavex were used. Glutaraldehyde 2% was used in two methods of spraying and immersion to disinfect the impressions. The control group was not disinfected. Casts were made of type IV gypsum. The linear dimensional change of the stone casts was measured with a profile projector. For statistical analysis, Kruskall-Wallis and Mann-Witney tests were used (α=0.05. Results: By immersion method, the casts fabricated from tetrachrom were 0.36% larger in the anteroposterior (AP and 0.05% smaller in cross arch (CA dimensions; however, the casts prepared after spraying of tetrachrom were 0.44% larger in the AP and 0.10% smaller in CA dimensions. The casts made from Cavex were 0.05% smaller in the AP and 0.02% smaller in CA dimensions after spraying and 0.01% smaller in the AP and 0.003% smaller in CA dimensions after immersion. Generally there were not significant differences in AP and CA dimensions of the experimental groups compared to the control (p > 0.05. Conclusions: Disinfection of the tested color-changing irreversible hydrocolloids by glutaraldahyde 2% did not compromise the accuracy of the obtained casts.

  13. Determining the complex modulus of alginate irreversible hydrocolloid dental material.

    Science.gov (United States)

    King, Shalinie; See, Howard; Thomas, Graham; Swain, Michael

    2008-11-01

    The aim of the study is to investigate the visco-elastic response of an alginate irreversible hydrocolloid dental impression material during setting. A novel squeeze film Micro-Fourier Rheometer (MFR, GBC Scientific Equipment, Australia) was used to determine the complex modulus of an alginate irreversible hydrocolloid dental impression material (Algident, ISO 1563 Class A Type 1, Dentalfarm Australia Pty. Ltd.) during setting after mixing. Data was collected every 30s for 10 min in one study and every 10 min for a total of 60 min in another study. A high level of repeatability was observed. The results indicate that the MFR is capable of recording the complex shear modulus of alginate irreversible hydrocolloid for 60 min from the start of mixing and to simultaneously report the changing visco-elastic parameters at all frequencies between 1 Hz and 100 Hz. The storage modulus shows a dramatic increase to 370% of its starting value after 6 min and then reduces to 55% after 60 min. The loss modulus increases to a maximum of 175% of its starting value after 10 min and then reduces to 94% after 60 min. The MFR enables the changes in the complex modulus through the complete setting process to be followed. It is anticipated this approach may provide a better method to compare the visco-elastic properties of impression materials and assist with identification of optimum types for different clinical requirements. The high stiffness of the instrument and the use of band-limited pseudo-random noise as the input signal are the main advantages of this technique over conventional rheometers for determining the changes in alginate visco-elasticity.

  14. Influence of delayed pouring on irreversible hydrocolloid properties

    Directory of Open Access Journals (Sweden)

    Stéfani Becker Rodrigues

    2012-10-01

    Full Text Available The aim of this study was to evaluate the physical properties of irreversible hydrocolloid materials poured immediately and after different storage periods. Four alginates were tested: Color Change (Cavex; Hydrogum (Zhermack; Hydrogum 5 (Zhermack; and Hydro Print Premium (Coltene. Their physical properties, including the recovery from deformation (n = 3, compressive strength (n = 3, and detail reproduction and gypsum compatibility (n = 3, were analyzed according to ANSI/ADA specification no. 18. Specimens were stored at 23ºC and humidity and were then poured with gypsum immediately and after 1, 2, 3, 4, and 5 days. The data were analyzed by two-way analysis of variance (ANOVA and Tukey's test at p < 0.05. All of the alginate impression materials tested exhibited detail reproduction and gypsum compatibility at all times. Hydro Print Premium and Hydrogum 5 showed recovery from deformation, as established by ANSI/ADA specification no. 18, after 5 days of storage. As the storage time increased, the compressive strength values also increased. Considering the properties of compounds' recovery from deformation, compressive strength, and detail reproduction and gypsum compatibility, irreversible hydrocolloids should be poured immediately.

  15. In vitro antimicrobial activity of irreversible hydrocolloid impressions against 12 oral microorganisms

    OpenAIRE

    Casemiro,Luciana Assirati; Pires-de-Souza,Fernanda de Carvalho Panzeri; Panzeri,Heitor; Martins,Carlos Henrique Gomes; Ito,Isabel Yoko

    2007-01-01

    This study evaluated in vitro the antimicrobial activity of irreversible hydrocolloids (one containing an antimicrobial agent) prepared with water or with a 0.2% chlorhexidine digluconate solution against 12 strains of the oral microbiota. Twenty specimens (0.5 x 1.0 cm) for each group (1. Jeltrate mixed with water; 2. Jeltrate mixed with 0.2% chlorhexidine digluconate solution; 3. Greengel mixed with water; 4. Greengel mixed with 0.2% chlorhexidine digluconate solution) were prepared under s...

  16. Measuring sodium alginate content of brown algae species Padina sp. as the basic matter for making dental impression material (Irreversible hydrocolloid impression material

    Directory of Open Access Journals (Sweden)

    Nurlindah Hamrun

    2016-08-01

    Full Text Available One of the most important procedures in denture fabrication and orthodontic treatment is molding the patient’s detail oral cavity to determine the treatment planning. This procedure was done by using alginate impression material or irreversible hydrocolloid in which the basic material is sodium alginate imported from abroad because it is extracted from brown algae which its habitat is not in Indonesia so that it is causes the impression material is relatively expensive roomates is impact to high cost of dental treatment. Indonesia as the archipelago country has availability of abundant brown algae Padina sp. Especially in Puntondo-Punaga seashore, South Sulawesi, but it has not Cultivate yet by the local society because it is never discovered by alginate industry so it is just grow wild and its potency is useless. This experiment identified the purposes of how much sodium alginate is produced from Padina Sp. Extraction as the basic matter of irreversible hydrocolloid. The design of this study is experimental design with one shot case study method. In early stage research, extraction of alginate in the form of sodium alginate. After that, they are weighted by using analytical weight in milligrams (mg unit. Then, it is compare with the standard sodium alginate to observe the similarity of molecules by using FTIR (Fourier Transform Infra Red device. Data were Analyzed using mean differences. Based on Padina extracted, produced 12.86 g of sodium alginate content or 28.4% from the cleaning algae was used roomates total weight is 45 g. Based on FTIR test, showed that sodium alginate is extracted similar to the standard sodium alginate with the found of hydroxyl, carboxylic acid, ether group and the which is the composer of sodium alginate. In conclusion, from both of infra red spectrum pattern, it was observed unsignificant difference. Extracted sodium alginate Padina is same with the standard sodium alginate and it has 12.86 g content.

  17. Measuring natrium alginate content of brown algae spesies Padina sp. as the basic matter for making dental impression material (Irreversible hydrocolloid impression material

    Directory of Open Access Journals (Sweden)

    Nurlindah Hamrun

    2016-06-01

    Full Text Available One of the most important procedure in denture fabrication and orthodontic treatment is molding the patient’s detail oral cavity to determine the treatment planning. This procedure does by using alginate impression material or irreversible hydrocolloid which is the basic material is natrium alginate which is imported from abroad because it is extracted from brown algae which habitat is not in Indonesia so it is causes the impression material is relative expensive which is impact to high cost of dental treatment. Indonesia as the archipelago country has availability of abundant brown algae Padina sp. especially in Puntondo-Punaga seashore, South Sulawesi, but it has not cultivate yet by the local society because it is never discover by alginate industry so it is just grow wild and it’s potency is useless. This experiment purposes to identified how much natrium alginate is producted from Padina Sp. extraction as the basic matter of irreversible hydrocolloid. The design of this study is conducted by experimental design with one shot case study method. Early stage research, extraction of alginate in form of natrium alginate. After that it is weighted by using analytical weight in milligram (mg unit. Then, it is compare with the standard natrium alginate to observe the similarity of molecule by using FTIR device. Data were analyzed using uji rerata. Based on extracted Padina sp, produced 12.86 g natrium alginate content or 28,4% from the alga dry weight total was used which is 45 g. Based on FTIR test, showed that extracted natrium alginate is similar with the standard natrium alginate with the found of hidroxyl, carboxylate, and eter group which is composer of natrium alginate. From both of infra red spectrum pattern, it was observed unsignificant difference. Extracted natrium alginate Padinasp is same with the standard natrium alginate and it has content 12.86 g.

  18. Linear Dimensional Stability of Irreversible Hydrocolloid Materials Over Time.

    Science.gov (United States)

    Garrofé, Analía B; Ferrari, Beatriz A; Picca, Mariana; Kaplan, Andrea E

    2015-12-01

    The aim of this study was to evaluate the linear dimensional stability of different irreversible hydrocolloid materials over time. A metal mold was designed with custom trays made of thermoplastic sheets (Sabilex, sheets 0.125 mm thick). Perforations were made in order to improve retention of the material. Five impressions were taken with each of the following: Kromopan 100 (LASCOD) [AlKr], which has dimensional stability of 100 hours, and Phase Plus (ZHERMACK) [AlPh], which has dimensional stability of 48 hours. Standardized digital photographs were taken at different time intervals (0, 15, 30, 45, 60, 120 minutes; 12, 24 and 96 hours), using an "ad-hoc" device. The images were analyzed with software (UTHSCSA Image Tool) by measuring the distance between intersection of the lines previously made at the top of the mold. The results were analyzed by ANOVA for repeated measures. Initial and final values were (mean and standard deviation): AlKr: 16.44 (0.22) and 16.34 (0.11), AlPh: 16.40 (0.06) and 16.18 (0.06). Statistical evaluation showed significant effect of material and time factors. Under the conditions in this study, time significantly affects the linear dimensional stability of irreversible hydrocolloid materials. Sociedad Argentina de Investigación Odontológica.

  19. Physical characteristic of brown algae (Phaeophyta from madura strait as irreversible hydrocolloid impression material

    Directory of Open Access Journals (Sweden)

    Prihartini Widiyanti

    2012-09-01

    Full Text Available Background: Brown algae is a raw material for producing natrium alginates. One type of brown algae is Sargassum sp, a member of Phaeophyta division. Sargassum sp could be found in Madura strait Indonesia. Natrium alginate can be extracted from Sargassum sp. The demand of alginate in Indonesia is mainly fulfilled from abroad, meanwhile Sargassum sp is abundantly available. Purpose: The purpose of study were to explore the potency of brown alga Sargassum sp from Madura strait as hydrocolloid impression material and to examine its physical characteristic. Methods: The methods of research including extraction natrium alginate from Sargassum sp, synthesis of dental impression material and the test of porosity, density, viscosity, and water content of impression material which fulfilled the standard of material used in clinical application in dentistry. Results: Extraction result of Sargassum sp was natrium alginate powder with cream colour, odorless, and water soluble. The water content of natrium alginate was 21.64% and the viscosity was 0.7 cPs. The best porosity result in the sample with the addition of trinatrium phosphate 4% was 3.61%. Density value of impression material was 3 gr/cm3. Conclusion: The research suggested that brown algae Sargassum sp from Madura strait is potential as hydrocolloid impression material, due to its physical properties which close to dental impression material, but still need further research to optimize the physical characteristic.Latar belakang: Alga coklat adalah sumber bahan baku material natrium alginat. Salah satu jenis alga coklat adalah Sargassum sp yang merupakan anggota divisi Phaeophyta. Sargassum sp dapat ditemukan di Selat Madura Indonesia. Natrium alginat dapat diekstraksi dari Sargassum sp. Kebutuhan akan bahan ini di Indonesia sebagian besar dipenuhi dari impor, padahal ketersediaan Sargassum sp di Indonesia sangat melimpah. Tujuan: Penelitian ini bertujuan untuk mengeksplorasi potensi alga coklat

  20. Effect of Time on Gypsum-Impression Material Compatibility

    Science.gov (United States)

    Won, John Boram

    The purpose of this study was to evaluate the compatibility of dental gypsum with three recently introduced irreversible hydrocolloid (alginate) alternatives. The test materials were Alginot® (Kerr™), Position Penta Quick® (3M ESPE™) and Silgimix ® (Sultan Dental™). The irreversible hydrocolloid impression material, Jeltrate Plus antimicrobial® (Dentsply Caulk™) served as the control. Materials and Methods: Testing of materials was conducted in accordance with ANSI/ADA Specification No. 18 for Alginate Impression Materials. Statistical Analysis: The 3-Way ANOVA test was used to analyze measurements between different time points at a significance level of (p Outcome: It was found that there was greater compatibility between gypsum and the alternative materials over time than the traditional irreversible hydrocolloid material that was tested. A statistically significant amount of surface change/incompatibility was found over time with the combination of the dental gypsum products and the control impression material (Jeltrate Plus antimicrobial®).

  1. Antimicrobial Property of Hydrocolloid Impression Material Incorporated with Silver Nanoparticles Against Staphylococcus Aureus

    Directory of Open Access Journals (Sweden)

    Wangchuk Norbu Penden

    2017-01-01

    Full Text Available Dental impressions can easily become contaminated with patient’s blood and saliva which are capable of transmitting infectious diseases to dental personnel. The addition of antimicrobial agents into impression materials could be effective in reducing the chances of cross-infection. Silver nanoparticles have been applied in dentistry as a potent antimicrobial agent. This study aims to evaluate the in vitro antimicrobial efficacy of silver nanoparticles incorporated to irreversible hydrocolloid impression material against Staphylococcus aureus. Silver nanoparticles (AgZrPO4, National Direct Network Company, Thailand at concentrations of 0.25%, 0.50%, 1.00% and 1.50% w/w were added to powder of impression materials (Kromopan, Lascod, Ilaty. Impression material samples were prepared on sterile plate in accordance with manufacturer’s instruction. After setting, a 100 microliter of S. aureus ATCC6538 suspension (106 cells/mL were inoculated on the surface of the impression sample and left for 10 minutes. The amount of S. aureus on the surface was quantified using imprint technique on Mannitol Salt agar. Impression materials incorporated with AgZrPO4 showed antimicrobial property against S. aureus (up to 95% reduction compared with control (impression material without AgZrPO4. Even though the mechanism of antimicrobial action was not clearly understood, AgZrPO4 incorporated to impression material was demonstrated to possess an inhibitory effect against pathogenic bacteria. Further studies are needed to investigate physical properties of the material and the clinical usage.

  2. An Investigation into the Accuracy of Two Currently Available Dental Impression Materials in the Construction of Cobalt-Chromium Frameworks for Removable Partial Dentures.

    Science.gov (United States)

    Dubal, Rajesh Kumar; Friel, Tim; Taylor, Philip D

    2015-03-01

    This study investigated the suitability of irreversible hydrocolloid as an impression material for cobalt-chromium framework construction. Scans of casts derived from (1) alginate and (2) addition-cured polyvinylsiloxane impressions were superposed on to a control. The differences within and between groups were compared at fixed landmarks. The investigation revealed a high degree of scan coincidence within and between groups. However, certain features, such as undercuts, resulted in a lower degree of scan coincidence. Irreversible hydrocolloid appears to be a viable alternative to addition-cured polyvinyl-siloxane as an impression material for cobalt-chromium framework construction.

  3. Physical characteristic of brown algae (Phaeophyta) from madura strait as irreversible hydrocolloid impression material

    OpenAIRE

    Prihartini Widiyanti; Siswanto Siswanto

    2012-01-01

    Background: Brown algae is a raw material for producing natrium alginates. One type of brown algae is Sargassum sp, a member of Phaeophyta division. Sargassum sp could be found in Madura strait Indonesia. Natrium alginate can be extracted from Sargassum sp. The demand of alginate in Indonesia is mainly fulfilled from abroad, meanwhile Sargassum sp is abundantly available. Purpose: The purpose of study were to explore the potency of brown alga Sargassum sp from Madura strait as hydrocolloid im...

  4. The fungicidal effect of ultraviolet light on impression materials

    International Nuclear Information System (INIS)

    Ishida, H.; Nahara, Y.; Tamamoto, M.; Hamada, T.

    1991-01-01

    The effects of ultraviolet (UV) light on fungi and impression materials were tested. UV light (250 microW/cm2) killed most Candida organisms (10(3) cells/ml) within 5 minutes. UV light (8000 microW/cm2) killed most C. albicans (10(7) cells/ml) within 2 minutes of exposure. The effect of UV light on dimensional change and surface roughness of impression materials (irreversible hydrocolloid, agar, and silicone rubber) was tested. The results showed that neither dimensional change nor surface roughness of the impression materials were affected. The results of this study indicate that UV light disinfects impression materials that are contaminated with Candida organisms

  5. Precision of guided scanning procedures for full-arch digital impressions in vivo.

    Science.gov (United States)

    Zimmermann, Moritz; Koller, Christina; Rumetsch, Moritz; Ender, Andreas; Mehl, Albert

    2017-11-01

    System-specific scanning strategies have been shown to influence the accuracy of full-arch digital impressions. Special guided scanning procedures have been implemented for specific intraoral scanning systems with special regard to the digital orthodontic workflow. The aim of this study was to evaluate the precision of guided scanning procedures compared to conventional impression techniques in vivo. Two intraoral scanning systems with implemented full-arch guided scanning procedures (Cerec Omnicam Ortho; Ormco Lythos) were included along with one conventional impression technique with irreversible hydrocolloid material (alginate). Full-arch impressions were taken three times each from 5 participants (n = 15). Impressions were then compared within the test groups using a point-to-surface distance method after best-fit model matching (OraCheck). Precision was calculated using the (90-10%)/2 quantile and statistical analysis with one-way repeated measures ANOVA and post hoc Bonferroni test was performed. The conventional impression technique with alginate showed the lowest precision for full-arch impressions with 162.2 ± 71.3 µm. Both guided scanning procedures performed statistically significantly better than the conventional impression technique (p Cerec Omnicam Ortho were 74.5 ± 39.2 µm and for group Ormco Lythos 91.4 ± 48.8 µm. The in vivo precision of guided scanning procedures exceeds conventional impression techniques with the irreversible hydrocolloid material alginate. Guided scanning procedures may be highly promising for clinical applications, especially for digital orthodontic workflows.

  6. Effect of Storage Time of Extended-Pour and Conventional Alginate Impressions on Dimensional Accuracy of Casts

    OpenAIRE

    Rohanian, Ahmad; Ommati Shabestari, Ghasem; Zeighami, Somayeh; Samadi, Mohammad Javad; Shamshiri, Ahmad Reza

    2014-01-01

    Objectives: Some manufacturers claim to have produced new irreversible hydro-colloids that are able to maintain their dimensional stability during storage. The present study evaluated the effect of storage time on dimensional stability of three alginates: Hydrogum 5, Tropicalgin and Alginoplast. Materials and Methods: In this experimental in-vitro trial, a total of 90 alginate impressions were made from a Dentoform model using Hydrogum 5, Tropicalgin and Alginoplast alginates. The impressions...

  7. Does 6 Hours of Contact With Alginate Impression Material Affect Dental Cast Properties?

    Science.gov (United States)

    Ibrahim, Amna Adam; Alhajj, Mohammed Nasser; Khalifa, Nadia; Gilada, Magdi Wadie

    2017-06-01

    Alginate impression (irreversible hydrocolloid) material is commonly used in dental practice because it is easy to mix, low in cost, and well tolerated by patients. The material is not dimensionally stable, however; thus, it is necessary to pour the impression immediately after the molding is accomplished, or within 60 minutes if the impression is kept in 100% humidity. Excessive contact of the alginate impression with the cast model over time may affect the model's properties. In this study, the authors tested the effect of contact time between an alginate impression and type III dental stone on cast model properties. Sixty-seven cast models were obtained from a stainless steel cylinder by using irreversible hydrocolloid impression material and type III dental stone. Thirty-seven cast models were separated from the impression after 1 hour (control group) and 30 cast models were separated after 6 hours (study group). The samples were evaluated under light microscope for surface details and measured by digital caliper for dimensional stability. An indentation on the cast was made and the depth of the indentation was then measured with a digital caliper to measure hardness. The dimensional stability of the cast models was not affected when contact time was increased from 1 hour to 6 hours (P = .507). Surface details did not deteriorate when contact time was increased, as all of the samples could reproduce all details after the 1-hour and 6-hour interval periods. However, hardness was greater after 1 hour of contact time (P = .001) than after 6 hours of contact time. In conclusion, contact between alginate impression material and type III dental stone up to 6 hours did not affect the dimensional stability and richness of the surface; hardness, though, was significantly affected.

  8. Bacterial, fungal and yeast contamination in six brands of irreversible hydrocolloid impression materials Contaminação por bactérias, fungos e leveduras em seis marcas comerciais de materiais de moldagem à base de hidrocolóide irreversível

    OpenAIRE

    Luciana Assirati Casemiro; Carlos Henrique Gomes Martins; Fernanda de Carvalho Panzeri Pires de Souza; Heitor Panzeri; Isabel Yoko Ito

    2007-01-01

    This study assessed the level of contamination of six commercially available irreversible hydrocolloids (two containing chlorhexidine) and identified the contamination present in the materials. Petri dishes containing selective and enriched culture media were inoculated with alginate powder (0.06 g), in triplicate. After incubation (37°C/7 days), the colony-forming units (CFU) were counted and Gram stained. Biochemical identification of the different morphotypes was also performed. The co...

  9. A review of extractions of seaweed hydrocolloids: Properties and applications

    Directory of Open Access Journals (Sweden)

    H. P. S. Abdul Khalil

    2018-04-01

    Full Text Available The term hydrocolloid generally refers to substances that form gels or provide viscous dispersion in the presence of water. Alginate, agar, and carrageenan are three commercially valuable hydrocolloids derived from certain brown and red seaweed and each has their distinct physicochemical properties (i.e. functional and bioactive. Various applications of these seaweed hydrocolloids as thickeners, stabilizers, coagulants and salves (in the wound and burn dressings and materials to produce bio-medical impressions in the food, pharmaceutical, and biotechnology industries are highlighted in this review. Although the existing industrial methods of extraction for these seaweed hydrocolloids are well-established, still growing demand has exposed certain limitations of those methods, notably efficiency and product consistency. In order to achieve targeted hydrocolloids for specific purposes and functionalities, some novel and green extraction methods have also been proposed and discussed. Microwave-assisted extraction (MAE, ultrasound-assisted extraction (UAE, enzyme-assisted extraction (EAE, supercritical fluid extraction (SFE, pressurized solvent extractions (PSE, reactive extrusion and photobleaching process are selectively presented as highly promising candidates that can avoid the use of chemicals and provide novel means of access to seaweed hydrocolloids with both economic and environmental benefits. However, this review does not provide the ‘best’ method or procedure as many are still under development. Hence, the review gives ‘food for thought’as to new processes which might be adopted industrially and concluded that further research is required in order to contribute additional new knowledge and refinement to this field of study.

  10. Photogrammetry Impression Technique: A Case History Report.

    Science.gov (United States)

    Sánchez-Monescillo, Andrés; Sánchez-Turrión, Andrés; Vellon-Domarco, Elena; Salinas-Goodier, Carmen; Prados-Frutos, Juan Carlos

    2016-01-01

    The aim of this report is to present photogrammetry as a reliable step in the fabrication of a full-arch immediate rehabilitation. A 59-year-old man attended the department seeking dental rehabilitation for the sequelae of severe oral health neglect. The mandibular teeth suffered from advanced periodontal disease and the patient wore a maxillary complete denture. An irreversible hydrocolloid impression of the mandibular arch was made, poured in stone, and digitally scanned to create the first stereolithography (STL) file. All teeth with the exception of two retained as landmarks were extracted, and seven implants were placed under local anesthesia and their positions recorded using photogrammetry. Maxillary and mandibular dental arch alginate impressions were made, poured in laboratory stone, and scanned. A provisional restoration was placed 7 hours after surgery using the STL files to determine the best-fit line. Radiographic and clinical follow-up after 1 year showed a favorable evolution of the implants. No screw loosening or other mechanical or biologic complications were observed. The case history using the described system suggests certain advantages over conventional techniques. More research is needed to assess the possible benefits associated with photogrammetry when making implant-supported restorations.

  11. Accuracy and dimensional stability of extended-pour and conventional alginate impression materials.

    Science.gov (United States)

    Imbery, Terence A; Nehring, Joshua; Janus, Charles; Moon, Peter C

    2010-01-01

    The authors conducted a study to determine if two irreversible hydrocolloid impression materials (Cavex ColorChange, Cavex Holland BV, Haarlem, Netherlands; Jeltrate Plus Antimicrobial Dustless Alginate Impression Material, Dentsply Caulk, Milford, Del.) stored for five days were dimensionally accurate. The authors modified Ivorine teeth (Columbia Dentoform, Long Island City, N.Y.) on a Dentoform model (1560 series model, Columbia Dentoform) to allow measurements of tooth and arch width. They made impressions and generated casts immediately and at five additional times. They recorded tooth and arch widths on the casts and compared the measurements with those for the standard model. Compared with measurements for the model, the greatest measured difference in casts was 0.003 inches for Cavex ColorChange (extended-pour alginate) and 0.005 inches for Jeltrate Plus Antimicrobial Dustless Alginate Impression Material (conventional alginate). The percentage of dimensional change ranged from -0.496 to 0.161 percent for the extended-pour alginate and from -0.174 to 0.912 percent for the conventional alginate. Results of analysis of variance and paired t tests indicated that when generated immediately and at day 5, casts produced from both impression materials were not statistically different from the standard model (P alginate materials can produce accurate impressions at day 5 for diagnostic casts and for fabrication of acrylic appliances.

  12. Antibacterial Effect of Sanosil 2% and 6% and Sodium Hypochlorite 0.5% on Impressions of Irreversible Hydrocolloid (Alginate) and Condensational Silicone (Speedex)

    OpenAIRE

    Izadi; Farnaz; Soufiabadi; Vafaee; Kasraei

    2013-01-01

    Background Dental impressions often carry microorganisms that may cause cross-infection from patients to dental staff. Impressions should be disinfected to eliminate the risk of cross-contamination. Objectives The aim of this study was to determine the effectiveness of three different disinfectant solutions on two commonly used impression materials. Materials and Methods Seventy-tw...

  13. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions.

    Science.gov (United States)

    Ender, Andreas; Attin, Thomas; Mehl, Albert

    2016-03-01

    Digital impression systems have undergone significant development in recent years, but few studies have investigated the accuracy of the technique in vivo, particularly compared with conventional impression techniques. The purpose of this in vivo study was to investigate the precision of conventional and digital methods for complete-arch impressions. Complete-arch impressions were obtained using 5 conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; digitized scannable vinylsiloxanether, VSES-D; and irreversible hydrocolloid, ALG) and 7 digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; Lava COS, LAV; Lava True Definition Scanner, T-Def; 3Shape Trios, TRI; and 3Shape Trios Color, TRC) techniques. Impressions were made 3 times each in 5 participants (N=15). The impressions were then compared within and between the test groups. The cast surfaces were measured point-to-point using the signed nearest neighbor method. Precision was calculated from the (90%-10%)/2 percentile value. The precision ranged from 12.3 μm (VSE) to 167.2 μm (ALG), with the highest precision in the VSE and VSES groups. The deviation pattern varied distinctly according to the impression method. Conventional impressions showed the highest accuracy across the complete dental arch in all groups, except for the ALG group. Conventional and digital impression methods differ significantly in the complete-arch accuracy. Digital impression systems had higher local deviations within the complete arch cast; however, they achieve equal and higher precision than some conventional impression materials. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions.

    Science.gov (United States)

    Ender, Andreas; Mehl, Albert

    2015-01-01

    To investigate the accuracy of conventional and digital impression methods used to obtain full-arch impressions by using an in-vitro reference model. Eight different conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; and irreversible hydrocolloid, ALG) and digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; and Lava COS, LAV) full-arch impressions were obtained from a reference model with a known morphology, using a highly accurate reference scanner. The impressions obtained were then compared with the original geometry of the reference model and within each test group. A point-to-point measurement of the surface of the model using the signed nearest neighbour method resulted in a mean (10%-90%)/2 percentile value for the difference between the impression and original model (trueness) as well as the difference between impressions within a test group (precision). Trueness values ranged from 11.5 μm (VSE) to 60.2 μm (POE), and precision ranged from 12.3 μm (VSE) to 66.7 μm (POE). Among the test groups, VSE, VSES, and CER showed the highest trueness and precision. The deviation pattern varied with the impression method. Conventional impressions showed high accuracy across the full dental arch in all groups, except POE and ALG. Conventional and digital impression methods show differences regarding full-arch accuracy. Digital impression systems reveal higher local deviations of the full-arch model. Digital intraoral impression systems do not show superior accuracy compared to highly accurate conventional impression techniques. However, they provide excellent clinical results within their indications applying the correct scanning technique.

  15. Effect of hydrocolloids on the physico-chemical and rheological properties of reconstituted sweetened yoghurt powder.

    Science.gov (United States)

    Seth, Dibyakanta; Mishra, Hari Niwas; Deka, Sankar Chandra

    2018-03-01

    The consistency of sweetened yoghurt (misti dahi) is a desired characteristic which is attributed to the casein protein network formation during fermentation. Unfortunately, this property is lost in reconstituted sweetened yoghurt (RSY) due to the irreversible nature of protein denaturation during spray drying. Therefore, this study aimed to increase the consistency of RSY using different hydrocolloids. The effects addition of guar gum, pectin, κ-carrageenan and gelatin (0.1%w/v each) on the physico-chemical, microbial, rheological and sensory properties of RSY were investigated. RSY with 40% total solids demonstrated the rheological properties which are very similar to those of fresh sweetened yoghurt. RSY containing different hydrocolloids further increased the rheological properties. The dynamic rheological study revealed that the magnitude of storage modulus (G'), loss modulus (G″), and loss tangent (tan δ) were significantly influenced by the addition of hydrocolloids and gelatin exhibited highest dynamic moduli in RSY. However, κ-carrageenan added RSY was preferred sensorially as the rheological properties were very close to gelatin added RSY. Addition of hydrocolloids significantly increased the starter bacteria count and pH and reduced water expulsion rate (P < 0.05). Addition of hydrocolloids can improve the rheological properties of reconstituted yoghurt. The study concluded that the addition of κ-carrageenan showed better results in terms of rheological and sensory properties of RSY. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  16. Functional hydrocolloids from seaweeds

    DEFF Research Database (Denmark)

    Rhein-Knudsen, Nanna; Meyer, Anne S.

    2017-01-01

    The global production of seaweeds continues to grow for production of food hydrocolloids, i.e. carbohydrate polymers that form viscous suspensions and gels in water. Because of their unique gelling properties seaweed hydrocolloids are used in various food and pharmaceutical applications. Asian...

  17. Effect of storage time of extended-pour and conventional alginate impressions on dimensional accuracy of casts.

    Science.gov (United States)

    Rohanian, Ahmad; Ommati Shabestari, Ghasem; Zeighami, Somayeh; Samadi, Mohammad Javad; Shamshiri, Ahmad Reza

    2014-11-01

    Some manufacturers claim to have produced new irreversible hydro-colloids that are able to maintain their dimensional stability during storage. The present study evaluated the effect of storage time on dimensional stability of three alginates: Hydrogum 5, Tropicalgin and Alginoplast. In this experimental in-vitro trial, a total of 90 alginate impressions were made from a Dentoform model using Hydrogum 5, Tropicalgin and Alginoplast alginates. The impressions were stored in a sealed plastic bag without a damp paper towel for 0, 24, 48, 72 and 120 hours and then poured with type III dental stone. Cross-arch (facial of 6 to facial of 6 on the opposite side) and antero-posterior (distal of right first molar to the ipsilateral central incisor) measurements were made with a digital caliper on the casts. Data were analyzed by two-way and one-way ANOVA and Tukey's post-hoc test (Pimpressions (both Psimpressions can be delayed for up to 120 hours without significant dimensional changes. Alginoplast impressions may be poured after 72 hours, but Tropicalgin should be poured immediately and the storage time should not be more than 24 hours. Immediate pouring of alginate impressions provides the highest accuracy in reproducing the teeth and adjacent tissues; however, this study demonstrated that pouring may be delayed for up to five days using extended-pour (Hydrogum 5) alginates.

  18. Effect of storage time of extended-pour and conventional alginate impressions on dimensional accuracy of casts.

    Directory of Open Access Journals (Sweden)

    Ahmad Rohanian

    2014-12-01

    Full Text Available Some manufacturers claim to have produced new irreversible hydro-colloids that are able to maintain their dimensional stability during storage. The present study evaluated the effect of storage time on dimensional stability of three alginates: Hydrogum 5, Tropicalgin and Alginoplast.In this experimental in-vitro trial, a total of 90 alginate impressions were made from a Dentoform model using Hydrogum 5, Tropicalgin and Alginoplast alginates. The impressions were stored in a sealed plastic bag without a damp paper towel for 0, 24, 48, 72 and 120 hours and then poured with type III dental stone. Cross-arch (facial of 6 to facial of 6 on the opposite side and antero-posterior (distal of right first molar to the ipsilateral central incisor measurements were made with a digital caliper on the casts. Data were analyzed by two-way and one-way ANOVA and Tukey's post-hoc test (P<0.05.Alginate type and the pouring time significantly affected the dimensional stability of alginate impressions (both Ps<0.001. Pouring of Hydrogum 5 impressions can be delayed for up to 120 hours without significant dimensional changes. Alginoplast impressions may be poured after 72 hours, but Tropicalgin should be poured immediately and the storage time should not be more than 24 hours.Immediate pouring of alginate impressions provides the highest accuracy in reproducing the teeth and adjacent tissues; however, this study demonstrated that pouring may be delayed for up to five days using extended-pour (Hydrogum 5 alginates.

  19. Torque resistance of impression copings after direct implant impression: An in vitro evaluation of impression materials with and without adhesive.

    Science.gov (United States)

    Auroy, Pascal; Nicolas, Emanuel; Bedouin, Yvan

    2017-01-01

    No data are available on the ability of an impression coping to resist the manual placement of an abutment replica (implant analog) during prosthodontic laboratory procedures after a direct (pick-up) impression. The purpose of this in vitro study was to evaluate the torque resistance of impression copings after a direct impression, that is, the amount of rotational torque sufficient to induce irreversible displacement of impression copings in the impression material bulk once the impression has been made. A reference model with 5 abutment replicas was constructed. Five impression copings were screwed onto the abutment replicas, and standardized impressions were made. A controlled twisting force was applied to each impression coping. A torque tester recorded the torque variation. Three elastomeric impression materials were tested. ANOVA and the Tukey test (α=.05) were performed using an average of 30 measurements per impression material, with and without adhesive. ANOVA and the Tukey test results showed that the adhesive, cohesive, and mechanical bonds between the impression coping and the impression material depended greatly on the type of material and that the average rupture threshold of these bonds was statistically significantly different in pairwise comparisons (Ptorque. The polyether impression material is the direct impression material that showed the highest breakdown threshold for adhesive bonding when used without an adhesive. The use of an adhesive on impression copings leads to irreversible deformation of the interface at torque stresses well below the adhesive bond threshold of the same materials used without an adhesive. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. In vitro antimicrobial activity of irreversible hydrocolloid impressions against 12 oral microorganisms Atividade antimicrobiana in vitro de moldes de hidrocolóide irreversível contra 12 microrganismos orais

    Directory of Open Access Journals (Sweden)

    Luciana Assirati Casemiro

    2007-12-01

    Full Text Available This study evaluated in vitro the antimicrobial activity of irreversible hydrocolloids (one containing an antimicrobial agent prepared with water or with a 0.2% chlorhexidine digluconate solution against 12 strains of the oral microbiota. Twenty specimens (0.5 x 1.0 cm for each group (1. Jeltrate mixed with water; 2. Jeltrate mixed with 0.2% chlorhexidine digluconate solution; 3. Greengel mixed with water; 4. Greengel mixed with 0.2% chlorhexidine digluconate solution were prepared under sterile conditions and placed in culture media inoculated with the indicator strains. After incubation in aerobiosis or microaerophilia, inhibition of the microbial growth was measured and the results were interpreted. The normal adherence curve revealed a non-normal distribution of the data, so the non-parametric Friedman Test was performed (p Este trabalho avaliou in vitro a atividade antimicrobiana de alginatos (um deles contendo agente antimicrobiano manipulados com água ou solução de digluconato de clorexidina a 0,2% contra 12 cepas da microbiota oral. Vinte espécimes (0,5 x 1,0 cm para cada grupo (1. Jeltrate manipulado com água, 2. Jeltrate manipulado com solução de digluconato de clorexidina a 0,2%; 3. Greengel manipulado com água; 4. Greengel manipulado com solução de digluconato de clorexidina a 0,2% foram confeccionados sob condições estéreis e semeados em meios de cultura inoculados com as cepas indicadoras. Após incubação em aerobiose ou microaerofilia, a inibição do crescimento microbiano foi medida e os resultados foram interpretados. A curva normal de aderência revelou uma distribuição não-normal dos dados, então o teste não paramétrico de Friedman (p < 0,05 foi realizado. A atividade antimicrobiana dos grupos foi classificada na seguinte ordem crescente: 1, 3, 4 e 2. Os resultados sugerem que a manipulação de alginatos com solução de digluconato de clorexidina a 0,2% é um método efetivo para reduzir a contamina

  1. Improving adhesion of seasonings to crackers with hydrocolloid solutions.

    Science.gov (United States)

    Armstrong, Matthew E; Barringer, Sheryl A

    2013-11-01

    Food powders were applied on crackers that had been coated using water, oil, emulsion, sucrose, or hydrocolloid solutions. The hydrocolloids that were used include gellan gum, kappa-carrageenan, methylcellulose, gum karaya, gum tragacanth, gum arabic, guar gum, modified starch, and maltodextrin. Solutions of similar hydrophobicity to the powder gave the greatest adhesion. NaCl, barbecue (BBQ), ranch, and sour cream & onion (SC&O) seasoning showed greatest adhesion with water, cheese powder with an emulsion of 12.5% to 25% oil, and cocoa powder with oil. For NaCl, BBQ, ranch, and SC&O seasoning, hydrocolloids improved the adhesion over using water alone, with gellan gum providing the greatest adhesion. Hydrocolloid structural differences, including the presence or absence of branching, substitution of sugar units, and molecular weight affect water binding and thickening of the hydrocolloid spray that seemed to be significant factors affecting adhesion of powders to the target surface. For cheese powder, hydrocolloids were capable of replacing the oil within an emulsion while improving or maintaining the same level of adhesion, with gum arabic providing the greatest adhesion. For cocoa powder, hydrocolloid solutions were ineffective adhesives due to differences in hydrophilicity that result in insolubility. The effect of hydrocolloid concentration on adhesion was dependent both on the hydrocolloid type and the concentration that is sprayable, with 0.5% being the optimum concentration for most gums. Adhesion using sucrose solutions was determined by particle size and relative hydrophobicity. Increasing sucrose concentration decreased adhesion of smaller particles, but increased adhesion of larger particles. Adhesion of NaCl significantly increased with decreasing NaCl size using oil, water, and sucrose solutions. © 2013 Institute of Food Technologists®

  2. Seaweed Hydrocolloid Production: An Update on Enzyme Assisted Extraction and Modification Technologies

    DEFF Research Database (Denmark)

    Rhein-Knudsen, Nanna; Ale, Marcel Tutor; Meyer, Anne S.

    2015-01-01

    Agar, alginate, and carrageenans are high-value seaweed hydrocolloids, which are used as gelation and thickening agents in different food, pharmaceutical, and biotechnological applications. The annual global production of these hydrocolloids has recently reached 100,000 tons with a gross market......-made modifications of the hydrocolloids to obtain specific functionalities. This review provides an update of the detailed structural features of κ-, ι-, λ-carrageenans, agars, and alginate, and a thorough discussion of enzyme assisted extraction and processing techniques for these hydrocolloids....

  3. Hydrocolloid-based nutraceutical delivery systems

    Energy Technology Data Exchange (ETDEWEB)

    Janaswamy, Srinivas; Youngren, Susanne R. (Purdue)

    2012-07-11

    Nutraceuticals are important due to their inherent health benefits. However, utilization and consumption are limited by their poor water solubility and instability at normal processing and storage conditions. Herein, we propose an elegant and novel approach for the delivery of nutraceuticals in their active form using hydrocolloid matrices that are inexpensive and non-toxic with generally recognized as safe (GRAS) status. Iota-carrageenan and curcumin have been chosen as models of hydrocolloid and nutraceutical compounds, respectively. The iota-carrageenan network maintains a stable organization after encapsulating curcumin molecules, protects them from melting and then releases them in a sustained manner. These findings lay a strong foundation for developing value-added functional and medicinal foods.

  4. Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber

    Directory of Open Access Journals (Sweden)

    Rupandeep Kaur Samra

    2018-04-01

    Full Text Available Objectives: It was to analyse and compare the effect of different disinfectant systems on the dimensional stability of commonly used irreversible hydrocolloid and addition silicone impression materials from developing countries as compared to materials from developed countries. Material and methods: Disinfectant systems used were glutaraldehyde, sodium hypochlorite and ultraviolet chamber. The stability after disinfection of commonly used alginate and addition silicone of native origin (Algin-Gum & Ad-Sil was compared with similar impression materials from developed countries (Vignette and Aquasil and results compared. A CAD/CAM manufactured stainless steel die simulating maxilla with four metal studs at canine and molar region was used. Impressions were made and disinfected after rinsing and drying and casts poured. The cross arch distance, interabutment distance and the occluso-gingival length of the studs was measured under traveling microscope and observations were recorded and compared. ANOVA test and Bonferroni test was applied. Results: An increase in the interabutment and cross arch distance and decrease in occluso-gingival height was seen in the casts obtained. Glutaraldehyde immersion showed variation in the interabutment and cross arch distance for all materials studied. Ultraviolet chamber and sodium hypochlorite produced best results. Dimensional stability of impression materials like Vignette, Algin-Gum & Aquasil was found to within clinically acceptable limits after disinfection while maximum deviation was seen with Algin-Gum. Conclusion: Evaluated materials can be safely disinfected with sodium hypochlorite and ultraviolet chamber. Addition silicone of native origin is at par with impression materials from developed countries but same cannot be said about alginate. Keywords: Dimensional stability, Immersion systems, Ultraviolet chamber, Addition silicone, Alginate, Sodium hypochlorite, Glutaraldehyde

  5. Bacterial, fungal and yeast contamination in six brands of irreversible hydrocolloid impression materials Contaminação por bactérias, fungos e leveduras em seis marcas comerciais de materiais de moldagem à base de hidrocolóide irreversível

    Directory of Open Access Journals (Sweden)

    Luciana Assirati Casemiro

    2007-06-01

    Full Text Available This study assessed the level of contamination of six commercially available irreversible hydrocolloids (two containing chlorhexidine and identified the contamination present in the materials. Petri dishes containing selective and enriched culture media were inoculated with alginate powder (0.06 g, in triplicate. After incubation (37°C/7 days, the colony-forming units (CFU were counted and Gram stained. Biochemical identification of the different morphotypes was also performed. The contamination levels for the materials were: Jeltrate - 389 CFU/g; Jeltrate Plus - 516 CFU/g; Jeltrate Chromatic - 135 CFU/g; Hydrogum - 1,455 CFU/g; Kromopan - 840 CFU/g; and Greengel - 59 CFU/g. Gram staining revealed the presence of Gram-positive bacillus and Gram-positive cocci. The bacteria Staphylococcus epidermidis, Bacillus subtilis, Bacillus sp., Bacillus coagulans, Bacillus licheniformis, Bacillus cereus, Micrococcus luteus, and Nocardia sp.; the filamentous fungi Aspergillus niger, Aspergillus flavus, Rhizopus sp., Neurospora sp.; and the yeast Candida sp. were isolated. The contamination detected in the impression materials points out the need for adopting measures to improve the microbiological quality of these materials. The use of contaminated materials in the oral cavity goes against the basic principles for controlling cross-contamination and may represent a risk for debilitated or immunocompromised patients.Este estudo avaliou o nível de contaminação de seis marcas comerciais de alginato (duas contendo clorexidina e identificou a contaminação presente nesses materiais. Alíquotas de alginato (0,06 g foram semeadas em meios de cultura seletivos e enriquecidos, em triplicata. Após incubação (37°C/7 dias, as unidades formadoras de colônia (UFC foram contadas e foram realizadas as identificações morfotintorial (Gram e bioquímica. Os níveis de contaminação dos materiais foram: Jeltrate - 389 UFC/g; Jeltrate Plus - 516 UFC/g; Jeltrate

  6. Effect of Pouring Time and Storage Temperature on Dimensional Stability of Casts Made from Irreversible Hydrocolloid

    Directory of Open Access Journals (Sweden)

    M. Farzin

    2010-12-01

    Full Text Available Objective: The aim of this study was to evaluate the dimensional stability of casts made from an alginate impression material poured immediately and stored after specific periods.Materials and Methods: The common alginate used in Iran (Super; Iralgin, Golchai Co.,Tehran, Iran was tested. A master model was mounted on a special device and used to obtain the impressions. These impressions were stored at 23°C (SD=1 and 4°C (SD=1 in100% relative humidity, then poured with gypsum immediately and again after 12, 25, 45 and 60 minutes. The casts were measured with a traveling microscope with the precision of 0.5 micrometer.Results: The dimensional stability of the alginate and impressions were both significantly time and temperature dependent. The impressions were dimensionally stable significantly until 12 minutes of storage at room temperature and until 45 minutes of storage at 4°C(SD=1.Conclusion: The dimensional stability of the alginate impressions was influenced by the storage time and environment temperature, but a humid environment and 4°C (SD=1temperature may delay the pouring.

  7. Functional and Preliminary Characterisation of Hydrocolloid from Tamarillo (Solanum betaceum Cav. Puree

    Directory of Open Access Journals (Sweden)

    Kharidah Muhammad

    2012-06-01

    Full Text Available Hydrocolloid from tamarillo (Solanum betaceum Cav. puree was extracted using water and characterised for the first time. Proximate compositions of the extracted hydrocolloid were also determined. Functional characteristics such as water-holding capacity, oil-holding capacity, emulsifying activity, emulsion stability, foaming capacity and stability of the hydrocolloid were evaluated in comparison to that of commercial hydrocolloids. Its functional groups and degree of esterification were determined using Fourier Transform Infrared (FT-IR spectroscopy. Monosaccharide profiling was done using reverse-phase high pressure liquid chromatography (RP-HPLC. Screening of various fruits for high hydrocolloid yield after water extraction resulted in tamarillo giving the highest yield. The yield on dry weight basis was 8.30%. The hydrocolloid constituted of 0.83% starch, 21.18% protein and 66.48% dietary fibre with 49.47% degree of esterification and the monosaccharides identified were mannose, ribose, rhamnose, galacturonic acid, glucose, galactose, xylose and arabinose. Higher oil-holding capacity, emulsifying activity and emulsion stability compared to commercial hydrocolloids propose its possible application as a food emulsifier and bile acid binder. Foaming capacity of 32.19% and good foam stabilisation (79.36% of initial foam volume after 2 h of foam formation suggest its promising application in frothy beverages and other foam based food products. These findings suggest that water-extracted tamarillo hydrocolloid can be utilised as an alternative to low methoxyl pectin.

  8. Determination of bound and unbound water in dental alginate irreversible hydrocolloid by nuclear magnetic resonance spectroscopy.

    Science.gov (United States)

    Fellows, C M; Thomas, G A

    2009-04-01

    Alginate materials are considered unsuitable for precise fixed prosthetic rehabilitation due to their tendency to undergo spontaneous syneresis. Commercial alginate impression materials were investigated using Nuclear Magnetic Resonance (NMR) Spectroscopy to probe the relation between changes in the microscopic water environment and dimensional change to obtain a better understanding of spontaneous syneresis. NMR was used to measure the spin-lattice relaxation times (T(1)) of (1)H nuclei in water in alginate matrices to characterize changes in gel structure over time. These results were related to the dimensional stabilities of the alginate impression materials, their chemical compositions, and the Moisture Sorption Isotherms (MSI) obtained by incubation at fixed relative humidities. The rate of change of T(1) with time was found to be a better predictor of dimensional stability than MSI. The greatest dimensional stability for the alginate powders investigated was associated with a high filler:alginate ratio and a high Ca:Na ratio. Nuclear magnetic resonance spectroscopy may used to measure changes in alginate impression materials under conditions where no dimensional change can be observed directly. Changes occurred rapidly even at 100% humidity, suggesting the dimensional stability of alginate impression materials is partially independent of the rate of dehydration. The results may open a way to formulate alginate impression materials more suitable for precise fabrication of dental prostheses.

  9. Simplified Prosthetic Rehabilitation of a Patient after Oral Cancer Removal.

    Science.gov (United States)

    Kranjčić, Josip; Džakula, Nikola; Vojvodić, Denis

    2016-09-01

    The treatment of patients with oral cancer is complex: a multidisciplinary approach needs to be taken and maxillofacial and oral surgeons, an oncologist, a prosthodontist should be included, and a psychologist is often needed. This case report describes the prosthetic rehabilitation of a patient after surgical removal of oral cancer with obturator prosthesis. Resection cavity was located in central part of the hard palate and the condition belonged to Aramany class 3 maxillary defects. The two-step impression technique of denture bearing area was used and the resection of cavity was performed. A primary impression-the impression of denture bearing area was made using irreversible hydrocolloid material, while the second impression - the impression of resection cavity was made using condensation silicone material and obturator prosthesis framework. The obturator prosthesis replaced lost teeth, improved oral function and esthetics at minimal costs.

  10. Simplified Prosthetic Rehabilitation of a Patient after Oral Cancer Removal

    Directory of Open Access Journals (Sweden)

    Nikola Džakula

    2016-01-01

    Full Text Available The treatment of patients with oral cancer is complex: a multidisciplinary approach needs to be taken and maxillofacial and oral surgeons, an oncologist, a prosthodontist should be included, and a psychologist is often needed. This case report describes the prosthetic rehabilitation of a patient after surgical removal of oral cancer with obturator prosthesis. Resection cavity was located in central part of the hard palate and the condition belonged to Aramany class 3 maxillary defects. The two-step impression technique of denture bearing area and the resection cavity was performed. A primary impression- the impression of denture bearing area was made using irreversible hydrocolloid material, while the second impression – the impression of resection cavity was made using condensation silicone material and obturator prosthesis framework. The obturator prosthesis replaced lost teeth, improved oral function and esthetics at minimal costs.

  11. Seaweed hydrocolloid production: an update on enzyme assisted extraction and modification technologies.

    Science.gov (United States)

    Rhein-Knudsen, Nanna; Ale, Marcel Tutor; Meyer, Anne S

    2015-05-27

    Agar, alginate, and carrageenans are high-value seaweed hydrocolloids, which are used as gelation and thickening agents in different food, pharmaceutical, and biotechnological applications. The annual global production of these hydrocolloids has recently reached 100,000 tons with a gross market value just above US$ 1.1 billion. The techno-functional properties of the seaweed polysaccharides depend strictly on their unique structural make-up, notably degree and position of sulfation and presence of anhydro-bridges. Classical extraction techniques include hot alkali treatments, but recent research has shown promising results with enzymes. Current methods mainly involve use of commercially available enzyme mixtures developed for terrestrial plant material processing. Application of seaweed polysaccharide targeted enzymes allows for selective extraction at mild conditions as well as tailor-made modifications of the hydrocolloids to obtain specific functionalities. This review provides an update of the detailed structural features of κ-, ι-, λ-carrageenans, agars, and alginate, and a thorough discussion of enzyme assisted extraction and processing techniques for these hydrocolloids.

  12. Effect of Hydrocolloids and Emulsifiers on Baking Quality of Composite Cassava-Maize-Wheat Breads

    Directory of Open Access Journals (Sweden)

    Maria Eduardo

    2014-01-01

    Full Text Available Cassava is widely available worldwide but bread quality is impaired when cassava is used in the bread formulation. To overcome this problem, different improvers were tested in the preparation of composite cassava-maize-wheat (CMW breads. Emulsifiers, diacetyl tartic acid ester of monoglycerides (DATEM, sodium stearoyl-2-lactylate (SSL, and lecithin (LC; and hydrocolloids, carboxymethylcellulose (CMC and high-methylated pectin (HM pectin were added during dough preparation of the composite flours (cassava-maize-wheat, 40 : 10 : 50. Each emulsifier was tested in combination with the hydrocolloids at levels of 0.1, 0.3, and 0.5% while hydrocolloids were used at a level of 3%. Bread quality attributes such as specific loaf volume, crust colour, crumb moisture, and firmness were measured. The specific volume of the fresh breads significantly improved with the addition of hydrocolloids (7.5 and 13% and in combination with emulsifiers (from 7.9 to 27% compared with bread produced without improvers. A significant improvement of brownness index and firmness of the composite flours breads was achieved with the addition of hydrocolloids and emulsifiers. The results show that emulsifiers and hydrocolloids can significantly improve the baking quality of CMW breads and thereby enhance the potential for using locally produced flours in bread baking.

  13. Sulcus reproduction with elastomeric impression materials: a new in vitro testing method.

    Science.gov (United States)

    Finger, Werner J; Kurokawa, Rie; Takahashi, Hidekazu; Komatsu, Masashi

    2008-12-01

    Aim of this study was to investigate the depth reproduction of differently wide sulci with elastomeric impression materials by single- and double-mix techniques using a tooth and sulcus model, simulating clinical conditions. Impressions with one vinyl polysiloxane (VPS; FLE), two polyethers (PE; IMP and P2), and one hybrid VPS/PE elastomer (FUS) were taken from a truncated steel cone with a circumferential 2 mm deep sulcus, 50, 100 or 200 microm wide. The "root surface" was in steel and the "periodontal tissue" in reversible hydrocolloid. Single-mix impressions were taken with light-body (L) or monophase (M) pastes, double-mix impressions with L as syringe and M or heavy-body (H) as tray materials (n=8). Sulcus reproduction was determined by 3D laser topography of impressions at eight locations, 45 degrees apart. Statistical data analysis by ANOVA and multiple comparison tests (pimpression materials only: FLE=IMP>FUS=P2. At 50 and 100 microm width, significant differences were found between materials (IMP>FUS=FLE>P2) and techniques (L+H=L+M>M>L). The sulcus model is considered useful for screening evaluation of elastomeric impression materials ability to reproduce narrow sulci. All tested materials and techniques reproduced 200 microm wide sulci to almost nominal depth. Irrespective of the impression technique used, IMP showed the best penetration ability in 50 and 100 microm sulci. Double-mix techniques are more suitable to reproduce narrow sulci than single-mix techniques.

  14. Hydrocolloid occlusion for the treatment of neurovascular corns

    DEFF Research Database (Denmark)

    Petersen, Lars Jelstrup; Beck, Jan Walther; Reumert, L N

    1991-01-01

    The goal of this study was to determine the effect of hydrocolloid occlusion on neurovascular corns. The design was an observer-blinded, randomized, controlled study. Thirty consecutive patients participated in the trial. The patients received curettage alone or curettage with hydrocolloid...... occlusion. Six treatments were given over 12 weeks. A follow-up examination was performed 3 months after termination of the trial. Outcome measures were the size of the corns, a discomfort score, and an overall judgment of the trial. The results demonstrated no benefit of occlusion for symptoms or signs...... of neurovascular corns. The patients treated with occlusion were, however, generally more satisfied than the conventional group....

  15. Seaweed Hydrocolloid Production: An Update on Enzyme Assisted Extraction and Modification Technologies

    Directory of Open Access Journals (Sweden)

    Nanna Rhein-Knudsen

    2015-05-01

    Full Text Available Agar, alginate, and carrageenans are high-value seaweed hydrocolloids, which are used as gelation and thickening agents in different food, pharmaceutical, and biotechnological applications. The annual global production of these hydrocolloids has recently reached 100,000 tons with a gross market value just above US$ 1.1 billion. The techno-functional properties of the seaweed polysaccharides depend strictly on their unique structural make-up, notably degree and position of sulfation and presence of anhydro-bridges. Classical extraction techniques include hot alkali treatments, but recent research has shown promising results with enzymes. Current methods mainly involve use of commercially available enzyme mixtures developed for terrestrial plant material processing. Application of seaweed polysaccharide targeted enzymes allows for selective extraction at mild conditions as well as tailor-made modifications of the hydrocolloids to obtain specific functionalities. This review provides an update of the detailed structural features of κ-, ι-, λ-carrageenans, agars, and alginate, and a thorough discussion of enzyme assisted extraction and processing techniques for these hydrocolloids.

  16. Production, properties, and applications of hydrocolloid cellular solids.

    Science.gov (United States)

    Nussinovitch, Amos

    2005-02-01

    Many common synthetic and edible materials are, in fact, cellular solids. When classifying the structure of cellular solids, a few variables, such as open vs. closed cells, flexible vs. brittle cell walls, cell-size distribution, cell-wall thickness, cell shape, the uniformity of the structure of the cellular solid and the different scales of length are taken into account. Compressive stress-strain relationships of most cellular solids can be easily identified according to their characteristic sigmoid shape, reflecting three deformation mechanisms: (i) elastic distortion under small strains, (ii) collapse and/or fracture of the cell walls, and (iii) densification. Various techniques are used to produce hydrocolloid (gum) cellular solids. The products of these include (i) sponges, obtained when the drying gel contains the occasionally produced gas bubbles; (ii) sponges produced by the immobilization of microorganisms; (iii) solid foams produced by drying foamed solutions or gels containing oils, and (iv) hydrocolloid sponges produced by enzymatic reactions. The porosity of the manufactured cellular solid is subject to change and depends on its composition and the processing technique. The porosity is controlled by a range of methods and the resulting surface structures can be investigated by microscopy and analyzed using fractal methods. Models used to describe stress-strain behaviors of hydrocolloid cellular solids as well as multilayered products and composites are discussed in detail in this manuscript. Hydrocolloid cellular solids have numerous purposes, simple and complex, ranging from dried texturized fruits to carriers of vitamins and other essential micronutrients. They can also be used to control the acoustic response of specific dry food products, and have a great potential for future use in countless different fields, from novel foods and packaging to medicine and medical care, daily commodities, farming and agriculture, and the environmental, chemical

  17. Identification and characterization of hydrocolloid from Cordia myxa leaf.

    Science.gov (United States)

    Samavati, Vahid; Lorestani, Mohammad; Joolazadeh, Sajjad

    2014-04-01

    Hot water extraction technique was employed to extract the hydrocolloid from Cordia myxa leaf (PCM). The optimal conditions for extraction of PCM were determined using response surface methodology. A Box-Behnken design (BBD) was applied to evaluate the effects of three independent variables (extraction time (X1: 1-4 h), extraction temperature (X2: 55-95 °C), and water to raw material ratio (X3: 5-30 ml/g) on the extraction yield of PCM. The content of moisture, water-soluble and water-insoluble ash, crude protein and total phenol were determined in the extracted hydrocolloid by standard methods. The maximum hydrocolloid extraction yield (9.501±0.15%) was achieved by using extraction time of 4.94 h, extraction temperature of 94.91 °C and water to raw material ratio of 21.74 ml/g. The contents of moisture, crude protein, water-soluble and water-insoluble ash and total phenol were 21.63±0.94%, 14.27±0.55%, 3.07±0.16% and 2.61±0.19 mg galic acid/g, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Fortification of yogurt with oat hydrocolloid

    Science.gov (United States)

    C-Trim 30, an oat hydrocolloid was added to milk such that fermented yogurt had 0, 0.75, 1.5, 2.25, and 3 g ß-glucan per serving. The fermentation rate and physical characteristics of yogurt were studied. Lactose fermentation was not inhibited by the addition of C-Trim. All yogurt mix reached the...

  19. Evaluation of setting time and flow properties of self-synthesize alginate impressions

    Science.gov (United States)

    Halim, Calista; Cahyanto, Arief; Sriwidodo, Harsatiningsih, Zulia

    2018-02-01

    Alginate is an elastic hydrocolloid dental impression materials to obtain negative reproduction of oral mucosa such as to record soft-tissue and occlusal relationships. The aim of the present study was to synthesize alginate and to determine the setting time and flow properties. There were five groups of alginate consisted of fifty samples self-synthesize alginate and commercial alginate impression product. Fifty samples were divided according to two tests, each twenty-five samples for setting time and flow test. Setting time test was recorded in the s unit, meanwhile, flow test was recorded in the mm2 unit. The fastest setting time result was in the group three (148.8 s) and the latest was group fours). The highest flow test result was in the group three (69.70 mm2) and the lowest was group one (58.34 mm2). Results were analyzed statistically by one way ANOVA (α= 0.05), showed that there was a statistical significance of setting time while no statistical significance of flow properties between self-synthesize alginate and alginate impression product. In conclusion, the alginate impression was successfully self-synthesized and variation composition gives influence toward setting time and flow properties. The most resemble setting time of control group is group three. The most resemble flow of control group is group four.

  20. Extension shelf life of batte by using hydrocolloids and gamma irradiation

    Directory of Open Access Journals (Sweden)

    Mervat M. Anwar

    2015-10-01

    Full Text Available Batte (is baked french one of the most baked coated most prevalent in the markets after the cake wrapping. Batte exposed generally two types of corruption which is occurring phenomenon of (anti-staling and corruption microbial (molds. In this study produced batte with an attempt to prolong the period of its validity by addition 1.5% hydrocolloids, (which is 0.5% sodium alginate, 0.5% k-carrageenan and 0.5% hydroxyl propyl methylcellulose (HPMC to hard wheat flour 72% (HWF to improve materials for mellowness and anti-staling, whereas batte exposed to gamma irradiation at doses 0.5, 1, 1.5, 2, 3 and 5 kGy to decrease microbial load. Hydrocolloids at 1.5% improved the rheological properties of dough farinogragh and aextensograph parameters. The hydrocolloids increase flexibility, rubber and freshness of batte to 24 days compared to 8 days in control sample. Thiobarbituric acid (T.B.A values at the end of storage at room temperature (ranged to 0.253–0.352 mg malonaldehyde/kg that were less than these mentioned by the Egyptian Standard. Also, gamma irradiation reduced the total bacterial count of batte product. Sensory evaluation of produced batte was done. The addition of 1.5% hydrocolloids and exposed to gamma irradiation had higher freshness and increase shelf-life for 20, 25, 30, 35 and 40 days against only 15 days for control sample.

  1. Face-masks for facial atopic eczema: consider a hydrocolloid dressing.

    Science.gov (United States)

    Rademaker, Marius

    2013-08-01

    Facial involvement of atopic eczema in young children can be difficult to manage. Chronic scratching and rubbing, combined with parental reluctance to use topical corticosteroids on the face, often results in recalcitrant facial eczema. While wet wraps are a useful management option for moderate/severe atopic eczema involving the trunk and limbs they are difficult to use on the face. We describe the use of a face-mask using a widely available adhesive hydrocolloid dressing (DuoDerm extra thin) in three children with recalcitrant facial atopic eczema. Symptomatic control of itch or soreness was obtained within hours and the facial atopic eczema was markedly improved by 7 days. The face-masks were easy to apply, each lasting 1-4 days. One patient had a single adjuvant application of a potent topical corticosteroid under the hydrocolloid dressing. All three patients had long remissions (greater than 3 months) of their facial eczema, although all continued to have significant eczema involving their trunk and limbs. Face-masks made from hydrocolloid dressings, with or without topical corticosteroids, are worth considering in children with recalcitrant facial eczema. © 2012 The Author. Australasian Journal of Dermatology © 2012 The Australasian College of Dermatologists.

