WorldWideScience

Sample records for irradiation sources metodika

  1. Metodika výzkumu archeologických textilních nálezů

    Czech Academy of Sciences Publication Activity Database

    Bravermanová, M.; Březinová, Helena; Urbanová, K.

    2011-01-01

    Roč. 71, č. 2 (2011), s. 97-104 ISSN 1210-5538 R&D Projects: GA AV ČR KJB800020901 Institutional research plan: CEZ:AV0Z80020508 Keywords : archaeological textile finds * conditions of textile preservation * methodology * textile-technological survey * work hygiene Subject RIV: AC - Archeology, Anthropology, Ethnology http://www.npu.cz/download/1310125749/zpp-11-02-metodika-textil-bravermanova.pdf

  2. Irradiation device using radiation sources

    International Nuclear Information System (INIS)

    Perraudin, Claude; Amarge, Edmond; Guiho, J.-P.; Horiot, J.-C.; Taniel, Gerard; Viel, Georges; Brethon, J.-P.

    1981-01-01

    The invention refers to an irradiation appliance making use of radioactive sources such as cobalt 60. This invention concerns an irradiation appliance delivering an easily adjustable irradiation beam in accurate dimensions and enabling the radioactive sources to be changed without making use of intricate manipulations at the very place where the appliance has to be used. This kind of appliance is employed in radiotherapy [fr

  3. Cesium glass irradiation sources

    International Nuclear Information System (INIS)

    Plodinec, M.J.

    1982-01-01

    The precipitation process for the decontamination of soluble SRP wastes produces a material whose radioactivity is dominated by 137 Cs. Potentially, this material could be vitrified to produce irradiation sources similar to the Hanford CsCl sources. In this report, process steps necessary for the production of cesium glass irradiation sources (CGS), and the nature of the sources produced, are examined. Three options are considered in detail: direct vitrification of precipitation process waste; direct vitrification of this waste after organic destruction; and vitrification of cesium separated from the precipitation process waste. Direct vitrification is compatible with DWPF equipment, but process rates may be limited by high levels of combustible materials in the off-gas. Organic destruction would allow more rapid processing. In both cases, the source produced has a dose rate of 2 x 10 4 rads/hr at the surface. Cesium separation produces a source with a dose rate of 4 x 10 5 at the surface, which is nearer that of the Hanford sources (2 x 10 6 rads/hr). Additional processing steps would be required, as well as R and D to demonstrate that DWPF equipment is compatible with this intensely radioactive material

  4. Future radiation sources and identification of irradiated foods

    International Nuclear Information System (INIS)

    Brynjolfsson, A.

    1989-01-01

    Two major questions regarding irradiation that are raised today are: (1) Which sources should be used for irradiating food? and (2) How can irradiated foods be identified? This article considers both questions. After briefly mentioning a few of the historical stepping stones in the development of radiation sources, present and future radiation sources are discussed. Next the changes in foods caused by irradiation are considered. These changes are extremely small-so minor in fact that it is difficult to detect if the food has been irradiated. Still, these are several detection methods available, and this article describes them

  5. Materials for cold neutron sources: Cryogenic and irradiation effects

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1990-01-01

    Materials for the construction of cold neutron sources must satisfy a range of demands. The cryogenic temperature and irradiation create a severe environment. Candidate materials are identified and existing cold sources are briefly surveyed to determine which materials may be used. Aluminum- and magnesium-based alloys are the preferred materials. Existing data for the effects of cryogenic temperature and near-ambient irradiation on the mechanical properties of these alloys are briefly reviewed, and the very limited information on the effects of cryogenic irradiation are outlined. Generating mechanical property data under cold source operating conditions is a daunting prospect. It is clear that the cold source material will be degraded by neutron irradiation, and so the cold source must be designed as a brittle vessel. The continued effective operation of many different cold sources at a number of reactors makes it clear that this can be accomplished. 46 refs., 8 figs., 2 tab

  6. Standard Practice for Conducting Irradiations at Accelerator-Based Neutron Sources

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This practice covers procedures for irradiations at accelerator-based neutron sources. The discussion focuses on two types of sources, namely nearly monoenergetic 14-MeV neutrons from the deuterium-tritium T(d,n) interaction, and broad spectrum neutrons from stopping deuterium beams in thick beryllium or lithium targets. However, most of the recommendations also apply to other types of accelerator-based sources, including spallation neutron sources (1). Interest in spallation sources has increased recently due to their proposed use for transmutation of fission reactor waste (2). 1.2 Many of the experiments conducted using such neutron sources are intended to simulate irradiation in another neutron spectrum, for example, that from a DT fusion reaction. The word simulation is used here in a broad sense to imply an approximation of the relevant neutron irradiation environment. The degree of conformity can range from poor to nearly exact. In general, the intent of these simulations is to establish the fundam...

  7. Effects of irradiation source and dose level on quality characteristics of processed meat products

    Science.gov (United States)

    Ham, Youn-Kyung; Kim, Hyun-Wook; Hwang, Ko-Eun; Song, Dong-Heon; Kim, Yong-Jae; Choi, Yun-Sang; Song, Beom-Seok; Park, Jong-Heum; Kim, Cheon-Jei

    2017-01-01

    The effect of irradiation source (gamma-ray, electron-beam, and X-ray) and dose levels on the physicochemical, organoleptic and microbial properties of cooked beef patties and pork sausages was studied, during 10 days of storage at 30±1 °C. The processed meat products were irradiated at 0, 2.5, 5, 7.5, and 10 kGy by three different irradiation sources. The pH of cooked beef patties and pork sausages was unaffected by irradiation sources or their doses. The redness of beef patties linearly decreased with increasing dose level (Pchanges in overall acceptability were observed for pork sausages regardless of irradiation source (P>0.05), while gamma-ray irradiated beef patties showed significantly decreased overall acceptability in a dose-dependent manner (Poxidation of samples was accelerated by irradiation depending on irradiation sources and dose levels during storage at 30 °C. E-beam reduced total aerobic bacteria of beef patties more effectively, while gamma-ray considerably decreased microbes in pork sausages as irradiation dose increased. The results of this study indicate that quality attributes of meat products, in particular color, lipid oxidation, and microbial properties are significantly influenced by the irradiation sources.

  8. Isotope and machine sources for food irradiation

    International Nuclear Information System (INIS)

    Balcazar G, M.

    1992-05-01

    Artificial radioactive sources as Co-60 and Cs- 137 are produced by bombarding Co-59 with neutrons in a nuclear reactor and by chemical separation of spent nuclear fuel respectively. Both radioactive sources emit very high frequency electromagnetic radiation called y-rays. This highly penetrating radiation is employed for preservation of food. Each y-ray emitted from a radioactive source transports energy from the source to the irradiated food. Penetration of y-rays and their intensity depend on y-energy. Inside this study the advantages and disadvantages of both sources are compared. (Author)

  9. Isotope and machine sources for food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Balcazar G, M

    1992-05-15

    Artificial radioactive sources as Co-60 and Cs- 137 are produced by bombarding Co-59 with neutrons in a nuclear reactor and by chemical separation of spent nuclear fuel respectively. Both radioactive sources emit very high frequency electromagnetic radiation called y-rays. This highly penetrating radiation is employed for preservation of food. Each y-ray emitted from a radioactive source transports energy from the source to the irradiated food. Penetration of y-rays and their intensity depend on y-energy. Inside this study the advantages and disadvantages of both sources are compared. (Author)

  10. Piling up technology of goods irradiated by single plate source

    International Nuclear Information System (INIS)

    Xia Hezhou; Chen Yuxia; Cao Hongyun; Lin Yong; Zhou guoquan

    1999-01-01

    In the irradiation process of piling up goods in static state, four irradiation working sites and single plate source was adopted. The results showed that piling up in this way remarkably raised the irradiation quality of goods. The utilization rate of radioactive ray reached 22.27%

  11. Miniature sources of irradiation for intracavitary thermo radiotherapy

    Science.gov (United States)

    Taubin, M.; Chesnokov, D.; Simonov, A.

    2018-02-01

    This report presents the development of a miniature ionizing and thermal radiation source for oncological diseases treatment namely the inward parts of the body. This source can be placed next to the tumor inside of the body. This report is only about methods and devices for the intracavitary therapy. Irradiation by external sources wasn’t considered in our investigation.

  12. Materials irradiation subpanel report to BESAC neutron sources and research panel

    International Nuclear Information System (INIS)

    Birtcher, R.C.; Goland, A.N.; Lott, R.

    1992-01-01

    The future success of the nuclear power option in the US (fission and fusion) depends critically on the continued existence of a healthy national materials-irradiation program. Consideration of the requirements for acceptable materials-irradiation systems in a new neutron source has led the subcommittee to identify an advanced steady-state reactor (ANS) as a better choice than a spallation neutron source. However, the subcommittee also hastens to point out that the ANS cannot stand alone as the nation's sole high-flux mixed-spectrum neutron irradiation source in the next century. It must be incorporated in a broader program that includes other currently existing neutron irradiation facilities. Upgrading and continuing support for these facilities must be planned. In particular, serious consideration should be given to converting the HFIR into a dedicated materials test reactor, and long-term support for several university reactors should be established

  13. Irradiation Pattern Analysis for Designing Light Sources-Based on Light Emitting Diodes

    International Nuclear Information System (INIS)

    Rojas, E.; Stolik, S.; La Rosa, J. de; Valor, A.

    2016-01-01

    Nowadays it is possible to design light sources with a specific irradiation pattern for many applications. Light Emitting Diodes present features like high luminous efficiency, durability, reliability, flexibility, among others as the result of its rapid development. In this paper the analysis of the irradiation pattern of the light emitting diodes is presented. The approximation of these irradiation patterns to both, a Lambertian, as well as a Gaussian functions for the design of light sources is proposed. Finally, the obtained results and the functionality of bringing the irradiation pattern of the light emitting diodes to these functions are discussed. (Author)

  14. Endovascular Irradiations with beta sources

    Energy Technology Data Exchange (ETDEWEB)

    Scmidt, W F.O.; Hawliczek, R [Inst of Radiooncology IRO, Donauspital, Vienna (Austria); Mueck, K [Austrian Research Centre, Siebersdorf ARCS (Austria); Lehmann, D [Inst of Radiotherapy, Univ. Dresden (Germany); Pichler, L [Ludwig Boltzmann Institute for Endovascular Radiotherapy, Donauspital, Vienna (Austria)

    1999-12-31

    For treatment of restenoses tubes (inner/outer diameter 1 and 2 mm; length 3 or 5 mm) with Y-90 foils, shielded by Ti-layers on all sides have been developed (activity 0.5 - 2 GBq). Quality checks with plastic scintillators have been developed and are correlated to absolute dose measurements performed with TLDs (1x1 mm2; 40 mg/cm2). TLD-handling and calibration for beta-dosimetry are described. Additional measurements for depth-dose and dose distribution around the tubes were done with GAFCHROMIC- films and compared to Monte-Carlo calculations with the MCNP4-code, yielding a half-value depth of 0.8 mm from the tube-surface. Manufacturing and delivery of the sources including leakage tests has been standardized, treatments (irradiation times <5min; irradiation length <30mm) are planned to start in spring `98. (authors) 1 refs., 5 figs.

  15. The effects of different source arrangement on the irradiation efficacy

    International Nuclear Information System (INIS)

    Liu Hongyue; Shi Peixin; Lin Yin

    1999-01-01

    The effects of 8 different arrangements with 16 pencil sources on irradiation productivity were studied by using a self-designed computer program. The results showed that the fashion of decentralized arrangement had a higher irradiation productivity than that of centralized in a static and uniform field

  16. Neutron-irradiation facilities at the Intense Pulsed Neutron Source-I for fusion magnet materials studies

    International Nuclear Information System (INIS)

    Brown, B.S.; Blewitt, T.H.

    1982-01-01

    The decommissioning of reactor-based neutron sources in the USA has led to the development of a new generation of neutron sources that employ high-energy accelerators. Among the accelerator-based neutron sources presently in operation, the highest-flux source is the Intense Pulsed Neutron Source (IPNS), a user facility at Argonne National Laboratory. Neutrons in this source are produced by the interaction of 400 to 500 MeV protons with either of two 238 U target systems. In the Radiation Effects Facility (REF), the 238 U target is surrounded by Pb for neutron generatjion and reflection. The REF has three separate irradiation thimbles. Two thimbles provide irradiation temperatures between that of liquid He and several hundred degrees centigrade. The third thimble operates at ambient temperature. The large irradiation volume, the neutron spectrum and flux, the ability to transfer samples without warm up, and the dedication of the facilities during the irradiation make this ideally suited for radiation damage studies on components for superconducting fusion magnets. Possible experiments for fusion magnet materials are discussed on cyclic irradiation and annealing of stabilizers in a high magnetic field, mechanical tests on organic insulation irradiated at 4 K, and superconductors measured in high fields after irradiation

  17. Preliminary feasibility study on production of cobalt-60 source for industrial irradiation

    International Nuclear Information System (INIS)

    Joo, Po Kook; Park, Kyung Bae; Ahn, Yun Soo; Lee, Jong Tai; Kim, Hark Rho

    1999-05-01

    As there is a high possible demand of industrial Co-60 source in the world market, feasibility study of a project was performed to produce and to export Co-60 sources, utilizing KEPCO's Wolsung NPP for irradiation of cobalt and KAERI's hot-cells for fabrication of cobalt sources. Main concerns of the study were to understand irradiation and fabrication (encapsulation) processes and to examine related technologies, required facilities and equipment. In particular, it was examined intensively if it would be possible to modify facilities around the reactor vessel of Wolsung NPP tp substantiate the related licensing in order to irradiate cobalt in the reactor. It is expected that once, if cooperation scheme with MDS Nordion of Canada is established, main issues such as modification of facilities, related licensing, raw material procurement and technology transfer for high quality product will be solved. In order to review overall feasibility of the project, present status and prospect of the world market was surveyed and various usages of cobalt sources were reviewed with emphasis on possible demand increase per usage. Food poisoning accidents are prevailing worldwide and food irradiation with cobalt sources is considered as a promising measure to prevent them and may bring forth high increase of cobalt sources demand in the world market. Preliminary economic feasibility was studied in conservation, evaluating roughly the investment and the operating cost based on materials from various information sources. (author)

  18. Irradiation facilities at the advanced neutron source

    International Nuclear Information System (INIS)

    West, C.D.

    1992-01-01

    The Advanced Neutron Source (ANS) is a facility, centered around a new 330MW(f) heavy-water cooled and reflected research reactor, proposed for construction at Oak Ridge. The main scientific justification for the new source is the United States' need for increased capabilities in neutron scattering and other neutron beam research, but the technical objectives of the project also cater for the need to replace the irradiation facilities at the aging High Flux Isotope Reactor and to provide other research capabilities to the scientific community. This document provides a description of the ANS facilities

  19. Development of irradiator 60Co sources

    International Nuclear Information System (INIS)

    Mosca, Rodrigo C.; Moura, Eduardo S.; Zeituni, Carlos A.; Mathor, Monica B.

    2011-01-01

    According to a recent report by the International Agency for Research on Cancer (IARC) / WHO (2008-2010), the global impact of cancer more than doubled in 30 years. In this report, it was estimated that occurred about 12 million new cancer cases and 7 million deaths. In Brazil in 2010, with estimates for the year 2011, point to the occurrence of 489,270 new cases of cancer. Among the possibilities for cancer treatment, radiotherapy is one of the most important therapeutic and resources used to combat it. However, inherent complications of treatment can occur such as tiredness, loss of appetite, radiodermatitis and in more extreme cases late radionecrosis. In order to reproduce a point of radionecrosis in the vicinity of radiodermatitis to mimic these effects in animals, producing a model for assessment of tissue repair, we propose the setting up of an irradiator source of collimated 60 Co. The development of was based on 11 sources of 60 Co with 1 mm thickness that were inserted by inference in stainless steel 'gate-source' screw (patent pending) and later adjusted in a cross-shaped arrangement reinforced so that the beam radiation is directed to a target point, saving for other regions around this target point. The main use of this irradiator with sources of 60 Co is just one cause radionecrosis point (target point) of approximately 5 mm 2 with a surrounding and adjacent area of radiodermatitis around about 8 to 10 mm 2 in laboratory animals for subsequent coating with epidermal-dermal matrix populated by a cell culture of human fibroblasts, keratinocytes and mesenchymal stem cells. With that said, its use will be valuable for evaluation of curative treatments against the bone and radionecrosis or palliative treatment rather than as it is currently assumed. (author)

  20. Studies on the supposition of liquid source for irradiation and its dose distribution, (1)

    International Nuclear Information System (INIS)

    Yoshimura, Seiji; Nishida, Tsuneo

    1977-01-01

    Recently radio isotope has been used and applied in the respective spheres. The application of the effects by irradiation will be specially paid attention to in the future. Today the source for irradiation has been considered to be the thing sealed in the solid state into various capsules. So we suppose that we use liquid radio isotope as the source for irradiation. This is because there are some advantages compared with the solid source in its freedom of the shape or additional easiness at attenuation. In these experiments we measured the dose distribution by the columnar liquid source. We expect that these will be put to practical use. (auth.)

  1. A new irradiated quartz for beta source calibration

    DEFF Research Database (Denmark)

    Hansen, Vicki; Murray, Andrew Sean; Buylaert, Jan-Pieter

    2015-01-01

    For luminescence dating to be an accurate absolute dating technique it is very important that we are able to deliver absolutely known radiation doses in the laboratory. This is normally done using a radiation source (alpha, beta, X-ray) calibrated against an absolutely known reference source. Man...... doses from a standardised gamma source to in-built irradiation sources....... from south-western Denmark (Rømø). Two grain sizes (4-11μm and 180-250μm) have been examined in detail. These were pre-treated (annealed, dosed and annealed again) to sensitise and stabilise the luminescence signals before being given an absolutely known gamma dose from a point 137Cs source in scatter...

  2. Photoacoustic imaging driven by an interstitial irradiation source

    Directory of Open Access Journals (Sweden)

    Trevor Mitcham

    2015-06-01

    Full Text Available Photoacoustic (PA imaging has shown tremendous promise in providing valuable diagnostic and therapy-monitoring information in select clinical procedures. Many of these pursued applications, however, have been relatively superficial due to difficulties with delivering light deep into tissue. To address this limitation, this work investigates generating a PA image using an interstitial irradiation source with a clinical ultrasound (US system, which was shown to yield improved PA signal quality at distances beyond 13 mm and to provide improved spectral fidelity. Additionally, interstitially driven multi-wavelength PA imaging was able to provide accurate spectra of gold nanoshells and deoxyhemoglobin in excised prostate and liver tissue, respectively, and allowed for clear visualization of a wire at 7 cm in excised liver. This work demonstrates the potential of using a local irradiation source to extend the depth capabilities of future PA imaging techniques for minimally invasive interventional radiology procedures.

  3. A Study on Conjugate Heat Transfer Analysis of Reactor Vessel including Irradiated Structural Heat Source

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Kunwoo; Cho, Hyuksu; Im, Inyoung; Kim, Eunkee [KEPCO EnC, Daejeon (Korea, Republic of)

    2015-10-15

    Though Material reliability programs (MRPs) have a purpose to provide the evaluation or management methodologies for the operating RVI, the similar evaluation methodologies can be applied to the APR1400 fleet in the design stage for the evaluation of neutron irradiation effects. The purposes of this study are: to predict the thermal behavior whether or not irradiated structure heat source; to evaluate effective thermal conductivity (ETC) in relation to isotropic and anisotropic conductivity of porous media for APR1400 Reactor Vessel. The CFD simulations are performed so as to evaluate thermal behavior whether or not irradiated structure heat source and effective thermal conductivity for APR1400 Reactor Vessel. In respective of using irradiated structure heat source, the maximum temperature of fluid and core shroud for isotropic ETC are 325.8 .deg. C, 341.5 .deg. C. The total amount of irradiated structure heat source is about 5.41 MWth and not effect to fluid temperature.

  4. Limitation of population's irradiation by natural sources of ionizing radiation

    International Nuclear Information System (INIS)

    Krisyuk, Eh.M.

    1989-01-01

    Review of works devoted to evaluating the human irradiation doses at the expense of the main sources of ionizing radiation, is given. It is shown that the human irradiation doses at the expense of DDP can be reduced 10 times and more. However to realize such measures it is necessary to study the efficiency and determine the cost of various protective activities as well as to develop the criteria of their realization necessity

  5. Late changes in pig skin after irradiation from beta-emitting sources of different energy

    International Nuclear Information System (INIS)

    Hamlet, R.; Heryet, J.C.; Hopewell, J.W.; Wells, J.; Charles, M.W.

    1986-01-01

    Skin fields were irradiated on 3-month-old pigs with Sr 90 , Tm 170 and Pm 147 sources, ranging in size from 1mm to 22.5 mm in diameter. The severity of late skin atrophy was assessed 2 years after irradiation by a comparison of the thickness of the dermis in exposed skin with that of an adjacent area of unirradiated skin. Quantitative measurements were made from histological sections. The maximum dermal thinning after Sr 90 β-irradiation was approx. 55%. Irradiation with Tm 170 produced a maximal thinning of approximately 35%. Irradiation with Pm 147 produced no observable atrophy in pig skin. These differences reflect the different depth-dose characteristics of the three β-emitting sources. Significant late dermal atrophy was seen after doses which only produced a minimal erythema in the acute phase of the reaction. There was also a lack of a field-size effect for late atrophy with all but the two smallest Sr 90 sources. This is the converse of the marked field-size effects reported for the acute skin reactions. (author)

  6. Technology, safety, and costs of decommissioning a reference large irradiator and reference sealed sources

    Energy Technology Data Exchange (ETDEWEB)

    Haffner, D.R.; Villelgas, A.J. [Pacific Northwest Lab., Richland, WA (United States)

    1996-01-01

    This report contains the results of a study sponsored by the US Nuclear Regulatory Commission (NRC) to examine the decommissioning of large radioactive irradiators and their respective facilities, and a broad spectrum of sealed radioactive sources and their respective devices. Conceptual decommissioning activities are identified, and the technology, safety, and costs (in early 1993 dollars) associated with decommissioning the reference large irradiator and sealed source facilities are evaluated. The study provides bases and background data for possible future NRC rulemaking regarding decommissioning, for evaluation of the reasonableness of planned decommissioning actions, and for determining if adequate funds are reserved by the licensees for decommissioning of their large irradiator or sealed source facilities. Another purpose of this study is to provide background and information to assist licensees in planning and carrying out the decommissioning of their sealed radioactive sources and respective facilities.

  7. Technology, safety, and costs of decommissioning a reference large irradiator and reference sealed sources

    International Nuclear Information System (INIS)

    Haffner, D.R.; Villelgas, A.J.

    1996-01-01

    This report contains the results of a study sponsored by the US Nuclear Regulatory Commission (NRC) to examine the decommissioning of large radioactive irradiators and their respective facilities, and a broad spectrum of sealed radioactive sources and their respective devices. Conceptual decommissioning activities are identified, and the technology, safety, and costs (in early 1993 dollars) associated with decommissioning the reference large irradiator and sealed source facilities are evaluated. The study provides bases and background data for possible future NRC rulemaking regarding decommissioning, for evaluation of the reasonableness of planned decommissioning actions, and for determining if adequate funds are reserved by the licensees for decommissioning of their large irradiator or sealed source facilities. Another purpose of this study is to provide background and information to assist licensees in planning and carrying out the decommissioning of their sealed radioactive sources and respective facilities

  8. Development of irradiator {sup 60}Co sources

    Energy Technology Data Exchange (ETDEWEB)

    Mosca, Rodrigo C.; Moura, Eduardo S.; Zeituni, Carlos A.; Mathor, Monica B., E-mail: rcmosca@usp.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    According to a recent report by the International Agency for Research on Cancer (IARC) / WHO (2008-2010), the global impact of cancer more than doubled in 30 years. In this report, it was estimated that occurred about 12 million new cancer cases and 7 million deaths. In Brazil in 2010, with estimates for the year 2011, point to the occurrence of 489,270 new cases of cancer. Among the possibilities for cancer treatment, radiotherapy is one of the most important therapeutic and resources used to combat it. However, inherent complications of treatment can occur such as tiredness, loss of appetite, radiodermatitis and in more extreme cases late radionecrosis. In order to reproduce a point of radionecrosis in the vicinity of radiodermatitis to mimic these effects in animals, producing a model for assessment of tissue repair, we propose the setting up of an irradiator source of collimated {sup 60}Co. The development of was based on 11 sources of {sup 60}Co with 1 mm thickness that were inserted by inference in stainless steel 'gate-source' screw (patent pending) and later adjusted in a cross-shaped arrangement reinforced so that the beam radiation is directed to a target point, saving for other regions around this target point. The main use of this irradiator with sources of {sup 60}Co is just one cause radionecrosis point (target point) of approximately 5 mm{sup 2} with a surrounding and adjacent area of radiodermatitis around about 8 to 10 mm{sup 2} in laboratory animals for subsequent coating with epidermal-dermal matrix populated by a cell culture of human fibroblasts, keratinocytes and mesenchymal stem cells. With that said, its use will be valuable for evaluation of curative treatments against the bone and radionecrosis or palliative treatment rather than as it is currently assumed. (author)

  9. Source rack reload of the Tunisian gamma irradiation facility using Monte Carlo method

    International Nuclear Information System (INIS)

    Gharbi, Foued; Kadri, Omrane

    2005-01-01

    This work presents a Monte Carlo study of the cylindrical source rack geometry of the tunisian gamma irradiation facility, using Ge ant code of CERN. The study investigates the question of the reload of the source rack. studied configurations consist on housing four new pencils, two in the upper and two in the lower cylinder of the source rack. global dose rate uniformity inside a ''dummy's' product for the case of routine and non routine irradiation and as function of the product bulk density was calculated for eight hypothetical configurations. the same calculation was also performed for both of the original and the ideal, but not practical configuration. It was shown that hypothetical cases produced dose uniformity variations, according to product density, that were statistically no different than the original and the ideal configurations and that reload procedure can not improve the irradiation quality inside the tunisian facility

  10. Shielding of a neutron irradiator with {sup 241}Am-Be source

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, K.A.M. de; Crispim, V.R.; Silva, A.X., E-mail: koliveira@con.ufrj.b, E-mail: verginia@con.ufrj.b, E-mail: ademir@con.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear; Fonseca, E.S., E-mail: evaldo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The equivalent dose rates at 1.0 cm from the outer surface of the shielding of a neutron irradiation system that uses {sup 241}Am-Be source with activity of 185 GBq (5 Ci) were determined. A theoretical-experimental approach including case studies, through computer simulations with MCNP code was employed to calculate the best shielding thickness. Following the construction of the neutron irradiator, dose measurements were conducted in order to validate data obtained from simulation. The neutron irradiator shielding was designed in such a way to allow transport of the neutron radiography system for in loco inspections ensuring workers' radiologic safety. (author)

  11. Industrial gamma irradiation facility with a wet storage source in Syrian Arab Republic

    International Nuclear Information System (INIS)

    Othman, I.; Moussa, A.; Stepanov, D.G.; Ermakov, V.

    1998-01-01

    A gamma radiation facility was built in Damascus, Syria. The plant (ROBO) is a Co-60 wet storage, batch/continuous facility with nominal capacity of 1.85x10 16 Bq. The initial activity is 3.7x10 15 Bq. The ratio of maximum absorbed dose to the minimum one within irradiated materials is around 1.3+/-0.03. The irradiator consists of two sections to select required sources for irradiation. Two pools were constructed. The main pool will serve as biological shield for the main sources frame. The second pool will host a fixed circular frame to be used as calibration source or to irradiate small samples to low doses. The conveyor consists of a chain facility moving along trucks. A repair section is provided on the conveyor route in the load-unload area for carrying out inspection, repair, etc. The trucks are holed with a rectangular frames. Loading, unloading and rearrangement of the products is carried out automatically. This mechanism is carried out by seven pneumatic cylinders, lifting devices and roller conveyors. Many safety features were included: push-back platform, followed by pit used as a physical barrier. Interlocks are connected to the platform, pit cover and to ionization chambers. In case of power failure or any overriding of interlocks, the irradiator comes to emergency dropping. Ventilation system, fire system, emergency power and closed water purification system are indicated on control panel. The facility will be utilized for medical products sterilization, research and calibration

  12. Experimental study on the temperature conditions for rod and plane irradiators with 60Co source

    International Nuclear Information System (INIS)

    Stepanov, G.D.; Osipov, V.B.; Sarapkin, I.I.; Chizhikov, V.A.

    1977-01-01

    The formation of a temperature field of rod and flat 60 Co irradiators has been studied. The experiments are carried out on a gamma installation. It has been shown that for a stationary operating mode the maximum cassette temperature (when the cassette contains a 60 Co source) is 148 deg C at maximum permissible temperature of 250 deg C. When ampoules containing the sources with maximum activity (640 Ci) are loaded into cassettes they have the temperature of 184 deg C. The reciprocal screening influence of rod irradiators gives the temperature rise of 8-10 deg in each element. The irradiators under study reach a stationary thermal operating mode in 150 min after the sources are elevated to the operating position

  13. Irradiation facilities at the spallation neutron source SINQ

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, E.; Ledermann, J.; Aebersold, H.; Kuehne, G.; Kohlik, K. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    Four independent experiments for sample irradiation are under construction and in preparation for operational tests at the spallation source SINQ. Three of them are located inside a thermal beam port with end positions inside or near the moderator tank. The other experiment will be established at the end position of a super mirror lined neutron guide for applications with cold neutrons. (author) 3 figs., 1 tab., 6 refs.

  14. Irradiator design with large-volume source cylinders

    International Nuclear Information System (INIS)

    Eichholz, G.G.; Craft, T.F.; Suh, D.Y.

    1985-01-01

    To provide for economic utilization of prospective vitrified cesium-137 waste elements, a study was conducted for a conceptual irradiator system based on these elements for the commercial sterilization of sewage sludge for land spreading as fertilizer. A literature study showed that dried sludge could be sterilized more efficiently than wet. Adequate destruction of E. coli in sludge could be obtained with radiation doses as low as 150 kR. However, a dose of about 1 megarad is generally regarded as mandatory. Two cesium waste concentrations had been proposed. The one incorporating lower concentrations of Cs-137 and a surface dose of 20 kR/h was insufficiently active. Work, therefore, concentrated on the more active source cylinders, which are 18 cm in diameter with a specific activity of 16 to 17 Ci/cc. The conceptual design envisages the dry sludge passing horizontally by a conveyor system, past two rows of source elements in a three-pass array. A computer program has been developed to produce isodose contours and to calculate integrated doses for various source-target configurations

  15. Method and equipment to lead a cable-like material under an irradiation source

    International Nuclear Information System (INIS)

    Riesselmann, F.J.

    1975-01-01

    When irradiating cable-like material (cable jacketed with polyethylene) which is led through an irradiation source and is thus turned and twisted, no uniform irradiation and twist changes have so far been obtained. It is suggested to twist the cable before the first circuit by about 45 0 in one direction, after turning and the second circuit, to twist by about 90 0 in the other direction and to follow with a further two circuits with twisting. A suitable cable twisting device which works with discrete clamping jaw is described in detail. (UWI) [de

  16. Calculation of the isotope concentrations, source terms and radiation shielding of the SAFARI-1 irradiation products

    International Nuclear Information System (INIS)

    Stoker, C.C.; Ball, G.

    2000-01-01

    The ever increasing expansion of the irradiation product portfolio of the SAFARI-1 reactor leads to the need to routinely calculate the radio-isotope concentrations and source terms for the materials irradiated in the reactor accurately. In addition to this, the required shielding for the transportation and processing of these irradiation products needs to be determined. In this paper the calculational methodology applied is described with special attention given to the spectrum dependence of the one-group cross sections of selected SAFARI-1 irradiation materials and the consequent effect on the determination of the isotope concentrations and source terms. Comparisons of the calculated isotopic concentrations and dose rates with experimental analysis and measurements provide confidence in the calculational methodologies and data used. (author)

  17. Dislocation Climb Sources Activated by 1 MeV Electron Irradiation of Copper-Nickel Alloys

    DEFF Research Database (Denmark)

    Barlow, P.; Leffers, Torben

    1977-01-01

    Climb sources emitting dislocation loops are observed in Cu-Ni alloys during irradiation with 1 MeV electrons in a high voltage electron microscope. High source densities are found in alloys containing 5, 10 and 20% Ni, but sources are also observed in alloys containing 1 and 2% Ni. The range of ...

  18. IFMIF, a fusion relevant neutron source for material irradiation current status

    International Nuclear Information System (INIS)

    Knaster, J.; Chel, S.; Fischer, U.; Groeschel, F.; Heidinger, R.; Ibarra, A.; Micciche, G.; Möslang, A.; Sugimoto, M.; Wakai, E.

    2014-01-01

    The d-Li based International Fusion Materials Irradiation Facility (IFMIF) will provide a high neutron intensity neutron source with a suitable neutron spectrum to fulfil the requirements for testing and qualifying fusion materials under fusion reactor relevant irradiation conditions. The IFMIF project, presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase under the Broader Approach (BA) Agreement between Japan Government and EURATOM, aims at the construction and testing of the most challenging facility sub-systems, such as the first accelerator stage, the Li target and loop, and irradiation test modules, as well as the design of the entire facility, thus to be ready for the IFMIF construction with a clear understanding of schedule and cost at the termination of the BA mid-2017. The paper reviews the IFMIF facility and its principles, and reports on the status of the EVEDA activities and achievements

  19. Leakage of an irradiator source: The June 1988 Georgia RSI [Radiation Sterilizers, Inc.] incident

    International Nuclear Information System (INIS)

    1990-02-01

    On June 6, 1988, operators of a pool irradiator in Decatur, Georgia, were prevented by a safety system from raising sources from the pool. Radiation levels of 60 millirem per hour at the surface of the pool water were found, indicative of a leak of one or more of the 252 Cs-137 source capsules used at the irradiator. A summary of the Incident Evaluation Task Force's First Interim Report has been prepared for person's needing an overview of the incident and lessons learned to date. This report provides a summary of Agreement States' views and recommendations on some of the issues raised by the incident

  20. Security measurements and radiological protection in the source panoramic irradiators and storage in pool

    International Nuclear Information System (INIS)

    Del Valle O, C.

    1996-01-01

    The aim of this paper is to investigate and to study the safety and protecting measurements that must be taken into account in the design and the use of panoramic source irradiators with wet storage or pool, concerning to category IV. The generic characteristics in plants of kind, as well as their description, are mentioned in this paper. The devices, that comply the security and control systems based on their redundancy, diversity and independence, are examined. Likewise, it describes the design requirements of the overcast, of the irradiators, of the source frame, of the transporting system of product, of the procedure access, of the security system of the irradiator shelf control, of the irradiation room, of the irradiation storage pool, of the ventilation system, for the protection in case of fire of fire, for electric energy failures, for the warning symbols and signs. It contains scope about the organization and responsibilities that must be taken into account in plants of this type. A detailed plan has been made for its operation and maintenance, enclosing instructions and registers for this reason. The statement of emergency events and their respective answers, the analysis of cases and reasons that causes accidents and its implementation and regular inspection procedures for the improvement of the plant are also studied. (author). 2 refs

  1. Existing and projected neutron sources and low-temperature irradiation facilities in Germany

    International Nuclear Information System (INIS)

    Boening, K.

    1984-01-01

    In this paper, a contribution given at the Kyoto University Research Reactor Institute to the temporal meeting on the design of the facilities for high flux, low temperature irradiation is summarized. The following five subjects were discussed. The project of modernizing the swimming pool type research reactor FRM with 4 MW power at Munich is to achieve relatively high thermal neutron flux, and an extremely compact core is designed. The existing low temperature irradiation facility (LTIF) of the FRM is the most powerful in the world, and has been successfully operated more than 20 years. The fast and thermal neutron fluxes are 2.9 x 10 13 and 3.5 x 10 13 /cm 2 sec, respectively. The experimental techniques in the LTIF of the FRM, such as a measuring cryostat, the mounting of irradiated samples and so on, are described. The installation of new LTIFs in connection with the projects of advanced neutron sources in Germany is likely to be made in the modernized FRM at Garching, in the spallation neutron source SNQ at KFA Juelich and so on. The interesting problems in fundamental and applied researches with LTIFs, and the unusual application of LTIFs are shown. (Kako, I.)

  2. Guide for the preparation of applications for licenses for the use of self-contained dry source-storage irradiators. Second proposed Revision 1

    International Nuclear Information System (INIS)

    Bassin, N.

    1984-10-01

    The purpose of this regulatory guide is to provide assistance to applicants and licensees in preparing applications for new licenses, license amendments, and license renewals for the use of self-contained dry source-storage irradiators. These irradiators are constructed so that the sealed sources and the material being irradiated are contained in a shielded volume and there is no external radiation beam during the use of the irradiator. The radioisotopes most commonly used for these irradiators are cobalt-60 and cesium-137

  3. Vēja elektrostaciju ietekme uz putniem rudens migrācijas laikā Baltijas jūras piekrastē (Liepāja, Latvija): metodikas aprobācija un pirmie rezultāti

    OpenAIRE

    Krotova, Ieva

    2015-01-01

    Vēja enerģijas izmantošana ir potenciāli izdevīgs ziemeļvalstu atjaunojamo energoresursu avots, kas nerada regulāru gaisa, ūdens un augsnes piesārņojumu. Latvijas rietumu un ziemeļu daļas ir piemērotas vēja enerģijas iegūšanai. Svarīgs aspekts vēja enerģētikas attīstībā ir tās ietekme uz vidi un dzīvajiem organismiem. Teorētiskajā daļā tika veikts vēja enerģētikas teorijas un citu valstu vēja elektrostacijas (VES) ietekmes pētījumu metodikas un iegūto rezultātu apskats šādās tēmās – vēja ...

  4. Pathomorphologic aftereffects of chronic irradiation with γ-neutron source incorporated in the abdominal cavity (communication 2)

    International Nuclear Information System (INIS)

    Ivanov, A.E.; Vasilenko, V.T.; Kiselev, Yu.M.; Mosidze, T.G.; Krylova, A.I.; Suskova, V.S.

    1992-01-01

    The results were presented of radiometric and morphological studies of the viscera of dogs and sheep who lived 5 to 7 years with the Hertz-IR type γ-neutron standard radiation sources, implanted in the abdominal cavity. The most coarse dystrophic and sclerotic changes were found in the visceral sites adjacent to the radiation source or near it. It was suggested that spermatogenesis disorders resulting from chronic low-dose irradiation were due to not only the immediate action of ionizing radiation, but to total disorders of the trophicity of irradiated body as well

  5. REQUIREMENTS TO THE LIMITATION OF POPULATION EXPO-SURE FROM THE NATIRAL IONIZING IRRADIATION SOURCES IN INDUSTRIAL CONDITIONS

    Directory of Open Access Journals (Sweden)

    I. P. Stamat

    2010-01-01

    Full Text Available The paper presents conceptually new requirements to the limitation of population exposure from the natural ionizing irradiation sources in industrial conditions, introduced into Basic Sanitary Rules of Radiation Safety (OSPORB-99/2010. It is shown that, first of all, introduction of these requirements is aimed at the resolution of variety of previously existing serious contradictions in organization of radiation safety control and supervision for the impact of natural ionizing irradiation sources in industry.

  6. Development of sup 1 sup 9 sup 2 Ir radiation sources for intravascular irradiation

    CERN Document Server

    Kogure, H; Iwamoto, S; Iwata, K; Kawauchi, Y; Nagata, Y; Sorita, T; Suzuki, K

    2003-01-01

    Intravascular brachytherapy is a novel therapy for preventing the restenosis of coronary artery by use of low-dose irradiation. JAERI and Kyoto University have been developing sup 1 sup 9 sup 2 Ir radiation sources by the cooperative research project entitled as 'The research on safety and effectiveness of the intravascular brachytherapy for preventing restenosis of the coronary artery disease' since 1998. The radiation source was introduced into the stenosis through a catheter (a guide-tube to insert directly into vascular) to irradiate the diseased part. Ten sup 1 sup 9 sup 2 Ir seed sources (phi 0.4 mm x 2.5 mm) were positioned between nylon spacers (phi 0.3 mm x 1.0 mm) in a flexible covering tube and the tube was plugged with a core-wire; the tube was shrunk to fix the inside materials and the size is 0.46 mm in diameter and 3 m in length. The physically optimal design was determined to insert the radiation source easily into vascular and to get the dose uniformity in the diseased part. The production me...

  7. Disposal strategy of proton irradiated mercury from high power spallation sources

    International Nuclear Information System (INIS)

    Chiriki, Suresh

    2010-01-01

    Large spallation sources are intended to be constructed in Europe (EURISOL: nuclear physics research facility and ESS: European Spallation Source). These facilities would accumulate more than 20 metric tons of irradiated mercury in the target, which has to be treated as highly radioactive and chemo-toxic waste. Liquid waste cannot be tolerated in European repositories. As part of this work on safety/decommissioning of high-power spallation sources, our investigations were focused mainly to study experimentally and theoretically the solidification of liquid mercury waste (selection of an adequate solid mercury form and of an immobilization matrix, chemical engineering process studies on solidification/stabilization and on encapsulating in a matrix). Based on experimental results and supported by literature Hg-chalcogens (HgS, HgSe) will be more stable in repositories than amalgams. Our irradiation experimental studies on mercury waste revealed that mercury sulfide is a reasonable solid for disposal and shows larger stability in possible accidents with water ingress in a repository. Additionally immobilization of mercury in a cement matrix and polysiloxane matrix were tested. HgS formation from liquid target mercury by a wet process is identified as a suitable formation procedure. These investigations reveal that an almost 99.9% elementary Hg conversion can be achieved and that wet process can be reasonably handled under hot cell conditions. (orig.)

  8. Disposal strategy of proton irradiated mercury from high power spallation sources

    Energy Technology Data Exchange (ETDEWEB)

    Chiriki, Suresh

    2010-07-01

    Large spallation sources are intended to be constructed in Europe (EURISOL: nuclear physics research facility and ESS: European Spallation Source). These facilities would accumulate more than 20 metric tons of irradiated mercury in the target, which has to be treated as highly radioactive and chemo-toxic waste. Liquid waste cannot be tolerated in European repositories. As part of this work on safety/decommissioning of high-power spallation sources, our investigations were focused mainly to study experimentally and theoretically the solidification of liquid mercury waste (selection of an adequate solid mercury form and of an immobilization matrix, chemical engineering process studies on solidification/stabilization and on encapsulating in a matrix). Based on experimental results and supported by literature Hg-chalcogens (HgS, HgSe) will be more stable in repositories than amalgams. Our irradiation experimental studies on mercury waste revealed that mercury sulfide is a reasonable solid for disposal and shows larger stability in possible accidents with water ingress in a repository. Additionally immobilization of mercury in a cement matrix and polysiloxane matrix were tested. HgS formation from liquid target mercury by a wet process is identified as a suitable formation procedure. These investigations reveal that an almost 99.9% elementary Hg conversion can be achieved and that wet process can be reasonably handled under hot cell conditions. (orig.)

  9. Dosimetry and irradiation methods for the ANSTO gamma technology research irradiator (GATRI)

    International Nuclear Information System (INIS)

    Izard, M.E.

    1988-07-01

    The Australian Nuclear Science and Technology Organisation's gamma technology research irradiator (GATRI) at Lucas Heights, New South Wales, has been modified for use as a research and small-scale commercial irradiation facility to be available to government agencies and private industry for the technical and economic evaluation of irradiation processing. The new source rack was designed around existing mechanical components to optimise the limited space available within the irradiation cell. Irradiation parameters investigated during commissioning included the effect of source-to-target distance on relative dose rates within targets of the same density; effect of density on dose-rate distribution within targets irradiated at the same distance from the source; and the contribution of transit dose to low absorbed doses as the source is raised and lowered. The efficiency of the irradiator was determined for various target densities and overdose ratios

  10. Irradiation of goods

    International Nuclear Information System (INIS)

    Lunt, R.E.

    1987-01-01

    Mechanical handling apparatus is adapted to handle goods, such as boxed fruit, during a process of irradiation, in palletized form. Palletized goods are loaded onto wheeled vehicles in a loading zone. Four vehicles are wheeled on a track into an irradiation zone via a door in a concrete shield. The vehicles are arranged in orthogonal relationship around a source of square section. Turntables are positioned at corners of the square shaped rail truck around the source selectively to turn the vehicles to align then with track sections. Mechanical manipulating devices are positioned in the track sections opposed to sides of the source. During irradiation, the vehicles and their palletized goods are cylically moved toward the source to offer first sides of the goods for irradiation and are retraced from the source and are pivoted through 90 0 to persent succeeding sides of the goods for irradiation

  11. Gamma irradiation devices

    International Nuclear Information System (INIS)

    Foeldiak, Gabor; Stenger, Vilmos.

    1983-01-01

    The main parameters and the preparation procedures of the gamma radiation sources frequently applied for irradiation purposes are discussed. In addition to 60 Co and 137 Cs sources also the nuclear power plants offer further opportunities: spent fuel elements and products of certain (n,γ) reactions can serve as irradiation sources. Laboratory scale equipments, pilot plant facilities for batch or continuous operation, continuous industrial irradiators and special multipurpose, mobile and panorama type facilities are reviewed including those in Canada, USA, India, the Soviet Union, Hungary, UK, Japan and Australia. For irradiator design the source geometry dependence of the spatial distribution of dose rates can be calculated. (V.N.)

  12. Response-surface models for deterministic effects of localized irradiation of the skin by discrete {beta}/{gamma} -emitting sources

    Energy Technology Data Exchange (ETDEWEB)

    Scott, B.R.

    1995-12-01

    Individuals who work at nuclear reactor facilities can be at risk for deterministic effects in the skin from exposure to discrete {Beta}- and {gamma}-emitting ({Beta}{gamma}E) sources (e.g., {Beta}{gamma}E hot particles) on the skin or clothing. Deterministic effects are non-cancer effects that have a threshold and increase in severity as dose increases (e.g., ulcer in skin). Hot {Beta}{gamma}E particles are {sup 60}Co- or nuclear fuel-derived particles with diameters > 10 {mu}m and < 3 mm and contain at least 3.7 kBq (0.1 {mu}Ci) of radioactivity. For such {Beta}{gamma}E sources on the skin, it is the beta component of the dose that is most important. To develop exposure limitation systems that adequately control exposure of workers to discrete {Beta}{gamma}E sources, models are needed for systems that adequately control exposure of workers to discrete {Beta}{gamma}E sources, models are needed for evaluating the risk of deterministic effects of localized {Beta} irradiation of the skin. The purpose of this study was to develop dose-rate and irradiated-area dependent, response-surface models for evaluating risks of significant deterministic effects of localized irradiation of the skin by discrete {Beta}{gamma}E sources and to use modeling results to recommend approaches to limiting occupational exposure to such sources. The significance of the research results as follows: (1) response-surface models are now available for evaluating the risk of specific deterministic effects of localized irradiation of the skin; (2) modeling results have been used to recommend approaches to limiting occupational exposure of workers to {Beta} radiation from {Beta}{gamma}E sources on the skin or on clothing; and (3) the generic irradiated-volume, weighting-factor approach to limiting exposure can be applied to other organs including the eye, the ear, and organs of the respiratory or gastrointestinal tract and can be used for both deterministic and stochastic effects.

  13. Response-surface models for deterministic effects of localized irradiation of the skin by discrete β/γ -emitting sources

    International Nuclear Information System (INIS)

    Scott, B.R.

    1995-01-01

    Individuals who work at nuclear reactor facilities can be at risk for deterministic effects in the skin from exposure to discrete Β- and γ-emitting (ΒγE) sources (e.g., ΒγE hot particles) on the skin or clothing. Deterministic effects are non-cancer effects that have a threshold and increase in severity as dose increases (e.g., ulcer in skin). Hot ΒγE particles are 60 Co- or nuclear fuel-derived particles with diameters > 10 μm and < 3 mm and contain at least 3.7 kBq (0.1 μCi) of radioactivity. For such ΒγE sources on the skin, it is the beta component of the dose that is most important. To develop exposure limitation systems that adequately control exposure of workers to discrete ΒγE sources, models are needed for systems that adequately control exposure of workers to discrete ΒγE sources, models are needed for evaluating the risk of deterministic effects of localized Β irradiation of the skin. The purpose of this study was to develop dose-rate and irradiated-area dependent, response-surface models for evaluating risks of significant deterministic effects of localized irradiation of the skin by discrete ΒγE sources and to use modeling results to recommend approaches to limiting occupational exposure to such sources. The significance of the research results as follows: (1) response-surface models are now available for evaluating the risk of specific deterministic effects of localized irradiation of the skin; (2) modeling results have been used to recommend approaches to limiting occupational exposure of workers to Β radiation from ΒγE sources on the skin or on clothing; and (3) the generic irradiated-volume, weighting-factor approach to limiting exposure can be applied to other organs including the eye, the ear, and organs of the respiratory or gastrointestinal tract and can be used for both deterministic and stochastic effects

  14. Impacts of Irradiation Sources on Quality Attributes of Low-salt Sausage during Refrigerated Storage

    Science.gov (United States)

    Kim, Hyun-Wook; Choi, Yun-Sang

    2017-01-01

    This study was performed to investigate the impacts of irradiation sources on quality attributes of low-salt sausage during refrigerated storage. Control sausage was prepared with 1.5% sodium chloride (NaCl), whereas low-salt sausage was formulated with 0.75% NaCl (a 50% reduction; L-control). Sausage samples were vacuum-packaged, and low-sausages were irradiated with gamma-ray, electron-beam and X-ray at 5 kGy, respectively. The samples were stored at 4°C for 28 d to determine changes in quality attributes. The pH of low-salt sausages was unaffected by irradiation at 5 kGy (p>0.05). Higher redness values were found at irradiated low-salt sausages compared to control (psausage were higher than those of low-salt sausages (psausage treatments. The overall sensory acceptability score of irradiated/low-salt sausages were lower than L-control due to decreased scores for cooked meat flavor but increased radiolytic off-flavor (psausages were higher than control and L-control (psausages (psausages, and suggest that further studies should be necessary to reducing radiolytic off-flavor of irradiated/low-salt sausages. PMID:29147093

  15. Assessment of the gas dynamic trap mirror facility as intense neutron source for fusion material test irradiations

    International Nuclear Information System (INIS)

    Fischer, U.; Moeslang, A.; Ivanov, A.A.

    2000-01-01

    The gas dynamic trap (GDT) mirror machine has been proposed by the Budker Institute of nuclear physics, Novosibirsk, as a volumetric neutron source for fusion material test irradiations. On the basis of the GDT plasma confinement concept, 14 MeV neutrons are generated at high production rates in the two end sections of the axially symmetrical central mirror cell, serving as suitable irradiation test regions. In this paper, we present an assessment of the GDT as intense neutron source for fusion material test irradiations. This includes comparisons to irradiation conditions in fusion reactor systems (ITER, Demo) and the International Fusion Material Irradiation Facility (IFMIF), as well as a conceptual design for a helium-cooled tubular test assembly elaborated for the largest of the two test zones taking proper account of neutronics, thermal-hydraulic and mechanical aspects. This tubular test assembly incorporates ten rigs of about 200 cm length used for inserting instrumented test capsules with miniaturized specimens taking advantage of the 'small specimen test technology'. The proposed design allows individual temperatures in each of the rigs, and active heating systems inside the capsules ensures specimen temperature stability even during beam-off periods. The major concern is about the maximum achievable dpa accumulation of less than 15 dpa per full power year on the basis of the present design parameters of the GDT neutron source. A design upgrading is proposed to allow for higher neutron wall loadings in the material test regions

  16. Particle-in-cell simulation of electron trajectories and irradiation uniformity in an annular cathode high current pulsed electron beam source

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Wang, Langping, E-mail: aplpwang@hit.edu.cn; Zhou, Guangxue; Wang, Xiaofeng

    2017-02-01

    Highlights: • The transmission process of electrons and irradiation uniformity was simulated. • Influence of the irradiation parameters on irradiation uniformity are discussed. • High irradiation uniformity can be obtained in a wide processing window. - Abstract: In order to study electron trajectories in an annular cathode high current pulsed electron beam (HCPEB) source based on carbon fiber bunches, the transmission process of electrons emitted from the annular cathode was simulated using a particle-in-cell model with Monte Carlo collisions (PIC-MCC). The simulation results show that the intense flow of the electrons emitted from the annular cathode are expanded during the transmission process, and the uniformity of the electron distribution is improved in the transportation process. The irradiation current decreases with the irradiation distance and the pressure, and increases with the negative voltage. In addition, when the irradiation distance and the cathode voltage are larger than 40 mm and −15 kV, respectively, a uniform irradiation current distribution along the circumference of the anode can be obtained. The simulation results show that good irradiation uniformity of circular components can be achieved by this annular cathode HCPEB source.

  17. Methodology for the calculation of source terms related to irradiated fuel accumulated away from nuclear power plants

    International Nuclear Information System (INIS)

    Lima Filho, R.M.; Oliveira, L.F.S. de

    1984-01-01

    A general method for the calculation of the time evolution of source terms related to irradiated fuel is presented. Some applications are discussed which indicated that the method can provide important informations for the engineering design and safety analysis of a temporary storage facility of irradiated fuel elements. (Author) [pt

  18. Pathomorphology of the consequences of chronic irradiation from γ-neutron source implanted in abdominal cavity

    International Nuclear Information System (INIS)

    Ivanov, A.E.; Vasilenko, V.T.; Kiselev, Yu.M.; Mosidze, T.G.; Krylova, A.I.; Suskova, V.S.

    1989-01-01

    Comparison of the results of morphological investigations of the internal organs of dogs and sheep with γ-neutron radiation sources, implanted in the abdominal cavity, has shown that the correlation between a degree of severity and type of morphological changes in this case is similar to that of identical irradiation from an external source

  19. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of cobalt 60 give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of Co60 has created an insurance Quality System which insures the maximum of security for the user. (author)

  20. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of 60 Co give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of 60 Co has created an insurance Quality System which insures the maximum of security for the user

  1. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz, E-mail: hgomes@cnen.gov.b, E-mail: pbrito@cnen.gov.b, E-mail: cvroque@cnen.gov.b, E-mail: abrusqui@cnen.gov.b [Brazilian Nuclear Energy Commission (LAPOC/CNEN), Pocos de Caldas, MG (Brazil); Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana, E-mail: marciamh@ital.gov.b, E-mail: lucianam@ital.gov.b [Food Technology Institute (ITAL), SP (Brazil). Meat Technology Center

    2011-07-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and {alpha}-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h{sup -1}) and electron beam (2.9 kGy.s{sup -1}). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and {alpha}-tocopherol (A2). (author)

  2. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    International Nuclear Information System (INIS)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz; Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana

    2011-01-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and α-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h -1 ) and electron beam (2.9 kGy.s -1 ). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and α-tocopherol (A2). (author)

  3. Design of a permanent Cd-shielded epithermal neutron irradiation site in the Syrian Miniature Neutron Source Reactor

    International Nuclear Information System (INIS)

    Khattab, K.; Haddad, Kh.; Haj-Hassan, H.

    2008-01-01

    A Cd-shield (cylindrical shell 1 mm in thickness, 34 mm in diameter and 180 mm in length) was used to design a permanent epithermal neutron irradiation site for epithermal neutron activation analysis (ENAA) in the Syrian Miniature Neutron Source Reactor (MNSR). This site was achieved by shielding the surface of the aluminum tube of one of the outer irradiation sites. The calculated depression ratio of thermal neutron flux was 1/10. Homogeneity of the neutron flux in the first outer irradiation site has been found numerically using the WIMSD4 and CITATION codes and experimentally by irradiating five short copper wires using the outer irradiation capsule. Good agreement was obtained between the calculated and the measured results of the neutron flux distributions. (author)

  4. Design of a permanent Cd-shielded epithermal neutron irradiation site in the Syrian Miniature Neutron Source Reactor

    International Nuclear Information System (INIS)

    Khattab, K.; Haddad, Kh.; Haj-Hassan, H.

    2009-01-01

    A Cd-shield (cylindrical shell 1 mm in thickness, 34 mm in diameter and 180 mm in length) was used to design a permanent epithermal neutron irradiation site for epithermal neutron activation analysis (ENAA) in the Syrian Miniature Neutron Source Reactor (MNSR). This site was achieved by shielding the surface of the aluminum tube of one of the outer irradiation sites. The calculated depression ratio of thermal neutron flux was 1/10. Homogeneity of the neutron flux in the first outer irradiation site has been found numerically using the WIMSD4 and CITATION codes and experimentally by irradiating five short copper wires using the outer irradiation capsule. Good agreement was obtained between the calculated and the measured results of the neutron flux distributions. (author)

  5. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of 60 Co give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of 60 Co has created an insurance quality system which insures the maximum of security for the user. (orig.) [de

  6. Origin of irradiations by ionizing radiations

    International Nuclear Information System (INIS)

    Metivier, H.

    1998-01-01

    Irradiations by ionizing radiations proceed from two main sources: the natural radiations from the environment and the sources of 'human' origin, i.e. linked with modern technology. In most countries the irradiation by natural sources remains the most important. The irradiations for medical purposes comes in second position and depends on the degree of technological evolution of the country, and in the last position are the irradiations linked with nuclear industry. The inventory of these irradiations is regularly updated by the Scientific Committee of the United Nations for the study of ionizing radiation effects (UNSCEAR). In France the mean individual irradiation due to natural radioactivity is of 2 mSv per year of efficient dose and can vary with a factor 3 from one region to the other. Irradiation of medical diagnosis origin is of about 1 mSv per year. This paper presents successively: the natural irradiation sources (cosmic radiation, cosmic rays and cosmogenic radionuclides, the Earth's radiations, primary radionuclides and radon), the natural sources modified by the technology (extraction industries, fossil fuels and phosphated ores, aerial transports and space activities, consumer products), the irradiation sources of technological origin (nuclear weapons, electric power production, major accidents, occupational irradiations), and the medical irradiations (diagnosis techniques, radiology, nuclear medicine and therapeutic uses). (J.S.)

  7. Chapter 2: Irradiators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2018-04-01

    The chapter 2 presents the subjects: 1) gamma irradiators which includes: Category-I gamma irradiators (self-contained); Category-II gamma irradiators (panoramic and dry storage); Category-III gamma irradiators (self-contained in water); Category-IV gamma irradiators (panoramic and wet storage); source rack for Category-IV gamma irradiators; product transport system for Category-IV gamma irradiators; radiation shield for gamma irradiators; 2) accelerators which includes: Category-I Accelerators (shielded irradiator); Category-II Accelerators (irradiator inside a shielded room); Irradiation application examples.

  8. Design of YCF-1 mobile γ irradiator

    International Nuclear Information System (INIS)

    Zhang Hehu; Wang Chuanzhen

    1993-01-01

    YCF-1 mobile irradiator has been designed by Beijing Institute of Nuclear Engineering of China and has been put into use in Jilin province. It can play an important role in extending irradiation technology in food irradiation, disinfestation, sterilization and quarantine. This paper describes the features and design considerations of a mobile irradiator. The irradiator uses a Cesium-137 source, the design loading capacity of the source is 9.25 PBq (250 kCi). The half-life of Cs-137 is 30.2 years and the source does not need replacing. The dose rate on the surface is 0.0025 mSv/h in accordance with national standards. The shielding of the irradiation room is a steel shell filled with lead. The thickness of lead is 18 cm. The irradiator is installed on a special flat truck. The weight of the irradiator is more than 80 tons. The main components and parts of the irradiator are: source, source racks and hoist, irradiation chamber, storage source chamber, the product's transport system, dose monitoring system, ventilation system and safety interlock system. (author)

  9. Effect of antioxidants on thiobarbituric acid reactive substances, psychrotrophic bacteria and functional properties of mechanically deboned chicken meat irradiated with Cobalto-60 and electron beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Pomarico Neto, Walter, E-mail: hgomes@cnen.gov.br, E-mail: pbrito@cnen.gov.br, E-mail: cvroque@cnen.gov.br, E-mail: abrusqui@cnen.gov.br [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas; Mourao, Gerson Barreto; Orlando, Eduardo Adilson; Miyagusku, Luciana, E-mail: marciamh@ital.sp.gov.br, E-mail: eduardo.orlando@ital.sp.gov.br [Instituto de Tecnologia dos Alimentos (ITAL), Campinas, SP (Brazil)

    2013-07-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 (Sodium Polyphosphate and Sodium Ascorbate and Antioxidant 2 (Rosemary Extract and α-Tocopherol. The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (C), with antioxidant A1 and non-irradiated (A1), with antioxidant A2 and non-irradiated (A2) without antioxidant and irradiated in Cobalt-60 source (Co), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). The samples was conditioned in a transparent, low density frozen overnight at a temperature of -18 ± 1 deg C in a chamber, and irradiated in this state with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy/h) and electron beam (7.86 kGy/s). After this process, the samples were evaluated during the refrigeration period (2 ± 1 deg C) for 11 days for the following analysis: total psychrotrophic bacteria count and thiobarbituric acid reactive substances (TBARS) and the analysis of functional properties were performed after the irradiation process. The use of the combination of rosemary antioxidant and α-tocopherol were able to significantly decrease TBARS values caused by the irradiation of samples in MDCM cobalt-60 sources and electron beam, and show a synergetic effect to processing with ionizing radiation to reduce of psychrotrophic bacteria count. The use of irradiation processing of MDCM did not negatively affect the functional properties studied. (author)

  10. Effect of antioxidants on thiobarbituric acid reactive substances, psychrotrophic bacteria and functional properties of mechanically deboned chicken meat irradiated with Cobalto-60 and electron beam sources

    International Nuclear Information System (INIS)

    Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Pomarico Neto, Walter

    2013-01-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 (Sodium Polyphosphate and Sodium Ascorbate and Antioxidant 2 (Rosemary Extract and α-Tocopherol. The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (C), with antioxidant A1 and non-irradiated (A1), with antioxidant A2 and non-irradiated (A2) without antioxidant and irradiated in Cobalt-60 source (Co), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). The samples was conditioned in a transparent, low density frozen overnight at a temperature of -18 ± 1 deg C in a chamber, and irradiated in this state with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy/h) and electron beam (7.86 kGy/s). After this process, the samples were evaluated during the refrigeration period (2 ± 1 deg C) for 11 days for the following analysis: total psychrotrophic bacteria count and thiobarbituric acid reactive substances (TBARS) and the analysis of functional properties were performed after the irradiation process. The use of the combination of rosemary antioxidant and α-tocopherol were able to significantly decrease TBARS values caused by the irradiation of samples in MDCM cobalt-60 sources and electron beam, and show a synergetic effect to processing with ionizing radiation to reduce of psychrotrophic bacteria count. The use of irradiation processing of MDCM did not negatively affect the functional properties studied. (author)

  11. C-188 Co-60 sources installation and source rack loading optimization processes in a gamma irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo de S.; Vasquez, Pablo A.S., E-mail: psantos@ipen.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Since 2004, the Multipurpose Gamma Facility at the Nuclear and Energy Research Institute has been providing services on radiation processing for disinfection and sterilization of health care and disposable medical products as well to support research studies on modification of physical, chemical and biological properties of several materials. Recently, there was an increment in irradiation of the Cultural Heritages. This facility uses C-188 double-encapsulated radioactive Cobalt-60 sources known as pencils from manufactures outside of country. The activity of the cobalt sources decays into a stable nickel isotope with a half-life around 5.27 years, which means a loss of 12.3% annually. Then, additional pencils of Cobalt-60 are added periodically to the source rack to maintain the required capacity or installed activity of the facility. The manufacturer makes shipping of the radioactive sources inside a high density container type B(U) , by sea. This one involves many administrative, transport and radiation safety procedures. Once in the facility, the container is opened inside a deep pool water to remove the pencils. The required source geometry of the facility is obtained by loading these source pencils into predetermined diagram or positions in source modules and distributing these modules over the source rack of the facility. The dose variation can be reduced placing the higher activity source pencils near the periphery of the source rack. In this work are presented the procedures for perform the boiling leaching tests applied to the container, the Cobalt-60 sources installation, the loading processes and the source rack loading optimization. (author)

  12. Economics of food irradiation

    International Nuclear Information System (INIS)

    Deitch, J.

