  1. Fusion Materials Irradiation Test Facility: experimental capabilities and test matrix

    International Nuclear Information System (INIS)

    Opperman, E.K.

    1982-01-01

    This report describes the experimental capabilities of the Fusion Materials Irradiation Test Facility (FMIT) and reference material specimen test matrices. The description of the experimental capabilities and the test matrices has been updated to match the current single test cell facility ad assessed experimenter needs. Sufficient detail has been provided so that the user can plan irradiation experiments and conceptual hardware. The types of experiments, irradiation environment and support services that will be available in FMIT are discussed

  2. Fusion Materials Irradiation Test Facility: a facility for fusion-materials qualification

    International Nuclear Information System (INIS)

    Trego, A.L.; Hagan, J.W.; Opperman, E.K.; Burke, R.J.

    1983-01-01

    The Fusion Materials Irradiation Test Facility will provide a unique testing environment for irradiation of structural and special purpose materials in support of fusion power systems. The neutron source will be produced by a deuteron-lithium stripping reaction to generate high energy neutrons to ensure damage similar to that of a deuterium-tritium neutron spectrum. The facility design is now ready for the start of construction and much of the supporting lithium system research has been completed. Major testing of key low energy end components of the accelerator is about to commence. The facility, its testing role, and the status and major aspects of its design and supporting system development are described

  3. The Advanced Test Reactor Irradiation Facilities and Capabilities

    International Nuclear Information System (INIS)

    S. Blaine Grover; Raymond V. Furstenau

    2007-01-01

    The Advanced Test Reactor (ATR) is one of the world's premiere test reactors for performing long term, high flux, and/or large volume irradiation test programs. The ATR is a very versatile facility with a wide variety of experimental test capabilities for providing the environment needed in an irradiation experiment. These different capabilities include passive sealed capsule experiments, instrumented and/or temperature-controlled experiments, and pressurized water loop experiment facilities. The ATR has enhanced capabilities in experiment monitoring and control systems for instrumented and/or temperature controlled experiments. The control systems utilize feedback from thermocouples in the experiment to provide a custom blended flowing inert gas mixture to control the temperature in the experiments. Monitoring systems have also been utilized on the exhaust gas lines from the experiment to monitor different parameters, such as fission gases for fuel experiments, during irradiation. ATR's unique control system provides axial flux profiles in the experiments, unperturbed by axially positioned control components, throughout each reactor operating cycle and over the duration of test programs requiring many years of irradiation. The ATR irradiation positions vary in diameter from 1.6 cm (0.625 inches) to 12.7 cm (5.0 inches) over an active core length of 122 cm (48.0 inches). Thermal and fast neutron fluxes can be adjusted radially across the core depending on the needs of individual test programs. This paper will discuss the different irradiation capabilities available and the cost/benefit issues related to each capability. Examples of different experiments will also be discussed to demonstrate the use of the capabilities and facilities at ATR for performing irradiation experiments

  4. Fusion Materials Irradiation Test Facility

    International Nuclear Information System (INIS)

    Kemp, E.L.; Trego, A.L.

    1979-01-01

    A Fusion Materials Irradiation Test Facility is being designed to be constructed at Hanford, Washington, The system is designed to produce about 10 15 n/cm-s in a volume of approx. 10 cc and 10 14 n/cm-s in a volume of 500 cc. The lithium and target systems are being developed and designed by HEDL while the 35-MeV, 100-mA cw accelerator is being designed by LASL. The accelerator components will be fabricated by US industry. The total estimated cost of the FMIT is $105 million. The facility is scheduled to begin operation in September 1984

  5. New facilities in Japan materials testing reactor for irradiation test of fusion reactor components

    International Nuclear Information System (INIS)

    Kawamura, H.; Sagawa, H.; Ishitsuka, E.; Sakamoto, N.; Niiho, T.

    1996-01-01

    The testing and evaluation of fusion reactor components, i.e. blanket, plasma facing components (divertor, etc.) and vacuum vessel with neutron irradiation is required for the design of fusion reactor components. Therefore, four new test facilities were developed in the Japan Materials Testing Reactor: an in-pile functional testing facility, a neutron multiplication test facility, an electron beam facility, and a re-weldability facility. The paper describes these facilities

  6. Fusion materials irradiation test facility: description and status

    International Nuclear Information System (INIS)

    Trego, A.L.; Parker, E.F.; Hagan, J.W.

    1982-01-01

    The Fusion Materials Irradiation Test (FMIT) Facility will generate a high-flux, high-energy neutron source that will provide a fusion-like radiation environment for fusion reactor materials development. The neutrons will be produced in a nuclear stripping reaction by impinging a 35 MeV beam of deuterons from an Alvarez-type linear accelerator on a flowing lithium target. The target will be located in a test cell which will provide an irradiation volume of over 750l within which 10 cm 3 will have an average neutron flux of greater than 1.4 x 10 15 n/cm 2 -s and 500 cm 3 an average flux of greater than 2.2 by 10 14 n/cm 2- s with an expected availability factor greater than 65%. The projected fluence within the 10 cm 3 high flux region of FMIT will effect damage upon the materials test specimens to 30 dpa (displacements per atom) for each 90 day irradiation period. This irradiation flux volume will be at least 500 times larger than that of any other facility with comparable neutron energy and will fully meet the fusion materials damage research objective of 100 dpa within three years for the first round of tests

  7. Development of post-irradiation test facility for domestic production of 99Mo

    International Nuclear Information System (INIS)

    Taguchi, Taketoshi; Yonekawa, Minoru; Kato, Yoshiaki; Kurosawa, Makoto; Nishikata, Kaori; Ishida, Takuya; Kawamata, Kazuo

    2013-01-01

    JMTR focus on the activation method. By carrying out the preliminary tests using irradiation facilities existing, and verification tests using the irradiation facility that has developed in the cutting-edge research and development strategic strengthening business, as irradiation tests towards the production of 99 Mo, we have been conducting research and development that can contribute to supply about 25% for 99 Mo demand in Japan and the stable supply of radiopharmaceutical. This report describes a summary of the status of the preliminary tests for the production of 99 Mo: Maintenance of test equipment in the facility in JMTR hot laboratory in preparation for research and development for the production of 99 Mo in JMTR and using MoO 3 pellet irradiated at Kyoto University Research Reactor Institute (KUR). (author)

  8. Remote-handling demonstration tests for the Fusion Materials Irradiation Test (FMIT) Facility

    International Nuclear Information System (INIS)

    Shen, E.J.; Hussey, M.W.; Kelly, V.P.; Yount, J.A.

    1982-01-01

    The mission of the Fusion Materials Irradiation Test (FMIT) Facility is to create a fusion-like environment for fusion materials development. Crucial to the success of FMIT is the development and testing of remote handling systems required to handle materials specimens and maintenance of the facility. The use of full scale mock-ups for demonstration tests provides the means for proving these systems

  9. NRI experimental facility for the testing of irradiation assisted stress corrosion cracking

    International Nuclear Information System (INIS)

    Ruscak, M.; Chvatal, P.; Zamboch, M.

    1998-01-01

    IASCC influencing reactor internals of both BWR and PWR reactors is a complex phenomenon covering influences of material structure, neutron fluence, neutron flux, chemistry of environment, gamma radiation and mechanical stress. To evaluate such degradation, tests should be performed under conditions similar to those in real structure. Nuclear Research Institute has built several experimental facilities in order to be able to test IASCC degradation of materials. Basically, reactor water loops, both PWR and BWR, could be used to model environmental conditions including gamma and neutron irradiation. Pre-irradiation can be done in irradiation channels under well controlled temperature conditions. During the experiment, in-pile conditions can be compared with those out of pile. It enables to clarify pure influence of irradiation. For testing of irradiated specimens, hot cell facility has been developed for slow strain rate tests. The paper will show all above mentioned facilities as well as some of the results observed with them. (author)

  10. IFMIF [International Fusion Materials Irradiation Facility], an accelerator-based neutron source for fusion components irradiation testing: Materials testing capabilities

    International Nuclear Information System (INIS)

    Mann, F.M.

    1988-08-01

    The International Fusion Materials Irradiation Facility (IFMIF) is proposed as an advanced accelerator-based neutron source for high-flux irradiation testing of large-sized fusion reactor components. The facility would require only small extensions to existing accelerator and target technology originally developed for the Fusion Materials Irradiation Test (FMIT) facility. At the extended facility, neutrons would be produced by a 0.1-A beam of 35-MeV deuterons incident upon a liquid lithium target. The volume available for high-flux (>10/sup 15/ n/cm/sup 2/-s) testing in IFMITF would be over a liter, a factor of about three larger than in the FMIT facility. This is because the effective beam current of 35-MeV deuterons on target can be increased by a factor of ten to 1A or more. Such an increase can be accomplished by funneling beams of deuterium ions from the radio-frequency quadruple into a linear accelerator and by taking advantage of recent developments in accelerator technology. Multiple beams and large total current allow great variety in available testing. For example, multiple simultaneous experiments, and great flexibility in tailoring spatial distributions of flux and spectra can be achieved. 5 refs., 2 figs., 1 tab

  11. Transfer of test samples and wastes between post-irradiation test facilities (FMF, AGF, MMF)

    International Nuclear Information System (INIS)

    Ishida, Yasukazu; Suzuki, Kazuhisa; Ebihara, Hikoe; Matsushima, Yasuyoshi; Kashiwabara, Hidechiyo

    1975-02-01

    Wide review is given on the problems associated with the transfer of test samples and wastes between post-irradiation test facilities, FMF (Fuel Monitoring Facility), AGF (Alpha Gamma Facility), and MMF (Material Monitoring Facility) at the Oarai Engineering Center, PNC. The test facilities are connected with the JOYO plant, an experimental fast reactor being constructed at Oarai. As introductory remarks, some special features of transferring irradiated materials are described. In the second part, problems on the management of nuclear materials and radio isotopes are described item by item. In the third part, the specific materials that are envisaged to be transported between JOYO and the test facilities are listed together with their geometrical shapes, dimensions, etc. In the fourth part, various routes and methods of transportation are explained with many block charts and figures. Brief explanation with lists and drawings is also given to transportation casks and vessels. Finally, some future problems are discussed, such as the prevention of diffusive contamination, ease of decontamination, and the identification of test samples. (Aoki, K.)

  12. FMIT - the fusion materials irradiation test facility

    International Nuclear Information System (INIS)

    Liska, D.J.

    1980-01-01

    A joint effort by the Hanford Engineering Development Laboratory (HEDL) and Los Alamos Scientific Laboratory (LASL) has produced a preliminary design for a Fusion Materials Irradiation Test Facility (FMIT) that uses a high-power linear accelerator to fire a deuteron beam into a high-speed jet of molten lithium. The result is a continuous energy spectrum of neutrons with a 14-MeV average energy which can irradiate material samples to projected end-of-life levels in about 3 years, with a total accumulated fluence of 10 21 to 10 22 n/cm 2

  13. In-cell facility for performing mechanical-property tests on irradiated cladding

    International Nuclear Information System (INIS)

    Yaggee, F.L.; Haglund, R.C.; Mattas, R.F.

    1978-11-01

    A new facility was developed for testing cladding sections of LWR fuel rods. This facility and the accompanying test procedures have improved the level of in-cell mechanical-testing capabilities, making them comparable to existing capabilities for unirradiated cladding. The new facility is currently being used to study the susceptibility of irradiated Zircaloy cladding from LWR fuel rods to iodine stress-corrosion cracking. Preliminary testing results indicate a systematic effect of temperature, stress and irradiation on the susceptibility of annealed and stress-relieved Zircaloy-2. Experimental data obtained to date are being used to develop a stress-corrosion cracking model for LWR fuel rod failure. SEM examination of the undisturbed fracture surface of specimens that failed by pinhole leakage provides useful information on crack propagation and morphology

  14. Irradiation facilities in JRR-3M

    International Nuclear Information System (INIS)

    Ohtomo, Akitoshi; Sigemoto, Masamitsu; Takahashi, Hidetake

    1992-01-01

    Irradiation facilities have been installed in the upgraded JRR-3 (JRR-3M) in Japan Atomic Energy Research Institute (JAERI). There are hydraulic rabbit facilities (HR), pneumatic rabbit facilities (PN), neutron activation analysis facility (PN3), uniform irradiation facility (SI), rotating irradiation facility and capsule irradiation facilities to carry out the neutron irradiation in the JRR-3M. These facilities are operated using a process control computer system to centerize the process information. Some of the characteristics for the facilities were satisfactorily measured at the same time of reactor performance test in 1990. During reactor operation, some of the tests are continued to confirm the basic characteristics on facilities, for example, PN3 was confirmed to have enough performance for activation analysis. Measurement of neutron flux at all irradiation positions has been carried out for the equilibrium core. (author)

  15. Improvement of irradiation facilities performance in JMTR

    International Nuclear Information System (INIS)

    Kanno, Masaru; Sakurai, Susumu; Honma, Kenzo; Sagawa, Hisashi; Nakazaki, Chousaburo

    1999-01-01

    Various kinds of irradiation facilities are installed in the JMTR for the purpose of irradiation tests on fuels and materials and of producing radioisotopes. The irradiation facilities have been improved so far at every opportunity of new irradiation requirements and of renewing them which reached the design lifetime. Of these irradiation facilities, improvements of the power ramping test facility (BOCA/OSF-1 facility) and the hydraulic rabbit No.2 (HR-2 facility) are described here. (author)

  16. Present status of ESNIT (energy selective neutron irradiation test facility) program

    International Nuclear Information System (INIS)

    Noda, K.; Ohno, H.; Sugimoto, M.; Kato, Y.; Matsuo, H.; Watanabe, K.; Kikuchi, T.; Sawai, T.; Usui, T.; Oyama, Y.; Kondo, T.

    1994-01-01

    The present status of technical studies of a high energy neutron irradiation facility, ESNIT (energy selective neutron irradiation test facility), is summarized. Technological survey and feasibility studies of ESNIT have continued since 1988. The results of technical studies of the accelerator, the target and the experimental systems in ESNIT program were reviewed by an International Advisory Committee in February 1993. Recommendations for future R and D on ESNIT program are also summarized in this paper. ((orig.))

  17. Intense neutron irradiation facility for fusion reactor materials

    Energy Technology Data Exchange (ETDEWEB)

    Noda, Kenji; Oyama, Yukio; Kato, Yoshio; Sugimoto, Masayoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-03-01

    Technical R and D of d-Li stripping type neutron irradiation facilities for development of fusion reactor materials was carried out in Fusion Materials Irradiation Test Facility (FMIT) project and Energy Selective Neutron Irradiation Test Facility (ESNIT) program. Conceptual design activity (CDA) of International Fusion Materials Irradiation Facility (IFMIF), of which concept is an advanced version of FMIT and ESNIT concepts, are being performed. Progress of users` requirements and characteristics of irradiation fields in such neutron irradiation facilities, and outline of baseline conceptual design of IFMIF were described. (author)

  18. Design of a high-flux test assembly for the Fusion Materials Irradiation Test Facility

    International Nuclear Information System (INIS)

    Opperman, E.K.; Vogel, M.A.

    1982-01-01

    The Fusion Material Test Facility (FMIT) will provide a high flux fusion-like neutron environment in which a variety of structural and non-structural materials irradiations can be conducted. The FMIT experiments, called test assemblies, that are subjected to the highest neutron flux magnitudes and associated heating rates will require forced convection liquid metal cooling systems to remove the neutron deposited power and maintain test specimens at uniform temperatures. A brief description of the FMIT facility and experimental areas is given with emphasis on the design, capabilities and handling of the high flux test assembly

  19. East Area Irradiation Test Facility: Preliminary FLUKA calculations

    CERN Document Server

    Lebbos, E; Calviani, M; Gatignon, L; Glaser, M; Moll, M; CERN. Geneva. ATS Department

    2011-01-01

    In the framework of the Radiation to Electronics (R2E) mitigation project, the testing of electronic equipment in a radiation field similar to the one occurring in the LHC tunnel and shielded areas to study its sensitivity to single even upsets (SEU) is one of the main topics. Adequate irradiation test facilities are therefore required, and one installation is under consideration in the framework of the PS East area renovation activity. FLUKA Monte Carlo calculations were performed in order to estimate the radiation field which could be obtained in a mixed field facility using the slowly extracted 24 GeV/c proton beam from the PS. The prompt ambient dose equivalent as well as the equivalent residual dose rate after operation was also studied and results of simulations are presented in this report.

  20. The Birmingham Irradiation Facility

    International Nuclear Information System (INIS)

    Dervan, P.; French, R.; Hodgson, P.; Marin-Reyes, H.; Wilson, J.

    2013-01-01

    At the end of 2012 the proton irradiation facility at the CERN PS will shut down for two years. With this in mind, we have been developing a new ATLAS scanning facility at the University of Birmingham Medical Physics cyclotron. With proton beams of energy approximately 30 MeV, fluences corresponding to those of the upgraded Large Hadron Collider (HL-LHC) can be reached conveniently. The facility can be used to irradiate silicon sensors, optical components and mechanical structures (e.g. carbon fibre sandwiches) for the LHC upgrade programme. Irradiations of silicon sensors can be carried out in a temperature controlled cold box that can be scanned through the beam. The facility is described in detail along with the first tests carried out with mini (1×1 cm 2 ) silicon sensors

  1. The Birmingham Irradiation Facility

    CERN Document Server

    Dervan, P; Hodgson, P; Marin-Reyes, H; Wilson, J

    2013-01-01

    At the end of 2012 the proton irradiation facility at the CERN PS [1] will shut down for two years. With this in mind, we have been developing a new ATLAS scanning facility at the University of Birmingham Medical Physics cyclotron. With proton beams of energy approximately 30 MeV, fluences corresponding to those of the upgraded Large Hadron Collider (HL-LHC) can be reached conveniently. The facility can be used to irradiate silicon sensors, optical components and mechanical structures (e.g. carbon fibre sandwiches) for the LHC upgrade programme. Irradiations of silicon sensors can be carried out in a temperature controlled cold box that can be scanned through the beam. The facility is described in detail along with the first tests carried out with mini (1 x 1 cm^2 ) silicon sensors.

  2. URAM-2 Cryogenic Irradiation Facility

    CERN Document Server

    Shabalin, E P; Kulikov, S A; Kulagin, E N; Melihov, V V; Belyakov, A A; Golovanov, L B; Borzunov, Yu T; Konstantinov, V I; Androsov, A V

    2002-01-01

    The URAM-2 irradiation facility has been built and mounted at the channel No. 3 of the IBR-2 reactor. It was constructed for study of radiolysis effects by fast neutron irradiation in some suitable for effective cold neutron production materials (namely: solid methane, methane hydrate, water ice, etc.). The facility cooling system is based on using liquid helium as a coolant material. The original charging block of the rig allows the samples to be loaded by condensing gas into irradiation cavity or by charging beads of ice prepared before. Preliminary tests for each facility block and assembling them at the working position were carried out. Use of the facility for study accumulation of chemical energy under irradiation at low temperature in materials mentioned above and its spontaneous release was started.

  3. Bulk-shield design for the Fusion Materials Irradiation Test facility

    International Nuclear Information System (INIS)

    Carter, L.L.; Mann, F.M.; Morford, R.J.; Johnson, D.L.; Huang, S.T.

    1982-07-01

    The accelerator-based Fusion Materials Irradiation Test (FMIT) facility will provide a high-fluence, fusion-like radiation environment for the testing of materials. While the neutron spectrum produced in the forward direction by the 35 MeV deuterons incident upon a flowing lithium target is characterized by a broad peak around 14 MeV, a high energy tail extends up to about 50 MeV. Some shield design considerations are reviewed

  4. A spallation-based irradiation test facility for fusion and future fission materials

    CERN Document Server

    Samec, K; Kadi, Y; Luis, R; Romanets, Y; Behzad, M; Aleksan, R; Bousson, S

    2014-01-01

    The EU’s FP7 TIARA program for developing accelerator-based facilities has recently demonstrated the unique capabilities of a compact and powerful spallation source for irradiating advanced nuclear materials. The spectrum and intensity of the neutron flux produced in the proposed facility fulfils the requirements of the DEMO fusion reactor for ITER, ADS reactors and also Gen III / IV reactors. Test conditions can be modulated, covering temperature from 400 to 550°C, liquid metal corrosion, cyclical or static stress up to 500 MPa and neutron/proton irradiation damage of up to 25 DPA per annum. The entire “TMIF” facility fits inside a cube 2 metres on a side, and is dimensioned for an accelerator beam power of 100 kW, thus reducing costs and offering great versatility and flexibility.

  5. Status on the construction of the fuel irradiation test facility

    International Nuclear Information System (INIS)

    Park, Kook Nam; Sim, Bong Shick; Lee, Chung Young; Yoo, Seong Yeon

    2005-01-01

    As a facility to examine general performance of nuclear fuel under irradiation condition in HANARO, Fuel Test Loop(FTL) has been developed which can accommodate 3 fuel pins at the core irradiation hole(IR1 hole) taking consideration user's test requirement. 3-Pin FTL consists of In-Pile Test Section (IPS) and Out-of- Pile System (OPS). Test condition in IPS such as pressure, temperature and the water quality, can be controlled by OPS. 3-Pin FTL Conceptual design was set up in 2001 and had completed detail design including a design requirement and basic Piping and Instrument Diagram (P and ID) in 2004. The safety analysis report was prepared and submitted in early 2005 to the regulatory body(KINS) for review and approval of FTL. In 2005, the development team is going to purchase and manufacture hardware and make a contract for construction work. In 2006, the development team is going to install an FTL system performance test shall be done as a part of commissioning. After a 3-Pin FTL development which is expected to be finished by the 2007, FTL will be used for the irradiation test of the new PWR-type fuel and the usage of HANARO will be enhanced

  6. Irradiation Facilities at CERN

    CERN Document Server

    Gkotse, Blerina; Carbonez, Pierre; Danzeca, Salvatore; Fabich, Adrian; Garcia, Alia, Ruben; Glaser, Maurice; Gorine, Georgi; Jaekel, Martin, Richard; Mateu,Suau, Isidre; Pezzullo, Giuseppe; Pozzi, Fabio; Ravotti, Federico; Silari, Marco; Tali, Maris

    2017-01-01

    CERN provides unique irradiation facilities for applications in many scientific fields. This paper summarizes the facilities currently operating for proton, gamma, mixed-field and electron irradiations, including their main usage, characteristics and information about their operation. The new CERN irradiation facilities database is also presented. This includes not only CERN facilities but also irradiation facilities available worldwide.

  7. A spallation-based irradiation test facility for fusion and future fission materials

    International Nuclear Information System (INIS)

    Samec, K.; Fusco, Y.; Kadi, Y.; Luis, R.; Romanets, Y.; Behzad, M.; Aleksan, R.; Bousson, S.

    2014-01-01

    The EU's FP7 TIARA program for developing accelerator-based facilities has recently demonstrated the unique capabilities of a compact and powerful spallation source for irradiating advanced nuclear materials. The spectrum and intensity of the neutron flux produced in the proposed facility fulfils the requirements of the proposed DEMO fusion reactor, ADS reactors and also Gen III / IV reactors. Test conditions can be modulated, covering temperature from 400 to 550 deg. C, liquid metal corrosion, cyclical or static stress up to 500 MPa and neutron/proton irradiation damage of up to 25 DPA per annum over a volume occupying one litre. The entire 'TMIF' facility fits inside a cube 2 metres on a side, and is dimensioned for an accelerator beam power of 100 kW, thus reducing costs and offering great versatility and flexibility. (authors)

  8. Progress towards a new Canadian irradiation-research facility

    International Nuclear Information System (INIS)

    Lee, A.G.; Lidstone, R.F.

    1993-01-01

    As reported at the second meeting of the International Group on Research Reactors, Atomic Energy of Canada Limited (AECL) is evaluating its options for future irradiation facilities. During the past year significant progress has been made towards achieving consensus on the irradiation requirements for AECL's major research programs and interpreting those requirements in terms of desirable characteristics for experimental facilities in a research reactor. The next stage of the study involves identifying near-term and long-term options for irradiation-research facilities to meet the requirements. The near-term options include assessing the availability of the NRU reactor and the capabilities of existing research reactors. The long-term options include developing a new irradiation-research facility by adapting the technology base for the MAPLE-X10 reactor design. Because materials testing in support of CANDU power reactors dominates AECL's irradiation requirements, the new reactor concept is called the MAPLE Materials Testing Reactor (MAPLE-MTR). Parametric physics and engineering studies are in progress on alternative MAPLE-MTR configurations to assess the capabilities for the following types of test facilities: - fast-neutron sites, that accommodate materials-irradiation assemblies, - small-diameter vertical fuel test loops that accommodate multielement assemblies, - large-diameter vertical fuel test loops, each able to hold one or more CANDU fuel bundles, - horizontal test loops, each able to hold full-size CANDU fuel bundles or small-diameter multi-element assemblies, and - horizontal beam tubes

  9. International fusion materials irradiation facility and neutronic calculations for its test modules

    International Nuclear Information System (INIS)

    Sokcic-Kostic, M.

    1997-01-01

    The International Fusion Material Irradiation Facility (IFMIF) is a projected high intensity neutron source for material testing. Neutron transport calculations for the IFMIF project are performed for variety of here explained reasons. The results of MCNP neutronic calculations for IFMIF test modules with NaK and He cooled high flux test cells are presented in this paper. (author). 3 refs., 2 figs., 3 tabs

  10. New electron beam facility for irradiated plasma facing materials testing in hot cell

    International Nuclear Information System (INIS)

    Sakamoto, N.; Kawamura, H.; Akiba, M.

    1995-01-01

    Since plasma facing components such as the first wall and the divertor for the next step fusion reactors are exposed to high heat loads and high energy neutron flux generated by the plasma, it is urgent to develop of plasma facing components which can resist these. Then, we have established electron beam heat facility (open-quotes OHBISclose quotes, Oarai Hot-cell electron Beam Irradiating System) at a hot cell in JMTR (Japan Materials Testing Reactor) hot laboratory in order to estimate thermal shock resistivity of plasma facing materials and heat removal capabilities of divertor elements under steady state heating. In this facility, irradiated plasma facing materials (beryllium, carbon based materials and so on) and divertor elements can be treated. This facility consists of an electron beam unit with the maximum beam power of 50kW and the vacuum vessel. The acceleration voltage and the maximum beam current are 30kV (constant) and 1.7A, respectively. The loading time of electron beam is more than 0.1ms. The shape of vacuum vessel is cylindrical, and the mainly dimensions are 500mm in inner diameter, 1000mm in height. The ultimate vacuum of this vessel is 1 x 10 -4 Pa. At present, the facility for thermal shock test has been established in a hot cell. And performance estimation on the electron beam is being conducted. Presently, the devices for heat loading tests under steady state will be added to this facility

  11. Installation of the water environment irradiation facility for the IASCC research under the BWR irradiation environment (1)

    International Nuclear Information System (INIS)

    Okada, Yuji; Magome, Hirokatsu; Hanawa, Hiroshi; Ohmi, Masao; Kanno, Masaru; Iida, Kazuhiro; Ando, Hitoshi; Shibata, Mitsunobu; Yonekawa, Akihisa; Ueda, Haruyasu

    2013-10-01

    In Japan Atomic Energy Agency, in order to solve the problem in the long-term operation of a light water reactor, preparation which does the irradiation experiment of light-water reactor fuel and material is advanced. JMTR stopped after the 165th operation cycle in August 2006, and is advancing renewal of the irradiation facility towards re-operation. This material irradiation test facility and power ramping test facility for doing the neutron irradiation test of the fuel and material for light water reactors is scheduled to be manufactured and installed between the 2008 fiscal year and the 2012 fiscal year. This report summarizes manufacture and installation of the material irradiation test facility for IASCC research carried out from the 2008 fiscal year to the 2010 fiscal year. (author)

  12. Investigation of high flux test module for the international fusion materials irradiation facilities (IFMIF)

    International Nuclear Information System (INIS)

    Miyashita, Makoto; Sugimoto, Masayoshi; Yutani, Toshiaki

    2007-03-01

    This report describes investigation on structure of a high neutron flux test module (HFTM) for the International Fusion Materials Irradiation Facilities (IFMIF). The HFTM is aimed for neutron irradiation of a specimen in a high neutron flux domain of the test cell for irradiation ground of IFMIF. We investigated the overall structure of the HFTM that was able to include specimens in a rig and thermocouple arrangement, an interface of control signal and support structure. Moreover, pressure and the amount of the bend in the module vessel (a rectangular section pressure vessel) were calculated. The module vessel did a rectangular section from limitation of a high neutron flux domain. Also, we investigated damage of thermocouples under neutron irradiation, which was a temperature sensor of irradiation materials temperature control demanded high precision. Based on these results, drawings on the HTFM structure. (author)

  13. Shield design for the Fusion Materials Irradiation Test facility

    International Nuclear Information System (INIS)

    Carter, L.L.; Mann, F.M.; Morford, R.J.; Wilcox, A.D.; Johnson, D.L.; Huang, S.T.

    1983-03-01

    The shield design for the Fusion Materials Irradiation Test facility is based upon one-, two- and three-dimensional transport calculations with experimental measurements utilized to refine the nuclear data including the neutron cross sections from 20 to 50 MeV and the gamma ray and neutron source terms. The high energy neutrons and deuterons produce activation products from the numerous reactions that are kinematically allowed. The analyses for both beam-on and beam-off (from the activation products) conditions have required extensive nuclear data libraries and the utilization of Monte Carlo, discrete ordinates, point kernel and auxiliary computer codes

  14. Use of EBR-II as a principal fast breeder reactor irradiation test facility in the U.S

    International Nuclear Information System (INIS)

    Staker, R.G.; Seim, O.S.; Beck, W.N.; Golden, G.H.; Walters, L.C.

    1975-01-01

    The EBR-II as originally designed and operated by the Argonne National Laboratory was successful in demonstrating the operation of a sodium-cooled fast breeder power plant with a closed fuel reprocessing cycle. Subsequent operation has been as an experimental facility where thousands of irradiation tests have been performed. Conversion to this application entailed the design and fabrication of special irradiation subassemblies for in-core irradiations, additions to existing facilities for out-of-core irradiations, and additions to existing facilities for out-of-core experiments. Experimental subassemblies now constitute about one third of the core, and changes in the core configuration occur about monthly, requiring neutronic and thermal-hydraulics analyses and monitoring of the reactor dynamic behavior. The surveillance programs provided a wealth of information on irradiation induced swelling and creep, in-reactor fracture behavior, and the compatibility of materials with liquid sodium. (U.S.)

  15. New facility for post irradiation examination of neutron irradiated beryllium

    International Nuclear Information System (INIS)

    Ishitsuka, Etsuo; Kawamura, Hiroshi

    1995-01-01

    Beryllium is expected as a neutron multiplier and plasma facing materials in the fusion reactor, and the neutron irradiation data on properties of beryllium up to 800 degrees C need for the engineering design. The acquisition of data on the tritium behavior, swelling, thermal and mechanical properties are first priority in ITER design. Facility for the post irradiation examination of neutron irradiated beryllium was constructed in the hot laboratory of Japan Materials Testing Reactor to get the engineering design data mentioned above. This facility consist of the four glove boxes, dry air supplier, tritium monitoring and removal system, storage box of neutron irradiated samples. Beryllium handling are restricted by the amount of tritium;7.4 GBq/day and 60 Co;7.4 MBq/day

  16. New electron beam facility for irradiated plasma facing materials testing in hot cell

    International Nuclear Information System (INIS)

    Shimakawa, S.; Akiba, M.; Kawamura, H.

    1996-01-01

    Since plasma facing components such as the first wall and the divertor for the next step fusion reactors are exposed to high heat loads and high energy neutron flux generated by the plasma, it is urgent to develop plasma facing components which can resist these. We have established electron beam heat facility ('OHBIS', Oarai hot-cell electron beam irradiating system) at a hot cell in JMTR (Japan materials testing reactor) hot laboratory in order to estimate thermal shock resistivity of plasma facing materials and heat removal capabilities of divertor elements under steady state heating. In this facility, irradiated plasma facing materials (beryllium, carbon based materials and so on) and divertor elements can be treated. This facility consists of an electron beam unit with the maximum beam power of 50 kW and the vacuum vessel. The acceleration voltage and the maximum beam current are 30 kV (constant) and 1.7 A, respectively. The loading time of the electron beam is more than 0.1 ms. The shape of vacuum vessel is cylindrical, and the main dimensions are 500 mm in inside diameter, 1000 mm in height. The ultimate vacuum of this vessel is 1 x 10 -4 Pa. At present, the facility for the thermal shock test has been established in a hot cell. The performance of the electron beam is being evaluated at this time. In the future, the equipment for conducting static heat loadings will be incorporated into the facility. (orig.)

  17. Defocusing beam line design for an irradiation facility at the TAEA SANAEM Proton Accelerator Facility

    Science.gov (United States)

    Gencer, A.; Demirköz, B.; Efthymiopoulos, I.; Yiğitoğlu, M.

    2016-07-01

    Electronic components must be tested to ensure reliable performance in high radiation environments such as Hi-Limu LHC and space. We propose a defocusing beam line to perform proton irradiation tests in Turkey. The Turkish Atomic Energy Authority SANAEM Proton Accelerator Facility was inaugurated in May 2012 for radioisotope production. The facility has also an R&D room for research purposes. The accelerator produces protons with 30 MeV kinetic energy and the beam current is variable between 10 μA and 1.2 mA. The beam kinetic energy is suitable for irradiation tests, however the beam current is high and therefore the flux must be lowered. We plan to build a defocusing beam line (DBL) in order to enlarge the beam size, reduce the flux to match the required specifications for the irradiation tests. Current design includes the beam transport and the final focusing magnets to blow up the beam. Scattering foils and a collimator is placed for the reduction of the beam flux. The DBL is designed to provide fluxes between 107 p /cm2 / s and 109 p /cm2 / s for performing irradiation tests in an area of 15.4 cm × 21.5 cm. The facility will be the first irradiation facility of its kind in Turkey.

  18. Idaho National Engineering Laboratory irradiation facilities and their applications

    International Nuclear Information System (INIS)

    Gupta, V.P.; Herring, J.S.; Korenke, R.E.; Harker, Y.D.

    1986-05-01

    Although there is a growing need for neutron and gamma irradiation by governmental and industrial organizations in the United States and in other countries, the number of facilities providing such irradiations are limited. At the Idaho National Engineering Laboratory, there are several unique irradiation facilities producing high neutron and gamma radiation environments. These facilities could be readily used for nuclear research, materials testing, radiation hardening studies on electronic components/circuitry and sensors, and production of neutron transmutation doped (NTD) silicon and special radioisotopes. In addition, a neutron radiography unit, suitable for examining irradiated materials and assemblies, is also available. This report provides a description of the irradiation facilities and the neutron radiography unit as well as examples of their unique applications

  19. Neutron irradiation facility and its characteristics

    International Nuclear Information System (INIS)

    Oyama, Yukio; Noda, Kenji

    1995-01-01

    A neutron irradiation facility utilizing spallation reactions with high energy protons is conceived as one of the facilities in 'Proton Engineering center (PEC)' proposed at JAERI. Characteristics of neutron irradiation field of the facility for material irradiation studies are described in terms of material damage parameters, influence of the pulse irradiation, irradiation environments other than neutronics features, etc., comparing with the other sorts of neutron irradiation facilities. Some perspectives for materials irradiation studies using PEC are presented. (author)

  20. The present situation of the irradiation application industry and irradiation facilities in Japan

    International Nuclear Information System (INIS)

    Mizusawa, K.; Baba, T.

    2003-01-01

    The irradiation application industry and irradiation facilities in Japan have been making slow but steady progress for the past 2-3 years. Beside conventional applications, new ones such as carbon fibers and membrane filters have come into the market. There are a lot of new applications about to emerge. PE tubing, already is in the European market, is being evaluated by end users in Japan. Cleaning of dioxin in exhaust gas was successfully tested at a pilot plant. Cross-linked PTFE and polyamide are waiting customers' evaluations as an engineering plastic. Surface cross-linking of artificial polycarbonate teeth has yielded remarkable experimental results. Cross-linking of polycaprolactone will be useful for biodegradable products. Being aware of the future growth of irradiation industry, contract service providers opened new facilities or increased their capability. Beside in-house facilities, there are now three Co-60 facilities and nine EB facilities available for contract irradiation in Japan

  1. Development of new irradiation facility for BWR safety research

    International Nuclear Information System (INIS)

    Okada, Yuji; Magome, Hirokatsu; Iida, Kazuhiro; Hanawa, Hiroshi; Ohmi, Masao

    2013-01-01

    In JAEA (Japan Atomic Energy Agency), about the irradiation embrittlement of the reactor pressure vessel and the stress corrosion cracking of reactor core composition apparatus concerning the long-term use of the light water reactor (BWR), in order to check the influence of the temperature, pressure, and water quality, etc on BWR condition. The water environmental control facility which performs irradiation assisted stress corrosion-cracking (IASCC) evaluation under BWR irradiation environment was fabricated in JMTR (Japan Materials Testing Reactor). This report is described the outline of manufacture of the water environmental control facility for doing an irradiation test using the saturation temperature capsule after JMTR re-operation. (author)

  2. National Low-Temperature Neutron-Irradiation Facility

    International Nuclear Information System (INIS)

    Coltman, R.R. Jr.; Klabunde, C.E.; Young, F.W. Jr.

    1983-08-01

    The Materials Sciences Division of the United States Department of Energy will establish a National Low Temperature Neutron Irradiation Facility (NLTNIF) which will utilize the Bulk Shielding Reactor (BSR) located at Oak Ridge National Laboratory. The facility will provide high radiation intensities and special environmental and testing conditions for qualified experiments at no cost to users. This report describes the planned experimental capabilities of the new facility

  3. Irradiation facilities at the Los Alamos Meson Physics Facility

    International Nuclear Information System (INIS)

    Sandberg, V.

    1990-01-01

    The irradiation facilities for testing SSC components and detector systems are described. Very high intensity proton, neutron, and pion fluxes are available with beam kinetic energies of up to 800 MeV. 4 refs., 12 figs., 2 tabs

  4. The PIREX proton irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Victoria, M. [Association EURATOM, Villigen (Switzerland)

    1995-10-01

    The proton Irradiation Experiment (PIREX) is a materials irradiation facility installed in a beam line of the 590 MeV proton accelerator at the Paul Scherrer Institute. Its main purpose is the testing of candidate materials for fusion reactor components. Protons of this energy produce simultaneously displacement damage and spallation products, amongst them helium and can therefore simulate any possible synergistic effects of damage and helium, that would be produced by the fusion neutrons.

  5. The PIREX proton irradiation facility

    International Nuclear Information System (INIS)

    Victoria, M.

    1995-01-01

    The proton Irradiation Experiment (PIREX) is a materials irradiation facility installed in a beam line of the 590 MeV proton accelerator at the Paul Scherrer Institute. Its main purpose is the testing of candidate materials for fusion reactor components. Protons of this energy produce simultaneously displacement damage and spallation products, amongst them helium and can therefore simulate any possible synergistic effects of damage and helium, that would be produced by the fusion neutrons

  6. Proposed rf system for the fusion materials irradiation test facility

    International Nuclear Information System (INIS)

    Fazio, M.V.; Johnson, H.P.; Hoffert, W.J.; Boyd, T.J.

    1979-01-01

    Preliminary rf system design for the accelerator portion of the Fusion Materials Irradiation Test (FMIT) Facility is in progress. The 35-MeV, 100-mA, cw deuteron beam will require 6.3 MW rf power at 80 MHz. Initial testing indicates the EIMAC 8973 tetrode is the most suitable final amplifier tube for each of a series of 15 amplifier chains operating at 0.5-MW output. To satisfy the beam dynamics requirements for particle acceleration and to minimize beam spill, each amplifier output must be controlled to +-1 0 in phase and the field amplitude in the tanks must be held within a 1% tolerance. These tolerances put stringent demands on the rf phase and amplitude control system

  7. Validity and Utilization of the Out-Pile Testing Facilities at HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee-Nam; Cho, Man-Soon; Yang, Sung-Woo; Shin, Yoon-Taek; Park, Seng-Jae; Jun, Byung-Hyuk; Kim, Myong-Seop [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Various neutron irradiation facilities such as rabbit irradiation facilities, loop facilities and the capsule irradiation facilities for irradiation tests of nuclear materials, fuels and radioisotope products have been developed at HANARO. Among these irradiation facilities, the capsule is the most useful device for coping with the various test requirements at HANARO. To support the national research and development programs on nuclear reactors and the nuclear fuel cycle technology in Korea, new irradiation capsules have been developed and actively utilized for the irradiation tests requested by numerous users. The environmental conditions for these reactors are generally beyond present day reactor technology, especially regarding the higher neutron fluence and higher operating temperature. To effectively support the national R and Ds relevant to the future nuclear systems, the development of advanced irradiation technologies concerning higher neutron fluence and irradiation temperature are being preferentially developed at HANARO. The utilization of the out-pile testing facilities to satisfy the criteria of safety evaluation for a new device installed in the core of HANARO was summarized. In addition, the validity of the out-pile testing facilities was evaluated and proved to be effective for verifying the integrity of irradiation capsule.

  8. Validity and Utilization of the Out-Pile Testing Facilities at HANARO

    International Nuclear Information System (INIS)

    Choo, Kee-Nam; Cho, Man-Soon; Yang, Sung-Woo; Shin, Yoon-Taek; Park, Seng-Jae; Jun, Byung-Hyuk; Kim, Myong-Seop

    2016-01-01

    Various neutron irradiation facilities such as rabbit irradiation facilities, loop facilities and the capsule irradiation facilities for irradiation tests of nuclear materials, fuels and radioisotope products have been developed at HANARO. Among these irradiation facilities, the capsule is the most useful device for coping with the various test requirements at HANARO. To support the national research and development programs on nuclear reactors and the nuclear fuel cycle technology in Korea, new irradiation capsules have been developed and actively utilized for the irradiation tests requested by numerous users. The environmental conditions for these reactors are generally beyond present day reactor technology, especially regarding the higher neutron fluence and higher operating temperature. To effectively support the national R and Ds relevant to the future nuclear systems, the development of advanced irradiation technologies concerning higher neutron fluence and irradiation temperature are being preferentially developed at HANARO. The utilization of the out-pile testing facilities to satisfy the criteria of safety evaluation for a new device installed in the core of HANARO was summarized. In addition, the validity of the out-pile testing facilities was evaluated and proved to be effective for verifying the integrity of irradiation capsule

  9. Irradiation test of the HCAL Forward and Endcap upgrade electronics at the CHARM facility at CERN

    CERN Document Server

    AUTHOR|(CDS)2068434; Costanza, Francesco; Karakaya, Tugba; Sahin, Mehmet Ozgur; Lincoln, Don; Strobbe, Nadja; Kaminskiy, Alexander; Tlisov, Danila; Wang, Yanchu; Hirschauer, James Francis

    2016-01-01

    In the period October 21 – 28, 2015, the CMS HCAL group did a radiation tolerance study for the Phase I Upgrade HF, HE and HB front end electronics. The test was conducted at the CERN CHARM facility, which is a mixed field radiation facility. No permanent damages were observed. Effects observed during the irradiation are presented.

  10. Practical design of gamma irradiation facility

    International Nuclear Information System (INIS)

    Sugimoto, Sen-ichi

    1976-01-01

    In this report, it is intended to describe mainly the multi-purpose irradiation facilities which carry out the consigned irradiation for the sterilization of medical apparatuses, which is most of the demand of gamma irradiation in Japan. Gamma irradiation criterion is summed up to that ''Apply the specified dose properly and uniformly to product cases and be economic.'' Though the establishment of the design standard for irradiation facilities is not easy and is not solve simply, the factors to be considered in the design are as follows: (1) mechanism safety, (2) multipurpose irradiation structure, (3) irradiation criteria and practice, (4) efficiency of radiation source utilization and related problems, and (5) economical merit. Irradiation facilities are generally itemized as follows: irradiation equipments, radiation source-storing facility, package carrier, radiation source-driving equipments, facilities for safety and operational management and others. Examples and their characteristics are reported for the facilities of Japan Radio-isotope Irradiation Cooperative Association and Radie Industries Ltd. Expenses for construction, processing and radiation sources are shown on the basis of a few references, and the cost trially calculated under a certain presumptive condition is given. (Wakatsuki, Y.)

  11. Installation of the water environment irradiation facility for the IASCC research under the BWR/PWR irradiation environment (2)

    International Nuclear Information System (INIS)

    Magome, Hirokatsu; Okada, Yuji; Hanawa, Hiroshi; Sakuta, Yoshiyuki; Kanno, Masaru; Iida, Kazuhiro; Ando, Hitoshi; Yonekawa, Akihisa; Ueda, Haruyasu; Shibata, Mitsunobu

    2014-07-01

    In Japan Atomic Energy Agency, in order to solve the problem in the long-term operation of a light water reactor, preparation which does the irradiation experiment of light-water reactor fuel and material was advanced. JMTR stopped after the 165th operation cycle in August 2006, and is advancing renewal of the irradiation facility towards re-operation. The material irradiation test facility was installed from 2008 fiscal year to 2012 fiscal year in JMTR. This report summarizes manufacture and installation of the material irradiation test facility for IASCC research carried out from 2012 to 2014 in the follow-up report reported before (JAEA-Technology 2013-019). (author)

  12. Monte Carlo studies for irradiation process planning at the Portuguese gamma irradiation facility

    International Nuclear Information System (INIS)

    Oliveira, C.; Salgado, J.; Botelho, M.L.M. Luisa; Ferreira, L.M.

    2000-01-01

    The paper describes a Monte Carlo study for planning the irradiation of test samples for microbiological validation of distinct products in the Portuguese Gamma Irradiation Facility. Three different irradiation geometries have been used. Simulated and experimental results are compared and good agreement is observed. It is shown that Monte Carlo simulation improves process understanding, predicts absorbed dose distributions and calculates dose uniformity in different products. Based on these results, irradiation planning of the product can be performed

  13. Preliminary Beam Irradiation Test for RI Production Targets at KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Pil; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub; Seol, Kyung Tae; Song, Young Gi; Kim, Dae Il; Jung, Myung Hwan; Kim, Kye Ryung; Min, Yi Sub [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The new beamline and target irradiation facility has been constructed for the production of therapeutic radio-isotope. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. For the facility commissioning, the irradiation test for the prototype-target was conducted to confirm the feasibility of radio-isotope production, the proto-type targets are made of RbCl pellet and the natural Zn metal for Sr-82 and Cu-67 production respectively, In this paper, an introduction to the RI production targetry system and the results of the preliminary beam irradiation test are discussed. the low-flux beam irradiation tests for proto-type RI target have been conducted. As a result of the beam irradiation tests, we could obtain the evidence of Sr-82 and Cu-67 production, have confirmed the feasibility of Sr-82 and Cu-67 production at KOMAC RI production facility.

  14. Preliminary Beam Irradiation Test for RI Production Targets at KOMAC

    International Nuclear Information System (INIS)

    Yoon, Sang Pil; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub; Seol, Kyung Tae; Song, Young Gi; Kim, Dae Il; Jung, Myung Hwan; Kim, Kye Ryung; Min, Yi Sub

    2016-01-01

    The new beamline and target irradiation facility has been constructed for the production of therapeutic radio-isotope. Sr-82 and Cu-67 were selected as the target isotope in this facility, they are promising isotope for the PET imaging and cancer therapy. For the facility commissioning, the irradiation test for the prototype-target was conducted to confirm the feasibility of radio-isotope production, the proto-type targets are made of RbCl pellet and the natural Zn metal for Sr-82 and Cu-67 production respectively, In this paper, an introduction to the RI production targetry system and the results of the preliminary beam irradiation test are discussed. the low-flux beam irradiation tests for proto-type RI target have been conducted. As a result of the beam irradiation tests, we could obtain the evidence of Sr-82 and Cu-67 production, have confirmed the feasibility of Sr-82 and Cu-67 production at KOMAC RI production facility

  15. Development of the flow control irradiation facility for JOYO

    International Nuclear Information System (INIS)

    Soroi, Masatoshi; Miyakawa, Shun-ichi

    1998-05-01

    This report describes the present situation and problems with the development of the flow control irradiation facility (FLORA). The purpose of FLORA is to run the cladding breach (RTCB) irradiation test under loss of flow conditions in the experimental fast reactor 'JOYO'. FLORA is a facility like FPTF (Fuel Performance Test Facility) plus BFTF (Breached Fuel Test Facility) in EBR-II, USA. The technical feature of FLORA is its annular linear induction pump (A-LIP), which was developed in response to a need identified through the experiences in the mechanical flow control of FPTF. We have already designed the basic system facility of FLORA for the JOYO MK-II core. However, to put FLORA to practical use in the future, we have to confirm the stability of the JOYO MK-III core condition, solve problems and improve the design. We are going to freeze and review the FLORA project, taking into consideration the fuel development situation and the research project of JOYO MK-III core. (J.P.N.)

  16. Facts about food irradiation: Safety of irradiation facilities

    International Nuclear Information System (INIS)

    1991-01-01

    This fact sheet considers the safety of industrial irradiation facilities. Although there have been accidents, none of them has endangered public health or environmental safety, and the radiation processing industry is considered to have a very good safety record. Gamma irradiators do not produce radioactive waste, and the radiation sources at the facilities cannot explode nor in any other way release radioactivity into the environment. 3 refs

  17. FFTF [Fast Flux Test Facility] management

    International Nuclear Information System (INIS)

    Bennett, C.L.

    1986-11-01

    Fuel Management at the Fast Flux Test Facility (FFTF) involves more than just the usual ex-core and in-core management of standard fuel and non-fuel components between storage locations and within the core since it is primarily an irradiation test facility. This mission involves testing an ever increasing variety of fueled and non-fueled experiments, each having unique requirements on the reactor core as well as having its own individual impact on the reload design. This paper describes the fuel management process used by the Westinghouse Hanford Company Core Engineering group that has led to the successful reload design of nine operating cycles and the irradiation of over 120 tests

  18. Fuels and materials testing capabilities in Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Baker, R.B.; Chastain, S.A.; Culley, G.E.; Ethridge, J.L.; Lovell, A.J.; Newland, D.J.; Pember, L.A.; Puigh, R.J.; Waltar, A.E.

    1989-01-01

    The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test assembly (FOTA), closed loop in-reactor assembly (CLIRA), and other special fuel assemblies. An interim examination and maintenance cell (FFTF/IEM cell) and other hot cells are used for nondestructive/destructive tests and physical/mechanical properties test of material after irradiation. (N.K.)

  19. Results from the CDE phase activity on neutron dosimetry for the international fusion materials irradiation facility test cell

    CERN Document Server

    Esposito, B; Maruccia, G; Petrizzi, L; Bignon, G; Blandin, C; Chauffriat, S; Lebrun, A; Recroix, H; Trapp, J P; Kaschuck, Y

    2000-01-01

    The international fusion materials irradiation facility (IFMIF) project deals with the study of an accelerator-based, deuterium-lithium source, producing high energy neutrons at sufficient intensity and irradiation volume to test samples of candidate materials for fusion energy reactors. IFMIF would also provide calibration and validation of data from fission reactor and other accelerator based irradiation tests. This paper describes the activity on neutron/gamma dosimetry (necessary for the characterization of the specimens' irradiation) performed in the frame of the IFMIF conceptual design evaluation (CDE) neutronics tasks. During the previous phase (conceptual design activity (CDA)) the multifoil activation method was proposed for the measurement of the neutron fluence and spectrum and a set of suitable foils was defined. The cross section variances and covariances of this set of foils have now been used for tests on the sensitivity of the IFMIF neutron spectrum determination to cross section uncertainties...

  20. Design Study and Optimization of Irradiation Facilities for Detector and Accelerator Equipment Testing in the SPS North Area at CERN

    CERN Document Server

    AUTHOR|(CDS)2079748; Stekl, Ivan

    Due to increasing performance of LHC during the last years, the strong need of new detector and electronic equipment test areas at CERN appeared from user communities. This thesis reports on two test facilities: GIF++ and H4IRRAD. GIF++, an upgrade of GIF facility, is a combined high-intensity gamma and particle beam irradiation facility for testing detectors for LHC. It combines a high-rate 137Cs source, providing photons with energy of 662 keV, together with the high-energy secondary particle beam from SPS. H4IRRAD is a new mixed-field irradiation area, designed for testing LHC electronic equipment for radiation damage effects. In particular, large volume assemblies such as full electronic racks of high current power converters can be tested. The area uses alternatively an attenuated primary 400 GeV/c proton beam from SPS, or a secondary, mainly proton, beam of 280 GeV/c directed towards a copper target. Different shielding layers are used to reproduce a radiation field similar to the LHC “tunnel” and �...

  1. Assessment of the gas dynamic trap mirror facility as intense neutron source for fusion material test irradiations

    International Nuclear Information System (INIS)

    Fischer, U.; Moeslang, A.; Ivanov, A.A.

    2000-01-01

    The gas dynamic trap (GDT) mirror machine has been proposed by the Budker Institute of nuclear physics, Novosibirsk, as a volumetric neutron source for fusion material test irradiations. On the basis of the GDT plasma confinement concept, 14 MeV neutrons are generated at high production rates in the two end sections of the axially symmetrical central mirror cell, serving as suitable irradiation test regions. In this paper, we present an assessment of the GDT as intense neutron source for fusion material test irradiations. This includes comparisons to irradiation conditions in fusion reactor systems (ITER, Demo) and the International Fusion Material Irradiation Facility (IFMIF), as well as a conceptual design for a helium-cooled tubular test assembly elaborated for the largest of the two test zones taking proper account of neutronics, thermal-hydraulic and mechanical aspects. This tubular test assembly incorporates ten rigs of about 200 cm length used for inserting instrumented test capsules with miniaturized specimens taking advantage of the 'small specimen test technology'. The proposed design allows individual temperatures in each of the rigs, and active heating systems inside the capsules ensures specimen temperature stability even during beam-off periods. The major concern is about the maximum achievable dpa accumulation of less than 15 dpa per full power year on the basis of the present design parameters of the GDT neutron source. A design upgrading is proposed to allow for higher neutron wall loadings in the material test regions

  2. Omega: A 24-beam UV irradiation facility

    International Nuclear Information System (INIS)

    Richardson, M.C.; Beich, W.; Delettrez, J.

    1985-01-01

    The authors report on the characterization and performance of the 24-beam Omega laser facility under full third harmonic (351-nm) upconversion. This system provides for the first time a multibeam laser facility for the illumination of spherical targets with UV laser light in symmetric irradiation conditions with energies in the kilojoule range. This facility is capable of providing sufficient irradiation uniformity to test concepts of direct drive laser fusion with UV-driven ablation targets. The results of initial studies of ablatively driven DT-fueled glass microballoon targets will be described. The 24-beam Omega Nd:phosphate glass facility is capable of providing at 1054 nm output powers in excess of 10 TW in short ( 10 4 full system shots to date) irradiation facility with beam synchronism of approx. =3 psec, beam placement accuracy on target of 10 μm, and interbeam energy variance of approx. =2%. From measured target plane intensity distributions, overall illumination uniformity with tangentially focused beams is estimated to be approx. =5%. In 1984, a symmetric set of six beams was upconverted to 351-nm radiation using the polarization-mismatch scheme developed by Craxton. Monolithic cells of 20-cm clear aperture containing both frequency and doubler and tripler type II KDP crystals in index-matching propylene carbonate liquid were incorporated to output of six of the Omega beams with a full set of UV beam diagnostics

  3. International Facility for Food Irradiation Technology

    International Nuclear Information System (INIS)

    Farkas, J.

    1982-01-01

    The International Facility for Food Irradiation Technology (IFFIT) was set up in November 1978 for a period of five years at the Pilot Plant for Food Irradiation, Wageningen, The Netherlands under an Agreement between the FAO, IAEA and the Ministry of Agriculture and Fisheries of the Government of the Netherlands. Under this Agreement, the irradiation facilities, office space and services of the Pilot Plant for Food Irradiation are put at IFFIT's disposal. Also the closely located Research Foundation, ITAL, provides certain facilities and laboratory services within the terms of the Agreement. The FAO and IAEA contribute US-Dollar 25,000. Annually for the duration of IFFIT. (orig.) [de

  4. Electron beam irradiation facility for low to high dose irradiation applications

    International Nuclear Information System (INIS)

    Petwal, V.C.; Wanmode, Yashwant; Verma, Vijay Pal; Bhisikar, Abhay; Dwivedi, Jishnu; Shrivastava, P.; Gupta, P.D.

    2013-01-01

    Electron beam based irradiation facilities are becoming more and more popular over the conventional irradiator facilities due to many inherent advantages such as tunability of beam energy, availability of radiation both in electron mode and X-ray mode, wide range of the dose rate, control of radiation from a ON-OFF switch and other safety related merits. A prototype experimental facility based on electron accelerator has been set-up at RRCAT to meet the low-dose, medium dose and high-dose requirements for radiation processing of food, agricultural and medical products. The facility can be operated in the energy range from 7-10 MeV at variable power level from 0.05-3 kW to meet the dose rate requirement of 100 Gy to kGy. The facility is also equipped with a Bremsstrahlung converter optimized for X-ray irradiation at 7.5 MV. Availability of dose delivery in wide range with precision control and measurement has made the facility an excellent tool for researchers interested in electron/X-ray beam irradiation. A precision dosimetry lab based on alanine EPR and radiochromic film dosimetry system have been established to characterize the radiation field and precise dose measurements. Electron beam scattering technique has been developed to achieve low dose requirement for EB irradiation of various seeds such as groundnut, wheat, soybeans, moong beans, black gram etc. for mutation related studies. This paper describes various features of the facility together with the dosimetric measurements carried out for qualification of the facility and recent irradiation experiments carried out using this facility. (author)

  5. Development status of irradiation devices and instrumentation for material and nuclear fuel irradiation tests in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Sohn, Jae Min; Choo, Kee Nam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-04-15

    The High flux Advanced Neutron Application ReactOr (HANARO), an open-tank-in-pool type reactor, is one of the multi-purpose research reactors in the world. Since the commencement of HANARO's operations in 1995, a significant number of experimental facilities have been developed and installed at HANARO, and continued efforts to develop more facilities are in progress. Owing to the stable operation of the reactor and its frequent utilization, more experimental facilities are being continuously added to satisfy various fields of study and diverse applications. The irradiation testing equipment for nuclear fuels and materials at HANARO can be classified into capsules and the Fuel Test Loop (FTL). Capsules for irradiation tests of nuclear fuels in HANARO have been developed for use under the dry conditions of the coolant and materials at HANARO and are now successfully utilized to perform irradiation tests. The FTL can be used to conduct irradiation testing of a nuclear fuel under the operating conditions of commercial nuclear power plants. During irradiation tests conducted using these capsules in HANARO, instruments such as the thermocouple, Linear Variable Differential Transformer (LVDT), small heater, Fluence Monitor (F/M) and Self-Powered Neutron Detector (SPND) are used to measure various characteristics of the nuclear fuel and irradiated material. This paper describes not only the status of HANARO and the status and perspective of irradiation devices and instrumentation for carrying out nuclear fuel and material tests in HANARO but also some results from instrumentation during irradiation tests

  6. Proposal for an irradiation facility at the TAEK SANAEM Proton Accelerator Facility

    Science.gov (United States)

    Demirköz, B.; Gencer, A.; Kiziloren, D.; Apsimon, R.

    2013-12-01

    Turkish Atomic Energy Authority's (TAEK's) Proton Accelerator Facility in Ankara, Turkey, has been inaugurated in May 2012 and is under the process of being certified for commercial radio-isotope production. Three of the four arms of the 30 MeV cyclotron are being used for radio-isotope production, while the fourth is foreseen for research and development of novel ideas and methods. The cyclotron can vary the beam current between 12 μA and 1.2 mA, sufficient for irradiation tests for semiconductor materials, detectors and devices. We propose to build an irradiation facility in the R&D room of this complex, open for use to the international detector development community.

  7. Utilization of the capsule out-pile test facilities(2000-2003)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M. S.; Oh, J. M.; Cho, Y. G. and others

    2003-06-01

    Two out-pile test facilities were installed and being utilized for the non-irradiation tests outside the HANARO. The names of the facilities are the irradiation equipment design verification test facilities and the one-channel flow test device. In these facilities, the performance test of all capsules manufactured before loading in the HANARO and the design verification test for newly developed capsules were performed. The tests in these facilities include loading/unloading, pressure drop, endurance and vibration test etc. of capsules. In the period 2000{approx}2003, the performance tests for 8 material capsules of 99M-01K{approx}02M-05U were carried out, and the design verification tests of creep and fuel capsules developed newly were performed. For development of the creep capsule, pressure drop measurement, operation test of heater, T/C, LVDT and stress loading test were performed. In the design stage of the fuel capsule, the endurance and vibration test besides the above mentioned tests were carried out for verification of the safe operation during irradiation test in the HANARO. And in-chimeny bracket and the capsule supporting system were fixed and the flow tubes and the handling tools were manufactured for use at the facilities.