  2. Hydrocolloids Decrease the Digestibility of Corn Starch, Soy Protein, and Skim Milk and the Antioxidant Capacity of Grape Juice.

    Science.gov (United States)

    Yi, Yue; Jeon, Hyeong-Ju; Yoon, Sun; Lee, Seung-Min

    2015-12-01

    Hydrocolloids have many applications in foods including their use in dysphagia diets. We aimed to evaluate whether hydrocolloids in foods affect the digestibility of starch and protein, and their effects on antioxidant capacity. The thickening hydrocolloids: locust bean gum and carboxymethyl cellulose, and the gel-forming agents: agar agar, konjac-glucomannan, and Hot & Soft Plus were blended with corn starch and soy protein, skim milk, or grape juice and were examined for their in vitro-digestability by comparing the reducing sugar and trichloroacetic acid (TCA)-soluble peptide, for antioxidant capacity by total polyphenol contents and the 2,2-diphenyl-1-picrylhydrazyl radical scavenging activity. The hydrocolloids resulted in a decrease in starch digestibility with the gel-forming agents. Hydrocolloids diminished TCA-soluble peptides in skim milk compared to soy protein with the exception of locust bean gum and decreased free radical scavenging capacities and total phenolic contents in grape juice. Our findings may provide evidence for the use of hydro-colloids for people at risk of nutritional deficiencies such as dysphagia patients.

  3. Evaluation of dimensional stability of Iralgin and Alginoplast alginates after disinfection by sodium hypochlorite (5.2% with immersion and spraying methods

    Directory of Open Access Journals (Sweden)

    Vojdani M

    2006-01-01

    Full Text Available Background and Aim: Infection control is an integral part of dentistry and dental impressions are considered an important issue in cross contamination. The aim of this study was to investigate the dimensional stability of two irreversible hydrocolloid materials, Alginoplast and Iralgin after disinfection with 5.2% sodium hypochlorite, used with immersion and spraying methods. Material and Methods: In this experimental study, impressions were made of a master mandibular arch (Typodont containing three stainless steel inserts on the occlucal surface of both mandibular first molars and in the lingual surface of the mandibular central incisors, which served as reference marks for making measurements. Two types of irreversible hydrocolloid (Iralgin and Alginoplast were tested. 5.2% sodium hypochlorite was used in two methods of spraying and immersion to disinfect the samples. The control group was not disinfected. Casts were made of type III gypsum. Stone casts were measured with a Nikon profile projector.Kruskall-Wallis and Mann-Witney test were used for statistical analysis using p<0.05 as the limit of significance. Results: Casts prepared from Alginoplast disinfected by spraying method, were 0.38 % larger in anteroposterior and 0.06% smaller in cross arch dimensions, whereas those prepared from Alginoplast immersed in hypochlorite were 0.47% larger in anteroposterior and 0.11% smaller in cross arch dimensions. Casts made from Iralgin were smaller after both methods of disinfecting, (0.01% smaller in anteroposterior and 0.001% smaller in cross-arch dimensions after spraying and 0.04% smaller in anteroposterior and 0.03% smaller in cross-arch dimensions after immersing in sodium hypochlorite. Conclusion: Alginoplast and Iralgin impressions can be immersed or sprayed for disinfection without compromising the accuracy needed for diagnostic and opposing casts, as well as removable partial denture construction.

  4. Improvement of physical properties of gluten-free steamed cake based on black waxy rice flour using different hydrocolloids.

    Science.gov (United States)

    Itthivadhanapong, Pimchada; Jantathai, Srinual; Schleining, Gerhard

    2016-06-01

    This study aimed to compare the effects of 1 % addition of four selected hydrocolloids (xanthan, guar, hypdroxypropylmethylcellulose and carrageenan) on quality characteristics of batter and of black waxy rice steamed cake compared to a control without hydrocolloids. Dynamic frequency sweeps of the batters at 25 °C indicated that all formulations exhibited gel-like behaviour with storage moduli (G') higher than loss moduli (G″). Hydrocolloids increased the apparent viscosity and the thixotropic behaviour, depending on the type of hydrocolloids. Xanthan had the greatest effects on both moduli, whereas carrageenan had the smallest effects. During a storage period of 4 days the cakes with xanthan remained softer than control samples. The overall acceptability of cake with xanthan and guar were higher than control. This study is the first report on using black waxy rice flour as a main raw material in gluten free cake. The results of this study provided useful information for selection hydrocolloids as ingredients that can help to improve the physical properties of waxy rice steamed cake.

  5. Effects of different hydrocolloids on properties of gluten-free bread based on small broken rice berry flour.

    Science.gov (United States)

    Numfon, Rakkhumkaew

    2017-06-01

    Gluten-free bread formulations based on small broken rice berry using various types of hydrocolloids (xanthan gum, guar gum, and locust bean gum) at different concentrations (0, 1, 1.5, and 2 g/100 g) were tested in this study. The effects of hydrocolloid addition on the pasting properties of flour were also investigated, including the quality parameters of the breads. The pasting properties of small broken rice berry flour incorporated with guar gum were most affected. Gluten-free bread containing hydrocolloid showed improved qualities in terms of loaf specific volume, texture, sensory values, and microstructure. A 1 g/100 g of hydrocolloid addition was sufficient to improve the physical and chemical qualities of bread. The highest score of all attributes from the sensory evaluation was obtained by gluten-free bread containing 1 g/100 g guar gum.

  6. The effect of pouring time on the dimensional stability of casts made from conventional and extended-pour irreversible hydrocolloids by 3D modelling

    Directory of Open Access Journals (Sweden)

    Hasan Ö. Gümüş

    2015-09-01

    Conclusion: All of the conventional and extended-pour impression materials tested in this study can be poured up to 24 hours with accuracy, if impressions are correctly stored. Extended-pour impression materials (ColorChange, Hydrogum 5, and Hydrocolor 5 can be poured up to 120 hours, if stored correctly.

  7. Study of rheology and friction factor of natural food hydrocolloid gels

    Directory of Open Access Journals (Sweden)

    Vojtěch Kumbár

    2017-01-01

    Full Text Available Differences in the rheology and friction factor of natural food hydrocolloid gels were studied in this paper. The practical importance of the knowledge of the rheological parameters is quite evident. The experimental data were carried out using a concentric cylinder rotary viscometer. It was prepared 1% hydrocolloid solutions (hydrogels. Hydrogels of the natural gums extracted from the seeds of the plants and plant tubers have been used - carob gum (from the seeds of Ceratonia siliqua, guar gum (from the seeds of Cyamopsis tetragonoloba and tara gum (from the seeds of Caesalpinia spinosa. Rheological behaviour has non-Newtonian pseudoplastic character and the flow curves were fitted using the Otswald - de Waele (power law model and Herschel - Bulkley model. The hydrogels exhibit shear thinning behaviour. The meaning of the rheological parameters on the friction factors during flow of hydrocolloid gels in the tube has been shown. Information on time dependent behaviour of tested liquids has been also obtained. Time dependent curves were fitted by the Gaussian model. Preliminary results obtained for a constant shear rate showed the thixotropic and time-dependent behaviour of the hydrogels. These parameters can be especially used in much software dealing with a numerical simulation of the flow problems.

  8. Corrigendum to “Rheological properties of agar and carrageenan from Ghanaian red seaweeds” [Food Hydrocolloids 63 (2017) 50–58

    DEFF Research Database (Denmark)

    Rhein-Knudsen, Nanna; Ale, Marcel Tutor; Ajalloueian, Fatemeh

    2018-01-01

    . G., Penninkhof, B., Rudolph, B., & De Ruiter, G. A. (1999). A novel high-performance anion-exchange chromatographic method for the analysis of carrageenans and agars containing 3,6-anhydrogalactose. Analytical Biochemistry, 268, 213-222. Table 3 Overview of seaweed type (hydrocolloid source......), hydrocolloid extraction method (direct water-extraction or after alkali treatment), hydrocolloid and monomer1 yields, and sulfate levels [data given as means ± SD]. Different roman superscript letters indicate significant differences (P agar yields, monosaccharides...

  9. Influence of different hydrocolloids on dough thermo-mechanical properties and in vitro starch digestibility of gluten-free steamed bread based on potato flour.

    Science.gov (United States)

    Liu, Xingli; Mu, Taihua; Sun, Hongnan; Zhang, Miao; Chen, Jingwang; Fauconnier, Marie Laure

    2018-01-15

    The effects of hydrocolloids (hydroxypropylmethylcellulose (HPMC), Carboxymethylcellulose (CMC), xanthan gum (XG), and apple pectin (AP)) at different concentrations on dough thermo-mechanical properties and in vitro starch digestibility of gluten-free potato steamed bread were investigated. Results showed that hydrocolloids addition significantly increased the gelatinization temperature (from 52.0 to 64.2°C) and water absorption (from 56.22 to 66.50%) of potato dough. Moreover, hydrocolloids may be interacted with protein and starch, the density of potato protein bands was decreased by hydrocolloids addition, the reason might be that higher molecular weight complexes might be formed between proteins-hydrocolloids or proteins-proteins, thus change the protein solubility. Furthermore, steamed breads with hydrocolloids presented higher specific volume and lower hardness, and the rapidly digestible starch and estimated glycemic index were significantly decreased from 45.51 to 20.64, from 69.54 to 55.17, respectively. In conclusion, HPMC and XG could be used as improvers in the gluten-free potato steamed bread. Copyright © 2017. Published by Elsevier Ltd.

  10. Effect of hydrocolloids and pretreatments on the keeping quality of minced fillets of whiting and cod during frozen storage

    NARCIS (Netherlands)

    Ponte, da D.J.B.

    1986-01-01

    The present study examines the effects of additions of hydrocolloids and pretreatments (precooking and irradiation) on the stability of minced fillets of whiting and cod during frozen storage (-18°C).

    Some hydrocolloids (Xanthan gum, alginates, carboxymethyl celluloses and Iota and Lambda

  11. The Effect of Freezing and Hydrocolloids on the Physical Parameters of Strawberry Mass-Based Desserts

    Directory of Open Access Journals (Sweden)

    Boča Sigita

    2014-07-01

    Full Text Available The aim of the study was to evaluate the effect of freezing, thickening and storage on the physical properties of the strawberry desserts made with addition of various hydrocolloids. The strawberry cultivars ‘Polka’, ‘Honeoye’, and ‘Senga Sengana’ harvested in Latvia were used in the study. The strawberries were processed in a blender for obtaining a homogenous mass. The strawberry mass was analyzed fresh and after storage at -18 °C. Both fresh and frozen strawberry mass samples with added gelatine, xanthan gum, and sodium carboxymethyl cellulose were whisked until obtaining dessert. For determination of the optimum hydrocolloid amount, sensory evaluation was done using a five-point hedonic scale. Moisture, soluble solids content, density, and pH of the product were determined. Apparent viscosity was measured using a rotational viscometer DV–III Ultra. Consistency of the dessert during its storage was evaluated using a texture analyser TA.XT.plus. The results of sensory evaluation allow concluding that in order to provide the most acceptable consistency, colour, and taste of strawberry dessert, the optimum quantity of carboxymethyl cellulose and xanthan gum to be added is 0.6% and that of gelatine is 6%. During freezing, the soluble solids content and pH level decreased in the strawberry mass, whereas the addition of hydrocolloids increased these values. The moisture content in strawberry puree, in its turn, as a result of freezing increased under the influence of syneresis, but added hydrocolloids, on the contrary, decreased this influence. Also the viscosity and consistency of the strawberry puree prepared from the researched cultivars decreased under the influence of freezing, whereas the addition of hydrocolloids increased both the values, making the strawberry dessert firmer. The research suggests that strawberry dessert with gelatine had the most pronounced changes during storage, but strawberry dessert with added xanthan

  12. Effects of Ultra-High Pressure Homogenization and Hydrocolloids on Physicochemical and Storage Properties of Soymilk.

    Science.gov (United States)

    Mukherjee, Dipaloke; Chang, Sam K C; Zhang, Yin; Mukherjee, Soma

    2017-10-01

    This study investigated the efficacy of ultra-high pressure homogenization (UHPH) in the presence or absence of added hydrocolloids for enhancing a range of physic-chemical properties of soymilk-which are important for extending shelf-life. Soymilk preparations containing different concentrations (0.01%, 0.02%, and 0.05%, w/v) of 2 different hydrocolloids (κ-carrageenan, κ-C, and gum Arabic, GA) were subjected to 3 different levels of UHPH (70, 140, and 210 MPa) and stored in sterilized containers at 4 °C. Emulsion properties of the soymilk preparations were analyzed over a period of 5 weeks. The results showed that soymilk with 0.05% κ-C had markedly improved storage properties, evident by significantly (P homogenization and addition of hydrocolloids to prevent aggregation of soymilk particles and the retention of antioxidant capacity. The results showed enhancement of the quality of soymilk during storage. The techniques developed can be adopted by the food industry. © 2017 Institute of Food Technologists®.

  13. Comparison of antimicrobial activities and compressive strength of alginate impression materials following disinfection procedure.

    Science.gov (United States)

    Alwahab, Zahraa

    2012-07-01

    This study investigated the effectiveness of disinfecting solution when incorporated into alginate powder instead of water against some microorganisms and on compressive strength of alginate. For measuring antimicrobial activity of alginate, 60 alginate specimens were prepared and divided into two groups: One with water incorporated in the mix (control) and the other with 0.2% chlorhexidine digluconate incorporated in the mix instead of water. The tested microorganisms were: gram +ve cocci, gram -ve bacilli and yeast (each group 10 samples). For measuring compressive strength, 20 specimens of alginate were divided into two groups: One with water incorporated in the mix (control) and the other with chlorhexidine incorporated in the mix. The statistical analysis of antimicrobial efficacy of alginate was performed with Mann-Whitney U-test, which revealed very high significant difference when comparing among groups (p 0.05). The incorporation of disinfecting agents into impression materials could serve an important role in dental laboratory infection control and it had no adverse effect on compressive strength of the hydrocolloid alginate. The risk of transmitting pathogenic microorganisms to dental laboratories via impression has been considered a topic of importance for a number of years.

  14. Comparison of hydrocolloid with conventional gauze dressing in prevention of wound infection after clean surgical procedures

    International Nuclear Information System (INIS)

    Khalique, M.S.; Shukr, I.; Khalique, A.B.

    2014-01-01

    To compare hydrocolloid with conventional gauze dressing in prevention of infections after clean surgical procedures. Study Design: Randomized controlled trial. Place and Duration of Study: Department of Surgery, CMH Rawalpindi from 22 Jan 2010 to 22 Aug 2010. Patients and Methods: A total of 400 patients undergoing clean surgical procedures were randomly allocated in two equal groups, A and B by lottery method. In group A. simple gauze dressing was applied after clean surgical procedures while in group B hydrocolloid dressing was used. On 7th post operative day, patients were observed for presence of infection. Results: Mean age of sample was 42.08 +-11.112 years. In group A out of 200 Patients, 14 (7.0%) while in group B 10 (5%) developed infection postoperatively (p=0.709). Conclusion: There is no difference in the rate of infection when using a gauze dressing or a hydrocolloid dressing after clean surgical procedure. (author)

  15. The Effect of Emulsifier and Hydrocolloid on Baking Expansion and Texture of Bread from Modified Cassava

    Directory of Open Access Journals (Sweden)

    Pudjihastuti Isti

    2018-01-01

    Full Text Available Indonesia has a very abundant cassava that can be used instead of wheat. Bread made from cassava is safe for celiac sufferers, in which cannot tolerate a protein called gluten found in wheat flour. However, bread from cassava has the disadvantage that it cannot inflate perfectly. Our research goal is to study the effect of emulsifier and hydrocolloid concentration as modifying agents on baking expansion and bread texture (hardness. The test level hedonic preference for bread products results from modified tapioca is also necessary to know the level of customer satisfaction. This study were conducted by three main stages, modification of cassava, baking process, and analyses. Modification of cassava starch was applied using combination of lactic acid solution and ultra violet (UV irradiation. Emulsifier (DATEM and hydrocolloid (xanthan gum were used in baking process. The addition of emulsifier and hydrocolloid can improve baking expansion. The addition of 7% emulsifiers on modified cassava can increase the volume of bread, taste, and texture so it can give greater satisfaction to consumers. Hydrocolloid can replace the function of gluten so the bread can inflate perfectly. The optimal composition of modified cassava in bread making is 25% of modified cassava and 75% of wheat flour. The low value of texture (hardness on bread made from modified cassava indicated a better performance in comparison with native cassava. Baking expansion and texture of the bread is influenced by the modification process. Furthermore, the comprehensive and optimum studies of modification need to be investigated.

  16. EFFECT of hydrocolloids on the quality evaluation of flour based noodles from Horse Chestnut

    Directory of Open Access Journals (Sweden)

    Rafiq Syed Insha

    2016-01-01

    Full Text Available The present study was focused to investigate the effects of hydrocolloids (guar gum and xanthan gum at additional levels (1%, 2% and 3% on the noodle characteristics prepared from horse chestnut flour. The qualities of noodles prepared from horse chestnut flour were compared with wheat flour based noodles in terms of cooking characteristics, textural and sensory properties. The hydrocolloid addition in noodles resulted in improvement of cooking and textural qualities in consistent to control sample. The incorporation of 3% gum significantly increased cooking properties and the firmness of cooked noodles. The results of the sensory evaluation based on a nine point hedonic scale revealed that apart from the control, noodles with 3% gum were acceptable to the panellists.

  17. The effectiveness of hydrocolloid dressings versus other dressings in the healing of pressure ulcers in adults and older adults: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Franciele Soares Pott

    2014-06-01

    Full Text Available OBJECTIVE: to evaluate the effectiveness of hydrocolloids in the healing of pressure ulcers in adult and older adult patients.METHOD: systematic review with meta-analysis, based on the recommendations of the Cochrane Handbook. The search was undertaken in the databases: Medical Literature Analysis and Retrieval System Online, Latin American and Caribbean Health Sciences Literature (LILACS, Cochrane Database, Cumulative Index to Nursing and Allied Health Literature, Web of Science and the Scientific Electronic Library Online.RESULTS: 646 primary studies were identified, 69 were evaluated and nine were selected, referring to the use of the hydrocolloid dressing in healing; of these, four studies allowed meta-analysis. There was no statistically significant difference between the hydrocolloid group and the foams group (p value=0.84; Odds Ratio 1.06, CI 95% 0.61-1.86. A slight superiority of the polyurethane dressings was observed in relation to the hydrocolloid dressings.CONCLUSION: the evidence is not sufficient to affirm whether the efficacy of hydrocolloid dressings is superior to that of other dressings. It is suggested that clinical randomized trials be undertaken so as to ascertain the efficacy of this intervention in the healing of pressure ulcers, in relation to other treatments.

  18. The Utilization of Canna Starch (Canna edulis Ker As A Alternative Hydrocolloid on The Manufacturing Process of Yogurt Drink

    Directory of Open Access Journals (Sweden)

    Ahmad Khoirul Umam

    2018-03-01

    Full Text Available Yogurt as a fermented dairy product has been providing several benefits for human health and appropriate for people with lactose intolerance. Recently, the consumption level of yogurt has significantly increased. Starch can be used as an alternative hydrocolloid in the manufacturing process of yogurt. Indonesian Canna edulis Ker contains 63.27% amylopectin that has the potential used as an alternative hydrocolloid. Amylopectin has a very high capability of the water holding capacity to increase the viscosity and maintain the stability of yogurt drink. The present research was to determine the additional effects of Canna starch as an alternative hydrocolloid on the physicochemical and sensory properties of the yogurt drink during storage. Concentrations of 0.1%, 0.2%, 0.3%, and 0.4% canna starch and 0.2% CMC (control were added to make yogurt. All treatments were carried out with four replications. Samples were refrigerated at 4oC for 24 hours and then analyzed for pH, titratable acidity, viscosity, syneresis, sedimentable fraction, and sensory properties. Data were analyzed by one way ANOVA, and followed by Duncan's multiple range test (DMRT. Data from the pH, titratable acidity, syneresis, sedimentable fraction, viscosity and sensory analyses obtained from the present study indicated that concentration of 0.1–0.4% (w/v Canna starch could be applicable in the manufacture of the yogurt drink. Furthermore, it was found that 0.1% (w/v of Canna starch selected as the best concentration could be used in yogurt manufacture process that resulted in similar sensory quality compared with CMC as commercial hydrocolloid.

  19. The Quality of Edible Film Made from Nile Tilapia (Oreochromis niloticus) Skin Gelatin with Addition of Different Type Seaweed Hydrocolloid

    Science.gov (United States)

    Deanti, H.; Hulu, J. M.; Setyaji, A.; Eliyanti, R. N.; Aliya, K.; Dewi, E. N.

    2018-02-01

    The functional properties of fish skin’s gelatin lower than mammals, hence the gelatin proteins needed a polysaccharides hydrocolloids to form a continuous and more cohesive network of edible film. Polysaccharides hydrocolloid (carrageenan, agar and alginate) containing phenol compounds was oxidized to be converted into quinone and it was expected to act as a cross linking agent. The purpose of this study was to determine the characteristics (thickness, tensile strength, elongation, solubility and water vapour transmition rate) of edible film made from nile tilapia skin gelatin by adding different type polyssacharide hydrocolloid. Edible film was made by mixture of gelatin 5 g and addition of carrageenan (C1), agar (C2), alginate (C3) concentration ; 0,5% (v/w), all the materials were poured into 100 ml destilled water that containing 10% glycerol (w/w). The solution was then heated on a hot plate stirer at 40°C for 30 min and dehydrated in a oven at 50°C. All data were analysed using ANAVA. Based on the result it can be seen that the addition of oxidized polisacarides hydrocolloid have a significant effect on tensile strength (TS), water vapor transmision rate, solubility and elongation at break properties, but did not in thickness. Edible film gelatin with the addition of alginate has better characteristics viewed by tensile strength (23.05 Kgf/cm2), water vapor transmission rate (0.61 gram/m2/hour) and thickness (0.16 mm) than carrageenan and agar.

  20. Hydrocolloid dressing in pediatric burns may decrease operative intervention rates.

    LENUS (Irish Health Repository)

    Martin, Fiachra T

    2010-03-01

    Partial-thickness scalds are the most common pediatric burn injury, and primary management consists of wound dressings to optimize the environment for reepithelialization. Operative intervention is reserved for burns that fail to heal using conservative methods. Worldwide, paraffin-based gauze (Jelonet) is the most common burn dressing; but literature suggests that it adheres to wounds and requires more frequent dressing change that may traumatize newly epithelialized surfaces. Hydrocolloid dressings (DuoDERM) provide an occlusive moist environment to optimize healing and are associated with less frequent dressing changes.

  1. Determination of the ‘apparent pKa’ of selected food hydrocolloids using ortho-toluidine blue

    NARCIS (Netherlands)

    Vleugels, Leo F.W.; Ricois, Stella; Voets, Ilja K.; Tuinier, Remco

    2018-01-01

    Charged food hydrocolloids provide structure and texture in manufactured foods by their organization and electrostatic interactions with other species and small ions. These electrostatic interactions depend on their actual charge density which cannot be predicted from pKa values of weakly charged

  2. Influence of hydrophilic polymers on functional properties and wound healing efficacy of hydrocolloid based wound dressings.

    Science.gov (United States)

    Jin, Sung Giu; Yousaf, Abid Mehmood; Kim, Kyeong Soo; Kim, Dong Wuk; Kim, Dong Shik; Kim, Jin Ki; Yong, Chul Soon; Youn, Yu Seok; Kim, Jong Oh; Choi, Han-Gon

    2016-03-30

    The purpose of this study was to investigate the influence of different hydrophilic polymers on the swelling, bioadhesion and mechanical strength of hydrocolloid wound dressings (HCDs) in order to provide an appropriate composition for a hydrocolloid wound dressing system. In this study, the HCDs were prepared with styrene-isoprene-styrene copolymer (SIS) and polyisobutylene (PIB) as the base using a hot melting method. Additionally, numerous SIS/PIB-based HCDs were prepared with six hydrophilic polymers, and their wound dressing properties were assessed. Finally, the wound healing efficacy of the selected formulations was compared to a commercial wound dressing. The swelling ratio, bioadhesive force and mechanical strengths of HCDs were increased in the order of sodium alginate>sodium CMC=poloxamer=HPMC>PVA=PVP, sodium alginate>sodium CMC=poloxamer>PVA>HPMC=PVP and sodium alginate≥PVA>PVP=HPMC=sodium CMC>poloxamer, respectively. Among the hydrophilic polymers tested, sodium alginate most enhanced the swelling capacity, bioadhesive force and mechanical strengths. Thus, the hydrophilic polymers played great role in the swelling, bioadhesion and mechanical strength of SIS/PIB-based HCDs. The HCD formulation composed of PIB, SIS, liquid paraffin and sodium alginate at the weight ratio of 20/25/12/43 gave better wound dressing properties and more excellent wound healing efficacy than the commercial wound dressing. Therefore, the novel HCD formulation could be a promising hydrocolloid system for wound dressings. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Early postoperative magnet application combined with hydrocolloid dressing for the treatment of earlobe keloids.

    Science.gov (United States)

    Park, Tae Hwan; Chang, Choong Hyun

    2013-04-01

    To prevent the recurrence of earlobe keloids after surgical removal, a reliable and safe postoperative treatment method is critical. To the authors' knowledge, no studies have elucidated the most effective postoperative dressing method for preventing the recurrence of earlobe keloids. This study aimed to compare keloid recurrence rates in patients whose keloids were dressed using conventional methods (plain gauze or a polyvinyl alcohol sponge) with those of a matched cohort of patients whose keloids were dressed using magnets combined with hydrocolloid materials. This observational case-control study compared a retrospective cohort of patients whose keloids were dressed using conventional methods with a matched prospective cohort of patients whose keloids were dressed using magnets combined with hydrocolloid materials. The study included patients with pathologically confirmed earlobe keloids that were surgically excised with primary closure. Patients 8 years of age or older underwent adjuvant pressure therapy with magnets at the study hospital. Patients were excluded from the study if they were unavailable for follow-up evaluation, if they had received additional adjuvant therapy during treatment, or if histologic confirmation of a keloid was not obtained. Matched-pair analysis was performed using the McNemar test. Treatment outcome was evaluated as recurrence or nonrecurrence. Overall, 9 (11.2%) of the 80 study patients experienced recurrence. The recurrence rate was significantly lower in the matched case group (2 of 40, 5%) than in the matched control group (7 of 40, 17.5%) during the follow-up period of 18 months (p=0.0253). The authors' novel dressing of magnets and hydrocolloid materials appears to be effective in reducing earlobe keloid recurrence. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to

  4. How the adoption of impression management goals alters impression formation.

    Science.gov (United States)

    Gibson, Bryan; Poposki, Elizabeth M

    2010-11-01

    Five experiments (N = 390) tested the hypothesis that adopting an impression management goal leads the impression manager to view an interaction partner as having less of the trait he or she is attempting to express. This hypothesis was confirmed for the impression management goals of appearing introverted, extraverted, smart, confident, and happy. Experiment 2 shows that adoption of the impression goal could alter judgments even when participants could not act on the goal. Experiment 3 provides evidence that adopting an impression management goal prompted a comparison mind-set and that this comparison mind-set activation mediated target judgments. Experiment 4 rules out a potential alternative explanation and provides more direct evidence that comparison of the impression manager's self-concept mediates the impression of the target. Experiment 5 eliminates a potential confound and extends the effect to another impression goal. These experiments highlight the dynamic interplay between impression management and impression formation.

  5. Process optimization for maximizing the rheology modifying properties of pectic hydrocolloids recovered from steam exploded biomass

    Science.gov (United States)

    Pectic hydrocolloids from citrus peel waste are highly functional molecules whose utility and application have expanded well beyond their traditional use in jams and jellies. They are now finding applications in health, pharmaceutical and personal care products as well as functioning as emulsifiers,...

  6. Controlling rheology and structure of sweet potato starch noodles with high broccoli powder content by hydrocolloids

    NARCIS (Netherlands)

    Silva, E.; Birkenhake, M.; Scholten, E.; Sagis, L.M.C.; Linden, van der E.

    2013-01-01

    Incorporating high volume fractions of broccoli powder in starch noodle dough has a major effect on its shear modulus, as a result of significant swelling of the broccoli particles. Several hydrocolloids with distinct water binding capacity (locust bean gum (LBG), guar gum, konjac glucomannan (KG),

  7. Irreversible social change

    NARCIS (Netherlands)

    Pols, A.J.K.; Romijn, H.A.; Collste, G.; Reuter, L.

    2014-01-01

    In this paper we evaluate how irreversible social change should be evaluated from an ethical perspective. First; we analyse the notion of irreversibility in general terms. We define a general notion of what makes a change irreversible; drawing on discussions in ecology and economics. This notion is

  8. Clinical and radiological findings in a case of non-syndromic oligodontia

    International Nuclear Information System (INIS)

    Jimenez Carrillo, Francisco J.

    2002-01-01

    A case of congenital absence of eleven dental pieces without association to syndromes is presented. An integral clinical examination of the patient's dental pieces has determined a case of oligodontia. Congenital absence of all permanent teeth described in the clinical examination are presented by orthopantomography radiography. Impressions with irreversible hydrocolloid are realized to complete the diagnostic. The case described of oligodontia has developed without presenting relation to some syndrome as Down syndrome or ectodermal dysplasia. Genes have played a very important role in the etiology of dental anomalies, according to the existing evidence. Mutation has been identified as the cause of dental defects in some of the genes in humans. The maxillary teeth developed in the marginal areas of the dental lamina have pretended to be the dental pieces more susceptible to be without form [es

  9. Accuracy of impressions with different impression materials in angulated implants.

    Science.gov (United States)

    Reddy, S; Prasad, K; Vakil, H; Jain, A; Chowdhary, R

    2013-01-01

    To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were placed parallel to each other and perpendicular to the plane of the cast. In the second and third group (control), all three implants were placed at 10° and 15 o angulation respectively to the long axis of the cast, tilting towards the centre. Impressions were made with polyvinyl siloxane and polyether impression materials in a special tray, using a open tray impression technique from the master casts. These impressions were poured to obtain test casts. Three reference distances were evaluated on each test cast by using a profile projector and compared with control groups to determine the effect of combined interaction of implant angulation and impression materials on the accuracy of implant resultant cast. Statistical analysis revealed no significant difference in dimensional accuracy of the resultant casts made from two different impression materials (polyvinyl siloxane and polyether) by closed tray impression technique in parallel and angulated implants. On the basis of the results of this study, the use of both the impression materials i.e., polyether and polyvinyl siloxane impression is recommended for impression making in parallel as well as angulated implants.

  10. Impression Cytology

    Directory of Open Access Journals (Sweden)

    Sevda Söker

    2007-01-01

    Full Text Available Impression cytology is fast, easy to perform, economical and non-invasive technique for the diagnosis of conjunctival eye diseases. Conjunctival impression cytology using cellulose acetate filter paper of the ocular surface epithelium with no side effects or contraindication. In this article, technique of conjunctival impression cytology is reviewed.

  11. Influence of Sugars, Modified Starches and Hydrocolloids Addition on Colour and Thermal Properties of Raspberry Cream Fillings

    Directory of Open Access Journals (Sweden)

    Pichler Anita

    2017-03-01

    Full Text Available This paper deals with the influence of the addition of sugars (sucrose, fructose and trehalose, modified starches (tapioca or waxy maize starch and hydrocolloids (karaya or guar gum on colour and thermal properties of raspberry cream fillings. In addition, the influence of the above-mentioned additives on the colour and thermal properties of raspberry cream fillings stored at room temperature over a period of 8 and 16 months was investigated. Results showed that the highest anthocyanin content and total phenolic content were detected in raspberry cream filling prepared with sucrose and trehalose in combination with guar gum. During storage, after 8 and 16 months at room temperature, anthocyanin content and total phenolic content decreased. Results also showed that the kind of sugar and added modified starches or hydrocolloids influenced the thermal properties of cream fillings. During storage, a decrease was observed in both freezing temperature as well as enthalpy of cream fillings.

  12. Accuracy of implant impressions without impression copings: a three-dimensional analysis.

    Science.gov (United States)

    Kwon, Joo-Hyun; Son, Yong-Ha; Han, Chong-Hyun; Kim, Sunjai

    2011-06-01

    Implant impressions without impression copings can be used for cement-retained implant restorations. A comparison of the accuracy of implant impressions with and without impression copings is needed. The purpose of this study was to evaluate and compare the dimensional accuracy of implant definitive casts that are fabricated by implant impressions with and without impression copings. An acrylic resin maxillary model was fabricated, and 3 implant replicas were secured in the right second premolar, first, and second molars. Two impression techniques were used to fabricate definitive casts (n=10). For the coping group (Group C), open tray impression copings were used for the final impressions. For the no-coping group (Group NC), cementable abutments were connected to the implant replicas, and final impressions were made assuming the abutments were prepared teeth. Computerized calculation of the centroids and long axes of the implant or stone abutment replicas was performed. The Mann-Whitney U test analyzed the amount of linear and rotational distortion between groups (α =.05). At the first molar site, Group NC showed significantly greater linear distortion along the Y-axis, with a small difference between the groups (Group C, 7.8 ± 7.4 μm; Group NC, 19.5 ± 12.2). At the second molar site, increased distortion was noted in Group NC for every linear and rotational variable, except for linear distortion along the Z-axis. Implant impression with open tray impression copings produced more accurate definitive casts than those fabricated without impression copings, especially those with greater inter-abutment distance. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  13. Hydrocolloid-Based Coatings are Effective at Reducing Acrylamide and Oil Content of French Fries

    Directory of Open Access Journals (Sweden)

    Asmaa Al-Asmar

    2018-04-01

    Full Text Available French fries are popular products worldwide. However, this product is a sufferable source of high acrylamide due to high temperature and low moisture. The main objective of this study was to evaluate the effect of grass pea flour (GPF, transglutaminase (TGase-treated (GPF + TGase, chitosan (CH, and pectin (PEC hydrocolloid coating solutions on the formation of acrylamide, water retention as well as on oil content. In addition, the Daily Intake (DI and Margin of Exposure (MOE were calculated to estimate variations in risk assessment by applying coating solutions before frying. Our results showed that the highest acrylamide content was detected in the control sample, reaching a value of 2089 µg kg−1. Hydrocolloid coating solutions were demonstrated to be an effective way to reduce acrylamide formation, with the percentage of acrylamide reduction equal to 48% for PEC, >38% for CH, ≥37% for GPF + TGase, and >31% for GPF, respectively. We hypothesized that the coatings were able to increase the water retention and, thus reduce the Maillard reaction, which is responsible for acrylamide formation. In fact, the MOE value for coated French fries was increase, resulting in being closer to the safety level to avoid carcinogenic risk. Moreover, our coatings were effective in reducing oil uptake.

  14. EFFICIENCY OF PROSTHETIC TREATMENT WITH POST RESECTION PROSTHESES WITH SOLID SUBSTITUTE PART

    Directory of Open Access Journals (Sweden)

    Ivan Gerdzhikov

    2016-08-01

    Full Text Available Aim: The aim of this study is to track the effectiveness of prosthetic treatment with post resection dentures with solid substitute part and their role in the restoration of damaged functions. Materials and methods: The study included 14 patients (9 men and 5 women with different size and location of defects in the upper jaw treated in the period 2010-2016 with post resection prostheses with a solid substitute part. The impressions were taken with irreversible hydrocolloid impression material. The prostheses were completed by heat-curing acrylic with low quantity residual monomer. The effectiveness of prosthetics was evaluated by the method of Mihaylov for both oral-nasal examination of the pressure with the device "Oronasopneumotest." For objectifying and assess the occlusal-articulation ratios was held computerized occlusal analysis with the system T-SCAN 8. Results: The results showed successful obturation and sealing of defects in all patients. It was found satisfactory recovery of the speaking function and normalization of occlusal-articulation ratios. Conclusion: The prosthetic treatment with post resection prostheses with a solid substitute part allows successful recovery of the lost speech and chewing functions, helping to restore self esteem and social rehabilitation of patients.

  15. [Impressions techniques--Part 2].

    Science.gov (United States)

    Levartovsky, S; Masri, M; Alter, E; Pilo, R

    2012-10-01

    A dental impression is a positive replica of the teeth, the surrounding gingiva and the border between them; the purpose of which is to create an accurate master model. Two major techniques for impressions exist today: The conventional and the digital impressions. The current article describes both techniques. In the conventional impressions, it is important to choose a proper tray, stock or custom, and to mix the material properly. The commonly used impression techniques for making a conventional impression are described with a review on the effect of the technique on its accuracy. The effect of the wash bulk on the accuracy of the stone dies and/or the restoration is discussed, as well. The digital impressions with their advantages and disadvantages are described in comparison to the conventional impressions. Although, digital impressions eliminate some of the negative characteristics of conventional impressions, proper soft-tissue management and isolation of tooth preparation margins is still mandatory.

  16. Evaluation of different methods of optical impression making on the marginal gap of onlays created with CEREC 3D.

    Science.gov (United States)

    da Costa, Juliana B; Pelogia, Fernanda; Hagedorn, Bradley; Ferracane, Jack L

    2010-01-01

    This study evaluated the marginal gaps on several surfaces of onlays created with the Cerec 3D system using one intraoral and two extraoral optical impression methods. A human molar (#19) was mounted with its adjacent teeth on a typodont (Frasaco) and prepared for a MODL onlay. The typodont was assembled in the mannequin head in order to simulate clinical conditions. The same operator took 36 individual optical impressions using a CEREC 3D camera. For group 1 (IP), a thin layer of titanium dioxide powder (CEREC powder-VITA) was applied directly onto the surface of the preparation for imaging (n = 12). For group 2 (EP), a sectional impression was taken with hydrocolloid Identic Syringable (Dux Dental), a die made with polyvinylsiloxane KwikkModel Scan (R-dental Dentalerzeugnisse GmbH) and powdered with titanium dioxide for imaging (n = 12). For group 3 (ES), a sectional impression was taken with PVS and a sectional stock tray, a die fabricated in stone (Diamond die- HI-TEC Dental Products) and the die being imaged without powdering (n = 12). One operator designed and machined the onlays in VitaBlocks Mark II for Cerec (VITA) using a CEREC 3D. The marginal gaps (microm) were measured with an optical microscope (50x) at 12 points, three on each surface of the MODL. The results were analyzed by two-way ANOVA/ Tukey's (p = 0.05). The overall mean marginal gaps (microm) for the three methods were: IP = 111.6 (+/- 34.0); EP = 161.4 (+/- 37.6) and ES = 116.8 (+/- 42.3). IP and ES were equal, but both were significantly less than EP. The pooled mean marginal gaps (microm) for the occlusal = 110.5 (+/- 39) and lingual = 111.5 (+/- 30.5) surfaces were equivalent and significantly less than the distal = 136.5 (+/- 42.5) and mesial = 161.1 (+/- 43.3). The marginal gap of CEREC 3D onlay restorations was not different when the optical impression was taken intraorally vs extraorally using a stone cast that does not require powdering. The lingual and occlusal surfaces showed the

  17. Accuracy of impressions with different impression materials in ...

    African Journals Online (AJOL)

    Purpose: To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two ... materials in a special tray, using a open tray impression technique from the master casts. These impressions were poured to obtain test casts.

  18. Influence of tribomechanical micronization and hydrocolloids addition on enthalpy and apparent specific heat of whey protein model solutions

    Directory of Open Access Journals (Sweden)

    Zoran Herceg

    2002-01-01

    Full Text Available Knowledge of thermophysical properties, especially the phase transitions temperature, specific heat and enthalpy, are essential in defining the freezing process parameters as well as storage conditions of frozen food. In this work thermophysical properties of 10% model solutions prepared with 60% whey protein concentrate (WPC with various hydrocolloids addition (HVEP, YO-EH, YO-L i YO-M were investigated. Powdered whey protein concentrate was treated in equipment for tribomechanical micronization and activation at 40000 rpm (Patent: PCT/1B99/00757 just before model solutions preparation. Particle size analysis was performed using Frich –laser particle sizer “analysette 22”. The phase transition temperatures were determined by differential thermal analysis (DTA, while specific heat and enthalpy were calculated according to several mathematical equations. The results have shown that, due to tribomechanical treatment, certain changes in thermophysical and energetic properties of materials occurred. Tribomechanical treatment affects changes in granulometrical composition of WPC which result in higher abilities of reactions with hydrocolloids in model solutions and significant changes in thermophysical properties of the mentioned models.

  19. Characterization of lycopene hydrocolloidal structure induced by tomato processing.

    Science.gov (United States)

    Jazaeri, Sahar; Mohammadi, Abdorreza; Kermani, Amir Mehrabi Panah; Paliyath, Gopinadhan; Kakuda, Yukio

    2018-04-15

    Tomato juice and paste are special type of dispersions, composed of suspended particles (pulp) dispersed in a colloidal liquid medium (serum). The bright red appearance of soluble solid separated by high speed centrifugation denoted the presence of lycopene in this fraction. Since lycopene is a hydrophobic compound it is not expected to appear in the water soluble fraction. HPLC analysis indicated presence of substantial amount of lycopene in soluble fraction which was confirmed by the appearance of lycopene crystals when observed under Transmission Electron Microscope (TEM). Considerable amount of pectin in the soluble fraction led to hypothesis that pectin facilitated the formation of hydrocolloidal system of suspended lycopene during processing. Enzyme treatment confirmed this hypothesis when pectinase effectively disrupted colloidal system and precipitated lycopene. Necessity of the divalent ions to retain the suspension signified the electrostatic interactions in the matrix surrounding lycopene crystals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. [Precision of digital impressions with TRIOS under simulated intraoral impression taking conditions].

    Science.gov (United States)

    Yang, Xin; Sun, Yi-fei; Tian, Lei; Si, Wen-jie; Feng, Hai-lan; Liu, Yi-hong

    2015-02-18

    To evaluate the precision of digital impressions taken under simulated clinical impression taking conditions with TRIOS and to compare with the precision of extraoral digitalizations. Six #14-#17 epoxy resin dentitions with extracted #16 tooth preparations embedded were made. For each artificial dentition, (1)a silicone rubber impression was taken with individual tray, poured with type IV plaster,and digitalized with 3Shape D700 model scanner for 10 times; (2) fastened to a dental simulator, 10 digital impressions for each were taken with 3Shape TRIOS intraoral scanner. To assess the precision, best-fit algorithm and 3D comparison were conducted between repeated scan models pairwise by Geomagic Qualify 12.0, exported as averaged errors (AE) and color-coded diagrams. Non-parametric analysis was performed to compare the precisions of digital impressions and model images. The color-coded diagrams were used to show the deviations distributions. The mean of AE for digital impressions was 7.058 281 μm, which was greater than that of 4.092 363 μm for the model images (Pimpressions were no more than 10 μm, which meant that the consistency between the digital impressions was good. The deviations distribution was uniform in the model images,while nonuniform in the digital impressions with greater deviations lay mainly around the shoulders and interproximal surfaces. Digital impressions with TRIOS are of good precision and up to the clinical standard. Shoulders and interproximal surfaces scanning are more difficult.

  1. Influence of hydrocolloidal silver nanoparticles on gastrointestinal microflora and morphology of enterocytes of quails

    DEFF Research Database (Denmark)

    Sawosz, Ewa; Binek, Marian; Grodzik, Marta

    2007-01-01

    The objective of the present study was to examine the effects of hydrocolloidal silver nanoparticles (Ag-nano) on microbial profile of caecum and morphology of enterocytes in duodenum of Japanese quail, as a model animal for poultry. Quails (Coturnix coturnix japonica) (10 d old) were randomly...... killed and samples of duodenum and caeca microflora were collected. This initial investigation demonstrated that silver nanoparticles did not influence emphatically microflora of quail caecum; however, water containing 25 mg/kg of Ag-nano significantly increased the population of lactic acid bacteria...

  2. Irreversible processes kinetic theory

    CERN Document Server

    Brush, Stephen G

    2013-01-01

    Kinetic Theory, Volume 2: Irreversible Processes deals with the kinetic theory of gases and the irreversible processes they undergo. It includes the two papers by James Clerk Maxwell and Ludwig Boltzmann in which the basic equations for transport processes in gases are formulated, together with the first derivation of Boltzmann's ""H-theorem"" and a discussion of this theorem, along with the problem of irreversibility.Comprised of 10 chapters, this volume begins with an introduction to the fundamental nature of heat and of gases, along with Boltzmann's work on the kinetic theory of gases and s

  3. In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Sonam Gupta

    2017-01-01

    Full Text Available Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique. Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level impressions were made. Eight groups (n=5 were tested using impression materials (polyether and vinylsiloxanether and four types of impression trays, two being custom (self-cure acrylic and light cure acrylic and two being stock (plastic and metal. The interimplant distances were measured on master casts using a coordinate measuring machine. The collected data was compared with a standard reference model and was statistically analyzed using two-way ANOVA. Results. Statistically significant difference (p0.05 was observed between varied stock and custom trays. Conclusions. The polyether impression material proved to be more accurate than vinylsiloxanether impression material. The rigid nonperforated stock trays, both plastic and metal, could be an alternative for custom trays for multi-implant impressions when used with medium viscosity impression materials.

  4. Two-step impression/ injection, an alternative putty/ wash impression technique: case report.

    Science.gov (United States)

    Caputi, S; Murmura, G; Sinjari, B; Varvara, G

    2012-01-01

    We here describe a new technique for making a definitive impression that we refer to as the two-step impression/injection technique. This technique initially follows the classical one-step putty/ light-body impression technique with the polymerization of the putty and the light-body compound. This is then followed by the second step: injection of extra-light-body compound into the preparation through a hole in the metal stock tray. The aim of this additional step is to control the wash bulk and minimize the changes that can produce unfavorable impression results. This new two-step impression/injection technique allows displacement of soft tissues, such as the tongue, during the first seating of the putty and wash materials, while in the second step, the extra-light-body compound records all of the finer details without being compressed.

  5. A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material.

    Science.gov (United States)

    Manoj, Smita Sara; Cherian, K P; Chitre, Vidya; Aras, Meena

    2013-12-01

    There is much discussion in the dental literature regarding the superiority of one impression technique over the other using addition silicone impression material. However, there is inadequate information available on the accuracy of different impression techniques using polyether. The purpose of this study was to assess the linear dimensional accuracy of four impression techniques using polyether on a laboratory model that simulates clinical practice. The impression material used was Impregum Soft™, 3 M ESPE and the four impression techniques used were (1) Monophase impression technique using medium body impression material. (2) One step double mix impression technique using heavy body and light body impression materials simultaneously. (3) Two step double mix impression technique using a cellophane spacer (heavy body material used as a preliminary impression to create a wash space with a cellophane spacer, followed by the use of light body material). (4) Matrix impression using a matrix of polyether occlusal registration material. The matrix is loaded with heavy body material followed by a pick-up impression in medium body material. For each technique, thirty impressions were made of a stainless steel master model that contained three complete crown abutment preparations, which were used as the positive control. Accuracy was assessed by measuring eight dimensions (mesiodistal, faciolingual and inter-abutment) on stone dies poured from impressions of the master model. A two-tailed t test was carried out to test the significance in difference of the distances between the master model and the stone models. One way analysis of variance (ANOVA) was used for multiple group comparison followed by the Bonferroni's test for pair wise comparison. The accuracy was tested at α = 0.05. In general, polyether impression material produced stone dies that were smaller except for the dies produced from the one step double mix impression technique. The ANOVA revealed a highly

  6. Impression Generation of Indonesian Cultural Paintings for Mobile Application with Culture Dependent Color-Impression Metric Creation Contents

    Directory of Open Access Journals (Sweden)

    Devira Nanda Kuswhara

    2014-06-01

    Full Text Available Painting is one of complex image reflecting observations and feelings of the artist to the environment. This condition extends the need of painting impression generation system since common people with lack of art experience would have difficulties to interpret the painting. From this point of view we presents a new model to provide representative impressions of paintings by providing a color-impression metric taken from public survey and implement it for mobile application. The new model provides analytical functions to generate the representative impression of the image query. The functions consist of two main section: (1 The cultural-dependent color-impression metric creation which consist of conducting survey, applying normalized 3D color vector quantization to image dataset, generating image-impression metric, and generating color- impression metric; and (2 Impression generation of image query which consist of applying normalized 3D color vector quantization to image query and measuring the similarity between image query andcolor-impression metric. To perform our proposed impression generation system, we examine our system with Indonesian cultural image dataset and 5 different mobile devices. Our proposed system performs main color impression precision result with average precision of more than 60%. Brightness intensity and zooming affects the retrieved impressions. Rotating captures of an image generate the same retrieved impressions. The system also performs average response time vary in range 41263 to 117434 milliseconds from all devices. Keywords: impression generation system, color based impression, cultural computing, mobile application.

  7. Impression block with orientator

    International Nuclear Information System (INIS)

    Brilin, V I; Ulyanova, O S

    2015-01-01

    Tool review, namely the impression block, applied to check the shape and size of the top of fish as well as to determine the appropriate tool for fishing operation was realized. For multiple application and obtaining of the impress depth of 3 cm and more, the standard volumetric impression blocks with fix rods are used. However, the registered impress of fish is not oriented in space and the rods during fishing are in the extended position. This leads to rods deformation and sinking due to accidental impacts of impression block over the borehole irregularity and finally results in faulty detection of the top end of fishing object in hole. The impression blocks with copy rods and fixed magnetic needle allow estimating the object configuration and fix the position of magnetic needle determining the position of the top end of object in hole. However, the magnetic needle fixation is realized in staged and the rods are in extended position during fishing operations as well as it is in standard design. The most efficient tool is the impression block with copy rods which directs the examined object in the borehole during readings of magnetic needles data from azimuth plate and averaging of readings. This significantly increases the accuracy of fishing toll direction. The rods during fishing are located in the body and extended only when they reach the top of fishing object

  8. Irreversibility and self-organization in spin glasses. 1. Origin of irreversibility in spin glasses

    International Nuclear Information System (INIS)

    Kovrov, V.P.; Kurbatov, A.M.

    1989-05-01

    The origin of irreversibility in spin glasses is found out on the basis of the analytical study of the well-known TAP equations. Connection between irreversible jumpwise transitions and a positive feedback in spin glasses is discussed. (author). 7 refs, 4 figs

  9. A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material

    OpenAIRE

    Manoj, Smita Sara; Cherian, K. P.; Chitre, Vidya; Aras, Meena

    2013-01-01

    There is much discussion in the dental literature regarding the superiority of one impression technique over the other using addition silicone impression material. However, there is inadequate information available on the accuracy of different impression techniques using polyether. The purpose of this study was to assess the linear dimensional accuracy of four impression techniques using polyether on a laboratory model that simulates clinical practice. The impression material used was Impregu...

  10. ETI: Our first impressions

    Science.gov (United States)

    Harrison, Albert A.; Johnson, Joel T.

    2000-06-01

    Despite scant or ambiguous information, people are capable of developing comprehensive and detailed impressions. Consequently, if the detection of an electromagnetically-active civilization is announced, many people will rapidly form impressions of what the extraterrestrials and their civilization are "like". First impressions are crucial, not only because of their immediate psychological, social, and political consequences on Earth, but because they can influence the future of interstellar communication. Initial impressions will rest less on hard data than on the nature and tone of the "evidence" that is gleaned from the transmission; the interpretation and dissemination of this evidence; and the hard wiring, psychological programming, cultural conditioning, and social influence processes that shape human perception. We consider how dispositional inferences, implicit theories of personality, negatively toned or adverse information, physical appearance, prior expectations, the confirmation bias, and thinking and unthinking approaches to attitude formation are likely to affect human impressions of ETI.

  11. Comparison of Adaptation between the Major Connectors Fabricated from Intraoral Digital Impressions and Extraoral Digital Impressions.

    Science.gov (United States)

    Gan, Ning; Ruan, Yaye; Sun, Jian; Xiong, Yaoyang; Jiao, Ting

    2018-01-11

    The objective was to compare the adaptation between the major connectors of removable partial dentures derived from intraoral digital impressions and extraoral digital impressions. Twenty-four volunteers were enrolled. Each volunteer received an intraoral digital impression and one extraoral digital impression digitized from conventional gypsum impression. A software was used to create the major connectors on digital impression datasets. After all the virtual major connectors designed from Group intraoral digital impressions (Group I) and Group extraoral digital impressions (Group E) were directly fabricated by 3D printing technique, the adaptation of the final major connectors in volunteers' mouths were measured. The adaptation ranged from 159.87 to 577.99 μm in Group I while from 120.83 to 536.17 μm in Group E. The adaptation of major connectors in Group I were found better at the midline palatine suture while the adaptation of major connectors in Group E were found better at the two sides of the palatal vault. In both groups, the highest accuracy in adaptation was revealed at the anterior margin of the major connectors. It is feasible to manufacture the major connectors by digital impression and 3D printing technique. Both the adaptation of the two kinds of digital impressions were clinical acceptable.

  12. Giving the wrong impression: food and beverage brand impressions delivered to youth through popular movies.

    Science.gov (United States)

    Skatrud-Mickelson, Monica; Adachi-Mejia, Anna M; MacKenzie, Todd A; Sutherland, Lisa A

    2012-06-01

    Marketing on television showcases less-healthful options, with emerging research suggesting movies promote similar products. Given the obesity epidemic, understanding advertising to youth should be a public health imperative. The objective of this study was to estimate youth impressions to food and beverages delivered through movies. Impressions were calculated by dividing US receipts annually into average movie ticket prices, then multiplying this by the number of brand appearances. Examination by ratings, product types and ages were conducted by Spearman rank correlation coefficient tests. Youth in the USA saw over 3 billion food, beverage or food-retail establishment (FRE) impressions on average, annually from 1996 to 2005. Those aged 12-18 viewed over half of all impressions, with PG-13-rated movies containing 61.5% of impressions. There were no significant trends in brand appearances by food, beverage or FRE impressions over the decade, although there was a decreasing trend in R-rated impressions for both foods (Pbeverages (Pfood and beverage impressions annually to youth. Given the public health crisis of obesity, future research should further investigate these trends, as well as the potential association of these unhealthy exposures in youth.

  13. Effects of addition of hydrocolloids on the textural and structural properties of high-protein intermediate moisture food model systems containing sodium caseinate.

    Science.gov (United States)

    Li, J; Wu, Y; Ma, Y; Lu, N; Regenstein, J M; Zhou, P

    2017-08-01

    High-protein intermediate moisture food (HPIMF) containing sodium caseinate (NaCN) often gave a harder texture compared with that made from whey proteins or soy proteins, due to the aggregation of protein particles. The objectives of this study were to explore whether the addition of hydrocolloids could soften the texture and illustrate the possible mechanism. Three kinds of hydrocolloids, xanthan gum, κ-carrageenan, and gum arabic were chosen, and samples including of these three kinds of hydrocolloids were studied through texture analysis using a TPA test and microstructure observation by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). The texture analysis results showed that xanthan gum was more effective at softening the HPIMF containing NaCN compared to κ-carrageenan and gum arabic. In addition, with the increase of xanthan gum concentration from 0.2 to 2%, the HPIMF matrix became softer, and fractures were observed during the compression for samples with xanthan gum added at low concentrations but not 2%. Microstructure observation suggested that the matrix originally dominated by the network formed through the aggregation of swollen protein particles was inhibited by the addition of xanthan gum, resulting in the softening of the texture and also contributing to the fracture during compression. With the increase of xanthan gum concentration up to 2%, the protein dominating network would be gradually replaced with a matrix dominated by the newly formed network of xanthan gum with protein particles as fillers. Furthermore, this formation of a xanthan gum dominating network structure also resulted in changes in small molecule distribution, as observed using low-field NMR.

  14. Linear dimensional changes in plaster die models using different elastomeric materials

    Directory of Open Access Journals (Sweden)

    Jefferson Ricardo Pereira

    2010-09-01

    Full Text Available Dental impression is an important step in the preparation of prostheses since it provides the reproduction of anatomic and surface details of teeth and adjacent structures. The objective of this study was to evaluate the linear dimensional alterations in gypsum dies obtained with different elastomeric materials, using a resin coping impression technique with individual shells. A master cast made of stainless steel with fixed prosthesis characteristics with two prepared abutment teeth was used to obtain the impressions. References points (A, B, C, D, E and F were recorded on the occlusal and buccal surfaces of abutments to register the distances. The impressions were obtained using the following materials: polyether, mercaptan-polysulfide, addition silicone, and condensation silicone. The transfer impressions were made with custom trays and an irreversible hydrocolloid material and were poured with type IV gypsum. The distances between identified points in gypsum dies were measured using an optical microscope and the results were statistically analyzed by ANOVA (p < 0.05 and Tukey's test. The mean of the distances were registered as follows: addition silicone (AB = 13.6 µm, CD=15.0 µm, EF = 14.6 µm, GH=15.2 µm, mercaptan-polysulfide (AB = 36.0 µm, CD = 36.0 µm, EF = 39.6 µm, GH = 40.6 µm, polyether (AB = 35.2 µm, CD = 35.6 µm, EF = 39.4 µm, GH = 41.4 µm and condensation silicone (AB = 69.2 µm, CD = 71.0 µm, EF = 80.6 µm, GH = 81.2 µm. All of the measurements found in gypsum dies were compared to those of a master cast. The results demonstrated that the addition silicone provides the best stability of the compounds tested, followed by polyether, polysulfide and condensation silicone. No statistical differences were obtained between polyether and mercaptan-polysulfide materials.

  15. Digital vs. conventional implant impressions: efficiency outcomes.

    Science.gov (United States)

    Lee, Sang J; Gallucci, German O

    2013-01-01

    The aim of this pilot study was to evaluate the efficiency, difficulty and operator's preference of a digital impression compared with a conventional impression for single implant restorations. Thirty HSDM second year dental students performed conventional and digital implant impressions on a customized model presenting a single implant. The outcome of the impressions was evaluated under an acceptance criteria and the need for retake/rescan was decided. The efficiency of both impression techniques was evaluated by measuring the preparation, working, and retake/scan time (m/s) and the number of retakes/rescans. Participants' perception on the level of difficulty for the both impressions was assessed with a visual analogue scale (VAS) questionnaire. Multiple questionnaires were obtained to assess the participants' perception on preference, effectiveness and proficiency. Mean total treatment time was of 24:42 m/s for conventional and 12:29 m/s for digital impressions (P impressions (P impression (P impression technique and 30.63 (±17.57) for digital impression technique (P = 0.006). Sixty percent of the participants preferred the digital impression, 7% the conventional impression technique and 33% preferred either technique. Digital impressions resulted in a more efficient technique than conventional impressions. Longer preparation, working, and retake time were consumed to complete an acceptable conventional impression. Difficulty was lower for the digital impression compared with the conventional ones when performed by inexperienced second year dental students. © 2012 John Wiley & Sons A/S.

  16. Accuracy of a new elastomeric impression material for complete-arch dental implant impressions.

    Science.gov (United States)

    Baig, Mirza R; Buzayan, Muaiyed M; Yunus, Norsiah

    2018-05-01

    The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts. Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05. The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05). The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions. © 2018 John Wiley & Sons Australia, Ltd.

  17. Examination of various postulates of irreversibility

    Energy Technology Data Exchange (ETDEWEB)

    Salmon, J [Conservatoire National des Arts et Metiers (CNAM), 75 - Paris (France)

    1977-01-01

    Firstly, it is shown that it is necessary to break the reversible character of the B.B.G.K.Y. system of equations by means of a postulate of irreversibility to obtain a kinetic equation compatible with the second principle of thermodynamics. Next, three postulates of irreversibility are examined: that of molecular chaos, that of linear relaxation and, finally, that of superposition. Then the corresponding kinetic equations and the expressions for the viscosity coefficient to which they lead are determined. Comparison with experiment is made each time. Lastly, an attempt to obtain an irreversible kinetic equation without introducing a postulate of irreversibility in the B.B.G.K.Y. system is realized. This consists in adding a complementary irreversible term to the fundamental equation of the dynamics of a particle. The suggested term is of quantum origin and leads to a kinetic equation of the Fokker-Planck type.

  18. Giving the wrong impression: food and beverage brand impressions delivered to youth through popular movies

    Science.gov (United States)

    Skatrud-Mickelson, Monica; Adachi-Mejia, Anna M.; MacKenzie, Todd A.; Sutherland, Lisa A.

    2012-01-01

    Background Marketing on television showcases less-healthful options, with emerging research suggesting movies promote similar products. Given the obesity epidemic, understanding advertising to youth should be a public health imperative. The objective of this study was to estimate youth impressions to food and beverages delivered through movies. Methods Impressions were calculated by dividing US receipts annually into average movie ticket prices, then multiplying this by the number of brand appearances. Examination by ratings, product types and ages were conducted by Spearman rank correlation coefficient tests. Results Youth in the USA saw over 3 billion food, beverage or food–retail establishment (FRE) impressions on average, annually from 1996 to 2005. Those aged 12–18 viewed over half of all impressions, with PG-13-rated movies containing 61.5% of impressions. There were no significant trends in brand appearances by food, beverage or FRE impressions over the decade, although there was a decreasing trend in R-rated impressions for both foods (P< 0.01) and beverages (P< 0.01), but not FREs (P= 0.08). Conclusions Movies promote billions of food and beverage impressions annually to youth. Given the public health crisis of obesity, future research should further investigate these trends, as well as the potential association of these unhealthy exposures in youth. PMID:22076600

  19. METHODOLOGY OF PROSTHETIC TREATMENT IN PATIENTS WITH MAXILLECTOMY

    Directory of Open Access Journals (Sweden)

    Ivan Gerdzhikov

    2018-06-01

    Full Text Available Aim: The aim of the described method is to present the main stages in the prosthetic treatment with hollow bulb obturator, which provides optimum defect hermetization and restoration of the damaged functions. Materials and methods: The clinical case, described is on a 70-years-old patient with edentulous jaws and maxillary defect in the right half of the upper jaw. The preliminary impressions were taken with irreversible hydrocolloid impression material, and the final impressions were taken with additive silicone material. The occlusion height and the centric relations were registered as the classical technique. After the successful trial denture appointment, the surface of the plaster master model was covered by isolation polish. After this procedure, the master model was covered by even wax layer with 5mm thickness. It was designed to be thinner in the area of the resection line. The designed cavity was filled in with silicone impression material and covered with the folio. The base plate with the arranged teeth was fixed to the model, packed in the cuvette and finished from heat-cured acrylic resin with low quantity of residual monomer. After the polymerization process, the silicone material was removed, and the obturators cap was fixed to the denture’s base plate with cold cured acrylic resin. The obturator and the complete denture of the mandible were adjusted and articulated in patient’s mouth in the final clinical stage. Results: The applied prosthetic method allowed successful defect hermetization and helped for the restoration of the speech, feeding and patient’s self-esteem. Conclusion: Prosthetic rehabilitation of patients with maxillary resection is possible only with the application of specific treatment methods.