    1982-01-01

    This article examines the cost competitiveness of the food irradiation process. An analysis of the principal factors--the product, physical plant, irradiation source, and financing--that impact on cost is made. Equations are developed and used to calculate the size of the source for planned product throughput, efficiency factors, power requirements, and operating costs of sources, radionuclides, and accelerators. Methods of financing and capital investment are discussed. A series of tables show cost breakdowns of sources, buildings, equipment, and essential support facilities for both a cobalt-60 and a 10-MeV electron accelerator facility. Additional tables present irradiation costs as functions of a number of parameters--power input, source size, dose, and hours of annual operation. The use of the numbers in the tables are explained by examples of calculations of the irradiation costs for disinfestation of grains and radicidation of feed

  13. Experimental research on specific activity of 24Na using Chinese reference man phantom irradiated by 252Cf neutrons source

    International Nuclear Information System (INIS)

    Wang Yuexing; Yang Yifang; Lu Yongjie; Zhang Jianguo; Xing Hongchuan

    2011-01-01

    Objective: To investigate the specific activity of '2 4 Na per unit neutron fluence, A B/Φ ,in blood produced for Chinese reference man irradiated by 252 Cf neutron source,and to analyze the effects of scattering neutrons from ground,wall,and ceiling in irradiation site on it.Methods: A 252 Cf neutron source of 3×10 8 n/s and the anthropomorphic phantom were used for experiments. The phantom was made from 4 mm thick of outer covering by perspex and the liquid tissue-equivalent substitute in it. The data of phantom dimensions fit into Chinese reference man.The weight ratios of H, N, O and C in substitute equal from source to long axis of phantom were 1.1, 2.1, 3.1 and 4.1 m, respectively. Both the neutron source and the position of xiphisternum of the phantom were 1.6 m above the floor. Results: The average specific activity of 24 Na per unit neutron fluence was related to the irradiation-distances, d, and its maximum value, A B/ΦM , deduced by experimental data was about 1.85×10 -7 Bq·cm 2 ·g -1 . Conclusions: The A B/ΦM corresponds to that of phantom irradiated by plane-parallel beams, and the value is about more 3% than that by BOMAB phantom reported in literature. It has shown that floor-(wall-)scattered neutrons in irradiation site have significant contribution to the specific activity of 24 Na, but they contributed relatively little to the induced neutron doses. Consequently,using the specific activity of 24 Na for assessing accidental neutron doses received by an individual, the contribution of scattered neutrons in accident site will lead dose to be overestimated, and need to be correct. (authors)

  14. IFMIF [International Fusion Materials Irradiation Facility], an accelerator-based neutron source for fusion components irradiation testing: Materials testing capabilities

    International Nuclear Information System (INIS)

    Mann, F.M.

    1988-08-01

    The International Fusion Materials Irradiation Facility (IFMIF) is proposed as an advanced accelerator-based neutron source for high-flux irradiation testing of large-sized fusion reactor components. The facility would require only small extensions to existing accelerator and target technology originally developed for the Fusion Materials Irradiation Test (FMIT) facility. At the extended facility, neutrons would be produced by a 0.1-A beam of 35-MeV deuterons incident upon a liquid lithium target. The volume available for high-flux (>10/sup 15/ n/cm/sup 2/-s) testing in IFMITF would be over a liter, a factor of about three larger than in the FMIT facility. This is because the effective beam current of 35-MeV deuterons on target can be increased by a factor of ten to 1A or more. Such an increase can be accomplished by funneling beams of deuterium ions from the radio-frequency quadruple into a linear accelerator and by taking advantage of recent developments in accelerator technology. Multiple beams and large total current allow great variety in available testing. For example, multiple simultaneous experiments, and great flexibility in tailoring spatial distributions of flux and spectra can be achieved. 5 refs., 2 figs., 1 tab

  15. Practical design of gamma irradiation facility

    International Nuclear Information System (INIS)

    Sugimoto, Sen-ichi

    1976-01-01

    In this report, it is intended to describe mainly the multi-purpose irradiation facilities which carry out the consigned irradiation for the sterilization of medical apparatuses, which is most of the demand of gamma irradiation in Japan. Gamma irradiation criterion is summed up to that ''Apply the specified dose properly and uniformly to product cases and be economic.'' Though the establishment of the design standard for irradiation facilities is not easy and is not solve simply, the factors to be considered in the design are as follows: (1) mechanism safety, (2) multipurpose irradiation structure, (3) irradiation criteria and practice, (4) efficiency of radiation source utilization and related problems, and (5) economical merit. Irradiation facilities are generally itemized as follows: irradiation equipments, radiation source-storing facility, package carrier, radiation source-driving equipments, facilities for safety and operational management and others. Examples and their characteristics are reported for the facilities of Japan Radio-isotope Irradiation Cooperative Association and Radie Industries Ltd. Expenses for construction, processing and radiation sources are shown on the basis of a few references, and the cost trially calculated under a certain presumptive condition is given. (Wakatsuki, Y.)

  16. Dose characterization of the rad sourceTM 2400 X-ray irradiator for oyster pasteurization

    International Nuclear Information System (INIS)

    Wagner, Jennifer Koop; Dillon, Jeff A.; Blythe, Eugene K.; Ford, John R.

    2009-01-01

    The RS 2400's cylindrical X-ray source yields dose rates high enough to allow the irradiator to replace widely used gamma irradiators. Except for the leftmost 5 cm, beam uniformity is within 10% at the tube surface. At maximum operating parameters, the beam has HVL 1 =13.66 mm aluminum, HC=0.47, and hν eq =88.5 keV. Maximum dose rates to tissue are 65 Gy min -1 ±3.1% at tube surface, 37 Gy min -1 ±3.1% at center of canisters, 14.1 Gy min -1 ±6.5% for thin-shelled oysters, and 12.3 Gy min -1 ±6.2% for thick-shelled oysters

  17. Characterization of neutron flux spectra in the irradiation sites of a 37 GBq {sup 241}Am-Be isotopic source

    Energy Technology Data Exchange (ETDEWEB)

    Yücel, Haluk [Ankara University, Institute of Nuclear Sciences, 06100 Tandogan, Ankara (Turkey); Budak, Mustafa Guray, E-mail: mbudak@gazi.edu.tr [Gazi University, Gazi Education Faculty, 06500 Teknikokullar, Ankara (Turkey); Karadag, Mustafa [Gazi University, Gazi Education Faculty, 06500 Teknikokullar, Ankara (Turkey); Yüksel, Alptuğ Özer [Ankara University, Institute of Nuclear Sciences, 06100 Tandogan, Ankara (Turkey)

    2014-11-01

    Highlights: • An irradiation unit was installed using a 37 GBq {sup 241}Am-Be neutron source. • The source neutrons moderated by using both water and paraffin. • Irradiation unit was shielded by boron oxide and lead against neutrons and gammas. • There are two sites for irradiations, one of them has a pneumatic transfer system. • Cadmium ratio method was used for irradiation site characterization. - Abstract: For the applicability of instrumental neutron activation analysis (NAA) technique, an irradiation unit with a 37 GBq {sup 241}Am-Be neutron source was installed at Institute of Nuclear Sciences of Ankara University. Design and configuration properties of the irradiation unit are described. It has two different sample irradiation positions, one is called site #1 having a pneumatic sample transfer system and the other is site #2 having a location for manual use. In order to characterize neutron flux spectra in the irradiation sites, the measurement results were obtained for thermal (φ{sub th}) and epithermal neutron fluxes (φ{sub epi}), thermal to epithermal flux ratio (f) and epithermal spectrum shaping factors (α) by employing cadmium ratios of gold (Au) and molybdenum (Mo) monitors. The activities produced in these foils were measured by using a p-type, 44.8% relative efficiency HPGe well detector. For the measured γ-rays, self-absorption and true coincidence summing effects were taken into account. Additionally, thermal neutron self-shielding and resonance neutron self-shielding effects were taken into account in the measured results. For characterization of site #1, the required parameters were found to be φ{sub th} = (2.11 ± 0.05) × 10{sup 3} n cm{sup −2} s{sup −1}, φ{sub epi} = (3.32 ± 0.17) × 10{sup 1} n cm{sup −2} s{sup −1}, f = 63.6 ± 1.5, α = 0.045 ± 0.009, respectively. Similarly, those parameters were measured in site #2 as φ{sub th} = (1.49 ± 0.04) × 10{sup 3} n cm{sup −2} s{sup −1}, φ{sub epi} = (2.93 ± 0

  18. Structural and physico-mechanical properties of natural rubber/GTR composites devulcanized by microwaves: influence of GTR source and irradiation time

    OpenAIRE

    Colom Fajula, Xavier; Marin-Genesca, Marc; Mujal Rosas, Ramón María; Formela, Krzysztof; Cañavate Ávila, Francisco Javier

    2018-01-01

    Ground tire rubber from car and truck was modified using microwave irradiation at variable time. The irradiated ground tire rubber was used as filler in composites based on natural rubber. The composites, with high content of ground tire rubber, were prepared using an internal batch mixer and subsequently cross-linked at 160¿. The influence of the ground tire rubber source (car/truck) and irradiation time on structure, physico-mechanical behaviour, thermal properties and morphology of natural...

  19. Combined stereotactic biopsy and stepping-source interstitial irradiation of glioblastoma multiforme.

    Science.gov (United States)

    Brehmer, Stefanie; Guthier, Christian V; Clausen, Sven; Schneider, Frank; Schulte, Dirk-Michael; Benker, Matthias; Bludau, Frederic; Glatting, Gerhard; Marx, Alexander; Schmiedek, Peter; Hesser, Jürgen; Wenz, Frederik; Giordano, Frank A

    2018-04-01

    Patients diagnosed with glioblastoma multiforme receiving stereotactic biopsy only either due to tumor localization or impaired clinical status face a devastating prognosis with very short survival times. One strategy to provide an initial cytoreductive and palliative therapy at the time of the stereotactic biopsy is interstitial irradiation through the pre-defined trajectory of the biopsy channel. We designed a novel treatment planning system and evaluated the treatment potential of a fixed-source and a stepping-source algorithm for interstitial radiosurgery on non-spherical glioblastoma in direct adjacency to risk structures. Using both setups, we show that radiation doses delivered to 100% of the gross tumor volume shifts from sub-therapeutic (10-12 Gy) to sterilizing single doses (25-30 Gy) when using the stepping source algorithm due to improved sparing of organs-at-risk. Specifically, the maximum doses at the brain stem were 100% of the PTV dose when a fixed central source and 38% when a stepping-source algorithm was used. We also demonstrated precision of intracranial target points and stability of superficial and deep trajectories using both a phantom and a body donor study. Our setup now for the first time provides a basis for a clinical proof-of-concept trial and may widen palliation options for patients with limited life expectancy that should not undergo time-consuming therapies.

  20. Irradiation damage of ferritic/martensitic steels: Fusion program data applied to a spallation neutron source

    International Nuclear Information System (INIS)

    Klueh, R.L.

    1997-01-01

    Ferritic/martensitic steels were chosen as candidates for future fusion power plants because of their superior swelling resistance and better thermal properties than austenitic stainless steels. For the same reasons, these steels are being considered for the target structure of a spallation neutron source, where the structural materials will experience even more extreme irradiation conditions than expected in a fusion power plant first wall (i.e., high-energy neutrons that produce large amounts of displacement damage and transmutation helium). Extensive studies on the effects of neutron irradiation on the mechanical properties of ferritic/martensitic steels indicate that the major problem involves the effect of irradiation on fracture, as determined by a Charpy impact test. There are indications that helium can affect the impact behavior. Even more helium will be produced in a spallation neutron target material than in the first wall of a fusion power plant, making helium effects a prime concern for both applications. 39 refs., 10 figs

  1. Report on salvage of a jammed cobalt-60 source of the gamma beam irradiator at Bangladesh Institute of Nuclear Agriculture (BINA), Mymensingh, Bangladesh

    International Nuclear Information System (INIS)

    Karim, S.M.F.; Awal, K.O.; Ali, M.A.T.

    1997-01-01

    This report is the follow-up of a recovery plan for a Co-60 source that was presented at the proceedings of a symposium at the International Atomic Energy Agency, Vienna during 6-10 November 1989. This report deals mainly with technical measures adopted to salvage the jammed Co-60 source of a gamma irradiator at the Bangladesh Institute of Nuclear Agriculture BINA, Mymensingh, Bangladesh. Different tools and devices were developed to allow the remote recovery of the source. The radiation safety measures taken and the device drawings are given, together with suggestions for future use of the source with the remaining activity for irradiation purposes. (author)

  2. Dose characterization of the rad source{sup TM} 2400 X-ray irradiator for oyster pasteurization

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Jennifer Koop [Department of Nuclear Engineering, Texas A and M University, College Station, TX 77843-3133 (United States)], E-mail: jenkoop@gmail.com; Dillon, Jeff A. [Experimental Seafood Processing Laboratory, Mississippi State University, Pascagoula, MS 39567 (United States); Blythe, Eugene K. [Coastal Research and Extension Center, Mississippi State University, South Mississippi Branch Experiment Station, Poplarville, MS 39470 (United States); Ford, John R. [Department of Nuclear Engineering, Texas A and M University, College Station, TX 77843-3133 (United States)

    2009-02-15

    The RS 2400's cylindrical X-ray source yields dose rates high enough to allow the irradiator to replace widely used gamma irradiators. Except for the leftmost 5 cm, beam uniformity is within 10% at the tube surface. At maximum operating parameters, the beam has HVL{sub 1}=13.66 mm aluminum, HC=0.47, and h{nu}{sub eq}=88.5 keV. Maximum dose rates to tissue are 65 Gy min{sup -1}{+-}3.1% at tube surface, 37 Gy min{sup -1}{+-}3.1% at center of canisters, 14.1 Gy min{sup -1}{+-}6.5% for thin-shelled oysters, and 12.3 Gy min{sup -1}{+-}6.2% for thick-shelled oysters.

  3. Long-term follow-up after accidental gamma irradiation from a 60Co source

    International Nuclear Information System (INIS)

    Klener, V.; Tuscany, R.; Vejlupkova, J.; Dvorak, J.; Vlkovic, P.

    1986-01-01

    In December 1973 a technician was accidentally irradiated when attempting to bring under control a sealed 60 Co source (110 TBq) which had been lodged in the head of a medical irradiation unit during a replacement operation. In the early period after the accident, severe skin changes on the left hand, epilation in a small area of the left temporal region and minor deviations in peripheral blood developed. In the following years, repeated surgery due to secondary skin defects of the left hand resulted in the loss of the fingers 2-5. Since 1975, changes in the lens of the left eye began to appear leading gradually to the deterioration of visual acuity. Later, opacities of the lens of the right eye were found. The patient's psychological and emotional attitude about the accident changed in the course of time. The factors influencing the psychic state of the patient are identified

  4. Gemstone dedicated gamma irradiation development

    Energy Technology Data Exchange (ETDEWEB)

    Omi, Nelson M.; Rela, Paulo R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: nminoru@ipen.br; prela@ipen.br

    2007-07-01

    The gemstones gamma irradiation process to enhance the color is widely accepted for the jewelry industry. These gems are processed in conventional industrial gamma irradiation plant which are optimized for other purposes, using underwater irradiation devices with high rejection rate due to its poor dose uniformity. A new conception design, which states the working principles and manufacturing ways of the device, was developed in this work. The suggested device's design is based on the rotation of cylindrical baskets and their translation in circular paths inside and outside a cylindrical source rack as a planetary system. The device is meant to perform the irradiation in the bottom of the source storage pool, where the sources remain always shielded by the water layer. The irradiator matches the Category III IAEA classification. To verify the physical viability of the basic principle, tests with rotating cylindrical baskets were performed in the Multipurpose Irradiator constructed in the CTR, IPEN. Also, simulations using the CADGAMMA software, adapted to simulate underwater irradiations, were performed. With the definitive optimized irradiator, the irradiation quality will be enhanced with better dose control and the production costs will be significantly lower than market prices due to the intended treatment device's optimization. This work presents some optimization parameters and the expected performance of the irradiator. (author)

  5. Development of an irradiation system for a small size continuous run multipurpose gamma irradiator

    International Nuclear Information System (INIS)

    Calvo, W.A.P.; Rela, P.R.; Napolitano, C.M.; Kodama, Y.; Omi, N.M.; Costa, F.E. da; Andradee Silva, L.G. de

    2009-01-01

    The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m 2 of floor area, the irradiator design is a product overlap sources and the maximum capacity of cobalt-60 wet sources is 37 PBq. The performed qualification program of this multipurpose irradiator was based on AAMI/ISO 11137 standard, which recommends the inclusion of the following elements: installation and process qualification. The initial load of the multipurpose irradiator was 3.4 PBq with 13 cobalt-60 sources model C-188, supplied by MDS Nordion - Canada. For irradiator dose optimization, the source distribution was done using the software Cadgamma developed by IPEN-CNEN/SP. The polymethylmetacrylate (PMMA) dosimeter system, certified by the International Dose Assurance Service (IDAS) of the International Atomic Energy Agency (IAEA) was used for irradiator dose mapping. The economic analysis, performance concerning with dose uniformity and cobalt-60 utilization efficiency were calculated and compared with other commercial gamma irradiators available on the market. (authors)

  6. Parametric relationships for gamma dose and irradiation homogeneity in a sewage sludge irradiator

    International Nuclear Information System (INIS)

    Krishnamurthy, K.

    1986-01-01

    A study on the inter-relationships between factors governing γ dose and irradiation homogeneity in a sewage sludge irradiator is presented here. The analysis involves a 60 Co irradiator of cylindrical irradiation geometry with batchwise operation for hygienisation of liquid sludge. The influence of the parameters such as the source-target geometry, strength of 60 Co sources in the irradiator, hygienisation dose and rheological and hydraulic characteristics of sewage sludge on the selection of the three critical factors viz. the pumping rate (P) required to maintain turbulent flow regime in the irradiation zone; the mininum re-circulation time (Tsub(m)) essential to achieve a certain degree of homogeneity of dose absorption in the fluid; and the irradiation time (Tsub(i)) required to impart the necessary dose for the desired hygienisation effect in the sludge has been discussed in detail and inter-relationships among these three factors have been worked out. The applicability of the relationships to a typical operating plant has also been elucidated. (author)

  7. Source Term Analysis of the Irradiated Graphite in the Core of HTR-10

    Directory of Open Access Journals (Sweden)

    Xuegang Liu

    2017-01-01

    Full Text Available The high temperature gas-cooled reactor (HTGR has potential utilization due to its featured characteristics such as inherent safety and wide diversity of utilization. One distinct difference between HTGR and traditional pressurized water reactor (PWR is the large inventory of graphite in the core acting as reflector, moderator, or structure materials. Some radionuclides will be generated in graphite during the period of irradiation, which play significant roles in reactor safety, environmental release, waste disposal, and so forth. Based on the actual operation of the 10 MW pebble bed high temperature gas-cooled reactor (HTR-10 in Tsinghua University, China, an experimental study on source term analysis of the irradiated graphite has been done. An irradiated graphite sphere was randomly collected from the core of HTR-10 as sample in this study. This paper focuses on the analytical procedure and the establishment of the analytical methodology, including the sample collection, graphite sample preparation, and analytical parameters. The results reveal that the Co-60, Cs-137, Eu-152, and Eu-154 are the major γ contributors, while H-3 and C-14 are the dominating β emitting nuclides in postirradiation graphite material of HTR-10. The distribution profiles of the above four nuclides are also presented.

  8. Nuclear irradiation parameters of beryllium under fusion, fission and IFMIF irradiation conditions

    International Nuclear Information System (INIS)

    Fischer, U.; Chen, Y.; Leichtle, D.; Simakov, S.; Moeslang, A.; Vladimirov, P.

    2004-01-01

    A computational analysis is presented of the nuclear irradiation parameters for Beryllium under irradiation in typical neutron environments of fission and fusion reactors, and of the presently designed intense fusion neutron source IFMIF. The analysis shows that dpa and Tritium production rates at fusion relevant levels can be achieved with existing high flux fission reactors while the achievable Helium production is too low. The resulting He-Tritium and He/dpa ratios do not meet typical fusion irradiation conditions. Irradiation simulations in the medium flux test modules of the IFMIF neutron source facility were shown to be more suitable to match fusion typical irradiation conditions. To achieve sufficiently high production rates it is suggested to remove the creep-fatigue testing machine together with the W spectra shifter plate and move the tritium release module upstream towards the high flux test module. (author)

  9. The bronchiolar epithelium as a prominent source of pro-inflammatory cytokines after lung irradiation

    International Nuclear Information System (INIS)

    Ruebe, Claudia E.; Uthe, Daniela; Wilfert, Falk; Ludwig, Daniela; Yang Kunyu; Koenig, Jochem; Palm, Jan; Schuck, Andreas; Willich, Normann; Remberger, Klaus; Ruebe, Christian

    2005-01-01

    Purpose: To study in detail the temporal and spatial release of the pro-inflammatory cytokines tumor necrosis factor α, interleukin (IL)-1α, and IL-6 in the lung tissue of C57BL/6 mice after thoracic irradiation with 12 Gy. Methods and Materials: C57BL/6J mice were exposed to either sham irradiation or a single fraction of 12 Gy delivered to the thorax. Treated and sham-irradiated control mice were killed at 0.5 h, 1 h, 3 h, 6 h, 12 h, 24 h, 48 h, 72 h, 1 week, 2 weeks, 4 weeks, 8 weeks, 16 weeks, and 24 weeks post-irradiation (p.i.). Real-time multiplex reverse transcriptase polymerase chain reaction was established to evaluate the relative messenger RNA (mRNA) expression of TNF-α, IL-1α, and IL-6 in the lung tissue of the mice (compared with nonirradiated lung tissue). Immunohistochemical detection methods (alkaline phosphatase anti-alkaline phosphatase, avidin-biotin-complex [ABC]) and automated image analysis were used to quantify the protein expression of TNF-α, IL-1α, and IL-6 in the lung tissue (percentage of the positively stained area). Results: Radiation-induced release of the pro-inflammatory cytokines TNF-α, IL-1α, and IL-6 in the lung tissue was detectable within the first hours after thoracic irradiation. We observed statistically significant up-regulations for TNF-α at 1 h p.i. on mRNA (4.99 ± 1.60) and at 6 h p.i. on protein level (7.23% ± 1.67%), for IL-1α at 6 h p.i. on mRNA (11.03 ± 0.77) and at 12 h p.i. on protein level (27.58% ± 11.06%), for IL-6 at 6 h p.i. on mRNA (6.0 ± 3.76) and at 12 h p.i. on protein level (7.12% ± 1.93%). With immunohistochemistry, we could clearly demonstrate that the bronchiolar epithelium is the most prominent source of these inflammatory cytokines in the first hours after lung irradiation. During the stage of acute pneumonitis, the bronchiolar epithelium, as well as inflammatory cells in the lung interstitium, produced high amounts of TNF-α (with the maximal value at 4 weeks p.i.: 9.47% ± 1

  10. Development of an apparatus for measuring the thermal conductivity of irradiated or non-irradiated graphite; Realisation d'un appareil de mesure de la conductibilite thermique du graphite irradie ou non irradie

    Energy Technology Data Exchange (ETDEWEB)

    Bocquet, M; Micaud, G

    1962-07-01

    An apparatus was developed for measuring the thermal conductivity coefficient K of irradiated or non-irradiated graphite. The measurement of K at around room temperature with an accuracy of about 6% is possible. The study specimen is placed in a vacuum between a hot and a cold source which create a temperature gradient {delta}{theta}/ {delta}x in the steady state. The amount of heat transferred, Q, is deduced from the electrical power dissipated at the hot source, after allowing for heat losses. The thermal conductivity coefficient is defined as: K = Q/S. {delta}x/{delta}{theta}, S being the cross section of the sample. Systematic studies have made it possible to determine the mean values of the thermal conductivity. (authors) [French] Un appareil de mesure du coefficient de conductibilite thermique K du graphite irradie ou non irradie a ete realise. Utilisant le principe du transfert de chaleur, il permet de mesurer K au voisinage de la temperature ambiante avec une precision de 6 pour cent environ. L'echantillon de graphite etudie est place sous vide entre une source chaude et une source froide qui creent en regime permanent un gradient de temperature {delta}{theta}/{delta}x La quantite de chaleur transferee Q est deduite de la puissance electrique dissipee dans la source chaude en deduisant les pertes thermiques. Le coefficient de conductibilite thermique est defini par: K = Q/S. {delta}x/{delta}{theta} S designant la section de l'echantillon. Des etudes systematiques ont permis de determiner pour differents graphites non irradies les valeurs moyennes des coefficients de conductibilite thermique. Ces etudes ont mis en evidence pour un type de graphite donne, l'influence de la densite apparente sur le coefficient de conductibilite thermique. A partir de mesures effectuees sur des echantillons de graphite irradies preleves par carottage dans les empilements des reacteurs a moderateur de graphite les variations du rapport K0/Ki en fonction de la dose et de la

  11. Development of an irradiation system for a small size continuous run multipurpose gamma irradiator

    International Nuclear Information System (INIS)

    Calvo, Wilson Aparecido Parejo

    2005-01-01

    The Radiation Technology Center from Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Brazil, developed with a revolutionary design and national technology, a small size continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotate door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m 2 of floor area, the irradiator design is product overlap sources and the maximum capacity of cobalt-60 wet sources is 37 P Bq (1 MCi). The performed quantification program of this multipurpose irradiator was based on AAMI/ISO 11137 standard, which recommends the inclusion of the following elements: installation and process quantification. The initial load of the multipurpose irradiator was 3.4 P Bq (92.1 k Ci) with 13 cobalt-60 sources model C-188, supplied by MDS Nordion Ion Technologies - Canada. For irradiator dose optimization, the source distribution was done using the software Cadgamma developed by IPEN-CNEN/SP. The poly-methylmethacrylate (PMMA) dosimeters system, certified by the International Dose Assurance Service (IDAS) of the International Atomic Energy Agency (IAEA) was used for irradiator dose mapping. The economic analysis, performance concerning to dose uniformity and cobalt-60 utilization efficiency were calculated and compared with other commercial gamma

  12. Determination of 2-alkylcyclobutanones in ultraviolet light-irradiated fatty acids, triglycerides, corn oil, and pork samples: Identifying a new source of 2-alkylcyclobutanones.

    Science.gov (United States)

    Meng, Xiangpeng; Chan, Wan

    2017-02-15

    Previous studies have established that 2-alkylcyclobutanones (2-ACBs) are unique radiolytic products in lipid-containing foods that could only be formed through exposure to ionizing radiation, but not by any other means of physical/heat treatment methods. Therefore, 2-ACBs are currently the marker molecules required by the European Committee for Standardization to be used to identify foods irradiated with ionizing irradiation. Using a spectrum of state-of-the-art analytical instruments, we present in this study for the first time that the generation of 2-ACBs was also possible when fatty acids and triglycerides are exposed to a non-ionizing, short-wavelength ultraviolet (UV-C) light source. An irradiation dosage-dependent formation of 2-ACBs was also observed in UV-C irradiated fatty acids, triglycerides, corn oil, and pork samples. With UV-C irradiation becoming an increasingly common food treatment procedure, it is anticipated that the results from this study will alert food scientists and regulatory officials to a potential new source for 2-ACBs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Metodika tvorby a využití případových studií ve výuce a formou Open Educational Resources (OER

    Directory of Open Access Journals (Sweden)

    Jana Dlouhá

    2016-04-01

    Full Text Available Předložená metodika tvorby regionálních případových studií (PS udržitelného rozvoje pro vysokoškolské vzdělávání má za úkol ukázat, jakým způsobem lze ve výuce využít konkrétní případy z praxe a současně jak rozvíjet výzkumné nástroje relevantní pro místní environmentální problematiku a otázky udržitelného rozvoje území; důraz je přitom kladen na regionální kontext a specifika. Publikace výsledků formou otevřených vzdělávacích zdrojů (tzv. Open Educational Resources, OER umožní využít tyto materiály pro regionálně orientované školství i na nižších stupních vzdělávacího systému, pro prezentaci regionálních zvláštností, a může sloužit též pro podporu dialogu o rozvoji území mezi různými společenskými aktéry.

  14. An elevator for cobalt-60 source

    International Nuclear Information System (INIS)

    Tang Zaimin; Liang Donghu

    1990-07-01

    The elevator used for cobalt-60 source is a key device in the irradiation industry. It plays an important role in the safety and control of irradiation operation as well as the utilization rate of radiation source. From 1983 to 1986, Beijing Institute of Nuclear Engineering undertook designing of various size irradiation projects for different uses. Since then a kind of cobalt-60 source elevator suited for the irradiator of wet-source-storage has been chosen. It is reliable in the operation and complete in the function. An automatic control circuit brings the systems of cobalt-60 source elevator into an interlock system which ensures the irradiation operation safety. Besides introducing the structural features and performance of this elevator, the conditions of safety interlocking in raising or lowering the cobalt-60 source is also discussed. The discussion is from the safety viewpoint of operating an irradiator and irradiation technology

  15. The IMO-1 mobile irradiation unit

    International Nuclear Information System (INIS)

    Cancio, Ruben; Gomez, Aristobulo; Mugliaroli, Hugo.

    1976-07-01

    The IMO-I is made up by a gamma irradiation bucket and a fixed source, mounted on a trailer specially designed. This equipment has been completed with a radiocomunication device. The irradiator unit consist of two fixed and one movable body. The irradiation bucket has a volume of 30 x 40 x 30 cm and is moved through an hydraulic system with allows its vertical movement between the upper or charging position and the bottom or irradiation position. The telecontrol device has been installed in the room contiguous to the irradiator. The conventional industrial sources of Co 60 , are vertically located in stainless steel source holders at the botton fixed body and they can be changed according with the desired geometry. The trailer has been built over a plain chassis assembled structure with a double axle at the rear. It consists of two rooms, one for the irradiator machine and the other one for the telecontrol device and the radiocomunication facility. (author) [es

  16. Tensile mechanical properties of a stainless steel irradiated up to 19 dpa in the Swiss spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Shigeru, E-mail: saito.shigeru@jaea.go.jp [JAEA, J-PARC Center, Tokai-mura, Ibaraki-ken 319-1195 (Japan); Kikuchi, Kenji [Ibaraki Univ., iFRC, Tokai-mura, Ibaraki-ken 319-1106 (Japan); Hamaguchi, Dai [JAEA, J-PARC Center, Tokai-mura, Ibaraki-ken 319-1195 (Japan); Usami, Kouji; Endo, Shinya; Ono, Katsuto; Matsui, Hiroki [JAEA, Dept. of Hot Laboratories, Tokai-mura, Ibaraki-ken 319-1195 (Japan); Kawai, Masayoshi [KEK, Tsukuba-shi, Ibaraki-ken 305-0801 (Japan); Dai, Yong [PSI, Spallation Source Division, Villigen PSI (Switzerland)

    2012-12-15

    To evaluate the lifetime of the beam window of an accelerator-driven transmutation system (ADS), post irradiation examination (PIE) of the STIP (SINQ target irradiation program, SINQ; Swiss spallation neutron source) specimens was carried out. The specimens tested in this study were made from the austenitic steel Japan primary candidate alloy (JPCA). The specimens were irradiated at SINQ Target 4 (STIP-II) with high-energy protons and spallation neutrons. The irradiation conditions were as follows: the proton energy was 580 MeV, irradiation temperatures ranged from 100 to 430 Degree-Sign C, and displacement damage levels ranged from 7.1 to 19.5 dpa. Tensile tests were performed in air at room temperature (RT), 250 Degree-Sign C and 350 Degree-Sign C. Fracture surface observation after the tests was done by Scanning electron microscope (SEM). Results of the tensile tests performed at R.T. showed the extra hardening of JPCA at higher dose compared to the fission neutron irradiated data. At the higher temperatures, 250 Degree-Sign C and 350 Degree-Sign C, the extra hardening was not observed. Degradation of ductility bottomed around 10 dpa, and specimens kept their ductility until 19.5 dpa. All specimens fractured in ductile manner.

  17. Gemstone enhancing dedicated gamma irradiator development

    International Nuclear Information System (INIS)

    Omi, Nelson Minoru

    2006-01-01

    The gemstones gamma irradiation process to enhance the color is widely accepted for the jewelry industry. These gems are processed in conventional industrial gamma irradiation plant which are optimized for other purposes, using underwater irradiation devices with high rejection rate due to it's poor dose uniformity. A new conception design, which states the working principles and manufacturing ways of the device, was developed in this work. The suggested device's design is based on the rotation of cylindrical baskets and their translation in circular paths inside and outside a cylindrical source rack as a planetary system. The device is meant to perform the irradiation in the bottom of the source storage pool, where the sources remain always shielded by the water layer. The irradiator matches the Category III IAEA classification. To verify the physical viability of the basic principle, tests with rotating cylindrical baskets were performed in the Multipurpose Irradiator raised in the CTR, IPEN. Also, simulations using the CADGAMMA software, adapted to simulate underwater irradiations were performed. With the definitive irradiator, the irradiation quality will be enhanced with better dose control and the production costs will be significantly lower than market prices due to the intended treatment device's optimization. (author)

  18. Economics of gamma irradiation processing

    International Nuclear Information System (INIS)

    Tani, Toshio

    1980-01-01

    The gamma-ray irradiation business started at the Takasaki Laboratory of Japan Atomic Energy Research Institute. The irradiation facilities were constructed thereafter at various sites. The facilities must accept various types of irradiation, and must be constructed as multi-purpose facilities. The cost of irradiation consists of the cost of gamma sources, construction expense, personnel expense, management expense, and bank interest. Most of the expenses are considered to be fixed expense, and the amount of irradiation treatment decides the original costs of work. The relation between the irradiation dose and the construction expense shows the larger facility is more economical. The increase of amount of treatment reduces the original cost. The utilization efficiency becomes important when the amount of treatment and the source intensity exceed some values. The principal subjects of gamma-ray irradiation business are the sterilization of medical tools and foods for aseptic animals, the improvement of quality of plastic goods, and the irradiation of foods. Among them, the most important subject is the sterilization of medical tools. The cost of gamma irradiation per m 3 in still more expensive than that by ethylene oxide gas sterilization. However, the demand of gamma-ray irradiation is increasing. For the improvement of quality of plastic goods, electron irradiation is more favourable than the gamma irradiation. In near future, the economical balance of gamma irradiation can be achieved. (Kato, T.)

  19. Storage container of radium source newly manufactured for trial for intracavitary irradiation of cancer of the uterine cervix, 2

    International Nuclear Information System (INIS)

    Yamamoto, Chiaki; Sasaki, Tsuneo; Tanaka, Yoshiaki

    1977-01-01

    To decrease exposure dose from radium source to operators during the treatment of cancer of the uterine cervix, new-type storage container was manufactured and its usefullness was discussed. The new-type container manufactured for trial houses radium source, for intracavitary irradiation of cancer of the cervix, connecting with TAO-type applicator for afterloading. TLD 1200 Type was used for measurement of radiation dose, and radium 50 mCi was used per one case. The obtained results were as follows: Using the new-type container, 45-60% decrease of exposure dose in the hands and fingers and 44% decrease in the body were obtained. The exposure dose of persons engaged in work of radiotherapy for one week was only 2.2% of the maximum permissible exposure dose, The time treating radium source was shortened to 50% by using the new-type container, and the shortening of that time was a great factor of countermeasures for decreasing exposure dose to operators. From above-mentioned results, the new-type storage container can be put sufficiently to practical use as a storage container of radium source for intracavitary irradiation of cancer of the cervix (when using TAO type afterloading method). (Tsunoda, M.)

  20. Facts about food irradiation: Safety of irradiation facilities

    International Nuclear Information System (INIS)

    1991-01-01

    This fact sheet considers the safety of industrial irradiation facilities. Although there have been accidents, none of them has endangered public health or environmental safety, and the radiation processing industry is considered to have a very good safety record. Gamma irradiators do not produce radioactive waste, and the radiation sources at the facilities cannot explode nor in any other way release radioactivity into the environment. 3 refs

  1. Irradiation treatment of sewage sludge: History and prospects

    International Nuclear Information System (INIS)

    Bao Borong; Wu Minghong; Zhou Ruimin; Zhu Jinliang

    1998-01-01

    This paper first reviews the history of irradiation treatment of sewage sludge in the world. The first sludge irradiation plant was built in Geiselbullach, West Germany in 1973 and used 60 Co as irradiation source. Since then, many sludge irradiators were constructed in U.S.A., India, Japan, Canada, Poland, etc., which used 60 Co, 137 Cs or electron beam as irradiation sources. The paper then describes some basic research on irradiation treatment of sewage sludge including optimization of irradiation parameters, synergistic effect of radiation with heat, oxygenation, irradiation-composting and potential applications of treated sludge. Some proposals have been suggested for further development of this technology in the future

  2. Vinca irradiator

    International Nuclear Information System (INIS)

    Eymery, R.

    1976-10-01

    The development programme of the VINCA radiosterilisation centre involves plans for an irradiator capable of working in several ways. Discontinuous operation. The irradiator is loaded for a certain period then runs automatically until the moment of unloading. This method is suitable as long as the treatment capacity is relatively small. Continuous operation with permanent batch loading and unloading carried out either manually or automatically (by means of equipment to be installed later). Otherwise the design of the apparatus is highly conventional. The source is a vertical panel submersible in a pool. The conveyor is of the 'bucket' type, with 4 tiers to each bucket. The batches pass successively through all possible irradiation positions. Transfert into and out of the cell take place through a maze, which also provides access to the cell when the sources are in storage at the bottom of the pool [fr

  3. DOE uses transportable irradiator for demonstration and testing

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    The U.S. Dept. of Energy's Pacific Northwest Laboratory (PNL), Richland, Washington (operated by Battelle Memorial Institute), has a transportable irradiator that was built to travel to various locations to demonstrate the benefits of low-dose irradiation for the processing of food. Part of a DOE program designed to establish irradiation facilities in Alaska, Florida, Hawaii, Iowa, Oklahoma, and Washington, the mobile unit can also be used for research, pilot-scale processing, operator training, and education. The irradiation unit consists of two lead-lined cylindrical chambers-an irradiation chamber and a source chamber-inside a steel casing. During operation, the item to be irradiated is placed inside the irradiation chamber, which is then rotated until a window in the chamber lines up with a screened window in the source chamber. The source chamber contains the transportation cask containing the four capsules of cesium-137 that are used as the source of gamma radiation. During operation, the lid of the cask is raised, pulling the capsules into operating position. In this alignment, the product is irradiated for a predetermined length of time. Then the lid of the cask is lowered and the irradiation chamber is rotated back to its original position for removal of the product

  4. Irradiation device

    International Nuclear Information System (INIS)

    Ransohoff, J.A.

    1984-01-01

    Carriers, after being loaded with product to be irradiated, are transported by an input-output conveyor system into an irradiation chamber where they are received in a horizontal arrangement on racks which may support different sizes and numbers of carriers. The racks are moved by a chamber conveyor system in an endless rectangular path about a radiation source. Packers shift the carriers on the racks to maintain nearest proximity to the radiation source. The carriers are shifted in position on each rack during successive rack cycles to produce even radiation exposure. The carriers may be loaded singly onto successive racks during a first cycle of movement thereof about the source, with loading of additional carriers, and/or unloading of carriers, onto each rack occurring on subsequent rack cycles of movement

  5. Food irradiation

    International Nuclear Information System (INIS)

    Paganini, M.C.

    1991-06-01

    Food treatment by means of ionizing energy, or irradiation, is an innovative method for its preservation. In order to treat important volumes of food, it is necessary to have industrial irradiation installations. The effect of radiations on food is analyzed in the present special work and a calculus scheme for an Irradiation Plant is proposed, discussing different aspects related to its project and design: ionizing radiation sources, adequate civil work, security and auxiliary systems to the installations, dosimetric methods and financing evaluation methods of the project. Finally, the conceptual design and calculus of an irradiation industrial plant of tubercles is made, based on the actual needs of a specific agricultural zone of our country. (Author) [es

  6. Portable gamma-irradiator - a modified model

    International Nuclear Information System (INIS)

    Pandev, I.N.; Christova, M.G.; Stefanov, S.D.; Gentchev, N.V.; Bakardjiev, S.T.; Christov, C.D.; Genov, D.T.

    1983-01-01

    A new modification of a portable gamma-irradiator has been designed with a relatively large irradiation volume, good homogeneity of the gamma field, small overall dimension, light biological shielding, and simple mechanics. It is possible to irradiate materials in two cylindrical volumes (3 l and 6 l) with different dose rates. 137 Cs is used as a radiation source. Depending on application, the irradiator can be charged with various total activities up to 6.66 x 10 14 Bq (18 kCi). The dose rate can be also charged up to the maximum by different positions of the source element. The gamma-irradiator can be used for scientific studies and for industrial purposes. (author)

  7. Irradiation as a quarantine treatment

    International Nuclear Information System (INIS)

    Burditt, A.K. Jr.

    1991-01-01

    The use of irradiation as an alternative treatment for commodities subject to infestation by pests of quarantine importance is outlined in this article. A dose of 300 Gy or less has been found to prevent adult emergence when insect eggs or larvae are irradiated and research has shown that such doses will not affect the quality of most commodities. The use of gamma rays from cobalt-60 or caesium-137 sources, as well as electrons or X-rays from linear accelerators, has been approved for food irradiation. Irradiation facilities must meet regulations promulgated by nuclear, health and agricultural quarantine agencies with regard to location, facility design, sources, operation, personnel, dosimetry and other requirements. Education of industry operators and the general public is needed in order to gain acceptance of irradiation as a quarantine treatment. (author). 21 refs, 1 tab

  8. Relativistic radiative transfer in a moving stratus irradiated by a luminous flat source

    Science.gov (United States)

    Fukue, Jun

    2015-06-01

    Relativistic radiative transfer in a geometrically thin stratus (sheet-like gaseous cloud with finite optical depth), which is moving at a relativistic speed around a luminous flat source, such as accretion disks, and is irradiated by the source, is examined under the special relativistic treatment. Incident radiation is aberrated and Doppler-shifted when it is received by the stratus, and emitted radiation is also aberrated and Doppler-shifted when it leaves the stratus. Considering these relativistic effects, we analytically obtain the emergent intensity as well as other radiative quantities in the purely scattering case for both infinite and finite strati. We mainly consider the frequency-integrated case, but also briefly show the frequency-dependent one. We also solve the relativistic radiative transfer equation numerically, and compare the results with the analytical solutions. In the infinite stratus, the mean intensity in the comoving and inertial frames decreases and becomes constant, as the stratus speed increases. The flux in the comoving frame decreases exponentially with the optical depth. The emergent intensity decreases as the speed increases, since the incident photons are redshifted at the bottom-side of the stratus. In the finite stratus, the mean intensity in the comoving and inertial frames quickly increases in the top-side region due to the aberrated photons. The flux in the comoving frame is positive in the range of 0 negative for β ≳ 0.5. The behavior of the emergent intensity is similar to that of the infinite case, although there is an irradiation effect caused by the aberrated photons.

  9. General-purpose parallel algorithm based on CUDA for source pencils' deployment of large γ irradiator

    International Nuclear Information System (INIS)

    Yang Lei; Gong Xueyu; Wang Ling

    2013-01-01

    Combined with standard mathematical model for evaluating quality of deploying results, a new high-performance parallel algorithm for source pencils' deployment was obtained by using parallel plant growth simulation algorithm which was completely parallelized with CUDA execute model, and the corresponding code can run on GPU. Based on such work, several instances in various scales were used to test the new version of algorithm. The results show that, based on the advantage of old versions. the performance of new one is improved more than 500 times comparing with the CPU version, and also 30 times with the CPU plus GPU hybrid version. The computation time of new version is less than ten minutes for the irradiator of which the activity is less than 111 PBq. For a single GTX275 GPU, the maximum computing power of new version is no more than 167 PBq as well as the computation time is no more than 25 minutes, and for multiple GPUs, the power can be improved more. Overall, the new version of algorithm running on GPU can satisfy the requirement of source pencils' deployment of any domestic irradiator, and it is of high competitiveness. (authors)

  10. Foodstuff irradiation

    International Nuclear Information System (INIS)

    1982-01-01

    Report written on behalf of the Danish Food Institute summarizes national and international rules and developments within food irradiation technology, chemical changes in irradiated foodstuffs, microbiological and health-related aspects of irradiation and finally technological prospects of this conservation form. Food irradiatin has not been hitherto applied in Denmark. Radiation sources and secondary radiation doses in processed food are characterized. Chemical changes due to irradiation are compared to those due to p.ex. food heating. Toxicological and microbiological tests and their results give no unequivocal answer to the problem whether a foodstuff has been irradiated. The most likely application fields in Denmark are for low radiation dosis inhibition of germination, riping delay and insecticide. Medium dosis (1-10 kGy) can reduce bacteria number while high dosis (10-50 kGy) will enable total elimination of microorganisms and viruses. Food irradiation can be acceptable as technological possibility with reservation, that further studies follow. (EG)

  11. Dosimetry for Crystals Irradiation

    CERN Document Server

    Lecomte, Pierre

    2005-01-01

    Before shipment to CMS, all PbWO4 crystals produced in China are irradiated there with 60 Co , in order to insure that the induced absorption coefficient is within specifications. Acceptance tests at CERNand at ENEA also include irradiation with gamma rays from 60 Co sources. There were initially discrepancies in quoted doses and doserates as well as in induced absorption coefficients. The present work resolves the discrepancies in irradiation measurements and defines common dosimetry methods for consistency checks between irradiation facilities.

  12. Assessment of irradiated rice bran as iron source

    International Nuclear Information System (INIS)

    Wada, Heden Katsue

    2002-01-01

    Rice is the largest cereal crop in Brazil. To obtain the polish grain, its external peel is extracted after abrasive process. As a result, rice bran is obtained. It has low cost and high nutritional level, which has been include into malnourished children feeding. There is a considerable controversy related to the rice bran effect on the prevention and control of undernutrition and iron deficiency. The aim os this study was to assess the availability of in vitro iron of in natura and treated rice brans, after different levels of irradiation were applied. Both sorts of bran had their composition analyzed emphasizing the iron and phytate contents. The microbiological quality of the rice bran was also assessed. The pathogenic microorganisms were destroyed only in the in natura rice bran. As the irradiation level applied on the stabilized bran increased, its lipidic fraction reduced an the progressive destruction of the phytates occurred. The high iron content follow its availability in the rice bran, despite of the irradiation level applied, on the rice bran products and its dietetic preparations. (author)

  13. Reconstruction of Co-60 Irradiation Facility No.1

    International Nuclear Information System (INIS)

    Nakamura, Yoshiteru; Takada, Isao; Kaneko, Hirohisa; Hirao, Toshio; Haneda, Noriyuki; Mitomo, Shouichi; Tachibana, Hiroyuki; Yoshida, Kenzou

    1989-01-01

    Cobalt Irradiation Facility No.1 was constructed in 1964 as the first large scale Co-60 irradiation facility equipped a deep water pool for source storage of Co-60 sources. Recently, the reconstruction of the facility was decided because the aging of various parts of the facility became remarkable and new research programs required upgradings of the facility. Important points of upgradings are as follows: A shielding capacity of the source storage and pool is increased to 55.5 PBq from 18.5 PBq. The opening in a floor of the irradiation room which is used for the source lifting in the room, is enlarged in order to utilize a large and high intensity source. Radiation resistance of the irradiation apparatus and installed equipments in the radiation room is increased for a high dose rate irradiation. Basic structure and shape of the facility building such as shielding, pool and building roof is not changed but electrical, mechanical equipments and systems are completely renewed. To increase a reliability, the irradiation apparatus and systems are also replaced with an improved and up-to-date one designed based on operation experiences of Co-60 facilities at TRCRE through many years. In addition, auxiliary equipments such as radiation monitors, manipulators, water treatment system and so on are replaced. This report presents the reconstruction of Co-60 Irradiation Facility No.1 stressing on the replacement and modification of the irradiation apparatus. (author)

  14. SUPER-FMIT, an accelerator-based neutron source for fusion components irradiation testing

    International Nuclear Information System (INIS)

    Burke, R.J.; Holmes, J.J.; Johnson, D.L.; Mann, F.M.; Miles, R.R.

    1984-01-01

    The SUPER-FMIT facility is proposed as an advanced accelerator based neutron source for high flux irradiation testing of large-sized fusion reactor components. The facility would require only small extensions to existing accelerator and target technology originally developed for the Fusion Materials Irradiation Test (FMIT) facility. There, neutrons would be produced by a 0.1 ampere beam of 35 MeV deuterons incident upon a liquid lithium target. The volume available for high flux (> 10 14 n/cm 2 -s) testing in SUPER-FMIT would be 14 liters, about a factor of 30 larger than in the FMIT facility. This is because the effective beam current of 35 MeV deuterons on target can be increased by a factor of ten to 1.0 amperes or more. Such a large increase can be accomplished by acceleration of multiple beams of molecular deuterium ions (D 2 +) to 70 MeV in a common accelerator sructure. The availability of multiple beams and large total current allows great variety in the testing that can be done. For example, fluxes greater than 10 16 n/cm 2 -s, multiple simultaneous experiments, and great flexibility in tailoring of spatial distributions of flux and spectra can be achieved

  15. Radiation research of materials using irradiation capsules

    International Nuclear Information System (INIS)

    Chamrad, B.

    1976-01-01

    The methods are briefly characterized of radiation experiments on the WWR-S research reactor. The irradiation capsule installed in the reactor including the electronic instrumentation is described. Irradiated samples temperature is stabilized by an auxiliary heat source placed in the irradiation space. The electronic control equipment of the system is automated. In irradiation experiments, experimental and operating conditions are recorded by a digital measuring centre with electric typewriter and paper tape data recording and by an analog compensating recorder. The irradiation experiment control system controls irradiated sample temperature, the supply current size and the heating element temperature of the auxiliary stabilizing source, inert and technological pressures of the capsule atmosphere and the thermostat temperature of the thermocouple junctions. (O.K.)

  16. Fission product gamma-ray sources as an alternative to cobalt-60 sources for sewage sludge sterilization

    International Nuclear Information System (INIS)

    Herrnberger, V.R.D.

    1975-01-01

    The sterilization of sewage sludge is now performed successfully using 60 Co gamma-ray sources. The question arises whether more economic gamma-ray sources exist that could replace the 60 Co source. The following types of sources are considered: Spent fuel elements; mixtures of solidified fission products; and isolated solidified fission products such as 134 / 137 Cs. For a particular irradiation plant the specific source costs (S.Fr./Ci) and their contribution to the irradiation costs for 1 m 3 of sewage irradiated to a dose of 250 krad(S.Fr./m 3 ) are determined and compared with the costs of a plant using a 60 Co source. The encapsulation costs and the effect of the gamma absorption of the source are taken into account. Different encapsulation and source management techniques are reviewed to find the most economic for each source type. A spent fuel element irradiation facility is recommended for use either in combination with a sewage water purification plant or as part of a power reactor station where it replaces the storage water pool for the spent fuel elements. Additional source capsules are not envisaged, as long as double-walled source containers are used. The fission product mixtures are enclosed in double-walled capsules of two different forms: Small cylindrical rods and hollow cylinders. For caesium and cobalt cylindrical rods only are used. The main conclusions of the study are that the highest irradiation costs arise from the use of a fission product mixture source. The costs are, however, only 15% above those of a 60 Co plant. To be competitive the flow-rate has to be adapted to the decreasing activity of the source, resulting in a reduction to 20% within ten years of source utilization. The integrated irradiation plant with a spent fuel element source offers irradiation costs comparable with those of a 60 Co plant, if the flow-rate is constant during one year of source utilization. The irradiation costs are reduced to 25% of those of a 60 Co plant

  17. Facility for fast neutron irradiation tests of electronics at the ISIS spallation neutron source

    International Nuclear Information System (INIS)

    Andreani, C.; Pietropaolo, A.; Salsano, A.; Gorini, G.; Tardocchi, M.; Paccagnella, A.; Gerardin, S.; Frost, C. D.; Ansell, S.; Platt, S. P.

    2008-01-01

    The VESUVIO beam line at the ISIS spallation neutron source was set up for neutron irradiation tests in the neutron energy range above 10 MeV. The neutron flux and energy spectrum were shown, in benchmark activation measurements, to provide a neutron spectrum similar to the ambient one at sea level, but with an enhancement in intensity of a factor of 10 7 . Such conditions are suitable for accelerated testing of electronic components, as was demonstrated here by measurements of soft error rates in recent technology field programable gate arrays

  18. Characterization of the neutron irradiation system for use in the Low-Dose-Rate Irradiation Facility at Sandia National Laboratories.

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Manuel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-08-01

    The objective of this work was to characterize the neutron irradiation system consisting of americium-241 beryllium (241AmBe) neutron sources placed in a polyethylene shielding for use at Sandia National Laboratories (SNL) Low Dose Rate Irradiation Facility (LDRIF). With a total activity of 0.3 TBq (9 Ci), the source consisted of three recycled 241AmBe sources of different activities that had been combined into a single source. The source in its polyethylene shielding will be used in neutron irradiation testing of components. The characterization of the source-shielding system was necessary to evaluate the radiation environment for future experiments. Characterization of the source was also necessary because the documentation for the three component sources and their relative alignment within the Special Form Capsule (SFC) was inadequate. The system consisting of the source and shielding was modeled using Monte Carlo N-Particle transport code (MCNP). The model was validated by benchmarking it against measurements using multiple techniques. To characterize the radiation fields over the full spatial geometry of the irradiation system, it was necessary to use a number of instruments of varying sensitivities. First, the computed photon radiography assisted in determining orientation of the component sources. With the capsule properly oriented inside the shielding, the neutron spectra were measured using a variety of techniques. A N-probe Microspec and a neutron Bubble Dosimeter Spectrometer (BDS) set were used to characterize the neutron spectra/field in several locations. In the third technique, neutron foil activation was used to ascertain the neutron spectra. A high purity germanium (HPGe) detector was used to characterize the photon spectrum. The experimentally measured spectra and the MCNP results compared well. Once the MCNP model was validated to an adequate level of confidence, parametric analyses was performed on the model to optimize for potential

  19. Development of blood irradiators

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This project is designed to improve the techniques of blood irradiation through the development of improved and portable blood irradiators. A portable blood irradiator, consisting of a vitreous carbon body and thulium-170 radiation source, was attached to dogs via a carotid-jugular shunt, and its effects on the immune system measured. The device has demonstrated both significant suppression of circulating lymphocytes and prolonged retention of skin allografts

  20. Szilard-Chalmers effect in solid H I O{sub 4}. 2 H{sub 2} O by neutron irradiation (source-reactor)

    Energy Technology Data Exchange (ETDEWEB)

    Takriti, S [radiochemistry laboratory, syrian atomic energy commission P.O. Box 6091 Damascus, (Syrian Arab Republic)

    1995-10-01

    The Szilard-Chalmers effect in solid periodic acid was investigated. In order to study the initial distribution of {sup 128I} o{sub 4} as a function of neutron flux, samples were irradiated utilizing both neutron source ({sup 241} Am-Be), the manual vertical irradiation channel and the thermal column of ET-R R-1 research reactor in Egypt. The initial retention reached a maximum of 40% after 120 minutes at 5.5 x 10 {sup 8} n s{sup -1} cm {sup -2}. The data was analysed using first order reaction. As a result, the activation Ko= 2.82 x 10 {sup 11} (S{sup -1}), respectively. Kinetics comparison of the dehydration and irradiation reactions for this solid showed disorder in the crystallographic form. Such disorder may be the result of dehydration or irradiation reactions, where the loss of water molecule will lead to formation of vacancies which, in turn, are responsible for the distribution process. 6 figs., 1 tab.

  1. Non-destructive diagnostics of irradiated materials using neutron scattering from pulsed neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Korenev, Sergey E-mail: sergey_korenev@steris.com; Sikolenko, Vadim

    2004-10-01

    The advantage of neutron-scattering studies as compared to the standard X-ray technique is the high penetration of neutrons that allow us to study volume effects. The high resolution of instrumentation on the basis neutron scattering allows measurement of the parameters of lattice structure with high precision. We suggest the use of neutron scattering from pulsed neutron sources for analysis of materials irradiated with pulsed high current electron and ion beams. The results of preliminary tests using this method for Ni foils that have been studied by neutron diffraction at the IBR-2 (Pulsed Fast Reactor at Joint Institute for Nuclear Research) are presented.

  2. Non-destructive diagnostics of irradiated materials using neutron scattering from pulsed neutron sources

    Science.gov (United States)

    Korenev, Sergey; Sikolenko, Vadim

    2004-09-01

    The advantage of neutron-scattering studies as compared to the standard X-ray technique is the high penetration of neutrons that allow us to study volume effects. The high resolution of instrumentation on the basis neutron scattering allows measurement of the parameters of lattice structure with high precision. We suggest the use of neutron scattering from pulsed neutron sources for analysis of materials irradiated with pulsed high current electron and ion beams. The results of preliminary tests using this method for Ni foils that have been studied by neutron diffraction at the IBR-2 (Pulsed Fast Reactor at Joint Institute for Nuclear Research) are presented.

  3. Simulation of a high energy neutron irradiation facility at beamline 11 of the China Spallation Neutron Source

    Energy Technology Data Exchange (ETDEWEB)

    Tairan, Liang [School of Physics and Electronic Information Inner Mongolia University for the Nationalities, Tongliao 028043 (China); Zhiduo, Li [Dongguan Branch, Institute of High Energy Physics, CAS, Beijing 100049 (China); Wen, Yin, E-mail: wenyin@aphy.iphy.ac.cn [Dongguan Branch, Institute of High Energy Physics, CAS, Beijing 100049 (China); Institute of Physics, CAS, P.O. Box 603, Beijing 100190 (China); Fei, Shen [Dongguan Branch, Institute of High Energy Physics, CAS, Beijing 100049 (China); Quanzhi, Yu [Dongguan Branch, Institute of High Energy Physics, CAS, Beijing 100049 (China); Institute of Physics, CAS, P.O. Box 603, Beijing 100190 (China); Tianjiao, Liang [Dongguan Branch, Institute of High Energy Physics, CAS, Beijing 100049 (China)

    2017-07-11

    The China Spallation Neutron Source (CSNS) will accommodate 20 neutron beamlines at its first target station. These beamlines serve different purposes, and beamline 11 is designed to analyze the degraded models and damage mechanisms, such as Single Event Effects in electronic components and devices for aerospace electronic systems. This paper gives a preliminary discussion on the scheme of a high energy neutron irradiation experiment at the beamline 11 shutter based on the Monte Carlo simulation method. The neutron source term is generated by calculating the neutrons scattering into beamline 11 with a model that includes the target-moderator-reflector area. Then, the neutron spectrum at the sample position is obtained. The intensity of neutrons with energy of hundreds of MeV is approximately 1E8 neutron/cm{sup 2}/s, which is useful for experiments. The displacement production rate and gas productions are calculated for common materials such as tungsten, tantalum and SS316. The results indicate that the experiment can provide irradiation dose rate ranges from 1E-5 to 1E-4 dpa per operating year. The residual radioactivity is also calculated for regular maintenance work. These results give the basic reference for the experimental design.

  4. Automation of gamwave batch irradiator in Natal, South Africa

    International Nuclear Information System (INIS)

    Basson, J.K.; Basson, R.A.; Botha, J.

    1995-01-01

    High Energy Processing (HEPRO) has operated a Nordion JS 8200 Batch Irradiator for several years at Gamwave in Durban, South Africa. Product is loaded into aluminium totes and manually transported on trolleys into the irradiation chamber. Unirradiated totes are then exchanged with all the irradiated totes in the product pass mechanism, after which the source is raised and the batch irradiation process is started. Due to the inefficient Cobalt utilization experienced in this type of plant, it was decided to upgrade and automate the facility. This was done in what we believe is a simple and unique solution to the problem facing the future of such batch facilities. The design concept used for the Gamwave irradiator was based on irradiating product in carbons or bags of variable dimensions as per customer requirements. The intention was to convey product automatically in and out of the irradiation chamber eliminating the product change over downtime and thereby increasing source up utilization. Minor extensions were carried out to the Bioshield with the existing irradiator in full operation awaiting installation of the new source pass mechanism and conveyor system. Total plant shutdown for conversion to automation, including source reload and safety checks, was estimated to take ten days to fit the equipment. (author)

  5. Review of events at large pool-type irradiators

    International Nuclear Information System (INIS)

    Trager, E.A. Jr.

    1989-03-01

    Large pool-type gamma irradiators are used in applications such as the ''cold'' sterilization of medical and pharmaceutical supplies, and recent changes in federal regulations make it possible they will be used extensively in the preservation of foodstuffs. Because of this possible large increase in the use of irradiators, the Office of Nuclear Materials Safety and Safeguards was interested in knowing what events had occurred at irradiators. The event data would be used as background in developing new regulations on irradiators. Therefore, AEOD began a study of the operating experience at large, wet source storage gamma irradiators. The scope of the study was to assess all available operating information on large (≥ 250,000 curie), pool-type irradiators licensed by both the NRC and the Agreement States, and events at foreign facilities. The study found that about 0.12 events have been reported per irradiator-year. Most of these events were precursor events, in that there was no evidence of damage to the radioactive sources or degradation in the level of safety of the facility. Events with more significant impacts had a reported frequency of about 0.01 event per irradiator-year. However, the actual rate of occurrence of events of concern to the staff may be higher because there are few specific reporting requirements for events at irradiators. It is suggested that during development of a regulation for large pool-type irradiators consideration be given to specifying requirements for: reporting breakdowns in access control systems; periodic inspection of the source movement and suspension system; systems to detect source leakage and product contamination; allowable pool leakage; and feedback of information on operational events involving safety-important systems

  6. Changes of lipids in irradiated chickens

    International Nuclear Information System (INIS)

    Moersel, J.T.; Wende, I.; Schwarz, K.

    1991-01-01

    Chickens were irradiated in a 6 deg Co gamma irradiation source. The irradiation has been done to reduce or eliminate Salmonella. The experiments were done to test this decontamination method of chickens if changes of lipids take place. It was to be seen, that peroxidation of lipids was more rapidly as in control. The time of storage of irradiated chickens has to be shorter because of changes in lipids. After irradiation the chickens had trade quality. (orig.) [de

  7. Dose uniformity estimations in the blood irradiator

    International Nuclear Information System (INIS)

    George, J.R.

    2002-01-01

    Use of irradiated blood in transfusions is recognized as the most effective way of preventing Graft Versus Host Disease (GVHD). This paper shows the study carried out in the dose rate variation for various source arrangements for optimising the source-sample chamber geometry, during the development of the Blood Irradiator, Bl-2000

  8. X-ray photoelectron microscope with a compact x-ray source generated by line-focused laser irradiation

    International Nuclear Information System (INIS)

    Yamaguchi, N.; Okamoto, Y.; Hara, T.; Takahashi, Z.; Nishimura, Y.; Sakata, A.; Watanabe, K.; Azuma, H.

    2004-01-01

    Full text: A laboratory-sized microscopic system of x-ray photoelectrons has been developing using a compact x-ray source produced by line-focused laser irradiation. The system is a scanning type photoelectron microscope where x-ray beam is micro-focused via a Schwartzschild optics. A compact laser-plasma x-ray source has been developed with a YAG laser system, a line-focus lens system, a tape-target driving system and a debris prevention system, that was operated at repetition rate of 10 Hz or 50 Hz. X-rays were delivered along line plasma whose length was 0.6 to 11 mm with higher intensity than that from a point-focused source. Because the transition line of Al V (13.1 nm) was prominent in the soft x-ray spectrum when the Al tape target irradiated at the lower power density of 10 11 W/cm 2 , the 13.1 nm x-ray was used as an excitation source. The Schwartzschild optics was set on the beamline at a distance about 1 m from the source, which was coated with Mo/Si multilayers for 13.1 nm x-ray. The designed demagnification is 224 that was confirmed in the previous experiment. Therefore, an x-ray micro spot of sub-micron size can be formed on a sample surface when the source size is less than about 0.2 mm. Samples were set on a two-axis high-precision piezo stage mounted to a four-axis manipulator. The electron energy analyzer was a spherical capacitor analyzer with mean diameter of 279.4 mm. The electron detector was a microchannel plate (MCP) with a phosphor screen and the optical image of electrons on the exit plane of the analyzer was taken and recorded by using an ultra low dark noise CCD camera, that was suited for detection of vast photoelectrons excited by x-ray pulse of ns-order duration. We performed spatial resolution test measurements by using a GaAs wafer coated with photo-resist that formed a stripe pattern. The spatial resolution less than 3 micron has been obtained from the variation of As 3d electron intensity along the position of the GaAs sample

  9. Tissue irradiator

    International Nuclear Information System (INIS)

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

    1975-01-01

    A tissue irradiator is provided for the in-vivo irradiation of body tissue. The irradiator comprises a radiation source material contained and completely encapsulated within vitreous carbon. An embodiment for use as an in-vivo blood irradiator comprises a cylindrical body having an axial bore therethrough. A radioisotope is contained within a first portion of vitreous carbon cylindrically surrounding the axial bore, and a containment portion of vitreous carbon surrounds the radioisotope containing portion, the two portions of vitreous carbon being integrally formed as a single unit. Connecting means are provided at each end of the cylindrical body to permit connections to blood-carrying vessels and to provide for passage of blood through the bore. In a preferred embodiment, the radioisotope is thulium-170 which is present in the irradiator in the form of thulium oxide. A method of producing the preferred blood irradiator is also provided, whereby nonradioactive thulium-169 is dispersed within a polyfurfuryl alcohol resin which is carbonized and fired to form the integral vitreous carbon body and the device is activated by neutron bombardment of the thulium-169 to produce the beta-emitting thulium-170

  10. Microstructure and mechanical properties of neutron irradiated OFHC-copper before and after post-irradiation annealing

    DEFF Research Database (Denmark)

    Singh, B.N.; Edwards, D.J.; Toft, P.