  8. High flux materials testing reactor HFR Petten. Characteristics of facilities and standard irradiation devices

    International Nuclear Information System (INIS)

    Roettger, H.; Hardt, P. von der; Tas, A.; Voorbraak, W.P.

    1981-01-01

    For the materials testing reactor HFR some characteristic information is presented. Besides the nuclear data for the experiment positions short descriptions are given of the most important standard facilities for material irradiation and radionuclide production. One paragraph deals with the experimental set-ups for solid state and nuclear structure investigations. The information in this report refers to a core type, which is operational since March 1977. The numerical data compiled have been up-dated to January 1981

  9. Capsule safety analysis of PRTF irradiation facility

    International Nuclear Information System (INIS)

    Suwarto

    2013-01-01

    Power Ramp Test Facility (PRTF) is an irradiation facility used for fuel testing of power reactor. PRTF has a capsule which is a test fuel rod container. During operation, pressurized water of 160 bars flows through in the capsule. Due to the high pressure it should be analyzed the impact of the capsule on reactor core safety. This analysis has purpose to calculate the ability of capsule pressure capacity. The analysis was carried out by calculating pressure capacity. From the calculating results it can be concluded that the capsule with pressure capacity of 438 bars will be safe to prevent the operation pressure of PRTF. (author)

  10. Defocusing beam line design for an irradiation facility at the TAEA SANAEM Proton Accelerator Facility

    CERN Document Server

    Gencer, A.; Efthymiopoulos, I.; Yiğitoğlu, M.

    2016-01-01

    Electronic components must be tested to ensure reliable performance in high radiation environments such as Hi-Limu LHC and space. We propose a defocusing beam line to perform proton irradiation tests in Turkey. The Turkish Atomic Energy Authority SANAEM Proton Accelerator Facility was inaugurated in May 2012 for radioisotope production. The facility has also an R&D room for research purposes. The accelerator produces protons with 30 MeV kinetic energy and the beam current is variable between View the MathML source10μA and View the MathML source1.2mA. The beam kinetic energy is suitable for irradiation tests, however the beam current is high and therefore the flux must be lowered. We plan to build a defocusing beam line (DBL) in order to enlarge the beam size, reduce the flux to match the required specifications for the irradiation tests. Current design includes the beam transport and the final focusing magnets to blow up the beam. Scattering foils and a collimator is placed for the reduction of the beam ...

  11. A proton irradiation test facility for space research in Ankara, Turkey

    Science.gov (United States)

    Gencer, Ayşenur; Yiǧitoǧlu, Merve; Bilge Demirköz, Melahat; Efthymiopoulos, Ilias

    2016-07-01

    Space radiation often affects the electronic components' performance during the mission duration. In order to ensure reliable performance, the components must be tested to at least the expected dose that will be received in space, before the mission. Accelerator facilities are widely used for such irradiation tests around the world. Turkish Atomic Energy Authority (TAEA) has a 15MeV to 30MeV variable proton cyclotron in Ankara and the facility's main purpose is to produce radioisotopes in three different rooms for different target systems. There is also an R&D room which can be used for research purposes. This paper will detail the design and current state of the construction of a beamline to perform Single Event Effect (SEE) tests in Ankara for the first time. ESA ESCC No.25100 Standard Single Event Effect Test Method and Guidelines is being considered for these SEE tests. The proton beam kinetic energy must be between 20MeV and 200MeV according to the standard. While the proton energy is suitable for SEE tests, the beam size must be 15.40cm x 21.55cm and the flux must be between 10 ^{5} p/cm ^{2}/s to at least 10 ^{8} p/cm ^{2}/s according to the standard. The beam size at the entrance of the R&D room is mm-sized and the current is variable between 10μA and 1.2mA. Therefore, a defocusing beam line has been designed to enlarge the beam size and reduce the flux value. The beam line has quadrupole magnets to enlarge the beam size and the collimators and scattering foils are used for flux reduction. This facility will provide proton fluxes between 10 ^{7} p/cm ^{2}/s and 10 ^{10} p/cm ^{2}/s for the area defined in the standard when completed. Also for testing solar cells developed for space, the proton beam energy will be lowered below 10MeV. This project has been funded by Ministry of Development in Turkey and the beam line construction will finish in two years and SEE tests will be performed for the first time in Turkey.

  12. Post irradiation test report of irradiated DUPIC simulated fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Jung, I. H.; Moon, J. S. and others

    2001-12-01

    The post-irradiation examination of irradiated DUPIC (Direct Use of Spent PWR Fuel in CANDU Reactors) simulated fuel in HANARO was performed at IMEF (Irradiated Material Examination Facility) in KAERI during 6 months from October 1999 to March 2000. The objectives of this post-irradiation test are i) the integrity of the capsule to be used for DUPIC fuel, ii) ensuring the irradiation requirements of DUPIC fuel at HANARO, iii) performance verification in-core behavior at HANARO of DUPIC simulated fuel, iv) establishing and improvement the data base for DUPIC fuel performance verification codes, and v) establishing the irradiation procedure in HANARO for DUPIC fuel. The post-irradiation examination performed are γ-scanning, profilometry, density, hardness, observation the microstructure and fission product distribution by optical microscope and electron probe microanalyser (EPMA)

  13. Fast-neutron dosimetry in the seed-irradiation facility, ASTRA reactor, Seibersdorf

    International Nuclear Information System (INIS)

    Ahnstroem, G.; Burtscher, A.; Casta, J.

    1967-01-01

    An important part of the co-ordinated programme on the neutron irradiation of seeds has been the construction of a fast-neutron irradiation facility for swimming-pool reactors. This facility was installed around 70 cm from the core in the ASTRA reactor swimming-pool at the end of December, 1966. Also, for this programme a pair of constant potential ionization chambers have been constructed at the Institute of Biochemistry, Stockholm University. These chambes are of the type described in the technical annex and are the same size as the seed-irradiation vials to be used in the seed-irradiation container (diam. =15 mm, length = 60 mm). Some preliminary dosimetry experiments were undertaken to test the irradiation facility and the ionization chambers, and to investigate the usefulness of the dosimetry instructions in the Technical Annex. The results of these experiments are discussed in this paper. 3 refs, 6 figs, 7 tabs

  14. Advanced Test Reactor National Scientific User Facility Partnerships

    International Nuclear Information System (INIS)

    Marshall, Frances M.; Allen, Todd R.; Benson, Jeff B.; Cole, James I.; Thelen, Mary Catherine

    2012-01-01

    In 2007, the United States Department of Energy designated the Advanced Test Reactor (ATR), located at Idaho National Laboratory, as a National Scientific User Facility (NSUF). This designation made test space within the ATR and post-irradiation examination (PIE) equipment at INL available for use by researchers via a proposal and peer review process. The goal of the ATR NSUF is to provide researchers with the best ideas access to the most advanced test capability, regardless of the proposer's physical location. Since 2007, the ATR NSUF has expanded its available reactor test space, and obtained access to additional PIE equipment. Recognizing that INL may not have all the desired PIE equipment, or that some equipment may become oversubscribed, the ATR NSUF established a Partnership Program. This program enables and facilitates user access to several university and national laboratories. So far, seven universities and one national laboratory have been added to the ATR NSUF with capability that includes reactor-testing space, PIE equipment, and ion beam irradiation facilities. With the addition of these universities, irradiation can occur in multiple reactors and post-irradiation exams can be performed at multiple universities. In each case, the choice of facilities is based on the user's technical needs. Universities and laboratories included in the ATR NSUF partnership program are as follows: (1) Nuclear Services Laboratories at North Carolina State University; (2) PULSTAR Reactor Facility at North Carolina State University; (3) Michigan Ion Beam Laboratory (1.7 MV Tandetron accelerator) at the University of Michigan; (4) Irradiated Materials at the University of Michigan; (5) Harry Reid Center Radiochemistry Laboratories at University of Nevada, Las Vegas; (6) Characterization Laboratory for Irradiated Materials at the University of Wisconsin-Madison; (7) Tandem Accelerator Ion Beam. (1.7 MV terminal voltage tandem ion accelerator) at the University of Wisconsin

  15. Neutronics analysis of International Fusion Material Irradiation Facility (IFMIF). Japanese contributions

    International Nuclear Information System (INIS)

    Oyama, Yukio; Noda, Kenji; Kosako, Kazuaki.

    1997-10-01

    In fusion reactor development for demonstration reactor, i.e., DEMO, materials tolerable for D-T neutron irradiation are absolutely required for both mechanical and safety point of views. For this requirement, several kinds of low activation materials were proposed. However, experimental data by actual D-T fusion neutron irradiation have not existed so far because of lack of fusion neutron irradiation facility, except fundamental radiation damage studies at very low neutron fluence. Therefore such a facility has been strongly requested. According to agreement of need for such a facility among the international parties, a conceptual design activity (CDA) of International Fusion Material Irradiation Facility (IFMIF) has been carried out under the frame work of the IEA-Implementing Agreement. In the activity, a neutronics analysis on irradiation field optimization in the IFMIF test cell was performed in three parties, Japan, US and EU. As the Japanese contribution, the present paper describes a neutron source term as well as incident deuteron beam angle optimization of two beam geometry, beam shape (foot print) optimization, and dpa, gas production and heating estimation inside various material loading Module, including a sensitivity analysis of source term uncertainty to the estimated irradiation parameters. (author)

  16. Reconstruction of Co-60 Irradiation Facility No.1

    International Nuclear Information System (INIS)

    Nakamura, Yoshiteru; Takada, Isao; Kaneko, Hirohisa; Hirao, Toshio; Haneda, Noriyuki; Mitomo, Shouichi; Tachibana, Hiroyuki; Yoshida, Kenzou

    1989-01-01

    Cobalt Irradiation Facility No.1 was constructed in 1964 as the first large scale Co-60 irradiation facility equipped a deep water pool for source storage of Co-60 sources. Recently, the reconstruction of the facility was decided because the aging of various parts of the facility became remarkable and new research programs required upgradings of the facility. Important points of upgradings are as follows: A shielding capacity of the source storage and pool is increased to 55.5 PBq from 18.5 PBq. The opening in a floor of the irradiation room which is used for the source lifting in the room, is enlarged in order to utilize a large and high intensity source. Radiation resistance of the irradiation apparatus and installed equipments in the radiation room is increased for a high dose rate irradiation. Basic structure and shape of the facility building such as shielding, pool and building roof is not changed but electrical, mechanical equipments and systems are completely renewed. To increase a reliability, the irradiation apparatus and systems are also replaced with an improved and up-to-date one designed based on operation experiences of Co-60 facilities at TRCRE through many years. In addition, auxiliary equipments such as radiation monitors, manipulators, water treatment system and so on are replaced. This report presents the reconstruction of Co-60 Irradiation Facility No.1 stressing on the replacement and modification of the irradiation apparatus. (author)

  17. Construction of irradiated material examination facility-basic design

    International Nuclear Information System (INIS)

    Ro, Seung Gy; Kim, Eun Ka; Hong, Gye Won; Herr, Young Hoi; Hong, Kwon Pyo; Lee, Myeong Han; Baik, Sang Youl; Choo, Yong Sun; Baik, Seung Je

    1989-02-01

    The basic design of the hot cell facility which has the main purpose of doing mechanical and physical property tests of irradiated materials, the examination process, and the annexed facility has been made. Also basic and detall designs for the underground excavation work have been performed. The project management and tasks required for the license application have been carried out in due course. The facility is expected to be completed by the end of 1992, if the budgetary support is sufficient. (Author)

  18. DeBeNe Test Facilities for Fast Breeder Development

    International Nuclear Information System (INIS)

    Storz, R.

    1980-10-01

    This report gives an overview and a short description of the test facilities constructed and operated within the collaboration for fast breeder development in Germany, Belgium and the Netherlands. The facilities are grouped into Sodium Loops (Large Facilities and Laboratory Loops), Special Equipment including Hot Cells and Reprocessing, Test Facilities without Sodium, Zero Power Facilities and In-pile Loops including Irradiation Facilities

  19. Mechanical Design and Manufacturing Preparation of Loading Unloading Irradiation Facility in Reflector Irradiation Position

    International Nuclear Information System (INIS)

    Hasibuan, Djaruddin

    2004-01-01

    Base on planning to increase of the irradiation service quality in Multi purpose Reactor-GAS, the mechanical design and manufacturing of the (n,γ) irradiation facility has been done. The designed of (n,γ) irradiation facility is a new facility in Multi purpose Reactor-GAS. The design doing by design of stringer, guide bar and hanger. By the design installation, the continuous irradiation service of non fission reaction will be easy to be done without reactor shut down. The design of the facility needs 3 pieces Al pipe by 36 x 1.5 mm, a peace of Al round bar by 80 mm diameter and a piece of Al plate by 20 x 60 x 0.2 mm for the stringer and guide bar manufacturing. By the building of non fission irradiation facility in the reflector irradiation position, will make the irradiation service to be increased. (author)

  20. The WR-1 corrosion test facility

    International Nuclear Information System (INIS)

    Murphy, E.V.; Simmons, G.R.

    1978-07-01

    This report describes a new Corrosion Test Facility which has recently been installed in the WR-1 organic-cooled research reactor. The irradiation facility is a single insert, installed in a reactor site, which can deliver a fast neutron flux density of 2.65 x 10 17 neutrons/(m 2 .s) to specimens under irradiation. A self-contained controlled-chemistry cooling water circuit removes the gamma- and neutron-heat generated in the insert and specimens. Specimen temperatures typically vary from 245 deg C to 280 deg C across the insert core region. (author)

  1. HRB-22 irradiation phase test data report

    International Nuclear Information System (INIS)

    Montgomery, F.C.; Acharya, R.T.; Baldwin, C.A.; Rittenhouse, P.L.; Thoms, K.R.; Wallace, R.L.

    1995-03-01

    Irradiation capsule HRB-22 was a test capsule containing advanced Japanese fuel for the High Temperature Test Reactor (HTTR). Its function was to obtain fuel performance data at HTTR operating temperatures in an accelerated irradiation environment. The irradiation was performed in the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL). The capsule was irradiated for 88.8 effective full power days in position RB-3B of the removable beryllium (RB) facility. The maximum fuel compact temperature was maintained at or below the allowable limit of 1300 degrees C for a majority of the irradiation. This report presents the data collected during the irradiation test. Included are test thermocouple and gas flow data, the calculated maximum and volume average temperatures based on the measured graphite temperatures, measured gaseous fission product activity in the purge gas, and associated release rate-to-birth rate (R/B) results. Also included are quality assurance data obtained during the test

  2. Design, fabrication and installation of irradiation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Bong Shick; Kim, Y. S.; Lee, C. Y. and others

    1999-03-01

    The principal contents of this project are to design, fabricate and install the steady-state fuel test loop in HANARO for nuclear technology development. Procurement and fabrication of main equipment, licensing and technical review for fuel test loop have been performed during 2 years(1997, 1998) for this project. Following contents are described in the report. - Procurement and fabrication of the equipment, piping for OPS - IPS manufacture - License - Technical review and evaluation of the FTL facility. As besides, as these irradiation facilities will be installed in HANARO, review of safety concern, discussion with KINS for licensing and review ofHANARO interface have been performed respectively. (author)

  3. How to improve the irradiation conditions for the International Fusion Materials Irradiation Facility

    CERN Document Server

    Daum, E

    2000-01-01

    The accelerator-based intense D-Li neutron source International Fusion Materials Irradiation Facility (IFMIF) provides very suitable irradiation conditions for fusion materials development with the attractive option of accelerated irradiations. Investigations show that a neutron moderator made of tungsten and placed in the IFMIF test cell can further improve the irradiation conditions. The moderator softens the IFMIF neutron spectrum by enhancing the fraction of low energy neutrons. For displacement damage, the ratio of point defects to cascades is more DEMO relevant and for tritium production in Li-based breeding ceramic materials it leads to a preferred production via the sup 6 Li(n,t) sup 4 He channel as it occurs in a DEMO breeding blanket.

  4. Current status of irradiation facilities in JRR-3 and JRR-4

    International Nuclear Information System (INIS)

    Hori, Naohiko; Wada, Shigeru; Sasajima, Fumio; Kusunoki, Tsuyoshi

    2006-01-01

    The Department of Research Reactor has operated two research reactors, JRR-3 and JRR-4. These reactors were constructed in the Tokai Research Establishment. Many researchers and engineers use these joint-use facilities. JRR-3 is a light water moderated and cooled, pool type research reactor using low-enriched silicide fuel. JRR-3's maximum thermal power is 20MW. JRR-3 has nine vertical irradiation holes for RI production, nuclear fuels and materials irradiation at reactor core area. JRR-3 has many kinds of irradiation holes in a heavy water tank around the reactor core. These are two hydraulic rabbit irradiation facilities, two pneumatic rabbit irradiation facilities, one activation analysis irradiation facilities, one uniform irradiation facility, one rotating irradiation facility and one capsule irradiation facility. JRR-3 has nine horizontal experimental holes, that are used by many kinds of neutron beam experimental facilities using these holes. JRR-4 is a light water moderated and cooled, swimming pool type research reactor using low-enriched silicide fuel. JRR-4's maximum thermal power is 3.5MW. JRR-4 has five vertical irradiation tubes at reactor core area, three capsule irradiation facilities, one hydraulic rabbit irradiation facility, and one pneumatic rabbit irradiation facility. JRR-4 has a neutron beam hole, and it has used neutron beam experiments, irradiations for activation analysis and medical neutron irradiations. (author)

  5. Near term, low cost, 14 MeV fusion neutron irradiation facility for testing the viability of fusion structural materials

    Energy Technology Data Exchange (ETDEWEB)

    Kulcinski, Gerald L., E-mail: glkulcin@wisc.edu [University of Wisconsin-Madison, Madison, WI (United States); Radel, Ross F. [Phoenix Nuclear Labs LLC, Monona, WI (United States); Davis, Andrew [University of Wisconsin-Madison, Madison, WI (United States)

    2016-11-01

    For over 50 years, engineers have been looking for an irradiation facility that can provide a fusion reactor appropriate neutron spectrum over a significant volume to test fusion reactor materials that is relatively inexpensive and can be built in a minimum of time. The 14 MeV neutron irradiation facility described here can nearly exactly duplicate the neutron spectrum typical of a DT fusion reactor first wall at damage rates of ≈4 displacements per atom and 40 appm He generated over a 2 l volume per full power year of operation. The projected cost of this multi-beam facility is estimated at ≈$20 million and it can be built in <4 years. A single-beam prototype, funded by the U.S. Department of Energy, is already being built to produce medical isotopes. The neutrons are produced by a 300 keV deuterium beam accelerated into 4 kPa (30 Torr) tritium target. The total tritium inventory is <2 g and <0.1 g of T{sub 2} is consumed per year. The core technology proposed has already been fully demonstrated, and no new plasma physics or materials innovations will be required for the test facility to become operational.

  6. Irradiation Facilities at the Advanced Test Reactor

    International Nuclear Information System (INIS)

    S. Blaine Grover

    2005-01-01

    The Advanced Test Reactor (ATR) is the third generation and largest test reactor built in the Reactor Technology Complex (RTC) (formerly known as the Test Reactor Area), located at the Idaho National Laboratory (INL), to study the effects of intense neutron and gamma radiation on reactor materials and fuels. The RTC was established in the early 1950s with the development of the Materials Testing Reactor (MTR), which operated until 1970. The second major reactor was the Engineering Test Reactor (ETR), which operated from 1957 to 1981, and finally the ATR, which began operation in 1967 and will continue operation well into the future. These reactors have produced a significant portion of the world's data on materials response to reactor environments. The wide range of experiment facilities in the ATR and the unique ability to vary the neutron flux in different areas of the core allow numerous experiment conditions to co-exist during the same reactor operating cycle. Simple experiments may involve a non-instrumented capsule containing test specimens with no real-time monitoring or control capabilities. More sophisticated testing facilities include inert gas temperature control systems and pressurized water loops that have continuous chemistry, pressure, temperature, and flow control as well as numerous test specimen monitoring capabilities. There are also apparatus that allow for the simulation of reactor transients on test specimens

  7. Monte Carlo simulations and dosimetric studies of an irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Belchior, A. [Instituto Tecnologico e Nuclear, Estrada nacional no. 10, Apartado 21, 2686-953 Sacavem (Portugal)], E-mail: anabelchior@itn.pt; Botelho, M.L; Vaz, P. [Instituto Tecnologico e Nuclear, Estrada nacional no. 10, Apartado 21, 2686-953 Sacavem (Portugal)

    2007-09-21

    There is an increasing utilization of ionizing radiation for industrial applications. Additionally, the radiation technology offers a variety of advantages in areas, such as sterilization and food preservation. For these applications, dosimetric tests are of crucial importance in order to assess the dose distribution throughout the sample being irradiated. The use of Monte Carlo methods and computational tools in support of the assessment of the dose distributions in irradiation facilities can prove to be economically effective, representing savings in the utilization of dosemeters, among other benefits. One of the purposes of this study is the development of a Monte Carlo simulation, using a state-of-the-art computational tool-MCNPX-in order to determine the dose distribution inside an irradiation facility of Cobalt 60. This irradiation facility is currently in operation at the ITN campus and will feature an automation and robotics component, which will allow its remote utilization by an external user, under REEQ/996/BIO/2005 project. The detailed geometrical description of the irradiation facility has been implemented in MCNPX, which features an accurate and full simulation of the electron-photon processes involved. The validation of the simulation results obtained was performed by chemical dosimetry methods, namely a Fricke solution. The Fricke dosimeter is a standard dosimeter and is widely used in radiation processing for calibration purposes.

  8. Final report of the HFIR [High Flux Isotope Reactor] irradiation facilities improvement project

    International Nuclear Information System (INIS)

    Montgomery, B.H.; Thoms, K.R.; West, C.D.

    1987-09-01

    The High-Flux Isotope Reactor (HFIR) has outstanding neutronics characteristics for materials irradiation, but some relatively minor aspects of its mechanical design severely limited its usefulness for that purpose. In particular, though the flux trap region in the center of the annular fuel elements has a very high neutron flux, it had no provision for instrumentation access to irradiation capsules. The irradiation positions in the beryllium reflector outside the fuel elements also have a high flux; however, although instrumented, they were too small and too few to replace the facilities of a materials testing reactor. To address these drawbacks, the HFIR Irradiation Facilities Improvement Project consisted of modifications to the reactor vessel cover, internal structures, and reflector. Two instrumented facilities were provided in the flux trap region, and the number of materials irradiation positions in the removable beryllium (RB) was increased from four to eight, each with almost twice the available experimental space of the previous ones. The instrumented target facilities were completed in August 1986, and the RB facilities were completed in June 1987

  9. A flexible testing facility for high-power targets T-MIF

    International Nuclear Information System (INIS)

    Fusco, Y.; Samec, K.; Behzad, M.; Kadi, Y.

    2015-01-01

    A dedicated material test irradiation facility is being proposed. The testing station will allow critical issues concerning materials under irradiation to be addressed, such as the impact of proton beam irradiation, neutron irradiation, liquid metal corrosion and temperature. The material samples to be investigated in such a facility will be subjected to tensile stress, either constant or cyclical. The facility may also be used for sensor development under irradiation and isotope production. The goal of the current work is to propose a facility that is sufficiently versatile and compact so that it may be transported and used in different laboratories. The power is limited to 100 kW. The general aspect of the proposed irradiation facility is a cube, 2 metres deep and comprising within it all the necessary systems. The interface to the laboratory is limited to the coolant connections, the secondary circuit, the electric energy supply and the signals from the instrumentation. The liquid metal target placed in the centre of the facility contains the samples which are subjected to a proton beam, creating irradiation damage directly through protons or indirectly through neutrons created by spallation of the surrounding liquid metal by the incoming protons. The design of the target is based upon the EURISOL target. The same beam window design is used, albeit stretched horizontally to adopt an elliptical section which is compatible with the shape of the beam used to irradiate the samples. The liquid metal in the target is re-circulated by an electromagnetic pump that drives the liquid metal through a heat exchanger located at the top of the facility, the position of which was chosen to encourage natural circulation. The heat exchanger is made up of two separate parts which allow the primary and secondary circuit to separate cleanly

  10. Overview of the IFMIF test facility design in IFMIF/EVEDA phase

    International Nuclear Information System (INIS)

    Tian, Kuo; Abou-Sena, Ali; Arbeiter, Frederik; García, Ángela; Gouat, Philippe; Heidinger, Roland; Heinzel, Volker; Ibarra, Ángel; Leysen, Willem; Mas, Avelino; Mittwollen, Martin; Möslang, Anton; Theile, Jürgen; Yamamoto, Michiyoshi; Yokomine, Takehiko

    2015-01-01

    Highlights: • This paper summarizes the current design status of IFMIF EVEDA test facility. • The principle functions of the test facility and key components are described. • The brief specifications of the systems and key components are addressed. - Abstract: The test facility (TF) is one of the three major facilities of the International Fusion Material Irradiation Facility (IFMIF). Engineering designs of TF main systems and key components have been initiated and developed in the IFMIF EVEDA (Engineering Validation and Engineering Design Activities) phase since 2007. The related work covers the designs of a test cell which is the meeting point of the TF and accelerator facility and lithium facility, a series of test modules for experiments under different irradiation conditions, an access cell to accommodate remote handling systems, four test module handling cells for test module processing and assembling, and test facility ancillary systems for engineering support on energy, media, and control infrastructure. This paper summarizes the principle functions, brief specifications, and the current design status of the above mentioned IFMIF TF systems and key components.

  11. Probabilistic safety assessment for food irradiation facility

    International Nuclear Information System (INIS)

    Solanki, R.B.; Prasad, M.; Sonawane, A.U.; Gupta, S.K.

    2012-01-01

    Highlights: ► Different considerations are required in PSA for Non-Reactor Nuclear Facilities. ► We carried out PSA for food irradiation facility as a part of safety evaluation. ► The results indicate that the fatal exposure risk is below the ‘acceptable risk’. ► Adequate operator training and observing good safety culture would reduce the risk. - Abstract: Probabilistic safety assessment (PSA) is widely used for safety evaluation of Nuclear Power Plants (NPPs) worldwide. The approaches and methodologies are matured and general consensus exists on using these approaches in PSA applications. However, PSA applications for safety evaluation for non-reactor facilities are limited. Due to differences in the processes in nuclear reactor facilities and non-reactor facilities, the considerations are different in application of PSA to these facilities. The food irradiation facilities utilize gamma irradiation sources, X-ray machines and electron accelerators for the purpose of radiation processing of variety of food items. This is categorized as Non-Reactor Nuclear Facility. In this paper, the application of PSA to safety evaluation of food irradiation facility is presented considering the ‘fatality due to radiation overexposure’ as a risk measure. The results indicate that the frequency of the fatal exposure is below the numerical acceptance guidance for the risk to the individual. Further, it is found that the overall risk to the over exposure can be reduced by providing the adequate operator training and observing good safety culture.

  12. CERN IRRADIATION FACILITIES.

    Science.gov (United States)

    Pozzi, Fabio; Garcia Alia, Ruben; Brugger, Markus; Carbonez, Pierre; Danzeca, Salvatore; Gkotse, Blerina; Richard Jaekel, Martin; Ravotti, Federico; Silari, Marco; Tali, Maris

    2017-09-28

    CERN provides unique irradiation facilities for applications in dosimetry, metrology, intercomparison of radiation protection devices, benchmark of Monte Carlo codes and radiation damage studies to electronics. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. A new materials irradiation facility at the Kyoto university reactor

    International Nuclear Information System (INIS)

    Yoshiie, T.; Hayashi, Y.; Yanagita, S.; Xu, Q.; Satoh, Y.; Tsujimoto, H.; Kozuka, T.; Kamae, K.; Mishima, K.; Shiroya, S.; Kobayashi, K.; Utsuro, M.; Fujita, Y.

    2003-01-01

    A new materials irradiation facility with improved control capabilities has been installed at the Kyoto University Reactor (KUR). Several deficiencies of conventional fission neutron material irradiation systems have been corrected. The specimen temperature is controlled both by an electric heater and by the helium pressure in the irradiation tube without exposure to neutrons at temperatures different from the design test conditions. The neutron spectrum is varied by the irradiation position. Irradiation dose is changed by pulling the irradiation capsule up and down during irradiation. Several characteristics of the irradiation field were measured. The typical irradiation intensity is 9.4x10 12 n/cm 2 s (>0.1 MeV) and the irradiation temperature of specimens is controllable from 363 to 773 K with a precision of ±2 K

  14. A standard fission neutron irradiation facility

    International Nuclear Information System (INIS)

    Sahasrabudhe, S.G.; Chakraborty, P.P.; Iyer, M.R.; Kirthi, K.N.; Soman, S.D.

    1979-01-01

    A fission neutron irradiation facility (FISNIF) has been set up at the thermal column of the CIRUS reactor at BARC. The spectrum and the flux have been measured using threshold detectors. The paper describes the setting up of the facility, measurement and application. A concentric cylinder containing UO 2 powder sealed inside surrounds the irradiation point of a pneumatic sample transfer system located in the thermal column of the reactor. Samples are loaded in a standard aluminium capsule with cadmium lining and transported pneumatically. A sample transfer time of 1 s can be achieved in the facility. Typical applications of the facility for studying activation of iron and sodium in fission neutrons are also discussed. (Auth.)

  15. Design, fabrication and installation of irradiation facilities

    International Nuclear Information System (INIS)

    Kim, Yong Sung; Lee, C. Y.; Kim, J. Y.; Chi, D. Y.; Kim, S. H.; Ahn, S. H.; Kim, S. J.; Kim, J. K.; Yang, S. H.; Yang, S. Y.; Kim, H. R.; Kim, H.; Lee, K. H.; Lee, B. C.; Park, C.; Lee, C. T.; Cho, S. W.; Kwak, K. K.; Suk, H. C.

    1997-07-01

    The principle contents of this project are to design, fabricate and install the steady-state fuel test loop and non-instrumented capsule in HANARO for nuclear technology development. This project will be completed in 1999, the basic and detail design, safety analysis, and procurement of main equipment for fuel test loop have been performed and also the piping in gallery and the support for IPS piping in reactor pool have been installed in 1994. In the area of non-instrumented capsule for material irradiation test, the fabrication of capsule has been completed. Procurement, fabrication and installation of the fuel test loop will be implemented continuously till 1999. As besides, as these irradiation facilities will be installed in HANARO, review of safety concern, discussion with KINS for licensing and safety analysis report has been submitted to KINS to get a license and review of HANARO interface have been performed respectively. (author). 39 refs., 28 tabs., 21 figs

  16. Design, fabrication and installation of irradiation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sung; Lee, C. Y.; Kim, J. Y.; Chi, D. Y.; Kim, S. H.; Ahn, S. H.; Kim, S. J.; Kim, J. K.; Yang, S. H.; Yang, S. Y.; Kim, H. R.; Kim, H.; Lee, K. H.; Lee, B. C.; Park, C.; Lee, C. T.; Cho, S. W.; Kwak, K. K.; Suk, H. C. [and others

    1997-07-01

    The principle contents of this project are to design, fabricate and install the steady-state fuel test loop and non-instrumented capsule in HANARO for nuclear technology development. This project will be completed in 1999, the basic and detail design, safety analysis, and procurement of main equipment for fuel test loop have been performed and also the piping in gallery and the support for IPS piping in reactor pool have been installed in 1994. In the area of non-instrumented capsule for material irradiation test, the fabrication of capsule has been completed. Procurement, fabrication and installation of the fuel test loop will be implemented continuously till 1999. As besides, as these irradiation facilities will be installed in HANARO, review of safety concern, discussion with KINS for licensing and safety analysis report has been submitted to KINS to get a license and review of HANARO interface have been performed respectively. (author). 39 refs., 28 tabs., 21 figs.

  17. Food irradiation: Gamma processing facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kunstadt, P. [MDS Nordion International, 447 March Road. Kanata, Ontario, K2K148 (Canada)

    1997-12-31

    The number of products being radiation processed is constantly increasing and today include such diverse items as medical disposable, fruits and vegetables, bulk spices, meats, sea foods and waste effluents. Not only do the products differ but also many products, even those within the same groupings, require different minimum and maximum radiation doses. These variations create many different requirements in the irradiator design. The design of Cobalt-60 radiation processing facilities is well established for a number of commercial applications. Installations in over 40 countries, with some in operation since the early 1960s, are testimony to the fact that irradiator design, manufacture, installation and operation is a well established technology. However, in order to design gamma irradiators for the preservation of foods one must recognize those parameters typical to the food irradiation process as well as those systems and methods already well established in the food industry. This paper discusses the basic design concepts for gamma food irradiators. They are most efficient when designed to handle a limited product density range at an established dose. Safety of Cobalt-60 transport, safe facility operation principles and the effect of various processing parameters on economics, will also be discussed. (Author)

  18. Food irradiation: Gamma processing facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kunstadt, P [MDS Nordion International, 447 March Road. Kanata, Ontario, K2K148 (Canada)

    1998-12-31

    The number of products being radiation processed is constantly increasing and today include such diverse items as medical disposable, fruits and vegetables, bulk spices, meats, sea foods and waste effluents. Not only do the products differ but also many products, even those within the same groupings, require different minimum and maximum radiation doses. These variations create many different requirements in the irradiator design. The design of Cobalt-60 radiation processing facilities is well established for a number of commercial applications. Installations in over 40 countries, with some in operation since the early 1960s, are testimony to the fact that irradiator design, manufacture, installation and operation is a well established technology. However, in order to design gamma irradiators for the preservation of foods one must recognize those parameters typical to the food irradiation process as well as those systems and methods already well established in the food industry. This paper discusses the basic design concepts for gamma food irradiators. They are most efficient when designed to handle a limited product density range at an established dose. Safety of Cobalt-60 transport, safe facility operation principles and the effect of various processing parameters on economics, will also be discussed. (Author)

  19. Food irradiation: Gamma processing facilities

    International Nuclear Information System (INIS)

    Kunstadt, P.

    1997-01-01

    The number of products being radiation processed is constantly increasing and today include such diverse items as medical disposable, fruits and vegetables, bulk spices, meats, sea foods and waste effluents. Not only do the products differ but also many products, even those within the same groupings, require different minimum and maximum radiation doses. These variations create many different requirements in the irradiator design. The design of Cobalt-60 radiation processing facilities is well established for a number of commercial applications. Installations in over 40 countries, with some in operation since the early 1960s, are testimony to the fact that irradiator design, manufacture, installation and operation is a well established technology. However, in order to design gamma irradiators for the preservation of foods one must recognize those parameters typical to the food irradiation process as well as those systems and methods already well established in the food industry. This paper discusses the basic design concepts for gamma food irradiators. They are most efficient when designed to handle a limited product density range at an established dose. Safety of Cobalt-60 transport, safe facility operation principles and the effect of various processing parameters on economics, will also be discussed. (Author)

  20. Startup of the Whiteshell irradiation facility

    International Nuclear Information System (INIS)

    Barnard, J.W.; Stanley, F.W.

    1989-01-01

    Recently, a 10-MeV, 1-kW electron linear accelerator was installed in a specially designed irradiation facility at the Whiteshell Nuclear Research Establishment. The facility was designed for radiation applications research in the development of new radiation processes up to the pilot scale level. The accelerator is of advanced design. Automatic startup via computer control makes it compatible with industrial processing. It has been operated successfully as a fully integrated electron irradiator for a number of applications including curing of plastics and composites, sterilization of medical disposables and animal feed irradiation. We report here on our experience during the first six months of operation. (orig.)

  1. Startup of the whiteshell irradiation facility

    Science.gov (United States)

    Barnard, J. W.; Stanley, F. W.

    1989-04-01

    Recently, a 10-MeV, 1-kW electron linear accelerator was installed in a specially designed irradiation facility at the Whiteshell Nuclear Research Establishment. The facility was designed for radiation applications research in the development of new radiation processes up to the pilot scale level. The accelerator is of advanced design. Automatic startup via computer control makes it compatible with industrial processing. It has been operated successfully as a fully integrated electron irradiator for a number of applications including curing of plastics and composites, sterilization of medical disposables and animal feed irradiation. We report here on our experience during the first six months of operation.

  2. Towards a Unified Environmental Monitoring, Control and Data Management System for Irradiation Facilities: the CERN IRRAD Use Case

    CERN Document Server

    Gkotse, Blerina; Jouvelot, Pierre; Matli, Emanuele; Pezzullo, Giuseppe; Ravotti, Federico

    2017-01-01

    The qualification of materials, electronic components and equipment for the CERN High Energy Physics experiments and beyond requires testing against possible radiation effects. These quite complex tests are performed by specialized teams working in irradiation facilities such as IRRAD, the Proton Irradiation Facility at CERN. Building upon the details of the overall irradiation control, monitoring, and logistical systems of IRRAD as a use case, we introduce the motivations for and general architecture of its new data management framework, currently under development at CERN. This infrastructure is intended to allow for the seamless and comprehensive handling of IRRAD irradiation experiments and to help manage all aspects of the facility. Its architecture, currently focused on the specific requirements of the IRRAD facility, is intended to be upgraded to a general framework that could be used in other irradiation facilities within the radiation effects community, as well as for other applications.

  3. National Low-Temperature Neutron Irradiation Facility (NLTNIF). The status of development

    International Nuclear Information System (INIS)

    Coltman, R.R. Jr.; Kerchner, H.R.; Klabunde, C.E.; Young, F.W. Jr.

    1985-12-01

    In May 1983, the Department of Energy authorized the establishment of a National Low-Temperature Neutron Irradiation Facility (NLTNIF) at ORNL's Bulk Shielding Reactor (BSR). The NLTNIF, which will be available for qualified experiments at no cost to users, will provide a combination of high radiation intensities and special environmental and testing conditions that have not been previously available in the US. Since the DOE authorization, work has proceeded on the design and construction of the new facility without interruption. This report describes the present status of the development of the NLTNIF and the anticipated schedule for completion and performance testing. There is a table of the major specifications and capabilities and a schematic layout of the irradiation cryostate for design and dimensioning of test and experiment assemblies

  4. The Advanced Test Reactor National Scientific User Facility Advancing Nuclear Technology

    International Nuclear Information System (INIS)

    Allen, T.R.; Benson, J.B.; Foster, J.A.; Marshall, F.M.; Meyer, M.K.; Thelen, M.C.

    2009-01-01

    To help ensure the long-term viability of nuclear energy through a robust and sustained research and development effort, the U.S. Department of Energy (DOE) designated the Advanced Test Reactor and associated post-irradiation examination facilities a National Scientific User Facility (ATR NSUF), allowing broader access to nuclear energy researchers. The mission of the ATR NSUF is to provide access to world-class nuclear research facilities, thereby facilitating the advancement of nuclear science and technology. The ATR NSUF seeks to create an engaged academic and industrial user community that routinely conducts reactor-based research. Cost free access to the ATR and PIE facilities is granted based on technical merit to U.S. university-led experiment teams conducting non-proprietary research. Proposals are selected via independent technical peer review and relevance to DOE mission. Extensive publication of research results is expected as a condition for access. During FY 2008, the first full year of ATR NSUF operation, five university-led experiments were awarded access to the ATR and associated post-irradiation examination facilities. The ATR NSUF has awarded four new experiments in early FY 2009, and anticipates awarding additional experiments in the fall of 2009 as the results of the second 2009 proposal call. As the ATR NSUF program mature over the next two years, the capability to perform irradiation research of increasing complexity will become available. These capabilities include instrumented irradiation experiments and post-irradiation examinations on materials previously irradiated in U.S. reactor material test programs. The ATR critical facility will also be made available to researchers. An important component of the ATR NSUF an education program focused on the reactor-based tools available for resolving nuclear science and technology issues. The ATR NSUF provides education programs including a summer short course, internships, faculty-student team

  5. The construction of irradiated material examination facility

    International Nuclear Information System (INIS)

    Ro, Seung Gy; Lee, Key Soon; Herr, Young Hoi

    1990-03-01

    A detail design of the examination process, the hot cell facility and the annexed facility of the irradiated material examination facility (IMEF) which will be utilized to examine and evaluate physical and mechanical properties of neutron-irradiated materials, has been performed. Also a start-up work of the underground structure construction has been launched out. The project management and tasks required for the license application were duly carried out. The resultant detail design data will be used for the next step. (author)

  6. AECL hot-cell facilities and post-irradiation examination services

    International Nuclear Information System (INIS)

    Schankula, M.H.; Plaice, E.L.; Woodworth, L.G.

    1998-04-01

    This paper presents an overview of the post-irradiation examination (PIE) services available at AECL's hot-cell facilities (HCF). The HCFs are used primarily to provide PIE support for operating CANDU power reactors in Canada and abroad, and for the examination of experimental fuel bundles and core components irradiated in research reactors at the Chalk River Laboratories (CRL) and off-shore. A variety of examinations and analyses are performed ranging from non-destructive visual and dimensional inspections to detailed optical and scanning electron microscopic examinations. Several hot cells are dedicated to mechanical property testing of structural materials and to determine the fitness-for-service of reactor core components. Facility upgrades and the development of innovative examination techniques continue to improve AECL's PIE capabilities. (author)

  7. AECL hot-cell facilities and post-irradiation examination services

    International Nuclear Information System (INIS)

    Schankula, M.H.; Plaice, E.L.; Woodworth, L.G.

    1995-01-01

    This paper presents an overview of the post-irradiation examination (PIE) services available at AECL's hot-cell facilities (HCF). The HCFs are used primarily to provide PIE support for operating CANDU power reactors in Canada and abroad, and for the examination of experimental fuel bundles and core components irradiated in research reactors at the Chalk River Laboratories (CRL) and off-shore. A variety of examinations and analysis are performed ranging from non-destructive visual and dimensional inspections to detailed optical and scanning electron microscopic examinations. Several hot cells are dedicated to mechanical property testing of structural materials and to determine the fitness-for-service of reactor core components. Facility upgrades and the development of innovative examination techniques continue to improve AECL's PIE capabilities. (author)

  8. Design, Fabrication, and Initial Operation of a Reusable Irradiation Facility

    International Nuclear Information System (INIS)

    Heatherly, D.W.; Thoms, K.R.; Siman-Tov, I.I.; Hurst, M.T.

    1999-01-01

    A Heavy-Section Steel Irradiation (HSSI) Program project, funded by the US Nuclear Regulatory Commission, was initiated at Oak Ridge National Laboratory to develop reusable materials irradiation facilities in which metallurgical specimens of reactor pressure vessel steels could be irradiated. As a consequence, two new, identical, reusable materials irradiation facilities have been designed, fabricated, installed, and are now operating at the Ford Nuclear Reactor at the University of Michigan. The facilities are referred to as the HSSI-IAR facilities with the individual facilities being designated as IAR-1 and IAR-2. This new and unique facility design requires no cutting or grinding operations to retrieve irradiated specimens, all capsule hardware is totally reusable, and materials transported from site to site are limited to specimens only. At the time of this letter report, the facilities have operated successfully for approximately 2500 effective full-power hours

  9. New multipurpose gamma-irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, G

    1985-01-01

    In the past 3 years much work has been done in the G.D.R. on food irradiation. The experiments have shown that this treatment gives favourable results in many products such as spices, onions, potatoes, chicken, animal feeds, fodder yeast, drugs and vaccines. Economic aspects of food irradiation require the effective use of an irradiation plant and cobalt-60. Therefore, a new multipurpose irradiation facility was developed, applicable as an onion irradiator with a capacity of about 15 ton/h and for the simultaneous irradiation of different products (spices, animal feed, chicken, etc.) in closed product boxes with a size of 1.2 m x 1.0 m x 1.2 m. A microcomputer controls the transport of product boxes around the gamma sources.

  10. The operation of post-irradiation examination facility

    International Nuclear Information System (INIS)

    Kim, Eun Ka; Min, Duk Ki; Lee, Young Kil

    1994-12-01

    The operation of post-irradiation examination facility was performed as follow. HVAC and pool water treatment system were continuously operated, and radiation monitoring in PIE facility has been carried out to maintain the facility safely. Inspection of the fuel assembly (F02) transported from Kori Unit 1 was performed in pool, and fuel rods extracted from the fuel assembly (J44) of Kori Unit 2 NPP were examined in hot cell. A part of deteriorated pipe line of drinking water was exchanged for stainless steel pipe to prevent leaking accidents. Halon gas system was also installed in the exhausting blower room for fire fighting. And IAEA inspection camera for safeguard of nuclear materials was fixed at the wall in pool area. Radiation monitoring system were improved to display the area radioactive value at CRT monitor in health physics control room. And automatic check system for battery and emergency diesel generator was developed to measure the voltage and current of them. The performance test of oxide thickness measuring device installed in hot cell for irradiated fuel rod and improvement of the device were performed, and good measuring results using standard sample were obtained. The safeguard inspection of nuclear materials and operation inspection of the facility were carried out through the annual operation inspection, quarterly IAEA inspection and quality assurance auditing. 26 tabs., 43 figs., 14 refs. (Author) .new

  11. Design of special facility for liquor irradiation

    International Nuclear Information System (INIS)

    Yao Shibin; Chen Zigen

    1989-01-01

    The design principle, physical scheme, technological process, construction and safety features of a special facility used for irradiating liquors is briefly described. 0.925 x 10 15 Bq cobalt source is used and the irradiation capacity for liquors approaches 10 t per day. The facility bears advantages of simple in construction, easy to operate, safe, reliable and efficient in source utilization

  12. HANARO fuel irradiation test(II)

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, D. S.; Kim, H. R.; Chae, H. T.; Lee, B. C.; Lee, C. S.; Kim, B. G.; Lee, C. B.; Hwang, W

    2001-04-01

    In order to fulfill the requirement to prove HANARO fuel integrity when irradiated at a power greater than 112.8 kW/m, which was imposed during HANARO licensing, and to verify the irradiation performance of HANARO fuel, the in-pile irradiation test of HANARO fuel has been performed. Two types of test fuel, the un-instrumented Type A fuel for higher burnup irradiation in shorter period than the driver fuel and the instrumented Type B fuel for higher linear heat rate and precise measurement of irradiation conditions, have been designed and fabricated. The test fuel assemblies were irradiated in HANARO. The two Type A fuel assemblies were intended to be irradiated to medium and high burnup and have been discharged after 69.9 at% and 85.5 at% peak burnup, respectively. Type B fuel assembly was intended to be irradiatied at high power with different instrumentations and achieved a maximum power higher than 120 kW/m without losing its integrity and without showing any irregular behavior. The Type A fuel assemblies were cooled for about 6 months and transported to the IMEF(Irradiated Material Examination Facility) for consequent evaluation. Detailed non-destructive and destructive PIE (Post-Irradiation Examination), such as the measurement of burnup distribution, fuel swelling, clad corrosion, dimensional changes, fuel rod bending strength, micro-structure, etc., has been performed. The measured results have been analysed/compared with the predicted performance values and the design criteria. It has been verified that HANARO fuel maintains proper in-pile performance and integrity even at the high power of 120 kw/m up to the high burnup of 85 at%.

  13. Performance of Shiva as a laser fusion irradiation facility

    International Nuclear Information System (INIS)

    Speck, D.R.; Bliss, E.S.; Glaze, J.A.; Johnson, B.C.; Manes, K.R.; Ozarski, R.G.; Rupert, P.R.; Simmons, W.W.; Swift, C.D.; Thompson, C.E.

    1979-01-01

    Shiva is a 20 beam Nd:Glass Laser and Target Irradiation Facility at the Lawrence Livermore Laboratory. The laser system and integrated target facility evolved during the last year from a large, untested, experimental laser system to a target irradiation facility which has provided significant laser driven inertial confinement fusion data. The operation of the facility is discussed

  14. Experimental Breeder Reactor II (EBR-II) Fuel-Performance Test Facility (FPTF)

    International Nuclear Information System (INIS)

    Pardini, J.A.; Brubaker, R.C.; Veith, D.J.; Giorgis, G.C.; Walker, D.E.; Seim, O.S.

    1982-01-01

    The Fuel-Performance Test Facility (FPTF) is the latest in a series of special EBR-II instrumented in-core test facilities. A flow control valve in the facility is programmed to vary the coolant flow, and thus the temperature, in an experimental-irradiation subassembly beneath it and coupled to it. In this way, thermal transients can be simulated in that subassembly without changing the temperatures in surrounding subassemblies. The FPTF also monitors sodium flow and temperature, and detects delayed neutrons in the sodium effluent from the experimental-irradiation subassembly beneath it. This facility also has an acoustical detector (high-temperature microphone) for detecting sodium boiling

  15. Radiation facilities and irradiation technology for food irradiation

    International Nuclear Information System (INIS)

    Sunaga, Hiromi

    2005-01-01

    Progress made during these 30 years in the field of radiation treatment of food is reviewed by describing features of the process including elementary processes, quality control of the products and the dosimetric techniques widely employed. The Co-60 gamma-ray irradiation facilities to be used for radiation-sterilization of medical supplies and food preservation are presented. For electron beam irradiation, accelerators for processing with the energy from 0.3 to 10 MeV are generally employed. The electron-guns, the method of acceleration such as rectification, types of acceleration as Cockcroft-Walton, dynamitron, or linear acceleration and X-ray producing facility, with various countermeasures for safety management, are briefly explained. The concepts of dose and traceability are given. The dosimeters including reference dosimeter and routine ones with validation are explained. (S. Ohno)

  16. Standard irradiation facilities for use in TRIGA reactors

    International Nuclear Information System (INIS)

    Kolbasov, B.N.; Luse, R.A.

    1972-01-01

    The standard neutron irradiation facility (SNIP) was developed under IAEA and FAO co-ordinated research program for the standardization of neutron irradiation facilities for radiobiological research, resulting in the possibility to use fast neutrons from pool-type reactors for radiobiological studies. The studies include irradiation of seeds for crop improvement, of Drosophila for genetic studies, and of microorganisms for developing industrially useful mutants, as well as fundamental studies in radiation biology. The facilities, located in the six pool-type reactors (in Austria, Bulgaria, India, Philippines, Thailand and Taiwan), have been calibrated and utilized to compare the response to fast neutrons of barley seeds (variety Himalaya CI 000620) which were selected as a standard biological monitor by which to estimate neutron fluxes in different reactors. These comparative irradiation studies showed excellent agreement and reproducibility

  17. The advanced test reactor national scientific user facility advancing nuclear technology

    International Nuclear Information System (INIS)

    Allen, T.R.; Thelen, M.C.; Meyer, M.K.; Marshall, F.M.; Foster, J.; Benson, J.B.

    2009-01-01

    To help ensure the long-term viability of nuclear energy through a robust and sustained research and development effort, the U.S. Department of Energy (DOE) designated the Advanced Test Reactor and associated post-irradiation examination facilities a National Scientific User Facility (ATR NSUF), allowing broader access to nuclear energy researchers. The mission of the ATR NSUF is to provide access to world-class nuclear research facilities, thereby facilitating the advancement of nuclear science and technology. The ATR NSUF seeks to create an engaged academic and industrial user community that routinely conducts reactor-based research. Cost free access to the ATR and PIE facilities is granted based on technical merit to U.S. university-led experiment teams conducting non-proprietary research. Proposals are selected via independent technical peer review and relevance to DOE mission. Extensive publication of research results is expected as a condition for access. During FY 2008, the first full year of ATR NSUF operation, five university-led experiments were awarded access to the ATR and associated post-irradiation examination facilities. The ATR NSUF has awarded four new experiments in early FY 2009, and anticipates awarding additional experiments in the fall of 2009 as the results of the second 2009 proposal call. As the ATR NSUF program mature over the next two years, the capability to perform irradiation research of increasing complexity will become available. These capabilities include instrumented irradiation experiments and post-irradiation examinations on materials previously irradiated in U.S. reactor material test programs. The ATR critical facility will also be made available to researchers. An important component of the ATR NSUF an education program focused on the reactor-based tools available for resolving nuclear science and technology issues. The ATR NSUF provides education programs including a summer short course, internships, faculty-student team

  18. HANARO fuel irradiation test (II): revision

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, D. S.; Kim, H.; Chae, H. T.; Lee, C. S.; Kim, B. G.; Lee, C. B

    2001-04-01

    In order to fulfill the requirement to prove HANARO fuel integrity when irradiated at a power greater than 112.8 kW/m, which was imposed during HANARO licensing, and to verify the irradiation performance of HANARO fuel, the in-pile irradiation test of HANARO fuel has been performed. Two types of test fuel, the un-instrumented Type A fuel for higher burnup irradiation in shorter period than the driver fuel and the instrumented Type B fuel for higher linear heat rate and precise measurement of irradiation conditions, have been designed and fabricated. The test fuel assemblies were irradiated in HANARO. The two Type A fuel assemblies were intended to be irradiated to medium and high burnup and have been discharged after 69.9 at% and 85.5 at% peak burnup, respectively. Type B fuel assembly was intended to be irradiated at high power with different instrumentations and achieved a maximum power higher than 120 kW/m without losing its integrity and without showing any irregular behavior. The Type A fuel assemblies were cooled for about 6 months and transported to the IMEF(Irradiated Material Examination Facility) for consequent evaluation. Detailed non-destructive and destructive PIE (Post-Irradiation Examination), such as the measurement of burnup distribution, fuel swelling, clad corrosion, dimensional changes, fuel rod bending strength, micro-structure, etc., has been performed. The measured results have been analysed/compared with the predicted performance values and the design criteria. It has been verified that HANARO fuel maintains proper in-pile performance and integrity even at the high power of 120 kw/m up to the high burnup of 85 at%. This report is the revision of KAERI/TR-1816/2001 on the irradiation test for HANARO fuel.

  19. UTN's gamma irradiation facility: design and concept

    International Nuclear Information System (INIS)

    Mohamad Noor Mohamad Yunus

    1986-01-01

    UTN is building a multipurpose gamma irradiation facility which compromises of research and pilot scale irradiation cells in The Fifth Malaysia Plan. The paper high-lights the basic futures of the facility in terms of its design and selection including layout sketches. Plant performances and limitations are discussed. Plants safety is briefly highlighted in block diagrams. Lastly, a typical specification brief is tabled in appendix for reference purposes. (author)

  20. The accomplishments of lithium target and test facility validation activities in the IFMIF/EVEDA phase

    Science.gov (United States)

    Arbeiter, Frederik; Baluc, Nadine; Favuzza, Paolo; Gröschel, Friedrich; Heidinger, Roland; Ibarra, Angel; Knaster, Juan; Kanemura, Takuji; Kondo, Hiroo; Massaut, Vincent; Saverio Nitti, Francesco; Miccichè, Gioacchino; O'hira, Shigeru; Rapisarda, David; Sugimoto, Masayoshi; Wakai, Eiichi; Yokomine, Takehiko

    2018-01-01

    As part of the engineering validation and engineering design activities (EVEDA) phase for the international fusion materials irradiation facility IFMIF, major elements of a lithium target facility and the test facility were designed, prototyped and validated. For the lithium target facility, the EVEDA lithium test loop was built at JAEA and used to test the stability (waves and long term) of the lithium flow in the target, work out the startup procedures, and test lithium purification and analysis. It was confirmed by experiments in the Lifus 6 plant at ENEA that lithium corrosion on ferritic martensitic steels is acceptably low. Furthermore, complex remote handling procedures for the remote maintenance of the target in the test cell environment were successfully practiced. For the test facility, two variants of a high flux test module were prototyped and tested in helium loops, demonstrating their good capabilities of maintaining the material specimens at the desired temperature with a low temperature spread. Irradiation tests were performed for heated specimen capsules and irradiation instrumentation in the BR2 reactor at SCK-CEN. The small specimen test technique, essential for obtaining material test results with limited irradiation volume, was advanced by evaluating specimen shape and test technique influences.

  1. User Support of Electron Irradiation Facility

    International Nuclear Information System (INIS)

    Park, S. H.; Cha, H. K.; Lee, B. C.

    2007-06-01

    The KAERI (Korean Atomic Energy Research Institute) high-power electron beam irradiation facility, operating at the energies between 0.3 MeV and 10 MeV,has provided irradiation services to users in industries, universities, and institutes via 'Project of utilization and cooperation of users of a large research facility' since 2004. A great attraction of many researchers, almost 750 persons so far according to surveys, to e-beam irradiation technology as well as the growth of participants on Workshop on Electron Beam Applications from 121 to 176 indicate the increase of demands of irradiation service. Comparing to the cases of advanced nations in this area, such as America, Japan, China, and Russia, Korea is relatively much behind in radiation technology. It is mainly due to the lack of governmental supports and investments. Active support and investment on construction and operation of electron beam user facilities would be principal factors on developments of advanced technologies. In this project, we would like to satisfy users' requests by developing the effective managing and operating system for prompt services, processes, and QA and to ultimately assist users to create additional new results, by maximizing the utilization of all available resources and activating the developments of technologies of electron beam processing

  2. Fusion Materials Irradiation Test (FMIT) facility lithium system: a design and development status

    International Nuclear Information System (INIS)

    Brackenbury, P.J.; Bazinet, G.D.; Miller, W.C.

    1983-01-01

    The design and development of the Fusion Materials Irradiation Test (FMIT) Facility lithium system is outlined. This unique liquid lithium recirculating system, the largest of its kind in the world, is described with emphasis on the liquid lithium target assembly and other important components necessary to provide lithium flow to the target. The operational status and role of the Experimental Lithium System (ELS) in the design of the FMIT lithium system are discussed. Safety aspects of operating the FMIT lithium system in a highly radioactive condition are described. Potential spillage of the lithium is controlled by cell liners, by argon flood systems and by remote maintenance features. Lithium chemistry is monitored and controlled by a side-stream loop, where impurities measured by instruments are collected by hot and cold traps

  3. Fusion Materials Irradiation Test (FMIT) facility lithium system: a design and development status

    Energy Technology Data Exchange (ETDEWEB)

    Brackenbury, P.J.; Bazinet, G.D.; Miller, W.C.

    1983-01-01

    The design and development of the Fusion Materials Irradiation Test (FMIT) Facility lithium system is outlined. This unique liquid lithium recirculating system, the largest of its kind in the world, is described with emphasis on the liquid lithium target assembly and other important components necessary to provide lithium flow to the target. The operational status and role of the Experimental Lithium System (ELS) in the design of the FMIT lithium system are discussed. Safety aspects of operating the FMIT lithium system in a highly radioactive condition are described. Potential spillage of the lithium is controlled by cell liners, by argon flood systems and by remote maintenance features. Lithium chemistry is monitored and controlled by a side-stream loop, where impurities measured by instruments are collected by hot and cold traps.

  4. IRASM - A multipurpose irradiation facility in Romania

    International Nuclear Information System (INIS)

    Ponta, C.C.; Moise, I.V.; Bratu, E.

    1998-01-01

    A multipurpose irradiation facility is under construction at IPNE, Bucharest, under the IAEA T.C. Project: ROM/8/011. It will be the first industrial facility in Romania. This paper presents the philosophy standing behind the design, the short and long term managing plans. Some dose calculations are added in the view of using the empty spaces in the irradiation room for cultural heritage conservation. An economic study is presented aiming to provide basic estimations for further management strategy. At the start the facility will be a state enterprise. The implications, advantages and disadvantages of this situation are discussed

  5. IFMIF - International Fusion Materials Irradiation Facility Conceptual Design Activity/Interim Report

    International Nuclear Information System (INIS)

    Rennich, M.J.