  20. Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions

    Science.gov (United States)

    Yang, Xin; Lv, Pin; Liu, Yihong; Si, Wenjie; Feng, Hailan

    2015-01-01

    In this study, the accuracy (precision and trueness) of digital impressions and the fitness of single crowns manufactured based on digital impressions were evaluated. #14-17 epoxy resin dentitions were made, while full-crown preparations of extracted natural teeth were embedded at #16. (1) To assess precision, deviations among repeated scan models made by intraoral scanner TRIOS and MHT and model scanner D700 and inEos were calculated through best-fit algorithm and three-dimensional (3D) comparison. Root mean square (RMS) and color-coded difference images were offered. (2) To assess trueness, micro computed tomography (micro-CT) was used to get the reference model (REF). Deviations between REF and repeated scan models (from (1)) were calculated. (3) To assess fitness, single crowns were manufactured based on TRIOS, MHT, D700 and inEos scan models. The adhesive gaps were evaluated under stereomicroscope after cross-sectioned. Digital impressions showed lower precision and better trueness. Except for MHT, the means of RMS for precision were lower than 10 μm. Digital impressions showed better internal fitness. Fitness of single crowns based on digital impressions was up to clinical standard. Digital impressions could be an alternative method for single crowns manufacturing. PMID:28793417

  1. Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions

    Directory of Open Access Journals (Sweden)

    Xin Yang

    2015-06-01

    Full Text Available In this study, the accuracy (precision and trueness of digital impressions and the fitness of single crowns manufactured based on digital impressions were evaluated. #14-17 epoxy resin dentitions were made, while full-crown preparations of extracted natural teeth were embedded at #16. (1 To assess precision, deviations among repeated scan models made by intraoral scanner TRIOS and MHT and model scanner D700 and inEos were calculated through best-fit algorithm and three-dimensional (3D comparison. Root mean square (RMS and color-coded difference images were offered. (2 To assess trueness, micro computed tomography (micro-CT was used to get the reference model (REF. Deviations between REF and repeated scan models (from (1 were calculated. (3 To assess fitness, single crowns were manufactured based on TRIOS, MHT, D700 and inEos scan models. The adhesive gaps were evaluated under stereomicroscope after cross-sectioned. Digital impressions showed lower precision and better trueness. Except for MHT, the means of RMS for precision were lower than 10 μm. Digital impressions showed better internal fitness. Fitness of single crowns based on digital impressions was up to clinical standard. Digital impressions could be an alternative method for single crowns manufacturing.

  2. Substance Use as Impression Management.

    Science.gov (United States)

    Sharp, Mark J.; Getz, J. Greg

    1996-01-01

    Examines the function of substance use as an impression management tactic. Introductory psychology students (n=377) responded to a survey instrument measuring self-monitoring, perceived success in impression management, interaction anxiety, and self-esteem. Results suggest that alcohol use may serve an impression management function. (JPS)

  3. Ecological optimization for generalized irreversible Carnot refrigerators

    International Nuclear Information System (INIS)

    Chen Lingen; Zhu Xiaoqin; Sun Fengrui; Wu Chih

    2005-01-01

    The optimal ecological performance of a Newton's law generalized irreversible Carnot refrigerator with the losses of heat resistance, heat leakage and internal irreversibility is derived by taking an ecological optimization criterion as the objective, which consists of maximizing a function representing the best compromise between the exergy output rate and exergy loss rate (entropy production rate) of the refrigerator. Numerical examples are given to show the effects of heat leakage and internal irreversibility on the optimal performance of generalized irreversible refrigerators

  4. Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study

    Science.gov (United States)

    Pilla, Ajai; Pathipaka, Suman

    2016-01-01

    Introduction The dimensional stability of the impression material could have an influence on the accuracy of the final restoration. Vinyl Polysiloxane Impression materials (VPS) are most frequently used as the impression material in fixed prosthodontics. As VPS is hydrophobic when it is poured with gypsum products, manufacturers added intrinsic surfactants and marketed as hydrophilic VPS. These hydrophilic VPS have shown increased wettability with gypsum slurries. VPS are available in different viscosities ranging from very low to very high for usage under different impression techniques. Aim To compare the dimensional accuracy of hydrophilic VPS and hydrophobic VPS using monophase, one step and two step putty wash impression techniques. Materials and Methods To test the dimensional accuracy of the impression materials a stainless steel die was fabricated as prescribed by ADA specification no. 19 for elastomeric impression materials. A total of 60 impressions were made. The materials were divided into two groups, Group1 hydrophilic VPS (Aquasil) and Group 2 hydrophobic VPS (Variotime). These were further divided into three subgroups A, B, C for monophase, one-step and two-step putty wash technique with 10 samples in each subgroup. The dimensional accuracy of the impressions was evaluated after 24 hours using vertical profile projector with lens magnification range of 20X-125X illumination. The study was analyzed through one-way ANOVA, post-hoc Tukey HSD test and unpaired t-test for mean comparison between groups. Results Results showed that the three different impression techniques (monophase, 1-step, 2-step putty wash techniques) did cause significant change in dimensional accuracy between hydrophilic VPS and hydrophobic VPS impression materials. One-way ANOVA disclosed, mean dimensional change and SD for hydrophilic VPS varied between 0.56% and 0.16%, which were low, suggesting hydrophilic VPS was satisfactory with all three impression techniques. However, mean

  5. Effect of the addition of hydrocolloids on the rheological and baking properties of the products with added spelt flour (Triticum spelta L.

    Directory of Open Access Journals (Sweden)

    Tatiana Bojňanská

    2016-01-01

    Full Text Available The paper presents the results of the evaluation of the effect of additives on the rheological properties of composite flour made of wheat flour in the amount of 70% and spelt flour at 30%. As additives guar gum (0.5% by weight of flour and xanthan gum (0.16% by weight of flour were used. Properties of produced control dough and doughs with hydrocolloids were evaluated by means of rheological appliances by Farinograph, Extenzograph, Amylograph and Rheofermentometer. Based on the observed results it can be concluded that the addition of xanthan gum has a positive effect on increasing of farinographic water absorption capacity, extension of dough development time and dough stability and generally positively affected farinographic properties. The addition of guar gum has improved especially extensographic properties as extensographic energy and extensographic resistance. Based on amylographic evaluation of control doughs and doughs with additives it can be stated that in the dough with guar gum the amylographic maximum has slightly increased. Hydrocolloid guar gum contributed to an increased retention capacity of dough observed. Based on our measurements we can indicate that addition of guar and xanthan gum contributed to an increased rheological quality of doughs prepared with addition of flour from spelt wheat. With reference to the baking experiment it was found that the use of hydrocolloids has a positive effect on the improvement of the baking properties, in particular larger volume, specific volume, and the volume yield of the dough with the addition of guar and xanthan gum compared to the control. Our results showed that aditives significantly influenced rheological qualities of dough and a baking quality of products. These findings thus allow optimizing the recipe in order to increase the technological quality of leavened bakery products.

  6. Effects of implant system, impression technique, and impression material on accuracy of the working cast.

    Science.gov (United States)

    Wegner, Kerstin; Weskott, Katharina; Zenginel, Martha; Rehmann, Peter; Wöstmann, Bernd

    2013-01-01

    This in vitro study aimed to identify the effects of the implant system, impression technique, and impression material on the transfer accuracy of implant impressions. The null hypothesis tested was that, in vitro and within the parameters of the experiment, the spatial relationship of a working cast to the placement of implants is not related to (1) the implant system, (2) the impression technique, or (3) the impression material. A steel maxilla was used as a reference model. Six implants of two different implant systems (Standard Plus, Straumann; Semados, Bego) were fixed in the reference model. The target variables were: three-dimensional (3D) shift in all directions, implant axis direction, and rotation. The target variables were assessed using a 3D coordinate measuring machine, and the respective deviations of the plaster models from the nominal values of the reference model were calculated. Two different impression techniques (reposition/pickup) and four impression materials (Aquasil Ultra, Flexitime, Impregum Penta, P2 Magnum 360) were investigated. In all, 80 implant impressions for each implant system were taken. Statistical analysis was performed using multivariate analysis of variance. The implant system significantly influenced the transfer accuracy for most spatial dimensions, including the overall 3D shift and implant axis direction. There was no significant difference between the two implant systems with regard to rotation. Multivariate analysis of variance showed a significant effect on transfer accuracy only for the implant system. Within the limits of the present study, it can be concluded that the transfer accuracy of the intraoral implant position on the working cast is far more dependent on the implant system than on the selection of a specific impression technique or material.

  7. The quality of fixed prosthodontic impressions: An assessment of crown and bridge impressions received at commercial laboratories.

    Science.gov (United States)

    Rau, Clayton T; Olafsson, Vilhelm G; Delgado, Alex J; Ritter, André V; Donovan, Terry E

    2017-09-01

    The authors evaluated and quantified clinically detectable errors commonly seen in impressions sent to commercial laboratories and determined possible relationships between finish line errors and other factors involved. The authors visited 3 large and 1 small commercial dental laboratories over a 12-month period. Three calibrated examiners evaluated the impressions. The examiners evaluated all impressions for errors by using ×2.5 magnification loupes under ambient room lighting without the aid of additional illumination. The authors evaluated 1,157 impressions; 86% of the examined impressions had at least 1 detectable error, and 55% of the noted errors were critical errors pertaining to the finish line. The largest single error categories evaluated were tissue over the finish line (49.09%), lack of unprepared stops in dual-arch impressions (25.63%), pressure of the tray on the soft tissue (25.06%), and void at the finish line (24.38%). The factors blood on the impression (odds ratio, 2.31; P impressions evaluated. The authors noted an increase in errors at the finish line with dual-arch impression techniques and in the presence of blood. Dentists have ethical, moral, and legal obligations bestowed on them by the profession and need to evaluate critically the work they send to laboratories. The authors strongly recommend an improvement in technique and reviewing of all impressions and working casts. Published by Elsevier Inc.

  8. Patients' preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions (Intraoral Scan) of dental implants.

    Science.gov (United States)

    Wismeijer, Daniel; Mans, Ronny; van Genuchten, Michiel; Reijers, Hajo A

    2014-10-01

    The primary objective of this clinical study was to assess the patients' perception of the difference between an analogue impression approach on the one hand and an intra-oral scan (IO scan) on the other when restoring implants in the non-aesthetic zone. A second objective was to analyse the difference in time needed to perform these two procedures. Thirty consecutive patients who had received 41 implants (Straumann tissue level) in the non-aesthetic zone in an implant-based referral practice setting in the Netherlands. As they were to receive crown and or bridge work on the implants, in one session, the final impressions were taken with both an analogue technique and with an intraoral scan. Patients were also asked if, directly after the treatment was carried out, they would be prepared to fill out a questionnaire on their perception of both techniques. The time involved following these two procedures was also recorded. The preparatory activities of the treatment, the taste of the impression material and the overall preference of the patients were significantly in favour of the IO scan. The bite registration, the scan head and gag reflex positively tended to the IO scan, but none of these effects were significant. The overall time involved with the IO scan was more negatively perceived than the analogue impression. Overall less time was involved when following the analogue impression technique than with the IO scan. The overall preference of the patients in our sample is significantly in favour of the approach using the IO scan. This preference relates mainly to the differences between the compared approaches with respect to taste effects and their preparatory activities. The patients did perceive the duration of IO scan more negatively than the analogue impression approach. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Ventral impressions on the hypopharynx

    International Nuclear Information System (INIS)

    Daschner, H.; Hannig, C.

    1991-01-01

    Two impressions can be seen on the ventral aspect of the hypopharynx and upper oesophagus; on static images it is difficult to differentiate these from small tumours. In order to evaluate this region more accurately, we have examined 150 patients by means of rapid rate cinematography. In 52.6% we found a constant irregular or convex impression formed by the cricoid; in the other cases this was not seen or was quite minimal. In 93% a sub-cricoid impression could be demonstrated which was due to lax mucosa. Characteristically this showed a variable appearance during the passage of a bolus. Only the cricoid impression was associated with dysphagia. (orig.) [de

  10. The Historical Evolution of Dental Impression Materials.

    Science.gov (United States)

    Papadiochos, Ioannis; Papadiochou, Sofia; Emmanouil, Ioannis

    The concept of impression making process in dentistry began in the mid 1800s. Dentists realized that the construction of a prosthetic restoration required both a detailed capture of the oral tissues along with stone cast fabrications. To accomplish these goals, impression materials were essential. Beeswax represents the first impression material, while important bechmarks during the historical evolution of dental impression materials are considered to be the introduction of dental trays in the early 1800s and the invention of the gutta-percha, thermoplastic resins and plaster of Paris. The double (corrective) impression technique, along with the functional impression concept that was established after mid 1800s, are also identified as pivotal innovations. During the 20th century, the advances in material development slowed significantly since the majority of the current impression materials had already been invented. However, the introduction of elastomeric impression materials in the field of prosthodontics that offered the advantages of accuracy and dimensional stability substantially upgraded both the impression accuracy and the quality of the final restoration. Presently, the dental practitioner has access to a variety of impression materials and should be aware of their properties, indications and limitations as well. Futhermore, while continuous attempts are being made to enhance these materials, the ideal impression material has yet to be developed. The purpose of this article was to provide a comprehensive review about the historical development of impression dental materials. Copyright American Academy of the History of Dentistry.

  11. Accounting Narratives and Impression Management

    OpenAIRE

    Brennan, Niamh; Merkl-Davies, Doris M.

    2013-01-01

    This chapter focuses on impression management in accounting communication. Impression management entails the construction of an impression by organisations with the intention to appeal to their audiences, including shareholders, stakeholders, the general public, and the media. If successful, it undermines the quality of financial reporting and capital misallocations may result. What is more, wider social and political consequences include unwarranted support by non-financial...

  12. Entropy, Extropy and the Physical Driver of Irreversibility

    Directory of Open Access Journals (Sweden)

    Attila Grandpierre

    2012-06-01

    Full Text Available We point out that the fundamental irreversibility of Nature requires the introduction of a suitable measure for the distance from equilibrium. We show that entropy, which is widely held to be such a measure, suffers from the problem that it does not have a physical meaning, since it is introduced on the basis of mathematical arguments. As a consequence, the basic physics beyond irreversibility has remained obscure. We present here a simple but transparent physical approach for solving the problem of irreversibility. This approach shows that extropy, the fundamental thermodynamic variable introduced by Katalin Martinás, is the suitable measure for the distance from equilibrium, since it corresponds to the actual driver of irreversible processes. Since extropy explicitly contains in its definition all the general thermodynamic forces that drive irreversible processes, extropy is the suitable physical measure of irreversibility.

  13. Characterization of Gluten-free Bread Prepared From Maize, Rice and Tapioca Flours using the Hydrocolloid Seaweed Agar-Agar

    OpenAIRE

    Alvarenga, Nuno Bartolomeu; Cebola Lidon, Fernando; Belga, Elisa; Motrena, Patrícia; Guerreiro, Suse; Carvalho, Maria João; Canada, João

    2011-01-01

    Disponível em livre acesso no sítio do DOAJ em http://recent-science.com/index This work aims to check the rheological, physicochemical and sensory characteristics of gluten-free bread produced with corn, rice and tapioca flours, using the hydrocolloid seaweed agar-agar. Relatively to wheat bread, it was found that the pH was slightly lower in gluten-free bread. In the crust only the brightness remained significantly different between both bread types, but in the kernel, the parameters a*,...

  14. 21 CFR 872.6880 - Preformed impression tray.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6880 Preformed impression tray. (a) Identification. A preformed impression tray is a metal or plastic device intended to hold impression material... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Preformed impression tray. 872.6880 Section 872...

  15. How good are our impressions? An audit of alginate impression quality in the production of removable prostheses.

    Science.gov (United States)

    Horwitz, Richard

    2014-05-01

    Impressions are taken regularly in practice giving vital information to the dental laboratory, but are there quality assurance systems in place to make sure that they are up to a sufficient standard? As dental professionals we have to appreciate that dental technicians can only work with the information given to them. This makes the skill of taking a good impression vital in order for us as clinicians to provide prostheses of good quality. This paper outlines an audit of alginate impressions and their quality in the making of removable prostheses. To record the quality of impression taking, and how one's own ability to critique an impression may differ from that of our colleagues.

  16. Sulcus depth reproduction with polyvinyl siloxane impression material: effects of hydrophilicity and impression temperature.

    Science.gov (United States)

    Takahashi, Hidekazu; Finger, Werner J; Kurokawa, Rie; Furukawa, Masae; Komatsu, Masashi

    2010-03-01

    To determine the sulcus penetration ability of hydrophilic and hydrophobic polyvinyl siloxane (PVS) impression materials by impression technique, temperature, and sulcus width. Hydrophilic Flexitime (FLE; Heraeus Kulzer) and its hydrophobic counterpart (EXP) without surfactant were investigated, using light (L), monophase (M), and heavy (H) consistencies. A truncated steel cone surrounded by a 2-mm-deep and 50-, 100-, or 200-microm-wide sulcus, simulating the gingival tissue with agar, served as the test model. Impressions were made with single-mix (L or M) and double-mix (LM or LH) techniques at 23 degrees C and 37 degrees C, respectively. The reproduced sulcus heights were measured with a 3D laser scanner. Data were analyzed by ANOVA and Tukey HSD (P 1.9 mm); FLE-M, -LM, and-LH reproductions were shorter with narrow sulci. Reproductions of 50- and 100-microm sulci with EXP-L were shallower than with FLE-L. The shortest reproduction was, however, greater than 1.6 mm. In spite of some significant differences found in sulcus-reproducing ability with hydrophilic and hydrophobic impression materials applied at different impression-making temperatures and with different techniques, the practical relevance is limited.

  17. 21 CFR 872.3660 - Impression material.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3660 Impression material. (a) Identification. Impression material is a device composed of materials such as alginate or polysulfide intended to be placed... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Impression material. 872.3660 Section 872.3660...

  18. 21 CFR 872.6570 - Impression tube.

    Science.gov (United States)

    2010-04-01

    ... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6570 Impression tube. (a) Identification. An impression tube is a device consisting of a hollow copper tube intended to take an impression of a single tooth...) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in...

  19. Irreversible dynamics, Onsager-Casimir symmetry, and an application to turbulence.

    Science.gov (United States)

    Ottinger, Hans Christian

    2014-10-01

    Irreversible contributions to the dynamics of nonequilibrium systems can be formulated in terms of dissipative, or irreversible, brackets. We discuss the structure of such irreversible brackets in view of a degeneracy implied by energy conservation, where we consider different types of symmetries of the bracket corresponding to the Onsager and Casimir symmetries of linear irreversible thermodynamics. Slip and turbulence provide important examples of antisymmetric irreversible brackets and offer guidance for the more general modeling of irreversible dynamics without entropy production. Conversely, turbulence modeling could benefit from elucidating thermodynamic structure. The examples suggest constructing antisymmetric irreversible brackets in terms of completely antisymmetric functions of three indices. Irreversible brackets without well-defined symmetry properties can arise for rare events, causing big configurational changes.

  20. Two-piece impression procedure for implant-retained orbital prostheses.

    Science.gov (United States)

    Ozcelik, Tuncer Burak; Yilmaz, Burak

    2012-01-01

    Obtaining an accurate impression of facial tissues with undercuts and extraoral implants has always been a challenge for both clinicians and patients. This report describes a three-step, two-piece technique that enables an accurate and comfortable impression of undercut tissues and extraoral implants in an orbital defect. An impression of the basal tissue surface of the defect area was made using a medium-body polyether impression material followed by an impression of the entire face of the patient made with a polyvinyl siloxane (PVS) impression material. First, the PVS impression material was removed; second, the impression posts were removed from the magnets; and third, the polyether impression was removed from the defect. The impression posts were attached to the implant analogs and placed in the negative spaces in the polyether impression. The polyether impression, which carries the implant analogs and impression posts, was placed in the PVS impression through the negative spaces. This technique minimizes trauma to the soft tissues and implants during impression making and also does not require additional materials.

  1. Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review.

    Science.gov (United States)

    Ahlholm, Pekka; Sipilä, Kirsi; Vallittu, Pekka; Jakonen, Minna; Kotiranta, Ulla

    2018-01-01

    To conduct a systematic review to evaluate the evidence of possible benefits and accuracy of digital impression techniques vs. conventional impression techniques. Reports of digital impression techniques versus conventional impression techniques were systematically searched for in the following databases: Cochrane Central Register of Controlled Trials, PubMed, and Web of Science. A combination of controlled vocabulary, free-text words, and well-defined inclusion and exclusion criteria guided the search. Digital impression accuracy is at the same level as conventional impression methods in fabrication of crowns and short fixed dental prostheses (FDPs). For fabrication of implant-supported crowns and FDPs, digital impression accuracy is clinically acceptable. In full-arch impressions, conventional impression methods resulted in better accuracy compared to digital impressions. Digital impression techniques are a clinically acceptable alternative to conventional impression methods in fabrication of crowns and short FDPs. For fabrication of implant-supported crowns and FDPs, digital impression systems also result in clinically acceptable fit. Digital impression techniques are faster and can shorten the operation time. Based on this study, the conventional impression technique is still recommended for full-arch impressions. © 2016 by the American College of Prosthodontists.

  2. Hydraulically irreversible fouling on ceramic MF/UF membranes: comparison of fouling indices, foulant composition and irreversible pore narrowing

    KAUST Repository

    Shang, Ran; Vuong, Francois; Hu, Jingyi; Li, Sheng; Kemperman, Antoine J.B.; Nijmeijer, Kitty; Cornelissen, Emile R.; Heijman, Sebastiaan G.J.; Rietveld, Luuk C.

    2015-01-01

    The application of ceramic membranes in water treatment is becoming increasing attractive because of their long life time and excellent chemical, mechanical and thermal stability. However, fouling of ceramic membranes, especially hydraulically irreversible fouling, is still a critical aspect affecting the operational cost and energy consumption in water treatment plants. In this study, four ceramic membranes with pore sizes or molecular weight cut-off (MWCO) of 0.20 μm, 0.14 μm, 300 kDa and 50 kDa were compared during natural surface water filtration with respect to hydraulically irreversible fouling index (HIFI), foulant composition and narrowing of pore size due to the irreversible fouling. Our results showed that the hydraulically irreversible fouling index (HIFI) was proportional to the membrane pore size (r2=0.89) when the same feed water was filtrated. The UF membranes showed lower HIFI values than the MF membranes. Pore narrowing (internal fouling) was found to be a main fouling pattern of the hydraulically irreversible fouling. The internal fouling was caused by monolayer adsorption of foulants with different sizes that is dependent on the size of the membrane pore.

  3. Hydraulically irreversible fouling on ceramic MF/UF membranes: comparison of fouling indices, foulant composition and irreversible pore narrowing

    KAUST Repository

    Shang, Ran

    2015-05-06

    The application of ceramic membranes in water treatment is becoming increasing attractive because of their long life time and excellent chemical, mechanical and thermal stability. However, fouling of ceramic membranes, especially hydraulically irreversible fouling, is still a critical aspect affecting the operational cost and energy consumption in water treatment plants. In this study, four ceramic membranes with pore sizes or molecular weight cut-off (MWCO) of 0.20 μm, 0.14 μm, 300 kDa and 50 kDa were compared during natural surface water filtration with respect to hydraulically irreversible fouling index (HIFI), foulant composition and narrowing of pore size due to the irreversible fouling. Our results showed that the hydraulically irreversible fouling index (HIFI) was proportional to the membrane pore size (r2=0.89) when the same feed water was filtrated. The UF membranes showed lower HIFI values than the MF membranes. Pore narrowing (internal fouling) was found to be a main fouling pattern of the hydraulically irreversible fouling. The internal fouling was caused by monolayer adsorption of foulants with different sizes that is dependent on the size of the membrane pore.

  4. Disinfection of dental impressions - compliance to accepted standards.

    Science.gov (United States)

    Almortadi, N; Chadwick, R G

    2010-12-18

    The responsibility of ensuring impressions have been cleaned and disinfected before dispatch to the dental laboratory lies solely with the dentist. Uncertainty of impression disinfection risks both the health of the receiving dental technician and potential repeat disinfection of an already disinfected impression with detrimental consequences for its dimensions. To ascertain, from the perspectives of dentists and dental technicians, current impression decontamination and disinfection practices with, in the case of the technicians, an estimate of the relative prevalence of contaminated voids within apparently disinfected impressions. Anonymous postal questionnaire. Dentist (n = 200) and dental technician (n = 200) potential participants, selected at random from the registers held by the General Dental Council, were invited to complete an anonymous postal questionnaire that sought to establish current practices and perceived effectiveness of impression disinfection. Questionnaire return rates of 42.1% and 31.2% were recorded for dentists and dental technicians respectively. A wide range of solutions, at different dilutions of the same product, was used by the dentists to disinfect dental impressions. 37.2% rinsed the impressions with water, and 2.6% always brushed debris away, before disinfection. 24.7% of dentists did not inform the laboratory of disinfection. Irrespective of the disinfection status of the received impressions, 50% of the responding dental technicians disinfected all impressions. 95% of them had received blood-contaminated impressions. 15% had encountered blood-filled voids upon trimming back the peripheries of impressions. 64.7% were confident that the impressions received by them had been disinfected by the dentists. Compliance with good practice is less than ideal and education in impression disinfection for both dentists and dental technicians is required to address this.

  5. Impression management as symbolic capital

    DEFF Research Database (Denmark)

    Lueg, Klarissa; Nielsen, Camilla

    2015-01-01

    in Germany and LinkedIn in Denmark. We summarize those differences and relate them to different cultural contexts and impression management practices. Our sample consists of Danish Higher Executives (HEs)/managers (e.g., CEOs) and companies that have profiles on both SNS, thus reaching out to both the German......Social Network Sites (SNS) play an increasingly important role in the European business world, especially with respect to cross-cultural impression management. Departing from the Bourdieusian concept of “capital,” this paper analyzes the differences in the use of two popular business SNS: XING...... and the Danish markets. It is apparent that even business experts operating in both markets could better adapt to the standards and possibilities offered by the German SNS with respect to impression management. We introduce a set of recommendations to foster SNS-related and culture-sensitive impression...

  6. Impression Management and Entrepreneurial Experience

    DEFF Research Database (Denmark)

    Halbinger, Maria; Reichstein, Toke

    2016-01-01

    into entrepreneurship. Analyzing individual-level data collected through online survey, field studies and experiments in hacker-and makerspaces, we find that impression management behavior that focuses others, i.e. accommodative impression management is positively associated with entrepreneurial experience while self...

  7. Evaluation of accuracy of complete-arch multiple-unit abutment-level dental implant impressions using different impression and splinting materials.

    Science.gov (United States)

    Buzayan, Muaiyed; Baig, Mirza Rustum; Yunus, Norsiah

    2013-01-01

    This in vitro study evaluated the accuracy of multiple-unit dental implant casts obtained from splinted or nonsplinted direct impression techniques using various splinting materials by comparing the casts to the reference models. The effect of two different impression materials on the accuracy of the implant casts was also evaluated for abutment-level impressions. A reference model with six internal-connection implant replicas placed in the completely edentulous mandibular arch and connected to multi-base abutments was fabricated from heat-curing acrylic resin. Forty impressions of the reference model were made, 20 each with polyether (PE) and polyvinylsiloxane (PVS) impression materials using the open tray technique. The PE and PVS groups were further subdivided into four subgroups of five each on the bases of splinting type: no splinting, bite registration PE, bite registration addition silicone, or autopolymerizing acrylic resin. The positional accuracy of the implant replica heads was measured on the poured casts using a coordinate measuring machine to assess linear differences in interimplant distances in all three axes. The collected data (linear and three-dimensional [3D] displacement values) were compared with the measurements calculated on the reference resin model and analyzed with nonparametric tests (Kruskal-Wallis and Mann-Whitney). No significant differences were found between the various splinting groups for both PE and PVS impression materials in terms of linear and 3D distortions. However, small but significant differences were found between the two impression materials (PVS, 91 μm; PE, 103 μm) in terms of 3D discrepancies, irrespective of the splinting technique employed. Casts obtained from both impression materials exhibited differences from the reference model. The impression material influenced impression inaccuracy more than the splinting material for multiple-unit abutment-level impressions.

  8. Irreversibility and dissipation in finite-state automata

    International Nuclear Information System (INIS)

    Ganesh, Natesh; Anderson, Neal G.

    2013-01-01

    Irreversibility and dissipation in finite-state automata (FSA) are considered from a physical-information-theoretic perspective. A quantitative measure for the computational irreversibility of finite automata is introduced, and a fundamental lower bound on the average energy dissipated per state transition is obtained and expressed in terms of FSA irreversibility. The irreversibility measure and energy bound are germane to any realization of a deterministic automaton that faithfully registers abstract FSA states in distinguishable states of a physical system coupled to a thermal environment, and that evolves via a sequence of interactions with an external system holding a physical instantiation of a random input string. The central result, which is shown to follow from quantum dynamics and entropic inequalities alone, can be regarded as a generalization of Landauer's Principle applicable to FSAs and tailorable to specified automata. Application to a simple FSA is illustrated.

  9. Extended Irreversible Thermodynamics

    CERN Document Server

    Jou, David

    2010-01-01

    This is the 4th edition of the highly acclaimed monograph on Extended Irreversible Thermodynamics, a theory that goes beyond the classical theory of irreversible processes. In contrast to the classical approach, the basic variables describing the system are complemented by non-equilibrium quantities. The claims made for extended thermodynamics are confirmed by the kinetic theory of gases and statistical mechanics. The book covers a wide spectrum of applications, and also contains a thorough discussion of the foundations and the scope of the current theories on non-equilibrium thermodynamics. For this new edition, the authors critically revised existing material while taking into account the most recent developments in fast moving fields such as heat transport in micro- and nanosystems or fast solidification fronts in materials sciences. Several fundamental chapters have been revisited emphasizing physics and applications over mathematical derivations. Also, fundamental questions on the definition of non-equil...

  10. Impressed by impression management: Newcomer reactions to ingratiated supervisors.

    Science.gov (United States)

    Foulk, Trevor A; Long, David M

    2016-10-01

    Organizational newcomers are unfamiliar with many aspects of their workplace and look for information to help them reduce uncertainty and better understand their new environment. One aspect critical to newcomers is the disposition of their supervisor-the person who arguably can impact the newcomer's career the most. To form an impression of their new supervisor, newcomers look to social cues from coworkers who have interpersonal contact with the supervisor. In the present research, we investigate the ways newcomers use observed ingratiation-a common impression management strategy whereby coworkers try to appear likable (Schlenker, 1980)-to form impressions of a supervisor's warmth. Research on social influence cannot easily account for how third parties will interpret ingratiation, as the behaviors linked to ingratiation suggest something positive about the target, yet the unsavory aspects of the behavior imply it may not have the same effects as other positive behaviors. Our findings suggest that newcomers are unique in that they are motivated to learn about their new supervisor, and are prone to ignore those unsavory aspects and infer something positive about a supervisor targeted with ingratiation. Our findings also suggest that this effect can be weakened based on the supervisor's response. In other words, newcomers rely less on evidence from a coworker's ingratiation in the presence of direct behaviors from the supervisor. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  11. Effect of Storage Time and Temperature on Dimensional Stability of Impressions Made with Zinc Oxide Impression Paste

    Directory of Open Access Journals (Sweden)

    Sareh Habibzadeh

    2016-10-01

    Full Text Available Objectives: This study aimed to assess the effect of storage time and temperature on dimensional stability of impressions made with Cavex Outline zinc oxide impression paste.Materials and Methods: A round stainless steel mold with five grooves (three horizontal and two vertical was used in this in-vitro experimental study. Cavex Outline impression paste was prepared according to the manufacturer’s instructions and applied to the mold. The mold was placed on a block and stored at 35°C and 100% humidity for setting. The impressions were poured with stone immediately and also after 30, 120, 240 and 420 minutes and 24 hours. The distance between the vertical lines on the casts was measured and compared with that in the immediately poured cast.Results: Storage in a refrigerator and at room temperature for zero to seven hours had no significant effect on dimensional stability of the impressions; however, 24 hours of storage in a refrigerator or at room temperature decreased the dimensional stability of Cavex Outline (P=0.001. Also, a significant association was found between dimensional changes following 24 hours of storage in a refrigerator (4°C and at room temperature (23°C; P<0.01.Conclusions: The optimal pouring time of Cavex Outline impressions with stone is between zero to seven hours, and 24 hours of storage significantly decreases the dimensional stability.Keywords: Dental Impression Materials; Zinc Oxide; Cavex

  12. Attribution of irreversible loss to anthropogenic climate change

    Science.gov (United States)

    Huggel, Christian; Bresch, David; Hansen, Gerrit; James, Rachel; Mechler, Reinhard; Stone, Dáithí; Wallimann-Helmer, Ivo

    2016-04-01

    The Paris Agreement (2015) under the UNFCCC has anchored loss and damage in a separate article which specifies that understanding and support should be enhanced in areas addressing loss and damage such as early warning, preparedness, insurance and resilience. Irreversible loss is a special category under loss and damage but there is still missing clarity over what irreversible loss actually includes. Many negative impacts of climate change may be handled or mitigated by existing risk management, reduction and absorption approaches. Irreversible loss, however, is thought to be insufficiently addressed by risk management. Therefore, countries potentially or actually affected by irreversible loss are calling for other measures such as compensation, which however is highly contested in international climate policy. In Paris (2015) a decision was adopted that loss and damage as defined in the respective article of the agreement does not involve compensation and liability. Nevertheless, it is likely that some sort of mechanism will eventually need to come into play for irreversible loss due to anthropogenic climate change, which might involve compensation, other forms of non-monetary reparation, or transformation. Furthermore, climate litigation has increasingly been attempted to address negative effects of climate change. In this context, attribution is important to understand the drivers of change, what counts as irreversible loss due to climate change, and, possibly, who or what is responsible. Here we approach this issue by applying a detection and attribution perspective on irreversible loss. We first analyze detected climate change impacts as assessed in the IPCC Fifth Assessment Report. We distinguish between irreversible loss in physical, biological and human systems, and accordingly identify the following candidates of irreversible loss in these systems: loss of glaciers and ice sheets, loss of subsurface ice (permafrost) and related loss of lake systems; loss

  13. Preliminary impression techniques for microstomia patients

    Directory of Open Access Journals (Sweden)

    K Aswini Kumar

    2016-01-01

    Full Text Available The Prosthetic rehabilitation of microstomia patients presents difficulties at all the stages. The difficulty starts with the preliminary impression making. This is due to the tongue rigidity and the decreased oral opening. A maximum oral opening which is smaller than the size of the tray can make prosthetic treatment challenging. Due to the restricted mouth opening, insertion and removal of the impression trays is extremely cumbersome and various modifications of the trays have been used in the past. Among these are the flexible trays and the sectional trays used with different modes of reassembling the segments extra orally after the impression is made. This article reviews the literature published from 1971 to 2015 concerning preliminary impression techniques used in making impressions for patients with microstomia based on various tray designs. An electronic search was performed across three databases (PubMed, Science Direct and Google Scolar for relevant citations. The keywords/combinations used for the search were microstomia, limited/constricted/restricted mouth opening/oral access, trismus, sectional trays, impressions and prosthetic/prosthodontic rehabilitation. The search was limited to papers written in English which resulted in a total of 45 related articles of which 17 articles were included for discussion of this review.

  14. Impression mismanagement : People as inept self-presenters

    NARCIS (Netherlands)

    Steinmetz, J.F.; Sezer, O.; Sedikides, C.

    2017-01-01

    People routinely manage the impressions they make on others, attempting to project a favorable self-image. The bulk of the literature has portrayed people as savvy self-presenters who typically succeed at conveying a desired impression. When people fail at making a favorable impression, such as when

  15. Effects of Impression Coping Design, Impression Technique, and Dental Undercuts on the Accuracy of Implant Impressions Assessed by 3-Dimensional Optical Scanning: An In Vitro Study.

    Science.gov (United States)

    Sabouhi, Mahmoud; Bajoghli, Farshad; Dakhilalian, Mansour; Beygi, Ali; Abolhasani, Majid

    2016-04-01

    The aim of this in vitro study was to evaluate the effect of the type and design of the impression copings on the accuracy of implant impressions in 2 different conditions. A reference model with 2 implants inserted in bilateral mandibular canines was fabricated. The posterior teeth were inserted as tilted to simulate intra-oral undercuts. The teeth were eliminated to create an edentulous condition. Three different impression techniques were performed (open high retentive [OH], open low retentive [OL], closed [C]) for each condition. Total of 48 casts were made. Two scan-bodies were secured on each cast, scanned by an optical scanner. Then, they were compared to the scan of the reference model, and the calculated mean errors were analyzed with a 2-way ANOVA and Tukey test. There was no significant difference between the complete and partially edentulous groups (F = 3.252, P = 0.079). There was significant difference between the different designs of the impression copings (F = 31.789, P impression copings was more important than the undercuts. The accuracy of the closed tray coping was greater than the low retentive coping and equal to the high retentive coping.

  16. Effects of impression levels and trays on the accuracy of impressions taken from angulated implants.

    Science.gov (United States)

    Geramipanah, Farideh; Sahebi, Majid; Davari, Maryam; Hajimahmoudi, Mohammadreza; Rakhshan, Vahid

    2015-09-01

    It is crucial to keep the misfit of the abutment-fixture unit at the lowest possible rate. There are a few controversial studies on the accuracy of impression making of angulated implants, and much fewer (and controversial) studies on the abutment-level impression technique, which is a convenient and clinically favorable method. Besides, there are no studies on comparison of sectional vs. full-arch trays. We aimed to assess these. A trapezoidal model with four angulated implants installed at 20° and 30° buccal tilts was fabricated. Forty impressions were taken from this model, with two groups of full-arch and sectional custom trays (n = 2 × 20), each divided into two subgroups of implant-level and abutment-level techniques (n = 2 × 2 × 10 in four subgroups). Absolute and non-absolute linear and angular impression errors were estimated by comparing the fabricated casts with the model, using a coordinate measuring machine. The effects of sectional/full-arch trays and abutment-level and fixture-level techniques on impression accuracies were analyzed using one- and two-way analyses of variance (ANOVA), Tukey, Mann-Whitney, and one-sample t-tests (α = 0.05, Mann-Whitney's α using the Bonferroni Bonferroni method). No significant differences between the absolute linear errors of the two trays (P = 0.100 [ANOVA]) and the two levels (P = 0.400 [ANOVA]) were observed. The assessment of absolute angular errors showed no significant differences (all P values ≥ 0.4 [ANOVA]). The difference between the linear errors in the full-arch vs. sectional trays was not significant in the fixture-level group (P = 0.290). However, in the abutment-level group, the linear error was significantly greater in the sectional tray compared to full-arch tray (P = 0.013, α = 0.025 [Mann-Whitney]). Using sectional trays might not be advantageous over full-arch trays. Sectional trays are not recommended for taking abutment-level impressions. The abutment

  17. Downplaying Positive Impressions: Compensation Between Warmth and Competence in Impression Management.

    Science.gov (United States)

    Holoien, Deborah Son; Fiske, Susan T

    2013-01-01

    The compensation effect demonstrates a negative relationship between the dimensions of warmth and competence in impression formation in comparative contexts. However, does compensation between warmth and competence extend to impression management? Two studies examined whether people actively downplay their warmth in order to appear competent and downplay their competence in order to appear warm. In Studies 1a and 1b, participants selected words pretested to be high or low in warmth and competence to include in an e-mail message to people they wanted to impress. As predicted, participants downplayed their competence when they wanted to appear warm (Study 1a) and downplayed their warmth when they wanted to appear competent (Study 1b). In Studies 2a and 2b, compensation also occurred when participants introduced themselves to another person, as evidenced by the questions they selected to answer about themselves, their self-reported goals, and their open-ended introductions. Compensation occurred uniquely between warmth and competence and not for other dimensions, such as healthiness (Study 2a) and political interest (Study 2b), which suggests that the compensation effect extends beyond a mere zero-sum exchange between dimensions.

  18. Neural correlates of self-deception and impression-management.

    Science.gov (United States)

    Farrow, Tom F D; Burgess, Jenny; Wilkinson, Iain D; Hunter, Michael D

    2015-01-01

    Self-deception and impression-management comprise two types of deceptive, but generally socially acceptable behaviours, which are common in everyday life as well as being present in a number of psychiatric disorders. We sought to establish and dissociate the 'normal' brain substrates of self-deception and impression-management. Twenty healthy participants underwent fMRI scanning at 3T whilst completing the 'Balanced Inventory of Desirable Responding' test under two conditions: 'fake good', giving the most desirable impression possible and 'fake bad' giving an undesirable impression. Impression-management scores were more malleable to manipulation via 'faking' than self-deception scores. Response times to self-deception questions and 'fake bad' instructions were significantly longer than to impression-management questions and 'fake good' instructions respectively. Self-deception and impression-management manipulation and 'faking bad' were associated with activation of medial prefrontal cortex (mPFC) and left ventrolateral prefrontal cortex (vlPFC). Impression-management manipulation was additionally associated with activation of left dorsolateral prefrontal cortex and left posterior middle temporal gyrus. 'Faking bad' was additionally associated with activation of right vlPFC, left temporo-parietal junction and right cerebellum. There were no supra-threshold activations associated with 'faking good'. Our neuroimaging data suggest that manipulating self-deception and impression-management and more specifically 'faking bad' engages a common network comprising mPFC and left vlPFC. Shorter response times and lack of dissociable neural activations suggests that 'faking good', particularly when it comes to impression-management, may be our most practiced 'default' mode. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Trends in complete denture impressions in pakistan

    International Nuclear Information System (INIS)

    Vohra, F.; Rashid, H.; Hanif, A.

    2015-01-01

    Multiple materials and techniques have been reported for complete denture impressions in literature. The aim of the study was to assess the trends in complete denture impression materials and techniques among general dental practitioners (GDP) and specialists (SP) in Pakistan. Methods: In this cross-sectional study, self-designed-structured questionnaires were distributed among 500 dentists in Pakistan. The three-part questionnaire enquired about the demographic features, preferred impression materials, impression techniques and related procedures commonly used in their clinical practice. A comparison between the responses of SP and GDP was also drawn. Frequency distribution and Chi-square test were performed to compare the responses. Results: A total of 294 questionnaires were completed at a response rate of 58.8%. 75% of GDP used alginate for primary impressions and 66% of SP preferred impression compound for the same. A majority of both SP and GDP favoured the used of custom trays (SP 81%, GDP 85%) and selective pressure technique (SP 84%, GDP 53%) for final impression. However, 85% of GDP used zinc-oxide eugenol and 62% of SP favoured elastomeric materials for the same. Most of the SP and GDP used chemical cured resin custom trays (SP 54%, GDP 75%), however, 86% of SP used spaced trays and almost 60% of GDP preferred close-fitting trays. Conclusions: The practice of GDP and SP with regards to CD impression materials and techniques differed significantly. Continued education and training for GDP and SP with respect to procedures and techniques related to CD is recommended. (author)

  20. Making a Great First Impression

    Science.gov (United States)

    Evenson, Renee

    2007-01-01

    Managers and business owners often base hiring decisions on first impressions. That is why it is so important to teach students to make a great first impression--before they go on that first job interview. Managers do not have unrealistic expectations, they just want to hire people who they believe can develop into valuable employees. A nice…

  1. Generalized irreversible heat-engine experiencing a complex heat-transfer law

    International Nuclear Information System (INIS)

    Chen Lingen; Li Jun; Sun Fengrui

    2008-01-01

    The fundamental optimal relation between optimal power-output and efficiency of a generalized irreversible Carnot heat-engine is derived based on a generalized heat-transfer law, including a generalized convective heat-transfer law and a generalized radiative heat-transfer law, q ∝ (ΔT n ) m . The generalized irreversible Carnot-engine model incorporates several internal and external irreversibilities, such as heat resistance, bypass heat-leak, friction, turbulence and other undesirable irreversibility factors. The added irreversibilities, besides heat resistance, are characterized by a constant parameter and a constant coefficient. The effects of heat-transfer laws and various loss terms are analyzed. The results obtained corroborate those in the literature

  2. The Bidimensional Impression Management Index (BIMI): measuring agentic and communal forms of impression management.

    Science.gov (United States)

    Blasberg, Sabrina A; Rogers, Katherine H; Paulhus, Delroy L

    2014-01-01

    Measures of impression management have yet to incorporate two-factor models of person perception. The 2 primary factors are often labeled agency and communion. In Study 1, we assembled a new measure of impression management—the Bidimensional Impression Management Index (BIMI): It comprises 2 subscales designed specifically to tap agentic and communal content. Both subscales showed adequate alpha reliabilities under both honest and faking conditions. In Study 2, the BIMI was cross-validated in a new sample: The subscales remained relatively independent, and their reliabilities remained solid. A coherent pattern of personality correlates also supported the validities of both subscales. In Study 3, the differential sensitivity of the 2 subscales was demonstrated by manipulating the job type in simulated job applications. Implications and applications of the BIMI are discussed.

  3. Percutaneous Irreversible Electroporation of a Large Centrally Located Hepatocellular Adenoma in a Woman with a Pregnancy Wish

    International Nuclear Information System (INIS)

    Scheffer, Hester J.; Melenhorst, Marleen C. A. M.; Tilborg, Aukje A. J. M. van; Nielsen, Karin; Nieuwkerk, Karin M. van; Vries, Richard A. de; Tol, Petrousjka van den; Meijerink, Martijn R.

    2015-01-01

    Irreversible electroporation (IRE) is a novel image-guided ablation technique that is rapidly gaining popularity in the treatment of malignant liver tumors located near large vessels or bile ducts. We describe a 28-year-old female patient with a 5 cm large, centrally located hepatocellular adenoma who wished to get pregnant. Regarding the risk of growth and rupture of the adenoma caused by hormonal changes during pregnancy, treatment of the tumor was advised prior to pregnancy. However, due to its central location, the tumor was considered unsuitable for resection and thermal ablation. Percutaneous CT-guided IRE was performed without complications and led to rapid and impressive tumor shrinkage. Subsequent pregnancy and delivery went uncomplicated. This case report suggests that the indication for IRE may extend to the treatment of benign liver tumors that cannot be treated safely otherwise

  4. Percutaneous Irreversible Electroporation of a Large Centrally Located Hepatocellular Adenoma in a Woman with a Pregnancy Wish

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, Hester J., E-mail: hj.scheffer@vumc.nl; Melenhorst, Marleen C. A. M., E-mail: m.melenhorst@vumc.nl; Tilborg, Aukje A. J. M. van, E-mail: a.vantilborg@vumc.nl [VU University Medical Center, Department of Radiology and Nuclear Medicine (Netherlands); Nielsen, Karin, E-mail: k.nielsen@vumc.nl [Department of Surgery (Netherlands); Nieuwkerk, Karin M. van, E-mail: cmj.vannieuwkerk@vumc.nl; Vries, Richard A. de, E-mail: ra.devries@vumc.nl [VU University Medical Center, Department of Gastroenterology and Hepatology (Netherlands); Tol, Petrousjka van den [Department of Surgery (Netherlands); Meijerink, Martijn R., E-mail: mr.meijerink@vumc.nl [VU University Medical Center, Department of Radiology and Nuclear Medicine (Netherlands)

    2015-08-15

    Irreversible electroporation (IRE) is a novel image-guided ablation technique that is rapidly gaining popularity in the treatment of malignant liver tumors located near large vessels or bile ducts. We describe a 28-year-old female patient with a 5 cm large, centrally located hepatocellular adenoma who wished to get pregnant. Regarding the risk of growth and rupture of the adenoma caused by hormonal changes during pregnancy, treatment of the tumor was advised prior to pregnancy. However, due to its central location, the tumor was considered unsuitable for resection and thermal ablation. Percutaneous CT-guided IRE was performed without complications and led to rapid and impressive tumor shrinkage. Subsequent pregnancy and delivery went uncomplicated. This case report suggests that the indication for IRE may extend to the treatment of benign liver tumors that cannot be treated safely otherwise.

  5. Making a Good Impression at Work: National Differences in Employee Impression Management Behaviors in Japan, Korea, and the United States.

    Science.gov (United States)

    Krieg, Alexander; Ma, Li; Robinson, Patricia

    2018-02-17

    Impression management has important implications for success at work. This study explores differences in impression management in the East and West by examining the use of self-promotion, ingratiation, and exemplification directed towards three targets: supervisors, peers, and subordinates among 945 company employees from Japan, Korea, and the United States. Our results show that Korean employees used all three strategies most frequently, followed by United States, and then Japanese employees. Japanese and Korean employees used impression management strategies differentially across the three targets, and U.S. employees used impression management equally across targets. This elucidates how cultural trends in hierarchical relationships impact social behavior within the workplace. A follow-up mediation analysis found that relational or labor mobility fully mediated country differences in impression management, suggesting that culture is also reflected in larger social ecological trends in employee's ability and likelihood to change jobs, which also account for impression management strategy usage. Theoretical and practical implications for international business are discussed. This research may be useful in aligning strategies foreign employees might employ for using impression management when in Japan, Korea, and the United States.

  6. Absorption media for irreversibly gettering thionyl chloride

    Science.gov (United States)

    Buffleben, George; Goods, Steven H.; Shepodd, Timothy; Wheeler, David R.; Whinnery, Jr., LeRoy

    2002-01-01

    Thionyl chloride is a hazardous and reactive chemical used as the liquid cathode in commercial primary batteries. Contrary to previous thinking, ASZM-TEDA.RTM. carbon (Calgon Corporation) reversibly absorbs thionyl chloride. Thus, several candidate materials were examined as irreversible getters for thionyl chloride. The capacity, rate and effect of temperature were also explored. A wide variety of likely materials were investigated through screening experiments focusing on the degree of heat generated by the reaction as well as the material absorption capacity and irreversibility, in order to help narrow the group of possible getter choices. More thorough, quantitative measurements were performed on promising materials. The best performing getter was a mixture of ZnO and ASZM-TEDA.RTM. carbon. In this example, the ZnO reacts with thionyl chloride to form ZnCl.sub.2 and SO.sub.2. The SO.sub.2 is then irreversibly gettered by ASZM-TEDA.RTM. carbon. This combination of ZnO and carbon has a high capacity, is irreversible and functions effectively above -20.degree. C.

  7. The Value of Fighting Irreversible Demise by Softening the Irreversible Cost

    NARCIS (Netherlands)

    Magis, P.; Sbuelz, A.

    2005-01-01

    We study a novel issue in the real-options-based technology innovation literature by means of double barrier contingent claims analysis.We show how much a ¯rm with the monopoly over a project is willing to spend in investment technology innovation that softens the irreversible cost of accessing the

  8. Irreversible work in a thermal medium with colored noise

    International Nuclear Information System (INIS)

    Ohkuma, Takahiro

    2009-01-01

    Irreversible work and its fluctuations in a classical system governed by non-Markovian stochastic dynamics are investigated. The production of irreversible work depends not only on the protocol of an operation but also on the details of the non-Markovian memory. We consider a generalized Langevin equation with a memory kernel and derive an expression for the irreversible work in the case of slow operations by carrying out an expansion of this memory kernel in the parameter representing the length of the memory. We apply our formulation to a harmonically trapped system and demonstrate the efficiency of a cycle by evaluating the irreversible work. It is found that a decrease in the irreversible work due to the memory effect can occur for an operation through which the trap is squeezed. The results for this harmonic system are verified exactly in the case that the memory kernel has exponential decay

  9. Irreversible work in a thermal medium with colored noise

    Science.gov (United States)

    Ohkuma, Takahiro

    2009-10-01

    Irreversible work and its fluctuations in a classical system governed by non-Markovian stochastic dynamics are investigated. The production of irreversible work depends not only on the protocol of an operation but also on the details of the non-Markovian memory. We consider a generalized Langevin equation with a memory kernel and derive an expression for the irreversible work in the case of slow operations by carrying out an expansion of this memory kernel in the parameter representing the length of the memory. We apply our formulation to a harmonically trapped system and demonstrate the efficiency of a cycle by evaluating the irreversible work. It is found that a decrease in the irreversible work due to the memory effect can occur for an operation through which the trap is squeezed. The results for this harmonic system are verified exactly in the case that the memory kernel has exponential decay.

  10. Irreversible thermodynamic analysis and application for molecular heat engines

    Science.gov (United States)

    Lucia, Umberto; Açıkkalp, Emin

    2017-09-01

    Is there a link between the macroscopic approach to irreversibility and microscopic behaviour of the systems? Consumption of free energy keeps the system away from a stable equilibrium. Entropy generation results from the redistribution of energy, momentum, mass and charge. This concept represents the essence of the thermodynamic approach to irreversibility. Irreversibility is the result of the interaction between systems and their environment. The aim of this paper is to determine lost works in a molecular engine and compare results with macro (classical) heat engines. Firstly, irreversible thermodynamics are reviewed for macro and molecular cycles. Secondly, irreversible thermodynamics approaches are applied for a quantum heat engine with -1/2 spin system. Finally, lost works are determined for considered system and results show that macro and molecular heat engines obey same limitations. Moreover, a quantum thermodynamic approach is suggested in order to explain the results previously obtained from an atomic viewpoint.

  11. Exergetic efficiency optimization for an irreversible heat pump ...

    Indian Academy of Sciences (India)

    side ... For irreversible cycle, the internal irreversibility, i.e., non-isentropic losses in the ... constant thermal capacitance rate (the product of mass flow rate and specific heat), .... reversed Brayton cycle is dependent on the external heat transfer ...

  12. Burger or yogurt? Indulgent consumption in impression management contexts.

    Science.gov (United States)

    Cheng, Yin-Hui; Huang, Molly C-J; Chuang, Shih-Chieh; Ju, Ying Rung

    2015-10-01

    We conducted three studies to investigate indulgent choice in settings with and without impression management by public-private manipulation with evaluation. Study 1 showed that the participants were less indulgent under public scrutiny due to the employment of impression management. Study 2 focused on the impression management context to test the moderate effect of self-consciousness in two impression managed contexts. Study 3 focused on context without impression management to test the moderate effects of self-awareness on choices. We found that depending on differences in primed personality, individuals tended to make choices other than those they favoured privately when anticipating that others might form impressions of them based on the decisions made. The findings of all three studies support our basic prediction that people are less indulgent under impression management and suggest that people tend to manage their impression by eating healthier (less indulgently) in public. © 2014 International Union of Psychological Science.

  13. The detection of local irreversibility in time series based on segmentation

    Science.gov (United States)

    Teng, Yue; Shang, Pengjian

    2018-06-01

    We propose a strategy for the detection of local irreversibility in stationary time series based on multiple scale. The detection is beneficial to evaluate the displacement of irreversibility toward local skewness. By means of this method, we can availably discuss the local irreversible fluctuations of time series as the scale changes. The method was applied to simulated nonlinear signals generated by the ARFIMA process and logistic map to show how the irreversibility functions react to the increasing of the multiple scale. The method was applied also to series of financial markets i.e., American, Chinese and European markets. The local irreversibility for different markets demonstrate distinct characteristics. Simulations and real data support the need of exploring local irreversibility.

  14. First Impressions.

    Science.gov (United States)

    Coen, Frank

    1969-01-01

    The unreliability of first impressions and subjective judgments is the subject of both Jane Austen's "Pride and Prejudice" and Lionel Trilling's "Of This Time, Of That Place"; consequently, the works are worthwhile parallel studies for high school students. Austen, by means of irony and subtle characterization, dramatizes the…

  15. [The global impression technic in fixed dentures].

    Science.gov (United States)

    Lamy, M; Mainjot, A

    2001-01-01

    The global impression technique allows to obtain in a single stage the impression of the abutment as well as their neighboring teeth. This technique often requires the placement of one or two retraction cords in the sulcus. The impression technique herein described is the double mix method. This method is based on the use of two elastomers with different viscosities, but from the same group thus allowing a simultaneous polymerization.

  16. Single Visit Feeding Appliance for 1-day-old Neonate with Cleft Palate Using Safe Dental Putty-Gauze Hybrid Impression Technique for Maxillary Impression.

    Science.gov (United States)

    Rathee, Manu

    2015-01-01

    Cleft lip and palate is one of the most common craniofacial anomalies of humans. Intraoral impression making is the first clinical step in the fabrication of feeding appliance for infants with oro-nasal communication. It is difficult to control the flow of the impression material in the cleft area and undercuts in a child patient. This clinical report presents a simple and safe impression technique for maxillary impression making in neonates and infants with cleft palate. A gauze piece was used to confine the impression material during functional movements of sucking while impression making in an awake child to avoid the risk of aspiration or swallowing.

  17. A simple method for fabricating custom sectional impression trays for making definitive impressions in patients with microstomia

    OpenAIRE

    Bachhav, Vinay Chila; Aras, Meena Ajay

    2012-01-01

    Objective: A maximum mouth opening that is smaller than the size of a complete denture can make prosthetic treatment challenging. This article describes a simple technique used to fabricate maxillary and mandibular custom sectional impression trays for making definitive impressions in patients with microstomia.

  18. Digital versus conventional implant impressions for edentulous patients: accuracy outcomes.

    Science.gov (United States)

    Papaspyridakos, Panos; Gallucci, German O; Chen, Chun-Jung; Hanssen, Stijn; Naert, Ignace; Vandenberghe, Bart

    2016-04-01

    To compare the accuracy of digital and conventional impression techniques for completely edentulous patients and to determine the effect of different variables on the accuracy outcomes. A stone cast of an edentulous mandible with five implants was fabricated to serve as master cast (control) for both implant- and abutment-level impressions. Digital impressions (n = 10) were taken with an intraoral optical scanner (TRIOS, 3shape, Denmark) after connecting polymer scan bodies. For the conventional polyether impressions of the master cast, a splinted and a non-splinted technique were used for implant-level and abutment-level impressions (4 cast groups, n = 10 each). Master casts and conventional impression casts were digitized with an extraoral high-resolution scanner (IScan D103i, Imetric, Courgenay, Switzerland) to obtain digital volumes. Standard tessellation language (STL) datasets from the five groups of digital and conventional impressions were superimposed with the STL dataset from the master cast to assess the 3D (global) deviations. To compare the master cast with digital and conventional impressions at the implant level, analysis of variance (ANOVA) and Scheffe's post hoc test was used, while Wilcoxon's rank-sum test was used for testing the difference between abutment-level conventional impressions. Significant 3D deviations (P impressions (P > 0.001). Digital implant impressions are as accurate as conventional implant impressions. The splinted, implant-level impression technique is more accurate than the non-splinted one for completely edentulous patients, whereas there was no difference in the accuracy at the abutment level. The implant angulation up to 15° did not affect the accuracy of implant impressions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. General thermodynamic performance of irreversible absorption heat pump

    International Nuclear Information System (INIS)

    Zhao Xiling; Fu Lin; Zhang Shigang

    2011-01-01

    The absorption heat pump (AHP) was studied with thermodynamics. A four reservoirs model of absorption heat pump was established considering the heat resistance, heat leak and the internal irreversibility. The reasonable working regions, the performance effects of irreversibility, heat leak and the correlation of four components were studied. When studying the effects of internal irreversibility, two internal irreversibility parameters (I he for generator-absorber assembly and I re for evaporator-condenser assembly) were introduced to distinguish the different effects. When studying the heat transfer relations of four components, a universal relationship between the main parameters were deduced. The results which have more realized meaning show that, the reduction of the friction, heat loss, and internal dissipations of the evaporator-condenser assembly are more important than its reduction of generator-absorber assembly, and lessening the heat leak of generator are more important than its reduction of other components to improve the AHP performance.

  20. Effects of Music on Image Impression and Relationship between Impression and Physical Properties

    Science.gov (United States)

    Sato, Keiko; Mitsukura, Yasue

    Auditory information plays an integral role in AV media because even identical images are perceived differently when they are matched with different music. However, we now present a few studies in which the changes in subjective perceptions were analyzed on the basis of the physical properties of the perceived items. The purpose of this study is to investigate the effects of music on image impression in terms of the physical properties of images. In this paper, we first elucidate the changes in subjective impressions when the image is presented by itself and when it is presented with music. Secondly, to clarify the relation between the impression of an image or music and physical properties, we compare the different image or music perceptions with each other and also compare their respective physical properties, which include color information, structural information, and frequency characteristics. As a result, the color information of an image containing green or saturation colors and the power of the music were strongly correlated with adjectives expressing activity. Moreover, the entropy of saturation correlated with words expressing spatial extent.

  1. Dimensional accuracy of digital dental models from cone-beam computed tomography scans of alginate impressions according to time elapsed after the impressions.

    Science.gov (United States)

    Lee, Sang-Mi; Hou, Yanan; Cho, Jin-Hyoung; Hwang, Hyeon-Shik

    2016-02-01

    Our objective was to investigate the dimensional accuracy of digital dental models obtained from the cone-beam computed tomography (CBCT) scans of alginate impressions according to the time elapsed after the impressions were taken. Alginate impressions were obtained of 20 adults using 2 alginate materials: Alginoplast (Heraeus Kulzer, Hanau, Germany) and Cavex (Cavex Holland, Haarlem, The Netherlands). These impressions were stored in wet conditions and scanned by CBCT immediately after impression-taking and after storage times of 12, 24, 36, 48, 60, and 72 hours. After reconstruction of the 3-dimensional digital dental models, the models were measured, and the data were analyzed to determine the dimensional changes according to the time elapsed. The changes within the measurement error were regarded as clinically acceptable in this study. The measurement errors ranged from 0.27 to 0.29 mm in the digital dental models obtained from CBCT scans of the alginate impressions. All measurements showed decreasing accuracy with greater elapsed time after the impressions were taken. Changes above the measurement error occurred at 24 and 36 hours for Cavex and Alginoplast, respectively. Digital dental models can be obtained from CBCT scans of alginate impressions without sending them to a remote laboratory. However, the impressions need to be scanned within 24 hours; otherwise, dimensional changes lead to errors that exceed the error of measurement. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  2. 21 CFR 872.3670 - Resin impression tray material.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resin impression tray material. 872.3670 Section...

  3. Stochastic dynamics and irreversibility

    CERN Document Server

    Tomé, Tânia

    2015-01-01

    This textbook presents an exposition of stochastic dynamics and irreversibility. It comprises the principles of probability theory and the stochastic dynamics in continuous spaces, described by Langevin and Fokker-Planck equations, and in discrete spaces, described by Markov chains and master equations. Special concern is given to the study of irreversibility, both in systems that evolve to equilibrium and in nonequilibrium stationary states. Attention is also given to the study of models displaying phase transitions and critical phenomema both in thermodynamic equilibrium and out of equilibrium. These models include the linear Glauber model, the Glauber-Ising model, lattice models with absorbing states such as the contact process and those used in population dynamic and spreading of epidemic, probabilistic cellular automata, reaction-diffusion processes, random sequential adsorption and dynamic percolation. A stochastic approach to chemical reaction is also presented.The textbook is intended for students of ...

  4. Irreversible stochastic processes on lattices

    International Nuclear Information System (INIS)

    Nord, R.S.

