WorldWideScience

Sample records for ironiii chloride barium

  1. Sulphate analysis in uranium leach iron(III) chloride solutions by inductively coupled argon plasma spectrometry

    International Nuclear Information System (INIS)

    Nirdosh, I.; Lakhani, S.; Yunus, M.Z.M.

    1993-01-01

    Inductively coupled Argon Plasma Spectrometry is used for the indirect determination of sulphate in iron(III) chloride leach solution of Elliot Lake uranium ores via addition of a known amount of barium ions and analyzing for excess of barium. The ore contains ∼ 7 wt% pyrite, FeS 2 , as the major mineral which oxidizes to generate sulphate during leaching with Fe(III). The effects of pH, the concentrations of Fe(III) and chloride ions and for presence of ethanol in the test samples on the accuracy of analysis are studied. It is found that unlike the Rhodizonate method, removal of iron(III) from or addition of ethanol to the test sample prior to analysis are not required. Linear calibration curves are obtained. (author)

  2. On barium oxide solubility in barium-containing chloride melts

    International Nuclear Information System (INIS)

    Nikolaeva, Elena V.; Zakiryanova, Irina D.; Bovet, Andrey L.; Korzun, Iraida V.

    2016-01-01

    Oxide solubility in chloride melts depends on temperature and composition of molten solvent. The solubility of barium oxide in the solvents with barium chloride content is essentially higher than that in molten alkali chlorides. Spectral data demonstrate the existence of oxychloride ionic groupings in such melts. This work presents the results of the BaO solubility in two molten BaCl 2 -NaCl systems with different barium chloride content. The received data together with earlier published results revealed the main regularities of BaO solubility in molten BaO-BaCl 2 -MCl systems.

  3. 75 FR 19657 - Barium Chloride From China

    Science.gov (United States)

    2010-04-15

    ... China AGENCY: United States International Trade Commission. ACTION: Notice of Commission determination... China. SUMMARY: The Commission hereby gives notice that it will proceed with a full review pursuant to... antidumping duty order on barium chloride from China would be likely to lead to continuation or recurrence of...

  4. 75 FR 20625 - Barium Chloride From China

    Science.gov (United States)

    2010-04-20

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-149 (Third Review)] Barium Chloride From China AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject review. DATES: Effective Date: April 9, 2010. FOR FURTHER INFORMATION CONTACT: Amy Sherman (202-205-3289...

  5. 75 FR 33824 - Barium Chloride From China

    Science.gov (United States)

    2010-06-15

    ... China Determination On the basis of the record\\1\\ developed in the subject five-year review, the United... China would be likely to lead to continuation or recurrence of material injury to an industry in the... contained in USITC Publication 4157 (June 2010), entitled Barium Chloride from China: Investigation No. 731...

  6. Scientific Opinion on the safety of the complexation product of sodium tartrate and iron(III) chloride as a food additive

    OpenAIRE

    2015-01-01

    The complexation product of sodium tartrates and iron(III) chloride (Fe mTA) is proposed for use as an anti-caking agent, only in salt or its substitutes, with a maximum use level of 106 mg Fe mTA/kg salt. Fe mTA can be expected to dissociate into its constituent iron(III) and tartrate components upon ingestion. Studies in rats demonstrated that up to 90 % of ingested DL-tartrate or tartaric acid were absorbed, studies in humans suggested that only 20 % of an ingested dose of tartaric acid we...

  7. Extraction of iron(III) with diphenyl-2-pyridylmethane dissolved in benzene from aqueous chloride solutions

    International Nuclear Information System (INIS)

    Suhail Ahmed; Shamas-Ud-Zuha; Abdul Ghafoor; Ejaz, M.

    1978-01-01

    The mechanism of extraction has been investigated by partition, slope analysis and loading-ratio data. The results obtained give a picture of the mechanism of extraction of FeCl 4 - ions in relation to the hydration and solvation of the compound extracted. The possible formula of the extracted species is (DPPM)sub(3)Hsub(3)Osup(+)(Hsub(2)O)sub(n)-FeClsub(4)sup(-). In dilute aqueous hydrochloric acid systems the influence of the concentration of a number of salts with cations of different electrical potentials (Ze/r), on iron(III) extraction, has been studied. Splitting of the organic phases occurs at high acid and/or high salt concentrations. The phenomenon is explained on the basis of the variability of the hydration number. Investigations have been made to understand the parameters controlling the extraction of the metal and it is shown that the extraction offers a simple, fast and selective separation method of iron from solutions. (author)

  8. 75 FR 36629 - Barium Chloride From the People's Republic of China: Continuation of Antidumping Duty Order

    Science.gov (United States)

    2010-06-28

    ... People's Republic of China: Continuation of Antidumping Duty Order AGENCY: Import Administration... Commission (``ITC'') that revocation of the antidumping duty order on barium chloride from the People's... (``the Act''). See Initiation of Five-year (``Sunset'') Review, 74 FR 31412 (July 1, 2009). As a result...

  9. Integrated treatment of acid mine drainage using cryptocrystalline magnesite and barium chloride

    CSIR Research Space (South Africa)

    Masindi, Vhahangwele

    2017-08-01

    Full Text Available This study endeavours to report the efficiency of a hybrid approach in the treatment of acid mine drainage. Cryptocrystalline magnesite was used to pre-treat acid mine drainage and barium chloride was used to remove the residual sulphate through...

  10. Iron(III) chloride catalyzed glycosylation of peracylated sugars with allyl/alkynyl alcohols

    Energy Technology Data Exchange (ETDEWEB)

    Narayanaperumal, Senthil; Silva, Rodrigo Cesar da; Monteiro, Julia L.; Correa, Arlene G.; Paixao, Marcio W., E-mail: mwpaixao@ufscar.br [Universidade Federal de Sao Carlos (UFSCAR), SP (Brazil). Dept. de Quimica

    2012-11-15

    In this work, the use of ferric chloride as an efficient catalyst in glycosylation reactions of sugars in the presence of allyl and alkynyl alcohols is described. The corresponding glycosides were obtained with moderate to good yields. This new procedure presented greater selectivity when compared to classic methods found in the literature. Principal features of this simple method include non-hazardous reaction conditions, low-catalyst loading, good yields and high anomeric selectivity (author)

  11. Barium determination in gastric contents, blood and urine by inductively coupled plasma mass spectrometry in the case of oral barium chloride poisoning.

    Science.gov (United States)

    Łukasik-Głębocka, Magdalena; Sommerfeld, Karina; Hanć, Anetta; Grzegorowski, Adam; Barałkiewicz, Danuta; Gaca, Michał; Zielińska-Psuja, Barbara

    2014-01-01

    A serious case of barium intoxication from suicidal ingestion is reported. Oral barium chloride poisoning with hypokalemia, neuromuscular and cardiac toxicity, treated with intravenous potassium supplementation and hemodialysis, was confirmed by the determination of barium concentrations in gastric contents, blood, serum and urine using the inductively coupled plasma mass spectrometry method. Barium concentrations in the analyzed specimens were 20.45 µg/L in serum, 150 µg/L in blood, 10,500 µg/L in urine and 63,500 µg/L in gastric contents. Results were compared with barium levels obtained from a non-intoxicated person. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Eliminating radium from uranium mill acid effluent with barium chloride-sodium carbonate precipitation

    International Nuclear Information System (INIS)

    Xiao Jiayuan

    1998-01-01

    The eliminating radium procedure, barium chloride-sodium carbonate-sand filtering, being used, radium can be eliminated to 3.7 x 10 -2 Bq/L order of magnitude from uranium mill acid effluents which contain 3.7 Bq/L Ra and pH 6∼9 when Ba 2+ is added by 3∼5 mg per litre, Na 2 CO 3 5mg. The radium elimination rate is more than 90%

  13. A Preliminary Trial on the Use of Barium Chloride for Pregnancy Diagnosis in Sows

    Directory of Open Access Journals (Sweden)

    Ndu, A.

    2000-01-01

    Full Text Available Urine was collected twice daily (once in the morning and once in the afternoon for 5 days from 80 Yorkshire x Landrace crossbred gilts/sows made up of 40 non-pregnant and 40 pregnant pigs in an investigation to determine the possibility of using 1 % barium chloride solution for pregnancy diagnosis in pigs based on a previous report that addition of a few drops of 1 % barium chloride solution to bovine urine caused a white precipitate with non-pregnant but not with pregnant cows. The pregnant pigs were in various stages of gestation. Urine reaction to 1 % barium chloride was highly (P <0.01 dependent on the pregnancy status of the sows, the test being 100 % and 81 % effective in identifying non-pregnant and pregnant sows respectively. The sensitivity of the test in the gravid sows was significantly (P <0.05 influenced by and tended to increa-se with the stage of gestation, with 59 % of the sows in their first stage of gestation (<38 days post-coitum being correctly diagnosed as pregnant, and 95-100 % of those in their latter stages of gestation being so correctly diagnosed. Parity and time of day of performance of the test had no effect on urine reaction. It was concluded that the test was at least 95 % accurate when used as from about 39 days after breeding for pregnancy diagnosis in sows.

  14. Inconceivable Hypokalemia: A Case Report of Acute Severe Barium Chloride Poisoning

    Directory of Open Access Journals (Sweden)

    Haibo Tao

    2016-01-01

    Full Text Available Barium is a heavy divalent alkaline earth metal that has been known as a muscle poison. Barium can cause human toxicity, which may lead to significant hypokalemia and have serious consequences. This paper reports a case of unprecedented barium intoxication in which the patient, who suffered from depression, swallowed at least 3.0 g barium chloride to commit suicide. On admission, the patient presented with nausea, vomiting, stomach burning feeling, dizziness, and weakness. Emergency biochemical testing showed that the patient was suffering from severe hypokalemia (K+ 1.7 mmol/L. His electrocardiogram (ECG prompted atrioventricular blocking, ventricular tachycardia, prolongation of PR interval, ST segment depression with U waves, and T wave inversion. Intravenous potassium supplements were given immediately to correct hypokalemia and regular monitoring of vital signs and fluid balance was arranged. After all-out rescue of our hospital personnel, the condition of the patient is currently stable and he is gradually recovering. This case exemplifies the weaknesses of the management of toxic substances and the lack of mental health education for young people. We hope to get more attention for the supervision of toxic substances and the healthy development of young people.