    1995-12-01

    Environmental acceptability, safety, and economic viability win ultimately be the keys to the widespread introduction of fusion power. This will entail the development of radiation- resistant and low- activation materials. These low-activation materials must also survive exposure to damage from neutrons having an energy spectrum peaked near 14 MeV with annual radiation doses in the range of 20 displacements per atom (dpa). Testing of candidate materials, therefore, requires a high-flux source of high energy neutrons. The problem is that there is currently no high-flux source of neutrons in the energy range above a few MeV. The goal, is therefore, to provide an irradiation facility for use by fusion material scientists in the search for low-activation and damage-resistant materials. An accellerator-based neutron source has been established through a number of international studies and workshops' as an essential step for materials development and testing. The mission of the International Fusion Materials Irradiation Facility (IFMIF) is to provide an accelerator-based, deuterium-lithium (D-Li) neutron source to produce high energy neutrons at sufficient intensity and irradiation volume to test samples of candidate materials up to about a full lifetime of anticipated use in fusion energy reactors. would also provide calibration and validation of data from fission reactor and other accelerator-based irradiation tests. It would generate material- specific activation and radiological properties data, and support the analysis of materials for use in safety, maintenance, recycling, decommissioning, and waste disposal systems

  6. Conceptual design for simulator of irradiation test reactors

    International Nuclear Information System (INIS)

    Takemoto, Noriyuki; Ohto, Tsutomu; Magome, Hirokatsu; Izumo, Hironobu; Hori, Naohiko

    2012-03-01

    A simulator of irradiation test reactors has been developed since JFY 2010 for understanding reactor behavior and for upskilling in order to utilize a nuclear human resource development (HRD) and to promote partnership with developing countries which have a plan to introduce nuclear power plant. The simulator is designed based on the JMTR, one of the irradiation test reactors, and it simulates operation, irradiation tests and various kinds of accidents caused by the reactor and irradiation facility. The development of the simulator is sponsored by the Japanese government as one of the specialized projects of advanced research infrastructure in order to promote basic as well as applied researches. The training using the simulator will be started for the nuclear HRD from JFY 2012. This report summarizes the result of the conceptual design of the simulator in JFY 2010. (author)

  7. Radiation safety of gamma and electron irradiation facilities

    International Nuclear Information System (INIS)

    1992-01-01

    There are currently some 160 gamma irradiation facilities and over 600 electron beam facilities in operation throughout virtually all Member States of the IAEA. The most widespread uses of these facilities are for the sterilization of medical and pharmaceutical products, the preservation of foodstuffs, polymer synthesis and modification, and the eradication of insect infestation. The safety record of this industry has been very good. Nevertheless, there is a potential for accidents with serious consequences. Gamma and electron beam facilities produce very high dose rates during irradiation, so that a person accidentally present in the irradiation chamber can receive a lethal dose within minutes or seconds. Precautions against uncontrolled entry must therefore be taken. Furthermore, gamma irradiation facilities contain large amounts of radioactivity and if the mechanism for retracting the source is damaged, the source may remain exposed, inhibiting direct access to carry out remedial work. Contamination can result from corroded or damaged sources, and decontamination can be very expensive. These aspects clearly indicate the need to achieve a high degree of safety and reliability in the facilities. This can be accomplished by effective quality control together with careful design, manufacture, installation, operation and decommissioning. The guidance in this Safety Series publication is intended for competent authorities responsible for regulating the use of radiation sources as well as the manufacturers, suppliers, installers and users of gamma and electron beam facilities. 20 refs, 6 figs

  8. Irradiation testing of coated particle fuel at Hanaro

    International Nuclear Information System (INIS)

    Goo Kim, Bong; Sung Cho, Moo; Kim, Yong Wan

    2014-01-01

    TRISO-coated particle fuel is developing to support development of VHTR in Korea. From August 2013, the first irradiation testing of coated particle fuel was begun to demonstrate and qualify TRISO fuel for use in VHTR in the HANARO at KAERI. This experiment is currently undergoing under the atmosphere of a mixed inert gas without on-line temperature monitoring and control combined with on-line fission product monitoring of the sweep gas. The irradiation device contains two test rods, one contains nine fuel compacts and the other five compacts and eight graphite specimens. Each compact has 263 coated particles. After a peak burn-up of about 4 at% and a peak fast neutron fluence of about 1.7 x 10 21 n/cm 2 , PIE will be carried out at KAERI's Irradiated Material Examination Facility. This paper is described characteristics of coated particle fuel, the design of test rod and irradiation device for coated particle fuel, discusses the technical results for irradiation testing at HANARO. (authors)

  9. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  10. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  11. A GIF++ Gamma Irradiation Facility at the SPS H4 Beam Line

    CERN Document Server

    Capéans-Garrido, M; Linssen, L; Moll, M; Rembser, C

    2009-01-01

    The current document describes a proposal to implement a new gamma irradiation facility, combined with a high-energy particle beam in the SPS H4 beam line in hall EHN1. This new GIF++ facility is motivated by strong needs from the LHC and sLHC detector and accelerator communities for the tests of LHC components and systems.

  12. Description of the PIE facility for research reactors irradiated fuels in CNEA

    International Nuclear Information System (INIS)

    Bisca, A.; Coronel, R.; Homberger, V.; Quinteros, A.; Ratner, M.

    2002-01-01

    The PIE Facility (LAPEP), located at the Ezeiza Atomic Center (CAE), was designed to carry out destructive and non-destructive post-irradiation examinations (PIE) on research and power reactor spent fuels, reactor internals and other irradiated materials, and to perform studies related with: Station lifetime extension; Fuel performance; Development of new fuels; and Failures and determination of their causes. LAPEP is a relevant facility where research and development can be carried out. It is worth mentioning that in this facility the PIE corresponding to the Surveillance Program for the Atucha I Nuclear Power Plant (CNA-1) were successfully performed. Materials testing during the CNA-1 repair and the study of failures in fuel element plugs of the Embalse Nuclear Power Plant (CNE) were also performed. (author)

  13. Results from the CDE phase activity on neutron dosimetry for the international fusion materials irradiation facility test cell

    Energy Technology Data Exchange (ETDEWEB)

    Esposito, B. E-mail: esposito@frascati.enea.it; Bertalot, L.; Maruccia, G.; Petrizzi, L.; Bignan, G.; Blandin, C.; Chauffriat, S.; Lebrun, A.; Recroix, H.; Trapp, J.P.; Kaschuck, Y

    2000-11-01

    The international fusion materials irradiation facility (IFMIF) project deals with the study of an accelerator-based, deuterium-lithium source, producing high energy neutrons at sufficient intensity and irradiation volume to test samples of candidate materials for fusion energy reactors. IFMIF would also provide calibration and validation of data from fission reactor and other accelerator based irradiation tests. This paper describes the activity on neutron/gamma dosimetry (necessary for the characterization of the specimens' irradiation) performed in the frame of the IFMIF conceptual design evaluation (CDE) neutronics tasks. During the previous phase (conceptual design activity (CDA)) the multifoil activation method was proposed for the measurement of the neutron fluence and spectrum and a set of suitable foils was defined. The cross section variances and covariances of this set of foils have now been used for tests on the sensitivity of the IFMIF neutron spectrum determination to cross section uncertainties. The analysis has been carried out using the LSL-M2 code, which optimizes the neutron spectrum by means of a least-squares technique taking into account the variance and covariance files. In the second part of the activity, the possibility of extending to IFMIF the use of existing on-line in-core neutron/gamma monitors (to be located at several positions inside the IFMIF test cell for beam control, safety and diagnostic purposes) has been studied. A feasibility analysis of the modifications required to adapt sub-miniature fission chambers (recently developed by CEA-Cadarache) to the high flux test module of the test cell has been carried out. The verification of this application pertinence and a gross definition of the in-core detector characteristics are described. The option of using self-powered neutron detectors (SPNDs) is also discussed.

  14. Post irradiation examinations cooperation and worldwide utilization of facilities

    International Nuclear Information System (INIS)

    Karlsson, Mikael

    2009-01-01

    Status of post irradiation examinations in Studsvik's facilities, cooperation and worldwide utilization of facilities, was described. Studsvik cooperate with irradiation facilities, as Halden, CEA and JAEA, as well as other hot cell facilities (examples, PSI, ITU and NFD) universities (example, the Royal Institute of Technology in Sweden) in order to be able to provide everything asked for by the nuclear community. Worldwide cooperation for effective use of expensive and highly specialized facilities is important, and the necessity of cooperation will be more and more recognized in the future. (author)

  15. New irradiation facilities at the Australian national medical cyclotron

    International Nuclear Information System (INIS)

    Parcell, S.K.; Arnott, D.W.; Conard, E.M.

    1999-01-01

    Two new irradiation facilities have been developed at the National Medical Cyclotron for radionuclide production. The first relocates PET irradiations from the cyclotron vault to a dedicated PET beam room, to improve accessibility and reduce radiation exposures associated with target maintenance. This new facility consists of a beam line to transport 16-30 MeV proton beams from the cyclotron to 1 of 8 PET targets mounted on a target rack. The target rack has increased the number of targets available for production and experimentation. The second is a completely independent solid target irradiation facility for SPECT. This facility consists of a beam line to transport 26-30 MeV proton beams from the cyclotron to a dedicated beam room containing one solid target station. A new pneumatic target transfer system was also developed to transport the solid target to and from the existing chemistry hot cells. The beam line and target components are operated under the control of a dedicated PLC with a PC based user interface. The development and some technical aspects of these new irradiation facilities are discussed here. (author)

  16. Design of a single variable helium effects experiment for irradiation in FFTF [Fast Flux Test Facility] using alloys enriched in nickel 59

    International Nuclear Information System (INIS)

    Simons, R.L.; Brager, H.R.; Matsumoto, W.Y.

    1986-03-01

    Nickel enriched in nickel 59 was extracted from the fragments of a fracture toughness specimen of Inconel 600 irradiated in the Engineering Test Reactor (ETR). The nickel contained 2.0% nickel 59. Three heats of austenitic steel doped with nickel-59 were prepared and inserted in the Materials Open Test Assembly (MOTA) of the Fast Flux Test Facility (FFTF). The experiment was single variable in helium effects because chemically identical alloys without nickel-59 were being irradiated side by side with the doped material. The alloys doped with nickel 59 produced 10 to 100 times more helium than the control alloys. The materials included ternary and quaternary alloys in the form of transmission electron microscope (TEM) discs and miniature tensile specimens. The helium to dpa ratio was in the range 5 to 35 and was nearly constant throughout the irradiation. The exposures ranged from 0.25 to 50 displacements per atom (dpa) over the duration of the experiment. The irradiation temperatures covered the range of 360 to 600 0 C

  17. Irradiation Testing of TRISO-Coated Particle Fuel in Korea

    International Nuclear Information System (INIS)

    Kim, Bong Goo; Yeo, Sunghwan; Jeong, Kyung-Chai; Eom, Sung-Ho; Kim, Yeon-Ku; Kim, Woong Ki; Lee, Young Woo; Cho, Moon Sung; Kim, Yong Wan

    2014-01-01

    In Korea, coated particle fuel is being developed to support development of a VHTR. At the end of March 2014, the first irradiation test in HANARO at KAERI to demonstrate and qualify TRISO-coated particle fuel for use in a VHTR was terminated. This experiment was conducted in an inert gas atmosphere without on-line temperature monitoring and control, or on-line fission product monitoring of the sweep gas. The irradiation device contained two test rods, one has nine fuel compacts and the other five compacts and eight graphite specimens. Each compact contains about 260 TRISO-coated particles. The duration of irradiation testing at HANARO was about 135 full power days from last August 2013. The maximum average power per particle was about 165 mW/particle. The calculated peak burnup of the TRISO-coated fuel was a little less than 4 atom percent. Post-irradiation examination is being carried out at KAERI’s Irradiated Material Examination Facility beginning in September of 2014. This paper describes characteristics of coated particle fuel, the design of the test rod and irradiation device for this coated particle fuel, and discusses the technical results of irradiation testing at HANARO. (author)

  18. MYRRHA, A Flexible Fast Spectrum Irradiation Facility. Current Status of Design

    International Nuclear Information System (INIS)

    Baeten, Peter; Fernandez, Rafaël; De Bruyn, Didier; Van den Eynde, Gert; Leysen, Paul; Aït Abderrahim, Hamid; Castelliti, Diego

    2011-01-01

    R and D program in support of MYRRHA: • Several R&D required for MYRRHA components: - LBE corrosion; - O 2 control in LBE; - Irradiated material properties. • Experimental facilities foreseen in the near future in support of MYRRHA at SCK•CEN premacies: - E-SCAPE: Thermal-hydraulic pool facility with 1:6 scale ratio with MYRRHA; - Liliputter: Pump test loop; - COMPLOT: Isothermal hydraulic loop representing one fuel channel/IPS at full high; - PHX mock-up testing concept, fouling, flow-induced vibrations, (SGTR)…; • Experimental facilities foreseen in the near future in support of MYRRHA at SCK•CEN premacies (continued): - Safety/control rod; - Fuel bundle; - Target window; - Component test pool; - Fuel loader; - Robotic arm; • All experiments planned to be finished before 2016

  19. Fuels and materials research under the high neutron fluence using a fast reactor Joyo and post-irradiation examination facilities

    International Nuclear Information System (INIS)

    Soga, Tomonori; Ito, Chikara; Aoyama, Takafumi; Suzuki, Soju

    2009-01-01

    The experimental fast reactor Joyo at Oarai Research and Development Center (ORDC) of Japan Atomic Energy Agency (JAEA) is Japan's sodium-cooled fast reactor (FR). In 2003, this reactor's upgrade to the 140MWt MK-III core was completed to increase the irradiation testing capability. The MK-III core provides the fast neutron flux of 4.0x10 15 n/cm 2 s as an irradiation test bed for improving the fuels and material of FR in Japan. Three post-irradiation examination (PIE) facilities named FMF, MMF and AGF related to Joyo are in ORDC. Irradiated subassemblies and core components are carried into the FMF (Fuel Monitoring Facility) and conducted nondestructive examinations. Each subassembly is disassembled to conduct some destructive examinations and to prepare the fuel and material samples for further detailed examinations. Fuel samples are sent to the AGF (Alpha-Gamma Facility), and material samples are sent to the MMF (Materials Monitoring Facility). These overall and elaborate data provided by PIE contribute to investigate the irradiation effect and behavior of fuels and materials. This facility complex is indispensable to promote the R and D of FR in Japan. And, the function and technology of irradiation test and PIE enable to contribute to the R and D of innovative fission or fusion reactor material which will be required to use under the high neutron exposure. (author)

  20. Microstructural examination of 12% Cr martensitic stainless steel after irradiation at elevated temperatures in FFTF [Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Hsu, Chen-Yih; Gelles, D.S.; Lechtenberg, T.A.

    1986-06-01

    A remelted 12% Cr martensitic stainless steel (HT-9) has been examined by transmission electron microscopy before and after irradiation in the Materials Open Test Assembly (MOTA) of the Fast Flux Test Facility (FFTF). The irradiation temperatures were 365,420, 520, and 600 degree C with the fluences as high as 7.3 x 10 22 n/cm 2 (E > 0.1 MeV) or 34 dpa. The extracted precipitates from each specimen were identified using x-ray microanalysis and selected area diffraction. The precipitates in the unirradiated condition were primarily M 23 C 6 carbides, which formed at martensite lath and prior austenite grain boundaries. During irradiation at elevated temperatures, small amounts of other phases formed, which were tentatively identified as the chromium-rich α', the nickel-silicon rich G-phase, and the intermetallic Chi phase. Irradiation-induced voids were observed only in specimens irradiated at 420 degree C to a dose of 34 dpa; no voids were found for specimens irradiated at 365, 520, and 600 degree C (∼11, ∼34, and ∼34 dpa). These results are not in agreement with previous experiments in that voids have not been reported in this alloy at relatively high fluence level (∼67 dpa) following irradiation in another fast-spectrum reactor (EBR.II). This is, however, the first observation following FFTF irradiation. The present results indicate that cavities can form in HT-9 at modest fluence levels even without significant generation of helium. Hence, the cavity formation in this class of ferritic alloys is not simply caused by helium generation but rather more complex mechanisms. 12 refs., 2 figs., 3 tabs

  1. Preliminary test results for post irradiation examination on the HTTR fuel

    International Nuclear Information System (INIS)

    Ueta, Shohei; Umeda, Masayuki; Sawa, Kazuhiro; Sozawa, Shizuo; Shimizu, Michio; Ishigaki, Yoshinobu; Obata, Hiroyuki

    2007-01-01

    The future post-irradiation program for the first-loading fuel of the HTTR is scheduled using the HTTR fuel handling facilities and the Hot Laboratory in the Japan Materials Testing Reactor (JMTR) to confirm its irradiation resistance and to obtain data on its irradiation characteristics in the core. This report describes the preliminary test results and the future plan for a post-irradiation examination for the HTTR fuel. In the preliminary test, fuel compacts made with the same SiC-coated fuel particle as the first loading fuel were used. In the preliminary test, dimension, weight, fuel failure fraction, and burnup were measured, and X-ray radiograph, SEM, and EPMA observations were carried out. Finally, it was confirmed that the first-loading fuel of the HTTR showed good quality under an irradiation condition. The future plan for the post-irradiation tests was described to confirm its irradiation performance and to obtain data on its irradiation characteristics in the HTTR core. (author)

  2. Irradiation and experimental facilities at Dhruva

    International Nuclear Information System (INIS)

    Chakrabarty, Kunal; Mondal, Samir

    2006-01-01

    Research reactors are utilized to produce radioisotopes and offer irradiation facilities for testing various nuclear materials such as fuel and structural materials. Apart from providing large volume of neutron source for carrying out a variety of experiments, the research reactor forms the basic training ground for grooming up scientists and engineers for the various aspects of nuclear programme. Dhruva one of the high flux research reactors offers a maximum neutron flux level of 1.8 x 10 14 n/cm 2 /sec. It uses natural metallic uranium fuel with aluminium cladding and heavy water as coolant, moderator and reflector

  3. Low temperature irradiation facility at Kyoto University Reactor (KUR)

    International Nuclear Information System (INIS)

    Atobe, Kozo; Okada, Moritami; Yoshida, Hiroyuki; Kodaka, Hisao; Miyata, Kiyomi.

    1977-01-01

    A new refrigeration system has been substituted to the low temperature irradiation facility at KUR instead of the previous one, since April in 1975. The model 1204 CTi He liquifier was designed to be modified for the refrigerator with the capacity of 30 watts at 10 K. The refrigeration capacity of 38 watts at 10 K was defined using a special cryostat and transfer-tubes, and the lowest temperature of about 18 K was measured using the irradiation loop without reactor operation. The reconstructed facility enables us to hold the many specimens simultaneously in the sample chamber of the irradiation loop at about 25 K during reactor operation of 5 MW. The irradiation dose has been reached about 6.6 x 10 16 n sub(f)/cm 2 and 6.1 x 10 17 n sub(th)/cm 2 with the normal reactor operation cycle of up to 77 hours. The stable operation condition of the machine and the special safety system for the refrigeration system enable us to maintain easily the facility with a constant operation condition for such a long time irradiation. Many kinds of low temperature neutron irradiation experiments are carried out using the facility, which techniques are partially reported. (auth.)

  4. Study on increasing commercial benefits of 60Co irradiation facilities

    International Nuclear Information System (INIS)

    Yang Shuizi; Qi Huanjiang; Xei Tong

    2004-01-01

    Estimating commercial benefits of irradiation facilities adopts commercial benefits coefficient. The effect factors are the utilization rate of irradiation energy (E), the consistency of irradiation facilities (Ci), the utilization rate of time (T), the utilization rate of space, the minimum efficient adsorption dose (Dmin), the irradiation adsorption dose uriformity (U), the sale (S), the running cost (C) et. al, and E, Ci, S, C are main in all factors. (authors)

  5. Technical Safety Requirements for the Gamma Irradiation Facility (GIF)

    CERN Document Server

    Mahn, J A E M J G

    2003-01-01

    This document provides the Technical Safety Requirements (TSR) for the Sandia National Laboratories Gamma Irradiation Facility (GIF). The TSR is a compilation of requirements that define the conditions, the safe boundaries, and the administrative controls necessary to ensure the safe operation of a nuclear facility and to reduce the potential risk to the public and facility workers from uncontrolled releases of radioactive or other hazardous materials. These requirements constitute an agreement between DOE and Sandia National Laboratories management regarding the safe operation of the Gamma Irradiation Facility.

  6. Upgrading safety systems of industrial irradiation facilities

    International Nuclear Information System (INIS)

    Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C.; Costa, M.L.L.; Thomé, Z.D.

    2017-01-01

    The first industrial irradiation facility in operation in Brazil was designed in the 70s. Nowadays, twelve commercial and research facilities are in operation and two already decommissioned. Minor modifications and upgrades, as sensors replacement, have been introduced in these facilities, in order to reduce the technological gap in the control and safety systems. The safety systems are designed in agreement with the codes and standards at the time. Since then, new standards, codes and recommendations, as well as lessons learned from accidents, have been issued by various international committees or regulatory bodies. The rapid advance of the industry makes the safety equipment used in the original construction become obsolete. The decreasing demand for these older products means that they are no longer produced, which can make it impossible or costly to obtain spare parts and the expansion of legacy systems to include new features. This work aims to evaluate existing safety systems at Brazilian irradiation facilities, mainly the oldest facilities, taking into account the recommended IAEA's design requirements. Irrespective of the fact that during its operational period no event with victims have been recorded in Brazilian facilities, and that the regulatory inspections do not present any serious deviations regarding the safety procedures, it is necessary an assessment of safety system with the purpose of bringing their systems to 'the state of the art', avoiding their rapid obsolescence. This study has also taken into account the knowledge, concepts and solutions developed to upgrading safety system in irradiation facilities throughout the world. (author)

  7. Upgrading safety systems of industrial irradiation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C.; Costa, M.L.L., E-mail: rogeriog@cnen.gov.br, E-mail: jlopes@cnen.gov.br, E-mail: evaldo@cnen.gov.br, E-mail: mara@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear; Thomé, Z.D., E-mail: zielithome@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-07-01

    The first industrial irradiation facility in operation in Brazil was designed in the 70s. Nowadays, twelve commercial and research facilities are in operation and two already decommissioned. Minor modifications and upgrades, as sensors replacement, have been introduced in these facilities, in order to reduce the technological gap in the control and safety systems. The safety systems are designed in agreement with the codes and standards at the time. Since then, new standards, codes and recommendations, as well as lessons learned from accidents, have been issued by various international committees or regulatory bodies. The rapid advance of the industry makes the safety equipment used in the original construction become obsolete. The decreasing demand for these older products means that they are no longer produced, which can make it impossible or costly to obtain spare parts and the expansion of legacy systems to include new features. This work aims to evaluate existing safety systems at Brazilian irradiation facilities, mainly the oldest facilities, taking into account the recommended IAEA's design requirements. Irrespective of the fact that during its operational period no event with victims have been recorded in Brazilian facilities, and that the regulatory inspections do not present any serious deviations regarding the safety procedures, it is necessary an assessment of safety system with the purpose of bringing their systems to 'the state of the art', avoiding their rapid obsolescence. This study has also taken into account the knowledge, concepts and solutions developed to upgrading safety system in irradiation facilities throughout the world. (author)

  8. Questionnaire survey and technical guideline of blood irradiation on medical facilities

    International Nuclear Information System (INIS)

    Matsumoto, Mitsuhiro; Hasegawa, Hironori; Okumura, Masahiko; Sonoda, Tatsuo; Osada, Koji.

    1997-01-01

    We know that transfusion-associated graft versus host disease (TA-GVHD) is a serious side effect associated with blood transfusion and the onset is independent on the immunological conditions of patients. We have only prophylactic treatment against TA-GVHD. The most reliable method is to irradiate the blood for transfusion. In Japanese medical facilities, however, the risk of TA-GVHD is poorly understood and actual conditions of the blood irradiation are unclear. We sent a questionnaire to randomly selected 426 medical facilities in Japan, which had the department of radiology, to investigate the actual conditions of blood irradiation for transfusion and the problems on the irradiation dose measurement of the external apparatus for blood irradiation. The questionnaire involved 19 questions about the blood irradiation for transfusion. The survey took place for one month (June 1-June 30, 1995). Replies were obtained from a total of 306 medical facilities (72%). The results showed that blood irradiation was done by several methods in the 75% of the medical facilities, and the external irradiation apparatus was used in 83%. Some problems were shown, including irradiation period, cost of the irradiation, the operating procedure of the apparatus, requested number of the irradiation, and the request after usual hours. There was no significant problem on the irradiation dose, irradiation method, etc. We also sent a questionnaire to 74 facilities of the Red Cross Blood Center, in which the frequency of blood irradiation have increased since May, 1976. The X-ray apparatus as the external irradiation apparatus has practical advantages; lower cost, compact and out of the legal control on the ionizing radiation, however, it has some problems on the uniformity of the absorption dose when a single X-ray tube-type apparatus is used. We discuss about the possible onset of TA-GVHD or other accidents by the incorrect irradiation of the blood preparations. (K.H.)

  9. Proceedings of the Seminar 'Irradiation Technologies and the IRASM Facility'

    International Nuclear Information System (INIS)

    Ponta, Corneliu Catalin; Moise, Ioan Valentin

    1999-01-01

    The seminar devoted to 'Irradiation Technologies and the IRASM Facility' aimed at debating the principal problems related to one of the most important project ever developed in Romania, at the Horia Hulubei National Institute of Physics and Nuclear Engineering, in collaboration with IAEA. IRASM (an acronym for Multiple Purpose Irradiation Facility) is using initially a 60 Co of 100 kCi irradiation source (to be replaced after an promotional stage by a 2 MCi Co source). It is designed to irradiate a materials volume of about 35,000 m 3 /year. Health, agriculture, food industry and materials industry are the most targeted customers. It will be used for sterilization of medical materials and pharmaceuticals products, peat and seed (and other agricultural products) decontamination and sterilization, experimental irradiation of food products, irradiation of composite plastics and other industrial products, etc. The seminar was a first meeting of Romanian specialists in radiation processing with potential users of these technologies as well as with decision making persons working with national governmental and regulation authorities. Twelve communications were presented as a basis for discussion. These were: 1. IRASM - a technical assistance IAEA project and the prospects for technological irradiation in Romania (Serban Dobrescu); 2. IRASM facility - goal, present stage, perspectives (Corneliu C. Ponta); 3. Nuclear safeguards and radioprotection at IRASM (Ioan Valentin Moise); 4. Nuclear safeguard policy for IRASM (Mariana Irimia, Gabriela Vladescu, Ion Cristian); 5. Technological dosimetry at IRASM (Rodica Macrin, Rodica Moraru, Nicolae Valcov); 6. Quality assurance in building and exploiting IRASM (Ioana Domsa); 7. Current status of irradiation technologies in IFIN-HH (Mitica Dragusin); 8. Chemical-pharmaceutical, cosmetic and medical product sterilization (Paul Adrian, Eleonora Gheorghiu); 9. The concept of sterilization and the sterilization testing (Ileana Petcu

  10. An overview of the PIREX Proton Irradiation facility and its research program

    Energy Technology Data Exchange (ETDEWEB)

    Victoria, M.; Gavillet, D. [Association EURATOM, Villigen (Switzerland)

    1995-10-01

    The main design characteristics of PIREX (Proton Irradiation Experiment) are described. The facility is installed in the 590 MeV proton beam of the PSI accelerator system. Its main task is the irradiation and testing of fusion reactor candidate materials. Protons of this energy produce simultaneously in the target material displacement damage and impurities, amongst them helium. They can therefore simulate possible synergistic effects between helium and damage that would result from irradiations with the fusion neutrons. The research program being developed includes studies on both materials of technological interest, such as martensitic stainless steels and Mo - based alloys and basic radiation damage research on pure metals. The facility is also being used for actinide transmutation studies, in the so called ATHENA experiment. The main directions of the research program are described and examples of present results are given.

  11. The proceedings of 1993-workshop on 'development and application of facilities for low temperature irradiation as well as controlled irradiation'

    International Nuclear Information System (INIS)

    Kuramoto, Eiichi; Okada, Moritami

    1993-03-01

    This is the proceedings of 1992-workshop of the working group on 'Development and Application of Facilities for Low Temperature Irradiation as well as Controlled Irradiation' held at the Research Reactor Institute of Kyoto University on February 23 and 24, 1993. In this workshop until now, studies on irradiation effects in many materials irradiated at lower and higher temperatures have been reported. It has been clearly defined that a careful choice of irradiation conditions is most important. At the present time, a setting plan of exactly controlled irradiation facility, which is able to irradiate with higher temperatures, is in progress. On the other hand, a plan of vertical low temperature irradiation facility has not yet been performed for lack of funds. In last year, a middle scale plan of low temperature irradiation facility, which is possible to irradiate a fast-neutron dose above 10 17 n/cm 2 at about 5K, was proposed in this workshop. In this proceedings, the advanced facility is required to construct to the KUR as soon as possible by many of the workshop members. (author)

  12. Irradiation and examination results of the AC-3 mixed-carbide test

    International Nuclear Information System (INIS)

    Mason, R.E.; Hoth, C.W.; Stratton, R.W.; Botta, F.

    1992-01-01

    The AC-3 test was a cooperative Swiss/US irradiation test of mixed-carbide, (U,Pr)C, fuel pins in the Fast Flux Test Facility. The test included 25 Swiss-fabricated sphere-pac-type fuel pins and 66 U.S. fabricated pellet-type fuel pins. The test was designed to operate at prototypical fast reactor conditions to provide a direct comparison of the irradiation performance of the two fuel types. The test design and fuel fabrication processes used for the AC-3 test are presented

  13. Linear Accelerator Test Facility at LNF Conceptual Design Report

    CERN Document Server

    Valente, Paolo; Bolli, Bruno; Buonomo, Bruno; Cantarella, Sergio; Ceccarelli, Riccardo; Cecchinelli, Alberto; Cerafogli, Oreste; Clementi, Renato; Di Giulio, Claudio; Esposito, Adolfo; Frasciello, Oscar; Foggetta, Luca; Ghigo, Andrea; Incremona, Simona; Iungo, Franco; Mascio, Roberto; Martelli, Stefano; Piermarini, Graziano; Sabbatini, Lucia; Sardone, Franco; Sensolini, Giancarlo; Ricci, Ruggero; Rossi, Luis Antonio; Rotundo, Ugo; Stella, Angelo; Strabioli, Serena; Zarlenga, Raffaele

    2016-01-01

    Test beam and irradiation facilities are the key enabling infrastructures for research in high energy physics (HEP) and astro-particles. In the last 11 years the Beam-Test Facility (BTF) of the DA{\\Phi}NE accelerator complex in the Frascati laboratory has gained an important role in the European infrastructures devoted to the development and testing of particle detectors. At the same time the BTF operation has been largely shadowed, in terms of resources, by the running of the DA{\\Phi}NE electron-positron collider. The present proposal is aimed at improving the present performance of the facility from two different points of view: extending the range of application for the LINAC beam extracted to the BTF lines, in particular in the (in some sense opposite) directions of hosting fundamental physics and providing electron irradiation also for industrial users; extending the life of the LINAC beyond or independently from its use as injector of the DA{\\Phi}NE collider, as it is also a key element of the electron/...

  14. Irradiation facilities on the TRIGA-SSR thermal column

    Energy Technology Data Exchange (ETDEWEB)

    Roth, C; Aioanei, L; Preda, M; Gugiu, D [Institute for Nuclear Research, Pitesti (Romania); Garlea, I; Kelerman, C; Garlea, C [SENDRA ' Nuclear Technologies' ltd. Bucharest (Romania)

    2004-07-01

    The development of thermal and intermediate energy neutron irradiation facilities at the steady state core of the Romanian TRIGA Reactor is described. The reference thermal neutron irradiation facility consists of a dry spherical cavity placed into the graphite thermal column of the SSR core and the intermediate energy neutron irradiation facility is a {sigma}{sigma} system located into the thermal flux cavity. The implementation of the irradiation facilities into the under-water thermal column represented an important challenge from the standpoint of instrumentation solutions. The neutron flux and spectrum measurements were performed using foil activation techniques and fission rate measurements by sealed fission chambers, followed by spectrum unfolding procedure. The absolute fission reaction measurements, using calibrated fission chambers, allow the neutron flux density unit transfer from international reference neutron fields. The MCNP-4C code package was used for neutron spectrum computations in the thermal flux cavity and in the {sigma}{sigma} system. The neutron characterization program demonstrates the accuracy of the spectrum characteristics and neutron flux densities reported to the local monitoring system count rates. Some discrepancies, as compared to other similar facilities, were identified and discussed. These are caused by thermal column particularities: the presence of a water layer between the graphite cells (thermal neutron absorption) and smaller geometrical dimensions (neutron escape phenomena). Based on these results the metrological certification process, according to Romanian metrological laws requirements, is now in progress. (nevyjel)

  15. An investigation of high-temperature irradiation test program of new ceramic materials

    International Nuclear Information System (INIS)

    Ishino, Shiori; Terai, Takayuki; Oku, Tatsuo

    1999-08-01

    The Japan Atomic Energy Research Institute entrusted the Atomic Energy Society of Japan with an investigation into the trend of irradiation processing/damage research on new ceramic materials. The present report describes the result of the investigation, which was aimed at effective execution of irradiation programs using the High Temperature Engineering Test Reactor (HTTR) by examining preferential research subjects and their concrete research methods. Objects of the investigation were currently on-going preliminary tests of functional materials (high-temperature oxide superconductor and high-temperature semiconductor) and structural materials (carbon/carbon and SiC/SiC composite materials), together with newly proposed subjects of, e.g., radiation effects on ceramics-coated materials and super-plastic ceramic materials as well as microscopic computer simulation of deformation and fracture of ceramics. These works have revealed 1) the background of each research subject, 2) its objective and significance from viewpoints of science and engineering, 3) research methodology in stages from preliminary tests to real HTTR irradiation, and 4) concrete HTTR-irradiation methods which include main specifications of test specimens, irradiation facilities and post-irradiation examination facilities and apparatuses. The present efforts have constructed the important fundamentals in the new ceramic materials field for further planning and execution of the innovative basic research on high-temperature engineering. (author)

  16. Quality engineering in FFTF irradiation tests

    International Nuclear Information System (INIS)

    Caplinger, W.H.

    1980-01-01

    The design and fabrication of an irradiation test for the Fast Flux Test Facility are planned, controlled and documented in accordance with the Department of Energy standards. Tests built by Westinghouse Hanford Company are further controlled and guided by a series of increasingly specific documents, including guidelines for program control, procedures for engineering operations, standard practices and detailed operating procedures. In response to this guidance, a series of five documents is prepared covering each step of the experiment from conception through fabrication and assembly. This paper describes the quality assurance accompanying these five steps

  17. Advanced Test Reactor National Scientific User Facility

    International Nuclear Information System (INIS)

    Marshall, Frances M.; Benson, Jeff; Thelen, Mary Catherine

    2011-01-01

    The Advanced Test Reactor (ATR), at the Idaho National Laboratory (INL), is a large test reactor for providing the capability for studying the effects of intense neutron and gamma radiation on reactor materials and fuels. The ATR is a pressurized, light-water, high flux test reactor with a maximum operating power of 250 MWth. The INL also has several hot cells and other laboratories in which irradiated material can be examined to study material irradiation effects. In 2007 the US Department of Energy (DOE) designated the ATR as a National Scientific User Facility (NSUF) to facilitate greater access to the ATR and the associated INL laboratories for material testing research by a broader user community. This paper highlights the ATR NSUF research program and the associated educational initiatives.

  18. Advanced Test Reactor National Scientific User Facility

    Energy Technology Data Exchange (ETDEWEB)

    Frances M. Marshall; Jeff Benson; Mary Catherine Thelen

    2011-08-01

    The Advanced Test Reactor (ATR), at the Idaho National Laboratory (INL), is a large test reactor for providing the capability for studying the effects of intense neutron and gamma radiation on reactor materials and fuels. The ATR is a pressurized, light-water, high flux test reactor with a maximum operating power of 250 MWth. The INL also has several hot cells and other laboratories in which irradiated material can be examined to study material irradiation effects. In 2007 the US Department of Energy (DOE) designated the ATR as a National Scientific User Facility (NSUF) to facilitate greater access to the ATR and the associated INL laboratories for material testing research by a broader user community. This paper highlights the ATR NSUF research program and the associated educational initiatives.

  19. The BLAIRR Irradiation Facility Hybrid Spallation Target Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Simos N.; Hanson A.; Brown, D.; Elbakhshawn, M.

    2016-04-11

    BLAIRR STUDY STATUS OVERVIEW Beamline Complex Evaluation/Assessment and Adaptation to the Goals Facility Radiological Constraints ? Large scale analyses of conventional facility and integrated shield (concrete, soil)Target Optimization and Design: Beam-target interaction optimization Hadronic interaction and energy deposition limitations Single phase and Hybrid target concepts Irradiation Damage Thermo-mechanical considerations Spallation neutron fluence optimization for (a) fast neutron irradiation damage (b) moderator/reflector studies, (c) NTOF potential and optimization (d) mono-energetic neutron beam

  20. Positive ion irradiation facility

    International Nuclear Information System (INIS)

    Braby, L.A.

    1985-01-01

    Many questions about the mechanisms of the response of cells to ionizing radiation can best be investigated using monoenergetic heavy charged particle beams. Questions of the role of different types of damage in the LET effect, for example, are being answered by comparing repair kinetics for damage induced by electrons with that produced by helium ions. However, as the models become more sophicated, the differences between models can be detected only with more precise measurements, or by combining high- and low-LET irradiations in split-dose experiments. The design of the authors present cell irradiation beam line has limited the authors to irradiating cells in a partial vacuum. A new way to mount the dishes and bring the beam to the cells was required. Several means of irradiating cells in mylar-bottom dishes have been used at other laboratories. For example at the RARAF Facility, the dual ion experiments are done with the dish bottom serving as the beam exit window but the cells are in a partial vacuum to prevent breaking the window. These researchers have chosen instead to use the dish bottom as the beam window and to irradiate the entire dish in a single exposure. A special, very fast pumping system will be installed at the end of the beam line. This system will make it possible to irradiate cells within two minutes of installing them in the irradiation chamber. In this way, the interaction of electron and ion-induced damage in Chlamydomonas can be studied with time between doses as short as 5 minutes

  1. Development of a quality system for a contract irradiation facility

    International Nuclear Information System (INIS)

    Siyakus, G.

    2002-01-01

    The use of Industrial Irradiation Systems, in order to process medical supplies and food commodities, has almost 50 years experiences in the world. The food irradiation process has been approved by more than 40 countries around the world and it has been endorsed or supported by numerous national and international organizations and professional groups. Today, radiation sterilization of medical supplies is the most preferred technology in almost every developed country. Other applications: such as waste and flue gas treatment, polymer processing are also put into practice in wider range than before. Higher capital cost compared to the operation cost, the nature of continuous decay of the radiation sources used to obtain gamma rays, obligate the owners of gamma facilities to operate systems based on the 24 hours a day and 7 days per week. On the other hand, higher throughput capacity and economical brake point for profitability, force irradiation companies to offer service for the varied products of the companies. Industrial irradiation facilities providing services for varied companies by irradiating different kind of commodities so called contract irradiator or multipurpose irradiator and most of the irradiation facilities, particularly gamma irradiators running in different locations of the World, operates as contract irradiators. The radiation facilities are considered as a part of the manufacturing process, and must conform to the pertinent general Code of Good Manufacturing Practice (GMP) which has been declared by the principal producer. Customers of these facilities may have petitions, such as irradiation temperature, dose rate, minimal and maximal doses; storage conditions before and after irradiation. Design parameters related to the dose rate, product size, density and weight, irradiation and storage temperatures are the main limitations. Varied process conditions can be easily applied in the laboratory may set forth difficulties in industrial processes

  2. SP-100 Fuel Pin Performance: Results from Irradiation Testing

    Science.gov (United States)

    Makenas, Bruce J.; Paxton, Dean M.; Vaidyanathan, Swaminathan; Marietta, Martin; Hoth, Carl W.

    1994-07-01

    A total of 86 experimental fuel pins with various fuel, liner, and cladding candidate materials have been irradiated in the Experimental Breeder Reactor-II (EBR-II) and the Fast Flux Test Facility (FFTF) reactor as part of the SP-100 fuel pin irradiation testing program. Postirradiation examination results from these fuel pins are key in establishing performance correlations and demonstrating the lifetime and safety of the reactor fuel system. This paper provides a brief description of the in-reactor fuel pin tests and presents the most recent irradiation data on the performance of wrought rhenium (Re) liner material and high density UN fuel at goal burnup of 6 atom percent (at. %). It also provides an overview of the significant variety of other fuel/liner/cladding combinations which were irradiated as part of this program and which may be of interest to more advanced efforts.

  3. ITER primary cryopump test facility

    International Nuclear Information System (INIS)

    Petersohn, N.; Mack, A.; Boissin, J.C.; Murdoc, D.

    1998-01-01

    A cryopump as ITER primary vacuum pump is being developed at FZK under the European fusion technology programme. The ITER vacuum system comprises of 16 cryopumps operating in a cyclic mode which fulfills the vacuum requirements in all ITER operation modes. Prior to the construction of a prototype cryopump, the concept is tested on a reduced scale model pump. To test the model pump, the TIMO facility is being built at FZK in which the model pump operation under ITER environmental conditions, except for tritium exposure, neutron irradiation and magnetic fields, can be simulated. The TIMO facility mainly consists of a test vessel for ITER divertor duct simulation, a 600 W refrigerator system supplying helium in the 5 K stage and a 30 kW helium supply system for the 80 K stage. The model pump test programme will be performed with regard to the pumping performance and cryogenic operation of the pump. The results of the model pump testing will lead to the design of the full scale ITER cryopump. (orig.)

  4. IRRAD: The New 24GeV/c Proton Irradiation Facility at CERN

    CERN Document Server

    Gkotse, Blerina; Moll, Michael; Ravotti, Federico

    2016-01-01

    The proton and mixed-field irradiation facilities at the CERN PS East Area (known as IRRAD1 and IRRAD2), have been heavily exploited for irradiation of particle detectors, electronic components and materials since 1992. With the increasing demand of irradiation experiments, and in view of the High-Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC), these facilities suffered of a number of unpleasant restrictions such as the space availability, the maximum achievable particle flux and several access constraints. In the framework of the AIDA project, an upgrade of these facilities was carried out during the Long Shutdown 1 (LS1) of the CERN accelerator complex. The new combined East Area IRRADiation facility (EA-IRRAD) started the commissioning in October 2014. While the new proton facility (IRRAD) continue to be mainly devoted to the radiation hardness studies for the High Energy Physics community, the new mixed-field facility (CHARM) mainly hosts irradiation experiments for the validation of electr...

  5. HiRadMat: A high‐energy, pulsed beam, material irradiation facility

    CERN Multimedia

    Charitonidis, Nikolaos

    2016-01-01

    HiRadMat is a facility constructed in 2011, designed to provide high-intensity pulsed beams to an irradiation area where different material samples or accelerator components can be tested. The facility, located at the CERN SPS accelerator complex, uses a 440 GeV proton beam with a pulse length up to 7.2 μs and a maximum intensity up to 1E13 protons / pulse. The facility, a unique place for performing state-of-the art beam-to-material experiments, operates under transnational access and welcomes and financially supports, under certain conditions, experimental teams to perform their experiments.

  6. Currently developing opportunities in food irradiation and modern irradiation facilities

    International Nuclear Information System (INIS)

    Wanke, R.

    1997-01-01

    I. Factor currently influencing advancing opportunities for food irradiation include: heightened incidence and awareness of food borne illnesses and causes. Concerns about ensuring food safety in international as well as domestic trade. Regulatory actions regarding commonly used fumigants/pesticides e.g. Me Br. II. Modern irradiator design: the SteriGenics M ini Cell . A new design for new opportunities. Faster installation of facility. Operationally and space efficient. Provides local o nsite control . Red meat: a currently developing opportunity. (Author)

  7. Irradiation testing of miniature fuel plates for the RERTR program

    Energy Technology Data Exchange (ETDEWEB)

    Senn, R L; Martin, M M [Oak Ridge National Laboratory, Oak Ridge, TN 37830 (United States)

    1983-08-01

    An irradiation test facility, which provides a test bed for irradiating a variety of miniature fuel plates miniplates) for the Reduced Enrichment Research and Test Reactors (RERTR) program, has been placed into operation. The objective of these tests is to screen various candidate fuel materials as to their suitability for replacing the highly enriched uranium fuel materials currently used by the world's test and research reactors with a lower enrichment fuel material, without significantly degrading reactor operating characteristics and power levels. The use of low uranium enrichment of about 20% {sup 235}U in place of highly enriched fuel for these reactors would reduce the potential for {sup 235}U diversion. Fuel materials currently being evaluated in this first phase of these screening tests include aluminum-base dispersion-type fuel plates with fuel cores of 1) high uranium content U{sup 3}){sup 8}-Al being developed by ORNL, 2) high uranium content UAI{sub x}-Al being developed by EG and G Idaho, Inc., and 3) very high uranium content U{sub 3}Si-Al- being developed by ANL. The miniplates are 115-mm long by 50-mm wide with overall plate thicknesses of 1.27 or 1.52 mm. The fuel core dimensions vary according to overall plate thicknesses with a minimal clad thickness requirement of 0.20 mm. Sixty such miniplates (thirty of each thickness) can be irradiated in one test facility. The irradiation test facility, designated as HFED-1 is operating in core position E-7 in the Oak Ridge Research Reactor (ORR), a 30-MW water-moderated reactor. The peak neutron flux measured for this experiment is 1.96 x 10{sup 18} neutrons m{sub -2} s{sub -1}. The various types of miniplates will achieve burnups of up to approximately 2.2x10{sup 27} fissions/m{sup 3} of fuel, which will require approximately eight full power months of irradiation. During reactor shutdown periods, the experiment is removed from the reactor, moved to a special poolside station, disassembled, and inspected

  8. Neutron-irradiation facilities at the Intense Pulsed Neutron Source-I for fusion magnet materials studies

    International Nuclear Information System (INIS)

    Brown, B.S.; Blewitt, T.H.

    1982-01-01

    The decommissioning of reactor-based neutron sources in the USA has led to the development of a new generation of neutron sources that employ high-energy accelerators. Among the accelerator-based neutron sources presently in operation, the highest-flux source is the Intense Pulsed Neutron Source (IPNS), a user facility at Argonne National Laboratory. Neutrons in this source are produced by the interaction of 400 to 500 MeV protons with either of two 238 U target systems. In the Radiation Effects Facility (REF), the 238 U target is surrounded by Pb for neutron generatjion and reflection. The REF has three separate irradiation thimbles. Two thimbles provide irradiation temperatures between that of liquid He and several hundred degrees centigrade. The third thimble operates at ambient temperature. The large irradiation volume, the neutron spectrum and flux, the ability to transfer samples without warm up, and the dedication of the facilities during the irradiation make this ideally suited for radiation damage studies on components for superconducting fusion magnets. Possible experiments for fusion magnet materials are discussed on cyclic irradiation and annealing of stabilizers in a high magnetic field, mechanical tests on organic insulation irradiated at 4 K, and superconductors measured in high fields after irradiation

  9. Postirradiation examination results for the Irradiation Effects Scoping Test 2

    International Nuclear Information System (INIS)

    Mehner, A.S.

    1977-01-01

    The postirradiation examination results are reported for two rods from the second scoping test (IE-ST-2) of the Nuclear Regulatory Commission Irradiation Effects Program. The rods were irradiated in the in-pile test loop of the Power Burst Facility at the Idaho National Engineering Laboratory. Rod IE-005 was fabricated from fresh fuel and cladding previously irradiated in the Saxton Reactor. Rod IE-006, fabricated from fresh fuel and unirradiated cladding, was equipped with six developmental cladding surface thermocouples. The rods were preconditioned, power ramped, and then subjected to film boiling operation. The performance of the rods and the developmental thermocouples are evaluated from the post irradiation examination results. The effects of prior irradiation damage in cladding are discussed in relation to fuel rod behavior during a power ramp and subsequent film boiling operation

  10. Facilities for studying radiation damage in nonmetals during irradiation

    International Nuclear Information System (INIS)

    Levy, P.W.

    1984-08-01

    Two facilities have been developed for making optical absorption, luminescence and other measurements on a single sample before, during and after irradiation. One facility uses 60 Co gamma rays and the other 0.5 to 3 MeV electrons from an accelerator. Optical relays function as spectrophotometers, luminescenc detectors, etc. All radiation sensitive components are outside of walk-in irradiation chambers; all measurement control and data recording is computerized. Irradiations are made at controlled temperatures between 5K and 900 0 C. The materials studied include glasses, quartz, alkali halides (especially natural rock salt), organic crystals, etc. As determined from color center measurements the damage formation rate in all materials studied at 25 0 C or above is strongly temperature dependent. The defect concentration during irradiation is usually much greater than that measured after irradiation. The fraction of defects annealing after irradiation and the annealing rate usually increases as the irradiation temperature increases. The completed studies demonstrate that, in most cases, the extent of maximum damage and the damage formation and annealing kinetics can be determined only by making measurements during irradiation

  11. Cold moderator test facilities working group

    International Nuclear Information System (INIS)

    Bauer, Guenter S.; Lucas, A. T.

    1997-09-01

    The working group meeting was chaired by Bauer and Lucas.Testing is a vital part of any cold source development project. This applies to specific physics concept verification, benchmarking in conjunction with computer modeling and engineering testing to confirm the functional viability of a proposed system. Irradiation testing of materials will always be needed to continuously extend a comprehensive and reliable information database. An ever increasing worldwide effort to enhance the performance of reactor and accelerator based neutron sources, coupled with the complexity and rising cost of building new generation facilities, gives a new dimension to cold source development and testing programs. A stronger focus is now being placed on the fine-tuning of cold source design to maximize its effectiveness in fully exploiting the facility. In this context, pulsed spallation neutron sources pose an extra challenge due to requirements regarding pulse width and shape which result from a large variety of different instrument concepts. The working group reviewed these requirements in terms of their consequences on the needs for testing equipment and compiled a list of existing and proposed facilities suitable to carry out the necessary development work.

  12. Accelerated radiation damage test facility using a 5 MV tandem ion accelerator

    Science.gov (United States)

    Wady, P. T.; Draude, A.; Shubeita, S. M.; Smith, A. D.; Mason, N.; Pimblott, S. M.; Jimenez-Melero, E.

    2016-01-01

    We have developed a new irradiation facility that allows to perform accelerated damage tests of nuclear reactor materials at temperatures up to 400 °C using the intense proton (spectrum of potential radio-active nuclides produced during the sample irradiation. The beam line capabilities have been tested by irradiating a 20Cr-25Ni-Nb stabilised stainless steel with a 3 MeV proton beam to a dose level of 3 dpa. The irradiation temperature was 356 °C, with a maximum range in temperature values of ±6 °C within the first 24 h of continuous irradiation. The sample stage is connected to ground through an electrometer to measure accurately the charge deposited on the sample. The charge can be integrated in hardware during irradiation, and this methodology removes uncertainties due to fluctuations in beam current. The measured gamma spectrum allowed the identification of the main radioactive nuclides produced during the proton bombardment from the lifetimes and gamma emissions. This dedicated radiation damage beam line is hosted by the Dalton Cumbrian Facility of the University of Manchester.

  13. The Hydraulic Test Procedure for Non-instrumented Irradiation Test Rig of Annular Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan; Park, Chan Kook

    2008-08-15

    This report presents the procedure of pressure drop test, vibration test and endurance test for the non-instrumented rig using the irradiation test in HANARO of advanced PWR annular fuel which were designed and fabricated by KAERI. From the out-pile thermal hydraulic tests, confirm the flow rate at the 200 kPa pressure drop and measure the RMS displacement at this time. And the endurance test is confirmed the wear and the integrity of the non-instrumented rig at the 110% design flow rate. This out-pile test perform the Flow-Induced Vibration and Pressure Drop Experimental Tester(FIVPET) facility. The instruments in FIVPET facility was calibrated in KAERI and the pump and the thermocouple were certified by manufacturer.

  14. Ten years operating experience at the Fast Flux Test Facility: A decade of excellence

    International Nuclear Information System (INIS)

    Swaim, D.J.; Waldo, J.B.; Farabee, O.A.

    1991-07-01

    The Fast Flux Test Facility is a 400 MW(t) fast reactor cooled by three sodium loops. The Fast Flux Test Facility is managed by the Westinghouse Hanford Company for the US Department of Energy. The Fast Flux Test Facility was designed and constructed to provide irradiation testing of fuels and materials for the US Department of Energy Liquid Metal Reactor research program. Facility activities have increased to include fusion power materials testing, passive safety testing, isotope production, and international collaboration. 5 figs

  15. Currently developing opportunities in food irradiation and modern irradiation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, R [Director Business Development. SteriGenics International Inc. 17901 East Warren Avenue No. 4, Detroit, Michigan 48224-1333 (United States)

    1998-12-31

    I. Factor currently influencing advancing opportunities for food irradiation include: heightened incidence and awareness of food borne illnesses and causes. Concerns about ensuring food safety in international as well as domestic trade. Regulatory actions regarding commonly used fumigants/pesticides e.g. Me Br. II. Modern irradiator design: the SteriGenics {sup M}ini Cell{sup .} A new design for new opportunities. Faster installation of facility. Operationally and space efficient. Provides local {sup o}nsite control{sup .} Red meat: a currently developing opportunity. (Author)

  16. Currently developing opportunities in food irradiation and modern irradiation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, R. [Director Business Development. SteriGenics International Inc. 17901 East Warren Avenue No. 4, Detroit, Michigan 48224-1333 (United States)

    1997-12-31

    I. Factor currently influencing advancing opportunities for food irradiation include: heightened incidence and awareness of food borne illnesses and causes. Concerns about ensuring food safety in international as well as domestic trade. Regulatory actions regarding commonly used fumigants/pesticides e.g. Me Br. II. Modern irradiator design: the SteriGenics {sup M}ini Cell{sup .} A new design for new opportunities. Faster installation of facility. Operationally and space efficient. Provides local {sup o}nsite control{sup .} Red meat: a currently developing opportunity. (Author)

  17. Low Current Irradiation Facility at KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Min, Yi-Sub; Park, Sung-Kyun; Park, Jeong-Min; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Korea Multi-purpose Accelerator Complex (KOMAC) is branched off from Korea Atomic Energy Research Institute (KAERI). The 100 MeV linear proton accelerator as well as the various types of the ion accelerator have been operated and developed in KOMAC. The operation of these accelerators included in the KOMAC site should be approved by Nuclear Safety and Security Committee (NSSC). To aims at the operation in 2017, a research facility to irradiate low current beam has been prepared. The radiation safety analysis was performed again to adopt with the change. As a result of these changes, an easy access into the facility will be got to. This paper introduces the activity in terms of the radiation safety for these accelerator operations. Radiation analysis was performed depending on the planned changes, and it was confirmed that there is no effect by the changes. This facility is expected to be made the best use at a field which could be irradiated with proton beam which has an energy up to 100 MeV and current up to 10 nA.

  18. PIREX II, a new irradiation facility for testing fusion first wall materials

    International Nuclear Information System (INIS)

    Marmy, P.; Daum, M.; Gavillet, D.; Green, S.; Green, W.V.; Hegedues, F.; Pronnecke, S.; Rohrer, U.; Stiefel, U.; Victoria, M.

    1988-12-01

    A new irradiation facility, PIREX II, became operational in March 1987. It is located on a dedicated beam line split from the main beam of the 590 MeV proton accelerator at the Paul Scherrer Institute (PSI). Irradiation with protons of this energy introduces simultaneously displacement damage, helium and other impurities. Because of the penetration range of 590 MeV protons, both damage and impurities are homogeneously distributed in the target. The installation has its own beam line optics that can support a proton current of up to 50 μA. At a typical beam density of 4 μA/mm 2 , the damage rate in steels is 0.7 x 10 -5 dpa/sec (dpa: displacements per atom) and the helium production rate is 170 appm He/dpa. Both flat tensile specimens of up to 0.4 mm thickness and tubular fatigue samples of 3 mm diameter can be irradiated. Cooling of the temperatures can be controlled between 100 o and 800 o C. Installation of an in situ low cycle fatigue device is foreseen. Beams of up to 20 μA have been obtained, the beam having approximately a gaussian distribution of elliptical cross section with 4 σ between 0.8 and 3 mm by 10 mm. Irradiations for a dosimetry program have been completed on samples of Al, Cu, Fe, Ni, Au, W, and the 1.4914 ferritic steel. The evaluation of results allows the correct choice of reactions to be used for determining total dose, from the standpoint of half life and gamma energy. A program of irradiations on candidate materials for the Next European Torus (NET) design (Cu and Cu alloys, the 1.4914 ferritic martensitic steel, W and W-Re alloys and Mo alloys), where the above mentioned characteristics of this type of irradiation can be used advantageously, is now under way. (author) 11 figs., 4 tabs., 20 refs

  19. Irradiation facilitates at the advanced test reactor

    International Nuclear Information System (INIS)

    Grover, Blaine S.

    2006-01-01

    The Advanced Test Reactor (ATR) is the third generation and largest test reactor built in the Reactor Technology Complex (RTC - formerly known as the Test Reactor Area), located at the Idaho National Laboratory (INL), to study the effects of intense neutron and gamma radiation on reactor materials and fuels. The RTC was established in the early 1950's with the development of the Materials Testing Reactor (MTR), which operated until 1970. The second major reactor was the Engineering Test Reactor (ETR), which operated from 1957 to 1981, and finally the ATR, which began operation in 1967 and will continue operation well into the future. These reactors have produced a significant portion of the world's data on materials response to reactor environments. The wide range of experiment facilities in the ATR and the unique ability to vary the neutron flux in different areas of the core allow numerous experiment conditions to co-exist during the same reactor operating cycle. Simple experiments may involve a non-instrumented capsule containing test specimens with no real-time monitoring or control capabilities. More sophisticated testing facilities include inert gas temperature control systems and pressurized water loops that have continuous chemistry, pressure, temperature, and flow control as well as numerous test specimen monitoring capabilities. There are also apparatus that allow for the simulation of reactor transients on test specimens. The paper has the following contents: ATR description and capabilities; ATR operations, quality and safety requirements; Static capsule experiments; Lead experiments; Irradiation test vehicle; In-pile loop experiments; Gas test loop; Future testing; Support facilities at RTC; Conclusions. To summarize, the ATR has a long history in fuel and material irradiations, and will be fulfilling a critical role in the future fuel and material testing necessary to develop the next generation reactor systems and advanced fuel cycles. The

  20. Development of the IFJ single ion hit facility for cells irradiation

    International Nuclear Information System (INIS)

    Veselov, O.; Polak, W.; Ugenskiene, R.; Hajduk, R.; Lebed, K.; Lekki, J.; Horwacik, T.; Dutkiewicz, E.M.; Maranda, S.; Pieprzyca, T.; Sarnecki, C.; Stachura, Z.; Szklarz, Z.; Styczen, J.

    2005-12-01

    In recent years a single ion hit facility (SIHF) has been constructed at the IFJ ion microprobe. The setup is used for the precise irradiations of living cells by a controlled number of ions. The facility allows investigations in various aspects of biomedical research, such as adaptive response, bystander effect, inverse dose-rate effect, low-dose hypersensitivity, etc. Those investigations have two very important requirements: (i) cells must be examined in their natural state and environment, i.e. without previously being killed, and preferentially, neither fixed nor stained, and (ii) a possibility of automatic irradiation of large number of cells with a computer recognition of their positions must be provided. This work presents some of the crucial features of the off-line and on-line optical systems, including self-developed software responsible for the automatic cell recognition. We also show several tests carried out to determine the efficiency of the whole setup and some segments. In conclusion, the results of our first irradiation measurements performed with living cells are demonstrated. (author)

  1. Innovations to increase throughput of the multipurpose irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Cabalfin, Estelita G; Lanuza, Luvimina G; Maningas, Aurelio L; Solomon, Haydee M [Irradiation Services Unit, Nuclear Services and Training Division, Philippine Nuclear Research Institute, Quezon City (Philippines)

    1998-07-01

    With the installation and operation of the PNRI [Philippine Nuclear Research Institute] multipurpose irradiation facility, several local industries are now aware of, and in fact using gamma radiation for sterilization or decontamination of medical and pharmaceutical products, packaging materials and for food preservation. However, the multipurpose irradiation facility has limited capacity and capability, since this was designed as a pilot scale irradiator for research and development. To meet the increasing demand of gamma irradiation service, a new product handling system was locally designed, fabricated and installed. Performance, in terms of total loading and more importantly, radiation dose distribution of the new product handling system, was evaluated. An increase in product throughput was realized effectively with the new product handling system. (Author)

  2. Innovations to increase throughput of the multipurpose irradiation facility

    International Nuclear Information System (INIS)

    Cabalfin, Estelita G.; Lanuza, Luvimina G.; Maningas, Aurelio L.; Solomon, Haydee M.

    1998-01-01

    With the installation and operation of the PNRI [Philippine Nuclear Research Institute] multipurpose irradiation facility, several local industries are now aware of, and in fact using gamma radiation for sterilization or decontamination of medical and pharmaceutical products, packaging materials and for food preservation. However, the multipurpose irradiation facility has limited capacity and capability, since this was designed as a pilot scale irradiator for research and development. To meet the increasing demand of gamma irradiation service, a new product handling system was locally designed, fabricated and installed. Performance, in terms of total loading and more importantly, radiation dose distribution of the new product handling system, was evaluated. An increase in product throughput was realized effectively with the new product handling system. (Author)

  3. Irradiation Facilities of the Takasaki Advanced Radiation Research Institute

    Directory of Open Access Journals (Sweden)

    Satoshi Kurashima

    2017-03-01

    Full Text Available The ion beam facility at the Takasaki Advanced Radiation Research Institute, the National Institutes for Quantum and Radiological Science and Technology, consists of a cyclotron and three electrostatic accelerators, and they are dedicated to studies of materials science and bio-technology. The paper reviews this unique accelerator complex in detail from the viewpoint of its configuration, accelerator specification, typical accelerator, or irradiation technologies and ion beam applications. The institute has also irradiation facilities for electron beams and 60Co gamma-rays and has been leading research and development of radiation chemistry for industrial applications in Japan with the facilities since its establishment. The configuration and utilization of those facilities are outlined as well.