    1986-01-01

    Models for irreversible random or cooperative filling of lattices are required to describe many processes in chemistry and physics. Since the filling is assumed to be irreversible, even the stationary, saturation state is not in equilibrium. The kinetics and statistics of these processes are described by recasting the master equations in infinite hierarchical form. Solutions can be obtained by implementing various techniques: refinements in these solution techniques are presented. Programs considered include random dimer, trimer, and tetramer filling of 2D lattices, random dimer filling of a cubic lattice, competitive filling of two or more species, and the effect of a random distribution of inactive sites on the filling. Also considered is monomer filling of a linear lattice with nearest neighbor cooperative effects and solve for the exact cluster-size distribution for cluster sizes up to the asymptotic regime. Additionally, a technique is developed to directly determine the asymptotic properties of the cluster size distribution. Finally cluster growth is considered via irreversible aggregation involving random walkers. In particular, explicit results are provided for the large-lattice-size asymptotic behavior of trapping probabilities and average walk lengths for a single walker on a lattice with multiple traps. Procedures for exact calculation of these quantities on finite lattices are also developed

  5. Can we measure patients' perception during dental impressions? The Burdens in Dental Impression-Making Questionnaire - BiDIM-Q.

    Science.gov (United States)

    Tsirogiannis, Panagiotis; Neophytou, Sophia; Reul, Anika; Heydecke, Guido; Reissmann, Daniel R

    2017-01-01

    To develop a reliable and valid instrument for the comprehensive assessment of patients' burdens during dental impression making, the Burdens in Dental Impression Making Questionnaire, BiDIM-Q. The item pool was generated in a convenience sample of 20 prosthodontic patients using semi-structured face-to-face interviews. The final instrument was tested in 145 consecutively recruited patients, and psychometric properties of the BiDIM-Q were determined. Four different impression materials were used according to the manufacturers' instructions and indications: alginate, c-silicone, polyvinylsiloxane, and polyether. The final BiDIM-Q consisting of 12 items showed sufficient reliability, indicated by Cronbach's alpha of .82 and an average inter-item correlation of .29. Validity was supported by Pearson correlation coefficients for the correlation between the instrument's total score with the patients' overall satisfaction rating (r=.63), and by the correlation matrix for the correlations of the patients' perceptions with the practitioners' satisfaction ratings. Overall, patient perceived burdens were low with highest burdens observed when using polyether in partially dentate patients for pick-up impressions, while lowest burdens were reported when using c-silicone for impressions of edentulous jaws. The BiDIM-Q is a reliable and valid tool for assessing patient-based process-related quality of care in dentistry allowing a deeper insight into patients' perspective during dental impression making. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  6. Role of hydrocolloid dressings in the treatment of moist skin desquamation

    International Nuclear Information System (INIS)

    Margolin, S.G.

    1987-01-01

    Moist skin desquamation has been of concern to radiation oncologists since the inception of radiation therapy as a major treatment modality. As treatment units became more sophisticated severe skin reactions became less of a problem, but never disappeared. In recent years, with the more aggressive use of chemotherapy concurrently with radiation therapy, and with some treatment regimens requiring high doses to the skin, moist desquamation has occurred more frequently. The principle of wound healing under occlusive moist conditions is based on the observation that untouched blisters showed faster reepithelialization than open blisters. As long ago as 1962, it was demonstrated that if tissue hydration were maintained the rate of epidermal resurfacing would be enhanced. The primary disadvantage has been the fear of infection. Since June 1984, the authors have treated 40 patients with moist desquamation with an occlusive hydrocolloid dressing. These patients had undergone radiation therapy for a variety of conditions, including Hodgkin disease, head and neck cancers, melanoma, and breast cancer. Some patients had received concurrent chemotherapy and experienced severe reactions. All patients healed well with good cosmesis, and there were no infections. Pain relief was excellent. This exhibit demonstrates the theory of moist occlusive healing. Dressing application and case history pictures illustrating the healing process are shown

  7. Irreversible thermodynamics of Poisson processes with reaction.

    Science.gov (United States)

    Méndez, V; Fort, J

    1999-11-01

    A kinetic model is derived to study the successive movements of particles, described by a Poisson process, as well as their generation. The irreversible thermodynamics of this system is also studied from the kinetic model. This makes it possible to evaluate the differences between thermodynamical quantities computed exactly and up to second-order. Such differences determine the range of validity of the second-order approximation to extended irreversible thermodynamics.

  8. Lifting bloody footwear impressions using alginate casts followed by chemical enhancement.

    Science.gov (United States)

    Wiesner, Sarena; Izraeli, Elad; Shor, Yaron; Domb, Avi

    2013-05-01

    A method for lifting bloody footwear impressions using alginate casts and enhancing the lifted impressions with amido black is presented. On rough or dark substrates, background interferences may conceal significant details of footwear impressions. Illumination with alternative light sources and chemically enhancing the bloody footwear impressions may reveal additional details, but sometimes, lifting footwear impressions prior to enhancing is the only way to expose hidden details (by using blood reagents not adequate on the original). Several cast formulations were tested for lifting the footwear impressions. The best results were achieved using Aroma fine®. Enhancement of the footwear impressions was attempted with several reagents prior to lifting, during the casting process, and on the lifted footwear impressions. Applying amido black to footwear impressions lifted with alginate produced the sharpest and most detailed footwear impressions. Alginate castings followed by chemical enhancement with amido black may produce high-quality footwear impressions for comparison. © 2013 American Academy of Forensic Sciences.

  9. Thermodynamic Analysis of an Irreversible Maisotsenko Reciprocating Brayton Cycle

    Directory of Open Access Journals (Sweden)

    Fuli Zhu

    2018-03-01

    Full Text Available An irreversible Maisotsenko reciprocating Brayton cycle (MRBC model is established using the finite time thermodynamic (FTT theory and taking the heat transfer loss (HTL, piston friction loss (PFL, and internal irreversible losses (IILs into consideration in this paper. A calculation flowchart of the power output (P and efficiency (η of the cycle is provided, and the effects of the mass flow rate (MFR of the injection of water to the cycle and some other design parameters on the performance of cycle are analyzed by detailed numerical examples. Furthermore, the superiority of irreversible MRBC is verified as the cycle and is compared with the traditional irreversible reciprocating Brayton cycle (RBC. The results can provide certain theoretical guiding significance for the optimal design of practical Maisotsenko reciprocating gas turbine plants.

  10. Antibiotic use for irreversible pulpitis.

    Science.gov (United States)

    Agnihotry, Anirudha; Fedorowicz, Zbys; van Zuuren, Esther J; Farman, Allan G; Al-Langawi, Jassim Hasan

    2016-02-17

    Irreversible pulpitis, which is characterised by acute and intense pain, is one of the most frequent reasons that patients attend for emergency dental care. Apart from removal of the tooth, the customary way of relieving the pain of irreversible pulpitis is by drilling into the tooth, removing the inflamed pulp (nerve) and cleaning the root canal. However, a significant number of dentists continue to prescribe antibiotics to stop the pain of irreversible pulpitis.This review updates the previous version published in 2013. To assess the effects of systemic antibiotics for irreversible pulpitis. We searched the Cochrane Oral Health Group's Trials Register (to 27 January 2016); the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2015, Issue 12); MEDLINE via Ovid (1946 to 27 January 2016); EMBASE via Ovid (1980 to 27 January 2016), ClinicalTrials.gov (to 27 January 2016) and the WHO International Clinical Trials Registry Platform (to 27 January 2016). There were no language restrictions in the searches of the electronic databases. Randomised controlled trials which compared pain relief with systemic antibiotics and analgesics, against placebo and analgesics in the acute preoperative phase of irreversible pulpitis. Two review authors screened studies and extracted data independently. We assessed the quality of the evidence of included studies using GRADEpro software. Pooling of data was not possible and a descriptive summary is presented. One trial assessed at low risk of bias, involving 40 participants was included in this update of the review. The quality of the body of evidence was rated low for the different outcomes. There was a close parallel distribution of the pain ratings in both the intervention and placebo groups over the seven-day study period. There was insufficient evidence to claim or refute a benefit for penicillin for pain intensity. There was no significant difference in the mean total number of ibuprofen tablets over the

  11. Optimization of an irreversible Stirling regenerative cycle

    International Nuclear Information System (INIS)

    Aragón-González, G; Cano-Bianco, M; León-Galicia, A; Rivera-Camacho, J M

    2015-01-01

    In this work a Stirling regenerative cycle with some irreversibilities is analyzed. The analyzed irreversibilities are located at the heat exchangers. They receive a finite amount of heat and heat leakage occurs between both reservoirs. Using this model, power and the efficiency at maximum power are obtained. Some optimal design parameters for the exchanger heat areas and thermal conductances are presented. The relation between the power, efficiency and the results obtained are shown graphically

  12. Assessing the accuracy of elastomeric Impression materials in reline method

    OpenAIRE

    MH. Shahrodi; M. Emamie

    1995-01-01

    The accuracy of relined impressions is usually acceptable and in some cases is even more accurate than principal impression. Relined Polysulfide and condensational silicone impressions are more accurate than polyether impressions. The reline method compared to retaking them is more economic and needs less chair time.

  13. Reversible and irreversible heat engine and refrigerator cycles

    Science.gov (United States)

    Leff, Harvey S.

    2018-05-01

    Although no reversible thermodynamic cycles exist in nature, nearly all cycles covered in textbooks are reversible. This is a review, clarification, and extension of results and concepts for quasistatic, reversible and irreversible processes and cycles, intended primarily for teachers and students. Distinctions between the latter process types are explained, with emphasis on clockwise (CW) and counterclockwise (CCW) cycles. Specific examples of each are examined, including Carnot, Kelvin and Stirling cycles. For the Stirling cycle, potentially useful task-specific efficiency measures are proposed and illustrated. Whether a cycle behaves as a traditional refrigerator or heat engine can depend on whether it is reversible or irreversible. Reversible and irreversible-quasistatic CW cycles both satisfy Carnot's inequality for thermal efficiency, η ≤ η C a r n o t . Irreversible CCW cycles with two reservoirs satisfy the coefficient of performance inequality K ≤ K C a r n o t . However, an arbitrary reversible cycle satisfies K ≥ K C a r n o t when compared with a reversible Carnot cycle operating between its maximum and minimum temperatures, a potentially counterintuitive result.

  14. Accuracy of implant transfer with open-tray and closed-tray impression techniques and surface detail reproduction of the tooth during impression

    Directory of Open Access Journals (Sweden)

    Hakimeh Siadat

    2012-01-01

    Full Text Available Background and Aims: Accurate recording of implant location is required to achieve passive fit and have the implants without stress concentration. The aim of this in-vitro study was to evaluate the dimensional and angular accuracy of open-tray and closed-tray impression techniques using polyether impression material and also to assess the surface detail reproduction of the tooth while impression making.Materials and Methods: One reference metal model with 2 implants (Implantium on the position of the maxillary second premolar and first molar and one molar tooth for evaluation of surface details was prepared. 27 polyether impressions of these models were made (9 using open-tray, 9 using closed-tray techniques and 9 were made just of the surface of the teeth without any implants. Impressions were poured with ADA type IV stone. Coordinate Measuring Machine was used for measuring the dimensional accuracy and video measuring machine for surface detail reproduction. All of these measurements were compared with the measurements on the reference model. Data were analyzed by and compared by T-test and One-way ANOVA.Results: There was a significant statistical difference between open-tray and closed-tray techniques (P0.05.Conclusion: The accuracy of open-tray impression technique was more than closed-tray technique. The surface detail reproduction of the tooth was not affected by impression technique.

  15. A Validation Study of the Impression Replica Technique.

    Science.gov (United States)

    Segerström, Sofia; Wiking-Lima de Faria, Johanna; Braian, Michael; Ameri, Arman; Ahlgren, Camilla

    2018-04-17

    To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 μm. The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry. © 2018 by the American College of Prosthodontists.

  16. Full arch scans: conventional versus digital impressions--an in-vitro study.

    Science.gov (United States)

    Ender, A; Mehl, A

    2011-01-01

    The digital intraoral impression has become a central part of the CAD/CAM technique. The objective of the present study was to compare the accuracy (trueness and precision) of digital impressions of the full arch with that of conventional impressions on the in-vitro model. For this purpose, a master model was acquired with a new reference scanning process, the measuring trueness of which was +/- 4.1 microm and the precision +/- 2.5 microm. On the one hand, conventional impressions and then plaster models (n = 5) were produced from this master model, and on the other hand, digital impressions were made with the Cerec AC Bluecam and the Lava COS system (each n = 5). The plaster models were also scanned with the reference scanner. The available data records were superimposed and the differences determined. The deviation from the master model defines the trueness of the impression method. The deviations of the models among one another demonstrate the precision of the method. The trueness of the impressions was 55 +/- 21.8 microm in the conventional impression group, for digital impressions with Cerec Bluecam it was 49 +/- 14.2 microm and for digital impressions with Lava COS 40.3 +/- 14.1 microm. The precision was 61.3 +/- 17.9 microm for conventional impression with Impregum, 30.9 +/- 7.1 microm for digital impression with the Cerec Bluecam and 60.1 +/- 31.3 microm for digital impression with Lava COS. These in-vitro results show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

  17. Formation of Irreversible H-bonds in Cellulose Materials

    Science.gov (United States)

    Umesh P. Agarwal; Sally A. Ralph; Rick S. Reiner; Nicole M. Stark

    2015-01-01

    Understanding of formation of irreversible Hbonds in cellulose is important in a number of fields. For example, fields as diverse as pulp and paper and enzymatic saccharification of cellulose are affected. In the present investigation, the phenomenon of formation of irreversible H-bonds is studied in a variety of celluloses and under two different drying conditions....

  18. The effects of irreversible electroporation (IRE on nerves.

    Directory of Open Access Journals (Sweden)

    Wei Li

    Full Text Available BACKGROUND: If a critical nerve is circumferentially involved with tumor, radical surgery intended to cure the cancer must sacrifice the nerve. Loss of critical nerves may lead to serious consequences. In spite of the impressive technical advancements in nerve reconstruction, complete recovery and normalization of nerve function is difficult to achieve. Though irreversible electroporation (IRE might be a promising choice to treat tumors near or involved critical nerve, the pathophysiology of the nerve after IRE treatment has not be clearly defined. METHODS: We applied IRE directly to a rat sciatic nerve to study the long term effects of IRE on the nerve. A sequence of 10 square pulses of 3800 V/cm, each 100 µs long was applied directly to rat sciatic nerves. In each animal of group I (IRE the procedure was applied to produce a treated length of about 10 mm. In each animal of group II (Control the electrodes were only applied directly on the sciatic nerve for the same time. Electrophysiological, histological, and functional studies were performed on immediately after and 3 days, 1 week, 3, 5, 7 and 10 weeks following surgery. FINDINGS: Electrophysiological, histological, and functional results show the nerve treated with IRE can attain full recovery after 7 weeks. CONCLUSION: This finding is indicative of the preservation of nerve involving malignant tumors with respect to the application of IRE pulses to ablate tumors completely. In summary, IRE may be a promising treatment tool for any tumor involving nerves.

  19. A rare allergy to a polyether dental impression material.

    Science.gov (United States)

    Mittermüller, Pauline; Szeimies, Rolf-Markus; Landthaler, Michael; Schmalz, Gottfried

    2012-08-01

    Polyether impression materials have been used in dentistry for more than 40 years. Allergic reactions to these materials such as reported in the 1970s ceased after replacement of a catalyst. Very recently, however, patients have started to report symptoms that suggest a new allergic reaction from polyether impression materials. Here, we report on the results of allergy testing with polyether impression materials as well as with its components. Eight patients with clinical symptoms of a contact allergy (swelling, redness or blisters) after exposure to a polyether impression material were subjected to patch tests, two of them additionally to a prick test. A further patient with atypical symptoms of an allergy (nausea and vomiting after contact with a polyether impression material in the oral cavity) but with a history of other allergic reaction was also patch tested. The prick tests showed no immediate reactions in the two patients tested. In the patch tests, all eight patients with typical clinical symptoms showed positive reactions to the mixed polyether impression materials, to the base paste or to a base paste component. The patient with the atypical clinical symptoms did not show any positive patch test reactions. Polyether impression materials may evoke type IV allergic reactions. The causative agent was a component of the base paste. In consideration of the widespread use of this impression material (millions of applications per year) and in comparison to the number of adverse reactions from other dental materials, the number of such allergic reactions is very low. In very scarce cases, positive allergic reactions to polyether impression materials are possible.

  20. Irreversible climate change due to carbon dioxide emissions

    Science.gov (United States)

    Solomon, Susan; Plattner, Gian-Kasper; Knutti, Reto; Friedlingstein, Pierre

    2009-01-01

    The severity of damaging human-induced climate change depends not only on the magnitude of the change but also on the potential for irreversibility. This paper shows that the climate change that takes place due to increases in carbon dioxide concentration is largely irreversible for 1,000 years after emissions stop. Following cessation of emissions, removal of atmospheric carbon dioxide decreases radiative forcing, but is largely compensated by slower loss of heat to the ocean, so that atmospheric temperatures do not drop significantly for at least 1,000 years. Among illustrative irreversible impacts that should be expected if atmospheric carbon dioxide concentrations increase from current levels near 385 parts per million by volume (ppmv) to a peak of 450–600 ppmv over the coming century are irreversible dry-season rainfall reductions in several regions comparable to those of the “dust bowl” era and inexorable sea level rise. Thermal expansion of the warming ocean provides a conservative lower limit to irreversible global average sea level rise of at least 0.4–1.0 m if 21st century CO2 concentrations exceed 600 ppmv and 0.6–1.9 m for peak CO2 concentrations exceeding ≈1,000 ppmv. Additional contributions from glaciers and ice sheet contributions to future sea level rise are uncertain but may equal or exceed several meters over the next millennium or longer. PMID:19179281

  1. Impression Management Training: Conceptualization and Application to Personal Selling.

    Science.gov (United States)

    Leathers, Dale G.

    1988-01-01

    Discusses the importance of impression management, an individual's conscious attempt to exercise control over selected communicative behaviors and cues for purposes of making a desired impression. Provides a comprehensive conceptualization of the impression-management process, and demonstrates how this process can facilitate effective training of…

  2. Social relevance enhances memory for impressions in older adults.

    Science.gov (United States)

    Cassidy, Brittany S; Gutchess, Angela H

    2012-01-01

    Previous research has demonstrated that older adults have difficulty retrieving contextual material over items alone. Recent research suggests this deficit can be reduced by adding emotional context, allowing for the possibility that memory for social impressions may show less age-related decline than memory for other types of contextual information. Two studies investigated how orienting to social or self-relevant aspects of information contributed to the learning and retrieval of impressions in young and older adults. Participants encoded impressions of others in conditions varying in the use of self-reference (Experiment 1) and interpersonal meaningfulness (Experiment 2), and completed memory tasks requiring the retrieval of specific traits. For both experiments, age groups remembered similar numbers of impressions. In Experiment 1 using more self-relevant encoding contexts increased memory for impressions over orienting to stimuli in a non-social way, regardless of age. In Experiment 2 older adults had enhanced memory for impressions presented in an interpersonally meaningful relative to a personally irrelevant way, whereas young adults were unaffected by this manipulation. The results provide evidence that increasing social relevance ameliorates age differences in memory for impressions, and enhances older adults' ability to successfully retrieve contextual information.

  3. Intrinsic irreversibility in quantum theory

    International Nuclear Information System (INIS)

    Prigogine, I.; Petrosky, T.Y.

    1987-01-01

    Quantum theory has a dual structure: while solutions of the Schroedinger equation evolve in a deterministic and time reversible way, measurement introduces irreversibility and stochasticity. This presents a contrast to Bohr-Sommerfeld-Einstein theory, in which transitions between quantum states are associated with spontaneous and induced transitions, defined in terms of stochastic processes. A new form of quantum theory is presented here, which contains an intrinsic form of irreversibility, independent of observation. This new form applies to situations corresponding to a continuous spectrum and to quantum states with finite life time. The usual non-commutative algebra associated to quantum theory is replaced by more general algebra, in which operators are also non-distributive. Our approach leads to a number of predictions, which hopefully may be verified or refuted in the next years. (orig.)

  4. Impression Management and Organizational Performance: the Portuguese case

    OpenAIRE

    Borges, Maria de Fátima Ribeiro

    2013-01-01

    This study assesses the influence of performance in the adoption of impression management strategies. The study conducts a content analysis of a sample of 45 chairman’s statements, included in the annual reports for 2010 Portuguese companies in the non-finance sector. Findings indicate that performance does not explain impression management.Consistent with social psychology theory of impression management, larger companies present a favourable image of the firm, however consistent with ...

  5. Irreversibility and self-organization in spin glasses. 2. Irreversibility and the problem of configuration averaging

    International Nuclear Information System (INIS)

    Kovrov, V.P.; Kurbatov, A.M.

    1989-05-01

    The generalization of a configuration averaging to a system displaying irreversible effects is suggested. The properties of the ''pathological'' equilibrium state at low temperatures are determined and discussed. (author). 16 refs, 3 figs

  6. Handling of Polyvinylsiloxane Versus Polyether for Implant Impressions.

    Science.gov (United States)

    Farhan, Daniel; Lauer, Wiebke; Heydecke, Guido; Aarabi, Ghazal; Reissmann, Daniel R

    2016-01-01

    This study compared polyvinylsiloxane with polyether in handling dental impressions. Each participant (N = 39) made four impressions, each a combination of pickup and reseating techniques with polyether or polyvinylsiloxane, of one implant cast representing a specific clinical situation (tooth gaps, limited residual dentition, or edentulous jaw). Handling of impressions was subsequently rated by using a 12-item questionnaire with 100-mm visual analog scales. While mean satisfaction scores were higher for polyvinylsiloxane than for polyether (69.5/63.0, P < .001), differences among subgroups were statistically significant only for pickup technique, limited residual dentition, and edentulous jaw. Implant impressions made with polyvinylsiloxane using a pickup technique seem to be the best option for most clinical situations.

  7. Single Visit Feeding Appliance for 1-day-old Neonate with Cleft Palate Using Safe Dental Putty-Gauze Hybrid Impression Technique for Maxillary Impression

    OpenAIRE

    Rathee, Manu

    2015-01-01

    Cleft lip and palate is one of the most common craniofacial anomalies of humans. Intraoral impression making is the first clinical step in the fabrication of feeding appliance for infants with oro-nasal communication. It is difficult to control the flow of the impression material in the cleft area and undercuts in a child patient. This clinical report presents a simple and safe impression technique for maxillary impression making in neonates and infants with cleft palate. A gauze piece was us...

  8. Botulinum toxin a can positively impact first impression.

    Science.gov (United States)

    Dayan, Steven H; Lieberman, Elliot D; Thakkar, Nirav N; Larimer, Karen A; Anstead, Amy

    2008-06-01

    BACKGROUND First impression is influenced by facial appearance and improved by cosmetic surgery. OBJECTIVE We wanted to determine if treatment with botulinum toxin A (BTxnA) would improve first impression. MATERIALS AND METHODS Women received BTxnA in the forehead. Photos were taken prior to, and 1 week after, final BTxnA injection in smiling and relaxed poses. Photos were divided into books with each subject represented only once. Evaluators completed a survey rating first impression on various measures of success for each photo. RESULTS No differences were seen for social skills, financial, or relationship success scales. A significant decrease in first impression scores between treatment photos was seen for academic performance and occupational success. However, analysis of between-subject effects found that "smile/relax" accounted for the decreased score in both scales. Significant increases in first impression scores were seen for dating success, attractiveness, and athletic success scales where smile/relax and BTxnA contributed significantly to the improved scores. CONCLUSIONS BTxnA improved first impression scores for dating success, attractiveness, and athletic success scales. Academic performance and occupational success scores were not affected by BTxnA when the smile/relax variable was included. The smile/relax variable was a more important predictor for academic performance and occupational success scores.

  9. Sport fans' impressions of gay male athletes.

    Science.gov (United States)

    Campbell, Jamonn; Cothren, Denise; Rogers, Ross; Kistler, Lindsay; Osowski, Anne; Greenauer, Nathan; End, Christian

    2011-01-01

    The purpose of this study was to examine sport fans' impressions of gay male athletes. Participants formed impressions of a fictional athlete from their favorite team after reading a short scenario about the player. The scenarios described the athlete as being gay or straight, and either becoming a distraction or not causing a distraction to the team. While males' ratings of the athlete did not significantly differ, female fans formed significantly more positive impressions of the gay male player than the straight athlete. These results are discussed in terms of the ingroup bias and the shifting culture of homophobia in sport.

  10. Impression cytology diagnosis of ulcerative eyelid malignancy.

    Science.gov (United States)

    Sen, S; Lyngdoh, A D; Pushker, N; Meel, R; Bajaj, M S; Chawla, B

    2015-02-01

    The utility of impression cytology in ocular diseases has predominantly been restricted to the diagnosis of dry eye, limbal stem cell deficiency and conjunctival neoplasias. Its role in malignant eyelid lesions remains largely unexplored. Although scrape cytology is more popular for cutaneous lesions, impression cytology, being non-traumatic, has an advantage in small and delicate areas such as the eyelid. The present study has been designed to evaluate its role in the diagnosis and management of malignant eyelid lesions. Thirty-two histopathologically proven malignant eyelid lesions diagnosed over a 2-year period, including 13 basal cell carcinomas, 11 sebaceous carcinomas, four squamous cell carcinomas, two malignant melanomas and two poorly differentiated carcinomas, formed the study group. The results of impression cytology were compared with those of histopathology in the study group and with an age- and sex-matched group of benign cases as controls. The sensitivity of impression cytology was 84% (27/32) for the diagnosis of malignancy and 28% (9/32) for categorization of the type of malignancy. Impression cytology is a simple, useful, non-invasive technique for the detection of malignant ulcerative eyelid lesions. It is especially useful as a follow-up technique for the detection of recurrences. © 2014 John Wiley & Sons Ltd.

  11. Accuracy of Digital vs. Conventional Implant Impressions

    Science.gov (United States)

    Lee, Sang J.; Betensky, Rebecca A.; Gianneschi, Grace E.; Gallucci, German O.

    2015-01-01

    The accuracy of digital impressions greatly influences the clinical viability in implant restorations. The aim of this study is to compare the accuracy of gypsum models acquired from the conventional implant impression to digitally milled models created from direct digitalization by three-dimensional analysis. Thirty gypsum and 30 digitally milled models impressed directly from a reference model were prepared. The models were scanned by a laboratory scanner and 30 STL datasets from each group were imported to an inspection software. The datasets were aligned to the reference dataset by a repeated best fit algorithm and 10 specified contact locations of interest were measured in mean volumetric deviations. The areas were pooled by cusps, fossae, interproximal contacts, horizontal and vertical axes of implant position and angulation. The pooled areas were statistically analysed by comparing each group to the reference model to investigate the mean volumetric deviations accounting for accuracy and standard deviations for precision. Milled models from digital impressions had comparable accuracy to gypsum models from conventional impressions. However, differences in fossae and vertical displacement of the implant position from the gypsum and digitally milled models compared to the reference model, exhibited statistical significance (p<0.001, p=0.020 respectively). PMID:24720423

  12. Optimization at different loads by minimization of irreversibilities

    International Nuclear Information System (INIS)

    Wong, K.F.V.; Niu, Z.

    1991-01-01

    This paper reports that the irreversibility of the power cycle was chosen as the objective function as this function can successfully measure both the quality and quantity of energy flow in the cycle. Minimization of the irreversibility ensures that the power cycle will operate more efficiently. One feature of the present work is that the boiler, turbine, condenser and heaters are treated as one system for the purpose of optimization. In the optimization model, nine regression formulae are used, which are obtained from the measured test data. From the results of the present work, it can be seen that the optimization model developed can represent the effect of operational parameters on the power plant first and second law efficiency. Some of the results can be used to provide guidance for the optimal operation of the power plant. When the power cycle works at full load, the main steam temperature and pressure should be at the upper limit for minimal irreversibility of the system. If the load is less than 65% of its design capacity, the steam temperature and pressure should be decreased for a lower irreversibility of the system

  13. Complete Denture Impression Techniques Practiced by Private Dental Practitioners: A Survey

    OpenAIRE

    Kakatkar, Vinay R.

    2012-01-01

    Impression making is an important step in fabricating complete dentures. A survey to know the materials used and techniques practiced while recording complete denture impressions was conducted. It is disheartening to know that 33 % practitioners still use base plate custom trays to record final impressions. 8 % still use alginate for making final impressions. An acceptable technique for recording CD impressions is suggested.

  14. Dimensional Evaluation of Stone Die from Irreversíble Hydrocolloid Impression afther Disinfection Avaliação Dimensional de Troquéis de Gesso Obtidos de Moldes de Hidrocolóide Irreversível após Desinfecção

    Directory of Open Access Journals (Sweden)

    Marcos Frossard

    2004-10-01

    Full Text Available During routine molding procedures in Dentistry, the material gets in touch with oral fluids such as blood, saliva, exudates and others, which can carry pathogenic microorganisms that cause contagious diseases such us herpes, hepatitis, tuberculosis, AIDS, among others. Disinfection by immersing the molds in chemical solutions has been adopted. This work evaluated dimensional alterations in casts obtained from an irreversible hydrocolloid, after disinfection. A molding device with a standard metallic die representing the tooth ready to receive the crown was used during the evaluation. The molds were then immersed in deionized water and gluteraldehyde at 2% for 30 minutes. Only the control group was not immersed: they were poured in a special type IV (Durone, immediately after being taken. A special standard metallic crown, which adapted itself to the referred casts, was used to evaluate their dimensions. The combination die plus standard crown was submitted to a microscopic analysis by a depth microscope. Data from the evaluation were submitted to a statistical analysis, and the results showed no statistically difference among the groups studied. Nos procedimentos de moldagens, rotineiramente executados em Odontologia, os materiais entram em contacto com fluidos bucais, como: sangue, saliva, exudatos e outros que podem conter microorganismos patogênicos e, pelos moldes, podem transmitir doenças infecto-contagiosas como: herpes, hepatite, tuberculose, AIDS, dentre outras. O tratamento por imersão desses moldes em substâncias químicas, tem sido adotado no sentido de promover a desinfecção dos mesmos. Este trabalho avaliou a alteração dimensional de troquéis de gesso obtidos de moldes de hidrocolóide irreversível (alginato, após desinfecção. Utilizou-se, para isso, um dispositivo de moldagem que contém um troquel-padrão metálico, representando um dente preparado para receber uma coroa. Após a obtenção dos moldes, os mesmos foram

  15. A Randomised Controlled Trial of complete denture impression materials

    Science.gov (United States)

    Hyde, T.P.; Craddock, H.L.; Gray, J.C.; Pavitt, S.H.; Hulme, C.; Godfrey, M.; Fernandez, C.; Navarro-Coy, N.; Dillon, S.; Wright, J.; Brown, S.; Dukanovic, G.; Brunton, P.A.

    2014-01-01

    Objectives There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Methods Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Results Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7–67.3%, p alginate as their material of choice for secondary impressions for complete dentures. Trial Registration: ISRCTN 01528038.

 This article forms part of a project for which the author (TPH) won the Senior Clinical Unilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. PMID:24995473

  16. Cost comparison of pressure ulcer preventive dressings: hydrocolloid dressing versus transparent polyurethane film.

    Science.gov (United States)

    Dutra, R A A; Salomé, G M; Leal, L M F; Alves, M G; Moura, J P; Silva, A T; Pereira, V O S; de Brito, M J A; Ferreira, L M

    2016-11-02

    To evaluate and compare the costs of using a transparent polyurethane film (PF) and hydrocolloid dressing (HD) in the prevention of pressure ulcers (PUs). This descriptive, observational, longitudinal, comparative study was conducted in the intensive care units, coronary care unit and medical clinic of a charity hospital in Brazil. Data were collected during a 30-day study period, consisting of physical examination, assessment of risk factors for PU development and application of the Braden scale, which were performed at inclusion in the study and once daily during hospitalisation. Either PF or HD was applied bilaterally in the sacral and trochanteric regions for prevention of PUs in patients at a moderate to high risk of PUs according to the Braden scale, and costs of using PU preventive dressings were estimated. The mean total costs per dressing change per patient when using the HD and PF to prevent PUs were 413.60 BRL and 74.04 BRL, respectively. There were significant between-group differences in mean costs for all variables, except for saline solution and nurse-technician services. Results showed that the mean cost per dressing change per patient was lower when using the transparent PF than when using the HD.

  17. Valuing Women in Management: An Impression Management Perspective of Gender Diversity.

    Science.gov (United States)

    Gardner, William L., III; And Others

    1994-01-01

    Applies a model of impression management to explore the process whereby women in organizations present themselves to others and the impressions they create. Devotes particular attention to how these impressions influence women's experiences in organizations. Suggests future research direction for clarifying the impact of gender impression and…

  18. Accuracy of stone casts obtained by different impression materials

    Directory of Open Access Journals (Sweden)

    Adriana Cláudia Lapria Faria

    2008-12-01

    Full Text Available Several impression materials are available in the Brazilian marketplace to be used in oral rehabilitation. The aim of this study was to compare the accuracy of different impression materials used for fixed partial dentures following the manufacturers' instructions. A master model representing a partially edentulous mandibular right hemi-arch segment whose teeth were prepared to receive full crowns was used. Custom trays were prepared with auto-polymerizing acrylic resin and impressions were performed with a dental surveyor, standardizing the path of insertion and removal of the tray. Alginate and elastomeric materials were used and stone casts were obtained after the impressions. For the silicones, impression techniques were also compared. To determine the impression materials' accuracy, digital photographs of the master model and of the stone casts were taken and the discrepancies between them were measured. The data were subjected to analysis of variance and Duncan's complementary test. Polyether and addition silicone following the single-phase technique were statistically different from alginate, condensation silicone and addition silicone following the double-mix technique (p .05 to alginate and addition silicone following the double-mix technique, but different from polysulfide. The results led to the conclusion that different impression materials and techniques influenced the stone casts' accuracy in a way that polyether, polysulfide and addition silicone following the single-phase technique were more accurate than the other materials.

  19. A randomised controlled trial of complete denture impression materials.

    Science.gov (United States)

    Hyde, T P; Craddock, H L; Gray, J C; Pavitt, S H; Hulme, C; Godfrey, M; Fernandez, C; Navarro-Coy, N; Dillon, S; Wright, J; Brown, S; Dukanovic, G; Brunton, P A

    2014-08-01

    There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7-67.3%, pUnilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Custom sectional impression trays with interlocking type handle for microstomia patients

    Directory of Open Access Journals (Sweden)

    Fernandes Aquaviva

    2009-01-01

    Full Text Available Making impressions in microstomia patients is often cumbersome. A modification of standard impression procedure is often necessary while treating such patients. This article describes the fabrication of a custom sectional impression tray with interlocking type of a handle for definitive impression procedures in a microstomia patient.

  1. Accuracy of 3 different impression techniques for internal connection angulated implants.

    Science.gov (United States)

    Tsagkalidis, George; Tortopidis, Dimitrios; Mpikos, Pavlos; Kaisarlis, George; Koidis, Petros

    2015-10-01

    Making implant impressions with different angulations requires a more precise and time-consuming impression technique. The purpose of this in vitro study was to compare the accuracy of nonsplinted, splinted, and snap-fit impression techniques of internal connection implants with different angulations. An experimental device was used to allow a clinical simulation of impression making by means of open and closed tray techniques. Three different impression techniques (nonsplinted, acrylic-resin splinted, and indirect snap-fit) for 6 internal-connected implants at different angulations (0, 15, 25 degrees) were examined using polyether. Impression accuracy was evaluated by measuring the differences in 3-dimensional (3D) position deviations between the implant body/impression coping before the impression procedure and the coping/laboratory analog positioned within the impression, using a coordinate measuring machine. Data were analyzed by 2-way ANOVA. Means were compared with the least significant difference criterion at Pimpression technique exhibited a higher accuracy than the other techniques studied when increased implant angulations at 25 degrees were involved. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. 17 CFR 200.61 - Impressions of influence.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 2 2010-04-01 2010-04-01 false Impressions of influence. 200...; CONDUCT AND ETHICS; AND INFORMATION AND REQUESTS Canons of Ethics § 200.61 Impressions of influence. A... influence him, that any person unduly enjoys his favor or that he is affected in any way by the rank...

  3. An evaluation of student and clinician perception of digital and conventional implant impressions.

    Science.gov (United States)

    Lee, Sang J; Macarthur, Robert X; Gallucci, German O

    2013-11-01

    The accuracy and efficiency of digital implant impressions should match conventional impressions. Comparisons should be made with clinically relevant data. The purpose of this study was to evaluate the difficulty level and operator's perception between dental students and experienced clinicians when making digital and conventional implant impressions. Thirty experienced dental professionals and 30 second-year dental students made conventional and digital impressions of a single implant model. A visual analog scale (VAS) and multiple-choice questionnaires were used to assess the participant's perception of difficulty, preference, and effectiveness. Wilcoxon signed-rank test within the groups and Wilcoxon rank-sum test between the groups were used for statistical analysis (α=.05). On a 0 to 100 VAS, the student group scored a mean difficulty level of 43.1 (±18.5) for the conventional impression technique and 30.6 (±17.6) for the digital impression technique (P=.006). The clinician group scored a mean (standard deviation) difficulty level of 30.9 (±19.6) for conventional impressions and 36.5 (±20.6) for digital impressions (P=.280). Comparison between groups showed a mean difficulty level with the conventional impression technique significantly higher in the student group (P=.030). The digital impression was not significantly different between the groups (P=.228). Sixty percent of the students preferred the digital impression and 7% the conventional impression; 33% expressed no preference. In the clinician group, 33% preferred the digital impression and 37% the conventional impression; 30% had no preference. Seventy-seven percent of the student group felt most effective with digital impressions, 10% with conventional impressions, and 13% with either technique, whereas 40% of the clinician group chose the digital impression as the most effective technique, 53% the conventional impression, and 7% either technique. The conventional impression was more difficult to

  4. Conventional Vs Digital Impressions: Acceptability, Treatment Comfort and Stress Among Young Orthodontic Patients.

    Science.gov (United States)

    Mangano, Alessandro; Beretta, Matteo; Luongo, Giuseppe; Mangano, Carlo; Mangano, Francesco

    2018-01-01

    The objective of the present study was to compare patients' acceptability, comfort and stress with conventional and digital impressions. Thirty young orthodontic patients (15 males and 15 females) who had no previous experience of impressions were enrolled in this study. Conventional impressions for orthodontic study models of the dental arches were taken using an alginate impression material (Hydrogum ® , Zhermack Spa, Badia Polesine, Rovigo, Italy). Fifteen days later, digital impressions of both arches were acquired using an intraoral scanner (CS3600 ® , Carestream Dental, Rochester, NY, USA). Immediately after impression taking, patients' acceptability, comfort and stress were measured using two questionnaires and the State anxiety scale. Data showed no difference in terms of anxiety and stress; however, patients preferred the use of digital impressions systems instead of conventional impression techniques. Alginate impressions resulted as fast as digital impressions. Digital impressions resulted the most accepted and comfortable impression technique in young orthodontic patients, when compared to conventional techniques.

  5. Conventional Vs Digital Impressions: Acceptability, Treatment Comfort and Stress Among Young Orthodontic Patients

    Science.gov (United States)

    Mangano, Alessandro; Beretta, Matteo; Luongo, Giuseppe; Mangano, Carlo; Mangano, Francesco

    2018-01-01

    Objective: The objective of the present study was to compare patients’ acceptability, comfort and stress with conventional and digital impressions. Materials and Methods: Thirty young orthodontic patients (15 males and 15 females) who had no previous experience of impressions were enrolled in this study. Conventional impressions for orthodontic study models of the dental arches were taken using an alginate impression material (Hydrogum®, Zhermack Spa, Badia Polesine, Rovigo, Italy). Fifteen days later, digital impressions of both arches were acquired using an intraoral scanner (CS3600®, Carestream Dental, Rochester, NY, USA). Immediately after impression taking, patients’ acceptability, comfort and stress were measured using two questionnaires and the State anxiety scale. Results: Data showed no difference in terms of anxiety and stress; however, patients preferred the use of digital impressions systems instead of conventional impression techniques. Alginate impressions resulted as fast as digital impressions. Conclusions: Digital impressions resulted the most accepted and comfortable impression technique in young orthodontic patients, when compared to conventional techniques. PMID:29492177

  6. Substance P and CGRP expression in dental pulps with irreversible pulpitis.

    Science.gov (United States)

    Sattari, Mandana; Mozayeni, Mohammad Ali; Matloob, Arash; Mozayeni, Maryam; Javaheri, Homan H

    2010-08-01

    The purpose of this study was to compare substance P (SP) and calcitonin gene-related peptide (CGRP) expression in pulp tissue with clinically diagnosed symptomatic and asymptomatic irreversible pulpitis. Healthy pulps acted as controls. Five normal pulps and 40 with irreversible pulpitis (20 symptomatic and 20 asymptomatic) were obtained from 45 different patients. SP and CGRP expression was determined by competition binding assays using enzyme immunoassay. anova and Mann-Whitney tests were used to ascertain if there were statistically significant differences between the groups. The results showed that neuropeptides were found in all pulp samples. The highest and the lowest expressions for SP and CGRP were found in symptomatic irreversible pulpitis and healthy pulps groups, respectively. The differences between healthy pulps and the groups of pulps having irreversible pulpitis were significant (P pulpitis groups (P pulpitis groups were not significant. This study demonstrated that the expression of CGRP and SP is significantly higher in pulps with irreversible pulpitis compared with healthy pulps.

  7. Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.

    Science.gov (United States)

    Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G

    2017-07-01

    Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P 90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.

  8. Inherent variation in multiple shoe-sole test impressions.

    Science.gov (United States)

    Shor, Yaron; Wiesner, Sarena; Tsach, Tsadok; Gurel, Ron; Yekutieli, Yoram

    2018-04-01

    Shoeprints left at crime scenes are seldom perfect. Many prints are distorted or contaminated by various materials. Noisy background often contributes to vagueness on the shoeprints as well. Test impressions made from the suspect's shoes in the laboratory are considered a genuine replication of the shoe-sole. This naïve attitude is far from being correct. Consecutive test impressions made in the laboratory under strict similar conditions revealed differences among the exemplars of the same sole. Some of them are minor, but some are major, and can mislead the less experienced practitioners during the comparison process. This article focuses on the inherent within source variability between controlled shoeprints made from the same shoe, as it appears on the RACs. To describe and analyze this variability, repeated test impressions were prepared, and datasets were created. Several RACs were marked on each test impression, using an expert assisting software tool (developed in the authors' lab). The variance in repeated test impressions is demonstrated and possible sources are discussed. This variance should be considered when trying to establish the degree of matching between individual characteristics. Copyright © 2017. Published by Elsevier B.V.

  9. Electronic evaluation for video commercials by impression index.

    Science.gov (United States)

    Kong, Wanzeng; Zhao, Xinxin; Hu, Sanqing; Vecchiato, Giovanni; Babiloni, Fabio

    2013-12-01

    How to evaluate the effect of commercials is significantly important in neuromarketing. In this paper, we proposed an electronic way to evaluate the influence of video commercials on consumers by impression index. The impression index combines both the memorization and attention index during consumers observing video commercials by tracking the EEG activity. It extracts features from scalp EEG to evaluate the effectiveness of video commercials in terms of time-frequency-space domain. And, the general global field power was used as an impression index for evaluation of video commercial scenes as time series. Results of experiment demonstrate that the proposed approach is able to track variations of the cerebral activity related to cognitive task such as observing video commercials, and help to judge whether the scene in video commercials is impressive or not by EEG signals.

  10. Guinea pig ductus arteriosus. II - Irreversible closure after birth.

    Science.gov (United States)

    Fay, F. S.; Cooke, P. H.

    1972-01-01

    To investigate the mechanism underlying irreversibility of ductal closure after birth, studies were undertaken to determine the exact time course for the onset of irreversible closure of the guinea pig ductus arteriosus. Parallel studies of the reactivity of ductal smooth muscle to oxygen and studies of the postpartum cellular changes within the vessel were also carried out.

  11. Accuracy of a self-perforating impression tray for dental implants.

    Science.gov (United States)

    Marotti, Juliana; Tortamano, Pedro; Castilho, Tatiana R R N; Steagall, Washington; Wolfart, Stefan; Haselhuhn, Klaus

    2014-10-01

    Difficulties are involved in impression making with conventional open impression trays. The purpose of this study was to evaluate the accuracy of transferring implant impressions with a self-perforating impression tray. A reference model of a mandible was fabricated, and 4 implants were placed in the regions of the first premolars and lateral incisors (implants 1, 2, 3, 4). Ten impressions of the reference model with polyvinyl siloxane were made for each group; control (conventional open impression tray) and test (self-perforating impression tray; Miratray Implant). A metal bar was screw-retained on implant 1, and the gaps generated at the vestibular face of implants 3 and 4 were measured by optical microcopy. The 2-way ANOVA and least square difference post hoc test were used (α=.05). Higher mean (±SD) values were obtained for the test group than for the control group for both implants: implant 3: 150 ±84 μm for the test group, 73 ±63 μm for the control group (P=.019); implant 4: 129 ±65 μm for the test group, 62 ±61 μm for the control group (P=.04). The self-perforating impression tray provided less accuracy than the conventional open tray. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Multiscale time irreversibility of heart rate and blood pressure variability during orthostasis

    International Nuclear Information System (INIS)

    Chladekova, L; Czippelova, B; Turianikova, Z; Tonhajzerova, I; Calkovska, A; Javorka, M; Baumert, M

    2012-01-01

    Time irreversibility is a characteristic feature of non-equilibrium, complex systems such as the cardiovascular control mediated by the autonomic nervous system (ANS). Time irreversibility analysis of heart rate variability (HRV) and blood pressure variability (BPV) represents a new approach to assess cardiovascular regulatory mechanisms. The aim of this paper was to assess the changes in HRV and BPV irreversibility during the active orthostatic test (a balance of ANS shifted towards sympathetic predominance) in 28 healthy young subjects. We used three different time irreversibility indices—Porta’s, Guzik's and Ehler's indices (P%, G% and E, respectively) derived from data segments containing 1000 beat-to-beat intervals on four timescales. We observed an increase in the HRV and a decrease in the BPV irreversibility during standing compared to the supine position. The postural change in irreversibility was confirmed by surrogate data analysis. The differences were more evident in G% and E than P% and for higher scale factors. Statistical analysis showed a close relationship between G% and E. Contrary to this, the association between P% and G% and P% and E was not proven. We conclude that time irreversibility of beat-to-beat HRV and BPV is significantly altered during orthostasis, implicating involvement of the autonomous nervous system in its generation. (paper)

  13. In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.

    Science.gov (United States)

    Ender, Andreas; Zimmermann, Moritz; Attin, Thomas; Mehl, Albert

    2016-09-01

    Quadrant impressions are commonly used as alternative to full-arch impressions. Digital impression systems provide the ability to take these impressions very quickly; however, few studies have investigated the accuracy of the technique in vivo. The aim of this study is to assess the precision of digital quadrant impressions in vivo in comparison to conventional impression techniques. Impressions were obtained via two conventional (metal full-arch tray, CI, and triple tray, T-Tray) and seven digital impression systems (Lava True Definition Scanner, T-Def; Lava Chairside Oral Scanner, COS; Cadent iTero, ITE; 3Shape Trios, TRI; 3Shape Trios Color, TRC; CEREC Bluecam, Software 4.0, BC4.0; CEREC Bluecam, Software 4.2, BC4.2; and CEREC Omnicam, OC). Impressions were taken three times for each of five subjects (n = 15). The impressions were then superimposed within the test groups. Differences from model surfaces were measured using a normal surface distance method. Precision was calculated using the Perc90_10 value. The values for all test groups were statistically compared. The precision ranged from 18.8 (CI) to 58.5 μm (T-Tray), with the highest precision in the CI, T-Def, BC4.0, TRC, and TRI groups. The deviation pattern varied distinctly depending on the impression method. Impression systems with single-shot capture exhibited greater deviations at the tooth surface whereas high-frame rate impression systems differed more in gingival areas. Triple tray impressions displayed higher local deviation at the occlusal contact areas of upper and lower jaw. Digital quadrant impression methods achieve a level of precision, comparable to conventional impression techniques. However, there are significant differences in terms of absolute values and deviation pattern. With all tested digital impression systems, time efficient capturing of quadrant impressions is possible. The clinical precision of digital quadrant impression models is sufficient to cover a broad variety of

  14. Irreversibility and conditional probability

    International Nuclear Information System (INIS)

    Stuart, C.I.J.M.

    1989-01-01

    The mathematical entropy - unlike physical entropy - is simply a measure of uniformity for probability distributions in general. So understood, conditional entropies have the same logical structure as conditional probabilities. If, as is sometimes supposed, conditional probabilities are time-reversible, then so are conditional entropies and, paradoxically, both then share this symmetry with physical equations of motion. The paradox is, of course that probabilities yield a direction to time both in statistical mechanics and quantum mechanics, while the equations of motion do not. The supposed time-reversibility of both conditionals seems also to involve a form of retrocausality that is related to, but possibly not the same as, that described by Costa de Beaurgard. The retrocausality is paradoxically at odds with the generally presumed irreversibility of the quantum mechanical measurement process. Further paradox emerges if the supposed time-reversibility of the conditionals is linked with the idea that the thermodynamic entropy is the same thing as 'missing information' since this confounds the thermodynamic and mathematical entropies. However, it is shown that irreversibility is a formal consequence of conditional entropies and, hence, of conditional probabilities also. 8 refs. (Author)

  15. Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

    Science.gov (United States)

    Rhee, Ye-Kyu; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin

    2015-12-01

    The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (Pimpression and the smallest difference was seen between dual-arch and full-arch impression. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P.05).

  16. In vivo precision of conventional and digital methods for obtaining quadrant dental impressions

    OpenAIRE

    Ender, Andreas; Zimmermann, Moritz; Attin, Thomas; Mehl, Albert

    2016-01-01

    OBJECTIVES Quadrant impressions are commonly used as alternative to full-arch impressions. Digital impression systems provide the ability to take these impressions very quickly; however, few studies have investigated the accuracy of the technique in vivo. The aim of this study is to assess the precision of digital quadrant impressions in vivo in comparison to conventional impression techniques. MATERIALS AND METHODS Impressions were obtained via two conventional (metal full-arch tray, CI, ...

  17. Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept.

    Science.gov (United States)

    Liu, David Yu; Cader, Fathima Nashmie; Abduo, Jaafar; Palamara, Joseph

    2017-12-29

    To evaluate implant impression accuracy with a new tray design concept in comparison to nonsplinted and splinted impression techniques for a 2-implant situation. A reference bar titanium framework was fabricated to fit on 2 parallel implants. The framework was used to generate a resin master model with 2 implants that fit precisely against the framework. Three impression techniques were evaluated: (1) nonsplinted, (2) splinted, and (3) nonsplinted with modified tray impressions. All the trays were fabricated from light-cured acrylic resin material with openings that corresponded to the implant impression copings. Ten impressions were taken for each technique using poly(vinyl siloxane) impression material. The impressions were poured with type IV dental stone to generate the test casts. A rosette strain gauge was bonded to the middle of the framework. As the framework retaining screws were tightened on each test cast, the developed strains were recorded until the completion of the tightening to 35 Ncm. The generated strains of the rosette strain gauge were used to calculate the maximum principal strain. A statistically significant difference was observed among the different impression techniques. The modified tray design impression technique was associated with the least framework strains, which indicates greater accuracy compared with the other techniques. There was no significant difference between the splinted and the nonsplinted impression techniques. The new tray design concept appeared to produce more accurate implant impressions than the other techniques. Despite the statistical difference among the impression techniques, the clinical significance of this difference is yet to be determined. © 2017 by the American College of Prosthodontists.

  18. [Impression Formation in the Diagnosis and Treatment of Mental Disorders].

    Science.gov (United States)

    Linden, Michael; Dymke, Tina; Hüttner, Susanne; Schnaubelt, Sabine

    2016-06-01

    The first item of any psychopathological assessment is "general impression". There is some research under the heading of "impression formation" which shows that the outer appearance of a person decides about how a person is perceived by others and how others react. Impression formation is an important factor in social interaction. This is of special importance in mental disorders, which may express themselves in a distorted impression formation. As impression formation is by and large an emotional process, measurement can be done by adjective lists. An example is the bipolar MED rating scale. Such lists can be used in therapy to help patients and therapists to understand the problem and initiate modifications. A special group intervention in occupational therapy is described. Results suggest that impression formation is quite objective, that self- and observer judgments coincide and that therapy can help to adopt a less irritating outer appearance. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Performance Optimization of Irreversible Air Heat Pumps Considering Size Effect

    Science.gov (United States)

    Bi, Yuehong; Chen, Lingen; Ding, Zemin; Sun, Fengrui

    2018-06-01

    Considering the size of an irreversible air heat pump (AHP), heating load density (HLD) is taken as thermodynamic optimization objective by using finite-time thermodynamics. Based on an irreversible AHP with infinite reservoir thermal-capacitance rate model, the expression of HLD of AHP is put forward. The HLD optimization processes are studied analytically and numerically, which consist of two aspects: (1) to choose pressure ratio; (2) to distribute heat-exchanger inventory. Heat reservoir temperatures, heat transfer performance of heat exchangers as well as irreversibility during compression and expansion processes are important factors influencing on the performance of an irreversible AHP, which are characterized with temperature ratio, heat exchanger inventory as well as isentropic efficiencies, respectively. Those impacts of parameters on the maximum HLD are thoroughly studied. The research results show that HLD optimization can make the size of the AHP system smaller and improve the compactness of system.

  20. Kinetic theory of nonequilibrium ensembles, irreversible thermodynamics, and generalized hydrodynamics

    CERN Document Server

    Eu, Byung Chan

    2016-01-01

    This book presents the fundamentals of irreversible thermodynamics for nonlinear transport processes in gases and liquids, as well as for generalized hydrodynamics extending the classical hydrodynamics of Navier, Stokes, Fourier, and Fick. Together with its companion volume on relativistic theories, it provides a comprehensive picture of the kinetic theory formulated from the viewpoint of nonequilibrium ensembles in both nonrelativistic and, in Vol. 2, relativistic contexts. Theories of macroscopic irreversible processes must strictly conform to the thermodynamic laws at every step and in all approximations that enter their derivation from the mechanical principles. Upholding this as the inviolable tenet, the author develops theories of irreversible transport processes in fluids (gases or liquids) on the basis of irreversible kinetic equations satisfying the H theorem. They apply regardless of whether the processes are near to or far removed from equilibrium, or whether they are linear or nonlinear with respe...

  1. Virtual First Impressions

    Science.gov (United States)

    Bergren, Martha Dewey

    2005-01-01

    Frequently, a nurse's first and only contact with a graduate school, legislator, public health official, professional organization, or school nursing colleague is made through e-mail. The format, the content, and the appearance of the e-mail create a virtual first impression. Nurses can manage their image and the image of the profession by…

  2. The quality of impressions for crowns and bridges: an assessment of the work received at three commercial dental laboratories. assessing the quality of the impressions of prepared teeth.

    Science.gov (United States)

    Storey, D; Coward, T J

    2013-06-01

    The literature is limited in studies directly assessing the quality of impressions for crowns and bridges in the UK. The aim of the study was to assess the quality of impressions for conventional crown and bridgework received by commercial dental laboratories. Three dental laboratories were visited over a 3-month period. All impressions for conventional crowns and bridges that arrived on the days of the visits were examined prior to any laboratory processing. A total of 206 impression cases were examined and assessed against criteria laid out in a custom-designed assessment form. Defects were commonly found in the recording of prepared teeth. Overall, 44.2% of impression cases were unsatisfactory. NHS impressions were more than twice as likely to be unsatisfactory compared to private impressions. If the results of this survey are typical then the general quality of impressions for fixed crown and bridgework is unacceptable. This is particularly true for work completed under the NHS contract.

  3. Transition to Clean Capital, Irreversible Investment and Stranded Assets

    OpenAIRE

    Rozenberg, Julie; Vogt-Schilb, Adrien; Hallegatte, Stephane

    2014-01-01

    This paper uses a Ramsey model with two types of capital to analyze the optimal transition to clean capital when polluting investment is irreversible. The cost of climate mitigation decomposes as a technical cost of using clean instead of polluting capital and a transition cost from the irreversibility of pre-existing polluting capital. With a carbon price, the transition cost can be limit...

  4. Spectral line intensity irreversibility in circulatory plasma magnetization processes

    Science.gov (United States)

    Qu, Z. Q.; Dun, G. T.

    2012-01-01

    Spectral line intensity variation is found to be irreversible in circulatory plasma magnetization process by experiments described in this paper, i.e., the curves illustrating spectral line photon fluxes irradiated from a light source immerged in a magnetic field by increasing the magnetic induction cannot be reproduced by decreasing the magnetic induction within the errors. There are two plasma magnetization patterns found. One shows that the intensities are greater at the same magnetic inductions during the magnetic induction decreasing process after the increasing, and the other gives the opposite effect. This reveals that the magneto-induced excitation and de-excitation process is irreversible like ferromagnetic magnetization. But the two irreversible processes are very different in many aspects stated in the text.

  5. IMPRESS Integrated Project-An overview paper

    International Nuclear Information System (INIS)

    Jarvis, D.J.; Voss, D.

    2005-01-01

    IMPRESS is an acronym for Intermetallic Materials Processing in Relation to Earth and Space Solidification. This project was selected by the European Commission and recently started in November 2004. The main scientific objective of IMPRESS is to gain a better understanding of the links between materials processing routes, structure and final properties of intermetallic alloys. Technically speaking, the project aims to develop and test two distinct prototypes based on intermetallic materials, namely gas turbine blades and Raney-type catalytic powder. Numerous material processing routes are being explored within the project with a strong emphasis on solidification. For turbine blade manufacturing, the principal processes under study are tilt casting, counter-gravity casting and centrifugal casting. For catalytic powder production, the focus is placed on gas atomisation and vapour condensation processes. IMPRESS combines a wide range of fundamental studies of solidification both on ground and in space, as well as industrial process development. This paper will describe some of the different facets related to solidification

  6. Accuracy of five implant impression technique: effect of splinting materials and methods

    Science.gov (United States)

    Cho, Sung-Bum

    2011-01-01

    PURPOSE The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z-axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (Pimpression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure. PMID:22259700

  7. Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

    Science.gov (United States)

    Rhee, Ye-Kyu

    2015-01-01

    PURPOSE The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (Pimpression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P.05). PMID:26816576

  8. Digital vs. conventional full-arch implant impressions: a comparative study.

    Science.gov (United States)

    Amin, Sarah; Weber, Hans Peter; Finkelman, Matthew; El Rafie, Khaled; Kudara, Yukio; Papaspyridakos, Panos

    2017-11-01

    To test whether or not digital full-arch implant impressions with two different intra-oral scanners (CEREC Omnicam and True Definition) have the same accuracy as conventional ones. The hypothesis was that the splinted open-tray impressions would be more accurate than digital full-arch impressions. A stone master cast representing an edentulous mandible using five internal connection implant analogs (Straumann Bone Level RC, Basel, Switzerland) was fabricated. The three median implants were parallel to each other, the far left implant had 10°, and the far right had 15° distal angulation. A splinted open-tray technique was used for the conventional polyether impressions (n = 10) for Group 1. Digital impressions (n = 10) were taken with two intra-oral optical scanners (CEREC Omnicam and 3M True Definition) after connecting polymer scan bodies to the master cast for groups 2 and 3. Master cast and conventional impression test casts were digitized with a high-resolution reference scanner (Activity 880 scanner; Smart Optics, Bochum, Germany) to obtain digital files. Standard tessellation language (STL) datasets from the three test groups of digital and conventional impressions were superimposed with the STL dataset from the master cast to assess the 3D deviations. Deviations were recorded as root-mean-square error. To compare the master cast with conventional and digital impressions at the implant level, Welch's F-test was used together with Games-Howell post hoc test. Group I had a mean value of 167.93 μm (SD 50.37); Group II (Omnicam) had a mean value of 46.41 μm (SD 7.34); Group III (True Definition) had a mean value of 19.32 μm (SD 2.77). Welch's F-test was used together with the Games-Howell test for post hoc comparisons. Welch's F-test showed a significant difference between the groups (P digital implant impressions using True Definition scanner and Omnicam were significantly more accurate than the conventional impressions with the splinted open

  9. Ecological optimization and parametric study of irreversible Stirling and Ericsson heat pumps

    International Nuclear Information System (INIS)

    Tyagi, S.K.; Kaushik, S.C.; Salohtra, R.

    2002-01-01

    This communication presents the ecological optimization and parametric study of irreversible Stirling and Ericsson heat pump cycles, in which the external irreversibility is due to finite temperature difference between working fluid and external reservoirs while the internal irreversibilities are due to regenerative heat loss and other entropy generations within the cycle. The ecological function is defined as the heating load minus the irreversibility (power loss) which is ambient temperature times the entropy generation. The ecological function is optimized with respect to working fluid temperatures, and the expressions for various parameters at the optimal operating condition are obtained. The effects of different operating parameters on the performance of these cycles have been studied. It is found that the effect of internal irreversibility parameter is more pronounced than the other parameters on the performance of these cycles. (author)

  10. Ictal time-irreversible intracranial EEG signals as markers of the epileptogenic zone.

    Science.gov (United States)

    Schindler, Kaspar; Rummel, Christian; Andrzejak, Ralph G; Goodfellow, Marc; Zubler, Frédéric; Abela, Eugenio; Wiest, Roland; Pollo, Claudio; Steimer, Andreas; Gast, Heidemarie

    2016-09-01

    To show that time-irreversible EEG signals recorded with intracranial electrodes during seizures can serve as markers of the epileptogenic zone. We use the recently developed method of mapping time series into directed horizontal graphs (dHVG). Each node of the dHVG represents a time point in the original intracranial EEG (iEEG) signal. Statistically significant differences between the distributions of the nodes' number of input and output connections are used to detect time-irreversible iEEG signals. In 31 of 32 seizure recordings we found time-irreversible iEEG signals. The maximally time-irreversible signals always occurred during seizures, with highest probability in the middle of the first seizure half. These signals spanned a large range of frequencies and amplitudes but were all characterized by saw-tooth like shaped components. Brain regions removed from patients who became post-surgically seizure-free generated significantly larger time-irreversibilities than regions removed from patients who still had seizures after surgery. Our results corroborate that ictal time-irreversible iEEG signals can indeed serve as markers of the epileptogenic zone and can be efficiently detected and quantified in a time-resolved manner by dHVG based methods. Ictal time-irreversible EEG signals can help to improve pre-surgical evaluation in patients suffering from pharmaco-resistant epilepsies. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Irreversible properties of YBCO coated conductors

    International Nuclear Information System (INIS)

    Vostner, A.