  15. Effects of barium chloride treatment of uranium mill tailings and ore on radon emanation and 226Ra levels. Progress report

    International Nuclear Information System (INIS)

    Ibrahim, S.A.; Flot, S.L.

    1983-01-01

    The purpose of this study was to investigate the effect of barium chloride treatments on: reduction of 222 Rn emanation from mill wastes; reduction of 226 Ra levels in wastewater; and decreased leachability of 226 Ra from mill wastes. Baseline 226 Ra concentrations were determined for ore and tailings as well as radon emanation fractions. Uranium ore was treated with soluble barium at concentrations of 10, 25, 50, and 100 mg per litre of slurry. The leach-liquor declined in 226 Ra concentration by as much as 50%. When soluble potassium as well as barium was used in the treatment process at equal concentrations of 10, 25, 50, and 100 mg per litre of slurry, a similar reduction was observed. No significant difference was noted between the two treatment regimes. An accelerated leaching experiment was performed on the ore treated with barium chloride. All treatment groups except that treated with 10 mg of soluble barium per litre of slurry showed significant decreases in leachability. Available 222 Rn (corresponds with radon emanation fraction) was measured in treated and untreated ore. Ore treated with concentrations of Ba ++ up to 1.00 mg per gram of ore did not show a statistically significant reduction in available 222 Rn, however when potassium sulfate was also added, a significant decline was noted. This study suggests that barium chloride treatments reduce radon emanation from mill wastes and reduce 226 Ra levels in wastewater. Leachability of 226 Ra from treated samples decreased markedly. 19 references, 8 figures, 7 tables

  16. Treatment of acidic mine water at uranium mine No. 711 by barium chloride-sludge recycle-fractional neutralization process

    International Nuclear Information System (INIS)

    Yang Chaowen; Wang Benyi; Ding Tongsen; Zhong Pingru; Liao Yongbing; Li Xiaochu; Lu Guohua

    1994-01-01

    The barium chloride-sludge recycle-fractional neutralization process for disposal of acidic mine water at Uranium Mine No. 711 was checked through laboratory and enlarged tests and one-year industrial trial-run. The results showed that the presented technology can meet the requirements of production and environmental protection

  17. Barium chloride induces redox status unbalance, upregulates cytokine genes expression and confers hepatotoxicity in rats-alleviation by pomegranate peel.

    Science.gov (United States)

    Elwej, Awatef; Grojja, Yousri; Ghorbel, Imen; Boudawara, Ons; Jarraya, Raoudha; Boudawara, Tahia; Zeghal, Najiba

    2016-04-01

    The present study was performed to establish the therapeutic efficacy of pomegranate peel against barium chloride induced liver injury. Adult rats were divided into four groups of six animals each: group I, serving as controls, received distilled water; group II received by their drinking water 67 ppm of BaCl2; group III received both 67 ppm of BaCl2 by the same way than group II and 5 % of pomegranate peel (PP) via diet; group IV received 5 % of PP. Analysis by HPLC/MS of PP showed its rich composition in flavonoids such as gallic acid, castalin, hyperin, quercitrin, syringic acid, and quercetin. The protective effects of pomegranate peel against hepatotoxicity induced by barium chloride were assessed using biochemical parameters and histological studies. Exposure of rats to barium caused oxidative stress in the liver as evidenced by an increase in malondialdehyde (MDA), lipid hydroperoxides (LOOHs), H2O2 and advanced oxidation protein product (AOPP) levels, and lactate dehydrogenase (LDH), gamma glutamyl transpeptidase (GGT), alanine aminotransferase (AST) and aspartate aminotransferase (ALT) activities, a decrease in catalase (CAT) and glutathione peroxidase (GPx) activities, glutathion (GSH), non-protein thiol (NPSH), vitamin C levels, and Mn-SOD gene expression. Liver total MT levels, MT-1, and MT-2 and pro-inflammatory cytokine genes expression like TNF-α, IL-1β and IL-6 were increased. Pomegranate peel, supplemented in the diet of barium-treated rats, showed an improvement of all the parameters indicated above.The present work provided ethnopharmacological relevance of pomegranate peel against the toxic effects of barium, suggesting its beneficial role as a potential antioxidant.

  18. Toxicological studies and antimicrobial properties of some Iron(III ...

    African Journals Online (AJOL)

    Two iron(III) complexes of Ciprofloxacin were synthesized by reaction of the ligand with iron(III) chloride hexahydrate in different solutions. The nature of bonding of the ligands and the structure of the isolated metal complexes were elucidated on the basis of their physical and spectroscopic studies. The infrared spectra ...

  19. Crystal growth and structure of the barium chloride nitrido-tantalate(V) Ba_3Cl_2TaN_3

    International Nuclear Information System (INIS)

    Blaschkowski, Bjoern; Duerr, Oliver; Reckeweg, Olaf; Schleid, Thomas

    2015-01-01

    Transparent, light yellow single crystals of the barium chloride nitridotantalate(V) Ba_3Cl_2TaN_3 (hexagonal, P6_3cm; a = 1507.39(8) pm, c = 632.98(3) pm, c/a = 0.420; Z = 6) are obtained by the reaction of the barium azide chloride Ba(N_3)Cl or its ternary decomposition products with the container wall of arc-welded tantalum ampoules at 900 C after four days. Its crystal structure displays one-dimensional chains "1_∞{[TaN_2_/_2N_2_/_1]"4"-} consisting of corner-sharing [TaN_4]"7"- tetrahedra (d(Ta-N) = 191-200 pm), which run along [001] and arrange as hexagonal rod packing. Charge compensation of these parallel "1_∞{[TaN_3]"4"-} strands occurs via Ba"2"+ cations and Cl"- anions erecting a three-dimensional network "3_∞{[Ba_3Cl_2]"4"+} (d(Ba-Cl) = 318-339 pm) with narrow channels apt to embed the chains. Several Ba-N contacts ranging between 264 and 319 pm secure the interconnection between both structural arrays and complete the coordination numbers of the Ba"2"+ cations to seven or eight. (Copyright copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Non-invasive Pregnancy Diagnosis from Urine by the Cuboni Reaction and the Barium Chloride Test in Donkeys (Equus asinus) and Alpacas (Vicugna pacos).

    Science.gov (United States)

    Kubátová, A; Fedorova, T; Skálová, I; Hyniová, L

    2016-09-01

    The aim of the research was to evaluate two chemical tests for non-invasive pregnancy diagnosis from urine, the Cuboni reaction and the barium chloride test, in donkeys (Equus asinus) and alpacas (Vicugna pacos). The research was carried out from April 2013 to September 2014. Urine samples were collected on five private Czech farms from 18 jennies and 12 alpaca females. Urine was collected non-invasively into plastic cups fastened on a telescopic rod, at 6-9 week intervals. In total, 60 and 54 urine samples from alpacas and jennies, respectively, were collected. The Cuboni reaction was performed by the State Veterinary Institute Prague. The barium chloride test was done with 5 ml of urine mixed together with 5 ml of 1% barium chloride solution. Results of the Cuboni reaction were strongly influenced by the reproductive status of jennies; the test was 100% successful throughout the second half of pregnancy. However, no relationship was found between the real reproductive status of alpaca females and results of the Cuboni reaction. It was concluded that the barium chloride test is not suitable for pregnancy diagnosis either in donkeys, due to significant influence of season on the results, or in alpacas, because no relationship between results of the test and the reproductive status of alpaca females was found. In conclusion, the Cuboni reaction has potential to become a standard pregnancy diagnostic method in donkeys.

  1. Zinc chloride modified electronic transport and relaxation studies in barium-tellurite glasses

    Science.gov (United States)

    Dhankhar, Sunil; Kundu, R. S.; Rani, Sunita; Sharma, Preeti; Murugavel, S.; Punia, Rajesh; Kishore, N.

    2017-09-01

    The ac conductivity of halide based tellurium glasses having composition 70 TeO2-(30-x) BaO-x ZnCl2; x = 5, 10, 15, 20 and 25 has been investigated in the frequency range 10-1 Hz to 105Hz and in the temperature range 453 K to 553 K. The frequency and temperature dependent ac conductivity show mixed behaviour with increase in halide content and found to obey Jonscher's universal power law. The values of dc conductivity, crossover frequency and frequency exponent have been estimated from the fitting of experimental data of ac conductivity with Jonscher's universal power law. For determining the conduction mechanism in studied glass system, frequency exponent has been analyzed by various theoretical models. In presently studied glasses, the ac conduction takes place via overlapping large polaron tunneling (OLPT). The values of activation energy for dc conduction (W) and the one associated with relaxation process ( E R) are found to increase with increase in x up to glass sample with x = 15 and thereafter it decrease with increase in zinc chloride content. DC conduction takes place via variable range hopping (VRH) as proposed by Mott with some modification suggested by Punia et al. The value of real part of modulus ( M') is observed to decrease with increase in temperature. The value of stretched exponent (β) obtained from fitting of M'' reveals the presence of non-Debye type of relaxation in presently studied glass samples. Scaling spectra of ac conductivity and values of electric modulus ( M' and M'') collapse into a single master curve for all the compositions and temperatures. The values of relaxation energy ( E R) for all the studied glass compositions are almost equal to W, suggesting that polarons have to overcome same barrier while relaxing and conducting. The conduction and relaxation processes in the studied glass samples are composition and temperature independent. [Figure not available: see fulltext.