  4. IFMIF (International Fusion Materials Irradiation Facility) key element technology phase interim report

    International Nuclear Information System (INIS)

    Nakamura, Hiroo; Ida, Mizuho; Sugimoto, Masayoshi; Takeuchi, Hiroshi; Yutani, Toshiaki

    2002-03-01

    Activities of International Fusion Materials Irradiation Facility (IFMIF) have been performed under an IEA collaboration since 1995. IFMIF is an accelerator-based deuteron (D + )-lithium (Li) neutron source designed to produce an intense neutron field (2 MW/m 2 , 20 dpa/year for Fe) in a volume of 500 cm 3 for testing candidate fusion materials. In 2000, a 3 year Key Element technology Phase (KEP) of IFMIF was started to reduce the key technology risk factors. This interim report summarizes the KEP activities until mid 2001 in the major project work-breakdown areas of accelerator, target, test facilities and design integration. (author)

  5. Flux and energy deposition distribution studies inside the irradiation room of the portuguese 60Co irradiation facility

    International Nuclear Information System (INIS)

    Portugal, Luis; Oliveira, Carlos

    2008-01-01

    Full text: In December 2003 the irradiator of the Portuguese 60 Co irradiation facility, UTR, was replenished. Eighteen new sources were loaded and the older ones (156) were rearranged. The result was an irradiator with about 10.2 P Bq of total activity. The active area of the irradiator has also increased. Now it uses twenty five of the thirty tubes of the source rack, nine more than in the previous geometry. This facility was designed mainly for sterilisation of medical devices. However it is also used for the irradiation of other products such as cork stoppers, plastics and a limited number of food and feed. The purpose of this work is to perform dosimetric studies inside the irradiation room of a 60 Co irradiation facility, particularly, the flux and energy deposition distributions. The MCNPX code was used for the simulation of the facility. The track average mesh tally capabilities of MCNPX were used to plot the photon flux and energy deposition distributions. This tool provides a fast way for flux and energy deposition mapping. The absorbed dose distribution near the walls of the irradiation room was also calculated. Instead of using meshtallys as before, the average absorbed dose inside boxes lined with the walls was determined and afterwards a plot of its distribution was made. The absorbed dose rates obtained ranged from 5 to 500 Gy.h -1 depending on material being irradiated in process and the location on the wall. These positions can be useful for fixed irradiation purposes. Both dosimetric studies were done considering two different materials being irradiated in the process: cork stoppers and water, materials with quite different densities (0.102 and 1 g.cm-3, respectively). These studies showed some important characteristics of the radiation fields inside the irradiation room, namely its spatial heterogeneity. Tunnelling and shadow effects were enhanced when the product boxes increases its density. Besides a deeper dosimetric understanding of the

  6. Cobalt 60 commercial irradiation facilities

    International Nuclear Information System (INIS)

    West, G.

    1985-01-01

    The advantage of using cobalt 60 for ionizing treatment is that it has excellent penetration. Gamma plants are also very efficient, in as much as there is very little mechanical or electrical equipment in a gamma irradiation facility. The average efficiency of a gamma plant is usually around 95% of all available processing time

  7. Programmed temperature control of capsule in irradiation test with personal computer at JMTR

    International Nuclear Information System (INIS)

    Saito, H.; Uramoto, T.; Fukushima, M.; Obata, M.; Suzuki, S.; Nakazaki, C.; Tanaka, I.

    1992-01-01

    The capsule irradiation facility is one of various equipments employed at the Japan Materials Testing Reactor (JMTR). The capsule facility has been used in irradiation tests of both nuclear fuels and materials. The capsule to be irradiated consists of the specimen, the outer tube and inner tube with a annular space between them. The temperature of the specimen is controlled by varying the degree of pressure (below the atmospheric pressure) of He gas in the annular space (vacuum-controlled). Beside this, in another system the temperature of the specimen is controlled with electric heaters mounted around the specimen (heater-controlled). The use of personal computer in the capsule facility has led to the development of a versatile temperature control system at the JMTR. Features of this newly-developed temperature control system lie in the following: the temperature control mode for a operation period can be preset prior to the operation; and the vacuum-controlled irradiation facility can be used in cooperation with the heater-controlled. The introduction of personal computer has brought in automatic heat-up and cool-down operations of the capsule, setting aside the hand-operated jobs which had been conducted by the operators. As a result of this, the various requirements seeking a higher accuracy and efficiency in the irradiation can be met by fully exploiting the capabilities incorporated into the facility which allow the cyclic or delicate changes in the temperature. This paper deals with a capsule temperature control system with personal computer. (author)

  8. Design and Testing for a New Thermosyphon Irradiation Vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Felde, David K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Carbajo, Juan J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McDuffee, Joel Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL) requires most materials and all fuel experiments to be placed in a pressure containment vessel to ensure that internal contaminants such as fission products cannot be released into the primary coolant. It also requires that all experiments be capable of withstanding various accident conditions (e.g., loss of coolant) without generating vapor bubbles on the surface of the experiment in the primary coolant. These requirements are intended to artificially increase experiment temperatures by introducing a barrier between the experimental materials and the HFIR coolant, and by reducing heat loads to the HFIR primary coolant, thus ensuring that no boiling can occur. A proposed design for materials irradiation would remove these limitations by providing the required primary containment with an internal cooling flow. This would allow for experiments to be irradiated without concern for coolant contamination (e.g., from cladding failure of advanced fuel pins) or for specimen heat load. This report describes a new materials irradiation experiment design that uses a thermosyphon cooling system to allow experimental materials direct access to a liquid coolant. The new design also increases the range of conditions that can be tested in HFIR. This design will provide a unique capability to validate the performance of current and advanced fuels and materials. Because of limited supporting data for this kind of irradiation vehicle, a test program was initiated to obtain operating data that can be used to (1) qualify the vehicle for operation in HFIR and (2) validate computer models used to perform design- and safety-basis calculations. This report also describes the test facility and experimental data, and it provides a comparison of the experimental data to computer simulations. A total of 51 tests have been completed: four tests with pure steam, 12 tests with argon, and 35 tests with helium. A total

  9. Construction plan of ion irradiation facility in JAERI

    International Nuclear Information System (INIS)

    Tanaka, Ryuichi

    1987-01-01

    The Takasaki Radiation Chemistry Research Establishment of Japan Atomic Energy Research Institute (JAERI) started the construction of an ion irradiation facility to apply ion beam to the research and development of radiation resistant materials for severe environment, the research on biotechnology and new functional materials. This project was planned as ion beam irradiation becomes an effective means for the research on fundamental physics and advanced technology, and the national guideline recently emphasizes the basic and pioneering field in research and development. This facility comprises an AVF cyclotron with an ECR ion source (maximum proton energy: 90 MeV), a 3 MV tandem accelerator, a 3 MV single end type Van de Graaf accelerator and a 400 kV ion implanter. In this report, the present status of planning the accelerators and the facility to be constructed, the outline of research plan, the features of the accelerators, and the beam characteristics are described. In this project, the research items are divided into the materials for space environment, the materials for nuclear fusion reactors, biotechnology, new functional materials, and ion beam technology. The ion beams required for the facility are microbeam, pulsed beam, multiple beam, neutron beam and an expanded irradiation field. (Kako, I.)

  10. Automatically controlled facilities for irradiation of silicon crystals at the Rossendorf Research Reactor

    International Nuclear Information System (INIS)

    Ross, R.

    1988-01-01

    This report describes the facilities for neutron transmutation doping of silicon in GDR. The irradiation of silicon single crystals began at Rossendorf in 1978 with simple equipment. Only a small amount of silicon could be irradiated in it. The fast increasing need of NTD-silicon made it necessary to design and construct new and better facilities. The new facilities are capable of irradiating silicon from 2'' to 3'' in diameter. The irradiation process takes place automatically with the assistance of a computer. Material produced has an axial homogeneity of ± 7%. Irradiation riggs, techniques, irradiation control and quality control are discussed. (author). 4 figs

  11. Updated Results of Ultrasonic Transducer Irradiation Test

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua; Palmer, Joe [Idaho National Laboratory, P.O. Box 1625, MS 4112, Idaho Falls, ID, 38415-3840 (United States); Ramuhalli, Pradeep; Keller, Paul; Montgomery, Robert [Pacific Northwest National Laboratory, 902 Battelle Blvd. Richland, WA, 99354 (United States); Chien, Hual-Te [Argonne National Laboratory, 9700 S. Cass Avenue Argonne, IL, 60439 (United States); Tittmann, Bernhard; Reinhardt, Brian [Pennsylvania State University, 212 Earth and Engr. Sciences Building, University Park, PA, 16802 (United States); Kohse, Gordon [Massachusetts Institute of Technology, 77 Massachusetts Ave. Cambridge, MA 02139 (United States); Rempe, Joy [Rempe and Associates, LLC, 360 Stillwater, Idaho Falls, ID 83404 (United States); Villard, J.F. [Commissariat a l' energie atomique et aux energies alternatives, Centre d' etudes de Cadarache, 13108 Saint-Paul-lez-Durance (France)

    2015-07-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10{sup 21} n/cm{sup 2}. A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET-ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation. (authors)

  12. Irradiation tests of readout chain components of the ATLAS liquid argon calorimeters

    International Nuclear Information System (INIS)

    Leroy, C.; Cheplakov, A.; Golikov, V.; Golubykh, S.; Kukhtin, V.; Kulagin, E.; Lushchikov, V.; Minashkin, V.; Shalyugin, A.

    2000-01-01

    Various readout chain components of the ATLAS liquid argon calorimeters have been exposed to high neutron fluences and γ doses at the irradiation test facility of the IBR-2 reactor of JINR, Dubna. Results of the capacitance and impedance measurements of coaxial cables are presented. Results of peeling tests of PC board samples (carton and copper strips) as a measure of the bonding agent irradiation hardness are also reported

  13. Irradiation tests of readout chain components of the ATLAS liquid argon calorimeters

    CERN Document Server

    Leroy, C; Golikov, V; Golubyh, S M; Kukhtin, V; Kulagin, E; Luschikov, V; Minashkin, V F; Shalyugin, A N

    1999-01-01

    Various readout chain components of the ATLAS liquid argon calorimeters have been exposed to high neutron fluences and $gamma$-doses at the irradiation test facility of the IBR-2 reactor of JINR, Dubna. Results of the capacitance and impedance measurements of coaxial cables are presented. Results of peeling tests of PC board samples (kapton and copper strips) as a measure of the bonding agent irradiation hardness are also reported.

  14. Lessons learned from accidents in industrial irradiation facilities

    International Nuclear Information System (INIS)

    1996-01-01

    Use of ionizing radiation in medicine, industry and research for technical development continues to increase throughout the world. One application with a high growth rate is irradiation suing high energy gamma photons and electron beams. There are currently more than 160 gamma irradiation facilities and over 600 electron beam facilities in operation in almost all IAEA Member States. The most common uses of these facilities are to sterilize medical and pharmaceutical products, to preserve foodstuffs, to synthesize polymers and to eradicate insects. Although this industry has a good safety record, there is a potential for accidents with serious consequences to human health because of the high dose rates produced by these sources. Fatal accidents have occurred at installations in both developed and developing countries. Such accidents have prompted a review of several accidents, including five with fatalities, by a team of manufacturers, regulatory authorities and operating organizations. Having looked closely at the circumstances of each accident and the apparent deficiencies in design, safety and regulatory systems and personnel performance, the team made a number of recommendations on the ways in which the safety of irradiators can be improved. The findings of extensive research pertaining to the lessons that can be learned from irradiator accidents are presented. This publication is intended for manufacturers, regulatory authorities and operating organizations dealing with industrial irradiators. It was drafted by J.E. Glen, United States Nuclear Regulatory Commission, United States of America, and P. Zuniga-Bello, Consejo Nacional de Ciencia y Technologia, Mexico

  15. IFMIF (International Fusion Materials Irradiation Facility) key element technology phase interim report

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Hiroo; Ida, Mizuho; Sugimoto, Masayoshi; Takeuchi, Hiroshi; Yutani, Toshiaki (eds.) [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-03-01

    Activities of International Fusion Materials Irradiation Facility (IFMIF) have been performed under an IEA collaboration since 1995. IFMIF is an accelerator-based deuteron (D{sup +})-lithium (Li) neutron source designed to produce an intense neutron field (2 MW/m{sup 2}, 20 dpa/year for Fe) in a volume of 500 cm{sup 3} for testing candidate fusion materials. In 2000, a 3 year Key Element technology Phase (KEP) of IFMIF was started to reduce the key technology risk factors. This interim report summarizes the KEP activities until mid 2001 in the major project work-breakdown areas of accelerator, target, test facilities and design integration. (author)

  16. MCNP Variance Reduction technique application for the Development Of the Citrusdal Irradiation Facility

    International Nuclear Information System (INIS)

    Makgae, R.

    2008-01-01

    A private company, Citrus Research International (CIR) is intending to construct an insect irradiation facility for the irradiation of insect for pest management in south western region of South Africa. The facility will employ a Co-60 cylindrical source in the chamber. An adequate thickness for the concrete shielding walls and the ability of the labyrinth leading to the irradiation chamber, to attenuate radiation to dose rates that are acceptably low, were determined. Two methods of MCNP variance reduction techniques were applied to accommodate the two pathways of deep penetration to evaluate the radiological impact outside the 150 cm concrete walls and steaming of gamma photons through the labyrinth. The point-kernel based MicroShield software was used in the deep penetration calculations for the walls around the source room to test its accuracy and the results obtained are in good agreement with about 15-20% difference. The dose rate mapping due to radiation Streaming along the labyrinth to the facility entrance is also to be validated with the Attila code, which is a deterministic code that solves the Discrete Ordinates approximation. This file provides a template for writing papers for the conference. (authors)

  17. MCNP Variance Reduction technique application for the Development Of the Citrusdal Irradiation Facility

    Energy Technology Data Exchange (ETDEWEB)

    Makgae, R. [Pebble Bed Modular Reactor (PBMR), P.O. Box 9396, Centurion (South Africa)

    2008-07-01

    A private company, Citrus Research International (CIR) is intending to construct an insect irradiation facility for the irradiation of insect for pest management in south western region of South Africa. The facility will employ a Co-60 cylindrical source in the chamber. An adequate thickness for the concrete shielding walls and the ability of the labyrinth leading to the irradiation chamber, to attenuate radiation to dose rates that are acceptably low, were determined. Two methods of MCNP variance reduction techniques were applied to accommodate the two pathways of deep penetration to evaluate the radiological impact outside the 150 cm concrete walls and steaming of gamma photons through the labyrinth. The point-kernel based MicroShield software was used in the deep penetration calculations for the walls around the source room to test its accuracy and the results obtained are in good agreement with about 15-20% difference. The dose rate mapping due to radiation Streaming along the labyrinth to the facility entrance is also to be validated with the Attila code, which is a deterministic code that solves the Discrete Ordinates approximation. This file provides a template for writing papers for the conference. (authors)

  18. Neutron irradiation facilities for fission and fusion reactor materials studies

    International Nuclear Information System (INIS)

    Rowcliffe, A.F.

    1985-01-01

    The successful development of energy-conversion machines based upon nuclear fission or fusion reactors is critically dependent upon the behavior of the engineering materials used to construct the full containment and primary heat extraction systems. The development of radiation damage-resistant materials requires irradiation testing facilities which reproduce, as closely as possible, the thermal and neutronic environment expected in a power-producing reactor. The Oak Ridge National Laboratory (ORNL) reference core design for the Center for Neutron Research (CNR) reactor provides for instrumented facilities in regions of both hard and mixed neutron spectra, with substantially higher fluxes than are currently available. The benefits of these new facilities to the development of radiation damage resistant materials are discussed in terms of the major US fission and fusion reactor programs

  19. Whole-Pin Furnace system: An experimental facility for studying irradiated fuel pin behavior under potential reactor accident conditions

    International Nuclear Information System (INIS)

    Liu, Y.Y.; Tsai, H.C.; Donahue, D.A.; Pushis, D.O.; Savoie, F.E.; Holland, J.W.; Wright, A.E.; August, C.; Bailey, J.L.; Patterson, D.R.

    1990-05-01

    The whole-pin furnace system is a new in-cell experimental facility constructed to investigate how irradiated fuel pins may fail under potential reactor accident conditions. Extensive checkouts have demonstrated excellent performance in remote operation, temperature control, pin breach detection, and fission gas handling. The system is currently being used in testing of EBIR-II-irradiated Integral Fast Reactor (IFR) metal fuel pins; future testing will include EBR-II-irradiated mixed-oxide fuel pins. 7 refs., 4 figs

  20. Irradiation Testing of Ultrasonic Transducers

    International Nuclear Information System (INIS)

    Daw, J.; Rempe, J.; Palmer, J.; Tittmann, B.; Reinhardt, B.; Kohse, G.; Ramuhalli, P.; Montgomery, R.; Chien, H.T.; Villard, J.F.

    2013-06-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10 21 n/cm 2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. (authors)

  1. Gamma irradiation facility: Evaluation of operational modes

    International Nuclear Information System (INIS)

    Adesanmi, C.A.; Ali, M.S.; Shonowo, O.A.; Akueche, E.C.; Sadare, O.O.; Mustapha, T.K.; Yusuf, U.; Inyanda, A.K.

    2007-01-01

    The multipurpose Gamma Irradiation Facility (GIF) at the Nuclear Technology Centre (NTC), Sheda Science and Technology Complex (SHETSCO), Abuja, Nigeria is designed as a semi-commercial plant with facilities for research and development (R and D). The design takes into account the different needs of the various research applications which require a wide dose range, a variety of techniques, different product sizes, shapes, mass, volume, densities and types. Programmable doses are used for food irradiation (0.04 - 10 kGy), biological seed mutation breeding and sterile insect technique (STI) (0.01- 5 kGy) sterilization of medical, pharmaceutical and cosmetic products and packages (up to 25 kGy) and cross-linking of polymers (up to 100 kGy). The six different modes of operations (sample elevator, stationary, swiveling, 2-path inner lane and 2-path outer lane and 4-path line) were evaluated. The dose range, mass range and range of irradiation time practicable were established and advantages for radiation processing of food and industrial products were enumerated for the six modes of operations for the first time

  2. Capsule Development and Utilization for Material Irradiation Tests

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N.

    2003-05-01

    The objective of this project was to establish basic capsule irradiation technology using the multi-purpose research reactor [HANARO] to eventually support national R and D projects of advanced fuel and materials related to domestic nuclear power plants and next generation reactors. There are several national nuclear projects in KAERI, which require several irradiation tests to investigate in-pile behavior of nuclear reactor fuel and materials for the R and D of several types of fuels such as advanced PWR and DUPIC fuels and for the R and D of structural materials such as RPV(reactor pressure vessel) steel, Inconel, zirconium alloy, and stainless steel. At the moment, internal and external researchers in institutes, industries and universities are interested in investigating the irradiation characteristics of materials using the irradiation facilities of HANARO. For these kinds of material irradiation tests, it is important to develop various capsules using our own techniques. The development of capsules requires several leading-edge technologies and our own experiences related to design and fabrication. In the second phase from April 1,2000 to March 31, 2003, the utilization technologies were developed using various sensors for the measurements of temperature, pressure and displacement, and instrumented capsule technologies for the required fuel irradiation tests were developed. In addition, the improvement of the existing capsule technologies and the development of an in-situ measurable creep capsule for specific purposes were done to meet the various requirements of users

  3. Performance test of the I and C system (GSF - 2002) for the irradiation tests using a fuel capsule

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Park, S. J.; Kim, B. G.; Ahn, D. H

    2004-12-01

    HANARO is a very important facility in Korea. It offers various types of irradiation tests of nuclear fuels and materials. With the various applications of the HANARO capsule for the academic and industrial applications, new technologies and relevant facilities will become more important especially for the advanced nuclear fuels and materials development. A new I and C system for an irradiation test using an instrumented fuel capsule have been designed and manufactured to provide more qualified data to fuel developer. The performance test which started in 2004, was done to investigate the thermal response of the capsule connected to the gas mixing system of the new I and C system(GSF-2002) in the cold test loop under the HANARO hydraulic operational condition. Main test parameters are mass flow rate of 25, 50 and 100 cc/min of He/Ne gas, gas pressure of 1 to 3 kg/cm{sup 2}, heater power of 1 to 3.4kW and different gas mixing ratios of He to Ne. From the out-pile tests, it was confirmed that the I and C system(GSF-2002) would be feasible for the fuel irradiation tests. Both analytical and test data prepared by this study are directly used for the fuel experiments related to advanced fuel development program.

  4. Fast Flux Test Facility core system

    International Nuclear Information System (INIS)

    Ethridge, J.L.; Baker, R.B.; Leggett, R.D.; Pitner, A.L.; Waltar, A.E.

    1990-11-01

    A review of Liquid Metal Reactor (LMR) core system accomplishments provides an excellent road map through the maze of issues that faced reactor designers 10 years ago. At that time relatively large uncertainties were associated with fuel pin and fuel assembly performance, irradiation of structural materials, and performance of absorber assemblies. The extensive core systems irradiation program at the US Department of Energy's Fast Flux Test Facility (FFTF) has addressed each of these principal issues. As a result of the progress made, the attention of long-range LMR planners and designers can shift away from improving core systems and focus on reducing capital costs to ensure the LMR can compete economically in the 21st century with other nuclear reactor concepts. 3 refs., 6 figs., 1 tab

  5. International Fusion Materials Irradiation Facility conceptual design activity. Present status and perspective

    International Nuclear Information System (INIS)

    Kondo, Tatsuo; Noda, Kenji; Oyama, Yukio

    1998-01-01

    For developing the materials for nuclear fusion reactors, it is indispensable to study on the neutron irradiation behavior under fusion reactor conditions, but there is not any high energy neutron irradiation facility that can simulate fusion reactor conditions at present. Therefore, the investigation of the IFMIF was begun jointly by Japan, USA, Europe and Russia following the initiative of IEA. The conceptual design activities were completed in 1997. As to the background and the course, the present status of the research on heavy irradiation and the testing means for fusion materials, the requirement and the technical basis of high energy neutron irradiation, and the international joint design activities are reported. The materials for fusion reactors are exposed to the neutron irradiation with the energy spectra up to 14 MeV. The requirements from the users that the IFMIF should satisfy, the demand of the tests for the materials of prototype and demonstration fusion reactors and the evaluation of the neutron field characteristics of the IFMIF are discussed. As to the conceptual design of the IFMIF, the whole constitution, the operational mode, accelerator system and target system are described. (K.I.)

  6. Survey of European LWR fuel irradiation test facilities

    Energy Technology Data Exchange (ETDEWEB)

    Hardt, P von der [Commission of the European Communities, Joint Research Centre, Petten Establishment, Petten (Netherlands)

    1983-06-01

    The first European commercial nuclear power plants (1956) featured gas-cooled thermal reactors. Although there is now a general orientation towards light water cooled plants (with a slight preference for the PWR) a large fraction of the 1982 nuclear generating capacity is still invested in gas-cooled reactors. R and D also continues for the HTGR with its long-term development potential. This paper, however, is limited to a general survey of experimental programmes and facilities for light water reactor fuel testing in Western Europe, particularly inside the European Communities. As it turns out, over a dozen major installations are available, all connected to research reactors in government-funded R and D centres. Their equipment is briefly reviewed. Some 50% of the experimental programmes are carried out in large international collaboration, involving up to 20 organizations per project. Techniques and results are rapidly communicated through frequent meetings and conferences. It is anticipated that a part of the present research reactor-based work will gradually shift to power reactor pool side inspection facilities. (author)

  7. Survey of European LWR fuel irradiation test facilities

    International Nuclear Information System (INIS)

    Hardt, P. von der

    1983-01-01

    The first European commercial nuclear power plants (1956) featured gas-cooled thermal reactors. Although there is now a general orientation towards light water cooled plants (with a slight preference for the PWR) a large fraction of the 1982 nuclear generating capacity is still invested in gas-cooled reactors. R and D also continues for the HTGR with its long-term development potential. This paper, however, is limited to a general survey of experimental programmes and facilities for light water reactor fuel testing in Western Europe, particularly inside the European Communities. As it turns out, over a dozen major installations are available, all connected to research reactors in government-funded R and D centres. Their equipment is briefly reviewed. Some 50% of the experimental programmes are carried out in large international collaboration, involving up to 20 organizations per project. Techniques and results are rapidly communicated through frequent meetings and conferences. It is anticipated that a part of the present research reactor-based work will gradually shift to power reactor pool side inspection facilities. (author)

  8. Irradiation facilities at the advanced neutron source

    International Nuclear Information System (INIS)

    West, C.D.

    1992-01-01

    The Advanced Neutron Source (ANS) is a facility, centered around a new 330MW(f) heavy-water cooled and reflected research reactor, proposed for construction at Oak Ridge. The main scientific justification for the new source is the United States' need for increased capabilities in neutron scattering and other neutron beam research, but the technical objectives of the project also cater for the need to replace the irradiation facilities at the aging High Flux Isotope Reactor and to provide other research capabilities to the scientific community. This document provides a description of the ANS facilities

  9. Fabrication of irradiation capsule for IASCC irradiation tests (2). Irradiation capsule for crack propagation test (Joint research)

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Matsui, Yoshinori; Kawamata, Kazuo; Taguchi, Taketoshi; Kanazawa, Yoshiharu; Onuma, Yuichi; Watanabe, Hiroyuki; Inoue, Shuichi; Izumo, Hironobu; Ishida, Takuya; Saito, Takashi; Ishitsuka, Etsuo; Kawamura, Hiroshi; Kaji, Yoshiyuki; Ugachi, Hirokazu; Tsukada, Takashi

    2008-03-01

    It is known that irradiation Assisted Stress Corrosion Cracking (IASCC) occurs when austenitic stainless steel components used for light water reactor (LWR) are irradiated for a long period. In order to evaluate the high aging of the nuclear power plant, the study of IASCC becomes the important problem. The specimens irradiated in the reactor were evaluated by post irradiation examination in the past study. For the appropriate evaluation of IASCC, it is necessary to test it under the simulated LWR conditions; temperature, water chemistry and irradiation conditions. In order to perform in-pile SCC test, saturated temperature capsule (SATCAP) was developed. There are crack growth test, crack propagation test and so on for in-pile SCC test. In this report, SATCAP for crack propagation test is reported. (author)

  10. Fabrication of irradiation capsule for IASCC irradiation tests (1). Irradiation capsule for crack growth test (Joint research)

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Matsui, Yoshinori; Kawamata, Kazuo; Taguchi, Taketoshi; Kanazawa, Yoshiharu; Onuma, Yuichi; Watanabe, Hiroyuki; Inoue, Shuichi; Izumo, Hironobu; Ishida, Takuya; Saito, Takashi; Ishitsuka, Etsuo; Kawamura, Hiroshi; Kaji, Yoshiyuki; Ugachi, Hirokazu; Tsukada, Takashi

    2008-03-01

    It is known that Irradiation Assisted Stress Corrosion Cracking (IASCC) occurs when austenitic stainless steel components used for light water reactor (LWR) are irradiated for a long period. In order to evaluate the high aging of the nuclear power plant, the study of IASCC becomes the important problem. The specimens irradiated in the reactor were evaluated by post irradiation examination in the past study. For the appropriate evaluation of IASCC, it is necessary to test it under the simulated LWR conditions; temperature, water chemistry and irradiation conditions. In order to perform in-pile SCC test, saturated temperature capsule (SATCAP) was developed. There are crack growth test, crack propagation test and so on for in-pile SCC test. In this report, SATCAP for crack growth test is reported. (author)

  11. Irradiation tests of radiation resistance optical fibers for fusion diagnostic application

    Science.gov (United States)

    Kakuta, Tsunemi; Shikama, Tatsuo; Nishitani, Takeo; Yamamoto, Shin; Nagata, Shinji; Tsuchiya, Bun; Toh, Kentaro; Hori, Junichi

    2002-11-01

    To promote development of radiation-resistant core optical fibers, the ITER-EDA (International Thermonuclear Experimental Reactor-Engineering Design Activity) recommended carrying out international round-robin irradiation tests of optical fibers to establish a reliable database for their applications in the ITER plasma diagnostics. Ten developed optical fibers were irradiation-tested in a Co-60 gamma cell, a Japan Materials Testing Reactor (JMTR). Also, some of them were irradiation tested in a fast neutron irradiation facility of FNS (Fast Neutron Source), especially to study temperature dependence of neutron-associated irradiation effects. Included were several Japanese fluorine doped fibers and one Japanese standard fiber (purified and undoped silica core), as well as seven Russian fibers. Some of Russian fibers were drawn by Japanese manufactures from Russian made pre-form rods to study effects of manufacturing processes to radiation resistant properties. The present paper will describe behaviors of growth of radiation-induced optical transmission loss in the wavelength range of 350-1750nm. Results indicate that role of displacement damages by fast neutrons are very important in introducing permanent optical transmission loss. Spectra of optical transmission loss in visible range will depend on irradiation temperatures and material parameters of optical fibers.

  12. γ irradiation facility at ENEA-Casaccia Centre (Rome)

    International Nuclear Information System (INIS)

    Baccaro, S.; Cecilia, A.; Pasquali, A.

    2005-09-01

    A description of Calliope γ irradiation plant of ENEA-Casaccia Centre (Rome) is presented in this paper. In particular the main characteristics of the irradiation facility necessary to define time and irradiation procedure are summarised. The plant is equipped with dosimetric services that evaluate absorbed doses in materials during irradiation. Dosimetric techniques used are Fricke, RedPerspex and alanine-ESR dosimetries. In the first case, absorbed dose is determined by chemical changes induced in a solution by irradiation and the second method uses the optical density increase induced in dosimeter by irradiation. The last method is based on the analysis of the free radical concentration induced in α-alanine amino-acid during irradiation. The paper provides also a simulation of the γ radiation field inside the irradiation cell realised by using FLUKA code, which includes a good description of the electromagnetic physics down to about 0.1 KeV [it

  13. Dosimetry and operation of irradiation facilities

    International Nuclear Information System (INIS)

    Vidal, P.E.

    1985-01-01

    The industrial use of ionizing radiation has required, from the very first, the measurement of delivered and absorbed doses; hence the necessity of providing dosimetric systems. Laboratories, scientists, industries and potential equipment manufacturers have all collaborated in this new field of activity. Dosimetric intercomparisons have been made by each industry at their own facilities and in collaboration with specialists, national organizations and the IAEA. Dosimetry has become a way of ensuring that treatment by irradiation has been carried out in accordance with the rules. It has become in effect assurance of quality. Routine dosimetry should determine a maximum and minimum dose. Numerous factors play a part in dosimetry. Industry is currently in possession of routine dosimetric systems that are sufficiently accurate, fairly easy to handle and reasonable in cost, thereby satisfying all the requirements of industry and the need for control. Dosimetry is important in the process of marketing irradiated products. The operator of an industrial irradiation facility bases his dosimetry on comparison with reference systems. Research aimed at simplifying the practice of routine dosimetry should be continued. New physical and chemical techniques will be incorporated into systems already in use. The introduction of microcomputers into the operation of radiation facilities has increased the value of dosimetry and made the conditions of treatment more widespread. Stress should be placed on research in several areas apart from reference systems, for example: dosimetric systems at temperatures from +8 deg. C to -45 deg. C, over the dose range 100 krad to a little more than 1 Mrad, liquids and fluidized solids carried at high speed through ducts, thin-film liquids circulating at a high flow rate, and various other problems. (author)

  14. Design and fuel fabrication processes for the AC-3 mixed-carbide irradiation test

    International Nuclear Information System (INIS)

    Latimer, T.W.; Chidester, K.M.; Stratton, R.W.; Ledergerber, G.; Ingold, F.

    1992-01-01

    The AC-3 test was a cooperative U.S./Swiss irradiation test of 91 wire-wrapped helium-bonded U-20% Pu carbide fuel pins irradiated to 8.3 at % peak burnup in the Fast Flux Test Facility. The test consisted of 25 pins that contained spherepac fuel fabricated by the Paul Scherrer Institute (PSI) and 66 pins that contained pelletized fuel fabricated by the Los Alamos National Laboratory. Design of AC-3 by LANL and PSI was begun in 1981, the fuel pins were fabricated from 1983 to 1985, and the test was irradiated from 1986 to 1988. The principal objective of the AC-3 test was to compare the irradiation performance of mixed-carbide fuel pins that contained either pelletized or sphere-pac fuel at prototypic fluence and burnup levels for a fast breeder reactor

  15. SUPER-FMIT, an accelerator-based neutron source for fusion components irradiation testing

    International Nuclear Information System (INIS)

    Burke, R.J.; Holmes, J.J.; Johnson, D.L.; Mann, F.M.; Miles, R.R.

    1984-01-01

    The SUPER-FMIT facility is proposed as an advanced accelerator based neutron source for high flux irradiation testing of large-sized fusion reactor components. The facility would require only small extensions to existing accelerator and target technology originally developed for the Fusion Materials Irradiation Test (FMIT) facility. There, neutrons would be produced by a 0.1 ampere beam of 35 MeV deuterons incident upon a liquid lithium target. The volume available for high flux (> 10 14 n/cm 2 -s) testing in SUPER-FMIT would be 14 liters, about a factor of 30 larger than in the FMIT facility. This is because the effective beam current of 35 MeV deuterons on target can be increased by a factor of ten to 1.0 amperes or more. Such a large increase can be accomplished by acceleration of multiple beams of molecular deuterium ions (D 2 +) to 70 MeV in a common accelerator sructure. The availability of multiple beams and large total current allows great variety in the testing that can be done. For example, fluxes greater than 10 16 n/cm 2 -s, multiple simultaneous experiments, and great flexibility in tailoring of spatial distributions of flux and spectra can be achieved

  16. Post-irradiation examination and R and D programs using irradiated fuels at KAERI

    International Nuclear Information System (INIS)

    Chun, Yong Bum; Min, Duck Kee; Kim, Eun Ka and others

    2000-12-01

    This report describes the Post-Irradiation Examination(PIE) and R and D programs using irradiated fuels at KAERI. The objectives of post-irradiation examination (PIE) for the PWR irradiated fuels, CANDU fuels, HANARO fuels and test fuel materials are to verify the irradiation performance and their integrity as well as to construct a fuel performance data base. The comprehensive utilization program of the KAERI's post-irradiation examination related nuclear facilities such as Post-Irradiation Examination Facility (PIEF), Irradiated Materials Examination Facility (IMEF) and HANARO is described

  17. Post-irradiation examination and R and D programs using irradiated fuels at KAERI

    International Nuclear Information System (INIS)

    Chun, Yong Bum; So, Dong Sup; Lee, Byung Doo; Lee, Song Ho; Min, Duck Kee

    2001-09-01

    This report describes the Post-Irradiation Examination(PIE) and R and D programs using irradiated fuels at KAERI. The objectives of post-irradiation examination (PIE) for the PWR irradiated fuels, CANDU fuels, HANARO fuels and test fuel materials are to verify the irradiation performance and their integrity as well as to construct a fuel performance data base. The comprehensive utilization program of the KAERI's post-irradiation examination related nuclear facilities such as Post-Irradiation Examination Facility (PIEF), Irradiated Materials Examination Facility (IMEF) and HANARO is described

  18. Radiation Safety of Gamma, Electron and X Ray Irradiation Facilities. Specific Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2015-01-01

    The objective of this Safety Guide is to provide recommendations on how to meet the requirements of the BSS with regard to irradiation facilities. This Safety Guide provides specific, practical recommendations on the safe design and operation of gamma, electron and X ray irradiators for use by operating organizations and the designers of these facilities, and by regulatory bodies. SCOPE. The facilities considered in this publication include five types of irradiator, whether operated on a commercial basis or for research and development purposes. This publication is concerned with radiation safety issues and not with the uses of irradiators, nor does it cover the irradiation of product or its quality management. The five types of irradiator are: - Panoramic dry source storage irradiators; - Underwater irradiators, in which both the source and the product being irradiated are under water; - Panoramic wet source storage irradiators; - Electron beam irradiation facilities, in which irradiation is performed in an area that is potentially accessible to personnel, but that is kept inaccessible during the irradiation process; - X ray irradiation facilities, in which irradiation is performed in an area that is potentially accessible to personnel, but that is kept inaccessible during the irradiation process. Consideration of non-radiation-related risks and of the benefits resulting from the operation of irradiators is outside the scope of this Safety Guide. The practices of radiotherapy and radiography are also outside the scope of this Safety Guide. Category I gamma irradiators (i.e. 'self-shielded' irradiators) are outside the scope of this Safety Guide

  19. Irradiation and testing of compact ignition tokamak toroidal field coil insulation materials

    International Nuclear Information System (INIS)

    Kanemoto, G.K.; Sherick, M.J.; Sparks, D.C.

    1990-05-01

    This report documents the results of an irradiation and testing program performed on behalf of Martin Marietta Energy Systems, Inc. in support of the Compact Ignition Tokamak Research and Development program. The purpose of the irradiation and testing program was to determine the effects of neutron and gamma irradiation on the mechanical and electrical properties of candidate toroidal field coil insulation materials. Insulation samples were irradiated in the Advanced Test Reactor (ATR) in a large I-hole. The insulation samples were irradiated within a lead shield to reduce exposure to gamma radiation to better approximate the desired ration of neutron to gamma exposure. Two different exposure levels were specified for the insulation samples. To accomplish this, the samples were encapsulated in two separate aluminum capsules; the capsules positioned at the ATR core mid-plane and at the top of the fueled region to take advantage of the axial cosine distribution of the neutron and gamma flux; and by varying the length of irradiation time of the two capsules. Disassembly of the irradiated capsules and testing of the insulation samples were performed at the Test Reactor Area (TRA) Hot Cell Facilities. Testing of the samples included shear compression static, shear compression fatigue, flexure static, and electrical resistance measurements

  20. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Croucher, D.W.; Yackle, T.R.; Allison, C.M.; Ploger, S.A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m 2 for each rod. After a flow reduction to 1800 kg/s-m 2 , film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m 2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  1. Advancing nuclear technology and research. The advanced test reactor national scientific user facility

    Energy Technology Data Exchange (ETDEWEB)

    Benson, Jeff B; Marshall, Frances M [Idaho National Laboratory, Idaho Falls, ID (United States); Allen, Todd R [Univ. of Wisconsin, Madison, WI (United States)

    2012-03-15

    The Advanced Test Reactor (ATR), at the Idaho National Laboratory (INL), is one of the world's premier test reactors for providing the capability for studying the effects of intense neutron and gamma radiation on reactor materials and fuels. The INL also has several hot cells and other laboratories in which irradiated material can be examined to study material radiation effects. In 2007 the US Department of Energy (DOE) designated the ATR as a National Scientific User Facility (NSUF) to facilitate greater access to the ATR and the associated INL laboratories for material testing research. The mission of the ATR NSUF is to provide access to world-class facilities, thereby facilitating the advancement of nuclear science and technology. Cost free access to the ATR, INL post irradiation examination facilities, and partner facilities is granted based on technical merit to U.S. university-led experiment teams conducting non-proprietary research. Proposals are selected via independent technical peer review and relevance to United States Department of Energy. To increase overall research capability, ATR NSUF seeks to form strategic partnerships with university facilities that add significant nuclear research capability to the ATR NSUF and are accessible to all ATR NSUF users. (author)

  2. Facilities and procedures used for the performance testing of DOE personnel dosimetry systems

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, P.L.; Fox, R.A.; Hogan, R.T.; Holbrook, K.L.; Hooker, C.D.; Yoder, R.C.

    1983-04-01

    Radiological calibration facilities for personnel dosimeter testing were developed at the Pacific Northwest Laboratory (PNL) for the Department of Energy (DOE) to provide a capability for evaluating the performance of DOE personnel dosimetry systems. This report includes the testing methodology used. The informational presented here meets requirements specified in draft ANSI N13.11 for the testing laboratory. The capabilities of these facilities include sealed source irradiations for /sup 137/Cs, several beta-particle emitters, /sup 252/Cf, and machine-generated x-ray beams. The x-ray beam capabilities include filtered techniques maintained by the National Bureau of Standards (NBS) and K-fluorescent techniques. The calibration techniques, dosimeter irradiation procedures, and dose-equivalent calculation methods follow techniques specified by draft ANSI N13.11 where appropriate.

  3. Facilities and procedures used for the performance testing of DOE personnel-dosimetry systems

    International Nuclear Information System (INIS)

    Roberson, P.L.; Fox, R.A.; Hogan, R.T.; Holbrook, K.L.; Hooker, C.D.; Yoder, R.C.

    1983-04-01

    Radiological calibration facilities for personnel dosimeter testing were developed at the Pacific Northwest Laboratory (PNL) for the Department of Energy (DOE) to provide a capability for evaluating the performance of DOE personnel dosimetry systems. This report includes the testing methodology used. The informational presented here meets requirements specified in draft ANSI N13.11 for the testing laboratory. The capabilities of these facilities include sealed source irradiations for 137 Cs, several beta-particle emitters, 252 Cf, and machine-generated x-ray beams. The x-ray beam capabilities include filtered techniques maintained by the National Bureau of Standards (NBS) and K-fluorescent techniques. The calibration techniques, dosimeter irradiation procedures, and dose-equivalent calculation methods follow techniques specified by draft ANSI N13.11 where appropriate

  4. Use of the SPIRAL 2 facility for material irradiations with 14 MeV energy neutrons

    International Nuclear Information System (INIS)

    Mosnier, A.; Ridikas, D.; Ledoux, X.; Pellemoine, F.; Anne, R.; Huguet, Y.; Lipa, M.; Magaud, P.; Marbach, G.; Saint-Laurent, M.G.; Villari, A.C.C.

    2005-01-01

    The primary goal of an irradiation facility for fusion applications will be to generate a material irradiation database for the design, construction, licensing and safe operation of a fusion demonstration power station (e.g., DEMO). This will be achieved through testing and qualifying material performance under neutron irradiation that simulates service up to the full lifetime anticipated in the power plant. Preliminary investigations of 14 MeV neutron effects on different kinds of fusion material could be assessed by the SPIRAL 2 Project at GANIL (Caen, France), aiming at rare isotope beams production for nuclear physics research with first beams expected by 2009. In SPIRAL 2, a deuteron beam of 5 mA and 40 MeV interacts with a rotating carbon disk producing high-energy neutrons (in the range between 1 and 40 MeV) via C (d, xn) reactions. Then, the facility could be used for 3-4 months y -1 for material irradiation purposes. This would correspond to damage rates in the order of 1-2 dpa y -1 (in Fe) in a volume of ∼10 cm 3 . Therefore, the use of miniaturized specimens will be essential in order to effectively utilize the available irradiation volume in SPIRAL 2. Sample package irradiation temperature would be in the range of 250-1000 deg. C. The irradiation level of 1-2 dpa y -1 with 14 MeV neutrons (average energy) may be interesting for micro-structural and metallurgical investigations (e.g., mini-traction, small punch tests, etc.) and possibly for the understanding of specimen size/geometric effects of critical material properties. Due to the small test cell volume, sample in situ experiments are not foreseen. However, sample packages would be, if required, available each month after transfer in a special hot cell on-site

  5. Design and construction of γ-rays irradiation facility for remote-handling parts and components of fusion reactor

    International Nuclear Information System (INIS)

    Yagi, Toshiaki; Morita, Yousuke; Seguchi, Tadao

    1995-03-01

    For the evaluation of radiation resistance of remote-handling system for International Thermonuclear Experimental Reactor(ITER), 'high dose-rate and high temperature (upper 350degC) γ-rays irradiation facility' was designed and constructed. In this facility, the parts and components of remote-handling system such as sensing devices, motors, optical glasses, wires and cables, etc., are tested by irradiation with 2x10 6 Roentgen/h Co-60 γ-rays at a temperature up to 350degC under various atmospheres (dry nitrogen gas, argon gas, dry air and vacuum). (author)

  6. Two-faces stationary irradiation method and dosimetric considerations for radiation processing at the multipurpose gamma irradiation facility / IPEN-CNEN

    International Nuclear Information System (INIS)

    Santos, Paulo S.; Vasquez, Pablo A.S.

    2015-01-01

    Over the last ten years, the Multipurpose Gamma Irradiation Facility of the Nuclear and Energy Research Institute - IPEN/CNEN located inside the Sao Paulo University campus has been providing services on radiation processing, especially for sterilization of health care and disposable medical products as well as support to research studies on modification of physical, chemical and biological properties of several materials. Placed at the same campus operates an extremely important radiopharmaceutical production facility when almost all disposable supplies used to produce medical products as the technetium-99m are continuously sterilized by gamma radiation. Many university biomedical research laboratories specially those working with equipment for cell cultures and vaccine production also make use of the gamma sterilization. Animal feed and shavings used by certified bioteries are routinely disinfected. Alternative underwater irradiation methods were developed to meet the demand of gemstone color enhancement. Human tissues including bone, skin, amniotic membranes, tendons, and cartilage belonging to National Banks are usually irradiated too. Different kind of polymers, hydrogels, foods as well native fruits, have been irradiated in this facility. Cultural heritage objects as books, paintings and furniture are disinfected routinely by gamma radiation. The success of the implementation of radiation processing in this facility is due to research and development of irradiation and dosimetry methods suitable for each condition. In this work are presented some considerations about the distribution dose and the two-faces stationary irradiation method developed and validated for this facility. (author)

  7. Two-faces stationary irradiation method and dosimetric considerations for radiation processing at the multipurpose gamma irradiation facility / IPEN-CNEN

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo S.; Vasquez, Pablo A.S., E-mail: psantos@ipen.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Over the last ten years, the Multipurpose Gamma Irradiation Facility of the Nuclear and Energy Research Institute - IPEN/CNEN located inside the Sao Paulo University campus has been providing services on radiation processing, especially for sterilization of health care and disposable medical products as well as support to research studies on modification of physical, chemical and biological properties of several materials. Placed at the same campus operates an extremely important radiopharmaceutical production facility when almost all disposable supplies used to produce medical products as the technetium-99m are continuously sterilized by gamma radiation. Many university biomedical research laboratories specially those working with equipment for cell cultures and vaccine production also make use of the gamma sterilization. Animal feed and shavings used by certified bioteries are routinely disinfected. Alternative underwater irradiation methods were developed to meet the demand of gemstone color enhancement. Human tissues including bone, skin, amniotic membranes, tendons, and cartilage belonging to National Banks are usually irradiated too. Different kind of polymers, hydrogels, foods as well native fruits, have been irradiated in this facility. Cultural heritage objects as books, paintings and furniture are disinfected routinely by gamma radiation. The success of the implementation of radiation processing in this facility is due to research and development of irradiation and dosimetry methods suitable for each condition. In this work are presented some considerations about the distribution dose and the two-faces stationary irradiation method developed and validated for this facility. (author)

  8. Control and safety systems for TRIGA irradiation facilities C5 and C9

    International Nuclear Information System (INIS)

    Talpalariu Cornel Talpalariu Jeni Crucean Mircea Matei Corina

    2008-01-01

    Full text: The Institute for Nuclear Research conducted research for designing and manufacturing of microprocessor equipment for some irradiation facilities operating by the TRIGA reactor. This equipment has accumulated a wide operating time allowing the conclusions referring to reliability, ergonomics, and design of the operating facilities. Based upon these studies a new program was initiated for the design and manufacturing of a modern equipment with improved reliability and flexibility performances. The system provides the user with a multitude of options, numerical and analog interfaces, keyboard and high reliability local display. The main functional components of the system are: - 8 PID full options regulating loops; - 8 safety analog channels having 4 preset trips; - watch dog restart and fault tolerant facilities; - 8 high precision analog with an input of 0 - 15 mV from thermocouple; - 8 computer controlled power supplies of 220 V, 1 kWA; - alphanumeric display and keyboard; - fault tolerant analog scanner. A real improvement of the system is the future remote control computer, a PC AT Pentium working like a system controller, real time data acquisition, and operator's adviser. This new facility allows the operator to set the trips or to control remotely all the power supply and step-by-step positioner of irradiation device. Software design for acquisition and data processing provides modern techniques for operator interfacing, representation recording and protection of test results. Software implementation keeps a special organization supported by a real time executive that is the best method to achieve the performance required. Following this objective, the software structure consists of: 1. Tasks as follows: - testing parameters setup; - data processing routines; - engineering and electrical conversion; - numerical / graphical data representation; - test results recording routines and data base management. 2. Drivers as follows: - A/I and D

  9. Project accent: graphite irradiated creep in a materials test reactor

    International Nuclear Information System (INIS)

    Brooking, M.

    2014-01-01

    Atkins manages a pioneering programme of irradiation experiments for EDF Energy. One of these projects is Project ACCENT, designed to obtain evidence of a beneficial physical property of the graphite, which may extend the life of the Advanced Gas-cooled Reactors (AGRs). The project team combines the in-house experience of EDF Energy with two supplier organisations (providing the material test reactors and testing facilities) and supporting consultancies (Atkins and an independent technical expert). This paper describes: - Brief summary of the Project; - Discussion of the challenges faced by the Project; and - Conclusion elaborating on the aims of the Project. These challenging experiments use bespoke technology and both un-irradiated (virgin) and irradiated AGR graphite. The results will help to better understand graphite irradiation-induced creep (or stress modified dimensional change) properties and therefore more accurately determine lifetime and safe operating envelopes of the AGRs. The first round of irradiation has been completed, with a second round about to commence. This is a key step to realising the full lifetime ambition for AGRs, demonstrating the relaxation of stresses within the graphite bricks. (authors)

  10. Operation of post-irradiation examination facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ka; Park, Kwang Joon; Jeon, Yong Bum [and others; Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-02-01

    In 1995, the post-irradiation examination (PIE) of nuclear fuels was performed as follows. The relation between burnup and top nozzle spring force of fuel assembly was obtained by measuring the holddown spring force on the Kori-1 reactor fuel assemblies. The resonance ultrasonic test for inspection of defect and moisture in fuel rod was carried out on fuel rods of C15 and J14 assemblies, and the change of fuel rod condition by storing in pool has been analyzed on the intentionally defected fuel rods (ID-C and ID-L) as well as intact fuel rod (1-2) by NDT in ht cell. The oxide layer thickness on cladding surface of J44-L12 fuel rod was measured by NDT method and metallography to reveal the oxidation as a function of temperature in the fuel rod, and the burnup of J44 fuel assembly was measured by chemical analysis. HVAC system and pool water treatment system of the PIE facility were continuously operated for air filtration and water purification. The monitoring of radiation and pool water in PIE facility has been carried out to maintain the facility safety, and electric power supply system was checked and maintained to supply the electric power to the facility normally. The developed measurement techniques of oxide layer thickness on fuel rod cladding and holddown spring force of top nozzle in fuel assembly were applied to examine the nuclear fuels. Besides, a radiation shielding glove box was designed and a hot cell compressor for volume reduction of radioactive materials was fabricated. 19 tabs., 38 figs., 7 refs. (Author) .new.

  11. International Fusion Materials Irradiation Facility injector acceptance tests at CEA/Saclay: 140 mA/100 keV deuteron beam characterization

    International Nuclear Information System (INIS)

    Gobin, R.; Bogard, D.; Chauvin, N.; Chel, S.; Delferrière, O.; Harrault, F.; Mattei, P.; Senée, F.; Cara, P.; Mosnier, A.; Shidara, H.; Okumura, Y.

    2014-01-01

    In the framework of the ITER broader approach, the International Fusion Materials Irradiation Facility (IFMIF) deuteron accelerator (2 × 125 mA at 40 MeV) is an irradiation tool dedicated to high neutron flux production for future nuclear plant material studies. During the validation phase, the Linear IFMIF Prototype Accelerator (LIPAc) machine will be tested on the Rokkasho site in Japan. This demonstrator aims to produce 125 mA/9 MeV deuteron beam. Involved in the LIPAc project for several years, specialists from CEA/Saclay designed the injector based on a SILHI type ECR source operating at 2.45 GHz and a 2 solenoid low energy beam line to produce such high intensity beam. The whole injector, equipped with its dedicated diagnostics, has been then installed and tested on the Saclay site. Before shipment from Europe to Japan, acceptance tests have been performed in November 2012 with 100 keV deuteron beam and intensity as high as 140 mA in continuous and pulsed mode. In this paper, the emittance measurements done for different duty cycles and different beam intensities will be presented as well as beam species fraction analysis. Then the reinstallation in Japan and commissioning plan on site will be reported

  12. Preliminary irradiation test results from the Yankee Atomic Electric Company reactor vessel test irradiation program

    International Nuclear Information System (INIS)

    Biemiller, E.C.; Fyfitch, S.; Campbell, C.A.

    1993-01-01

    The Yankee Atomic Electric Company test irradiation program was implemented to characterize the irradiation response of representative Yankee Rowe reactor vessel beltline plate materials and to remove uncertainties in the analysis of existing irradiation data on the Yankee Rowe reactor vessel steel. Plate materials each containing 0.24 w/o copper, but different nickel contents at 0.63 w/o and 0.19 w/o, were heat treated to simulate the Yankee vessel heat treatment (austenitized at 1800 deg F) and to simulate Regulatory Guide 1.99 database materials (austenitized at 1600 deg. F). These heat treatments produced different microstructures so the effect of microstructure on irradiation damage sensitivity could be tested. Because the nickel content of the test plates varied and the copper level was constant, the effect of nickel on irradiation embrittlement was also tested. Correlation monitor material, HSST-02, was included in the program to benchmark the Ford Nuclear Reactor (U. of Michigan Test Reactor) which had never been used for this type of irradiation program. Materials taken from plate surface locations (vs. 1/4T) were included to test whether or not the improved toughness properties of the plate surface layer, resulting from the rapid quench, is maintained after irradiation. If the improved properties are maintained, pressurized thermal shock calculations could utilize this margin. Finally, for one experiment, irradiations were conducted at two irradiation temperatures (500 deg. F and 550 deg. F) to determine the effect of irradiation temperature on embrittlement. The preliminary results of the irradiation program show an increase in T 30 shift of 69 deg. F for a decrease in irradiation temperature of 50 deg. F. The results suggest that for nickel bearing steels, the superior toughness of plate surface material is maintained after irradiation and for the copper content tested, nickel had no apparent effect on irradiation response. No apparent microstructure

  13. Shiva target irradiation facility

    International Nuclear Information System (INIS)

    Manes, K.R.; Ahlstrom, H.G.; Coleman, L.W.; Storm, E.K.; Glaze, J.A.; Hurley, C.A.; Rienecker, F.; O'Neal, W.C.

    1977-01-01

    The first laser/plasma studies performed with the Shiva laser system will be two sided irradiations extending the data obtained by other LLL lasers to higher powers. The twenty approximately 1 TW laser pulses will reach the target simultaneously from above and below in nested pentagonal clusters. The upper and lower clusters of ten beams each are radially polarized so that they strike the target in p-polarization and maximize absorption. This geometry introduces laser system isolation problems which will be briefly discussed. The layout and types of target diagnostics will be described and a brief status report on the facility given

  14. Gamma irradiation for sewage treatment at US army facilities

    International Nuclear Information System (INIS)

    Van den Berg, A.J.; Hollis, H.D.; Musselman, H.D.; Woodbridge, D.D.

    1975-01-01

    The US Army Corps of Engineers has been sponsoring research for many years on the use of gamma irradiation for disinfection and sterilization of sewage plant effluents. Initial research was directed to laboratory experiments using sterile solutions to determine the effects of gamma irradiation on E. coli, M-pyogenes and M-smegmatis organisms, and on the chemical constituents of sewage such as phenols, surfactants and pesticides. The results of the initial research warranted further study using municipal sewage secondary effluent as test samples. Current research is directed towards investigating the effects of radiation on the constituents of sewage sludge and on the cyst stage of the amoebic protozoa. Consideration has been given by the Corps to the management of waste-waters by disposal on land. Legal and medical reasons dictate that the plant effluents be sterilized before being used as fertilizers and soil conditioners. Gamma radiation from isotopic sources appears to be the best source of sterilizing energy for Army waste-water disposal. The Corps of Engineers is considering the construction of an experimental gamma irradiation pilot facility to validate laboratory experimental work and to establish design criteria for operating plants. The data obtained will provide a basis for performing detailed cost effectiveness studies on gamma irradiation as a method to treat secondary plant effluent. In addition, optimization work will be conducted to determine where in the sewage treatment cycle the use of gamma irradiation will produce the best results in meeting current and anticipated standards. (author)

  15. Post-irradiation handling and examination at the HFEF complex

    International Nuclear Information System (INIS)

    Bacca, J.P.

    1980-01-01

    The Hot Fuel Examination Facility provides postirradiation handling and examination of fast reactor irradiation experiments and safety tests for the United States Breeder Reactor Program. Nondestructive interim examinations and destructive terminal examinations at HFEF derive data from tests irradiated in the Experimental Breeder Reactor No. II, in the Transient Reactor Test Facility (TREAT), and in the Sodium Loop Safety Facility. Similar support will be provided in the near future for tests irradiated in the Fast Flux Test Facility, and for the larger sodium loops to be irradiated in TREAT

  16. Technology Implementation Plan: Irradiation Testing and Qualification for Nuclear Thermal Propulsion Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Thomas J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Howard, Richard H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rader, Jordan D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    This document is a notional technology implementation plan (TIP) for the development, testing, and qualification of a prototypic fuel element to support design and construction of a nuclear thermal propulsion (NTP) engine, specifically its pre-flight ground test. This TIP outlines a generic methodology for the progression from non-nuclear out-of-pile (OOP) testing through nuclear in-pile (IP) testing, at operational temperatures, flows, and specific powers, of an NTP fuel element in an existing test reactor. Subsequent post-irradiation examination (PIE) will occur in existing radiological facilities. Further, the methodology is intended to be nonspecific with respect to fuel types and irradiation or examination facilities. The goals of OOP and IP testing are to provide confidence in the operational performance of fuel system concepts and provide data to program leadership for system optimization and fuel down-selection. The test methodology, parameters, collected data, and analytical results from OOP, IP, and PIE will be documented for reference by the NTP operator and the appropriate regulatory and oversight authorities. Final full-scale integrated testing would be performed separately by the reactor operator as part of the preflight ground test.

  17. Endurance test of DUPIC irradiation test rig-003

    Energy Technology Data Exchange (ETDEWEB)

    Moon, J.S; Yang, M.S.; Lee, C.Y.; Ryu, J.S.; Jeon, H.G

    2001-04-01

    This report presents the pressure drop, vibration and endurance test results for DUPIC Irradiation Test Rig-003 which was design and fabricated by KAERI. From the pressure drop and vibration test results, it is verified that DUPIC Irradiation Test Rig-003 satisfied the limit conditions of HANARO. And, remarkable wear is not observed in DUPIC Irradiation Test Rig-003 during 40 endurance test days.

  18. Market testing of irradiated food

    International Nuclear Information System (INIS)

    Duc, Ho Minh

    2001-01-01

    Viet Nam has emerged as one of the three top producers and exporters of rice in the world. Tropical climate and poor infrastructure of preservation and storage lead to huge losses of food grains, onions, dried fish and fishery products. Based on demonstration irradiation facility pilot scale studies and marketing of irradiated rice, onions, mushrooms and litchi were successfully undertaken in Viet Nam during 1992-1998. Irradiation technology is being used commercially in Viet Nam since 1991 for insect control of imported tobacco and mould control of national traditional medicinal herbs by both government and private sectors. About 30 tons of tobacco and 25 tons of herbs are irradiated annually. Hanoi Irradiation Centre has been continuing open house practices for visitors from school, universities and various different organizations and thus contributed in improved public education. Consumers were found to prefer irradiated rice, onions, litchi and mushrooms over those nonirradiated. (author)

  19. Irradiation effects test series, test IE-5. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Croucher, D. W.; Yackle, T. R.; Allison, C. M.; Ploger, S. A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m/sup 2/ for each rod. After a flow reduction to 1800 kg/s-m/sup 2/, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m/sup 2/ produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results.

  20. Monte Carlo studies of the Portuguese gamma irradiation facility. The irradiator geometry and its influence on process parameters

    International Nuclear Information System (INIS)

    Oliveira, C.; Ferreira, L.; Salgado, J.

    2001-01-01

    The paper describes a Monte Carlo study of dose distributions, minimum dose and uniformity ratio for the Portuguese Gamma Irradiation Facility. These process parameters are calculated using the MCNP code for several irradiator geometries. The comparison of the simulated results with the experimental results carried out using Amber Perspex dosimeters in a routine process of the gamma facility for a given material composition and density reveals good agreement. The results already obtained allow to conclude that the dose uniformity is not very sensitive to the irradiator geometry for density value ρ = 0.1 and for a dynamic process. (orig.)

  1. Facilities for post-irradiation examination of experimental fuel elements at Chalk River Nuclear Laboratories

    International Nuclear Information System (INIS)

    Mizzan, E.; Chenier, R.J.