    2001-01-01

    of recovery depends on the irradiation dose level. However, the post-irradiation annealing eliminates theproblem of yield drop and reinstates enough uniform elongation to render the material useful again. These results are discussed in terms of the cascade induced source hardening (CISH) and the dispersed...

  11. Electron accelerator technology research in food irradiation

    International Nuclear Information System (INIS)

    Jin Jianqiao; Ye Mingyang; Zhang Yue; Yang Bin; Xu Tao; Kong Xiangshan

    2014-01-01

    Electronic accelerator was applied to instead of cobalt sources for food irradiation, to keep food quality and to improve the effect of the treatment. Appropriate accelerator parameters lead to optimal technique. The irradiation effect is associated with the relationship between uniformity and irradiating speed, the effect of cargo size on radiation penetration, as well as other factors that affect the irradiation effects. Industrialization of electron accelerator irradiation will be looked to the future. (authors)

  12. Food package irradiator-a landmark of operational safety and food irradiation research

    International Nuclear Information System (INIS)

    Jain, M.P.; Sanyal, Bhaskar; Ghosh, Sunil K.

    2017-01-01

    Food irradiation in India has been undertaken for preservation of food for safe consumption, security of food for round the year and export of the food commodities to earn foreign exchange. Therefore, an irradiation plant known as Food Package Irradiator (FPI) was set-up in the year 1967 in BARC. This plant utilizes gamma radiation from "6"0Co source that has a maximum allowable activity of 100 kCi. It is a multipurpose facility where a wide range of products like onion for sprout inhibition to spices for microbial decontamination can be carried out. In short, the design of irradiator has been considered based on obtaining variable throughputs and variable dose rates

  13. Lack of appetite for food irradiation

    International Nuclear Information System (INIS)

    Tacey, Elisabeth

    1989-01-01

    The British government has approved food irradiation in Britain on a much wider scale than has taken place previously. The implications for one of the companies currently offering a gamma irradiation service are explored. Irradiation is by a large Cobalt 60 source. Currently the customers are medical, cosmetic and packaging firms. It does not yet have the facilities necessary for large-scale food irradiation, nor does it expect a huge demand for food irradiation as customer resistance is strong. However some dry spices and herbs may be treated next year. (UK)

  14. Techno-economic studies on transportable moving-bed onion irradiator

    International Nuclear Information System (INIS)

    Krishnamurthy, K.; Sharma, K.S.S.; Deshmukh, V.P.; Bongirwar, D.R.; Nair, K.V.V.; Patil, K.B.

    1984-01-01

    The paper presents the optimisation studies and the design features of a transportable irradiator evolved to demonstrate the techno-economic advantage of the irradiation process at village level. A brief outline is also given of the computer programme generated and employed to optimise the source-target configuration based on a narrow plane source moving-bed irradiation concept that aimed at achieving a simplified product handling system and cost effective design of the biological shield and controls for the irradiator. The engineering features of the irradiator along with a summary of the analysis of the economics of the application of the process are also given. (author)

  15. Design of special facility for liquor irradiation

    International Nuclear Information System (INIS)

    Yao Shibin; Chen Zigen

    1989-01-01

    The design principle, physical scheme, technological process, construction and safety features of a special facility used for irradiating liquors is briefly described. 0.925 x 10 15 Bq cobalt source is used and the irradiation capacity for liquors approaches 10 t per day. The facility bears advantages of simple in construction, easy to operate, safe, reliable and efficient in source utilization

  16. New multipurpose gamma-irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, G

    1985-01-01

    In the past 3 years much work has been done in the G.D.R. on food irradiation. The experiments have shown that this treatment gives favourable results in many products such as spices, onions, potatoes, chicken, animal feeds, fodder yeast, drugs and vaccines. Economic aspects of food irradiation require the effective use of an irradiation plant and cobalt-60. Therefore, a new multipurpose irradiation facility was developed, applicable as an onion irradiator with a capacity of about 15 ton/h and for the simultaneous irradiation of different products (spices, animal feed, chicken, etc.) in closed product boxes with a size of 1.2 m x 1.0 m x 1.2 m. A microcomputer controls the transport of product boxes around the gamma sources.

  17. Irradiation-Induced Nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Birtcher, R.C.; Ewing, R.C.; Matzke, Hj.; Meldrum, A.; Newcomer, P.P.; Wang, L.M.; Wang, S.X.; Weber, W.J.

    1999-08-09

    This paper summarizes the results of the studies of the irradiation-induced formation of nanostructures, where the injected interstitials from the source of irradiation are not major components of the nanophase. This phenomena has been observed by in situ transmission electron microscopy (TEM) in a number of intermetallic compounds and ceramics during high-energy electron or ion irradiations when the ions completely penetrate through the specimen. Beginning with single crystals, electron or ion irradiation in a certain temperature range may result in nanostructures composed of amorphous domains and nanocrystals with either the original composition and crystal structure or new nanophases formed by decomposition of the target material. The phenomenon has also been observed in natural materials which have suffered irradiation from the decay of constituent radioactive elements and in nuclear reactor fuels which have been irradiated by fission neutrons and other fission products. The mechanisms involved in the process of this nanophase formation are discussed in terms of the evolution of displacement cascades, radiation-induced defect accumulation, radiation-induced segregation and phase decomposition, as well as the competition between irradiation-induced amorphization and recrystallization.

  18. Cobalt-60 total body irradiation dosimetry at 220 cm source-axis distance

    International Nuclear Information System (INIS)

    Glasgow, G.P.; Mill, W.B.

    1980-01-01

    Adults with acute leukemia are treated with cyclophosphamide and total body irradiation (TBI) followed by autologous marrow transplants. For TBI, patients seated in a stand angled 45 0 above the floor are treated for about 2 hours at 220 cm source-axis distance (SAD) with sequential right and left lateral 87 cm x 87 cm fields to a 900 rad mid-pelvic dose at about 8 rad/min using a 5000 Ci cobalt unit. Maximum (lateral) to minimum (mid-plane) dose ratios are: hips--1.15, shoulders--1.30, and head--1.05, which is shielded by a compensator filter. Organ doses are small intestine, liver and kidneys--1100 rad, lung--1100 to 1200 rad, and heart--1300 rad. Verification dosimetry reveals the prescribed dose is delivered to within +-5%. Details of the dosimetry of this treatment are presented

  19. Irradiations at RTNS-II

    International Nuclear Information System (INIS)

    Heikkinen, D.W.; Logan, C.M.

    1982-01-01

    The RTNS-II 14-MeV neutron source facility at Lawrence Livermore National Laboratory is described. Average neutron source parameters are outlined. A brief general description of the irradiation program to the present time is given. A short discussion of guidelines for prospective users is also given

  20. How to improve the irradiation conditions for the International Fusion Materials Irradiation Facility

    CERN Document Server

    Daum, E

    2000-01-01

    The accelerator-based intense D-Li neutron source International Fusion Materials Irradiation Facility (IFMIF) provides very suitable irradiation conditions for fusion materials development with the attractive option of accelerated irradiations. Investigations show that a neutron moderator made of tungsten and placed in the IFMIF test cell can further improve the irradiation conditions. The moderator softens the IFMIF neutron spectrum by enhancing the fraction of low energy neutrons. For displacement damage, the ratio of point defects to cascades is more DEMO relevant and for tritium production in Li-based breeding ceramic materials it leads to a preferred production via the sup 6 Li(n,t) sup 4 He channel as it occurs in a DEMO breeding blanket.

  1. An overview of food irradiation

    International Nuclear Information System (INIS)

    Stevenson, M.H.

    1991-01-01

    This outline survey reviews the subject of food irradiation under the following headings:- brief history, the process (sources, main features of a food processing facility, interaction of radiation with food, main applications of the technology, packaging) consumer concerns (safety, nutritional changes, labelling, detection), international use of food irradiation and legal aspects. (UK)

  2. Infrared Irradiation: Toward Green Chemistry, a Review.

    Science.gov (United States)

    Escobedo, René; Miranda, René; Martínez, Joel

    2016-03-26

    This review provides a comprehensive overview of where infrared irradiation has been employed, mainly as regards activating green mode for natural products extractions, as well as to favor a reaction, highlighting its actual importance. It is also underlined that infrared irradiation heating has been around for a long time; however, only in the last eighteen years have many of its advantages been applied to satisfy a wide range of chemical processes, natural products extractions, and for the promotion of many kinds of reactions. In addition, it is brought to light that near infrared irradiation is more efficient than middle and far infrared irradiations, being easily controllable and with the quality of a fast responding heat source. Thus, the main objective of this review is to offer infrared irradiation as an alternative clean energy source to activate reactions, in addition to favor the selective extraction of natural products, all of which is within the Green Chemistry protocol. Some recent results from our laboratory are also included.

  3. The irradiation tolerance dose of the proximal vagina

    International Nuclear Information System (INIS)

    Au, Samuel P.; Grigsby, Perry W.

    2003-01-01

    Purpose: The purpose of this investigation was to determine the irradiation tolerance level and complication rates of the proximal vagina to combined external irradiation and low dose rate (LDR) brachytherapy. Also, the mucosal tolerance for fractionated high dose rate (HDR) brachytherapy is further projected based on the biological equivalent dose (BED) of LDR for an acceptable complication rate. Materials and methods: Two hundred seventy-four patients with stages I-IV cervical carcinoma treated with irradiation therapy alone from 1987 to 1997 were retrospectively reviewed for radiation-associated late sequelae of the proximal vagina. All patients received LDR brachytherapy and 95% also received external pelvic irradiation. Follow-up ranged from 15 to 126 months (median, 43 months). The proximal vagina mucosa dose from a single ovoid (single source) or from both ovoids plus the tandem (all sources), together with the external irradiation dose, were used to derive the probability of a complication using the maximum likelihood logistic regression technique. The BED based on the linear-quadratic model was used to compute the corresponding tolerance levels for LDR or HDR brachytherapy. Results: Grades 1 and 2 complications occurred in 10.6% of patients and Grade 3 complications occurred in 3.6%. There were no Grade 4 complications. Complications occurred from 3 to 71 months (median, 7 months) after completion of irradiation, with over 60% occurring in the first year. By logistic regression analysis, both the mucosal dose from a single ovoid or that from all sources, combined with the external irradiation dose, demonstrate a statistically significant fit to the dose response complication curves (both with P=0.016). The single source dose was highly correlated with the all source dose with a cross-correlation coefficient 0.93. The all source dose was approximately 1.4 times the single source dose. Over the LDR brachytherapy dose rate range, the complication rate was

  4. Study on the improvement of irradiation process

    International Nuclear Information System (INIS)

    Jin, Joon Ha; Yoon, Byung Mok; Kim, Ki Yup; Nho, Young Chang; Lee, Young Keun; Park, Soon Chul; Na, Bong Joo; Yoo, Young Soo

    1993-02-01

    The source operation system, carrier systems, safety systems and all other miscellaneous systems were installed for the High Intensity Co-60 Gamma Irradiation Facility. The Co-60 Source(72,800 Ci) was installed on the source rack by Canadian engineers and the facility was approved to be safe after some test operations. The acceleration tube, transformer, main control panel and high voltage cable were installed in the Electron Accelerator Facility. All parts of the accelerator were inspected and repaired. The Low Intensity Co-60 Gamma Irradiator in Seoul was dismantled for moving to Taejon and source operation and safety systems were prepared for the new facility. During the installations, old parts and equipments of each irradiation facility were replaced and many improvement were made on the systems by installing the irradiation tables and experimental holes, movements of control and machine room and ventilation fans to each reasonable position, and installation of additional fire alarm system and cable terminal box. The knowledge and experiences obtained during the installations will be very helpful for the operation and maintenance of the facilities in the future. The facilities will be utilized for the various researches and application fields such as polymer, food agriculture, biology, equipment qualification, etc. (Author)

  5. Research to connect the ozone monitor into irradiation system at Hanoi Irradiation Centre

    International Nuclear Information System (INIS)

    Le Van Huy; Pham Duy Duong; Nguyen Dinh Hung; Vu Quoc Dat

    2013-01-01

    Since 2006, in order to develop radiation technology, Vietnam Atomic Energy Institute has supported Hanoi Irradiation Centre a Project titled: Upgrading the irradiation facility. According to the Project, equipment have been replaced by a new one so that the facility could be suitable for treatment of products. The facility was designed and produced by the former Russia experts. Under normal operating conditions, we are protected by shielding, detection systems, and safety procedures. A system of interlocks prevents unauthorized entry into the radiation chamber when the source is exposed. However, interlocks system have not been warning and preventing ozone gas that can affect human health. So we are having an upgrade as connecting the ozone monitor into irradiation system at Hanoi Irradiation Centre. (author)

  6. Flux and energy deposition distribution studies inside the irradiation room of the portuguese 60Co irradiation facility

    International Nuclear Information System (INIS)

    Portugal, Luis; Oliveira, Carlos

    2008-01-01

    Full text: In December 2003 the irradiator of the Portuguese 60 Co irradiation facility, UTR, was replenished. Eighteen new sources were loaded and the older ones (156) were rearranged. The result was an irradiator with about 10.2 P Bq of total activity. The active area of the irradiator has also increased. Now it uses twenty five of the thirty tubes of the source rack, nine more than in the previous geometry. This facility was designed mainly for sterilisation of medical devices. However it is also used for the irradiation of other products such as cork stoppers, plastics and a limited number of food and feed. The purpose of this work is to perform dosimetric studies inside the irradiation room of a 60 Co irradiation facility, particularly, the flux and energy deposition distributions. The MCNPX code was used for the simulation of the facility. The track average mesh tally capabilities of MCNPX were used to plot the photon flux and energy deposition distributions. This tool provides a fast way for flux and energy deposition mapping. The absorbed dose distribution near the walls of the irradiation room was also calculated. Instead of using meshtallys as before, the average absorbed dose inside boxes lined with the walls was determined and afterwards a plot of its distribution was made. The absorbed dose rates obtained ranged from 5 to 500 Gy.h -1 depending on material being irradiated in process and the location on the wall. These positions can be useful for fixed irradiation purposes. Both dosimetric studies were done considering two different materials being irradiated in the process: cork stoppers and water, materials with quite different densities (0.102 and 1 g.cm-3, respectively). These studies showed some important characteristics of the radiation fields inside the irradiation room, namely its spatial heterogeneity. Tunnelling and shadow effects were enhanced when the product boxes increases its density. Besides a deeper dosimetric understanding of the

  7. X-ray irradiation of yeast cells

    Science.gov (United States)

    Masini, Alessandra; Batani, Dimitri; Previdi, Fabio; Conti, Aldo; Pisani, Francesca; Botto, Cesare; Bortolotto, Fulvia; Torsiello, Flavia; Turcu, I. C. Edmond; Allott, Ric M.; Lisi, Nicola; Milani, Marziale; Costato, Michele; Pozzi, Achille; Koenig, Michel

    1997-10-01

    Saccharomyces Cerevisiae yeast cells were irradiated using the soft X-ray laser-plasma source at Rutherford Laboratory. The aim was to produce a selective damage of enzyme metabolic activity at the wall and membrane level (responsible for fermentation) without interfering with respiration (taking place in mitochondria) and with nuclear and DNA activity. The source was calibrated by PIN diodes and X-ray spectrometers. Teflon stripes were chosen as targets for the UV laser, emitting X-rays at about 0.9 keV, characterized by a very large decay exponent in biological matter. X-ray doses to the different cell compartments were calculated following a Lambert-Bouguet-Beer law. After irradiation, the selective damage to metabolic activity at the membrane level was measured by monitoring CO2 production with pressure silicon detectors. Preliminary results gave evidence of pressure reduction for irradiated samples and non-linear response to doses. Also metabolic oscillations were evidenced in cell suspensions and it was shown that X-ray irradiation changed the oscillation frequency.

  8. Is food irradiation an alternative to chemical preservation?

    International Nuclear Information System (INIS)

    Horacek, P.

    1987-01-01

    The history is presented of food irradiation. The foods irradiated and the doses used are reported. The industrial use of food irradiation is restricted to a single industrial irradiation plant in Japan and several small facilities for irradiating herbs and feeds for special laboratory animal breeds. The limited application of the method is caused by high prices of radiation sources and adverse side effects (potato rotting, bad smell of meat, etc.). (M.D.). 1 fig., 1 tab

  9. Building lab-scale x-ray tube based irradiators

    International Nuclear Information System (INIS)

    Haff, Ron; Jackson, Eric; Gomez, Joseph; Light, Doug; Follett, Peter; Simmons, Greg; Higbee, Brad

    2016-01-01

    Here we report the use of x-ray tube based irradiators as alternatives to gamma sources for laboratory scale irradiation. Irradiators were designed with sample placement in closest possible proximity to the source, allowing high dose rates for small samples. Designs using 1000 W x-ray tubes in single tube, double tube, and four tube configurations are described, as well as various cabinet construction techniques. Relatively high dose rates were achieved for small samples, demonstrating feasibility for laboratory based irradiators for research purposes. Dose rates of 9.76, 5.45, and 1.7 Gy/min/tube were measured at the center of a 12.7 cm container of instant rice at 100 keV, 70 keV, and 40 keV, respectively. Dose uniformity varies dramatically as the distance from source to container. For 2.54 cm diameter sample containers containing adult Navel Orangeworm, dose rates of 50–60 Gy/min were measured in the four tube system. - Highlights: • X-ray is demonstrated as an alternative to gamma for lab-based irradiation. • Cabinets using one, two, and four 1000 W tubes are reported. • Dose rate of 9.8 Gy/min/tube at the center of a 12.7 cm container of instant rice. • Dose uniformity varies dramatically as the distance from source to container.

  10. Needs of in-situ materials testing under neutron irradiation

    International Nuclear Information System (INIS)

    Noda, K.; Hishinuma, A.; Kiuchi, K.

    1989-01-01

    Under neutron irradiation, the component atoms of materials are displaced as primary knock-on atoms, and the energy of the primary knock-on atoms is consumed by electron excitation and nuclear collision. Elementary irradiation defects accumulate to form damage structure including voids and bubbles. In situ test under neutron irradiation is necessary for investigating into the effect of irradiation on creep behavior, the electric properties of ceramics, transport phenomena and so on. The in situ test is also important to investigate into the phenomena related to the chemical reaction with environment during irradiation. Accelerator type high energy neutron sources are preferable to fission reactors. In this paper, the needs and the research items of in situ test under neutron irradiation using a D-Li stripping type high energy neutron source on metallic and ceramic materials are described. Creep behavior is one of the most important mechanical properties, and depends strongly on irradiation environment, also it is closely related to microstructure. Irradiation affects the electric conductibity of ceramics and also their creep behavior. In this way, in situ test is necessary. (K.I.)

  11. Electrochemical methods for identification of irradiated liquid foods

    International Nuclear Information System (INIS)

    Xie Zongchuan; Ma Li; Shi Shuangping

    1988-01-01

    Samples of 14 kinds of wine, soy, vinegar, spirits, fruits in syrup, etc.were exposed to a Co-60 source. They responded with changes in electric potential and conductance. Especially, the electric potential in irradiated Shugan white spirits (made of sweet potato) was five times that in non-irradiated ones. Eighty five days after irradiation, the electric potential in the irradiated spirits dropped, but was still three times that in non- irradiated ones. The conductance in irradiated spirits was twenty percent more than that in non-irradiated ones. With addition of 0.1% H 2 O 2 to the spirits be- fore irradiation, the electric potential changed even larger

  12. Dosimetry of a gammabeam - 650 60Co irradiator. II. Mapping of isodose curves in the irradiation chamber

    International Nuclear Information System (INIS)

    Escobedo, J.F.; Nascimento Filho, V.F. do; Ferraz, E.S.B.

    1980-01-01

    On 1st April 1974 a map was made of the chamber at CENA containing the 650 Gammabeam 60 Co irradiator source with nominal activity of 29,080 curies, using Fricke's dosimeter. The isodose curves were determined for the geometry of 10 cm diameter between 12 active tubes and proved to be symetric around the irradiator. Additionally, three mathematical models (linear source, three point source and point source) were developed for a theoretical estimate of the exposure rates, which were in many cases less than the rates experimentally determined. This difference was probably due to radiation scattering by shielding, sidewalls and the ceilling of the chamber, not being taken into consideration in the theoretical estimate. There was no significant difference in the exposure rates of the mathematical models and as the point source model is the simplest, its use is recommended. (Author) [pt

  13. Brachytherapy Partial Breast Irradiation: Analyzing Effect of Source Configurations on Dose Metrics Relevant to Toxicity

    International Nuclear Information System (INIS)

    Cormack, Robert A.; Devlin, Phillip M.

    2008-01-01

    Purpose: Recently, the use of partial breast irradiation (PBI) for patients with early-stage breast cancer with low-risk factors has increased. The volume of the high-dose regions has been correlated with toxicity in interstitial treatment. Although no such associations have been made in applicator-based experience, new applicators are being developed that use complex noncentered source configurations. This work studied the effect of noncentered source placements on the volume of the high-dose regions around a spherical applicator. Methods and Materials: Many applicator configurations were numerically simulated for a range of inflation radii. For each configuration, a dose homogeneity index was used as a dose metric to measure the volume of the high-dose region. Results: All multisource configurations examined resulted in an increase of the high-dose region compared with a single-center source. The resulting decrease in the prescription dose homogeneity index was more pronounced for sources further from the center of the applicator, and the effect was reduced as the number of dwell locations was increased. Conclusion: The geometries of particular applicators were not considered to achieve a more general result. On the basis of the calculations of this work, it would appear that treatment using noncentered dwell locations will lead to an increase in the volume of the high-dose regions

  14. Effects of irradiation on minerals and their consequences in geo-chronology

    International Nuclear Information System (INIS)

    Seydoux-Guillaume, Anne-Magali

    2011-01-01

    In this HDR (accreditation to supervise research studies) report, the author first gives a brief overview of her scientific approach. Then, addressing the irradiation of minerals by a radioactive source, she discusses the effects of irradiation, notably in the case of monazite, reports an experimental approach of external irradiation by ion beams, and comments some side effects like irradiation of host minerals. She also comments how irradiation-induced damages interfere with some processes like diffusion kinetics and dissolution. She addresses the case of mineral irradiation by means of a femto-second laser source: scientific approach, effects on mineral microstructure, notably in the case of monazite and quartz. The last part discusses issues in abeyance and perspectives in the field of irradiation textures, consequences on the geo-chronological response, alteration mechanisms, role of defects, and contribution of experimental irradiation

  15. Food irradiation dispelling the doubts

    International Nuclear Information System (INIS)

    Nair, P.M.

    1994-01-01

    Irradiation processing of the food item eliminates the use of harmful chemicals for treatment of food items and the produce can be conserved fresh. Another important aspect of this process is that it can help to stabilize the prices and give better remuneration to the farmer and hygienic product to the consumer. The already growing Indian nuclear industry can provide the source as well as the pros and cons of food technology for installation of irradiation facilities. The pros and cons of irradiation process are described. (M.K.V.)

  16. Chronic blood irradiation: a new approach

    International Nuclear Information System (INIS)

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.; Gillis, M.F.

    1976-01-01

    Extracorporeal irradiation of blood is beneficial in suppressing early rejection of renal allografts and in treating chronic lymphocytic leukemia. Previously, nearly all blood irradiation has involved brief intermittent exposures with high dose rates. The small amount of data available involving chronic irradiation suggests that doses given chronically at lower rates are more effective in suppressing graft rejection. However, no suitably portable device has been available to permit chronic irradiation. This work has been directed toward developing a fully portable irradiator. After preliminary testing of a variety of source materials, 170 Tm was selected for its favorable beta energy, low cost, and compatibility with the fabrication requirements. The body of the irradiator is cast from polyfurfuryl alcohol with subsequent high-temperature conversion to vitreous carbon. By sequential layering of the alcohol and suspending of 169 Tm 2 O 3 in the midlayer, a unit is produced without any radiation exposure and with the source material contained on both a macro and a micro scale. Exposure of the unit to reactor neutrons produces 170 Tm without activation of the vitreous carbon. A 170 Tm irradiator giving a transit dose of 16 rads (100 ml/min flow) was connected in a carotid--jugular shunt on a 20-kg goat. Lymphocyte levels decreased to about 15 percent of the preexposure level during the first week and thereafter slowly rose to about 50 percent of preexposure levels 2 months after exposure. Reciprocal skin grafts made at the end of irradiation (12 days) were rejected at 12 days on the nonirradiated control and at 24 days on the irradiated goat. These results are consistent with data reported on chronically irradiated baboons even though the dose rate for the present test was only about one-fourth that for the baboons

  17. Kraft cooking of gamma irradiated wood, (1). Effect of alcohol additives on pre-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, M; Meshitsuka, G; Nakano, J [Tokyo Univ. (Japan). Faculty of Agriculture

    1979-12-01

    Studies have been made of kraft cooking of gamma irradiated wood. Beech (Fagus crenata Blume) wood meal suspended in aqueous alkaline alcohol was irradiated up to 1.5 KGy (0.15 Mrad) with gamma rays from a Co-60 source in the presence or absence of oxygen. The irradiated wood meals were washed thoroughly with fresh water, air dried and cooked under the ordinary cooking conditions. The results are summarized as follows: (1) Pre-irradiation in aqueous alkali have negligible effect on kraft cooking. (2) In the case of ethanol addition (50 g/l), pre-irradiation in vacuo shows acceleration of delignification and stabilization of carbohydrates during kraft cooking. Cooked yield gain by pre-irradiation was about 1.2 in all, over the range of delignification from 80 to 90%. Aqueous ethanol without alkali also shows positive but smaller effect than that with alkali. (3) Propanol, iso-propanol and butanol show positive but smaller effects than ethanol. However, methanol does not show any positive effect. (4) Irradiation in the presence of oxygen does not show any attractive effect on kraft cooking.

  18. Safety analysis of a pool Genesis II irradiator

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de A.

    2011-01-01

    The Genesis II Irradiator manufactured by GRAT * STAR Inc. (USA) is a category III gamma irradiator in which the sealed source is contained in a water filled storage pool and is shielded permanently, i.e. the material has to move down to the source. Even though the pool is 5.6 m deep, what would happen if the water level lowered? There are a series of safety devices that will avoid this situation and calculations show that the water level has to be very low in order to deliver a significant dose; moreover, only in case a person remains at the border of the pool for a long time this would be risky. In conclusion, it is practically impossible for someone to be exposed to radiation from a Genesis II Irradiator source. (author)

  19. Shipboard-irradiation of haddock

    International Nuclear Information System (INIS)

    Ehlermann, D.; Reinacher, E.; Antonacopoulos, N.

    1977-01-01

    Haddock caught during the 183rd and 185th voyage of the RV 'Anton Dohrn' off Faeroeer was gutted, washed and packed under vacuum in polyethylene pouches. The samples were irradiated with the onboard X-ray source. During one series of experiments a minimum dose of 65 krad and a maximum dose of 130 krad was used. During further series the minimal dose was set to 100 krad, resulting in maximum values of 140 krad and 180 krad. As judged by taste panel evaluation of steam-cooked, unseasoned filets, quality preservation of all samples during the first 16 days of iced storage did not depend on irradiation. After that period the fish had lost prime quality. At this time, irradiated samples were rated slightly better than unirradiated ones. Base on our results, the shipboard-irradiation of prepacked haddock cannot be recommended. This does not exclude that under different conditions (e.g. fishfilets in retail packages) beneficial effects of irradiation may be observed. (orig.) [de

  20. Shipboard-irradiation of haddock

    International Nuclear Information System (INIS)

    Ehlermann, D.; Reinacher, E.; Antonacopoulos, N.

    1977-01-01

    Haddock caught during the 183rd and 185th voyage of the RV 'Anton Dohrn' off Faeroer was gutted, washed and packed under vacuum in polythylene pouches. The samples were irradiated with the onboard X-ray source. During one series of experiments a minimum dose of 65 krad and a maximum dose of 130 krad was used. During further series the minimal dose was set to 100 krad, resulting in maximum values of 140 krad and 180 krad. As judged by taste panel evalution of steam-cooked, unseasoned filets, quality preservation of all samples during the first 16 days of iced storage did not depend on irradiation. After that period the fish had lost prime quality. At this time, irradiated samples were rated slightly better than unirradiated ones. On the basis of these results, the shipboard-irradiation of prepacked haddock cannot be recommended. This does not exclude that under different conditions (e.g. fishfilets in retail packages) beneficial effects of irradiation may be observed. (orig.) [de

  1. 10 CFR 36.35 - Source rack protection.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Source rack protection. 36.35 Section 36.35 Energy NUCLEAR... Requirements for Irradiators § 36.35 Source rack protection. If the product to be irradiated moves on a product conveyor system, the source rack and the mechanism that moves the rack must be protected by a barrier or...

  2. Effect of neutron irradiation and post-irradiation annealing on microstructure and mechanical properties of OFHC-copper

    International Nuclear Information System (INIS)

    Singh, B.N.; Edwards, D.J.; Toft, P.

    2001-01-01

    Specimens of oxygen-free high conductivity (OFHC) copper were irradiated in the DR-3 reactor at Risoe at 100 deg. C to doses in the range 0.01-0.3 dpa (NRT). Some of the specimens were tensile tested in the as-irradiated condition at 100 deg. C whereas others were given a post-irradiation annealing treatment at 300 deg. C for 50 h and subsequently tested at 100 deg. C. The microstructure of specimens was characterized in the as-irradiated as well as irradiated and annealed conditions both before and after tensile deformation. While the interstitial loop microstructure coarsens with irradiation dose, no significant changes were observed in the population of stacking fault tetrahedra (SFT). The post-irradiation annealing leads to only a partial recovery and the level of recovery depends on the irradiation dose level. However, the post-irradiation annealing eliminates the yield drop and reinstates enough uniform elongation to render the material useful again. These results are discussed in terms of the cascade-induced source hardening (CISH) model

  3. Effect of neutron irradiation and post-irradiation annealing on microstructure and mechanical properties of OFHC-copper

    Energy Technology Data Exchange (ETDEWEB)

    Singh, B.N. E-mail: bachu.singh@risoe.dk; Edwards, D.J.; Toft, P

    2001-12-01

    Specimens of oxygen-free high conductivity (OFHC) copper were irradiated in the DR-3 reactor at Risoe at 100 deg. C to doses in the range 0.01-0.3 dpa (NRT). Some of the specimens were tensile tested in the as-irradiated condition at 100 deg. C whereas others were given a post-irradiation annealing treatment at 300 deg. C for 50 h and subsequently tested at 100 deg. C. The microstructure of specimens was characterized in the as-irradiated as well as irradiated and annealed conditions both before and after tensile deformation. While the interstitial loop microstructure coarsens with irradiation dose, no significant changes were observed in the population of stacking fault tetrahedra (SFT). The post-irradiation annealing leads to only a partial recovery and the level of recovery depends on the irradiation dose level. However, the post-irradiation annealing eliminates the yield drop and reinstates enough uniform elongation to render the material useful again. These results are discussed in terms of the cascade-induced source hardening (CISH) model.

  4. Effect of neutron irradiation and post-irradiation annealing on microstructure and mechanical properties of OFHC-copper

    Science.gov (United States)

    Singh, B. N.; Edwards, D. J.; Toft, P.

    2001-12-01

    Specimens of oxygen-free high conductivity (OFHC) copper were irradiated in the DR-3 reactor at Risø at 100 °C to doses in the range 0.01-0.3 dpa (NRT). Some of the specimens were tensile tested in the as-irradiated condition at 100 °C whereas others were given a post-irradiation annealing treatment at 300 °C for 50 h and subsequently tested at 100 °C. The microstructure of specimens was characterized in the as-irradiated as well as irradiated and annealed conditions both before and after tensile deformation. While the interstitial loop microstructure coarsens with irradiation dose, no significant changes were observed in the population of stacking fault tetrahedra (SFT). The post-irradiation annealing leads to only a partial recovery and the level of recovery depends on the irradiation dose level. However, the post-irradiation annealing eliminates the yield drop and reinstates enough uniform elongation to render the material useful again. These results are discussed in terms of the cascade-induced source hardening (CISH) model.

  5. Study on the source of optical activity: Pt. 6. ESR spectroscopy on the asymmetrical radical yields in 90Sr-90Y β irradiated D-and L-alanine

    International Nuclear Information System (INIS)

    Wang Wenqing; Zhao Jian; Ding Xiang

    1993-01-01

    Free radical formation in 90 Sr- 90 Y β irradiated D- and L-alanine is studied by ESR spectroscopy. To calibrate the probable differences in the size of ESR tubes, the different densities of alanine and the incidental different impurities, samples are firstly irradiated with 60 Co γ rays. Then the D- and L- alanine samples are irradiated with 90 Sr- 90 Y source at 77 K. Soon after irradiation, ESR measurement is performed on each sample. The average ratio H β+γ /H γ of D- alanine is 0.147 higher than that of L- alanine, indicating that more free radicals are induced in D- alanine by β irradiation. Irradiation at 77 K is capable of diminishing the effect of thermal movement on the polarization of β electrons and freezing the free radical formation. The experiments show the stereoselective interaction of β electrons with D- and L- amino acids, and so supports the Vester-ulbricht hypothesis

  6. Computational dosimetry in the development of a category-III irradiator

    International Nuclear Information System (INIS)

    George, Jain R.; Parmar, Y.D.; Kohli, A.D.

    2008-01-01

    Full text: Preservation of food by radiation processing has been widely accepted and yielding tremendous industrial and societal benefits. It is a challenge to meet the vast range of dose requirements for the radiation processing of food items in the most economical way. The Board of Radiation and Isotope Technology, a unit of the Department of Atomic Energy, Government of India is developing a Co 60 irradiator of Category-III for the radiation processing of food commodities for commercial application. In this irradiator water is the only shielding material and unlike other irradiators this does not have any concrete or lead shielding above ground and no electrical interlock systems. The radiation source never leaves underwater shielded position. A computational method has been developed for the dose and throughput estimations which is used for the optimization of various parameters of this irradiator. Co 60 source pencils of total strength 18.5 P Bq arranged in two tiers in a rectangular source frame is considered ideal for this irradiator. Food items in the density range 0.15 x 10 3 kg.m -3 to 1.0 x 10 3 kg.m -3 were considered for processing. Product enclosed in a box of dimensions 1.2 m x 0.6 m x 1.2 m moves and occupies four positions around the source. The product is kept dry by proper leak tighteners. The double side irradiation provides a good dose distribution within the product. Parametric analysis has been carried out for various possible inactive gap lengths between the two tiers of the source and for various distances between the source and the product in order to optimize them for the acceptable dose uniformity within the product as well as for the best source utilization efficiency. This has been done for different density products. (author)

  7. Infrared Irradiation: Toward Green Chemistry, a Review

    Directory of Open Access Journals (Sweden)

    René Escobedo

    2016-03-01

    Full Text Available This review provides a comprehensive overview of where infrared irradiation has been employed, mainly as regards activating green mode for natural products extractions, as well as to favor a reaction, highlighting its actual importance. It is also underlined that infrared irradiation heating has been around for a long time; however, only in the last eighteen years have many of its advantages been applied to satisfy a wide range of chemical processes, natural products extractions, and for the promotion of many kinds of reactions. In addition, it is brought to light that near infrared irradiation is more efficient than middle and far infrared irradiations, being easily controllable and with the quality of a fast responding heat source. Thus, the main objective of this review is to offer infrared irradiation as an alternative clean energy source to activate reactions, in addition to favor the selective extraction of natural products, all of which is within the Green Chemistry protocol. Some recent results from our laboratory are also included.

  8. Fully portable blood irradiator

    International Nuclear Information System (INIS)

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

    1980-01-01

    A fully portable blood irradiator was developed using the beta emitter thulium-170 as the radiation source and vitreous carbon as the body of the irradiator, matrix for isotope encapsulation, and blood interface material. These units were placed in exteriorized arteriovenous shunts in goats, sheep, and dogs and the effects on circulating lymphocytes and on skin allograft retention times measured. The present work extends these studies by establishing baseline data for skin graft rejection times in untreated animals

  9. Comparison of material irradiation conditions for fusion, spallation, stripping and fission neutron sources

    International Nuclear Information System (INIS)

    Vladimirov, P.; Moeslang, A.

    2004-01-01

    Selection and development of materials capable of sustaining irradiation conditions expected for a future fusion power reactor remain a big challenge for material scientists. Design of other nuclear facilities either in support of the fusion materials testing program or for other scientific purposes presents a similar problem of irradiation resistant material development. The present study is devoted to an evaluation of the irradiation conditions for IFMIF, ESS, XADS, DEMO and typical fission reactors to provide a basis for comparison of the data obtained for different material investigation programs. The results obtained confirm that no facility, except IFMIF, could fit all user requirements imposed for a facility for simulation of the fusion irradiation conditions

  10. The Development of Gamma Irradiator Control System

    International Nuclear Information System (INIS)

    Mohd Zaid Hassan; Anwar Abdul Rahman; Azraf Azman; Mohd Rizal Mamat

    2015-01-01

    This paper presents the preliminary software development for the Gamma irradiator control system using commercial supervisory control and data acquisition (SCADA) software. The radiation dose analysis is the study of the relationship between the initial loading source activity (Curie) and concurrent activity in order to perform the irradiation process. The concurrent source activity calculation model is presented. The Human machine interface (HMI) has been developed by using Indusoft Web Studio to solve the mathematical calculation, task and process overview. (author)

  11. Studies on the method of producing radiographic 170Tm source

    International Nuclear Information System (INIS)

    Maeda, Sho

    1976-08-01

    A method of producing radiographic 170 Tm source has been studied, including target preparation, neutron irradiation, handling of the irradiated target in the hot cell and source capsules. On the basis of the results, practical 170 Tm radiographic sources (29 -- 49Ci, with pellets 3mm in diameter and 3mm long) were produced in trial by neutron irradiation with the JMTR. (auth.)

  12. 21 CFR 179.25 - General provisions for food irradiation.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true General provisions for food irradiation. 179.25... (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) IRRADIATION IN THE PRODUCTION, PROCESSING AND HANDLING OF FOOD Radiation and Radiation Sources § 179.25 General provisions for food irradiation. For the purposes...

  13. Pollen-gamma irradiation on pineapple and pollination using irradiated pollen

    International Nuclear Information System (INIS)

    Benega, R.; Cisneros, A.; Martinez, J.; Arias, E.; Yabor, L.; Isidron, M.; Castillo, E.; Fernandez, J.

    1997-01-01

    In order to try to induce haploid plants, pineapple (Ananas comosus (L.) ;err.) pollen grains were gamma-rays irradiated with a Co 60 source at rates of doses from 0 to 300 Gy. The effect of gamma-rays on the generative-nucleus division and vitro pollen viability as well as, seed contents and plantlets obtained after pollinations was analysed. The were reducing in the division frequencies of generative nucleus at all assayed doses. The LD50 was achieved among 200 and 250 Gy. There were not differences on pollen viability in the rates of assayed doses. Seed contents were dose-dependent. The percentages of seed full and seed containing only embryos decreases at increasing of irradiation doses. Contrary effect was observed on the seed empty. Some plantlets regenerated from the different irradiation doses showed phenotypes with small and leaves and short inter nodes

  14. Dose mapping in category I irradiators

    International Nuclear Information System (INIS)

    Mondal, Sandip; Shinde, S.H.; Mhatre, S.G.V.

    2012-01-01

    Category I irradiators such as Gamma Chambers and Blood Irradiators are compact self shielded, dry source storage gamma irradiators offering irradiation volume of few hundred cubic centimeters. In the present work, dose distribution profiles along the central vertical plane of the irradiation volume of Gamma Chamber 900 and Blood Irradiator 2000 were measured using Fricke, FBX, and alanine dosimeters. Measured dose distribution profiles in Gamma Chamber 900 differed from the typical generic dose distribution pattern whereas that in Blood Irradiator 2000 was in agreement with the typical pattern. All reagents used were of analytical reagent grade and were used without further purification. Preparation and dose estimations of Fricke and FBX were carried out as recommended. Alanine pellets were directly placed in precleaned polystyrene container having dimensions 6.5 mm o.d., 32 mm height and 3 mm wall thickness. For these dosimeters, dose measurements were made using e-scan Bruker BioSpin alanine dedicated ESR spectrometer. Specially designed perspex jigs were used during irradiation in Gamma Chamber 900 and Blood Irradiator 2000. These jigs provided the reproducible geometry during irradiation, Absorbance measurements were made using a spectrophotometer calibrated as per the recommended procedure. In Gamma Chamber 900, there is a dose distribution variation of about 34% from top to the center, 18% from center to the bottom, and 15% from center to the periphery. Such a dose distribution profile is largely deviating from the typical profile wherein 15% variation is observed from center to the periphery on all sides. Further investigation showed that there was a nonalignment in the source and sample chamber. However, in Blood Irradiator 2000, there is a dose distribution variation of about 20% from top to the center, 15% from center to the bottom, and 12% from center to the periphery. This pattern is very much similar to the typical profile. Hence it is recommended

  15. Food irradiation: contaminating our food

    International Nuclear Information System (INIS)

    Piccioni, R.

    1988-01-01

    The nuclear industry has promoted food irradiation as an effective and safe means of preserving food at minimum risk to the public. However, wide-scale food irradiation programmes such as that approved in the United States of America would have an adverse impact on public health in the following ways: through the consumption of carcinogenic substances generated in irradiated foods, through the use of irradiation to mask bacteriological contamination of spoiled food, through the replacement of fresh foods with nutritionally depleted foods, through accidents with leaks or mishandling of the radiation sources used and through the environmental damage resulting from reactor operation or spent fuel reprocessing necessary to produce the required isotopes for food irradiation. The food irradiation market is potentially enormous, requiring a large number of facilities and isotopes, some, such as caesium-137, would come from the production of nuclear weapons. Evidence of the presence of carcinogenic or mutagenic activity in irradiated foods is discussed. Although the US Federal Drug Administration (FDA) has approved a food irradiation programme it would actually be against the FDA's legal obligation which is to protect the health and safety of the American people. (UK)

  16. An apparatus for cattle-blood irradiation

    International Nuclear Information System (INIS)

    Damdinsuerehn, S.; Gunaadzav, T.; Chueltehm, D.; Sajnkhueue, Zh.; Byambaa, S.; Moenkhtsehtsehg, N.; Dorzhnyambuu, B.

    1989-01-01

    An apparatus for cattle-blood irradiation in vitro by low intensity ultraviolet light (10-12 w/m 2 ) emitted by mercury-quartz lamp at the wavelength range of 254-280 nm has been constructed. For this purpose a simple connection circuit for shunting the source electrodes by effective resistance and switching on electrical network in series through capacitor is presented. Stabilized cattle blood for UV-irradiation is running through 5mm diameter quartz tubes at the distance of 15mm from UV-lamp. Irradiated in this way blood sample is administered intravenously or intramuscular in various way. Method of using this source in veterinary practice is developed. Results of the use of this method during the last 4-5 years demonstrate the efficiency of treating and preventing from desease could be above 80%. 1 fig. (B.Sh.)

  17. Irradiation dose of cosmonauts

    International Nuclear Information System (INIS)

    Makra, Zs.

    1978-01-01

    The results obtained by determining the irradiation dose during the spaceflights of Apollo as well as the Sojouz-3 and Sojouz-9 spacecrafts have been compared in the form of tables. In case of Apollo astronauts the irradiation dose was determined by two methods and its sources were also pointed out, in tables. During Sojouz spacetravels the cosmonauts were exposed to a negligible dose. In spite of this fact the radiation danger is considerable. The small irradiation doses noticed so far are due to the fact that during the spaceflights there was no big proturberance. However, during the future long-range spacetravels a better radiation shielding than the one used up to now will be necessary. (P.J.)

  18. Irradiation: Technology whose time has come?

    International Nuclear Information System (INIS)

    Schechter, M.

    1985-01-01

    The characteristics and application of food irradiation are briefly discussed, noting FDA's recent approval of the use of this technology to kill trichnella spirals in pork. Despite public concerns, food irradiation sources (gamma rays from Co-60 and Cs-137) are reported to leave no radioactivity in irradiated foods when used under FDA-approved guidelines. Food irradiation was legally ruled to be a 'food additive' by Congress in 1958 with FDA having regulatory authority; however, while low-level dosing has received FDA approval for sprout inhibition in root crops and as an insect control, concerns about cost-effectiveness, safety, and consumer acceptability have continued to limit high dose food irradiation (i.e., exposure to over 1000krad). The future acceptance of food irradiation still, primarily rests in the hands of food service professionals and their consumers

  19. Sensitivity of Listeria monocytogenes to irradiation

    International Nuclear Information System (INIS)

    Tarjan, Veronika

    1990-01-01

    Irradiation of Listeria monocytogenes (L.m.) was carried out in culture media and pork meat paste at room temperature with 60 Co radiation source of 6.6 kGy h -1 dose rate. The employed doses were 0, 0.5, 1, 2, 3, 4 and 6 kGy. One strain out of 3 survived as high as 4 kGy irradiation. Radiation with 2 kGy resulted 7 log cycles reduction of cell count. After lower irradiation doses the L.m. count decreased in proportion to increasing doses. It has been concluded that L.m. compared with Gram-negative pathogens, are less sensitive to irradiation. (author) 6 refs.; 4 figs

  20. Transformation of 2,2′,4,4′-tetrabromodiphenyl ether under UV irradiation: Potential sources of the secondary pollutants

    International Nuclear Information System (INIS)

    Wang, Ji-Zhong; Hou, Yuqing; Zhang, Jianshun; Zhu, Jiping; Feng, Yong-Lai

    2013-01-01

    Highlights: • 2,2′,4,4′-Tetrabromodiphenyl ether (BDE-47) was found transformed to six less brominated BDE analogs under UV irradiation. • BDE-47 was found degraded faster in liquid phase than in gas phase. • Two brominated phenols were formed in the transformation of BDE-47 in gas phase. • The bromine on the ortho positions of the phenyl rings was found lost first to form 2,4,4′-tribromodiphenyl ether (BDE-28). • The more volatile less brominated BDEs are a source of secondary pollutants in the environment. -- Abstract: A commercial brominated flame retardant 2,2′,4,4′-tetrabromodiphenyl ether (BDE-47) was used as the model chemical to investigate the degradation and transformation of polybrominated diphenyl ethers (PBDEs) in gas and liquid phases, respectively, under ultraviolet (UV) irradiation. The results showed that BDE-47 can be transformed to less-brominated BDE analogs. A total of six compounds that are less-brominated BDEs and two brominated phenols were observed as transformation products in the reaction mixtures. Different degradation rates of BDE-47 in n-nonane and in isooctane in the same chamber system were observed. Degradation rate of BDE-47 in n-nonane was faster than in isooctane. Under UV irradiation, the bromine on the ortho positions of the phenyl rings was lost first to form 2,4,4′-tribromodiphenyl ether (BDE-28), which then progressively lead to 4,4′-dibromodiphenyl ether (BDE-15) or 2,4′-dibromodiphenyl ether (BDE-8). An airborne transformation pathway has been proposed according to observed transformation products. The more volatile less-brominated BDEs from transformation of BDE-47 are easily evaporated into air to be a source of secondary pollutants in the environment

  1. An upgrade practice of a double-rack source 60Co source irradiator

    International Nuclear Information System (INIS)

    Dong Hui; Peng Wei; Liu Zhaomin

    2009-01-01

    An upgrade practice of a double-rack irradiator with the design capacity of 2.96 x10 16 Bq (800 kCi) was reported. The detailed contents and characteristics of this upgrade, a comparison on the facility performance before and after the upgrade, and the cost-benefit analysis were carried out. After upgrade, the facility performance increased over 50%, and brought much directly economical benefit and indirectly economical benefit. The upgrade was successful, and set up a demonstrational sample. (authors)

  2. Design of Shanghai irradiation center

    International Nuclear Information System (INIS)

    Chen Fugen; Lu Zhongwen; Xue Xiangrong; Yao Zewu; Du Bende; Xu Zhicheng; Du Kangsen

    1988-01-01

    Shanghai Irradiation Center, situated in westrn suburb of Shanghai, was completed in August, 1986. At present, a 6.55 x 10 15 Bq 60 Co source has been loaded, though the designed activity of maximum loading is 18.5 x 10 10 Bq. the center is designed mainly for irradiation preservation of food and sterilization of medical devices and tools. Its processing ability is 10 t/h for potatoes

  3. Realization of double-pulse laser irradiating scheme for laser ion sources

    International Nuclear Information System (INIS)

    Li Zhangmin; Jin Qianyu; Liu Wei; Zhang Junjie; Sha Shan; Zhao Huanyu; Sun Liangting; Zhang Xuezhen; Zhao Hongwei

    2015-01-01

    A double-pulse laser irradiating scheme has been designed and established for the production of highly charged ion beams at Institute of Modern Physics (IMP), Chinese Academy of Sciences. The laser beam output by a Nd : YAG laser is split and combined by a double of beam splitters, between which the split laser beams are transmitted along different optical paths to get certain time delay between each other. With the help of a quarter-wave plate before the first splitter, the energy ratio between the two laser pulses can be adjusted between 3 : 8 to 8 : 3. To testify its feasibility, a preliminary experiment was carried out with the new-developed double-pulse irradiating scheme to produce highly charged carbon ions. Comparing the results with those got from the previous single-pulse irradiating scheme, the differences in the time structure and Charge State Distribution (CSD) of the ion pulse were observed, but its mechanisms and optimization require further studies. (authors)

  4. Microstructure and mechanical properties of neutron irradiated OFHC-copper before and after post-irradiation annealing

    International Nuclear Information System (INIS)

    Singh, B.N.; Edwards, D.J.; Toft, P.

    2001-02-01

    Tensile specimens of OFHC-copper were irradiated with fission neutrons in the DR-3 reactor at Risoe National Laboratory at 100 deg. C to different displacement dose levels in the range of 0.01 to 0.3 dpa (NRT). Some of the specimens were tensile tested in the as-irradiated condition at 100 deg. C whereas other were given a post-irradiation annealing at 300 deg. C for 50 h and subsequently tested at 100 deg. C. Transmission electron microscopy was used to characterize the microstructure of specimens in the as-irradiation as well as irradiation and annealed conditions both before and after tensile deformation. The results show that while the interstitial loop microstructure coarsens with irradiation dose, no significant changes are observed in the population of stacking fault tetrahedra. The results also illustrates that the post-irradiation annealing leads to only a partial recovery and that the level of recovery depends on the irradiation dose level. However, the post-irradiation annealing eliminates the problem of yield drop and reinstates enough uniform elongation to render the material useful again. These results are discussed in terms of the cascade induced source hardening (CISH) and the dispersed barrier hardening (DBH) models. Both technological and scientific implications of these results are considered. (au)

  5. Irradiation of spices - a review

    International Nuclear Information System (INIS)

    Sadecka, J.

    2007-01-01

    Food irradiation is a process of exposing food to ionising radiation such as gamma rays emitted from the radioisotopes 60Co and 137Cs, or high energy electrons and X-rays produced by machine sources. The use of ionising radiation to destroy harmful biological organisms in food is considered a safe, well proven process that has found many applications. Depending on the absorbed dose of radiation, various effects can be achieved resulting in reduced storage losses, extended shelf life and/or improved microbiological and parasitological safety of foods. The most common irradiated commercial products are spices and vegetable seasonings. Spice irradiation is increasingly recognised as a method that reduces post-harvest losses, ensures hygienic quality, and facilitates trade with food products. This article reviews recent activities concerning food irradiation, focusing on the irradiation of spices and dried vegetable seasonings from the food safety aspect

  6. The radiation protection environmental assesment for 60Co irradiation room

    International Nuclear Information System (INIS)

    Zheng Meiyang; Jin Guohua; Shen Genfang

    2010-01-01

    60 Co source is applied in the process such as sterilizing agricultural products in irradiation room of some Academy of Agricultural Sciences, which is very effective in agricultural applications. However, 60 Co is highly toxic, once the leak, the consequences would be disastrous. So it is necessary to summarize the radiation protection and safety evaluation of the irradiation room indoor and outdoor, to ensure the health and lives of the staff and the surrounding population. The radiation detectors monitor six points around the irradiation room. Results show that design of irradiation room of Academy of Agricultural Sciences are mostly safe and reliable, regardless of the source in working condition. And consequences also show 60 Co source in the normal operating will not put adverse effects on the surrounding environment. In addition, the outer radiation protective measures are also outlined, in view of 60 Co own identity. (authors)

  7. Sterilization plants equipped with the isotopic gamma radiation sources

    International Nuclear Information System (INIS)

    Mehta, K.; Chmielewski, A.G.

    2007-01-01

    Presentation describes different isotopic gamma radiation sources applicable for sterilization of food and medical materials. Certain gamma pallet irradiators, mini gamma irradiators and different scale gamma tote irradiators are presented. It is concluded, that about two hundreds plants with gamma radiation sources operates in different countries. However, industrially developed countries must construct much more plants than operates now

  8. Dyeing of γ-irradiated cotton with natural flavonoid dye extracted from irradiated onion shells (Allium cepa) powder

    Science.gov (United States)

    Rehman, Fazal-ur; Adeel, Shahid; Shahid, Muhammad; Bhatti, Ijaz Ahmad; Nasir, Faiza; Akhtar, Nasim; Ahmad, Zulfiqar

    2013-11-01

    Powder of Onion shells as a source of natural flavonoid dye (Quercetin) and cotton fabrics were exposed to absorbed doses of 2, 4, 6, 8 and 10 kGy using Cs-137 gamma irradiator. Irradiated and un-irradiated dye powder was used for extraction of quercetin as well as antibacterial, hemolytic and antioxidant activities were also determined to observe the effect of radiation. Furthermore, color strength and colourfastness of irradiated fabrics were improved by using pre and post-mordants such as alum and iron. It is found that 4 kGy is the optimal absorbed dose for extraction of natural quercetin extracted from onion shells while maximum color strength and acceptable fastness properties are obtained on dyeing of irradiated fabric at 60 °C keeping M:L of 1:30 using 10% alum as pre-mordant and 6% alum as post-mordant. Gamma irradiation has not only improved the color strength of the dye using irradiated cotton but also that of colourfastness properties.

  9. Interstitial irradiation for craniopharyngioma

    International Nuclear Information System (INIS)

    Barlas, O.; Bayindir, C.; Can, M.

    2000-01-01

    The results of interstitial irradiation treatment for craniopharyngioma in two patients with six year follow-ups are presented. Stereotactic interstitial irradiation with iodine-125 sources as sole therapy was employed in two adult patients who refused surgical resection. The diagnoses were confirmed by stereotactic biopsy. The first tumour which underwent interstitial irradiation was solid and 4 cm in diameter, and the second, 2.7 cm in diameter, had both cystic and solid components. The implanted iodine-125 seeds delivered 67 Gy and 60 Gy to tumour periphery at the rate of 12 and 14 cGy/h, respectively, were removed at the end of designated radiation periods. Tumour shrinkage and central hypo density, first observed 3 months after irradiation, continued until one tumour shrank to less than 1 cm at 12 months, and the other disappeared completely at 24 months. In both cases functional integrity was restored, and neither radiation induced toxicity nor recurrence has occurred six years after treatment. The results in these two cases suggest that solid craniopharyngiomas are sensitive to interstitial irradiation. (author)

  10. Research on food irradiation in Indonesia

    International Nuclear Information System (INIS)

    Hilmy, N.; Maha, M.; Chosdu, R.

    1986-01-01

    Studies on various aspects of food irradiation have been done in Indonesia since 1968, mainly at the Centre for the Application of Isotopes and Radiation, National Atomic Energy Agency of Indonesia. Three irradiation facilities available at the Centre are gamma cell-220, panoramic batch irradiator, and latex irradiator with the present source capacities of about 1.1, 40, and 163.8 kCi Co-60, respectively. In this paper, the present status of research and development on irradiation is presented, covering (1) spices and medicinal plants, (2) rice, wheat flour and coffee bean, (3) fish and fishery products, (4) animal feed, and (5) ongoing projects including fresh fruits, cacao beans, and cashew nut. The Sub-Committee for the Control of Irradiation of Food and Medical Products, set up in August 1984, has prepared the draft of recommendations regarding the regulation for application of food irradiation in Indonedia and the draft of Regulation for the Control of and Trade in Irradiated Food and Traditional Drug to be issued by the government. (Namekawa, K.)

  11. Safety protection and technical improvement of 60Co irradiation facilities

    International Nuclear Information System (INIS)

    Zhou Yongxing; Liang Cannan

    1993-01-01

    To ensure personal safety, some improvements has been made in the design of 60 Co irradiation compartment. The shielding door was interlocked while the 60 Co source to be lifted to the irradiation position or lowered to the shielded position. A universal change-over switch was used to cut the power supply when the source moved beyond the limits. Both γ-ray alarm and a closed-TV system were adopted. The electromagnetic attraction method was employed to shift the 60 Co source from the Pb container to the source pipe

  12. Alternative irradiation system for efficiency manganese bath determination

    Energy Technology Data Exchange (ETDEWEB)

    Passos Leite, Sandro, E-mail: sandro@ird.gov.b [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Wagner Pereira, Walsan, E-mail: walsan@ird.gov.b [Instituto de Radioprotecao e Dosimetria LNMRI/IRD/CNEN, Av. Salvador Allende, s/no, Recreio dos Bandeirantes, CEP: 22780-160, Rio de Janeiro (Brazil); Xavier da Silva, Ademir, E-mail: ademir@con.ufrj.b [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Simoes da Fonseca, Evaldo, E-mail: evaldo@ird.gov.b [Instituto de Radioprotecao e Dosimetria LNMRI/IRD/CNEN, Av. Salvador Allende, s/no, Recreio dos Bandeirantes, CEP: 22780-160, Rio de Janeiro (Brazil); Souza Patrao, Karla Cristina de, E-mail: karla@ird.gov.b [Instituto de Radioprotecao e Dosimetria LNMRI/IRD/CNEN, Av. Salvador Allende, s/no, Recreio dos Bandeirantes, CEP: 22780-160, Rio de Janeiro (Brazil)

    2010-12-15

    An alternative irradiation system, which works with a radionuclide neutron source and manganese sulphate solution volume have been proposed for efficiency determination of a Manganese Bath System (MBS). This irradiation system was designed by simulation with MCNP5 code, considering a californium neutron source in several manganese sulphate volumes and different neutron reflectors. Although its solution specific activity are less than those in nuclear reactors, the simulation results have showed that the irradiation system proposed takes a manganese neutron capture increase up to 200 times when it compared to manganese neutron capture from a MBS whose diameter is about 100 cm. That becomes possible to use those samples for some of the absolute specific activity measuring methods.

  13. Nutritional aspects of irradiated mangoes

    International Nuclear Information System (INIS)

    Singh, H.

    1990-06-01

    Mangoes, like most other fruits, constitute a small but very important part of human diet in tropical countries. Their carbohydrate content is a source of energy; however, their main importance is as a rich source of vitamins, particularly vitamins A and C. Increasing the shelf life of mangoes is desirable, since on ripening they become highly perishable and have a very short shelf life. Low-dose irradiation is considered to be a good method for extending their shelf life. This literature review examines the effect of radiation processing on the nutrients in mangoes. In general, irradiation has little effect on the main nutrients, vitamin C, carotenoids and carbohydrates. There is a significant loss of vitamin C only in a few varieties of mangoes, while in the others the vitamin C level is unaffected. The extension of shelf life also depends on the storage conditions, particularly temperature. While low-temperature storage followed by ripening at room temperature leads to high vitamin C levels, it reduces the carotenoid levels in some varieties. Thus, the storage and the ripening temperatures should be optimized for each variety to obtain the maximum benefit of irradiation. Long-term, multi-generation rat feeding studies to assess the wholesomeness of irradiated mangoes have shown no adverse effects

  14. Development of food irradiation technology and consumer attitude toward irradiated food in Korea

    International Nuclear Information System (INIS)

    Kwon, Joong-Ho; Byun, Myung-Woo; Cho, Han-Ok

    1992-01-01

    In Korea, the well-integrated research of biological effects of radiation has been launched from the late 1960s. As research activities, the following food items have been dealt with: sprouting foods, fruits, mushrooms, grains, spices or mixed condiments, fish or fishery products, meat or meat products, and fermented foods. The usage of gamma radiation from 60 Co source is now authorized for food irradiation of the following items: potato, onion, garlic, chestnut, mushroom, dried mushroom, dried spices (including red pepper, garlic, black pepper, onion, ginger, and green onion), dried meat, powdered fish and shellfish, soybean paste powder, hot pepper paste powder, soybean sauce powder, and starch. Since the authorization of food irradiation in 1985, consumers' acceptance has been considered the most important. The survey evaluating the basic perception and attitule toward food irradiation revealed the following results. Consumers' awareness of food irradiation was 82%, with significantly higher in radiation workers than the general public (p<0.0001). Seventy-five percent distinguished the contaminated food by radionuclides from irradiated food. In purchasing irradiated foods, 50.9% required more information. The contribution of irradiated foods to wholesomeness was suspicious in 51%, acceptable in 33%, and uncertain in 16%. If information about the benefits of irradiation is provided to consumers, positive response was increased to 60%. The most critical impediment in the commercial application of food irradiation was found to have resulted from the general consumers' slow acceptance; however, consumers' attitude to irradiated food became positive if they understood the safety and advantages of this technology. The most important task is to overcome consumers' psychological resistance and transporting matters of the products to be irradiated. (N.K.)

  15. Allograft tolerance in pigs after fractionated lymphoid irradiation. I. Skin grafts after partial lateral irradiation and bone marrow cell grafting

    International Nuclear Information System (INIS)

    Vaiman, M.; Daburon, F.; Remy, J.; Villiers, P.A.; de Riberolles, C.; Lecompte, Y.; Mahouy, G.; Fradelizi, D.

    1981-01-01

    Experiments with pigs have been performed to establish bone marrow chimerism and skin graft tolerance between SLA genotyped animals. Recipients were conditioned by means of fractionated partial irradiation from lateral cobalt sources (partial lateral irradiation (PLI)). The head, neck, and lungs were protected with lead, the rest of the body being irradiated including the thymus, the majority of lymphoid organs with spleen, and most of the bone marrow sites

  16. Response of pig skin to single doses of irradiation from strontium-90 sources of differing surface area

    Energy Technology Data Exchange (ETDEWEB)

    Hopewell, J.W.; Hamlet, R.; Peel, D. (Churchill Hospital, Oxford (UK). Research Inst.)

    1985-08-01

    In the present investigations the effects of irradiation of pig skin with 22.5 and 40 mm diameter /sup 90/Sr plaques are compared. In addition to comparing peak epithelial reactions, comparisons were also made as to the healing times for comparable peak skin reactions for each field size. The ED/sub 50/ values (dose to produce moist desquamation in 50% of the skin fields) 26.5 +- 1.5 Gy for the 22.5 diameter field was not significantly different from that obtained for the larger 40 mm diameter source (ED/sub 50/ 29.0 +- 1.5 Gy).

  17. Intracavity irradiation with deferred radioactive load technique, remote control high activity sources

    Energy Technology Data Exchange (ETDEWEB)

    Badell, M.; Lejarcegui, J.A.; Guix, B.; Rubio, A.; Pons, F.; Farrus, B.

    1988-01-01

    From December 1981 to September 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavity irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%), moderate in 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1,055 to 7,320 cGy. Maximum total rectal dose administration greater than 4,000 cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant prognostic factors (p < 0.001) of severe rectal complications.

  18. Intracavitary irradiation with deferred radioactive load Technique, remote control high activity sources

    International Nuclear Information System (INIS)

    Badell, M.; Lejarceguir, J.A.; Guix, B.; Rubio, A.; Pons, A.; Farrus, B.