  2. Isotopic exchange reaction between barium ion and tri barium phosphate

    International Nuclear Information System (INIS)

    Bilgin, G.B.; Cetin, I.

    1982-01-01

    Heterogeneous exchange reaction of tri barium phosphate in barium chloride solution has been studied using 133 Ba as a tracer. The results show that the exchange fraction increases as barium chloride concentration increases for different mole ratio of the exchange ion on the solid surface and in the solution. The phenomenon was studied with respect to the previous treatment of the precipitate leading to different crystal sizes and the effect of reaction time. (author)

  3. Barium enema

    Science.gov (United States)

    ... series; Colorectal cancer - lower GI series; Colorectal cancer - barium enema; Crohn disease - lower GI series; Crohn disease - barium enema; Intestinal blockage - lower GI series; Intestinal blockage - ...

  4. Chlorides retention of barium and chromium in two mangrove species Avicennia germinans and Rhizophora mangrove, developed in waters of the oil industry production, by means of the technique of hydroponics cultivation

    International Nuclear Information System (INIS)

    Grosso, J L; Sanchez L E; Avendano D; Restrepo, R

    2000-01-01

    The objective of the present study was to determine the phytoremediation mechanism (phytoextraction y/o rhizofiltration) given by the mangroves Rhizophora mangle and Avicennia germinans, when exposed to waters from an oil production field applying the hidroponia technique like system for growing the species. Determination of chlorides, barium and chromium bioaccumulation in tissues of mangrove species under study was compared with content of these elements in an inert substrate without mangroves. Bioaccumulation of the targeted elements was measured after 308 days exposure of the mangroves to production waters with initial barium and chromium contents of 1.25 g.m -3 and 0.002 g.m -3 respectively, and salinity in the range of 2,000 to 3,000 mg.kg -1 . Bioaccumulation of the studied elements (chlorides, barium and chromium) in tissues of both species was correlated to the increment in biomass of each species, as well as to the general physical condition of the plants. Survival rates higher than 95% of the exposed plants to production water during the time of study, increment in biomass of up to 5.88 g.day -1 , and concentrations of chlorides in tissues in the 0 - 170,000 mg.kg -1 during the considered period were observed. No significant difference between the two mangrove species was obtained. Bioaccumulation in tissues does not cause symptoms of deficiency in growing rates in the studied plants compared to natural rate indexes. Similarly, the analyses of inert substrate around the mangrove roots showed chloride and barium concentrations, contrary to the results of the targeted elements in the inert substrate when mangroves are not present. Both phytoremediation mechanisms were observed for the two mangrove species

  5. NTP Toxicology and Carcinogenesis Studies of Barium Chloride Dihydrate (CAS No. 10326-27-9) in F344/N Rats and B6C3F1 Mice (Drinking Water Studies).

    Science.gov (United States)

    1994-01-01

    Barium chloride dihydrate, a white crystalline granule or powder, is used in pigments, aluminum refining, leather tanning and coloring, the manufacture of magnesium metal, ceramics, glass, and paper products, as a pesticide, and in medicine as a cardiac stimulant. Toxicology and carcinogenicity studies were conducted by administering barium chloride dihydrate (99% pure) in drinking water to F344/N rats and B6C3F1 mice for 15 days, 13 weeks, and 2 years. Genetic toxicology studies were conducted in Salmonella typhimurium, cultured Chinese hamster ovary cells, and mouse lymphoma cells. 15-DAY STUDY IN RATS: Groups of five males and five females received barium chloride dihydrate in the drinking water at concentrations of 0, 125, 250, 500, 1,000, or 2,000 ppm for 15 days, corresponding to average daily doses of 10, 15, 35, 60, or 110 mg barium/kg body weight to males and females. No chemical-related deaths, differences in final mean body weights, or clinical findings of toxicity were observed. Water consumption by male and female rats exposed to 2,000 ppm was slightly less (S16%) than controls during week 2. There were no significant differences in absolute or relative organ weights between exposed and control rats. No biologically significant differences in hematology, clinical chemistry, or neurobehavioral parameters occurred in rats. 15-DAY STUDY IN MICE: Groups of five males and five females received barium chloride dihydrate in the drinking water at concentrations of 0, 40, 80,173, 346, or 692 ppm for 15 days, corresponding to average daily doses of 5,10, 20, 40, or 70 mg barium/kg body weight to males and 5, 10, 15, 40, or 85 mg barium/kg body weight to females. No chemical-related deaths, differences in mean body weights or in water consumption, or clinical findings of toxicity were observed in mice. The relative liver weight of males receiving 692 ppm was significantly greater than that of the controls. The absolute and relative liver weights of females that

  6. Chemical state analysis of iron(III) compounds precipitated homogeneously from solutions containing urea by means of Moessbauer spectrometry and x-ray diffractometry

    International Nuclear Information System (INIS)

    Ujihira, Yusuke; Ohyabu, Matashige; Murakami, Tetsuro; Horie, Tsuyoshi.

    1978-01-01

    Chemical states of iron(III) compounds, precipitated homogeneously by heating the iron(III) salt solution at 363 K in the presence of urea, was studied by means of Moessbauer spectrometry and X-ray diffractometry. The pH-time relation of urea hydrolysis revealed that the precipitation process from homogeneous solution is identical to the hydrolysis of iron(III) ion at pH around 2 under the homogeneous supply of OH - ion, which is generated by hydrolysis of urea. Accordingly, iron(III) oxide hydroxide or similar compounds to the hydrolysis products of iron(III) ion was precipitated by the precipitation from homogeneous solution methods. Akaganeite (β-FeOOH) was crystallized from 0.1 M iron(III) chloride solution. Goethite(α-FeOOH) and hematite(α-Fe 2 O 3 ) was precipitated from 0.1 M iron(III) nitrate solution, vigorous liberation of OH - ion favoring the crystallization of hematite. The addition of chloride ion to the solution resulted in the formation of akaganeite. Basic salt of iron sulfate[NH 4 Fe 3 (OH) 6 (SO 4 ) 2 ] and goethite were formed from 0.1 M iron(III) sulfate solution, the former being obtained in the more moderate condition of the urea hydrolysis ( 363 K). (author)

  7. Atomization mechanisms for barium in furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Styris, D.L.

    1984-01-01

    Atomic absorption spectrometry and mass spectrometry are used simultaneously in order to elucidate atomization mechanisms of barium dichloride in pyrolytic graphite, vitreous carbon, and tantalum furnaces. Gas-phase barium dicarbide is observed to appear concurrently with the free barium. Barium oxide and barium dihydroxide precursors appear with the chlorides. Surface reactions involving species that are absorbed on the various furnaces are postulated to explain the appearances of the species that are observed in the gas phase. 49 references, 4 figures, 1 table

  8. Bacterial Reduction Of Barium Sulphate By Sulphate-Reducing Bacteria

    Directory of Open Access Journals (Sweden)

    Luptáková Alena

    2015-12-01

    Full Text Available Acid mine drainage (AMD is a worldwide problem leading to contamination of water sources. AMD are characterized by low pH and high content of heavy metals and sulphates. The barium salts application presents one of the methods for the sulphates removing from AMD. Barium chloride, barium hydroxide and barium sulphide are used for the sulphates precipitation in the form of barium sulphate. Because of high investment costs of barium salts, barium sulphide is recycled from barium sulphate precipitates. It can be recycled by thermic or bacterial reduction of barium sulphate. The aim of our study was to verify experimentally the possibility of the bacterial transformation of BaSO4 to BaS by sulphate-reducing bacteria. Applied BaSO4 came from experiments of sulphates removal from Smolnik AMD using BaCl2.

  9. Application of sorption method on hydroxides for purification of some reactive from iron(III) markings

    International Nuclear Information System (INIS)

    Rakhmonberdiev, A.D.; Khamidov, B.O.

    1986-01-01

    The method of purification of solutions of citric acid, tartaric acid and their salts, potassium hydroxide, potassium nitrate and chloride, sodium perchlorate from iron (III) impurities by means of sorption method on zirconium hydroxide is elaborated. The control of iron(III) content in solutions is conducted by inversion voltammetry method with mercury-graphite electrode. It is defined that complete sorption of iron (III) ions achieves at ph =4÷14.

  10. Barium Sulfate

    Science.gov (United States)

    ... uses a computer to put together x-ray images to create cross-sectional or three dimensional pictures of the inside of the body). Barium sulfate is in a class of medications called radiopaque contrast media. It works by coating the esophagus, stomach, or ...

  11. Mononuclear non-heme iron(III)

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 123; Issue 2. Mononuclear non-heme iron(III) complexes of linear and tripodal tridentate ligands as functional models for catechol dioxygenases: Effect of -alkyl substitution on regioselectivity and reaction rate. Mallayan Palaniandavar Kusalendiran Visvaganesan.

  12. Barite (Barium)

    Science.gov (United States)

    Johnson, Craig A.; Piatak, Nadine M.; Miller, M. Michael; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Barite (barium sulfate, BaSO4) is vital to the oil and gas industry because it is a key constituent of the mud used to drill oil and gas wells. Elemental barium is an additive in optical glass, ceramic glazes, and other products. Within the United States, barite is produced mainly from mines in Nevada. Imports in 2011 (the latest year for which complete data were available) accounted for 78 percent of domestic consumption and came mostly from China.Barite deposits can be divided into the following four main types: bedded-sedimentary; bedded-volcanic; vein, cavity-fill, and metasomatic; and residual. Bedded-sedimentary deposits, which are found in sedimentary rocks with characteristics of high biological productivity during sediment accumulation, are the major sources of barite production and account for the majority of reserves, both in the United States and worldwide. In 2013, China and India were the leading producers of barite, and they have large identified resources that position them to be significant producers for the foreseeable future. The potential for undiscovered barite resources in the United States and in many other countries is considerable, however. The expected tight supply and rising costs in the coming years will likely be met by increased production from such countries as Kazakhstan, Mexico, Morocco, and Vietnam.Barium has limited mobility in the environment and exposed barium in the vicinity of barite mines poses minimal risk to human or ecosystem health. Of greater concern is the potential for acidic metal-bearing drainage at sites where the barite ores or waste rocks contain abundant sulfide minerals. This risk is lessened naturally if the host rocks at the site are acid-neutralizing, and the risk can also be lessened by engineering measures.