    1979-10-01

    Expansion of post-irradiation facilities at the Chalk River Nuclear Laboratories and steady improvement in hot-cell techniques and equipment are providing more support to Canada's reactor fuel development program. The hot-cell facility primarily used for examination of experimental fuels averages a quarterly throughput of 40 elements and 110 metallographic specimens. New developments in ultrasonic testing, metallographic sample preparation, active storage, active waste filtration, and fissile accountability are coming into use to increase the efficiency and safety of hot-cell operations. (author)

  2. Biological shielding design and qualification of concreting process for construction of electron beam irradiation facility

    International Nuclear Information System (INIS)

    Petwal, V.C.; Kumar, P.; Suresh, N.; Parchani, G.; Dwivedi, J.; Thakurta, A.C.

    2011-01-01

    A technology demonstration facility for irradiation of food and agricultural products is being set-up by RRCAT at Indore. The facility design is based on linear electron accelerator with maximum beam power of 10 kW and can be operated either in electron mode at 10 MeV or photon modes at 5/7.5 MeV. Biological shielding has been designed in accordance with NCRP 51 to achieve dose rate at all accessible points outside the irradiation vault less than the permissible limit of 0.1 mR/hr. In addition to radiation attenuation property, concrete must have satisfactory mechanical properties to meet the structural requirements. There are number of site specific variables which affect the structural, thermal and radiological properties of concrete, leading to considerable difference in actual values and design values. Hence it is essential to establish a suitable site and environmental specific process to cast the concrete and qualify the process by experimental measurement. For process qualification we have cast concrete test blocks of different thicknesses up to 3.25 m and evaluated the radiological and mechanical properties by radiometry, ultrasonic and mechanical tests. In this paper we describe the biological shielding design of the facility and analyse the results of tests carried out for qualification of the process. (author)

  3. Seed irradiation facilities at TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Najzer, M.

    1972-01-01

    Fast neutrons and gamma-rays with their high and low LET respectively are excellent complementary tools for investigation of the effect of different types of mutations. TRIGA Irradiation Facility and Thermal Column Irradiation Facility were designed and installed for the first time in the TRIGA tank and thermal column respectively. The basic idea of design was the use of depleted uranium as gamma-ray and thermal neutron shield and simultaneously as thermal to fast neutron converter. Low LET radiation, due to direct and thermal neutron capture gamma-rays, is strongly attenuated while fast neutron flux is increased. GIF is made of a cadmium tube inserted in a graphite block. It is located in the central thermal column channel. The basic idea is to convert thermal neutrons to gamma-rays by capture in the cadmium

  4. A New High-intensity Proton Irradiation Facility at the CERN PS East Area

    CERN Document Server

    Gkotse, B; Lima, P; Matli, E; Moll, M; Ravotti, F

    2014-01-01

    and IRRAD2), were heavily and successfully used for irradiation of particle detectors, electronic components and materials since 1992. These facilities operated with particle bursts - protons with momentum of 24GeV/c - delivered from the PS accelerator in “spills” of about 400ms (slow extraction). With the increasing demand of irradiation experiments, these facilities suffered from a number of restrictions such as the space availability, the maximum achievable particle flux and several access constraints. In the framework of the AIDA project, an upgrade of these facilities has been realized during the CERN long shutdown (LS1). While the new proton facility (IRRAD) will continue to be mainly devoted to the radiation hardness studies for the High Energy Physics (HEP) experimental community, the new mixed-field facility (CHARM) will mainly host irradiation experiments for the validation of electronic systems used in a...

  5. Test facility of transport packagings for radioactive materials in the St. Petersburg region (Russia)

    International Nuclear Information System (INIS)

    Guskov, V.D.; Korotkov, G.V.; Drozdov, V.P.; Ershov, V.N.; Yanovskaya, N.S.

    2001-01-01

    The paper describes the test facility located near St. Petersburg (Russia) where test of packagings of mass up to 140 tons are carried out. The results of tests of some new designs of packaging for irradiated nuclear fuel are briefly considered. (author)

  6. Process control and dosimetry in a multipurpose irradiation facility

    Science.gov (United States)

    Cabalfin, E. G.; Lanuza, L. G.; Solomon, H. M.

    1999-08-01

    Availability of the multipurpose irradiation facility at the Philippine Nuclear Research Institute has encouraged several local industries to use gamma radiation for sterilization or decontamination of various products. Prior to routine processing, dose distribution studies are undertaken for each product and product geometry. During routine irradiation, dosimeters are placed at the minimum and maximum dose positions of a process load.

  7. TRIGA out of core gamma irradiation facility

    International Nuclear Information System (INIS)

    Rant, J.; Pregl, G.

    1988-01-01

    A possibility to irradiate extended objects in a gamma field inside the shielding water tank and above the core of operating TRIGA Mark II Reactor has been investigated. The irradiation cask is shielded with Cd cover to filter out thermal neutrons. The dose rate of the gamma field strongly depends on the distance of the irradiation position above the core. At 25 cm above the core, the gamma dose rate is 2.2 Gy/s and epithermal neutron flux is ∼ 8.10 6 ncm -2 s -1 ∼ 3 as measured by TLD (CaF 2 : Mn) dosimeters and Au foils respectively. Tentative applications of the gamma irradiation facility are in the studies of radiation induced accelerated aging and within the Nuclear Power Plant Equipment Qualification Program (EQP). A complete characterization of the neutron spectrum and optimization of the 7 radiation field within the cask has still to be performed. (author)

  8. Determination of proton and neutron spectra in the LANSCE spallation irradiation facility

    International Nuclear Information System (INIS)

    James, M.R.; Maloy, S.A.; Sommer, W.F.; Fowler, M.M.; Dry, D.; Ferguson, P.D.; Mueller, G.; Corzine, R.K.

    1999-01-01

    Materials samples were recently irradiated in the Los Alamos Radiation Effects Facility (LASREF) at the Los Alamos Neutron Science Center (LANSCE) to provide data for the Accelerator Production of Tritium (APT) project on the effect of irradiation on the mechanical and physical properties of materials. The targets were configured to expose samples to a variety of radiation environments including, high-energy protons, mixed protons and high-energy neutrons, and low-energy neutrons. The samples were irradiated for approximately six months during a ten month period using an 800 MeV proton beam with a circular Gaussian shape of approximately 2σ = 3.0 cm. At the end of this period, the samples were extracted and tested. Activation foils were also extracted that had been placed in proximity to the materials samples. These were used to quantify the fluences in various locations

  9. Neutron Irradiation Tests of Calibrated Cryogenic Sensors at Low Temperatures

    CERN Document Server

    Junquera, T; Thermeau, J P; Casas-Cubillos, J

    1998-01-01

    This paper presents the advancement of a program being carried out in view of selecting the cryogenic temperature sensors to be used in the LHC accelerator. About 10,000 sensors will be installed around the 26.6 km LHC ring, and most of them will be exposed to high radiation doses during the accelerator lifetime. The following thermometric sensors : carbon resistors, thin films, and platinum resistors, have been exposed to high neutron fluences (>10$^15$ n/cm$^2$) at the ISN (Grenoble, France) Cryogenic Irradiation Test Facility. A cryostat is placed in a shielded irradiation vault where a 20 MeV deuteron beam hits a Be target, resulting in a well collimated and intense neutron beam. The cryostat, the on-line acquisition system, the temperature references and the main characteristics of the irradiation facility are described. The main interest of this set-up is its ability to monitor online the evolution of the sensors by comparing its readout with temperature references that are in principle insensitive to t...

  10. Simulation of the fusion materials irradiation test facility lithium and heat transport systems for abnormal events study

    International Nuclear Information System (INIS)

    Carlson, W.F.; Elyashar, N.N.

    1981-01-01

    A digital computer model of Fusion Materials Irradiation Test Facility's heat transport system has been developed. The model utilizes a set of coupled differential equations to simulate the dynamic behavior of the primary and secondary heat transport loop systems. The model has been used to investigate the stability of the proposed control schemes for lithium temperature and flow rate and for an extensive study of equipment failures and malfunction analysis. It was determined that certain equipment failures and malfunctions in the primary loop require a response from the control system within less than one second of the occurrence of the failure. The effects of equipment failures in the secondary loop were found to be less dramatic than the equivalent failures in the primary loop. The failures in the secondary loop generally required control action in time frames of the order of minutes

  11. Accelerated radiation damage test facility using a 5 MV tandem ion accelerator

    International Nuclear Information System (INIS)

    Wady, P.T.; Draude, A.; Shubeita, S.M.; Smith, A.D.; Mason, N.; Pimblott, S.M.; Jimenez-Melero, E.

    2016-01-01

    We have developed a new irradiation facility that allows to perform accelerated damage tests of nuclear reactor materials at temperatures up to 400 °C using the intense proton (<100 μA) and heavy ion (≈10 μA) beams produced by a 5 MV tandem ion accelerator. The dedicated beam line for radiation damage studies comprises: (1) beam diagnosis and focusing optical components, (2) a scanning and slit system that allows uniform irradiation of a sample area of 0.5–6 cm"2, and (3) a sample stage designed to be able to monitor in-situ the sample temperature, current deposited on the sample, and the gamma spectrum of potential radio-active nuclides produced during the sample irradiation. The beam line capabilities have been tested by irradiating a 20Cr–25Ni–Nb stabilised stainless steel with a 3 MeV proton beam to a dose level of 3 dpa. The irradiation temperature was 356 °C, with a maximum range in temperature values of ±6 °C within the first 24 h of continuous irradiation. The sample stage is connected to ground through an electrometer to measure accurately the charge deposited on the sample. The charge can be integrated in hardware during irradiation, and this methodology removes uncertainties due to fluctuations in beam current. The measured gamma spectrum allowed the identification of the main radioactive nuclides produced during the proton bombardment from the lifetimes and gamma emissions. This dedicated radiation damage beam line is hosted by the Dalton Cumbrian Facility of the University of Manchester.

  12. Simulated Irradiation of Samples in HFIR for use as Possible Test Materials in the MPEX (Material Plasma Exposure Experiment) Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Ronald James [ORNL; Rapp, Juergen [ORNL

    2014-01-01

    The importance of Plasma Material Interaction (PMI) is a major concern in fusion reactor design and analysis. The Material-Plasma Exposure eXperiment (MPEX) facility will explore PMI under fusion reactor plasma conditions. Samples with accumulated displacements per atom (DPA) damage produced by irradiations in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) will be studied in the MPEX facility. The project presented in this paper involved performing assessments of the induced radioactivity and resulting radiation fields of a variety of potential fusion reactor materials. The scientific code packages MCNP and SCALE were used to simulate irradiation of the samples in HFIR; generation and depletion of nuclides in the material and the subsequent composition, activity levels, gamma radiation fields, and resultant dose rates as a function of cooling time. These state-of-the-art simulation methods were used in addressing the challenge of the MPEX project to minimize the radioactive inventory in the preparation of the samples for inclusion in the MPEX facility.

  13. Development of a Device for a Material Irradiation Test in the OR Test Hole

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Kang, Y. H.; Kim, B. G.; Choo, K. N.; Sohn, J. M.; Shin, Y. T.; Park, S. J.; Seo, C. K

    2008-05-15

    To develop a technology and a device for the irradiation test for utilization of the OR/IP holes according to the various requirements of users, the properties of the OR/IP holes were investigated and an irradiation device for the OR hole was designed and fabricated. The OR-4, 5 and the IP-9, 10, 11 holes were selected as those suitable to irradiation tests among the test holes located in the out core area. The conceptual design was performed to design a device to irradiate materials using the OR and IP holes. The capsule for the OR holes is fixed by pressing the protection tube using a clamping device, on the other hand the IP capsule is inserted in the hole without a special clamping device. In the basic design of the irradiation device for the OR hole, the capsules having the outside diameter of 50, 52, 54, 56mm were reviewed theoretically to investigate if they meet the hydraulic and vibration conditions required in the HANARO. The results of the pressure drop test showed that the 3 kinds of capsules having diameter of 52, 54, 56mm satisfied the requirement for the pressure difference and flow rate in HANARO. The capsule of {phi}56mm out of the above three satisfied the vibration condition and was finally selected giving consideration of a capacity of specimens. The capsule having a diameter of {phi}56mm was fabricated and the flow rate was measured. Using the velocity data measured at the out-core facility, the heat transfer coefficient, and the temperature on the surface of the capsule was evaluated to confirm it less than the ONB temperature. As a result, the capsule of {phi}56mm was selected for the irradiation test at the OR holes.

  14. Development of Pneumatic Transfer Irradiation Facility (PTS no.2) for Neutron Activation Analysis at HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Kim, S. H.; Sun, G. M.; Baek, S. Y.; Kim, H. R.; Kim, Y. J

    2008-03-15

    A pneumatic transfer irradiation system (PTS) is one of the most important facilities used during neutron irradiation of a target material for instrumental neutron activation analysis (INAA) in a research reactor. In particular, a fast pneumatic transfer system is essential for the measurement of a short half-life nuclide and a delayed neutron counting system. The pneumatic transfer irradiation system (PTS no.2) involving a manual system and an automatic system for delayed neutron activation analysis (DNAA) were reconstructed with new designs of a functional improvement at the HANARO research reactor in 2006. In this technical report, the conception, design, operation and control of PTS no.2 was described. Also the experimental results and the characteristic parameters measured by a mock-up test, a functional operation test and an irradiation test of these systems, such as the transfer time of irradiation capsule, automatic operation control by personal computer, delayed neutron counting system, the different neutron flux, the temperature of the irradiation position with an irradiation time, the radiation dose rate when the rabbit is returned, etc. are reported to provide a user information as well as a reactor's management and safety.

  15. HRB-22 capsule irradiation test for HTGR fuel. JAERI/USDOE collaborative irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Minato, Kazuo; Sawa, Kazuhiro; Fukuda, Kousaku [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; and others

    1998-03-01

    As a JAERI/USDOE collaborative irradiation test for high-temperature gas-cooled reactor fuel, JAERI fuel compacts were irradiated in the HRB-22 irradiation capsule in the High Flux Isotope Reactor at the Oak Ridge National Laboratory (ORNL). Postirradiation examinations also were performed at ORNL. This report describes 1) the preirradiation characterization of the irradiation samples of annular-shaped fuel compacts containing the Triso-coated fuel particles, 2) the irradiation conditions and fission gas releases during the irradiation to measure the performance of the coated particle fuel, 3) the postirradiation examinations of the disassembled capsule involving visual inspection, metrology, ceramography and gamma-ray spectrometry of the samples, and 4) the accident condition tests on the irradiated fuels at 1600 to 1800degC to obtain information about fuel performance and fission product release behavior under accident conditions. (author)

  16. Gas Test Loop Facilities Alternatives Assessment Report Rev 1

    International Nuclear Information System (INIS)

    William J. Skerjanc; William F. Skerjanc

    2005-01-01

    An important task in the Gas Test Loop (GTL) conceptual design was to determine the best facility to serve as host for this apparatus, which will allow fast-flux neutron testing in an existing nuclear facility. A survey was undertaken of domestic and foreign nuclear reactors and accelerator facilities to arrive at that determination. Two major research reactors in the U.S. were considered in detail, the Advanced Test Reactor (ATR) and the High Flux Isotope Reactor (HFIR), each with sufficient power to attain the required neutron fluxes. HFIR routinely operates near its design power limit of 100 MW. ATR has traditionally operated at less than half its design power limit of 250 MW. Both of these reactors should be available for at least the next 30 years. The other major U.S. research reactor, the Missouri University Research Reactor, does not have sufficient power to reach the required neutron flux nor do the smaller research reactors. Of the foreign reactors investigated, BOR-60 is perhaps the most attractive. Monju and BN 600 are power reactors for their respective electrical grids. Although the Joyo reactor is vigorously campaigning for customers, local laws regarding transport of radioactive material mean it would be very difficult to retrieve test articles from either Japanese reactor for post irradiation examination. PHENIX is scheduled to close in 2008 and is fully booked until then. FBTR is limited to domestic (Indian) users only. Data quality is often suspect in Russia. The only accelerator seriously considered was the Fuel and Material Test Station (FMTS) currently proposed for operation at Los Alamos National Laboratory. The neutron spectrum in FMTS is similar to that found in a fast reactor, but it has a pronounced high-energy tail that is atypical of fast fission reactor spectra. First irradiation in the FMTS is being contemplated for 2008. Detailed review of these facilities resulted in the recommendation that the ATR would be the best host for the GTL

  17. Fast Flux Test Facility interim examination and maintenance cell - past, present, and future

    International Nuclear Information System (INIS)

    Vincent, J.R.

    1990-01-01

    The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell was designed to perform interim examination and/or disassembly of experimental core components for final analysis elsewhere, as well as maintenance of sodium-wetted or neutron-activated internal reactor parts and plant support hardware. The first 10 yr of operation were mainly devoted to the disassembly and examination of core component test assemblies. While some maintenance was performed on reactor support equipment, such as the closed-loop ex-vessel machine (CLEM) sodium-wetted grapple, 90% of IEM cell availability has been devoted to core component tests. Some test assemblies originally considered for processing in the IEM cell have not been irradiated; others, not originally planned, have been designed, irradiated, and processed. While no major reactor equipment has required remote repair or maintenance, the IEM cell has served as the remote repair facility for its own in-cell equipment, and several innovative remote repairs have been accomplished and are described

  18. Remote handling features of the Fusion Materials Irradiation Test (FMIT) facility

    International Nuclear Information System (INIS)

    Klos, D.B.; Wierman, R.W.; Kelly, V.P.; Yount, J.A.

    1980-01-01

    Initial design of the experimental system provided two modes of access to the test cells. The horizontal mode was the predominant one. However, as the design progressed unacceptable risks were identified that increased personnel exposure to radiation and decreased testing availability of the facility. Consequently, vertical-only access was adopted. Remote handling features of both design concepts are described including the technical basis for the transition from the first to the second concept

  19. Calculation of damage function of Al{sub 2}O{sub 3} in irradiation facilities for fusion reactor applications

    Energy Technology Data Exchange (ETDEWEB)

    Mota, F., E-mail: fernando.mota@ciemat.es [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, 28040 Madrid (Spain); Ortiz, C.J., E-mail: christophe.ortiz@ciemat.es [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, 28040 Madrid (Spain); Vila, R., E-mail: rafael.vila@ciemat.es [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, 28040 Madrid (Spain); Casal, N., E-mail: natalia.casal@ciemat.es [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, 28040 Madrid (Spain); García, A., E-mail: angela.garcia@ciemat.es [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, 28040 Madrid (Spain); Ibarra, A., E-mail: Angel.ibarra@ciemat.es [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, 28040 Madrid (Spain)

    2013-11-15

    A rigorous material testing program is essential for the development of the nuclear fusion world program. In particular, it is very important to predict the generation of the displacement damage in materials, because the irradiation intensity expected in fusion conditions is such that the performance of materials and components under these extreme conditions is unknown. To study the damage produced by neutrons in materials of interest for fusion, a specific computational methodology was developed. Neutron fluxes expected in different irradiation facilities (International Fusion Materials Irradiation Facility [IFMIF] and DEMO-HCLL) and in different irradiation spots were obtained with particles transport codes (McDeLicious, MCNP). The energy differential cross sections of primary knock-on atoms were calculated using the NJOY code. Resulting data were input into the Monte Carlo code MARLOWE to calculate the corresponding displacements (i.e., interstitials (I) and vacancies (V)). However, the number of Frenkel pairs created during irradiation strongly depends on the recombination radius between interstitials and vacancies. This parameter corresponds to the minimum distance below which instantaneous recombination occurs. Mainly, the influence of such parameter on the damage function in Al{sub 2}O{sub 3} was assessed in this report. The displacements per atom values calculated as a function of the recombination radius considered are compared to experimental data to determine the most appropriate capture radius. In addition, the damage function and damage dose generated at different experimental irradiation facilities are compared with those expected in DEMO. The conclusion is that both IFMIF and TechnoFusión (future triple beam ion accelerator to emulate fusion neutron irradiation effects in materials) facilities are suited to perform relevant irradiation experiments for the design of DEMO.

  20. HFR irradiation testing of fusion materials

    International Nuclear Information System (INIS)

    Conrad, R.; von der Hardt, P.; Loelgen, R.; Scheurer, H.; Zeisser, P.

    1984-01-01

    The present and future role of the High Flux Reactor Petten for fusion materials testing has been assessed. For practical purposes the Tokamak-based fusion reactor is chosen as a point of departure to identify material problems and materials data needs. The identification is largely based on the INTOR and NET design studies, the reported programme strategies of Japan, the U.S.A. and the European Communities for technical development of thermonuclear fusion reactors and on interviews with several experts. Existing and planned irradiation facilities, their capabilities and limitations concerning materials testing have been surveyed and discussed. It is concluded that fission reactors can supply important contributions for fusion materials testing. From the point of view of future availability of fission testing reactors and their performance it appears that the HFR is a useful tool for materials testing for a large variety of materials. Prospects and recommendations for future developments are given

  1. Preliminary irradiation test results from the Yankee Atomic Electric Company reactor vessel test irradiation program

    International Nuclear Information System (INIS)

    Biemiller, E.C.; Fyfitch, Stephen; Campbell, C.A.

    1994-01-01

    The Yankee Atomic Electric Company test irradiation program was implemented to characterize the irradiation response of representative Yankee Rowe reactor vessel beltline plate materials and to remove uncertainties in the analysis of existing irradiation data on the Yankee Rowe reactor vessel steel. Plate materials each containing 0.24 w/o copper, but different nickel contents at 0.63 w/o and 0.19 w/o, were heat treated to simulate the Yankee vessel heat treatment (austenitized at 982 o C (1800 o F)) and to simulate Regulatory Guide 1.99 database materials (austenitized at 871 o C (1600 o F)). These heat treatments produced different microstructures so the effect of microstructure on irradiation damage sensitivity could be tested. Because the nickel content of the test plates varied and the copper level was constant, the effect of nickel on irradiation embrittlement was also tested. Correlation monitor material, HSST-02, was included in the program to benchmark the Ford Nuclear Reactor (University of Michigan Test Reactor) which had never been used before for this type of irradiation program. Materials taken from plate surface locations (versus 1/4 T) were included to test whether or not the improved toughness properties of the plate surface layer, resulting from the rapid quench, are maintained after irradiation. If the improved properties are maintained, pressurized thermal shock calculations could utilize this margin. Finally, for one experiment, irradiations were conducted at two irradiation temperatures (260 o C and 288 o C) to determine the effect of irradiation temperature on embrittlement. (Author)

  2. Large-scale Samples Irradiation Facility at the IBR-2 Reactor in Dubna

    CERN Document Server

    Cheplakov, A P; Golubyh, S M; Kaskanov, G Ya; Kulagin, E N; Kukhtin, V V; Luschikov, V I; Shabalin, E P; León-Florián, E; Leroy, C

    1998-01-01

    The irradiation facility at the beam line no.3 of the IBR-2 reactor of the Frank Laboratory for Neutron Physics is described. The facility is aimed at irradiation studies of various objects with area up to 800 cm$^2$ both at cryogenic and ambient temperatures. The energy spectra of neutrons are reconstructed by the method of threshold detector activation. The neutron fluence and $\\gamma$ dose rates are measured by means of alanine and thermoluminescent dosimeters. The boron carbide and lead filters or $(n/\\gamma)$ converter provide beams of different ratio of doses induced by neutrons and photons. For the lead filter, the flux of fast neutrons with energy more than 0.1 MeV is $1.4 \\cdot 10^{10}$ \\fln and the neutron dose is about 96\\% of the total radiation dose. For the $(n/\\gamma)$ converter, the $\\gamma$ dose rate is $\\sim$500 Gy h$^{-1}$ which is about 85\\% of the total dose. The radiation hardness tests of GaAs electronics and materials for the ATLAS detector to be put into operation at the Large Hadron ...

  3. Upgrade to the Birmingham Irradiation Facility

    CERN Document Server

    Dervan, P; Hodgson, P; Marin- Reyes; Parker, K; Wilson, J; Baca, M

    2015-01-01

    The Birmingham Irradiation Facility was developed in 2013 at the University of Birmingham using the Medical Physics MC40 cyclotron. It can achieve High Luminosity LHC (HL-LHC) fluences of 10^15 (1 MeV neutron equivalent (neq)) cm^-2 in 80 s with proton beam currents of 1 μA and so can evaluate effectively the performance and durability of detector technologies and new components to be used for the HL-LHC. Irradiations of silicon sensors and passive materials can be carried out in a temperature controlled cold box which moves continuously through the homogenous beamspot. This movement is provided by a pre-configured XY-axis Cartesian robot scanning system. In 2014 the cooling system and cold box were upgraded from a recirculating glycol chiller system to a liquid nitrogen evaporative system. The new cooling system achieves a stable temperature of 50 1C in 30 min and aims to maintain sub-0 1C temperatures on the sensors during irradiations. This paper reviews the design, development, commissioning and perform...

  4. Testing of neutron-irradiated ceramic-to-metal seals

    International Nuclear Information System (INIS)

    Brown, R.D.; Clinard, F.W. Jr.; Lopez, M.R.; Martinez, H.; Romero, T.J.; Cook, J.H.; Barr, H.N.; Hittman, F.

    1990-01-01

    This paper reports on ceramic-to-metal seals prepared by sputtering a titanium metallizing layer onto ceramic disks and then brazing to metal tubes. The ceramics used were alumina, MACOR, spinel, AlON, and a mixture of Al 2 O 3 and Si 3 N 4 . Except for the MACOR, which was brazed to a titanium tube, the ceramics were brazed to niobium tubes. The seals were leak tested and then sent to Los Alamos National Laboratory, where they were irradiated using the spallation neutron source at the Los Alamos Meson Physics Facility. Following irradiation for ∼ 90 days to a fluence of 2.8 x 10 23 n/m 2 , the samples were moved to hot cells and again leak tested. Only the MACOR samples showed any measurable leaks. One set of samples was then pressurized to 6.9 MPa (1000 psi) and subsequently leak tested. No leaks were found. Bursting the seals required hydrostatic pressures of at least 34 MPa (5000 psi). The high seal strength and few leaks indicate that ceramic-to-metal seals can resist radiation-induced degradation

  5. Vibration test report on the instrumented capsule for fuel irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, D. B.; Wu, J. S.; Oh, J. M.; Park, S. J.; Cho, M. S.; Kim, B. G.; Kang, Y. W

    2003-01-01

    The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the natural frequency components near 7.5Hz and 17.5Hz were dominant in the fluid-induced vibration signal. The maximum amplitude of the accelerations was measured as 12.04m/s{sup 2} that is within the allowable vibrational limit(18.99m/s{sup 2})of the reactor structure. Also, the maximum displacement amplitude was calculated as 0.191mm. Since these vibration levels are remarkably low, excessive vibration is not expected when the irradiation test of the instrumented capsule is performed at the HANARO core.

  6. Development of Pneumatic Transfer Irradiation Facility (PTS no.1) for Neutron Activation Analysis at HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Kim, S. H.; Sun, G. M.; Baek, S. Y.; Kim, H. R.; Kim, Y. J

    2008-03-15

    A pneumatic transfer system (PTS) is one of the most important facilities used during neutron irradiation of a target material for instrumental neutron activation analysis (INAA) in a research reactor. In particular, a fast pneumatic transfer system is essential for the measurement of a short half-life nuclide and a delayed neutron counting system. The pneumatic transfer system (PTS no.1) involving a manual system and an semiautomatic system were reconstructed with new designs of a functional improvement at the HANARO research reactor in 2006. In this technical report, the conception, design, operation and control of these system (PTS no.1) was described. Also the experimental results and the characteristic parameters measured by a mock-up test, a functional operation test and an irradiation test of these systems, such as the transfer time of irradiation capsule, the different neutron flux, the temperature of the irradiation position with an irradiation time, the radiation dose rate when the rabbit is returned, etc. are reported to provide a user information as well as a reactor's management and safety.

  7. Irradiation effects test series test IE-1 test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.; Mehner, A.S.

    1977-03-01

    The report describes the results of the first programmatic test in the Nuclear Regulatory Commission Irradiation Effects Test Series. This test (IE-1) used four 0.97m long PWR-type fuel rods fabricated from previously irradiated Saxton fuel. The objectives of this test were to evaluate the effect of fuel pellet density on pellet-cladding interaction during a power ramp and to evaluate the influence of the irradiated state of the fuel and cladding on rod behavior during film boiling operation. Data are presented on the behavior of irradiated fuel rods during steady-state operation, a power ramp, and film boiling operation. The effects of as-fabricated gap size, as-fabricated fuel density, rod power, and power ramp rate on pellet-cladding interaction are discussed. Test data are compared with FRAP-T2 computer model predictions, and comments on the consequences of sustained film boiling operation on irradiated fuel rod behavior are provided

  8. Progress in developing the concept for the irradiation research facility

    International Nuclear Information System (INIS)

    Lee, A.G.; Bishop, W.E.; Gillespie, G.E.; Zeng, Y.

    1996-04-01

    At the 16th annual Canadian Nuclear Society conference, AECL presented the case for replacing the NRU reactor with an Irradiation Research Facility (IRF) to test CANDU fuels and materials and to perform advanced materials research using neutrons. AECL developed a cost estimate of $500 million for the reference IRF concept, and estimated that it would require 87 months to complete. AECL has initiated a pre-project program to develop the IRF concept and to minimize uncertainties related to feasibility and licensability, and to examine options for reducing the overall project cost before project implementation begins. (author) 10 refs., 2 figs

  9. Planning a 60Co irradiation facility for fruit preservation

    International Nuclear Information System (INIS)

    Yuan, H.C.

    1978-01-01

    A conceptual design for a conveyor system is proposed for use in fruit irradiation. The seasonal nature of the fruit harvest requires that the 60 Co source inventory should be sufficient to meet the demand at peak season, but this would be excessive at the beginning and towards the end of the harvest. Because of the short crop period the possibility of other irradiation services should be exploited to ensure full utilization of the facility. For successful extension of fruit shelf-life rigid practices in pre-irradiation treatment are essential and careful packaging is indispensable to the operation of the irradiator. Based on the time required for construction and equipment supply, a period of 18 months should be assumed for completion of the project. (author)

  10. Gamma irradiation facilities for radiation tolerance assessment of components and systems at SCK.CEN

    International Nuclear Information System (INIS)

    Coenen, S.; Decreton, M.

    1999-01-01

    This paper presents the different gamma irradiation facilities available at SCK-CEN (Mol, Belgium). With gamma dose rates ranging from 1 Gy/h up to 50 kGy/h, extensive environmental control and on-line instrumentation possibilities, they offer ideal test environments for the radiation tolerance assessment of components and systems for many applications where radiation tolerance is a concern. (authors)

  11. Single Event Effects Test Facility Options at the Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Riemer, Bernie [ORNL; Gallmeier, Franz X [ORNL; Dominik, Laura J [ORNL

    2015-01-01

    Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of integrated circuits (ICs) and systems for use in radiation environments requires the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.

  12. Calculation of displacement and helium production at the Clinton P. Anderson Los Alamos Meson Physics Facility (LAMPF) irradiation facility

    International Nuclear Information System (INIS)

    Wechsler, M.S.; Davidson, D.R.; Greenwood, L.R.; Sommer, W.F.

    1984-01-01

    CT: Differential and total displacement and helium production rates are calculated for copper irradiated by spallation neutrons and 760 MeV protons at the Clinton P. Anderson Los Alamos Meson Physics Facility (LAMPF). The calculations are performed using the SPECTER and VNMTC computer codes, the latter being specially designed for spallation radiation damage calculations. For comparison, similar SPECTER calculations are also described for irradiation of copper in EBR-II and RTNS-II. The results indicate substantial contributions to the displacement and helium production rates due to neutrons in the high-energy tail (above 20 MeV) of the LAMPF spallation neutron spectrum. Still higher production rates are calculated for irradiations in the direct proton beam. These results will provide useful background information for research to be conducted at a new irradiation facility at LAMPF

  13. Re-irradiation tests of spent fuel at JMTR by means of re-instrumentation technique

    International Nuclear Information System (INIS)

    Nakamura, Jinichi; Shimizu, Michio; Endo, Yasuichi; Nabeya, Hideaki; Ichise, Kenichi; Saito, Junichi; Oshima, Kunio; Uetsuka, Hiroshi

    1999-01-01

    JAERI has developed re-irradiation test procedures of spent fuel irradiated at commercial reactor by means of re-instrumentation technique. Full length rods irradiated at commercial LWRs were re-fabricated to short length rods, and rod inner pressure gauges and fuel center thermocouples were re-instrumented to the rods. Re-irradiation tests to study the fuel behavior during power change were carried out by means of BOCA/OSF-1 facility at the JMTR. In the tests to study the fission gas release during power change, the rod inner pressure increase was observed during power change, especially during power reduction. The fission gas release during power reduction is estimated to be the release from fission gas bubbles on the grain boundary caused by the thermal stress in the pellet during power reduction. Re-irradiation test of gadolinia added fuel was performed by means of dual re-instrumentation technique (fuel center thermocouples and rod inner pressure gauge). A stepwise fission gas release during power change, and the following fuel center temperature change due to gap conductance change were observed. (author)

  14. Proceedings of 1991-workshops of the working group on 'Development and application of facilities for low temperature irradiation as well as controlled irradiation'

    International Nuclear Information System (INIS)

    Kuramoto, Eiichi; Okada, Moritami

    1992-09-01

    This is the proceedings of 1991-workshops of the working group on 'Development and Application of Facilities for Low Temperature Irradiation as well as Controlled Irradiation' held at the Research Reactor Institute of Kyoto University on July 25, 1991 and on February 28, 1992. In the present proceedings, it is emphasized that the study of radiation damages in various materials must be performed under carefully controlled irradiation conditions (irradiation temperature, neutron spectrum and so forth) during reactor irradiations. Especially, it is pointed out that a middle scale reactor such as KUR is suitable for the precise control of neutron spectra. Several remarkable results, which are made through experiments using the Low Temperature Irradiation Facility in KUR (KUR-LTL), are reported. Also, possible advanced research programs are discussed including the worldwide topics on the radiation damages in metals, semi-conductors and also insulators. Further, the present status of KUR-LTL is reported and the advanced plan of the facility is proposed. (author)

  15. CONTRIBUTION OF HANARO IRRADIATION TECHNOLOGIES TO NATIONAL NUCLEAR R&D

    Directory of Open Access Journals (Sweden)

    KEE NAM CHOO

    2014-08-01

    Full Text Available HANARO is a multipurpose research reactor located at the Korea Atomic Energy Research Institute (KAERI. Since the commencement of its operation in 1995, various neutron irradiation facilities, such as rabbit irradiation facilities, fuel test loop (FTL facilities, capsule irradiation facilities, and neutron transmutation doping (NTD facilities, have been developed and actively utilized for various nuclear material irradiation tests requested by users from research institutes, universities, and industries. Most irradiation tests have been related to national R&D relevant to present nuclear power reactors such as the ageing management and safety evaluation of the components. Based on the accumulated experience as well as the sophisticated requirements of users, HANARO has recently supported national R&D projects relevant to new nuclear systems including the System-integrated Modular Advanced Reactor (SMART, research reactors, and future nuclear systems. This paper documents the current state and utilization of irradiation facilities in HANARO, and summarizes ongoing research efforts to deploy advanced irradiation technology.

  16. Development of Pneumatic Transfer Irradiation Facility (PTS no.3) for Neutron Activation Analysis at HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Kim, S. H.; Sun, G. M.; Baek, S. Y.; Kim, H. R.; Kim, Y. J

    2008-04-15

    A pneumatic transfer system (PTS) is one of the most important facilities used during neutron irradiation of a target material for instrumental neutron activation analysis (INAA) in a research reactor. In particular, a fast pneumatic transfer system is essential for the measurement of a short half-life nuclide. The pneumatic transfer irradiation system (PTS no.3) involving a manual system and an semi-automatic system were reconstructed with new designs of a functional improvement at the HANARO research reactor and NAA laboratory of RI building in 2006. In this technical report, the design, operation and control of these system (PTS no.3) was described. Also the experimental results and the characteristic parameters measured from a functional operation test and an irradiation test of these systems, such as the transfer time of irradiation capsule, the different neutron flux, the temperature of the irradiation position with an irradiation time, the radiation dose rate when the rabbit is returned, etc. are reported to provide a user information as well as a reactor's management and safety.

  17. Breathing new life into your production irradiator the case for reinvesting in your facility

    International Nuclear Information System (INIS)

    Aube, Robert; Wynnyk, Mike

    2002-01-01

    This paper focuses on one of the important technology issues facing the gamma processing industry today: that of strategically planning for extending the useful life of a production irradiator. Production irradiator owners are typically faced with the difficult question of whether or not to significantly reinvest in their facilities after 15-20 years of service. At this point in time the irradiator has likely provided many years of safe, reliable service and has paid for itself many times over. As the equipment ages, it may become less reliable, due to wear and maintenance practices, and more costly to operate. The cost of refurbishing the equipment may be significant and the downtime required to complete the refurbishment is also likely to be a challenge. This makes it essential to present a clear and rational justification for reinvesting in the facility. There has been a growing trend in recent years for irradiator owners to refurbish or upgrade their facilities. This trend is driven by the need to keep the facilities operating efficiently and safely as well as by the desire to take advantage of advancements that have occurred in the technology over the years. These advancements can enhance equipment efficiency, improve operational effectiveness and maintain or exceed quality assurance requirements. This paper illustrates the value of reinvesting in irradiator facilities, and highlights the significant benefits derived

  18. Development of lithium target system in engineering validation and engineering design activity of the international fusion materials irradiation facility (IFMIF/EVEDA)

    International Nuclear Information System (INIS)

    Wakai, Eiichi; Kondo, Hiroo; Sugimoto, Masayoshi; Ida, Mizuho; Kanemura, Takuji; Watanabe, Kazuyoshi; Fujishiro, Kouji; Edao, Yuuki; Niitsuma, Shigeto; Kimura, Haruyuki; Fukada, Satoshi; Hiromoto, Tetsushi; Shigeharu, Satoshi; Yagi, Jyuro; Furukawa, Tomohiro; Hirakawa, Yasushi; Suzuki, Akihiro; Terai, Takayuki; Horiike, Hiroshi; Hoashi, Eiji; Suzuki, Sachiko; Yamaoka, Nobuo; Serizawa, Hisashi; Kawahito, Yosuke; Tsuji, Yoshiyuki; Furuya, Kazuyuki; Takeo, Fumio

    2012-01-01

    Engineering validation and engineering design activity (EVEDA) for the international fusion materials irradiation facility (IFMIF) has been conducted since 2007. Research and development of the Lithium target facility is an important part of this activity. We constructed a world largest liquid Lithium test loop with a capacity of 5000 L in 2010 and successfully completed the first stage validation tests (functional tests of components and Lithium flow test (flow velocity 15 m/s at the target). In the present article, recent results of the EVEDA activity for the Lithium target facility and related technologies on liquid Lithium are reviewed. (author)

  19. Development of the irradiation facilities for silicon neutron doping in France

    International Nuclear Information System (INIS)

    Breant, P.; Cherruau, F.; Genthon, J.P.

    1980-08-01

    Irradiation facilities for silicon irradiations in France may be classified in two categories: on the one hand the devices directly implemented in the light water of α swimming-pool reactor and on the other hand the devices implemented in a neutronic medium -heavy water here- providing a high value of the thermal to fast neutron flux ratio. The tools used in France for silicon neutron doping are recapitulated according to this classification in tables, with their main characteristics; in addition it is specified that all existing facilities are instrumented with ingot rotation, flux monitoring, automatic time integration and are associated with handling, storage, cleaning, decontamination and activity control equipment. Finally, concerning the irradiation capacities given in these tables, it is pointed out that they are realistic and present capacities, for presently running devices and according to the way they are used on an average; that is to say that they take into account the real average dimensions of the ingot supplied and not the maximum possible loading with the maximum diameters. Further extensions of capacity are possible if need be by the installation of supplementary standard irradiation modules in the pools. Particular attention will given to the new developments: -new irradiaton facilities with a high Oth/Or ratio being developed in the new research reactor ORPHEE: - developments in the OSIRIS H 2 O reactor. In particular and in connection with the facilities developped in OSIRIS, neutronic problems typical and swimming-pool reactors will be contemplated and the adopted solutions given

  20. Testing capabilities of Los Alamos National Laboratory for irradiated materials

    International Nuclear Information System (INIS)

    Maloy, S.A.; James, M.R.; Sommer, W.F.

    1999-01-01

    Spallation neutron sources expose materials to high energy (>100 MeV) proton and neutron spectra. Although numerous studies have investigated the effects of radiation damage in a lower energy neutron flux from fission or fusion reactors on the mechanical properties of materials, very little work has been performed on the effects that exposure to a spallation neutron spectrum has on the mechanical properties of materials. These effects can be significantly different than those observed in a fission or fusion reactor spectrum because exposure to high energy protons and neutrons produces more He and H along with the atomic displacement damage. Los Alamos National Laboratory has unique facilities to study the effects of spallation radiation damage on the mechanical properties of materials. The Los Alamos Neutron Science Center (LANSCE) has a pulsed linear accelerator which operates at 800 MeV and 1 mA. The Los Alamos Spallation Radiation Effect Facility (LASREF) located at the end of this accelerator is designed to allow the irradiation of components in a proton beam while water cooling these components and measuring their temperature. After irradiation, specimens can be investigated at hot cells located at the Chemical Metallurgy Research Building. Wing 9 of this facility contains 16 hot cells set up in two groups of eight, each having a corridor in the center to allow easy transfer of radioactive shipments into and out of the hot cells. These corridors have been used to prepare specimens for shipment to collaborating laboratories such as PNNL, ORNL, BNL, and the Paul Scherrer Institute to perform specialized testing at their hot cells. The LANL hot cells contain capabilities for opening radioactive components and testing their mechanical properties as well as preparing specimens from irradiated components

  1. The proposed irradiation facility and applications

    International Nuclear Information System (INIS)

    Singson, C.C.; Navarro, Q.O.

    As early as 1972, the Philippine Atomic Energy Commission proposed the setting up of a radiation facility for the sterilization of medical products. A result of a market survey with the assistance of an IAEA expert was conducted to determine the market potential for such venture. With the Food Terminal, Inc. (FTI) a government agro-industrial fair which explored the economic benefits of project, encouraging results have been obtained with finances from FAO and IAEA. The proposed pilot plant will serve as a multi purpose facility for the sterilization of medical and laboratory products, irradiation of food and agricultural produce and manufacture of wood plastic compositions for the textile and furniture industries. With the benefits derived from the said project, it is hoped that its early installation be pushed through. (author)

  2. MCNPCX calculations of dose rates and spectra in experimental channels of the CTEx irradiating facility

    International Nuclear Information System (INIS)

    Gomes, Renato G.; Rebello, Wilson F.; Vellozo, Sergio O.; Junior, Luis M.; Vital, Helio C.; Rusin, Tiago; Silva, Ademir X.

    2013-01-01

    MCNPX simulations have been performed in order to calculate dose rates as well as spectra along the four experimental channels of the gamma irradiating facility at the Technology Center of the Brazilian Army (CTEx). Safety, operational and research requirements have led to the need to determine both the magnitude and spectra of the leaking gamma fluxes. The CTEx experimental facility is cavity type with a moveable set of 28 horizontally positioned rods, filled with Cesium-137 chloride and doubly encased in stainless steel that yields an approximately plane 42 kCi-source that provides a maximum dose rate of about 1.5 kG/h into two irradiating chambers. The channels are intended for irradiation tests outside facility. They would allow larger samples to be exposed to lower gamma dose rates under controlled conditions. Dose rates have been calculated for several positions inside the channels as well as at their exits. In addition, for purposes related to the safety of operators and personnel, the angles submitted by the exiting beams have also been evaluated as they spread when leaving the channels. All calculations have been performed by using a computational model of the CTEx facility that allows its characteristics and operation to be accurately simulated by using the Monte Carlo Method. Virtual dosimeters filled with Fricke (ferrous sulfate) were modeled and positioned throughout 2 vertical channels (top and bottom) and 2 horizontal ones (front and back) in order to map dose rates and gamma spectrum distributions. The calculations revealed exiting collimated beams in the order of tenths of Grays per minute as compared to the maximum 25 Gy / min dose rate in the irradiator chamber. In addition, the beams leaving the two vertical channels were found to exhibit a widespread cone-shaped distribution with aperture angle ranging around 85 deg. The data calculated in this work are intended for use in the design of optimized experiments (better positioning of samples and

  3. Postirradiation examination results for the Irradiation Effects Test 2

    International Nuclear Information System (INIS)

    Ploger, S.A.; Kerwin, D.K.; Croucher, D.W.

    1978-01-01

    This report presents the postirradiation examination results of Test IE-2 in the Irradiation Effects Test Series conducted under the Thermal Fuels Behavior Program. The objectives of this test were to evaluate the influence of previous cladding irradiation and fuel-cladding diametral gap on fuel rod behavior during a power ramp and during film boiling operation. Test IE-2, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed two 0.97-m-long pressurized water reactor type fuel rods fabricated from previously irradiated zircaloy-4 cladding and two similar rods fabricated from unirradiated cladding. The four rods were subjected to a preconditioning period, followed by a power ramp to an average peak rod power of 68 kW/m and steady state operation for one hour at an individual rod coolant mass flux of 4880 kg/s . m 2 . After a flow reduction to 2550 kg/s . m 2 , film boiling occurred on three rods. An additional flow reduction to 2245 kg/s . m 2 produced film boiling on the remaining fuel rod. Maximum time in film boiling was 90 s. None of the four fuel rods failed during the test. Damage caused by film boiling, as characterized by oxidation, oxide spalling, and collapse at fuel pellet interfaces, was found on all four rods. Film boiling regions on these rods showed evidence of fuel melting, fuel centerline void formation, and internal cladding oxidation resulting from fuel-cladding reaction. Effects of fuel-cladding diametral gap and cladding irradiation are summarized. Measured temperatures and metallographically estimated temperatures are compared at several axial fuel rod locations

  4. PSA Solar furnace: A facility for testing PV cells under concentrated solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Reche, J.; Canadas, I.; Sanchez, M.; Ballestrin, J.; Yebra, L.; Monterreal, R.; Rodriguez, J.; Garcia, G. [Concentration Solar Technologies, Plataforma Solar de Almeria-CIEMAT P.O. Box 22, Tabernas, E-04200 (Almeria) (Spain); Alonso, M.; Chenlo, F. [Photovoltaic Components and Systems, Renewable Energies Department-CIEMAT Avda. Complutense, 22, Madrid, E-28040 (Spain)

    2006-09-22

    The Plataforma Solar de Almeria (PSA), the largest centre for research, development and testing of concentration solar thermal technologies in Europe, has started to apply its knowledge, facilities and resources to development of the Concentration PV technology in an EU-funded project HiConPV. A facility for testing PV cells under solar radiation concentrated up to 2000x has recently been completed. The advantages of this facility are that, since it is illuminated by solar radiation, it is possible to obtain the appropriate cell spectral response directly, and the flash tests can be combined with prolonged PV-cell irradiation on large surfaces (up to 150cm{sup 2}), so the thermal response of the PV cell can be evaluated simultaneously. (author)

  5. Improvement of the High Fluence Irradiation Facility at the University of Tokyo

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Kenta, E-mail: murakami@tokai.t.u-tokyo.ac.jp [Nuclear Professional School, School of Engineering, The University of Tokyo, 2-22 Shirakata-Shirane, Tokai-mura, Ibaraki 319-1188 (Japan); Iwai, Takeo, E-mail: iwai@med.id.yamagata-u.ac.jp [Faculty of Medicine, Yamagata University, 2-2-2 Iida-Nishi, Yamagata, Yamagata-shi 990-9585 (Japan); Abe, Hiroaki, E-mail: abe.hiroaki@n.t.u-tokyo.ac.jp [Nuclear Professional School, School of Engineering, The University of Tokyo, 2-22 Shirakata-Shirane, Tokai-mura, Ibaraki 319-1188 (Japan); Sekimura, Naoto, E-mail: sekimura@n.t.u-tokyo.ac.jp [Department of Nuclear Engineering and Management, School of Engineering, The University of Tokyo, 7-3-1, Tokyo, Hongo, Bunkyo, 113-8656 (Japan)

    2016-08-15

    This paper reports the modification of the High Fluence Irradiation Facility at the University of Tokyo (HIT). The HIT facility was severely damaged during the 2011 earthquake, which occurred off the Pacific coast of Tohoku. A damaged 1.0 MV tandem Cockcroft-Walton accelerator was replaced with a 1.7 MV accelerator, which was formerly used in another campus of the university. A decision was made to maintain dual-beam irradiation capability by repairing the 3.75 MV single-ended Van de Graaff accelerator and reconstructing the related beamlines. A new beamline was connected with a 200 kV transmission electron microscope (TEM) to perform in-situ TEM observation under ion irradiation.

  6. A discussion on establishment of GIP management system for food irradiation facilities

    International Nuclear Information System (INIS)

    Lu Jiang; Shi Hua; Li Ruisong; Li Shurong; Zhou Hongjie; Ha Yiming

    2005-01-01

    This article analyses the hazard factors and selects Critical Control Point (CCP) for food irradiation process (including staff, facilities and processing) using HACCP version. The principles and method of GIP system for food irradiation plant are also discussed. (authors)

  7. Irradiation Test in HANARO of the Parts of an X-Gen Nuclear Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H. (and others)

    2008-08-15

    An instrumented capsule of 07M-13N was designed, fabricated and irradiated for an evaluation of the neutron irradiation properties of the parts of an X-Gen nuclear fuel assembly for PWR requested by KNF. Some specimens requested by Westinghouse Co. and Hanyang university were also inserted. 389 KNF specimens such as bucking and spring test specimens of 1x1 cell spacer grid, tensile, microstructure and tensile of welded parts, irradiation growth, spring test specimens made of HANA tube, Zirlo, Zircaloy-4, Inconel-718 were placed in the capsule. The capsule was composed of 5 stages having many kinds of specimens and an independent electric heater at each stage. During the irradiation test, the temperature of the specimens and the thermal/fast neutron fluences were measured by 14 thermocouples and 7 sets of Ni-Ti-Fe (2 sets contain additional Nb-Ag) neutron fluence monitors installed in the capsule. The capsule was irradiated for 59.19days (4 cycles) in the CT test hole of HANARO of a 30MW thermal output at 300 {approx} 420 .deg. C(for KNF specimens) up to a fast neutron fluence of 1.27x10{sup 21}(n/cm{sup 2}) (E>1MeV). After an irradiation test, the main body of the capsule was cut off at the bottom of the protection tube with a cutting system and it was transported to the IMEF (Irradiated Materials Examination Facility). The irradiated specimens were tested to evaluate the irradiation performance of the parts of an X-Gen fuel assembly in the IMEF hot cell.

  8. Facility effluent monitoring plan for the 327 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 327 Facility [Post-Irradiation Testing Laboratory] provides office and laboratory space for Pacific Northwest Laboratory (PNL) scientific and engineering staff conducting multidisciplinary research in the areas of post-irradiated fuels and structural materials. The facility is designed to accommodate the use of radioactive and hazardous materials in the conduct of these activities. This report summarizes the airborne emissions and liquid effluents and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  9. Technical review on irradiation tests and post-irradiation examinations in JMTR

    International Nuclear Information System (INIS)

    2017-07-01

    The Japan Materials Testing Reactor (JMTR) has been contributing to various R and D activities in the nuclear research such as the fundamental research of nuclear materials/ fuels, safety research and development of power reactors, radio isotope (RI) production since its beginning of the operation in 1968. Irradiation technologies and post irradiation examination (PIE) technologies are the important factors for irradiation test research. Moreover, these technologies induce the breakthrough in area of nuclear research. JMTR has been providing unique capabilities for the irradiation test research for about 40 years since 1968. In future, any needs for irradiation test research used irradiation test reactors will continue, such as R and D of generation 4 power reactors, fundamental research of materials/fuels, RI production. Now, decontamination and new research reactor construction are common issue in the world according to aging. This situation is the same in Japan. This report outlines irradiation and PIE technologies developed at JMTR in 40 years to contribute to the technology transfer and human resource development. We hope that this report will be used for the new research rector design as well as the irradiation test research and also used for the human resource development of nuclear engineers in future. (author)

  10. Rocketball Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This test facility offers the capability to emulate and measure guided missile radar cross-section without requiring flight tests of tactical missiles. This facility...

  11. Laser-Plasma Interactions on NIKE and the Fusion Test Facility

    Science.gov (United States)

    Phillips, Lee; Weaver, James

    2008-11-01

    Recent proposed designs for a Fusion Test Facility (FTF) (Obenchain et al., Phys. Plasmas 13 056320 (2006)) for direct-drive ICF targets for energy applications involve high implosion velocities combined with higher laser irradiances. The use of high irradiances increases the likelihood of deleterious laser plasma instabilities (LPI) but the proposed use of a 248 nm KrF laser to drive these targets is expected to minimize the LPI risk. We examine, using simulation results from NRL's FAST hydrocode, the proposed operational regimes of the FTF in relation to the thresholds for the SRS, SBS, and 2-plasmon instabilities. Simulations are also used to help design and interpret ongoing experiments being conducted at NRL's NIKE facility for the purpose of generating and studying LPI. Target geometries and laser pulseshapes were devised in order to create plasma conditions with long scalelengths and low electron temperatures that allow the growth of parametric instabilities. These simulations include the effects of finite beam angles through the use of raytracing.

  12. A description of the Canadian irradiation-research facility proposed to replace the NRU reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, A G; Lidstone, R F; Bishop, W E; Talbot, E F; McIlwain, H [Atomic Energy of Canada Ltd., Pinawa, MB (Canada). Whiteshell Labs.

    1996-12-31

    To replace the aging NRU reactor, AECL has developed the concept for a dual-purpose national Irradiation Research Facility (IRF) that tests fuel and materials for CANDU (CANada Deuterium Uranium) reactors and performs materials research using extracted neutron beams. The IRF includes a MAPLE reactor in a containment building, experimental facilities, and support facilities. At a nominal reactor power of 40 MW{sub t}, the IRF will generate powers up to 1 MW in natural-uranium CANDU bundles, fast-neutron fluxes up to 1.4 x 10{sup 18} n{center_dot}m{sup -2}{center_dot}s{sup -1} in Zr-alloy specimens, and thermal-neutron fluxes matching those available to the NRU beam tubes. (author). 9 refs., 5 tabs., 2 figs.

  13. Performance confirmation operation of water environment control facility

    International Nuclear Information System (INIS)

    Magome, Hirokatsu; Okada, Yuji; Tomita, Kenji; Iida, Kazuhiro; Ando, Hitoshi; Yonekawa, Akihisa; Ueda, Haruyasu; Hanawa, Hiroshi; Kanno, Masaru; Sakuta, Yoshiyuki

    2015-09-01

    In Japan Atomic Energy Agency, in order to solve the problem in the long-term operation of a light water reactor, preparation which does the irradiation experiment of light-water reactor fuel and material was advanced. JMTR stopped after the 165th operation cycle in August 2006, and is advancing renewal of the irradiation facility towards re-operation. The material irradiation test facility was installed from 2008 fiscal year to 2012 fiscal year in JMTR. The material irradiation test facility is used for IASCC study, and consists of mainly three equipments. This report described performance operating test of the water environmental control facilities for IASCC study carried out 2013 fiscal year. (author)

  14. Test and User Facilities | NREL

    Science.gov (United States)

    Test and User Facilities Test and User Facilities Our test and user facilities are available to | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z B Battery Thermal and Life Test Facility Biochemical Conversion Pilot Plant C Controllable Grid Interface Test System D Dynamometer Test Facilities

  15. Industrial gamma irradiation facility with a wet storage source in Syrian Arab Republic

    International Nuclear Information System (INIS)

    Othman, I.; Moussa, A.; Stepanov, D.G.; Ermakov, V.

    1998-01-01

    A gamma radiation facility was built in Damascus, Syria. The plant (ROBO) is a Co-60 wet storage, batch/continuous facility with nominal capacity of 1.85x10 16 Bq. The initial activity is 3.7x10 15 Bq. The ratio of maximum absorbed dose to the minimum one within irradiated materials is around 1.3+/-0.03. The irradiator consists of two sections to select required sources for irradiation. Two pools were constructed. The main pool will serve as biological shield for the main sources frame. The second pool will host a fixed circular frame to be used as calibration source or to irradiate small samples to low doses. The conveyor consists of a chain facility moving along trucks. A repair section is provided on the conveyor route in the load-unload area for carrying out inspection, repair, etc. The trucks are holed with a rectangular frames. Loading, unloading and rearrangement of the products is carried out automatically. This mechanism is carried out by seven pneumatic cylinders, lifting devices and roller conveyors. Many safety features were included: push-back platform, followed by pit used as a physical barrier. Interlocks are connected to the platform, pit cover and to ionization chambers. In case of power failure or any overriding of interlocks, the irradiator comes to emergency dropping. Ventilation system, fire system, emergency power and closed water purification system are indicated on control panel. The facility will be utilized for medical products sterilization, research and calibration

  16. CLEAR test facility

    CERN Multimedia

    Ordan, Julien Marius

    2017-01-01

    A new user facility for accelerator R&D, the CERN Linear Electron Accelerator for Research (CLEAR), started operation in August 2017. CLEAR evolved from the former CLIC Test Facility 3 (CTF3) used by the Compact Linear Collider (CLIC). The new facility is able to host and test a broad range of ideas in the accelerator field.

  17. Design and fabrication report on capsule (11M 19K for out of pile test) for irradiation testing of research reactor materials at HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Yang, S.W.; Park, S.J.; Shim, K.T.; Choo, K.N.; Oh, J.M.; Lee, B.C.; Choi, M.H.; Kim, D.J.; Kim, J.M.; Kang, S.H.; Chun, Y.B.; Kim, T.K.; Jeong, Y.H.

    2012-05-15

    As a part of the research reactor development project with a plate type fuel, the irradiation tests of graphite (Gr), beryllium (Be), and zircaloy 4 materials using the capsule have been investigating to obtain the mechanical characteristics such as an irradiation growth, hardness, swelling and tensile strength at the temperature below 100 .deg. C and the 30 MW reactor power. Then, A capsule to be able to irradiate materials(graphite, Be, zircaloy 4) under 100 .deg. C at the HANARO was designed and fabricated. After performing out of pile testing in single channel test loop by using the capsule, the final design of the capsules to be irradiated in CT and IR2 test hole of HANARO was approved, and 2 sets of capsule were fabricated. These capsules will be loaded in CT and IR2 test hole of HANARO, and be started the irradiation from the end of June, 2012. After performing the irradiation testing of 2 sets of capsule, PIE (Post Irradiation Examination) on irradiated specimens (Gr, Be, and zircaloy 4) will be carry out in IMEF (Irradiated Material Examination Facility). So, the irradiation testing will be contributed to obtain the characteristic data induced neutron irradiation on Gr, Be, and zircaloy 4. And then, it is convinced that these data will be also contributed to obtain the license for JRTR (Jordan Research and Training Reactor) and new research reactor in Korea, and export research reactors.

  18. Shear compression testing of glass-fibre steel specimens after 4K reactor irradiation: Present status and facility upgrade

    International Nuclear Information System (INIS)

    Gerstenberg, H.; Kraehling, E.; Katheder, H.

    1997-01-01

    The shear strengths of various fibre reinforced resins being promising candidate insulators for superconducting coils to be used tinder a strong radiation load, e.g. in future fusion reactors were investigated prior and subsequent to reactor in-core irradiation at liquid helium temperature. A large number of sandwich-like (steel-bonded insulation-steel) specimens representing a widespread variety of materials and preparation techniques was exposed to irradiation doses of up to 5 x 10 7 Gy in form of fast neutrons and γ-radiation. In a systematic study several experimental parameters including irradiation dose, postirradiation storage temperature and measuring temperature were varied before the determination of the ultimate shear strength. The results obtained from the different tested materials are compared. In addition an upgrade of the in-situ test rig installed at the Munich research reactor is presented, which allows combined shear/compression loading of low temperature irradiated specimens and provides a doubling of the testing rate

  19. Irradiation experiments and materials testing capabilities in High Flux Reactor in Petten

    International Nuclear Information System (INIS)

    Luzginova, N.; Blagoeva, D.; Hegeman, H.; Van der Laan, J.