    1988-01-01

    From december 1981 to septembre 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavitary irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%). moderate in 15 (10%) and severe in 15 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1.055 to 7.320 cGy. Maximum total rectal dose administration greater than 4, cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant prognostic factors (p0.001) of severe rectal complications. (Author)

  19. Projection of needs for gamma radiation sources and other radioisotopes and assessment of alternatives for providing radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Ross, W.A.; Jensen, G.A.; Clark, L.L.; Eakin, D.E.; Jarrett, J.H.; Katayama, Y.B.; McKee, R.W.; Morgan, L.G.; Nealey, S.M.; Platt, A.M.; Tingey, G.L.

    1989-06-01

    Pacific Northwest Laboratory reviewed the projected uses and demands for a variety of nuclear byproducts. Because the major large-scale near-term demand is for gamma irradiation sources, this report concentrates on the needs for gamma sources and evaluates the options for providing the needed material. Projections of possible growth in the irradiation treatment industry indicate that there will be a need for 180 to 320 MCi of /sup 60/Co (including /sup 137/Cs equivalent) in service in the year 2000. The largest current and projected use of gamma irradiation is for the sterilization of medical devices and disposable medical supplies. Currently, 40% of US disposable medical products are treated by irradiation, and within 10 years it is expected that 90% will be treated in this manner. Irradiation treatment of food for destruction of pathogens or parasites, disinfestation, or extension of allowable storage periods is estimated to require an active inventory of 75 MCi of /sup 60/Co-equivalent gamma source in about a decade. 90 refs., 7 figs., 25 tabs.

  20. Projection of needs for gamma radiation sources and other radioisotopes and assessment of alternatives for providing radiation sources

    International Nuclear Information System (INIS)

    Ross, W.A.; Jensen, G.A.; Clark, L.L.

    1989-06-01

    Pacific Northwest Laboratory reviewed the projected uses and demands for a variety of nuclear byproducts. Because the major large-scale near-term demand is for gamma irradiation sources, this report concentrates on the needs for gamma sources and evaluates the options for providing the needed material. Projections of possible growth in the irradiation treatment industry indicate that there will be a need for 180 to 320 MCi of 60 Co (including 137 Cs equivalent) in service in the year 2000. The largest current and projected use of gamma irradiation is for the sterilization of medical devices and disposable medical supplies. Currently, 40% of US disposable medical products are treated by irradiation, and within 10 years it is expected that 90% will be treated in this manner. Irradiation treatment of food for destruction of pathogens or parasites, disinfestation, or extension of allowable storage periods is estimated to require an active inventory of 75 MCi of 60 Co-equivalent gamma source in about a decade. 90 refs., 7 figs., 25 tabs

  1. Development of X-ray photoelectron microscope with a compact X-ray source generated by line-focused laser irradiation

    International Nuclear Information System (INIS)

    Yamaguchi, N.; Takahashi, Z.; Nishimura, Y.; Watanabe, K.; Okamoto, Y.; Sakata, A.; Azuma, H.; Hara, T.

    2005-01-01

    A laboratory-sized X-ray photoelectron microscope was constructed using a compact X-ray source produced by line-focused laser irradiation. The system is a scanning type photoelectron microscope where X-ray beam is micro-focused via Schwarzschild optics. A compact laser-plasma X-ray source has been developed with a YAG laser, a line-focus lens assembly, an Al tape-target driver and a debris prevention system. The 13.1 nm X-ray was delivered along line plasma whose length was 0.6 or 11 mm with higher intensity than that from a point-focused source. The Schwarzschild optics having the designed demagnification of 224, which was coated with Mo/Si multilayers for 13.1 nm X-ray, was set on the beamline 1 m distant from the source. The electron energy analyser was a spherical capacitor analyser with the photoelectron image detection system that was suited for detection of vast photoelectrons excited by an X-ray pulse of ns-order duration. The spatial resolution less than 5 μm has been confirmed from the variation of As 3d electron intensity along the position of the GaAs sample coated with a photo-resist test pattern

  2. A summary of recent developments in the sludge irradiation program at Sandia laboratories

    International Nuclear Information System (INIS)

    Morris, M.E.; Sivinski, J.S.; Brandon, J.R.; Neuhauser, K.S.; Ward, R.L.

    1978-01-01

    Sandia Laboratories has shifted the emphasis of its Sewage Sludge Irradiation Program toward treating dried sewage sludges rather than liquid sludges for the following reasons: (1) cities' interests in composting sewage sludge before final disposal; (2) need for disinfection of the product before sale to the public; and (3) low cost of disinfection by radiation processing. As a result of this shift, the Sandia Irradiator for Dried Sewage Solids (SIDSS), was designed and is near completion. The irradiator will treat up to 8 tons/day of solids with a 1 megarad absorbed dose. A bucket conveyor will transport the sewage sludge past a 1 megacurie cesium-137 γ-ray source. If a lower dose than 1 megarad is acceptable for disinfection, the daily throughput of the irradiator will be correspondingly increased. The irradiator is designed so that the cesium-137 γ-ray sources used to charge the facility can be manipulated underwater. After source unloading is complete, the water will be drained and the irradiator will be operated dry. Either bagged or bulk solids can be irradiated with the system. (Auth.)

  3. Pallet irradiators for food processing

    International Nuclear Information System (INIS)

    McKinnon, R.G.; Chu, R.D.H.

    1985-01-01

    This paper looks at the various design concepts for the irradiation processing of food products, with particular emphasis on handling the products on pallets. Pallets appear to offer the most attractive method for handling foods from many considerations. Products are transported on pallets. Warehouse space is commonly designed for pallet storage and, if products are already palletized before and after irradiation, then labour could be saved by irradiating on pallets. This is also an advantage for equipment operation since a larger carrier volume means lower operation speeds. Different pallet irradiator design concepts are examined and their suitability for several applications are discussed. For example, low product holdup for fast turn around will be a consideration for those operating an irradiation 'service' business; others may require a very large source where efficiency is the primary requirement and this will not be consistent with low holdup. The radiation performance characteristics and processing costs of these machines are discussed. (author)

  4. Irradiation and electrostatic separator

    International Nuclear Information System (INIS)

    Schultz, M.A.

    1976-01-01

    An apparatus for collecting pollutants in which a passageway is formed to define a path for industrial gases passing therethrough is described. A plurality of isotope sources extend along at least a portion of the path followed by the industrial gases to provide a continuing irradiation zone for pollutants in the gases. Collecting electrode plates are associated with such an irradiation zone to efficiently collect particulates as a result of an electrostatic field established between such plates, particularly very small particulates. The series of isotope sources are extended for a length sufficient to attain material improvement in the efficiency of collecting the pollutants. Such an effective length is established along a substantially unidirectional path of the gases, or preferably a reversing path in a folded conduit assembly to attain further efficiency by allowing more compact apparatus structures

  5. Numerical analysis of hydrogen production via methane steam reforming in porous media solar thermochemical reactor using concentrated solar irradiation as heat source

    International Nuclear Information System (INIS)

    Wang, Fuqiang; Tan, Jianyu; Shuai, Yong; Gong, Liang; Tan, Heping

    2014-01-01

    Highlights: • H 2 production by hybrid solar energy and methane steam reforming is analyzed. • MCRT and FVM coupling method is used for chemical reaction in solar porous reactor. • LTNE model is used to study the solid phase and fluid phase thermal performance. • Modified P1 approximation programmed by UDFs is used for irradiative heat transfer. - Abstract: The calorific value of syngas can be greatly upgraded during the methane steam reforming process by using concentrated solar energy as heat source. In this study, the Monte Carlo Ray Tracing (MCRT) and Finite Volume Method (FVM) coupling method is developed to investigate the hydrogen production performance via methane steam reforming in porous media solar thermochemical reactor which includes the mass, momentum, energy and irradiative transfer equations as well as chemical reaction kinetics. The local thermal non-equilibrium (LTNE) model is used to provide more temperature information. The modified P1 approximation is adopted for solving the irradiative heat transfer equation. The MCRT method is used to calculate the sunlight concentration and transmission problems. The fluid phase energy equation and transport equations are solved by Fluent software. The solid phase energy equation, irradiative transfer equation and chemical reaction kinetics are programmed by user defined functions (UDFs). The numerical results indicate that concentrated solar irradiation on the fluid entrance surface of solar chemical reactor is highly uneven, and temperature distribution has significant influence on hydrogen production

  6. Food preservation by irradiation

    International Nuclear Information System (INIS)

    Oztasiran, I.

    1984-01-01

    Irradiation is a physical process for treating food and as such it is comparable to other processing techniques such as heating or freezing foods for preservation. The energy level used in food irradiation is always below that producing radioactivity in the treated food, hence this aspect can be totally excluded in wholesomeness evaluations. Water is readily ionized and may be the primary source of ionization in foods with secondary effects on other molecules, possibly more a result of water ionization than of direct hits. In the presence of oxygen, highly reactive compounds may be produced, such as H, H 3 0+ and H 2 O 2 . Radiation at the energy flux levels used for food (<2 MeV) does not induce radioactivity. Food irradiation applications are already technically and economically feasible and that food so treated is suitable for consumption. Food irradiation techniques can play an important role for an improved preservation, storage and distribution of food products. (author)

  7. Effect of interaction between irradiation-induced defects and intrinsic defects in the pinning improvement of neutron irradiated YBaCuO sample

    International Nuclear Information System (INIS)

    Topal, Ugur; Sozeri, Huseyin; Yavuz, Hasbi

    2004-01-01

    Interaction between the intrinsic (native) defects and the irradiation-induced defects created by neutron irradiation was examined for the YBCO sample. For this purpose, non-superconducting Y-211 phase was included to the Y-123 samples at different contents as a source of large pinning center. The critical current density enhancement with the irradiation for these samples were analysed and then the role of defects on pinning improvement was discussed

  8. Effect of interaction between irradiation-induced defects and intrinsic defects in the pinning improvement of neutron irradiated YBaCuO sample

    Energy Technology Data Exchange (ETDEWEB)

    Topal, Ugur; Sozeri, Huseyin; Yavuz, Hasbi

    2004-08-01

    Interaction between the intrinsic (native) defects and the irradiation-induced defects created by neutron irradiation was examined for the YBCO sample. For this purpose, non-superconducting Y-211 phase was included to the Y-123 samples at different contents as a source of large pinning center. The critical current density enhancement with the irradiation for these samples were analysed and then the role of defects on pinning improvement was discussed.

  9. Development of an apparatus for measuring the thermal conductivity of irradiated or non-irradiated graphite

    International Nuclear Information System (INIS)

    Bocquet, M.; Micaud, G.

    1962-01-01

    An apparatus was developed for measuring the thermal conductivity coefficient K of irradiated or non-irradiated graphite. The measurement of K at around room temperature with an accuracy of about 6% is possible. The study specimen is placed in a vacuum between a hot and a cold source which create a temperature gradient ΔΘ/ Δx in the steady state. The amount of heat transferred, Q, is deduced from the electrical power dissipated at the hot source, after allowing for heat losses. The thermal conductivity coefficient is defined as: K = Q/S. Δx/ΔΘ, S being the cross section of the sample. Systematic studies have made it possible to determine the mean values of the thermal conductivity. (authors) [fr

  10. Development of an irradiation system for a small size continuous run multipurpose gamma irradiator; Desenvolvimento do sistema de irradiacao em um irradiador multiproposito de cobalto-60 tipo compacto

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, Wilson Aparecido Parejo

    2005-07-01

    The Radiation Technology Center from Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Brazil, developed with a revolutionary design and national technology, a small size continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotate door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m{sup 2} of floor area, the irradiator design is product overlap sources and the maximum capacity of cobalt-60 wet sources is 37 P Bq (1 MCi). The performed quantification program of this multipurpose irradiator was based on AAMI/ISO 11137 standard, which recommends the inclusion of the following elements: installation and process quantification. The initial load of the multipurpose irradiator was 3.4 P Bq (92.1 k Ci) with 13 cobalt-60 sources model C-188, supplied by MDS Nordion Ion Technologies - Canada. For irradiator dose optimization, the source distribution was done using the software Cadgamma developed by IPEN-CNEN/SP. The poly-methylmethacrylate (PMMA) dosimeters system, certified by the International Dose Assurance Service (IDAS) of the International Atomic Energy Agency (IAEA) was used for irradiator dose mapping. The economic analysis, performance concerning to dose uniformity and cobalt-60 utilization efficiency were calculated and compared with other commercial

  11. Detection of garlic gamma-irradiated by assay comet

    International Nuclear Information System (INIS)

    Moreno Alvarez, Damaris L.; Miranda, Enrique F. Prieto; Carro, Sandra; Iglesias Enrique, Isora; Matos, Wilberto

    2009-01-01

    The garlic samples were irradiated in a facility with 60 Co sources, at absorbed dose values of 0-0,15 kGy. The detection method utilized for the identification of the irradiated garlic was biological comet assay. The samples were classified post-irradiation several times. The irradiated samples showed high strand breaks of DNA exhibiting comets of several forms, while the not irradiated and lower dose samples showed a behavior like round shape and light comets. Significant differences were found for higher absorbed dose values at 0.06 kGy, this absorbed dose value is corresponding with the applied dose value at this food in order to avoid the germination. (author)

  12. Measurement of the thermal neutron self shielding coefficient in the Syrian miniature neutron source reactor inner irradiation site using the dy soils

    International Nuclear Information System (INIS)

    Khattab, K.; Khamis, I.

    2007-01-01

    Measurement of the thermal self shielding coefficient ( Gth ) in the Syrian Miniature Neutron Source Reactor (MNSR) inner irradiation site using Dy foils is presented in this paper. The thermal self shielding coefficient is measured as a function of the foil thickness or numbers. The mathematical equation which calculates the average relative radioactivity (Bq/g) versus the foil number is found as well.

  13. Twenty two cases of skin cancer following irradiation

    International Nuclear Information System (INIS)

    Ishihara, Kazuyuki; Hayasaka, Ken-ichi

    1978-01-01

    21 cases of spinocellular carcinoma (2 cases of them complicated basal-cell carcinoma) and a case of fibrosarcoma following irradiation were observed. The source which poses some problems in soft x-ray used for the treatment. Soft x-ray is used for the treatment of eczema, progressive keratodermia palmaris et plantaris, pustulosis palmaris et plantaris, trichophytia, hemangioma etc.. However, details of the irradiation are unknown in many of the cases. Carcinogenesis was noted 10 years at least-36 years at most after the irradiation. In 7 cases of 12 which received soft x-ray irradiation (including superficial therapy), multiple or double cancer was observed. In many of the cases, irradiation is repeated at low voltage, and radiation keratosis preceded cancerization. As the therapy of this type of keratosis, wide excision and skin grafting are generally recommended. The prognoses of the cases which received this therapy seem to be favorable. There were 6 cases of death out of 22 cases. The mortality (23.8%) is not high except for that of fibrosarcoma. Utilization of radiotherapy for skin diseases in future will be judged after a long-period followup. However, repeated irradiation for a long period, even if the source is extra-soft or limiting ray, should be avoided. (Ueda, J.)

  14. Radiation Safety of Gamma, Electron and X Ray Irradiation Facilities. Specific Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2015-01-01

    The objective of this Safety Guide is to provide recommendations on how to meet the requirements of the BSS with regard to irradiation facilities. This Safety Guide provides specific, practical recommendations on the safe design and operation of gamma, electron and X ray irradiators for use by operating organizations and the designers of these facilities, and by regulatory bodies. SCOPE. The facilities considered in this publication include five types of irradiator, whether operated on a commercial basis or for research and development purposes. This publication is concerned with radiation safety issues and not with the uses of irradiators, nor does it cover the irradiation of product or its quality management. The five types of irradiator are: - Panoramic dry source storage irradiators; - Underwater irradiators, in which both the source and the product being irradiated are under water; - Panoramic wet source storage irradiators; - Electron beam irradiation facilities, in which irradiation is performed in an area that is potentially accessible to personnel, but that is kept inaccessible during the irradiation process; - X ray irradiation facilities, in which irradiation is performed in an area that is potentially accessible to personnel, but that is kept inaccessible during the irradiation process. Consideration of non-radiation-related risks and of the benefits resulting from the operation of irradiators is outside the scope of this Safety Guide. The practices of radiotherapy and radiography are also outside the scope of this Safety Guide. Category I gamma irradiators (i.e. 'self-shielded' irradiators) are outside the scope of this Safety Guide

  15. Influence of different irradiation facilities on the response of radioprotection devices

    International Nuclear Information System (INIS)

    Heeren de Oliveira, A.

    1984-05-01

    An EIC 1 extrapolation chamber, flushed with a methan based tissue equivalent gas is presented. This measuring device serves as a reference instrument to calibrate in tissue absorbed dose beta beams from different irradiation facilities; point radioactive sources, sources used with beam flattening filters, large area sources simulated by moving a point source. The source to detector distance has to be greater than 3 cm, requiring a transfer dosemeter for smaller distances. Influence of these different irradiation geometries has been studied on several radioprotection instruments (babyline, individual dosemeter, ionisation chamber), using three radionucleides: 147 Pm, 204 Tl, 90 Sr + 90 Y [fr

  16. Operating experience with gamma ray irradiators

    International Nuclear Information System (INIS)

    Fraser, F.M.; Ouwerkerk, T.

    1980-01-01

    The experience of Atomic Energy of Canada, Limited (AECL) with radioisotopes dates back to the mid-1940s when radium was marketed for medical purposes. Cobalt-60 came on the scene in 1949 and within a few years a thriving business in cancer teletherapy machines and research irradiators was developed. AECL's first full-scale cobalt-60 gamma ray sterilizer for medical products was installed in 1964. AECL now has over 50 plants and 30 million curies in service around the world. Sixteen years of design experience in cobalt-60 sources, radiation shielding, safety interlock systems, and source pass mechanisms have made gamma irradiators safe, reliable, and easy to operate. This proven technology is being applied in promising new fields such as sludge treatment and food preservation. Cesium-137 is expected to be extensively utilized as the gamma radiation source for these applications

  17. Microbial determination of Cumin by gamma irradiation

    International Nuclear Information System (INIS)

    Motamedi, F.; Abhari, M.; Fathollahi, H.; Arbabi, K.

    2002-01-01

    Cumin is one of the valuable export items of Iran, and like most of the agricultural products it is contaminated by microorganisms. Due to importance of this product, the gamma irradiation method, which has applications in microbial decontamination, has been used for the improving its quality and increasing the shelf life-time. For this purpose pak ages of 10 gr of cumin were irradiated by 2,4,6 and 8 KGy from 60 Co source. With each dose, four samples were irradiated and results were compared with controlled not irradiated samples. According to the standard limitation of bacteria and molds the total optimum doses are 7.5 and 5 KGy respectively

  18. 10 CFR 36.31 - Control of source movement.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Control of source movement. 36.31 Section 36.31 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Design and Performance Requirements for Irradiators § 36.31 Control of source movement. (a) The mechanism that moves the...

  19. Effect of irradiation on foodstuffs Pt. 4

    International Nuclear Information System (INIS)

    Kluender, U.; Boegl, W.

    1980-01-01

    In the present study of the relevant literature the results of irradiation experiments with 32 foodstuffs have been compiled and discussed. This study is intented to give a survey on chemical changes in irradiated food, and neither microbiological nor toxicological and physiological aspects were taken into account. The results published by the authors of the original papers have been compiled in form of a dictionary which contains all important data such as radiation source, irradiation conditions, treatment and characteristics of the sample, investigation methods, results of the chemical and organoleptical changes etc. In addition, the effects of irradiation both on individual food substances and individual groups of foodstuffs have been summarized. Furthermore, the effects of irradiation on sensory characteristics and the atmospheric influence during irradiation are given seperately. The last chapter contains a comparison between the chemical changes of food due to irradiation treatment and those caused by conventional methods. The final discussion of the results will be published seperately. (orig./MG) [de

  20. Sensorial evaluation of irradiated mangoes

    International Nuclear Information System (INIS)

    Broisler, Paula Olhe; Cruz, Juliana Nunes da; Sabato, Susy Frey

    2007-01-01

    Mango (Mangifera indica L.) is a tropical fruit of great economical relevance in the world, mainly for tropical countries like Brazil. It consists in the second tropical fruit more important grown in the world. On the other hand it is a very perishable fruit and its delivery to distant points is restricted due to short shelf life at environmental temperature. Food irradiation process is applied to fruits for their preservation, once it promotes disinfestation and even maturation retard, among other mechanisms. The Brazilian legislation permits the food irradiation and does not restrict the doses to be delivered. In order to verify eventual changes, sensorial evaluation is very important to study how irradiation affects the quality of the fruit and its acceptability. Mangoes were irradiated in a Cobalto-60 source, from the Radiation Technology Center, CTR, of IPEN/CNEN-SP at doses 0,5 kGy e 0,75 kGy. The sensorial evaluation was measured through Acceptance Test where irradiated samples were offered together with control sample to the tasters who answered their perception through hedonic scale. The parameters Color, Odor, Flavor and Texture were analyzed. Statistical analysis showed that only Odor parameter was different from control (sample irradiated at 0.5 kGy). Few tasters indicated that irradiated mangoes had fewer odors in relation to non-irradiated samples. (author)

  1. Sensorial evaluation of irradiated mangoes

    Energy Technology Data Exchange (ETDEWEB)

    Broisler, Paula Olhe; Cruz, Juliana Nunes da; Sabato, Susy Frey [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: paulabroisler@hotmail.com; juliananc@ig.com.br; sfsabato@ipen.br

    2007-07-01

    Mango (Mangifera indica L.) is a tropical fruit of great economical relevance in the world, mainly for tropical countries like Brazil. It consists in the second tropical fruit more important grown in the world. On the other hand it is a very perishable fruit and its delivery to distant points is restricted due to short shelf life at environmental temperature. Food irradiation process is applied to fruits for their preservation, once it promotes disinfestation and even maturation retard, among other mechanisms. The Brazilian legislation permits the food irradiation and does not restrict the doses to be delivered. In order to verify eventual changes, sensorial evaluation is very important to study how irradiation affects the quality of the fruit and its acceptability. Mangoes were irradiated in a Cobalto-60 source, from the Radiation Technology Center, CTR, of IPEN/CNEN-SP at doses 0,5 kGy e 0,75 kGy. The sensorial evaluation was measured through Acceptance Test where irradiated samples were offered together with control sample to the tasters who answered their perception through hedonic scale. The parameters Color, Odor, Flavor and Texture were analyzed. Statistical analysis showed that only Odor parameter was different from control (sample irradiated at 0.5 kGy). Few tasters indicated that irradiated mangoes had fewer odors in relation to non-irradiated samples. (author)

  2. Irradiation of a barrier film: analysis of some mass transfer aspects

    International Nuclear Information System (INIS)

    Deschenes, L.; Arbour, A.; Brunet, F.; Court, M.A.; Doyon, G.J.; Fortin, J.; Rodrigue, N.

    1995-01-01

    Irradiation of a Nylon/PVDC/EVA barrier film caused changes in mass transfers of the packaging material. Sensory evaluation of irradiated water indicated development of off-odours and taints, even at 1 kGy. This behaviour differed with the irradiation source (gamma or beta). Aldehydes and polymer hydrocarbons were involved in the development of irradiation tainting from packaging film. (Author)

  3. Clarification of leachate from reclaimed ground by electron beam irradiation

    International Nuclear Information System (INIS)

    Yamazaki, Masao; Sawai, Teruko; Shimokawa, Toshinari; Sawai, Takeshi

    1985-01-01

    To decompose organic matters such as humic acid and fulvous acid in the leachate from reclaimed ground, an electron beam irradiation technique was examined because of availability of higher dose rate than a 60 Co γ-ray source. This paper describes results of the above-mentioned preliminary examination. Test water was collected from No.15 dumping site at the Tokyo Bay. Irradiation sample was prepared by filtration with a filter and decarbonation with sulfuric acid. Fulvous acid solution by eliminating humic acid was also served for the examination. Electron beam irradiation of the sample solution was made with a Van de Graaf accelerator by 1.5 MeV, 140 Gy/sec of irradiation condition and with a dynamitron by 2.0 MeV, 25 kGy/pass of the condition. It was clarified that oxygen bubbling velocity during the irradiation did not affect much for the decrease rate of total organic matters (TOC) within 0.5 to 3.0 1/min of an experimental condition. As for radiation doses and TOC decrease, TOC was decreased much for lower dose rate irradiation (Van de Graaf accelerator), lower initial TOC concentration, or addition of hydrogen peroxide. For the combined treatment of radiation and flocculation to aim at irradiation dose decrease, fulvous acid solution was served for the test. Lower dose irradiation with a 60 Co source showed better TOC elimination and it was concluded that combination with flocculation was effective for the dose reduction. It was also found experimentally that TOC decrease behavior by the both radiation source was different due to temperature effect and further study should be made for the development of the practical electron beam irradiation technique. (Takagi, S.)

  4. Radiation safety of gamma and electron irradiation facilities

    International Nuclear Information System (INIS)

    1992-01-01

    There are currently some 160 gamma irradiation facilities and over 600 electron beam facilities in operation throughout virtually all Member States of the IAEA. The most widespread uses of these facilities are for the sterilization of medical and pharmaceutical products, the preservation of foodstuffs, polymer synthesis and modification, and the eradication of insect infestation. The safety record of this industry has been very good. Nevertheless, there is a potential for accidents with serious consequences. Gamma and electron beam facilities produce very high dose rates during irradiation, so that a person accidentally present in the irradiation chamber can receive a lethal dose within minutes or seconds. Precautions against uncontrolled entry must therefore be taken. Furthermore, gamma irradiation facilities contain large amounts of radioactivity and if the mechanism for retracting the source is damaged, the source may remain exposed, inhibiting direct access to carry out remedial work. Contamination can result from corroded or damaged sources, and decontamination can be very expensive. These aspects clearly indicate the need to achieve a high degree of safety and reliability in the facilities. This can be accomplished by effective quality control together with careful design, manufacture, installation, operation and decommissioning. The guidance in this Safety Series publication is intended for competent authorities responsible for regulating the use of radiation sources as well as the manufacturers, suppliers, installers and users of gamma and electron beam facilities. 20 refs, 6 figs

  5. Shihoro irradiation plant for potato

    International Nuclear Information System (INIS)

    Kameyama, Kenji

    1985-01-01

    There have been rapid moves toward the commercialization of food irradiation around the world since November, 1980, when a joint FAO/IAEA/WHO expert committee made a recommendation on the wholesomeness of irradiated foods. The bold US move toward the commercialization has had a great impact. Ahead of these move around the world, Japan built a commercial irradiation plant in 1974, which has been operated for inhibiting the sprouting of potatoes. This plant was built in Shihoro, Hokkaido, and two thirds of the 400 million yen construction cost was provided by the Government and Hokkaido authorities for five agricultural cooperative associations of four local townships. Since then, the plant has been under the joint management of these cooperatives. The aim and circumstance of the plant construction are described. The mechanism of the plant with conveyors, a turntable and a Co-60 source of 300,000 Ci is shown. The plant processes 15 tons of potatoes per hour with the dose from 60 to 150 Gy. Potato bruise and irradiation effect, irradiation time and effect, and post-irradiation storage temperature and potato quality are reported. (Kako, I.)

  6. Ionizing radiation source detection by personal TLD

    International Nuclear Information System (INIS)

    Marinkovic, O.; Mirkov, Z.

    2002-01-01

    The Laboratory for personal dosimetry has about 3000 workers under control. The most of them work in medicine. Some institutions, as big health centers, have different ionizing radiation sources. It is usefull to analyze what has been the source of irradiation, special when appears a dosimeter with high dose. Personal dosimetry equipment is Harshaw TLD Reader Model 6600 and dosimeters consist of two chips LiF TLD-100 assembled in bar-coded cards which are wearing in holders with one tissue-equivalent filter (to determine H(10)) and skin-equivalent the other (to determine H(0.07)). The calibration dosimeters have been irradiated in holders by different sources: x-ray (for 80keV and 100keV), 6 0C o, 9 0S r (for different distances from beta source) and foton beem (at radiotherapy accelerator by 6MeV, 10MeV and 18MeV). The dose ratio for two LiF cristals was calculated and represented with graphs. So, it is possible to calculate the ratio H(10)/H(0.07) for a personal TLD and analyze what has been the source of irradiation. Also, there is the calibration for determination the time of irradiation, according to glow curve deconvolution

  7. A Practical Irradiance Model for Bifacial PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill; MacAlpine, Sara; Deline, Chris; Asgharzadeh, Amir; Toor, Fatima; Riley, Daniel; Stein, Joshua; Hansen, Clifford

    2017-06-21

    A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-of-incidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using ray tracing software.

  8. Simulation of gamma-ray irradiation of lettuce leaves in a 137Cs irradiator using MCNP

    International Nuclear Information System (INIS)

    Kim, Jongsoon; Moreira, Rosana G.; Braby, Leslie A.

    2010-01-01

    Ionizing radiation effectively reduces the number of common microbial pathogens in fresh produce. However, the efficacy of the process for pathogens internalized into produce tissue is unknown. The objective of this study was to understand gamma irradiation of lettuce leaf structure exposed in a 137 Cs irradiator using MCNP. The simulated 137 Cs irradiator is a self-shielded device, and its geometry and sources are described in the MCNP input file. When the irradiation chamber is filled with water, lower doses are found at the center of the irradiation volume and the dose uniformity ratio (maximum dose/minimum dose) is 1.76. For randomly oriented rectangular lettuce leaf segments in the irradiation chamber, the dose uniformity ratio is 1.25. It shows that dose uniformity in the Cs irradiator is strongly dependent of the density of the sample. To understand dose distribution inside the leaf, we divided a lettuce leaf into a low density (flat) region (0.72 g/cm 3 ) and high density (rib) region (0.86 g/cm 3 ). Calculated doses to the rib are 61% higher than doses to the flat region of the leaf. This indicates that internalized microorganisms can be inactivated more easily than organisms on the surface. This study shows that irradiation can effectively reduce viable microorganism internalized in lettuce. (author)

  9. The response of pig skin to single doses of irradiation from strontium-90 sources of differing surface area

    International Nuclear Information System (INIS)

    Hopewell, J.W.; Hamlet, R.; Peel, D.

    1985-01-01

    In the present investigations the effects of irradiation of pig skin with 22.5 and 40 mm diameter 90 Sr plaques are compared. In addition to comparing peak epithelial reactions, comparisons were also made as to the healing times for comparable peak skin reactions for each field size. The ED 50 values (dose to produce moist desquamation in 50% of the skin fields) 26.5+-1.5 Gy for the 22.5 diameter field was not significantly different from that obtained for the larger 40 mm diameter source (ED 50 29.0+-1.5 Gy). (U.K.)

  10. LED-based UV source for monitoring spectroradiometer properties

    Science.gov (United States)

    Sildoja, Meelis-Mait; Nevas, Saulius; Kouremeti, Natalia; Gröbner, Julian; Pape, Sven; Pendsa, Stefan; Sperfeld, Peter; Kemus, Fabian

    2018-06-01

    A compact and stable UV monitoring source based on state-of-the-art commercially available ultraviolet light emitting diodes (UV-LEDs) has been developed. It is designed to trace the radiometric stability—both responsivity and wavelength scale—of array spectroradiometers measuring direct solar irradiance in the wavelength range between 300 nm and 400 nm. The spectral irradiance stability of the UV-LED-based light source observed in the laboratory after seasoning (burning-in) the individual LEDs was better than 0.3% over a 12 h period of continuous operation. The integral irradiance measurements of the source over a period of several months, where the UV-LED source was not operated continuously between the measurements, showed stability within 0.3%. In-field measurements of the source with an array spectroradiometer indicated the stability of the source to be within the standard uncertainty of the spectroradiometer calibration, which was within 1% to 2%.

  11. PBMC and MDAMB-231 cellular viability after telecobalt irradiation

    International Nuclear Information System (INIS)

    Andrade, Lidia M.; Campos, Tarcisio P.R.

    2002-01-01

    Radiotherapy by gamma rays are used for cancer treatment. Ionizing radiation effects on cells has been investigated. Studies in vitro were developed using tumor cell lines and ionizing radiation. The aim of this research was to test the cellular viability response of two cell types through MTT assay: human peripheral blood mononuclear cell (PBMC) and human breast carcinoma cell line MDAMB-231. These cells were irradiated with 60 Co source Theratron 80 radiotherapy machine from Atomic Energy Canada Limited with 20 x 20 cm field at 136.4 cGy/min, surface source distance 70 cm. Culture flasks contained 10 4 , 10 5 and 10 6 cells were irradiated with 100 Gy, 25 Gy, and 50 Gy using non fractionated doses. Cellular viability were evaluated 1h, 24h, 48h and 72h after irradiation and samples were measured by optical density at 595nm. Our results show that PBMC cells present lower cellular viability post irradiation. On the other hand, MDAMB-231 cells maintain viability after 50 Gy irradiation at 72h indicating cellular radioresistance. (author)

  12. Detection of garlic gamma-irradiated by assay comet

    Energy Technology Data Exchange (ETDEWEB)

    Moreno Alvarez, Damaris L.; Miranda, Enrique F. Prieto; Carro, Sandra; Iglesias Enrique, Isora; Matos, Wilberto [Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear (CEADEN), Ciudad de La Habana (Cuba)], e-mail: damaris@ceaden.edu.cu

    2009-07-01

    The garlic samples were irradiated in a facility with {sup 60}Co sources, at absorbed dose values of 0-0,15 kGy. The detection method utilized for the identification of the irradiated garlic was biological comet assay. The samples were classified post-irradiation several times. The irradiated samples showed high strand breaks of DNA exhibiting comets of several forms, while the not irradiated and lower dose samples showed a behavior like round shape and light comets. Significant differences were found for higher absorbed dose values at 0.06 kGy, this absorbed dose value is corresponding with the applied dose value at this food in order to avoid the germination. (author)

  13. Gamma greenhouse for chronic irradiation in plant mutation breeding

    International Nuclear Information System (INIS)

    Azhar Mohamad; Rusli Ibrahim; Sobri Hussein

    2009-01-01

    The gamma greenhouse makes use of chronic irradiation from a 137 Cs source (double encapsulated 800 Ci caesium-137 pencil) producing a low dose rate, which is considered to be more effective in recovering and producing useful mutants in comparison to acute irradiation. The irradiation facility comprises an open topped irradiation area 30 m in diameter, protected by a partial concrete wall with entry maze and site topography. For safety, the facility is protected by a sophisticated interlock system, which only allows the source to be exposed when all the prerequisite safety conditions are met, and automatically returns the source to the safe storage position if any safety device is compromised. The main irradiation area is further protected by a 300 m diameter exclusion zone that is also protected by the safety interlock circuit. The facility can accommodate a wide range of plant materials such as seeds, seedlings in pots, cuttings, callus, somatic embryos and suspension cell cultures. Plant samples will be exposed to low dose gamma radiation over long periods of time (hours, weeks, months), depending on their nature and sensitivity. There was evidence whereby exposure of tissue culture materials to continuous low dose gamma irradiation resulting in considerably elevated somaclonal variation frequency without negative effects on culture response. It is not surprising that in vitro culture generating somaclonal variation together with in vitro mutagenesis inducing mutation lead to a higher variation frequency due to possible addition of mutagenic effect by in vitro mutagenesis to somaclonal variability arising from in vitro culture as well as the interaction between them. (Author)

  14. Simulating 60 Co gamma irradiation systems

    International Nuclear Information System (INIS)

    Omi, Nelson M.; Rela, Paulo R.

    2000-01-01

    The use of Cadgamma, a software dedicated to simulate 60 Co gamma irradiation systems, can lead to an optimized process and simulating, in a few hours, many configurations setups for the irradiation elements. The software can also simulate changes in the path of the product and the influence of any steady body like the support of the product support and source shoulders. These simulations minimize the number of dose mapping tests in industrial applications and allow the study of unusual setups. Cadgamma was developed at IPEN to simulate it is multipurpose 60 Co irradiation system, under construction and planned to be operating by the second half of 2001. The software was used on project stage and will help to optimize the irradiation process for each product to be treated. (author)

  15. Profitability of irradiation plants

    International Nuclear Information System (INIS)

    Bustos R, M.E.; Gonzalez F, C.; Liceaga C, G.; Ortiz A, G.

    1997-01-01

    In any industrial process it is seek an attractive profit from the contractor and the social points of view. The use of the irradiation technology in foods allows keep their hygienically, which aid to food supply without risks for health, an increment of new markets and a losses reduction. In other products -cosmetics or disposable for medical use- which are sterilized by irradiation, this process allows their secure use by the consumers. The investment cost of an irradiation plant depends mainly of the plant size and the radioactive material reload that principally is Cobalt 60, these two parameters are in function of the type of products for irradiation and the selected doses. In this work it is presented the economic calculus and the financial costs for different products and capacities of plants. In general terms is determined an adequate utility that indicates that this process is profitable. According to the economic and commercial conditions in the country were considered two types of credits for the financing of this projects. One utilizing International credit resources and other with national sources. (Author)

  16. Ultraviolet irradiation of maize (Zea Mays L.) pollen grains. Pt. 2

    International Nuclear Information System (INIS)

    Pfahler, P.L.; Linskens, H.F.

    1977-01-01

    Mature pollen grains from two single cross (F 1 ) hybrids, Wf9 x H55 and K64 x K55, were exposed to eleven levels (0 to 6.80 erg/cm 2 x 10 5 at 0.68 intervals) of ultraviolet irradiation and then were used to pollinate their source. Height and kernel characteristics (kernel weight, weight/100 kernels, kernel number) of individual F 2 plants produced by the normal F 2 kernels obtained from these pollinations were measured within each level and population. Highly significant exposure x population interactions were found for all characters, indicating that the effect of irradiation depended on the genetic source of the pollen grains. Increasing exposure increased or did not change the mean of Wf9 x H55 and decreased the mean in K64 x K55 for all characters. For coefficient of variation values, the interaction, exposure x population, was not significant for any character measured, indicating that irradiation-induced variability was unrelated to pollen source. The results indicate that pollen source strongly influenced the effect of ultraviolet irradiation on plant means but had no influence on variability. (orig.) [de

  17. Electromechanical engineering aspects of irradiator design

    International Nuclear Information System (INIS)

    Etienne, J.C.; Buyle, R.

    1984-01-01

    IRE, Institut National des Radioelements at Fleurus, has been irradiating foodstuffs since 1979. The steadily-increasing demands of the food industry led IRE to design and install a second, different type of irradiator. Selection criteria for choosing between the different alternatives or possibilities are given based on the primary consideration that a contract food irradiator must be able to provide a service in accordance with the requirements of his customers. The principal components - the radiation source geometry, the transport system and the control systems - are described. The choice of the major electromechanical components is discussed taking into account their susceptibility to radiation damage. (author)

  18. Creation of a plant for gamma-sterilization of the medical equipment and irradiation of industrial materials

    International Nuclear Information System (INIS)

    Maltceva, F.; Petukhov, V.; Chekushin, A.

    1996-01-01

    The purpose of the project. To create a powerful irradiation devices allowing to fulfill the irradiation of large-sized objects with dozes up to 4 Rad, and caring out the irradiation technologies by using of it. The basic tasks of the project and sequence of fulfillment. The realization of irradiating technologies is possible at WWR-K research reactor that is located near of Almaty . At the reactor complex, there are the means for creation powerful irradiating devices, and quite qualified personnel having the experience of works with radioactive materials is available. All of it allows, both for the staff and for the population living nearby, to have the radiation safety during of caring out of the work with the use of high intensive radioactive sources. Technical problems. The creation of plant has the following stages: - fulfilling of the calculation and design work; - caring out of mechanical works on manufacturing the irradiating devices, cartridges for irradiating sources and a hermetic tank for irradiated objects; - installation of devices, fulfilling of the tests; - purchasing or manufacturing of radioactive sources (-10-60); - loading of the sources into devices, and realization of measurements of the fields of gamma field inside the container; - making up the working instruction; - training of the personnel

  19. Dose rate determinations in the Portuguese Gamma Irradiation Facility: Monte Carlo simulations and measurements

    International Nuclear Information System (INIS)

    Oliveira, C.; Salgado, J.; Ferro de Carvalho, A.

    2000-01-01

    A simulation study of the Portuguese Gamma Irradiation Facility, UTR, has been carried out using the MCNP code. The work focused on the optimisation of the dose distribution inside the irradiation cell, dose calculations inside irradiated samples and dose calculations in critical points for protection purposes. Calculations were carried out at points inside and outside the irradiation cell, where different behaviour was expected (distance from the source, radiation absorption and scattering in irradiator structure and walls). The contributions from source, irradiator structure, sample material, carriers, walls, ceiling and floor to the photon spectra and air kerma at those points are reported and discussed. Air kerma measurements were also carried out using an ionisation chamber. Good agreement was found between experimental and calculated air kermas. (author)

  20. Is irradiation of food stuffs safe?

    International Nuclear Information System (INIS)

    Maheshwari, Raaz K.; Yadav, Rajesh K.

    2014-01-01

    Many advanced and several developing countries have abundant supplies of fresh, safe and nutritious food stuffs. Yet, despite the many precautions and processes in place to ensure safe food supply, microbial contamination is still a concern. There are a number of food processing tools available that provide additional protection for the food we consume. One very promising tool is food irradiation, which is a process of imparting ionizing energy to food to kill microorganisms. Food irradiation is the process of exposing food to a controlled source of ionising radiation for the purposes of reduction of microbial Ioad, destruction of pathogens, extension of product shelf life, and/or disinfection of produce. The term irradiation often evokes fears of nuclear radioactivity and cancer among consumers. The process seems frightening because it is powerful and invisible. Consequently questions and concerns exist particularly about the safety or wholesomeness of irradiated food. The paper highlights food irradiation as a food safety measure and the issues of concerns for consumers. (author)

  1. A simple and efficient gamma irradiator for RVNRL

    Energy Technology Data Exchange (ETDEWEB)

    Smolko, E; Ferenaz, G; Docters, E [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Makuuchi, Keizo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-12-31

    This work describes a new design of a gamma irradiator for RVNRL which obeys a reliable operation and an efficient economical equation. Our irradiator is of a nobel design according to present requirements of latex industries and to the state of the art of radiation technology. The irradiator is of a wet storage type, where the radioactive sources are fixed in the reactor vessel, permanently submerged in deionized water. Preformulated latex is pumped from a deposited vessel into the reactor vessel and it is recirculated during the irradiation cycle avoiding turbulences and dose inhomogeneities. The irradiation time per one ton batch with a Co-60 charge of 3.5E15 Bq (100 kCi) is of approximately 4 hours

  2. A simple and efficient gamma irradiator for RVNRL

    International Nuclear Information System (INIS)

    Smolko, E.; Ferenaz, G.; Docters, E.; Keizo Makuuchi

    1996-01-01

    This work describes a new design of a gamma irradiator for RVNRL which obeys a reliable operation and an efficient economical equation. Our irradiator is of a nobel design according to present requirements of latex industries and to the state of the art of radiation technology. The irradiator is of a wet storage type, where the radioactive sources are fixed in the reactor vessel, permanently submerged in deionized water. Preformulated latex is pumped from a deposited vessel into the reactor vessel and it is recirculated during the irradiation cycle avoiding turbulences and dose inhomogeneities. The irradiation time per one ton batch with a Co-60 charge of 3.5E15 Bq (100 kCi) is of approximately 4 hours

  3. Kraft cooking of gamma irradiated wood, (1)

    International Nuclear Information System (INIS)

    Inaba, Masamitsu; Meshitsuka, Gyosuke; Nakano, Junzo

    1979-01-01

    Studies have been made of kraft cooking of gamma irradiated wood. Beech (Fagus crenata Blume) wood meal suspended in aqueous alkaline alcohol was irradiated up to 1.5 KGy (0.15 Mrad) with gamma rays from a Co-60 source in the presence or absence of oxygen. The irradiated wood meals were washed thoroughly with fresh water, air dried and cooked under the ordinary cooking conditions. The results are summarized as follows: (1) Pre-irradiation in aqueous alkali have negligible effect on kraft cooking. (2) In the case of ethanol addition (50 g/l), pre-irradiation in vacuo shows acceleration of delignification and stabilization of carbohydrates during kraft cooking. Cooked yield gain by pre-irradiation was about 1.2% in all over the range of delignification from 80 to 90%. Aqueous ethanol without alkali also shows positive but smaller effect than that with alkali. (3) Propanol, iso-propanol and butanol show positive but smaller effects than ethanol. However, methanol does not show any positive effect. (4) Irradiation in the presence of oxygen does not show any attractive effect on kraft cooking. (author)

  4. Changes in lens following 60Co irradiation

    International Nuclear Information System (INIS)

    Rozsival, P.; Obenberger, J.; Sladkova, J.

    1985-01-01

    Chinchilla rabbit lenses were irradiated using a 60 Co gamma source, and the changes in the transport activities, native weight, water content and dry weight were observed. The heads of rabbits were irradiated with doses of 10 and 20 Gy and functional changes occurring in the lenses were studied till the twenty-fourth week after the irradiation. The weight of the rabbit lens irradiated with a dose of 20 Gy significantly increased after the twelfth week and was maximal 16 weeks after irradiation when also cataracts were observed. The increased weight of lenses was caused by accumulation of water. The decrease in the dry weight of lenses preceded the period of visible cataracts. A decreased uptake of rubidium occurring during in vitro cultivation of lenses was the most sensitive marker for the changes caused by 20 Gy irradiation. It was significantly decreased as early as 8 weeks after irradiation, preceding the increased hydration of lenses by 4 weeks and the presence of visible cataracts by as much as 8 weeks

  5. Radiation protection in category III large gamma irradiators

    International Nuclear Information System (INIS)

    Costa, Neivaldo; Furlan, Gilberto Ribeiro; Itepan, Natanael Marcio

    2011-01-01

    This article discusses the advantages of category III large gamma irradiator compared to the others, with emphasis on aspects of radiological protection, in the industrial sector. This category is a kind of irradiators almost unknown to the regulators authorities and the industrial community, despite its simple construction and greater radiation safety intrinsic to the model, able to maintain an efficiency of productivity comparable to those of category IV. Worldwide, there are installed more than 200 category IV irradiators and there is none of a category III irradiator in operation. In a category III gamma irradiator, the source remains fixed in the bottom of the tank, always shielded by water, negating the exposition risk. Taking into account the benefits in relation to radiation safety, the category III large irradiators are highly recommended for industrial, commercial purposes or scientific research. (author)

  6. Irradiated vaccines against bovine babesiosis

    International Nuclear Information System (INIS)

    Weilgama, D.J.; Weerasinghe, H.M.C.; Perera, P.S.G.; Perera, J.M.R.

    1988-01-01

    Experiments were conducted on non-splenectomized Bos taurus calves to determine the immunogenicity of blood vaccines containing either Babesia bigemina or Babesia bovis parasites irradiated in a 60 Co source. Groups of calves between 6 and 10 months of age, found to be free of previous babesial infections by serodiagnosis, were inoculated with B. bigemina ('G' isolate) irradiated at rates ranging from 350 to 500 Gy. These vaccines caused low to moderate reactions on primary inoculation which subsided without treatment. Parasites irradiated at 350 Gy produced a strong immunity against virulent homologous challenge. Vaccinated calves also withstood virulent heterologous B. bigemina ('H' isolate) and B. bovis ('A' isolate) challenges made 85 and 129 days later. It also became evident that the use of babesicides to control reactions should be avoided since early treatment of 'reactor' animals caused breakdown of immunity among vaccinates. B. bovis ('A' isolate) parasites irradiated at dose rates of either 300 Gy or 350 Gy caused mild to moderate reactions in immunized calves, with the reactions in the 300 Gy group being slightly more severe. On challenge with homologous parasites, animals that had previously been inoculated with organisms irradiated at 300 Gy showed better protection than those that had received parasites irradiated at 350 Gy. (author). 28 refs, 5 tabs

  7. Sensitivity of ice-nucleating bacteria to ultraviolet irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Obata, Hitoshi; Tanahashi, Shinji; Kawahara, Hidehisa (Kansai Univ., Suita, Osaka (Japan). Faculty of Engineering)

    1992-01-01

    The effect of ultraviolet (UV) irradiation on the ice-nucleating activity of the ice-nucleating bacteria was examined. Bacterial suspension was irradiated with UV (254 nm, 6Wx2) for 5 min at a distance of 20 cm from UV source. Although no viable cells were detected, the ice-nucreating activity of the cells was not affected. Furthermore, after UV irradiation for 3 hr, the ice-nucleating activity of Pseudomonas fluorescens and P. syringae was only slightly decreased, although that of P. viridiflava and Erwinia herbicola was significantly lowered. We succeeded in killing the ice-nucleating bacteria, while retaining their ice-nucleating activity with UV irradiation. (author).

  8. Irradiation plant for flowable material

    International Nuclear Information System (INIS)

    Bosshard, E.

    1975-01-01

    The irradiation plant can be used to treat various flowable materials including effluent or sewage sludge. The plant contains a concrete vessel in which a partition is mounted to form two coaxial irradiation chambers through which the flowable material can be circulated by means of an impeller. The partition can be formed to house tubes of radiation sources and to provide a venturi-like member about the impeller. The operation of the impeller is reversed periodically to assure movement of both heavy and light particles in the flow. (U.S.)

  9. In vivo evaluation of expression of TGFβ1 in the irradiated heart

    International Nuclear Information System (INIS)

    Affonso Junior, Renato Jose; Oshima, Celina Tizuko Fujiyama; Silva, Maria Regina Regis; Kimura, Edna Teruko; Egami, Mizue Imoto; Segreto, Roberto Araujo; Segreto, Helena Regina Comodo

    2004-01-01

    The objectives of this study were to assess the latent and active TGFβ1 localization in the heart, to evaluate whether or not radiation induces latent TGFβ1 activation, and to study the distribution of collagen fibers in the irradiated heart. Thirty-two C 57 BL mice were randomly assigned in two groups: GI (non irradiated animals) and GII (irradiated animals). The mice from G II received a single whole-body radiation dose of 7 Gy, using a 60 Co source at a dose rate of 0.97 Gy/min. The animals were sacrificed by cervical dislocation at 1, 14, 30 and 90 days after irradiation. The irradiated hearts showed: nuclear changes and muscle cells with decreased striations; significant increase in the collagen deposition 90 days after irradiation; latent TGFβ1 activation in the cardio myocytes and connective tissue cells after irradiation. Our results show the importance of TGFβ1 protein in the process of radiation-induced heart fibrosis and suggest that cardio myocytes and connective cells may play a role in this mechanism acting as cellular sources of active TGFβ1. (author)

  10. Fiscal year 1976 DT fusion neutron irradiations and dosimetry at the LLL rotating target neutron source

    International Nuclear Information System (INIS)

    MacLean, S.C.

    1977-01-01

    The DT fusion neutron irradiation of 319 samples during 19 irradiation periods (beam-on time of more than 1026 hours) is described. Experiments from 24 individuals representing 11 institutions are summarized. The numbers of the UCID dosimetry reports detailing each of the irradiations are given

  11. 78 FR 27303 - Irradiation in the Production, Processing, and Handling of Animal Feed and Pet Food; Electron...

    Science.gov (United States)

    2013-05-10

    ...-0178] Irradiation in the Production, Processing, and Handling of Animal Feed and Pet Food; Electron... electron beam and x-ray sources for irradiation of poultry feed and poultry feed ingredients. This action... CFR part 579) to provide for the safe use of electron beam and x-ray sources for irradiation of...

  12. Investigation of physical detection markers in irradiated foods under different radiation sources and post-irradiation storage conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Joong Ho; Kim, Gui Ran; Ahn, Jae Jun; Kim, Dong Gil; Jin, Qiong Wen; Park, Ju Hwan; Lee, Ji Hyun [Kyungpook National University, Daegu (Korea, Republic of)

    2010-04-15

    In PSL analysis, all unirradiated samples showed less than 700 (negative) photon counts (PCs). At 5 kGy, spice samples showed PCs in range of 700-5,000 (intermediate), while grains, legumes, root-crops, and seasonings samples showed PCs over 5,000 (positive). This PSL based-detection of radiation treatment was possible even after 24 months of storage. In TL analysis, TL glow curve was characteristically different between unirradiated and irradiated samples. Glow curves were observed in temperature ranges of 150-250 .deg. C for irradiated and over 300 .deg. C for unirradiated samples. TL ratio (TL{sub 1}/TL{sub 2}) provided valuable additional confirmations as unirradiated sample showed values less than 0.1, while irradiated sample showed more than 0.1. However, with storage time, TL intensity and TL ratio decreased but discrimination was still possible even after storage of 24 months. Samples stored at room temperature with exposure to direct or indirect light enhanced the mentioned decrease of TL intensity and TL ratio as compared to low temperature storage in dark room. In ESR analysis, legumes and spices showed radiation-induced cellulose radicals, while seasonings showed multi-component signals of radiation-induced crystalline sugar radical. These radiation-induced radicals could be potential markers for the detection of radiation treatments in subjected samples. The decreasing trend was also found for radiation-specific ESR signals of cellulose and crystalline sugar radicals during storage. However, radiation-induced radicals in legumes, powdered pepper and seasonings were detectable even after 6 months of storage

  13. Food irradiation: a reply to the food industry; and reply

    International Nuclear Information System (INIS)

    Brynjolfsson, Ari; Piccioni, R.

    1989-01-01

    In a reply to a critical article on food irradiation, Dr Ari Brynjolfsson of the International Facility of Food Irradiation Technology contends that the food industry has no interest in supporting the nuclear industry by using nuclear wastes as radiation sources - high voltage electron generators are more practical and economic. Also World Health Organization Toxicologists have concluded irradiated food is safe toxicologically, nutritionally and microbiologically. A study in India found no difference in polyploidy in children fed irradiated or non-irradiated food. In reply Dr Richard Piccioni suggests that the cancer risk from irradiated food is high, that the Indian study showed that irradiated food can cause an increase in polyploidy in well-fed adults, and suggests that Cs-137 from nuclear reactors will be used in food irradiation. (U.K.)

  14. Fabrication and mount of a multisource irradiation systems

    International Nuclear Information System (INIS)

    Mariano-Heredia, E.

    1990-01-01

    Conception of this equipment was born of the necessity for a system suitalbe for optimizing the methods employed up to the present in ININ, for calibrating portalbe gamma radiation monitors for radiological protection of the need for a national level reference laboratory. The equipment parts are: a multisource irradiator, a system for the transport and positioning of radiation monitors, an aerial conveyor ANS a control panel. The multisource irradiator, which is shielded container, houses five Cs-137 and Co-60 different activity radiative sources. The transport and positioning radiation monitor system places the monitors for calibration at the required distance and height. The instrument source distance can be selected from the control panel. The instrument source distance and detector readings can be verified by means of a closed TV circuit. The activity of the radiation sources, using varying combinations of instrument source distances, has been characterized for each of the radiative sources and all the calibration parameters of the radiation beam central axis are known to a precision of within 3.0 % error. (Author)

  15. Effectiveness of thermoluminescence analysis to detect low quantity of gamma-irradiated component in non-irradiated mushroom powders

    International Nuclear Information System (INIS)

    Akram, Kashif; Ahn, Jae-Jun; Shahbaz, Hafiz Muhammad; Jo, Deokjo; Kwon, Joong-Ho

    2013-01-01

    Gamma-irradiated (0–10 kGy) dried mushrooms (Lentinus edodes) powders were mixed at different ratios (1–10%) in the non-irradiated samples and investigated using photostimulated-luminescence (PSL), electron spin resonance (ESR) and thermoluminescence (TL) techniques. The PSL results were negative for all samples at 1% mixing ratio, whereas intermediate results were observed for the samples containing 5% or 10% irradiated component with the exception (positive) of 10% mixing of 10 kGy-irradiated sample. The ESR analysis showed the presence of crystalline sugar radicals in the irradiated samples but the radiation-specific spectral features were absent in the mixed samples. TL analysis showed the radiation-specific TL glow curves; however, the complicated results were observed at 1% mixing of 2 and 5 kGy-irradiated samples, which required careful evaluations to draw the final conclusion about the irradiation status of the samples. TL ratios could only confirm the results of samples with 5% and 10% mixing of 10 kGy, and 10% mixing of 5 kGy-irradiated components. SEM-EDX analysis showed that feldspar and quartz were major contaminating minerals, responsible for the radiation-specific luminescence characteristics. -- Highlights: ► Detection of irradiated food is important to enforce the applied regulations. ► The effectiveness of TL analysis was investigated to detect irradiated component. ► The TL results were compared with those from PSL and ESR analysis. ► TL analysis was most effective to characterize the irradiation status of samples. ► SEM-EDX analysis showed feldspar and quartz as the main source of TL properties

  16. Effectiveness of thermoluminescence analysis to detect low quantity of gamma-irradiated component in non-irradiated mushroom powders

    Energy Technology Data Exchange (ETDEWEB)

    Akram, Kashif [School of Food Science and Biotechnology, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Institute of Food Science and Nutrition, University of Sargodha, Sargodha 40100 (Pakistan); Ahn, Jae-Jun [School of Food Science and Biotechnology, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Shahbaz, Hafiz Muhammad [School of Food Science and Biotechnology, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Institute of Food Science and Nutrition, University of Sargodha, Sargodha 40100 (Pakistan); Jo, Deokjo [School of Food Science and Biotechnology, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kwon, Joong-Ho, E-mail: jhkwon@knu.ac.kr [School of Food Science and Biotechnology, Kyungpook National University, Daegu 702-701 (Korea, Republic of)

    2013-04-15

    Gamma-irradiated (0–10 kGy) dried mushrooms (Lentinus edodes) powders were mixed at different ratios (1–10%) in the non-irradiated samples and investigated using photostimulated-luminescence (PSL), electron spin resonance (ESR) and thermoluminescence (TL) techniques. The PSL results were negative for all samples at 1% mixing ratio, whereas intermediate results were observed for the samples containing 5% or 10% irradiated component with the exception (positive) of 10% mixing of 10 kGy-irradiated sample. The ESR analysis showed the presence of crystalline sugar radicals in the irradiated samples but the radiation-specific spectral features were absent in the mixed samples. TL analysis showed the radiation-specific TL glow curves; however, the complicated results were observed at 1% mixing of 2 and 5 kGy-irradiated samples, which required careful evaluations to draw the final conclusion about the irradiation status of the samples. TL ratios could only confirm the results of samples with 5% and 10% mixing of 10 kGy, and 10% mixing of 5 kGy-irradiated components. SEM-EDX analysis showed that feldspar and quartz were major contaminating minerals, responsible for the radiation-specific luminescence characteristics. -- Highlights: ► Detection of irradiated food is important to enforce the applied regulations. ► The effectiveness of TL analysis was investigated to detect irradiated component. ► The TL results were compared with those from PSL and ESR analysis. ► TL analysis was most effective to characterize the irradiation status of samples. ► SEM-EDX analysis showed feldspar and quartz as the main source of TL properties.

  17. UV radiation emitted by selected sources at work stands

    International Nuclear Information System (INIS)

    Kozlowski, C.

    2001-01-01

    The paper presents the results of UV effective irradiance measurements at work stands for sources such as: welding arcs, gas blowpipes, exposure processes, printing machines and insecticide lamps. The irradiance measurements were performed using broad-band instruments with detector heads corrected to the Polish action spectra (erythematous and conjunctivitis). The obtained values of effective irradiance for above sources ranged from 0.2 to 8000 mW/m2. Safe exposure time corresponding to irradiance was calculated for the Polish threshold limit values. For welding processes the spectra of selected welding arcs are presented additionally. These spectra were measured using a fiber-optic spectrometer. (author)

  18. Preparation of 114mIn low energy conversion electron sources

    International Nuclear Information System (INIS)

    Wrede, C.; Filippone, B.W.; Garcia, A.; Harper, G.C.; Lassell, S.; Liu, J.; Mendenhall, M.P.; Palmer, A.S.C.; Pattie, R.W.; Will, D.I.; Young, A.R.

    2011-01-01

    Highlights: → Controlled ion implantation of In-113 into thin Al substrate. → Production of In-114m (half life = 50 days) by neutron irradiation. → Use of In-114m as a source of electron lines and continuum for calibrations. → Source reactivation by short neutron irradiation. -- Abstract: The preparation of 114m In sources of conversion electrons in the energy range 162-190 keV and β continuum with a 1989 keV endpoint via ion implantation of 113 In into Al substrates and subsequent irradiation by thermal and epi-thermal neutrons in a nuclear reactor is described.

  19. A Practical Irradiance Model for Bifacial PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill; MacAlpine, Sara; Deline, Chris; Asgharzadeh, Amir; Toor, Fatima; Riley, Daniel; Stein, Joshua; Hansen, Clifford

    2017-06-15

    A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors (CFs) to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-of-incidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using the RADIANCE ray tracing program.

  20. The effect of irradiation dose and age of bird on the ESR signal in irradiated chicken drumsticks

    International Nuclear Information System (INIS)

    Gray, R.; Stevenson, M.H.; Kilpatrick, D.J.

    1990-01-01

    Groups of 20 broiler chickens of the same genetic strain and reared under identical conditions were slaughtered at either 4, 5, 6, 7 or 8 weeks of age. Pairs of drumsticks were removed from each bird and groups were either not irradiated or irradiated at 2.5, 5.0, 7.5 or 10.0 kGy using a cobalt 60 source. Bone samples were excised, fragmented, freeze dried and ground prior to the determination of free radical concentration using electron spin resonance (ESR) spectroscopy. Increasing irradiation dose gave a highly significant increase in free radical concentration whilst for each irradiation dose, bones from younger birds gave significantly lower concentrations compared to those for older birds. Crystallinity coefficient increased linearly with age of bird and this may account in part for the increased signal observed as the birds aged. (author)

  1. Nanodefect formation in LiF crystals under gamma irradiation

    International Nuclear Information System (INIS)

    Mussaeva, M.A.; Ibragimova, Eh.M.; Kalanov, M.U.; Muminov, M.I.

    2006-01-01

    One studied the spectra of absorption and of photoluminescence, microhardness and performed X-ray structure analysis of gamma-irradiated LiF crystals in a shutdown reactor and in 60 Co source when gamma-radiation dose rate was equal to 7.65 Gy/s. In addition to formation of point and combined radiation defects one detected the presence of the gamma-irradiation induced 28 nm size nanoparticles of LiOH phase in Li sublattice. Formation of defects is shown to occur more efficiently in a shutdown reactor in contrast to 60 Co source [ru

  2. Can prenatal low-dose irradiation affect behavior of adult rats?

    International Nuclear Information System (INIS)

    Smajda, B.; Tomasova, L.; Kokocova, N.

    2011-01-01

    The aim of our study was to determine whether exposure of very low dose gamma-rays during the critical phase of brain development affects some selected behavioral parameters in adult rats. Pregnant female Wistar rats were irradiated with 1 Gy gamma-rays from a cobalt source at 17 th day of pregnancy. The progeniture of irradiated as well as non-irradiated females have undergone behavioral tests at the age of 3 months. Irradiated animals exhibited lower locomotor and exploratory activity in the open field test. (authors)

  3. Performance of irradiated CVD diamond micro-strip sensors

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S.V.; Thomson, G.B.

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15 /cm 2 ) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2x10 15 p/cm 2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9x10 15 π/cm 2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations

  4. Performance of irradiated CVD diamond micro-strip sensors

    Science.gov (United States)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; mac Lynne, L.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L. S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J. L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A. M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S. V.; Thomson, G. B.