  13. Iron(III) Chloride mediated reduction of Bis(1-isoquinolylcarbonyl ...

    Indian Academy of Sciences (India)

    32. Ostendorf M, Romagnoli R, Cabeza Pereiro I C, Roos. E C, Moolenaar M J, Speckamp W N and Hiemstra H. 1997 Tetrahedron: Asymmetry 8 1773. 33. Wocadlo S, Massa W and Folgado J 1993 Inorg. Chim. Acta. 207 199. 34. Bedford R B, Bruce D W, Frost R M, Goodby J W and. Hird M 2004 Chem. Commun. 2822. 35.

  14. Separation of valence forms of chromium(III) and chromium(VI) by coprecipitation with iron(III) hydroxide

    International Nuclear Information System (INIS)

    Nazirmadov, B.; Khamidov, B.O.; Egorova, L.A.

    1989-01-01

    The sorption of 9.62·10 -5 M of Cr (III) and Cr (VI) with iron hydroxide in 1 M potassium nitrate and potassium chloride was investigated in relation to the pH of the medium. Experimental data on the sorption of chromium(III) and chromium(VI) with iron(III) hydroxide made it possible to determine the region of practically complete concentration of Cr (III) and Cr (VI) (pH = 3-6.5). The results from spectrophotometric investigations, calculated data on the distribution of the hydroxocationic forms of chromium(III) and the anions of chromium(IV), and their sorption by iron-(III) hydroxide made it possible to characterize the sorbability of the cationic and anionic forms of chromium in various degrees of oxidation. On this basis a method was developed for the separation of chromium(III) and chromium(VI) by coprecipitation on iron(III) hydroxide and their separation from the iron(III) hydroxide support

  15. BARIUM RECOVERY PROCESS

    Science.gov (United States)

    Blanco, R.E.

    1959-07-21

    A method of separating barium from nuclear fission products is described. In accordance with the invention, barium may be recovered from an acidic solution of neutron-irradiated fissionable material by carrying ihe barium cut of solution as a sulfate with lead as a carrier and then dissolving the barium-containing precipitate in an aqueous solution of an aliphatic diamine chelating reagent. The barium values together with certain other metallic values present in the diamine solution are then absorbed onto a cation exchange resin and the barium is selectively eluted from the resin bed with concentrated nitric acid.

  16. Moessbauer study of iron(III) salicylates

    Energy Technology Data Exchange (ETDEWEB)

    Mahesh, K; Sharma, N D; Gupta, D C [Kurukshetra Univ. (India). Dept. of Physics; Puri, D M [Kurukshetra Univ. (India). Dept. of Chemistry

    1979-07-01

    Moessbauer infrared and magnetic studies of different basic salicylates of iron(III) are reported. Comparison of observed isomer shift and quadrupole splitting with the earlier work allows to assign the trinuclear chain structure to the complexes wherein the central iron atom in the chain is considered to be octahedrally coordinated in case of salicylate and 4-aminosalicylate derivatives, and pentacoordinated for the thiosalicylate with the terminal iron atom in tetrahedral symmetry. The Moessbauer parameters and ..mu..sub(eff)-value indicate the high spin state of the central iron atom and low spin state for the terminal ones.

  17. Barium enema (image)

    Science.gov (United States)

    A barium enema is performed to examine the walls of the colon. During the procedure, a well lubricated enema tube is inserted gently into the rectum. The barium, a radiopaque (shows up on X-ray) contrast ...

  18. Study of interferences in the atomic - absorption and emission of barium in nitrous oxide/acetylene flame

    International Nuclear Information System (INIS)

    Curtius, A.J.; Couto, M.I.

    1979-01-01

    The interferences of several ions that are present in oifield water and sea water in the atomic absorption and emission of barium were investigated. It was verified that the interferences of sodium, potassium, calcium, strontium and chloride are the most important. The indirect method for the determination of sulfate by measuring barium by atomic absorption after precipitating barium sulfate with an excess of barium chloride, should not be used for highly salted matrix. To avoid the interferences that are not compensated by an ionization supressor, the measurement of barium by the standard addition method or a previous sulfate separation is recommended. (Author) [pt

  19. Preliminary experimental results of barium chloride-ammonia reaction for using in a solar thermochemical cooling cycle; Resultados experimentales preliminares de la reaccion entre el cloruro de bario y el amoniaco para su utilizacion en un ciclo de refrigeracion solar termoquimico

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, C. O. B.; Mendez, E. R.; Pilatowsky, L. F.; Rivera, W. G.

    2004-07-01

    An experimental intermittent thermochemical refrigeration system operating with barium chloride-ammonia reaction is described. The barium chloride is used as absorbent and ammonia as refrigerant. The equipment components and the experimental preliminary results are also presented. The temperature range of the thermal fluid from 70 C to 95 C was established. The main results showed that the generation temperature oscillated from 53 C to 56 C for a condensation temperature of 23 C. The generation pressure range was from 10 to 11 bar. In the evaporating-absorption process, the evaporating temperature range was between 10 C and 0 C for a saturation pressure of 2.4 bar. The results showed also, the technical feasibility to operate this refrigeration system with low cost solar flat plate collectors in remote areas. (Author) CIEMAT (Centro de Investigaciones Energeticas, Mediambientales y Tecnologicas). The LCA is an environmental management methodology with which the environmental impacts associate to a system, process product are detected. The ISO standard 14040: 1997 contain the procedure to follow. life cycle of the plant is divided in 4 stages: extraction and transformation of raw materials; transport and installation; completion of the system to operate like a steam generator maintenance, and dismantling. As result, some improvements are recommended, mainly related to changes in the types of materials and the treatment of the emissions. (Author)

  20. Magnetic interactions in iron (III) porphyrin chlorides

    International Nuclear Information System (INIS)

    Ernst, J.; Subramanian, Japyesan; Fuhrhop, J.H.

    1977-01-01

    Intermolecular exchange interactions in iron(III) porphyrin chlorides (porphyrin = OEP, proto, TPP) have been studied by X-ray structure, EPR and magnetic susceptibility studies. The crystal structure of Fe(III)OEP-Cl was found to be different from that of the other two. Different types of exchange broadened EPR-spectra are obtained which are attributable to the arrangement in the crystals. The EPR results correlate well with magnetic susceptibility data. (orig.) [de

  1. Hydrogen-Bonding Interactions Trigger a Spin-Flip in Iron(III) Porphyrin Complexes**

    Science.gov (United States)

    Sahoo, Dipankar; Quesne, Matthew G; de Visser, Sam P; Rath, Sankar Prasad

    2015-01-01

    A key step in cytochrome P450 catalysis includes the spin-state crossing from low spin to high spin upon substrate binding and subsequent reduction of the heme. Clearly, a weak perturbation in P450 enzymes triggers a spin-state crossing. However, the origin of the process whereby enzymes reorganize their active site through external perturbations, such as hydrogen bonding, is still poorly understood. We have thus studied the impact of hydrogen-bonding interactions on the electronic structure of a five-coordinate iron(III) octaethyltetraarylporphyrin chloride. The spin state of the metal was found to switch reversibly between high (S=5/2) and intermediate spin (S=3/2) with hydrogen bonding. Our study highlights the possible effects and importance of hydrogen-bonding interactions in heme proteins. This is the first example of a synthetic iron(III) complex that can reversibly change its spin state between a high and an intermediate state through weak external perturbations. PMID:26109743

  2. Reverse osmosis membrane composition, structure and performance modification by bisulphite, iron(III), bromide and chlorite exposure.

    Science.gov (United States)

    Ferrer, O; Gibert, O; Cortina, J L

    2016-10-15

    Reverse osmosis (RO) membrane exposure to bisulphite, chlorite, bromide and iron(III) was assessed in terms of membrane composition, structure and performance. Membrane composition was determined by Rutherford backscattering spectrometry (RBS) and membrane performance was assessed by water and chloride permeation, using a modified version of the solution-diffusion model. Iron(III) dosage in presence of bisulphite led to an autooxidation of the latter, probably generating free radicals which damaged the membrane. It comprised a significant raise in chloride passage (chloride permeation coefficient increased 5.3-5.1 fold compared to the virgin membrane under the conditions studied) rapidly. No major differences in terms of water permeability and membrane composition were observed. Nevertheless, an increase in the size of the network pores, and a raise in the fraction of aggregate pores of the polyamide (PA) layer were identified, but no amide bond cleavage was observed. These structural changes were therefore, in accordance with the transport properties observed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Aquachloridobis[5-(2-pyridyl-1H-tetrazolato-κN1]iron(III

    Directory of Open Access Journals (Sweden)

    Bo Wang

    2009-08-01

    Full Text Available The title compound, [Fe(C6H4N52Cl(H2O], was synthesized by hydrothermal reaction of FeCl3 with 2-(1H-tetrazol-5-ylpyridine. The iron(III metal centre exhibits a distorted octahedral coordination geometry provided by four N atoms from two bidentate organic ligands, one water O atom and one chloride anion. The pyridine and tetrazole rings are nearly coplanar [dihedral angles = 4.32 (15 and 5.04 (14°]. In the crystal structure, intermolecular O—H...N hydrogen bonds link the complex molecules into a two-dimensional network parallel to (100.