    2001-02-01

    Over the past few years substantial efforts were made to optimize the fabrication techniques of various high temperature superconductors for commercial applications. In addition to Bi-2223 tapes, Y-123 coated conductors have the potential for large-scale production and are considered as the second generation of superconducting 'wires' for high current applications. This work reports on magnetic and transport current investigations of Y-123 thick films deposited on either single crystalline substrates by liquid phase epitaxy (LPE) or on metallic substrates by pulsed laser deposition (PLD). At the beginning, a short introduction of the general idea of a coated conductor and of the different production techniques is presented, followed by a description of the different experimental set-ups and the evaluation methods. The main part starts with the results obtained from SQUID magnetometry and ac-susceptibility measurements including the transition temperatures T c , the field dependence of the magnetic critical current densities and the irreversibility lines. In addition, some issues concerning the granular structure and the inter- and intragranular current distribution of the superconducting films are discussed. The investigations by transport currents are focused on the behavior of the application relevant irreversible parameters. These are the angular and the field dependence of the critical transport current densities at 77 and 60 K, as well as the temperature dependence of the irreversibility fields up to 6 T. To gain more insight into the defect structure of the films, neutron irradiation studies were performed on some samples. The introduction of these artificial pinning centers causes large enhancements of the magnetic J c in LPE specimens for the field parallel to the c-axis (H//c) at higher temperatures and magnetic fields. The granular structure of the samples does not change up to the highest neutron fluences. However, the enhancements of the transport J c

  12. Irreversibility analysis in the process of solar distillation

    International Nuclear Information System (INIS)

    Chávez, S; Terres, H; Lizardi, A; López, R; Lara, A

    2017-01-01

    In this work an irreversibility analysis for the thermal process of solar distillation of three different substances is presented, for which it employs a solar still of a slope where three experimental tests with 5.5 L of brine, river water and MgCl 2 were performed. Temperature data principally in the glass cover, absorber plate, fluid, environment and the incident solar radiation on the device were obtained. With measurements of temperature, solar radiation and exergetic balance, irreversibilities are found on the device. The results show that the highest values of irreversibilities are concentrated in the absorber plate with an average of 321 W, 342 W and 276 W, followed by the cover glass with an average of 75.8 W, 80.4 W and 86.7 W and finally the fluid with 15.3 W, 15.9 W and 16 W, for 5.5 L of brine, river water and MgCl 2 . (paper)

  13. Performance of an irreversible quantum Ericsson cooler at low temperature limit

    International Nuclear Information System (INIS)

    Wu Feng; Chen Lingen; Wu Shuang; Sun Fengrui

    2006-01-01

    The purpose of this paper is to investigate the effect of quantum properties of the working medium on the performance of an irreversible quantum Ericsson cooler with spin-1/2. The cooler is studied with the losses of heat resistance, heat leakage and internal irreversibility. The optimal relationship between the dimensionless cooling load R * versus the coefficient of performance ε for the irreversible quantum Ericsson cooler is derived. In particular, the performance characteristics of the cooler at the low temperature limit are discussed

  14. Dental impression technique using optoelectronic devices

    Science.gov (United States)

    Sinescu, Cosmin; Barua, Souman; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Duma, Virgil-Florin; Gabor, Alin Gabriel; Zaharia, Cristian; Bradu, Adrian; Podoleanu, Adrian G.

    2018-03-01

    INTRODUCTION: The use of Optical Coherence Tomography (OCT) as a non-invasive and high precision quantitative information providing tool has been well established by researches within the last decade. The marginal discrepancy values can be scrutinized in optical biopsy made in three dimensional (3D) micro millimetre scale and reveal detailed qualitative and quantitative information of soft and hard tissues. OCT-based high resolution 3D images can provide a significant impact on finding recurrent caries, restorative failure, analysing the precision of crown preparation, and prosthetic elements marginal adaptation error with the gingiva and dental hard tissues. During the CAD/CAM process of prosthodontic restorations, the circumvent of any error is important for the practitioner and the technician to reduce waste of time and material. Additionally, OCT images help to achieve a new or semi-skilled practitioner to analyse their crown preparation works and help to develop their skills faster than in a conventional way. The aim of this study is to highlight the advantages of OCT in high precision prosthodontic restorations. MATERIALS AND METHODS: 25 preparations of frontal and lateral teeth were performed for 7 different patients. The impressions of the prosthetic fields were obtained both using a conventional optoelectronic system (Apolo Di, Syrona) and a Spectral Domain using OCT (Dental prototype, working at 860 nm). For the conventional impression technique the preparation margins were been prelevated by gingival impregnated cords. No specific treatments were performed by the OCT impression technique. RESULTS: The scanning performed by conventional optoelectronic system proved to be quick and accurate in terms of impression technology. The results were represented by 3D virtual models obtained after the scanning procedure was completed. In order to obtain a good optical impression a gingival retraction cord was inserted between the prepared tooth and the gingival

  15. Effects of Lighting Direction on the Impression of Faces and Objects and the Role of Gaze Direction in the Impression-Forming

    Directory of Open Access Journals (Sweden)

    Keiichi Horibata

    2011-10-01

    Full Text Available We examined whether lighting direction, left or right, has an influence on the impression of faces and objects, and the role of gaze direction in the impression-forming. In the first experiment, we examined how lighting directions influenced the impression of faces and objects. On each trial, a pair of faces or objects was presented on top of each other. Left side was brighter in one and right side was brighter in the other. The participants were asked to answer which face or object was more preferable. The results showed that the participants preferred left-brighter faces and objects significantly more frequently than right-brighter stimuli (p < .05, chi-square test. The effect was especially strong in the upright faces. The results suggested that faces and objects give better impressions when they are lit from the left. In the second experiment, we examined whether eye-movement would play a role in our preference for left-brighter faces and objects. We recorded eye-movements of the participants while doing the same task as the first experiment. The results showed that the participants' preference for left-brighter faces were stronger when the participant started viewing from the left. The gaze direction may modulate our impression-formation (Shimojo et al. 2003.

  16. Use of Clinical UV Chamber to Disinfect Dental Impressions: A Comparative Study.

    Science.gov (United States)

    Aeran, Himanshu; Sharma, Sakshi; Kumar, Varun; Gupta, Neelu

    2015-08-01

    Dental impressions are potential source of infection in a prosthodontic practice. Risk of transmission of infection through saliva, blood etc is considered as hazard for both dentist as well as dental auxiliary staff. A number of methods are currently employed for disinfecting the impressions which are technique sensitive and time consuming. This study focuses on disinfecting impression using dental UV chamber which is commonly employed for storing sterilized instruments. The aim of this invitro study was to evaluate the use of clinical UV chamber to disinfect various impression materials at different time intervals and its comparison with 2% glutaraldehyde using standard immersion technique. Total sample size of 180 specimens was taken from three different impression materials. The impressions were made from 30 dentulous subjects. A total of ten impressions were made for each impression material i.e. alginate, addition silicone and polyether impression material. Six punch samples were taken from each impression. Out of 6 punch sample, one was kept as control, second was disinfected by immersing in freshly prepared 2% glutaraldehyde solution for 10 minutes and remaining four were exposed to UV rays for 3 minutes, 6 minutes, 10 minutes and 15 minutes using dental UV chamber. Amount of disinfection achieved was evaluated by counting the colonies over the culture plates with the help of digital colony. The results showed that the mean CFUs for alginate were found to be i.e. 11797.40 ± 5989.73 (mean ± SD). The mean CFUs for addition silicone impression material was found 7095.40 with a standard deviation of 4268.83 and the mean CFUs for polyether impression material was found to be 2168.92 ± 1676 (mean ± SD). For alginate and addition silicone impression material, disinfection was achieved on exposure to UV rays for a period of 10 minutes. However, for polyether impression material 3 minutes of exposure to UV rays was sufficient to cause complete disinfection.

  17. Outcome dependency alters the neural substrates of impression formation

    Science.gov (United States)

    Ames, Daniel L.; Fiske, Susan T.

    2015-01-01

    How do people maintain consistent impressions of other people when other people are often inconsistent? The present research addresses this question by combining recent neuroscientific insights with ecologically meaningful behavioral methods. Participants formed impressions of real people whom they met in a personally involving situation. fMRI and supporting behavioral data revealed that outcome dependency (i.e., depending on another person for a desired outcome) alters previously identified neural dynamics of impression formation. Consistent with past research, a functional localizer identified a region of dorsomedial PFC previously linked to social impression formation. In the main task, this ROI revealed the predicted patterns of activity across outcome dependency conditions: greater BOLD response when information confirmed (vs. violated) social expectations if participants were outcome-independent and the reverse pattern if participants were outcome-dependent. We suggest that, although social perceivers often discount expectancy-disconfirming information as noise, being dependent on another person for a desired outcome focuses impression-formation processing on the most diagnostic information, rather than on the most tractable information. PMID:23850465

  18. Reversible and Irreversible Binding of Nanoparticles to Polymeric Surfaces

    Directory of Open Access Journals (Sweden)

    Wolfgang H. Binder

    2009-01-01

    Full Text Available Reversible and irreversible binding of CdSe-nanoparticles and nanorods to polymeric surfaces via a strong, multiple hydrogen bond (= Hamilton-receptor/barbituric acid is described. Based on ROMP-copolymers, the supramolecular interaction on a thin polymer film is controlled by living polymerization methods, attaching the Hamilton-receptor in various architectures, and concentrations. Strong binding is observed with CdSe-nanoparticles and CdSe-nanorods, whose surfaces are equipped with matching barbituric acid-moieties. Addition of polar solvents, able to break the hydrogen bonds leads to the detachment of the nanoparticles from the polymeric film. Irreversible binding is observed if an azide/alkine-“click”-reaction is conducted after supramolecular recognition of the nanoparticles on the polymeric surface. Thus reversible or irreversible attachment of the nanosized objects can be achieved.

  19. Patients' preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions (Intraoral Scan) of dental implants

    NARCIS (Netherlands)

    Wismeijer, D.; Mans, R.S.; Van Genuchten, M.J.I.M; Reijers, H.A.

    2014-01-01

    Objectives: The primary objective of this clinical study was to assess the patients' perception of the difference between an analogue impression approach on the one hand and an intra-oral scan (IO scan) on the other when restoring implants in the non-aesthetic zone. A second objective was to analyse

  20. Patients' preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions (Intraoral Scan) of dental implants

    NARCIS (Netherlands)

    Wismeijer, D.; Mans, R.; van Genugten, M.; Reijers, H.A.

    2014-01-01

    Objectives The primary objective of this clinical study was to assess the patients' perception of the difference between an analogue impression approach on the one hand and an intra-oral scan (IO scan) on the other when restoring implants in the non-aesthetic zone. A second objective was to analyse

  1. Impression Management: The Web Presence of College Presidents

    Science.gov (United States)

    Morgan, Joanne Cardin

    2013-01-01

    Leadership profile pages on organizational websites have become staged opportunities for impression management. This research uses content analysis to examine the strategies of assertive impression management used to construct the leadership Web presence of the 70 presidents of national public universities, as identified in the "US News and…

  2. Comparison Of The Dimensional Stability Of Alginate Impressions ...

    African Journals Online (AJOL)

    Methodology: Alginate impressions of a master model of truncated metal cones were made and disinfected with 1% sodium hypochlorite constituted from 3.5% household bleach using the spray and immersion technique for 10;20 and 30 minutes. Impressions were cast in dental stone and the linear dimensional differences ...

  3. Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions

    Directory of Open Access Journals (Sweden)

    Ahmad Ghahremanloo

    2017-02-01

    Full Text Available Objectives: The aim of this study was to compare the accuracy of dental implant impressions obtained by a combination of different impression techniques and viscosities of polyvinyl siloxane (PVS.Materials and Methods: Four parallel fixtures were placed between mental foramina in a master model of lower dental arch. Three different viscosities (putty/light body, medium body/light body, and monophase: heavy body and direct and indirect techniques (six groups were used, and seven impressions were obtained from each group (n=42. To measure the accuracy of impressions, drift, horizontal, and vertical angles of the implants, as well as the hex rotation of the implants in casts were evaluated using a digitizer device (1μm accuracy, in comparison with master arch. Data were analyzed using five-factor two-way ANOVA and Tukey’s post-hoc test.Results: The accuracy of impressions was assessed and the results showed that direct technique was not significantly different from indirect technique (P>0.05. Also, there were no significant differences between the mentioned viscosities except for the horizontal angle (P=0.006.Conclusions: Viscosity of impression materials is of high significance for the accuracy of dental impressions.Keywords: Dental Materials; Dental Implants; Dental Impression Technique; Viscosity; Vinyl Polysiloxane; Dimensional Measurement Accuracy

  4. Impressions of functional food consumers.

    Science.gov (United States)

    Saher, Marieke; Arvola, Anne; Lindeman, Marjaana; Lähteenmäki, Liisa

    2004-02-01

    Functional foods provide a new way of expressing healthiness in food choices. The objective of this study was to apply an indirect measure to explore what kind of impressions people form of users of functional foods. Respondents (n=350) received one of eight versions of a shopping list and rated the buyer of the foods on 66 bipolar attributes on 7-point scales. The shopping lists had either healthy or neutral background items, conventional or functional target items and the buyer was described either as a 40-year-old woman or man. The attribute ratings revealed three factors: disciplined, innovative and gentle. Buyers with healthy background items were perceived as more disciplined than those having neutral items on the list, users of functional foods were rated as more disciplined than users of conventional target items only when the background list consisted of neutral items. Buyers of functional foods were regarded as more innovative and less gentle, but gender affected the ratings on gentle dimension. The impressions of functional food users clearly differ from those formed of users of conventional foods with a healthy image. The shopping list method performed well as an indirect method, but further studies are required to test its feasibility in measuring other food-related impressions.

  5. Effects of disinfecting alginate impressions on the scratch hardness of stone models.

    Science.gov (United States)

    Hiraguchi, Hisako; Nakagawa, Hisami; Wakashima, Mitsuru; Miyanaga, Kohichi; Saigo, Masataka; Nishiyama, Minoru

    2006-03-01

    This study investigated the effects of disinfecting alginate impressions on the scratch depth of resultant stone models. Eleven brands of alginate impression material and two disinfectants, 1% sodium hypochlorite and 2% glutaraldehyde, were used. Impressions were immersed in disinfectant solutions or stored in sealed bags after spraying with disinfectants, and then poured with a type V dental stone. The scratch depth of the stone model obtained from disinfected impression was measured. The storage of alginate impressions after spraying with disinfectants did not increase the scratch depth of resultant stone models. However, the effect of immersion in disinfectants on scratch depth varied with the brand of the alginate impression material.

  6. A single-center, prospective, randomized, open-label, clinical trial of ceramide 2-containing hydrocolloid dressings versus polyurethane film dressings for pressure ulcer prevention in high-risk surgical patients

    Directory of Open Access Journals (Sweden)

    Kohta M

    2015-11-01

    Full Text Available Masushi Kohta,1 Kazumi Sakamoto,2 Yasuhiro Kawachi,3 Tsunao Oh-i4 1Medical Engineering Laboratory, ALCARE Co, Ltd, Tokyo, 2Department of Nursing, 3Department of Dermatology, Tokyo Medical University Ibaraki Medical Center, Ibaraki, 4Department of Dermatology, Tokyo Medical University Hachioji Medical Center, Tokyo, Japan Purpose: There have been previous clinical studies regarding the impact of dressings on the prevention of pressure ulcer development. However, it remains unclear whether one type of dressing is better than any other type for preventing ulcer development during surgery. Therefore, we compared the effects of ceramide 2-containing hydrocolloid dressing with film dressings in high-risk patients with regard to reducing the incidence of pressure ulcer development during surgery. Patients and methods: A prospective, randomized, open-label, clinical trial was conducted involving patients who were at a high risk of developing pressure ulcers at a Japanese hospital. The intervention group received ceramide 2-containing hydrocolloid dressings (n=66, and the control group received film dressings (n=64. The primary end point was the incidence rate of pressure ulcer development in both groups; skin damage, such as blanchable erythema, skin discoloration, contact dermatitis, and stripped skin, was recorded as the secondary end point. The relative risk (RR and 95% confidence interval (CI were assessed to compare the probability ratios of pressure ulcer development between the groups. Results: There were significantly fewer patients who developed pressure ulcers in the intervention group than in the control group (RR, 0.37; 95% CI, 0.05–0.99; P=0.04. In the post hoc subgroup analysis, the superiority of the intervention group was more marked when patients had a lower body mass index (P=0.02, lower albumin values (P=0.07, and operation time of 3 hours or more and less than 6 hours (P=0.03. There was no evidence of any statistically significant

  7. The thermomechanics of nonlinear irreversible behaviors an introduction

    CERN Document Server

    Maugin, Gérard A

    1999-01-01

    In this invaluable book, macroscopic irreversible thermodynamics is presented in its realm and its splendor by appealing to the notion of internal variables of state. This applies to both fluids and solids with or without microstructures of mechanical or electromagnetic origin. This unmatched richness of essentially nonlinear behaviors is the result of the use of modern mathematical techniques such as convex analysis in a clear-cut framework which allows one to put under the umbrella of "irreversible thermodynamics" behaviors which until now have been commonly considered either not easily cove

  8. An impressive start

    CERN Multimedia

    2011-01-01

    This has been an excellent week for the LHC, with a succession of fills rapidly increasing the number of proton bunches to 194 per beam. This has allowed the experiments to reach a peak luminosity of 2.5 × 1032 cm-2s-1, thereby surpassing the record for 2010 where we reached 2.0 × 1032 cm-2s-1. At the time of writing, the integrated luminosity delivered by the LHC in 2011 is around 28 inverse picobarns, which is already more than half of the total 2010 dataset.   These are impressive numbers, but what impresses me most is how quickly the LHC operators are now able to turn the machine around between fills, and how well LHC running has been incorporated into the overall operation of CERN’s accelerator complex. The flexibility of the LHC was illustrated on Thursday when we started a short phase of running at 1.38 TeV per beam, equivalent to the energy-per-nucleon of a lead-ion run. This lower energy data will be used by the experiments, in particular by ALICE, to compare...

  9. Time in Science: Reversibility vs. Irreversibility

    Science.gov (United States)

    Pomeau, Yves

    To discuss properly the question of irreversibility one needs to make a careful distinction between reversibility of the equations of motion and the choice of the initial conditions. This is also relevant for the rather confuse philosophy of the wave packet reduction in quantum mechanics. The explanation of this reduction requires also to make precise assumptions on what initial data are accessible in our world. Finally I discuss how a given (and long) time record can be shown in an objective way to record an irreversible or reversible process. Or: can a direction of time be derived from its analysis? This leads quite naturally to examine if there is a possible spontaneous breaking of the time reversal symmetry in many body systems, a symmetry breaking that would be put in evidence objectively by looking at certain specific time correlations.

  10. Intraoral digital impressions to enhance implant esthetics.

    Science.gov (United States)

    Hinds, Kenneth F

    2014-09-01

    Providing an accurate soft-tissue transfer for anterior implants is not a new concept; however, it is currently an especially relevant one. There are numerous documented cases in which residual excess cement with cement-retained implant restorations was a contributing cause in periimplantitis. In 2012, Wadhwani et al reported the importance of placing the crown abutment margins supragingivally for ease of cement removal as a possible solution to address this important issue. Therefore, if placement of the crown abutment margin location is imperative, making an impression that reproduces the soft tissue is equally critical. In 1997, this author introduced the "custom impression coping" to achieve such an accurate transfer. Given the wide use of intraoral digital impressions in 2014, this discussion describes how to fabricate a "custom scan body" using that technology to replicate the transition zone in the virtual environment.

  11. Auditory and visual spatial impression: Recent studies of three auditoria

    Science.gov (United States)

    Nguyen, Andy; Cabrera, Densil

    2004-10-01

    Auditory spatial impression is widely studied for its contribution to auditorium acoustical quality. By contrast, visual spatial impression in auditoria has received relatively little attention in formal studies. This paper reports results from a series of experiments investigating the auditory and visual spatial impression of concert auditoria. For auditory stimuli, a fragment of an anechoic recording of orchestral music was convolved with calibrated binaural impulse responses, which had been made with the dummy head microphone at a wide range of positions in three auditoria and the sound source on the stage. For visual stimuli, greyscale photographs were used, taken at the same positions in the three auditoria, with a visual target on the stage. Subjective experiments were conducted with auditory stimuli alone, visual stimuli alone, and visual and auditory stimuli combined. In these experiments, subjects rated apparent source width, listener envelopment, intimacy and source distance (auditory stimuli), and spaciousness, envelopment, stage dominance, intimacy and target distance (visual stimuli). Results show target distance to be of primary importance in auditory and visual spatial impression-thereby providing a basis for covariance between some attributes of auditory and visual spatial impression. Nevertheless, some attributes of spatial impression diverge between the senses.

  12. Digitization of dental alginate impression: Three-dimensional evaluation of point cloud.

    Science.gov (United States)

    Kim, So-Ri; Lee, Wan-Sun; Kim, Woong-Chul; Kim, Hea-Young; Kim, Ji-Hwan

    2015-01-01

    The purpose of this study was to evaluate the digitization of alginate impressions by analyzing differences between the scan data of two types of impressions (alginate and rubber) taken from the master die and the scan data for the master die. The master die and impressions were digitized using a dental laser scanner (7 series, Dental Wings, Montreal, Canada). The crown portion of the abutment teeth in the digital data of 20 impressions was divided into three regions: cervical surface, middle surface, and occlusal surface. An independent t-test showed a significant difference (palginate and rubber). One-way ANOVA and Tukey's honest significant difference test revealed a significant difference (palginate impressions in the future.

  13. A Framework on Impression Management in Negotiation

    DEFF Research Database (Denmark)

    Mathiasen, Ditte Dahl; Esbjerg, Lars

    2014-01-01

    In this paper we develop a dramaturgical framework to provide us with a new understanding of how negotiators use impression management behaviour during the negotiation process to position themselves in an endeavour to reach a desirable outcome.......In this paper we develop a dramaturgical framework to provide us with a new understanding of how negotiators use impression management behaviour during the negotiation process to position themselves in an endeavour to reach a desirable outcome....

  14. Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions.

    Science.gov (United States)

    Ghahremanloo, Ahmad; Seifi, Mahdieh; Ghanbarzade, Jalil; Abrisham, Seyyed Mohammad; Javan, Rashid Abdolah

    2017-01-01

    The aim of this study was to compare the accuracy of dental implant impressions obtained by a combination of different impression techniques and viscosities of polyvinyl siloxane (PVS). Four parallel fixtures were placed between mental foramina in a master model of lower dental arch. Three different viscosities (putty/light body, medium body/light body, and monophase: heavy body) and direct and indirect techniques (six groups) were used, and seven impressions were obtained from each group (n=42). To measure the accuracy of impressions, drift, horizontal, and vertical angles of the implants, as well as the hex rotation of the implants in casts were evaluated using a digitizer device (1μm accuracy), in comparison with master arch. Data were analyzed using five-factor two-way ANOVA and Tukey's post-hoc test. The accuracy of impressions was assessed and the results showed that direct technique was not significantly different from indirect technique (P>0.05). Also, there were no significant differences between the mentioned viscosities except for the horizontal angle (P=0.006). Viscosity of impression materials is of high significance for the accuracy of dental impressions.

  15. Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance.

    Science.gov (United States)

    Atieh, Mohammad A; Ritter, André V; Ko, Ching-Chang; Duqum, Ibrahim

    2017-09-01

    Trueness and precision are used to evaluate the accuracy of intraoral optical impressions. Although the in vivo precision of intraoral optical impressions has been reported, in vivo trueness has not been evaluated because of limitations in the available protocols. The purpose of this clinical study was to compare the accuracy (trueness and precision) of optical and conventional impressions by using a novel study design. Five study participants consented and were enrolled. For each participant, optical and conventional (vinylsiloxanether) impressions of a custom-made intraoral Co-Cr alloy reference appliance fitted to the mandibular arch were obtained by 1 operator. Three-dimensional (3D) digital models were created for stone casts obtained from the conventional impression group and for the reference appliances by using a validated high-accuracy reference scanner. For the optical impression group, 3D digital models were obtained directly from the intraoral scans. The total mean trueness of each impression system was calculated by averaging the mean absolute deviations of the impression replicates from their 3D reference model for each participant, followed by averaging the obtained values across all participants. The total mean precision for each impression system was calculated by averaging the mean absolute deviations between all the impression replicas for each participant (10 pairs), followed by averaging the obtained values across all participants. Data were analyzed using repeated measures ANOVA (α=.05), first to assess whether a systematic difference in trueness or precision of replicate impressions could be found among participants and second to assess whether the mean trueness and precision values differed between the 2 impression systems. Statistically significant differences were found between the 2 impression systems for both mean trueness (P=.010) and mean precision (P=.007). Conventional impressions had higher accuracy with a mean trueness of 17.0

  16. The Importance of Subtextual Impression Management and Business Faculty.

    Science.gov (United States)

    Chaney, Lillian H.; Lyden, Julie A.

    1998-01-01

    College students (n=265) reported their impressions of business faculty's personal appearance, body language, behavior, and office appearance. Findings indicate that impression management is useful for professors who want to convey credibility, authority, and interest in students. (JOW)

  17. Production of a calcium silicate cement material from alginate impression material.

    Science.gov (United States)

    Washizawa, Norimasa; Narusawa, Hideaki; Tamaki, Yukimichi; Miyazaki, Takashi

    2012-01-01

    The purpose of this study was to synthesize biomaterials from daily dental waste. Since alginate impression material contains silica and calcium salts, we aimed to synthesize calcium silicate cement from alginate impression material. Gypsum-based investment material was also investigated as control. X-ray diffraction analyses revealed that although firing the set gypsum-based and modified investment materials at 1,200°C produced calcium silicates, firing the set alginate impression material did not. However, we succeeded when firing the set blend of pre-fired set alginate impression material and gypsum at 1,200°C. SEM observations of the powder revealed that the featured porous structures of diatomite as an alginate impression material component appeared useful for synthesizing calcium silicates. Experimentally fabricated calcium silicate powder was successfully mixed with phosphoric acid solution and set by depositing the brushite. Therefore, we conclude that the production of calcium silicate cement material is possible from waste alginate impression material.

  18. Dimensional Changes of Alginate Dental Impression Materials-An Invitro Study.

    Science.gov (United States)

    Kulkarni, Manisha M; Thombare, Ram U

    2015-08-01

    Dentists are always looking ahead for more dimensionally stable material for accurate and successful fabrication of prosthesis in this competitive world. Arrival of newer materials and increased material market puts dentists in dilemma for selection of material. The study evaluated the effect of variations in time of pour and temperature on dimensional stability of three brands of commercially available alginates. Velplast, Marieflex & Zelgan alginate impression materials were evaluated by measuring dimensional accuracy of the master cast. A die was prepared and mounted on the apparatus for the ease of impression making. The prepared casts were categorized into five groups and made up of three brands of alginate impression material with variation in time of pour viz: immediate, 20&40 minutes interval and with varying temperature of 25(0)C, 30(0)C & 40(0)C. Impressions showed least distortion at varying degrees of temperature for 20 minutes, but the values obtained by storing of alginate impressions for 20 minutes at 30(0)C were found to be nearly accurate than the values obtained by storing of impression at 40(0)C. However, storing showed shrinkage of impressions. Marieflex showed better accuracy in comparison with other two materials. Maintenance of temperature and humidity play key role during storage & transport to prevent distortion. But the study suggests immediate pouring which will minimize the distortion. The manipulation instructions, temperature of mixing water, environment & water powder ratio also plays key role in minimizing the distortion.

  19. Irreversibility and Action of the Heat Conduction Process

    Directory of Open Access Journals (Sweden)

    Yu-Chao Hua

    2018-03-01

    Full Text Available Irreversibility (that is, the “one-sidedness” of time of a physical process can be characterized by using Lyapunov functions in the modern theory of stability. In this theoretical framework, entropy and its production rate have been generally regarded as Lyapunov functions in order to measure the irreversibility of various physical processes. In fact, the Lyapunov function is not always unique. In the represent work, a rigorous proof is given that the entransy and its dissipation rate can also serve as Lyapunov functions associated with the irreversibility of the heat conduction process without the conversion between heat and work. In addition, the variation of the entransy dissipation rate can lead to Fourier’s heat conduction law, while the entropy production rate cannot. This shows that the entransy dissipation rate, rather than the entropy production rate, is the unique action for the heat conduction process, and can be used to establish the finite element method for the approximate solution of heat conduction problems and the optimization of heat transfer processes.

  20. Functional Impressions in Complete Denture and Overdenture Treatment

    Directory of Open Access Journals (Sweden)

    Hrvoje Kršek

    2015-01-01

    Full Text Available Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fabrication of complete dentures and overdentures, using standardized techniques and materials. An accurate functional impression together with other correctly performed clinical and laboratory procedures ensure good retention and stability of dentures, which is a precondition for restoring patients’ lost functions.

  1. Impression Management and the Control of Social Anxieties.

    Science.gov (United States)

    Miller, Rowland S.

    Impression management refers to the concept that people engaged in interaction will attempt to control the image of themselves that others form. This provides a foundation for social interaction, giving others information about who we are and what to expect from us. A central concern of impression management is the manner in which we are evaluated…

  2. Multiscale Analysis of Time Irreversibility Based on Phase-Space Reconstruction and Horizontal Visibility Graph Approach

    Science.gov (United States)

    Zhang, Yongping; Shang, Pengjian; Xiong, Hui; Xia, Jianan

    Time irreversibility is an important property of nonequilibrium dynamic systems. A visibility graph approach was recently proposed, and this approach is generally effective to measure time irreversibility of time series. However, its result may be unreliable when dealing with high-dimensional systems. In this work, we consider the joint concept of time irreversibility and adopt the phase-space reconstruction technique to improve this visibility graph approach. Compared with the previous approach, the improved approach gives a more accurate estimate for the irreversibility of time series, and is more effective to distinguish irreversible and reversible stochastic processes. We also use this approach to extract the multiscale irreversibility to account for the multiple inherent dynamics of time series. Finally, we apply the approach to detect the multiscale irreversibility of financial time series, and succeed to distinguish the time of financial crisis and the plateau. In addition, Asian stock indexes away from other indexes are clearly visible in higher time scales. Simulations and real data support the effectiveness of the improved approach when detecting time irreversibility.

  3. A Paradigm shift in the concept for making dental impressions.

    Science.gov (United States)

    Nayar, Sanjna; Mahadevan, R

    2015-04-01

    Digital dental impression is a revolutionary technological advancement that so surpasses the accuracy and efficiency of former techniques for obtaining replicas of prepared teeth for the purpose of fabricating restorations that its adoption by dentists is rapidly eclipsing the use of elastomeric impression materials. The ultimate goals of dentists dedicated to quality restorative dentistry are to make their treatment of patients as accurate, stressless, and efficient as possible. By elimination of the everyday problems described above, there is no question that the significant advantages of digital impressions will make intraoral digital scanning standard procedure in most dental offices within the next several years. Furthermore, digital impressions have proven to reduce remakes and returns, as well as increase overall efficiency. The patient also benefits by being provided a far more positive experience. Finally, through the use of digital impression making, it has been determined that laboratory products become more consistent and require less chair time at insertion.

  4. A Paradigm shift in the concept for making dental impressions

    Directory of Open Access Journals (Sweden)

    Sanjna Nayar

    2015-01-01

    Full Text Available Digital dental impression is a revolutionary technological advancement that so surpasses the accuracy and efficiency of former techniques for obtaining replicas of prepared teeth for the purpose of fabricating restorations that its adoption by dentists is rapidly eclipsing the use of elastomeric impression materials. The ultimate goals of dentists dedicated to quality restorative dentistry are to make their treatment of patients as accurate, stressless, and efficient as possible. By elimination of the everyday problems described above, there is no question that the significant advantages of digital impressions will make intraoral digital scanning standard procedure in most dental offices within the next several years. Furthermore, digital impressions have proven to reduce remakes and returns, as well as increase overall efficiency. The patient also benefits by being provided a far more positive experience. Finally, through the use of digital impression making, it has been determined that laboratory products become more consistent and require less chair time at insertion.

  5. A kinetic equation for irreversible aggregation

    International Nuclear Information System (INIS)

    Zanette, D.H.

    1990-09-01

    We introduce a kinetic equation for describing irreversible aggregation in the ballistic regime, including velocity distributions. The associated evolution for the macroscopic quantities is studied, and the general solution for Maxwell interaction models is obtained in the Fourier representation. (author). 23 refs

  6. Work plan for testing silicone impression material and fixture on pool cell capsule

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this work plan is to provide a safe procedure to test a cesium capsule impression fixture at Waste Encapsulation and Storage Facility (WESF). The impression will be taken with silicone dental impression material pressed down upon the capsule using the impression fixture. This test will evaluate the performance of the fixture and impression material under high radiation and temperature conditions on a capsule in a WESF pool cell

  7. Anisotropic shift of the irreversibility line by neutron irradiation

    International Nuclear Information System (INIS)

    Sauerzopf, F.M.; Wiesinger, H.P.; Weber, H.W.; Crabtree, G.W.; Frischherz, M.C.; Kirk, M.A.

    1991-09-01

    The irreversibility line of high-T c superconductors is shifted considerably by irradiating the material with fast neutrons. The anisotropic and non-monotonous shift is qualitatively explained by a simple model based on an interaction between three pinning mechanisms, the intrinsic pinning by the ab-planes, the weak pinning by the pre-irradiation defect structure, and strong pinning by neutron induced defect cascades. A correlation between the cascade density and the position of the irreversibility line is observed

  8. Measures of thermodynamic irreversibility in deterministic and stochastic dynamics

    International Nuclear Information System (INIS)

    Ford, Ian J

    2015-01-01

    It is generally observed that if a dynamical system is sufficiently complex, then as time progresses it will share out energy and other properties amongst its component parts to eliminate any initial imbalances, retaining only fluctuations. This is known as energy dissipation and it is closely associated with the concept of thermodynamic irreversibility, measured by the increase in entropy according to the second law. It is of interest to quantify such behaviour from a dynamical rather than a thermodynamic perspective and to this end stochastic entropy production and the time-integrated dissipation function have been introduced as analogous measures of irreversibility, principally for stochastic and deterministic dynamics, respectively. We seek to compare these measures. First we modify the dissipation function to allow it to measure irreversibility in situations where the initial probability density function (pdf) of the system is asymmetric as well as symmetric in velocity. We propose that it tests for failure of what we call the obversibility of the system, to be contrasted with reversibility, the failure of which is assessed by stochastic entropy production. We note that the essential difference between stochastic entropy production and the time-integrated modified dissipation function lies in the sequence of procedures undertaken in the associated tests of irreversibility. We argue that an assumed symmetry of the initial pdf with respect to velocity inversion (within a framework of deterministic dynamics) can be incompatible with the Past Hypothesis, according to which there should be a statistical distinction between the behaviour of certain properties of an isolated system as it evolves into the far future and the remote past. Imposing symmetry on a velocity distribution is acceptable for many applications of statistical physics, but can introduce difficulties when discussing irreversible behaviour. (paper)

  9. Extrusion-mixing compared with hand-mixing of polyether impression materials?

    Science.gov (United States)

    McMahon, Caroline; Kinsella, Daniel; Fleming, Garry J P

    2010-12-01

    The hypotheses tested were two-fold (a) whether altering the base:catalyst ratio influences working time, elastic recovery and strain in compression properties of a hand-mixed polyether impression material and (b) whether an extrusion-mixed polyether impression material would have a significant advantage over a hand-mixed polyether impression material mixed to the optimum base:catalyst ratio. The polyether was hand-mixed at the optimum (manufacturers recommended) base:catalyst ratios (7:1) and further groups were made by increasing or decreasing the catalyst length by 25%. Additionally specimens were also made from an extrusion-mixed polyether impression material and compared with the optimum hand-mixed base:catalyst ratio. A penetrometer assembly was used to measure the working time (n=5). Five cylindrical specimens for each hand-mixed and extrusion mixed group investigated were employed for elastic recovery and strain in compression testing. Hand-mixing polyether impression materials with 25% more catalyst than that recommended significantly decreased the working time while hand-mixing with 25% less catalyst than that recommended significantly increased the strain in compression. The extrusion-mixed polyether impression material provided similar working time, elastic recovery and strain in compression to the hand-mixed polyether mixed at the optimum base:catalyst ratio.

  10. The public impression of radiation as a product of science communication

    International Nuclear Information System (INIS)

    Kim, Hak Soo; Ha, Hyo Suk; Oh, Mi Young; Choi, Jin Myeung

    2008-01-01

    The purpose of this study is to observe how the public impression of radiation is changing over the North Korea’s nuclear bomb test. We found that the nuclear bomb test brought more negative impressions of radiation, but, in one year, more positive ones prevailed as in the pre-bomb-test. Those positive impressions were found to be composed of useful and positive elements mostly relative to health care. This suggests that we need to apply radiation (fusion) technology to solving everyday life problems in order to bring more positive impressions of radiation

  11. Fundamental economic irreversibilities influence policies for enhancing international forest phytosanitary security

    Science.gov (United States)

    Thomas P. Holmes; Will Allen; Robert G. Haight; E. Carina H. Keskitalo; Mariella Marzano; Maria Pettersson; Christopher P. Quine; E. R. Langer

    2017-01-01

    National and international efforts to manage forest biosecurity create tension between opposing sources of ecological and economic irreversibility. Phytosanitary policies designed to protect national borders from biological invasions incur sunk costs deriving from economic and political irreversibilities that incentivizes wait-and-see decision-making. However, the...

  12. Three-dimensional accuracy of different impression techniques for dental implants

    Directory of Open Access Journals (Sweden)

    Mohammadreza Nakhaei

    2015-01-01

    Full Text Available Background: Accurate impression making is an essential prerequisite for achieving a passive fit between the implant and the superstructure. The aim of this in vitro study was to compare the three-dimensional accuracy of open-tray and three closed-tray impression techniques. Materials and Methods: Three acrylic resin mandibular master models with four parallel implants were used: Biohorizons (BIO, Straumann tissue-level (STL, and Straumann bone-level (SBL. Forty-two putty/wash polyvinyl siloxane impressions of the models were made using open-tray and closed-tray techniques. Closed-tray impressions were made using snap-on (STL model, transfer coping (TC (BIO model and TC plus plastic cap (TC-Cap (SBL model. The impressions were poured with type IV stone, and the positional accuracy of the implant analog heads in each dimension (x, y and z axes, and the linear displacement (ΔR were evaluated using a coordinate measuring machine. Data were analyzed using ANOVA and post-hoc Tukey tests (α = 0.05. Results: The ΔR values of the snap-on technique were significantly lower than those of TC and TC-Cap techniques (P < 0.001. No significant differences were found between closed and open impression techniques for STL in Δx, Δy, Δz and ΔR values (P = 0.444, P = 0.181, P = 0.835 and P = 0.911, respectively. Conclusion: Considering the limitations of this study, the snap-on implant-level impression technique resulted in more three-dimensional accuracy than TC and TC-Cap, but it was similar to the open-tray technique.

  13. The quality of impressions for crowns and bridges: an assessment of the work received at three commercial dental laboratories. assessing qualities of impressions that may lead to occlusal discrepancies with indirect restorations.

    Science.gov (United States)

    Storey, D; Coward, T J

    2014-03-01

    There are few published studies that directly assess the quality of impressions for crowns and bridges in the UK. This paper considers aspects of impression quality with particular attention to factors causing potential occlusal discrepancies in the final restoration. To this end three dental laboratories were visited over a 3-month period. All impressions for conventional crown and bridgework that arrived on the days of the visits were examined and assessed against criteria defined on a custom-designed assessment form. A total of 206 impression cases were considered in this study. Flexible impression trays were used for 65% of working impressions. Their use was more common for NHS work than for private work. 31.9% of all alginate impressions examined were not adequately fixed to the tray. Visible contamination of impressions was not uncommon.

  14. The use of TiO2 nanoparticles to reduce refrigerator ir-reversibility

    International Nuclear Information System (INIS)

    Padmanabhan, Venkataramana Murthy V.; Palanisamy, Senthilkumar

    2012-01-01

    Highlights: ► COP of hydrocarbons mixture VCRSs increases less when compared to R134a. ► Compressor ir-reversibility of VCRSs decreases by 33% (R134a), 14% (R436A and R436B). ► Total ir-reversibility of selected VCRSs decreases. ► Exergy efficiency of R134a is exceptionally low at lower reference temperature. ► Exergy efficiency of selected VCRSs increases. - Abstract: The ir-reversibility at the process of a vapour-compression refrigeration system (VCRS) with nanoparticles in the working fluid was investigated experimentally. Mineral oil (MO) with 0.1 g L −1 TiO 2 nanoparticles mixture were used as the lubricant instead of Polyol-ester (POE) oil in the R134a, R436A (R290/R600a-56/44-wt.%) and R436B (R290/R600a-52/48-wt.%)VCRSs. The VCRS ir-reversibility at the process with the nanoparticles was investigated using second law of thermodynamics. The results indicate that R134a, R436A and R436B and MO with TiO 2 nanoparticles work normally and safely in the VCRS. The VCRSs total ir-reversibility (529, 588 and 570 W) at different process was better than the R134a, R436A and R436B and POE oil system (777, 697 and 683 W). The same tests with Al 2 O 3 nanoparticles showed that the different nanoparticles properties have little effect on the VCRS ir-reversibility. Thus, TiO 2 nanoparticles can be used in VCRS with reciprocating compressor to considerably reduce ir-reversibility at the process.

  15. Impression management within the Zulu culture: Exploring tactics in the work context

    OpenAIRE

    Mtshelwane, Debrah; Nel, Jan Alewyn; Brink, Lizelle

    2016-01-01

    Orientation: Impression management tactics are utilised differently by people depending on the situation and the others around them. Research purpose: The purpose of the study was to identify the impression management tactics Zulu people display when they want to impress people in a work context. Motivation for this study: Organisations are competing for talented employees and people who contribute to the return on investment for the organisation. Individuals display impression tactic...

  16. The influence of sequence of impressions on children's anxiety and discomfort.

    Science.gov (United States)

    Kaakko, Tarja; Horn, Michael T; Weinstein, Philip; Kaufman, Eliezer; Leggott, Penelope; Coldwell, Susan E

    2003-01-01

    Laboratory studies with adults and children have found lower pain reports when pain proceeds from high to low rather than from low to high. However, pediatric dentists often ease children into difficult procedures (from easiest to most difficult). This study investigated the influence of order during a clinical procedure that involved taking maxillary and mandibular alginate impressions. Subjects were 24 children aged 5 to 6 years (preoperational stage) and 24 children aged 9 to 10 years (concrete operational stage). Children were randomly assigned to either start with the mandibular (presumed to be easier) or start with the maxillary (presumed to be harder) impressions. Discomfort during the sequence of impressions was measured using the "Affective Facial Scale." A telephone interview was conducted 2 weeks later to evaluate the memory of discomfort. The results indicated that the older children who started with the mandibular (easier) impression and ended with the maxillary (more uncomfortable) impression reported significantly lower discomfort than older children who started with the maxillary impression and ended with the mandibular (Mann-Whitney U, Z = -2.08; P < .037). The same tendency was noted 2 weeks later on a telephone interview. By phone, 92% of the older children who started with the mandibular impression rated the sequence of impressions as "not at all bad," while only 58% of the older children who started with the maxillary impression rated the overall experience as "not at all bad" (chi2 = 3.56, P < .059). The younger children did not show any significant difference in their ratings of discomfort at either of the assessment periods. Consistent with clinical practice, this study observed that older children benefit from beginning an appointment with an easier procedure and working up to a more difficult one.

  17. Trigeminal neuralgia secondary to basilar impression: A case report

    Directory of Open Access Journals (Sweden)

    Maurus Marques de Almeida Holanda

    2015-01-01

    Full Text Available We report a rare case of trigeminal neuralgia. A 23-year-old woman with a history of 1 year of typical trigeminal neuralgia manifested the characteristics of basilar impression. Magnetic resonance imaging (MRI demonstrated basilar impression, deformity of the posterior fossa with asymmetry of petrous bone, and compression of medulla oblongata in the topography of the odontoid apophysis. The operation was performed through a suboccipital craniectomy. The neuralgia disappeared after surgery and remains completely resolved until today. This is the second reported case of trigeminal neuralgia in a patient with basilar impression in Brazil.

  18. Single Stage Silicone Border Molded Closed Mouth Impression Technique-Part II.

    Science.gov (United States)

    Solomon, E G R

    2011-09-01

    Functioning of a complete denture depends to a great extent on the impression technique. Several impression techniques have been described in the literature since the turn of this century when Greene [Clinical courses in dental prothesis, 1916] brothers introduced the first scientific system of recording dental impression. Advocates of each technique have their own claim of superiority over the other. The introduction of elastomeric impression materials [Skinner and Cooper, J Am Dent Assoc 51:523-536, 1955] has made possible new techniques of recording impression for complete denture construction. These rubber like materials are of two types; one has a polysulfide base and is popularily known as polysulfide rubber (Thiokol and Mercaptan). The other variety has a silicone base known as silicone rubber or silicone elastomer. Silicone elastomers are available in four different consistencies; a thin easy flowing light bodied material,a creamy medium bodied material, a highly viscous heavy bodied material and a kneadable putty material. This paper describes an active closed mouth impression technique with one stage border molding using putty silicone material as a substitute for low fusing compound.

  19. Effect of Splinting on Dimensional Accuracy of Impressions Made of Implants with Different Subgingival Alignments.

    Science.gov (United States)

    Beyabanaki, Elaheh; Shamshiri, Ahmed Reza; Alikhasi, Marzieh; Monzavi, Abbas

    2017-01-01

    Placement of implants at deeper levels of gingiva is sometimes inevitable because of issues like esthetics or bone availability. The accuracy of impressions may be affected in these situations. The aim of this in vitro study was to evaluate the effects of splinting and length of impression copings on the accuracy of impressions made of deeply placed implants. A metal model with two parallel implants (Implantium; Dentium) was fabricated. One hundred and twenty impressions were made using the direct impression technique with and without splinting the impression copings (using short and long impression copings). Impressions were made of implants at three subgingival levels (1, 3, and 6 mm) using regular viscosity poly(vinyl siloxane). The impressions were poured with type IV dental stone. Displacements in the x, y, and z axes, as well as rotational discrepancies and interimplant distances were measured with a coordinate measuring machine. Data were analyzed with Kruskal-Wallis, Mann-Whitney, and nonparametric adjusted rank transform tests. There was less rotational displacement using longer impression copings at different subgingival positions of the implants, either with splinted or nonsplinted direct technique (p impressions at different apico-coronal levels of implants than the splinted technique using short impression copings (p impression copings yielded better results than shorter ones in both splinted and nonsplinted techniques. Also, nonsplinted short impression copings produced more accurate impressions than splinted short impression copings. © 2015 by the American College of Prosthodontists.

  20. Impression Management in Survey Responding: Easier for Collectivists or Individualists?

    Science.gov (United States)

    Riemer, Hila; Shavitt, Sharon

    2012-01-01

    Three experiments indicate that when individualists and collectivists engage in impression management on self-reports, they do so through different psychological mechanism s. Collectivists do so through a relatively automatic process. Thus, they can impression manage even when cognitively busy. Individualists impression manage through a more effortful process. Therefore, they can do so only when the situation permits effortful processing. These findings highlight distinct conditions under which social norms may influence consumer self-reports across cultures. PMID:23175618

  1. Impression Management in Survey Responding: Easier for Collectivists or Individualists?

    Science.gov (United States)

    Riemer, Hila; Shavitt, Sharon

    2011-04-01

    Three experiments indicate that when individualists and collectivists engage in impression management on self-reports, they do so through different psychological mechanism s. Collectivists do so through a relatively automatic process. Thus, they can impression manage even when cognitively busy. Individualists impression manage through a more effortful process. Therefore, they can do so only when the situation permits effortful processing. These findings highlight distinct conditions under which social norms may influence consumer self-reports across cultures.

  2. Irreversible Local Markov Chains with Rapid Convergence towards Equilibrium

    Science.gov (United States)

    Kapfer, Sebastian C.; Krauth, Werner

    2017-12-01

    We study the continuous one-dimensional hard-sphere model and present irreversible local Markov chains that mix on faster time scales than the reversible heat bath or Metropolis algorithms. The mixing time scales appear to fall into two distinct universality classes, both faster than for reversible local Markov chains. The event-chain algorithm, the infinitesimal limit of one of these Markov chains, belongs to the class presenting the fastest decay. For the lattice-gas limit of the hard-sphere model, reversible local Markov chains correspond to the symmetric simple exclusion process (SEP) with periodic boundary conditions. The two universality classes for irreversible Markov chains are realized by the totally asymmetric SEP (TASEP), and by a faster variant (lifted TASEP) that we propose here. We discuss how our irreversible hard-sphere Markov chains generalize to arbitrary repulsive pair interactions and carry over to higher dimensions through the concept of lifted Markov chains and the recently introduced factorized Metropolis acceptance rule.

  3. Experimental study on the use of spacer foils in two-step putty and wash impression procedures using silicone impression materials.

    Science.gov (United States)

    Mann, Karsten; Davids, Andreas; Range, Ursula; Richter, Gert; Boening, Klaus; Reitemeier, Bernd

    2015-04-01

    The 2-step putty and wash impression technique is commonly used in fixed prosthodontics. However, cutting sluiceways to allow the light-body material to drain is time-consuming. A solution might be the use of a spacer foil. The purpose of this study was to evaluate the influence of spacer foil on the margin reproduction and dimensional accuracy of 2-step putty and wash impressions. Two methods of creating space for the wash material in a 2-step putty and wash impression were compared: the traditional cutout technique and a spacer foil. Eleven commercially available combinations of silicone impression materials were included in the study. The impressions and the cast production were carried out under standardized conditions. All casts were measured with a 3-dimensional (3D) coordinate measuring machine. Preparation margin reproduction and the diameters and spacing of the stone cast dies were measured (α=.05). The 2 methods showed significant differences (P<.05) in the reproduction of the preparation margins (complete reproduction cutout, 90% to 98%; foil, 74% to 91%). The use of a foil resulted in greater dimensional accuracy of the cast dies compared to the cutout technique. Cast dies from the cutout technique were significantly smaller than the metallic original cast (cutout median, 4.55 mm to 4.61 mm; foil median, 4.61 to 4.64). Spacing between the dies revealed only a few additional significant differences between the techniques. When spacer foils were used, dies were obtained that better corresponded to the original tooth. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Impression management and food intake. Current directions in research.

    Science.gov (United States)

    Vartanian, Lenny R

    2015-03-01

    This paper reviews recent research on consumption stereotypes (judgments of others based on what they eat) and impression management (modifying one's eating behavior in order to create a particular impression). A major recent focus in the literature has been on masculinity and meat eating, with research showing that meat is strongly associated with masculinity, and that individuals who follow a meat-based diet are perceived as more masculine than are individuals who follow a vegetarian diet. Although direct evidence for impression management through food intake remains sparse, a number of methodological approaches (including priming techniques and ecological valid assessments) are described that could be used in future research to identify the motives underlying people's eating behavior. Consumption stereotypes and impression management may be important influences on people's eating behavior, but the complexities of how, when, and for whom these factors influence food intake are still not well understood. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. A Fingerprint Encryption Scheme Based on Irreversible Function and Secure Authentication

    Directory of Open Access Journals (Sweden)

    Yijun Yang

    2015-01-01

    Full Text Available A fingerprint encryption scheme based on irreversible function has been designed in this paper. Since the fingerprint template includes almost the entire information of users’ fingerprints, the personal authentication can be determined only by the fingerprint features. This paper proposes an irreversible transforming function (using the improved SHA1 algorithm to transform the original minutiae which are extracted from the thinned fingerprint image. Then, Chinese remainder theorem is used to obtain the biokey from the integration of the transformed minutiae and the private key. The result shows that the scheme has better performance on security and efficiency comparing with other irreversible function schemes.

  6. Curdlan: an important microbial hydrocolloid/ Goma curdlana: um importante hidrocolóide microbiano

    Directory of Open Access Journals (Sweden)

    Elaine Soares Amorim

    2003-05-01

    Full Text Available The use of gums in the food industry is mainly based in its functional properties, which are related to the capacity to prevent or delay a series of physicals phenomenon, having an important role in the stability of many industrialized food. The use of these in the several food productions is indispensable, because they contribute to thickening, gelling, stabilization, suspension, film formation and gums can act as auxiliary agents of processing. Therefore, our objective was evaluated the chemistries physical properties, as well as, the areas of application of the microbial hydrocolloid, curdlan.O uso das gomas na indústria de alimentos baseia-se principalmente no aproveitamento de suas propriedades funcionais, que estão relacionadas à capacidade de prevenir ou retardar uma série de fenômenos físicos, desempenhando papel importante na estabilidade de muitos alimentos industrializados. É indispensável o uso destas na produção de diversos produtos alimentícios, pois contribuem para o espessamento, gelificação, estabilização, suspensão, formação de filme e podem atuar como agentes auxiliares de processamento. Desta forma, o presente trabalho buscou avaliar as propriedades físico-químicas, bem como, as áreas de aplicação da goma curdlana que é um hidrocolóide de origem microbiana.

  7. Do first impressions count? Frailty judged by initial clinical impression predicts medium-term mortality in vascular surgical patients.

    Science.gov (United States)

    O'Neill, B R; Batterham, A M; Hollingsworth, A C; Durrand, J W; Danjoux, G R

    2016-06-01

    Recognising frailty during pre-operative assessment is important. Frail patients experience higher mortality rates and are less likely to return to baseline functional status following the physiological insult of surgery. We evaluated the association between an initial clinical impression of frailty and all-cause mortality in 392 patients attending our vascular pre-operative assessment clinic. Prevalence of frailty assessed by the initial clinical impression was 30.6% (95% CI 26.0-35.2%). There were 133 deaths in 392 patients over a median follow-up period of 4 years. Using Cox regression, adjusted for age, sex, revised cardiac risk index and surgery (yes/no), the hazard ratio for mortality for frail vs. not-frail was 2.14 (95% CI 1.51-3.05). The time to 20% mortality was 16 months in the frail group and 33 months in the not-frail group. The initial clinical impression is a useful screening tool to identify frail patients in pre-operative assessment. © 2016 The Association of Anaesthetists of Great Britain and Ireland.

  8. Disinfection of Dental Impressions Prior to Handling at Muhimbili ...

    African Journals Online (AJOL)

    All four dental technicians who handled the received impressions were interviewed. Questions asked were on practice and attitudes and responses were on different point scales. Results are based on information gathered from the dental technicians. Results: Of the 1,453 impressions received none were reported to have ...

  9. Obtention and characterization of dried gels prepared with whey proteins, honey and hydrocolloids mixture.

    Science.gov (United States)

    Rodriguez, Ana C; Torrez Irigoyen, Martín R; Navarro, Alba S; Yamul, Diego K

    2017-11-01

    Large amounts of honey and liquid whey derived from the dairy industry are produced in Argentina. Honey is exported in bulk and whey is transformed into whey protein concentrates and isolates. The objective of this work was to investigate the effect of pH, composition and storage time on the properties of dried gels with honey, whey proteins and hydrocolloids. Color properties varied according to pH and composition. The fracture stress of dried gels prepared with corn starch was higher than that of gels prepared with guar gum in all conditions assayed. Young's modulus was higher at pH 7 for both compositions and increased with storage time. Rubbery characteristics were found in dried gels with guar gum, while both corn starch and guar gum made the microstructure rougher. Multivariate analysis showed that samples could be grouped by pH. Panelists preferred pH 7 products over acidic ones, and no significant differences in sensory properties were found using either corn starch or guar gum in the formulation. The results demonstrated that it is possible to generate a new product, which may open new applications for honey and whey in food formulations. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  10. Impression management within the Zulu culture: Exploring tactics in the work context

    Directory of Open Access Journals (Sweden)

    Debrah Mtshelwane

    2016-08-01

    Full Text Available Orientation: Impression management tactics are utilised differently by people depending on the situation and the others around them. Research purpose: The purpose of the study was to identify the impression management tactics Zulu people display when they want to impress people in a work context. Motivation for this study: Organisations are competing for talented employees and people who contribute to the return on investment for the organisation. Individuals display impression tactics to influence the perceptions of others in the workplace, especially pertaining to performance appraisals and promotional opportunities. Research approach, design and method: The social constructivism paradigm was employed in conducting this study, following a phenomenological approach. The research sample consisted of 30 Zulu-speaking individuals from various organisations who were interviewed through semi-structured interviews. The researcher used thematic analysis to analyse the data. Main findings: The main findings in this study included impression management tactics that are used by Zulu people when attempting to impress people in the work context. The findings were divided into different categories (colleagues and supervisor. Conscientiousness,interpersonal amiability, openness and relational action are the themes that were reported as the most common impression management features people display at their workplace with colleagues. Themes that were reported when impressing a supervisor include conscientiousness,integrity, relational action and skilfulness. Practical/managerial implications: This study provides organisations with knowledge on the impression management tactics utilised by isiZulu employees. The nature of this information enables management to not misinterpret the use of certain tactics and will lead to more understanding and resilience by organisations and colleagues when working with isiZulu individuals. Contribution/value-add: This study

  11. Dimensional Stability of Two Polyvinyl Siloxane Impression Materials in Different Time Intervals

    Directory of Open Access Journals (Sweden)

    Aalaei Sh

    2015-12-01

    Full Text Available Statement of the Problem: Dental prosthesis is usually made indirectly; there- fore dimensional stability of the impression material is very important. Every few years, new impression materials with different manufacturers’ claims regarding their better properties are introduced to the dental markets which require more research to evaluate their true dimensional changes. Objectives: The aim of this study was to evaluate dimensional stability of additional silicone impression material (Panasil® and Affinis® in different time intervals. Materials and Methods: In this experimental study, using two additional silicones (Panasil® and Affinis®, we made sixty impressions of standard die in similar conditions of 23 °C and 59% relative humidity by a special tray. The die included three horizontal and two vertical lines that were parallel. The vertical line crossed the horizontal ones at a point that served as reference for measurement. All impressions were poured with high strength dental stone. The dimensions were measured by stereo-microscope by two examiners in three interval storage times (1, 24 and 168 hours.The data were statistically analyzed using t-test and ANOVA. Results: All of the stone casts were larger than the standard die. Dimensional changes of Panasil and Affinis were 0.07%, 0.24%, 0.27% and 0.02%, 0.07%, 0.16% after 1, 24 and 168 hours, respectively. Dimensional change for two impression materials wasn’t significant in the interval time, expect for Panasil after one week (p = 0.004. Conclusions: According to the limitations of this study, Affinis impressions were dimensionally more stable than Panasil ones, but it was not significant. Dimensional change of Panasil impression showed a statistically significant difference after one week. Dimensional changes of both impression materials were based on ADA standard limitation in all time intervals (< 0.5%; therefore, dimensional stability of this impression was accepted at least

  12. Optima and bounds for irreversible thermodynamic processes

    International Nuclear Information System (INIS)

    Hoffmann, K.H.

    1990-01-01

    In this paper bounds and optima for irreversible thermodynamic processes and their application in different fields are discussed. The tools of finite time thermodynamics are presented and especially optimal control theory is introduced. These methods are applied to heat engines, including models of the Diesel engine and a light-driven engine. Further bounds for irreversible processes are introduced, discussing work deficiency and its relation to thermodynamic length. Moreover the problem of dissipation in systems composed of several subsystems is studied. Finally, the methods of finite time thermodynamics are applied to thermodynamic processes described on a more microscopic level. The process used as an example is simulated annealing. It is shown how optimal control theory is applied to find the optimal cooling schedule for this important stochastic optimization method

  13. A minimal dissipation type-based classification in irreversible thermodynamics and microeconomics

    Science.gov (United States)

    Tsirlin, A. M.; Kazakov, V.; Kolinko, N. A.

    2003-10-01

    We formulate the problem of finding classes of kinetic dependencies in irreversible thermodynamic and microeconomic systems for which minimal dissipation processes belong to the same type. We show that this problem is an inverse optimal control problem and solve it. The commonality of this problem in irreversible thermodynamics and microeconomics is emphasized.

  14. Accuracy of the One-Stage and Two-Stage Impression Techniques: A Comparative Analysis.

    Science.gov (United States)

    Jamshidy, Ladan; Mozaffari, Hamid Reza; Faraji, Payam; Sharifi, Roohollah

    2016-01-01

    Introduction . One of the main steps of impression is the selection and preparation of an appropriate tray. Hence, the present study aimed to analyze and compare the accuracy of one- and two-stage impression techniques. Materials and Methods . A resin laboratory-made model, as the first molar, was prepared by standard method for full crowns with processed preparation finish line of 1 mm depth and convergence angle of 3-4°. Impression was made 20 times with one-stage technique and 20 times with two-stage technique using an appropriate tray. To measure the marginal gap, the distance between the restoration margin and preparation finish line of plaster dies was vertically determined in mid mesial, distal, buccal, and lingual (MDBL) regions by a stereomicroscope using a standard method. Results . The results of independent test showed that the mean value of the marginal gap obtained by one-stage impression technique was higher than that of two-stage impression technique. Further, there was no significant difference between one- and two-stage impression techniques in mid buccal region, but a significant difference was reported between the two impression techniques in MDL regions and in general. Conclusion . The findings of the present study indicated higher accuracy for two-stage impression technique than for the one-stage impression technique.

  15. A metric study of insole foot impressions in footwear of identical twins.

    Science.gov (United States)

    Nirenberg, Michael S; Krishan, Kewal; Kanchan, Tanuj

    2017-11-01

    Foot impressions are of utmost importance in crime scene investigations. Foot impressions are available in the form of barefoot prints, sock-clad footprints, and as impressions within footwear. Sometimes suspects leave their footwear at the crime scene, and the insole of this footwear may contain the foot impression of the suspect which may be important evidence linking him or her to the crime. The task of identification based on the analysis of footprints can be challenging when the footprints belonging to one of the identical twin is available for examination. The present study is based on the quantitative measures of the foot impressions in the footwear of adult identical twins. The study was conducted on four sets of female monozygotic twins from the United States of America. A total of 17 length and breadth measurements were taken on each foot impression. A combination of Reel Method and Extended Gunn Method was utilized to produce the measurements. The measurements of the foot impressions were compared among the twins on the right and the left side. Differences were found in the various footprint measurements among the twins. The study's sample size was not large enough to apply robust statistical tests, but the study is significant in that it presents the first detailed comparative analysis of a large number of measurements of insole foot impressions of adult twins. The observations derived from the study are likely to assist forensic investigations in cases involving the foot impressions of the twins. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  16. Optimization of the performance characteristics in an irreversible magnetic Brayton refrigeration cycle

    International Nuclear Information System (INIS)

    Wang Hao; Liu Sanqiu

    2008-01-01

    An irreversible cycle model of magnetic Brayton refrigerators is established, in which the thermal resistance and irreversibility in the two adiabatic processes are taken into account. Expressions for several important performance parameters, such as the coefficient of performance, cooling rate and power input are derived. Moreover, the optimal performance parameters are obtained at the maximum coefficient of performance. The optimization region (or criteria) for an irreversible magnetic Brayton refrigerator is obtained. The results obtained here have general significance and will be helpful to understand deeply the performance of a magnetic Brayton refrigeration cycle

  17. BNNT-mediated irreversible electroporatio: its potential on cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Vittoria Raffa, Cristina Riggio, Michael W. Smith, Kevin C. Jordan, Wei Cao, Alfred Cuschieri

    2012-10-01

    Tissue ablation, i.e., the destruction of undesirable tissues, has become an important minimally invasive technique alternative to resection surgery for the treatment of tumours. Several methods for tissue ablation are based on thermal techniques using cold, e.g. cryosurgery [1] or heat, e.g. radiofrequency [2] or high-intensity focused ultrasound [3] or nanoparticle-mediated irradiation [4]. Alternatively, irreversible electroporation (IRE) has been proposed as non thermal technique for minimally invasive tissue ablation based on the use of electrical pulses. When the electric field is applied to a cell, a change in transmembrane potential is induced, which can cause biochemical and physiological changes of the cell. When the threshold value of the transmembrane potential is exceeded, the cell membrane becomes permeable, thus allowing entrance of molecules that otherwise cannot cross the membrane [5]. A further increase in the electric field intensity may cause irreversible membrane permeabilization and cell death. These pulses create irreversible defects (pores) in the cell membrane lipid bilayer, causing cell death through loss of cell homeostasis [6]. This is desirable in tumour ablation in order to produce large cell death, without the use of cytostatic drugs. A study of Davalos, Mir and Rubinsky showed that IRE can ablate substantial volumes of tissue without inducing a thermal effect and therefore serve as an independent and new tissue ablation modality; this opened the way to the use of IRE in surgery [7]. Their finding was subsequently confirmed in studies on cells [8], small animal models [9] and in large animal models in the liver [10] and the heart [11]. The most important finding in these papers is that irreversible electroporation produces precisely delineated ablation zones with cell scale resolution between ablated and non-ablated areas, without zones in which the extent of damage changes gradually as during thermal ablation. Furthermore, it is

  18. Impression Procedures for Metal Frame Removable Partial Dentures as Applied by General Dental Practitioners.

    Science.gov (United States)

    Fokkinga, Wietske A; van Uchelen, Judith; Witter, Dick J; Mulder, Jan; Creugers, Nico H J

    2016-01-01

    This pilot study analyzed impression procedures for conventional metal frame removable partial dentures (RPDs). Heads of RPD departments of three dental laboratories were asked to record features of all incoming impressions for RPDs during a 2-month period. Records included: (1) impression procedure, tray type (stock/custom), impression material (elastomer/alginate), use of border-molding material (yes/no); and (2) RPD type requested (distal-extension/tooth-bounded/combination). Of the 132 total RPD impressions, 111 (84%) involved custom trays, of which 73 (55%) were combined with an elastomer. Impression border-molding material was used in 4% of the cases. Associations between impression procedure and RPD type or dentists' year/university of graduation were not found.