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a β-source and the performance before and after intense (>10 15/cm 2) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2×10 15 p/ cm2 lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9×10 15 π/ cm2 lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  5. Alternative method of portable irradiation of manganese sulphate solution by an plutonium-beryllium source for manganese sulphate bath efficiency measurements

    International Nuclear Information System (INIS)

    Silva, Fellipe Souza da; Martins, Marcelo Marques; Pereira, Walsan Wagner

    2016-01-01

    This study intends to create an alternative irradiation system from a Plutonium-Beryllium source for manganese sulphate solution using the Monte Carlo code. Thus seeking to eliminate the issue of institutes that do not have reactors or particle accelerators in its infrastructure, in order to optimize and provide independence for them to carry out efficiency measurements of MnSO_4 solution in their own locality. The Monte Carlo simulations defined the technical features of this new system so that the solution reaches the maximum neutron capture by manganese in solution. (author)

  6. A neutron irradiator applied to cancer treatment

    International Nuclear Information System (INIS)

    Campos, Tarcisio P.R.; Andrade, Ana P. de

    2000-01-01

    Cancer and the way of treating it with neutron capture therapy are addressed. This paper discusses also the type of neutron facilities used to treat cancer around the world, as follow: discrete neutron sources, accelerators, and nuclear reactors. The major features of an epithermal neutron irradiation facility applied to BNCT treatment are addressed. The main goal is to give another choice of neutron irradiators to be set in a hospital. The irradiation facility embeds a set of 252 Cf neutron source coupled with a homogeneous mixture of uranium-zirconium hydride alloy containing 8.4 wt % uranium enriched to 20% U 235 . The facility delivers an epithermal neutron beam with low background of fast neutron and gamma rays. The N particle transport code (MCNP-4A) has been used during the simulation in order to achieve the desired configurations and to estimate the multiplication factor, k eff . The present facility loaded with 30 mg of 252 Cf neutron source generates an external beam with an intensity of 10 7 n/cm 2 .s on the spectrum of 4 eV to 40 KeV. The 252 Cf - facility coupled with fissile material was able to amplify the epithermal flux to 10 8 n/cm 2 .s, maintaining the figure-of-merits represented by the ratios of the fast dose and gamma dose in air per epithermal neutron flux closed to those values presented by BMRR, MITR-II and Petten Reactor. The medical irradiation facility loaded with 252 Cf- 235 U can be a choice for BNCT. (author)

  7. Model of the dose rate for a semi industrial irradiation plant. Pt. 2

    International Nuclear Information System (INIS)

    Mangusi, Josefina

    2004-01-01

    The second stage of the model for the absorbed dose rate in air for the enclosure of a half-industrialist irradiation plant operating with cobalt-60 sources holden in plan geometry is presented. The sensibility of the model with the treatment of the support structure of the irradiator is analyzed and verified with experimental measurements with good accord. The model of the absorbed dose rate in air in the case of an interposed material between the radioactive sources and the point of interest includes in its calculation a set of secondary radioactive sources created by the Compton scattering of the primary radiation. The accord of the calculated absorbed dose rate and the experimental measured ones is good. The transit dose due to the irradiator moving until its dwell position is also modeled. The isodose curves for a set of irradiator parallel planes are also generated. (author) [es

  8. Safety issues in the handling of radiation sources in category IV gamma radiation facilities

    International Nuclear Information System (INIS)

    Kohli, A.K.

    2002-01-01

    There is potential for incidents/accidents related to handling of radiation sources. This is increasing due to the fact that more number of plants that too with much larger levels of activity are now coming up. Such facilities produce very high levels of exposure rates during irradiation. A person accidentally present in the irradiation cell can receive a lethal dose within a very short time. Apart from safety requirements during operation and maintenance of these facilities, safety during loading and unloading of sources is important. Category IV type irradiators are the most common. Doubly encapsulated Co-60 slugs are employed to form the source pencils. These irradiators employ a water pool for safely storing the source pencils when irradiation of the products is not going on or when human access is needed into the irradiation cell for some maintenance or source loading/unloading operations. Safety during loading/unloading operations of source pencils is important. In design itself care needs to be taken such that all such operations are convenient and any incident will not lead to a situation where it becomes difficult to come out. Different situations, which can arise during handling of radiation sources and suggested designs to obviate such tight situations, are discussed. (Author)

  9. Beneficial uses program. Progress report ending December 31, 1978. [Irradiated sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    1979-03-01

    The Beneficial Uses Program is a comprehensive program to develop the necessary technologies for cost-beneficial uses of existing and future surplus radioactive materials. The major portion of the work at Sandia is concentrated in two sub-programs: The Waste Resources Utilization Program and the Separation Technology and Source Development Program. Progress is reported on: (1) the Sandia Irradiator for Dried Sewage Sludge; (2) bacteriology; (3) mycology; (4) virology; (5) animal feeds containing irradiated sewage solids; (6) use of irradiated sewage sludge as fertilizer; and (7) development of /sup 90/Sr and /sup 137/Cs radiation sources obtained from radioactive wastes. (TFD)

  10. Preliminary examination of induced radioactivity in pepper by 10 MeV electron irradiation

    International Nuclear Information System (INIS)

    Katayama, Tadashi; Furuta, Masakazu; Sibata, Setsuko; Ito, Norio; Mizohata, Akira; Matsunami, Tadao; Toratani, Hirokazu; Takeda, Atsuhiko.

    1991-01-01

    β-ray measurement was performed on 10 MeV electron-irradiated black pepper and white pepper with liquid scintillation counter in order to reconfirm the wholesomeness of irradiated foods and present unambiguous data to general consumers concerning about the induced radioactivity in the irradiated foods. In irradiated black pepper no radioactivity other than from natural source, un-irradiated one, was detected. But in irradiated white pepper, it was suggested that induced radioactivity might be detected if the detection method was more improved. (author)

  11. Dosimetry of blood irradiator - 2000

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.; Shinde, S.H.; Bhat, R.M.; Rao, Suresh; Sharma, D.N.

    2008-01-01

    Full text: Blood transfusion to an immunodeficient or immunosuppressed patient has a high risk involved due to occurrence of Transfusion Graft Versus Host Disease (T-GVHD). In order to eliminate this problem, blood is routinely exposed to ionizing radiation (gamma) prior to transfusion. Doses ranging from 15 Gy to 50 Gy can prevent T-GVHD. Aim of the present work was to perform dosimetry of 60 Co Blood Irradiator-2000 developed by Board of Radiation and isotope Technology (BRIT), India; using FBX dosimetric system. Dose-rate measured by FBX dosimeter was intercompared with Fricke dosimeter, which is a Reference Standard dosimeter. Experiments included measurement of dose-rate at the centre of irradiation volume, dose mapping in the central vertical plane within the irradiation volume and measurement of average dose received by blood sample using blood bags filled with FBX dosimeter by simulating actual irradiation conditions. During irradiation, the sample chamber is retracted into a cylindrical source cage, so that the sample is irradiated from all sides uniformly. Blood irradiator-2000 has sample rotation facility for increasing the dose uniformity during irradiation. The performance of this was investigated by measuring the central vertical plane dose profile in stationary state as well in rotation using the sample rotation facility (60 rpm). FBX being an aqueous dosimetric system fills container of irregular shape being irradiated hence can be used to integrate the dose over the volume. Dose-rate measured by FBX dosimeter was intercompared with Fricke dosimeter, which was in good agreement. Average dose-rate at the centre of irradiation volume and within the blood bag was measured by FBX and Fricke dosimeters. It was observed that dose profiles measured by FBX and Fricke dosimeters agreed within ± 2%. Dose uniformity within the irradiation volume was found to reduce from 21% to 17% when the sample rotation facility was used. Thus, it is suggested by the

  12. Gemstone enhancing dedicated gamma irradiator development; Desenvolvimento de irradiador gama dedicado ao beneficiamento de pedras preciosas

    Energy Technology Data Exchange (ETDEWEB)

    Omi, Nelson Minoru

    2006-07-01

    The gemstones gamma irradiation process to enhance the color is widely accepted for the jewelry industry. These gems are processed in conventional industrial gamma irradiation plant which are optimized for other purposes, using underwater irradiation devices with high rejection rate due to it's poor dose uniformity. A new conception design, which states the working principles and manufacturing ways of the device, was developed in this work. The suggested device's design is based on the rotation of cylindrical baskets and their translation in circular paths inside and outside a cylindrical source rack as a planetary system. The device is meant to perform the irradiation in the bottom of the source storage pool, where the sources remain always shielded by the water layer. The irradiator matches the Category III IAEA classification. To verify the physical viability of the basic principle, tests with rotating cylindrical baskets were performed in the Multipurpose Irradiator raised in the CTR, IPEN. Also, simulations using the CADGAMMA software, adapted to simulate underwater irradiations were performed. With the definitive irradiator, the irradiation quality will be enhanced with better dose control and the production costs will be significantly lower than market prices due to the intended treatment device's optimization. (author)

  13. Effect of ion irradiation-produced defects on the mobility of dislocations in 304 stainless steel

    International Nuclear Information System (INIS)

    Briceno, M.; Fenske, J.; Dadfarnia, M.; Sofronis, P.; Robertson, I.M.

    2011-01-01

    The impact of heavy-ion produced defects on the mobility of dislocations, dislocation sources and newly generated dislocations in 304 stainless steel are discovered by performing irradiation and deformation experiments in real time in the transmission electron microscope. Dislocations mobile prior to the irradiation are effectively locked in position by the irradiation, but the irradiation has no discernible impact on the ability of a source to generate dislocations. The motion and mobility of a dislocation is altered by the irradiation. It becomes irregular and jerky and the mobility increases slowly with time as the radiation-produced defects are annihilated locally. Channels created by dislocations ejected from grain boundary dislocation sources were found to have a natural width, as the emission sites within the boundary were spaced close together. Finally, the distribution of dislocations, basically, an inverse dislocation pile-up, within a cleared channel suggests a new mechanism for generating high local levels of stress at grain boundaries. The impact of these observations on the mechanical properties of irradiated materials is discussed briefly.

  14. Effect of ion irradiation-produced defects on the mobility of dislocations in 304 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Briceno, M.; Fenske, J. [Department of Materials Science and Engineering, University of Illinois, Urbana, IL 61801 (United States); Dadfarnia, M.; Sofronis, P. [Department of Mechanical Science and Engineering, University of Illinois, Urbana, IL 61801 (United States); Robertson, I.M., E-mail: ian.robertson@tcd.ie [Department of Materials Science and Engineering, University of Illinois, Urbana, IL 61801 (United States)

    2011-02-01

    The impact of heavy-ion produced defects on the mobility of dislocations, dislocation sources and newly generated dislocations in 304 stainless steel are discovered by performing irradiation and deformation experiments in real time in the transmission electron microscope. Dislocations mobile prior to the irradiation are effectively locked in position by the irradiation, but the irradiation has no discernible impact on the ability of a source to generate dislocations. The motion and mobility of a dislocation is altered by the irradiation. It becomes irregular and jerky and the mobility increases slowly with time as the radiation-produced defects are annihilated locally. Channels created by dislocations ejected from grain boundary dislocation sources were found to have a natural width, as the emission sites within the boundary were spaced close together. Finally, the distribution of dislocations, basically, an inverse dislocation pile-up, within a cleared channel suggests a new mechanism for generating high local levels of stress at grain boundaries. The impact of these observations on the mechanical properties of irradiated materials is discussed briefly.

  15. PVIS-4, Pressure vessel irradiation, source preparation

    International Nuclear Information System (INIS)

    Wasastjerna, Frej

    2003-01-01

    1 - Description of program or function: The program prepares a fixed neutron source distribution in radial, (r,θ), (r,z) or (r,θ,z) geometry for ANISN, DORT or TORT. The user can input the source distribution in some relatively compact form (typically a few variables defining the spectrum, 10 values for the axial source distribution and, for the horizontal distribution, the values at the center and corners of each of the outermost fuel bundles and the average value for each interior bundle). The program then creates the required source arrays, such as 96*, 97* and 98* arrays for DORT. 2 - Methods: Each required operation is performed by a separate module (a set of subprograms). HORIHX or HORISQ takes a source distribution in the transverse plane, given at the center and corners of each fuel bundle in hexagonal or square geometry, and transforms it into (r,θ) or radial geometry. In the latter case, the output distribution may be averaged in the azimuthal direction or azimuthal maxima may be obtained. FOUR takes an axial distribution, specified as a histogram, and approximates this with a Fourier series. This is then used to obtain a histogram distribution for a different axial mesh. SQPIN takes a 3-D pin-wise distribution in square geometry and transforms it into a radial, (r,θ), (r,z) or (r,θ,z) distribution. FISPEC calculates a group-wise energy spectrum from any of several different functional forms. Several components with different forms may be combined into one spectrum. COMBI combines the space and energy distributions prepared by the other modules and presents the result in a format appropriate for the SN programs in the DOORS system. 3 - Restrictions on the complexity of the problem: At present a reactor core of hexagonal fuel bundles must have 30- or 60-degree symmetry, a core of square bundles must have 45- or 90-degree symmetry (except if the sq-pin option is used). Other core geometries are not supported for the input distribution. Only cylindrical

  16. Radionuclide and electric accelerator sources for food irradiation

    International Nuclear Information System (INIS)

    Lagunas-Solar, M.C.; Matthews, S.M.

    1985-01-01

    Radiation processing of food requires radiation sources with high intensity, penetrability, reliability, and the flexibility to be adapted to current food processing techniques. Current proposed regulations limit the radiation sources which can be utilized to radionuclides or electrically-driven accelerators. Therefore, the power, throughput, and use efficiency of these sources are important factors affecting the design, installation, operation, and economics of large-scale food-processing facilities. An analysis of the advantages and disadvantages of these sources is presented here, with special attention to the current status of both technologies, and with emphasis on the needs of the food-processing industry. (author)

  17. Development of a training programme for radiation protection officers in industrial irradiators

    International Nuclear Information System (INIS)

    Mumuni, I. I.

    2014-01-01

    The International Basic Safety Standards (BSS) for Protection against Ionizing Radiation and for the Safety of Radiation Sources establish the basic requirements for protection against the risks associated with exposure to ionizing radiation and for the safety of radiation sources that may deliver such exposure. One important aspect of the Safety Standard is education and training of all personnel involved in the activities of radiation and radioactive sources. According to the BSS a Radiation Protection Officer is an individual technically competent in radiation protection matters relevant for a given type of practice who is designated by the registrant or licensee to oversee the application of the requirements of the standards. By this assigned role, radiation protection officers for industrial irradiators should be adequately trained since these facilities involve very high dose rates during irradiation, such that a person accidentally exposed can receive a lethal dose within minutes or seconds and fatalities can occur. This training among others things will enable the radiation protection officers to understand practical application of the IAEA Safety Standard to industrial irradiator facilities, understand the requirements for safety assessments and emergency plans, be able to develop a radiation protection programme for irradiators, be familiar with the different types of industrial irradiators and their applications and understand the safety philosophy and design requirements for industrial irradiators. (author)

  18. Influence of natural antioxidants on lipid composition of beef burgers submitted to irradiation in 60 Co source and electron beams

    International Nuclear Information System (INIS)

    Trindade, Reginaldo Almeida da

    2007-01-01

    Radiation processing has been employed in some countries as a mean of treatment to assure microbiological safety of meat and meat products, avoiding the occurrence of food-borne disease. The ionizing radiation may cause some undesirable changes on chemistry composition of food and the lipid oxidation is one of the main reactions. In meat products processing industry, the lipid composition is directly related to nutritional and sensory quality of the product. For preventing oxidation, use of antioxidants which can be synthetic or natural, has been practically applied in some products. Currently, most attention has been given to natural antioxidants from herbs and spices like rosemary and oregano. The aim this study was to assess the antioxidant effects of either rosemary and oregano extract in beef burgers submitted to irradiation in 60 Co source with dose 6, 7 e 8 kGy, electron beams with dose 3,5 e 7 kGy and storage under freeze along 0, 45 e 90 days. The results showed that rosemary extract has the major antioxidant effects when it is used on heterogeneous food matrix like beef burger, but oregano extract was better efficient to delay lipid oxidation along storage time when it is used in synergism with rosemary and/or BHT/BHA. Although to have occurred changes in the fatty acids composition it was not possible to demonstrate a straight dependence of irradiation dose and/or storage time. Sensory analysis showed that between the samples prepared with natural antioxidants, the beef burger prepared with oregano has received better scores by panelists. Irradiated beef burger prepared with rosemary has received better scores when compared to non-irradiated one. The use of spices with antioxidant activity to avoid the oxidative damage in foods that contain fats in their formulation is thought to be promising to application in food facilities. (author)

  19. Effects of cryogenic irradiation on temperature sensors

    International Nuclear Information System (INIS)

    Courts, S.S.; Holmes, D.S.

    1996-01-01

    Several types of commercially available cryogenic temperature sensors were calibrated, irradiated at 4.2 K by a gamma or neutron source, and recalibrated in-situ to determine their suitability for thermometry in radiation environments. Comparisons were made between pre- and post-irradiation calibrations with the equivalent temperature shift calculated for each sensor at various temperature in the 4.2 K to 330 K range. Four post-irradiation calibrations were performed with annealing steps performed at 20 K, 80 K, and 330 K. Temperature sensors which were gamma irradiated were given a total dose of 10,000 Gy. Temperature sensors which were neutron irradiated were irradiated to a total fluence of 2 x 10 12 n/cm 2 . In general, for gamma radiation environments, diodes are unsuitable for use. Both carbon glass and germanium resistance sensors performed well at lower temperature, while platinum resistance sensors performed best above 30 K. Thin-film rhodium and Cernox trademark resistance sensors both performed well over the 4.2 K to 330 K range. Only thin-film rhodium and Cernox trademark resistance temperature sensors were neutron irradiated and they both performed well over the 4.2 K to 330 K range

  20. [Near infrared light irradiator using halogen lamp].

    Science.gov (United States)

    Ide, Yasuo

    2012-07-01

    The practical electric light bulb was invented by Thomas Alva Edison in 1879. Halogen lamp is the toughest and brightest electric light bulb. With light filter, it is used as a source of near infrared light. Super Lizer and Alphabeam are made as near infrared light irradiator using halogen lamp. The light emmited by Super Lizer is linear polarized near infrared light. The wave length is from 600 to 1,600 nm and strongest at about 1,000 nm. Concerning Super Lizer, there is evidence of analgesic effects and normalization of the sympathetic nervous system. Super Lizer has four types of probes. SG type is used for stellate ganglion irradiation. B type is used for narrow area irradiation. C and D types are for broad area irradiation. The output of Alphabeam is not polarized. The wave length is from 700 to 1,600 nm and the strongest length is about 1,000nm. Standard attachment is used for spot irradiation. Small attachment is used for stellate ganglion irradiation. Wide attachment is used for broad area irradiation. The effects of Alphabeam are thought to be similar to that of Super Lizer.

  1. Study of the biochemical indicators of chronic irradiation in rats.

    Science.gov (United States)

    Szabo, L D; Benko, A B; Gyenge, L; Predmerszky, T

    1976-01-01

    Daily urinary excretion of pseudouridine, creatinine and creatine of chronically irradiated Wistar rats was estimated. The irradiation conditions were: 60Co gamma source, dose-rate 10 rad/day, total dose 200, 400 and 600 rad. Control groups were kept under similar conditions. Urine samples were taken three times after the end of the irradiation period. It was found that: (1) pseudouridine excretion seems more suitable for indicating radiation injury than the creatine/creatinine ratio in chronic irradiation in rats; (ii) there are significant changes in dose dependence of pseudouridine excretion in the post-irradiation period; (iii) a new method for pseudouridine estimation gives closely similar data to those of earlier investigations.

  2. Regulatory aspects of food irradiation

    International Nuclear Information System (INIS)

    Nowlan, N.V.

    1985-01-01

    The role of the Nuclear Energy Board in relation to radiation safety in Ireland is described. The Board has the duty to control by licence all activities involving ionizing radiation, as well as providing advice and information to the Government on all aspects of radiation safety. The licensing procedures used by the Board, including site approval, construction, commissioning, source loading and commercial operation, in the licensing of large irradiation facilities were described, and an outline of the proposed new legislation which may become necessary if and when the irradiation of food for commercial purposes begins in Ireland is given

  3. Standardization of an irradiation field using 60Co and 137Cs sources (at Radioisotope Research Centre of Osaka University)

    International Nuclear Information System (INIS)

    Yamaguchi, Y.; Yamashito, J.; Yamamoto, T.; Yamamoto, J.; Nomura, T.

    1996-01-01

    On the occasion of installing the γ-ray irradiation system for animal experiments at the Radioisotope Research Center of Osaka University both lead collimators and shield screen have been supplemented to the system in order to satisfy the Japanese legal regulation that the dose equivalent rate outside the controlled area should be less than 300 μSv/w because the experimental room has not been so designed as to install such an apparatus. The original use of the system is to study the internal β-ray exposure of a small animal on a dosage of tritium water, which will be eliminated from a body with a biological half-life. Accordingly, the dose rate of internal exposure due to β-ray will change with time, and hence such a situation could be simulated with an external exposure due to γ-rays by changing the dose rate spatially, that is, the distance between the γ-ray source and a sample. It is, however, anticipated that improvement of the system would bring increase in the scattered γ-rays at an irradiation point and hence it becomes the purpose of the present paper to obtain precise exposures including scattered γ-rays at each irradiation point for animal experiments and also to find an optimum point for standard calibration where no scattered γ-rays are observed. For that purpose the effect of them will be evaluated with both calculations due to the Monte Carlo code for neutron photon transport (MCNP) and experiments due to the ionization chamber calibrated at the National Bureau of Standard in Japan. (author)

  4. Neutronics analysis of International Fusion Material Irradiation Facility (IFMIF). Japanese contributions

    International Nuclear Information System (INIS)

    Oyama, Yukio; Noda, Kenji; Kosako, Kazuaki.

    1997-10-01

    In fusion reactor development for demonstration reactor, i.e., DEMO, materials tolerable for D-T neutron irradiation are absolutely required for both mechanical and safety point of views. For this requirement, several kinds of low activation materials were proposed. However, experimental data by actual D-T fusion neutron irradiation have not existed so far because of lack of fusion neutron irradiation facility, except fundamental radiation damage studies at very low neutron fluence. Therefore such a facility has been strongly requested. According to agreement of need for such a facility among the international parties, a conceptual design activity (CDA) of International Fusion Material Irradiation Facility (IFMIF) has been carried out under the frame work of the IEA-Implementing Agreement. In the activity, a neutronics analysis on irradiation field optimization in the IFMIF test cell was performed in three parties, Japan, US and EU. As the Japanese contribution, the present paper describes a neutron source term as well as incident deuteron beam angle optimization of two beam geometry, beam shape (foot print) optimization, and dpa, gas production and heating estimation inside various material loading Module, including a sensitivity analysis of source term uncertainty to the estimated irradiation parameters. (author)

  5. Gamma irradiator dose mapping: a Monte Carlo simulation and experimental measurements

    International Nuclear Information System (INIS)

    Rodrigues, Rogerio R.; Ribeiro, Mariana A.; Grynberg, Suely E.; Ferreira, Andrea V.; Meira-Belo, Luiz Claudio; Sousa, Romulo V.; Sebastiao, Rita de C.O.

    2009-01-01

    Gamma irradiator facilities can be used in a wide range of applications such as biological and chemical researches, food treatment and sterilization of medical devices and products. Dose mapping must be performed in these equipment in order to establish plant operational parameters, as dose uniformity, source utilization efficiency and maximum and minimum dose positions. The isodoses curves are generally measured using dosimeters distributed throughout the device, and this procedure often consume a large amount of dosimeters, irradiation time and manpower. However, a detailed curve doses identification of the irradiation facility can be performed using Monte Carlo simulation, which reduces significantly the monitoring with dosimeters. The present work evaluates the absorbed dose in the CDTN/CNEN Gammacell Irradiation Facility, using the Monte Carlo N-particles (MCNP) code. The Gammacell 220, serial number 39, was produced by Atomic Energy of Canada Limited and was loaded with sources of 60 Co. Dose measurements using TLD and Fricke dosimeters were also performed to validate the calculations. The good agreement of the results shows that Monte Carlo simulations can be used as a predictive tool of irradiation planning for the CDTN/CNEN Gamma Cell Irradiator. (author)

  6. Effects of gamma irradiation of barley and malt on malting quality

    International Nuclear Information System (INIS)

    Köksel, H.; ÇElik, S.; ÖZkara, R.

    1998-01-01

    Two two-rowed barley cultivars, Tokak and Clerine, were irradiated at two different dose ranges (0.05–0.75 kGy and 0.5–5.0 kGy) using a 60Co source. Irradiation of barley at the medium levels before malting had detrimental effects on most of the malt quality criteria. The detrimental effects of irradiation was lower at doses up to 0.25 kGy. Irradiation of malt samples caused either slight or no deterioration of quality characteristics

  7. The efficacy testing of irradiated shrimp paste

    International Nuclear Information System (INIS)

    Nouchpramool, Kovit; Eamsiri, Jaruratana; Sujjabut, Surusak

    2005-10-01

    Two lots of shrimp paste from commercial source in Samutsakhon were irradiated at a recommended minimum dose of 6 kGy using a J S 8900 cobalt-60 carrier gamma irradiator of Thai Irradiation Center in Patum Thani. Red Perspex dosimeter were used to measure the absorbed dose throughout the product with emphasis on the region of minimum and maximum absorbed dose. This way, it was aimed to compare the dose effects of gamma irradiation on the microbiological, chemical and sensory quality of shrimp paste. The results indicated that the shrimp paste received minimum and maximum absorbed dose of 6.85 and 12.83 kGy with dose uniformity ratio of 1.87 . Throughput rate is 468 kilogram per hour. The microbiological load of shrimp paste was rather high resulting in not compliance with Thai industrial standard 1080-2535. Irradiation at 6.8 kGy reduced total viable bacterial count by one log cycle. Although the irradiated product was organoleptic ally acceptable and could be kept for 16 months at room temperature, mold and Clostridium perfringens were still present in some samples after irradiation and during prolonged storage in amount that exceeds the limitation of Thai industrial standard. Chemical properties such as p H, moisture and sodium chloride content of irradiated shrimp paste were not significantly changed after irradiation

  8. Late nonstochastic changes in pig skin after β irradiation

    International Nuclear Information System (INIS)

    Peel, D.M.; Hopewell, J.W.; Wells, J.; Charles, M.W.

    1985-01-01

    Late radiation-induced changes in pig skin have been assessed following irradiation with β-rays from a 22.5- or 15-mm-diameter 90 Sr/ 90 Y source and a 19- or 9-mm-diameter 170 Tm source. Late damage, in terms of dermal atrophy, was assessed 2 years after irradiation from measurements of dermal thickness of 40-50% of the control value, occurred at a dose of approx. 40 Gy from the 22.5-mm source and approx. 75 Gy from the 15-mm source. In the case of 170 Tm the 19- and 9-mm sources produced similar degrees of atrophy at equal doses. Maximum atrophy occurred at approx. 70 Gy, when the dermis was approx. 70% of the thickness of normal skin. Significant late tissue atrophy was seen at doses, from both types of radiation, which only produced minimal erythema in the early reaction. Such late reactions need to be taken into account when revised radiological protection criteria are proposed for skin

  9. Cobalt 60 gamma irradiation current status, trends and insights

    International Nuclear Information System (INIS)

    Corley, John T.

    1998-01-01

    This paper discusses the current status, trends and insights into the continued, safe use of cobalt 60 gamma irradiation. Also presented are some of the many initiatives undertaken at MDS Nordion. Topics covered include our investment for the future supply of raw materials and the latest news from source production. Briefly presented are the tasks associated with the safe transport of cobalt 60 around the world. Discussed is cobalt 60 usage at the customer site; more specifically maintaining source integrity, source utilization and irradiator design trends. Highlighted are industry trends for North America, Europe and the rest of the world. Finally presented are the challenges and opportunities for the industry. Stressed in the paper is the need to work together

  10. Irradiation preservation study on Beijing roast duck by low dose

    Energy Technology Data Exchange (ETDEWEB)

    Weiguo, Wang; Yongbao, Gu; Fengmei, Li [Beijing Normal Univ., BJ (China). Inst. of Low Energy Nuclear Physics; and others

    1989-02-01

    The irradiation technique combined with freezing has been used to control the microorganism in Beijing Roast Duck. Cobal-60 was chosen as {gamma}-ray source. The absorbed dose was 2 kGy on an average. After irrdiation, the microbe counts have reached the tolerable. Compared with untreated ducks, the irradiated ones showed no remarkable change in nutrition, chemistry, vitamin etc. It has been proved through test that the irradiated frozen Beijing Roast Duck is wholesome.

  11. Irradiation preservation study on Beijing roast duck by low dose

    International Nuclear Information System (INIS)

    Wang Weiguo; Gu Yongbao; Li Fengmei

    1989-01-01

    The irradiation technique combined with freezing has been used to control the microorganism in Beijing Roast Duck. Cobal-60 was chosen as γ-ray source. The absorbed dose was 2 kGy on an average. After irrdiation, the microbe counts have reached the tolerable. Compared with untreated ducks, the irradiated ones showed no remarkable change in nutrition, chemistry, vitamin etc. It has been proved through test that the irradiated frozen Beijing Roast Duck is wholesome

  12. Performance of irradiated CVD diamond micro-strip sensors

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D' Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Logiudice, A.; Lu, R.; Mac Lynne, L.; Manfredotti, C.; Meier, D. E-mail: dirk.meier@cern.ch; Mishina, M.; Moroni, L.; Noomen, J.; Oh, A.; Pan, L.S.; Pernicka, M.; Peitz, A.; Perera, L.; Pirollo, S.; Procario, M.; Riester, J.L.; Roe, S.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Walsh, A.M.; Wedenig, R.; Weilhammer, P.; Wetstein, M.; White, C.; Zeuner, W.; Zoeller, M.; Plano, R.; Somalwar, S.V.; Thomson, G.B

    2002-01-11

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article, we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a {beta}-source and the performance before and after intense (>10{sup 15}/cm{sup 2}) proton- and pion-irradiations. We find that low dose irradiation increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiation with protons 2.2x10{sup 15} p/cm{sup 2} lowers the signal-to-noise ratio slightly. Intense irradiation with pions 2.9x10{sup 15} {pi}/cm{sup 2} lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  13. Performance of irradiated CVD diamond micro-strip sensors

    CERN Document Server

    Adam, W; Bergonzo, P; Bertuccio, G; Bogani, F; Borchi, E; Brambilla, A; Bruzzi, Mara; Colledani, C; Conway, J; D'Angelo, P; Dabrowski, W; Delpierre, P A; Deneuville, A; Dulinski, W; van Eijk, B; Fallou, A; Fizzotti, F; Foulon, F; Friedl, M; Gan, K K; Gheeraert, E; Hallewell, G D; Han, S; Hartjes, F G; Hrubec, Josef; Husson, D; Kagan, H; Kania, D R; Kaplon, J; Kass, R; Koeth, T W; Krammer, Manfred; Lo Giudice, A; Lü, R; MacLynne, L; Manfredotti, C; Meier, D; Mishina, M; Moroni, L; Noomen, J; Oh, A; Pan, L S; Pernicka, Manfred; Peitz, A; Perera, L P; Pirollo, S; Procario, M; Riester, J L; Roe, S; Rousseau, L; Rudge, A; Russ, J; Sala, S; Sampietro, M; Schnetzer, S R; Sciortino, S; Stelzer, H; Stone, R; Suter, B; Tapper, R J; Tesarek, R J; Trischuk, W; Tromson, D; Vittone, E; Walsh, A M; Wedenig, R; Weilhammer, Peter; Wetstein, M; White, C; Zeuner, W; Zöller, M

    2002-01-01

    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a $\\beta$-source and the performance before and after intense ($>10^{15}/{\\rm cm^2}$) proton- and pion-irradiations. We find that low dose irradiations increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiations with protons ($2.2\\times 10^{15}~p/{\\rm cm^2}$) lowers the signal-to-noise ratio slightly. Intense irradiation with pions ($2.9\\times 10^{15}~\\pi/{\\rm cm^2}$) lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations.

  14. An advanced fusion neutron source facility

    International Nuclear Information System (INIS)

    Smith, D.L.

    1992-01-01

    Accelerator-based 14-MeV-neutron sources based on modifications of the original Fusion Materials Irradiation Facility are currently under consideration for investigating the effects of high-fluence high-energy neutron irradiation on fusion-reactor materials. One such concept for a D-Li neutron source is based on recent advances in accelerator technology associated with the Continuous Wave Deuterium Demonstrator accelerator under construction at Argonne National Laboratory, associated superconducting technology, and advances in liquid-metal technology. In this paper a summary of conceptual design aspects based on improvements in technologies is presented

  15. Decommissioning of the self-contained irradiator Gammacell 500

    International Nuclear Information System (INIS)

    Llanes Rodriguez, Marisleidys; Rodriguez Perdomo, Yanet; Fraga Acosta, Daniel; Soto Alvarez, Evelio; Soler Roger, Dulce Maria; Abreu Mendez, Yuliel; Benitez Navarro, Juan Carlos; Salgado Mojena, Mercedes; Perez Reyes, Yolanda

    2011-01-01

    The National Center for Animal and Plant Health used a Gammacell 500 irradiator, with twelve cobalt 60 sealed sources, for sterilization and decontamination of medical devices, pharmaceuticals and several raw materials. Due to the 25 years of exploitation time of the equipment, it was decided to close the facility. For dismantling the equipment, a methodology was developed taking into account the currently national regulations, the recommendations of the Atomic International Energy Organization, the consultation from the operation and equipment maintenance manual and the operational history. The design and implementation of the procedure for the irradiator dismantling are described. The Institutional Irradiator Decommissioning License was obtained, awarded by the National Center for Nuclear Safety. The dismantling operations involved in the container extraction with the radioactive sources and bulk forming to be transported. The operations were performed under radiological security conditions, keeping control under dose and superficial contamination rate during the process. As a conclusion, the notification for the release of the facility was received. (author)

  16. Preparation of {sup 114m}In low energy conversion electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Wrede, C., E-mail: wrede@uw.ed [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA 98195 (United States); Filippone, B.W. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Garcia, A.; Harper, G.C. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA 98195 (United States); Lassell, S. [Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States); Liu, J. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Department of Physics, Shanghai Jiao Tong University, Shanghai 200240 (China); Mendenhall, M.P. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Palmer, A.S.C. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA 98195 (United States); Pattie, R.W. [Department of Physics, North Carolina State University, Raleigh, North Carolina 27695 (United States); Will, D.I. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA 98195 (United States); Young, A.R. [Department of Physics, North Carolina State University, Raleigh, North Carolina 27695 (United States)

    2011-05-15

    Highlights: {yields} Controlled ion implantation of In-113 into thin Al substrate. {yields} Production of In-114m (half life = 50 days) by neutron irradiation. {yields} Use of In-114m as a source of electron lines and continuum for calibrations. {yields} Source reactivation by short neutron irradiation. -- Abstract: The preparation of {sup 114m}In sources of conversion electrons in the energy range 162-190 keV and {beta} continuum with a 1989 keV endpoint via ion implantation of {sup 113}In into Al substrates and subsequent irradiation by thermal and epi-thermal neutrons in a nuclear reactor is described.

  17. Isolation of radiation-resistant bacteria without exposure to irradiation

    International Nuclear Information System (INIS)

    Sanders, S.W.; Maxcy, R.B.

    1979-01-01

    Resistance to desiccation was utilized in the selection of highly radiation-resistant asporogenous bacteria from nonirradiated sources. A bacterial suspension in phosphate buffer was dried in a thin film at 25 0 C and 33% relative humidity. Storage under these conditions for 15 days or more reduced the number of radiation-sensitive bacteria. Further selection for radiation-resistant bacteria was obtained by irradiation of bacteria on velveteen in the replication process, therby avoiding the toxic effect of irradiated media. The similarity of radiation resistance and identifying characteristics in irradiated and non-irradiated isolates should allay some concerns that highly radiation-resistance bacteria have been permanently altered by radiation selection

  18. Brain anomalies induced by gamma irradiation in prenatal period

    International Nuclear Information System (INIS)

    Schmidt, S.L.

    1992-01-01

    Gamma irradiation has been utilized in order to produce cortical and callosal abnormalities. We have also checked for the presence of the aberrant longitudinal bundle in the brains of mice born acallosal due to prenatal irradiation is also checked. Pregnant mice were exposed to gamma irradiation from a 6 0 Co source at 16, 17 and 19 days of gestational age (E 16, E 17 and E 19) with total doses of 2 Gy and 3 Gy. At 60 days postnatal the offspring of irradiated animals were intra cardiac perfused, the brains were removed from the cranio and cut into coronal or para sagittal sections. (author)

  19. Economic Feasibility Study for Using Irradiation Technology in Preservation of Animalism Foods

    International Nuclear Information System (INIS)

    El Gameel, E.A.

    2011-01-01

    The present study discus the economic feasibility for the preservation animalism foods by using irradiation technology. This study has included the technical data, regression foretelling for the throughput, determination of irradiators types and radiation sources activity. This study comprises the financial analysis for the establishment animalism foods irradiation facilities (types: tote box, pallet conveyor) and the national return

  20. Hydrogen retention in ion irradiated steels

    International Nuclear Information System (INIS)

    Hunn, J.D.; Lewis, M.B.; Lee, E.H.

    1998-01-01

    In the future 1--5 MW Spallation Neutron Source, target radiation damage will be accompanied by high levels of hydrogen and helium transmutation products. The authors have recently carried out investigations using simultaneous Fe/He,H multiple-ion implantations into 316 LN stainless steel between 50 and 350 C to simulate the type of radiation damage expected in spallation neutron sources. Hydrogen and helium were injected at appropriate energy and rate, while displacement damage was introduced by nuclear stopping of 3.5 MeV Fe + , 1 microm below the surface. Nanoindentation measurements showed a cumulative increase in hardness as a result of hydrogen and helium injection over and above the hardness increase due to the displacement damage alone. TEM investigation indicated the presence of small bubbles of the injected gases in the irradiated area. In the current experiment, the retention of hydrogen in irradiated steel was studied in order to better understand its contribution to the observed hardening. To achieve this, the deuterium isotope ( 2 H) was injected in place of natural hydrogen ( 1 H) during the implantation. Trapped deuterium was then profiled, at room temperature, using the high cross-section nuclear resonance reaction with 3 He. Results showed a surprisingly high concentration of deuterium to be retained in the irradiated steel at low temperature, especially in the presence of helium. There is indication that hydrogen retention at spallation neutron source relevant target temperatures may reach as high as 10%

  1. Terminal load response law of coaxial cable to continuous wave electromagnetic irradiation

    International Nuclear Information System (INIS)

    Pan Xiaodong; Wei Guanghui; Li Xinfeng; Lu Xinfu

    2012-01-01

    In order to study the coupling response law of continuous wave electromagnetic irradiation to coaxial cable, the typical RF coaxial cable is selected as the object under test. The equipment or subsystem connected by coaxial cable is equivalent to a lumped load. Continuous wave irradiation effect experiments under different conditions are carried out to analyze the terminal load response law of coaxial cable. The results indicate that the coaxial cable has a frequency selecting characteristic under electromagnetic irradiation, and the terminal load response voltage peak appears at a series of discrete frequency points where the test cable's relative lengths equal to semi-integers. When the coaxial cable is irradiated by continuous wave, the induced sheath current converts to the differential-mode induced voltage between inner conductor and shielding layer through transfer impedance, and the internal resistance of induced voltage source is the characteristic impedance of the coaxial cable. The change in terminal load value has no influence on the response curve. The voltages on the terminal load and the internal resistance of equivalent induced voltage source obey the principle of voltage division. Moreover, when the sheath current on the coaxial cable is in resonance, the distributed induced voltage between adjacent current nodes is in the same polarity, which can be equivalent to a single induced voltage source. The induced voltage source which is adjacent to the terminal load plays the leading role in the irradiation response process. (authors)

  2. Evaluation of carotenoid contents in irradiated buriti (Mauritia flexuosa L.)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jaqueline M. da; Coelho, Maysa J.; Lima, Keila S.C.; Lima, Antonio L.S. [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Nuclear]. E-mail: maysa@ime.eb.br; Godoy, Ronoel L.O.; Pacheco, Sidney [EMBRAPA Agroindustria de Alimentos, Rio de Janeiro, RJ (Brazil)]. E-mail: ronoel@ctaa.embrapa.br; Ferreira, Rubemar S. [Centro Regional de Ciencias Nucleares do Centro-Oeste CRCN-CO/CNEN, Abadia de Goias, GO (Brazil); E-mail: rferreira@cnen.gov.br

    2007-07-01

    Buriti (Mauritia flexuosa L.), a typical Brazilian fruit, can be found at north, northeast and center-west regions in Brazil. It has a high nutritional value and is considered an excellent source of vitamin A precursors, called carotenoids, showing a majority of {beta}-carotene. It can be used in many regional dishes. In this study, Buriti in natura was treated with gamma irradiation, deriving from a cavity type research irradiator which has a Cs-137 radiation source, with the doses of 0.5 and 1.0 kGy. The objective is to evaluate the irradiation effects on nutritional quality maintenance and conservation of Buriti, focusing in optimizer the processing conditions and increase consumption as a way to fight vitamin A deficiency. Clinical, biological and dietetic studies have indicated that the lack of vitamin A is the main cause of night blindness and xerophthalmia. The use of food irradiation is growing and represents an economic benefit to the agriculture through the reduction of post harvesting losses. The irradiated fruits and the control group were evaluated through the total carotenoids analysis, by spectrophotometry, and the carotenoids (a and b-carotene and luteine) determined by High Performance Liquid Chromatography (HPLC). ANOVA was used to treat the results. The results show that buriti is an excellent source of total carotenoids, with a concentration of 44500 {mu}g/100 g in the pulp (70% of {beta}-carotene). The reduction of carotenoids contents due to the irradiation process does not compromise its nutritional quality that is still very above of recommendations, being the dose of 0.5 kGy more appropriate. (author)

  3. Evaluation of carotenoid contents in irradiated buriti (Mauritia flexuosa L.)

    International Nuclear Information System (INIS)

    Silva, Jaqueline M. da; Coelho, Maysa J.; Lima, Keila S.C.; Lima, Antonio L.S.; Ferreira, Rubemar S.

    2007-01-01

    Buriti (Mauritia flexuosa L.), a typical Brazilian fruit, can be found at north, northeast and center-west regions in Brazil. It has a high nutritional value and is considered an excellent source of vitamin A precursors, called carotenoids, showing a majority of β-carotene. It can be used in many regional dishes. In this study, Buriti in natura was treated with gamma irradiation, deriving from a cavity type research irradiator which has a Cs-137 radiation source, with the doses of 0.5 and 1.0 kGy. The objective is to evaluate the irradiation effects on nutritional quality maintenance and conservation of Buriti, focusing in optimizer the processing conditions and increase consumption as a way to fight vitamin A deficiency. Clinical, biological and dietetic studies have indicated that the lack of vitamin A is the main cause of night blindness and xerophthalmia. The use of food irradiation is growing and represents an economic benefit to the agriculture through the reduction of post harvesting losses. The irradiated fruits and the control group were evaluated through the total carotenoids analysis, by spectrophotometry, and the carotenoids (a and b-carotene and luteine) determined by High Performance Liquid Chromatography (HPLC). ANOVA was used to treat the results. The results show that buriti is an excellent source of total carotenoids, with a concentration of 44500 μg/100 g in the pulp (70% of β-carotene). The reduction of carotenoids contents due to the irradiation process does not compromise its nutritional quality that is still very above of recommendations, being the dose of 0.5 kGy more appropriate. (author)

  4. Measurement Of Lead Equivalent Thickness For Irradiation Room: An Analysis

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Azuhar Ripin; Husaini Salleh; Mohd Khairusalih Mohd Zin; Muhammad Jamal Muhd Isa; Mohd Faizal Abdul Rahman

    2014-01-01

    The Malaysian Ministry of Health (MOH) has established that the irradiation room must have a sufficient thickness of shielding to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for irradiation room at health clinics own by MOH. Results of measurement of 8 irradiation rooms conducted in 2014 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that almost all the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  5. Genetic study on heading time and plant height of wheat irradiated by 137Cs and 60Co γ-rays

    International Nuclear Information System (INIS)

    Wang Guixue; Zhu Xiaoda

    1995-01-01

    The 137 Cs and 60 Co γ-rays with 0, 20, 30 and 40 krad were used to irradiate two wheat varieties to study the genetic effects of both irradiation sources on heading time and plant height. It revealed that both irradiation sources had similar impact on heading time and plant height and the effects were significant. It was clear that both irradiation sources were able to induce the generation of early ripening and short-stalked mutants. With regard to the heading time and plant height, the means and genetic parameters, e.g., genetic variance, genetic coefficient of variation, heritability, genetic advance and relative genetic advance, varied with varieties, irradiation dosages and generations. Mutants with good characters were obtained by using variety 77-zhong-2882 and an irradiation dose of 30 krad. The genetic effects of irradiation were remarkable in their M 2 and M 3 generations

  6. Utilization of half-embryo test to identify irradiated beans

    International Nuclear Information System (INIS)

    Villavicencio, Anna Lucia C.H.; Mancini-Filho, Jorge

    1996-01-01

    Germination tests were carried out in irradiated and non-irradiated bean seeds which allow to observe characteristically variations on the shoots and roots. The methodology used in this work, is based upon biological changes which occur in two Brazilian beans, Phaseolus vulgaris L., var. carioca and Vigna unguiculata (L.) Walp, var. macacar, irradiated in a 60 Co source, with doses of 0,0.5, 1.0, 2.5, 5.0 and 10.0 kGy. The shoots and roots were observed during 3 days of culturing period under specified conditions. The differences observed in these two varieties were analysed immediately after irradiation and after 6 months of storage period at room temperature. Irradiated half-embryos showed markedly reduced root grow and almost totally retarded shoot elongation. Differences between irradiated and nonirradiated half-embryo could be observed after irradiation when different beans and storage time were varied. The shoots of half-embryos irradiated with more than 2.5 kGy did not undergo any elongation, whereas, the shoots of non-irradiated or those beans irradiated under 1.0 kGy elongated significantly within the 3 day test period. (author)

  7. TU-H-CAMPUS-TeP2-02: FLASH Irradiation Improves the Therapeutic Index Following GI Tract Irradiation

    International Nuclear Information System (INIS)

    Schueler, E; Trovati, S; King, G; Lartey, F; Rafat, M; Loo, B; Maxim, P

    2016-01-01

    Purpose: To investigate and characterize the radiobiological effectiveness of very high dose rate radiotherapy (FLASH) compared to conventional irradiation in an in vivo model. Methods: The gastrointestinal (GI) tract of C57BL/6 mice were irradiated with doses ranging between 10 and 18 Gy using a custom stereotactic jig. A Varian Clinac 21EX was modified to allow dose rates ranging from 0.05 to 240 Gy/s at the position of the mirror. With the gantry at 180 degrees, the jig holding the individual animals was placed above the mirror to take advantage of the reduced source to target distance. Mice were irradiated with 20MeV electrons. Following irradiation, the mice were monitored twice daily for morbidity and daily for weight changes. Results: Mice irradiated with FLASH irradiation had lower weight loss compared to the mice receiving conventional irradiation. Following FLASH irradiation, a maximum weight loss of ∼20% was observed at day 6 with subsequent recovery, while following conventional irradiation, higher weight losses was observed with fewer instances of recovery. Concerning survival, all mice in the conventionally irradiated groups had a 100% mortality in the range of 15.5–18 Gy, while the mice irradiated with FLASH irradiation had a 100% survival in the same range. Conclusion: These results have demonstrated proof of principle that FLASH irradiations have a dramatic impact on the overall survival of mice following GI tract irradiations. If the increase in the therapeutic window can be validated and understood, this would revolutionize the field of radiation oncology and lead to increased cure rates with reduced side effects following treatment, resulting in increased quality of life for cancer survivors. Funding: DoD, Award#:W81XWH-14-1-0014, Weston Havens Foundation, Bio-X (Stanford University), the Office of the Dean of the Medical School, the Office of the Provost (Stanford University), and the Swedish Childhood Cancer Foundation; BL and PM are

  8. TU-H-CAMPUS-TeP2-02: FLASH Irradiation Improves the Therapeutic Index Following GI Tract Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, E; Trovati, S; King, G; Lartey, F; Rafat, M; Loo, B; Maxim, P [Stanford University School of Medicine, Palo Alto, California (United States)

    2016-06-15

    Purpose: To investigate and characterize the radiobiological effectiveness of very high dose rate radiotherapy (FLASH) compared to conventional irradiation in an in vivo model. Methods: The gastrointestinal (GI) tract of C57BL/6 mice were irradiated with doses ranging between 10 and 18 Gy using a custom stereotactic jig. A Varian Clinac 21EX was modified to allow dose rates ranging from 0.05 to 240 Gy/s at the position of the mirror. With the gantry at 180 degrees, the jig holding the individual animals was placed above the mirror to take advantage of the reduced source to target distance. Mice were irradiated with 20MeV electrons. Following irradiation, the mice were monitored twice daily for morbidity and daily for weight changes. Results: Mice irradiated with FLASH irradiation had lower weight loss compared to the mice receiving conventional irradiation. Following FLASH irradiation, a maximum weight loss of ∼20% was observed at day 6 with subsequent recovery, while following conventional irradiation, higher weight losses was observed with fewer instances of recovery. Concerning survival, all mice in the conventionally irradiated groups had a 100% mortality in the range of 15.5–18 Gy, while the mice irradiated with FLASH irradiation had a 100% survival in the same range. Conclusion: These results have demonstrated proof of principle that FLASH irradiations have a dramatic impact on the overall survival of mice following GI tract irradiations. If the increase in the therapeutic window can be validated and understood, this would revolutionize the field of radiation oncology and lead to increased cure rates with reduced side effects following treatment, resulting in increased quality of life for cancer survivors. Funding: DoD, Award#:W81XWH-14-1-0014, Weston Havens Foundation, Bio-X (Stanford University), the Office of the Dean of the Medical School, the Office of the Provost (Stanford University), and the Swedish Childhood Cancer Foundation; BL and PM are

  9. Influence of the irradiation by the {gamma} rays on various factors of immunity; Influence de l'irradiation par les rayons {gamma} sur divers facteurs d'immunite

    Energy Technology Data Exchange (ETDEWEB)

    Gaude, G; Coursaget, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    Exposed animals often present, in the days or weeks following the irradiation, heavy infectious lesions. The goal of this survey was to search the influence of the total irradiation by the gamma radiation from cobalt-60, on the organism, on the phagocytic power of the leukocytes and on the biogenesis of antibodies. The experiences were done on hundred animals, rabbits and guinea pigs. All irradiations have been achieved with eight sources of Cobalt 60 of 10 curies each, disposed on a sphere of 1 m, the animal living the region neighboring of the center. The intensity of the radiation, in these conditions, is about 100 roentgens per hour. (authors) [French] Les animaux irradies presentent souvent, dans les jours ou les semaines qui suivent l'irradiation, de graves lesions infectieuses. Le but de cette etude etait de rechercher l'influence de l'irradiation totale de l'organisme par le rayonnement gamma du cobalt 60 sur le pouvoir phagocytaire des leucocytes et sur la biogenese des anticorps. Les experiences portent sur une centaine d'animaux, lapins et cobayes. Toutes les irradiations ont ete realisees avec huit sources de Cobalt 60 de 10 curies chacune, disposees sur une sphere de 1 m de rayon, les animaux ocoupant la region voisine du centre. L'intensite du rayonnement est, dans ces conditions, d'environ 100 roentgens par heure. (auteurs)

  10. Conceptual design of gamma irradiator (ISG-500) for preservation of farming product

    International Nuclear Information System (INIS)

    S Budihardjo; Dian F Atmoko; Syamsurijjal Ramja; Sutomo; A Suntoro; Pudjijanto MS; Nada Mamada

    2010-01-01

    A conceptual design of gamma irradiator ISG-500 for a preservation of farming product has been done. The design of gamma irradiator are multi purpose with the activity of radiation source used at 2x250 kCi cobalt-60. This gamma irradiator will be built by using local materials, like as for the building structure construction, the mechanical and electrical systems and for the instrumentation and control systems. The sources of radiation that will be used is Co60 pencil types (C 188 - Nordion), concrete structured building according to BAPETEN rule and the numbers of carriers that will be used are 15 carriers. (author)

  11. Development of radiation fusion technology with food technology by the application of high dose irradiation

    International Nuclear Information System (INIS)

    Lee, Juwoon; Kim, Jaehun; Choi, Jongil

    2012-04-01

    This study was performed to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering was developed. Irradiation condition to destroy radiation resistant foodborne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources was developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not was developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin was developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam was introduced. Results from this research project, the followings are expected. Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of foodborne outbreaks. Build of SPS/TBT system against imported products and acceleration of domestic product export. Systemized

  12. Development of Radiation Fusion Technology with Food Technology by the Application of High Dose Irradiation

    International Nuclear Information System (INIS)

    Kim, Ju Won; Kim, Jae Hun; Choi, Jong Il

    2010-04-01

    This study was studied to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering were developed. Irradiation condition to destroy radiation resistant food borne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources were developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not were developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin were developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam were introduced. Results from this research project, the followings are expected. (1) Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. (2) Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of food borne outbreaks. (3) Build of SPS/TBT system against imported products and acceleration of domestic product export

  13. Development of Radiation Fusion Technology with Food Technology by the Application of High Dose Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Won; Kim, Jae Hun; Choi, Jong Il

    2010-04-15

    This study was studied to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering were developed. Irradiation condition to destroy radiation resistant food borne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources were developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not were developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin were developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam were introduced. Results from this research project, the followings are expected. (1) Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. (2) Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of food borne outbreaks. (3) Build of SPS/TBT system against imported products and acceleration of domestic product export

  14. Development of radiation fusion technology with food technology by the application of high dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juwoon; Kim, Jaehun; Choi, Jongil; and others

    2012-04-15

    This study was performed to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering was developed. Irradiation condition to destroy radiation resistant foodborne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources was developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not was developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin was developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam was introduced. Results from this research project, the followings are expected. Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of foodborne outbreaks. Build of SPS/TBT system against imported products and acceleration of domestic product export. Systemized

  15. Chemical and microbial quality of irradiated ground ginger

    International Nuclear Information System (INIS)

    Andrews, L.S.

    1995-01-01

    Fresh ground ginger was irradiated with a 10-kGy ionizing radiation dose from a Cobalt-60 source. Gamma radiation decreased most of the extractable volatile flavor components. Those known to contribute to typical ginger flavor, e.g., zingiberene, beta-sesquiphellandrene, beta-bisabolene, farnesene isomers, arcurcumene, and alpha-cubebene, decreased 27-59% following irradiation. Most odors recognized through gas chromatography/olfactometry produced similar patterns from irradiated and nonirradiated samples. The radiation treatment reduced the aerobic microbial population from 10(8) to 10(1) CFU/g. Sensory qualities of flavor, color and odor of ginger powder were similar for treated and untreated ginger

  16. Degradation of SiGe devices by proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohyama, Hidenori; Hayama, Kiyoteru [Kumamoto National Coll. of Technology, Nishigoshi (Japan); Vanhellemont, J; Takami, Yasukiyo; Sunaga, Hiromi; Nashiyama, Isamu; Uwatoko, Yoshiya; Poortmans, J; Caymax, M

    1997-03-01

    The degradation and recovery behavior of strained Si{sub 1-x}Ge{sub x} diodes and heterojunction bipolar transistors (HBTs) by irradiated by protons are studied. The degradation of device performance and the generation of lattice defects are reported as a function of fluence and germanium content and also compared extensively with previous results obtained on electron and neutron irradiated devices. In order to study the recovery behavior of the irradiated devices, isochronal annealing is performed. The radiation source dependence of the degradation is discussed taking into account the number of knock-on atoms and the nonionizing energy loss (NIEL). (author)

  17. Short-term solar irradiation forecasting based on Dynamic Harmonic Regression

    International Nuclear Information System (INIS)

    Trapero, Juan R.; Kourentzes, Nikolaos; Martin, A.

    2015-01-01

    Solar power generation is a crucial research area for countries that have high dependency on fossil energy sources and is gaining prominence with the current shift to renewable sources of energy. In order to integrate the electricity generated by solar energy into the grid, solar irradiation must be reasonably well forecasted, where deviations of the forecasted value from the actual measured value involve significant costs. The present paper proposes a univariate Dynamic Harmonic Regression model set up in a State Space framework for short-term (1–24 h) solar irradiation forecasting. Time series hourly aggregated as the Global Horizontal Irradiation and the Direct Normal Irradiation will be used to illustrate the proposed approach. This method provides a fast automatic identification and estimation procedure based on the frequency domain. Furthermore, the recursive algorithms applied offer adaptive predictions. The good forecasting performance is illustrated with solar irradiance measurements collected from ground-based weather stations located in Spain. The results show that the Dynamic Harmonic Regression achieves the lowest relative Root Mean Squared Error; about 30% and 47% for the Global and Direct irradiation components, respectively, for a forecast horizon of 24 h ahead. - Highlights: • Solar irradiation forecasts at short-term are required to operate solar power plants. • This paper assesses the Dynamic Harmonic Regression to forecast solar irradiation. • Models are evaluated using hourly GHI and DNI data collected in Spain. • The results show that forecasting accuracy is improved by using the model proposed

  18. Considerations in the public acceptance of sewage sludge irradiation systems

    International Nuclear Information System (INIS)

    Dix, G.P.

    1975-01-01

    Considerations associated with public acceptance of municipal sewage sludge irradiation systems are discussed including the benefit to society, public information and safeguards. Public acceptance of products is based upon the benefit to society as measured by reduced consumer costs, minimization of public risk and enhancement of the quality of life and the environment. When viewed in this positive light, the sludge irradiator has high potential benefits to the community. If large-scale engineering experiments show that sludge irradiation is more cost-effective than other methods, reduced consumer costs would result. Today many sewage plants do not consistently remove pathogens from sludge; sludge irradiation could be an effective method of pathogen removal and result in avoidance of a major public risk. The sludge irradiator may be able to clean up recreational areas, reduce noxious odours from sewage treatment facilities, and reduce the energy requirements for producing fertilizer and soil conditioners and conserve their mineral content. Plant safeguards must be explained to dispel public concern that the contents of the source can be released to the sludge accidentally. This will be the main issue within the technical sector of the public, and the design, procedural and administrative safeguards of the plant must be fully explained. The primary risk associated with sludge irradiators will be the remote possibility of source leakage into the sludge. The various safeguards in sludge irradiation plants are discussed in detail including the form of the radionuclide, encapsulation, the irradiation chamber, safeguards instrumentation, shielding and thermal safeguards. (Author)

  19. UY 114 Standard: Panoramics irradiation industrial plants design, class IV, with radioactive source under water deposited: approved by the resolution of the Ministry of Industry, Energy and Mining of 22/5/03

    International Nuclear Information System (INIS)

    2003-01-01

    This standard is emploi fix irradiation plants design, panoramics class IV with radioactive source under water, uruguaian Regulation Authoritie establish general requirements and practices relating with the radiological safety

  20. Beneficial Uses Program. Progress report, period ending December 31, 1977. [Irradiated sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    1978-11-01

    The Beneficial Uses Program is a comprehensive program to develop the necessary technologies for cost-beneficial uses of existing and future surplus radioactive materials. The major portion of the work at Sandia is concentrated in two sub-programs: the Waste Resources Utilization Program and the Separation Technology and Source Development Program. Progress is reported on: (1) the Sandia Irradiator for Dried Sewage Solids; (2) bacteriology; (3) mycology; (4) virology; (5) animal feeds containing irradiated sewage solids; (6) use of irradiated sewage sludge as fertilizer; and (7) development of /sup 90/Sr and /sup 137/Cs radiation sources obtained from radioactive wastes. (TFD)

  1. Beneficial Uses Program. Progress report, period ending March 31, 1979. [Irradiated sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    1979-08-01

    The Beneficial Uses Program is a comprehensive program to develop the necessary technologies for cost-beneficial uses of existing and future surplus radioactive materials. The major portion of the work at Sandia is concentrated in two sub-programs: the Waste Resources Utilization Program and the Separation Technology and Source Development Program. Progress is reported on: (1) the Sandia Irradiator for Dried Sewage Solids; (2) bacteriology; (3) mycology; (4) virology; (5) animal feeds containing irradiated sewage solids; (6) use of irradiated sewage sludge as fertilizer; and (7) development of /sup 137/Cs radiation sources obtained from radioactive wastes. (TFD)

  2. Methods of computer experiment in gamma-radiation technologies using new radiation sources

    CERN Document Server

    Bratchenko, M I; Rozhkov, V V

    2001-01-01

    Presented id the methodology of computer modeling application for physical substantiation of new irradiation technologies and irradiators design work flow. Modeling tasks for irradiation technologies are structured along with computerized methods of their solution and appropriate types of software. Comparative analysis of available packages for Monte-Carlo modeling of electromagnetic processes in media is done concerning their application to irradiation technologies problems. The results of codes approbation and preliminary data on gamma-radiation absorbed dose distributions for nuclides of conventional sources and prospective Europium-based gamma-sources are presented.

  3. Apparatus for electron beam irradiation of objects

    International Nuclear Information System (INIS)

    Dmitriev, S.P.; Ivanov, A.S.; Sviniin, M.P.; Fedotov, M.T.

    1984-01-01

    This patent provides an apparatus for electron beam irradiation of objects, comprising a shaper of a ribbon-shaped electron beam and a deflecting electromagnet having a frame-type magnetic circuit and used to direct said electron beam onto an irradiated object substantially at an angle of 90 degrees. The deflecting electromagnet has two poles extended over the width of the irradiated object and comprises two windings embracing said poles and connected to a d.c. source. The deflecting electromagnet is arranged in such a manner that the trajectories of the electrons at an area from the shaper to the electromagnet are inclined to the plane of the frame of its magnetic circuit

  4. The Techniques Of Food Irradiation

    International Nuclear Information System (INIS)

    Olorunda, A.O. Department Of Food Technology, University Of Ibadan, Nigeria.

    1996-01-01

    Food irradiation is a technique which is increasingly being recognised as an effective method for reducing post-harvest food losses, ensuring hygienic quality of food and facilitating wider trade of certain food items. Irradiation of food may be used to achieve a variety of desirable objectives including the following which are classified according to the average radiation dose requirement: i. Low dose application (up to about 1 kg), for inhibition of sprouting in yams, potatoes, onions, etc. insect disinfestation and delay of ripening in fruits. ii. Medium dose applications (about 1-10kgy), for reduction of micro-organisms and improvement in technological properties of food. iii. High dose application (about 10-50kgy) which is used for sterilization for commercial purposes and elimination of viruses. From the point of view of food safety the energy level of the radiation applied to food is the most important characteristics that has to be regulated in order to prevent the possible formation of induced radio activity. Fortunately, the most commonly used isotopic sources 60Co and 137Cs; and machine sources such as the electron beam generators, induced radio activity is negligible, short lived and lower than that causing radio activity. This and other scientific and technical aspects of the commercial application irradiation technology with respect Nigeria have been examined in this paper along side with those of its politics and social policy

  5. Modelled basic parameters for semi-industrial irradiation plant design

    International Nuclear Information System (INIS)

    Mangussi, J.

    2009-01-01

    The basic parameters of an irradiation plant design are the total activity, the product uniformity ratio and the efficiency process. The target density, the minimum dose required and the throughput depends on the use to which the irradiator will be put at. In this work, a model for calculating the specific dose rate at several depths in an infinite homogeneous medium produced by a slab source irradiator is presented. The product minimum dose rate for a set of target thickness is obtained. The design method steps are detailed and an illustrative example is presented. (author)

  6. Some features of irradiated chitosan and its biological effect

    International Nuclear Information System (INIS)

    Hai, Le; Hien, Nguyen Quoc; Luan, Le Quang; Hanh, Truong Thi; Man, Nguyen Tan; Ha, Pham Thi Le; Thuy, Tran Thi; Yoshii, Fumio; Kume, Tamikazu

    2001-01-01

    Preparation of chitosan oligomer by radiation degradation was carried out on the gamma Co-60 source. The radiation degradation yield (G d ) of the chitosan was found to be of 1.03. The oligochitosan with 50% of dp>8 fraction was obtained by irradiating the 10% (w/v) chitosan solution in 5% acetic acid at 45 kGy for the chitosan having the initial viscometric average molecular weight, Mv=60,000. Irradiated chitosan showed higher antifungal effect than that of unirradiated one. Furthermore, the irradiated chitosan also showed the growth-promotion effect for plants. (author)

  7. C-188 cobalt-60 sealed source integrity: source monitoring

    International Nuclear Information System (INIS)

    Defalco, G.M.; Shah, V.

    1995-01-01

    The integrity of C-188 cobalt-60 sealed sources used for radiation processing will be a key factor in the continued industrial acceptance and growth of gamma irradiation technology. Given the public's relatively poor understanding of most nuclear topics and the news media's tendency to sensationalize events, it is appropriate for suppliers and users of gamma technology to be vigilant and conservative regarding the application of cobalt-60 sources to industrial purposes. Nordion's recent decision to extend the optional warranty on its C-188 cobalt-60 sealed source from 15 years to 20 years is based on over 30 years of data generated from its on-going SOURCE SURVEILLANCE PROGRAM. This paper presents an overview of the C-188 SOURCE SURVEILLANCE PROGRAM. (author)

  8. Gamma irradiation stability studies of coir pith - a lignocellulosic biosorbent for strontium

    International Nuclear Information System (INIS)

    Parab, Harshala; Remya Devi, P.S.; Shenoy, Niyoti; Kumar, Sangita D.; Reddy, A.V.R.