  4. Oxidation of Alcohols by Ferric Nitrate in the Presence of Barium ...

    African Journals Online (AJOL)

    NJD

    Oxidation, ferric nitrate, barium chloride, silica sulphuric acid, heterogeneous or solvent-free conditions. 1. Introduction ... economic advantage and environment protection. ... by TLC. After completion, structure of the product was charac-.

  5. Barium titanate coated with magnesium titanate via fused salt method and its dielectric property

    International Nuclear Information System (INIS)

    Chen Renzheng; Cui Aili; Wang Xiaohui; Li Longtu

    2003-01-01

    Barium titanate fine particles were coated homogeneously with magnesium titanate via the fused salt method. The thickness of the magnesium titanate film is 20 nm, as verified by TEM and XRD. The mechanism of the coating is that: when magnesium chloride is liquated in 800 deg. C, magnesium will replace barium in barium titanate, and form magnesium titanate film on the surface of barium titanate particles. Ceramics sintered from the coated particles show improved high frequency ability. The dielectric constant is about 130 at the frequency from 1 to 800 MHz

  6. Aspiration of Barium Contrast

    OpenAIRE

    Fuentes Santos, Cristina; Steen, Bárbara

    2014-01-01

    The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical fil...

  7. Toxicological studies and antimicrobial properties of some Iron(III ...

    African Journals Online (AJOL)

    SERVER

    2007-12-17

    Dec 17, 2007 ... Two iron(III) complexes of Ciprofloxacin were synthesized by reaction of the ... The infrared spectra suggest that two classes of compounds were obtained: molecular complex in .... Soluble in H2O, MeOH, EtOH; Mol. cond.

  8. Adsorption studies of iron(III)

    Indian Academy of Sciences (India)

    Adsorption of ferric ions by chitin was studied by the batch equilibration method. The influence of particle size and dosage of the adsorbant, contact time, initial concentration of the adsorbate and temperature were experimentally verified. The effect of anions like chloride, nitrate and sulphate and also of cations like zinc, ...

  9. Barium granuloma of the rectum: case report

    International Nuclear Information System (INIS)

    Kim, Dae Jin; Kim, Se Hyung; Jeoung, Ah Young; Lee, Kyoung Ho; Choi, Byung Ihn; Han, Joon Koo

    2003-01-01

    Barium granulomas usually occur after barium enema within 8 cm of the anal verge probably due to minute laceration of rectal wall by enema tip and extravasation of barium during barium enema. We report a case of barium granuloma of rectum in a 47-year-old man, who did not have history of barium enema. In rare instance, barium granuloma can occur without a history of barium enema and careful interpretation of radiologic image is essential to make a correct diagnosis

  10. Modeling and minimization of barium sulfate scale

    Science.gov (United States)

    Alan W. Rudie; Peter W. Hart

    2006-01-01

    The majority of the barium present in the pulping process exits the digester as barium carbonate. Barium carbonate dissolves in the bleach plant when the pH drops below 7 and, if barium and sulfate concentrations are too high, begins to precipitate as barium sulfate. Barium is difficult to control because a mill cannot avoid this carbonate-to-sulfate transition using...

  11. Aspiration of Barium Contrast

    Directory of Open Access Journals (Sweden)

    Cristina Fuentes Santos

    2014-01-01

    Full Text Available The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical file was reviewed, images were found of a barium swallow study that the patient had undergone months earlier, and we were able to observe the exact moment of the aspiration of the contrast material. The patient had been asymptomatic since the test.

  12. Observed Barium Emission Rates

    Science.gov (United States)

    Stenbaek-Nielsen, H. C.; Wescott, E. M.; Hallinan, T. J.

    1993-01-01

    The barium releases from the CRRES satellite have provided an opportunity for verifying theoretically calculated barium ion and neutral emission rates. Spectra of the five Caribbean releases in the summer of 1991 were taken with a spectrograph on board a U.S. Air Force jet aircraft. Because the line of sight release densities are not known, only relative rates could be obtained. The observed relative rates agree well with the theoretically calculated rates and, together with other observations, confirm the earlier detailed theoretical emission rates. The calculated emission rates can thus with good accuracy be used with photometric observations. It has been postulated that charge exchange between neutral barium and oxygen ions represents a significant source for ionization. If so. it should be associated with emissions at 4957.15 A and 5013.00 A, but these emissions were not detected.

  13. Lower GI Series (Barium Enema)

    Science.gov (United States)

    ... uses x-rays and a chalky liquid called barium to view your large intestine . The barium will make your large intestine more visible on ... single-contrast lower GI series, which uses only barium a double-contrast or air-contrast lower GI ...

  14. Synthesis of carbon-14 labelled ethyl chloride

    International Nuclear Information System (INIS)

    Kanski, R.

    1976-01-01

    A new efficient method of synthesis of ethyl chloride (1,2- 14 C), based on the Ba 14 CO 3 and dry hydrogen chloride as starting materials has been developed and described. Addition of the hydrogen chloride to ethylene (1,2- 14 C), obtained from Ba 14 CO 3 , has been carried out in the presence of the AlCl 3 as catalyst. The outlined method leads to ethyl chloride (1,2- 14 C) of high specific activity. The radiochemical yield of the reaction based on the activity of barium carbonate used was 72%. (author)

  15. Barium-induced skeletal muscle paralysis in the rat, and its relationship to human familial periodic paralysis

    Science.gov (United States)

    Schott, G. D.; McArdle, B.

    1974-01-01

    An in vivo study of skeletal muscle paralysis induced by intravenous barium chloride has been made in curarized and non-curarized rats. The influence of potassium and calcium chlorides, propranolol, ouabain, and prior adrenalectomy on the paralysis has also been studied. Paralysis is found to be due to a direct effect on skeletal muscle, and to correlate well with the development of hypokalaemia. Possible mechanisms of action of barium are discussed, and attention is drawn to the similarity between barium poisoning and hypokalaemic familial periodic paralysis. PMID:4813426

  16. Measuring marine iron(III) complexes by CLE-AdSV

    NARCIS (Netherlands)

    Town, R.M.; Leeuwen, van H.P.

    2005-01-01

    Iron(iii) speciation data, as determined by competitive ligand exchange?adsorptive stripping voltammetry (CLE-AdSV), is reconsidered in the light of the kinetic features of the measurement. The very large stability constants reported for iron(iii) in marine ecosystems are shown to be possibly due to

  17. Kinetics and mechanism of oxidation of glycine by iron(III)

    Indian Academy of Sciences (India)

    Kinetics and mechanism of oxidation of glycine by iron(III)-1,10-phenanthroline complex has been studied in perchloric acid medium. The reaction is first order with respect to iron(III) and glycine. An increase in (phenanthroline) increases the rate, while increase in [H+] decreases the rate. Hence it can be inferred that the ...

  18. Effect of iron(III) ion on moso bamboo pyrolysis under microwave irradiation.

    Science.gov (United States)

    Dong, Qing; Li, Xiangqian; Wang, Zhaoyu; Bi, Yanhong; Yang, Rongling; Zhang, Jinfeng; Luo, Hongzhen; Niu, Miaomiao; Qi, Bo; Lu, Chen

    2017-11-01

    The effect of iron(III) ion on microwave pyrolysis of moso bamboo was investigated. Hydrofluoric acid washing was used as a pilot process to demineralize moso bamboo in order to eliminate the influences of the other inorganics contained in moso bamboo itself. The results indicated that the addition of iron(III) ion increased the maximal reaction temperatures under microwave condition dependent on the amount of the added iron(III) ion. The production of the non-condensable gases was promoted by the addition of iron(III) ion mainly at the expense of liquid products. Iron(III) ion exhibited the positive effect for syngas production and inhibited the formation of CO 2 and CH 4 . The formation of Fe 2 O 3 and Fe 3 O 4 was found during microwave pyrolysis and the mechanism of the two metallic oxides formation was described in this work. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Lithium in the barium stars

    International Nuclear Information System (INIS)

    Pinsonneault, M.H.; Sneden, C.

    1984-01-01

    New high-resolution spectra of the lithium resonance doublet have provided lithium abundances or upper limits for 26 classical and mild barium stars. The lithium lines always are present in the classical barium stars. Lithium abundances in these stars obey a trend with stellar masses consistent with that previously derived for ordinary K giants. This supports the notion that classical barium stars are post-core-He-flash or core-He-burning stars. Lithium contents in the mild barium stars, however, often are much smaller than those of the classical barium stars sometimes only upper limits may be determined. The cause for this difference is not easily understood, but may be related to more extensive mass loss by the mild barium stars. 45 references

  20. Spin-crossover behavior of polymeric iron(III) complexes

    International Nuclear Information System (INIS)

    Maeda, Yonezo; Miyamoto, Makoto; Takashima, Yoshimasa; Oshio, Hiroaki

    1989-01-01

    Polymeric spin-crossover iron(III) complexes possessing poly(4-vinylpyridine), poly(N-vinylimidazole) or poly(octylmethacrylate-co-4-vinylpyridine) as ligand are prepared. In this experience enriched 57 Fe was used to get strong Moessbauer absorption. The enriched behavior of the complexes were examined by magnetic susceptibilities measurement, and Moessbauer and esr spectroscopies. Some of them show spin-state behavior over a wide range of temperature. Some of them show rapid spin-state interexchange compared to the Moessbauer time scale and others not. Spin-crossover behavior of polymeric complexes is characterized of wide spin-state transition temperature range

  1. Barium and radium radiopolarography

    International Nuclear Information System (INIS)

    Fourest, B.