    2011-01-01

    The text of publication follows: The High Flux Reactor (HFR) in Petten is a powerful multi-purpose research and materials testing reactor operating for about 280 Full Power Days per year. In combination with hot cells facilities, HFR provides irradiation and post-irradiation examination services requested by nuclear energy research and development programs, as well as by industry and research organizations. Using a variety of the custom developed irradiation devices and a large experience in executing irradiation experiments, the HFR is suitable for fuel, materials and components testing for different reactor types. Irradiation experiments carried out at the HFR are mainly focused on the understanding of the irradiation effects on materials; and providing databases for irradiation behavior of materials to feed into safety cases. The irradiation experiments and materials testing at the HFR include the following issues. First, materials irradiation to support the nuclear plant life extensions, for instance, characterization of the reactor pressure vessel stainless steel claddings to insure structural integrity of the vessel, as well as irradiation of the weld material coupons to neutron fluence levels that are representative for Light Water Reactors (LWR) internals applications. Secondly, development and qualification of the structural materials for next generation nuclear fission reactors as well as thermo-nuclear fusion machines. The main areas of interest are in both conventional stainless steel and advanced reduced activation steels and special alloys such as Ni-base alloys. For instance safety-relevant aspects of High Temperature Reactors (HTR) such as the integrity of fuel and structural materials with increasing neutron fluence at typical HTR operating conditions has been recently assessed. Thirdly, support of the fuel safety through several fuel irradiation experiments including testing of pre-irradiated LWR fuel rods containing UO 2 or MOX fuel. Fourthly

  20. NRX and NRU reactor research facilities and irradiation and examination charges

    International Nuclear Information System (INIS)

    1960-08-01

    This report details the irradiation and examination charges on the NRX and NRU reactors at the Chalk River Nuclear Labs. It describes the NRX and NRU research facilities available to external users. It describes the various experimental holes and loops available for research. It also outlines the method used to calculate the facilities charges and the procedure for applying to use the facilities as well as the billing procedures.

  1. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    Farrar, L.C.; Allison, C.M.; Croucher, D.W.; Ploger, S.A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m 2 . After a flow reduction to 2120 kg/s-m 2 , film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  2. Status and possible prospects of an international fusion materials irradiation facility

    International Nuclear Information System (INIS)

    Cozzani, F.

    1999-01-01

    Structural materials for future DT fusion power reactors will have to operate under intense neutron fields with energies up to 14 MeV and fluences in the order of 2 MW/m 2 per year. As environmental acceptability, safety considerations and economic viability will be ultimately the keys to the widespread introduction of fusion power, the development of radiation-resistant and low activation materials would contribute significantly to fusion development. For this purpose, testing of materials under irradiation conditions close to those expected in a fusion power station would require the availability, in an appropriate time framework, of an intense, high-energy neutron source. Recent advances in linear accelerator technology, in small specimens testing technology, and in the comprehension of damage phenomena, lead to the conclusion that an accelerator-based D-Li neutron source, with beam energy variability, would provide the most realistic option for a fusion materials testing facility. Under the auspices of the IEA, an international effort (EU, Japan, US, RF) to carry out the conceptual design activities (CDA) of an international fusion materials irradiation facility (IFMIF), based on the D-Li concept, have been carried out successfully. A final conceptual design report was produced at the end of 1996. A phase of conceptual design evaluation (CDE), presently underway, is extending and further refining some of the conceptual design details of IFMIF. The results indicate that an IFMIF-class installation would be technically feasible and could meet its mission objectives. However, a suitable phase of Engineering Validation, to carry out some complementary R and D and prototyping, would still be needed to resolve a few key technical uncertainties before the possibility to proceed toward detailed design and construction could be explored. (orig.)

  3. Early works on the nuclear microprobe for microelectronics irradiation tests at the CEICI (Sevilla, Spain)

    International Nuclear Information System (INIS)

    Palomo, F.R.; Morilla, Y.; Mogollon, J.M.; Garcia-Lopez, J.; Labrador, J.A.; Aguirre, M.A.

    2011-01-01

    Particle radiation effects are a fundamental problem in the use of numerous electronic devices for space applications, which is aggravated with the technology shrinking towards smaller and smaller scales. The suitability of low-energy accelerators for irradiation testing is being considered nowadays. Moreover, the possibility to use a nuclear microprobe, with a lateral resolution of a few microns, allows us to evaluate the behavior under ion irradiation of specific elements in an electronic device. The CEICI is the new CEnter for Integrated Circuits Irradiation tests, created into the facilities at the Centro Nacional de Aceleradores (CNA) in Sevilla-Spain. We have verified that our 3 MV Tandem accelerator, typically used for ion beam characterization of materials, is also a valuable tool to perform irradiation experiments in the low LET (Linear Energy Transfer) region.

  4. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    Directory of Open Access Journals (Sweden)

    Hu J.-P.

    2016-01-01

    Full Text Available Radiation dosimetry for Neutron Capture Therapy (NCT has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR. In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1 in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2 out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3 beam shutter upgrade to reduce strayed neutrons and gamma dose, (4 beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5 beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates to reduce prompt gamma and fast neutron doses, (6 sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7 holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4–7

  5. Dosimetry in Thermal Neutron Irradiation Facility at BMRR

    Energy Technology Data Exchange (ETDEWEB)

    Hu, J. P. [Brookhaven National Lab. (BNL), Upton, NY (United States); Holden, N. E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Reciniello, R. N.

    2014-05-23

    Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D2O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4 - 7

  6. IFMIF-KEP. International fusion materials irradiation facility key element technology phase report

    International Nuclear Information System (INIS)

    2003-03-01

    The International Fusion Materials Irradiation Facility (IFMIF) is an accelerator-based D-Li neutron source designed to produce an intense neutron field that will simulate the neutron environment of a D-T fusion reactor. IFMIF will provide a neutron flux equivalent to 2 MW/m 2 , 20 dpa/y in Fe, in a volume of 500 cm 3 and will be used in the development and qualification of materials for fusion systems. The design activities of IFMIF are performed under an IEA collaboration which began in 1995. In 2000, a three-year Key Element Technology Phase (KEP) of IFMIF was undertaken to reduce the key technology risk factors. This KEP report describes the results of the three-year KEP activities in the major project areas of accelerator, target, test facilities and design integration. (author)

  7. Thermohydraulic study of a MTR fuel element aimed at the construction of an irradiation facility

    International Nuclear Information System (INIS)

    Coragem, Helio Boemer de Oliveira

    1980-01-01

    A thermohydraulic study of MTR fuel element is presented as a basic requirement for the development of an irradiation facility for testing fuel elements. A computer code named 'Thermo' has been developed for this purpose, which can stimulate different working conditions, such as, cooling, power elements and neutron flux, performing all pertinent thermohydraulic calculations. Thermocouples were used to measure the temperature gradients of the cooling fluid throughout the IEAR-1 reactor core. All experimental data are in good agreement with the theoretical model applied in this work. Finally, a draft of the proposed facility and its safety system is presented. (author)

  8. GIF++: A new CERN Irradiation Facility to test large-area particle detectors for the High-Luminosity LHC program

    CERN Document Server

    Guida, Roberto

    2016-01-01

    The high-luminosity LHC (HL-LHC) upgrade is setting a new challenge for particle detector technologies. The increase in luminosity will produce a higher particle background with respect to present conditions. To study performance and stability of detectors at LHC and future HL-LHC upgrades, a new dedicated facility has been built at CERN: the new Gamma Irradiation Facility (GIF++). The GIF++ is a unique place where high energy charged particle beams (mainly muons) are combined with gammas from a 14 TBq 137Cesium source which simulates the background radiation expected at the LHC experiments. Several centralized services and infrastructures are made available to the LHC detector community to facilitate the different R&D; programs.

  9. Updated FY12 Ceramic Fuels Irradiation Test Plan

    International Nuclear Information System (INIS)

    Nelson, Andrew T.

    2012-01-01

    The Fuel Cycle Research and Development program is currently devoting resources to study of numerous fuel types with the aim of furthering understanding applicable to a range of reactors and fuel cycles. In FY11, effort within the ceramic fuels campaign focused on planning and preparation for a series of rabbit irradiations to be conducted at the High Flux Isotope Reactor located at Oak Ridge National Laboratory. The emphasis of these planned tests was to study the evolution of thermal conductivity in uranium dioxide and derivative compositions as a function of damage induced by neutron damage. Current fiscal realities have resulted in a scenario where completion of the planned rabbit irradiations is unlikely. Possibilities for execution of irradiation testing within the ceramic fuels campaign in the next several years will thus likely be restricted to avenues where strong synergies exist both within and outside the Fuel Cycle Research and Development program. Opportunities to augment the interests and needs of modeling, advanced characterization, and other campaigns present the most likely avenues for further work. These possibilities will be pursued with the hope of securing future funding. Utilization of synthetic microstructures prepared to better understand the most relevant actors encountered during irradiation of ceramic fuels thus represents the ceramic fuel campaign's most efficient means to enhance understanding of fuel response to burnup. This approach offers many of the favorable attributes embraced by the Separate Effects Testing paradigm, namely production of samples suitable to study specific, isolated phenomena. The recent success of xenon-imbedded thick films is representative of this approach. In the coming years, this strategy will be expanded to address a wider range of problems in conjunction with use of national user facilities novel characterization techniques to best utilize programmatic resources to support a science-based research program.

  10. Final safety analysis report for the irradiated fuels storage facility

    International Nuclear Information System (INIS)

    Bingham, G.E.; Evans, T.K.

    1976-01-01

    A fuel storage facility has been constructed at the Idaho Chemical Processing Plant to provide safe storage for spent fuel from two commercial HTGR's, Fort St. Vrain and Peach Bottom, and from the Rover nuclear rocket program. The new facility was built as an addition to the existing fuel storage basin building to make maximum use of existing facilities and equipment. The completed facility provides dry storage for one core of Peach Bottom fuel (804 elements), 1 1 / 2 cores of Fort St. Vrain fuel (2200 elements), and the irradiated fuel from the 20 reactors in the Rover program. The facility is designed to permit future expansion at a minimum cost should additional storage space for graphite-type fuels be required. A thorough study of the potential hazards associated with the Irradiated Fuels Storage Facility has been completed, indicating that the facility is capable of withstanding all credible combinations of internal accidents and pertinent natural forces, including design basis natural phenomena of a 10,000 year flood, a 175-mph tornado, or an earthquake having a bedrock acceleration of 0.33 g and an amplification factor of 1.3, without a loss of integrity or a significant release of radioactive materials. The design basis accident (DBA) postulated for the facility is a complete loss of cooling air, even though the occurrence of this situation is extremely remote, considering the availability of backup and spare fans and emergency power. The occurrence of the DBA presents neither a radiation nor an activity release hazard. A loss of coolant has no effect upon the fuel or the facility other than resulting in a gradual and constant temperature increase of the stored fuel. The temperature increase is gradual enough that ample time (28 hours minimum) is available for corrective action before an arbitrarily imposed maximum fuel centerline temperature of 1100 0 F is reached

  11. An industrial 60Co gamma irradiation facility in China

    International Nuclear Information System (INIS)

    Jin Yongling; Zhou Ruiying; Wang Binglin

    1990-01-01

    The radiation processing has developed very fast in China since 1980. There are more than 100 of 60 Co radiation facilities having been set up. Majority of them was with relatively small capacity and was used mainly for the laboratory study. An industrial radiation facility has been established and put into operation in Beijing Radiation Application Center (BRAC) recently. The project was based on the research works of irradiation technology during the period of 1980-1985. The main pre-research work was radiation sterilization of medical products and food irradiation. This work has obtained an award from State Commission of Science and Technology. The Commission has arranged the construction of an industrial sterilization plant for medical products as a major import project. The project has also been supported by IAEA as project CPR/8/002. The project includes a plant of production of 100,000,000 needles per year, a plant of production of 50,000,000 syringes per year and an automatic irradiation plant. All three parts have been set up now. The maximum capacity of 60 Co sources is 3.7 x 10 16 Bq, the first-time-loaded source is 12.21 x 10 15 Bq. (author)

  12. Irradiation facilities for materials research: IFMIF and small scale installations

    International Nuclear Information System (INIS)

    Perlado, J. M.; Victoria, M.

    2007-01-01

    The research of advance materials in nuclear fields such as new fission reactors (Generation-IV), Accelerator Driven Systems for Transmutation of Radioactive Wastes and Nuclear Fusion, is becoming very much common in the types of low activation and radiation resistant Materials. Ferritic-Martensitic Steels (based in 9-12 Cr) with or without Oxide Dispersion Techniques (Ytria Nanoparticles), Composites materials are becoming the new generation to answer requirements of high temperature, high radiation resistance of structural materials. Special dedication is appearing in general research programmes to this area of Materials. The understanding of their final performance needs a wider knowledge of the mechanisms of radiation damage in these materials from the atomistic scale to the macroscopic responses. New extensive campaigns are being funded to irradiate from simple elements to model alloys and finally the complex materials themselves. That sequence and its state of art will be presented One clear technique for that understanding is the Multi scale Modelling which includes simulation techniques from quantum mechanics, molecular dynamics, defects diffusion, mesoscopic modelling and finally the macroscopic constitutive relations for macroscopic analysis. However, in each one of these steps is necessary a systematic and well established program of experiments that combines the irradiation and the very detailed analysis with techniques such as Transmission Electron Microscope, Positron Annihilation, SIMS, Atom Probe, Nanoindebntation. A key aspect that wants to be presented in this work is the state of art and discussion of Irradiation Facilities for Materials studies. Those facilities goes from ion implantation sources, small accelerator, Experimental Reactors such High Flux Reactor, sophisticated Triple Beams Sources as JANNUS in France to generate at the same time displacements-hydrogen-helium, and projected very large neutron installation such as IFMIF. The role to

  13. Characterization of the fast neutron irradiation facility of the Portuguese Research Reactor after core conversion

    International Nuclear Information System (INIS)

    Marques, J.G.; Sousa, M.; Santos, J.P.; Fernandes, A.C.

    2011-01-01

    The fast neutron irradiation facility of the Portuguese Research Reactor was characterized after the reduction in uranium enrichment and rearrangement of the core configuration. In this work we report on the determination of the hardness parameter and the 1 MeV equivalent neutron flux along the facility, in the new irradiation conditions, following ASTM E722 standard.

  14. Status of fuel irradiation tests in HANARO

    International Nuclear Information System (INIS)

    Kim, Hark Rho; Lee, Choong Sung; Lee, Kye Hong; Jun, Byung Jin; Lee, Ji Bok

    1999-01-01

    Since 1996 after finishing the long-term operational test, HANARO (High-Flux Advanced Neutron Application Reactor) has been extensively used for material irradiation tests, beam application research, radioisotope production and neutron activation analysis. This paper presents the fuel irradiation test activities which are now conducted or have been finished in HANARO. KAERI developed LEU fuel using an atomization method for the research reactors. Using this LEU, we have set up and conducted three irradiation programs: (1) medium power irradiation test using a short-length mini-assembly made of 3.15 gU/cc U 3 Si, (2) high power irradiation tests using full-length test assemblies made of 3.15 gU/cc U 3 Si, and (3) irradiation test using a short-length mini-plate made of 4.8 gU/cc U 3 Si 2 . DUPIC (Direct Use of spent PWR fuels in CANDU Reactors) simulation fuel pellets, of which compositions are very similar to DUPIC pellets to keep the similarity in the thermo-mechanical property, were developed. Three mini-elements including 5 pellets each were installed in a capsule. This capsule has been irradiated for 2 months and unloaded from the HANARO core at the end of September 1999. Another very important test is the HANARO fuel qualification program at high power, which is required to resolve the licensing issue. This test is imposed on the HANARO operation license due to insufficient test data under high power environment. To resolve this licensing issue, we have been carrying out the required irradiation tests and PIE (Post-irradiation Examination) tests. Through this program, it is believed that the resolution of the licensing issue is achieved. In addition to these programs, several fuel test plans are under way. Through these vigorous activities of fuel irradiation test programs, HANARO is sure to significantly contribute to the national nuclear R and D programs. (author)

  15. Nuclear data for the production of radioisotopes in fusion materials irradiation facility

    International Nuclear Information System (INIS)

    Cheng, E.T.; Schenter, R.E.; Mann, F.M.; Ikeda, Y.

    1991-01-01

    The fusion materials irradiation facility (FMIF) is a neutron source generator that will produce a high-intensity 14-MeV neutron field for testing candidate fusion materials under reactor irradiation conditions. The construction of such a facility is one of the very important development stages toward realization of fusion energy as a practical energy source for electricity production. As a result of the high-intensity neutron field, 10 MW/m 2 or more equivalent neutron wall loading, and the relatively high-energy (10- to 20-MeV) neutrons, the FMIF, as future fusion reactors, also bears the potential capability of producing a significant quantity of radioisotopes. A study is being conducted to identify the potential capability of the FMIF to produce radioisotopes for medical and industrial applications. Two types of radioisotopes are involved: one is already available; the second might not be readily available using conventional production methods. For those radioisotopes that are not readily available, the FMIF could develop significant benefits for future generations as a result of the availability of such radioisotopes for medical or industrial applications. The current production of radioisotopes could help finance the operation of the FMIF for irradiating the candidate fusion materials; thus this concept is attractive. In any case, nuclear data are needed for calculating the neutron flux and spectrum in the FMIF and the potential production rates of these isotopes. In this paper, the authors report the result of a preliminary investigation on the production of 99 Mo, the parent radioisotope for 99m Tc

  16. Irradiated test fuel shipment plan for the LWR MOX fuel irradiation test project

    International Nuclear Information System (INIS)

    Shappert, L.B.; Dickerson, L.S.; Ludwig, S.B.

    1998-01-01

    This document outlines the responsibilities of DOE, DOE contractors, the commercial carrier, and other organizations participating in a shipping campaign of irradiated test specimen capsules containing mixed-oxide (MOX) fuel from the Idaho National Engineering and Environmental Laboratory (INEEL) to the Oak Ridge National Laboratory (ORNL). The shipments described here will be conducted according to applicable regulations of the US Department of Transportation (DOT), US Nuclear Regulatory Commission (NRC), and all applicable DOE Orders. This Irradiated Test Fuel Shipment Plan for the LWR MOX Fuel Irradiation Test Project addresses the shipments of a small number of irradiated test specimen capsules and has been reviewed and agreed to by INEEL and ORNL (as participants in the shipment campaign). Minor refinements to data entries in this plan, such as actual shipment dates, exact quantities and characteristics of materials to be shipped, and final approved shipment routing, will be communicated between the shipper, receiver, and carrier, as needed, using faxes, e-mail, official shipping papers, or other backup documents (e.g., shipment safety evaluations). Any major changes in responsibilities or data beyond refinements of dates and quantities of material will be prepared as additional revisions to this document and will undergo a full review and approval cycle

  17. LWR fuel rod testing facilities in high flux reactor (HFT) Petten for investigation of power cycling and ramping behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Markgraf, J; Perry, D; Oudaert, J [Commission of the European Communities, Joint Reserach Centre, Petten Establishment, Petten (Netherlands)

    1983-06-01

    LWR fuel rod irradiation experiments are being performed in HFR's Pool Side Facility (PSF) by means of pressurized boiling water capsules (BWFC). For more than 6 years the major application of these devices has been in performing irradiation programs to investigate the power ramp behaviour of PWR and BWR rods which have been pre-irradiated in power reactors. Irradiation devices with various types of monitoring instrumentation are available, e.g. for fuel rod length, fuel stack length, fuel rod internal pressure and fuel rod central temperature measurements. The application scope covers PWR and BWR fuel rods, with burn-up levels up to 45 MWd/kg(U), max. linear heat generation rates up to 700 W/cm and simulation of constant power change rates between 0.05 and 1000 W/cm.min. The paper describes the different designs of LWR fuel rod testing facilities and associated non-destructive testing devices in use at the HFR Petten. It also addresses the new test capabilities that will become available after exchange of the HFR vessel in 1983. Furthermore it shows some typical results. (author)

  18. Tensile tests and metallography of brazed AISI 316L specimens after irradiation

    International Nuclear Information System (INIS)

    Groot, P.; Franconi, E.

    1994-01-01

    Stainless steel type 316L tensile specimens were vacuum brazed with three kinds of alloys: BNi-5, BNi-6, and BNi-7. The specimens were irradiated up to 0.7 dpa at 353 K in the High Flux Reactor at JRC Petten, the Netherlands. Tensile tests were performed at a constant displacement rate of 10 -3 s -1 at room temperature in the ECN hot cell facility. BNi-5 brazed specimens showed ductile behaviour. Necking and fractures were localized in the plate material. BNi-6 and BNi-7 brazed specimens failed brittle in the brazed zone. This was preceded by uniform deformation of the plate material. Tensile test results of irradiated specimens showed higher stresses due to radiation hardening and a reduction of the elongation of the plate material compared to the reference. SEM examination of the irradiated BNi-6 and BNi-7 fracture surfaces showed nonmetallic phases. These phases were not found in the reference specimens. ((orig.))

  19. Interim dry cask storage of irradiated Fast Flux Test Facility fuel

    International Nuclear Information System (INIS)

    Scott, P.L.

    1994-09-01

    The Fast Flux Test Facility (FFTF), located at the US Department of Energy's (DOE'S) Hanford Site, is the largest, most modern, liquid metal-cooled test reactor in the world. This paper will give an overview of the FFTF Spent Fuel Off load project. Major discussion areas will address the status of the fuel off load project, including an overview of the fuel off load system and detailed discussion on the individual components that make up the dry cask storage portion of this system. These components consist of the Interim Storage Cask (ISC) and Core Component Container (CCC). This paper will also discuss the challenges that have been addressed in the evolution of this project

  20. A 14 MeV neutron irradiation facility with an automated fast cyclic pneumatic

    International Nuclear Information System (INIS)

    Montgomery, M.T.; Yoho, M.D.; Biegalski, S.R.; Landsberger, S.; Welch, L.

    2016-01-01

    This work details the design criteria, construction, controls, and optimization of the 14 MeV neutron irradiation facility at the University of Texas, built with the motivation of performing neutron activation analysis on samples with short half-lives. The facility couples a D-T neutron generator with a pneumatic transfer system capable of transit of approximately one second between source and detector, while the cyclic automated nature allows for many irradiation/count trials with any number of samples, translating to significantly improved counting statistics. (author)

  1. Dose mapping of the multi-purpose gamma irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Cabalfin, E G; Lanuza, L G; Villamater, D T [Irradiation Services, Nuclear Services and Training Division, Philippine Nuclear Research Institute, Quezon City (Philippines)

    1989-12-01

    In radiation processing, reliable dosimetry constitutes a very important part of process control and quality assurance. Radiation dosimetry is the only acceptable method to guarantee that the irradiated product has undergone the correct radiation treatment. In preparation therefore, for the routine operation of the newly installed multi-purpose gamma irradiation facility at the Philippine Nuclear Research Institute (PNRI), dose mapping distribution studies were undertaken. Results of dose distribution in air as well as in dummy product are presented. The effects of product bulk density, product geometry and product to source distance on minimum absorbed dose and uniformity ratio have been determined. (Author).

  2. Dose mapping of the multi-purpose gamma irradiation facility

    International Nuclear Information System (INIS)

    Cabalfin, E.G.; Lanuza, L.G.; Villamater, D.T.

    1989-01-01

    In radiation processing, reliable dosimetry constitutes a very important part of process control and quality assurance. Radiation dosimetry is the only acceptable method to guarantee that the irradiated product has undergone the correct radiation treatment. In preparation therefore, for the routine operation of the newly installed multi-purpose gamma irradiation facility at the Philippine Nuclear Research Institute (PNRI), dose mapping distribution studies were undertaken. Results of dose distribution in air as well as in dummy product are presented. The effects of product bulk density, product geometry and product to source distance on minimum absorbed dose and uniformity ratio have been determined. (Author)

  3. An automatic device for sample insertion and extraction to/from reactor irradiation facilities

    International Nuclear Information System (INIS)

    Alloni, L.; Venturelli, A.; Meloni, S.

    1990-01-01

    At the previous European Triga Users Conference in Vienna,a paper was given describing a new handling tool for irradiated samples at the L.E.N.A plant. This tool was the first part of an automatic device for the management of samples to be irradiated in the TRIGA MARK ii reactor and successively extracted and stored. So far sample insertion and extraction to/from irradiation facilities available on reactor top (central thimble,rotatory specimen rack and channel f),has been carried out manually by reactor and health-physics operators using the ''traditional'' fishing pole provided by General Atomic, thus exposing reactor personnel to ''unjustified'' radiation doses. The present paper describes the design and the operation of a new device, a ''robot''type machine,which, remotely operated, takes care of sample insertion into the different irradiation facilities,sample extraction after irradiation and connection to the storage pits already described. The extraction of irradiated sample does not require the presence of reactor personnel on the reactor top and,therefore,radiation doses are strongly reduced. All work from design to construction has been carried out by the personnel of the electronic group of the L.E.N.A plant. (orig.)

  4. Food irradiation in China

    International Nuclear Information System (INIS)

    Zhu Jiang

    1994-01-01

    In this paper, the author discussed the recent situation of food irradiation in China, its history, facilities, clearance, commercialization, and with emphasis on market testing and public acceptance of irradiated food. (author)

  5. A study of the multigap RPC at the gamma irradiation facility at CERN

    International Nuclear Information System (INIS)

    Akindinov, A.; Alici, A.; Anselmo, F.; Antonioli, P.; Baek, Y.; Basile, M.; Romeo, G.C.G. Cara; Cerron-Zeballos, E.; Cifarelli, L.; Cindolo, F.; Caro, A. De; Pasquale, S. De; Bartolomeo, A. Di; Girard, M.F.M. Fusco; Guida, M.; Hatzifotiadou, D.; Kisselev, S.M.; Laurenti, G.; Luvisetto, M.L.; Margotti, A.; Martemiyanov, A.N.; Morozov, S.; Nania, R.; Pesci, A.; Pierella, F.; Scioli, G.; Sellitto, S.; Smirnitski, A.V.; Valenti, G.; Vicinanza, D.; Williams, M.C.S.; Witoszynskyj, S.; Zagreev, B.V.; Zichichi, A.

    2002-01-01

    The selected device for the ALICE Time-of-Flight array is the Multigap Resistive Plate Chamber (MRPC). We have tested this device at the Gamma Irradiation Facility at CERN to evaluate the rate dependence. We find that the rate capability of the MRPC easily exceeds the 50 Hz/cm 2 maximum expected rate at the ALICE experiment. In addition, we have measured the power dissipated for an equivalent flux of 1.6 kHz/cm 2 of through-going muons to be 650 mW/m 2

  6. IFMIF-KEP. International fusion materials irradiation facility key element technology phase report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    The International Fusion Materials Irradiation Facility (IFMIF) is an accelerator-based D-Li neutron source designed to produce an intense neutron field that will simulate the neutron environment of a D-T fusion reactor. IFMIF will provide a neutron flux equivalent to 2 MW/m{sup 2}, 20 dpa/y in Fe, in a volume of 500 cm{sup 3} and will be used in the development and qualification of materials for fusion systems. The design activities of IFMIF are performed under an IEA collaboration which began in 1995. In 2000, a three-year Key Element Technology Phase (KEP) of IFMIF was undertaken to reduce the key technology risk factors. This KEP report describes the results of the three-year KEP activities in the major project areas of accelerator, target, test facilities and design integration. (author)

  7. Comparison of proton microbeam and gamma irradiation for the radiation hardness testing of silicon PIN diodes

    Science.gov (United States)

    Jakšić, M.; Grilj, V.; Skukan, N.; Majer, M.; Jung, H. K.; Kim, J. Y.; Lee, N. H.

    2013-09-01

    Simple and cost-effective solutions using Si PIN diodes as detectors are presently utilized in various radiation-related applications in which excessive exposure to radiation degrades their charge transport properties. One of the conventional methods for the radiation hardness testing of such devices is time-consuming irradiation with electron beam or gamma-ray irradiation facilities, high-energy proton accelerators, or with neutrons from research reactors. Recently, for the purpose of radiation hardness testing, a much faster nuclear microprobe based approach utilizing proton irradiation has been developed. To compare the two different irradiation techniques, silicon PIN diodes have been irradiated with a Co-60 gamma radiation source and with a 6 MeV proton microbeam. The signal degradation in the silicon PIN diodes for both irradiation conditions has been probed by the IBIC (ion beam induced charge) technique, which can precisely monitor changes in charge collection efficiency. The results presented are reviewed on the basis of displacement damage calculations and NIEL (non-ionizing energy loss) concept.

  8. Storage tests with irradiated and non-irradiated onions

    International Nuclear Information System (INIS)

    Gruenewald, T.; Rumpf, G.; Troemel, I.; Bundesforschungsanstalt fuer Ernaehrung, Karlsruhe

    1978-07-01

    The results of several test series on the storage of irradiated and non-irradiated German grown onion are reported. Investigated was the influence of the irradiation conditions such as time and dose and of the storage conditions on sprouting, spoilage, browning of the vegetation centres, composition of the onions, strength and sensorial properties of seven different onion varieties. If the onions were irradiated during the dormancy period following harvest, a dose of 50 Gy (krad) was sufficient to prevent sprouting. Regarding the irradiated onions, it was not possible by variation of the storage conditions within the limits set by practical requirements to extend the dormancy period or to prevent browning of the vegetation centres, however. (orig.) 891 MG 892 RSW [de

  9. An irradiation facility with a horizontal beam for radiobiological studies

    International Nuclear Information System (INIS)

    Czub, J.; Adamus, T.; Banas, D.

    2006-01-01

    A facility with a horizontal beam for radiobiological experiments with heavy ions has been designed and constructed at the Heavy Ion Laboratory in Warsaw University. The facility is optimal to investigate the radiobiological effects of charged heavy particles on a cellular or molecular level as the plateau of the Bragg curve as well as in the Bragg peak. The passive beam spread out by a thin scattering foil provides a homogeneous irradiation field over an area of at least 1 x 1 cm 2 . For in vitro irradiation of biological samples the passive beam spreading combined with the x - y mechanical scanning of the irradiated sample was found to be an optimum solution. Using x - y step motor, the homogenous beam of ions with the energy loss range in the cells varied from 1 MeV/μm to 200 keV/μm is able to cover a 6 cm in diameter Petri dish that holds the biological samples. Moreover on-line fluence monitoring based on single-particle counting is performed to determine the dose absorbed by cells. Data acquisition system for dosimetry and ion monitoring based on a personal computer is described. (author)

  10. Irradiation Effects Test Series: Test IE-3. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, L. C.; Allison, C. M.; Croucher, D. W.; Ploger, S. A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m/sup 2/. After a flow reduction to 2120 kg/s-m/sup 2/, film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions.

  11. X-ray microbeam stand-alone facility for cultured cells irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bożek, Sebastian, E-mail: sebastian.bozek@yahoo.com [Jagiellonian University Medical College, Department of Pharmaceutical Biophysics, Krakow (Poland); Bielecki, Jakub; Wiecheć, Anna; Lekki, Janusz; Stachura, Zbigniew; Pogoda, Katarzyna; Lipiec, Ewelina; Tkocz, Konrad; Kwiatek, Wojciech M. [Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow (Poland)

    2017-03-01

    Highlights: • An X-ray microbeam line for irradiation of living cultured cells was constructed. • A step by step explanation of working principles with engineering details, procedures and calculations is presented. • A model of beam and cell interaction is presented. • A method of uniform irradiation of living cells with an exact dose per a cell is presented. • Results of preliminary experiments are presented. - Abstract: The article describes an X-ray microbeam standalone facility dedicated for irradiation of living cultured cells. The article can serve as an advice for such facilities construction, as it begins from engineering details, through mathematical modeling and experimental procedures, ending up with preliminary experimental results and conclusions. The presented system consists of an open type X-ray tube with microfocusing down to about 2 μm, an X-ray focusing system with optical elements arranged in the nested Kirckpatrick-Baez (or Montel) geometry, a sample stand and an optical microscope with a scientific digital CCD camera. For the beam visualisation an X-ray sensitive CCD camera and a spectral detector are used, as well as a scintillator screen combined with the microscope. A method of precise one by one irradiation of previously chosen cells is presented, as well as a fast method of uniform irradiation of a chosen sample area. Mathematical models of beam and cell with calculations of kerma and dose are presented. The experiments on dose-effect relationship, kinetics of DNA double strand breaks repair, as well as micronuclei observation were performed on PC-3 (Prostate Cancer) cultured cells. The cells were seeded and irradiated on Mylar foil, which covered a hole drilled in the Petri dish. DNA lesions were visualised with γ-H2AX marker combined with Alexa Fluor 488 fluorescent dye.

  12. Conceptual design of a conveyor system for the Philippine multipurpose cobalt-60 gamma irradiation facility

    International Nuclear Information System (INIS)

    Borras, A.M.

    1992-01-01

    The Multipurpose Cobalt-60 Gamma Irradiation Facility at the PNRI presently utilizes the batch irradiation method using turntables to rotate the product boxes. The target materials or products are being carried manually or with the use of pushcart through the personnel maze. This paper presents a conceptual design for the best suitable product-handling or conveyor system for the Philippine Multipurpose Cobalt-60 Gamma Irradiation Facility. The main irradiation conveyor line shall be a 55 cm x 200 cm slat-type conveyor made of SUS 304 material that could be operated in a semi-batch continuous flow and/or shuffle-dwell method with a tact-time range of 10 min to 7 h. The products can be irradiated in a single direction, two-pass, two-sided method. (auth.). 11 refs.; 4 figs.; 2 tabs

  13. Irradiation test on connector part for nuclear instrumentation of nuclear powered ship 'Mutsu'

    International Nuclear Information System (INIS)

    Kudo, Takahiro; Mizushima, Toshihiko; Tsunoda, Tsunemi; Nakazawa, Toshio

    1991-01-01

    The nuclear instrumetnation facility of the nuclear powered ship 'Mutsu' is composed of neutron detectors, signal cables and the circuits for measurement, and ocntinuously monitors neutron flux. Since this facility treats very faint signals, for the signal cables, coaxial cables and triple coaxial cables are used. The coaxial cables for the nuclear instrumentation are equipped with connectors at both ends, and those are called prefabricated cable. The prefabricated cables are connected to neutron detectors, and installed in the detection holes of the primary shielding tank in the containment vessel. Therefore, at the time of reactor operation, they are exposed to high radiation, and the deterioration of the characteristics of the prefabricated cables is feared. For the purpose of confirming that the part of deteriorating the insulation of the prefabricated cables is connectors, and clarifying the cause of the deterioration of insulation in connector part, the irradiation test of this time was carried out. The environment in which the prefabricated cables are laid, the specifications of the cables and connectors, the materials, gamma ray irradiation and the test results are reported. (K.I.)

  14. Design and manufacturing of instrumented capsule (02F-06K/02F-11K) for nuclear fuel irradiation test in HANARO

    International Nuclear Information System (INIS)

    Kim, Bong Goo; Kang, Y. H.; Cho, M. S.; Sohn, J. M.; Choo, K. N.; Kim, D. S.; Oh, J. M.; Shin, Y.T.; Park, S.J.; Kim, Y. J.; Seo, C.G.; Ryu, J.S.; Cho, Y. G.

    2003-02-01

    To measure the characteristics of nuclear fuel during irradiation test, it is necessary to develop the instrumented capsule for the nuclear fuel irradiation test. Then considering the requirements for the nuclear fuel irradiation test and the compatibility with OR test hole in HANARO as well as the requirements for HANARO operation and related equipments, the instrumented capsule for the nuclear fuel irradiation test was designed and successfully manufactured. The structural integrity of the capsule design was verified by performing nuclear physics, structural and thermal analyses. And, not only out-of-pile tests such as pressure drop test, vibration test, endurance test, were performed in HANARO design verification test facility, but the mechanical and hydraulic safety of the capsule and the compatibility of the capsule with HANARO was verified

  15. Postirradiation examination results for the Irradiation Effects Test Series IE-ST-2, Rod IE-002

    International Nuclear Information System (INIS)

    Murdock, B.A.

    1977-12-01

    A postirradiation examination was conducted on a zircaloy-clad, UO 2 -fueled, pressurized water reactor (PWR) type rod which had been tested in the Power Burst Facility as part of the Irradiation Effects Test Series of the Thermal Fuels Behavior Program. The fuel rod, previously irradiated to a burnup of 15,800 MWd/t was subjected to a power ramp from 28 to 55 kW/m peak power at an average ramp rate of 4 kW/m/min. Posttest fuel restructuring and relocation, fission product redistribution, and fuel rod cladding deformation were evaluated and analyzed

  16. Irradiation enhanced diffusion and irradiation creep tests in stainless steel alloys

    International Nuclear Information System (INIS)

    Loelgen, R.H.; Cundy, M.R.; Schuele, W.

    1977-01-01

    A review is given of investigations on the rate of phase changes during neutron and electron irradiation in many different fcc alloys showing either precipitation or ordering. The diffusion rate was determined as a function of the irradiation flux, the irradiation temperature and the irradiation dose. It was found that the radiation enhanced diffusion in all the investigated alloys is nearly temperature independent and linearly dependent on the flux. From these results conclusions were drawn concerning the properties of point defects and diffusion mechanisms rate determining during irradiation, which appears to be of a common nature for fcc alloys having a similar structure to those investigated. It has been recognized that the same dependencies which are found for the diffusion rate were also observed for the irradiation creep rate in stainless steels, as reported in literature. On the basis of this observation a combination of measurements is suggested, of radiation enhanced diffusion and radiation enhanced creep in stainless steel alloys. The diffusion tests will be performed at the Euratom Joint Research Centre in Ispra, Italy, and the irradiation creep tests will be carried out in the High Flux Reactor /9/ of the Euratom Joint Research Centre in Petten, The Netherlands. In order to investigate irradiation creep on many samples at a time two special rigs were developed which are distinguished only by the mode of stress applied to the steel specimens. In the first type of rig about 50 samples can be tested uniaxially under tension with various combinations of irradiation temperature and stress. The second type of rig holds up to 70 samples which are tested in bending, again with various combinations of irradiation temperature and stress

  17. Neutron Flux Characterization of Irradiation Holes for Irradiation Test at HANARO

    Directory of Open Access Journals (Sweden)

    Yang Seong Woo

    2016-01-01

    Full Text Available The High flux Advanced Neutron Application ReactOr (HANARO is a unique research reactor in the Republic of Korea, and has been used for irradiation testing since 1998. To conduct irradiation tests for nuclear materials, the irradiation holes of CT and OR5 have been used due to a high fast-neutron flux. Because the neutron flux must be accurately calculated to evaluate the neutron fluence of irradiated material, it was conducted using MCNP. The neutron flux was measured using fluence monitor wires to verify the calculated result. Some evaluations have been conducted, however, more than 20% errors have frequently occurred at the OR irradiation hole, while a good agreement between the calculated and measured data was shown at the CT irradiation hole.

  18. Shadow corrosion testing in the INCA facility in the Studsvik R2 reactor

    International Nuclear Information System (INIS)

    Nystrand, A.C.; Lassing, A.

    1999-01-01

    Shadow corrosion is a phenomenon which occurs when zirconium alloys are in contact with or in proximity to other metallic objects in a boiling water reactor environment (BWR, RBMK, SGHWR etc.). An enhanced corrosion occurs on the zirconium alloy with the appearance of a 'shadow' of the metallic object. The magnitude of the shadow corrosion can be significant, and is potentially limiting for the lifetime of certain zirconium alloy components in BWRs and other reactors with a similar water chemistry. In order to evaluate the suitability of the In-Core Autoclave (INCA) in the Studsvik R2 materials testing reactor as an experimental facility for studying shadow corrosion, a demonstration test has been performed. A number of test specimens consisting of Zircaloy-2 tubing in contact with Inconel were exposed in an oxidising water chemistry. Some of the specimens were placed within the reactor core and some above the core. The conclusion of this experiment after post irradiation examination is that it is possible to use the INCA facility in the Studsvik R2 reactor to develop a significant level of shadow corrosion after only 800 hours of irradiation. (author)

  19. Facilities projects performance measurement system

    International Nuclear Information System (INIS)

    Erben, J.F.

    1979-01-01

    The two DOE-owned facilities at Hanford, the Fuels and Materials Examination Facility (FMEF), and the Fusion Materials Irradiation Test Facility (FMIT), are described. The performance measurement systems used at these two facilities are next described

  20. Seismic analysis for shroud facility in-pile tube and saturated temperature capsules

    International Nuclear Information System (INIS)

    Iimura, Koichi; Yamaura, Takayuki; Ogawa, Mitsuhiro

    2009-07-01

    At Oarai Research and Development Center, Japan Atomic Energy Agency (JAEA), the plan of repairing and refurbishing Japan Materials Testing Reactor (JMTR) has progressed in order to restart JMTR operation in the fiscal 2011. As a part of effective use of JMTR, the neutron irradiation tests of LWR fuels and materials has been planned in order to study their soundness. By using Oarai Shroud Facility (OSF-1) and Fuel Irradiation Facility with the He-3 gas control system for power lamping test using Boiling Water Capsules (BOCA Irradiation Facility), the irradiation tests with power ramping will be carried out to study the soundness of fuel under LWR Transient condition. OSF-1 is the irradiation facility of shroud type that can insert and eject the capsule under reactor operation, and is composed of 'In-pile Tube', 'Cooling system' and 'Capsule exchange system'. BOCA Irradiation Facility is the facility which simulates irradiation environment of LWR, and is composed of 'Boiling water Capsule', 'Capsule control system' and 'Power control system by He-3'. By using Saturated temperature Capsules and the water environment control system, the material irradiation tests under the water chemistry condition of LWR will be carried out to clarify the mechanism of IASCC. In JMTR, these facilities are in service at the present. However, the detailed design for renewal or remodeling was carried out based on the new design condition in order to be correspondent to the irradiation test plan after restart JMTR operation. In this seismic analysis of the detailed design, each equipment classification and operating state were arranged with 'Japanese technical standards of the structure on nuclear facility for test research' and 'Technical guidelines for seismic design of nuclear power plants on current, and then, stress calculation and evaluation were carried out by FEM piping analysis code 'SAP' and structure analysis code 'ABAQUS'. About the stress of the seismic force, it was proven

  1. Irradiation test of fuel containing minor actinides in the experimental fast reactor Joyo

    International Nuclear Information System (INIS)

    Soga, Tomonori; Sekine, Takashi; Wootan, David; Tanaka, Kosuke; Kitamura, Ryoichi; Aoyama, Takafumi

    2007-01-01

    The mixed oxide containing minor actinides (MA-MOX) fuel irradiation program is being conducted using the experimental fast reactor Joyo of the Japan Atomic Energy Agency to research early thermal behavior of MA-MOX fuel. Two irradiation experiments were conducted in the Joyo MK-III 3rd operational cycle. Six prepared fuel pins included MOX fuel containing 3% or 5% americium (Am-MOX), MOX fuel containing 2% americium and 2% neptunium (Np/Am-MOX), and reference MOX fuel. The first test was conducted with high linear heat rates of approximately 430 W/cm maintained during only 10 minutes in order to confirm whether or not fuel melting occurred. After 10 minutes irradiation in May 2006, the test subassembly was transferred to the hot cell facility and an Am-MOX pin and a Np/Am-MOX pin were replaced with dummy pins including neutron dosimeters. The test subassembly loaded with the remaining four fuel pins was re-irradiated in Joyo for 24-hours in August 2006 at nearly the same linear power to obtain re-distribution data on MA-MOX fuel. Linear heat rates for each pin were calculated using MCNP, accounting for both prompt and delayed heating components, and then adjusted using E/C for 10 B (n, α) reaction rates measured in the MK-III core neutron field characterization test. Post irradiation examination of these pins to confirm the fuel melting and the local concentration under irradiation of NpO 2-x or AmO 2-x in the (U, Pu)O 2-x fuel are underway. The test results are expected to reduce uncertainties on the design margin in the thermal design for MA-MOX fuel. (author)

  2. A study of the multigap RPC at the $\\gamma$ irradiation facility at CERN

    CERN Document Server

    Akindinov, A; Anselmo, F; Antonioli, P; Baek, Y W; Basile, M; Cara Romeo, G; Cerron-Zeballos, E; Cifarelli, Luisa; Cindolo, F; Caro, A D; Pasquale, S D; Bartolomeo, A D; Fusco-Girard, M; Guida, M; Hatzifotiadou, D; Kisselev, S M; Laurenti, G; Luvisetto, M L; Margotti, A; Martemyanov, A N; Morozov, S; Nania, R; Pesci, A; Pierella, F; Scioli, G; Sellitto, S B; Smirnitsky, A V; Valenti, G; Vicinanza, D; Williams, M C S; Witoszynskyj, S; Zagreev, B V; Zichichi, A

    2002-01-01

    The selected device for the ALICE Time-of-Flight array is the Multigap Resistive Plate Chamber (MRPC). We have tested this device at the Gamma Irradiation Facility at CERN to evaluate the rate dependence. We find that the rate capability of the MRPC easily exceeds the 50 Hz/cm sup 2 maximum expected rate at the ALICE experiment. In addition, we have measured the power dissipated for an equivalent flux of 1.6 kHz/cm sup 2 of through-going muons to be 650 mW/m sup 2.

  3. Calculation of displacement and helium production at the LAMPF irradiation facility

    International Nuclear Information System (INIS)

    Davidson, D.R.; Greenwood, L.R.; Sommer, W.F.; Wechsler, M.S.

    1984-01-01

    Differential and total displacement and helium production rates are calculated for copper irradiated by spallation neutrons and 760 MeV protons at LAMPF. The calculations are performed using the SPECTER and VNMTC computer codes, the latter being specially designed for spallation radiation damage calculations. For comparison, similar SPECTER calculations are also described for irradiation of copper in EBR-II and RTNS-II. The results indicate substantial contributions to the displacement and helium production rates due to neutrons in the high-energy tail (above 40 MeV) of the LAMPF spallation neutron spectrum. Still higher production rates are calculated for irradiations in the direct proton beam. These results will provide useful background information for research to be conducted at a new irradiation facility at LAMPF

  4. Non-destructive tests of capsules for JMTR irradiation examination

    International Nuclear Information System (INIS)

    Tanaka, Hidetaka; Nagao, Yoshiharu; Sato, Masashi; Osawa, Kenji

    2007-03-01

    Irradiation examination are increasing in advanced irradiation research for accurate prediction control and evaluation of irradiation parameter such as neutron fluence, etc. by using JMTR. Irradiation capsule internals are therefore structurally complicated recently. This report described the procedure of non destructive tests such as radiographic test, penetrant test, ultrasonic test, etc. for inspection of irradiation capsules in JMTR, and the result of Test-case of confirmation procedure for internal parts of irradiation capsules. (author)

  5. Facility for fast neutron irradiation tests of electronics at the ISIS spallation neutron source

    International Nuclear Information System (INIS)

    Andreani, C.; Pietropaolo, A.; Salsano, A.; Gorini, G.; Tardocchi, M.; Paccagnella, A.; Gerardin, S.; Frost, C. D.; Ansell, S.; Platt, S. P.

    2008-01-01

    The VESUVIO beam line at the ISIS spallation neutron source was set up for neutron irradiation tests in the neutron energy range above 10 MeV. The neutron flux and energy spectrum were shown, in benchmark activation measurements, to provide a neutron spectrum similar to the ambient one at sea level, but with an enhancement in intensity of a factor of 10 7 . Such conditions are suitable for accelerated testing of electronic components, as was demonstrated here by measurements of soft error rates in recent technology field programable gate arrays

  6. Performance testing of beta dosimeters used at Department of Energy facilities

    International Nuclear Information System (INIS)

    Roberson, P.L.; Holbrook, K.L.; Pappin, J.L.

    1983-01-01

    A performance test based on the American national draft standard N13.11 was conducted for dosimeter systems in use at Department of Energy facilities. The large differences in dosimeter response found were due to use of different calibration source standards and different dosimeter designs. Differences in 90 Sr/ 90 Y calibrations were approximately 20% or less for all but one participant. The differences observed were attributed to variable thicknesses of dosimeter elements and variable source irradiation geometries. Improved beta calibration standards will result if irradiation specifications include acceptable ranges from the depth-dose characteristics. The low-energy beta responses observed were consistent with the thicknesses of dosimeter sensitive elements and overlying filtration

  7. Irradiation tests of ITER candidate Hall sensors using two types of neutron spectra

    International Nuclear Information System (INIS)

    Duran, I.; Bolshakova, I.; Holyaka, R.; Viererbl, L.; Lahodova, Z.; Sentkerestiova, J.; Bem, P.

    2010-01-01

    We report on irradiation tests of InSb based Hall sensors at two irradiation facilities with two distinct types of neutron spectra. One was a fission reactor neutron spectrum with a significant presence of thermal neutrons, while another one was purely fast neutron field. Total neutron fluence of the order of 10 16 cm -2 was accumulated in both cases, leading to significant drop of Hall sensor sensitivity in case of fission reactor spectrum, while stable performance was observed at purely fast neutron spectrum. This finding suggests that performance of this particular type of Hall sensors is governed dominantly by transmutation. Additionally, it further stresses the need to test ITER candidate Hall sensors under neutron flux with ITER relevant spectrum.

  8. Reflooding phenomena of German PWR estimated from CCTF [Cylindrical Core Test Facility], SCTF [Slab Core Test Facility] and UPTF [Upper Plenum Test Facility] results

    International Nuclear Information System (INIS)

    Murao, Y.; Iguchi, T.; Sugimoto, J.

    1988-09-01

    The reflooding behavior in a PWR with a combined injection type ECCS was studied by comparing the test results from Cylindrical Core Test Facility (CCTF), Slab Core Test Facility (SCTF) and Upper Plenum Test Facility (UPTF). Core thermal-hydraulics is discussed mainly based on SCTF test data. In addition, the water accumulation behavior in hot legs and the break-through characteristics at tie plate are discussed

  9. Use of the National Low-Temperature Neutron Irradiation Facility (NLTNIF) for fusion materials research

    International Nuclear Information System (INIS)

    Coltman, R.R. Jr.; Kerchner, H.R.; Klabunde, C.E.

    1986-01-01

    In May 1983 the Division of Materials Sciences, Office of Basic Energy Sciences of the Department of Energy authorized the establishment of a National Low-Temperature Neutron Irradiation Facility (NLTNIF) at ORNL's Bulk Shielding Reactor (BSR). The NLTNIF, which will be available for qualified experiments at no cost to users, will provide a combination of high radiation intensities and special environmental and testing conditions that have not been previously available in the US. Since the DOE authorization, work has proceeded on the design and construction of the new facility without interruption. This report describes the present status of the development of NLTNIF and, for the information of new candidate users, a recounting of the major specifications and capabilities is also given

  10. Welding of metallic fuel elements for the irradiation test in JOYO. Preliminary tests and welding execution tests (Joint research)

    International Nuclear Information System (INIS)

    Kikuchi, Hironobu; Nakamura, Kinya; Iwai, Takashi; Arai, Yasuo

    2009-10-01

    Irradiation tests of metallic fuels elements in fast test reactor JOYO are planned under the joint research of Japan Atomic Energy Agency (JAEA) and Central Research Institute of Electric Power Industry (CRIEPI). Six U-Pu-Zr fuel elements clad with ferritic martensitic steel are fabricated in Plutonium Fuel Research Facility (PFRF) of JAEA-Oarai for the first time in Japan. In PFRF, the procedures of fabrication of the fuel elements were determined and the test runs of the equipments were carried out before the welding execution tests for the fuel elements. Test samples for confirming the welding condition between the cladding tube and top and bottom endplugs were prepared, and various test runs were carried out before the welding execution tests. As a result, the welding conditions were finalized by passing the welding execution tests. (author)

  11. National Solar Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The National Solar Thermal Test Facility (NSTTF) is the only test facility in the United States of its type. This unique facility provides experimental engineering...

  12. An estimate of radiation fields in a gamma irradiation facility using fuel elements from a swimming pool reactor

    International Nuclear Information System (INIS)

    Narain, Rajendra

    2002-01-01

    A simple gamma irradiation facility set up using a few irradiated or partially irradiated swimming pool elements can be assembled to provide a convenient facility for irradiation of small and medium sized samples for research. The paper presents results of radiation levels with an arrangement using four elements from a reactor core operating at a power of 20 MW. A maximum gamma field of higher than 1 KGy/h at locations adjacent to fuel elements with negligible neutron contamination can be achieved. (author)

  13. Design and selection criteria of a commercial irradiation facility for spices and dry products

    International Nuclear Information System (INIS)

    Aggarwal, K.S.

    1990-01-01

    Apart from cost considerations, various factors which should be taken into consideration in design of a commercial irradiation facility for spices and dry products and the factors which a user should consider for selecting a food irradiator are discussed in brief. (author)

  14. Liquefied Gaseous Fuels Spill Test Facility

    International Nuclear Information System (INIS)

    1993-02-01

    The US Department of Energy's liquefied Gaseous Fuels Spill Test Facility is a research and demonstration facility available on a user-fee basis to private and public sector test and training sponsors concerned with safety aspects of hazardous chemicals. Though initially designed to accommodate large liquefied natural gas releases, the Spill Test Facility (STF) can also accommodate hazardous materials training and safety-related testing of most chemicals in commercial use. The STF is located at DOE's Nevada Test Site near Mercury, Nevada, USA. Utilization of the Spill Test Facility provides a unique opportunity for industry and other users to conduct hazardous materials testing and training. The Spill Test Facility is the only facility of its kind for either large- or small-scale testing of hazardous and toxic fluids including wind tunnel testing under controlled conditions. It is ideally suited for test sponsors to develop verified data on prevention, mitigation, clean-up, and environmental effects of toxic and hazardous gaseous liquids. The facility site also supports structured training for hazardous spills, mitigation, and clean-up. Since 1986, the Spill Test Facility has been utilized for releases to evaluate the patterns of dispersion, mitigation techniques, and combustion characteristics of select materials. Use of the facility can also aid users in developing emergency planning under US P.L 99-499, the Superfund Amendments and Reauthorization Act of 1986 (SARA) and other regulations. The Spill Test Facility Program is managed by the US Department of Energy (DOE), Office of Fossil Energy (FE) with the support and assistance of other divisions of US DOE and the US Government. DOE/FE serves as facilitator and business manager for the Spill Test Facility and site. This brief document is designed to acquaint a potential user of the Spill Test Facility with an outline of the procedures and policies associated with the use of the facility

  15. A high field and cryogenic test facility for neutron irradiated superconducting wire

    Science.gov (United States)

    Nishimura, A.; Miyata, H.; Yoshida, M.; Iio, M.; Suzuki, K.; Nakamoto, T.; Yamazaki, M.; Toyama, T.

    2017-12-01

    A 15.5 T superconducting magnet and a variable temperature insert (VTI) system were installed at a radiation control area in Oarai center in Tohoku University to investigate the superconducting properties of activated superconducting materials by fast neutron. The superconductivity was measured at cryogenic temperature and high magnetic field. During these tests, some inconvenient problems were observed and the additional investigation was carried out. The variable temperature insert was designed and assembled to perform the superconducting property tests. without the liquid helium. To remove the heat induced by radiation and joule heating, high purity aluminum rod was used in VTI. The thermal contact was checked by FEM analysis and an additional support was added to confirm the decreasing the stress concentration and the good thermal contact. After the work for improvement, it was affirmed that the test system works well and all troubles were resolved. In this report, the improved technical solution is described and the first data set on the irradiation effect on Nb3Sn wire is presented.

  16. Operation of post-irradiation examination facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, E. G.; Jeon, Y. B.; Ku, D. S.

    1996-12-01

    In 1996, the post-irradiation examination(PIE) of nuclear fuels was performed as follows. It has been searched for the caution of defection of defected fuel rods of Youngkwang-4 reactor through NDT and metallographic examination that had been required by KEPCO. And in-pool inspection of Kori-1 spent fuel assembly(FO2) was carried out. HVAC system and pool water treatment system have been operated to maintain the facility safely, and electric power supply system was checked and maintained for the normal and steady supply electric power to the facility. Image processing software was developed for measurement of defection of spent fuel rods. Besides, a radiation shielding glove box was fabricated and a hot cell compressor for volume reduction of radioactive materials was fabricated and installed in hot cell. Safeguards of nuclear materials were implemented in strict accordance with the relevant Korean rules and regulations as well as the international non-proliferation regime. Also the IAEA inspection was carried out on the quarterly basis. (author). 31 tabs., 71 figs., 4 refs.

  17. TESTING OF GAS REACTOR MATERIALS AND FUEL IN THE ADVANCED TEST REACTOR

    International Nuclear Information System (INIS)

    Grover, S.B.

    2004-01-01

    The Advanced Test Reactor (ATR) has long been involved in testing gas reactor materials, and has developed facilities well suited for providing the right conditions and environment for gas reactor tests. This paper discusses the different types of irradiation hardware that have been utilized in past ATR irradiation tests of gas reactor materials. The new Gas Test Loop facility currently being developed for the ATR is discussed and the different approaches being considered in the design of the facility. The different options for an irradiation experiment such as active versus passive temperature control, neutron spectrum tailoring, and different types of lead experiment sweep gas monitors are also discussed. The paper is then concluded with examples of different past and present gas reactor material and fuel irradiations

  18. Testing of Gas Reactor Materials and Fuel in the Advanced Test Reactor

    International Nuclear Information System (INIS)

    S. Blaine Grover

    2004-01-01

    The Advanced Test Reactor (ATR) has long been involved in testing gas reactor materials, and has developed facilities well suited for providing the right conditions and environment for gas reactor tests. This paper discusses the different types of irradiation hardware that have been utilized in past ATR irradiation tests of gas reactor materials. The new Gas Test Loop facility currently being developed for the ATR is discussed and the different approaches being considered in the design of the facility. The different options for an irradiation experiment such as active versus passive temperature control, neutron spectrum tailoring, and different types of lead experiment sweep gas monitors are also discussed. The paper is then concluded with examples of different past and present gas reactor material and fuel irradiations

  19. Future proton and mixed-field irradiation facilities with slow extraction for LHC operation phase and for LHC upgrades

    CERN Document Server

    Assmann, Ralph Wolfgang; Brugger, Markus; Efthymiopoulos, Ilias; Feldbaumer, Eduard; Garrido, Mar Capeans; Glaser, Maurice; Kramer, Daniel; Linssen, Lucie; Losito, Roberto; Moll, Michael; Rembser, Christoph; Silari, Marco; Thurel, Yves; Tsesmelis, Emmanuel; Vincke, Helmut; CERN. Geneva. The LHC experiments Committee; LHCC

    2010-01-01

    In the present proposal we present the need for improved proton and mixed-field irradiation facilities with slow beam extraction at CERN. Strong needs are expressed by both the detector and accelerator communities and concern the LHC operation era as well as the upgrades of machine and experiments. The current facilities and test areas have a number of limitations and drawbacks. Preliminary studies indicate that there are possibilities for a coherent and cost-effective approach towards improved facilities for the future. The aim of this document is to inform the LHCC and seek its recognition for the need of such facilities. In addition we would appreciate the support of the LHCC for pursuing further implementation studies at a PS East Hall location.

  20. Probing and irradiation tests of ALICE pixel chip wafers and sensors

    CERN Document Server

    Cinausero, M; Antinori, F; Chochula, P; Dinapoli, R; Dima, R; Fabris, D; Galet, G; Lunardon, M; Manea, C; Marchini, S; Martini, S; Moretto, S; Pepato, Adriano; Prete, G; Riedler, P; Scarlassara, F; Segato, G F; Soramel, F; Stefanini, G; Turrisi, R; Vannucci, L; Viesti, G

    2004-01-01

    In the framework of the ALICE Silicon Pixel Detector (SPD) project a system dedicated to the tests of the ALICE1LHCb chip wafers has been assembled and is now in use for the selection of pixel chips to be bump-bonded to sensor ladders. In parallel, radiation hardness tests of the SPD silicon sensors have been carried out using the 27 MeV proton beam delivered by the XTU TANDEM accelerator at the SIRAD facility in LNL. In this paper we describe the wafer probing and irradiation set-ups and we report the obtained results. (6 refs).

  1. Reconstruction of exposures to the public from a cobalt-60 irradiator facility

    International Nuclear Information System (INIS)

    Chapman, T.E.; Scherpelz, R.I.

    1992-01-01

    A study was performed for the US Department of Energy (DOE) to assess the radiation exposure received by the public from the operation of a cobalt-60 irradiator facility. Located south of Davis, California, at the former Laboratory for Energy-Related Health Research, the facility was an indoor-outdoor gamma irradiator operated for the DOE by the University of California, Davis. From 1970 to 1985, outdoor radiation exposure experiments conducted at the facility resulted in environmental radiation doses of 80 to 120 mSv per year along the facility's perimeter fence. Comprehensive environmental monitoring was not performed in the adjacent, uncontrolled areas and personnel who occupied these areas were not routinely monitored for radiation exposure. Because of incomplete environmental monitoring data, computer modeling was required to reconstruct the environmental dose rates present when the facility was in operation. Personnel occupancy times for the adjacent areas were determined from population statistics, historical records, and personal interviews. The potential dose equivalents calculated for the individuals who lived or worked in neighboring areas ranged from 0.02 to 3.6 mSv per year. These exposures, some of which exceed the current DOE standard of 1 mSv/y, were less than the DOE regulatory limit of 5 mSv/y for exposure to the public that was in effect when the facility was in operation

  2. RECH-1 test fuel irradiation status report

    International Nuclear Information System (INIS)

    Marin, J.; Lisboa, J.; Olivares, L.; Chavez, J.