    2015-01-01

    The effects of gamma irradiation on a lignocellulosic biosorbent-coir pith was investigated. The biosorbent was irradiated up to a dosage of 3.6 MGy using high intensity 60 Co source. The physicochemical changes in the coir pith after exposure to γ radiation were evaluated using FTIR and TG-DTA measurements. Coir pith, when irradiated in air showed structural similarity with that of non irradiated coir. However irradiation in aqueous medium partially altered the chemical linkages in coir pith. Thermal analysis revealed stepwise decomposition of structural constituents of coir pith. The changes in the strontium sorption properties of the coir pith upon γ-irradiation were examined. (author)

  9. Experience in Cuba in the licensing during import, commissioning and operation of an Irradiator LLCo ISOGAMMA

    International Nuclear Information System (INIS)

    Forteza, Yamil Lopez; Reyes, Yolanda Perez; Garcia, Jose R. Quevedo; Molina, Igor I. Sarabia; Gonzalez, Leonel Omarovich; Zubiaur, Omar Cruz

    2013-01-01

    This work presented the experiences during the process of licensing an irradiator ISOGAMMA LLCo model according to the recommendations of the International Atomic Energy (IAEA). Aspects of the safety assessment are detailed, as well as control and verification requirements for radiation safety and security at different stages of the process (import, transportation, installation irradiator loading 60Co sources, commissioning and operation) of irradiator recently installed in Cuba. The results of the evaluation carried a source of reference and consultation necessary for the work of the regulator to consider for similar processes that lie ahead in other facilities irradiation

  10. Neutron source for a reactor

    International Nuclear Information System (INIS)

    Kobayashi, Hiromasa.

    1975-01-01

    Object: To easily increase a start-up power of a reactor without irradiation in other reactors. Structure: A neutron source comprises Cf 252 , a natural antimony rod, a layer of beryllium, and a vessel of neutron source. On upper and lower portion of Cf 252 are arranged natural antimony rods, which are surrounded by the Be layer, the entirety being charged into the vessel. The Cf 252 may emit neutron, has a half life more than a period of operating cycle of the reactor and is less deteriorated even irradiated by radioactive rays while being left within the reactor. The natural antimony rod is radioactivated by neutron from Cf 252 and neutron as reactor power increases to emit γ rays. The Be absorbs γ rays to emit the neutron. The antimony rod is irradiated within the reactor. Further, since the Cf 252 is small in neutron absorption cross section, it is hard to be deteriorated even while being inserted within the reactor. (Kamimura, M.)

  11. Thymus repair compared with hemopoiesis repair in spleen after protracted irradiation

    International Nuclear Information System (INIS)

    Mackova, N.

    1987-01-01

    Matured female mice of ICR strain were irradiated from a 60 Co source with a daily dose rate of 5 Gy till total accumulated dose of 10 Gy for 2 days. Animals were examined in various intervals within 42 days after irradiation. The results revealed that protracted irradiation will induce a massive injury to hemopoiesis. The first repair processes occurred in thymus and were characterized by two phases. The first repair wave peaked about the day 10 and the second about the day 30 after irradiation. The repair processes observed in the red pulp of the spleen reached their highest intensity approximately between the days 14-16 after irradiation. (author)

  12. Developing a training programme for radiation protection officers at industrial irradiators

    International Nuclear Information System (INIS)

    Davor, P.

    2013-04-01

    A training programme for staff of irradiation facilities especially radiation safety officers at industrial irradiation facilities has been developed. The programme focused on technical and administrative basis for ensuring radiation safety at the practices. It consists of thirteen modules ranging from fundamentals of radiation, biological effects of ionizing radiation as well as the technical and administrative issues pertinent to radiation safety of the sources. The overall objective of this programme was to build competence in the area of radiation protection and raise the confidence level of staff of industrial irradiation facilities. The modules are structured in a manner that attempts to give a good understanding to participants on safety features of irradiators and use of radiation monitoring equipment. Each module has specific objectives and expected outcome and the course content is also stated under each module. The duration of the whole programme is sixteen weeks and the participants are expected to have some working knowledge in radiation protection and safe use of radiation sources. (au)

  13. An integrated on-line irradiation and in situ live cell imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Ying; Fu, Qibin; Wang, Weikang; Liu, Yu; Liu, Feng; Yang, Gen, E-mail: gen.yang@pku.edu.cn; Wang, Yugang

    2015-09-01

    Ionizing radiation poses a threat to genome integrity by introducing DNA damages, particularly DNA double-strand breaks (DSB) in cells. Understanding how cells react to DSB and maintain genome integrity is of major importance, since increasing evidences indicate the links of DSB with genome instability and cancer predispositions. However, tracking the dynamics of DNA damages and repair response to ionizing radiation in individual cell is difficult. Here we describe the development of an on-line irradiation and in situ live cell imaging system based on isotopic sources at Institute of Heavy Ion Physics, Peking University. The system was designed to irradiate cells and in situ observe the cellular responses to ionizing radiation in real time. On-line irradiation was achieved by mounting a metal framework that hold an isotopic γ source above the cell culture dish for γ irradiation; or by integrating an isotopic α source to an objective lens under the specialized cell culture dish for α irradiation. Live cell imaging was performed on a confocal microscope with an environmental chamber installed on the microscope stage. Culture conditions in the environment chamber such as CO{sub 2}, O{sub 2} concentration as well as temperature are adjustable, which further extends the capacity of the system and allows more flexible experimental design. We demonstrate the use of this system by tracking the DSB foci formation and disappearance in individual cells after exposure to irradiation. On-line irradiation together with in situ live cell imaging in adjustable culture conditions, the system overall provides a powerful tool for investigation of cellular and subcellular response to ionizing radiation under different physiological conditions such as hyperthermia or hypoxia.

  14. An integrated on-line irradiation and in situ live cell imaging system

    International Nuclear Information System (INIS)

    Liang, Ying; Fu, Qibin; Wang, Weikang; Liu, Yu; Liu, Feng; Yang, Gen; Wang, Yugang

    2015-01-01

    Ionizing radiation poses a threat to genome integrity by introducing DNA damages, particularly DNA double-strand breaks (DSB) in cells. Understanding how cells react to DSB and maintain genome integrity is of major importance, since increasing evidences indicate the links of DSB with genome instability and cancer predispositions. However, tracking the dynamics of DNA damages and repair response to ionizing radiation in individual cell is difficult. Here we describe the development of an on-line irradiation and in situ live cell imaging system based on isotopic sources at Institute of Heavy Ion Physics, Peking University. The system was designed to irradiate cells and in situ observe the cellular responses to ionizing radiation in real time. On-line irradiation was achieved by mounting a metal framework that hold an isotopic γ source above the cell culture dish for γ irradiation; or by integrating an isotopic α source to an objective lens under the specialized cell culture dish for α irradiation. Live cell imaging was performed on a confocal microscope with an environmental chamber installed on the microscope stage. Culture conditions in the environment chamber such as CO 2 , O 2 concentration as well as temperature are adjustable, which further extends the capacity of the system and allows more flexible experimental design. We demonstrate the use of this system by tracking the DSB foci formation and disappearance in individual cells after exposure to irradiation. On-line irradiation together with in situ live cell imaging in adjustable culture conditions, the system overall provides a powerful tool for investigation of cellular and subcellular response to ionizing radiation under different physiological conditions such as hyperthermia or hypoxia

  15. An integrated on-line irradiation and in situ live cell imaging system

    Science.gov (United States)

    Liang, Ying; Fu, Qibin; Wang, Weikang; Liu, Yu; Liu, Feng; Yang, Gen; Wang, Yugang

    2015-09-01

    Ionizing radiation poses a threat to genome integrity by introducing DNA damages, particularly DNA double-strand breaks (DSB) in cells. Understanding how cells react to DSB and maintain genome integrity is of major importance, since increasing evidences indicate the links of DSB with genome instability and cancer predispositions. However, tracking the dynamics of DNA damages and repair response to ionizing radiation in individual cell is difficult. Here we describe the development of an on-line irradiation and in situ live cell imaging system based on isotopic sources at Institute of Heavy Ion Physics, Peking University. The system was designed to irradiate cells and in situ observe the cellular responses to ionizing radiation in real time. On-line irradiation was achieved by mounting a metal framework that hold an isotopic γ source above the cell culture dish for γ irradiation; or by integrating an isotopic α source to an objective lens under the specialized cell culture dish for α irradiation. Live cell imaging was performed on a confocal microscope with an environmental chamber installed on the microscope stage. Culture conditions in the environment chamber such as CO2, O2 concentration as well as temperature are adjustable, which further extends the capacity of the system and allows more flexible experimental design. We demonstrate the use of this system by tracking the DSB foci formation and disappearance in individual cells after exposure to irradiation. On-line irradiation together with in situ live cell imaging in adjustable culture conditions, the system overall provides a powerful tool for investigation of cellular and subcellular response to ionizing radiation under different physiological conditions such as hyperthermia or hypoxia.

  16. Development of system for product tracking and data acquisition of data irradiation process in large gamma irradiators

    International Nuclear Information System (INIS)

    Soares, Jose Roberto

    2010-01-01

    The sterilization of medical care products using ionizing radiation is a consolidated technique. In Brazil there are in operation gamma irradiators with capacity between 0.37 PBq (10kCi) 185 PBq (5 MCi) using radioisotopes 60 Co as radiation source. The developed work provides an accurate control and a data acquisition for the application of Good Manufacturing Practices during all phases of an irradiation process, required by the standards of ANVISA, ISO and IAEA technical recommendations for the treatment of foods and medical products. All the steps involved in the irradiation treatment are mapped into process flow (work flow), where each agent (participant) has its systematized tasks. The data acquisition process, monitoring and control, are based on a set of tools (free software licenses) integrated by a network of efficient communication, including the use of Web resources. Using the Gamma Irradiator Multipurpose IPEN/CNEN/USP all the development was performed to be applied in irradiators facilities operating in industrial scale. The system enables a complete traceability of the process, in real time, for any participant and also the storage of the corresponding records to be audited. (author)

  17. Development of system for product tracking and data acquisition of data irradiation process in large gamma irradiators

    International Nuclear Information System (INIS)

    Soares, Jose R.; Rela, Paulo R.; Costa, Fabio E.

    2011-01-01

    The sterilization of medical care products using ionizing radiation is a consolidated technique. In Brazil there are in operation gamma irradiators with capacity between 0.37 PBq (10kCi) 185 PBq (5 MCi) using radioisotopes 60 Co as radiation source. The developed work provides an accurate control and data acquisition for the application of good manufacturing practices during all phases of an irradiation process, required by the standards of ANVISA, technical ISO and IAEA recommendations for the treatment of foods and medical products. All the steps involved in the irradiation treatment are mapped into process flow (work flow), where each agent (participant) has its systematized tasks. The automatic data process acquisition using wireless ZigBee technology, monitoring and control, are based on a set of tools (free software licenses) integrated by a network of efficient communication, including the use of Web resources. Using the Gamma Irradiator Multipurpose IPEN/CNEN-SP all the development was performed to be applied in irradiators' facilities operating in industrial scale. The system enables a complete traceability of the process, in real time, for any participant and also the storage of the corresponding records to be audited. (author)

  18. Development of system for product tracking and data acquisition of data irradiation process in large gamma irradiators

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Jose R., E-mail: joseroberto.soares@mackenzie.br [Universidade Presbiteriana Mackenzie. Escola de Engenharia. Sao Paulo, SP (Brazil); Rela, Paulo R.; Costa, Fabio E., E-mail: prela@ipen.br, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The sterilization of medical care products using ionizing radiation is a consolidated technique. In Brazil there are in operation gamma irradiators with capacity between 0.37 PBq (10kCi) 185 PBq (5 MCi) using radioisotopes {sup 60}Co as radiation source. The developed work provides an accurate control and data acquisition for the application of good manufacturing practices during all phases of an irradiation process, required by the standards of ANVISA, technical ISO and IAEA recommendations for the treatment of foods and medical products. All the steps involved in the irradiation treatment are mapped into process flow (work flow), where each agent (participant) has its systematized tasks. The automatic data process acquisition using wireless ZigBee technology, monitoring and control, are based on a set of tools (free software licenses) integrated by a network of efficient communication, including the use of Web resources. Using the Gamma Irradiator Multipurpose IPEN/CNEN-SP all the development was performed to be applied in irradiators' facilities operating in industrial scale. The system enables a complete traceability of the process, in real time, for any participant and also the storage of the corresponding records to be audited. (author)

  19. Experience with a pilot plant for the irradiation of sewage sludge; bacteriological and parasitological studies after irradiation

    International Nuclear Information System (INIS)

    Wizigmann, I.

    1976-01-01

    Reduction of viable micro-organisms could be achieved by irradiation of sewage sludge in a pilot plant ( 60 Co gamma-radiation 300 krad, 300 min.). The reduction amounted to an average of 2 log with Enterococces and total bacterial count and to 5 log with Enterobacteriaceae. Out of 23 sludge batches from digestor II, 21 were free of Salmonella after irradiation. Of 7 sludge batches from digester I with higher level of Enterobacteriaceae and Salmonellae 5 batches still contained Salmonella after treatment. By making some alterations in the pipe system and reloading futher Cobalt 60-sources the duration of irradiation could be reduced to 65 min. while maintaining the dose level of 300 krad. Employing this altered procedure 16 batches from digestor II and 4 from digestor I were irradiated to date. Only in one of 60 samples was Salmonella detectable. The hygenic effects of the irradiation unit were confirmed by means of a model experiment with bacterial pure cultures. Microorganisms of different species as well as strains of the same species differ in their radiation-sensitivity. Parasitological experiments were conducted with Ascaris suum ova. No embryonation was noted after radiation treatment at a dose of 300 krad. (author)

  20. Training manual on food irradiation technology and techniques. 2. ed.

    International Nuclear Information System (INIS)

    1982-01-01

    The objective of the revised Training Manual is to help scientists to acquire the necessary knowledge needed for performing proper research and development work in the field of food irradiation. The Manual presents an up-to-date picture of the current state of food irradiation and reflects the important advances made in the technology of food irradiation, in the radiation chemistry of foods, in the microbiology of irradiated foods, in wholesomeness and standardization. It contains the following chapters: (1) Radionuclides and radiation; (2) Radiation detection and measurement; (3) Radiation protection; (4) Radiation chemistry; (5) Effects of radiation on living organisms; (6) Preservation of foods; (7) Radiation preservation of foods; (8) Packaging; (9) Combination processes; (10) Limitations of food irradiation; (11) Wholesomeness of irradiated foods; (12) Government regulation of irradiated foods; (13) Food irradiation facilities; (14) Commercial aspects of food irradiation; (15) Literature sources. The practical part of the Manual contains a revised and expanded series of detailed laboratory exercises in the use of ionizing radiation for food processing

  1. MCNPX simulations of the research gamma irradiator at CTEx

    International Nuclear Information System (INIS)

    Rusin, Tiago; Rebello, Wilson F.; Vellozo, Sergio O.; Gomes, Renato G.; Silva, Ademir X.

    2011-01-01

    An accurate knowledge of the dose rate distribution inside an irradiating facility is needed in order to ensure safety and guarantee efficient treatment of materials by exposure to ionizing radiation, since insufficient doses may not produce the desired effects whereas exceeding ones can compromise the properties of the irradiated items. Described in this work, are Monte Carlo simulations of the cavity-type research irradiating facility at Centro Tecnologico do Exercito performed by using the MCNPX radiation transport code. The calculations were intended to provide a better understanding of the measured dose rate distributions produced by a 42-kCi cesium- 137 source, also modeling unmapped regions of interest, either inside or outside the irradiation chambers, such as in experimental channels, or next to the moveable door and across unmapped regions of the chambers, in order to investigate scattering and attenuation of the fluxes and softening of the gamma spectrum and to predict dose rates in case of an accidental opening of the shielded door with the source out of its shielded cask. Results from calculations have been compared to measurements performed with chemical dosimeters. Comparative analyses have consistently shown a very good agreement between calculated and measured relative dose rate distributions and provided an improved knowledge on the gamma ray environment produced by the irradiator. (author)

  2. MCNPX simulations of the research gamma irradiator at CTEx

    Energy Technology Data Exchange (ETDEWEB)

    Rusin, Tiago; Rebello, Wilson F.; Vellozo, Sergio O.; Gomes, Renato G., E-mail: tiagorusin@ime.eb.b, E-mail: rebello@ime.eb.b, E-mail: vellozo@cbpf.b, E-mail: renatoguedes@ime.eb.b [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Nuclear; Vital, Helio C., E-mail: vital@ctex.eb.b [Centro Tecnologico do Exercito (CTEx), Rio de Janeiro, RJ (Brazil); Silva, Ademir X., E-mail: ademir@con.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear

    2011-07-01

    An accurate knowledge of the dose rate distribution inside an irradiating facility is needed in order to ensure safety and guarantee efficient treatment of materials by exposure to ionizing radiation, since insufficient doses may not produce the desired effects whereas exceeding ones can compromise the properties of the irradiated items. Described in this work, are Monte Carlo simulations of the cavity-type research irradiating facility at Centro Tecnologico do Exercito performed by using the MCNPX radiation transport code. The calculations were intended to provide a better understanding of the measured dose rate distributions produced by a 42-kCi cesium- 137 source, also modeling unmapped regions of interest, either inside or outside the irradiation chambers, such as in experimental channels, or next to the moveable door and across unmapped regions of the chambers, in order to investigate scattering and attenuation of the fluxes and softening of the gamma spectrum and to predict dose rates in case of an accidental opening of the shielded door with the source out of its shielded cask. Results from calculations have been compared to measurements performed with chemical dosimeters. Comparative analyses have consistently shown a very good agreement between calculated and measured relative dose rate distributions and provided an improved knowledge on the gamma ray environment produced by the irradiator. (author)

  3. Identification of Radiation Sources in a Peacetime Environment

    Science.gov (United States)

    1998-04-01

    Radionuclides in Medicine, Research, and Industry (continued) Isotope Symbol Polonium - 210 Po- 210 Promethium-147 Pr-147 Radium-226 Ra-226 Selenium-75 Se...equip- ment seen in a nuclear medicine department or nuclear pharmacy, radia- tion therapy sources, industrial food irradiation facilities, and small... Food Irradiator 28 Commercial Irradiator Facility 28 Appendix 1. Commonly Used Radionuclides in Medicine, Research, and Industry 29 General

  4. The reaction rates of electrons with native and irradiated ribonuclease

    International Nuclear Information System (INIS)

    Schuessler, H.; Ebert, M.; Davies, J.V.

    1977-01-01

    The rate of reaction of hydrated electrons with proteins depends, amongst other things, on the conformational structure of the protein, and irradiation itself causes conformational changes in proteins. A study has been made of variations in the reaction rates of hydrated electrons with RNase pre-irradiated by the Linac or by a 60 Co γ-source. The reaction rate constants varied with the pre-irradiation dose, the concentration of phosphate buffer, the enzyme concentration and also the presence of 10 -2 M ethanol. These variations serve to emphasize the importance of the tertiary structure of biological molecules in irradiation processes and have significant implications in the mathematical analysis of the inactivation of enzymes in steady-state irradiation processes. (U.K.)

  5. Heavy ion irradiation effects of polymer film on absorption of light

    Energy Technology Data Exchange (ETDEWEB)

    Kasai, Noboru; Seguchi, Tadao [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Arakawa, Tetsuhito

    1997-03-01

    Ion irradiation effects on the absorption of light for three types of polymer films; polyethylene-terephthalate (PET), polyethylene-naphthalate (PEN), and polyether-ether-ketone (PEEK) were investigated by irradiation of heavy ions with Ni{sup 4+}(15MeV), O{sup 6+}(160MeV), and Ar{sup 8+}(175MeV), and compared with electron beams(EB) irradiation. The change of absorption at 400nm by a photometer was almost proportional to total dose for ions and EB. The absorption per absorbed dose was much high in Ni{sup 4+}, but rather small in O{sup 6+} and Ar{sup 8+} irradiation, and the absorption by EB irradiation was accelerated by the temperature of polymer film during irradiation. The beam heating of materials during ion irradiation was assumed, especially for Ni ion irradiation. The heavy ion irradiation effect of polymers was thought to be much affected by the ion beam heating than the linear energy transfer(LET) of radiation source. (author)

  6. Modelling a gamma irradiation process using the Monte Carlo method

    International Nuclear Information System (INIS)

    Soares, Gabriela A.; Pereira, Marcio T.

    2011-01-01

    In gamma irradiation service it is of great importance the evaluation of absorbed dose in order to guarantee the service quality. When physical structure and human resources are not available for performing dosimetry in each product irradiated, the appliance of mathematic models may be a solution. Through this, the prediction of the delivered dose in a specific product, irradiated in a specific position and during a certain period of time becomes possible, if validated with dosimetry tests. At the gamma irradiation facility of CDTN, equipped with a Cobalt-60 source, the Monte Carlo method was applied to perform simulations of products irradiations and the results were compared with Fricke dosimeters irradiated under the same conditions of the simulations. The first obtained results showed applicability of this method, with a linear relation between simulation and experimental results. (author)

  7. Modelling a gamma irradiation process using the Monte Carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Gabriela A.; Pereira, Marcio T., E-mail: gas@cdtn.br, E-mail: mtp@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    In gamma irradiation service it is of great importance the evaluation of absorbed dose in order to guarantee the service quality. When physical structure and human resources are not available for performing dosimetry in each product irradiated, the appliance of mathematic models may be a solution. Through this, the prediction of the delivered dose in a specific product, irradiated in a specific position and during a certain period of time becomes possible, if validated with dosimetry tests. At the gamma irradiation facility of CDTN, equipped with a Cobalt-60 source, the Monte Carlo method was applied to perform simulations of products irradiations and the results were compared with Fricke dosimeters irradiated under the same conditions of the simulations. The first obtained results showed applicability of this method, with a linear relation between simulation and experimental results. (author)

  8. Evaluation of irradiation in foods using DNA comet assay

    International Nuclear Information System (INIS)

    Khawar, Affaf; Bhatti, Ijaz Ahmad; Khan, Q.M.; Ali, T.; Khan, A.I.; Asi, M.R.

    2011-01-01

    Comet assay is a rapid, inexpensive and sensitive biological technique to detect DNA damage in food stuffs by irradiation. In this study the Comet assay is applied on foods of plant and animal origins. Samples were irradiated by using 60 Co gamma-radiation source. The applied doses were 2, 6 and 10 kGy for food of plant origin and 0.5, 1 and 2 kGy for meat items. The un-irradiated and irradiated samples were clearly differentiated on the basis of DNA fragmentation. During the electrophoresis study, it was found that in un-irradiated cells DNA remained intact and appeared as Comets without tail whereas in irradiated cells Comets with tails were visible due to stretching of fragmented DNA. Moreover, it was also revealed that the DNA tail length was dose dependent. Dry food stuffs (seeds) showed good results as compared to moist foods (meat, fruits and vegetables) due to the absence of background damage. (author)

  9. Dyeing of γ-irradiated cotton with natural flavonoid dye extracted from irradiated onion shells (Allium cepa) powder

    International Nuclear Information System (INIS)

    Rehman, Fazal-ur; Adeel, Shahid; Shahid, Muhammad; Bhatti, Ijaz Ahmad; Nasir, Faiza; Akhtar, Nasim; Ahmad, Zulfiqar

    2013-01-01

    Powder of Onion shells as a source of natural flavonoid dye (Quercetin) and cotton fabrics were exposed to absorbed doses of 2, 4, 6, 8 and 10 kGy using Cs-137 gamma irradiator. Irradiated and un-irradiated dye powder was used for extraction of quercetin as well as antibacterial, hemolytic and antioxidant activities were also determined to observe the effect of radiation. Furthermore, color strength and colourfastness of irradiated fabrics were improved by using pre and post-mordants such as alum and iron. It is found that 4 kGy is the optimal absorbed dose for extraction of natural quercetin extracted from onion shells while maximum color strength and acceptable fastness properties are obtained on dyeing of irradiated fabric at 60 °C keeping M:L of 1:30 using 10% alum as pre-mordant and 6% alum as post-mordant. Gamma irradiation has not only improved the color strength of the dye using irradiated cotton but also that of colourfastness properties. - Highlights: • The optimal absorbed dose obtained for surface modification of cotton (RC) is 4 kGy. • The optimal absorbed dose for extraction of colorant from onion shell powder (RP) is 4 kGy. • Optimum dying conditions: 60 °C, 1 30 as M:L. • Optimum pre-mordant 10% alum and 6% alum as post-mordant. • At these optimum conditions: color strength and fastness properties are improved

  10. An evaluation of low-energy x-ray and cobalt-60 irradiations of MOS transistors

    International Nuclear Information System (INIS)

    Dozier, C.M.; Fleetwood, D.M.

    1987-01-01

    An evaluation of methodologies for irradiating MOS transistors with low-energy x-ray and Co-60 sources has been performed. The authors find that comparisons of voltage shifts produced by bulk trapped charge and interface states in MOS transistors irradiated using two different low energy x-ray sources (an ARACOR 10 keV W source and an 8 keV Cu source) agree to within better than 30 percent. This quality of agreement is similar in magnitude to that between MOS devices irradiated by different Co-60 sources. In contrast, the measurements indicate that interlaboratory comparisons of ratios of shifts produced by x-ray and Co-60 sources can lead to differences in ratios as large as a factor of --1.7. Improved electron-hole recombination data for oxides is presented. This recombination correction, in conjunction with a correction for interface dose enhancement, is used to predict the ratios of shifts produced by x-ray and Co-60 sources. However, the results show that corrections for electron-hole recombination and interface does enhancement do not, by themselves, adequately predict the field dependent behavior of these transistors

  11. The preliminary study on peculiar flavor from irradiated dried duck

    International Nuclear Information System (INIS)

    Li Zongju; Chen Zongdao; Xu Denyi

    1992-01-01

    Peculiar flavor may be induced from irradiative preservation of meat with higher dose. The study on the irradiation of dried duck indicated that peculiar flavor is produced by a threshold of 1.5 kGy and intensifies with the increase of dose. The flavor primarily comes from muscle of dried duck especially from its water soluble protein. With the increase of dose, volatile carbonyl compounds, amines and sulfur compounds increased significantly. Paper chromatography analysis shows that two new volatile carbonyl compounds (R f =0.23 and 0.28) and a new volatile amine-propamine are induced by irradiation. This compounds may be the source of peculiar flavor in irradiated dried duck

  12. Effect of gamma irradiation on HPMC/ZnO nanocomposite films

    International Nuclear Information System (INIS)

    Rao, B. Lakshmeesha; Asha, S.; Madhukumar, R.; Latha, S.; Gowda, Mahadeva; Shivananda, C. S.; Harish, K. V.; Sangappa; Shetty, G. Rajesha

    2015-01-01

    The present work looks into the structural and mechanical properties modification in ZnO nanoparticle incorporated Hydroxypropyl methylcellulose (HPMC) polymer films, induced by gamma irradiation. The irradiation process was performed in gamma chamber at room temperature by use of Cobalt-60 source (Average energy of 1.25MeV) at different doses: 0, 50, 100, 150 and 200 kGy respectively. The changes in structural parameters and mechanical properties in pure and gamma irradiated HPMC/ZnO nanocomposite films have been studied using X-ray scattering (XRD) data and universal testing machine (UTM). It is found that gamma irradiation decreases the structural parameters and improves the mechanical properties of nanocomposite films

  13. IFMIF - International Fusion Materials Irradiation Facility Conceptual Design Activity/Interim Report

    International Nuclear Information System (INIS)

    Rennich, M.J.

    1995-12-01

    Environmental acceptability, safety, and economic viability win ultimately be the keys to the widespread introduction of fusion power. This will entail the development of radiation- resistant and low- activation materials. These low-activation materials must also survive exposure to damage from neutrons having an energy spectrum peaked near 14 MeV with annual radiation doses in the range of 20 displacements per atom (dpa). Testing of candidate materials, therefore, requires a high-flux source of high energy neutrons. The problem is that there is currently no high-flux source of neutrons in the energy range above a few MeV. The goal, is therefore, to provide an irradiation facility for use by fusion material scientists in the search for low-activation and damage-resistant materials. An accellerator-based neutron source has been established through a number of international studies and workshops' as an essential step for materials development and testing. The mission of the International Fusion Materials Irradiation Facility (IFMIF) is to provide an accelerator-based, deuterium-lithium (D-Li) neutron source to produce high energy neutrons at sufficient intensity and irradiation volume to test samples of candidate materials up to about a full lifetime of anticipated use in fusion energy reactors. would also provide calibration and validation of data from fission reactor and other accelerator-based irradiation tests. It would generate material- specific activation and radiological properties data, and support the analysis of materials for use in safety, maintenance, recycling, decommissioning, and waste disposal systems

  14. Secondary-source energy-dispersive x-ray spectrometer

    International Nuclear Information System (INIS)

    Larsen, R.P.; Tisue, G.T.

    1975-01-01

    A secondary-source energy-dispersive x-ray spectrometer has been built and tested. In this instrument the primary source of x rays is a tungsten-target tube powered by a high-voltage (75 kV), a high-power (3.7 kW) generator from a wavelength spectrometer (G.E. XRD-6). The primary polychromatic x rays irradiate an elemental foil, the secondary source. Its characteristic essentially monochromatic x rays are used to irradiate the sample. Fluorescent x rays from the sample are detected and resolved by a lithium-drifted silicon detector, multichannel-analyzer system. The design of the instrument provides a convenient means for changing the secondary, and hence, the energy of the excitation radiation

  15. A neutron irradiator to perform nuclear activation

    International Nuclear Information System (INIS)

    Zamboni, C. B.; Zahn, G.S.; Figueredo, A. M. G.; Madi, T. F.; Yoriyaz, H.; Lima, R. B.; Shtejer, K.; Dalaqua Jr, L.

    2001-01-01

    The development of appropriate nuclear instrumentation to perform neutron activation analyze (NAA), using thermal and fast neutrons, can be useful to investigate materials outside the reactor premises. Considering this fact, a small size neutron irradiator prototype was developed at IPEN facilities (Instituto de Pesquisas Energeticas e Nucleares - Brazil). Basically, this prototype consists of a cylinder of 1200 mm long and 985 mm diameter (filled with paraffin) with two Am-Be sources (600GBq each) arranged in the longitudinal direction of its geometric center. The material to be irradiated is positioned at a radial direction of the cylinder between the two Am-Be sources. The main advantage of this irradiator is a very stable neutron flux eliminating the use of standard material (measure of the induced activity in the sample by comparative method). This way the process became agile, practical and economic, but quantities at mg levels of samples are necessary to achieve good sensitivity, when the material has a low microscopy neutron cross section. As fast and thermal neutron can be used, the flux distribution, for both, were calculated and the prototype performance is discussed

  16. Stem cell migration after irradiation

    International Nuclear Information System (INIS)

    Nothdurft, W.; Fliedner, T.M.

    1979-01-01

    The survival rate of irradiated rodents could be significantly improved by shielding only the small parts of hemopoietic tissues during the course of irradiation. The populations of circulating stem cells in adult organisms are considered to be of some importance for the homeostasis between the many sites of blood cell formation and for the necessary flexibility of hemopoietic response in the face of fluctuating demands. Pluripotent stem cells are migrating through peripheral blood as has been shown for several mammalian species. Under steady state conditions, the exchange of stem cells between the different sites of blood cell formation appears to be restricted. Their presence in blood and the fact that they are in balance with the extravascular stem cell pool may well be of significance for the surveilance of the integrity of local stem cell populations. Any decrease of stem cell population in blood below a critical size results in the rapid immigration of circulating stem cells in order to restore local stem cell pool size. Blood stem cells are involved in the regeneration after whole-body irradiation if the stem cell population in bone marrows is reduced to less than 10% of the normal state. In the animals subjected to partial-body irradiation, the circulating stem cells appear to be the only source for the repopulation of the heavily irradiated, aplastic sites of hemopoietic organs. (Yamashita, S.)

  17. Beneficial Uses Program. Progress report for period ending June 30, 1978. [Irradiated sewage sludge

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    The Beneficial Uses Program is a comprehensive program to develop the necessary technologies for cost-beneficial uses of existing and future surplus radioactive materials. The major portion of the work at Sandia is concentrated in two sub-programs: the Waste Resources Utilization Program and the Separation Technology and Source Development Program. Progress is reported on: (1) the Sandia Irradiator for Dried Sewage Solids; (2) bacteriology; (3) mycology; (4) virology; (5) animal feeds containing irradiated sewage solids; (6) use of irradiated sewage sludge as fertilizer; and (7) development of /sup 137/Cs radiation sources obtained from radioactive wastes. (TFD)

  18. Dosimetry of a gammabeam 650 60Co irradiator

    International Nuclear Information System (INIS)

    Escobedo, J.F.; Nascimento Filho, V.F.; Barros Ferraz, E.S. de

    1980-01-01

    Fricke and glass dosimetries allowed the determination of some basic irradiation of the γ source Gamma-beam 650, 29,080 Ci of 60 Co on April 1st., 1974 made by Atomic Energy of Canada Limited, in operation at CENA - Piracicaba, Sa o Paulo, Brazil. The number of radioactive capsules in each of the 12 exposure tubes, the uniformity of the activity related to each tube and the mean position of the set of capsules during exposition were determined. The exposure rate at the central point of the internal cavity relatively to the diameter formed by 12 active tubes, were experimentally determined by Fricke dosimetry. The results agreed with those indicated in the operation manual of the irradiator source. (Author) [pt

  19. Evaluation and public acceptance of irradiated strawberries and citrus fruits

    International Nuclear Information System (INIS)

    Del Mastro, Nelida L.; Kikuchi, Olivia K.; Villavicencio, Anna L.C.H.; Sabato, Susy F.; Rela, Paulo R.; Taipina, Magda S.; Mattiolo-Marchse, Sandra R.

    1999-01-01

    Irradiation is a physical process that can be applied to food in order to eliminate microorganisms, insects and other plagues as well as delay ripening or spoilage, thus lengthening its shelf life. In Brazil, the technique is only starting to be applied and is restricted to a few tons of dry or dehydrated food ingredients per year. Strawberry (Fragaria sp.) and citrus are usually attacked by various plagues. Both strawberry and citrus are included in the Brazilian legislation for irradiated foods. This work describes the first sensory trials of 2 varieties of strawberries and 3 varieties of citrus irradiated at IPEN. Irradiation was performed in a panoramic Co-60 source with doses ranging between 1.7 and 4 kGy. Untrained groups of panelists judged the quality of irradiated and non-irradiated control fruits. From the analysis of the results, it was concluded that there no significant differences in the characteristical properties of the fruits when they were irradiated with the doses recommended by the legislation. (author)

  20. Irradiation monitoring of spices by chemiluminescence method

    International Nuclear Information System (INIS)

    Bhatti, K.A.; Khan, H.M.; Sattar, A.; Ahmad, A.

    2001-01-01

    Some spices (cumin, coriander, black pepper and red pepper), commonly used due to their specific aroma and nutritional value were studied using chemiluminescence (CL) method to test whether the food has been irradiated or not. The spices were ground to different mesh sizes and subjected to gamma ray doses of 2.5, 5.0, 7.5 and 10 Kgy. The effect of radiation doses and particle size on the CL response of irradiated and un-irradiated samples was checked using luminol and lucigenin sensitizers. The storage experiment was also performed for all spices with both the sensitizers in order to pick the suitable sensitizer for CL study. During this study Co-60 gamma ray source and Bio-orbit 1250 luminometer were used after precise calibration

  1. Integration of optical imaging with a small animal irradiator

    International Nuclear Information System (INIS)

    Weersink, Robert A.; Ansell, Steve; Wang, An; Wilson, Graham; Shah, Duoaud; Lindsay, Patricia E.; Jaffray, David A.

    2014-01-01

    Purpose: The authors describe the integration of optical imaging with a targeted small animal irradiator device, focusing on design, instrumentation, 2D to 3D image registration, 2D targeting, and the accuracy of recovering and mapping the optical signal to a 3D surface generated from the cone-beam computed tomography (CBCT) imaging. The integration of optical imaging will improve targeting of the radiation treatment and offer longitudinal tracking of tumor response of small animal models treated using the system. Methods: The existing image-guided small animal irradiator consists of a variable kilovolt (peak) x-ray tube mounted opposite an aSi flat panel detector, both mounted on a c-arm gantry. The tube is used for both CBCT imaging and targeted irradiation. The optical component employs a CCD camera perpendicular to the x-ray treatment/imaging axis with a computer controlled filter for spectral decomposition. Multiple optical images can be acquired at any angle as the gantry rotates. The optical to CBCT registration, which uses a standard pinhole camera model, was modeled and tested using phantoms with markers visible in both optical and CBCT images. Optically guided 2D targeting in the anterior/posterior direction was tested on an anthropomorphic mouse phantom with embedded light sources. The accuracy of the mapping of optical signal to the CBCT surface was tested using the same mouse phantom. A surface mesh of the phantom was generated based on the CBCT image and optical intensities projected onto the surface. The measured surface intensity was compared to calculated surface for a point source at the actual source position. The point-source position was also optimized to provide the closest match between measured and calculated intensities, and the distance between the optimized and actual source positions was then calculated. This process was repeated for multiple wavelengths and sources. Results: The optical to CBCT registration error was 0.8 mm. Two

  2. Fine tuning power diodes with irradiation

    International Nuclear Information System (INIS)

    Tarneja, K.S.; Bartko, J.; Johnson, J.E.

    1976-01-01

    Diodes of a particular type are fine tuned with irradiation to optimize the reverse recovery time while minimizing forward voltage drop and providing more uniform electrical characcteristics. The initial and desired minority carrier lifetimes in the anode region of the type are determined as a function of forward voltage drop and reverse recovery time, and the minority carrier radiation damage factor is determined for a desired type of diode and radiation source. The radiation dosage to achieve the desired carrier lifetime with the radiation source is thereafter determined from the function 1/tau = 1/tau 0 + K phi, where tau is the desired minority carrier lifetime, tau 0 is the initial minority carrier lifetime, K is the determined minority carrier radiation damage factor and phi is the radiation dosage. A major surface and preferably the major surface adjoining the anode region of the diodes is then irradiated with the radiation source to the determined radiation dosage. Preferably, the radiation dosage is between about 1 X 10 12 and 5 X 10 13 e/cm 2 , with electron radiation of intensity between 1 and 3 MeV

  3. Food irradiation methodology : prospect and retrospect

    International Nuclear Information System (INIS)

    Nadkarni, G.B.

    1987-01-01

    Research and development work in food irradiation over the past several years has been essentially directed towads answering all possible questions in respect of the suitability of the process, quality of materials and safety for human use. A major effort was indeed, around the toxicological evaluation, till it was recognised internationally that irradiated items of food do not present any health hazards. This recognition along with the awareness of the hazards in the use of chemicals has resulted in a renewed interest in the use of radiations for preservation of food. Radiation preservation of food would reach the stage of practical application with additional information on design and functional aspects of radiation sources, appropriate for specific commodities. Each items has a particular dose requirement depending on the purpose of irradiation and the type of handling. 21 refs. (author)

  4. Some features of irradiated chitosan and its biological effect

    Energy Technology Data Exchange (ETDEWEB)

    Hai, Le; Hien, Nguyen Quoc; Luan, Le Quang; Hanh, Truong Thi; Man, Nguyen Tan; Ha, Pham Thi Le; Thuy, Tran Thi [Nuclear Research Institute, VAEC, Dalat (Viet Nam); Yoshii, Fumio; Kume, Tamikazu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    2001-03-01

    Preparation of chitosan oligomer by radiation degradation was carried out on the gamma Co-60 source. The radiation degradation yield (G{sub d}) of the chitosan was found to be of 1.03. The oligochitosan with 50% of dp>8 fraction was obtained by irradiating the 10% (w/v) chitosan solution in 5% acetic acid at 45 kGy for the chitosan having the initial viscometric average molecular weight, Mv=60,000. Irradiated chitosan showed higher antifungal effect than that of unirradiated one. Furthermore, the irradiated chitosan also showed the growth-promotion effect for plants. (author)

  5. Evaluation by nuclear relaxation of hydrogen tucuman irradiated fruit

    International Nuclear Information System (INIS)

    Lima, Keila dos Santos Cople; Lima, Antonio Luis dos Santos; Araujo, Leandro Moreira; Tavares, Maria Ines Bruno

    2011-01-01

    The tucuman (Astrocarium vulgare Mart.) develops a yellow-orange fibrous pulp and a yellow-green peel as it gets mature. In Brazil it is considered a good source of carotenoids, which is the main precursor of vitamin A. Considering that the irradiation process is an alternative to avoid post-harvesting losses, without changing the nutritional value of food, this study had the objective of evaluating of different gamma irradiation doses (0.0; 0.5; 1.0; 2.0 kGy) in Tucuman samples, divided into control (non irradiated) and irradiated, by the low-field Magnetic Nuclear Resonance (NMR) analysis. The technique is used in quantitative determinations of nondestructively and non-invasive instrumentation employing low, with minimal sample, quickly, preserving its constitution and nature. (author)

  6. Planning a 60Co irradiation facility for fruit preservation

    International Nuclear Information System (INIS)

    Yuan, H.C.

    1978-01-01

    A conceptual design for a conveyor system is proposed for use in fruit irradiation. The seasonal nature of the fruit harvest requires that the 60 Co source inventory should be sufficient to meet the demand at peak season, but this would be excessive at the beginning and towards the end of the harvest. Because of the short crop period the possibility of other irradiation services should be exploited to ensure full utilization of the facility. For successful extension of fruit shelf-life rigid practices in pre-irradiation treatment are essential and careful packaging is indispensable to the operation of the irradiator. Based on the time required for construction and equipment supply, a period of 18 months should be assumed for completion of the project. (author)

  7. Irradiation damage of alkali halide crystals during positron bombardment

    International Nuclear Information System (INIS)

    Arefiev, K.P.; Arefiev, V.P.; Vorobiev, S.A.

    1978-01-01

    The bleaching effect of positron irradiation of KCl and KBr single crystals previously coloured with electrons or protons was investigated. Positrons injection in the coloured alkali halide samples reduced the F-centres concentration considerably. For KCl crystals thicker than the positrons range the appearance of additional bands in the absorption spectra is noticeable. The experimental data show that the bleaching phenomenon should be observed merely throughout the positron exposure both for irradiated and non-irradiated regions of the sample. Irradiation effects, due to positron source, on the peak counting rate of (γ-γ) angular correlation in KCl crystals under applied magnetic field were also investigated. The growth of peak counting rate shows the increase of positronium-like states formation near defects of cation sublattice. (author)

  8. Irradiated fuel by-product separation research in Canada

    International Nuclear Information System (INIS)

    Burston, M.

    1984-01-01

    Although no decision has been made to reprocess irradiated CANDU fuel, by-product separation research has recently been initiated in Canada because of its potential importance to Canadian research programs in advanced fuel cycles (especially U/Pu cycle development in the near term) and nuclear waste management. In addition, separated by-products could have a significant commercial potential. Demonstrated applications include: heat sources, gamma radiation sources, light sources, new materials for productions of other useful isotopes, etc. For illustrative purposes the calculated market value of by-products currently stored in irradiated CANDU fuel is approximately $210/kgU. Ontario Hydro has initiated a program to study the application of new separation technolgies, such as laser-based techniques and the plasma ion cyclotron resonance separation technique, to either augment and/or supplant the chemical extraction methods. The main goal is to develop new, more economical extraction methods in order to increase the magnitude of the advantages resulting from this approach to reprocessing. (author)

  9. Oxidative stability examination of irradiated swine for samples

    International Nuclear Information System (INIS)

    Formanek, Z.

    1995-01-01

    DSC (Differential Scanning Calorimetry), OBM (Oxygen Bomb Method) methods and POV (Peroxide Value) determination was applied to determine the oxidative stability of lard samples irradiated by a Co 60 gamma source at the dose of 0; 0.75; 2.5kGy. Both of the methods seem to be suitable to determine oxidative stability of fats, because in every case lowering oxidative stability was received with increasing irradiation dose. (R.P.). 8 refs., 7 figs., 1 tab

  10. GfW-handbook for irradiation test guidelines for radiation hardness of electronic components

    International Nuclear Information System (INIS)

    Braeunig, D.; Wulf, F.; Gaebler, W.; Boden, A.

    1982-12-01

    The purpose of the report is to propose irradiation test methods so that a standardized application of the methods can lead to a better comparison of test results. The interaction of different radiation species with matter - ionization and displacement - is described. Application of appropriate radiation sources, dosimetry problems, and shielding for simulating space radiation effects by laboratory testing is discussed. The description and characteristics of the irradiation sources are presented. Flowcharts of the planning and running of irradiation tests are given. Guidelines for running the tests are established, test methods and test circuits are proposed. The test system offers the capability of measuring devices also of high complexity up to microprocessors. The test results are collected regularly and are published in GfW-Handbook TN53/08, 'Data Compilation of Irradiation Tested Electronic Components'. (orig./HP) [de

  11. The compositional dependence of irradiation creep of austenitic alloys irradiated in PFR at 420{degrees}C

    Energy Technology Data Exchange (ETDEWEB)

    Toloczko, M.B.; Garner, F.A. [Pacific Northwest National Lab., Richland, WA (United States); Munro, B. [AEA Technology, Dounreay (United Kingdom)] [and others

    1997-04-01

    Irradiation creep data are expensive and often difficult to obtain, especially when compared to swelling data. This requires that maximum use be made of available data sources in order to elucidate the parametric dependencies of irradiation creep for application to new alloys and to new environments such as those of proposed fusion environments. One previously untapped source of creep data is that of a joint U.S./U.K. experiment conducted in the Prototype Fast Reactor (PFR) in Dounreay, Scotland. In this experiment, five austenitic steels were irradiated in a variety of starting conditions. In particular, these steels spanned a large range (15-40%) of nickel contents, and contained strong variations in Mo, Ti, Al, and Nb. Some alloys were solution-strengthened and some were precipitation-strengthened. Several were cold-worked. These previously unanalyzed data show that at 420{degrees}C all austenitic steels have a creep compliance that is roughly independent of the composition of the steel at 2{+-}1 x 10{sup {minus}6}MPa{sup {minus}1} dpa{sup {minus}1}. The variation within this range may arise from the inability to completely separate the non-creep strains arising from precipitation reactions and the stress-enhancement of swelling. Each of these can be very sensitive to the composition and starting treatment of a steel.

  12. Irradiation facilities for materials research: IFMIF and small scale installations

    International Nuclear Information System (INIS)

    Perlado, J. M.; Victoria, M.

    2007-01-01

    The research of advance materials in nuclear fields such as new fission reactors (Generation-IV), Accelerator Driven Systems for Transmutation of Radioactive Wastes and Nuclear Fusion, is becoming very much common in the types of low activation and radiation resistant Materials. Ferritic-Martensitic Steels (based in 9-12 Cr) with or without Oxide Dispersion Techniques (Ytria Nanoparticles), Composites materials are becoming the new generation to answer requirements of high temperature, high radiation resistance of structural materials. Special dedication is appearing in general research programmes to this area of Materials. The understanding of their final performance needs a wider knowledge of the mechanisms of radiation damage in these materials from the atomistic scale to the macroscopic responses. New extensive campaigns are being funded to irradiate from simple elements to model alloys and finally the complex materials themselves. That sequence and its state of art will be presented One clear technique for that understanding is the Multi scale Modelling which includes simulation techniques from quantum mechanics, molecular dynamics, defects diffusion, mesoscopic modelling and finally the macroscopic constitutive relations for macroscopic analysis. However, in each one of these steps is necessary a systematic and well established program of experiments that combines the irradiation and the very detailed analysis with techniques such as Transmission Electron Microscope, Positron Annihilation, SIMS, Atom Probe, Nanoindebntation. A key aspect that wants to be presented in this work is the state of art and discussion of Irradiation Facilities for Materials studies. Those facilities goes from ion implantation sources, small accelerator, Experimental Reactors such High Flux Reactor, sophisticated Triple Beams Sources as JANNUS in France to generate at the same time displacements-hydrogen-helium, and projected very large neutron installation such as IFMIF. The role to

  13. RTNS-II irradiations and operations

    International Nuclear Information System (INIS)

    Logan, C.M.; Heikkinen, D.W.

    1982-01-01

    The objectives of this work are operation of RTNS-II (a 14-MeV neutron source facility), machine development, and support of the experimental program that utilizes this facility. Experimenter services include dosimetry handling, scheduling, coordination, and reporting. RTNS-II is dedicated to materials research for the fusion power program. Its primary use is to aid in the development of models of high-energy neutron effects. Such models are needed in interpreting and projecting to the fusion environment engineering data obtained in other neutron spectra. Irradiations were performed for a total of twenty-nine different experimenters during this quarter. A JOEL 200 CX TEM and other post-irradiation test equipment have been installed

  14. Application of polymers cross-linked by electron beam irradiation to electric wire industry

    International Nuclear Information System (INIS)

    Oda, Eisuke

    1976-01-01

    Applications of the polymers cross-linked by electron beam irradiation to electric wire industry as an example of dully developed utilization are reviewed. The report is divided into five parts, namely 1) radiation sources and irradiation processes, 2) development of crosslinking materials, 3) accumulation of electric charge and accumulation of heat, 4) examples of application, and 5) future prospect. Such a phenomenon as discharge destruction pattern (Lichtenberg figure) must be solved, when cable insulation materials are cross-linked by electron beam irradiation. The measures for preventing the discharge destruction are required, especially when the layers of polyethylene insulation for high voltage cables are irradiated. The accumulation of heat causes the troubles in foaming, degeneration and wire running of high potential cables, when the layers of insulation are thick. Effective promoters for cross-linking must be studied to reduce the radiation dose. The irradiators capable of irradiating wires uniformly are desirable. Electron beam accelerators will be used, as far as the radiation dose of 10 or more Mrad is required for cross-linking irradiation. If the dose of one tenth or less of the above value is required, gamma-ray sources (RI) are rather easily applicable than focused strong beam. The utilization of spent nuclear fuel is desirable. (Iwakiri, K.)

  15. Tropical Fruit Irradiation-From Research to Commercial Application

    International Nuclear Information System (INIS)

    Moy, James H.

    2005-09-01

    Food irradiation is an emerging technology for the 21st century. Extensive research and development worldwide in the past 40 years have proved the versatility and efficacy. With low, medium to high dose, and using either a gamma, electrons, or x-ray source, radiation can: 1) disinfest plant products and spices; 2) extend shelf life of tubers, bulbs, and selected tropical fruits; 3) decontaminate meats and seafood; 4) sterilize spices and special meals; and 5) improve product utilization. Criteria for testing its efficacy include effectiveness, efficiency, and the ability to retain product quality. The use of irradiation as a quarantine treatment of tropical fruits is potentially attractive to countries growing these fruits. A two-prong research plan should aim at proving radiation's effectiveness in preventing emergence of all insect pests that might be on a fruit, and determining that all quality attributes of a host fruit are retained after irradiation, subsequent storage and shipment. ommercial application involves conducting an economical feasibility study; market research and testing; selection of radiation source and irradiator type; training of personnel for plant operations, radiation safety and dosimetry monitoring; designing of packages and choosing the most cost-effective means of transporting treated fruits to market destinations. When all of hese are achieved, it should lead to a continuous and profitable operation. Researchers at the University of Hawaii using a gamma irradiator from the mid-1960s to early 2000s had amassed a volume of data to prove the efficacy of radiation disinfestations. And installation of a commercial x-ray irradiator in 2000 on the Island of Hawaii has enabled fruit farmers and packers to use this technology for exporting tropical fruits to distant markets

  16. Shielding evaluation of moving bed onion irradiator by radiometry

    International Nuclear Information System (INIS)

    Venkataramani, R.; Sangurdekar, P.R.; Sarangapani, R.; Raipurkar, D.R.; Mehta, S.K.; Shastri, S.P.; Patil, K.B.; Bongirwar, D.R.

    1994-01-01

    A moving bed onion irradiator made from m.s. cladded lead slab shields designed to hold 20 kCi of 60 Co source was evaluated by radiometry with an 8 Ci 60 Co source from CRC-2 radiography camera. Some shielding losses in the irradiator noted by radiometry could be visualized by a thermocole model of the complex shielding assembly. These were rectified by appropriate lead filling. Significant shielding losses noted at cladding layer positions of slabs were attributed to lack of interlocking features in the slabs. These had to be rectified by provision of 3 TVL of additional all round shielding supplemented by local shielding at some positions. (author). 1 fig., 1 tab

  17. Optimization of source pencil deployment based on plant growth simulation algorithm

    International Nuclear Information System (INIS)

    Yang Lei; Liu Yibao; Liu Yujuan

    2009-01-01

    A plant growth simulation algorithm was proposed for optimizing source pencil deployment for a 60 Co irradiator. A method used to evaluate the calculation results was presented with the objective function defined by relative standard deviation of the exposure rate at the reference points, and the method to transform two kinds of control variables, i.e., position coordinates x j and y j of source pencils in the source plaque, into proper integer variables was also analyzed and solved. The results show that the plant growth simulation algorithm, which possesses both random and directional search mechanism, has good global search ability and can be used conveniently. The results are affected a little by initial conditions, and improve the uniformity in the irradiation fields. It creates a dependable field for the optimization of source bars arrangement at irradiation facility. (authors)

  18. Effect of gamma irradiation and cooking on cowpea bean grains (Vigna unguiculata L. Walp)

    Energy Technology Data Exchange (ETDEWEB)

    Santos Cople Lima, Keila dos, E-mail: keila@ime.eb.br [Nuclear Engineering Department, Military Institute of Engineering, Rio de Janeiro/RJ, Praca General Tiburcio, 80, CEP 22290-270 Rio de Janeiro/RJ (Brazil); Boher e Souza, Luciana [Nuclear Engineering Department, Military Institute of Engineering, Rio de Janeiro/RJ, Praca General Tiburcio, 80, CEP 22290-270 Rio de Janeiro/RJ (Brazil); Oliveira Godoy, Ronoel Luiz de [Technological Center, Embrapa Food Agroindustry, Av. das Americas, 29501, CEP 23020-470 Rio de Janeiro/RJ (Brazil); Costa Franca, Tanos Celmar; Santos Lima, Antonio Luis dos [Chemical Engineering Department, Military Institute of Engineering, Praca General Tiburcio, 80, CEP 22290-270 Rio de Janeiro/RJ (Brazil)

    2011-09-15

    Leguminous plants are important sources of proteins, vitamins, carbohydrates, fibers and minerals. However, some of their non-nutritive elements can present undesirable side effects like flatulence provoked by the anaerobic fermentation of oligosaccharides, such as raffinose and stachyose, in the gut. A way to avoid this inconvenience, without any change in the nutritional value and post-harvesting losses, is an irradiation process. Here, we evaluated the effects of gamma irradiation on the amino acids, thiamine and oligosaccharide contents and on the fungi and their toxin percentages in cowpea bean (Vigna unguiculata L. Walp) samples. For irradiation doses of 0.0, 0.5, 1.0, 2.5, 5.0 and 10.0 kGy the results showed no significant differences in content for the uncooked samples. However, the combination of irradiation and cooking processes reduced the non-nutritive factors responsible for flatulence. Irradiation also significantly reduced the presence of Aspergillus, Penicilium, Rhizopus and Fusarium fungi and was shown to be efficient in grain conservation for a storage time of 6 months. - Highlights: > In this study we evaluated cowpea beans subjected to different doses of gamma irradiation > Cowpea bean grains represent an important source of vegetal protein for Brazilian population. > Non-nutritive factors were reduced by irradiation and cooking. > Several genera of fungus were reduced by irradiation without affecting the nutritional content. > Irradiation helps the cooking process preserving thermosensible nutrients.

  19. Design of unique pins for irradiation of higher actinides in a fast reactor

    International Nuclear Information System (INIS)

    Basmajian, J.A.; Birney, K.R.; Weber, E.T.; Adair, H.L.; Quinby, T.C.; Raman, S.; Butler, J.K.; Bateman, B.C.; Swanson, K.M.

    1982-03-01

    The actinides produced by transmutation reactions in nuclear reactor fuels are a significant factor in nuclear fuel burnup, transportation and reprocessing. Irradiation testing is a primary source of data of this type. A segmented pin design was developed which provides for incorporation of multiple specimens of actinide oxides for irradiation in the UK's Prototype Fast Reactor (PFR) at Dounreay Scotland. Results from irradiation of these pins will extend the basic neutronic and material irradiation behavior data for key actinide isotopes

  20. Overview of the FUTURIX-FTA Irradiation Experiment in the Phénix Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Heather J.M. Chichester; Steve L. Hayes; Kenneth J. McClellan; Jean-Luc Paul; Marc Masson; Stewart L. Voit; Fabienne Delage

    2015-09-01

    The Advanced Fuels Campaign utilizes the Advanced Test Reactor (ATR) for most of its irradiation testing. Cadmium-shrouded baskets are used in ATR to modify the neutron spectrum to simulate a fast reactor environment for the fuel. FUTURIX-FTA is an irradiation experiment conducted in the Phenix fast reactor in France. Results from FUTURIX-FTA and irradiation tests in ATR using identical fuel compositions will be compared to identify and evaluate any differences in fuel behavior due to differences in the irradiation source.

  1. System control for the modulated 252Cf source ''Shuffler''

    International Nuclear Information System (INIS)

    Stephens, M.M.

    1975-06-01

    The design and theory of operation of the control chassis for a 252 Cf nondestructive assay system are described. This system repetitively transfers a 252 Cf source from the irradiation region to a shielded position before measuring the delayed neutrons. The design criteria for the system were: rapid movement and precise positioning of the 252 Cf source, precise positioning of the sample, and very accurate timing of the irradiate and count cycles. To achieve these results crystal oscillators were used for timing, and stepping motors were used to position the sample and the source. (U.S.)

  2. The preliminary study on peculiar flavor from irradiated dried duck

    Energy Technology Data Exchange (ETDEWEB)

    Zongju, Li; Zongdao, Chen; Denyi, Xu [Southwest Agricultural Univ., Chongqing, SC (China)

    1992-11-01

    Peculiar flavor may be induced from irradiative preservation of meat with higher dose. The study on the irradiation of dried duck indicated that peculiar flavor is produced by a threshold of 1.5 kGy and intensifies with the increase of dose. The flavor primarily comes from muscle of dried duck especially from its water soluble protein. With the increase of dose, volatile carbonyl compounds, amines and sulfur compounds increased significantly. Paper chromatography analysis shows that two new volatile carbonyl compounds (R[sub f] =0.23 and 0.28) and a new volatile amine-propamine are induced by irradiation. This compounds may be the source of peculiar flavor in irradiated dried duck.

  3. FORMATION OF S-BEARING SPECIES BY VUV/EUV IRRADIATION OF H2S-CONTAINING ICE MIXTURES: PHOTON ENERGY AND CARBON SOURCE EFFECTS

    International Nuclear Information System (INIS)

    Chen, Y.-J.; Juang, K.-J.; Qiu, J.-M.; Chu, C.-C.; Yih, T.-S.; Nuevo, M.; Jiménez-Escobar, A.; Muñoz Caro, G. M.; Wu, C.-Y. R.; Fung, H.-S.; Ip, W.-H.

    2015-01-01

    Carbonyl sulfide (OCS) is a key molecule in astrobiology that acts as a catalyst in peptide synthesis by coupling amino acids. Experimental studies suggest that hydrogen sulfide (H 2 S), a precursor of OCS, could be present in astrophysical environments. In the present study, we used a microwave-discharge hydrogen-flow lamp, simulating the interstellar UV field, and a monochromatic synchrotron light beam to irradiate CO:H 2 S and CO 2 :H 2 S ice mixtures at 14 K with vacuum ultraviolet (VUV) or extreme ultraviolet (EUV) photons in order to study the effect of the photon energy and carbon source on the formation mechanisms and production yields of S-containing products (CS 2 , OCS, SO 2 , etc.). Results show that (1) the photo-induced OCS production efficiency in CO:H 2 S ice mixtures is higher than that of CO 2 :H 2 S ice mixtures; (2) a lower concentration of H 2 S enhances the production efficiency of OCS in both ice mixtures; and (3) the formation pathways of CS 2 differ significantly upon VUV and EUV irradiations. Furthermore, CS 2 was produced only after VUV photoprocessing of CO:H 2 S ices, while the VUV-induced production of SO 2 occurred only in CO 2 :H 2 S ice mixtures. More generally, the production yields of OCS, H 2 S 2 , and CS 2 were studied as a function of the irradiation photon energy. Heavy S-bearing compounds were also observed using mass spectrometry during the warm-up of VUV/EUV-irradiated CO:H 2 S ice mixtures. The presence of S-polymers in dust grains may account for the missing sulfur in dense clouds and circumstellar environments

  4. Investigation on the effects of gamma irradiation on bitumen

    International Nuclear Information System (INIS)

    Mello, M.S.; Braz, D.; Motta, L.M.G.

    2011-01-01

    Brazil has more than 218,000 km of asphalt-paved highways. Bitumen is a generic term for natural or manufactured black or dark-colored solid, semisolid, or viscous cementitious materials that are composed mainly of high molecular weight hydrocarbons (90-95%). Several papers have shown that the irradiation process has changed the mechanical behavior in some polymers. This work aims to analyze the behavior of Brazilian irradiated Bitumen (CAP 50-70). In order to provide a preliminary evaluation, bitumen samples and cylindrical specimens of asphaltic mixture were tested. The bitumen samples were irradiated 0.1 to 300 kGy, and asphaltic mixture specimen was irradiated 5 to 300 kGy. The cylindrical asphaltic mixture specimen of 10.16 cm diameter used in this study was molded using an asphalt-aggregate mixture. The specimens were irradiated in LIN/UFRJ/Brazil using a Gamma cell Co 60 source of gamma irradiation with an applied dose rate of 29.7 Gy/min. After irradiated, the bitumen samples were subjected to penetration test and the asphaltic mixtures were subjected to indirect tensile strength test (diametral compression) for determination of the resilient modulus, according to ASTM method D 4123. The results of these experiments for each dose were compared with the control (nonirradiated). As expected, the penetration results showed that the ratio (irradiated/non-irradiated) decreases with increasing of irradiation dose for bitumen samples and the resilient modulus results showed that the ratio (irradiated/non-irradiated) increases with increasing of irradiation dose for asphaltic mixture. (author)

  5. Food Irradiation. Proceedings of the International Symposium on Food Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1966-11-15

    of perishable food products. Different radiation sources, particularly {sup 60}Co and electron accelerators, can be used. Different types of foodstuffs react differently: ripening is delayed in some fruit, the cooking time of dehydrated vegetables can be shortened, and the shelf life of fish and some varieties of fruit and vegetables can be more than doubled. The applicability of irradiation depends on economic factors, as well as on climatic, technological, transport and food-growing conditions in given areas. The main subjects covered at the Symposium were: radiation sources and dosimetry, the wholesomeness of irradiated food, the chemical and physical effects of ionizing radiation, microbiology, virology and quarantine problems, the status of various irradiated commodities, including meat and meat products, poultry and eggs, grain and stored food products, fish and sea foods, and fruit and vegetables. In the broader application of radiation to food preservation, the participants discussed present programmes in operation, facilities used, and economics, together with national legislation and clearances for irradiated items. Some countries are already using radiation for the prevention of sprouting in potatoes and onions and for the sterilization of bacon. In the near future its use for the disinfestation of grain will be implemented. The irradiation of food - described as the first truly novel food preservation method since Nicolas Appert well over one hundred years ago invented food preservation by bottling - will doubtless play a very important role in the life of mankind, in many instances in conjunction with conventional food treatment methods, such as heat and refrigeration.

  6. Food Irradiation. Proceedings of the International Symposium on Food Irradiation

    International Nuclear Information System (INIS)

    1966-01-01

    of perishable food products. Different radiation sources, particularly 60 Co and electron accelerators, can be used. Different types of foodstuffs react differently: ripening is delayed in some fruit, the cooking time of dehydrated vegetables can be shortened, and the shelf life of fish and some varieties of fruit and vegetables can be more than doubled. The applicability of irradiation depends on economic factors, as well as on climatic, technological, transport and food-growing conditions in given areas. The main subjects covered at the Symposium were: radiation sources and dosimetry, the wholesomeness of irradiated food, the chemical and physical effects of ionizing radiation, microbiology, virology and quarantine problems, the status of various irradiated commodities, including meat and meat products, poultry and eggs, grain and stored food products, fish and sea foods, and fruit and vegetables. In the broader application of radiation to food preservation, the participants discussed present programmes in operation, facilities used, and economics, together with national legislation and clearances for irradiated items. Some countries are already using radiation for the prevention of sprouting in potatoes and onions and for the sterilization of bacon. In the near future its use for the disinfestation of grain will be implemented. The irradiation of food - described as the first truly novel food preservation method since Nicolas Appert well over one hundred years ago invented food preservation by bottling - will doubtless play a very important role in the life of mankind, in many instances in conjunction with conventional food treatment methods, such as heat and refrigeration.