    1979-01-01

    Radiopolarography has been applied to the study of two elements (barium and radium) which is difficult by classical polarography because of their strong electropositivity. Various parameters have been considered: nature, concentration and pH of supporting electrolyte. In any case of investigated mediums, the reduction to the metallic state reaction appeared to be reversible. An important variation of the barium half-wave potential E 1/2 with the ionic strength μ of the solution, imposed by LiCl used as supporting electrolyte, has been observed. It gives the possibility to estimate, for μ = 0, E 1/2 (Ba) = - 1.916 V/S.C.E. and E 1/2(Ra) = - 1.852 V/S.C.E. The values of barium and radium half wave potentials, obtained with a good accuracy in LiCl (or LiClO 4 ) 0.1 M medium, have been used to establish the amalgamation energy Δ 2 (M) of these elements. A linear variation of Δ 2 (M) with the metallic radius of the 2a elements has been obtained. On the other hand, by making the concentration of the complex forming agent (Cit 3- ) vary in the solution, we have a shift in the half wave potential from which we can deduce the stability constant of the complexe and its composition (BaCit - ; pK 1 =2). At last, nature and concentration of the supporting electrolyte (between 5.10 -2 M and 5M) have a determining influence on the extent of the polarogram plateau. This plateau is limited by an 'hollow effect' preceding the supporting electrolyte discharge. An interpretation of this effect is suggested which is based on the Stern model [fr

  2. Barium uranyl diphosphonates

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Anna-Gay D., E-mail: nelsoa@umich.edu [Department of Civil Engineering and Geological Sciences and Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 (United States); Department of Earth and Environmental Sciences, University of Michigan, Ann Arbor, MI 48109-1005 (United States); Alekseev, Evgeny V. [Institute of Energy and Climate Research (IEK-6), Forschungszentrum Juelich Wilhelm-Johnen-Strasse, Juelich 52428 (Germany); Ewing, Rodney C. [Department of Earth and Environmental Sciences, University of Michigan, Ann Arbor, MI 48109-1005 (United States); Albrecht-Schmitt, Thomas E. [Department of Civil Engineering and Geological Sciences and Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN 46556 (United States)

    2012-08-15

    Three Ba{sup 2+}/UO{sub 2}{sup 2+} methylenediphosphonates have been prepared from mild hydrothermal treatment of uranium trioxide, methylendiphosphonic acid (C1P2) with barium hydroxide octahydrate, barium iodate monohydrate, and small aliquots of HF at 200 Degree-Sign C. These compounds, Ba[UO{sub 2}[CH{sub 2}(PO{sub 3}){sub 2}]{center_dot}1.4H{sub 2}O (Ba-1), Ba{sub 3}[(UO{sub 2}){sub 4}(CH{sub 2}(PO{sub 3}){sub 2}){sub 2}F{sub 6}]{center_dot}6H{sub 2}O (Ba-2), and Ba{sub 2}[(UO{sub 2}){sub 2}(CH{sub 2}(PO{sub 3}){sub 2})F{sub 4}]{center_dot}5.75H{sub 2}O (Ba-3) all adopt layered structures based upon linear uranyl groups and disphosphonate molecules. Ba-2 and Ba-3 are similar in that they both have UO{sub 5}F{sub 2} pentagonal bipyramids that are bridged and chelated by the diphosphonate moiety into a two-dimensional zigzag anionic sheet (Ba-2) and a one-dimensional ribbon anionic chain (Ba-3). Ba-1, has a single crystallographically unique uranium metal center where the C1P2 ligand solely bridges to form [UO{sub 2}[CH{sub 2}(PO{sub 3}){sub 2}]{sup 2-} sheets. The interlayer space of the structures is occupied by Ba{sup 2+}, which, along with the fluoride ion, mediates the structure formed and maintains overall charge balance. - Graphical abstract: Illustration of the stacking of the layers in Ba{sub 3}[(UO{sub 2}){sub 4}(CH{sub 2}(PO{sub 3}){sub 2}){sub 2})F{sub 6}]{center_dot}6H{sub 2}O viewed along the c-axis. The structure is constructed from UO{sub 7} pentagonal bipyramidal units, U(1)O{sub 7}=gray, U(2)O{sub 7}=yellow, barium=blue, phosphorus=magenta, fluorine=green, oxygen=red, carbon=black, and hydrogen=light peach. Highlights: Black-Right-Pointing-Pointer The polymerization of the UO{sub 2}{sup 2+} sites to form uranyl dimers leads to structural variations in compounds. Black-Right-Pointing-Pointer Barium cations stitch uranyl diphosphonate anionic layers together, and help mediate structure formation. Black-Right-Pointing-Pointer HF acts as both a

  3. Barium toxicosis in a dog.

    Science.gov (United States)

    Adam, Fiona H; Noble, Peter J M; Swift, Simon T; Higgins, Brent M; Sieniawska, Christine E

    2010-09-01

    A 2-year-old 14.9-kg (32.8-lb) neutered female Shetland Sheepdog was admitted to the University of Liverpool Small Animal Teaching Hospital for evaluation of acute collapse. At admission, the dog was tachypneic and had reduced limb reflexes and muscle tone in all limbs consistent with diffuse lower motor neuron dysfunction. The dog was severely hypokalemic (1.7 mEq/L; reference range, 3.5 to 5.8 mEq/L). Clinical status of the dog deteriorated; there was muscle twitching, flaccid paralysis, and respiratory failure, which was considered a result of respiratory muscle weakness. Ventricular arrhythmias and severe acidemia (pH, 7.18; reference range, 7.35 to 7.45) developed. Intoxication was suspected, and plasma and urine samples submitted for barium analysis had barium concentrations comparable with those reported in humans with barium toxicosis. Analysis of barium concentrations in 5 control dogs supported the diagnosis of barium toxicosis in the dog. Fluids and potassium supplementation were administered IV. The dog recovered rapidly. Electrolyte concentrations measured after recovery were consistently unremarkable. Quantification of plasma barium concentration 56 days after the presumed episode of intoxication revealed a large decrease; however, the plasma barium concentration remained elevated, compared with that in control dogs. To our knowledge, this case represented the first description of barium toxicosis in the veterinary literature. Barium toxicosis can cause life-threatening hypokalemia; however, prompt supportive treatment can yield excellent outcomes. Barium toxicosis is a rare but important differential diagnosis in animals with hypokalemia and appropriate clinical signs.

  4. Sorption of small amounts of europium(III) on iron(III) hydroxide and oxide

    International Nuclear Information System (INIS)

    Music, S.; Gessner, M.; Wolf, R.H.H.

    1979-01-01

    The sorption of small amounts of europium(III) on iron(III) hydroxide and oxide has been studied as a function of pH. The mechanism of sorption is discussed. Optimum conditions have been found for the preconcentration of small or trace amounts of europium(III) by iron(III) hydroxide and oxide. The influence of complexing agents (EDTA, oxalate, tartrate and 5-sulfosalicylic acid) on the sorption of small amounts of europium(III) on iron(III) oxide has also been studied. (author)

  5. The Novel Formation of Barium Titanate Nanodendrites

    Directory of Open Access Journals (Sweden)

    Chien-Jung Huang

    2014-01-01

    Full Text Available The barium titanate (BaTiO3 nanoparticles with novel dendrite-like structures have been successfully fabricated via a simple coprecipitation method, the so-called BaTiO3 nanodendrites (BTNDs. This method was remarkable, fast, simple, and scalable. The growth solution is prepared by barium chloride (BaCl2, titanium tetrachloride (TiCl4, and oxalic acid. The shape and size of BaTiO3 depend on the amount of added BaCl2 solvent. To investigate the influence of amount of BaCl2 on BTNDs, the amount of BaCl2 was varied in the range from 3 to 6 mL. The role of BaCl2 is found to have remarkable influence on the morphology, crystallite size, and formation of dendrite-like structures. The thickness and length of the central stem of BTND were ~300 nm and ~20 μm, respectively. The branchings were found to occur at irregular intervals along the main stem. Besides, the formation mechanism of BTND is proposed and discussed.

  6. Chloride Test

    Science.gov (United States)

    ... metabolic acidosis ) or when a person hyperventilates (causing respiratory alkalosis ). A decreased level of blood chloride (called hypochloremia) ... disease , emphysema or other chronic lung diseases (causing respiratory ... metabolic alkalosis). An increased level of urine chloride can indicate ...

  7. MR Colonography with fecal tagging: Barium vs. barium ferumoxsil

    DEFF Research Database (Denmark)

    Achiam, M.P.; Chabanova, E.; Logager, V.B.

    2008-01-01

    and Methods. Twenty patients referred to CC underwent dark lumen MRC prior to the colonoscopy. Two groups of patients received two different oral contrast agents (barium sulfate and barium sulfate/ferumoxsil) as a laxative-free fecal tagging prior to the MRC. After MRC, the contrast agent was rated...... qualitatively (with the standard method using contrast-to-wall ratio) and subjectively (using a visual analog scale [VAS]) by three different blinded observers. Results. Evaluated both qualitatively and subjectively, the tagging efficiency of barium sulfate/ferumoxsil was significantly better (P ... barium sulfate alone. The VAS method for evaluating the tagging efficiency of contrast agents showed a high correlation (observer 11, r = 0.91) to the standard method using contrast-to-wall ratio and also a high interclass correlation (observer 11 and III = 0.89/0.85). MRC found I of 22 (5%) polyps

  8. Barium aluminate cement: its application

    International Nuclear Information System (INIS)

    Drozdz, M.; Wolek, W.