  19. Functional Impressions in Complete Denture and Overdenture Treatment

    OpenAIRE

    Hrvoje Kršek; Nikša Dulčić

    2015-01-01

    Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fab...

  20. Evaluation of oral scanning in comparison to impression using three-dimensional registration

    Science.gov (United States)

    Brogle-Kim, Yur-Chung; Deyhle, Hans; Müller, Bert; Schulz, Georg; Bormann, Therese; Beckmann, Felix; Jäger, Kurt

    2012-10-01

    Crown and bridge restorations are one of the main treatment methods in fixed prosthodontics. The fabrication requires data on the patient's denture shape. This information is generally obtained as a hard copy from an impression mold. Alternatively, one can acquire the data electronically using oral optical three-dimensional (3D) imaging techniques, which determine the surface of the denture. The aim of the study was to quantitatively compare the accuracy of three dimensional scanning with that of conventional impressions and give a statement how far the scanner provides a clinical alternative with equal or better precision. Data from 10 teeth were acquired in the dental office with a polyether impression material and an oral scanner. Data from the impressions were digitalized by means of micro computed tomography. The data were then 3D registered to identify the potential differences between impression and optical scan. We could demonstrate that the oral scanner's data and the conventional impressions are comparable.

  1. Fluctuation theorems in feedback-controlled open quantum systems: Quantum coherence and absolute irreversibility

    Science.gov (United States)

    Murashita, Yûto; Gong, Zongping; Ashida, Yuto; Ueda, Masahito

    2017-10-01

    The thermodynamics of quantum coherence has attracted growing attention recently, where the thermodynamic advantage of quantum superposition is characterized in terms of quantum thermodynamics. We investigate the thermodynamic effects of quantum coherent driving in the context of the fluctuation theorem. We adopt a quantum-trajectory approach to investigate open quantum systems under feedback control. In these systems, the measurement backaction in the forward process plays a key role, and therefore the corresponding time-reversed quantum measurement and postselection must be considered in the backward process, in sharp contrast to the classical case. The state reduction associated with quantum measurement, in general, creates a zero-probability region in the space of quantum trajectories of the forward process, which causes singularly strong irreversibility with divergent entropy production (i.e., absolute irreversibility) and hence makes the ordinary fluctuation theorem break down. In the classical case, the error-free measurement ordinarily leads to absolute irreversibility, because the measurement restricts classical paths to the region compatible with the measurement outcome. In contrast, in open quantum systems, absolute irreversibility is suppressed even in the presence of the projective measurement due to those quantum rare events that go through the classically forbidden region with the aid of quantum coherent driving. This suppression of absolute irreversibility exemplifies the thermodynamic advantage of quantum coherent driving. Absolute irreversibility is shown to emerge in the absence of coherent driving after the measurement, especially in systems under time-delayed feedback control. We show that absolute irreversibility is mitigated by increasing the duration of quantum coherent driving or decreasing the delay time of feedback control.

  2. Interpretation of appearance: the effect of facial features on first impressions and personality

    DEFF Research Database (Denmark)

    Wolffhechel, Karin Marie Brandt; Fagertun, Jens; Jacobsen, Ulrik Plesner

    2014-01-01

    Appearance is known to influence social interactions, which in turn could potentially influence personality development. In this study we focus on discovering the relationship between self-reported personality traits, first impressions and facial characteristics. The results reveal that several...... personality traits can be read above chance from a face, and that facial features influence first impressions. Despite the former, our prediction model fails to reliably infer personality traits from either facial features or first impressions. First impressions, however, could be inferred more reliably from...... facial features. We have generated artificial, extreme faces visualising the characteristics having an effect on first impressions for several traits. Conclusively, we find a relationship between first impressions, some personality traits and facial features and consolidate that people on average assess...

  3. Maxillary anterior tooth dimensions and proportions in an Irish young adult population.

    LENUS (Irish Health Repository)

    Condon, M

    2011-07-01

    This study was undertaken in a young Irish population to determine the dimensions and ratios of the six maxillary anterior teeth. One hundred and nine Irish subjects (age 18-25 inclusive) had irreversible hydrocolloid impressions made of their maxillary dentition poured in type V stone. Clinical crown dimensions were measured with a digital calliper. The stone casts were digitally photographed in a standardised manner enabling calculation of various ratios between the maxillary anterior teeth. Sexual dimorphism existed for various tooth dimensions; most notably canine teeth were in the region of 0·8 mm longer and 0·6 mm wider in males. Central and lateral incisors were found to be 0·5 mm wider in males. It is, therefore, recommended that dimensional tooth guidelines should be given for each of the sexes and not on a population basis. With regard to tooth proportion ratios, no significant differences were found between genders or the left and right sides for any of the measurements or ratios measured. The digitally recorded tooth proportions were similar for both sexes, and the Golden Proportion guidelines could only be applied to the lateral incisor\\/central incisor widths (0·618). Identified width proportions for the canine\\/central incisor were 0·58 and for canine\\/lateral incisor 0·89.

  4. Collection of Wet-Origin Footwear Impressions on Various Surfaces Using an Electrostatic Dust Print Lifter.

    Science.gov (United States)

    Hong, Sungwook; Park, Miseon

    2018-01-19

    Electrostatic dust print lift method is known to be able to recover only dry-origin footwear impression. However, the wet-origin footwear impression could also be recovered using this method. As the amount of dust accumulated before deposition of the wet-origin footwear impression increased, the intensity of the footwear impression lifted with this method became stronger. If the footwear impression is not affected by moisture after it is made, the 28-h old wet-origin footwear impression could be recovered using this method. The intensity of the lifted footwear impression did not decrease significantly even when the number of sequential steps increased as long as the shoe sole is wet. However, when the moisture on the shoe sole depleted, the intensity of the footwear impression decreased sharply. This method has the advantage of being able to enhance the footwear impression without being affected by the footwear impressions deposited in the past. © 2018 American Academy of Forensic Sciences.

  5. Three-dimensional accuracy of a digitally coded healing abutment implant impression system.

    Science.gov (United States)

    Ng, Simon D; Tan, Keson B; Teoh, K H; Cheng, Ansgar C; Nicholls, Jack I

    2014-01-01

    This study examined the three-dimensional (3D) accuracy of the Encode Impression System (EN) in transferring the locations of two implants from master models to test models and compared this to the direct impression (DI) technique. The effect of interimplant angulation on the 3D accuracy of both impression techniques was also evaluated. Seven sectional polymethyl methacrylate mandibular arch master models were fabricated with implants in the first premolar and first molar positions. The implants were placed parallel to each other or angulated mesiodistally or buccolingually with total divergent angles of 10, 20, or 30 degrees. Each master model was secured onto an aluminum block containing a gauge block, which defined the local coordinate references. Encode healing abutments were attached to the implants before impressions were made for the EN test models; pickup impression copings were attached for the DI test models. For the seven test groups of each impression technique, a total of 70 test models were fabricated (n = 5). The EN test models were sent to Biomet 3i for implant analog placement. The centroid of each implant or implant analog and the angular orientation of the long axis relative to the x- and y-axes were measured with a coordinate measuring machine. Statistical analyses were performed. Impression technique had a significant effect on y distortion, global linear distortion, and absolute xz and yz angular distortions. Interimplant angulation had significant effects on x and y distortions. However, neither impression technique nor interimplant angulation had a significant effect on z distortion. Distortions were observed with both impression techniques. However, the results suggest that EN was less accurate than DI.

  6. Accuracy of the One-Stage and Two-Stage Impression Techniques: A Comparative Analysis

    Directory of Open Access Journals (Sweden)

    Ladan Jamshidy

    2016-01-01

    Full Text Available Introduction. One of the main steps of impression is the selection and preparation of an appropriate tray. Hence, the present study aimed to analyze and compare the accuracy of one- and two-stage impression techniques. Materials and Methods. A resin laboratory-made model, as the first molar, was prepared by standard method for full crowns with processed preparation finish line of 1 mm depth and convergence angle of 3-4°. Impression was made 20 times with one-stage technique and 20 times with two-stage technique using an appropriate tray. To measure the marginal gap, the distance between the restoration margin and preparation finish line of plaster dies was vertically determined in mid mesial, distal, buccal, and lingual (MDBL regions by a stereomicroscope using a standard method. Results. The results of independent test showed that the mean value of the marginal gap obtained by one-stage impression technique was higher than that of two-stage impression technique. Further, there was no significant difference between one- and two-stage impression techniques in mid buccal region, but a significant difference was reported between the two impression techniques in MDL regions and in general. Conclusion. The findings of the present study indicated higher accuracy for two-stage impression technique than for the one-stage impression technique.

  7. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques.

    Directory of Open Access Journals (Sweden)

    Emi Kamimura

    Full Text Available The aim of this study was to evaluate and compare the inter-operator reproducibility of three-dimensional (3D images of teeth captured by a digital impression technique to a conventional impression technique in vivo.Twelve participants with complete natural dentition were included in this study. A digital impression of the mandibular molars of these participants was made by two operators with different levels of clinical experience, 3 or 16 years, using an intra-oral scanner (Lava COS, 3M ESPE. A silicone impression also was made by the same operators using the double mix impression technique (Imprint3, 3M ESPE. Stereolithography (STL data were directly exported from the Lava COS system, while STL data of a plaster model made from silicone impression were captured by a three-dimensional (3D laboratory scanner (D810, 3shape. The STL datasets recorded by two different operators were compared using 3D evaluation software and superimposed using the best-fit-algorithm method (least-squares method, PolyWorks, InnovMetric Software for each impression technique. Inter-operator reproducibility as evaluated by average discrepancies of corresponding 3D data was compared between the two techniques (Wilcoxon signed-rank test.The visual inspection of superimposed datasets revealed that discrepancies between repeated digital impression were smaller than observed with silicone impression. Confirmation was forthcoming from statistical analysis revealing significantly smaller average inter-operator reproducibility using a digital impression technique (0.014± 0.02 mm than when using a conventional impression technique (0.023 ± 0.01 mm.The results of this in vivo study suggest that inter-operator reproducibility with a digital impression technique may be better than that of a conventional impression technique and is independent of the clinical experience of the operator.

  8. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques

    Science.gov (United States)

    Kamimura, Emi; Tanaka, Shinpei; Takaba, Masayuki; Tachi, Keita; Baba, Kazuyoshi

    2017-01-01

    Purpose The aim of this study was to evaluate and compare the inter-operator reproducibility of three-dimensional (3D) images of teeth captured by a digital impression technique to a conventional impression technique in vivo. Materials and methods Twelve participants with complete natural dentition were included in this study. A digital impression of the mandibular molars of these participants was made by two operators with different levels of clinical experience, 3 or 16 years, using an intra-oral scanner (Lava COS, 3M ESPE). A silicone impression also was made by the same operators using the double mix impression technique (Imprint3, 3M ESPE). Stereolithography (STL) data were directly exported from the Lava COS system, while STL data of a plaster model made from silicone impression were captured by a three-dimensional (3D) laboratory scanner (D810, 3shape). The STL datasets recorded by two different operators were compared using 3D evaluation software and superimposed using the best-fit-algorithm method (least-squares method, PolyWorks, InnovMetric Software) for each impression technique. Inter-operator reproducibility as evaluated by average discrepancies of corresponding 3D data was compared between the two techniques (Wilcoxon signed-rank test). Results The visual inspection of superimposed datasets revealed that discrepancies between repeated digital impression were smaller than observed with silicone impression. Confirmation was forthcoming from statistical analysis revealing significantly smaller average inter-operator reproducibility using a digital impression technique (0.014± 0.02 mm) than when using a conventional impression technique (0.023 ± 0.01 mm). Conclusion The results of this in vivo study suggest that inter-operator reproducibility with a digital impression technique may be better than that of a conventional impression technique and is independent of the clinical experience of the operator. PMID:28636642

  9. Developing the Perfect Pitch: Creating a Positive First Impression through Social Media

    Science.gov (United States)

    Edmiston, Dawn

    2016-01-01

    Too often we take for granted first impressions and how others perceive us, but such perceptions frequently form the basis for personal and professional success. Today, many first impressions are made online through search engine results and social networks. To ensure that students make a positive first impression, this teaching innovation…

  10. Irreversible adsorption of phenolic compounds by activated carbons

    Energy Technology Data Exchange (ETDEWEB)

    Grant, T.M.; King, C.J.

    1988-12-01

    Studies were undertaken to determine the reasons why phenolic sorbates can be difficult to remove and recover from activated carbons. The chemical properties of the sorbate and the adsorbent surface, and the influences of changes in the adsorption and desorption conditions were investigated. Comparison of isotherms established after different contact times or at different temperatures indicated that phenolic compounds react on carbon surfaces. The reaction rate is a strong function of temperature. Regeneration of carbons by leaching with acetone recovered at least as much phenol as did regeneration with other solvents or with displacers. The physiochemical properties of adsorbents influences irreversible uptakes. Sorbates differed markedly in their tendencies to undergo irreversible adsorption. 64 refs., 47 figs., 32 tabs.

  11. Irreversible adsorption of phenolic compounds by activated carbons

    International Nuclear Information System (INIS)

    Grant, T.M.; King, C.J.

    1988-12-01

    Studies were undertaken to determine the reasons why phenolic sorbates can be difficult to remove and recover from activated carbons. The chemical properties of the sorbate and the adsorbent surface, and the influences of changes in the adsorption and desorption conditions were investigated. Comparison of isotherms established after different contact times or at different temperatures indicated that phenolic compounds react on carbon surfaces. The reaction rate is a strong function of temperature. Regeneration of carbons by leaching with acetone recovered at least as much phenol as did regeneration with other solvents or with displacers. The physiochemical properties of adsorbents influences irreversible uptakes. Sorbates differed markedly in their tendencies to undergo irreversible adsorption. 64 refs., 47 figs., 32 tabs

  12. Social desirability scales as indicators of self-enhancement and impression management.

    Science.gov (United States)

    Parmač Kovačić, Maja; Galić, Zvonimir; Jerneić, Željko

    2014-01-01

    This article presents 2 studies testing Paulhus's (2002) assumption that unconscious self-enhancement and conscious impression management represent separate processes of socially desirable responding (SDR) that can be observed within 2 content domains (egoistic and moralistic bias). In Study 1, we devised egoistic and moralistic SDR scales intended to measure self-enhancement in honest responding and impression management under demands for positive self-presentation. In Study 2, we correlated scores on these scales with external indicators of self-enhancement and impression management. In honest responding, both SDR scales most strongly correlated with self-enhancement indicators, whereas under demands for positive self-presentation they correlated more strongly with external measures of impression management.

  13. Management of excessive movable tissue: a modified impression technique.

    Science.gov (United States)

    Shum, Michael H C; Pow, Edmond H N

    2014-08-01

    Excessive movable tissue is a challenge in complete denture prosthetics. A modified impression technique is presented with polyvinyl siloxane impression material and a custom tray with relief areas and perforations in the area of the excessive movable tissue. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Facial first impressions and partner preference models: Comparable or distinct underlying structures?

    Science.gov (United States)

    South Palomares, Jennifer K; Sutherland, Clare A M; Young, Andrew W

    2017-12-17

    Given the frequency of relationships nowadays initiated online, where impressions from face photographs may influence relationship initiation, it is important to understand how facial first impressions might be used in such contexts. We therefore examined the applicability of a leading model of verbally expressed partner preferences to impressions derived from real face images and investigated how the factor structure of first impressions based on potential partner preference-related traits might relate to a more general model of facial first impressions. Participants rated 1,000 everyday face photographs on 12 traits selected to represent (Fletcher, et al. 1999, Journal of Personality and Social Psychology, 76, 72) verbal model of partner preferences. Facial trait judgements showed an underlying structure that largely paralleled the tripartite structure of Fletcher et al.'s verbal preference model, regardless of either face gender or participant gender. Furthermore, there was close correspondence between the verbal partner preference model and a more general tripartite model of facial first impressions derived from a different literature (Sutherland et al., 2013, Cognition, 127, 105), suggesting an underlying correspondence between verbal conceptual models of romantic preferences and more general models of facial first impressions. © 2017 The British Psychological Society.

  15. Port contact systems for irreversible thermodynamical systems

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; Schaft, A.J. van der

    2005-01-01

    In this paper we propose a definition of control contact systems, generalizing input-output Hamiltonian systems, to cope with models arising from irreversible Thermodynamics. We exhibit a particular subclass of these systems, called conservative, that leaves invariant some Legendre submanifold (the

  16. Classical many-body theory with retarded interactions: Dynamical irreversibility and determinism without probabilities

    Energy Technology Data Exchange (ETDEWEB)

    Zakharov, A.Yu., E-mail: Anatoly.Zakharov@novsu.ru; Zakharov, M.A., E-mail: ma_zakharov@list.ru

    2016-01-28

    The exact equations of motion for microscopic density of classical many-body system with account of inter-particle retarded interactions is derived. It is shown that interactions retardation leads to irreversible behavior of many-body systems. - Highlights: • A new form of equation of motion of classical many-body system is proposed. • Interactions retardation as one of the mechanisms of many-body system irreversibility. • Irreversibility and determinism without probabilities. • The possible way to microscopic foundation of thermodynamics.

  17. β-characterization by irreversibility analysis: A thermoeconomic diagnosis method

    International Nuclear Information System (INIS)

    Zaleta-Aguilar, Alejandro; Olivares-Arriaga, Abraham; Cano-Andrade, Sergio; Rodriguez-Alejandro, David A.

    2016-01-01

    This paper presents a reconciliation methodology for the diagnosis of energy systems. The methodology is based on the characterization of irreversibilities in the components of an energy system. These irreversibilities can be attributed to malfunctions or dysfunctions. The characterization of irreversibilities as presented here makes possible to reconcile the Actual Operating Condition (AOC) versus the Reference Operating Condition (ROC) of the energy system in a real-time manner. The diagnosis methodology introduces a parameter β, which represents the total exergy or useful work of a component in terms of its inlet and output streams at either design (full-load) or off-design (partial-load) conditions. The methodology is applied to the diagnosis of an actual Natural Gas Combined Cycle (NGCC) power plant. Data for the model is obtained directly from the plant by monitoring its performance at every time; thus, a real-time thermodynamic diagnosis for the system is obtained. Results show that the methodology presented here is able to detect and quantify the deviations on the performance of the NGCC power plant during its real-time operation. Based on the detection and quantification of these deviations, the user is able to make recommendations to schedule maintenance on the components where the irreversibilities are present. - Highlights: • A new methodology for thermoeconomic diagnosis of energy systems is presented. • A parameter β is defined for characterization of the components of an energy system. • The β characterization methodology is tested in a real 420 MW NGCC power plant. • Results show that the complexity of a diagnosis analysis is reduced substantially.

  18. Variability of Irreversible Poleward Transport in the Lower Stratosphere

    Science.gov (United States)

    Olsen, Mark; Douglass, Anne; Newman, Paul; Nash, Eric; Witte, Jacquelyn; Ziemke, Jerry

    2011-01-01

    The ascent and descent of the Brewer-Dobson circulation plays a large role in determining the distributions of many constituents in the extratropical lower stratosphere. However, relatively fast, quasi-horizontal transport out of the tropics and polar regions also significantly contribute to determining these distributions. The tropical tape recorder signal assures that there must be outflow from the tropics into the extratropical lower stratosphere. The phase of the quasi-biennial oscillation (QBO) and state of the polar vortex are known to modulate the transport from the tropical and polar regions, respectively. In this study we examine multiple years of ozone distributions in the extratropical lower stratosphere observed by the Aura Microwave Limb Sounder (MLS) and the Aura High Resolution Dynamic Limb Sounder (HIRDLS). The distributions are compared with analyses of irreversible, meridional isentropic transport. We show that there is considerable year-to-year seasonal variability in the amount of irreversible transport from the tropics, which is related to both the phase of the QBO and the state of the polar vortex. The reversibility of the transport is consistent with the number of observed breaking waves. The variability of the atmospheric index of refraction in the lower stratosphere is shown to be significantly correlated with the wave breaking and amount of irreversible transport. Finally, we will show that the seasonal extratropical stratosphere to troposphere transport of ozone can be substantially modulated by the amount of irreversible meridional transport in the lower stratosphere and we investigate how observable these differences are in data of tropospheric ozone.

  19. Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions

    OpenAIRE

    Ghahremanloo, Ahmad; Seifi, Mahdieh; Ghanbarzade, Jalil; Abrisham, Seyyed Mohammad; Javan, Rashid Abdolah

    2017-01-01

    Objectives: The aim of this study was to compare the accuracy of dental implant impressions obtained by a combination of different impression techniques and viscosities of polyvinyl siloxane (PVS).Materials and Methods: Four parallel fixtures were placed between mental foramina in a master model of lower dental arch. Three different viscosities (putty/light body, medium body/light body, and monophase: heavy body) and direct and indirect techniques (six groups) were used, and seven impressions...

  20. Effects of Inconsistent Behaviors on Person Impressions: A Multidimensional Study.

    Science.gov (United States)

    Vonk, Roos

    1995-01-01

    Examined effects of unexpected behavioral information on person impressions. Inconsistency was manipulated with respect to Implicit Personality Theory. Found that behaviors with inconsistent evaluation implications did not affect impressions and that effects of inconsistent information depended on dimension of contrast, valence of initial…

  1. 21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.

    Science.gov (United States)

    2010-04-01

    ... of sensor and a computer with software. (b) Classification. Class II (Special Controls). The device... entitled “Class II Special Controls Guidance Document: Optical Impression Systems for Computer Assisted.../CAM. (a) Identification. An optical impression system for computer assisted design and manufacturing...

  2. Accuracy of different impression materials in parallel and nonparallel implants

    Directory of Open Access Journals (Sweden)

    Mahroo Vojdani

    2015-01-01

    Conclusion: Within the limitations of this study, in parallel conditions, the type of impression material cannot affect the accuracy of the implant impressions; however, in nonparallel conditions, polyvinyl siloxane is shown to be a better choice, followed by vinyl siloxanether and polyether respectively.

  3. Three-dimensional accuracy of plastic transfer impression copings for three implant systems.

    Science.gov (United States)

    Teo, Juin Wei; Tan, Keson B; Nicholls, Jack I; Wong, Keng Mun; Uy, Joanne

    2014-01-01

    The purpose of this study was to compare the three-dimensional accuracy of indirect plastic impression copings and direct implant-level impression copings from three implant systems (Nobel Biocare [NB], Biomet 3i [3i], and Straumann [STR]) at three interimplant buccolingual angulations (0, 8, and 15 degrees). Two-implant master models were used to simulate a three-unit implant fixed partial denture. Test models were made from Impregum impressions using direct implant-level impression copings (DR). Abutments were then connected to the master models for impressions using the plastic impression copings (INDR) at three different angulations for a total of 18 test groups (n = 5 in each group). A coordinate measuring machine was used to measure linear distortions, three-dimensional (3D) distortions, angular distortions, and absolute angular distortions between the master and test models. Three-way analysis of variance showed that the implant system had a significant effect on 3D distortions and absolute angular distortions in the x- and y-axes. Interimplant angulation had a significant effect on 3D distortions and absolute angular distortions in the y-axis. Impression technique had a significant effect on absolute angular distortions in the y-axis. With DR, the NB and 3i systems were not significantly different. With INDR, 3i appeared to have less distortion than the other systems. Interimplant angulations did not significantly affect the accuracy of NBDR, 3iINDR, and STRINDR. The accuracy of INDR and DR was comparable at all interimplant angulations for 3i and STR. For NB, INDR was comparable to DR at 0 and 8 degrees but was less accurate at 15 degrees. Three-dimensional accuracy of implant impressions varied with implant system, interimplant angulation, and impression technique.

  4. Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis.

    Science.gov (United States)

    Chochlidakis, Konstantinos M; Papaspyridakos, Panos; Geminiani, Alessandro; Chen, Chun-Jung; Feng, I Jung; Ercoli, Carlo

    2016-08-01

    Limited evidence is available for the marginal and internal fit of fixed dental restorations fabricated with digital impressions compared with those fabricated with conventional impressions. The purpose of this systematic review was to compare marginal and internal fit of fixed dental restorations fabricated with digital techniques to those fabricated using conventional impression techniques and to determine the effect of different variables on the accuracy of fit. Medline, Cochrane, and EMBASE databases were electronically searched and enriched by hand searches. Studies evaluating the fit of fixed dental restorations fabricated with digital and conventional impression techniques were identified. Pooled data were statistically analyzed, and factors affecting the accuracy of fit were identified, and their impact on accuracy of fit outcomes were assessed. Dental restorations fabricated with digital impression techniques exhibited similar marginal misfit to those fabricated with conventional impression techniques (P>.05). Both marginal and internal discrepancies were greater for stone die casts, whereas digital dies produced restorations with the smallest discrepancies (Pdigital impression was used to generate stereolithographic (SLA)/polyurethane dies, misfit values were intermediate. The fabrication technique, the type of restoration, and the impression material had no effect on misfit values (P>.05), whereas die and restoration materials were statistically associated (Pdigital impression technique provided better marginal and internal fit of fixed restorations than conventional techniques did. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Accuracy of different abutment level impression techniques in All-On-4 dental implants

    Directory of Open Access Journals (Sweden)

    Marzieh Alikhasi

    2012-01-01

    Full Text Available Background and Aims: Passive fit of prosthetic frameworks is a major concern in implant dentistry. Impression technique is one of the several variables that may affect the outcome of dental implants. The purpose of this study was to compare the three dimensional accuracy of direct and indirect abutment level implant impressions ofALL-ON-4 treatment plan.Materials and Methods: A reference acrylic resin model with four Branemark fixtures was made according to All-On-4 treatment plan. Multiunit abutments were screwed into the fixtures and two special trays were made for direct and indirect impression techniques. Ten direct and ten indirect impression techniques with respective impression transfers were made. Impressions were poured with stone and the positional accuracy of the abutment analogues in each dimension of x, y, and z axes and also angular displacement (Δθ were evaluated using a Coordinate Measuring Machine (CMM. Data were analyzed using T- test.Results: The results showed that direct impression technique was significantly more accurate than indirect technique (P<0.001.Conclusion: The results showed that the accuracy of direct impression technique was significantly more than that of indirect technique in Δθ and Δr coordinate and also Δx, Δy, Δz.

  6. Quantum thermodynamics: Microscopic foundations of entropy and of entropy generation by irreversibility

    Directory of Open Access Journals (Sweden)

    Beretta, Gian Paolo

    2008-02-01

    Full Text Available What is the physical significance of entropy? What is the physical origin of irreversibility? Do entropy and irreversibility exist only for complex and macroscopic systems? Most physicists still accept and teach that the rationalization of these fundamental questions is given by Statistical Mechanics. Indeed, for everyday laboratory physics, the mathematical formalism of Statistical Mechanics (canonical and grand-canonical, Boltzmann, Bose-Einstein and Fermi-Dirac distributions allows a successful description of the thermodynamic equilibrium properties of matter, including entropy values. However, as already recognized by Schrodinger in 1936, Statistical Mechanics is impaired by conceptual ambiguities and logical inconsistencies, both in its explanation of the meaning of entropy and in its implications on the concept of state of a system. An alternative theory has been developed by Gyftopoulos, Hatsopoulos and the present author to eliminate these stumbling conceptual blocks while maintaining the mathematical formalism so successful in applications. To resolve both the problem of the meaning of entropy and that of the origin of irreversibility we have built entropy and irreversibility into the laws of microscopic physics. The result is a theory, that we call Quantum Thermodynamics, that has all the necessary features to combine Mechanics and Thermodynamics uniting all the successful results of both theories, eliminating the logical inconsistencies of Statistical Mechanics and the paradoxes on irreversibility, and providing an entirely new perspective on the microscopic origin of irreversibility, nonlinearity (therefore including chaotic behavior and maximal-entropy-generation nonequilibrium dynamics. In this paper we discuss the background and formalism of Quantum Thermodynamics including its nonlinear equation of motion and the main general results. Our objective is to show in a not-too-technical manner that this theory provides indeed a

  7. A new approach to irreversibility in deep inelastic collisions

    International Nuclear Information System (INIS)

    Nemes, M.C.

    1982-01-01

    We use concepts of statistical mechanics to discuss the irreversible character of the experimental data in deep inelastic collisions. A definition of irreversibility proposed by Ruch permits a unified overview on current theories which describe these reactions. An information theoretical analysis of the data leads to a Fokker-Planck equation for the collective variables (excitation energy, charge and mass). The concept of mixing distance can serve as a quantitative measure to characterize the 'approach to equilibrium'. We apply it to the brownian motion as an illustration and also to the phenomenological analysis of deep inelastic scattering data with interesting results. (orig.)

  8. Digitization of simulated clinical dental impressions: virtual three-dimensional analysis of exactness.

    Science.gov (United States)

    Persson, Anna S K; Odén, Agneta; Andersson, Matts; Sandborgh-Englund, Gunilla

    2009-07-01

    To compare the exactness of simulated clinical impressions and stone replicas of crown preparations, using digitization and virtual three-dimensional analysis. Three master dies (mandibular incisor, canine and molar) were prepared for full crowns, mounted in full dental arches in a plane line articulator. Eight impressions were taken using an experimental monophase vinyl polysiloxane-based material. Stone replicas were poured in type IV stone (Vel-Mix Stone; Kerr). The master dies and the stone replicas were digitized in a touch-probe scanner (Procera) Forte; Nobel Biocare AB) and the impressions in a laser scanner (D250, 3Shape A/S), to create virtual models. The resulting point-clouds from the digitization of the master dies were used as CAD-Reference-Models (CRM). Discrepancies between the points in the pointclouds and the corresponding CRM were measured by a matching-software (CopyCAD 6.504 SP2; Delcam Plc). The distribution of the discrepancies was analyzed and depicted on color-difference maps. The discrepancies of the digitized impressions and the stone replicas compared to the CRM were of similar size with a mean+/-SD within 40microm, with the exception of two of the digitized molar impressions. The precision of the digitized impressions and stone replicas did not differ significantly (F=4.2; p=0.053). However, the shape affected the digitization (F=5.4; p=0.013) and the interaction effect of shape and digitization source (impression or stone replica) was pronounced (F=28; pimpressions varied with shape. Both impressions and stone replicas can be digitized repeatedly with a high reliability.

  9. At face value: Visual antecedents of impression formation in servicescapes

    NARCIS (Netherlands)

    Verhoeven, J.W.M.; van Rompay, Thomas Johannes Lucas; Pruyn, Adriaan T.H.; Mc.Gill, Ann L.; Shavitt, Sharon

    2009-01-01

    Consumers may base employee impressions on physical appearance and displayed personal objects. In a scenario experiment, using photos of a physician and a 360-degree panorama of his consultation room, we examined the effects of appearance and tangibles on impression formation. Study 1 shows that

  10. Development and Psychometric Evaluation of a Clinical Global Impression for Schizoaffective Disorder Scale

    OpenAIRE

    Allen, Michael H; Daniel, David G; Revicki, Dennis A; Canuso, Carla M; Turkoz, Ibrahim; Fu, Dong-Jing; Alphs, Larry; Ishak, K. Jack; Bartko, John J; Lindenmayer, Jean-Pierre

    2012-01-01

    Objective: The Clinical Global Impression for Schizoaffective Disorder scale is a new rating scale adapted from the Clinical Global Impression scale for use in patients with schizoaffective disorder. The psychometric characteristics of the Clinical Global Impression for Schizoaffective Disorder are described.

  11. Evaluation of outgassing, tear strength, and detail reproduction in alginate substitute materials.

    Science.gov (United States)

    Baxter, R T; Lawson, N C; Cakir, D; Beck, P; Ramp, L C; Burgess, J O

    2012-01-01

    To compare three alginate substitute materials to an alginate impression material for cast surface porosity (outgassing), tear strength, and detail reproduction. Detail reproduction tests were performed following American National Standards Institute/American Dental Association (ANSI/ADA) Specification No. 19. To measure tear strength, 12 samples of each material were made using a split mold, placed in a water bath until testing, and loaded in tension until failure at a rate of 500 mm/min using a universal testing machine. For cast surface porosity testing, five impressions of a Teflon mold with each material were placed in a water bath (37.8°C) for the in-mouth setting time and poured with vacuum-mixed Silky Rock die stone at 5, 10, 30, and 60 minutes from the start of mixing. The gypsum samples were analyzed with a digital microscope for surface porosity indicative of hydrogen gas release by comparing the surface obtained at each interval with four casts representing no, little, some, and significant porosity. Data analysis was performed using parametric and Kruskal-Wallis analysis of variance (ANOVA), Tukey/Kramer post-hoc tests (α=0.05), and individual Mann-Whitney U tests (α=0.0167). All alginate substitute materials passed the detail reproduction test. Tear strength of the alginate substitute materials was significantly better than alginate and formed three statistically different groups: AlgiNot had the lowest tear strength, Algin-X Ultra had the highest tear strength, and Position Penta Quick had intermediate tear strength. Significant variation in outgassing existed between materials and pouring times (palginate substitute materials exhibited the least outgassing and cast porosity 60 minutes after mixing. Detail reproduction and tear strength of alginate substitute materials were superior to traditional alginate. The outgassing effect was minimal for most materials tested. Alginate substitute materials are superior replacements for irreversible

  12. Assessment of Influence of Contact Time between Alginate and Type III Dental Stone on Properties of Cast Model: An in vitro Study.

    Science.gov (United States)

    Dev, Shruti; Kar, Aswini K; Garhnayak, Mirna; Garhnayak, Lokanath; Dhal, Angurbala

    2017-10-01

    Alginate is a versatile, irreversible hydrocolloid impression material, which is cost-effective and forms an essential component in dental practice. For elevating the hardness of the cast models, hardeners are combined with stone. Hence, we planned the present study to evaluate the impact of altering the time of contact between alginate and stone after various interim periods. The present study included the assessment of impact of time of contact between alginate and stone by the construction of 90 casts using a cylinder model. Two bisecting lines were marked and were named as y and y'. These lines were used for testing the dimensional stability. Using chemically cured acrylic resin, the construction of ten special trays was done. All the impression casts were randomly divided into two study groups, with 45 casts in each group-group I: control group, casts were removed after 60 minutes; group II: study group, casts were removed after 9 hours. A digital caliper was used for measuring the dimensional stability of the cast. All the data were collected and analyzed. In the specimens of the control group (group I) and the study group (group II), the mean dimensions from y to y' were found to be 17.54 and 17.95 respectively. The mean reading of hardness in the control group and study group was found to be 0.59 and 0.20 respectively. In groups I and II, the number of specimens showing clarity of two lines (X and X") was 0 and 5 respectively. There was no change in the dimensional stability of the dental stone model when the contact time was increased. Within certain limits, the contact time between alginate and stone can be altered without significantly altering the properties of the cast.

  13. Strategies for managing impressions of racial identity in the workplace.

    Science.gov (United States)

    Roberts, Laura Morgan; Cha, Sandra E; Kim, Sung Soo

    2014-10-01

    This article deepens understanding of the workplace experiences of racial minorities by investigating racial identity-based impression management (RIM) by Asian American journalists. Racial centrality, directly or indirectly, predicted the use of 4 RIM strategies (avoidance, enhancement, affiliation, and racial humor). Professional centrality also predicted strategy use, which was related to life satisfaction and perceived career success. By shedding light on proactive strategies that individuals use to influence colleagues' impressions of their racial identity, we contribute to research on diversity in organizations, impression management, and racial identity. (PsycINFO Database Record (c) 2014 APA, all rights reserved).

  14. A Comparison of implant impression precision: Different materials and techniques

    Science.gov (United States)

    Tabesh, Mahtab; Alikhasi, Marzieh

    2018-01-01

    Background Precision of implant impressions is a prerequisite for long-term success of implant supported prostheses. Impression materials and impression techniques are two important factors that impression precision relies on. Material and Methods A model of edentulous maxilla containing four implants inserted by All-on-4 guide was constructed. Seventy two impressions using polyether (PE), polyvinyl siloxane (PVS), and vinyl siloxanether (VSE) materials with direct and indirect techniques were made (n=12). Coordinates of implants in casts were measured using coordinate measuring machine (CMM). Data were analyzed with ANOVA; t-test and Tukey test were used for post hoc. Results With two-way ANOVA, mean values of linear displacements of implants were significantly different among materials and techniques. One-way ANOVA and Tukey showed significant difference between PE and VSE (P=0.019), PE and PVS (P=0.002) in direct technique, and between PVS and PE (Pimpression of implants, PE is recommended for direct technique while PE and VSE are recommended for indirect technique. Recommended technique for VSE is either direct or indirect; and for PE and PVS is direct. Key words:Polyvinyl siloxane, polyether, vinyl siloxanether, direct technique, indirect technique, All-on-4, coordinate measuring machine. PMID:29670733

  15. Dinosaur Impressions

    Science.gov (United States)

    Taquet, Philippe

    1998-09-01

    Perhaps you are a paleontologist or have always wondered what it is like to be one. Or you are fascinated by fossils and like to read about the origins and natural history of dinosaurs. Or maybe you are an avid traveler and reader of travelogues. If you are any of these things, then this book is for you. Originally published in 1994 in French, Dinosaur Impressions is the engaging account of thirty years of travel and paleontological exploration by Philippe Taquet, one of the world's most noted paleontologists. Dr. Taquet takes the reader on a surprisingly far-flung tour ranging from the Provence countryside to the Niger desert, from the Brazilian bush to the Mongolian Steppes, and from the Laos jungle to the Moroccan mountains in search of dinosaur bones and what they have to tell us about a vanished world. With wry humor and lively anecdotes, Dr. Taquet retraces the history of paleontological research, along the way discussing the latest theories of dinosaur existence and extinction. Elegantly translated by Kevin Padian, Dinosaur Impressions provides a unique, thoughtful perspective not often encountered in American- and English-language works. This insightful, first-hand account of an exceptional career is also a travelogue par excellence that will enthrall enthusiasts and general readers alike. Philippe Taquet is the Director of the National Museum of Natural History in Paris and is a member of the French Academy of Sciences. Kevin Padian is a professor in the Department of Integrative Biology and Curator of the Museum of Paleontology at the University of California, Berkeley. He is also the editor of The Beginning of the Age of Dinosaurs (Cambridge, 1986) and The Encyclopedia of Dinosaurs (1997).

  16. SRIM Scheme: An Impression-Management Scheme for Privacy-Aware Photo-Sharing Users

    Directory of Open Access Journals (Sweden)

    Fenghua Li

    2018-02-01

    Full Text Available With the development of online social networks (OSNs and modern smartphones, sharing photos with friends has become one of the most popular social activities. Since people usually prefer to give others a positive impression, impression management during photo sharing is becoming increasingly important. However, most of the existing privacy-aware solutions have two main drawbacks: ① Users must decide manually whether to share each photo with others or not, in order to build the desired impression; and ② users run a high risk of leaking sensitive relational information in group photos during photo sharing, such as their position as part of a couple, or their sexual identity. In this paper, we propose a social relation impression-management (SRIM scheme to protect relational privacy and to automatically recommend an appropriate photo-sharing policy to users. To be more specific, we have designed a lightweight face-distance measurement that calculates the distances between users’ faces within group photos by relying on photo metadata and face-detection results. These distances are then transformed into relations using proxemics. Furthermore, we propose a relation impression evaluation algorithm to evaluate and manage relational impressions. We developed a prototype and employed 21 volunteers to verify the functionalities of the SRIM scheme. The evaluation results show the effectiveness and efficiency of our proposed scheme. Keywords: Impression management, Relational privacy, Photo sharing, Policy recommendation, Proxemics

  17. Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

    Science.gov (United States)

    Ebadian, Behnaz; Rismanchian, Mansor; Dastgheib, Badrosadat; Bajoghli, Farshad

    2015-01-01

    Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxillary model perpendicular to the horizontal plane in maxillary lateral incisors, right canine and left first premolar areas. Three impression techniques including open tray, closed tray using ball top screw abutments and closed tray using short impression copings and two impression materials (polyether and polyvinyl siloxane) were evaluated (n = 60). The changes in distances between implant analogues in mediolateral (x) and anteroposterior (y) directions and analogue angles in x/z and y/z directions in the horizontal plane on the definitive casts were measured by coordinate measuring machine. The data were analyzed by multivariate two-way analysis of variance and one sample t-test (α = 0.05). No statistical significant differences were observed between different impression techniques and materials. However, deviation and distortion of definitive casts had a significant difference with the master model when short impression copings and polyvinyl siloxane impression material were used (P impression materials (P impression techniques; however, less distortion and deviation were observed in the open tray technique. In the closed tray impression technique, ball top screw was more accurate than short impression copings.

  18. Microbiological evaluation of ultrasonic nebulization for disinfecting dental impressions.

    Science.gov (United States)

    Mendonca, Marcio Jose; Rafael, Renata Santos; Camilotti, Veridiana; Menolli, Rafael Andrade; Sicoli, Eliseu Augusto; Teixeira, Nancielli; Sinhoreti, Mario Alexandre Coelho

    2013-07-01

    Disinfecting dental impressions is necessary to decrease the risk of cross-contamination in dental offices. Ultrasonic nebulization has been mentioned as a microbicidal technique that can be used to disinfect contaminated dental impressions. This study compared the microbicidal effect of 2% glutaraldehyde and 0.2% peracetic acid for the disinfection of dental impressions made with vinyl polysiloxane, using 2 disinfection methods: immersion and ultrasonic nebulization. Bactericial efficacy was examined using Staphylococcus aureus and Bacillus atrophaeus as indicators. Thirty impressions were obtained and distributed randomly in 5 groups (n = 6). Group 1 was immersed in 2% glutaraldehyde immersion for 10 minutes, Group 2 was immersed in 0.2% peracetic acid for 10 minutes, Group 3 underwent ultrasonic nebulization for 10 minutes in 2% glutaraldehyde solution, Group 4 underwent ultrasonic nebulization for 10 minutes in 0.2% peracetic acid solution, and Group 5 was a control group that received no disinfectant. Both solutions experienced a 100% reduction in microorganisms following ultrasonic nebulization, as did peracetic acid following immersion; however, immersion in glutaraldehyde demonstrated lower values of reduction in B atrophaeus group, with a statistically significant difference compared with the other experimental groups.

  19. Does aging impair first impression accuracy? Differentiating emotion recognition from complex social inferences.

    Science.gov (United States)

    Krendl, Anne C; Rule, Nicholas O; Ambady, Nalini

    2014-09-01

    Young adults can be surprisingly accurate at making inferences about people from their faces. Although these first impressions have important consequences for both the perceiver and the target, it remains an open question whether first impression accuracy is preserved with age. Specifically, could age differences in impressions toward others stem from age-related deficits in accurately detecting complex social cues? Research on aging and impression formation suggests that young and older adults show relative consensus in their first impressions, but it is unknown whether they differ in accuracy. It has been widely shown that aging disrupts emotion recognition accuracy, and that these impairments may predict deficits in other social judgments, such as detecting deceit. However, it is unclear whether general impression formation accuracy (e.g., emotion recognition accuracy, detecting complex social cues) relies on similar or distinct mechanisms. It is important to examine this question to evaluate how, if at all, aging might affect overall accuracy. Here, we examined whether aging impaired first impression accuracy in predicting real-world outcomes and categorizing social group membership. Specifically, we studied whether emotion recognition accuracy and age-related cognitive decline (which has been implicated in exacerbating deficits in emotion recognition) predict first impression accuracy. Our results revealed that emotion recognition accuracy did not predict first impression accuracy, nor did age-related cognitive decline impair it. These findings suggest that domains of social perception outside of emotion recognition may rely on mechanisms that are relatively unimpaired by aging. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  20. Turn Management or Impression Management?

    NARCIS (Netherlands)

    ter Maat, Mark; Heylen, Dirk K.J.; Ruttkay, Z.M.; Kipp, M.; Nijholt, Antinus; Vilhjálmsson, H.H.

    2009-01-01

    We look at how some basic choices in the management of turns influence the impression that people get from an agent. We look at scales concerning personality, emotion and interpersonal stance. We do this by a person perception study, or rather an agent perception study, using simulated conversations

  1. Selling oneself: construct and criterion-related validity of impression management in structured interviews

    NARCIS (Netherlands)

    Kleinmann, M.; Klehe, U.-C.

    2010-01-01

    Interviewee impression management has been a long-standing concern in the interview literature. Yet recent insights into the impact of impression management on interviewee performance in structured interviews suggest that interviewee impression management may be more than just a source of bias and a

  2. Effect of addition of different hydrocolloids on pasting, thermal, and rheological properties of cassava starch

    Directory of Open Access Journals (Sweden)

    Tatiana Dias Leite

    2012-09-01

    Full Text Available Starches and gums are hydrocolloids frequently used in food systems to provide proper texture, moisture, and water mobility. Starch-gum interaction in food systems can change the starch granule swelling and its gelatinization and rheological properties. In this study, the effect of the addition of xanthan gum (XG, sodium carboxymethyl cellulose (SCMC, and carrageenan (CAR at the concentrations of the 0.15, 0.25, 0.35 and 0.45% (w/v on the pasting, thermal, and rheological properties of cassava starch was studied. The swelling power (SP and the scanning electron microscopy (SEM of the starch gels were also evaluated. The results obtained showed that xanthan gum (XG had a strong interaction with the cassava starch penetrating between starch granules causing increase in pasting viscosities, SP, storage and loss (G', and G", respectively modulus and reduction in the setback of the starch; sodium carboxymethyl cellulose (SCMC greatly increased the pasting viscosities, the SP, and the storage and loss (G', and G", respectively modulus of the starch-mixtures, mainly due to its greater capacity to hold water and not due to the interaction with cassava starch. Carrageenan (CAR did not change any of the starch properties since there was no interaction between this gum and cassava starch at the concentrations used.

  3. Extremum principles for irreversible processes

    International Nuclear Information System (INIS)

    Hillert, M.; Agren, J.

    2006-01-01

    Hamilton's extremum principle is a powerful mathematical tool in classical mechanics. Onsager's extremum principle may play a similar role in irreversible thermodynamics and may also become a valuable tool. His principle may formally be regarded as a principle of maximum rate of entropy production but does not have a clear physical interpretation. Prigogine's principle of minimum rate of entropy production has a physical interpretation when it applies, but is not strictly valid except for a very special case

  4. Observing and Understanding Children's Social Interactions. An Impression Management Perspective.

    Science.gov (United States)

    Hatch, J. Amos

    1994-01-01

    Describes ways of observing and interpreting children's peer social behavior based on the impression management perspective, which focuses on the social construction of a child's individual self-concept. Suggests that teachers and caregivers can use impression management strategies to observe and promote prosocial development in young children.…

  5. Impression Management by Association: Construction and Validation of a Scale.

    Science.gov (United States)

    Andrews, Martha C.; Kacmar, K. Michele

    2001-01-01

    Impression management (managing associations with others to create a favorable impression) using such tactics as boasting, blurring, blaring, and burying was examined using factor and validity analyses of data from the Image Management by Association Scale. The scale satisfactorily represented the four tactics, although burying and blaring needed…

  6. Evaluation of digital model accuracy and time-dependent deformation of alginate impressions.

    Science.gov (United States)

    Cesur, M G; Omurlu, I K; Ozer, T

    2017-09-01

    The aim of this study was to evaluate the accuracy of digital models produced with the three-dimensional dental scanner, and to test the dimensional stability of alginate impressions for durations of immediately (T0), 1 day (T1), and 2 days (T2). A total of sixty impressions were taken from a master model with an alginate, and were poured into plaster models in three different storage periods. Twenty impressions were directly scanned (negative digital models), after which plaster models were poured and scanned (positive digital models) immediately. The remaining 40 impressions were poured after 1 and 2 days. In total, 9 points and 11 linear measurements were used to analyze the plaster models, and negative and positive digital models. Time-dependent deformation of the alginate impressions and the accuracy of the conventional plaster models and digital models were evaluated separately. Plaster models, negative and positive digital models showed significant differences in nearly all measurements at T (0), T (1), and T (2) times (P 0.05), but they demonstrated statistically significant differences at T (2) time (P impressions is practicable method for orthodontists.

  7. Effects of disinfection of combined agar/alginate impressions on the dimensional accuracy of stone casts.

    Science.gov (United States)

    Hiraguchi, Hisako; Nakagawa, Hisami; Kaketani, Masahiro; Hirose, Hideharu; Nishiyama, Minoru

    2007-05-01

    This study investigated the effects of disinfection of combined agar/alginate impressions on the dimensional accuracy of resultant stone casts. Impressions of a master cast designed to simulate an abutment tooth were prepared by combining each of two brands of cartridge-form agar impression materials with an alginate impression material. The impressions were immersed in 1% sodium hypochlorite for 10 minutes or 2% glutaraldehyde for 30 minutes. The remaining impressions were sprayed with these two disinfectants and then stored in sealed bags for 10, 30, 60, and 120 minutes. Stone casts obtained from the non-disinfected impressions were also prepared as control. Changes in diameter of the stone casts were then measured. Results indicated that storage for 10 minutes after spraying with 1% sodium hypochlorite was an appropriate disinfection method for combined agar/alginate impressions, as well as immersion in 1% sodium hypochlorite for 10 minutes.

  8. EFECTO REOLÓGICO DE HIDROCOLOIDES SOBRE LA SALMUERA DE MARINADO DE CARNE BOVINA EFEITO REOLÓGICO DE HIDROCOLOIDES NA SALMOURA DE MARINADO DE CARNE BOVINA EFFECT OF HYDROCOLLOIDS ON RHEOLOGICAL BRINE MARINATED MEAT

    Directory of Open Access Journals (Sweden)

    YOMAIRA TAPASCO Z

    2011-12-01

    carragena. Esta mezla foi utilizada na salmoura em très concentraçóes de 0,5%, 1,0% e 1,5%. A salmoura foi usado para marinar carne do músculo semitendinoso. As amostras foram resfriadas durante 3 dias. As perdas de peso foram determinadas antes e após o cozimento a 80°C de temperatura interna e fez a análise do perfil de textura. Os resultados indicaram que a melhor concentraçáo de hidrocolóides foi observada no tratamento com 1,5%. Só foi encontrada diferença significativa (pIn some countries the practice of marinated meat has been turned into routine practice, however losses from cooking are considerable. The objective of this research was to assess the performance of three hydrocolloid thixotropic thickening agent in the brine used for marinating meat. Hydrocolloids used were: xanthan gum, guar gum and carrageenan I, was initially proposed a mix design to choose the best one. He was then evaluated the effect on the thixotropy presented the optimal mixture of hydrocolloids contained in a standard brine marinated red meat. The optimal mix of hydrocolloids found was of 87% and 13% xanthan gum and carrageenan used in the brine at three concentrations 0,5%, 1.0% and 1,5%. This brine was used to marinate meat samples bovine semitendinosus muscle. Treatment samples were chilled in cava for 3 days. Weight losses were determined before and after cooking at 80°C internal temperature and made the texture profile analysis. The results indicated that the best concentration of hydrocolloids for the treatments was 1,5%. Was established only significant difference (p<0,05 for moisture loss and attributes gomosidad and chewiness.

  9. Use of antioxidants substances to protect the hydrocolloids carrageenan, agaran and alginates used in food industry when exposed to radiation

    International Nuclear Information System (INIS)

    Aliste, Antonio Joao

    2006-01-01

    Carrageenan, agaran e alginates are hydrocolloids largely employed in every kind of food products as stabilizing agent and viscosity builder. The human body does not absorb them, so they do not introduce extra calories in the diet. Irradiation is presented as an important alternative method in food preservation because do not induce temperature increase being of good efficiency in cold food ingredients decontamination. In this work aqueous solutions of carrageenan, agar e sodium alginate were gamma irradiated (0-10 kGy) in presence of ascorbic acid, roselle (Hibiscus sabdariffa L.) extract and soy isoflavone. Edible polysaccharide solutions showed to be suitable systems for the evaluation of ionizing radiation effects as they presented a singular radiosensitivity through viscosity changes. The results obtained showed that in general the antioxidants employed had a radioprotective action that can be of importance in the future commercial applications of food irradiation. (author)

  10. Irreversible performance of a quantum harmonic heat engine

    Science.gov (United States)

    Rezek, Yair; Kosloff, Ronnie

    2006-05-01

    The unavoidable irreversible loss of power in a heat engine is found to be of quantum origin. Following thermodynamic tradition, a model quantum heat engine operating in an Otto cycle is analysed, where the working medium is composed of an ensemble of harmonic oscillators and changes in volume correspond to changes in the curvature of the potential well. Equations of motion for quantum observables are derived for the complete cycle of operation. These observables are sufficient to determine the state of the system and with it all thermodynamical variables. Once the external controls are set, the engine settles to a limit cycle. Conditions for optimal work, power and entropy production are derived. At high temperatures and quasistatic operating conditions, the efficiency at maximum power coincides with the endoreversible result \\eta_q=1-\\sqrt{{T_c}/{T_h}} . The optimal compression ratio varies from {\\cal C} =\\sqrt{T_h/T_c} in the quasistatic limit where the irreversibility is dominated by heat conductance to {\\cal C} =(T_h/T_c)^{1/4} in the sudden limit when the irreversibility is dominated by friction. When the engine deviates from adiabatic conditions, the performance is subject to friction. The origin of this friction can be traced to the noncommutability of the kinetic and potential energy of the working medium.

  11. Forming impressions: effects of facial expression and gender stereotypes.

    Science.gov (United States)

    Hack, Tay

    2014-04-01

    The present study of 138 participants explored how facial expressions and gender stereotypes influence impressions. It was predicted that images of smiling women would be evaluated more favorably on traits reflecting warmth, and that images of non-smiling men would be evaluated more favorably on traits reflecting competence. As predicted, smiling female faces were rated as more warm; however, contrary to prediction, perceived competence of male faces was not affected by facial expression. Participants' female stereotype endorsement was a significant predictor for evaluations of female faces; those who ascribed more strongly to traditional female stereotypes reported the most positive impressions of female faces displaying a smiling expression. However, a similar effect was not found for images of men; endorsement of traditional male stereotypes did not predict participants' impressions of male faces.

  12. Impression Management in Social Media: The Example of LinkedIn

    Directory of Open Access Journals (Sweden)

    Joanna Paliszkiewicz

    2016-09-01

    Full Text Available Nowadays, the relationships are often initiated and maintained in online environments, the formation and management of online impressions have gained importance and become the subject of numerous studies. The impression management is a conscious process in which people attempt to influence the perceptions of their image. They do it by controlling and managing information presented in social media. The presentation of identity is the key to success or failure for example in business life. In the article, the critical literature review related to impression management in social media is described. The example of the way of self-presentation in LinkedIn is presented. The future directions are indicated.

  13. Risk Aversion, Price Uncertainty and Irreversible Investments

    NARCIS (Netherlands)

    van den Goorbergh, R.W.J.; Huisman, K.J.M.; Kort, P.M.

    2003-01-01

    This paper generalizes the theory of irreversible investment under uncertainty by allowing for risk averse investors in the absence of com-plete markets.Until now this theory has only been developed in the cases of risk neutrality, or risk aversion in combination with complete markets.Within a

  14. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision.

    Science.gov (United States)

    Ender, Andreas; Mehl, Albert

    2013-02-01

    A new approach to both 3-dimensional (3D) trueness and precision is necessary to assess the accuracy of intraoral digital impressions and compare them to conventionally acquired impressions. The purpose of this in vitro study was to evaluate whether a new reference scanner is capable of measuring conventional and digital intraoral complete-arch impressions for 3D accuracy. A steel reference dentate model was fabricated and measured with a reference scanner (digital reference model). Conventional impressions were made from the reference model, poured with Type IV dental stone, scanned with the reference scanner, and exported as digital models. Additionally, digital impressions of the reference model were made and the digital models were exported. Precision was measured by superimposing the digital models within each group. Superimposing the digital models on the digital reference model assessed the trueness of each impression method. Statistical significance was assessed with an independent sample t test (α=.05). The reference scanner delivered high accuracy over the entire dental arch with a precision of 1.6 ±0.6 µm and a trueness of 5.3 ±1.1 µm. Conventional impressions showed significantly higher precision (12.5 ±2.5 µm) and trueness values (20.4 ±2.2 µm) with small deviations in the second molar region (PDigital impressions were significantly less accurate with a precision of 32.4 ±9.6 µm and a trueness of 58.6 ±15.8µm (Pdigital models were visible across the entire dental arch. The new reference scanner is capable of measuring the precision and trueness of both digital and conventional complete-arch impressions. The digital impression is less accurate and shows a different pattern of deviation than the conventional impression. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  15. Appearing smart: the impression management of intelligence, person perception accuracy, and behavior in social interaction.

    Science.gov (United States)

    Murphy, Nora A

    2007-03-01

    Intelligence is an important trait that affects everyday social interaction. The present research utilized the ecological perspective of social perception to investigate the impression management of intelligence and strangers' evaluations of targets' intelligence levels. The ability to effectively portray an impression of intelligence to outside judges as well as interaction partners was appraised and the effect of impression management on the accurate judgment of intelligence was assessed. In addition, targets' behavior was studied in relation to impression management, perceived intelligence, and actual measured intelligence. Impression-managing targets appeared more intelligent to video judges but not to their interaction partner as compared to controls. The intelligence quotient (IQ) of impression-managing targets was more accurately judged than controls' IQ. Impression-managing targets displayed distinct nonverbal behavioral patterns that differed from controls. Looking while speaking was a key behavior: It significantly correlated with IQ, was successfully manipulated by impression-managing targets, and contributed to higher perceived intelligence ratings.

  16. How to account for irreversibility in integrated assessment of climate change?

    International Nuclear Information System (INIS)

    Ha Duong, M.

    1998-04-01

    How to account for irreversibility in integrated assessment of climate change? This Ph. D. thesis in Economics balances discounting, technical progress and the inertia of existing capital stock against uncertainty and the inertia of socio-economic systems to examine the issue of near term limitations of greenhouse gases emissions. After a general overview in chapter 2, and a more historical presentation of the debates in chapter 3, chapter 4 proceeds to review a large number of integrated assessment models. Chapter 5 introduces a Model on the Dynamics of Inertia and Adaptability of energy systems: DIAM, used to discuss how much previous studies might have overestimated the long term costs of CO 2 limitations and underestimated adjustment costs. It shows that, given a target date for atmospheric CO 2 concentration stabilisation, a higher inertia implies a lower optimal concentration trajectory. In a sequential decision framework, chapter 6 shows that current uncertainties about which CO 2 concentration ceiling would not present dangerous interference with the climate system justifies precautionary action. Finally, chapter 7 uses the irreversibility effect theory to define formally situations of decision under controversy and compare the irreversibility of CO 2 accumulation with the irreversibility of investments needed to moderate it. An option value for greenhouse gases emissions limitations is computed. (author)

  17. Factors influencing optical 3D scanning of vinyl polysiloxane impression materials.

    Science.gov (United States)

    DeLong, R; Pintado, M R; Ko, C C; Hodges, J S; Douglas, W H

    2001-06-01

    Future growth in dental practice lies in digital imaging enhancing many chairside procedures and functions. This revolution requires the fast, accurate, and 3D digitizing of clinical records. One such clinical record is the chairside impression. This study investigated how surface angle and surface roughness affect the digitizing of vinyl polysiloxane impression materials. Seventeen vinyl polysiloxane impression materials were digitized with a white light optical digitizing system. Each sample was digitized at 3 different angles: 0 degrees, 22.5 degrees, and 45 degrees, and 2 digitizer camera f-stops. The digitized images were rendered on a computer monitor using custom software developed under NIH/NIDCR grant DE12225. All the 3D images were rotated to the 0 degrees position, cropped using Corel Photo-Paint 8 (Corel Corp, Ottawa, Ontario, Canada), then saved in the TIFF file format. The impression material area that was successfully digitized was calculated as a percentage of the total sample area, using Optimas 5.22 image processing software (Media Cybernetics, LP, Silver Spring, MD). The dependent variable was a Performance Value calculated for each material by averaging the percentage of area that digitized over the 3 angles. New samples with smooth and rough surfaces were made using the 7 impression materials with the largest Performance Values. These samples were tested as before, but with the additional angle of 60 degrees. Silky-Rock die stone (Whip Mix Corp, Louisville, KY) was used as a control. The Performance Values for the 17 impression materials ranged from 0% to 100%. The Performance Values for the 7 best materials were equivalent to the control at f/11 out to a surface angle of 45 degrees; however, only Examix impression material (GC America Inc, Alsip, IL) was equivalent to the control at f/11/\\16. At the 60 degrees surface angle with f/11/\\16, the Performance Values were 0% for all the impression materials, whereas that for the control was 90

  18. Canonical formalism, fundamental equation, and generalized thermomechanics for irreversible fluids with heat transfer

    International Nuclear Information System (INIS)

    Sieniutycz, S.; Berry, R.S.