  7. Localized irradiations, evaluation through 'Comet Assay'

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Taja, Maria R.; Nasazzi, Nora B.; Bustos, N.; Cavalieri, H.; Bolgiani, A.

    2000-01-01

    During the last 50 years various radiation accidents involving localized irradiations occurred, resulting mainly from improper handling of sealed sources of Cobalt 60, Cesium 137 or Iridium 192 at work placed for industrial gammagraphy and other radiation sources. Severe skin reaction may developed at the contact sites. Such inhomogeneous irradiations lead to a differential exposure of lymphocytes in lymphatic tissues or other organs that may recirculate into the peripheral blood producing a mixed irradiated and unirradiated population of lymphocytes. Applying the mathematical models 'Contaminated Poisson' of Dolphin and Qdr method of Sasaki, a mean dose in the irradiated body area and its size can be estimated from unstable chromosome aberration scoring. There are also different biophysical techniques that can give response in localized irradiations. Biological dosimetry is a necessary complement to physical and clinical dosimetries. Thus, there is increasing interest in the assessment of biological markers that permit the detection of radiation induced damage in the localized irradiations. The 'Comet Assay' (single cell gel electrophoresis) is a sensitive, rapid and relatively inexpensive method for measuring DNA damage in individual cells. Single cells are embedded in agarose on microscope slides, lysed to remove the majority of the proteins, electrophoresed, then stained with ethidium bromide in order to visualize the DNA. When visualized using a fluorescent microscope, DNA of undamaged cells appears as a spherical mass occupying the cavity formed by the lysed cell. Following radiation damage, the smaller the fragment size and the grater the number of fragments of DNA, the grater the percentage of DNA that it is able to migrate in an electric field, forming a comet image. The assay can be performed under alkaline conditions to examine DNA single strand breaks (SSBs), or in non denaturing (neutral) conditions to measure double strand breaks (DSBs) in individual

  8. Gamma irradiation for sewage treatment at US army facilities

    International Nuclear Information System (INIS)

    Van den Berg, A.J.; Hollis, H.D.; Musselman, H.D.; Woodbridge, D.D.

    1975-01-01

    The US Army Corps of Engineers has been sponsoring research for many years on the use of gamma irradiation for disinfection and sterilization of sewage plant effluents. Initial research was directed to laboratory experiments using sterile solutions to determine the effects of gamma irradiation on E. coli, M-pyogenes and M-smegmatis organisms, and on the chemical constituents of sewage such as phenols, surfactants and pesticides. The results of the initial research warranted further study using municipal sewage secondary effluent as test samples. Current research is directed towards investigating the effects of radiation on the constituents of sewage sludge and on the cyst stage of the amoebic protozoa. Consideration has been given by the Corps to the management of waste-waters by disposal on land. Legal and medical reasons dictate that the plant effluents be sterilized before being used as fertilizers and soil conditioners. Gamma radiation from isotopic sources appears to be the best source of sterilizing energy for Army waste-water disposal. The Corps of Engineers is considering the construction of an experimental gamma irradiation pilot facility to validate laboratory experimental work and to establish design criteria for operating plants. The data obtained will provide a basis for performing detailed cost effectiveness studies on gamma irradiation as a method to treat secondary plant effluent. In addition, optimization work will be conducted to determine where in the sewage treatment cycle the use of gamma irradiation will produce the best results in meeting current and anticipated standards. (author)

  9. Current status of food irradiation in the world. Trend in Asia

    International Nuclear Information System (INIS)

    Kume, Tamikazu

    2002-01-01

    This review describes the current status of food irradiation in the world and particularly, its trends in Asia, based on the report of the economic scale investigation on the irradiation in United States and Japan (2001) and on the information of 12th International Meeting on Radiation Processing in France in 2001 and on personal communications. International Consultative Group on Food Irradiation promotes its activities of irradiation globally and 46 countries are affiliated. Food irradiation is allowed in 52 countries. In 1999, 257,000 t of food is irradiated in the world, of which 1/3 is due to spice. The facilities for the irradiation have such sources as 60 Co and 137 Cs γ-rays, electron beam of <10 MeV and X-ray with <5 MeV. Detection methods of irradiated foods are summarized by the project of Analytical Detection Methods for Irradiation Treatment of Foods. The US is the most advanced country in the irradiation and, in Japan, only irradiation of potato is permitted. The detailed present status is also described of Bangladesh, China (the irradiation is most widely conducted in the world), India, Indonesia, Korea, Malaysia, Thailand and Vietnam. Recently Australia and New Zealand have started the irradiation. (K.H.)

  10. On enzyme kinetic parameters modification of gamma irradiation

    International Nuclear Information System (INIS)

    Ferdes, O.S.; Ferdes, M.; Turcu, G.R.

    1993-01-01

    To elucidate the molecular mechanisms of gamma-ray action on biomolecules there were investigated the modifications in activity and other kinetic parameters for some enzymes irradiated in pure dry state at relative high doses. There were considered bacterial and fungal α-amylases, glucoamylase and Mucor sp. protease irradiated by a 60 Co gamma-ray source in the dose range 1.0-30.0 kGy, at different dose-rates between 0.5-2.0 kGy/h, at room temperature. Considering the enzyme inactivation in this dose range, the dose-effect relationships have an expected form and depend on the irradiation conditions but not significantly on the dose rate. The catalytic properties of enzymes were modified by irradiation. By usual methods it is evidenced a direct correlation between the enzymatic activities, Michaelis-Menten constant, K m , reaction velocities, v, and the irradiation dose. These experimental findings can support a self-consistent theoretical approach on biophysical radiation action on biological active molecules like enzymes. At the same time, some enzyme behaviour to irradiation could be considered like a good biological indicator of radiation response. (Author) 4 Figs., 19 Refs

  11. Growth analysis of UV-B-irradiated cucumber seedlings as influenced by photosynthetic photon flux source and cultivar

    International Nuclear Information System (INIS)

    Krizek, D.T.; Mirecki, R.M.; Kramer, G.F.

    1994-01-01

    A growth analysis was made of ultraviolet-B (UV-B)-sensitive (Poinsett) and insensitive (Ashley) cultivars of Cucuumis satives L. grown in growth chambers at 600 μmol m −2 s −1 of photosynthetic photon flux (PPF) provided by red- and far-red-deficient metal halide (MH) or blue- and UV-A-deficient high pressure sodium/deluxe f HPS/DX) lamps. Plants were irradiated 6 h daily with 0.2 f-UV-B) or 18.2 C+UV-B) kJ m −2 day −1 of biologically effective UV-B for 8 or 15 days from time of seeding. In general, plants given supplemental UV-B for 15 days showed lower leaf area ratio (LARs, and higher specific leaf mass (SLM) mean relative growth rate (MRGR) and net assimilation rate (NAR) than that of control plants, but they showed no difference in leaf mass ratio (LMR), Plants grown under HPS/DX lamps vs MH lamps showed higher SLM and NAR. lower LAR and LMR. hut no difference in MRGR. LMR was the only growth parameter affected by cultivar: at 15 days, it was slightly greater in Poinsett than in Ashley. There were no interactive effects of UV-B. PPF source or cultivar on any of the growth parameters determined, indicating that the choice of either HPS/DX or MH lamps should not affect growth response to UV-B radiation. This was true even though leaves of UV-B-irradiated plants grown under HPS/DX lamps have been shown to have greater chlorosis than those grown under MH lamps. (author)

  12. Tissue glycogen and blood glucose in irradiated rats. II

    International Nuclear Information System (INIS)

    Ahlersova, E.; Ahlers, I.; Praslicka, M.

    1980-01-01

    Male rats of the Wistar strain were continuously irradiated with 0.57 Gy (60 R) of gamma rays from a 60 Co source. Irradiation lasted from 1 to 50 days in an experimental field where also control animals shielded from radiation were placed. After a 16 h starvation, the concentration of glucose in the blood and of glycogen in the liver and the heart was determined 1, 3, 7, 14, 21, 25, 32, 39 and 50 days after the beginning of irradiation. The concentration of blood glucose in irradiated rats did not practically differ from that of control animals during the whole period of investigation. The concentration of liver glycogen in irradiated animals was higher than that in the controls during all time intervals, except for day 1. The values of glycogen in the heart muscle were approximately identical in the irradiated and control rats, except for day 21 when they sharply increased in the irradiated animals. In addition to the investigation of blood glucose and tissue glycogen during continuous irradiation, these parameters were studied immediately, and 1, 6 and 12 months after continuous irradiation with a daily exposure of 0.57 Gy (60 R) up to a total exposure of 14.35 Gy (1500 R) of gamma rays. Considerably higher values of liver glycogen were detected in the irradiated rats immediately, and 1 and 6 months after the end of irradiation. (author)

  13. Detection of irradiated spice in blend of irradiated and un-irradiated spices using thermoluminescence method

    International Nuclear Information System (INIS)

    Goto, Michiko; Yamazaki, Masao; Sekiguchi, Masayuki; Todoriki, Setsuko; Miyahara, Makoto

    2007-01-01

    Five blended spice sample were prepared by mixing irradiated and un-irradiated black pepper and paprika at different ratios. Blended black pepper containing 2%(w/w) of 5.4 kGy-irradiated black pepper showed no maximum at glow1. Irradiated black pepper samples, mixed to 5 or 10%(w/w), were identified as 'irradiated' or 'partially irradiated' or 'un-irradiated'. All samples with un-irradiated pepper up to 20%(w/w) were identified as irradiated'. In the case 5.0 kGy-irradiated paprika were mixed with un-irradiated paprika up to 5%(w/w), all samples were identified as irradiated'. The glow1 curves of samples, including irradiated paprika at 0.2%(w/w) or higher, exhibited a maximum between 150 and 250degC. The results suggest the existence of different critical mixing ratio for the detection of irradiation among each spices. Temperature range for integration of the TL glow intensity were compared between 70-400degC and approximate 150-250degC, and revealed that the latter temperature range was determined based on the measurement of TLD100. Although TL glow ratio in 150-250degC was lower than that of 70-400degC range, identification of irradiation was not affected. Treatment of un-irradiated black pepper and paprika with ultraviolet rays had no effect on the detection of irradiation. (author)

  14. 1-Chloronaphthalene decomposition in air using electron beam irradiation

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Sun, Y.; Bulka, S.; Zimek, Z.

    2006-01-01

    A method for the preparation of model gas containing 1-chloronaphthalene can be referred to 1,1-DCE (dichloroethene). A pulsed electron beam (EB) accelerator ILU-6 (2.0 MeV max., 20 kW max.) was used as an irradiation source. The absorbed dose rate inside the irradiation vessel was 10.835 kGy/min. Total absorbed dose was adjusted by changing irradiation time of the Pyrex glass vessels. 1-Chloronaphthalene concentration was analyzed using gas-chromatography. It has been found, that 1-chloronaphthalene can be decomposed in air or N 2 using EB irradiation. Decomposition efficiency of 1-chloronaphthalene in air is higher than that in N 2 . Positive charge transfer reactions and OH radicals' reaction may play a main role in 1-chloronaphthalene decomposition process

  15. Whole-Genome Sequencing in Microbial Forensic Analysis of Gamma-Irradiated Microbial Materials.

    Science.gov (United States)

    Broomall, Stacey M; Ait Ichou, Mohamed; Krepps, Michael D; Johnsky, Lauren A; Karavis, Mark A; Hubbard, Kyle S; Insalaco, Joseph M; Betters, Janet L; Redmond, Brady W; Rivers, Bryan A; Liem, Alvin T; Hill, Jessica M; Fochler, Edward T; Roth, Pierce A; Rosenzweig, C Nicole; Skowronski, Evan W; Gibbons, Henry S

    2016-01-15

    Effective microbial forensic analysis of materials used in a potential biological attack requires robust methods of morphological and genetic characterization of the attack materials in order to enable the attribution of the materials to potential sources and to exclude other potential sources. The genetic homogeneity and potential intersample variability of many of the category A to C bioterrorism agents offer a particular challenge to the generation of attributive signatures, potentially requiring whole-genome or proteomic approaches to be utilized. Currently, irradiation of mail is standard practice at several government facilities judged to be at particularly high risk. Thus, initial forensic signatures would need to be recovered from inactivated (nonviable) material. In the study described in this report, we determined the effects of high-dose gamma irradiation on forensic markers of bacterial biothreat agent surrogate organisms with a particular emphasis on the suitability of genomic DNA (gDNA) recovered from such sources as a template for whole-genome analysis. While irradiation of spores and vegetative cells affected the retention of Gram and spore stains and sheared gDNA into small fragments, we found that irradiated material could be utilized to generate accurate whole-genome sequence data on the Illumina and Roche 454 sequencing platforms. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  16. Philosophy of regulating on food irradiation and its trend in USA

    Energy Technology Data Exchange (ETDEWEB)

    Kauffman, F L [Food and Drug Administration, Washington, DC (USA)

    1984-01-01

    The irradiation for the treatment of certain foods has been investigated since late 1940s, and the limited application has been permitted for a number of years in the United States. But, there has been relatively little commercialization of this process. The research conducted so far indicated that the following areas would be promising for the initial utilization: hygienization of spices, the control of insect infestation in fruits, the control of foodborne germs, the prolongation of fruit storage life, etc. On the other hand, the irradiated food regulations by the Food and Drug Administration have proceeded as follows: the source of irradiation was determined to be a food additive - 1958, the labeling of irradiated products was required - 1966, the advance notice of the proposed rule-making for irradiated foods was published - 1981, the irradiation of spices was approved - 1983.

  17. Functional properties of irradiated starch

    International Nuclear Information System (INIS)

    Laouini, Wissal

    2011-01-01

    Irradiation is an effective method capable of modifying the functional properties of starches. Its effect depends on the specific structural and molecular organization of starch granules from different botanical sources. In this study, we have studied the effect of gamma irradiation (3, 5, 10, 20, 35, 50 kGy) on the rheological properties of some varieties of starch (potato, cassava and wheat). First, we were interested in determining dry matter content; the results showed that the variation in dry matter compared to the control (native starch) is almost zero. So it does not depend on the dose of irradiation. Contrariwise, it differs from a botanical species to another. The viscometer has shown that these starches develop different behaviors during shearing. The native potato starch gave the highest viscosity followed by wheat and cassava which have almost similar viscosities. For all varieties, the viscosity of starch decreases dramatically with an increasing dose of irradiation. At high doses (35 and 50 kGy) the behavior of different starch is similar to that of a viscous pure liquid. The textural analysis via the back-extrusion test showed that increasing the dose of radiation causes a decrease in extrusion force and the energy spent of the different starch throughout the test. Indeed, the extrusion resistance decreases with increasing dose.

  18. Internal irradiation for cystic craniopharyngioma

    International Nuclear Information System (INIS)

    Kobayashi, T.; Kageyama, N.; Ohara, K.

    1981-01-01

    The authors report the results of internal irradiation with labeled chromic phosphate (32P) and gold-198 (198Au) colloid in eight cases of cystic craniopharyngiomas. They used a newly developed dosimetric formula, by which the radiation dose at the cyst wall and at any point far from the radioactive source can be calculated. Ten courses of irradiation in eight patients were carried out by injection of either 32P or 198Au colloid into the cyst through an Ommaya drainage system that had been placed at craniotomy. Follow-up studies ranging from 13 to 156 months revealed that all cysts were effectively treated, with elimination of fluid or collapse of the cyst. This was confirmed by Conray cystography and/or computerized tomography. Not only the dose delivered to the wall but also the thickness of the cyst wall and the location of the cyst are important factors in planning internal irradiation. A safe and adequate dose to the cyst wall could range between 9000 to 30,000 rads for craniopharyngioma. This treatment is suitable for large cysts that are thought to be difficult to remove radically, recurrent cysts resistant to previous treatment, or multiple cysts. Internal irradiation may also be applicable in other cystic intracranial tumors if dosimetry is calculated accurately

  19. Fast neutron irradiation tests of flash memories used in space environment at the ISIS spallation neutron source

    Directory of Open Access Journals (Sweden)

    C. Andreani

    2018-02-01

    Full Text Available This paper presents a neutron accelerated study of soft errors in advanced electronic devices used in space missions, i.e. Flash memories performed at the ChipIr and VESUVIO beam lines at the ISIS spallation neutron source. The two neutron beam lines are set up to mimic the space environment spectra and allow neutron irradiation tests on Flash memories in the neutron energy range above 10 MeV and up to 800 MeV. The ISIS neutron energy spectrum is similar to the one occurring in the atmospheric as well as in space and planetary environments, with intensity enhancements varying in the range 108- 10 9 and 106- 10 7 respectively. Such conditions are suitable for the characterization of the atmospheric, space and planetary neutron radiation environments, and are directly applicable for accelerated tests of electronic components as demonstrated here in benchmark measurements performed on flash memories.

  20. Fast neutron irradiation tests of flash memories used in space environment at the ISIS spallation neutron source

    Science.gov (United States)

    Andreani, C.; Senesi, R.; Paccagnella, A.; Bagatin, M.; Gerardin, S.; Cazzaniga, C.; Frost, C. D.; Picozza, P.; Gorini, G.; Mancini, R.; Sarno, M.

    2018-02-01

    This paper presents a neutron accelerated study of soft errors in advanced electronic devices used in space missions, i.e. Flash memories performed at the ChipIr and VESUVIO beam lines at the ISIS spallation neutron source. The two neutron beam lines are set up to mimic the space environment spectra and allow neutron irradiation tests on Flash memories in the neutron energy range above 10 MeV and up to 800 MeV. The ISIS neutron energy spectrum is similar to the one occurring in the atmospheric as well as in space and planetary environments, with intensity enhancements varying in the range 108- 10 9 and 106- 10 7 respectively. Such conditions are suitable for the characterization of the atmospheric, space and planetary neutron radiation environments, and are directly applicable for accelerated tests of electronic components as demonstrated here in benchmark measurements performed on flash memories.

  1. Enhancement of electrical conductivity in gamma irradiated cobalt ferrite nanoparticles

    International Nuclear Information System (INIS)

    Nawpute, Asha A.; Raut, A.V.; Babrekar, M.K.; Kale, C.M.; Jadhav, K.M.; Shinde, A.B.

    2014-01-01

    The cobalt ferrite nanoparticles were synthesized by sol-gel auto- combustion method, in which L-ascorbic acid was used as a fuel. The effect of gamma irradiation on the electrical resistivity of cobalt ferrite nanoparticles has been studied. The ferrite powder annealed at 550℃ was irradiated by gamma source 137 Cs. The synthesized nanoparticles were characterized by X-ray diffraction and DC resistivity. (author)

  2. Cs-137 for irradiation of sewage sludge

    International Nuclear Information System (INIS)

    Lessel, T.

    1986-01-01

    Since 1973, the Geiselbullach sewage treatment works have been continuously operating their first system for gamma irradiation of sewage sludge. Within the framework of a German-American agreement, nine Cs-137 sources with a total activity of 56.000 Ci have been made available to the works free of charge in 1983, in order to test in practice and to demonstrate the applicability of these radiation sources in comparison to the Co-60 sources exclusively used up to then. This first study on the applicability of Cs-137 as a radiation source for sewage sludge treatment revealed no findings or effects speaking against Cs-137 as a radiation source for this purpose. (orig./RB) [de

  3. Practice for dosimetry for a self-contained dry-storage gamma-ray irradiator

    International Nuclear Information System (INIS)

    2002-01-01

    This practice outlines dosimetric procedures to be followed with self-contained dry-storage gamma-ray irradiators. If followed, these procedures will help to ensure that calibration and testing will be carried out with acceptable precision and accuracy and that the samples processed with ionizing radiation from gamma rays in a self-contained dry-storage irradiator receive absorbed doses within a predetermined range. This practice covers dosimetry in the use of dry-storage gamma-ray irradiators, namely self-contained dry storage 137 Cs or 60 Co irradiators (shielded free-standing irradiators). It does not cover underwater pool sources, panoramic gamma-ray sources such as those raised mechanically or pneumatically to irradiate isotropically into a room or through a collimator, nor does it cover self-contained bremsstrahlung x-ray units. The absorbed dose range for the use of the dry-storage self-contained gamma-ray irradiators covered by this practice is typically 1 to 10 5 Gy, depending on the application. The absorbed-dose rate range typically is from 10 -2 to 10 3 Gy/min. This practice describes general procedures applicable to all self-contained dry-storage gamma-ray irradiators. For procedures specific to dosimetry in blood irradiation, see ISO/ ASTM Practice 51939. For procedures specific to dosimetry in radiation research on food and agricultural products, see ISO/ASTM Practice 51900. For procedures specific to radiation hardness testing, see ASTM Practice E 1249. For procedures specific to the dosimetry in the irradiation of insects for sterile release programs, see ISO/ASTM Guide 51940. In those cases covered by ISO/ASTM Practices 51939, 51900, 51940, or ASTM E 1249, those standards take precedence. In addition, this practice does not cover absorbed-dose rate calibrations of radiation protection instrumentation

  4. Design, Construction, and Modeling of a 252Cf Neutron Irradiator

    Directory of Open Access Journals (Sweden)

    Blake C. Anderson

    2016-01-01

    Full Text Available Neutron production methods are an integral part of research and analysis for an array of applications. This paper examines methods of neutron production, and the advantages of constructing a radioisotopic neutron irradiator assembly using 252Cf. Characteristic neutron behavior and cost-benefit comparative analysis between alternative modes of neutron production are also examined. The irradiator is described from initial conception to the finished design. MCNP modeling shows a total neutron flux of 3 × 105 n/(cm2·s in the irradiation chamber for a 25 μg source. Measurements of the gamma-ray and neutron dose rates near the external surface of the irradiator assembly are 120 μGy/h and 30 μSv/h, respectively, during irradiation. At completion of the project, total material, and labor costs remained below $50,000.

  5. Development and production of cobalt-60 sources for metallurgical application

    International Nuclear Information System (INIS)

    Oliveira, Paulo Fernando; Valente, Eduardo Sarmento; Maretti Junior, Fausto

    2002-01-01

    The CDTN has developed and produced 60 Co sources to be used in level controllers on continuous ingot casting. The sources used in these systems are sealed with a stainless steel revetment and have an useful life equivalent to one half life of the 60 Co (5.272 years). Each system of continuous ingot casting uses a source with one specified activity and different activation section. The sources have been imported with a very high cost due the special shields used to keep and transport them safety. One of its sources, with initial activity of 148 MBq, after being used for more than 5 years in one factory, was given to CDTN to carry out an activation section studies. After these studies be concluded CDTN/CNEN began the procedures to produce a new source in the IPR-R1 TRIGA Reactor, with an irradiation of one cobalt wire in the maximum flux region of the core. The same metallic cobalt wire was irradiated (10% of total activity), to determinate the necessary irradiation time to obtain the final activation. The CDTN developed too a stainless steel recipient with a aluminum nucleus, to seal and to guarantee the integrity of the source. (author)

  6. A new fully integrated X-ray irradiator system for dosimetric research

    International Nuclear Information System (INIS)

    Richter, D.; Mittelstraß, D.; Kreutzer, S.; Pintaske, R.; Dornich, K.; Fuchs, M.

    2016-01-01

    A fully housed X-ray irradiator was developed for use within lexsyg or Magnettech desktop equipment. The importance of hardening of the low energy photon radiation is discussed, its performance and feasibility is empirically shown and sustained by basic numerical simulations. Results of the latter for various materials are given for different X-ray source settings in order to provide estimates on the required setup for the irradiation of different geometries and materials. A Si-photodiode provides real-time monitoring of the X-ray-irradiator designed for use in dosimetric dating and other dosimetric application where irradiation of small samples or dosemeters is required. - Highlights: • Bench top X-ray irradiator provides variable dose-rates. • Simulation of low energy photon irradiation and hardening of X-ray. • Al-hardening for the irradiation of H_2O, BeO, Al_2O_3, quartz, feldspars and zircon. • Dosimetric dating equipment for luminescence and ESR.

  7. Dose Profiles in ECAL Crystals for Various Irradiation Conditions

    CERN Document Server

    Huhtinen, Mika

    1998-01-01

    Simulated dose profiles in various irradiation and beam test conditions are compared to the expected dose profiles in the ECAL crystals at LHC. Simple front or side irradiations with photons give too steep or too flat dose profiles, respectively. Thus, if dose maxima are fitted to agree, front irradiation underestimate the average dose whereas side irradiations tend to overestimate. Different profiles are difficult to compare reliably, but it seems likely that in both cases the discrepancy is about a factor of 2-3 but in different directions. For most purposes this is likely to be good enough, but should be taken into account in the interpretation of the test results. It is shown that using a customized lead mask between the source and the crystal can significantly improve the agreement between 60 Co side irradiations and the LHC predictions. A 400 MeV/c pion beam incident on a crystal matrix can also reproduce rather well the profiles expected in the barrel ECAL.

  8. Production of radioisotopic gamma radiation sources in JAERI

    International Nuclear Information System (INIS)

    Katoh, Hisashi; Kogure, Hiroto; Suzuki, Kyohei

    1980-04-01

    The present state of production of gamma radiation sources in Japan Atomic Energy Research Institute (JAERI) is described. Sources of 192 Ir, 60 Co and 170 Tm for industrial and 198 Au and 192 Ir for medical applications are produced and delivered routinely by JAERI. Prefabricated assembly targets are irradiated in JRR-2, JRR-3, JRR-4 or JMTR. The irradiated targets are disassembled in a heavy density concrete cave or a lead-shielded cell, depending on the level of radioactivity. The yield of radioactivity in each target is measured with the aid of an ionization chamber. Where necessary, irradiated targets are encapsulated hermetically in capsules of aluminium, stainless steel or other material. The yield of radioactivity is estimated in relation with the burn-up of target nuclide and product nuclide. (author)

  9. Safety of industrial irradiation plants

    International Nuclear Information System (INIS)

    1992-01-01

    Radiation is nowadays used in many applications in industry and medicine; accidental exposure, however, can have grave consequences as large doses of radiation occur in the 600 accelerator or gamma source plants in use around the world. This film explains the operation of irradiation plants and the safety procedures that must be followed to prevent accidents and to ensure safe use

  10. Sensitivity of the different developmental stages of Callosobruchus maculatus to gamma irradiation

    International Nuclear Information System (INIS)

    Olaifa, J.I.; Adebayo, T.A.; Adesanmi, C.A.; Salau, A.M.

    1990-01-01

    Life stages of the cowpea seed beetle (Callosobruchus maculatus F.) were γ irradiated from a 60 Co source. Arrested development was observed at dosages of 1.0, 4.0, 10.0 and 10.0 Gy in the egg, 1st, 2nd, 3rd and 4th larvae stages respectively while 4.0 Gy induced sterility. Longevity of 2-day old adults was not affected by irradiation of 100 Gy. Preservation of cowpeas by irradiation is discussed. (author)

  11. Irradiation in industrial waste treatment

    Energy Technology Data Exchange (ETDEWEB)

    Perkowski, J. (Politechnika Lodzka (Poland). Katedra Chemii Radiacyjnej); Kos, L.; Rouba, J. (Research and Development Centre of the Knitting Industry, Lodz (Poland))

    1984-09-01

    In this paper, the treatment by irradiation of some surface active agents (SAA) contained in aqueous solutions and industrial wastes, has been shown. Studies were carried out on selected SAA, namely Rokafenol N-6 and Pretepon G-extra, representatives of nonionic and anionic SAA, respectively. The aqueous solutions of these compounds were irradiated in radiation chamber, at the Institute of Applied Radiation Chemistry, in Lodz Polytechnic. Co/sup 60/ was used as a source of radiation. The kinetics and degree of destruction of these compounds at the doses ranging from 2 kGy to 110 kGy were investigated. The study was extended to attempts to remove SAA from textile effluents. Reduction of other parameters of contamination, including measurements of toxicity, were also evaluated.

  12. Studies of neutron irradiation effects at IPNS-REF

    International Nuclear Information System (INIS)

    Kirk, M.A.

    1983-09-01

    Neutron irradiation effects studies at the Radiation Effects Facility (REF) at the Intense Pulsed Neutron Source (IPNS) located at Argonne National Laboratory (ANL) are reviewed. A brief history of the development of this user facility is followed by an overview of the scientific program. Experiments unique to a spallation neutron source are covered in more detail. Future direction of research at this facility is suggested

  13. Food processing with electrically generated photon irradiation

    International Nuclear Information System (INIS)

    Matthews, S.M.

    1985-01-01

    Economic constraints require that a food irradiation processing facility have a throughput of approximately 1 MGy ton/day (0.91 MGy m.t./day) requiring 3 MegaCuries (MCi) of cobalt-60 at each site. This requirement means that the total world amount of cobalt-60 would have to be increased by about 60 percent just to handle the California almond and raisin crop during peak season. It is doubtful that public opinion would allow the increased distribution of radioactive isotopes, with the resultant burden upon the transportation networks, as a price to be paid to eat irradiated food. Electric sources have characteristics that allow the production of more penetrating, uniform, and efficient radiation that is available from nuclear isotopes. The heart of the electric radiation source is the electron accelerator. At present, there are no accelerators commercially available that can meet the requirements for food irradiation processing. However, the U.S. Department of Defense-funded beam weapons programs have provided a very promising accelerator technology at the Lawrence Livermore National Laboratory. If this technology were to be commercialized, it appears that the required accelerators would be available for US$1.5 million apiece, and quite possibly for less than this amount. A conceptual design for a portable electric food irradiation processing machine is presented and analyzed for cost, assuming the required accelerators are available for $1.5 million each. It is shown that food can be processed for 1 kGy for a price of $5.98/ton ($6.59/m.t.)

  14. Performance of the ALIBAVA portable readout system with irradiated and non-irradiated microstrip silicon sensors

    International Nuclear Information System (INIS)

    Marco-Hernadez, R.

    2009-01-01

    A readout system for microstrip silicon sensors has been developed as a result of collaboration among the University of Liverpool, the CNM of Barcelona and the IFIC of Valencia. The name of this collaboration is ALIBAVA and it is integrated in the RD50 Collaboration. This system is able to measure the collected charge in one or two microstrip silicon sensors by reading out all the channels of the sensor(s), up to 256, as an analogue measurement. The system uses two Beetle chips to read out the detector(s). The Beetle chip is an analogue pipelined readout chip used in the LHCb experiment. The system can operate either with non-irradiated and irradiated sensors as well as with n-type and p-type microstrip silicon sensors. Heavily irradiated sensors will be used at the SLHC, so this system is being to research the performance of microstrip silicon sensors in conditions as similar as possible to the SLHC operating conditions. The system has two main parts: a hardware part and a software part. The hardware part acquires the sensor signals either from external trigger inputs, in case of a radioactive source setup is used, or from a synchronised trigger output generated by the system, if a laser setup is used. This acquired data is sent by USB to be stored in a PC for a further processing. The hardware is a dual board based system. The daughterboard is a small board intended for containing two Beetle readout chips as well as fan-ins and detector support to interface the sensors. The motherboard is intended to process the data, to control the whole hardware and to communicate with the software by USB. The software controls the system and processes the data acquired from the sensors in order to store it in an adequate format file. The main characteristics of the system will be described. Results of measurements acquired with n-type and p-type irradiated and non-irradiated detectors using both the laser and the radioactive source setup will be also presented and discussed

  15. Effect of irradiation on analgesia induced by morphine and endorphin

    International Nuclear Information System (INIS)

    Kim, Jin Kyu; Lee, Byoung Hun; Hyun, Soung Hee; Chung, Ki Myung

    2003-01-01

    Morphine and endorphin administered intracerebroventricularly (i.c.v.) produce analgesia by activating different descending pain inhibitory systems. Gamma irradiation attenuates the acute analgesic action of i.c.v. injected morphine in mice. This study was done to investigate the effect of-irradiation on the analgesia produced by i.c.v. injected morphine and endorphin in male ICR mice. In one group, mice were exposed to whole-body irradiation at a dose of 5 Gy from a 60 Co source and the analgesic effects were tested 5, 30, 60, 90 and 180 min after irradiation using the acetic acid-induced writhing test. The analgesic effect was produced time-dependently and reached its maximum at 90 min after irradiation. Thus, time was fixed in the following studies. In another group, mice were irradiated with 5 Gy and tested 90 minutes later for analgesia produced by i.c.v. administration of morphine or endorphin. Irradiation significantly potentiated the analgesia produced by endorphin. However, the antinociception produced by morphine was not affected by irradiation. These results support the hypothesis that morphine and endorphin administered supraspinally produce antinocieception by different neuronal mechanisms

  16. Effect of irradiation on analgesia induced by morphine and endorphin

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Kyu; Lee, Byoung Hun; Hyun, Soung Hee; Chung, Ki Myung [KAERI, Daejeon (Korea, Republic of)

    2003-07-01

    Morphine and endorphin administered intracerebroventricularly (i.c.v.) produce analgesia by activating different descending pain inhibitory systems. Gamma irradiation attenuates the acute analgesic action of i.c.v. injected morphine in mice. This study was done to investigate the effect of-irradiation on the analgesia produced by i.c.v. injected morphine and endorphin in male ICR mice. In one group, mice were exposed to whole-body irradiation at a dose of 5 Gy from a {sup 60}Co source and the analgesic effects were tested 5, 30, 60, 90 and 180 min after irradiation using the acetic acid-induced writhing test. The analgesic effect was produced time-dependently and reached its maximum at 90 min after irradiation. Thus, time was fixed in the following studies. In another group, mice were irradiated with 5 Gy and tested 90 minutes later for analgesia produced by i.c.v. administration of morphine or endorphin. Irradiation significantly potentiated the analgesia produced by endorphin. However, the antinociception produced by morphine was not affected by irradiation. These results support the hypothesis that morphine and endorphin administered supraspinally produce antinocieception by different neuronal mechanisms.

  17. Dosimetry concepts and measurements in food irradiation processing

    International Nuclear Information System (INIS)

    Chadwick, K.H.; Oosterheert, W.F.

    1986-01-01

    The associations between the dosimetry concepts, Minimum absorbed dose (Dsub(min)), maximum absorbed dose (Dsub(max), and average dose and median dose are investigated for the case of a large cobalt-60 plaque source irradiating homogeneous bulk product in a two-pass, two-sided irradiation. It is assumed that to a first approximation the intensity of radiation decreases exponentially with the depth, t, in the product. A series of mathematical relationships is derived for the average dose, the maximum and minimum dose, the median dose [defined as (Dsub(maX) + Dsub(min)/2], and the uniformity ratio (defined U.R. = (Dsub(max)/Dsub(min). The relationships are derived in terms of a constant D 0 (the dose on the surface of the products in the pass close to the source) and the relaxation length (μt) of the radiation in the product. Since the uniformity ratio and other dose parameters can be calculated for certain chosen values of μt, the individual values Dsub(min) to Dsub(max) into 10 equal fractions, the amount of product irradiated to each of the fractions is calculated and it is shown that, independent of the value of U.R., about a third of the product receives a dose in the first fraction above Dsub(min). It is also shown that for a given median dose, the average dose decreases as U.R. increases. The calculated dose relationships are confirmed by measurement in homogeneous dummy product, using the lyoluminescence of glutamine to measure dose. The implications of these results for the regulation of the food irradiation process and for the design of irradiation facilities are discussed. (author)

  18. Progress in food irradiation: United States of America

    Energy Technology Data Exchange (ETDEWEB)

    Brynjolfsson, A [Army Natick Research and Development Command, MA (USA). Food Engineering Lab.

    1978-12-01

    On 20 pages, a detailed situation report on the research- and development level of irradiation of several foodstuffs, radio-microbiology, dosimetry, and the radiation sources used is given. The Radio-chemical alterations are explored at model systems.

  19. Intestinal uptake of bile acids: effect of external abdominal irradiation

    International Nuclear Information System (INIS)

    Thomson, A.B.R.; Cheeseman, C.I.; Walker, K.

    1984-01-01

    Abdominal irradiation has recently been shown to influence the uptake of hexoses, amino acids, fatty acids and cholesterol into the jejunum of rats. The present studies were undertaken with a previously validated in vitro technique to determine the effect of abdominal irradiation from a cesium source on the rates of uptake of six bile acids into the jejunum, ileum, and colon. The results show that: 1) there likely are multiple ileal carriers for bile acids: 2) abdominal irradiation has a variable effect on these carriers; 3) the passive permeability to bile acids varies with the bile acid and with the site along the intestine; and 4) abdominal irradiation is associated with a rise in the colonic permeability to only some bile acids

  20. Electrical properties of irradiated PVA film by using ion/electron beam

    Science.gov (United States)

    Abdelrahman, M. M.; Osman, M.; Hashhash, A.

    2016-02-01

    Ion/electron beam bombardment has shown great potential for improving the surface properties of polymers. Low-energy charged (ion/electron) beam irradiation of polymers is a good technique to modify properties such as electrical conductivity, structural behavior, and their mechanical properties. This paper reports on the effect of nitrogen and electron beam irradiation on the electrical properties of polyvinyl alcohol (PVA) films. PVA films of 4 mm were exposed to a charged (ion/electron) beam for different treatment times (15, 30, and 60 minutes); the beam was produced from a dual beam source using nitrogen gas with the other ion/electron source parameters optimized. The dielectric loss tangent tan δ , electrical conductivity σ , and dielectric constant ɛ ^' } in the frequency range 100 Hz-100 kHz were measured at room temperature. The variation of dielectric constant and loss tangent as a function of frequency was also studied at room temperature. The dielectric constant was found to be strongly dependent on frequency for both ion and electron beam irradiation doses. The real (ɛ ^' }) and imaginary (ɛ ^' ' }) parts of the dielectric constant decreased with frequency for all irradiated and non-irradiated samples. The AC conductivity showed an increase with frequency for all samples under the influence of both ion and electron irradiation for different times. Photoluminescence (PL) spectral changes were also studied. The formation of clusters and defects (which serve as non-radiative centers on the polymer surface) is confirmed by the decrease in the PL intensity.

  1. Industrial Irradiation of Polymers: Systems and Concepts

    International Nuclear Information System (INIS)

    Mittendorfer, J.

    2006-01-01

    This paper provides a systematic survey of systems and concepts used in the industrial irradiation of polymers. It consists basically of three parts: in the first part, different types of applications like wires and cables, pipes and engineering plastics are discussed and the associated irradiation systems analyzed and highlighted according their basics modules. These are identified as the radiation source, the product handling system, process control and facility/shielding layout. In the second part, the irradiation process design is reviewed in detail. The discussion starts with the requirement analysis, e.g. the desired polymer parameters and effects, continues with a process development roadmap and concludes with process verification and validation. Special attention is drawn to process control, which plays an important role in industrial irradiation technology. The use of mathematical modeling to facilitate and support process and system design is discussed as well and several examples are given which demonstrate their capabilities. In the third part, the design of a electron beam facility for the irradiation of small plastic parts for the automotive industry is worked out in detail. Besides system and product handling considerations, throughput and economical estimates are provided. The paper concludes with a summary of the design and concept bullets which proved to be important in history and can facilitate new developments which will enhance the potential of industrial polymer irradiation

  2. Food irradiation in Romania - Achievements and expectations

    International Nuclear Information System (INIS)

    Ferdes, O.S.

    1993-01-01

    Irradiation or ionization of foodstuffs and agricultural products is an efficient but controversial method which can lead to the post-harvest spoilages reduction, the extension of shelf-life and to provide the food safety. This paper presents the status of food irradiation research and technologies in our country, and throughout the world, too. In Romania the food processing by irradiation (ionization) is not used for commercial purposes and there are not food irradiation plants, yet. There have been performed only research and pilot-experiments, only by the Institute of Food Research in co-operation and using the 6 0C o gamma-ray sources of the Institute of Chemical and Pharmaceutical Research and the Institute of Physics and Nuclear Engineering, both from Bucharest. These experiments have referred both to the basic aspects of the ionizing radiation interactions with the food essential constituents and to the technological aspects of irradiation from different items like: potatoes, onions, garlic, grain, cereals, wheat flour, fresh and dehydrated fruits and vegetables, mushrooms, meat, eggs, spices, ingredients, and biotechnological products. There are also presented the advantages and disadvantages of food irradiation, the world trends in this field and the future in Romania of this technology which was named, in 1989, by the Institute of Food Technologies (US), t he most versatile technology of the 20 -th Century, for tomorrow . (Author)

  3. Neutron irradiation of bacteriophage λ

    International Nuclear Information System (INIS)

    Bozin, D.; Milosevic, M. . E-mail address of corresponding author: bozinde@vin.bg.ac.yu

    2005-01-01

    Double strand breaks (DSB) are the most dangerous lesions in DNA caused by irradiation, but many other lesions, usually called mutations, have not been clearly identified. These lesions, like DSB, can be the source of serious chromosomal damages and finally - cell death. Growing interest in heavy particles for radiotherapy and radioprotection encourages the search of the molecular basis of their action. In this respect, we chose bacteriophage λ1390 as the model system for the study of consequences of neutron irradiation. This derivative of λ phage possesses an unique ability to reversibly reorganize their genome in response to various selective pressures. The phages were irradiated with 13 Gy of mixed neutrons (7.5 Gy from fast and 5.6 Gy from thermal neutrons) and phages genomes were tested to DSB and mutations. Additionally, the stability of λ capsid proteins were tested. After all tests, we can conclude that, under our conditions, low flux of neutrons does not induce neither DNA strand break or DNA mutation nor the stability of λ capsid proteins. (author)

  4. Coloring of Topaz After Irradiation

    International Nuclear Information System (INIS)

    Salama, S.; Helal, A.I.; Gomaa, M.A.M.; Abou-Salem, L.I.; Nafie, H.; Badawi, E.A.

    2011-01-01

    Raw topaz stone samples are subjected to irradiation by neutrons from the Egyptian research reactor and by γ rays from a gamma source. Changes in the color of the stones are observed which can be attributed to the formation of defects in the structure of the stones. The defects can absorb certain wave length which is observed as a change in the stone color .The absorption of light is investigated by an optical spectrophotometer technique at different irradiation and heating conditions. Raman studies of topaz stones showed a relation between the color changes with changes in the intensities of the band of scattered peaks corresponding to OH group stretching modes of vibration.Positron Annihilation Spectroscopy (PAS) technique is used to study the behavior of defect concentration in topaz in two states; pure and irradiated stones by neutrons and γ. It has been shown that positrons are trapped in imperfect locations in topaz samples and their mean lifetime can be influenced by changes in the concentration of such defects.

  5. Contribution to the development of the MARS beamline to study oxide dispersion strengthened steels (ODS) irradiated with neutrons using synchrotron source: secondary phases evolution under irradiation

    International Nuclear Information System (INIS)

    Menut, Denis

    2016-01-01

    X-Ray Diffraction (XRD) coupled with X-ray Absorption Fine Structure (XAFS) analyses at the MARS beamline of the synchrotron SOLEIL facility were used to study the microstructural evolution of oxides phases found in oxide dispersion strengthened steels (ODS) irradiated in Material Testing Reactors. Two hold generations of ODS steel grades (DY and MA957) irradiated up to high fluencies (∼75 dpa) were studied. These experiments have required specific developments, in particular a dedicated sample holder. An important milestone was overcome integrating the MARS beamline to the nuclearized facilities accessible for CEA. First, XRD analysis provide new results concerning intermediate sizes of precipitates (around 100 nm) essentially from crystallographic point of view, the nano-sized oxides (from 1 to 10 nm) being not detected, due to the material itself, sample preparation as thin foil and experimental set-up calibration. Secondly, XAFS analysis is not a discriminating technique as soon as the absorber atom is involved in the chemical composition of various precipitates found in ODS. Nevertheless, the stability of the Ti with a coordination number of 5 is evidenced whatever the irradiation conditions. As our experimental study was not able to detect the nano-sized oxides, an alternative way is to perform modeling approach of the behavior of massive oxides under irradiation, compared to experimental analyses under ion irradiations. We have shown that the defect fluorite is an intermediate phase of the crystal-to-amorphous phase transition of the pyrochlore oxide structure, whatever the irradiation conditions and the ratio of the cationic radii, the Ti coordination number remaining around 5 in the amorphous state. (author) [fr

  6. Proceedings of the Seminar 'Irradiation Technologies and the IRASM Facility'

    International Nuclear Information System (INIS)

    Ponta, Corneliu Catalin; Moise, Ioan Valentin

    1999-01-01

    The seminar devoted to 'Irradiation Technologies and the IRASM Facility' aimed at debating the principal problems related to one of the most important project ever developed in Romania, at the Horia Hulubei National Institute of Physics and Nuclear Engineering, in collaboration with IAEA. IRASM (an acronym for Multiple Purpose Irradiation Facility) is using initially a 60 Co of 100 kCi irradiation source (to be replaced after an promotional stage by a 2 MCi Co source). It is designed to irradiate a materials volume of about 35,000 m 3 /year. Health, agriculture, food industry and materials industry are the most targeted customers. It will be used for sterilization of medical materials and pharmaceuticals products, peat and seed (and other agricultural products) decontamination and sterilization, experimental irradiation of food products, irradiation of composite plastics and other industrial products, etc. The seminar was a first meeting of Romanian specialists in radiation processing with potential users of these technologies as well as with decision making persons working with national governmental and regulation authorities. Twelve communications were presented as a basis for discussion. These were: 1. IRASM - a technical assistance IAEA project and the prospects for technological irradiation in Romania (Serban Dobrescu); 2. IRASM facility - goal, present stage, perspectives (Corneliu C. Ponta); 3. Nuclear safeguards and radioprotection at IRASM (Ioan Valentin Moise); 4. Nuclear safeguard policy for IRASM (Mariana Irimia, Gabriela Vladescu, Ion Cristian); 5. Technological dosimetry at IRASM (Rodica Macrin, Rodica Moraru, Nicolae Valcov); 6. Quality assurance in building and exploiting IRASM (Ioana Domsa); 7. Current status of irradiation technologies in IFIN-HH (Mitica Dragusin); 8. Chemical-pharmaceutical, cosmetic and medical product sterilization (Paul Adrian, Eleonora Gheorghiu); 9. The concept of sterilization and the sterilization testing (Ileana Petcu

  7. Installation and measurement capacity of 3 x 592 GBq 241Am-Be neutron irradiation cell

    International Nuclear Information System (INIS)

    Bulut, Serdar; Celenk, I.

    2013-01-01

    In this study, the installation and measurement capacity of the neutron irradiation system are investigated. First of all an irradiation geometry enabling optimum irradiation was designed for three 241 Am-Be sources each of it having 592 GBq activity. Neutron irradiation system was installed after design and optimization of the system including the design of appropriate moderator and shielding were completed. Radiation safety standards of the Neutron Research Laboratory fulfilling the requirements of national regulation were achieved with unique configuration of the shielding materials. In this study the results of qualitative and quantitative detection limits obtained for Na, Al, Cl, K, Ti, V, Mn, Fe, Co, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Mo, Ru, Ag, Cd, In, Sb, I, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Dy, Ho, Yb, Lu, Hf, W, Pt, Au, Th and U elements by using the neutron irradiation cell comprising 3 x 592 GBq 241 Am-Be isotopic neutron source are presented and discussed. (orig.)

  8. Stochastic Short-term High-resolution Prediction of Solar Irradiance and Photovoltaic Power Output

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M. [ORNL; Olama, Mohammed M. [ORNL; Dong, Jin [ORNL; Djouadi, Seddik M. [ORNL; Zhang, Yichen [University of Tennessee, Knoxville (UTK), Department of Electrical Engineering and Computer Science

    2017-09-01

    The increased penetration of solar photovoltaic (PV) energy sources into electric grids has increased the need for accurate modeling and prediction of solar irradiance and power production. Existing modeling and prediction techniques focus on long-term low-resolution prediction over minutes to years. This paper examines the stochastic modeling and short-term high-resolution prediction of solar irradiance and PV power output. We propose a stochastic state-space model to characterize the behaviors of solar irradiance and PV power output. This prediction model is suitable for the development of optimal power controllers for PV sources. A filter-based expectation-maximization and Kalman filtering mechanism is employed to estimate the parameters and states in the state-space model. The mechanism results in a finite dimensional filter which only uses the first and second order statistics. The structure of the scheme contributes to a direct prediction of the solar irradiance and PV power output without any linearization process or simplifying assumptions of the signal’s model. This enables the system to accurately predict small as well as large fluctuations of the solar signals. The mechanism is recursive allowing the solar irradiance and PV power to be predicted online from measurements. The mechanism is tested using solar irradiance and PV power measurement data collected locally in our lab.

  9. Moessbauer study of defects in molybdenum and chromium irradiated with ions

    International Nuclear Information System (INIS)

    Troyan, V.A.; Bogdanov, V.V.; Ivanyushkin, E.M.; Pen'kov, Yu.P.

    1980-01-01

    Effects of ion irradiation of monocrystalline molybdenum and polycrystalline chromium with Co-57 impurity were studied by Moessbauer effect. Molybdenum specimens were irradiated by He + ions at accelerators with 40 keV energy. Chromium specimens were irradiated by hydrogen ions with 1.2 MeV energy up to integral 2x10 17 -2x10 19 ion/cm 2 doses. It is shown, that defect introduction into the source matrix by irradiation results in change of gamma-resonance line form and effect value. The observed effects of defect influence on spectrum parameters are discussed. It is concluded, that study of Moessbauer spectra parameters of diluted Co-57 solutions in matrices of different metals permits to determine dynamics of movement of impurity atoms and defects in metals irradiated with ions [ru

  10. Luminescence imaging of water during alpha particle irradiation

    Science.gov (United States)

    Yamamoto, Seiichi; Komori, Masataka; Koyama, Shuji; Toshito, Toshiyuki

    2016-05-01

    The luminescence imaging of water using the alpha particle irradiation of several MeV energy range is thought to be impossible because this alpha particle energy is far below the Cerenkov-light threshold and the secondary electrons produced in this energy range do not emit Cerenkov-light. Contrary to this consensus, we found that the luminescence imaging of water was possible with 5.5 MeV alpha particle irradiation. We placed a 2 MBq of 241Am alpha source in water, and luminescence images of the source were conducted with a high-sensitivity, cooled charge-coupled device (CCD) camera. We also carried out such imaging of the alpha source in three different conditions to compare the photon productions with that of water, in air, with a plastic scintillator, and an acrylic plate. The luminescence imaging of water was observed from 10 to 20 s acquisition, and the intensity was linearly increased with time. The intensity of the luminescence with the alpha irradiation of water was 0.05% of that with the plastic scintillator, 4% with air, and 15% with the acrylic plate. The resolution of the luminescence image of water was better than 0.25 mm FWHM. Alpha particles of 5.5 MeV energy emit luminescence in water. Although the intensity of the luminescence was smaller than that in air, it was clearly observable. The luminescence of water with alpha particles would be a new method for alpha particle detection and distribution measurements in water.

  11. Luminescence imaging of water during alpha particle irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Komori, Masataka; Koyama, Shuji [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Toshito, Toshiyuki [Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center (Japan)

    2016-05-21

    The luminescence imaging of water using the alpha particle irradiation of several MeV energy range is thought to be impossible because this alpha particle energy is far below the Cerenkov-light threshold and the secondary electrons produced in this energy range do not emit Cerenkov-light. Contrary to this consensus, we found that the luminescence imaging of water was possible with 5.5 MeV alpha particle irradiation. We placed a 2 MBq of {sup 241}Am alpha source in water, and luminescence images of the source were conducted with a high-sensitivity, cooled charge-coupled device (CCD) camera. We also carried out such imaging of the alpha source in three different conditions to compare the photon productions with that of water, in air, with a plastic scintillator, and an acrylic plate. The luminescence imaging of water was observed from 10 to 20 s acquisition, and the intensity was linearly increased with time. The intensity of the luminescence with the alpha irradiation of water was 0.05% of that with the plastic scintillator, 4% with air, and 15% with the acrylic plate. The resolution of the luminescence image of water was better than 0.25 mm FWHM. Alpha particles of 5.5 MeV energy emit luminescence in water. Although the intensity of the luminescence was smaller than that in air, it was clearly observable. The luminescence of water with alpha particles would be a new method for alpha particle detection and distribution measurements in water.

  12. Detection and measurement of neutron-irradiated gemstones

    International Nuclear Information System (INIS)

    Bunnak, S.; Jerachanchai, S.; Chinudomsub, K.; Saiyut, K.

    1990-01-01

    Color enhance gemstone, neutron-irradiated topaz, was analyzed by gamma spectrometry for examining characteristic and activity. Topaz was irradiated in the wet-tube facility of the Research Reactor TRR/1 which neutron fluence is 2.52x10 17 neutron per square centimeter. After 100 days of decay, topaz was sampling to the qualitative and quantitative analysis using multichannel analyzer of Nuclear Data Model ND65 and hyper pure germanium detector. Calculation and evaluation were done by microcomputer IBM/PC 640 KB RAM. The qualitative analysis showed that the neutron-irradiated topaz has 2 major isotopes, i.e., Ta-182 and Sc-46. Quantitative activity was compared with reference standard source Eu-152 (NBS) and the results were shown in the table 1. The Health Physics Division, OAEP, inspected on 6240.9 gm of the neutron-irradiated topaz using standard release limit 2 nCi/gm (74 Bq/gm). It was found that only 423.9 gm out of the total amount were over the standard release limit

  13. Comparison of gamma, neutron and proton irradiations of multimode fibers

    International Nuclear Information System (INIS)

    Gingerich, M.E.; Dorsey, K.L.; Askins, C.G.; Friebele, E.J.

    1987-01-01

    The effects of pure gamma, pure proton, and mixed neutron-gamma irradiation fields on a set of both pure and doped silica core multimode fibers have been investigated. Only slight differences are found in the radiation response of pure and doped silica core fibers exposed to gamma or mixed neutron-gamma fields, indicating that Co-60 sources can be used to simulate the effects of the mixed field (except in the case of a pure neutron environment). Although it is noted that neither mix field nor gamma sources adequately simulate the effects of proton irradiation of doped silica core fibers, a good correspondence is found in the case of the pure silica core waveguide. 13 references

  14. Preliminary examination of induced radio activity in pepper by 10 MeV electron irradiation

    International Nuclear Information System (INIS)

    Furuta, Masakazu; Katayama, Tadashi; Ito, Norio; Mizohata, Akira; Matsunami, Tadao; Toratani, Hirokazu; Takeda, Atsuhiko

    1989-01-01

    β-ray measurement was performed on 10 MeV electron-irradiated black pepper and white pepper in order to reconfirm the wholesomeness of irradiated food and present unambiguous data to general consumers concerning about the induced radioactivity in the irradiated foods. From elemental composition of the samples and investigation of photonuclear reactions, several β-emmitters were listed up. But no radioactivity other than from natural sources was detected in the irradiated sample by β-ray counting with 2 π gass flow counter, suggesting that the induced β-emmitters in the irradiated sample was below the detection limit of its induced radioactivity. (author)

  15. Stability of vitamin E content of {gamma}-irradiated biscuits

    Energy Technology Data Exchange (ETDEWEB)

    Taipina, Magda S.; Mastro, Nelida L. del [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: nlmastro@ipen.br; magtaipina@ig.com.br; Lamardo, Leda C.A. [Instituto Adolfo Lutz, Sao Paulo, SP (Brazil). Secao de Quimica Biologica]. E-mail: llamardo@ial.sp.gov.br

    2007-07-01

    The technology of food irradiation is seen by the industry as a means of ensuring food safety, since it exposes foods to ionizing radiation that kills insects, moulds and bacteria. The need to eliminate bacterial pathogens from read-to-eat food products must always be balanced with the maintenance of product quality. In addition to determining the effective ionizing radiation doses required for pathogen elimination the effects of irradiation on product chemistry, nutritional value and quality must also been determined. Vitamin E ({alpha}-tocopherol) is one of the most potent natural lipophilic antioxidants commonly present in the human diet. As it is considered a free radical scavenger there is a growing concern that irradiation might reduce the vitamin E content of food products prepared with ingredients rich in any of the dietary source of the vitamin. This work describes the effects of ionizing radiation on the vitamin E content of some biscuits commercially found in the market. Three lots of biscuits were used. Irradiation was performed in a {sup 60}Co Gammacell 220 source, dose rate of about 3.5 kGy/h at doses of 1 kGy and 3 kGy. For vitamin E determination samples were saponified with ethanolic potassium hydroxide in the presence of pyrogallol, and the tocopherols were extracted with petroleum ether. The absorbance was measured at 520 nm. From the obtained results it is possible to conclude that there was a notorious stability of the vitamin content of the biscuits submitted to gamma-irradiation at the assayed doses. (author)

  16. Stability of vitamin E content of γ-irradiated biscuits

    International Nuclear Information System (INIS)

    Taipina, Magda S.; Mastro, Nelida L. del; Lamardo, Leda C.A.

    2007-01-01

    The technology of food irradiation is seen by the industry as a means of ensuring food safety, since it exposes foods to ionizing radiation that kills insects, moulds and bacteria. The need to eliminate bacterial pathogens from read-to-eat food products must always be balanced with the maintenance of product quality. In addition to determining the effective ionizing radiation doses required for pathogen elimination the effects of irradiation on product chemistry, nutritional value and quality must also been determined. Vitamin E (α-tocopherol) is one of the most potent natural lipophilic antioxidants commonly present in the human diet. As it is considered a free radical scavenger there is a growing concern that irradiation might reduce the vitamin E content of food products prepared with ingredients rich in any of the dietary source of the vitamin. This work describes the effects of ionizing radiation on the vitamin E content of some biscuits commercially found in the market. Three lots of biscuits were used. Irradiation was performed in a 60 Co Gammacell 220 source, dose rate of about 3.5 kGy/h at doses of 1 kGy and 3 kGy. For vitamin E determination samples were saponified with ethanolic potassium hydroxide in the presence of pyrogallol, and the tocopherols were extracted with petroleum ether. The absorbance was measured at 520 nm. From the obtained results it is possible to conclude that there was a notorious stability of the vitamin content of the biscuits submitted to gamma-irradiation at the assayed doses. (author)

  17. An Economic Analysis of Electron Accelerators and Cobalt-60 for Irradiating Food

    OpenAIRE

    Morrison, Rosanna Mentzer

    1989-01-01

    Average costs per pound of irradiating food are similar for the electron accelerator and cobalt-60 irradiators analyzed in this study, but initial investment costs can vary by $1 million. Irradiation costs range from 0.5 to 7 cents per pound and decrease as annual volumes treated increase. Cobalt-60 is less expensive than electron beams for annual volumes below 50 million pounds. For radiation source requirements above the equivalent of 1 million curies of cobalt-60, electron beams are more e...

  18. FORMATION OF S-BEARING SPECIES BY VUV/EUV IRRADIATION OF H{sub 2}S-CONTAINING ICE MIXTURES: PHOTON ENERGY AND CARBON SOURCE EFFECTS

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.-J.; Juang, K.-J.; Qiu, J.-M.; Chu, C.-C.; Yih, T.-S. [Department of Physics, National Central University, Jhongli City, Taoyuan County 32054, Taiwan (China); Nuevo, M. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Jiménez-Escobar, A.; Muñoz Caro, G. M. [Centro de Astrobiología, INTA-CSIC, Torrejón de Ardoz, E-28850 Madrid (Spain); Wu, C.-Y. R. [Space Sciences Center and Department of Physics and Astronomy, University of Southern California, Los Angeles, CA 90089-1341 (United States); Fung, H.-S. [National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan (China); Ip, W.-H. [Graduate Institute of Astronomy, National Central University, Jhongli City, Taoyuan County 32049, Taiwan (China)

    2015-01-10

    Carbonyl sulfide (OCS) is a key molecule in astrobiology that acts as a catalyst in peptide synthesis by coupling amino acids. Experimental studies suggest that hydrogen sulfide (H{sub 2}S), a precursor of OCS, could be present in astrophysical environments. In the present study, we used a microwave-discharge hydrogen-flow lamp, simulating the interstellar UV field, and a monochromatic synchrotron light beam to irradiate CO:H{sub 2}S and CO{sub 2}:H{sub 2}S ice mixtures at 14 K with vacuum ultraviolet (VUV) or extreme ultraviolet (EUV) photons in order to study the effect of the photon energy and carbon source on the formation mechanisms and production yields of S-containing products (CS{sub 2}, OCS, SO{sub 2}, etc.). Results show that (1) the photo-induced OCS production efficiency in CO:H{sub 2}S ice mixtures is higher than that of CO{sub 2}:H{sub 2}S ice mixtures; (2) a lower concentration of H{sub 2}S enhances the production efficiency of OCS in both ice mixtures; and (3) the formation pathways of CS{sub 2} differ significantly upon VUV and EUV irradiations. Furthermore, CS{sub 2} was produced only after VUV photoprocessing of CO:H{sub 2}S ices, while the VUV-induced production of SO{sub 2} occurred only in CO{sub 2}:H{sub 2}S ice mixtures. More generally, the production yields of OCS, H{sub 2}S{sub 2}, and CS{sub 2} were studied as a function of the irradiation photon energy. Heavy S-bearing compounds were also observed using mass spectrometry during the warm-up of VUV/EUV-irradiated CO:H{sub 2}S ice mixtures. The presence of S-polymers in dust grains may account for the missing sulfur in dense clouds and circumstellar environments.

  19. Irradiation effects in beryllium exposed to high energy protons of the NuMI neutrino source

    Energy Technology Data Exchange (ETDEWEB)

    Kuksenko, V., E-mail: viacheslav.kuksenko@materials.ox.ac.uk [University of Oxford, Oxford (United Kingdom); Ammigan, K.; Hartsell, B. [Fermi National Accelerator Laboratory, Batavia (United States); Densham, C. [Rutherford Appleton Laboratory, Didcot (United Kingdom); Hurh, P. [Fermi National Accelerator Laboratory, Batavia (United States); Roberts, S. [University of Oxford, Oxford (United Kingdom)

    2017-07-15

    A beryllium primary vacuum-to-air beam ‘window’ of the 'Neutrinos at the Main Injector' (NuMI) beamline at Fermi National Accelerator Laboratory (Fermilab), Batavia, Illinois, USA, has been irradiated by 120 GeV protons over 7 years, with a maximum integrated fluence at the window centre of 2.06 10{sup 22} p/cm{sup 2} corresponding to a radiation damage level of 0.48 dpa. The proton beam is pulsed at 0.5 Hz leading to an instantaneous temperature rise of 40 °C per pulse. The window is cooled by natural convection and is estimated to operate at an average of around 50 °C. The microstructure of this irradiated material was investigated by SEM/EBSD and Atom Probe Tomography, and compared to that of unirradiated regions of the beam window and that of stock material of the same PF-60 grade. Microstructural investigations revealed a highly inhomogeneous distribution of impurity elements in both unirradiated and irradiated conditions. Impurities were mainly localised in precipitates, and as segregations at grain boundary and dislocation lines. Low levels of Fe, Cu, Ni, C and O were also found to be homogeneously distributed in the beryllium matrix. In the irradiated materials, up to 440 appm of Li, derived from transmutation of beryllium was homogeneously distributed in solution in the beryllium matrix.

  20. Evaluation of temperature history of a spherical nanosystem irradiated with various short-pulse laser sources

    Science.gov (United States)

    Lahiri, Arnab; Mondal, Pranab K.