    1975-01-01

    The technology of manufacturing barium aluminate cement from barium sulfate and alumina, using a rotary kiln for firing the clinker is described. The method of granulation of the homogenized charge was used. Conditions of using the ''to mud'' method in industry were indicated. The physical and chemical properties of barium aluminate cement are determined and the quality of several batches of cement prepared on a semi-industrial scale and their suitability for making highly refractory concretes are tested. The optimal composition of the concretes is determined as a function of the mixing water and barium aluminate cement contents. Several experimental batches of concretes were used in the linings of furnaces in the steel industry. The suitability of these cements for use in fields other than steelmaking is examined. It is established that calcium aluminate cement has certain limited applications [fr

  9. Aqua complex of iron(III) and 5-chloro-3-(2-(4,4-dimethyl-2,6-dioxocyclohexylidene)hydrazinyl)-2-hydroxybenzenesulfonate: Structure and catalytic activity in Henry reaction

    Science.gov (United States)

    Mahmudov, Kamran T.; Kopylovich, Maximilian N.; Haukka, Matti; Mahmudova, Gunay S.; Esmaeila, Espandi F.; Chyragov, Famil M.; Pombeiro, Armando J. L.

    2013-09-01

    A water-soluble iron(III) complex [Fe(H2O)3(L)]·5H2O (1) was prepared by reaction of iron(III) chloride with 5-chloro-3-(2-(4,4-dimethyl-2,6-dioxocyclohexylidene)hydrazinyl)-2-hydroxy-benzenesulfonic acid (H3L). The complex was characterized by IR, 1H NMR and ESI-MS spectroscopies, elemental and X-ray crystal structural analyses. The coordination environment of the central iron(III) is a distorted octahedron, three sites being occupied by L3- ligand, which chelates in O,N,O fashion, while three other sites are filled with the water molecules. The uncoordinated water molecules are held in the channels of the overall 3D supramolecular structure by the carbonyl and sulfonyl groups of L3- and the ligated waters. Apart from the multiple hydrogen bonds, an intermolecular charge-assisted O···Cl halogen bonding with 3.044 Å distance was described. 1 acts as an effective catalyst in the Henry reaction producing nitroaldols from nitroethane and various aldehydes with yields up to 90% and threo/erythro diastereoselectivity ranging from 3:1 to 1:1.

  10. Statistical properties of barium stars

    International Nuclear Information System (INIS)

    Hakkila, J.E.

    1986-01-01

    Barium stars are G- and K-giant stars with atmospheric excesses of s-process elements, and a broadband spectral depression in the blue portion of the spectrum. The strength of the λ4554 Ball line is used as a classification parameter known as the Barium Intensity. They have a mean absolute magnitude of 1.0 and a dispersion of 1.2 magnitudes (assuming a Gaussian distribution in absolute magnitude) as measured from secular and statistical parallaxes. These stars apparently belong to a young-disk population from analyses of both the solar reflex motion and their residual velocity distribution, which implies that they have an upper mass limit of around three solar masses. There is no apparent correlation of barium intensity with either luminosity or kinematic properties. The barium stars appear to be preferentially distributed in the direction of the local spiral arm, but show no preference to associate with or avoid the direction of the galactic center. They do not appear related to either the carbon or S-stars because of these tendencies and because of the stellar population to which each type of star belongs. The distribution in absolute magnitude combined with star count analyses implies that these stars are slightly less numerous than previously believed. Barium stars show infrared excesses that correlate with their barium intensities

  11. Obtaining of barium sulfate from solution formed after desulfation of the active mass of scrap lead-acid batteries

    Directory of Open Access Journals (Sweden)

    O. A. Kalko

    2014-03-01

    Full Text Available Analyses of literature data about processes for solution utilization formed after desulfation of the active mass of scrap lead-acid batteries is performed. Optimal conditions for obtaining of barium sulfate sediment from ammonium sulfate solute and chemically pure Ba(OH2×8H2O и BaCl2×2H2O were found experimentally. In laboratory the commercial barium sulfate from sulfate solutions, that are waste of recycling process of battery scrap, with application of chloride and barium hydroxide was production. The possibility of using this product were discussed.

  12. Barium light source method and apparatus

    Science.gov (United States)

    Curry, John J. (Inventor); MacDonagh-Dumler, Jeffrey (Inventor); Anderson, Heidi M. (Inventor); Lawler, James E. (Inventor)

    2002-01-01

    Visible light emission is obtained from a plasma containing elemental barium including neutral barium atoms and barium ion species. Neutral barium provides a strong green light emission in the center of the visible spectrum with a highly efficient conversion of electrical energy into visible light. By the selective excitation of barium ionic species, emission of visible light at longer and shorter wavelengths can be obtained simultaneously with the green emission from neutral barium, effectively providing light that is visually perceived as white. A discharge vessel contains the elemental barium and a buffer gas fill therein, and a discharge inducer is utilized to induce a desired discharge temperature and barium vapor pressure therein to produce from the barium vapor a visible light emission. The discharge can be induced utilizing a glow discharge between electrodes in the discharge vessel as well as by inductively or capacitively coupling RF energy into the plasma within the discharge vessel.

  13. Development of biomonitoring equivalents for barium in urine and plasma for interpreting human biomonitoring data.

    Science.gov (United States)

    Poddalgoda, Devika; Macey, Kristin; Assad, Henry; Krishnan, Kannan

    2017-06-01

    The objectives of the present work were: (1) to assemble population-level biomonitoring data to identify the concentrations of urinary and plasma barium across the general population; and (2) to derive biomonitoring equivalents (BEs) for barium in urine and plasma in order to facilitate the interpretation of barium concentrations in the biological matrices. In population level biomonitoring studies, barium has been measured in urine in the U.S. (NHANES study), but no such data on plasma barium levels were identified. The BE values for plasma and urine were derived from U.S. EPA's reference dose (RfD) of 0.2 mg/kg bw/d, based on a lower confidence limit on the benchmark dose (BMDL 05 ) of 63 mg/kg bw/d. The plasma BE (9 μg Ba/L) was derived by regression analysis of the near-steady-state plasma concentrations associated with the administered doses in animals exposed to barium chloride dihydrate in drinking water for 2-years in a NTP study. Using a human urinary excretion fraction of 0.023, a BE for urinary barium (0.19 mg/L or 0.25 mg/g creatinine) was derived for US EPA's RfD. The median and the 95 th percentile barium urine concentrations of the general population in U.S. are below the BE determined in this study, indicating that the population exposure to inorganic barium is expected to be below the exposure guidance value of 0.2 mg/kg bw/d. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  14. Barium and iron abundances in red giants

    International Nuclear Information System (INIS)

    Fernandez-Villacanas, J.L.; Rego, M.; Cornide, M.

    1990-01-01

    An intermediate-dispersion abundance analysis has been carried out on a sample of 21 barium and 14 comparison stars. The excess of barium over iron has been used as the most representative indicator of peculiarity. These excesses are higher in the peculiar stars than in the nonpeculiar stars. Particularly interesting is the case of HD 67447, included in the comparison stars, with an excess Ba/Fe abundance = 1.61, probably a new barium star. A trend indicating a possible anticorrelation between barium overabundance and metallicity favors the suggestion that the barium strong group is older than the barium weak one. 36 refs

  15. Ionic conductivity and diffusion coefficient of barium-chloride-based ...

    Indian Academy of Sciences (India)

    styrenesulphonic acid) with bariumchloride dihydrate (BaCl 2 ·2H 2 O) salt complex has been synthesized following the usual solution casting. The ionic conductivity of polymer electrolyte was analysed by impedance spectroscopy. The highest room ...

  16. Ionic conductivity and diffusion coefficient of barium-chloride-based ...

    Indian Academy of Sciences (India)

    2017-07-26

    Jul 26, 2017 ... the present research is to reveal the effect of BaCl2 on the ionic conductivity ... pared polymer electrolyte was recorded and energy band gap was evaluated from ... The XRD analysis is useful to determine the structural and.

  17. Moessbauer spectroscopic studies of alkylammonium iron(III) complexes

    International Nuclear Information System (INIS)

    Katada, M.; Kozawa, S.; Nakajima, Y.

    2006-01-01

    Alkylammonium iron(III) complexes, [(n-C n H 2n+1 )mNH 4-m ] 3 [Fe(CN) 6 ] were prepared and studied by Moessbauer spectroscopy, XRD, and DSC. In the complexes with m=2, the temperature dependences of the area intensity of Moessbauer are correlated to the motion of alkyl chains. The temperature dependence of the complex with n=4 was linear and smaller than that of other complexes. Especially in the complex with n=6, the deviation from the linear was the largest in the complexes observed. This result is attributed to the structural difference of the complex. The complexes with n≥8 consist of two-dimensional layer structure. The temperature dependence of the area intensity was similar to each other. This means that the motion of alkyl chain in these complexes are almost the same. The values of quadrupole splitting for the complexes were larger those that of the complexes (m=1). This indicates that the form of [Fe(CN) 6 ] 3- ion is affected by the differences of the number of alkyl groups. (author)

  18. Study of Ascorbic Acid as Iron(III Reducing Agent for Spectrophotometric Iron Speciation

    Directory of Open Access Journals (Sweden)

    Antesar Elmagirbi

    2012-10-01

    Full Text Available The study of ascorbic acid as a reducing agent for iron(III has been investigated in order to obtain an alternative carcinogenic reducing agent, hydroxylamine, used in spectrophotometric standard method based on the formation of a red-orange complex of Fe(II-o-phenanthroline. The study was optimised with regards to ascorbic acid concentration as well as pH solution. The results showed that ascorbic acid showed maximum capacity as reducing agent of iron(III under concentration of 4.46.10-4 M and pH solution of 1-4.Under these conditions, ascorbic acid reduced iron(III proportionally and performed similarly to that of hydroxylamine.  The method gave result to linear calibration over the range of 0.2-2 mg/L withhigh accuracy of 97 % and relative standard deviation of less than 2 %. This method was successfully applied to assay iron speciation in water samples.