    1993-01-01

    A Lagrangian with dissipative (e.g., Onsager's) potentials is constructed for the field description of irreversible heat-conducting fluids, off local equilibrium. Extremum conditions of action yield Clebsch representations of temperature, chemical potential, velocities, and generalized momenta, including a thermal momentum introduced recently [R. L. Selinger and F. R. S. Whitham, Proc. R. Soc. London, Ser. A 302, 1 (1968); S. Sieniutycz and R. S. Berry, Phys. Rev. A 40, 348 (1989)]. The basic question asked is ''To what extent may irreversibility, represented by a given form of the entropy source, influence the analytical form of the conservation laws for the energy and momentum?'' Noether's energy for a fluid with heat flow is obtained, which leads to a fundamental equation and extended Hamiltonian dynamics obeying the second law of thermodynamics. While in the case of the Onsager potentials this energy coincides numerically with the classical energy E, it contains an extra term (vanishing along the path) still contributing to an irreversible evolution. Components of the energy-momentum tensor preserve all terms regarded standardly as ''irreversible'' (heat, tangential stresses, etc.) generalized to the case when thermodynamics includes the state gradients and the so-called thermal phase, which we introduce here. This variable, the Lagrange multiplier of the entropy generation balance, is crucial for consistent treatment of irreversible processes via an action formalism. We conclude with the hypothesis that embedding the first and second laws in the context of the extremal behavior of action under irreversible conditions may imply accretion of an additional term to the classical energy

  19. Reducing job insecurity and increasing performance ratings: does impression management matter?

    Science.gov (United States)

    Huang, Guo-hua; Zhao, Helen Hailin; Niu, Xiong-ying; Ashford, Susan J; Lee, Cynthia

    2013-09-01

    Prior research on job insecurity has demonstrated its detrimental effects on both employees and the organization, yet no research has detailed how people actively deal with it. Drawing from proactivity research, this article argues that job insecurity prompts a proactive use of impression management tactics in the workplace. The effectiveness of these tactics depends on the level of supervisory liking for the employee and the attributions supervisors make regarding the employee's motives for the impression management behaviors (i.e., for the good of the organization or for self-interest). A 3-wave survey study of 271 Chinese employees and their supervisors showed that employees experiencing job insecurity in Time 1 reported using a variety of tactics to impress their supervisors at Time 2 and that these tactics curbed the affect associated with job insecurity and enhanced supervisor rated performance, through supervisor's liking and attributed motives. The relationship between impression management and increased supervisor-rated performance was moderated by supervisor attributions; the relationship between impression management and reduced affective job insecurity depended on supervisor liking. PsycINFO Database Record (c) 2013 APA, all rights reserved

  20. Modification of First Impression Formation and "Personality" by Manipulating Outer Appearance.

    Science.gov (United States)

    Hüttner, Susanne-Marie; Linden, Michael

    2017-01-01

    Global impression is the first item in any psychopathological evaluation, as patients often elicit negative responses in other persons by a dysfunctional first impression formation. This can lead to interactional problems and stigmatization. This study tested to what degree the perception of "personality" can be changed by simple manipulations of the outer appearance of a person. A total of 92 persons were given two different photos of the same female, one with hair combed back and the other with "open" curly hair. For each picture they made ratings on the Bipolar MED Rating Scale, which asks for judgements on 23 emotional impressions. The rating on the "two" persons differed significantly for 16 of the 23 items. Curled open hair led to a more open-hearted and trusting impression, while the combed-back hair was perceived as more reserved, earnest, and defiant. Results were independent of age and gender. People come to far-reaching conclusions about the "personality" of other persons (first impression formation) based on the outer appearance. This opens treatment options for improving social interaction and fighting stigma in patients with mental disorders. © 2017 S. Karger AG, Basel.

  1. Children's Impressions of Television Families.

    Science.gov (United States)

    Wartella, Ellen

    This research study examines the types of social behaviors portrayed by families in various television series and explores children's impressions of the TV family members. Content analysis of nine family-oriented TV series was employed to describe the ranges of behaviors of fathers, mothers and children on television. Eleven shows from each series…

  2. How do you say ‘hello’? Personality impressions from brief novel voices

    OpenAIRE

    McAleer, Phil; Todorov, Alexander; Belin, Pascal

    2014-01-01

    On hearing a novel voice, listeners readily form personality impressions of that speaker. Accurate or not, these impressions are known to affect subsequent interactions; yet the underlying psychological and acoustical bases remain poorly understood. Furthermore, hitherto studies have focussed on extended speech as opposed to analysing the instantaneous impressions we obtain from first experience. In this paper, through a mass online rating experiment, 320 participants rated 64 sub-second voca...

  3. Effectiveness of Disinfectants on Antimicrobial and Physical Properties of Dental Impression Materials.

    Science.gov (United States)

    Demajo, Jean Karl; Cassar, Valter; Farrugia, Cher; Millan-Sango, David; Sammut, Charles; Valdramidis, Vasilis; Camilleri, Josette

    2016-01-01

    The aim of this study was to assess the antimicrobial activity of chemical disinfectants on alginate and silicone impression materials. The effect of chemical disinfectants on the dimensional stability of the impression materials was also assessed. For the microbiologic assessment, impressions of the maxillary arch were taken from 14 participants, 7 using alginate and 7 using an addition silicone. The impressions were divided into three sections. Each section was subjected to spraying with MD 520 or Minuten or no disinfection (control), respectively. Antimicrobial action of the chemical disinfectants was assessed by measuring microbial counts in trypticase soy agar (TSA) media and expressing the results in colony-forming units/cm2. The surface area of the dental impressions was calculated by scanning a stone cast using computer-aided design/computer-assisted manufacture and analyzing the data using a custom computer program. The dimensional stability of the impression materials after immersion in disinfectants was assessed by measuring the linear displacement of horizontally restrained materials using a traveling microscope. The percent change in length over 3 hours was thus determined. Alginate exhibited a higher microbial count than silicone. MD 520 eliminated all microbes as opposed to Minuten. The bacterial growth after Minuten disinfection was almost twice as much for alginate than for addition silicone impressions. The chemical disinfectants affected the alginate dimensional stability. Minuten reduced the shrinkage sustained by alginate during the first hour of storage. Alginate harbors three times more microorganisms than silicone impression material. Chemical disinfection by glutaraldehyde-based disinfectant was effective in eliminating all microbial forms for both alginate and silicone without modifying the dimensional stability. Alcohol-based disinfectants, however, reduced the alginate shrinkage during the first 90 minutes of setting. The current studies

  4. Comparison of Accuracy Between a Conventional and Two Digital Intraoral Impression Techniques.

    Science.gov (United States)

    Malik, Junaid; Rodriguez, Jose; Weisbloom, Michael; Petridis, Haralampos

    To compare the accuracy (ie, precision and trueness) of full-arch impressions fabricated using either a conventional polyvinyl siloxane (PVS) material or one of two intraoral optical scanners. Full-arch impressions of a reference model were obtained using addition silicone impression material (Aquasil Ultra; Dentsply Caulk) and two optical scanners (Trios, 3Shape, and CEREC Omnicam, Sirona). Surface matching software (Geomagic Control, 3D Systems) was used to superimpose the scans within groups to determine the mean deviations in precision and trueness (μm) between the scans, which were calculated for each group and compared statistically using one-way analysis of variance with post hoc Bonferroni (trueness) and Games-Howell (precision) tests (IBM SPSS ver 24, IBM UK). Qualitative analysis was also carried out from three-dimensional maps of differences between scans. Means and standard deviations (SD) of deviations in precision for conventional, Trios, and Omnicam groups were 21.7 (± 5.4), 49.9 (± 18.3), and 36.5 (± 11.12) μm, respectively. Means and SDs for deviations in trueness were 24.3 (± 5.7), 87.1 (± 7.9), and 80.3 (± 12.1) μm, respectively. The conventional impression showed statistically significantly improved mean precision (P < .006) and mean trueness (P < .001) compared to both digital impression procedures. There were no statistically significant differences in precision (P = .153) or trueness (P = .757) between the digital impressions. The qualitative analysis revealed local deviations along the palatal surfaces of the molars and incisal edges of the anterior teeth of < 100 μm. Conventional full-arch PVS impressions exhibited improved mean accuracy compared to two direct optical scanners. No significant differences were found between the two digital impression methods.

  5. [Study on the effect of different impression methods on the marginal fit of all-ceramic crowns].

    Science.gov (United States)

    Zhan, Lilin; Zeng, Liwei; Chen, Ping; Liao, Lan; Li, Shiyue; Liu, Renying

    2015-08-01

    To investigate the effect of three different impression methods on the marginal fit of all-ceramic crowns. The three methods include scanning silicone rubber impression, cast models, and direct optical impression. The polymethyl methacrylate (PMMA) material of a mandibular first molar in standard model was prepared with 16 models duplicated. The all-ceramic crowns were prepared using three different impression methods. Accurate impressions were made using silicone rubber, and the cast models were obtained. The PMMA models, silicone rubber impressions, and cast models were scanned, and digital models of three groups were obtained to produce 48 zirconia all-ceramic crowns with computer aided design/computer aided manufacture. The marginal fit of these groups was measured by silicone rubber gap impression. Statistical analysis was performed with SPSS 17.0 software. The marginal fit of direct optical impression groups, silicone rubber impression groups, cast model groups was (69.18±9.47), (81.04±10.88), (84.42±9.96) µm. A significant difference was observed in the marginal fit of the direct optical impression groups and the other groups (Pimpression groups and the cast model groups (P>0.05). All marginal measurement sites are clinically acceptable by the three different impression scanning methods. The silicone rubber impression scanning method can be used for all-ceramic restorations.

  6. Health Technology Assessment of CEM Pulpotomy in Permanent Molars with Irreversible Pulpitis

    Science.gov (United States)

    Yazdani, Shahram; Jadidfard, Mohammad-Pooyan; Tahani, Bahareh; Kazemian, Ali; Dianat, Omid; Alim Marvasti, Laleh

    2014-01-01

    Introduction: Teeth with irreversible pulpitis usually undergo root canal therapy (RCT). This treatment modality is often considered disadvantageous as it removes vital pulp tissue and weakens the tooth structure. A relatively new concept has risen which suggests vital pulp therapy (VPT) for irreversible pulpitis. VPT with calcium enriched mixture (VPT/CEM) has demonstrated favorable treatment outcomes when treating permanent molars with irreversible pulpitis. This study aims to compare patient related factors, safety and organizational consideration as parts of health technology assessment (HTA) of the new VPT/CEM biotechnology when compared with RCT. Materials and Methods: Patient related factors were assessed by looking at short- and long-term clinical success; safety related factors were evaluated by a specialist committee and discussion board involved in formulating healthcare policies. Organizational evaluation was performed and the social implications were assessed by estimating the costs, availability, accessibility and acceptability. The impact of VPT/CEM biotechnology was assessed by investigating the incidence of irreversible pulpitis and the effect of this treatment on reducing the burden of disease. Results: VPT/CEM biotechnology was deemed feasible and acceptable like RCT; however, it was more successful, accessible, affordable, available and also safer than RCT. Conclusion: When considering socioeconomic implications on oral health status and oral health-related quality of life of VPT/CEM, the novel biotechnology can be more effective and more efficient than RCT in mature permanent molars with irreversible pulpitis. PMID:24396372

  7. Onsager's reciprocity theorem in extended irreversible thermodynamics

    International Nuclear Information System (INIS)

    Garcia-Colin, L.S.; Velasco, R.M.

    1992-01-01

    In this paper we shall discuss the Onsager relations for the transport coefficients in a dilute monatomic gas described by the extended irreversible thermodynamics. Our discussion is based on a 26 variables description of the system and its corresponding comparison with the kinetic reciprocity between coefficients is shown (Author)

  8. A new method for assessing the accuracy of full arch impressions in patients.

    Science.gov (United States)

    Kuhr, F; Schmidt, A; Rehmann, P; Wöstmann, B

    2016-12-01

    To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°). The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register). Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Neurofibromatosis, stroke and basilar impression: case report Neurofibromatose, acidente vascular cerebral e impressão basilar: relato de caso

    Directory of Open Access Journals (Sweden)

    ELCIO JULIATO PIOVESAN

    1999-06-01

    Full Text Available Neurofibromatosis type 1 (NF1 can virtually affect any organ, presenting most frequently with "cafe au lait" spots and neurofibromas. Vasculopathy is a known complication of NF1, but cerebrovascular disease is rare. We report the case of a 51-year-old man admitted to the hospital with a history of stroke four months before admission. On physical examination, he presented various "cafe au lait" spots and cutaneous neurofibromas. Neurologic examination demonstrated right-sided facial paralysis, right-sided hemiplegia, and aphasia. Computed tomography scan of head showed hypodense areas in the basal ganglia and centrum semiovale. Radiographs of cranium and cervical spine showed basilar impression. Angiography revealed complete occlusion of both vertebral and left internal carotid arteries, and partial stenosis of the right internal carotid artery. A large network of collateral vessels was present (moyamoya syndrome. It is an uncommon case of occlusive cerebrovascular disease associated with NF1, since most cases described in the literature are in young people, and tend to spare the posterior cerebral circulation. Basilar impression associated with this case may be considered a pure coincidence, but rare cases of basilar impression and NF1 have been described.A neurofibromatose tipo 1 (NF1 pode acometer qualquer órgão mas as apresentações mais frequente são manchas café com leite e neurofibromas. O envolvimento de vasos é complicação conhecida da NF1, mas a doença cerebrovascular é rara. Relatamos o caso de paciente do sexo masculino de 51 anos com história de acidente vascular cerebral há quatro meses da admissão. Ao exame físico apresentava várias manchas café com leite e neurofibromas cutâneos. O exame neurológico demonstrou acometimento facial direito, hemiplegia direita e afasia. Tomografia computadorizada de crânio mostrou áreas hipodensas nos gânglios basais e centros semi-ovais. Radiografias do crânio e coluna cervical

  10. Effect of storage period on the accuracy of elastomeric impressions

    Directory of Open Access Journals (Sweden)

    Eduardo Batista Franco

    2007-06-01

    Full Text Available AIMS: To investigate the effect of the storage period on the accuracy of recently developed elastomeric materials. METHODS: Simultaneous impressions of a steel die were taken using a polyether (I: Impregum Soft Heavy and Light body, 3M ESPE and vinyl polysiloxane (P: Perfectim Blue Velvet and Flexi-Velvet, J.Morita. The trays were loaded with the heavy-bodied impression materials while the light-bodied impression materials were simultaneously spread on the steel die. The impressions were poured after 2 hours, 24 hours, and 7 days. Impressions were stored at approximately 55% relative humidity and room temperature. Ten replicas were produced for each experimental condition (n=60. Accuracy of the stone dies was assessed with a depth-measuring microscope. The difference in height between the surface of the stone die and a standard metallic ring was recorded in micrometers at four demarcated points, by two independent examiners. Data were submitted to two-way ANOVA and Tukey test (a = 0.05. RESULTS: Significant differences were found among the groups. Smaller discrepancies were observed when pouring was performed up to 24 hours (I-2h= 65.0 ± 15.68 µm; I-24h= 81.6 ± 11.13 µm for the polyether, and up to 7 days for the vinyl polysiloxane (P-2h= 79.1 ± 13.82 µm; P-24h= 96.8 ± 6.02 µm; P-7d= 81.4 ± 4.3 µm. Significant dimensional discrepancies, however, were observed when polyether was stored for 7 days (I-7d= 295.3 ± 17.4 µm. CONCLUSION: Storage may significantly affect the dimensional accuracy of impressions and, thus, a maximum period and storage condition should be specified for the recently developed materials.

  11. Contact angle of unset elastomeric impression materials.

    Science.gov (United States)

    Menees, Timothy S; Radhakrishnan, Rashmi; Ramp, Lance C; Burgess, John O; Lawson, Nathaniel C

    2015-10-01

    Some elastomeric impression materials are hydrophobic, and it is often necessary to take definitive impressions of teeth coated with some saliva. New hydrophilic materials have been developed. The purpose of this in vitro study was to compare contact angles of water and saliva on 7 unset elastomeric impression materials at 5 time points from the start of mixing. Two traditional polyvinyl siloxane (PVS) (Aquasil, Take 1), 2 modified PVS (Imprint 4, Panasil), a polyether (Impregum), and 2 hybrid (Identium, EXA'lence) materials were compared. Each material was flattened to 2 mm and a 5 μL drop of distilled water or saliva was dropped on the surface at 25 seconds (t0) after the start of mix. Contact angle measurements were made with a digital microscope at initial contact (t0), t1=2 seconds, t2=5 seconds, t3=50% working time, and t4=95% working time. Data were analyzed with a generalized linear mixed model analysis, and individual 1-way ANOVA and Tukey HSD post hoc tests (α=.05). For water, materials grouped into 3 categories at all time-points: the modified PVS and one hybrid material (Identium) produced the lowest contact angles, the polyether material was intermediate, and the traditional PVS materials and the other hybrid (EXA'lence) produced the highest contact angles. For saliva, Identium, Impregum, and Imprint 4 were in the group with the lowest contact angle at most time points. Modified PVS materials and one of the hybrid materials are more hydrophilic than traditional PVS materials when measured with water. Saliva behaves differently than water in contact angle measurement on unset impression material and produces a lower contact angle on polyether based materials. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials.

    Science.gov (United States)

    Rudolph, Heike; Quaas, Sebastian; Haim, Manuela; Preißler, Jörg; Walter, Michael H; Koch, Rainer; Luthardt, Ralph G

    2013-06-01

    The use of fast-setting impression materials with different viscosities for the one-stage impression technique demands precise working times when mixing. We examined the effect of varying working time on impression precision in a randomized clinical trial. Focusing on tooth 46, three impressions were made from each of 96 volunteers, using either a polyether (PE: Impregum Penta H/L DuoSoft Quick, 3 M ESPE) or an addition-curing silicone (AS: Aquasil Ultra LV, Dentsply/DeTrey), one with the manufacturer's recommended working time (used as a reference) and two with altered working times. All stages of the impression-taking were subject to randomization. The three-dimensional precision of the non-standard working time impressions was digitally analyzed compared to the reference impression. Statistical analysis was performed using multivariate models. The mean difference in the position of the lower right first molar (vs. the reference impression) ranged from ±12 μm for PE to +19 and -14 μm for AS. Significantly higher mean values (+62 to -40 μm) were found for AS compared to PE (+21 to -26 μm) in the area of the distal adjacent tooth. Fast-set impression materials offer high precision when used for single tooth restorations as part of a one-stage impression technique, even when the working time (mixing plus application of the light- and heavy-body components) diverges significantly from the manufacturer's recommended protocol. Best accuracy was achieved with machine-mixed heavy-body/light-body polyether. Both materials examined met the clinical requirements regarding precision when the teeth were completely syringed with light material.

  13. Lie-admissible invariant treatment of irreversibility for matter and antimatter at the classical and operator levels

    International Nuclear Information System (INIS)

    Santilli, R.M.

    2006-01-01

    It was generally believed throughout the 20th century that irreversibility is a purely classical event without operator counterpart. however, a classical irreversible system cannot be consistently decomposed into a finite number of reversible quantum particles (and. vive versa), thus establishing that the origin of irreversibility is basically unknown at the dawn of the 21-st century. To resolve this problem. we adopt the historical analytical representation of irreversibility by Lagrange and Hamilton, that with external terms in their analytic equations; we show that, when properly written, the brackets of the time evolution characterize covering Lie-admissible algebras; we prove that the formalism has fully consistent operator counterpart given by the Lie-admissible branch of hadronic mechanics; we identify mathematical and physical inconsistencies when irreversible formulations are treated with the conventional mathematics used for reversible systems; we show that when the dynamical equations are treated with a novel irreversible mathematics, Lie-admissible formulations are fully consistent because invariant at both the classical and operator levels; and we complete our analysis with a number of explicit applications to irreversible processes in classical mechanics, particle physics and thermodynamics. The case of closed-isolated systems verifying conventional total conservation laws, yet possessing an irreversible structure, is treated via the simpler Lie-isotopic branch of hadronic mechanics. The analysis is conducted for both matter and antimatter at the classical and operator levels to prevent insidious inconsistencies occurring for the sole study of matter or, separately, antimatter

  14. Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses.

    Science.gov (United States)

    Takeuchi, Yoshimasa; Koizumi, Hiroyasu; Furuchi, Mika; Sato, Yohei; Ohkubo, Chikahiro; Matsumura, Hideo

    2018-01-01

    Accurate impressions are essential in fabri-cating dental restorations and fixed dental prostheses. During the last decade, digital impression systems have improved substantially. This review discusses the accuracy of digital impression systems for fabrication of dental restorations and fixed dental prostheses. A literature search in PubMed was performed for the period from July 2010 through June 2017. The search keywords were Cerec, digital impression, direct digitalization, indirect digitalization, and intraoral scanner. Only relevant studies are summarized and discussed in this review. In general, the latest systems have considerably reduced the time required for impression making, and the accuracy and marginal fit of digital impression systems have recently improved. Restorations and fixed dental prostheses fabricated with currently available digital impression systems and intraoral scanners exhibit clinically acceptable ranges of marginal gap in both direct and indirect procedures.

  15. Oxytocin and first impressions

    OpenAIRE

    Friberg, Mads

    2012-01-01

    Subtle facial expressions may cause "core impressions" of other people, i.e. a feeling of like or dislike witch is affected by facial cues that is not explicitly and consciously recognized. In the present investigation, we were interested in how the neuropeptide oxytocin affects recognition of these subtle facial expressions. Participants received oxytocin or placebo, and viewed static and dynamic "hybrid" faces that showed a facial expression (happiness, anger, fear, sadness) only in the lo...

  16. Managing impressions and forests

    OpenAIRE

    Ångman, Elin; Hallgren, Lars; Nordström, Eva-Maria

    2011-01-01

    Social interaction is an important—and often forgotten—aspect of conflicts in natural resource management (NRM). Building on the theoretical framework of symbolic interaction, this article explores how the concept of impression management during social interaction can help understand NRM conflicts. A qualitative study was carried out on a Swedish case involving a conflict over clear-cutting of a forest. To explain why the conflict escalated and destructivity increased, we investigated how the...

  17. Spectral deformation techniques applied to the study of quantum statistical irreversible processes

    International Nuclear Information System (INIS)

    Courbage, M.

    1978-01-01

    A procedure of analytic continuation of the resolvent of Liouville operators for quantum statistical systems is discussed. When applied to the theory of irreversible processes of the Brussels School, this method supports the idea that the restriction to a class of initial conditions is necessary to obtain an irreversible behaviour. The general results are tested on the Friedrichs model. (Auth.)

  18. Development of a digital impression procedure using photogrammetry for complete denture fabrication.

    Science.gov (United States)

    Matsuda, Takashi; Goto, Takaharu; Kurahashi, Kosuke; Kashiwabara, Toshiya; Ichikawa, Tetsuo

    We developed an innovative procedure for digitizing maxillary edentulous residual ridges with a photogrammetric system capable of estimating three-dimensional (3D) digital forms from multiple two-dimensional (2D) digital images. The aim of this study was to validate the effectiveness of the photogrammetric system. Impressions of the maxillary residual ridges of five edentulous patients were taken with four kinds of procedures: three conventional impression procedures and the photogrammetric system. Plaster models were fabricated from conventional impressions and digitized with a 3D scanner. Two 3D forms out of four forms were superimposed with 3D inspection software, and differences were evaluated using a least squares best fit algorithm. The in vitro experiment suggested that better imaging conditions were in the horizontal range of ± 15 degrees and at a vertical angle of 45 degrees. The mean difference between the photogrammetric image (Form A) and the image taken from conventional preliminarily impression (Form C) was 0.52 ± 0.22 mm. The mean difference between the image taken of final impression through a special tray (Form B) and Form C was 0.26 ± 0.06 mm. The mean difference between the image taken from conventional final impression (Form D) and Form C was 0.25 ± 0.07 mm. The difference between Forms A and C was significantly larger than the differences between Forms B and C and between Forms D and C. The results of this study suggest that obtaining digital impressions of edentulous residual ridges using a photogrammetric system is feasible and available for clinical use.

  19. The effect of impression volume and double-arch trays on the registration of maximum intercuspation.

    Science.gov (United States)

    Hahn, Sara M; Millstein, Philip L; Kinnunen, Taru H; Wright, Robert F

    2009-12-01

    The type of double-arch trays used may affect occlusion. The purpose of this study was to determine what effect, if any, double-arch tray design and impression material volume had on the registration of maximum intercuspation (MI). Quadrant impressions were made on articulated fracture-resistant dental casts mounted in maximum intercuspation occlusion. Three types of sideless double-arch impression trays were used: First Bite with nylon webbing, Sultan's 3-Way with double crosshatch webbing, and Premium's 3-in-1 Tray with single crosshatch webbing. Vinyl polysiloxane impression material (Aquasil Ultra Rigid Fast Set) was distributed at 2 different volumes (5.4 ml and 8.3 ml), and 60 impressions were made (n=10). A weight of 1.2 kg was placed on the upper arm of an Artex articulator, ensuring complete closure. The impressions were allowed to polymerize for 5 minutes. After polymerization, specimens were placed on a light box, and a camera set at a fixed distance was used to capture the light transmission that was projected through the impression material. The camera transferred the information to an image analysis program (ImageJ). This system allowed the different amounts of light projected through the impression to be translated into a gray scale value (GSV), which was assigned a thickness value, in millimeters, of a specified occlusal contact area. To assess reliability of the experimental design, 10 control impressions were made by directly applying impression material onto the typodont. These were analyzed in the same manner as the impressions made with trays. A 2-way ANOVA comparing volume by tray type was used (alpha=.05). This was followed by a Tukey HSD test. There was no main effect for volume of impression material (P=.71). Tray type was significantly different (Precord making.

  20. Crime scene reconstruction-Sex prediction from blood stained foot sole impressions.

    Science.gov (United States)

    Basu, Nabanita; Bandyopadhyay, Samir Kumar

    2017-09-01

    It is often difficult to predict the sex of an individual based on bloody incomplete footprints. However, such prints/impressions are particularly common in a crime scene. Again variability in the texture, color of the target surface has an impact on the bloodstained impression formed. The study of bare foot, footprint, footwear (i.e. shoe, canvas etc.) within the legal context is referred to as forensic podiatry. Based on the fact that it is possible to predict the sex of an individual from footprint impressions, an automated model has been proposed in this paper for analyzing the sex of an individual from his/her broken/incomplete footprint impressions based on morphological features alone. Five male and female volunteers aged between 20 to 65 years participated in dataset development. Keeping the blood volume constant and having stepped on differently shaped porcine blood pools, the individuals were asked to walk on herbarium sheets. The footprints were recorded and documented in accordance with the guidelines in place for physical evidence documentation within the forensic domain. The morphological features that were extracted from each of the footprint impressions are footprint length, footprint breadth, angle of walking, approximated heel radius etc. Using exhaustive cross validation technique, the dataset was divided into training and test set. Non-redundant, relevant features that are particularly effective at sex prediction were marked out using the relief algorithm in coherence with the correlation metric. Supervised learning techniques were used on the dataset to predict the sex of the owner of an unknown footprint. The study concentrates on morphological features in order to deal with bloodstain footprint transfer stains formed on any non-porous/non-absorbent surfaces such as cemented floor, glass, mosaic floor space, colored and designed tiled floor spaces. Features such as the angle of walking and foot breadth were found to be particularly influential

  1. Articaine for supplemental intraosseous anesthesia in patients with irreversible pulpitis.

    Science.gov (United States)

    Bigby, Jason; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel

    2006-11-01

    The purpose of this study was to determine the anesthetic efficacy and heart rate effect of 4% articaine with 1:100,000 epinephrine for supplemental intraosseous injection in mandibular posterior teeth diagnosed with irreversible pulpitis. Thirty-seven emergency patients, diagnosed with irreversible pulpitis of a mandibular posterior tooth, received an inferior alveolar nerve block and had moderate-to-severe pain upon endodontic access. The Stabident system was used to administer 1.8 ml of 4% articaine with 1:100,000 epinephrine. Success of the intraosseous injection was defined as none or mild pain upon endodontic access or initial instrumentation. The results demonstrated that anesthetic success was obtained in 86% (32 of 37) of the patients. Maximum mean heart rate was increased 32 beats/minute during the intraosseous injection. We can conclude that when the inferior alveolar nerve block fails to provide profound pulpal anesthesia, the intraosseous injection of 4% articaine with 1:100,000 epinephrine would be successful 86% of the time in achieving pulpal anesthesia in mandibular posterior teeth of patients presenting with irreversible pulpitis.

  2. Dishonest responding or true virtue? A behavioral test of impression management

    NARCIS (Netherlands)

    Zettler, I.; Hilbig, B.E.; Moshagen, M.; de Vries, R.E.

    2015-01-01

    Impression management or social desirability scales have been used widely to assess and control for self-favoring biases in self-reports, both in low and high demand situations. Recently, however, substantive interpretations of impression management scores have surfaced, including the simple but

  3. FINITE TIME THERMODYNAMIC MODELING AND ANALYSIS FOR AN IRREVERSIBLE ATKINSON CYCLE

    Directory of Open Access Journals (Sweden)

    Yanlin Ge

    2010-01-01

    Full Text Available Performance of an air-standard Atkinson cycle is analyzed by using finite-time thermodynamics. The irreversible cycle model which is more close to practice is founded. In this model, the non-linear relation between the specific heats of working fluid and its temperature, the friction loss computed according to the mean velocity of the piston, the internal irreversibility described by using the compression and expansion efficiencies, and heat transfer loss are considered. The relations between the power output and the compression ratio, between the thermal efficiency and the compression ratio, as well as the optimal relation between power output and the efficiency of the cycle are derived by detailed numerical examples. Moreover, the effects of internal irreversibility, heat transfer loss and friction loss on the cycle performance are analyzed. The results obtained in this paper may provide guidelines for the design of practical internal combustion engines.

  4. Passive fit and accuracy of three dental implant impression techniques.

    Science.gov (United States)

    Al Quran, Firas A; Rashdan, Bashar A; Zomar, AbdelRahman A Abu; Weiner, Saul

    2012-02-01

    To reassess the accuracy of three impression techniques relative to the passive fit of the prosthesis. An edentulous maxillary cast was fabricated in epoxy resin with four dental implants embedded and secured with heat-cured acrylic resin. Three techniques were tested: closed tray, open tray nonsplinted, and open tray splinted. One light-cured custom acrylic tray was fabricated for each impression technique, and transfer copings were attached to the implants. Fifteen impressions for each technique were prepared with medium-bodied consistency polyether. Subsequently, the impressions were poured in type IV die stone. The distances between the implants were measured using a digital micrometer. The statistical analysis of the data was performed with ANOVA and a one-sample t test at a 95% confidence interval. The lowest mean difference in dimensional accuracy was found within the direct (open tray) splinted technique. Also, the one-sample t test showed that the direct splinted technique has the least statistical significant difference from direct nonsplinted and indirect (closed tray) techniques. All discrepancies were less than 100 Μm. Within the limitations of this study, the best accuracy of the definitive prosthesis was achieved when the impression copings were splinted with autopolymerized acrylic resin, sectioned, and rejoined. However, the errors associated with all of these techniques were less than 100 Μm, and based on the current definitions of passive fit, they all would be clinically acceptable.

  5. Impression Procedures for Metal Frame Removable Partial Dentures as Applied by General Dental Practitioners.

    NARCIS (Netherlands)

    Fokkinga, W.A.; Uchelen, J. van; Witter, D.J.; Mulder, J.; Creugers, N.H.J.

    2016-01-01

    This pilot study analyzed impression procedures for conventional metal frame removable partial dentures (RPDs). Heads of RPD departments of three dental laboratories were asked to record features of all incoming impressions for RPDs during a 2-month period. Records included: (1) impression

  6. Ecological optimization and performance study of irreversible Stirling and Ericsson heat engines

    International Nuclear Information System (INIS)

    Tyagi, S K; Kaushik, S C; Salhotra, R

    2002-01-01

    The concept of finite time thermodynamics is used to determine the ecological function of irreversible Stirling and Ericsson heat engine cycles. The ecological function is defined as the power output minus power loss (irreversibility), which is the ambient temperature times, the entropy generation rate. The ecological function is maximized with respect to cycle temperature ratio and the expressions for the corresponding power output and thermal efficiency are derived at the optimal operating conditions. The effect of different operating parameters, the effectiveness on the hot, cold and the regenerative side heat exchangers, the cycle temperature ratio, heat capacitance ratio and the internal irreversibility parameter on the maximum ecological function are studied. It is found that the effect of regenerator effectiveness is more than the hot and cold side heat exchangers and the effect of the effectiveness on cold side heat exchanger is more than the effectiveness on the hot side heat exchanger on the maximum ecological function. It is also found that the effect of internal irreversibility parameter is more than the other parameters not only on the maximum ecological function but also on the corresponding power output and the thermal efficiency

  7. Performance characteristics and parametric optimization of an irreversible magnetic Ericsson heat-pump

    International Nuclear Information System (INIS)

    Wei Fang; Lin Guoxing; Chen Jincan; Brueck, Ekkes

    2011-01-01

    Taking into account the finite-rate heat transfer in the heat-transfer processes, heat leak between the two external heat reservoirs, regenerative loss, regeneration time, and internal irreversibility due to dissipation of the cycle working substance, an irreversible magnetic Ericsson heat-pump cycle is presented. On the basis of the thermodynamic properties of magnetic materials, the performance characteristics of the irreversible magnetic Ericsson heat-pump are investigated and the relationship between the optimal heating load and the coefficient of performance (COP) is derived. Moreover, the maximum heating load and the corresponding COP as well as the maximum COP and the corresponding heating load are obtained. Furthermore, the other optimal performance characteristics are discussed in detail. The results obtained here may provide some new information for the optimal parameter design and the development of real magnetic Ericsson heat-pumps. -- Research Highlights: →The effects of multi-irreversibilities on the performance of a magnetic heat-pump are revealed. →Mathematical expressions of the heating load and the COP are derived and the optimal performance and operating parameters are analyzed and discussed. →Several important performance bounds are determined.

  8. Ecological optimization and performance study of irreversible Stirling and Ericsson heat engines

    Science.gov (United States)

    Tyagi, S. K.; Kaushik, S. C.; Salhotra, R.

    2002-10-01

    The concept of finite time thermodynamics is used to determine the ecological function of irreversible Stirling and Ericsson heat engine cycles. The ecological function is defined as the power output minus power loss (irreversibility), which is the ambient temperature times, the entropy generation rate. The ecological function is maximized with respect to cycle temperature ratio and the expressions for the corresponding power output and thermal efficiency are derived at the optimal operating conditions. The effect of different operating parameters, the effectiveness on the hot, cold and the regenerative side heat exchangers, the cycle temperature ratio, heat capacitance ratio and the internal irreversibility parameter on the maximum ecological function are studied. It is found that the effect of regenerator effectiveness is more than the hot and cold side heat exchangers and the effect of the effectiveness on cold side heat exchanger is more than the effectiveness on the hot side heat exchanger on the maximum ecological function. It is also found that the effect of internal irreversibility parameter is more than the other parameters not only on the maximum ecological function but also on the corresponding power output and the thermal efficiency.

  9. How do you say 'hello'? Personality impressions from brief novel voices.

    Science.gov (United States)

    McAleer, Phil; Todorov, Alexander; Belin, Pascal

    2014-01-01

    On hearing a novel voice, listeners readily form personality impressions of that speaker. Accurate or not, these impressions are known to affect subsequent interactions; yet the underlying psychological and acoustical bases remain poorly understood. Furthermore, hitherto studies have focussed on extended speech as opposed to analysing the instantaneous impressions we obtain from first experience. In this paper, through a mass online rating experiment, 320 participants rated 64 sub-second vocal utterances of the word 'hello' on one of 10 personality traits. We show that: (1) personality judgements of brief utterances from unfamiliar speakers are consistent across listeners; (2) a two-dimensional 'social voice space' with axes mapping Valence (Trust, Likeability) and Dominance, each driven by differing combinations of vocal acoustics, adequately summarises ratings in both male and female voices; and (3) a positive combination of Valence and Dominance results in increased perceived male vocal Attractiveness, whereas perceived female vocal Attractiveness is largely controlled by increasing Valence. Results are discussed in relation to the rapid evaluation of personality and, in turn, the intent of others, as being driven by survival mechanisms via approach or avoidance behaviours. These findings provide empirical bases for predicting personality impressions from acoustical analyses of short utterances and for generating desired personality impressions in artificial voices.

  10. How do you say 'hello'? Personality impressions from brief novel voices.

    Directory of Open Access Journals (Sweden)

    Phil McAleer

    Full Text Available On hearing a novel voice, listeners readily form personality impressions of that speaker. Accurate or not, these impressions are known to affect subsequent interactions; yet the underlying psychological and acoustical bases remain poorly understood. Furthermore, hitherto studies have focussed on extended speech as opposed to analysing the instantaneous impressions we obtain from first experience. In this paper, through a mass online rating experiment, 320 participants rated 64 sub-second vocal utterances of the word 'hello' on one of 10 personality traits. We show that: (1 personality judgements of brief utterances from unfamiliar speakers are consistent across listeners; (2 a two-dimensional 'social voice space' with axes mapping Valence (Trust, Likeability and Dominance, each driven by differing combinations of vocal acoustics, adequately summarises ratings in both male and female voices; and (3 a positive combination of Valence and Dominance results in increased perceived male vocal Attractiveness, whereas perceived female vocal Attractiveness is largely controlled by increasing Valence. Results are discussed in relation to the rapid evaluation of personality and, in turn, the intent of others, as being driven by survival mechanisms via approach or avoidance behaviours. These findings provide empirical bases for predicting personality impressions from acoustical analyses of short utterances and for generating desired personality impressions in artificial voices.

  11. Ecological optimization of an irreversible quantum Carnot heat engine with spin-1/2 systems

    International Nuclear Information System (INIS)

    Liu Xiaowei; Chen Lingen; Wu Feng; Sun Fengrui

    2010-01-01

    A model of a quantum heat engine with heat resistance, internal irreversibility and heat leakage and many non-interacting spin-1/2 systems is established in this paper. The quantum heat engine cycle is composed of two isothermal processes and two irreversible adiabatic processes and is referred to as a spin quantum Carnot heat engine. Based on the quantum master equation and the semi-group approach, equations of some important performance parameters, such as power output, efficiency, entropy generation rate and ecological function (a criterion representing the optimal compromise between exergy output rate and exergy loss rate), for the irreversible spin quantum Carnot heat engine are derived. The optimal ecological performance of the heat engine in the classical limit is analyzed with numerical examples. The effects of internal irreversibility and heat leakage on ecological performance are discussed in detail.

  12. Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes.

    Science.gov (United States)

    Yuzbasioglu, Emir; Kurt, Hanefi; Turunc, Rana; Bilir, Halenur

    2014-01-30

    The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects' attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques.

  13. [Impression management and self-presentation in occupational life].

    Science.gov (United States)

    Stresemann, E

    2013-06-01

    Impression management serves self-preservation as part of self-experience. It is adapted to a given situation as an expression of understanding of the role it plays in striving for success. Impression management and self-presentation mutually influence each other throughout life. Clichés in the traditional self-presentation of men and woman in their gender-specific domain in occupation belong to the past. In employment, contentment as much as discontent are of prime importance for success or failure in the workplace. As role models attract mainly juveniles, they should be held up to critical scrutiny.

  14. A clinical report on the use of closed-tray, hex-lock-friction-fit implant impression copings.

    Science.gov (United States)

    Raviv, Eli; Hanna, Jan; Raviv, Roy; Harel-Raviv, Mili

    2014-08-01

    The precision of an impression determines the subsequent accuracy and fit of the final restoration. Therefore, the ultimate search is for the most accurate impression material and the most efficient and least time consuming technique. One of the major debates in implant dentistry has focused on the advantages of the pick-up versus the transfer impression technique. The pick-up technique is widely accepted as the more accurate. However, the conventional transfer technique is simpler and less time consuming. The Hex-Lock-Friction-Fit impression coping (AB Dental Devices) combines the advantages of the transfer impression technique and the pick-up impression technique. In this article we will review the relevant literature, discuss the advantages of this unique implant impression technique, and present some related clinical cases.

  15. Coping with stereotype threat: denial as an impression management strategy.

    Science.gov (United States)

    von Hippel, William; von Hippel, Courtney; Conway, Leanne; Preacher, Kristopher J; Schooler, Jonathan W; Radvansky, Gabriel A

    2005-07-01

    Four experiments tested the hypothesis that people who are concerned with impression management cope with stereotype threat through denial. Consistent with this hypothesis, temporary employees threatened by a stereotype of incompetence (Study 1) and hostel-dwelling older adults (Study 2) were more likely to deny incompetence if they were high in impression management. African Americans (Study 3) showed a similar pattern of denying cognitive incompetence, which emerged primarily when they were interviewed by a White experimenter and had attended a predominantly Black high school. In Study 4, White students who expected to take an IQ test and were threatened by a stereotype of being less intelligent than Asians were more likely to deny that intelligence is important if they were high in impression management.

  16. Bragging on Facebook: The Interaction of Content Source and Focus in Online Impression Formation.

    Science.gov (United States)

    Scott, Graham G; Ravenscroft, Kirsty

    2017-01-01

    Warranting Theory proposes that third-party testimonials are more influential in online impression formation than target-authored statements. Individuals posting content on social media accurately convey their offline personality while endeavoring to present themselves in a positive light. In doing so, they may misjudge the psychological distance of the majority of viewers, who could view this positive self-presentation as bragging and form resultant negative impressions. In this study, we asked 136 participants to view the Facebook timelines of four female targets. Timeline content varied by source (owner- vs. friend-authored) and focus (generally positive vs. personally positive). Participants were tasked with forming impressions of targets and rating them based on attractiveness, confidence, modesty, and popularity. We found that source and focus played distinct roles in impression formation. More positive impressions were formed when owner-authored content was general, and when friend-authored content was personal. This highlights the role played by content focus in impression formation, and the potentially damaging effect of perceived bragging. These results are discussed in relation to the application of the Warranting Theory of impression formation online, and discrepancies between these results and those from related articles are examined.

  17. Profit rate performance optimization for a generalized irreversible ...

    Indian Academy of Sciences (India)

    fer law system generalized irreversible combined refrigeration cycle model with finite-rate heat ...... Chen L, Sun F, Wu C 2004b Optimum allocation of heat exchanger area for refrigeration and air conditioning plants. Appl. Energy 77(3): 339– ...

  18. Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique

    DEFF Research Database (Denmark)

    Franco, Eduardo Batista; da Cunha, Leonardo Fernandes; Herrera, Francyle Simões

    2011-01-01

    Objective. To investigate the accuracy of dies obtained from single-step and 2-step double-mix impressions. Material and Methods. Impressions (n = 10) of a stainless steel die simulating a complete crown preparation were performed using a polyether (Impregum Soft Heavy and Light body) and a vinyl...

  19. Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

    Science.gov (United States)

    Kim, Tae-Gyung; Kim, Sungtae; Lee, Jae-Hoon

    2016-01-01

    The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n = 40). For ICC (Intraoral, CAD/CAM) group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver) machinable alloy were generated. For IC (Intraoral, Cast) group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM) group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast) group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α = 0.05). The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P 0.05). Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions. PMID:28018914

  20. Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

    Directory of Open Access Journals (Sweden)

    Tae-Gyung Kim

    2016-01-01

    Full Text Available The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n=40. For ICC (Intraoral, CAD/CAM group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver machinable alloy were generated. For IC (Intraoral, Cast group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α=0.05. The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P0.05. Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions.

  1. Marginal adaptation of CAD-CAM onlays: Influence of preparation design and impression technique.

    Science.gov (United States)

    Lima, Fernanda Ferruzzi; Neto, Constantino Fernandes; Rubo, José H; Santos, Gildo Coelho; Moraes Coelho Santos, Maria Jacinta

    2018-03-15

    Factors that may affect the marginal adaptation of computer-aided design and computer-aided manufacturing (CAD-CAM) restorations include preparation design, impression technique, and CAD-CAM system. The influence of impression technique and preparation design on CAD-CAM partial coverage restorations has not been fully addressed. The purpose of this in vitro study was to investigate the influence of direct and indirect digital impression techniques and 2 preparation designs on the marginal adaptation of CAD-CAM onlays. Two mesio-occlusal buccal onlay preparations with reduction of the mesiobuccal cusp were made: conventional preparation (CP) with a 1.2-mm modified shoulder margin and modified preparation (MP) flat cuspal reduction without shoulder. Virtual models were generated from each preparation by using a digital scanner (BlueCam; Dentsply Sirona) from the plastic teeth (direct digital impression) or from the stone dies (indirect digital impression). Onlays were designed using a CAD-CAM system (CEREC 4.0; Dentsply Sirona), and nanoceramic resin blocks (Lava Ultimate Restorative; 3M ESPE) were milled using the CEREC MCX milling machine. Marginal discrepancy was evaluated using an optical stereomicroscope at ×25 magnification in 18 locations distributed along the margins of the preparation. The data were analyzed by using 3-way ANOVA followed by the Tukey HSD test (α=.05). CP presented a statistically significant reduced average marginal adaptation (59 ±50 μm) than did MP (69 ±58 μm) (Pmarginal discrepancy in the mesial and buccal locations of MP when compared with CP. Regarding impression techniques, the buccal location presented the smallest average marginal discrepancy in restorations fabricated with indirect impression when compared with direct impression (42 ±33 μm and 60 ±39 μm) (Pmargin presented improved marginal adaptation compared with modified preparation with flat cuspal reduction. Direct and indirect digital impression techniques produced

  2. Students’ Impression towards Science Virtual Test (SVT) on Digestive System Topic

    Science.gov (United States)

    Mahfira, C.; Sanjaya, Y.; Rusyati, L.

    2018-05-01

    During the past few years, technology has significantly support the improvements in assessment.Computer-based test (CBT) comes up as a new type of assessment which offers many benefits. The implementation of computer-based test in term of students’ perspective gives rise to numbers of mixed reactions. Students’ impression is one of the essential things for the implementation of SVT. The purpose of this study was to investigate the impression of students toward SVT. The method used in this research was descriptive method. The participant was 98 students from Junior High School “X” in East Bandung. Students’ impression questionnaire was used as the instrument. There are four aspects tested in this instrument which are students’ experience, technical activity, preference and media of SVT. The result shows that SVT generally gives positive impression to students. Students have a positive experience and did not encounter significant problem when implementing SVT. Students prefer to use SVT and students think the media of SVT is already good.

  3. Citologia de impressão no diagnóstico de infecção corneana por Acanthamoeba: relato de caso Diagnosis of Acanthamoeba corneal infection by impression cytology: case report

    Directory of Open Access Journals (Sweden)

    Jeison de Nadai Barros

    2007-03-01

    Full Text Available Relatamos três casos de infecção corneana por Acanthamoeba sp em que foi possível detectar cistos do microorganismo com a técnica de citologia de impressão. Três pacientes encaminhados ao Laboratório de Doenças Externas Oculares em 2004 com alterações superficiais da córnea foram submetidos ao exame de citologia de impressão para investigação da presença de cistos de Acanthamoeba sp. Duas amostras foram obtidas da córnea de cada paciente e coradas com PAS, hematoxilina e Papanicolaou. Investigação microbiológica de rotina e cultura também foram realizadas após raspado da córnea. O cultivo das amostras e a citologia de impressão foram positivas para Acanthamoeba sp em todos os pacientes, ao passo que os raspados corados com Giemsa foram positivos em dois casos. A citologia de impressão revelou cistos de Acanthamoeba sp entre feixe de células epiteliais corneanas e como células isoladas. Foram observados cistos no epitélio de um dos pacientes com a citologia de impressão após três meses de tratamento, enquanto o raspado foi negativo. No exame anatomopatológico observaram-se cistos no epitélio e estroma de uma córnea receptora de um dos pacientes após transplante. Neste estudo, a citologia de impressão detectou com sucesso cistos de Acanthamoeba sp em pacientes com acometimento epitelial. Por tratar-se de método não invasivo, a técnica pode ser usada para facilitar o diagnóstico mais precoce da infecção por Acanthamoeba, sendo útil também no acompanhamento do tratamento da doença.To describe three cases of corneal infection due to Acanthamoeba sp in which was possible to detect Acanthamoeba sp cysts by the corneal impression cytology technique. Three patients referred to the External Eye Disease Laboratory in 2004 with superficial corneal alterations were submitted to corneal specimen collection by impression cytology filter paper to investigate the presence of Acanthamoeba sp cysts. Two impression

  4. Can physician examiners overcome their first impression when examinee performance changes?

    Science.gov (United States)

    Wood, Timothy J; Pugh, Debra; Touchie, Claire; Chan, James; Humphrey-Murto, Susan

    2018-03-20

    There is an increasing focus on factors that influence the variability of rater-based judgments. First impressions are one such factor. First impressions are judgments about people that are made quickly and are based on little information. Under some circumstances, these judgments can be predictive of subsequent decisions. A concern for both examinees and test administrators is whether the relationship remains stable when the performance of the examinee changes. That is, once a first impression is formed, to what degree will an examiner be willing to modify it? The purpose of this study is to determine the degree that first impressions influence final ratings when the performance of examinees changes within the context of an objective structured clinical examination (OSCE). Physician examiners (n = 29) viewed seven videos of examinees (i.e., actors) performing a physical exam on a single OSCE station. They rated the examinees' clinical abilities on a six-point global rating scale after 60 s (first impression or FIGR). They then observed the examinee for the remainder of the station and provided a final global rating (GRS). For three of the videos, the examinees' performance remained consistent throughout the videos. For two videos, examinee performance changed from initially strong to weak and for two videos, performance changed from initially weak to strong. The mean FIGR rating for the Consistent condition (M = 4.80) and the Strong to Weak condition (M = 4.87) were higher compared to their respective GRS ratings (M = 3.93, M = 2.73) with a greater decline for the Strong to Weak condition. The mean FIGR rating for the Weak to Strong condition was lower (3.60) than the corresponding mean GRS (4.81). This pattern of findings suggests that raters were willing to change their judgments based on examinee performance. Future work should explore the impact of making a first impression judgment explicit versus implicit and the role of context on the

  5. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions

    OpenAIRE

    Ender, Andreas; Attin, Thomas; Mehl, Albert

    2016-01-01

    STATEMENT OF PROBLEM: Digital impression systems have undergone significant development in recent years, but few studies have investigated the accuracy of the technique in vivo, particularly compared with conventional impression techniques. PURPOSE: The purpose of this in vivo study was to investigate the precision of conventional and digital methods for complete-arch impressions. MATERIAL AND METHODS: Complete-arch impressions were obtained using 5 conventional (polyether, POE; vinylsilox...

  6. Irreversible electroporation: state of the art

    Directory of Open Access Journals (Sweden)

    Wagstaff PGK

    2016-04-01

    Full Text Available Peter GK Wagstaff,1 Mara Buijs,1 Willemien van den Bos,1 Daniel M de Bruin,2 Patricia J Zondervan,1 Jean JMCH de la Rosette,1 M Pilar Laguna Pes1 1Department of Urology, 2Department of Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, the Netherlands Abstract: The field of focal ablative therapy for the treatment of cancer is characterized by abundance of thermal ablative techniques that provide a minimally invasive treatment option in selected tumors. However, the unselective destruction inflicted by thermal ablation modalities can result in damage to vital structures in the vicinity of the tumor. Furthermore, the efficacy of thermal ablation intensity can be impaired due to thermal sink caused by large blood vessels in the proximity of the tumor. Irreversible electroporation (IRE is a novel ablation modality based on the principle of electroporation or electropermeabilization, in which electric pulses are used to create nanoscale defects in the cell membrane. In theory, IRE has the potential of overcoming the aforementioned limitations of thermal ablation techniques. This review provides a description of the principle of IRE, combined with an overview of in vivo research performed to date in the liver, pancreas, kidney, and prostate. Keywords: irreversible electroporation, IRE, tumor, ablation, focal therapy, cancer

  7. The use of impression management tactics in structured interviews: a function of question type?

    Science.gov (United States)

    Ellis, Aleksander P J; West, Bradley J; Ryan, Ann Marie; DeShon, Richard P

    2002-12-01

    This study investigated impression management tactic use during structured interviews containing both experience-based and situational questions. Specifically, the authors examined whether applicants' use of impression management tactics depended on question type. Results from 119 structured interviews indicated that almost all of the applicants used some form of impression management. Significantly more assertive than defensive impression management tactics were used, and among assertive tactics, applicants tended to use self-promotion rather than ingratiation. However, different question types prompted the use of different impression management tactics. Ingratiation tactics were used significantly more when applicants answered situational questions, whereas self-promotion tactics were used significantly more when applicants answered experience-based questions. Furthermore, the use of self-promotion and ingratiation tactics was positively related to interviewer evaluations.

  8. Management of the flabby ridge using a modified window technique and polyvinylsiloxane impression material

    Directory of Open Access Journals (Sweden)

    Nawaf Labban

    2018-01-01

    Full Text Available Flabby ridge is a common clinical finding affecting the alveolar ridges of the mandibular or maxillary arches. The anterior region of maxilla is the most affected area in edentulous patients. Dentures on flabby ridges have compromised stability, support, and retention unless adequate measures for its management are employed. Methods applied for flabby ridge management, include surgical removal and augmentation, special impression techniques, balanced distribution of occlusal loads and implant therapy. Special impressions often involve window technique for static impression of flabby area, which present multiple challenges. The purpose of this technique report is to present a modified window technique for the impression of anterior maxillary flabby tissues for improved and controlled application of polyvinylsiloxane impression material that are routinely available in dental practice.

  9. The degree of irreversibility in deterministic finite automata

    DEFF Research Database (Denmark)

    Axelsen, Holger Bock; Holzer, Markus; Kutrib, Martin

    2016-01-01

    the language, and show that the degree induces a strict infinite hierarchy of languages. We examine how the degree of irreversibility behaves under the usual language operations union, intersection, complement, concatenation, and Kleene star, showing tight bounds (some asymptotically) on the degree....

  10. Exergetic efficiency optimization for an irreversible heat pump ...

    Indian Academy of Sciences (India)

    This paper deals with the performance analysis and optimization for irreversible heat pumps working on reversed Brayton cycle with constant-temperature heat reservoirs by taking exergetic efficiency as the optimization objective combining exergy concept with finite-time thermodynamics (FTT). Exergetic efficiency is ...

  11. Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes

    Science.gov (United States)

    2014-01-01

    Background The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Methods Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects’ attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. Results There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Conclusions Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques. PMID:24479892

  12. Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions

    OpenAIRE

    Svanborg, Per; Skjerven, Henrik; Carlsson, Pablo; Eliasson, Alf; Karlsson, Stig; Örtorp, Anders

    2014-01-01

    Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth supported fixed dental prostheses (FDPs) fabricated from digital and conventional impressions. Methods. Ten FDPs were produced from digital impressions using the iTero system and 10 FDPs were produce...

  13. A Sensitive Measurement for Estimating Impressions of Image-Contents

    Science.gov (United States)

    Sato, Mie; Matouge, Shingo; Mori, Toshifumi; Suzuki, Noboru; Kasuga, Masao

    We have investigated Kansei Content that appeals maker's intention to viewer's kansei. An SD method is a very good way to evaluate subjective impression of image-contents. However, because the SD method is performed after subjects view the image-contents, it is difficult to examine impression of detailed scenes of the image-contents in real time. To measure viewer's impression of the image-contents in real time, we have developed a Taikan sensor. With the Taikan sensor, we investigate relations among the image-contents, the grip strength and the body temperature. We also explore the interface of the Taikan sensor to use it easily. In our experiment, a horror movie is used that largely affects emotion of the subjects. Our results show that there is a possibility that the grip strength increases when the subjects view a strained scene and that it is easy to use the Taikan sensor without its circle base that is originally installed.

  14. Peptide Drug Release Behavior from Biodegradable Temperature-Responsive Injectable Hydrogels Exhibiting Irreversible Gelation

    Directory of Open Access Journals (Sweden)

    Kazuyuki Takata

    2017-10-01

    Full Text Available We investigated the release behavior of glucagon-like peptide-1 (GLP-1 from a biodegradable injectable polymer (IP hydrogel. This hydrogel shows temperature-responsive irreversible gelation due to the covalent bond formation through a thiol-ene reaction. In vitro sustained release of GLP-1 from an irreversible IP formulation (F(P1/D+PA40 was observed compared with a reversible (physical gelation IP formulation (F(P1. Moreover, pharmaceutically active levels of GLP-1 were maintained in blood after subcutaneous injection of the irreversible IP formulation into rats. This system should be useful for the minimally invasive sustained drug release of peptide drugs and other water-soluble bioactive reagents.

  15. Accuracy of a reformulated fast-set vinyl polysiloxane impression material using dual-arch trays.

    Science.gov (United States)

    Kang, Alex H; Johnson, Glen H; Lepe, Xavier; Wataha, John C

    2009-05-01

    A common technique used for making crown impressions involves use of a vinyl polysiloxane impression material in combination with a dual-arch tray. A leading dental manufacturer has reformulated its vinyl polysiloxane (VPS) impression line, but the accuracy of the new material has not been verified. The purpose of this study was to assess the accuracy of reformulated VPS impression materials using the single-step dual-arch impression technique. Dual-arch impressions were made on a typodont containing a master stainless steel standard crown preparation die, from which gypsum working dies were formed, recovered, and measured. The impression materials evaluated were Imprint 3 Penta Putty with Quick Step Regular Body (IP-0); Imprint 3 Penta Quick Step Heavy Body with Quick Step Light Body (IP-1); Aquasil Ultra Rigid Fast Set with LV Fast Set (AQ-1); and Aquasil Ultra Heavy Fast Set with XLV Fast Set (AQ-2) (n=10). All impressions were disinfected with CaviCide spray for 10 minutes prior to pouring with type IV gypsum. Buccolingual (BL), mesiodistal (MD), and occlusogingival (OG) dimensions were measured and compared to the master die using an optical measuring microscope. Linear dimensional change was also assessed for IP-0 and AQ-1 at 1 and 24 hours based on ANSI/ADA Specification No. 19. Single-factor ANOVA with Dunnett's T3 multiple comparisons was used to compare BL, MD, and OG changes, with hypothesis testing at alpha=.05. A repeated-measures ANOVA was used to compare linear dimensional changes. There were statistical differences among the 4 impression systems for 3 of 4 dimensions of the master die. IP-0 working dies were significantly larger in MD and OG-L dimensions but significantly smaller in the BL dimension. IP-1 working dies were significantly smaller in the BL dimension compared to the master die. With the exception of IP-0, differences detected were small and clinically insignificant. No significant differences were observed for linear dimensional change

  16. Application of neutral electrolyzed water to disinfection of alginate impression.

    Science.gov (United States)

    Nagamatsu, Yuki; Chen, Ker-Kong; Nagamatsu, Hiroshi; Kozono, Yoshio; Shimizu, Hiroshi

    2016-01-01

    Neutral electrolyzed water was developed with new concepts of long-term good durability and minimum corrosiveness to metal in addition to its excellent bactericidal activities similar to acid type of electrolyzed waters. The present study examined the bactericidal effects of the neutral electrolyzed water on disinfection of the alginate impression of a dental arch model contaminated by bacteria. Only 1-min immersion in neutral electrolyzed water could sufficiently disinfect the alginate impression including the metallic tray under ultrasonic with no significant differences from acid electrolyzed waters. No bactericidal effects were found in any electrolyzed water when used as mixing water. Considering the advantages and disadvantages of each electrolyzed water in a comprehensive way, it was suggested that neutral electrolyzed water may be the most appropriate for the disinfection of alginate impression.

  17. Cancer patients and positive sensory impressions in the hospital environment

    DEFF Research Database (Denmark)

    Timmermann, Connie; Uhrenfeldt, Lisbeth; Birkelund, Regner

    2013-01-01

    This study explores how cancer patients experience the meaning of positive sensory impressions in the hospital environment such as architecture, decoration and the interior. Data were obtained at a general hospital in Denmark by interviewing six cancer patients at two different wards. The analysis...... process was guided by the hermeneutical–phenomenological theory of interpretation as presented by the French philosopher Paul Ricoeur. Two main themes were identified: to preserve identity and positive thoughts and feelings. The participants experienced that positive sensory impressions in the hospital...... to recall some of their feelings of identity. This paper adds knowledge about how cancer patients experience sensory impressions in the hospital environment. An environment that provides homeliness and offers a view to nature seems to help some patients to preserve their identity. Furthermore, positive...

  18. Dimensional changes of alginate impression by using perforated and non-perforated ring trays

    Directory of Open Access Journals (Sweden)

    Sumadhi Sastrodihardjo

    2010-03-01

    Full Text Available Dimensional changes are a common occurrence in impressions, either during or after impression taking. It produces a difference in the dimensions of the object and the model, which leads to the restoration being ill-fitted. Several causal factors have been proposed such as friction between the impression material and the teeth, the bulk of the impression material, the type of impression materials used, the impression technique, the pouring time and many others. The exact causal factor is still unknown and the dimensional change mechanism is still poorly understood. The objective of this research was to investigate the role of the perforation on the ring trays in producing dimensional changes in the impression by using perforated and non-perforated ring trays. Alginate impressions were made on the frustum of cone metal master die with a 7.08 mm base diameter, 7.03 mm top diameter and 9.23 mm height using perforated and non-perforated ring trays with 9.40 mm in diameter and 14.17 mm in height. The dimensional change was determined by comparing the dimension of the dental stone die and its metal master die. The results showed that the percentage of dimensional changes that occurred by using perforated ring tray were (+ 0.56±0.40 on the top area, (- 3.54±2.92 on base area and (+ 1.54±0.83 in height, respectively. As compared to using non-perforated ring trays, the percentage of dimensional changes that occurred were (- 0.49±0.49 on top area, (- 8.76±3.95 on base area and (+ 1.19±0.71 in height, respectively. There was a significant difference in the direction of the dimensional changes on both the top areas, but not in the base areas and height.

  19. Development and psychometric evaluation of a clinical global impression for schizoaffective disorder scale.

    Science.gov (United States)

    Allen, Michael H; Daniel, David G; Revicki, Dennis A; Canuso, Carla M; Turkoz, Ibrahim; Fu, Dong-Jing; Alphs, Larry; Ishak, K Jack; Bartko, John J; Lindenmayer, Jean-Pierre

    2012-01-01

    The Clinical Global Impression for Schizoaffective Disorder scale is a new rating scale adapted from the Clinical Global Impression scale for use in patients with schizoaffective disorder. The psychometric characteristics of the Clinical Global Impression for Schizoaffective Disorder are described. Content validity was assessed using an investigator questionnaire. Inter-rater reliability was determined with 12 sets of videotaped interviews rated independently by two trained individuals. Test-retest reliability was assessed using 30 randomly selected raters from clinical trials who evaluated the same videos on separate occasions two weeks apart. Convergent and divergent validity and effect size were evaluated by comparing scores between the Clinical Global Impression for Schizoaffective Disorder and the Positive and Negative Syndrome Scale, 21-item Hamilton Rating Scale for Depression, and Young Mania Rating Scale scales using pooled patient data from two clinical trials. Clinical Global Impression for Schizoaffective Disorder scores were then linked to corresponding Positive and Negative Syndrome Scale scores. Content validity was strong. Inter-rater agreement was good to excellent for most scales and subscales (intra-class correlation coefficient ≥ 0.50). Test-retest showed good reproducibility, with intraclass correlation coefficients ranging from 0.444 to 0.898. Spearman correlations between Clinical Global Impression for Schizoaffective Disorder domains and corresponding symptom scales were 0.60 or greater, and effect sizes for Clinical Global Impression for Schizoaffective Disorder overall and domain scores were similar to Positive and Negative Syndrome Scale Young Mania Rating Scale, and 21-item Hamilton Rating Scale for Depression scores. Raters anticipated that the scale might be less effective in distinguishing negative from depressive symptoms, and, in fact, the results here may reflect that clinical reality. Multiple lines of evidence support the

  20. Self-presentational persona: simultaneous management of multiple impressions.

    Science.gov (United States)

    Leary, Mark R; Allen, Ashley Batts

    2011-11-01

    Most research on self-presentation has examined how people convey images of themselves on only 1 or 2 dimensions at a time. In everyday interactions, however, people often manage their impressions on several image-relevant dimensions simultaneously. By examining people's self-presentations to several targets across multiple dimensions, these 2 studies offer new insights into the nature of self-presentation and provide a novel paradigm for studying impression management. Results showed that most people rely on a relatively small number of basic self-presentational personas in which they convey particular profiles of impressions as a set and that these personas reflect both normative influences to project images that are appropriate to a particular target and distinctive influences by which people put an idiosyncratic spin on these normative images. Furthermore, although people's self-presentational profiles correlate moderately with their self-views, they tailor their public images to specific targets. The degree to which participants' self-presentations were normative and distinctive, as well as the extent to which they reflected their own self-views, were moderated by individual differences in agreeableness, self-esteem, authenticity, and Machiavellianism.