    2018-04-01

    Spatiotemporal thermal response and characteristics of net entropy production rate of a gold nanosphere (radius: 50-200 nm), subjected to a short-pulse, femtosecond laser is reported. In order to correctly illustrate the temperature history of laser-metal interaction(s) at picoseconds transient with a comprehensive single temperature definition in macroscale and to further understand how the thermophysical response of the single-phase lag (SPL) and dual-phase lag (DPL) frameworks (with various lag-ratios') differs, governing energy equations derived from these benchmark non-Fourier frameworks are numerically solved and thermodynamic assessment under both the classical irreversible thermodynamics (CIT) as well as extended irreversible thermodynamics (EIT) frameworks is subsequently carried out. Under the frameworks of SPL and DPL with small lag ratio, thermophysical anomalies such as temperature overshooting characterized by adverse temperature gradient is observed to violate the local thermodynamic equilibrium (LTE) hypothesis. The EIT framework, however, justifies the compatibility of overshooting of temperature with the second law of thermodynamics under a nonequilibrium paradigm. The DPL framework with higher lag ratio was however observed to remain free from temperature overshooting and finds suitable consistency with LTE hypothesis. In order to solve the dimensional non-Fourier governing energy equation with volumetric laser-irradiation source term(s), the lattice Boltzmann method (LBM) is extended and a three-time level, fully implicit, second order accurate finite difference method (FDM) is illustrated. For all situations under observation, the LBM scheme is featured to be computationally superior to remaining FDM schemes. With detailed prediction of maximum temperature rise and the corresponding peaking time by all the numerical schemes, effects of the change of radius of the gold nanosphere, the magnitude of fluence of laser, and laser irradiation with

  1. Dosimetry characterization of the Tunisian Cobalt-60 gamma irradiation pilot plant for the irradiation of the mediterranean fruit fly

    International Nuclear Information System (INIS)

    Bettaieb, Nasreddine; Farah, Kaled; Kadri, Omrane; Jerbi, Taieb; Gharbi, Foued; Manai, Kais

    2005-01-01

    Cobalt-60 gamma irradiation pilot plant has been put into operation in 1999 at the National Center for nuclear scinces and technologies, Sidi-Thabet, Tunisia. An initial characterization of this pilot was performed to determine the overall performance of the irradiator in delivering absorbed dose to a product prior to routine processing, in particular sterilisation of medical devices and food irradiation. A new irradiation holder was recently installed; it was designed especially for the irradiation of pupae of the Meditterranean fruit fly. It consists of four turn plates which makes it possible to rotate the canisters holding the pupae within the radiation field. The axis of ratation is vertical and parallel to the source pencils. Prior to routine irradiation using the new irradiation holder, validation procedures are necessary to establish conditions of the irradiation within the specification. In the course of these procedures, detailed dose mapping on a vertical plane in the middel of the canister of insect pupae with bulk density of 0.446 g /cm3 was carried out for two irradiation configurations : fixed plates and turned plates. GafChromic dosimeter calibrated against Alanine / ESR dosimetry system was used for the dose measurements. The maximum and minimum dose locations were determined and the dose uniformity ratio calculated and discussed. Detailed analyses of the isodose curves and histogram of the frequency distribution of absorbed dose were also given. Transit dose and dose rate in the reference position inside the canister were measured using Fricke dosimeters. The results of measurements of absorbed dose and dose distribution in insect pupae do not show any significant difference in the dose uniformity ratio (U=Dmax / Dmin) between the two irradiation configurations. At the same time we observed with turned plates configuration an improvement of the homogeneity of the absorbed dose distribution in the insect pupae showed by the increasing of the pipae

  2. Irradiation creep in reactor graphites for HTR applications. [Neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Veringa, H J; Blackstone, R [Stichting Reactor Centrum Nederland, Petten

    1976-01-01

    A series of restrained shrinkage experiments on a number of graphites in the temperature range 400 to 1400/sup 0/C is described. A description is given of the experimental method and method of data evaluation. The results are compared with data from other sources. Analysis of data confirms that the creep coefficient, which is defined as the radiation induced creep strain per unit stress per unit neutron fluence, is inversely proportional to the pre-irradiation value of the Young's modulus of the material. The radiation creep coefficient increases with temperature in the range 400 to 1400/sup 0/C. It can be represented by the sum of two temperature dependent functions, one of which is inversely proportional to the neutron flux density, the other independent of the neutron flux density. When the data are analysed in this way it is found that the graphites investigated in the present work, although made from widely different starting materials and by different processes, show the same dependence of the irradiation creep coefficient on the temperature and the neutron flux density.

  3. Irradiation of an Accretion Disc by a Jet: General Properties and Implications for Spin Measurements of Black Holes

    Science.gov (United States)

    T.Dauser; Garcia, J.; Wilms, J.; Boeck, M.; Brenneman, L. W.; Falanga, M.; Fukumura, Keigo; Reynolds, C. S.

    2013-01-01

    X-ray irradiation of the accretion disc leads to strong reflection features, which are then broadened and distorted by relativistic effects. We present a detailed, general relativistic approach to model this irradiation for different geometries of the primary X-ray source. These geometries include the standard point source on the rotational axis as well as more jet-like sources, which are radially elongated and accelerating. Incorporating this code in the RELLINE model for relativistic line emission, the line shape for any configuration can be predicted. We study how different irradiation geometries affect the determination of the spin of the black hole. Broad emission lines are produced only for compact irradiating sources situated close to the black hole. This is the only case where the black hole spin can be unambiguously determined. In all other cases the line shape is narrower, which could either be explained by a low spin or an elongated source. We conclude that for those cases and independent of the quality of the data, no unique solution for the spin exists and therefore only a lower limit of the spin value can be given

  4. Evaluation of Ion Irradiation Behavior of ODS Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Sung; Kim, Min Chul; Hong, Jun Hwa; Han, Chang Hee; Chang, Young Mun; Bae, Chang Soo; Bae, Yoon Young; Chang, Moon Hee

    2006-08-15

    FM steel (Grade 92) and ODS alloy(MA956) specimens were ion irradiated with 122 MeV Ne ions. Irradiation temperatures were about 450 and 550 .deg. C and the peak dose was 1, 5, and 10 dpa. Cross-sectional TEM samples were prepared by the electrolytic Ni-plating after pre-treatment of the irradiated specimens. Irradiation cavities in FM steel and ODS alloy specimens were not much different in size; about 20 nm in diameter in both specimens irradiated at around 450 .deg. C. However, the size distribution of cavities in FM steel specimens was broader than that in ODS alloy specimen, indicating that the cavity growth probably via coalescence). It was noticeable that the location and the preferential growth of the cavities in FM steel specimens: cavities on the PAGB (prior austenite grain boundary) was significantly larger than those within the grains. This could be an important issue for the mechanical properties, especially high temperature creep, fracture toughness, and so on. The dependency of the dose threshold and swelling on the ratio of the inert gas concentration/dpa was analysed for the various irradiation source, including He, Ne, Fe/He, and fast neutron, and the empirical correlation was established.

  5. Evaluation of Ion Irradiation Behavior of ODS Alloys

    International Nuclear Information System (INIS)

    Jang, Jin Sung; Kim, Min Chul; Hong, Jun Hwa; Han, Chang Hee; Chang, Young Mun; Bae, Chang Soo; Bae, Yoon Young; Chang, Moon Hee

    2006-08-01

    FM steel (Grade 92) and ODS alloy(MA956) specimens were ion irradiated with 122 MeV Ne ions. Irradiation temperatures were about 450 and 550 .deg. C and the peak dose was 1, 5, and 10 dpa. Cross-sectional TEM samples were prepared by the electrolytic Ni-plating after pre-treatment of the irradiated specimens. Irradiation cavities in FM steel and ODS alloy specimens were not much different in size; about 20 nm in diameter in both specimens irradiated at around 450 .deg. C. However, the size distribution of cavities in FM steel specimens was broader than that in ODS alloy specimen, indicating that the cavity growth probably via coalescence). It was noticeable that the location and the preferential growth of the cavities in FM steel specimens: cavities on the PAGB (prior austenite grain boundary) was significantly larger than those within the grains. This could be an important issue for the mechanical properties, especially high temperature creep, fracture toughness, and so on. The dependency of the dose threshold and swelling on the ratio of the inert gas concentration/dpa was analysed for the various irradiation source, including He, Ne, Fe/He, and fast neutron, and the empirical correlation was established

  6. Reducing risk and accelerating delivery of a neutron source for fusion materials research

    Energy Technology Data Exchange (ETDEWEB)

    Surrey, E., E-mail: Elizabeth.Surrey@ccfe.ac.uk [EURATOM/CCFE, Abingdon OX14 3DB (United Kingdom); Porton, M. [EURATOM/CCFE, Abingdon OX14 3DB (United Kingdom); Davenne, T.; Findlay, D.; Letchford, A.; Thomason, J. [STFC Rutherford Appleton Laboratory, Harwell OX11 0QX (United Kingdom); Roberts, S.G.; Marrow, J.; Seryi, A. [University of Oxford, Oxford OX1 3DP (United Kingdom); Connolly, B. [University of Birmingham, Edgbaston B15 2TT (United Kingdom); Owen, H. [University of Manchester, Manchester M13 9PL (United Kingdom)

    2014-04-15

    Highlights: • Proposed neutron source for fusion materials – FAFNIR – n(d,C) stripping source. • Near term technology, reduces risk compared with IFMIF, timely data production. • Technical, economic and programme needs assessed, compatible with EU Roadmap proposals. • Safety case impacts regulatory role for source, now mainly stakeholder insurance. - Abstract: The materials engineering database relevant to fusion irradiation is poorly populated and it has long been recognized that a fusion spectrum neutron source will be required, the facility IFMIF being the present proposal. Re-evaluation of the regulatory approach for the EU proposed DEMO device shows that the purpose of the source can be changed from lifetime equivalent irradiation exposure to data generation at lower levels of exposure by adopting a defence in depth strategy and regular component surveillance. This reduces the specification of the source with respect to IFMIF allowing lower risk technology solutions to be considered. A description of such a source, the Facility for Fusion Neutron Irradiation Research, FAFNIR, is presented here along with project timescales and costs.

  7. Application of AmBe source neutron irradiator for determination of inorganic elements in commercial fertilizers

    International Nuclear Information System (INIS)

    Madi Filho, Tufic; Armelim, Maria Jose Aguirre; Fulas, Paulo Marcelo Marangon; Trevizam, Anderson Ricardo; Figueira, Rubens Cesar Lopes

    2005-01-01

    The rational use of fertilizers , for the soil fertility correction, contributes to the increase of agricultural production, using the same areas previously available. The quality of products could ne improved with reduced costs. Therefore, knowledge of the chemical characteristics of the correctives used is required to streamline the application and avoid excesses or deficiencies. The studied characteristics are generally limited to the essential nutrients for the nutrition of plants and animals, e.g.: Mn, Zn, P, K, Cu and those known toxic, such as: As, Cd, Hg and Pb. Neutron activation analysis (NAA) is a highly sensitive non destructive technique, for the determination of the elemental composition in samples. It has been particularly useful in the simultaneous determination of inorganic elements in complex samples of several kinds. Several analysis methods for activation are used, such as: comparative and absolute. Commercial fertilizers were analyzed applying the absolute and comparative methods. Using the absolute method, samples were submitted to neutron flux generated by an irradiator with two Am Be sources. The obtained results were compared with those obtained by the comparative method using neutrons generated in the IEA-R1 Reactor. (author)

  8. Isotropic irradiation of detectors from point sources

    DEFF Research Database (Denmark)

    Aage, Helle Karina

    1997-01-01

    NaI(Tl) scintillator detectors have been exposed to gamma rays from 8 different point sources from different directions. Background and backscatter of gamma-rays from the surroundings have been subtracted in order to produce clean spectra. By adding spectra obtained from exposures from different ...

  9. Internal irradiation for cystic craniopharyngioma

    International Nuclear Information System (INIS)

    Kobayashi, Tatsuya; Kageyama, Naoki

    1979-01-01

    Internal irradiation with P-32 chromic phosphate and Au-198 colloid was used to treat cystic craniopharyngioma. A newly developed dosimetric formula, by which the radiation dose can be calculated simultaneously at the cyst wall and at a point far from the radioactive source and the untoward effect of irradiation on surrounding brain tissue can be eliminated, especially in cases in which the wall is thin and can be penetrated by beta emission, was used. Radioactive phosphate or gold was injected into eight craniopharyngioma cysts throught the Ommaya reservoir and a tube inserted at the first craniotomy. All cysts were effectively treated for 3 to 33 months, to eliminate fluid retention or collapse. A collapsed cyst was removed at the second craniotomy and irradiation was histologically shown to be effective. Oculomotor palsy, a side effect of irradiation, occurred 10 days after the injection of 5 mc of P-32 chromic phosphate only in a case of small cysts (5.0 ml) in the supra- and intracellular regions. The thickness of the cyst wall was less than 0.5 mm and the oculomotor nerves were thought to adhere to the wall. Not only the amount of wall dose but also the thickness of the wall and localization of the cyst are important factors in internal irradiation. Sufficient and safer doses which kill tumor cells in the wall and have no side effects, are 9,000 to 30,000 rad. Internal irradiation can be used to treat large cysts of more than 10 ml which are supposedly difficult to remove radically and or multiple cysts. It is effective not only for cystic craniopharyngioma but also for intracrania cystic tumors other than craniopharyngioma, if dosimetry is accurate. (J.P.N.)

  10. Design and dosimetry of a novel 90y beta source to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Mueck, Konrad; Schmidt, Werner; Wexberg, Paul; Goerz, Walter; Maurer, Gerald; Gottsauner-Wolf, Michael

    2000-01-01

    Purpose: Post-dilatation irradiation of the vessel wall is currently under investigation for prevention of restenosis after balloon dilatation. For the irradiation, special sources were designed for animal experiments which would give equivalent irradiation conditions and doses to the vessel wall that would later be employed for human application. Methods and Materials: For the planned irradiations, a specially designed yttrium-wire of 0.45-mm diameter coated with a thin shrink tube to prevent contamination was deployed. Several leakage tests applied before and after application proved that the irradiation source was leakproof. Dosimetry was performed by using 0.1-mm-thick thermoluminescent dosimeters (TLD-100) calibrated against a primary standard. A shielding transport and application container was designed to facilitate the handling of the source during use, while reducing exposure of the medical personnel. Results: The designed source proves to be flexible for the insertion into proximal coronary vessels, and positioning at the site of stenosis. It provides an optimum protection of the animal and requires little radiation protection efforts on behalf of the medical staff. Dosimetric calculations and measurements showed that a centering of the source inside the vessel could be achieved with a maximum deviation of 50% between maximum and average dose levels. Conclusion: A yttrium-90 beta brachytherapy source was designed which provides high flexibility within proximal coronary arteries, ensures an adequate centering inside the artery, and provides irradiation conditions to the vessel wall of the experimental animal comparable to the application inside a human artery

  11. Temporal evolution of the environmental doce remaining in a clinical irradiation bunker after the cessation of irradiation

    International Nuclear Information System (INIS)

    Ruiz Egea, E.; Sanchez Carrascal, M.; Torres Pozas, S.; Monja Ray, P. de la; Perez Molina, J. L.; Madan Rodriguez, C.; Luque Japon, L.; Morera Molina, A.; Hernandez Perez, A.; Barquero Bravo, Y.; Morengo Pedagna, I.; Oliva Gordillo, M. C.; Martin Olivar, R.

    2011-01-01

    In this paper we try to quantify tite doce emitted by different radioactive processes that occur in the head of a clinica. Linear accelerator and the patient is irradiated, or wallc of the bunker, converted into tertiary sources of radiation trying to ectablish tite origin of the came in different parts of the bunker.

  12. DOSKMF2, Dose Rate Distribution in Co60 Gamma Irradiation Plants

    International Nuclear Information System (INIS)

    Remer, M.

    1988-01-01

    1 - Description of program or function: The DOSKMF2 code calculates dose rate distributions in gamma irradiation facilities with 60 Co sources. It has been developed as a tool for the evaluation of research units for the characterization, modification and optimization as well as for the simulation, planning design and evaluation of pilot and industrial facilities. 2 - Method of solution: The basic model of DOSKMF2 contains the computation of the exposure rate, which is dependent on a system of radiation sources (line and/or point sources) at one point of the radiation field. The geometric conditions are described by two coordinate systems. The first is used to arrange the radiation sources and tubes; the second is used to describe the shielding layers in the form of concentric circles. The build-up factor is approximated by Taylor coefficients, also in the case of multi-layer configurations. Calculations of radiation fields in complex irradiation facilities are made by many organizational variants based on the basic model. The interpretation of the results is supported by some statistical calculations. It is possible to store the calculated dose rate values for further processing. 3 - Restrictions on the complexity of the problem: The DOSKMF2 code is presently limited to 40 irradiation tubes and 10 crossed shielding layers. This can be increased by changing dimension statements and input organization

  13. Electron beam irradiation: novel technology for phytosanitary purposes

    International Nuclear Information System (INIS)

    Bhalla, Shashi; Srinivasan, K.; Dwivedi, J.; Gautam, S.; Sharma, Arun

    2015-01-01

    In the WTO regime, flow of agricultural commodities has increased, posing risk of inadvertent introduction of exotic pests. This can be minimized by undertaking quarantine measures. Quarantine/phytosanitary disinfestation treatments demand a very high level of security as the pest tolerance in quarantine is zero. Methyl bromide, a potent fumigant has been restricted in its use due to ozone depleting effect. Also, the conventional chemicals/fumigants being used world over are being restricted globally because of the various associated problems. Therefore, there is a need for an alternative ecofriendly strategy for controlling the pests. Irradiation, an approved technology by International Plant Protection Convention, appears to be a viable, nonchemical, residue-free strategy. Disinfestation of pulses with low energy electron irradiation potentially will have less deleterious effects on commodity quality than irradiation with other sources. Internationally, new radiation generating sources as Electron beam (EB) are being explored to meet import standards of quality and quarantine. The EB has a machine source and can be simply switched on or off. Irradiation of legume seeds viz., blackgram, greengram and soybean infested with pulse beetles (Callosobruchus maculatus and C. chinensis) at different doses at an energy level of 500 keV using the Accelerator facility at Raja Ramanna Centre for Advanced Technology, Indore revealed the dose-dependent effects on the insect growth parameters. Adult emergence from seeds infested with different stages was negligible and eggs laid by beetles that survived treatment did not develop into adults at higher doses. The lower doses viz., 170, 340 and 510 Gy on the other hand caused sterility effect on the insect but showed stimulatory effect on the physiological seed parameters . viz., seedling vigour and vigour index. Electron beam irradiation has a great potential for use in the disinfestation for phytosanitary purposes. Nevertheless

  14. Whey powder sterilization by ionizing irradiation

    International Nuclear Information System (INIS)

    Todorovic, M.; Salatic, Z.; Markov, S.

    1988-01-01

    Whey powder was sterilized by gamma waves application. As a source of irridiation isotope 60Co was used in Institute of Nuclear sciences B oris Kidrich , Vincha-Belgrade (Yugoslavia). The applied doses were: a, b, c, d, and e Kgy. The dose d was radappertization. After whey powder irradiation no adverse changes of organoleptic properties were noticed

  15. Skin carcinogenesis following uniform and non-uniform β irradiation

    International Nuclear Information System (INIS)

    Charles, M.W.; Williams, J.P.; Coggle, J.E.

    1989-01-01

    Where workers or the general public may be exposed to ionising radiation, the irradiation is rarely uniform. The risk figures and dose limits recommended by the International Commission on Radiological Protection (ICRP) are based largely on clinical and epidemiological studies of reasonably uniform irradiated organs. The paucity of clinical or experimental data for highly non-uniform exposures has prevented the ICRP from providing adequate recommendations. This weakness has led on a number of occasions to the postulate that highly non-uniform exposures of organs could be 100,000 times more carcinogenic than ICRP risk figures would predict. This so-called ''hot-particle hypothesis'' found little support among reputable radiobiologists, but could not be clearly and definitively refuted on the basis of experiment. An experiment, based on skin tumour induction in mouse skin, is described which was developed to test the hypothesis. The skin of 1200 SAS/4 male mice has been exposed to a range of uniform and non-uniform sources of the β emitter 170 Tm (E max ∼ 1 MeV). Non-uniform exposures were produced using arrays of 32 or 8 2-mm diameter sources distributed over the same 8-cm 2 area as a uniform control source. Average skin doses varied from 2-100 Gy. The results for the non-uniform sources show a 30% reduction in tumour incidence by the 32-point array at the lower mean doses compared with the response from uniform sources. The eight-point array showed an order-of-magnitude reduction in tumour incidence compared to uniform irradiation at low doses. These results, in direct contradiction to the ''hot particle hypothesis'', indicate that non-uniform exposures produce significantly fewer tumours than uniform exposures. (author)

  16. Identification of irradiated refrigerated pork with the DNA comet assay

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, M.M. E-mail: villavic@net.ipen.br; Marin-Huachaca, N.S.; Mancini-Filho, J. E-mail: jmancini@usp.br; Delincee, H.; Villavicencio, A.L.C.H. E-mail: henry.delincee@bfe.uni-karlsruhe.de

    2004-10-01

    Food irradiation can contribute to a safer and more plentiful food supply by inactivating pathogens, eradicating pests and by extending shelf-life. Particularly in the case of pork meat, this process could be a useful way to inactivate harmful parasites such as Trichinella and Taenia solium. Ionizing radiation causes damage to the DNA of the cells (e.g. strand breaks), which can be used to detect irradiated food. Microelectrophoresis of single cells ('Comet Assay') is a simple and rapid test for DNA damage and can be used over a wide dose range and for a variety of products. Refrigerated pork meat was irradiated with a {sup 60}Co source, Gammacell 220 (A.E.C.L.) installed in IPEN (Sao Paulo, Brazil). The doses given were 0, 1.5, 3.0 and 4.5 kGy for refrigerated samples. Immediately after irradiation the samples were returned to the refrigerator (6 deg. C). Samples were kept in the refrigerator after irradiation. Pork meat was analyzed 1, 8 and 10 days after irradiation using the DNA 'Comet Assay'. This method showed to be an inexpensive and rapid technique for qualitative detection of irradiation treatment.

  17. Identification of irradiated refrigerated pork with the DNA comet assay

    Science.gov (United States)

    Araújo, M. M.; Marin-Huachaca, N. S.; Mancini-Filho, J.; Delincée, H.; Villavicencio, A. L. C. H.

    2004-09-01

    Food irradiation can contribute to a safer and more plentiful food supply by inactivating pathogens, eradicating pests and by extending shelf-life. Particularly in the case of pork meat, this process could be a useful way to inactivate harmful parasites such as Trichinella and Taenia solium. Ionizing radiation causes damage to the DNA of the cells (e.g. strand breaks), which can be used to detect irradiated food. Microelectrophoresis of single cells (``Comet Assay'') is a simple and rapid test for DNA damage and can be used over a wide dose range and for a variety of products. Refrigerated pork meat was irradiated with a 60Co source, Gammacell 220 (A.E.C.L.) installed in IPEN (Sa~o Paulo, Brazil). The doses given were 0, 1.5, 3.0 and 4.5kGy for refrigerated samples. Immediately after irradiation the samples were returned to the refrigerator (6°C). Samples were kept in the refrigerator after irradiation. Pork meat was analyzed 1, 8 and 10 days after irradiation using the DNA ``Comet Assay''. This method showed to be an inexpensive and rapid technique for qualitative detection of irradiation treatment.

  18. Preliminary study of the preparation of uranium 232 by irradiation of protactinium 231; Etude preliminaire a la preparation d'uranium 232 par irradiation de protactinium 231

    Energy Technology Data Exchange (ETDEWEB)

    Guillot, Ph. [Commissariat a l' Energie Atomique, Fontenay aux Roses (France). Centre d' Etudes Nucleaires

    1965-07-01

    A bibliography about preparation of uranium 232 is done. This even-even isotope of uranium is suitable for radioactive tracer, neutron source through {alpha},n reaction and heat source applications. The irradiation of protactinium 231, the chemical separation and the purification of uranium are studied. (author) [French] Une etude bibliographique de la preparation d'uranium 232 a ete effectuee. Cet isotope pair-pair de l'uranium peut etre utilise en tant que traceur, source d'energie et source de neutrons, lorsqu'il est melange a un element leger tel le beryllium. Une etude du taux de formation des isotopes produits, lors de l'irradiation du protactinium 231 - une des manieres d'obtenir l'uranium 232 - a ete faite a l'aide d'un programme passe sur ordinateur. Les problemes poses par la separation chimique et la purification de l'uranium ont ete egalement envisages dans ce rapport. (auteur)

  19. Production, Distribution, and Applications of Californium-252 Neutron Sources

    International Nuclear Information System (INIS)

    Balo, P.A.; Knauer, J.B.; Martin, R.C.

    1999-01-01

    The radioisotope 252 Cf is routinely encapsulated into compact, portable, intense neutron sources with a 2.6-year half-life. A source the size of a person's little finger can emit up to 10 11 neutrons/s. Californium-252 is used commercially as a reliable, cost-effective neutron source for prompt gamma neutron activation analysis (PGNAA) of coal, cement, and minerals, as well as for detection and identification of explosives, laud mines, and unexploded military ordnance. Other uses are neutron radiography, nuclear waste assays, reactor start-up sources, calibration standards, and cancer therapy. The inherent safety of source encapsulations is demonstrated by 30 years of experience and by U.S. Bureau of Mines tests of source survivability during explosions. The production and distribution center for the U. S Department of Energy (DOE) Californium Program is the Radiochemical Engineering Development Center (REDC) at Oak Ridge National Laboratory (ORNL). DOE sells 252 Cf to commercial reencapsulators domestically and internationally. Sealed 252 Cf sources are also available for loan to agencies and subcontractors of the U.S. government and to universities for educational, research, and medical applications. The REDC has established the Californium User Facility (CUF) for Neutron Science to make its large inventory of 252 Cf sources available to researchers for irradiations inside uncontaminated hot cells. Experiments at the CUF include a land mine detection system, neutron damage testing of solid-state detectors, irradiation of human cancer cells for boron neutron capture therapy experiments, and irradiation of rice to induce genetic mutations

  20. Microstructure and damage behavior of W-Cr alloy under He irradiation

    Science.gov (United States)

    Huang, Ke; Luo, Lai-Ma; Zan, Xiang; Xu, Qiu; Liu, Dong-Guang; Zhu, Xiao-Yong; Cheng, Ji-Gui; Wu, Yu-Cheng

    2018-04-01

    In this study, a large-power inductively coupled plasma source was designed to perform the continuous helium ion irradiations of W-Cr binary alloy (W-20 wt%Cr) under relevant conditions of the International Thermonuclear Experimental Reactor. Surface damages and microstructures of irradiated W-20Cr were observed by using scanning electron microscopy, energy-dispersive X-ray spectroscopy, and transmission electron microscopy. The addition of Cr dramatically enhanced the micro-hardness of the obtained bulk materials, and the interface between the W matrix and the second phase Cr-O is a semi-coherent interface. After irradiation, the doping of Cr element effectively reduces the damage of the W matrix during the irradiation process. The semi-coherent interface between the second phase and the W matrix improves the anti-irradiation performance of the W-20Cr alloy.

  1. Dismantling and disposal of the Chisobox experimental irradiator

    International Nuclear Information System (INIS)

    Kriz, R.

    2005-01-01

    The Chisobox experimental irradiator was installed at the Faculty of Medicine in Hradec Kralove, Radioisotope Laboratories and Vivarium, for the purposes of the scientific research of ionizing radiation effects on the living organisms. The irradiator was put into operation in 1977. After 1989, its use has been - significantly reduced and it was only employed for the sterilization of medical materials and aids as well as for the radiation treatment of antique and museum things having wood-worm. In January 2001, its next operation was determined by the SUJB decision (i.e. The State Office for Nuclear Safety) in which the constancy tests for all individual ionizing radiation sources being part of the system were required. As the f constancy tests were not performed at that time, the Faculty Management decided for the -- decommissioning of the irradiator in June 2001. In 2003, the Faculty of Medicine announced a tender for the category III workplace disposal. Primarily, the VF, a.s. in cooperation with the SURAO Prague (i.e. the Radioactive Waste Repository Authority) were to have disposed this workplace, and a hot cell designed to be built in Litomerice by the SURAO was to have been used for this project. However, the Faculty of Medicine got a grant for the irradiator disposal in 2004 providing that the disposal had to be finished in the same year. For this reason, the complete project has been assigned to the VF, a.s. Company, which put its hot cell into operation in 2004. The VF, a.s. Company finished the disposal of the irradiator in October/November 2004. After the agreement with the SURAO in April 2005, the sealed sources placed in the storage baskets were put into a newly manufactured container -a non-standard storage unit -and transported to be stored in the URAO Richard in Litomerice. (authors)

  2. The theoretical basis and clinical methodology for stereotactic interstitial brain tumor irradiation using iododeoxyuridine as a radiation sensitizer and samarium-145 as a brachytherapy source

    International Nuclear Information System (INIS)

    Goodman, J.H.; Gahbauer, R.A.; Kanellitsas, C.; Clendenon, N.R.; Laster, B.H.; Fairchild, R.G.

    1989-01-01

    High grade astrocytomas have proven resistant to all conventional therapy. A technique to produce radiation enhancement during interstitial brain tumor irradiation by using a radiation sensitizer (IdUrd) and by stimulation of Auger electron cascades through absorption of low energy photons in iodine (Photon activation) is described. Clinical studies using IdUrd, 192 Ir as a brachytherapy source, and external radiation have produced promising results. Substituting samarium-145 for 192 Ir in this protocol is expected to produce enhanced results. 15 refs

  3. Basic Design Study on 1-MV Electrostatic Accelerator for ion irradiation

    International Nuclear Information System (INIS)

    Cho, Yongsub; Kim, Kyeryung; Lee, Chanyoung

    2014-01-01

    The KOMAC (KOrea Multi-purpose Accelerator Complex) has electrostatic ion accelerators whose terminal voltages are less than 100kV. To extend ion beam irradiations with higher energy ions for industrial purposes, an electrostatic accelerator of 1-MV terminal voltage should have been studied. For industrial applications, the most important features of the accelerator are high current and high reliability for high irradiation dose and high through-put with high current and long irradiation time. The basic study on 1-MV electrostatic ion accelerator for industrial applications has been done. The key components are a high voltage power supply, an ion source, and an accelerating column. The feasibility study for fabrication is being performed. Especially the R and D for ion source is required. The 1-MV ion accelerator will be constructed with domestic companies and installed in the beam application research building, which is under construction in the site of KOMAC at Gyeongju

  4. Food irradiation and habitual consumption of food

    International Nuclear Information System (INIS)

    Omi, Nelson M.

    2005-01-01

    In the last years, an increasing amount of people is consuming more fruits, vegetables, seeds and sprouts, with the health effects of food in mind. Otherwise, the accepted shelf food safety found in some countries led to a growing trust in the product's hygienic quality, that leads to behaviors like opening a package and immediately consume the contents. Besides the well disseminated knowledge of good cooking practices, the lack of time, found mainly in big cities, may take to the dinning tables food with an increasing potential of pathogenic organisms contamination. For instance, the alfalfa, beam, clover and radish sprouts caused many reported Salmonella and E. coli outbreaks in countries like the USA, United Kingdom, Japan, Sweden, Finland, Canada and Denmark. Many of the likely source of contaminations were the contamination of the seeds before sprouting. To control these contaminations, the irradiation doses over 1 kGy is effective and the association of irradiation and chemical treatments is being studied. The bacteriological control performance of the irradiation becomes this technique one of the most applied to dry herbs and spices witch, without adequate treatment, could be important sources of foodborne outbreaks. Good production, handling, packing and distribution practices may, with the use of ionizing radiation to reach the desired bacteriological inactivation or decontamination level, significantly contribute to the necessary food safety, allowing it to be safely ready to eat. (author)

  5. Irradiation probe and laboratory for irradiated material evaluation

    International Nuclear Information System (INIS)

    Smutny, S.; Kupca, L.; Beno, P.; Stubna, M.; Mrva, V.; Chmelo, P.

    1975-09-01

    The survey and assessment are given of the tasks carried out in the years 1971 to 1975 within the development of methods for structural materials irradiation and of a probe for the irradiation thereof in the A-1 reactor. The programme and implementation of laboratory tests of the irradiation probe are described. In the actual reactor irradiation, the pulse tube length between the pressure governor and the irradiation probe is approximately 20 m, the diameter is 2.2 mm. Temperature reaches 800 degC while the pressure control system operates at 20 degC. The laboratory tests (carried out at 20 degC) showed that the response time of the pressure control system to a stepwise pressure change in the irradiation probe from 0 to 22 at. is 0.5 s. Pressure changes were also studied in the irradiation probe and in the entire system resulting from temperature changes in the irradiation probe. Temperature distribution in the body of the irradiation probe heating furnace was determined. (B.S.)

  6. Texture, color, lipid oxidation and sensory acceptability of gamma-irradiated marinated anchovy fillets

    Science.gov (United States)

    Tomac, Alejandra; Cova, María C.; Narvaiz, Patricia; Yeannes, María I.

    2015-01-01

    The effect of gamma irradiation (0, 2, 3 and 4 kGy) on vacuum-packed marinated anchovy fillets was analyzed for their texture, color, lipid oxidation and sensory acceptability after 10 months under refrigeration. Marinated (3% acetic acid, 10% sodium chloride and 0.2% citric acid) Engraulis anchoita fillets were vacuum-packed and irradiated with a cobalt-60 source at a semi-industrial irradiation facility. The irradiation caused a slight increase in hardness values regardless of the applied dose but maintained a consistent texture over the 10 months, even though the control samples softened, most likely due to degradation. This hardness increase did not affect the textural sensory acceptability. Irradiation did not modify the color but still reduced color changes during storage, benefitting the product's quality. TBARS was increased in every sample throughout storage, but irradiation decreased these values. Sensory acceptability was not affected by gamma irradiation. Therefore, gamma irradiation could be successfully applied to this type of product for the purpose of shelf-life extension.

  7. Radiation sources and technical services

    International Nuclear Information System (INIS)

    Stonek, K.; Satorie, Z.; Vyskocil, I.

    1981-01-01

    Work is briefly described of the department for sealed sources production of the Institute, including leak testing and surface contamination of sealed sources. The department also provides technical services including the inspections of sealed sources used in medicine and geology and repair of damaged sources. It carries out research of the mechanical and thermal strength of sealed sources and of the possibility of reprocessing used 226 Ra sources. The despatch department is responsible for supplying the entire country with home and imported radionuclides. The department of technical services is responsible for testing imported radionuclides, assembling materials testing, industrial and medical irradiation devices, and for the collection and storage of low-level wastes on a national scale. (M.D.)

  8. Polymeric materials obtained by electron beam irradiation

    International Nuclear Information System (INIS)

    Dragusin, M.; Moraru, R.; Martin, D.; Radoiu, M.; Marghitu, S.; Oproiu, C.

    1995-01-01

    Research activities in the field of electron beam irradiation of monomer aqueous solution to produce polymeric materials used for waste waters treatment, agriculture and medicine are presented. The technologies and special features of these polymeric materials are also described. The influence of the chemical composition of the solution to ba irradiated, absorbed dose level and absorbed dose rate level are discussed. Two kinds of polyelectrolytes, PA and PV types and three kinds of hydrogels, pAAm, pAAmNa and pNaAc types, the production of which was first developed with IETI-10000 Co-60 source and then adapted to the linacs built in Accelerator Laboratory, are described. (author)

  9. A microbiological study on irradiated sludge composting

    International Nuclear Information System (INIS)

    Pongpat, S.; Hashimoto, Shoji.

    1993-03-01

    Effect of fermentation temperature on microorganisms in sewage sludge compost and suppressive effect of the compost on Fusarium oxysporum were investigated. Dehydrated sewage sludge was irradiated at 10 kGy by cobalt 60 gamma ray source and fermented at various temperatures with six different seed-composts. It was found that microorganisms showed higher growth in irradiated sludge at the temperature around 30 to 40degC. One of the seed-composts and compost produced from the seed-compost showed the remarkable effects of suppression on F. oxysporum. It can be also observed that the composts produced by lower temperature fermentation showed higher suppression. (author)

  10. An irradiation marker for mango seed weevil

    International Nuclear Information System (INIS)

    Heather, N.W.; Lescano, H.G.; Congdon, B.C.

    1999-01-01

    The objective of this study was to look for a method to determine whether live mango seed weevil, Sternochetus mangifera (Fabricius) present in fruit had been irradiated at a quarantine dose or lower. We looked specifically for anatomical effects on the supra-oesophageal ganglion of larvae and tested a biochemical method for detection of the effects of irradiation on the protein profile of pupae. Neither method was successful. However, because for most international export markets mangoes need only be found free of the pest at inspection sourcing from pest-free production orchards and quality control systems incorporating requisite pest management components could prove practicable and satisfy most markets. (author)

  11. A microbiological study on irradiated sludge composting

    Energy Technology Data Exchange (ETDEWEB)

    Pongpat, S. [Office of Atomic Energy for Peace, Bangkok (Thailand); Hashimoto, Shoji

    1993-03-01

    Effect of fermentation temperature on microorganisms in sewage sludge compost and suppressive effect of the compost on Fusarium oxysporum were investigated. Dehydrated sewage sludge was irradiated at 10 kGy by cobalt 60 gamma ray source and fermented at various temperatures with six different seed-composts. It was found that microorganisms showed higher growth in irradiated sludge at the temperature around 30 to 40degC. One of the seed-composts and compost produced from the seed-compost showed the remarkable effects of suppression on F. oxysporum. It can be also observed that the composts produced by lower temperature fermentation showed higher suppression. (author).

  12. Neutron sources and applications

    Energy Technology Data Exchange (ETDEWEB)

    Price, D.L. [ed.] [Argonne National Lab., IL (United States); Rush, J.J. [ed.] [National Inst. of Standards and Technology, Gaithersburg, MD (United States)

    1994-01-01

    Review of Neutron Sources and Applications was held at Oak Brook, Illinois, during September 8--10, 1992. This review involved some 70 national and international experts in different areas of neutron research, sources, and applications. Separate working groups were asked to (1) review the current status of advanced research reactors and spallation sources; and (2) provide an update on scientific, technological, and medical applications, including neutron scattering research in a number of disciplines, isotope production, materials irradiation, and other important uses of neutron sources such as materials analysis and fundamental neutron physics. This report summarizes the findings and conclusions of the different working groups involved in the review, and contains some of the best current expertise on neutron sources and applications.

  13. Neutron sources and applications

    International Nuclear Information System (INIS)

    Price, D.L.; Rush, J.J.

    1994-01-01

    Review of Neutron Sources and Applications was held at Oak Brook, Illinois, during September 8--10, 1992. This review involved some 70 national and international experts in different areas of neutron research, sources, and applications. Separate working groups were asked to (1) review the current status of advanced research reactors and spallation sources; and (2) provide an update on scientific, technological, and medical applications, including neutron scattering research in a number of disciplines, isotope production, materials irradiation, and other important uses of neutron sources such as materials analysis and fundamental neutron physics. This report summarizes the findings and conclusions of the different working groups involved in the review, and contains some of the best current expertise on neutron sources and applications

  14. Physico-chemical characterization of gamma rays irradiated crotamine

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Karina Corleto de; Spencer, Patrick Jack; Nascimento, Nanci do [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)], e-mail: kcorleto@usp.br

    2009-07-01

    Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. It has been employed to attenuate animal toxins. Crotamine, a toxin from Crotalus durissus terrificus (Cdt), is a highly basic polypeptide (pI - 10.3), with myotoxic activity and molecular weight of 4882 Da. It is composed of 42 amino acids residues and reticulated by three disulfide bonds. This study aimed the characterization of irradiated crotamine using Circular Dichroism (CD), Fluorescence Spectroscopy and Differential Scanning Calorimetry (DSC) techniques. We used size exclusion and ion-exchange chromatography to purify it from Cdt crude venom. The pure crotamine was irradiated with 2.0 kGy from a {sup 60}Co source. Native and irradiated crotamine were analyzed in a fluorescence spectrophotometer (Hitachi F-4500), under excitation wavelength at 275 nm and the emission was scanned from 300 to 500 nm. The analysis of fluorescence quenching showed that the irradiated form displayed a lower quantum yield when compared to the native form. CD spectra, obtained from a Jasco, J-180 spectropolarimeter, of native and irradiated crotamine solutions, showed a discrete change between the samples, from apparently ordered conformation to a random coil. Finally, the thermodynamics analysis, realized in a calorimeter METTLER TOLEDO, DSC 822e, showed that irradiation promoted changes in the calorimetric profile. Our results indicate that irradiation leads to progressive changes in the structure of the toxin, which could explain the decrease in myotoxic activity. (author)

  15. Physico-chemical characterization of gamma rays irradiated crotamine

    International Nuclear Information System (INIS)

    Oliveira, Karina Corleto de; Spencer, Patrick Jack; Nascimento, Nanci do

    2009-01-01

    Ionizing radiation can change the molecular structure and affect the biological properties of biomolecules. It has been employed to attenuate animal toxins. Crotamine, a toxin from Crotalus durissus terrificus (Cdt), is a highly basic polypeptide (pI - 10.3), with myotoxic activity and molecular weight of 4882 Da. It is composed of 42 amino acids residues and reticulated by three disulfide bonds. This study aimed the characterization of irradiated crotamine using Circular Dichroism (CD), Fluorescence Spectroscopy and Differential Scanning Calorimetry (DSC) techniques. We used size exclusion and ion-exchange chromatography to purify it from Cdt crude venom. The pure crotamine was irradiated with 2.0 kGy from a 60 Co source. Native and irradiated crotamine were analyzed in a fluorescence spectrophotometer (Hitachi F-4500), under excitation wavelength at 275 nm and the emission was scanned from 300 to 500 nm. The analysis of fluorescence quenching showed that the irradiated form displayed a lower quantum yield when compared to the native form. CD spectra, obtained from a Jasco, J-180 spectropolarimeter, of native and irradiated crotamine solutions, showed a discrete change between the samples, from apparently ordered conformation to a random coil. Finally, the thermodynamics analysis, realized in a calorimeter METTLER TOLEDO, DSC 822e, showed that irradiation promoted changes in the calorimetric profile. Our results indicate that irradiation leads to progressive changes in the structure of the toxin, which could explain the decrease in myotoxic activity. (author)

  16. The field-irradiator gamma study: Fourteen years of irradiation of the boreal forest

    International Nuclear Information System (INIS)

    Amiro, B.D.; Hawkins, J.L.; Laverock, M.J.; Sheppard, S.C.

    1996-01-01

    The Field-Irradiator Gamma (FIG) project is a long-term experiment on the response of boreal forest vegetation to chronic ionizing radiation. The forest was irradiated from 1973 to 1986 by a 370 TBq point source of 137 Cs placed at a height of 20 m. The forest is now in the recovery phase. The irradiated forest included several different community types, and each of these was affected differently by the radiation stress. New vegetation zones have now been created because of the selective tolerance to radiation along a gradient from background dose rates to a maximum of 65 mGy h -1 . One of the easiest measured indicators of the radiation stress has been photographic documentation of changes in forest communities over time. Measured changes in species composition and the decrease in tree canopy cover at dose rates >2 Gy h -1 have also helped quantify radiation effects. Indicators such as trends in annual growth rings have been less satisfactory. Our experiment suggests that there are no visible impacts at chronic dose rates less than 0.1 mGy h -1 and the threshold for effects likely is between 0.1 and 1 mGy h -1 . The experimental area has been preserved to allow measurements of long-term recovery of the site

  17. The effect of irradiation on the macro- and microstructure of strawberries

    International Nuclear Information System (INIS)

    Voeroes, Zsuzsanna; Kovacs, Etelka; Zackel, Erna

    1985-01-01

    Samples of Gorella, Pocahontas and Rival strawberry varieties were irradiated (2,5 kGy) by means of a sup(60)Co source to increase storage life. The packaged fruits were stored in cabinets of 80-90% relative vapour content at 5 and 10 deg C, respectively. No significant differences could be found in the refraction % and pH values of the irradiated and control samples and of the packeged and unpackaged samples. Due to irradiation the consistency of fruits softened. At the measurements of strawberries with Instron consistometer the optimal quality marks seem to be obtainable by measuring the deformation steadiness. By means of optical microscopy it was stated that the tissue structure of various strawberry varieties did not alter essentially due to irradiation. (author)

  18. Extending shelf-life and economic evaluation of strawberry irradiated in Egypt

    International Nuclear Information System (INIS)

    Mahmoud, A.A.

    1988-01-01

    This study was made on ''Egypt's mega gamma I'' irradiator the radiation which is cobalt-60. The following dose was studied in detail 3.5 KGy, was compared with unirradiated sample was studied at the same time. The storage conditions for refrigeration were 4+-1 0 C. During storage periodic fruits were carried out as certain organoleptic properties. The refrigerated irradiated fruits have a shelf life of more than 30 days, whereas the unirradiated ones last only up to 14 days. On the other side the study of economic evaluation of irradiated strawberry showed that the activity of cobalt-60 source needed to satisfy requirement of gamma-irradiation processing of the annual strawberry production in Egypt has been figured a 0.563 Mci for a total activity

  19. Effect of UV irradiation on the apoptosis and necrosis of Jurkat cells using UV LEDs

    Science.gov (United States)

    Inada, Shunko A.; Amano, Hiroshi; Akasaki, Isamu; Morita, Akimichi; Kobayashi, Keiko

    2009-02-01

    Phototherapy is a very effective method for treating most of the incurable skin diseases. A fluorescent light bulb is used as a conventional UV light source for this type of therapy. However, infrared radiation from the light source sometimes causes serious problems on patient's health. In addition, the normal part of the skin is irradiated when a large fluorescent light bulb is used. Moreover, a conventional UV irradiation system is heavy and has a short lifetime and a high electrical power consumption. Therefore, a new UV light source for solving the problems of phototherapy is required. To realize low-power-consumption, lightweight and long-lifetime systems, group III nitride-based UV-A1 light-emitting diodes (LEDs) were investigated. We examined the UV LED irradiation of Jurkat cell, which is a tumor cell and more sensitive to UV light than a healthy cell. The numbers of apoptotic and necrotic cells were confirmed to be the same using a UV LED and a conventional lamp system. The UV LED showed the possibility of realizing a new UV light source for phototherapy.

  20. Information channel effects on women intention to purchase irradiated food in Korea

    International Nuclear Information System (INIS)

    Byun, Myung-Woo; Oh, Sang-Hee; Kim, Jae-Hun; Yoon, Yohan; Park, Seong-Cheol; Kim, Hak-Soo; Kim, Soon-Bok; Han, Sang-Bae; Lee, Ju-Woon

    2009-01-01

    Since the first irradiated food was approved and commercialized in 1987, most of Koreans still do not accept the irradiated food until now. It is reasoned that there are the ambiguous fear of nuclear technology and the confusion between irradiated food and radioactive-contaminated food. This investigation was carried out to examine the acknowledgement of irradiated food in Korean housewives and to study how to enhance the intention of purchasing the irradiated food. About 600 Korean housewives participated in the survey on the irradiated food in 2007, more than two-thirds of them were not aware of irradiated food. One hundred and fifty-four women who had known of irradiated food were subjected to an experiment for the source of information about irradiated food (e.g., lecture by an expert, video-watching and book-reading) in order to explore which type of information channel is the most effective in eliciting purchase intention. The result showed that the women group who had heard the lecture by an expert indicated the highest intention to purchase irradiated food, followed by the video-watching and the book-reading groups. In addition, the acceptance of the irradiated food had shown to lead the support for nuclear industry.

  1. Information channel effects on women intention to purchase irradiated food in Korea

    Science.gov (United States)

    Byun, Myung-Woo; Oh, Sang-Hee; Kim, Jae-Hun; Yoon, Yohan; Park, Seong-Cheol; Kim, Hak-Soo; Kim, Soon-Bok; Han, Sang-Bae; Lee, Ju-Woon

    2009-07-01

    Since the first irradiated food was approved and commercialized in 1987, most of Koreans still do not accept the irradiated food until now. It is reasoned that there are the ambiguous fear of nuclear technology and the confusion between irradiated food and radioactive-contaminated food. This investigation was carried out to examine the acknowledgement of irradiated food in Korean housewives and to study how to enhance the intention of purchasing the irradiated food. About 600 Korean housewives participated in the survey on the irradiated food in 2007, more than two-thirds of them were not aware of irradiated food. One hundred and fifty-four women who had known of irradiated food were subjected to an experiment for the source of information about irradiated food (e.g., lecture by an expert, video-watching and book-reading) in order to explore which type of information channel is the most effective in eliciting purchase intention. The result showed that the women group who had heard the lecture by an expert indicated the highest intention to purchase irradiated food, followed by the video-watching and the book-reading groups. In addition, the acceptance of the irradiated food had shown to lead the support for nuclear industry.

  2. Dose rate distribution of the GammaBeam: 127 irradiator using MCNPX code

    International Nuclear Information System (INIS)

    Gual, Maritza Rodriguez; Batista, Adriana de Souza Medeiros; Pereira, Claubia; Faria, Luiz O. de; Grossi, Pablo Andrade

    2013-01-01

    The GammaBeam - 127 Irradiator is widely used for biological, chemical and medical applications of the gamma irradiation technology using Cobalt 60 radioactive at the Centro de Desenvolvimento da Tecnologia Nuclear CDTN/CNEN, Belo Horizonte, Brazil. The source has maximum activity of 60.000Ci, which is composed by 16 double encapsulated radioactive pencils placed in a rack. The facility is classified by the IAEA as Category II (dry storage facility). The aim of this work is to present a modelling developed to evaluate the dose rates at the irradiation room and the dose distribution at the irradiated products. In addition, the simulations could be used as a predictive tool of dose evaluation in the irradiation facility helping benchmark experiments in new similar facilities. The MCNPX simulated results were compared and validated with radiometric measurements using Fricke and TLDs dosimeters along several positions inside the irradiation room. (author)

  3. CONTRASTING DOSE-RATE EFFECTS OF GAMMA-IRRADIATION ON RAT SALIVARY-GLAND FUNCTION

    NARCIS (Netherlands)

    VISSINK, A; DOWN, JD; KONINGS, AWT

    The aim of this study was to investigate the effects of Co-60 irradiation delivered at high (HDR) and low (LDR) dose-rates on rat salivary gland function. Total-body irradiation (TBI; total doses 7.5, 10 and 12.5 Gy) was applied from a Co-60 source at dose-rates of 1 cGy/min (LDR) and 40 cGy/min

  4. Food irradiation: physical-chemical, technological and economical background and competing methods of food preservation

    International Nuclear Information System (INIS)

    Zagorski, Z.P.

    1994-01-01

    Physical, chemical and technical as well as economical background of food preservation by irradiation have been performed. The radiation sources and the elements of radiation chemistry connected with their use in food irradiation process have been shown. The problems of dosimetry and endurance of dose uniformity for processed products have been also discussed. The other methods of food preservation and their weakness and advantages have been also presented and compared with food irradiation method

  5. Effects of gamma irradiation for quality of marine products

    International Nuclear Information System (INIS)

    Yamashita, Michiaki; Ishida, Noriko

    2004-01-01

    Muscles of sardine and tuna were used as an experimental materials for research of relations between radiation dose and lipid deterioration, lipid hydroperoxide and fish protein. The experimental samples were irradiated by 60 Co source within 0.1∼2 kGy of gamma-ray doses. Methylene blue inducer was used for quantification of the lipid hydroperoxide which was generated in the irradiated samples. High sensitive and quantitative micro-analysis for the lipid hydroperoxide which were produced singularly by gamma-ray irradiation was established on marine products. The lipid hydroperoxide in marine products was generated by oxidation of unsaturated fatty acid. Reaction mechanism of the lipid hydroperoxide which modified a protein of muscle fiber in particular was estimated. (M. Suetake)

  6. Food irradiation

    International Nuclear Information System (INIS)

    Sato, Tomotaro; Aoki, Shohei

    1976-01-01

    Definition and significance of food irradiation were described. The details of its development and present state were also described. The effect of the irradiation on Irish potatoes, onions, wiener sausages, kamaboko (boiled fish-paste), and mandarin oranges was evaluated; and healthiness of food irradiation was discussed. Studies of the irradiation equipment for Irish potatoes in a large-sized container, and the silo-typed irradiation equipment for rice and wheat were mentioned. Shihoro RI center in Hokkaido which was put to practical use for the irradiation of Irish potatoes was introduced. The state of permission of food irradiation in foreign countries in 1975 was introduced. As a view of the food irradiation in the future, its utilization for the prevention of epidemics due to imported foods was mentioned. (Serizawa, K.)

  7. Food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gruenewald, T

    1985-01-01

    Food irradiation has become a matter of topical interest also in the Federal Republic of Germany following applications for exemptions concerning irradiation tests of spices. After risks to human health by irradiation doses up to a level sufficient for product pasteurization were excluded, irradiation now offers a method suitable primarily for the disinfestation of fruit and decontamination of frozen and dried food. Codex Alimentarius standards which refer also to supervision and dosimetry have been established; they should be adopted as national law. However, in the majority of cases where individual countries including EC member-countries so far permitted food irradiation, these standards were not yet used. Approved irradiation technique for industrial use is available. Several industrial food irradiation plants, partly working also on a contractual basis, are already in operation in various countries. Consumer response still is largely unknown; since irradiated food is labelled, consumption of irradiated food will be decided upon by consumers.

  8. Isolation of Enterobacter cowanii in tomatoes after gamma irradiation

    International Nuclear Information System (INIS)

    Vicalvi, M.C.V.; Solidonio, E.G.; Silva, M.A.; Colaco, W.; Silva, G.R. da; Sena, K.X.F.R de

    2013-01-01

    The tomato is one of the most consumed fruit in the world. Bacteria of the family Enterobacteriaceae are responsible for large outbreaks of gastroenteritis. Irradiation is a physical method which reduces waste by eliminating spoilage organisms in foods. The objective of this study was to identify and determine the resistance profile of micro-organisms of the family Enterobacteriaceae from irradiated tomatoes. Were used three batches each containing 80 tomatoes, and divided in control and irradiated. The samples were individually properly identified as the irradiation dose applied. The material was subjected to irradiation with gamma rays, for irradiating with a cobalt-60 source, using doses: 1.0, 1.5 and 2 kGy (6,060 kGy/h). For microbiological analysis tomatoes were cut out, and removing the shells to obtain samples weighing 25g. Each sample was transferred to an Erlenmeyer containing sterilized water, stirring the assembly mechanically. Aliquots of the wash waters were sown in differential and selective media. After reisolation, the colonies were subjected to Gram staining then performed biochemical tests for identification. The antibiotic susceptibility tests were performed according to CLSI (Clinical Laboratory Standard Institute). It was isolated three strains of Enterobacter cowanii in tomato samples irradiated with a dose of 1.0 kGy, without isolating the other doses. As for the resistance profile, the strains were resistant to Ampicillin identified. Gamma irradiation at a dose of 1.5 and 2 kGy was effective in tomatoes as well as the micro-organism isolated after irradiation showed no profile of multidrug resistance. (author)

  9. Control of sealed sources and equipments used in gammagraphy

    International Nuclear Information System (INIS)

    Sahyun, A.; Sordi, G.-M.A.A.; Biazzini Filho, F.L.

    1988-01-01

    The Radiation Protection Department of the IPEN-CNEN/SP, in 1987, formed a section incharged to control all radioactive material: a) received by the IPEN-CNEN/SP; b) produced by the IPEN-CNEN/SP; c) delivered from the IPEN-CNEN/SP. The aim of this section is to maintain a permanent control of all radioactive sources movement got at the IPEN-CNEN/SP. This control is performed with a microcomputer, trademark MICRODIGITAL, model TK3000 //e, 256 KBytes of memory, utilizing the TOTALWORKS program. This program permits to have the origin, characteristics and address of the radioactive sources, its sites in the IPEN, its uses, etc. Already we have put in the microcomputer, the control of the sealed sources produced used in nondestructive test, the inspection control of the gamagraphy irradiator and the control of the depleted sources. The next step is to introduce in the computer the inspection of the remote control of the irradiator. The aim of this paper is to describe the control program that was already put on. This radioactive material control was started with the sealed sources used in gamagraphy because we believe that is the field with the most likelihood of accident in the population, and therefore it's that need the most hard control about the site and the performance of the irradiation facility. (author) [pt

  10. Gamma irradiation of the face fly Musca autumnalis DeGeer (Diptera: Muscidae)

    International Nuclear Information System (INIS)

    Gregory, D.J.

    1974-01-01

    Pupae of the face fly were irradiated at 5 days of age using gamma radiation from a Co-60 source. Experiments were conducted to determine the effect of radiation dose on the fertility and longevity of the resulting adults. An irradiation dose of 2.5 krad induced permanent sterility in both males and females without affecting their longevity significantly. Competitive and mating tests indicated that males irradiated at 2.5 krad were as competitive as normal males. A colony of flies was infected with the nematode parasite, Heterotylenchus autumnalis Nickle. Irradiation of parasitized, 5-day-old pupae, indicated that the parasite was not adversely affected by radiation doses of 1.0 and 2.5 krad. (author)

  11. Response of Boreal forest tree canopy cover to chronic gamma irradiation

    International Nuclear Information System (INIS)

    Amiro, B.D.

    1994-01-01

    A section of the Canadian Boreal forest was irradiated chronically by a point source of 137 Cs from 1973 to 1986. Tree canopy cover was measured at permanently marked locations during the pre-irradiation, irradiation and post-irradiation phases, spanning a period of two decades. The tree canopy was severely affected at dose rates greater than 10 mGy/h delivered chronically. The canopy of sensitive coniferous tree species, such as Abies balsamea and Picea Mariana, decreased at dose rates greater than 2 mGy/h, but in some cases the tree canopy was replaced by more resistant species, such as Populus tremuloides and Salix bebbiana. Effects on canopy cover could not be detected at dose rates less than 0.1 mGy/h. Even at dose rates of 5 mGy/h, the forest canopy is recovering six years after irradiation stopped. (author)

  12. Measurements of integrated components' parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests

    International Nuclear Information System (INIS)

    Fuan, J.

    1991-01-01

    This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components's parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test [fr

  13. Transference of genetic information through irradiated pollen

    Energy Technology Data Exchange (ETDEWEB)

    Dryanovska, O A [Bylgarska Akademiya na Naukite, Sofia. Inst. po Genetika

    1983-01-01

    Blossoms are used as mothers of two longistylous with male sterility varieties of Deva and Hera without anthocyan on the stem from L. esculentum (Mill.) (L.), which were pollinated with irradiated dallenform L. peruvianum (L.) with anthocyan on the stem, with 10 AND 200 Kr of gamma-rays, 5 and 10 min from a source of mixed (long and short) UV-rays, at a distance of 20 cm, while the control blossoms were pollinated with a mixture of other cultivated plants. Irradiation with gamma rays was carried out on a gamma device with a dose power of up to 1,500 R/m. The results show that irradiated pollen tube with the male chromatin induces gynogenesis and seconadary diploidization. It is assumed that some of the microfragments irradiated with high doses of radiation contain a functionally active gene or the genes responsible for anthocyan synthesis. These microfragments are capable of combining with the nonirradiated mother chromatin and they become involved and operate in the process of development of the mother sex cells and at the early embryogenesis, as a result of which anthocyan appears in the developing plants.

  14. Transference of genetic information through irradiated pollen

    International Nuclear Information System (INIS)

    Dryanovska, O.A.

    1983-01-01

    Blossoms are used as mothers of two longistylous with male sterility varieties of Deva and Hera without anthocyan on the stem from L. esculentum (Mill.) (L.), which were pollinated with irradiated dallenform L. peruvianum (L.) with anthocyan on the stem, with 10 AND 200 Kr of gamma-rays, 5 and 10 min from a source of mixed (long and short) UV-rays, at a distance of 20 cm, while the control blossoms were pollinated with a mixture of other cultivated plants. Irradiation with gamma rays was carried out on a gamma device with a dose power of up to 1,500 R/m. The results show that irradiated pollen tube with the male chromatin induces gynogenesis and seconadary diploidization. It is assumed that some of the microfragments irradiated with high doses of radiation contain a functionally active gene or the genes responsible for anthocyan synthesis. These microfragments are capable of combining with the nonirradiated mother chromatin and they become involved and operate in the process of development of the mother sex cells and at the early embryogenesis, as a result of which anthocyan appears in the developing plants

  15. The source regime for irradiation plant operated with fuel elements

    International Nuclear Information System (INIS)

    Suckow, W.

    1976-11-01

    The rapid and irregular decay of the gamma radiation from reactor fuel elements requires the establishment of an optimal source regime in order to utilise reactor fuel elements as radiation sources on a technological basis. Critical values have been derived which enable the determination of optimal conditions. In this context all technologically interesting types of source regimes have been examined. Methods to achieve a high gamma yield and a satisfactory dose consistency with time have been developed and important values for these two aspects have been derived. The conditions for optimal radiation source regimes are described in the final conclusions. (author)

  16. Formation of amino acids by cobalt-60 irradiation of hydrogen cyanide solutions

    Science.gov (United States)

    Sweeney, M. A.; Toste, A. P.; Ponnamperuma, C.

    1976-01-01

    Experiments were conducted to study the pathway for the prebiotic origin of amino acids from hydrogen cyanide (HCN) under the action of ionizing radiation considered as an effective source of energy on the primitive earth. The irradiations were performed in a cobalt-60 source with a dose rate of 200,000 rad/hr. Seven naturally occurring amino acids are identified among the products formed by the hydrolysis of gamma-irradiated solutions of HCN: glycine, alanine, valine, serine, threonine, aspartic acid, and glutamic acid. The identity of these amino acids is established by gas chromatography and mass spectrometry. Control experiments provided evidence that the amino acids are not the result of contamination.

  17. Philosophy of regulating on food irradiation and its trend in U.S.A

    International Nuclear Information System (INIS)

    Kauffman, F.L.

    1984-01-01

    The irradiation for the treatment of certain foods has been investigated since late 1940s, and the limited application has been permitted for a number of years in the United States. But, there has been relatively little commercialization of this process. The research conducted so far indicated that the following areas would be promising for the initial utilization: hygienization of spices, the control of insect infestation in fruits, the control of foodborne germs, the prolongation of fruit storage life, etc. On the other hand, the irradiated food regulations by the Food and Drug Administration have proceeded as follows: the source of irradiation was determined to be a food additive - 1958, the labeling of irradiated products was required - 1966, the advance notice of the proposed rule-making for irradiated foods was published - 1981, the irradiation of spices was approved - 1983. (Mori, K.)

  18. Flat Ge-doped optical fibres for food irradiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Noor, N. Mohd; Jusoh, M. A. [Department of Imaging, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Razis, A. F. Abdull [Food Safety Research Centre, Faculty of Food Science and Technology, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Laboratory of UPM-MAKNA Cancer Research, Institute of Bioscience, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Alawiah, A. [Faculty of Engineering and Technology, Multimedia University, 75450 Malacca (Malaysia); Bradley, D. A. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom); Department of Physics, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2015-04-24

    Exposing food to radiation can improve hygiene quality, germination control, retard sprouting, and enhance physical attributes of the food product. To provide for food safety, radiation dosimetry in irradiated food is required. Herein, fabricated germanium doped (Ge-doped) optical fibres have been used. The fibres have been irradiated using a gamma source irradiator, doses in the range 1 kGy to 10 kGy being delivered. Using Ge-doped optical fibres of variable size, type and dopant concentration, study has been made of linearity, reproducibility, and fading. The thermoluminescence (TL) yield of the fibres were obtained and compared. The fibres exhibit a linear dose response over the investigated range of doses, with mean reproducibility to within 2.69 % to 8.77 %, exceeding the dose range of all commercial dosimeters used in evaluating high doses for the food irradiation industry. TL fading of the Ge-doped flat fibres has been found to be < 13%.

  19. Flat Ge-doped optical fibres for food irradiation dosimetry

    International Nuclear Information System (INIS)

    Noor, N. Mohd; Jusoh, M. A.; Razis, A. F. Abdull; Alawiah, A.; Bradley, D. A.

    2015-01-01

    Exposing food to radiation can improve hygiene quality, germination control, retard sprouting, and enhance physical attributes of the food product. To provide for food safety, radiation dosimetry in irradiated food is required. Herein, fabricated germanium doped (Ge-doped) optical fibres have been used. The fibres have been irradiated using a gamma source irradiator, doses in the range 1 kGy to 10 kGy being delivered. Using Ge-doped optical fibres of variable size, type and dopant concentration, study has been made of linearity, reproducibility, and fading. The thermoluminescence (TL) yield of the fibres were obtained and compared. The fibres exhibit a linear dose response over the investigated range of doses, with mean reproducibility to within 2.69 % to 8.77 %, exceeding the dose range of all commercial dosimeters used in evaluating high doses for the food irradiation industry. TL fading of the Ge-doped flat fibres has been found to be < 13%

  20. Experience with irradiation of table potatoes in the CSSR

    International Nuclear Information System (INIS)

    Kubin, K.

    1984-01-01

    In the years 1976 to 1980 the effect of gamma radiation on potatoes was tested. The following parameters were monitored: weight losses of tubers, sprouting and weight of sprouts, changes in chemical composition of tubers, the development of storage diseases and the interest of consumers in irradiated potatoes. The tests were made on 5 potato species. Irradiation was carried out in three time intervals with 60 Gy, 100 Gy and 150 Gy applied from a source with an activity of 4.07x10 14 Bq. Weight losses were on average higher in irradiated potatoes than in the control group. Positive was the reduced sprouting rate at 100 Gy. No substantial changes were found in chemical composition. The development of storage diseases was found to be more dependent on previous gathering and sorting, in some species it increased after irradiation in others it dropped after the 100 Gy dose. The inquiry failed and the potatoes were sold without the buyers having expressed their views. (J.P.)