    2005-01-01

    Since May 2003, one RECH-1 fuel element has been submitted to irradiation at the HFR-Petten, Holland. By November 2004 the irradiation has achieved its pursued goal of 55% burn up. This irradiation qualification service will finish in the year 2005 with PIE tests, as established in a contractual agreement between the IAEA, NRG, and CCHEN. This report presents the objectives and the current results of this fuel qualification under irradiation. Besides, a brief description of CHI/4/021, IAEA's Technical Cooperation Project that has supported this irradiation test, is also presented here. (author)

  3. Ion-Neutron Irradiated BOR60 Sample Preparation and Characterization: Nuclear Science User Facility 2017 Milestone Report

    Energy Technology Data Exchange (ETDEWEB)

    Linton, Kory D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Parish, Chad M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Smith, Quinlan B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    This document outlines the results obtained by Oak Ridge National Laboratory (ORNL) in collaboration with the University of Michigan-led Consolidated Innovative Nuclear Research project, “Feasibility of combined ion-neutron irradiation for accessing high dose levels.” In this reporting period, neutron irradiated were prepared and shipped to the University of Michigan for subsequent ion irradiation. The specimens were returned to ORNL’s Low Activation Materials Development and Analysis facility, prepared via focused ion beam for examination using scanning/transmission electron microscopy (S/TEM), and then examined using S/TEM to measure the as-irradiated microstructure. This report briefly summarizes the S/TEM results obtained at ORNL’s Low Activation Materials Development and Analysis facility.

  4. Structural Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides a wide variety of testing equipment, fixtures and facilities to perform both unique aviation component testing as well as common types of materials testing...

  5. Disk-bend ductility tests for irradiated materials

    International Nuclear Information System (INIS)

    Klueh, R.L.; Braski, D.N.

    1984-01-01

    We modified the HEDL disk-bend test machine and are using it to qualitatively screen alloys that are susceptible to embrittlement caused by irradiation. Tests designed to understand the disk-bend test in relation to a uniaxial test are discussed. Selected results of tests of neutron-irradiated material are also presented

  6. Survey of solar thermal test facilities

    Energy Technology Data Exchange (ETDEWEB)

    Masterson, K.

    1979-08-01

    The facilities that are presently available for testing solar thermal energy collection and conversion systems are briefly described. Facilities that are known to meet ASHRAE standard 93-77 for testing flat-plate collectors are listed. The DOE programs and test needs for distributed concentrating collectors are identified. Existing and planned facilities that meet these needs are described and continued support for most of them is recommended. The needs and facilities that are suitable for testing components of central receiver systems, several of which are located overseas, are identified. The central contact point for obtaining additional details and test procedures for these facilities is the Solar Thermal Test Facilities Users' Association in Albuquerque, N.M. The appendices contain data sheets and tables which give additional details on the technical capabilities of each facility. Also included is the 1975 Aerospace Corporation report on test facilities that is frequently referenced in the present work.

  7. Irradiation enhanced diffusion and irradiation creep tests in stainless steel alloys

    International Nuclear Information System (INIS)

    Loelgen, R.H.; Cundy, M.R.; Schuele, W.

    1977-01-01

    A review is given of investigations on the rate of phase changes during neutron and electron irradiation in many different fcc alloys showing either precipitation or ordering. The diffusion rate was determined as a function of the irradiation flux, the irradiation temperature and the irradiation dose. It was found that the radiation enhanced diffusion in all the investigated alloys is nearly temperature independent and linearly dependent on the flux. From these results conclusions were drawn concerning the properties of point defects and diffusion mechanisms rate determining during irradiation, which appears to be of a common nature for fcc alloys having a similar structure to those investigated. It has been recognized that the same dependencies which are found for the diffusion rate were also observed for the irradiation creep rate in stainless steels, as reported in literature. On the basis of this obervation a combination of measurements is suggested, of radiation enhanced diffusion and radiation enhanced creep in stainless steel alloys. Measurements of radiation enhanced diffusion are less time consuming and expensive than irradiation creep tests and information on this property can be obtained rather quickly, prior to the selection of stainless steel alloys for creep tests. In order to investigate irradiation creep on many samples at a time two special rigs were developed which are distinguished only by the mode of stress applied to the steel specimens. Finally, a few uniaxial tensile creep tests will be performed in fully instrumented rigs. (Auth.)

  8. Irradiation tests report of the 32nd cycle in 'JOYO'

    International Nuclear Information System (INIS)

    1998-09-01

    This report summarizes the operating and irradiation data of the experimental reactor 'JOYO' 32nd cycle, and estimates the 33rd cycle irradiation condition. Irradiation tests in the 31st cycle are as follows: (1) B-type irradiation rig (B9). (a) High burn up performance tests of MONJU' fuel pins, advanced austenitic steel cladding fuel pins, large diameter fuel pins, ferrite steel cladding fuel pins (in collaboration with the USA) and large diameter annular pellet fuel pins. (b) Mixed carbide and nitride fuel pins irradiation tests (in collaboration with JAERI). (2) C-type irradiation rig (C4F). (a) High burn up performance test of advanced austenitic steel cladding fuel pins (in collaboration with France). (3) C-type irradiation rig (C6D). (a) Large diameter fuel pins irradiation test. (4) Absorber Materials Irradiation Rig (AMIR-6). (a) Run to absorber pin's cladding breach. (5) Absorber Materials Irradiation Rig (AMIR-8). (a) High-temperature shroud and Na-bond elements tests. (6) Core Materials Irradiation Rig (CMIR-5-1). (a) Core materials irradiation tests. (7) Structure Materials Irradiation Rigs (SMIR). (a) Material irradiation tests (in collaboration with universities). (b) Surveillance back up tests for MONJU'. (8) MAterial testing RIg with temperature COntrol (MARICO-1). (a) Material irradiation tests (in collaboration with universities), (b) Creep rupture tests of the core materials for the demonstration reactor. (9) Upper core structure irradiation Plug Rig (UPR-1-5). (a) Upper core neutron spectrum effect and accelerated irradiation effect. The maximum burn-up driver assembly 'PFD503' reached 65,600 MWd/t (pin average). (author)

  9. Design of small-animal thermal neutron irradiation facility at the Brookhaven Medical Research Reactor

    International Nuclear Information System (INIS)

    Liu, H.B.

    1996-01-01

    The broad beam facility (BBF) at the Brookhaven Medical Research Reactor (BMRR) can provide a thermal neutron beam with flux intensity and quality comparable to the beam currently used for research on neutron capture therapy using cell-culture and small-animal irradiations. Monte Carlo computations were made, first, to compare with the dosimetric measurements at the existing BBF and, second, to calculate the neutron and gamma fluxes and doses expected at the proposed BBF. Multiple cell cultures or small animals could be irradiated simultaneously at the so-modified BBF under conditions similar to or better than those individual animals irradiated at the existing thermal neutron irradiation Facility (TNIF) of the BMRR. The flux intensity of the collimated thermal neutron beam at the proposed BBF would be 1.7 x 10 10 n/cm 2 ·s at 3-MW reactor power, the same as at the TNIF. However, the proposed collimated beam would have much lower gamma (0.89 x 10 -11 cGy·cm 2 /n th ) and fast neutron (0.58 x 10 -11 cGy·cm 2 /n th ) contaminations, 64 and 19% of those at the TNIF, respectively. The feasibility of remodeling the facility is discussed

  10. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y H; Cho, M S [and others

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  11. Design of an irradiation facility with thermal, epithermal and fast neutron beams

    International Nuclear Information System (INIS)

    Pfister, G.; Bernnat, W.; Seidel, R.; Schatz, A.K.; Wagner, F.M.; Waschkowski, W.; Schraube, H.

    1992-01-01

    The main features of a neutron irradiation facility to be installed at the planned research reactor FRM-II are presented. In addition to the operational possibilities of the existing facility at the reactor FRM-I, the new facility will produce quasi-monoenergetic neutron fields and a neutron beam in the keV region whose spectrum can be modified by application of suitable filters and scatterers. For this beam, which is well suited for boron capture therapy, calculated boron reaction rates inside a phantom and an experimental verification of the calculations at the existing facility are presented. (orig.) [de

  12. Instrumentation to Enhance Advanced Test Reactor Irradiations

    Energy Technology Data Exchange (ETDEWEB)

    J. L. Rempe; D. L. Knudson; K. G. Condie; J. E. Daw; S. C. Taylor

    2009-09-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR will support basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors has been completed. Based on this review, recommendations are made with respect to what instrumentation is needed at the ATR and a strategy has been developed for obtaining these sensors. Progress toward implementing this strategy is reported in this document. It is anticipated that this report will be updated on an annual basis.

  13. Instrumentation to Enhance Advanced Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Rempe, J.L.; Knudson, D.L.; Condie, K.G.; Daw, J.E.; Taylor, S.C.

    2009-01-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR will support basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors has been completed. Based on this review, recommendations are made with respect to what instrumentation is needed at the ATR and a strategy has been developed for obtaining these sensors. Progress toward implementing this strategy is reported in this document. It is anticipated that this report will be updated on an annual basis.

  14. Pagure {sup 60}Co panoramic irradiation facility; Pagure irradiateur panoramique au {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Puig, J R; Laizier, J; Lorin, M; Laroche, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    After a description of the various parts of 'PAGURE', a 10 KCi panoramic irradiation facility, and of the operations data, a critic scrutiny is given. From the experience of five years operations, working of the facility can be thought of very satisfying. From the point of view of standardization of irradiation facilities, PAGURE can be taken, in its range, as a standard design. (authors) [French] Apres avoir decrit les differents elements constitutifs de 1'irradiateur panoramique de 10 KCi 'PAGURE' et precise les donnees d'exploitation, on en fait l'examen critique. A la lumiere de cinq annees d'utilisation, le fonctionnement de 1'irradiateur apparait extremement satisfaisant. Dans une perspective de standardisation des appareils, on peut, dans sa gamme, le considerer comme une realisation type. (auteurs)

  15. Source rack reload of the Tunisian gamma irradiation facility using Monte Carlo method

    International Nuclear Information System (INIS)

    Gharbi, Foued; Kadri, Omrane

    2005-01-01

    This work presents a Monte Carlo study of the cylindrical source rack geometry of the tunisian gamma irradiation facility, using Ge ant code of CERN. The study investigates the question of the reload of the source rack. studied configurations consist on housing four new pencils, two in the upper and two in the lower cylinder of the source rack. global dose rate uniformity inside a ''dummy's' product for the case of routine and non routine irradiation and as function of the product bulk density was calculated for eight hypothetical configurations. the same calculation was also performed for both of the original and the ideal, but not practical configuration. It was shown that hypothetical cases produced dose uniformity variations, according to product density, that were statistically no different than the original and the ideal configurations and that reload procedure can not improve the irradiation quality inside the tunisian facility

  16. The Integral Test Facility Karlstein

    Directory of Open Access Journals (Sweden)

    Stephan Leyer

    2012-01-01

    Full Text Available The Integral Test Facility Karlstein (INKA test facility was designed and erected to test the performance of the passive safety systems of KERENA, the new AREVA Boiling Water Reactor design. The experimental program included single component/system tests of the Emergency Condenser, the Containment Cooling Condenser and the Passive Core Flooding System. Integral system tests, including also the Passive Pressure Pulse Transmitter, will be performed to simulate transients and Loss of Coolant Accident scenarios at the test facility. The INKA test facility represents the KERENA Containment with a volume scaling of 1 : 24. Component heights and levels are in full scale. The reactor pressure vessel is simulated by the accumulator vessel of the large valve test facility of Karlstein—a vessel with a design pressure of 11 MPa and a storage capacity of 125 m3. The vessel is fed by a benson boiler with a maximum power supply of 22 MW. The INKA multi compartment pressure suppression Containment meets the requirements of modern and existing BWR designs. As a result of the large power supply at the facility, INKA is capable of simulating various accident scenarios, including a full train of passive systems, starting with the initiating event—for example pipe rupture.

  17. Design verification test of instrumented capsule (02F-11K) for nuclear fuel irradiation in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Sohn, J. M.; Oh, J. M. [and others

    2004-01-01

    An instrumented capsule is being developed to be able to measure fuel characteristics, such as fuel temperature, internal pressure of fuel rod, fuel elongation, and neutron flux, etc., during the irradiation test of nuclear fuel in HANARO. The instrumented capsule for measuring and monitoring fuel centerline temperature and neutron flux was designed and manufactured. The instrumented capsule includes three test fuel rods installed thermocouple to measure fuel centerline temperature and three SPNDs (Self-Powered Neutron Detector) to monitor the neutron flux. Its stability was verified by out-of-pile performance test, and its safety evaluation was also shown that the safety requirements were satisfied. And then, to verify the design of the instrumented capsule in the test hole, it was successfully irradiated in the test hole of HANARO from March 14, 2003 to June 1, 2003 (53.8 full power days at 24 MWth). During irradiation, the centerline temperature of PWR UO{sub 2} fuel pellets fabricated by KEPCO Nuclear Fuel Company and the neutron flux were continuously measured and monitored. The test fuel rods were irradiated at less than 350 W/cm to 5.13 GWD/MTU with fuel centerline peak temperature below 1,375 .deg. C. The structural stability of the capsule was satisfied by the naked eye in service pool of HANARO. The capsule and test fuel rods were dismantled and test fuel rods were examined at the hot cell of IMEF (Irradiated Material Examination Facility)

  18. Irradiation setup at the U-120M cyclotron facility

    Czech Academy of Sciences Publication Activity Database

    Křížek, Filip; Ferencei, Jozef; Matlocha, Tomáš; Pospíšil, Jan; Príbeli, Peter; Raskina, Valentina; Isakov, Artem; Štursa, Jan; Vaňát, Tomáš; Vysoká, K.

    2018-01-01

    Roč. 894, č. 6 (2018), s. 87-95 ISSN 0168-9002 R&D Projects: GA MŠk LM2015056; GA MŠk LM2015058 Institutional support: RVO:61389005 Keywords : particle irradiation facility * radiation hardness * dosimetry * single event effect * single event upset * single event transient Subject RIV: BG - Nuclear, Atomic and Molecular Physics , Colliders OBOR OECD: Nuclear physics Impact factor: 1.362, year: 2016

  19. Implementing an environmental management system in a irradiation facility

    International Nuclear Information System (INIS)

    O'Doherty, James

    1998-01-01

    Environmental management is at different stages in the countries where there are commercial irradiation facilities. There are therefore differing perspectives on the role of an Environmental Management System, ranging from compliance with the Regulatory framework to a desire to be proactive. An effective Environmental Management System (EMS) facilitates compliance, while also providing the framework for assessment and improvement of a company's environmental impact and overall performance

  20. GPS Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Global Positioning System (GPS) Test Facility Instrumentation Suite (GPSIS) provides great flexibility in testing receivers by providing operational control of...

  1. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y. H.; Cho, M. S. (and others)

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  2. High-energy, twelve-channel laser facility (DEFIN) for spherical irradiation of thermonuclear targets

    International Nuclear Information System (INIS)

    Basov, N.G.; Danilov, A.E.; Krokhin, O.N.; Kruglov, B.V.; Mikhailov, Yu.A.; Sklizkov, G.V.; Fedotov, S.I.; Fedorov, A.N.

    This paper describes a high-energy, twelve-channel laser facility (DELFIN) intended for high-temperature heating of thermonuclear targets with spherical symmetry. The facility includes a neodymium-glass laser with the ultimate radiation energy of 10 kJ, a pulse length of approximately 10 -10 to 10 -9 s, beam divergence of 5 x 10 -4 radians, a vacuum chamber in which laser radiation interacts with the plasma, and a system of diagnostic instrumentation for the observation of laser beam and plasma parameters. Described are the optical scheme and construction details of the laser facility. Presented is an analysis of focusing schemes for target irradiation and described is the focusing scheme of the DELFIN facility, which is capable of attaining a high degree of spherical symmetry in irradiating targets with maximum beam intensity at the target surface of approximately 10 15 W/cm 2 . This paper examines the most important problems connected with the physical investigations of thermonuclear laser plasma and the basic diagnostic problems involved in their solution

  3. Monte Carlo based demonstration of sufficiently dimensioned shielding for a Co-60 testing facility

    International Nuclear Information System (INIS)

    Wind, Michael; Beck, Peter; Latocha, Marcin

    2015-01-01

    The electrical properties of electronic equipment can be changed in an ionized radiation field. The knowledge of these changes is necessary for applications in space, in air traffic and nuclear medicine. Experimental tests will be performed in Co-60 radiation fields in the irradiation facility (TEC facility) of the Seibersdorf Labor GmbH that is in construction. The contribution deals with a simulation that is aimed to calculate the local dose rate within and outside the building for demonstration of sufficient dimensioning of the shielding in compliance with the legal dose rate limits.

  4. External irradiation facilities open for biological studies - progress in july 2005

    International Nuclear Information System (INIS)

    Gaillard-Lecanu, E.; Authier, N.; Verrey, B.; Bailly, I.; Bordy, J.M.; Coffigny, H.; Cortela, L.; Duval, D.; Leplat, J.J.; Poncy, J.L.; Testard, I.; Thuret, J.Y.

    2005-01-01

    The Life Science Division of the Atomic Energy Commission is making an inventory of the various radiation sources accessible for investigation on the biological effects of ionizing radiation. In this field, a wide range of studies is being carried out at the Life Science Division, attempting to characterize the kind of lesions with their early biological consequences (on the various cell compartments) and their late biological consequences (deterministic or stochastic effects), in relation to the radiation type and dose, especially at low doses. Several experimental models are available: plants, bacteria, eukaryotic cells from yeast up to mammalian cells and in vivo studies, mostly on rodents, in order to characterize the somatic late effects and the hereditary effects. Due to the significant cost of these facilities, also to their specific properties (nature of the radiation, dose and dose rate, possible accuracy of the irradiation at the molecular level), the closeness is no longer the only criteria for biologists to make a choice. The current evolution is to set up irradiation infrastructures combining ionizing radiation sources themselves and specific tools dedicated to biological studies: cell or molecular biology laboratories, animal facilities. The purpose, in this new frame, is to provide biologists with the most suitable facilities, and, if possible, to change these facilities according to requirements in radiobiology. In this report, the basics of interactions of ionizing radiation with biological tissues are briefly introduced, followed by a presentation of some of the facilities available for radiobiological studies especially at CEA. This panorama is not a comprehensive one, new data will be included as they advance, whether reporting existing facilities or if a new one is developed. (authors)

  5. Aging and rate effects of the Multigap RPC studied at the Gamma Irradiation Facility at CERN

    CERN Document Server

    Alici, A; Kim, J; Hatzifotiadou, D; Sun, Y; Valenti, G; Williams, M C S; Yakorev, D; Zichichi, A

    2007-01-01

    The selected device for the ALICE Time-of-Flight array is the Multigap Resistive Plate Chamber (MRPC). Previously we have tested this device at the Gamma Irradiation Facility (GIF) at CERN to evaluate the rate dependence; we have now performed additional tests using the final design of the MRPC and with a gas mixture free of hydrocarbons. We have measured the performance of the MRPC up to an equivalent flux of minimum ionizing muons of 2.5 kHz/cm2. We also present results from an aging test obtained by exposing two MRPC strips to the GIF source for a period of six months.

  6. Reactivity anomalies in the FFTF [Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Knutson, B.J.; Harris, R.A.

    1987-04-01

    Experience using an automated core reactivity monitoring technique at the Fast Flux Test Facility (FFTF) through eight operating cycles is described. This technique relies on comparing predicted to measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. Reactivity worth predictions of core state changes (e.g., temperature and irradiation changes) and compensating control rod movements are required for the rod position comparison. A substantial data base now exists to evaluate changes in temperature reactivity feedback effects operational in the FFTF, rod worth changes due to core loading, temperature and irradiation effects and burnup effects associated with transmutation of fuel materials. This report summarizes preliminary work of correlating zero power and at-power rod worth measurement data, calculated burnup rates and rod worths using the latest ENDF/B-V cross section set for each cycle to evaluate the prediction models and attempt to resolve observed reactivity anomalies. 2 figs., 2 tabs

  7. Prospects of establishing food irradiation facilities in Kenya

    International Nuclear Information System (INIS)

    Mustapha, A.O.; Patel, J.P.; Rathore, I.V.S.; Hashim, N.O.; Kinyua, A.M.

    2001-01-01

    Full text: A national project of food irradiation in the country is being proposed. At present there are no facilities for food irradiation (and food irradiation research) in Kenya. This report is therefore largely comparative between the traditional and the conventional food preservation methods on the one hand and the irradiation technique on the other. The report is also based on information from other countries where food irradiation is practiced (Kawabata, 1981) or is being also contemplated (Diop et al, 1997), as well as on the relevant report of the International Atomic Energy Agency (IAEA) on this topic (IAEA, 1993). The paper presents the statement of the research problem, i.e., in Kenya large quantities of food and other farm produces go to waste annually as a result of the inadequacies of the preservation techniques currently in use. These (other) preservation techniques, although often less controversial than the irradiation techniques, have also been found to be more expensive to run when compared to irradiation techniques. Such techniques, presently employed in Kenya, include the traditional methods (e.g. sun drying, smoke and fire drying, etc.) and modern techniques such as freezing or refrigeration, lyophilization, etc., as well as application of chemicals like insecticides and fumigants. The latter combines the disadvantages of high costs with environmental pollution and associated health risks. In this preliminary research, aimed at studying the prospects of a national food irradiation project, the following food items that are selected for their importance to the economy of the country, include potatoes, rice, maize, coffee, tea, various fruits, fish and meat. The paper also explores the economic feasibility as well as the human and technological requirements of establishing a commercial food irradiation plant, with aim of assessing the applicability of food irradiation as alternative or a complimentary approach for preservation technique in

  8. Energy Systems Test Area (ESTA). Power Systems Test Facilities

    Science.gov (United States)

    Situ, Cindy H.

    2010-01-01

    This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.

  9. Post irradiation examination technology exchange

    International Nuclear Information System (INIS)

    Sozawa, Shizuo; Ito, Masayasu; Taguchi, Taketoshi; Nakagawa, Tetsuya; Lee, Hyung-Kwon

    2012-01-01

    Under the KAERI and JAEA agreement, in a part of the program 18 (Post Irradiation Examination (PIE) and Evaluation Technique of Irradiated Materials), an eddy current test was proposed as a round robin test, and it has been being progressed in both organizations in order to enhance the post irradiation examination technology. Up to now, several data are obtained by both PIE facilities. In this paper, the round robin test program is shown, and also shown obtained data with discussion from applicability as a nondestructive test in the hot cell. (author)

  10. Performance studies under high irradiation of resistive bulk-micromegas chambers at the CERN Gamma Irradiation Facility

    CERN Document Server

    Sidiropoulou, Ourania; Bortfeldt, J; Farina, E; Iengo, P; Longo, L; Sidiropoulou, O; Wotschack, J

    2017-01-01

    Radiation studies on several resistive bulk-Micromegas chambers produced at CERN will be viewed in this document. Two resistive bulk-Micromegas chambers have been installed at the CERN Gamma Irradiation Facility (GIF++) exposed to an intense gamma irradiation with the aim of evaluating the detector behaviour under high irradiation and carrying out a long-term age- ing study. The chambers under study have an active area of 10 x 10 cm 2 , a strip pitch of 400 m m , an ampli- fication gap of 128 m m , and a drift gap of 5 mm. The results on the detector performance as a function of the photon flux up to 44 MHz/cm 2 will be shown as well as the ageing properties as function of the integrated charge and the current intensity and its stability with time. In addition, the results of the efficiency measurements before, during, and after the irradiation will also be presented as a function of the amplification voltage at which the chambers are operated.

  11. DOE uses transportable irradiator for demonstration and testing

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    The U.S. Dept. of Energy's Pacific Northwest Laboratory (PNL), Richland, Washington (operated by Battelle Memorial Institute), has a transportable irradiator that was built to travel to various locations to demonstrate the benefits of low-dose irradiation for the processing of food. Part of a DOE program designed to establish irradiation facilities in Alaska, Florida, Hawaii, Iowa, Oklahoma, and Washington, the mobile unit can also be used for research, pilot-scale processing, operator training, and education. The irradiation unit consists of two lead-lined cylindrical chambers-an irradiation chamber and a source chamber-inside a steel casing. During operation, the item to be irradiated is placed inside the irradiation chamber, which is then rotated until a window in the chamber lines up with a screened window in the source chamber. The source chamber contains the transportation cask containing the four capsules of cesium-137 that are used as the source of gamma radiation. During operation, the lid of the cask is raised, pulling the capsules into operating position. In this alignment, the product is irradiated for a predetermined length of time. Then the lid of the cask is lowered and the irradiation chamber is rotated back to its original position for removal of the product

  12. Corrosion Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Corrosion Testing Facility is part of the Army Corrosion Office (ACO). It is a fully functional atmospheric exposure site, called the Corrosion Instrumented Test...

  13. Reactor cover gas monitoring at the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Bechtold, R.A.; Holt, F.E.; Meadows, G.E.; Schenter, R.E.

    1986-09-01

    The Fast Flux Test Facility (FFTF) is a 400-megawatt (thermal) sodium-cooled reactor designed for irradiation testing of fuels, materials and components for LMRs. It is operated by the Westinghouse Hanford Company for the US Department of Energy on the government-owned Hanford reservation near Richland, Washington. The first 100-day operating cycle began in April 1982 and the eighth operating cycle was completed in July 1986. Argon is used as the cover gas for all sodium systems at the plant. A program for cover gas monitoring has been in effect since the start of sodium fill in 1978. The argon is supplied to the FFTF by a liquid argon Dewar System and used without further purification

  14. Ballistic Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Ballistic Test Facility is comprised of two outdoor and one indoor test ranges, which are all instrumented for data acquisition and analysis. Full-size aircraft...

  15. Mechanical Tests Plan after Neutron Irradiation for SMART SG Tube Materials in a Hot Cell

    International Nuclear Information System (INIS)

    Ahn, Sang Bok; Baik, Seung Jai; Kim, Do Sik; Yoo, Byung Ok; Jung, Yang Hong; Song, Woong Sub; Choo, Kee Nam; Park, Jin Seok; Lee, Yong Sun; Ryu, Woo Seog

    2010-01-01

    An advanced integral PWR, SMART (System- Integrated Modular Advanced ReacTor) is being developed in KAERI. It has compact size and a relatively small power rating compared to a conventional reactor. The main components such as the steam generators, main circulation pumps are located in the reactor vessel. Therefore they are damaged from neutron irradiations generated from nuclear fuel fissions during operation. The SMART SG tubes which are 17 mm in a diameter and 2.5 mm in a thickness will be made of Alloy 690. To ensure the operation safety the post irradiation examinations is necessary to evaluate the deterioration levels of various original properties. Specially the amount of mechanical properties change should be reflected and revised to design data. For that tensile, fracture, hardness test are planned and under preparations. In this paper the detailed plans are reviewed. Three kinds of materials having different heat treatment procedures are prepared to fabricate specimens. The capsules installed the specimens are going to be irradiated in HANARO. Finally the tests for them will be performed in IMEF, Irradiated Materials Examination Facility at KAERI

  16. Distributed Energy Resources Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — NREL's Distributed Energy Resources Test Facility (DERTF) is a working laboratory for interconnection and systems integration testing. This state-of-the-art facility...

  17. Response of unirradiated and irradiated PWR fuel rods tested under power-cooling-mismatch conditions

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Quapp, W.J.; Martinson, Z.R.; McCardell, R.K.; Mehner, A.S.

    1978-01-01

    This report summarizes the results from the single-rod power-cooling-mismatch (PCM) and irradiation effects (IE) tests conducted to date in the Power Burst Facility (PBF) at the U.S. DOE Idaho National Engineering Laboratory. This work was performed for the U.S. NRC under contact to the Department of Energy. These tests are part of the NRC Fuel Behavior Program, which is designed to provide data for the development and verification of analytical fuel behavior models that are used to predict fuel response to abnormal or postulated accident conditions in commercial LWRs. The mechanical, chemical and thermal response of both previously unirradiated and previously irradiated LWR-type fuel rods tested under power-cooling-mismatch condition is discussed. A brief description of the test designs is presented. The results of the PCM thermal-hydraulic studies are summarized. Primary emphasis is placed on the behavior of the fuel and cladding during and after stable film boiling. (orig.) [de

  18. Dose rate determinations in the Portuguese Gamma Irradiation Facility: Monte Carlo simulations and measurements

    International Nuclear Information System (INIS)

    Oliveira, C.; Salgado, J.; Ferro de Carvalho, A.

    2000-01-01

    A simulation study of the Portuguese Gamma Irradiation Facility, UTR, has been carried out using the MCNP code. The work focused on the optimisation of the dose distribution inside the irradiation cell, dose calculations inside irradiated samples and dose calculations in critical points for protection purposes. Calculations were carried out at points inside and outside the irradiation cell, where different behaviour was expected (distance from the source, radiation absorption and scattering in irradiator structure and walls). The contributions from source, irradiator structure, sample material, carriers, walls, ceiling and floor to the photon spectra and air kerma at those points are reported and discussed. Air kerma measurements were also carried out using an ionisation chamber. Good agreement was found between experimental and calculated air kermas. (author)

  19. Spent fuels conditioning and irradiated nuclear fuel elements examination: the STAR facility and its abilities

    Energy Technology Data Exchange (ETDEWEB)

    Boussard, F.; Huillery, R. [CEA Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. d`Etudes des Combustibles; Averseng, J.L.; Serpantie, J.P. [Novatome Industries, 92 - Le Plessis-Robinson (France)

    1994-12-31

    This paper is a presentation of the STAR facility, a high activity laboratory located in Cadarache Nuclear Research Center (France). The purpose of the STAR facility and of the associated processes, is the treatment, cleaning and conditioning of spent fuels from Gas Cooled Reactors (GCR) and in particular of about 2300 spent GCR fuel cartridges irradiated more than 20 years ago in Electricite de France (EDF) or CEA Uranium Graphite GCR. The processes are: to separate the nuclear fuel from the clad remains, to chemically stabilize the nuclear material and to condition it in sealed canisters. An additional objective of STAR consists in non-destructive or destructive examinations and tests on PWR rods or FBR pins in the frame of fuel development programs. The paper describes the STAR facility conceptual design (safety design rules, hot cells..) and the different options corresponding to the GCR reconditioning process and to further research and development works on various fuel types. (J.S.). 3 figs.

  20. Spent fuels conditioning and irradiated nuclear fuel elements examination: the STAR facility and its abilities

    International Nuclear Information System (INIS)

    Boussard, F.; Huillery, R.

    1994-01-01

    This paper is a presentation of the STAR facility, a high activity laboratory located in Cadarache Nuclear Research Center (France). The purpose of the STAR facility and of the associated processes, is the treatment, cleaning and conditioning of spent fuels from Gas Cooled Reactors (GCR) and in particular of about 2300 spent GCR fuel cartridges irradiated more than 20 years ago in Electricite de France (EDF) or CEA Uranium Graphite GCR. The processes are: to separate the nuclear fuel from the clad remains, to chemically stabilize the nuclear material and to condition it in sealed canisters. An additional objective of STAR consists in non-destructive or destructive examinations and tests on PWR rods or FBR pins in the frame of fuel development programs. The paper describes the STAR facility conceptual design (safety design rules, hot cells..) and the different options corresponding to the GCR reconditioning process and to further research and development works on various fuel types. (J.S.). 3 figs

  1. Optimization of a fuel converter for the MERLIN materials testing facility

    International Nuclear Information System (INIS)

    Pouleur, Y.; Raedt, Ch. de; Malambu, E.; Minsart, G.; Vermunt, J.

    1998-01-01

    SCK-CEN is at the present time developing the MERLIN materials testing facility, to be placed in the pool at the BR2 high flux materials testing reactor. It aims at irradiating large amounts of steel samples that are subsequently to be analyzed in the framework of reactor vessel embrittlement research programmes. In order to fulfill the required fast neutron flux conditions, a converter made of highly enriched uranium fuel plates, has to be inserted between the reactor vessel and the samples. The converter will transform the BR2 thermal neutron outflow into the required fast neutron flux. This converter has to be optimised. (author)

  2. Evaluate of environment quality for γ irradiation facilities using fuzzy comprehensive judgment method

    International Nuclear Information System (INIS)

    Ha Yiming

    2002-01-01

    The environment quality of Jining Irradiation Centre new γ radiation facility was evaluated by fuzzy comprehensive judgment method. The result showed that the place of γ radiation facility was well and the measures of radiate shelter and environment protect were effective. The environment quality of its area was not obvious change and the result of environment evaluation was first-rate

  3. An X-Ray facility to perform irradiation tests and TID studies on electronics and detectors

    CERN Document Server

    Brundu, Davide; Cadeddu, Sandro; Wyllie, Ken; Ciambrone, Paolo

    2018-01-01

    The X-Ray irradiation system of the LHCb group, installed in Cagliari, is presented; with a particular focus on the setup configuration and dose rate calibration. The system can be used to perform Total Ionizing Dose (TID) studies for detectors, readout and front-end electronics. It was already used to test the nSYNC chip, an ASIC for the readout of the LHCb upgraded muon system.

  4. The Thermal-hydraulic Performance Test Report for the Non-instrumented Irradiation Test Rig of Annular Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan

    2008-09-15

    This report presents the results of pressure drop test, vibration test and endurance test for the non-instrumented rig using the irradiation test in HANARO of the double cooled annular fuel which were designed and fabricated by KAERI. From the out-pile thermal hydraulic tests, corresponding to the pressure drop of 200 kPa is measured to be about 9.72 kg/sec. Vibration frequency for the non-instrumented rig ranges from 5.0 to 10.7 kg/s. RMS(Root Mean Square) displacement for non-instrumented rig is less than 11.73 m, and the maximum displacement is less than 54.87m. The flow rate for endurance test were 10.5 kg/s, which was 110% of 9.72 kg/s. And the endurance test was carried out for 3 days. The test results found not to the wear and satisfied to the limits of pressure drop, flow rate, vibration and wear in the non-instrumented rig. This test was performed at the FIVPET facility.

  5. Gamma exposure rate estimation in irradiation facilities of nuclear research reactors

    International Nuclear Information System (INIS)

    Daoud, Adrian

    2009-01-01

    There are experimental situations in the nuclear field, in which dose estimations due to energy-dependent radiation fields are required. Nuclear research reactors provide such fields under normal operation or due to radioactive disintegration of fission products and structural materials activation. In such situations, it is necessary to know the exposure rate of gamma radiation the different materials under experimentation are subject to. Detectors of delayed reading are usually used for this purpose. Direct evaluation methods using portable monitors are not always possible, because in some facilities the entrance with such devices is often impracticable and also unsafe. Besides, these devices only provide information of the place where the measurement was performed, but not of temporal and spatial fluctuations the radiation fields could have. In this work a direct evaluation method was developed for the 'in-situ' gamma exposure rate for the irradiation facilities of the RA-1 reactor. This method is also applicable in any similar installation, and may be complemented by delayed evaluations without problem. On the other hand, it is well known that the residual effect of radiation modifies some properties of the organic materials used in reactors, such as density, colour, viscosity, oxidation level, among others. In such cases, a correct dosimetric evaluation enables in service estimation of material duration with preserved properties. This evaluation is for instance useful when applied to lubricating oils for the primary circuit pumps in nuclear power plants, thus minimizing waste generation. In this work the necessary elements required to estimate in-situ time and space integrated dose are also established for a gamma irradiated sample in an irradiation channel of a nuclear facility with zero neutron flux. (author)

  6. Post irradiation examination on test fuel pins for PWR

    International Nuclear Information System (INIS)

    Fogaca Filho, N.; Ambrozio Filho, F.

    1981-01-01

    Certain aspects of irradiation technology on test fuel pins for PWR, are studied. The results of post irradiation tests, performed on test fuel pins in hot cells, are presented. The results of the tests permit an evaluation of the effects of irradiation on the fuel and cladding of the pin. (Author) [pt

  7. Aircraft Test & Evaluation Facility (Hush House)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Test and Evaluation Facility (ATEF), or Hush House, is a noise-abated ground test sub-facility. The facility's controlled environment provides 24-hour...

  8. Reference equilibrium core with central flux irradiation facility for Pakistan research reactor-1

    International Nuclear Information System (INIS)

    Israr, M.; Shami, Qamar-ud-din; Pervez, S.

    1997-11-01

    In order to assess various core parameters a reference equilibrium core with Low Enriched Uranium (LEU) fuel for Pakistan Research Reactor (PARR-1) was assembled. Due to increased volume of reference core, the average neutron flux reduced as compared to the first higher power operation. To get a higher neutron flux an irradiation facility was created in centre of the reference equilibrium core where the advantage of the neutron flux peaking was taken. Various low power experiments were performed in order to evaluate control rods worth and neutron flux mapping inside the core. The neutron flux inside the central irradiation facility almost doubled. With this arrangement reactor operation time was cut down from 72 hours to 48 hours for the production of the required specific radioactivity. (author)

  9. NEW IRRADIATION RESEARCH FACILITIES AT THE ARMY NATICK LABORATORIES

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R. D.; Brynjolfsson, A.

    1963-03-15

    New facilities built by the U. S. Army for research on the preservation of food by ionizing radiation consist of a food processing and packaging facility and a radiation sources laboratory with two powerful low-energy radiation sources. One is a 1.3 million-curie Co/sup 60/ source consisting of 98 tubes each containing four doubly encapsulated Co/sup 60/ slugs. The second source is an electron linear accelerator with energy variable between 2 and 32 Mev. Research with the Co/sup 60/ source is concentrated on investigation of macroscopic and microscopic dose distribution in different materials irradiated with Co/sup 60/ gamma rays. Research with the linear accelerator is concentrated on dosimetry and photonuclear reactions. (A.G.W.)

  10. Manual for operation of the multipurpose thermalhydraulic test facility TOPFLOW (Transient Two Phase Flow Test Facility)

    International Nuclear Information System (INIS)

    Beyer, M.; Carl, H.; Schuetz, H.; Pietruske, H.; Lenk, S.

    2004-07-01

    The Forschungszentrum Rossendorf (FZR) e. V. is constructing a new large-scale test facility, TOPFLOW, for thermalhydraulic single effect tests. The acronym stands for transient two phase flow test facility. It will mainly be used for the investigation of generic and applied steady state and transient two phase flow phenomena and the development and validation of models of computational fluid dynamic (CFD) codes. The manual of the test facility must always be available for the staff in the control room and is restricted condition during operation of personnel and also reconstruction of the facility. (orig./GL)

  11. Integrity Assessment of HANARO Irradiation Capsule for Long-Term Irradiation Testing

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee Nam; Cho, Man Soon; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Yang, Tae Ho; Jun, Byung Hyuk; Kim, Myong Seop [KAERI, Daejeon (Korea, Republic of); Hong, Sang Hyun [Chungnam University, Daejeon (Korea, Republic of)

    2016-05-15

    The capsule technology was basically developed for irradiation testing under a commercial reactor operation environment. Most irradiation testing using capsules has been performed at around 300 .deg. C within four reactor operation cycles (about 100 days equivalent to 1.5 dpa (displacement for atom)) at HANARO. Based on the accumulated experience as well as the sophisticated requirements of users, HANARO has recently been required to support national R and D projects requiring much higher neutron fluence. To scope the user requirements for higher neutron irradiation fluence, several efforts using an instrumented capsule have been applied at HANARO. In this paper, the applied stresses on the capsule are estimated because the capsule was suspected to be susceptible to fatigue failure during irradiation testing. In addition, the on-going design improvements of the irradiation capsule for higher neutron irradiation fluence at HANARO are described. The applied stresses on the rod tip were analyzed using the ANSYS program. The applied stresses on the rod tip can be classified into stresses by the designed bottom spring, by the upward flowing coolant, by the capsule vibration, and by the welding residual stress. The maximal stresses due to the first three factors were estimated as 5.4 MPa, 132.9 MPa, and 161 MPa, respectively. These stresses do not exceed the known fatigue strength of stainless steels (∼300 MPa). Residual stress by welding is another possible stress and it is known to occur at up to about 300 MPa.

  12. Minutes of the workshop on bases of in-pile irradiation tests

    International Nuclear Information System (INIS)

    1997-03-01

    The Workshop on Bases of In-pile Irradiation Tests was held on January 29th and 30th, 1997 at the Ibarakiken Sangyo Kaikan in Mito, Ibaraki. The purpose is to discuss upgrading an in-pile irradiation test, promoting the utilization of the research and testing reactors and also activating the research potential of JAERI transversely. Main topics are the role and future plan of the research and testing reactors, a challenge to an advanced irradiation test, development of peripheral techniques for irradiation tests and future trends of the in-pile irradiation test in the 21st century. It was mainly pointed out that the in-pile irradiation test based on an analytical method using interpolation and extrapolation procedures met a turning point and that the upgrading of the irradiation and testing method should be indispensable for regaining the latest frontiers of an irradiation study using the research and testing reactors. The new concepts were also proposed on the irradiation correlation and modeling for the design of innovative materials. It was also recognized the key issues of the irradiation study in future should be an advanced irradiation testing method which can combine various types of irradiation field and control the irradiation conditions freely. In the next century in which large accelerator or new neutron source competes with research and testing reactors for neutron irradiation tests, themes of research using in-pile irradiation tests will be upgrading of the light water reactor, development of fusion reactor, basic research, biological and medical research, radioisotope production and semiconductors manufacturing, etc. It was also concluded the research and testing reactors will keep their main role in neutron irradiation research in future. This report briefly summarizes the content of 16 presentations and the discussion. The result of the questionnaires on the utilization of research and testing reactors to the participants is also attached. (J.P.N.)

  13. Genotoxicity test of irradiated foods

    International Nuclear Information System (INIS)

    Tanaka, Noriho

    2004-01-01

    Safety tests of radiation irradiated foods started as early as from 1967 in Japan and genotoxicity tests in the Hatano Res. Inst., from 1977. The latter is unique in the world and is reviewed in this paper. Tests included those for the initial injury of DNA, mutagenicity, chromosomal aberration and transformation with use of bacteria, cultured mammalian cells and animals (for chromosomal aberration, micronucleus formation and dominant lethality). Foods tested hitherto were onion, rice, wheat and flour, Vienna sausage, fish sausage (kamaboko), mandarian orange, potato, black pepper and red capsicum, of which extract or powder was subjected to the test. Irradiation doses and its purposes were 0.15-6 kGy γ-ray ( 60 Co) or electron beam by the accelerator (only for the orange), and suppression of germination, pesticide action or sterilization, respectively. Genotoxicity of all foods under tested conditions is shown negative. (N.I.)

  14. FiBi - A French network of facilities for irradiation in biology: The organisation of the network and the research opportunities associated

    International Nuclear Information System (INIS)

    Gaillard-Lecanu, E.; Coffigny, H.; Poncy, J.L.; Authier, N.; Verrey, B.; Bailly, I.; Baldacchino, G.; Bordy, J.M.; Carriere, M.; Leplat, J.J.; Pin, S.; Pommeret, S.; Thuret, J.Y.; Renault, J.P.; Cortella, I.; Duval, D.; Khodja, H.; Testard, I.

    2006-01-01

    The Life Science Division of the Atomic Energy Commission has developed a national network of available irradiation facilities for biological studies. One aim is to optimise the irradiation of biological samples, through a compendium of existing facilities allowing for the preserving and the irradiation of these samples in good conditions, and for providing an appropriate and reliable dosimetry. Given the high cost of the facilities and their specialization (nature and precision of irradiation on a cell scale, dose and dose rate), closeness is no longer the only criteria of choice for biologists. Development is leaning towards the implementation of irradiation platforms gathering irradiation tools associated with specific methods belonging to biology: cell culture, molecular biology and even animal care houses. The aim is to be able to offer biologists the most appropriate experimental tools, and to modify them according to the changing needs of radiobiology. This work is currently in progress and the database is still not exhaustive and shall be implemented as and when new documents are drawn up and new facilities are opened. (author)

  15. Influence of different irradiation facilities on the response of radioprotection devices

    International Nuclear Information System (INIS)

    Heeren de Oliveira, A.

    1984-05-01

    An EIC 1 extrapolation chamber, flushed with a methan based tissue equivalent gas is presented. This measuring device serves as a reference instrument to calibrate in tissue absorbed dose beta beams from different irradiation facilities; point radioactive sources, sources used with beam flattening filters, large area sources simulated by moving a point source. The source to detector distance has to be greater than 3 cm, requiring a transfer dosemeter for smaller distances. Influence of these different irradiation geometries has been studied on several radioprotection instruments (babyline, individual dosemeter, ionisation chamber), using three radionucleides: 147 Pm, 204 Tl, 90 Sr + 90 Y [fr

  16. Progress in food irradiation: Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Stegeman, H

    1982-11-01

    The Dutch contribution gives an accurate description of the gamma radio preservation facility where a great variety of types of fruit, vegetables, meat and spices were treated with radiosensitivity of bacteria and fungi as well as spores being tested. Wholesomeness studies were limited to feeding tests on pigs and mutagenity tests on Salmonella typhimurium. 12 products were given as authorized for irradiation stating irradiation effect, radiation dose and shelf-life duration.

  17. LLNL superconducting magnets test facility

    Energy Technology Data Exchange (ETDEWEB)

    Manahan, R; Martovetsky, N; Moller, J; Zbasnik, J

    1999-09-16

    The FENIX facility at Lawrence Livermore National Laboratory was upgraded and refurbished in 1996-1998 for testing CICC superconducting magnets. The FENIX facility was used for superconducting high current, short sample tests for fusion programs in the late 1980s--early 1990s. The new facility includes a 4-m diameter vacuum vessel, two refrigerators, a 40 kA, 42 V computer controlled power supply, a new switchyard with a dump resistor, a new helium distribution valve box, several sets of power leads, data acquisition system and other auxiliary systems, which provide a lot of flexibility in testing of a wide variety of superconducting magnets in a wide range of parameters. The detailed parameters and capabilities of this test facility and its systems are described in the paper.

  18. IFMIF (International Fusion Materials Irradiation Facility) key element technology phase task description

    Energy Technology Data Exchange (ETDEWEB)

    Ida, M.; Nakamura, H.; Sugimoto, M.; Yutani, T.; Takeuchi, H. [eds.] [Japan Atomic Energy Research Inst., Tokai Research Establishment, Fusion Neutron Laboratory, Tokai, Ibaraki (Japan)

    2000-08-01

    In 2000, a 3 year Key Element technology Phase (KEP) of the International Fusion Materials Irradiation Facility (IFMIF) has been initiated to reduce the key technology risk factors needed to achieve continuous wave (CW) beam with the desired current and energy and to reach the corresponding power handling capabilities in the liquid lithium target system. In the KEP, the IFMIF team (EU, Japan, Russian Federation, US) will perform required tasks. The contents of the tasks are described in the task description sheet. As the KEP tasks, the IFMIF team have proposed 27 tasks for Test Facilities, 12 tasks for Target, 26 tasks for Accelerator and 18 tasks for Design Integration. The task description by RF is not yet available. The task items and task descriptions may be added or revised with the progress of KEP activities. These task description sheets have been compiled in this report. After 3 years KEP, the results of the KEP tasks will be reviewed. Following the KEP, 3 years Engineering Validation Phase (EVP) will continue for IFMIF construction. (author)

  19. Nuclear irradiation parameters of beryllium under fusion, fission and IFMIF irradiation conditions

    International Nuclear Information System (INIS)

    Fischer, U.; Chen, Y.; Leichtle, D.; Simakov, S.; Moeslang, A.; Vladimirov, P.

    2004-01-01

    A computational analysis is presented of the nuclear irradiation parameters for Beryllium under irradiation in typical neutron environments of fission and fusion reactors, and of the presently designed intense fusion neutron source IFMIF. The analysis shows that dpa and Tritium production rates at fusion relevant levels can be achieved with existing high flux fission reactors while the achievable Helium production is too low. The resulting He-Tritium and He/dpa ratios do not meet typical fusion irradiation conditions. Irradiation simulations in the medium flux test modules of the IFMIF neutron source facility were shown to be more suitable to match fusion typical irradiation conditions. To achieve sufficiently high production rates it is suggested to remove the creep-fatigue testing machine together with the W spectra shifter plate and move the tritium release module upstream towards the high flux test module. (author)

  20. The post-irradiated examination of CANDU type fuel irradiated in the Institute for Nuclear Research TRIGA reactor

    International Nuclear Information System (INIS)

    Tuturici, I.L.; Parvan, M.; Dobrin, R.; Popov, M.; Radulescu, R.; Toma, V.

    1995-01-01

    This post-irradiation examination work has been done under the Research Contract No. 7756/RB, concluded between the International Atomic Energy Agency and the Institute for Nuclear Research. The paper contains a general description of the INR post-irradiation facility and methods and the relevant post-irradiation examination results obtained from an irradiated experimental CANDU type fuel element designed, manufactured and tested by INR in a power ramp test in the 100 kW Pressurised Water Irradiation Loop of the TRIGA 14 MW(th) Reactor. The irradiation experiment consisted in testing an assembly of six fuel elements, designed to reach a bumup of ∼ 200 MWh/kgU, with typical CANDU linear power and ramp rate. (author)

  1. Simulation for evaluation of the multi-ion-irradiation Laboratory of TechnoFusion facility and its relevance for fusion applications

    International Nuclear Information System (INIS)

    Jimenez-Rey, D.; Mota, F.; Vila, R.; Ibarra, A.; Ortiz, Christophe J.; Martinez-Albertos, J.L.; Roman, R.; Gonzalez, M.; Garcia-Cortes, I.; Perlado, J.M.

    2011-01-01

    Thermonuclear fusion requires the development of several research facilities, in addition to ITER, needed to advance the technologies for future fusion reactors. TechnoFusion will focus in some of the priority areas identified by international fusion programmes. Specifically, the TechnoFusion Area of Irradiation of Materials aims at surrogating experimentally the effects of neutron irradiation on materials using a combination of ion beams. This paper justifies this approach using computer simulations to validate the multi-ion-irradiation Laboratory. The planned irradiation facility will investigate the effects of high energetic radiations on reactor-relevant materials. In a second stage, it will also be used to analyze the performance of such materials and evaluate newly designed materials. The multi-ion-irradiation Laboratory, both triple irradiation and high-energy proton irradiation, can provide valid experimental techniques to reproduce the effect of neutron damage in fusion environment.

  2. Dismantling of Irradiation Facility Selfshielded of Investigation Model MPX- γ-25M

    International Nuclear Information System (INIS)

    Soguero, D.; Rapado, M.; Prieto, E.; Desdin, L.; Guerra, M.; Castillo, J.

    2011-01-01

    In this paper is described the dismantling a category I selfshielded gamma irradiation facility model MPX - γ - 25M. The following specific objectives were established: a) identify aspects of the insurance contract, human and technical resources b) assess the radiological situation of the process and c) analyze potential radiological extraordinary events in each step of the process, ensuring appropriate responses, based on an evaluation of process safety. The assessment of radiological events can serve as a reference for addressing the process of dismantling other similar irradiators. (Author)

  3. Comparison of fracture behavior for low-swelling ferritic and austenitic alloys irradiated in the Fast Flux Test Facility (FFTF) to 180 DPA

    International Nuclear Information System (INIS)

    Huang, F.H.

    1992-02-01

    Fracture toughness testing was conducted to investigate the radiation embrittlement of high-nickel superalloys, modified austenitic steels and ferritic steels. These materials have been experimentally proven to possess excellent resistance to void swelling after high neutron exposures. In addition to swelling resistance, post-irradiation fracture resistance is another important criterion for reactor material selection. By means of fracture mechanics techniques the fracture behavior of those highly irradiated alloys was characterized in terms of irradiation and test conditions. Precipitation-strengthened alloys failed by channel fracture with very low postirradiation ductility. The fracture toughness of titanium-modified austenitic stainless steel D9 deteriorates with increasing fluence to about 100 displacement per atom (dpa), the fluence level at which brittle fracture appears to occur. Ferritic steels such as HT9 are the most promising candidate materials for fast and fusion reactor applications. The upper-shelf fracture toughness of alloy HT9 remained adequate after irradiation to 180 dpa although its ductile- brittle transition temperature (DBTT) shift by low temperature irradiation rendered the material susceptible to brittle fracture at room temperature. Understanding the fracture characteristics under various irradiation and test conditions helps reduce the potential for brittle fracture by permitting appropriate measure to be taken

  4. Proton irradiated graphite grades for a long baseline neutrino facility experiment

    International Nuclear Information System (INIS)

    Simos, N.; Nocera, P.; Zwaska, R.; Mokhov, N.

    2017-01-01

    In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF) of the Deep Underground Neutrino Experiment (DUNE) four graphite grades were irradiated with protons in the energy range of 140–180 MeV, to peak fluence of ~6.1×10"2"0 p/cm"2 and irradiation temperatures between 120–200 °C. The test array included POCO ZXF-5Q, Toyo-Tanso IG 430, Carbone-Lorraine 2020 and SGL R7650 grades of graphite. Irradiation was performed at the Brookhaven Linear Isotope Producer. Postirradiation analyses were performed with the objective of (a) comparing their response under the postulated irradiation conditions to guide a graphite grade selection for use as a pion target and (b) understanding changes in physical and mechanical properties as well as microstructure that occurred as a result of the achieved fluence and in particular at this low-temperature regime where pion graphite targets are expected to operate. A further goal of the postirradiation evaluation was to establish a proton-neutron correlation damage on graphite that will allow for the use of a wealth of available neutron-based damage data in proton-based studies and applications. Macroscopic postirradiation analyses as well as energy dispersive x-ray diffraction of 200 KeV x rays at the NSLS synchrotron of Brookhaven National Laboratory were employed. The macroscopic analyses revealed differences in the physical and strength properties of the four grades with behavior however under proton irradiation that qualitatively agrees with that reported for graphite under neutrons for the same low temperature regime and in particular the increase of thermal expansion, strength and Young’s modulus. The proton fluence level of ~10"2"0 cm"-"2 where strength reaches a maximum before it begins to decrease at higher fluences has been identified and it agrees with neutron-induced changes. X-ray diffraction analyses of the proton irradiated graphite revealed for the first time the similarity in

  5. Proton irradiated graphite grades for a long baseline neutrino facility experiment

    Directory of Open Access Journals (Sweden)

    N. Simos

    2017-07-01

    Full Text Available In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF of the Deep Underground Neutrino Experiment (DUNE four graphite grades were irradiated with protons in the energy range of 140–180 MeV, to peak fluence of ∼6.1×10^{20}  p/cm^{2} and irradiation temperatures between 120–200 °C. The test array included POCO ZXF-5Q, Toyo-Tanso IG 430, Carbone-Lorraine 2020 and SGL R7650 grades of graphite. Irradiation was performed at the Brookhaven Linear Isotope Producer. Postirradiation analyses were performed with the objective of (a comparing their response under the postulated irradiation conditions to guide a graphite grade selection for use as a pion target and (b understanding changes in physical and mechanical properties as well as microstructure that occurred as a result of the achieved fluence and in particular at this low-temperature regime where pion graphite targets are expected to operate. A further goal of the postirradiation evaluation was to establish a proton-neutron correlation damage on graphite that will allow for the use of a wealth of available neutron-based damage data in proton-based studies and applications. Macroscopic postirradiation analyses as well as energy dispersive x-ray diffraction of 200 KeV x rays at the NSLS synchrotron of Brookhaven National Laboratory were employed. The macroscopic analyses revealed differences in the physical and strength properties of the four grades with behavior however under proton irradiation that qualitatively agrees with that reported for graphite under neutrons for the same low temperature regime and in particular the increase of thermal expansion, strength and Young’s modulus. The proton fluence level of ∼10^{20}  cm^{−2} where strength reaches a maximum before it begins to decrease at higher fluences has been identified and it agrees with neutron-induced changes. X-ray diffraction analyses of the proton irradiated graphite

  6. Proton irradiated graphite grades for a long baseline neutrino facility experiment

    Science.gov (United States)

    Simos, N.; Nocera, P.; Zhong, Z.; Zwaska, R.; Mokhov, N.; Misek, J.; Ammigan, K.; Hurh, P.; Kotsina, Z.

    2017-07-01

    In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF) of the Deep Underground Neutrino Experiment (DUNE) four graphite grades were irradiated with protons in the energy range of 140-180 MeV, to peak fluence of ˜6.1 ×1020 p /cm2 and irradiation temperatures between 120 - 200 °C . The test array included POCO ZXF-5Q, Toyo-Tanso IG 430, Carbone-Lorraine 2020 and SGL R7650 grades of graphite. Irradiation was performed at the Brookhaven Linear Isotope Producer. Postirradiation analyses were performed with the objective of (a) comparing their response under the postulated irradiation conditions to guide a graphite grade selection for use as a pion target and (b) understanding changes in physical and mechanical properties as well as microstructure that occurred as a result of the achieved fluence and in particular at this low-temperature regime where pion graphite targets are expected to operate. A further goal of the postirradiation evaluation was to establish a proton-neutron correlation damage on graphite that will allow for the use of a wealth of available neutron-based damage data in proton-based studies and applications. Macroscopic postirradiation analyses as well as energy dispersive x-ray diffraction of 200 KeV x rays at the NSLS synchrotron of Brookhaven National Laboratory were employed. The macroscopic analyses revealed differences in the physical and strength properties of the four grades with behavior however under proton irradiation that qualitatively agrees with that reported for graphite under neutrons for the same low temperature regime and in particular the increase of thermal expansion, strength and Young's modulus. The proton fluence level of ˜1020 cm-2 where strength reaches a maximum before it begins to decrease at higher fluences has been identified and it agrees with neutron-induced changes. X-ray diffraction analyses of the proton irradiated graphite revealed for the first time the similarity in

  7. Eccentric Coil Test Facility (ECTF)

    International Nuclear Information System (INIS)

    Burn, P.B.; Walstrom, P.L.; Anderson, W.C.; Marguerat, E.F.

    1975-01-01

    The conceptual design of a facility for testing superconducting coils under some conditions peculiar to tokamak systems is given. A primary element of the proposed facility is a large 25 MJ background solenoid. Discussions of the mechanical structure, the stress distribution and the thermal stability for this coil are included. The systems for controlling the facility and diagnosing test coil behavior are also described

  8. Facility for gamma irradiations of cultured cells at low dose rates: design, physical characteristics and functioning

    International Nuclear Information System (INIS)

    Esposito, Giuseppe; Anello, Pasquale; Pecchia, Ilaria; Tabocchini, Maria Antonella; Campa, Alessandro

    2016-01-01

    We describe a low dose/dose rate gamma irradiation facility (called LIBIS) for in vitro biological systems, for the exposure, inside a CO_2 cell culture incubator, of cells at a dose rate ranging from few μGy/h to some tens of mGy/h. Three different "1"3"7Cs sources are used, depending on the desired dose rate. The sample is irradiated with a gamma ray beam with a dose rate uniformity of at least 92% and a percentage of primary 662 keV photons greater than 80%. LIBIS complies with high safety standards. - Highlights: • A gamma irradiation facility for chronic exposures of cells was set up at the Istituto Superiore di Sanità. • The dose rate uniformity and the percentage of primary 662 keV photons on the sample are greater than 92% and 80%, respectively. • The GEANT4 code was used to design the facility. • Good agreement between simulation and experimental dose rate measurements has been obtained. • The facility will allow to safely investigate different issues about low dose rate effects on cultured cells.

  9. Dosimetry for Crystals Irradiation

    CERN Document Server

    Lecomte, Pierre

    2005-01-01

    Before shipment to CMS, all PbWO4 crystals produced in China are irradiated there with 60 Co , in order to insure that the induced absorption coefficient is within specifications. Acceptance tests at CERNand at ENEA also include irradiation with gamma rays from 60 Co sources. There were initially discrepancies in quoted doses and doserates as well as in induced absorption coefficients. The present work resolves the discrepancies in irradiation measurements and defines common dosimetry methods for consistency checks between irradiation facilities.

  10. Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor

    International Nuclear Information System (INIS)

    Colautti, P.; Moro, D.; Chiriotti, S.; Conte, V.; Evangelista, L.; Altieri, S.; Bortolussi, S.; Protti, N.; Postuma, I.

    2014-01-01

    A twin TEPC with electric-field guard tubes has been constructed to be used to characterize the BNCT field of the irradiation facility of LENA reactor. One of the two mini TEPC was doped with 50 ppm of 10 B in order to simulate the BNC events occurring in BNCT. By properly processing the two microdosimetric spectra, the gamma, neutron and BNC spectral components can be derived with good precision (∼6%). However, direct measurements of 10 B in some doped plastic samples, which were used for constructing the cathode walls, point out the scarce accuracy of the nominal 10 B concentration value. The influence of the Boral ® door, which closes the irradiation channel, has been measured. The gamma dose increases significantly (+51%) when the Boral ® door is closed. The crypt-cell-regeneration weighting function has been used to measure the quality, namely the RBE µ value, of the radiation field in different conditions. The measured RBE µ values are only partially consistent with the RBE values of other BNCT facilities. - Highlights: • A counter with two mini TEPCs, both equipped with electrical-field guard tubes, has been constructed. • The microdosimetric spectrum of the LENA-reactor irradiation vane has been studied. • The radiation-field quality (RBE) assessment confirms that the D n /D tot ratio is not an accurate parameter to characterize the BNCT radiation field

  11. Ouellette Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Thermal Test Facility is a joint Army/Navy state-of-the-art facility (8,100 ft2) that was designed to:Evaluate and characterize the effect of flame and thermal...