  1. Irreversible denaturation of maltodextrin glucosidase studied by differential scanning calorimetry, circular dichroism, and turbidity measurements.

    Science.gov (United States)

    Goyal, Megha; Chaudhuri, Tapan K; Kuwajima, Kunihiro

    2014-01-01

    Thermal denaturation of Escherichia coli maltodextrin glucosidase was studied by differential scanning calorimetry, circular dichroism (230 nm), and UV-absorption measurements (340 nm), which were respectively used to monitor heat absorption, conformational unfolding, and the production of solution turbidity. The denaturation was irreversible, and the thermal transition recorded at scan rates of 0.5-1.5 K/min was significantly scan-rate dependent, indicating that the thermal denaturation was kinetically controlled. The absence of a protein-concentration effect on the thermal transition indicated that the denaturation was rate-limited by a mono-molecular process. From the analysis of the calorimetric thermograms, a one-step irreversible model well represented the thermal denaturation of the protein. The calorimetrically observed thermal transitions showed excellent coincidence with the turbidity transitions monitored by UV-absorption as well as with the unfolding transitions monitored by circular dichroism. The thermal denaturation of the protein was thus rate-limited by conformational unfolding, which was followed by a rapid irreversible formation of aggregates that produced the solution turbidity. It is thus important to note that the absence of the protein-concentration effect on the irreversible thermal denaturation does not necessarily means the absence of protein aggregation itself. The turbidity measurements together with differential scanning calorimetry in the irreversible thermal denaturation of the protein provided a very effective approach for understanding the mechanisms of the irreversible denaturation. The Arrhenius-equation parameters obtained from analysis of the thermal denaturation were compared with those of other proteins that have been reported to show the one-step irreversible thermal denaturation. Maltodextrin glucosidase had sufficiently high kinetic stability with a half-life of 68 days at a physiological temperature (37°C).

  2. Rethinking Social Desirability Scales: From Impression Management to Interpersonally Oriented Self-Control.

    Science.gov (United States)

    Uziel, Liad

    2010-05-01

    Social desirability (specifically, impression management) scales are widely used by researchers and practitioners to screen individuals who bias self-reports in a self-favoring manner. These scales also serve to identify individuals at risk for psychological and health problems. The present review explores the evidence with regard to the ability of these scales to achieve these objectives. In the first part of the review, I present six criteria to evaluate impression management scales and conclude that they are unsatisfactory as measures of response style. Next, I explore what individual differences in impression management scores actually do measure. I compare two approaches: a defensiveness approach, which argues that these scales measure defensiveness that stems from vulnerable self-esteem, and an adjustment approach, which suggests that impression management is associated with personal well-being and interpersonal adjustment. Data from a wide variety of fields including social behavior, affect and well-being, health, and job performance tend to favor the adjustment approach. Finally, I argue that scales measuring impression management should be redefined as measures of interpersonally oriented self-control that identify individuals who demonstrate high levels of self-control, especially in social contexts. © The Author(s) 2010.

  3. Anesthetic Efficacy in Irreversible Pulpitis: A Randomized Clinical Trial.

    Science.gov (United States)

    Allegretti, Carlos E; Sampaio, Roberta M; Horliana, Anna C R T; Armonia, Paschoal L; Rocha, Rodney G; Tortamano, Isabel Peixoto

    2016-01-01

    Inferior alveolar nerve block has a high failure rate in the treatment of mandibular posterior teeth with irreversible pulpitis. The aim of this study was to compare the anesthetic efficacy of 4% articaine, 2% lidocaine and 2% mepivacaine, all in combination with 1:100,000 epinephrine, in patients with irreversible pulpitis of permanent mandibular molars during a pulpectomy procedure. Sixty-six volunteers from the Emergency Center of the School of Dentistry, University of São Paulo, randomly received 3.6 mL of local anesthetic as a conventional inferior alveolar nerve block (IANB). The subjective signal of lip numbness, pulpal anesthesia and absence of pain during the pulpectomy procedure were evaluated respectively, by questioning the patient, stimulation using an electric pulp tester and a verbal analogue scale. All patients reported the subjective signal of lip numbness. Regarding pulpal anesthesia success as measured with the pulp tester, the success rate was respectively 68.2% for mepivacaine, 63.6% for articaine and 63.6% for lidocaine. Regarding patients who reported no pain or mild pain during the pulpectomy, the success rate was, respectively 72.7% for mepivacaine, 63.6% for articaine and 54.5% for lidocaine. These differences were not statistically significant. Neither of the solutions resulted in 100% anesthetic success in patients with irreversible pulpitis of mandibular molars.

  4. Managing Impression Formation in Computer-Mediated Communication.

    Science.gov (United States)

    Liu, Yuliang; Ginther, Dean

    2001-01-01

    Offers suggestions for online instructors regarding verbal and nonverbal impression management. The recommendations should facilitate computer mediated teacher-student or manager-client interactions and help develop constructive relationships that promote learning and productivity. (EV)

  5. A Paradigm shift in the concept for making dental impressions

    OpenAIRE

    Nayar, Sanjna; Mahadevan, R.

    2015-01-01

    Digital dental impression is a revolutionary technological advancement that so surpasses the accuracy and efficiency of former techniques for obtaining replicas of prepared teeth for the purpose of fabricating restorations that its adoption by dentists is rapidly eclipsing the use of elastomeric impression materials. The ultimate goals of dentists dedicated to quality restorative dentistry are to make their treatment of patients as accurate, stressless, and efficient as possible. By eliminati...

  6. Performance of dental impression materials: Benchmarking of materials and techniques by three-dimensional analysis.

    Science.gov (United States)

    Rudolph, Heike; Graf, Michael R S; Kuhn, Katharina; Rupf-Köhler, Stephanie; Eirich, Alfred; Edelmann, Cornelia; Quaas, Sebastian; Luthardt, Ralph G

    2015-01-01

    Among other factors, the precision of dental impressions is an important and determining factor for the fit of dental restorations. The aim of this study was to examine the three-dimensional (3D) precision of gypsum dies made using a range of impression techniques and materials. Ten impressions of a steel canine were fabricated for each of the 24 material-method-combinations and poured with type 4 die stone. The dies were optically digitized, aligned to the CAD model of the steel canine, and 3D differences were calculated. The results were statistically analyzed using one-way analysis of variance. Depending on material and impression technique, the mean values had a range between +10.9/-10.0 µm (SD 2.8/2.3) and +16.5/-23.5 µm (SD 11.8/18.8). Qualitative analysis using colorcoded graphs showed a characteristic location of deviations for different impression techniques. Three-dimensional analysis provided a comprehensive picture of the achievable precision. Processing aspects and impression technique were of significant influence.

  7. The Trouble with Applicant Impression Management.

    Science.gov (United States)

    Ralston, Steven M.; Kirkwood, William G.

    1999-01-01

    Suggests that applicant impression management (AIM) is more harmful to employment interviewing than is currently suspected. Offers a conceptual model of AIM that is consistent with employment interviewing practice. Presents and critiques three arguments used to defend AIM. Examines a model for helping employers conduct interviews that minimize the…

  8. Sample size effect on the determination of the irreversibility line of high-Tc superconductors

    International Nuclear Information System (INIS)

    Li, Q.; Suenaga, M.; Li, Q.; Freltoft, T.

    1994-01-01

    The irreversibility lines of a high-J c superconducting Bi 2 Sr 2 Ca 2 Cu 3 O x /Ag tape were systematically measured upon a sequence of subdivisions of the sample. The irreversibility field H r (T) (parallel to the c axis) was found to change approximately as L 0.13 , where L is the effective dimension of the superconducting tape. Furthermore, it was found that the irreversibility line for a grain-aligned Bi 2 Sr 2 Ca 2 Cu 3 O x specimen can be approximately reproduced by the extrapolation of this relation down to a grain size of a few tens of micrometers. The observed size effect could significantly obscure the real physical meaning of the irreversibility lines. In addition, this finding surprisingly indicated that the Bi 2 Sr 2 Ca 2 Cu 2 O x /Ag tape and grain-aligned specimen may have similar flux line pinning strength

  9. Dispositional malevolence and impression formation: Dark Tetrad associations with accuracy and positivity in first impressions.

    Science.gov (United States)

    Rogers, Katherine H; Le, Marina T; Buckels, Erin E; Kim, Mikayla; Biesanz, Jeremy C

    2018-02-19

    The Dark Tetrad traits (subclinical psychopathy, narcissism, Machiavellianism, and everyday sadism) have interpersonal consequences. At present, however, how these traits are associated with the accuracy and positivity of first impressions is not well understood. The present article addresses three primary questions. First, to what extent are perceiver levels of Dark Tetrad traits associated with differing levels of perceptive accuracy? Second, to what extent are target levels of Dark Tetrad traits associated with differing levels of expressive accuracy? Finally, to what extent can Dark Tetrad traits be differentiated when examining perceptions of and by others? In a round-robin design, undergraduate participants (N = 412) in small groups engaged in brief, naturalistic, unstructured dyadic interactions before providing impressions of their partner. Dark Tetrad traits were associated with being viewed and viewing others less distinctively accurately and more negatively. Interpersonal perceptions that included an individual scoring highly on one of the Dark Tetrad traits differed in important ways from interactions among individuals with more benevolent personalities. Notably, despite the similarities between the Dark Tetrad, traits had unique associations with interpersonal perceptions. © 2018 Wiley Periodicals, Inc.

  10. Clinical evaluation of the efficacy of removing microorganisms to disinfect patient-derived dental impressions.

    Science.gov (United States)

    Egusa, Hiroshi; Watamoto, Takao; Matsumoto, Takuya; Abe, Keiko; Kobayashi, Munemasa; Akashi, Yoshihiro; Yatani, Hirofumi

    2008-01-01

    Disinfection of dental impressions is an indispensable procedure for the control of cross-contamination; however, there is limited information on the efficacy of disinfection under clinical conditions. The objective of this study was to clinically evaluate the disinfection efficacy of commercially available agents in removing oral pathogens from patient-derived impressions. Impressions from 54 patients were divided into groups and either left undisinfected or underwent 1 of 5 disinfection treatments: (1) 2% glutaraldehyde (GA), (2) 1% sodium hypochlorite (SH), (3) 0.25% benzalkonium chloride (BC), (4) 1 ppm ozonated water (OW), or (5) the Hygojet/MD520 system (HJ). An impression culture technique using a brain heart infusion agar medium was used to visualize the microbial contamination on the surface of the impression cultures. The persistent presence of oral pathogens on the impression cultures was examined using selective isolation agar plates. The isolation frequencies of streptococci, staphylococci, Candida, methicillin-resistant Staphylococcus aureus, and Pseudomonas aeruginosa species from undisinfected impressions were 100%, 55.6%, 25.9%, 25.9% and 5.6%, respectively. Disinfection with HJ and BC removed the microorganisms with the greatest efficacy, followed by GA, SH, and OW. Potential bacterial contamination could be detected even after disinfection had been performed. Combined use of BC plus GA or SH removed oral pathogens almost completely from dental impressions. This investigation showed that potential contaminants are still present, even after general disinfection procedures. Therefore, either HJ or the combined use of BC with GA or SH is recommended for clinical and laboratory use.

  11. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions.

    Science.gov (United States)

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin; Hwang, Hyeon-Shik

    2016-05-01

    To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

  12. Use of digital photography in the reconstruction of the occlusal plane orientation

    Directory of Open Access Journals (Sweden)

    Robert Antonić,

    2009-08-01

    Full Text Available Aim This study evaluated whether the occlusal plane measurementson digital photographs were reliable for the reconstructionof occlusal plane.Methods Forty-two subjects (25 female and 17 male subjects,aged 19 to 30 years with all teeth and Angle Class I participated.Irreversible hydrocolloid impressions were made and the castswere poured in dental stone (ISO Type I and finally mounted inthe S.A.M. 2 “P”, articulator (S.A.M. Praezisiontechnik, GmbH,Munich, Germany by a quick mount face-bow transfer. Lateraldigital photographs were taken from a distance of 1.5 m in a naturalhead position with a subject in erect posture. A Fox plane wasplaced over the maxillary dental arch. A quick-mounting face-bowwas positioned. The angles between the articulator horizontalplane and the occlusal plane (AHP-OP, as well as those betweenthe face bow and the Fox plane (FB-FP were measured, and thesignificance of the difference between the means was tested by thet-test (p<0.05.Results The mean value of AHP-OP angle was 8.56 ± 3.1 degreesand the mean value of FB-FP angle was 8.80 ± 4.2 degrees. Therewas no significant difference between the male and the female subjects(p<0.05. There was no significant difference between AHPOPand FB-FP angles (p<0.05.Conclusion Measurements of occlusal plane inclination fromdigital photographs could be helpful in future prosthodontic reconstructiontreatment.

  13. Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection.

    Science.gov (United States)

    Kamble, Suresh S; Khandeparker, Rakshit Vijay; Somasundaram, P; Raghav, Shweta; Babaji, Rashmi P; Varghese, T Joju

    2015-09-01

    Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method. The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures. Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes. The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.

  14. A Simplified Technique for Implant-Abutment Level Impression after Soft Tissue Adaptation around Provisional Restoration

    Science.gov (United States)

    Kutkut, Ahmad; Abu-Hammad, Osama; Frazer, Robert

    2016-01-01

    Impression techniques for implant restorations can be implant level or abutment level impressions with open tray or closed tray techniques. Conventional implant-abutment level impression techniques are predictable for maximizing esthetic outcomes. Restoration of the implant traditionally requires the use of the metal or plastic impression copings, analogs, and laboratory components. Simplifying the dental implant restoration by reducing armamentarium through incorporating conventional techniques used daily for crowns and bridges will allow more general dentists to restore implants in their practices. The demonstrated technique is useful when modifications to implant abutments are required to correct the angulation of malpositioned implants. This technique utilizes conventional crown and bridge impression techniques. As an added benefit, it reduces costs by utilizing techniques used daily for crowns and bridges. The aim of this report is to describe a simplified conventional impression technique for custom abutments and modified prefabricated solid abutments for definitive restorations. PMID:29563457

  15. A Simplified Technique for Implant-Abutment Level Impression after Soft Tissue Adaptation around Provisional Restoration

    Directory of Open Access Journals (Sweden)

    Ahmad Kutkut

    2016-05-01

    Full Text Available Impression techniques for implant restorations can be implant level or abutment level impressions with open tray or closed tray techniques. Conventional implant-abutment level impression techniques are predictable for maximizing esthetic outcomes. Restoration of the implant traditionally requires the use of the metal or plastic impression copings, analogs, and laboratory components. Simplifying the dental implant restoration by reducing armamentarium through incorporating conventional techniques used daily for crowns and bridges will allow more general dentists to restore implants in their practices. The demonstrated technique is useful when modifications to implant abutments are required to correct the angulation of malpositioned implants. This technique utilizes conventional crown and bridge impression techniques. As an added benefit, it reduces costs by utilizing techniques used daily for crowns and bridges. The aim of this report is to describe a simplified conventional impression technique for custom abutments and modified prefabricated solid abutments for definitive restorations.

  16. Effects of Aging on General and Specific Memory for Impressions

    Directory of Open Access Journals (Sweden)

    Megan J. Limbert

    2018-05-01

    Full Text Available Despite the number of documented declines in memory with age, memory for socioemotional information can be preserved into older adulthood. These studies assessed whether memory for character information could be preserved with age, and how the general versus specific nature of the information tested affected outcomes. We hypothesized that memory for general impressions would be preserved with age, but that memory for specific details would be impaired. In two experiments, younger and older adults learned character information about individuals characterized as positive, neutral, or negative. Participants then retrieved general impressions and specific information for each individual. The testing conditions in Experiment 2 discouraged deliberate recall. In Experiment 1, we found that younger performed better than older adults on both general and specific memory measures. Although age differences in memory for specific information persisted in Experiment 2, we found that younger and older adults remembered general impressions to a similar extent when testing conditions encouraged the use of “gut impressions” rather than deliberate retrieval from memory. We conclude that aging affects memory for specific character information, but memory for general impressions can be age-equivalent. Furthermore, there is no evidence for a positivity bias or differences in the effects of valence on memory across the age groups.

  17. Irreversible absorption heat-pump and its optimal performance

    International Nuclear Information System (INIS)

    Chen Lingen; Qin Xiaoyong; Sun Fengrui; Wu Chih

    2005-01-01

    On the basis of an endoreversible absorption heat-pump cycle, a generalized irreversible four-heat-reservoir absorption heat-pump cycle model is established by taking account of the heat resistances, heat leak and irreversibilities due to the internal dissipation of the working substance. The heat transfer between the heat reservoir and the working substance is assumed to obey the linear (Newtonian) heat-transfer law, and the overall heat-transfer surface area of the four heat-exchangers is assumed to be constant. The fundamental optimal relations between the coefficient of performance (COP) and the heating-load, the maximum COP and the corresponding heating-load, the maximum heating load and the corresponding COP, as well as the optimal temperatures of the working substance and the optimal heat-transfer surface areas of the four heat-exchangers are derived by using finite-time thermodynamics. Moreover, the effects of the cycle parameters on the characteristics of the cycle are studied by numerical examples

  18. White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions.

    Science.gov (United States)

    Jeon, Jin-Hun; Lee, Kyung-Tak; Kim, Hae-Young; Kim, Ji-Hwan; Kim, Woong-Chul

    2013-11-01

    The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (α=.05). The discrepancy between the impressions for the canine, premolar, and molar teeth were 6.3 µm (95% confidence interval [CI], 5.4-7.2), 6.4 µm (95% CI, 5.3-7.6), and 8.9 µm (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: 26.7 µm (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, 16.3 µm (95% CI, 15.3-17.3), and 14.0 µm (95% CI, 12.3-15.7), respectively. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between 6.3 µm and 8.9 µm, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

  19. Quantum mechanical irreversibility and measurement

    CERN Document Server

    Grigolini, P

    1993-01-01

    This book is intended as a tutorial approach to some of the techniques used to deal with quantum dissipation and irreversibility, with special focus on their applications to the theory of measurements. The main purpose is to provide readers without a deep expertise in quantum statistical mechanics with the basic tools to develop a critical judgement on whether the major achievements in this field have to be considered a satisfactory solution of quantum paradox, or rather this ambitious achievement has to be postponed to when a new physics, more general than quantum and classical physics, will

  20. Subjective relevance of objective measures for spatial impression (A)

    DEFF Research Database (Denmark)

    Wang, Lily M.; Gade, Anders Christian

    2000-01-01

    Several objective measures have been proposed to describe the feeling of spatial impression in concert halls, including Lateral Energy Fraction (LF) and Interaural Cross-Correlation Coefficient (IACC). However, previous studies have shown that LF and IACC values did not highly correlate with each...... other at individual seat positions in real halls [J. S. Bradley, J. Acoust. Soc. Am. 96, 3525–3535 (1994)]. To investigate the listener envelopment aspect of spatial impression further, subjective paired-comparison tests have been run using signals which have various values for LF, early IACC (from 5...

  1. Lasting Impressions: Hannah Arendt's Educational Legacy

    Science.gov (United States)

    Gardiner, Rita A.

    2016-01-01

    Hannah Arendt's work is gaining increasing recognition in educational administration. But less has been written about her as an educator, colleague, and provocateur. Here, I explore the lasting impressions that Arendt had on former students, colleagues, and friends. This exploration is conducted through the lens of Arendtian narrative inquiry. For…

  2. Digital versus conventional implant impressions for partially edentulous arches: An evaluation of accuracy.

    Science.gov (United States)

    Marghalani, Amin; Weber, Hans-Peter; Finkelman, Matthew; Kudara, Yukio; El Rafie, Khaled; Papaspyridakos, Panos

    2018-04-01

    To the authors' knowledge, while accuracy outcomes of the TRIOS scanner have been compared with conventional impressions, no available data are available regarding the accuracy of digital scans with the Omnicam and True Definition scanners versus conventional impressions for partially edentulous arches. The purpose of this in vitro study was to compare the accuracy of digital implant scans using 2 different intraoral scanners (IOSs) with that of conventional impressions for partially edentulous arches. Two partially edentulous mandibular casts with 2 implant analogs with a 30-degree angulation from 2 different implant systems (Replace Select RP; Nobel Biocare and Tissue level RN; Straumann) were used as controls. Sixty digital models were made from these 2 definitive casts in 6 different groups (n=10). Splinted implant-level impression procedures followed by digitization were used to produce the first 2 groups. The next 2 groups were produced by digital scanning with Omnicam. The last 2 groups were produced by digital scanning with the True Definition scanner. Accuracy was evaluated by superimposing the digital files of each test group onto the digital file of the controls with inspection software. The difference in 3-dimensional (3D) deviations (median ±interquartile range) among the 3 impression groups for Nobel Biocare was statistically significant among all groups (P3D deviations among the 3 impression groups for Straumann was statistically significant among all groups (P=.003), except for the conventional impression (22 ±5 μm) and True Definition (17 ±5 μm) groups; the median ±interquartile range for the Omnicam group was 26 ±15 μm. The difference in 3D deviations between the 2 implant systems was significant for the Omnicam (P=.011) and conventional (Pimpression techniques but not for the True Definition technique (P=.247). Within the limitations of this study, both the impression technique and the implant system affected accuracy. The True

  3. Impression Management in Social Media: The Example of LinkedIn

    OpenAIRE

    Joanna Paliszkiewicz; Magdalena Madra-Sawicka

    2016-01-01

    Nowadays, the relationships are often initiated and maintained in online environments, the formation and management of online impressions have gained importance and become the subject of numerous studies. The impression management is a conscious process in which people attempt to influence the perceptions of their image. They do it by controlling and managing information presented in social media. The presentation of identity is the key to success or failure for example i...

  4. Physical properties and compatibility with dental stones of current alginate impression materials.

    Science.gov (United States)

    Murata, H; Kawamura, M; Hamada, T; Chimori, H; Nikawa, H

    2004-11-01

    This study examined physical properties and compatibility with dental stones of two types of alginate impression materials. Five powder-type alginate impression materials (Alginoplast EM, Aroma Fine, Algiace Z, Coe Alginate, Jeltrate Plus) and a paste-type alginate impression material (Tokuso AP-1) were used. The dynamic viscosity immediately after mixing was measured by means of a controlled-stress rheometer. The gelation times were determined according to Japanese Industrial Standards (JIS) T6505, and recovery from deformation, strain in compression and compressive strength were determined according to the International Organization for Standardization (ISO) specification 1563. Detail reproduction and surface roughness of type III dental stones (New Plastone, New Sunstone) and a type IV dental stone (Die Stone) were evaluated using a ruled test block as specified in the ISO specification 1563 and a profilometer, respectively. The alginate impression materials evaluated in this study were all in compliance with the ISO specification 1563 and JIS T6505. The alginate impression materials had similar mechanical properties after gelation, whilst a wide range of dynamic viscosity immediately after being mixed, gelation times and compatibility with dental stones were found among the materials. The paste-type material had a higher dynamic viscosity and a shorter gelation time than the powder-type materials. The best surface quality was obtained with the paste-type material/type III dental stone cast combinations. The materials should be selected in consideration of initial flow, setting characteristics and compatibility with dental stones. The results suggested that a paste-type material would better meet the requirements of an alginate impression material.

  5. Effects of immersion disinfection of agar-alginate combined impressions on the surface properties of stone casts.

    Science.gov (United States)

    Iwasaki, Yukiko; Hiraguchi, Hisako; Iwasaki, Eriko; Yoneyama, Takayuki

    2016-01-01

    This study investigated the effects of disinfection of agar-alginate combined impressions on the surface properties of the resulting stone casts. Two brands of cartridge-form agar impression material and one alginate impression material were used. Agar-alginate combined impressions of smooth glass plates were prepared. The impressions were immersed in 0.55% ortho-phthalaldehyde solution or 0.5% sodium hypochlorite solution for 1, 3, 5 and 10 min. A stone cast made with an impression that had not been immersed was prepared as a control. The surface roughness (Ra) of the stone casts was measured, and the cast surfaces were observed by SEM. Immersion of agar-alginate combined impressions in 0.5% sodium hypochlorite solution for up to 10 min had no serious adverse effects on the surface properties of the stone casts. In contrast, even 1 min of immersion in 0.55% ortho-phthalaldehyde solution caused deterioration of the cast surface properties.

  6. Reversing the irreversible: From limit cycles to emergent time symmetry

    Science.gov (United States)

    Cortês, Marina; Smolin, Lee

    2018-01-01

    In 1979 Penrose hypothesized that the arrows of time are explained by the hypothesis that the fundamental laws are time irreversible [R. Penrose, in General Relativity: An Einstein Centenary Survey (1979)]. That is, our reversible laws, such as the standard model and general relativity are effective, and emerge from an underlying fundamental theory which is time irreversible. In [M. Cortês and L. Smolin, Phys. Rev. D 90, 084007 (2014), 10.1103/PhysRevD.90.084007; 90, 044035 (2014), 10.1103/PhysRevD.90.044035; 93, 084039 (2016), 10.1103/PhysRevD.93.084039] we put forward a research program aiming at realizing just this. The aim is to find a fundamental description of physics above the Planck scale, based on irreversible laws, from which will emerge the apparently reversible dynamics we observe on intermediate scales. Here we continue that program and note that a class of discrete dynamical systems are known to exhibit this very property: they have an underlying discrete irreversible evolution, but in the long term exhibit the properties of a time reversible system, in the form of limit cycles. We connect this to our original model proposal in [M. Cortês and L. Smolin, Phys. Rev. D 90, 084007 (2014), 10.1103/PhysRevD.90.084007], and show that the behaviors obtained there can be explained in terms of the same phenomenon: the attraction of the system to a basin of limit cycles, where the dynamics appears to be time reversible. Further than that, we show that our original models exhibit the very same feature: the emergence of quasiparticle excitations obtained in the earlier work in the space-time description is an expression of the system's convergence to limit cycles when seen in the causal set description.

  7. Nonequilibrium and irreversibility

    CERN Document Server

    Gallavotti, Giovanni

    2014-01-01

    This book concentrates on the properties of the stationary states in chaotic systems of particles or fluids, leaving aside the theory of the way they can be reached. The stationary states of particles or of fluids (understood as probability distributions on microscopic configurations or on the fields describing continua) have received important new ideas and data from numerical simulations and reviews are needed. The starting point is to find out which time invariant distributions come into play in physics. A special feature of this book is the historical approach. To identify the problems the author analyzes the papers of the founding fathers Boltzmann, Clausius and Maxwell including translations of the relevant (parts of ) historical documents. He also establishes a close link between treatment of irreversible phenomena in statistical mechanics and the theory of chaotic systems at and beyond the onset of turbulence as developed by Sinai, Ruelle, Bowen (SRB) and others: the author gives arguments intending t...

  8. Investment Irreversibility and Precautionary Savings in General Equilibrium

    DEFF Research Database (Denmark)

    Ejarque, João

    than irreversibility effects. If shocks are idiosyncratic and affect a cross section of agents over capital, an increase in their variance may induce an increase in aggregate investment even if all agents have an incentive to invest less, because zero investment is now an active lower bound for part...

  9. Impression Management in the Ethical Self-Presentation of Offenders Undergoing Presentence Evaluation

    Science.gov (United States)

    Holland, Terrill R.; Boik, Robert J.

    1978-01-01

    Ethical choices were assessed for offenders instructed to produce favorable versus unfavorable impressions. Pronounced impression management effects were obtained for prosocial and antisocial responses, and high scores on a dimension of change defined by these variables were related to sociopathic features on the MMPI. (Author)

  10. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

    Science.gov (United States)

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin

    2016-01-01

    Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken. PMID:27226958

  11. pipelines cathodic protection design methodologies for impressed

    African Journals Online (AJOL)

    HOD

    oil and gas pipelines corrosion in the United State of. American alone ... or preventing external corrosion of pipeline steels and other metallic .... 2.1 Materials and Impressed Current Design. Carbon steel ..... Research Analysis, Vol. 2, pp 2277 ...

  12. Linear irreversible thermodynamics and Onsager reciprocity for information-driven engines

    Science.gov (United States)

    Yamamoto, Shumpei; Ito, Sosuke; Shiraishi, Naoto; Sagawa, Takahiro

    2016-11-01

    In the recent progress in nonequilibrium thermodynamics, information has been recognized as a kind of thermodynamic resource that can drive thermodynamic current without any direct energy injection. In this paper, we establish the framework of linear irreversible thermodynamics for a broad class of autonomous information processing. In particular, we prove that the Onsager reciprocity holds true with information: The linear response matrix is well-defined and is shown symmetric with both of the information affinity and the conventional thermodynamic affinity. As an application, we derive a universal bound for the efficiency at maximum power for information-driven engines in the linear regime. Our result reveals the fundamental role of information flow in linear irreversible thermodynamics.

  13. Estimation of stature from hand impression: a nonconventional approach.

    Science.gov (United States)

    Ahemad, Nasir; Purkait, Ruma

    2011-05-01

    Stature is used for constructing a biological profile that assists with the identification of an individual. So far, little attention has been paid to the fact that stature can be estimated from hand impressions left at scene of crime. The present study based on practical observations adopted a new methodology of measuring hand length from the depressed area between hypothenar and thenar region on the proximal surface of the palm. Stature and bilateral hand impressions were obtained from 503 men of central India. Seventeen dimensions of hand were measured on the impression. Linear regression equations derived showed hand length followed by palm length are best estimates of stature. Testing the practical utility of the suggested method on latent prints of 137 subjects, a statistically insignificant result was obtained when known and estimated stature derived from latent prints was compared. The suggested approach points to a strong possibility of its usage in crime scene investigation, albeit the fact that validation studies in real-life scenarios are performed. © 2011 American Academy of Forensic Sciences.

  14. Effect of mixing techniques on bacterial attachment and disinfection time of polyether impression material.

    Science.gov (United States)

    Guler, Umut; Budak, Yasemin; Ruh, Emrah; Ocal, Yesim; Canay, Senay; Akyon, Yakut

    2013-09-01

    The aim of this study was 2-fold. The first aim was to evaluate the effects of mixing technique (hand-mixing or auto-mixing) on bacterial attachment to polyether impression materials. The second aim was to determine whether bacterial attachment to these materials was affected by length of exposure to disinfection solutions. Polyether impression material samples (n = 144) were prepared by hand-mixing or auto-mixing. Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa were used in testing. After incubation, the bacterial colonies were counted and then disinfectant solution was applied. The effect of disinfection solution was evaluated just after the polymerization of impression material and 30 min after polymerization. Differences in adherence of bacteria to the samples prepared by hand-mixing and to those prepared by auto-mixing were assessed by Kruskal-Wallis and Mann-Whitney U-tests. For evaluating the efficiency of the disinfectant, Kruskal-Wallis multiple comparisons test was used. E. coli counts were higher in hand-mixed materials (P 2.394). The methods used for mixing polyether impression material did not affect bacterial attachment to impression surfaces. In contrast, the disinfection procedure greatly affects decontamination of the impression surface.

  15. Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues.

    Directory of Open Access Journals (Sweden)

    Ning Gan

    Full Text Available Intraoral digital impressions have been stated to meet the clinical requirements for some teeth-supported restorations, though fewer evidences were proposed for larger scanning range. The aim of this study was to compare the accuracy (trueness and precision of intraoral digital impressions for whole upper jaws, including the full dentitions and palatal soft tissues, as well as to determine the effect of different palatal vault height or arch width on accuracy of intraoral digital impressions. Thirty-two volunteers were divided into three groups according to the palatal vault height or arch width. Each volunteer received three scans with TRIOS intraoral scanner and one conventional impression of whole upper jaw. Three-dimensional (3D images digitized from conventional gypsum casts by a laboratory scanner were chose as the reference models. All datasets were imported to a specific software program for 3D analysis by "best fit alignment" and "3D compare" process. Color-coded deviation maps showed qualitative visualization of the deviations. For the digital impressions for palatal soft tissues, trueness was (130.54±33.95μm and precision was (55.26±11.21μm. For the digital impressions for upper full dentitions, trueness was (80.01±17.78μm and precision was (59.52±11.29μm. Larger deviations were found between intraoral digital impressions and conventional impressions in the areas of palatal soft tissues than that in the areas of full dentitions (p0.05, but arch width was found to have a significant effect on precision of intraoral digital impressions for full dentitions (p = 0.016. A linear correlation was found between arch width and precision of digital impressions for whole upper jaws (r = 0.326, p = 0.034 for palatal soft tissues and r = 0.485, p = 0.002 for full dentitions. It was feasible to use the intraoral scanner to obtain digital impressions for whole upper jaws. Wider dental arch contributed to lower precision of an intraoral

  16. Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues.

    Science.gov (United States)

    Gan, Ning; Xiong, Yaoyang; Jiao, Ting

    2016-01-01

    Intraoral digital impressions have been stated to meet the clinical requirements for some teeth-supported restorations, though fewer evidences were proposed for larger scanning range. The aim of this study was to compare the accuracy (trueness and precision) of intraoral digital impressions for whole upper jaws, including the full dentitions and palatal soft tissues, as well as to determine the effect of different palatal vault height or arch width on accuracy of intraoral digital impressions. Thirty-two volunteers were divided into three groups according to the palatal vault height or arch width. Each volunteer received three scans with TRIOS intraoral scanner and one conventional impression of whole upper jaw. Three-dimensional (3D) images digitized from conventional gypsum casts by a laboratory scanner were chose as the reference models. All datasets were imported to a specific software program for 3D analysis by "best fit alignment" and "3D compare" process. Color-coded deviation maps showed qualitative visualization of the deviations. For the digital impressions for palatal soft tissues, trueness was (130.54±33.95)μm and precision was (55.26±11.21)μm. For the digital impressions for upper full dentitions, trueness was (80.01±17.78)μm and precision was (59.52±11.29)μm. Larger deviations were found between intraoral digital impressions and conventional impressions in the areas of palatal soft tissues than that in the areas of full dentitions (pimpressions for palatal soft tissues was slightly better than that for full dentitions (p = 0.049). There was no significant effect of palatal vault height on accuracy of digital impressions for palatal soft tissues (p>0.05), but arch width was found to have a significant effect on precision of intraoral digital impressions for full dentitions (p = 0.016). A linear correlation was found between arch width and precision of digital impressions for whole upper jaws (r = 0.326, p = 0.034 for palatal soft tissues and r

  17. Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues

    Science.gov (United States)

    Gan, Ning; Xiong, Yaoyang; Jiao, Ting

    2016-01-01

    Intraoral digital impressions have been stated to meet the clinical requirements for some teeth-supported restorations, though fewer evidences were proposed for larger scanning range. The aim of this study was to compare the accuracy (trueness and precision) of intraoral digital impressions for whole upper jaws, including the full dentitions and palatal soft tissues, as well as to determine the effect of different palatal vault height or arch width on accuracy of intraoral digital impressions. Thirty-two volunteers were divided into three groups according to the palatal vault height or arch width. Each volunteer received three scans with TRIOS intraoral scanner and one conventional impression of whole upper jaw. Three-dimensional (3D) images digitized from conventional gypsum casts by a laboratory scanner were chose as the reference models. All datasets were imported to a specific software program for 3D analysis by "best fit alignment" and "3D compare" process. Color-coded deviation maps showed qualitative visualization of the deviations. For the digital impressions for palatal soft tissues, trueness was (130.54±33.95)μm and precision was (55.26±11.21)μm. For the digital impressions for upper full dentitions, trueness was (80.01±17.78)μm and precision was (59.52±11.29)μm. Larger deviations were found between intraoral digital impressions and conventional impressions in the areas of palatal soft tissues than that in the areas of full dentitions (pimpressions for palatal soft tissues was slightly better than that for full dentitions (p = 0.049). There was no significant effect of palatal vault height on accuracy of digital impressions for palatal soft tissues (p>0.05), but arch width was found to have a significant effect on precision of intraoral digital impressions for full dentitions (p = 0.016). A linear correlation was found between arch width and precision of digital impressions for whole upper jaws (r = 0.326, p = 0.034 for palatal soft tissues and r

  18. You are what you wear: Brand personality influences on consumer impression formation

    NARCIS (Netherlands)

    Fennis, B.M.; Pruyn, Adriaan T.H.

    2007-01-01

    The present study examines the role of brands in the process of impression formation. The article examines the hypothesis that brand personality traits may carry over and affect perceptions of the personality of the brand's owner. Based on the continuum model of impression formation the findings

  19. Evaluating the marginal fit of zirconia copings with digital impressions with an intraoral digital scanner.

    Science.gov (United States)

    An, Shinyoung; Kim, Sungtae; Choi, Hyunmin; Lee, Jae-Hoon; Moon, Hong-Seok

    2014-11-01

    Digital impression systems have been developed to overcome the disadvantages associated with conventional impression methods. The purpose of this study was to compare the marginal fit of zirconia copings designed with the use of an iTero digital scanner with those designed by the conventional impression technique. Thirty identical cast, base-metal dies from 1 maxillary central incisor prepared for a ceramic crown restoration were fabricated. For the conventional impression group (CI), base metal dies (n=10) were replicated as stone dies by means of a conventional impression technique with polyvinyl siloxane material. For the iTero with polyurethane group (iP), base metal dies (n=10) were replicated as polyurethane dies with the iTero digital impression system. For the iTero with no dies group (iNo), base metal dies (n=10) were scanned with the iTero digital impression system, but no dies were fabricated. For each group, 10 zirconia copings were fabricated based on the stone dies (CI group), polyurethane dies (iP group), or stereolithography files (iNo group). The marginal gap of each specimen was measured with a light microscope at ×50 magnification. One-way analysis of variance and the Tukey honestly significant difference test were used for statistical analysis (α=.05). Statistically significant differences were found between the CI group and iP group (Pdigital impression method than in the group that used the conventional impression method. However, the marginal discrepancies of all of the groups were clinically acceptable. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Teaching: First Impressions First, or Choosing Atmosphere over Method and Management

    Science.gov (United States)

    Levy, Aaron

    2004-01-01

    As a writer who teaches and a teacher who writes, this author offers creative ways of producing a positive first impression on the first day of school. The key is finding a way to surprise one's students and creating first impressions that somehow introduces the tone a teacher wants his or her class to have. The author has learned that if he can…

  1. Mathematical models and equilibrium in irreversible microeconomics

    Directory of Open Access Journals (Sweden)

    Anatoly M. Tsirlin

    2010-07-01

    Full Text Available A set of equilibrium states in a system consisting of economic agents, economic reservoirs, and firms is considered. Methods of irreversible microeconomics are used. We show that direct sale/purchase leads to an equilibrium state which depends upon the coefficients of supply/demand functions. To reach the unique equilibrium state it is necessary to add either monetary exchange or an intermediate firm.

  2. Effect of fluoride addition on the properties of dental alginate impression materials.

    Science.gov (United States)

    Lee, Yong-Keun; Lim, Bum-Soon; Kim, Cheol-We

    2004-03-01

    Fluoride-containing dental alginate impression materials can exert a considerable reduction in enamel solubility. The objective was to evaluate the effects of fluoride addition in the alginate impression materials on the properties and subsequent release of fluoride. Four experimental alginate impression materials were studied. Materials were mixed with distilled water (control) or 100-ppm fluoride solution. One or two percent NaF, or 1% SnF2 was added to the materials, which were mixed with distilled water. Fluoride release, flexibility, recovery from deformation, setting time, compressive strength and elastic modulus were determined in accordance with the ISO 1563 and ANSI/ADA Spec. 18. Fluoride release increased after addition of fluoride, and the released amount was 0.762-14.761 ppm. Addition of NaF or SnF2 resulted in higher fluoride release than the control group (p alginate impression material may result in effective release of fluoride without deteriorating the properties of material itself.

  3. Impression management and self-presentation dissimulation in Portuguese chairman's statements

    OpenAIRE

    Oliveira, J.; Azevedo, G.; Borges, F.

    2016-01-01

    WOS:000381979800008 (Nº de Acesso Web of Science) Drawn on social psychology theory of impression management, the present study tries to assess the way Portuguese managers build their narratives in Chairman’s Statement to manage stakeholders’ perceptions on corporate image, in a period of time of scarce resources. The paper’s theoretical framework draws on elements of social psychology theory of impression management developed by Leary and Kowalski (1990). Through the use of the two-compon...

  4. Expression and Bodily Faith in Natalie Heller’s First Impressions

    Directory of Open Access Journals (Sweden)

    Adam Loughnane

    2016-07-01

    Full Text Available In this essay I place choreographer Natalie Heller in dialogue with Merleau-Ponty on issues of motor-perception, expression and bodily faith. I analyze her new work First Impressions to demonstrate how she responds to a similar impulse that drove Merleau-Ponty’s phenomenology, particularly in his last writing, The Visible and the Invisible. Both Heller and Merleau-Ponty seek to go beyond the representational understanding of motion and perception in order to articulate and experiment with a type of expression, which is beyond the distinctions between motion and motionlessness, activity and passivity, visibility and invisibility. While Merleau-Ponty writes about this form of expression, Heller’s performers show that beyond these binaries is a form of expression that is ambiguously situated between impressing and being impressed upon, and that to engage the world or the city as such, requires a motor-perceptual form of faith.

  5. Examination of the Position Accuracy of Implant Abutments Reproduced by Intra-Oral Optical Impression

    Science.gov (United States)

    Odaira, Chikayuki; Kobayashi, Takuya; Kondo, Hisatomo

    2016-01-01

    An impression technique called optical impression using intraoral scanner has attracted attention in digital dentistry. This study aimed to evaluate the accuracy of the optical impression, comparing a virtual model reproduced by an intraoral scanner to a working cast made by conventional silicone impression technique. Two implants were placed on a master model. Working casts made of plaster were fabricated from the master model by silicone impression. The distance between the ball abutments and the angulation between the healing abutments of 5 mm and 7 mm height at master model were measured using Computer Numerical Control Coordinate Measuring Machine (CNCCMM) as control. Working casts were then measured using CNCCMM, and virtual models via stereo lithography data of master model were measured by a three-dimensional analyzing software. The distance between ball abutments of the master model was 9634.9 ± 1.2 μm. The mean values of trueness of the Lava COS and working casts were 64.5 μm and 22.5 μm, respectively, greater than that of control. The mean of precision values of the Lava COS and working casts were 15.6 μm and 13.5 μm, respectively. In the case of a 5-mm-height healing abutment, mean angulation error of the Lava COS was greater than that of the working cast, resulting in significant differences in trueness and precision. However, in the case of a 7-mm-height abutment, mean angulation errors of the Lava COS and the working cast were not significantly different in trueness and precision. Therefore, distance errors of the optical impression were slightly greater than those of conventional impression. Moreover, the trueness and precision of angulation error could be improved in the optical impression using longer healing abutments. In the near future, the development of information technology could enable improvement in the accuracy of the optical impression with intraoral scanners. PMID:27706225

  6. Linear dimensional stability of elastomeric impression materials over time.

    Science.gov (United States)

    Garrofé, Analía B; Ferrari, Beatriz A; Picca, Mariana; Kaplan, Andrea E

    2011-01-01

    The purpose of this study was to evaluate the linear dimensional stability of different elastomeric impression materials over time. A metal mold was designed with its custom trays, which were made of thermoplastic sheets (Sabilex sheets 0.125 mm thick). Three impressions were taken of it with each of the following: the polyvinylsiloxane Examix-GC-(AdEx), Aquasil-Dentsply-(AdAq) and Panasil-Kettenbach-(AdPa), and the polydimethylsiloxane Densell-Dental Medrano-(CoDe), Speedex-Coltene-(CoSp) and Lastic-Kettenbach-(CoLa). All impressions were taken with putty and light-body materials using a one-step technique. Standardized digital photographs were taken at different time intervals (0, 15, 30, 60, 120 minutes; 24 hours; 7 and 14 days), using an "ad-hoc" device, and analyzed using software (Image Tool) by measuring the distance between lines previously made at the top of the mold. The results were analyzed by ANOVA for repeated measures. The initial and final values for mean and SD were: AdEx: 1.32 (0.01) and 1.31 (0.00); AdAq: 1.32 (0.00) and 1.32 (0.00), AdPa: 1.327 (0.006) and 1.31 (0.00); CoDe: 1.32 (0.00) and 1.32 (0.01); CoSp: 1.327 (0.006) and 1.31 (0.00), CoLa: 1.327 (0.006) and 1.303 (0.006). Statistical evaluation showed that both material and time have significant effects. Under the conditions in this study we conclude that time would significantly affect the lineal dimensional stability of elastomeric impression materials.

  7. Anistropically varying conductivity in irreversible electroporation simulations.

    Science.gov (United States)

    Labarbera, Nicholas; Drapaca, Corina

    2017-11-01

    One recent area of cancer research is irreversible electroporation (IRE). Irreversible electroporation is a minimally invasive procedure where needle electrodes are inserted into the body to ablate tumor cells with electricity. The aim of this paper is to propose a mathematical model that incorporates a tissue's conductivity increasing more in the direction of the electrical field as this has been shown to occur in experiments. It was necessary to mathematically derive a valid form of the conductivity tensor such that it is dependent on the electrical field direction and can be easily implemented into numerical software. The derivation of a conductivity tensor that can take arbitrary functions for the conductivity in the directions tangent and normal to the electrical field is the main contribution of this paper. Numerical simulations were performed for isotropic-varying and anisotropic-varying conductivities to evaluate the importance of including the electrical field's direction in the formulation for conductivity. By starting from previously published experimental results, this paper derived a general formulation for an anistropic-varying tensor for implementation into irreversible electroporation modeling software. The anistropic-varying tensor formulation allows the conductivity to take into consideration both electrical field direction and magnitude, as opposed to previous published works that only took into account electrical field magnitude. The anisotropic formulation predicts roughly a five percent decrease in ablation size for the monopolar simulation and approximately a ten percent decrease in ablation size for the bipolar simulations. This is a positive result as previously reported results found the isotropic formulation to overpredict ablation size for both monopolar and bipolar simulations. Furthermore, it was also reported that the isotropic formulation overpredicts the ablation size more for the bipolar case than the monopolar case. Thus, our

  8. Ecological optimization for an irreversible magnetic Ericsson refrigeration cycle

    International Nuclear Information System (INIS)

    Wang Hao; Wu Guo-Xing

    2013-01-01

    An irreversible Ericsson refrigeration cycle model is established, in which multi-irreversibilities such as finite-rate heat transfer, regenerative loss, heat leakage, and the efficiency of the regenerator are taken into account. Expressions for several important performance parameters, such as the cooling rate, coefficient of performance (COP), power input, exergy output rate, entropy generation rate, and ecological function are derived. The influences of the heat leakage and the time of the regenerative processes on the ecological performance of the refrigerator are analyzed. The optimal regions of the ecological function, cooling rate, and COP are determined and evaluated. Furthermore, some important parameter relations of the refrigerator are revealed and discussed in detail. The results obtained here have general significance and will be helpful in gaining a deep understanding of the magnetic Ericsson refrigeration cycle. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  9. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

    OpenAIRE

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin; Hwang, Hyeon-Shik

    2016-01-01

    Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions wer...

  10. Detailed Modeling and Irreversible Transfer Process Analysis of a Multi-Element Thermoelectric Generator System

    Science.gov (United States)

    Xiao, Heng; Gou, Xiaolong; Yang, Suwen

    2011-05-01

    Thermoelectric (TE) power generation technology, due to its several advantages, is becoming a noteworthy research direction. Many researchers conduct their performance analysis and optimization of TE devices and related applications based on the generalized thermoelectric energy balance equations. These generalized TE equations involve the internal irreversibility of Joule heating inside the thermoelectric device and heat leakage through the thermoelectric couple leg. However, it is assumed that the thermoelectric generator (TEG) is thermally isolated from the surroundings except for the heat flows at the cold and hot junctions. Since the thermoelectric generator is a multi-element device in practice, being composed of many fundamental TE couple legs, the effect of heat transfer between the TE couple leg and the ambient environment is not negligible. In this paper, based on basic theories of thermoelectric power generation and thermal science, detailed modeling of a thermoelectric generator taking account of the phenomenon of energy loss from the TE couple leg is reported. The revised generalized thermoelectric energy balance equations considering the effect of heat transfer between the TE couple leg and the ambient environment have been derived. Furthermore, characteristics of a multi-element thermoelectric generator with irreversibility have been investigated on the basis of the new derived TE equations. In the present investigation, second-law-based thermodynamic analysis (exergy analysis) has been applied to the irreversible heat transfer process in particular. It is found that the existence of the irreversible heat convection process causes a large loss of heat exergy in the TEG system, and using thermoelectric generators for low-grade waste heat recovery has promising potential. The results of irreversibility analysis, especially irreversible effects on generator system performance, based on the system model established in detail have guiding significance for

  11. Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions.

    Science.gov (United States)

    Svanborg, Per; Skjerven, Henrik; Carlsson, Pablo; Eliasson, Alf; Karlsson, Stig; Ortorp, Anders

    2014-01-01

    Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth supported fixed dental prostheses (FDPs) fabricated from digital and conventional impressions. Methods. Ten FDPs were produced from digital impressions using the iTero system and 10 FDPs were produced using vinyl polysiloxane (VPS) impression material. A triple-scan protocol and CAD software were used for measuring and calculating discrepancies of the FDPs at 3 standard areas: mean internal discrepancy, absolute marginal gap, and cervical area discrepancy. The Mann-Whitney U test was used for analyzing the results. Results. For conventional and digital impressions, respectively, FDPs had an absolute marginal gap of 147  μ m and 142  μ m, cervical area discrepancy of 69  μ m and 44  μ m, and mean internal discrepancy of 117  μ m and 93  μ m. The differences were statistically significant in the cervical and internal areas (P digital impression technique is more exact and can generate 3-unit FDPs with a significantly closer fit compared to the VPS technique.

  12. Surface roughness of polyvinyl siloxane impression materials following chemical disinfection, autoclave and microwave sterilization.

    Science.gov (United States)

    Al Kheraif, Abdulaziz Abdullah

    2013-05-01

    Autoclave sterilization and microwave sterilization has been suggested as the effective methods for the disinfection of elastomeric impressions, but subjecting elastomeric impressions to extreme temperature may have adverse effects on critical properties of the elastomers. To evaluate the effect of chemical disinfection as well as autoclave and microwave sterilization on the surface roughness of elastomeric impression materials. The surface roughness of five commercially available polyvinyl siloxane impression materials (Coltene President, Affinis Perfect impression, Aquasil, 3M ESPE Express and GC Exafast) were evaluated after subjecting them to chemical disinfection, autoclaving and microwave sterilization using a Talysurf Intra 50 instrument. Twenty specimens from each material were fabricated and divided into four equal groups, three experimental and one control (n=25). The differences in the mean surface roughness between the treatment groups were recorded and statistically analyzed. No statistically significant increase in the surface roughness was observed when the specimens were subjected to chemical disinfection and autoclave sterilization, increase in roughness and discoloration was observed in all the materials when specimens were subjected to microwave sterilization. Chemical disinfection did not have a significant effect but, since it is less effective, autoclave sterilization can be considered effective and autoclaving did not show any specimen discoloration as in microwave sterilization. Microwave sterilization may be considered when impressions are used to make diagnostic casts. A significant increase in surface roughness may produce rougher casts, resulting in rougher tissue surfaces for denture and cast restorations. Autoclave sterilization of vinyl polysiloxane elastomeric impressions for 5 minutes at 134°C at 20 psi may be considered an effective method over chemical disinfection and microwave sterilization, because chemical disinfection does

  13. Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring.

    Directory of Open Access Journals (Sweden)

    Stephania Caroline Rodolfo Silva

    Full Text Available This study evaluated the accuracy of gypsum casts after different impression techniques and double pouring. Ten patients were selected and for each one it was obtained 5 partial putty/wash impressions with vinyl polysiloxane (VPS material from teeth #13 to #16 with partial metal stock trays. The following techniques were performed: (1 one-step; two-step relief with: (2 PVC film; (3 slow-speed tungsten carbide bur and scalpel blade, (4 small movements of the tray and (5 without relief-negative control. The impressions were disinfected with 0.5% sodium hypochlorite for 10 minutes and stored during 110 and 230 minutes for the first and second pouring, respectively, with type IV gypsum. Three intra-oral lateral photographs of each patient were taken using a tripod and a customized radiographic positioner. The images were imported into ImageJ software and the total area of the buccal surface from teeth #13 to #16 was measured. A 4.0% coefficient of variance was criterion for using these measurements as Baseline values. The casts were photographed and analyzed using the same standardization for the clinical images. The area (mm2 obtained from the difference between the measurements of each gypsum cast and the Baseline value of the respective patient were calculated and analyzed by repeated-measures two way-ANOVA and Mauchly's Sphericity test (α = 0.05. No significant effect was observed for Impression technique (P = 0.23, Second pouring (P = 0.99 and their interaction (P = 0.25. The impression techniques and double pouring did not influence the accuracy of the gypsum casts.

  14. Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold

    International Nuclear Information System (INIS)

    Lee, Kyoung Ho; Kim, Young Hoon; Kim, Bo Hyoung; Kim, Kil Joong; Kim, Tae Jung; Kim, Hyuk Jung; Hahn, Seokyung

    2007-01-01

    To estimate the visually lossless threshold for Joint Photographic Experts Group (JPEG) 2000 compression of contrast-enhanced abdominal computed tomography (CT) images, 100 images were compressed to four different levels: a reversible (as negative control) and irreversible 5:1, 10:1, and 15:1. By alternately displaying the original and the compressed image on the same monitor, six radiologists independently determined if the compressed image was distinguishable from the original image. For each reader, we compared the proportion of the compressed images being rated distinguishable from the original images between the reversible compression and each of the three irreversible compressions using the exact test for paired proportions. For each reader, the proportion was not significantly different between the reversible (0-1%, 0/100 to 1/100) and irreversible 5:1 compression (0-3%). However, the proportion significantly increased with the irreversible 10:1 (95-99%) and 15:1 compressions (100%) versus reversible compression in all readers (P < 0.001); 100 and 95% of the 5:1 compressed images were rated indistinguishable from the original images by at least five of the six readers and all readers, respectively. Irreversibly 5:1 compressed abdominal CT images are visually lossless and, therefore, potentially acceptable for primary interpretation. (orig.)

  15. Accuracy of various impression materials and methods for two implant systems: An effect size study.

    Science.gov (United States)

    Schmidt, Alexander; Häussling, Teresa; Rehmann, Peter; Schaaf, Heidrun; Wöstmann, Bernd

    2018-04-01

    An accurate impression is required for implant treatment. The aim of this in-vitro study was to determine the effect size of the impression material/method, implant system and implant angulation on impression transfer precision. An upper jaw model with three BEGO and three Straumann implants (angulations 0°, 15°, 20°) in the left and right maxilla was used as a reference model. One polyether (Impregum Penta) and two polyvinyl siloxanes (Flexitime Monophase/Aquasil Ultra Monophase) were examined with two impression techniques (open and closed tray). A total of 60 impressions were made. A coordinate measurement machine was used to measure the target variables for 3D-shift, implant axis inclination and implant axis rotation. All the data were subjected to a four-way ANOVA. The effect size (partial eta-squared [η 2 P ]) was reported. The impression material had a significant influence on the 3D shift and the implant axis inclination deviation (p-values=.000), and both factors had very large effect sizes (3D-shift [η 2 P ]=.599; implant axis inclination [η 2 P ]=.298). Impressions made with polyvinyl siloxane exhibited the highest transfer precision. When the angulation of the implants was larger, more deviations occurred for the implant axis rotational deviation. The implant systems and impression methods showed partially significant variations (p-values=.001-.639) but only very small effect sizes (η 2 P =.001-.031). The impression material had the greatest effect size on accuracy in terms of the 3D shift and the implant axis inclination. For multiunit restorations with disparallel implants, polyvinyl siloxane materials should be considered. In addition, the effect size of a multivariate investigation should be reported. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  16. Effect of digital impressions and production protocols on the adaptation of zirconia copings.

    Science.gov (United States)

    Kocaağaoğlu, Hasan; Kılınç, Halil Ibrahim; Albayrak, Haydar

    2017-01-01

    Proper marginal, axial, and occlusal adaptation of dental restorations is essential for their long-term success. Production protocols including digital impression systems have been developed, but little information is available on the adaptation of zirconia restorations produced via them. The purpose of this in vitro study was to compare the effects of digital impression protocols on the marginal, axial, and occlusal adaptation of zirconia copings. Thirty extracted human maxillary premolar teeth without caries or defects were used. The teeth were prepared for zirconia crowns and randomly divided into 3 groups. Zirconia copings were designed at a thickness of 0.5 mm with 30 μm of simulated die spacer starting 1 mm from the margin of preparations. They were produced using computer-aided design-computer-aided manufacture (CAD-CAM) protocol with a conventional impression (group Cn) and 2 different production protocols with digital impressions (group C) and group Tr. The marginal, axial, and occlusal discrepancies of these copings were measured using the silicone replica technique with stereomicroscopy at ×50 magnification, and the data were analyzed with 1-way ANOVAs (α=.05). The mean marginal discrepancy values were 85.6 μm for group Cn, 58.7 μm for group C, and 47.7 μm for the Tr group. Significant differences were found among the production protocols in marginal, axial, and occlusal discrepancies (Pdigital impressions had significantly fewer marginal discrepancies than those of group Cn (P.05), and group Tr revealed the lowest axial discrepancy (P.05). The copings produced with the aid of digital impression systems exhibited better marginal and occlusal adaptation than those of the copings produced with the aid of conventional impression. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Disinfectant Efficacy of 0.525% Sodium Hypochlorite and Epimax on Alginate Impression Material.

    Science.gov (United States)

    Choudhury, Gopal Krishna; Chitumalla, Rajkiran; Manual, Litto; Rajalbandi, Santosh Kumar; Chauhan, Mahinder Singh; Talukdar, Pratim

    2018-01-01

    Species of Streptococcus, Escherichia coli, Staphylococcus, Actinomyces, Pseudomonas, Klebsiella, and Candida are commonly seen in the oral cavity. Impression materials are commonly contaminated with microorganisms. The present study was conducted to assess the disinfection efficacy of Epimax and 0.525% sodium hypochlorite on alginate impression over a period of 10 minutes. This study was conducted in the Department of Prosthodontics in the year 2015. An alginate impression material was prepared. For each bacteria species, 15 samples were used. Out of 15 samples, 3 were used by 0.525% sodium hypochlorite for disinfection for 5 minutes and 3 others for 10 minutes. Similarly, 3 samples were used by Epimax for 5 minutes and other 3 for 10 minutes. Three samples were used as controls. Each sample was polluted with Candida albicans, Pseudomonas aeruginosa, and Staphylococcus aureus strains. There was no statistical difference in P. aeruginosa and C. albicans after 5 minutes, whereas S. aureus showed significant difference (p alginate impression material against C. albicans, P. aeruginosa, and S. aureus strains. However, Epimax was found to be more effective against S. aureus as compared with 0.525% sodium hypochlorite. Efficacy of disinfection of sodium hypo-chlorite and Epimax on alginate impression.

  18. Prostaglandin E2 to diagnose between reversible and irreversible pulpitis.

    Science.gov (United States)

    Petrini, M; Ferrante, M; Ciavarelli, L; Brunetti, L; Vacca, M; Spoto, G

    2012-01-01

    The aim of this work is to verify a correlation between the grade of inflammation and the concentration of PGE2 in human dental pulp. A total of 25 human dental pulps were examined by histological analysis and radioimmunologic dosage of PGE2. The pulps used in this experiment were from healthy and symptomatic teeth; the first ones were collected from teeth destined to be extracted for orthodontic reasons. An increase was observed of PGE2 in reversible pulpitis compared with healthy pulps and with the irreversible pulpitis and the clear decrease of these when NSAIDs are taken. This study demonstrates that PGE2 level is correlated to histological analysis thus allowing to distinguish symptomatic teeth in reversible and irreversible pulpitis.

  19. Resistance to disinfection of a polymicrobial association contaminating the surface of elastomeric dental impressions.

    Science.gov (United States)

    Giammanco, Giovanni M; Melilli, Dario; Rallo, Antonio; Pecorella, Sonia; Mammina, Caterina; Pizzo, Giuseppe

    2009-04-01

    The aim of this study was to evaluate the ability to resist disinfection of a polymicrobial association contaminating the surface of dental impressions obtained with two different elastomers: a polyether (Impregum) and an addition-polymerized silicone (Elite). Impressions were contaminated with a mixture of three biofilm-forming microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans) and disinfected immediately after contamination, or after microbial layers were allowed to develop during a six-hour storage. Two commercial disinfectants were tested: MD 520 containing 0.5% glutaraldehyde and Sterigum Powder without glutaraldehyde. Residual contamination was recovered by mechanical rinsing immediately after disinfection and after a six-hour storage of disinfected impressions, and assessed by colony counting. Both disinfectants tested were shown to be effective in reducing the microbial presence on the impression materials, achieving at least a 102 reduction of microbial counts compared to water rinsing. However, Sterigum was generally less effective on the Elite elastomer and could not grant disinfection on six-hour aged P. aeruginosa and C. albicans microbial layers. The results of this study suggest that the materials used for the impressions influence the efficacy of disinfection. Disinfectants should be tested according to conditions encountered in everyday clinical practice and the need for immediate disinfection of impressions should be clearly indicated by manufacturers.

  20. Dental impressions using 3D digital scanners: virtual becomes reality.

    Science.gov (United States)

    Birnbaum, Nathan S; Aaronson, Heidi B

    2008-10-01

    The technologies that have made the use of three-dimensional (3D) digital scanners an integral part of many industries for decades have been improved and refined for application to dentistry. Since the introduction of the first dental impressioning digital scanner in the 1980s, development engineers at a number of companies have enhanced the technologies and created in-office scanners that are increasingly user-friendly and able to produce precisely fitting dental restorations. These systems are capable of capturing 3D virtual images of tooth preparations, from which restorations may be fabricated directly (ie, CAD/CAM systems) or fabricated indirectly (ie, dedicated impression scanning systems for the creation of accurate master models). The use of these products is increasing rapidly around the world and presents a paradigm shift in the way in which dental impressions are made. Several of the leading 3D dental digital scanning systems are presented and discussed in this article.