  12. Neutron-Irradiated Samples as Test Materials for MPEX

    International Nuclear Information System (INIS)

    Ellis, Ronald James; Rapp, Juergen

    2015-01-01

    Plasma Material Interaction (PMI) is a major concern in fusion reactor design and analysis. The Material-Plasma Exposure eXperiment (MPEX) will explore PMI under fusion reactor plasma conditions. Samples with accumulated displacements per atom (DPA) damage produced by fast neutron irradiations in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) will be studied in the MPEX facility. This paper presents assessments of the calculated induced radioactivity and resulting radiation dose rates of a variety of potential fusion reactor plasma-facing materials (such as tungsten). The scientific code packages MCNP and SCALE were used to simulate irradiation of the samples in HFIR including the generation and depletion of nuclides in the material and the subsequent composition, activity levels, gamma radiation fields, and resultant dose rates as a function of cooling time. A challenge of the MPEX project is to minimize the radioactive inventory in the preparation of the samples and the sample dose rates for inclusion in the MPEX facility

  13. A new apparatus at hyper irradiation research facility at the Atomic Research Center, University of Tokyo

    International Nuclear Information System (INIS)

    Shibata, Hiromi; Iwai, Takeo; Narui, Makoto; Omata, Takao

    1996-01-01

    In the hyper irradiation research facility at the Atomic Research Center, the University of Tokyo, following apparatuses were newly installed for accelerator relating apparatus on 1995 fiscal year; 1) Hyper ion microbeam analysis apparatus, 2) Fourier conversion infrared microscopy, 3) Pico second two-dimensional fluorescence measuring apparatus, 4) Femto second wave-length reversible pulse laser radiation apparatus, and others. In addition to double irradiation, pulse beam irradiation experiment and so forth characteristic in conventional hyper irradiation research apparatus, upgrading of material irradiation experiments using these new apparatuses are intended. (G.K.)

  14. A new apparatus at hyper irradiation research facility at the Atomic Research Center, University of Tokyo

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Hiromi; Iwai, Takeo; Narui, Makoto; Omata, Takao [Tokyo Univ. (Japan). Research Center for Nuclear Science and Technology

    1996-12-01

    In the hyper irradiation research facility at the Atomic Research Center, the University of Tokyo, following apparatuses were newly installed for accelerator relating apparatus on 1995 fiscal year; (1) Hyper ion microbeam analysis apparatus, (2) Fourier conversion infrared microscopy, (3) Pico second two-dimensional fluorescence measuring apparatus, (4) Femto second wave-length reversible pulse laser radiation apparatus, and others. In addition to double irradiation, pulse beam irradiation experiment and so forth characteristic in conventional hyper irradiation research apparatus, upgrading of material irradiation experiments using these new apparatuses are intended. (G.K.)

  15. Upgrades of Hanford Engineering Development Laboratory hot cell facilities

    International Nuclear Information System (INIS)

    Daubert, R.L.; DesChane, D.J.

    1987-01-01

    The Hanford Engineering Development Laboratory operates the 327 Postirradiation Testing Laboratory (PITL) and the 324 Shielded Materials Facility (SMF). These hot cell facilities provide diverse capabilities for the postirradiation examination and testing of irradiated reactor fuels and materials. The primary function of these facilities is to determine failure mechanisms and effects of irradiation on physical and mechanical properties of reactor components. The purpose of this paper is to review major equipment and facility upgrades that enhance customer satisfaction and broaden the engineering capabilities for more diversified programs. These facility and system upgrades are providing higher quality remote nondestructive and destructive examination services with increased productivity, operator comfort, and customer satisfaction

  16. Qualification program for JHR fuel elements: Irradiation of the first JHR test assembly in the BR2-Evita loop

    International Nuclear Information System (INIS)

    Anselmet, M.-C.; Lemoine, P.; Koonen, E.; Benoit, P.; Gouat, P.; Claes, W.; Geens, F.; Miras, G.; Brisson, S.

    2010-01-01

    An experimental program has been designed by CEA to qualify the behaviour of the JHR fuel under conditions representative of the reactor operating ones. This program uses the SCK.CEN facilities, irradiating JHR lead test elements in the BR2 reactor, inside its central channel which has been particularly arranged for this objective (Evita loop). As a first step in the program, a two cycle irradiation (4 weeks by cycle) started mid-July 2009 and ended mid-November (EVITA-1). After a cooling phase, this first JHR lead test element will be submitted to post-irradiation examination. The second JHR test element began its irradiation in the first quarter of 2010; its unloading is planned before the end of 2010, after 5 cycles in the BR2 reactor. The results of these two experiments are expected as input information for the Safety Authority Report. This paper presents the qualification program with the objectives assigned to each phase (irradiation, examination). A first interpretation of the irradiation data for the first element is presented, so as the information available on the progress of the following phases of the programme. (author)

  17. Needs of in-situ materials testing under neutron irradiation

    International Nuclear Information System (INIS)

    Noda, K.; Hishinuma, A.; Kiuchi, K.

    1989-01-01

    Under neutron irradiation, the component atoms of materials are displaced as primary knock-on atoms, and the energy of the primary knock-on atoms is consumed by electron excitation and nuclear collision. Elementary irradiation defects accumulate to form damage structure including voids and bubbles. In situ test under neutron irradiation is necessary for investigating into the effect of irradiation on creep behavior, the electric properties of ceramics, transport phenomena and so on. The in situ test is also important to investigate into the phenomena related to the chemical reaction with environment during irradiation. Accelerator type high energy neutron sources are preferable to fission reactors. In this paper, the needs and the research items of in situ test under neutron irradiation using a D-Li stripping type high energy neutron source on metallic and ceramic materials are described. Creep behavior is one of the most important mechanical properties, and depends strongly on irradiation environment, also it is closely related to microstructure. Irradiation affects the electric conductibity of ceramics and also their creep behavior. In this way, in situ test is necessary. (K.I.)

  18. Engine Test Facility (ETF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Air Force Arnold Engineering Development Center's Engine Test Facility (ETF) test cells are used for development and evaluation testing of propulsion systems for...

  19. MAFF sponsored research: detection tests for irradiated food

    International Nuclear Information System (INIS)

    Blackburn, C.M.; Holley, P.A.; Pryke, D.C.

    1993-01-01

    In their 1986 report on the safety and wholesomeness of irradiated food the UK Advisory Committee on Irradiated and Novel Foods (ACINF) recognised that a generally applicable test to determine if a food had been irradiated was not available. The committee considered that, although not a pre-requisite, the existence of a detection test would be a useful supplement to a control system and do much to reassure consumers; with this in mind ACINF recommended that detection methods should be kept under review. As a consequence, in 1987 the Ministry initiated a comprehensive R and D detection test programme. Over fifty papers have been published to date as a result of this programme. MAFF (Ministry Of Agriculture Fisheries and Food) has also been involved in other research associated with irradiation and food safety, some of which is described in this paper. This paper aims to give an overview of recent work funded under the food irradiation programme. Twelve projects have been supported over the last two years, ten of which involved the development of detection tests for irradiated food. A summary of these projects is presented: - Thermoluminescence; - Electron Spin Resonance; - 2-alkylcyclobutanones; -Determination Of Hydrogen; - Differential Scanning Calorimetry; - Limulus Amoebocyte Lysate; - DNA; - Pesticide Breakdown; - Neutron Irradiation; -Future Plans. (orig./vhe)

  20. Several new thermo-hydraulic test facilities in NPIC

    International Nuclear Information System (INIS)

    Ye Shurong; Sun Yufa; Ji Fuyun; Zong Guifang; Guo Zhongchuan

    1997-01-01

    Several new thermo-hydraulic test facilities are under construction in Nuclear Power Institute of Chinese (NPIC) at Chengdu. These facilities include: 1. Nuclear Power Component Comprehensive Test Facility. 2. Reactor Hydraulic Modeling Test Facility. 3. Control Rod Drive Line Hydraulic Test Facility. 4. Large Scale Thermo-Hydraulic Test Facility. The construction of these facilities will make huge progress in the research and development capability of nuclear power technology in CHINA. The author will present a brief description of the design parameters flowchart and test program of these facilities

  1. Staged deployment of the International Fusion Materials Irradiation Facility

    International Nuclear Information System (INIS)

    Takeuchi, H.; Sugimoto, M.; Nakamura, H.

    2001-01-01

    The International Fusion Materials Irradiation Facility (IFMIF) employs an accelerator based D-Li intense neutron source as defined in the 1995-96 Conceptual Design Activity (CDA) study. In 1999, IEA mandated a review of the CDA IFMIF design for cost reduction without change to its original mission. This objective was accomplished by eliminating the previously assumed possibility of potential upgrade of IFMIF beyond the user requirements. The total estimated cost was reduced from $797.2 M to $487.8 M. An option of deployment in 3 stages was also examined to reduce the initial investment and annual expenditures during construction. In this scenario, full performance is achieved gradually with each interim stage as follows. 1st Stage: 20% operation for material selection for ITER breeding blanket, 2nd Stage: 50% operation to demonstrate materials performance of a reference alloy for DEMO, 3rd Stage: full performance operation ( 2MW/m 2 at 500cm 3 ) to obtain engineering data for potential DEMO materials under irradiation up to 100-200 dpa. In summary, the new, reduced cost IFMIF design and staged deployment still satisfies the original mission. The estimated cost of the 1st Stage facility is only $303.6 M making it financially much more attractive. Currently, IFMIF Key Element Technology Phase (KEP) is underway to reduce the key technology risk factors. (author)

  2. Gamma Irradiation Facility at Sandia National Laboratories, Albuquerque, New Mexico. Final environmental assessment

    International Nuclear Information System (INIS)

    1995-11-01

    The US Department of Energy (DOE) has prepared an environmental assessment (EA) on the proposed construction and operation of a new Gamma Irradiation Facility (GIF) at Sandia National Laboratories/New Mexico (SNL/NM). This facility is needed to: enhance capabilities to assure technical excellence in nuclear weapon radiation environments testing, component development, and certification; comply with all applicable ES and H safeguards, standards, policies, and regulations; reduce personnel radiological exposure to comply with ALARA limits in accordance with DOE orders and standards; consolidate major gamma ray sources into a central, secured area; and reduce operational risks associated with operation of the GIF and LICA in their present locations. This proposed action provides for the design, construction, and operation of a new GIF located within TA V and the removal of the existing GIF and Low Intensity Cobalt Array (LICA). The proposed action includes potential demolition of the gamma shield walls and removal of equipment in the existing GIF and LICA. The shielding pool used by the existing GIF will remain as part of the ACRR facility. Transportation of the existing 60 Co sources from the existing LICA and GIF to the new facility is also included in the proposed action. Relocation of the gamma sources to the new GIF will be accomplished by similar techniques to those used to install the sources originally

  3. Development of irradiation technique with satured temperature capsule in the JMTR

    International Nuclear Information System (INIS)

    Ohtaka, Kimihiro

    1999-01-01

    The irradiation assisted stress corrosion cracking (IASCC) of in-core structural materials caused by the simultaneous effects of neutron irradiation and high temperature water environments has been pointed out as one of the major concerns not only for the light water reactors (LWRs) but also for the water-cooled fusion reactor, i.e,. ITER. The IASCC of the austenitic stainless steels or nickel base alloys has been studied for more than ten years under international efforts in the various projects for the plant life assessment and extension of LWRs. However its mechanism has not been clarified yet in spite of the extensive post-irradiation examinations. Under this situation, it is desired to perform irradiation tests under specially controlled conditions so that the effect of irradiation and high temperature water can be separately evaluated. In the Japan Materials Testing Reactor (JMTR), irradiation technique with the saturation temperature capsule (SATCAP) was developed for irradiation of the materials in the water with high, but constant, temperature and applied to study the IASCC. The capability of the SATCAP was improved by enhancing the temperature controllability to irradiate materials even in a low gamma region in the JMTR core. The performance tests of the improved SATCAP carried out in the JMTR have proven its capabilities. Based on experiences of the SATCAP, preliminary design study for the upgraded in-pile test facility are now underway in the JMTR. The test facility has a new test loop to achieve irradiate test simulated water environment of LWRs. The design, test results of the SATCAP and the design study of upgraded in-pile test facility are described in this paper

  4. Characterization of the neutron irradiation system for use in the Low-Dose-Rate Irradiation Facility at Sandia National Laboratories.

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Manuel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-08-01

    The objective of this work was to characterize the neutron irradiation system consisting of americium-241 beryllium (241AmBe) neutron sources placed in a polyethylene shielding for use at Sandia National Laboratories (SNL) Low Dose Rate Irradiation Facility (LDRIF). With a total activity of 0.3 TBq (9 Ci), the source consisted of three recycled 241AmBe sources of different activities that had been combined into a single source. The source in its polyethylene shielding will be used in neutron irradiation testing of components. The characterization of the source-shielding system was necessary to evaluate the radiation environment for future experiments. Characterization of the source was also necessary because the documentation for the three component sources and their relative alignment within the Special Form Capsule (SFC) was inadequate. The system consisting of the source and shielding was modeled using Monte Carlo N-Particle transport code (MCNP). The model was validated by benchmarking it against measurements using multiple techniques. To characterize the radiation fields over the full spatial geometry of the irradiation system, it was necessary to use a number of instruments of varying sensitivities. First, the computed photon radiography assisted in determining orientation of the component sources. With the capsule properly oriented inside the shielding, the neutron spectra were measured using a variety of techniques. A N-probe Microspec and a neutron Bubble Dosimeter Spectrometer (BDS) set were used to characterize the neutron spectra/field in several locations. In the third technique, neutron foil activation was used to ascertain the neutron spectra. A high purity germanium (HPGe) detector was used to characterize the photon spectrum. The experimentally measured spectra and the MCNP results compared well. Once the MCNP model was validated to an adequate level of confidence, parametric analyses was performed on the model to optimize for potential

  5. Application of an experimental irradiation facility type K-120 for the radiation treatment of agricultural products in large quantity

    International Nuclear Information System (INIS)

    Stenger, V.; Foeldiak, G.; Horvath, I.; Hargittai, P.; Bartfai, Cs.

    1979-01-01

    During experimental and pilot irradiation carried out by the 60 Co irradiation facility type K-120 of the Institute of Isotopes of the Hungarian Academy of Sciences an irradiation technology for the treatment of agricultural and food products of considerable density has been developed. Applying transport containers of commercial size the intermittent radiation treatment of great quantity products was made possible with homogeneous dose distribution. The radiation technical characteristics, the utilization coefficient and the capacity of the facility for every agricultural product were calculated. (author)

  6. 2 MeV, 60 kW dual-beam type electron accelerator irradiation facility

    International Nuclear Information System (INIS)

    Yotsumoto, Keiichi; Kanazawa, Takao; Haruyama, Yasuyuki; Agematsu, Takashi; Mizuhashi, Kiyoshi; Sunaga, Hiromi; Washino, Masamitsu; Tamura, Naoyuki

    1984-02-01

    The specification of new irradiation facility which has been constructed from 1978 through 1981 as the replacement of 1st Accelerator of JAERI, TRCRE are described. The accelerator is the Cockcroft-Walton type and both vertical and horizontal accelerating tubes are arranged on a single high voltage generator. Transferring of the high voltage to the horizontal accelerating tube is performed with the high voltage changing system in the pressure vessel. The output ratings of the accelerator are 2 MV of acceleration voltage and 30 mA of beam current. By providing the dual beam system, two irradiation rooms, one for vertical and the other for horizontal beam, are independently operationable. Persons can enter the horizontal irradiation room for experimental setting even when the vertical irradiation room is in operation. The specification of the buildings, the exhaust air treatment system, the irradiation conveyor and the safety observation system are also described. (author)

  7. Cryogenic test facility at VECC, Kolkata

    International Nuclear Information System (INIS)

    Sarkar, Amit; Bhunia, Uttam; Pradhan, J.; Sur, A.; Bhandari, R.K.; Ranganathan, R.

    2003-01-01

    In view of proposed K-500 superconducting cyclotron project, cryogenic test facility has been set up at the centre. The facility can broadly be categorized into two- a small scale test facility and a large scale test facility. This facility has been utilized for the calibration of liquid helium level probe, cryogenic temperature probe, and I-B plot for a 7 T superconducting magnet. Spiral-shaped superconducting short sample with specific dimension and specially designed stainless steel sample holder has already been developed for the electrical characterisation. The 1/5 th model superconducting coil along with its quench detection circuit and dump resistor has also been developed

  8. Existing and projected neutron sources and low-temperature irradiation facilities in Germany

    International Nuclear Information System (INIS)

    Boening, K.

    1984-01-01

    In this paper, a contribution given at the Kyoto University Research Reactor Institute to the temporal meeting on the design of the facilities for high flux, low temperature irradiation is summarized. The following five subjects were discussed. The project of modernizing the swimming pool type research reactor FRM with 4 MW power at Munich is to achieve relatively high thermal neutron flux, and an extremely compact core is designed. The existing low temperature irradiation facility (LTIF) of the FRM is the most powerful in the world, and has been successfully operated more than 20 years. The fast and thermal neutron fluxes are 2.9 x 10 13 and 3.5 x 10 13 /cm 2 sec, respectively. The experimental techniques in the LTIF of the FRM, such as a measuring cryostat, the mounting of irradiated samples and so on, are described. The installation of new LTIFs in connection with the projects of advanced neutron sources in Germany is likely to be made in the modernized FRM at Garching, in the spallation neutron source SNQ at KFA Juelich and so on. The interesting problems in fundamental and applied researches with LTIFs, and the unusual application of LTIFs are shown. (Kako, I.)

  9. Construction and commissioning test report of the CEDM test facility

    Energy Technology Data Exchange (ETDEWEB)

    Chung, C. H.; Kim, J. T.; Park, W. M.; Youn, Y. J.; Jun, H. G.; Choi, N. H.; Park, J. K.; Song, C. H.; Lee, S. H.; Park, J. K

    2001-02-01

    The test facility for performance verification of the control element drive mechanism (CEDM) of next generation power plant was installed at the site of KAERI. The CEDM was featured a mechanism consisting of complicated mechanical parts and electromagnetic control system. Thus, a new CEDM design should go through performance verification tests prior to it's application in a reactor. The test facility can simulate the reactor operating conditions such as temperature, pressure and water quality and is equipped with a test chamber to accomodate a CEDM as installed in the power plant. This test facility can be used for the following tests; endurance test, coil cooling test, power measurement and reactivity rod drop test. The commissioning tests for the test facility were performed up to the CEDM test conditions of 320 C and 150 bar, and required water chemistry was obtained by operating the on-line water treatment system.

  10. Construction and commissioning test report of the CEDM test facility

    International Nuclear Information System (INIS)

    Chung, C. H.; Kim, J. T.; Park, W. M.; Youn, Y. J.; Jun, H. G.; Choi, N. H.; Park, J. K.; Song, C. H.; Lee, S. H.; Park, J. K.

    2001-02-01

    The test facility for performance verification of the control element drive mechanism (CEDM) of next generation power plant was installed at the site of KAERI. The CEDM was featured a mechanism consisting of complicated mechanical parts and electromagnetic control system. Thus, a new CEDM design should go through performance verification tests prior to it's application in a reactor. The test facility can simulate the reactor operating conditions such as temperature, pressure and water quality and is equipped with a test chamber to accomodate a CEDM as installed in the power plant. This test facility can be used for the following tests; endurance test, coil cooling test, power measurement and reactivity rod drop test. The commissioning tests for the test facility were performed up to the CEDM test conditions of 320 C and 150 bar, and required water chemistry was obtained by operating the on-line water treatment system

  11. Optimization of the irradiation beam in the BNCT research facility at IEA-R1 reactor

    International Nuclear Information System (INIS)

    Castro, Vinicius Alexandre de

    2014-01-01

    Boron Neutron Capture Therapy (BNCT) is a radiotherapeutic technique for the treatment of some types of cancer whose useful energy comes from a nuclear reaction that occurs when thermal neutron impinges upon a Boron-10 atom. In Brazil there is a research facility built along the beam hole number 3 of the IEA-R1 research reactor at IPEN, which was designed to perform BNCT research experiments. For a good performance of the technique, the irradiation beam should be mostly composed of thermal neutrons with a minimum as possible gamma and above thermal neutron components. This work aims to monitor and evaluate the irradiation beam on the sample irradiation position through the use of activation detectors (activation foils) and also to propose, through simulation using the radiation transport code, MCNP, new sets of moderators and filters which shall deliver better irradiation fields at the irradiation sample position In this work, a simulation methodology, based on a MCNP card, known as wwg (weight window generation) was studied, and the neutron energy spectrum has been experimentally discriminated at 5 energy ranges by using a new set o activation foils. It also has been concluded that the BNCT research facility has the required thermal neutron flux to perform studies in the area and it has a great potential for improvement for tailoring the irradiation field. (author)

  12. Ice condenser testing facility and plans

    International Nuclear Information System (INIS)

    Kannberg, L.D.; Ross, B.A.; Eschbach, E.J.; Ligotke, M.W.

    1987-01-01

    A facility is being constructed to experimentally validate the ICEDF computer code. The code was developed to estimate the extent of fission product retention in the ice compartments of pressurized water reactor ice condenser containment systems during severe accidents. The design and construction of the facility is based on a test design that addresses the validation needs of the code for conditions typical of those expected to occur during severe pressurized water reactor accidents. Detailed facility design has followed completion of a test design (i.e., assembled test cases each involving a different set of aerosol and thermohydraulic flow conditions). The test design was developed with the aid of statistical test design software and was scrutinized for applicability with the aid of ICEDF simulations. The test facility will incorporate a small section of a prototypic ice condenser (e.g., a cross section comprising the equivalent of four 1-ft-diameter ice baskets to their full prototypic height of 48 ft). The development of the test design, the detailed facility design, and the construction progress are described in this paper

  13. The radiation field in the New Gamma Irradiation Facility GIF++ at CERN

    CERN Document Server

    Pfeiffer, Dorothea

    2017-09-11

    The high-luminosity LHC (HL-LHC) upgrade is setting now a new challenge for particle detector technologies. The increase in luminosity will produce a particle background in the gas-based muon detectors that is ten times higher than under conditions at the LHC. The detailed knowledge of the detector performance in the presence of such a high background is crucial for an optimized design and efficient operation after the HL-LHC upgrade. A precise understanding of possible aging effects of detector materials and gases is of extreme importance. To cope with these challenging requirements, a new Gamma Irradiation Facility (GIF++) was designed and built at the CERN SPS North Area as successor of the Gamma Irradiation Facility (GIF) during the Long Shutdown 1 (LS1) period. It features an intense source of 662 keV photons with adjustable intensity, to simulate continuous background over large areas, and, combined with a high energy muon beam, to measure detector performance in the presence of the background. The new ...

  14. Tensile and fracture toughness test results of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Chaouadi, R.; Moons, F.; Puzzolante, J.L. [Centre d`Etude de l`Energie Nucleaire, Mol (Belgium)

    1998-01-01

    Tensile and fracture toughness test results of four Beryllium grades are reported here. The flow and fracture properties are investigated by using small size tensile and round compact tension specimens. Irradiation was performed at the BR2 material testing reactor which allows various temperature and irradiation conditions. The fast neutron fluence (>1 MeV) ranges between 0.65 and 2.45 10{sup 21} n/cm{sup 2}. In the meantime, un-irradiated specimens were aged at the irradiation temperatures to separate if any the effect of temperature from irradiation damage. Test results are analyzed and discussed, in particular in terms of the effects of material grade, test temperature, thermal ageing and neutron irradiation. (author)

  15. Mark 1 Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Mark I Test Facility is a state-of-the-art space environment simulation test chamber for full-scale space systems testing. A $1.5M dollar upgrade in fiscal year...

  16. Pavement Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Comprehensive Environmental and Structural AnalysesThe ERDC Pavement Testing Facility, located on the ERDC Vicksburg campus, was originally constructed to provide an...

  17. Food irradiation: technology transfer to developing countries

    International Nuclear Information System (INIS)

    Kunstadt, Peter

    1990-01-01

    This paper discusses Nordion's experiences to-date with the Food Irradiation Project in Thailand (1987-1990). This project will enable the Government of Thailand and the Thai food industry to benefit from established Canadian technology in food irradiation. It includes the design and the construction in Thailand of a multipurpose irradiation facility, similar to the Canadian Irradiation Centre. In addition Canada provides the services, for extended periods of time, of construction and installation management and experts in facility operation, maintenance and training. The Technology Transfer component is a major part of the overall Thai Food Irradiation Project. Its purpose is to familiarize Thai government and industry personnel with Canadian requirements in food regulations and distribution and to conduct market and consumer tests of selected Thai irradiated food products in Canada, once the products have Canadian regulatory approval. On completion of this project, Thailand will have the necessary facility, equipment and training to continue to provide leadership in food irradiation research, as well as scientific and technical support to food industries not only in Thailand but also in the ASEAN region. (author)

  18. Food irradiation: Technology transfer to developing countries

    Science.gov (United States)

    Kunstadt, Peter

    This paper discusses Nordion's experiences to-date with the Food Irradiation Project in Thailand (1987-1990). This project will enable the Government of Thailand and the Thai food industry to benefit from established Canadian technology in food irradiation. It includes the design and the construction in Thailand of a multipurpose irradiation facility, similar to the Canadian Irradiation Centre. In addition Canada provides the services, for extended periods of time, of construction and installation management and experts in facility operation, maintenance and training. The Technology Transfer component is a major part of the overall Thai Food Irradiation Project. Its purpose is to familiarize Thai government and industry personnel with Canadian requirements in food regulations and distribution and to conduct market and consumer tests of selected Thai irradiated food products in Canada, once the products have Canadian regulatory approval. On completion of this project, Thailand will have the necessary facility, equipment and training to continue to provide leadership in food irradiation research, as well as scientific and technical support to food industries not only in Thailand by also in the ASEAN region.

  19. Food irradiation: technology transfer to developing countries

    Energy Technology Data Exchange (ETDEWEB)

    Kunstadt, Peter [Nordion International Inc., Kanata, ON (Canada)

    1990-01-01

    This paper discusses Nordion's experiences to-date with the Food Irradiation Project in Thailand (1987-1990). This project will enable the Government of Thailand and the Thai food industry to benefit from established Canadian technology in food irradiation. It includes the design and the construction in Thailand of a multipurpose irradiation facility, similar to the Canadian Irradiation Centre. In addition Canada provides the services, for extended periods of time, of construction and installation management and experts in facility operation, maintenance and training. The Technology Transfer component is a major part of the overall Thai Food Irradiation Project. Its purpose is to familiarize Thai government and industry personnel with Canadian requirements in food regulations and distribution and to conduct market and consumer tests of selected Thai irradiated food products in Canada, once the products have Canadian regulatory approval. On completion of this project, Thailand will have the necessary facility, equipment and training to continue to provide leadership in food irradiation research, as well as scientific and technical support to food industries not only in Thailand but also in the ASEAN region. (author).

  20. Germination test for identification of gamma-irradiated bean seeds

    International Nuclear Information System (INIS)

    Wesolowska, B.; Ignatowicz, S.

    1993-01-01

    The feasibility of germination test for the practical detection of irradiated beans has not been investigated. The objective of this study was to determine if the relationship between the root growth rate and radiation dose could be used to produce a rapid analytical method for identification of irradiated beans. Such detection method could be potentially used for both (a) identification of irradiated food, and (b) for quarantine inspection (to certify that the agricultural product has been irradiated, and the pests present in it do not pose a quarantine risk). Results presented in this paper indicate that the germination test is not always capable of discriminating satisfactorily between irradiated and unirradiated samples of bean seeds, because the sensitivity of the test is often higher than the low doses which are suggested for disinfestation purposes. However, using the germination test, an unexperienced person can easily discriminate untreated bean seeds from those irradiated with 0.3-1.5 kGy doses of gamma radiation. (orig./vhe)

  1. A simple irradiation facility for radiobiological experiments with low energy protons from a cyclotron

    International Nuclear Information System (INIS)

    Mukherjee, B.

    1982-01-01

    An experimental facility for irradiation of small biological targets with low-energy protons has been developed. The depth-dose distribution in soft-tissue is calculated from the proton energy spectrum. (orig.)

  2. Evaluation of fuel rods behavior - under irradiation test

    International Nuclear Information System (INIS)

    Lameiras, F.S.; Terra, J.L.; Pinto, L.C.M.; Dias, M.S.; Pinheiro, R.B.

    1981-04-01

    By the accompanying of the irradiation of instrumented test fuel rods simulating the operational conditions in reactors, plus the results of post - irradiation exams, tests, evaluation and calibration of analitic modelling of such fuel rods is done. (E.G.) [pt

  3. Hot Hydrogen Test Facility

    International Nuclear Information System (INIS)

    W. David Swank

    2007-01-01

    The core in a nuclear thermal rocket will operate at high temperatures and in hydrogen. One of the important parameters in evaluating the performance of a nuclear thermal rocket is specific impulse, ISp. This quantity is proportional to the square root of the propellant's absolute temperature and inversely proportional to square root of its molecular weight. Therefore, high temperature hydrogen is a favored propellant of nuclear thermal rocket designers. Previous work has shown that one of the life-limiting phenomena for thermal rocket nuclear cores is mass loss of fuel to flowing hydrogen at high temperatures. The hot hydrogen test facility located at the Idaho National Lab (INL) is designed to test suitability of different core materials in 2500 C hydrogen flowing at 1500 liters per minute. The facility is intended to test non-uranium containing materials and therefore is particularly suited for testing potential cladding and coating materials. In this first installment the facility is described. Automated Data acquisition, flow and temperature control, vessel compatibility with various core geometries and overall capabilities are discussed

  4. Textiles Performance Testing Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Textiles Performance Testing Facilities has the capabilities to perform all physical wet and dry performance testing, and visual and instrumental color analysis...

  5. Some general requirements for irradiation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Myers, H P; Skjoeldebrand, R

    1960-05-15

    This paper is limited to the interests of the EAES-symposium, namely the use of reactors for materials research and testing, for convenience we exclude consideration of chemical effects and problems of coolant technology. Its purpose is to try to define the general requirements for irradiation experiments and the reactors housing them; to see what facilities for irradiation experiments are available within the European Atomic Energy Society countries and finally, to point out possible limitations of these facilities.

  6. Stress corrosion testing of irradiated cladding tubes

    International Nuclear Information System (INIS)

    Lunde, L.; Olshausen, K.D.

    1980-01-01

    Samples from two fuel rods with different cladding have been stress corrosion tested by closed-end argon-iodine pressurization at 320 0 C. The fuel rods with stress relieved and recrystallized Zircaloy-2 had received burnups of 10.000 and 20.000 MWd/ton UO 2 , respectively. It was found that the SCC failure stress was unchanged or slightly higher for the irradiated than for the unirradiated control tubes. The tubes failed consistently in the end with the lowest irradiation dose. The diameter increase of the irradiated cladding during the test was 1.1% for the stress-relieved samples and 0.24% for the recrystallized samples. SEM examination revealed no major differences between irradiated and unirradiated cladding. A ''semi-ductile'' fracture zone in recrystallized material is described in some detail. (author)

  7. New Sensors for In-Pile Temperature Detection at the Advanced Test Reactor National Scientific User Facility

    International Nuclear Information System (INIS)

    Rempe, J.L.; Knudson, D.L.; Daw, J.E.; Condie, K.G.; Wilkins, S. Curtis

    2009-01-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. As a user facility, the ATR is supporting new users from universities, laboratories, and industry, as they conduct basic and applied nuclear research and development to advance the nation's energy security needs. A key component of the ATR NSUF effort is to develop and evaluate new in-pile instrumentation techniques that are capable of providing measurements of key parameters during irradiation. This paper describes the strategy for determining what instrumentation is needed and the program for developing new or enhanced sensors that can address these needs. Accomplishments from this program are illustrated by describing new sensors now available and under development for in-pile detection of temperature at various irradiation locations in the ATR.

  8. Irradiation test and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S.

    2002-05-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  9. Design and construction of the Fuels and Materials Examination Facility

    International Nuclear Information System (INIS)

    Burgess, C.A.

    1979-01-01

    Final design is more than 85 percent complete on the Fuels and Materials Examination Facility, the facility for post-irradiation examination of the fuels and materials tests irradiated in the FFTF and for fuel process development, experimental test pin fabrication and supporting storage, assay, and analytical chemistry functions. The overall facility is generally described with specific information given on some of the design features. Construction has been initiated and more than 10% of the construction contracts have been awarded on a fixed price basis

  10. The proposed cold neutron irradiation facility at the Breazeale reactor

    International Nuclear Information System (INIS)

    Dimeo, R. M.; Sokol, P. E.; Carpenter, J. M.

    1997-01-01

    We discuss the design considerations of a Cold Neutron Irradiation Facility (CNIF) originally to have been installed at the Penn State Breazeale Reactor (PSBR). The goal of this project was to study the effects of radiation-induced damage to cryogenic moderators and, in particular, solid methane. This work evolved through the design stage undergoing a full safety analysis and received tentative approval from the PSBR Safeguards Committee but was discontinued due to budgetary constraints. (auth)

  11. IFMIF, a fusion relevant neutron source for material irradiation current status

    International Nuclear Information System (INIS)

    Knaster, J.; Chel, S.; Fischer, U.; Groeschel, F.; Heidinger, R.; Ibarra, A.; Micciche, G.; Möslang, A.; Sugimoto, M.; Wakai, E.

    2014-01-01

    The d-Li based International Fusion Materials Irradiation Facility (IFMIF) will provide a high neutron intensity neutron source with a suitable neutron spectrum to fulfil the requirements for testing and qualifying fusion materials under fusion reactor relevant irradiation conditions. The IFMIF project, presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase under the Broader Approach (BA) Agreement between Japan Government and EURATOM, aims at the construction and testing of the most challenging facility sub-systems, such as the first accelerator stage, the Li target and loop, and irradiation test modules, as well as the design of the entire facility, thus to be ready for the IFMIF construction with a clear understanding of schedule and cost at the termination of the BA mid-2017. The paper reviews the IFMIF facility and its principles, and reports on the status of the EVEDA activities and achievements

  12. Assessment of gold flux monitor at irradiation facilities of MINT TRIGA MK II reactor

    International Nuclear Information System (INIS)

    Wee Boon Siong; Abdul Khalik Wood; Mohd Suhaimi Hamzah; Shamsiah Abdul Rahman; Md Suhaimi Elias; Nazaratul Ashifa Abd Salim

    2005-01-01

    Neutron source of MINTs TRIGA MK II reactor has been used for activation analysis for many years and neutron flux plays important role in activation of samples at various positions. Currently, two irradiation facilities namely the pneumatic transfer system and rotary rack are available to cater for short and long lived irradiation. Neutron flux variation for both irradiation facilities have been determined using gold wire and gold solution as flux monitor. However, the use of gold wire as flux monitor is costlier if compared to gold solution. The results from analysis of certified reference materials showed that gold solution as flux monitors yield satisfactory results and proved to safe cost on the purchasing of gold wire. Further experiment on self-shielding effects of gold solution at various concentrations has been carried out. This study is crucial in providing vital information on the suitable concentration for gold solution as flux monitor. In the near future, gold solution flux monitor will be applied for routine analysis and hence to improve the capability of the laboratory on neutron activation analysis. (Author)

  13. In situ ion irradiation/implantation studies in the HVEM-Tandem Facility at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Allen, C.W.; Funk, L.L.; Ryan, E.A.; Taylor, A.

    1988-09-01

    The HVEM-Tandem User Facility at Argonne National Laboratory interfaces two ion accelerators, a 2 MV tandem accelerator and a 650 kV ion implanter, to a 1.2 MV high voltage electron microscope. This combination allows experiments involving simultaneous ion irradiation/ion implantation, electron irradiation and electron microscopy/electron diffraction to be performed. In addition the availability of a variety of microscope sample holders permits these as well as other types of in situ experiments to be performed at temperatures ranging from 10-1300 K, with the sample in a stressed state or with simultaneous determination of electrical resistivity of the specimen. This paper summarizes the details of the Facility which are relevant to simultaneous ion beam material modification and electron microscopy, presents several current applications and briefly describes the straightforward mechanism for potential users to access this US Department of Energy supported facility. 7 refs., 1 fig., 1 tab

  14. Millimeter-wave Instrumentation Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Millimeter-wave Instrumentation Test Facility conducts basic research in propagation phenomena, remote sensing, and target signatures. The facility has a breadth...

  15. Ground test facility for nuclear testing of space reactor subsystems

    International Nuclear Information System (INIS)

    Quapp, W.J.; Watts, K.D.

    1985-01-01

    Two major reactor facilities at the INEL have been identified as easily adaptable for supporting the nuclear testing of the SP-100 reactor subsystem. They are the Engineering Test Reactor (ETR) and the Loss of Fluid Test Reactor (LOFT). In addition, there are machine shops, analytical laboratories, hot cells, and the supporting services (fire protection, safety, security, medical, waste management, etc.) necessary to conducting a nuclear test program. This paper presents the conceptual approach for modifying these reactor facilities for the ground engineering test facility for the SP-100 nuclear subsystem. 4 figs

  16. Environmental Test Facility (ETF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Environmental Test Facility (ETF) provides non-isolated shock testing for stand-alone equipment and full size cabinets under MIL-S-901D specifications. The ETF...

  17. Current status of JAERI Tokai hot cell facilities

    International Nuclear Information System (INIS)

    Itami, Hiroharu; Morozumi, Minoru; Yamahara, Takeshi

    1992-01-01

    JAERI has 4 hot cell facilities in order to examine high radioactive materials. Three of them, the Research Hot Laboratory, the Reactor Fuel Examination Facility and the Waste Safety Testing Facility are located in the JAERI Tokai site, and the rest is the JMTR Hot Laboratory in the Oarai site. The Research Hot Laboratory (RHL) was constructed for post-irradiation examination (PIE), especially nuclear related basic research experiment, such as metallurgical, chemical and mechanical examination on fuels and materials irradiated in research and test reactors. This facility has 10 large dimension concrete and 38 lead cells. At present the RHL is used for various kinds of examinations of high radioactive samples such as fuels of research and test reactors, power reactors and high temperature testing reactor (HTTR), and structural materials. The Reactor Fuel Examination Facility (RFEF) was designed and constructed for carrying out PIE of irradiated full-size fuel assemblies of light water reactors (LWRs). This facility has a storage pool, 8 concrete and 5 lead cells. They are currently used for safety evaluation on high burnup and advanced lWR fuels as part of the national program. The Waste Safety Testing Facility (WASTEF) was designed and constructed for safety research on long-term storage and disposal of high level radioactive wastes, generated by fuel reprocessing. The WASTEF has 5 concrete cells and 1 lead cell. Examinations on the behavior of various long-lived fission products in a glass form and in a canister and, releasing behavior of them out of a canister are carrying out under the condition at storage. (author)

  18. Economic study for the establishment of A food irradiation facility at port said harbour

    International Nuclear Information System (INIS)

    EL-Gameel, E.A.

    2004-01-01

    The present study discusses the economic aspects of establishing food irradiation facility at Port Said harbour and the effect of various parameters on the unit processing costs. The study is concerned with carrying out an economic evaluation for the application of food exports from Port Said harbour and the marketing and technical aspects where the suitable commodity mix has been determined for the agricultural crops which were proposed for irradiation. The investment criteria utilized for commercial evaluation were internal rate of return (IRR) and pay back period (PEP). The irradiation cost and the additional income are also discussed. The results of this analysis showed that the establishment of food irradiation unit in Port Said harbour in Egypt would be economically feasible

  19. Characterization of the irradiation facilities SINCA and SIRCA of the TRIGA Mark III reactor using the code MCNPX

    International Nuclear Information System (INIS)

    Delfin L, A.; Garcia M, T.; Lucatero, M. A.; Cruz G, H. S.; Gonzalez, J. A.; Vargas E, S.

    2011-11-01

    The commitment of changing fuels of high enrichment for fuels of low enrichment in the TRIGA Mark III reactor of the Nuclear Center of Mexico generates the necessity to know the distribution of the spectrum of the neutrons flux in the irradiation facilities like they are: the Pneumatic System of Capsules Irradiation and the Rotational System of Capsules Irradiation. Is very important for the experiments design as well as for the reactor safety to know the profiles of the neutrons flux and the spectrum that these maintain with the mixed core with which operates, to effect of conserving the same characteristics when the reactor core will be operated with fuel of low enrichment totally. Also, knowing the profiles of the neutrons flux, the reactor operators can optimize the irradiation conditions of the processed samples and likewise the users can select the irradiation positions more adaptable to their necessities. This work present the characterization of the neutron flux in the irradiation facilities SINCA and SIFCA, calculated with the code MCNPX. (Author)

  20. 40 CFR 792.31 - Testing facility management.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Testing facility management. 792.31... facility management. For each study, testing facility management shall: (a) Designate a study director as... appropriately tested for identity, strength, purity, stability, and uniformity, as applicable. (e) Assure that...

  1. FFTF utilization for irradiation testing

    International Nuclear Information System (INIS)

    Corrigan, D.C.; Julyk, L.J.; Hoth, C.W.; McGuire, J.C.; Sloan, W.R.

    1980-01-01

    FFTF utilization for irradiation testing is beginning. Two Fuels Open Test Assemblies and one Vibration Open Test Assembly, both containing in-core contact instrumentation, are installed in the reactor. These assemblies will be used to confirm plant design performance predictions. Some 100 additional experiments are currently planned to follow these three. This will result in an average core loading of about 50 test assemblies throughout the early FFTF operating cycles

  2. Dosimetry. Standard practice for dosimetry in gamma irradiation facilities for food and non-food processing

    International Nuclear Information System (INIS)

    2008-01-01

    This Ghana Standard outlines the installation qualification program for an irradiator and the dosimetry procedures to be followed during operational qualification, performance qualification and routine processing in facilities that process food and non-food with gamma rays. This is to ensure that the product has been treated with predetermined range of absorbed dose. It is not intended for use in X-ray and electron beam facilities and therefore dosimetry systems in such facilities are not covered

  3. 40 CFR 160.31 - Testing facility management.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Testing facility management. 160.31... GOOD LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.31 Testing facility management. For each study, testing facility management shall: (a) Designate a study director as described in § 160.33...

  4. Material testing facilities and programs for plasma-facing component testing

    Science.gov (United States)

    Linsmeier, Ch.; Unterberg, B.; Coenen, J. W.; Doerner, R. P.; Greuner, H.; Kreter, A.; Linke, J.; Maier, H.

    2017-09-01

    Component development for operation in a large-scale fusion device requires thorough testing and qualification for the intended operational conditions. In particular environments are necessary which are comparable to the real operation conditions, allowing at the same time for in situ/in vacuo diagnostics and flexible operation, even beyond design limits during the testing. Various electron and neutral particle devices provide the capabilities for high heat load tests, suited for material samples and components from lab-scale dimensions up to full-size parts, containing toxic materials like beryllium, and being activated by neutron irradiation. To simulate the conditions specific to a fusion plasma both at the first wall and in the divertor of fusion devices, linear plasma devices allow for a test of erosion and hydrogen isotope recycling behavior under well-defined and controlled conditions. Finally, the complex conditions in a fusion device (including the effects caused by magnetic fields) are exploited for component and material tests by exposing test mock-ups or material samples to a fusion plasma by manipulator systems. They allow for easy exchange of test pieces in a tokamak or stellarator device, without opening the vessel. Such a chain of test devices and qualification procedures is required for the development of plasma-facing components which then can be successfully operated in future fusion power devices. The various available as well as newly planned devices and test stands, together with their specific capabilities, are presented in this manuscript. Results from experimental programs on test facilities illustrate their significance for the qualification of plasma-facing materials and components. An extended set of references provides access to the current status of material and component testing capabilities in the international fusion programs.

  5. Study on the improvement of irradiation process

    International Nuclear Information System (INIS)

    Jin, Joon Ha; Yoon, Byung Mok; Kim, Ki Yup; Nho, Young Chang; Lee, Young Keun; Park, Soon Chul; Na, Bong Joo; Yoo, Young Soo

    1993-02-01

    The source operation system, carrier systems, safety systems and all other miscellaneous systems were installed for the High Intensity Co-60 Gamma Irradiation Facility. The Co-60 Source(72,800 Ci) was installed on the source rack by Canadian engineers and the facility was approved to be safe after some test operations. The acceleration tube, transformer, main control panel and high voltage cable were installed in the Electron Accelerator Facility. All parts of the accelerator were inspected and repaired. The Low Intensity Co-60 Gamma Irradiator in Seoul was dismantled for moving to Taejon and source operation and safety systems were prepared for the new facility. During the installations, old parts and equipments of each irradiation facility were replaced and many improvement were made on the systems by installing the irradiation tables and experimental holes, movements of control and machine room and ventilation fans to each reasonable position, and installation of additional fire alarm system and cable terminal box. The knowledge and experiences obtained during the installations will be very helpful for the operation and maintenance of the facilities in the future. The facilities will be utilized for the various researches and application fields such as polymer, food agriculture, biology, equipment qualification, etc. (Author)

  6. The RaDIATE High-Energy Proton Materials Irradiation Experiment at the Brookhaven Linac Isotope Producer Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ammigan, Kavin; et al.

    2017-05-01

    The RaDIATE collaboration (Radiation Damage In Accelerator Target Environments) was founded in 2012 to bring together the high-energy accelerator target and nuclear materials communities to address the challenging issue of radiation damage effects in beam-intercepting materials. Success of current and future high intensity accelerator target facilities requires a fundamental understanding of these effects including measurement of materials property data. Toward this goal, the RaDIATE collaboration organized and carried out a materials irradiation run at the Brookhaven Linac Isotope Producer facility (BLIP). The experiment utilized a 181 MeV proton beam to irradiate several capsules, each containing many candidate material samples for various accelerator components. Materials included various grades/alloys of beryllium, graphite, silicon, iridium, titanium, TZM, CuCrZr, and aluminum. Attainable peak damage from an 8-week irradiation run ranges from 0.03 DPA (Be) to 7 DPA (Ir). Helium production is expected to range from 5 appm/DPA (Ir) to 3,000 appm/DPA (Be). The motivation, experimental parameters, as well as the post-irradiation examination plans of this experiment are described.

  7. The Testing Behind The Test Facility: The Acoustic Design of the NASA Glenn Research Center's World-Class Reverberant Acoustic Test Facility

    Science.gov (United States)

    Hozman, Aron D.; Hughes, William O.; McNelis, Mark E.; McNelis, Anne M.

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is leading the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC's Plum Brook Station in Sandusky, Ohio, USA. Benham Companies, LLC is currently constructing modal, base-shake sine and reverberant acoustic test facilities to support the future testing needs of NASA's space exploration program. The large Reverberant Acoustic Test Facility (RATF) will be approximately 101,000 cu ft in volume and capable of achieving an empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world's known active reverberant acoustic test facilities. The key to achieving the expected acoustic test spectra for a range of many NASA space flight environments in the RATF is the knowledge gained from a series of ground acoustic tests. Data was obtained from several NASA-sponsored test programs, including testing performed at the National Research Council of Canada's acoustic test facility in Ottawa, Ontario, Canada, and at the Redstone Technical Test Center acoustic test facility in Huntsville, Alabama, USA. The majority of these tests were performed to characterize the acoustic performance of the modulators (noise generators) and representative horns that would be required to meet the desired spectra, as well as to evaluate possible supplemental gas jet noise sources. The knowledge obtained in each of these test programs enabled the design of the RATF sound generation system to confidently advance to its final acoustic design and subsequent on-going construction.

  8. AGR-2 Irradiation Test Final As-Run Report

    Energy Technology Data Exchange (ETDEWEB)

    Collin, Blaise P. [Idaho National Lab. (INL), Idaho Falls, ID (United States). VHTR Program

    2014-08-01

    This document presents the as-run analysis of the AGR-2 irradiation experiment. AGR-2 is the second of the planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the U.S. Department of Energy as part of the Very High Temperature Reactor (VHTR) Technology Development Office (TDO) program. The objectives of the AGR-2 experiment are to: 1. Irradiate UCO (uranium oxycarbide) and UO2 (uranium dioxide) fuel produced in a large coater. Fuel attributes are based on results obtained from the AGR-1 test and other project activities. 2. Provide irradiated fuel samples for post-irradiation experiment (PIE) and safety testing. 3. Support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. The primary objective of the test was to irradiate both UCO and UO2 TRISO (tristructural isotropic) fuel produced from prototypic scale equipment to obtain normal operation and accident condition fuel performance data. The UCO compacts were subjected to a range of burnups and temperatures typical of anticipated prismatic reactor service conditions in three capsules. The test train also includes compacts containing UO2 particles produced independently by the United States, South Africa, and France in three separate capsules. The range of burnups and temperatures in these capsules were typical of anticipated pebble bed reactor service conditions. The results discussed in this report pertain only to U.S.-produced fuel.

  9. AGR-2 Irradiation Test Final As-Run Report

    Energy Technology Data Exchange (ETDEWEB)

    Collin, Blaise P. [Idaho National Lab. (INL), Idaho Falls, ID (United States). VHTR Program

    2014-08-01

    This document presents the as-run analysis of the AGR-2 irradiation experiment. AGR-2 is the second of the planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the U.S. Department of Energy as part of the Very High Temperature Reactor (VHTR) Technical Development Office (TDO) program. The objectives of the AGR-2 experiment are to: (a) Irradiate UCO (uranium oxycarbide) and UO2 (uranium dioxide) fuel produced in a large coater. Fuel attributes are based on results obtained from the AGR-1 test and other project activities. (b) Provide irradiated fuel samples for post-irradiation experiment (PIE) and safety testing. (c) Support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. The primary objective of the test was to irradiate both UCO and UO2 TRISO (tri-structural isotropic) fuel produced from prototypic scale equipment to obtain normal operation and accident condition fuel performance data. The UCO compacts were subjected to a range of burnups and temperatures typical of anticipated prismatic reactor service conditions in three capsules. The test train also includes compacts containing UO2 particles produced independently by the United States, South Africa, and France in three separate capsules. The range of burnups and temperatures in these capsules were typical of anticipated pebble bed reactor service conditions. The results discussed in this report pertain only to U.S. produced fuel.

  10. Irradiation testing of high density uranium alloy dispersion fuels

    International Nuclear Information System (INIS)

    Hayes, S.L.; Trybus, C.L.; Meyer, M.K.

    1997-10-01

    Two irradiation test vehicles have been designed, fabricated, and inserted into the Advanced Test Reactor in Idaho. Irradiation of these experiments began in August 1997. These irradiation tests were designed to obtain irradiation performance information on a variety of potential new, high-density dispersion fuels. Each of the two irradiation vehicles contains 32 microplates. Each microplate is aluminum clad, having an aluminum matrix phase and containing one of the following compositions as the fuel phase: U-10Mo, U-8Mo, U-6Mo, U-4Mo, U-9Nb-3Zr, U-6Nb-4Zr, U-5Nb-3Zr, U-6Mo-1Pt, U-6Mo-0.6Ru, U-10Mo-0.05Sn, U 2 Mo, or U 3 Si 2 . These experiments will be discharged at peak fuel burnups of 40% and 80%. Of particular interest is the fission gas retention/swelling characteristics of these new fuel alloys. This paper presents the design of the irradiation vehicles and the irradiation conditions

  11. Proton and Neutron Irradiation Tests of Readout Electronics of the ATLAS Hadronic Endcap Calorimeter

    CERN Document Server

    Menke, Sven; The ATLAS collaboration

    2012-01-01

    The readout electronics of the ATLAS Hadronic Endcap Calorimeter will have to withstand the about ten times larger radiation environment of the future high-luminosity LHC (HL-LHC) compared to their design values. The GaAs ASIC which comprises the heart of the readout electronics has been exposed to neutron and proton radiation with fluences up to ten times the total expected fluences for ten years of running of the HL-LHC. Neutron tests where performed at the NPI in Rez, Czech Republic, where a 36 MeV proton beam is directed on a thick heavy water target to produce neutrons. The proton irradiation was done with 200 MeV protons at the PROSCAN area of the Proton Irradiation Facility at the PSI in Villigen, Switzerland. In-situ measurements of S-parameters in both tests allow the evaluation of frequency dependent performance parameters - like gain and input impedance - as a function of the fluence. The linearity of the ASIC response has been measured directly in the neutron tests with a triangular input pulse of...

  12. Proton and Neutron Irradiation Tests of Readout Electronics of the ATLAS Hadronic Endcap Calorimeter

    CERN Document Server

    INSPIRE-00106910

    2012-01-01

    The readout electronics of the ATLAS Hadronic Endcap Calorimeter will have to withstand the about ten times larger radiation environment of the future high-luminosity LHC (HL-LHC) compared to their design values. The GaAs ASIC which comprises the heart of the readout electronics has been exposed to neutron and proton radiation with fluences up to ten times the total expected fluences for ten years of running of the HL-LHC. Neutron tests were performed at the NPI in Rez, Czech Republic, where a 36 MeV proton beam is directed on a thick heavy water target to produce neutrons. The proton irradiation was done with 200 MeV protons at the PROSCAN area of the Proton Irradiation Facility at the PSI in Villigen, Switzerland. In-situ measurements of S-parameters in both tests allow the evaluation of frequency dependent performance parameters - like gain and input impedance - as a function of the fluence. The linearity of the ASIC response has been measured directly in the neutron tests with a triangular input pulse of ...

  13. Irradiation test of borosilicate glass burnable poison

    International Nuclear Information System (INIS)

    Feng Mingquan; Liao Zumin; Yang Mingjin; Lu Changlong; Huang Deyang; Zeng Wangchun; Zhao Xihou

    1991-08-01

    The irradiation test and post-irradiation examinations for borosilicate glass burnable poison are introduced. Examinations include visual examination, measurement of dimensions and density, and determination of He gas releasing and 10 B burnup. The corrosion and phenomenon of irradiation densification are also discussed. Two type glass samples have been irradiated with different levels of neutron flux. It proved that the GG-17 borosilicate glass can be used as burnable poison to replace the 10 B stainless steel in the Qinshan Nuclear Power Plant, and it is safe, economical and reasonable

  14. Non-destructive test for irradiated fuels using X-ray CT system in hot-laboratory

    International Nuclear Information System (INIS)

    Kim, Heemoon; Kim, Gil-Soo; Yoo, Boung-Ok; Tahk, Young-Wook; Cho, Moon-Sung; Ahn, Sang-Bok

    2015-01-01

    To inspect inside of irradiated fuel rod for PIE in hotcell, neutron beam and X-ray have been used. Many hot laboratories in the world have shown the results for NDT by 2-D film data. Currently, computed image processing technology instead of film has been developed and CT was applied to the X-ray and neutron beam system. In this trend, our facility needed to set up X-ray system for irradiated fuel inspection and installed in hotcell with consideration of radiation damage. In this study, X-ray system was tested to be operated with radioactive samples and was performed to inspect fuel rods and observe internal damage and dimensional change. 450kV X-ray CT system was installed in hotcell with modification and tested to check image resolution and radiation damage. The image data were analyzed by 3-D computer software. 8 fuel plates and VHTR rods were inspected and measured internal shape and dimension

  15. Test facility TIMO for testing the ITER model cryopump

    International Nuclear Information System (INIS)

    Haas, H.; Day, C.; Mack, A.; Methe, S.; Boissin, J.C.; Schummer, P.; Murdoch, D.K.

    2001-01-01

    Within the framework of the European Fusion Technology Programme, FZK is involved in the research and development process for a vacuum pump system of a future fusion reactor. As a result of these activities, the concept and the necessary requirements for the primary vacuum system of the ITER fusion reactor were defined. Continuing that development process, FZK has been preparing the test facility TIMO (Test facility for ITER Model pump) since 1996. This test facility provides for testing a cryopump all needed infrastructure as for example a process gas supply including a metering system, a test vessel, the cryogenic supply for the different temperature levels and a gas analysing system. For manufacturing the ITER model pump an order was given to the company L' Air Liquide in the form of a NET contract. (author)

  16. Test facility TIMO for testing the ITER model cryopump

    International Nuclear Information System (INIS)

    Haas, H.; Day, C.; Mack, A.; Methe, S.; Boissin, J.C.; Schummer, P.; Murdoch, D.K.

    1999-01-01

    Within the framework of the European Fusion Technology Programme, FZK is involved in the research and development process for a vacuum pump system of a future fusion reactor. As a result of these activities, the concept and the necessary requirements for the primary vacuum system of the ITER fusion reactor were defined. Continuing that development process, FZK has been preparing the test facility TIMO (Test facility for ITER Model pump) since 1996. This test facility provides for testing a cryopump all needed infrastructure as for example a process gas supply including a metering system, a test vessel, the cryogenic supply for the different temperature levels and a gas analysing system. For manufacturing the ITER model pump an order was given to the company L'Air Liquide in the form of a NET contract. (author)

  17. Doserate mapping studies of the Multipurpose Gamma Irradiation Facility after hoist cable replacement

    International Nuclear Information System (INIS)

    Banini, G.K.; Emi-Reynolds, G.

    1998-01-01

    Irradiation of ethanol chlorobenzene dosimeters (ECB) in air have been carried out in an attempt to map out and confirm the gamma dose field for the inner and outer chambers of the Gamma Irradiation Facility at the Radiation Technology Centre after the replacement of the 5mm diameter stainless weak hoist cables by a 6mm one. The results obtained were compared with expected dose rate values (regressed from the suppliers readings) for the various positions within the irradiation chamber. Our study reveal that the replacement of the hoist cables have been done correctly within specifications and that the dose rate map has not been affected. The significance of the work to routine radiation processing are discussed. (author). 6 refs.; 8 figs

  18. Irradiation Testing Vehicles for Fast Reactors from Open Test Assemblies to Closed Loops

    Energy Technology Data Exchange (ETDEWEB)

    Sienicki, James J. [Argonne National Lab. (ANL), Argonne, IL (United States); Grandy, Christopher [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-15

    A review of irradiation testing vehicle approaches and designs that have been incorporated into past Sodium-Cooled Fast Reactors (SFRs) or envisioned for incorporation has been carried out. The objective is to understand the essential features of the approaches and designs so that they can inform test vehicle designs for a future U.S. Fast Test Reactor. Fast test reactor designs examined include EBR-II, FFTF, JOYO, BOR-60, PHÉNIX, JHR, and MBIR. Previous designers exhibited great ingenuity in overcoming design and operational challenges especially when the original reactor plant’s mission changed to an irradiation testing mission as in the EBRII reactor plant. The various irradiation testing vehicles can be categorized as: Uninstrumented open assemblies that fit into core locations; Instrumented open test assemblies that fit into special core locations; Self-contained closed loops; and External closed loops. A special emphasis is devoted to closed loops as they are regarded as a very desirable feature of a future U.S. Fast Test Reactor. Closed loops are an important technology for irradiation of fuels and materials in separate controlled environments. The impact of closed loops on the design of fast reactors is also discussed in this report.

  19. Oak Ridge rf Test Facility

    International Nuclear Information System (INIS)

    Gardner, W.L.; Hoffman, D.J.; McCurdy, H.C.; McManamy, T.J.; Moeller, J.A.; Ryan, P.M.

    1985-01-01

    The rf Test Facility (RFTF) of Oak Ridge National Laboratory (ORNL) provides a national facility for the testing and evaluation of steady-state, high-power (approx.1.0-MW) ion cyclotron resonance heating (ICRH) systems and components. The facility consists of a vacuum vessel and two fully tested superconducting development magnets from the ELMO Bumpy Torus Proof-of-Principle (EBT-P) program. These are arranged as a simple mirror with a mirror ratio of 4.8. The axial centerline distance between magnet throat centers is 112 cm. The vacuum vessel cavity has a large port (74 by 163 cm) and a test volume adequate for testing prototypic launchers for Doublet III-D (DIII-D), Tore Supra, and the Tokamak Fusion Test Reactor (TFTR). Attached to the internal vessel walls are water-cooled panels for removing the injected rf power. The magnets are capable of generating a steady-state field of approx.3 T on axis in the magnet throats. Steady-state plasmas are generated in the facility by cyclotron resonance breakdown using a dedicated 200-kW, 28-GHz gyrotron. Available rf sources cover a frequency range of 2 to 200 MHz at 1.5 kW and 3 to 18 MHz at 200 kW, with several sources at intermediate parameters. Available in July 1986 will be a >1.0-MW, cw source spanning 40 to 80 MHz. 5 figs

  20. Storage tests on irradiated deep-frozen chickens

    International Nuclear Information System (INIS)

    Gruenewald, T.

    1975-01-01

    Salmonellae infections in deep-frozen roasting chicken can be dealt with by ionising radiation as this process involves hardly any heating of the product. Deep-frozen chickens irradiated with doses up to 800 krad were stored at -30 0 C for two years and were regularly submitted to sensory tests. There was no significant difference in quality between the irradiated samples and the non-irradiated controls. (orig.) [de