  19. Effects of polyacrylic acid additive on barium sulfate particle morphology

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jie; Liu, Dandan; Jiang, Hongkun; Wang, Jun; Jing, Xiaoyan; Chen, Rongrong [Key Laboratory of Superlight Material and Surface Technology of Ministry of Education, College of Material Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China); Zhu, Wenting [Department of Gastroenterology, Harbin Medical University Cancer Hospital, Harbin 150081 (China); Han, Shihui [Key Laboratory of Superlight Material and Surface Technology of Ministry of Education, College of Material Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China); Li, Wanyou [College of Power and Energy Engineering, Harbin Engineering University, Harbin 150001 (China); Wei, Hao, E-mail: weihao7512@126.com [Key Laboratory of Superlight Material and Surface Technology of Ministry of Education, College of Material Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China); College of Power and Energy Engineering, Harbin Engineering University, Harbin 150001 (China)

    2016-06-01

    In this paper, polyacrylic acid (PAA) was used as a growth modifier to control micron-sized barium sulfate particles via a simple precipitation reaction between sodium sulfate and barium chloride at ambient temperature. The barium sulfate particles were exhibited various morphologies, such as monodisperse spheres, ellipsoids, rose-like aggregates, etc. To better understand the formation mechanisms of the various morphologies of these particles, scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD) and thermo-gravimetric analysis (TGA) were employed. It was found that the PAA concentration, pH, and Ba{sup 2+} and SO{sub 4}{sup 2−} ions concentrations were the most important parameters controlling the morphology of the BaSO{sub 4} particles. These parameters affected the BaSO{sub 4} morphology by influencing the interactions between the PAA carboxyl groups and inorganic ions and the conformation change of the PAA molecular chains. Moreover, this work attempts to provide a preliminary understanding of the formation of the spherical BaSO{sub 4} particles with the randomly coiled conformation of the polymer. - Highlights: • Polyacrylic acid (PAA) was used as a growth modifier to control micron-sized BaSO{sub 4} particles. • The PAA/BaSO{sub 4} particles were exhibited various morphologies. • Provide a preliminary understanding of the formation mechanism of BaSO{sub 4} particles.

  20. Patient dose variation investigated in four Irish hospitals for barium meal and barium enema examinations

    International Nuclear Information System (INIS)

    Carroll, E.; Brennan, P.C.

    2001-01-01

    Four hospitals have been studied, intra- and inter-hospital variations examined and the mean DAP values recorded for barium enemas and barium meals. Mean DAP values for barium meals and barium enemas at 11.4 Gy.cm 2 and 20.1 Gy.cm 2 respectively have been shown. Differences between individual examinations for barium meals varied by up to a factor of 185 and for barium enemas, up to a factor of 19, with hospital means for barium meal and enema examinations each differing by up to a factor of 3. The data provided by this study have suggested that large variations in patient dose do exist in Ireland for barium meal and barium enema examinations. Fluoroscopy time was shown to be a major contributor to the variations reported, with number of images playing a minor role. Results have demonstrated the need for standardisation of technique throughout the country for these examinations. (author)

  1. Thermal decomposition of barium ferrate(VI): Mechanism and formation of FeIV intermediate and nanocrystalline Fe2O3 and ferrite

    International Nuclear Information System (INIS)

    Machala, Libor; Sharma, Virender K.; Kuzmann, Ernö; Homonnay, Zoltán; Filip, Jan; Kralchevska, Radina P.

    2016-01-01

    Simple high-valent iron-oxo species, ferrate(VI) (Fe VI O 4 2− , Fe(VI)) has applications in energy storage, organic synthesis, and water purification. Of the various salts of Fe(VI), barium ferrate(VI) (BaFeO 4 ) has also a great potential as a battery material. This paper presents the thermal decomposition of BaFeO 4 in static air and nitrogen atmosphere, monitored by combination of thermal analysis, Mössbauer spectroscopy, X-ray powder diffraction, and electron-microscopic techniques. The formation of Fe IV species in the form of BaFeO 3 was found to be the primary decomposition product of BaFeO 4 at temperature around 190 °C under both studied atmospheres. BaFeO 3 was unstable in air reacting with CO 2 to form barium carbonate and speromagnetic amorphous iron(III) oxide nanoparticles (<5 nm). Above 600 °C, a solid state reaction between BaCO 3 and Fe 2 O 3 occurred, leading to the formation of barium ferrite nanoparticles, BaFe 2 O 4 (20–100 nm). - Highlights: • We explained the mechanism of thermal decomposition of barium ferrate(VI). • We confirmed the formation of Fe(IV) intermediate phase during the decomposition. • The mechanism of the decomposition is influenced by a presence of carbon dioxide.

  2. Mononuclear non-heme iron(III) complexes of linear and tripodal ...

    Indian Academy of Sciences (India)

    The rate of oxygenation depends on the solvent and the. Lewis acidity of iron(III) ... has been achieved by non-heme iron enzymes and their ..... oxygen atoms of nitrate ion (figure 3). ... enhanced covalency of iron-catecholate interaction and.

  3. Reply to Comments on Measuring marine iron(III) complexes by CLE-AdSV

    NARCIS (Netherlands)

    Town, R.M.; Leeuwen, van H.P.

    2005-01-01

    The interpretation of CLE-AdSV based iron(iii) speciation data for marine waters has been called into question in light of the kinetic features of the measurement. The implications of the re-think may have consequences for understanding iron biogeochemistry and its impact on ecosystem functioning.

  4. Mechanism of oxidation of L-methionine by iron(III)-1,10 ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. Kinetics and mechanism of oxidation of L-methionine by iron(III)–1,10- phenanthroline complex have been studied in perchloric acid medium. The reaction is first order each in iron(III) and methionine. Increase in [phenanthroline] increases the rate while increase in [HClO4] decreases it. While the reactive species ...

  5. Mechanism of oxidation of L-methionine by iron(III)

    Indian Academy of Sciences (India)

    phenanthroline complex have been studied in perchloric acid medium. The reaction is first order each in iron(III) and methionine. Increase in [phenanthroline] increases the rate while increase in [HClO4] decreases it. While the reactive species of the ...

  6. Stabilization through precipitation in a system of colloidal iron(III) pyrophosphate salts

    NARCIS (Netherlands)

    van Leeuwen, Y.M.; Velikov, K.P.; Kegel, W.K.

    2012-01-01

    The ionic strength of a solution decreases during the precipitation of an insoluble salt, which can cause an initially unstable colloidal system to stabilize during its formation. We show this effect in the precipitation and aging of colloidal iron(III) pyrophosphate, where we observe two distinct

  7. Adsorption properties of cationic rhodamine B dye onto metals chloride-activated castor bean residue carbons.

    Science.gov (United States)

    Zhi, Lee Lin; Zaini, Muhammad Abbas Ahmad

    2017-02-01

    This work was aimed to evaluate the feasibility of castor bean residue based activated carbons prepared through metals chloride activation. The activated carbons were characterized for textural properties and surface chemistry, and the adsorption data of rhodamine B were established to investigate the removal performance. Zinc chloride-activated carbon with specific surface area of 395 m 2 /g displayed a higher adsorption capacity of 175 mg/g. Magnesium chloride and iron(III) chloride are less toxic and promising agents for composite chemical activation. The adsorption data obeyed Langmuir isotherm and pseudo-second-order kinetics model. The rate-limiting step in the adsorption of rhodamine B is film diffusion. The positive values of enthalpy and entropy indicate that the adsorption is endothermic and spontaneous at high temperature.

  8. Experimental and Computational Evidence for the Mechanism of Intradiol Catechol Dioxygenation by Non-Heme Iron(III) Complexes

    Science.gov (United States)

    Jastrzebski, Robin; Quesne, Matthew G; Weckhuysen, Bert M; de Visser, Sam P; Bruijnincx, Pieter C A

    2014-01-01

    Catechol intradiol dioxygenation is a unique reaction catalyzed by iron-dependent enzymes and non-heme iron(III) complexes. The mechanism by which these systems activate dioxygen in this important metabolic process remains controversial. Using a combination of kinetic measurements and computational modelling of multiple iron(III) catecholato complexes, we have elucidated the catechol cleavage mechanism and show that oxygen binds the iron center by partial dissociation of the substrate from the iron complex. The iron(III) superoxide complex that is formed subsequently attacks the carbon atom of the substrate by a rate-determining C=O bond formation step. PMID:25322920

  9. Solid solution barium–strontium chlorides with tunable ammonia desorption properties and superior storage capacity

    DEFF Research Database (Denmark)

    Bialy, Agata; Jensen, Peter Bjerre; Blanchard, Didier

    2015-01-01

    with spray drying and in situ thermogravimetric and structural characterization, we synthesize a range of new, stable barium-strontium chloride solid solutions with superior ammonia storage densities. By tuning the barium/strontium ratio, different crystallographic phases and compositions can be obtained...... with different ammonia ab- and desorption properties. In particular it is shown, that in the molar range of 35–50% barium and 65–50% strontium, stable materials can be produced with a practically usable ammonia density (both volumetric and gravimetric) that is higher than any of the pure metal halides...

  10. Barium aspiration and alveolarisation of barium in an infant: A case report and review of management

    Directory of Open Access Journals (Sweden)

    Alan F. Isles

    2014-05-01

    Full Text Available We describe a case of bilateral inhalation and alveolarisation of barium in an infant following a barium swallow for investigation of dusky spells associated with feeds. A bronchoscopy subsequently revealed the presence of a mid-tracheal tracheo-oesophageal cleft. We review the literature on barium aspiration, its consequences and make recommendations for management.

  11. Effects of barium chlorine treatment of uranium ore on 222Rn emanation and 226Ra leachability from mill tailings

    International Nuclear Information System (INIS)

    Ibrahim, S.A.; Church, S.L.; Whicker, F.W.

    1985-01-01

    The purpose of this laboratory study was to investigate the effectiveness of barium chloride treatment of uranium ore on 222 Rn emanation from mill tailings, 226 Ra level in waste-water, and the leachability of radium from tailings. It has been shown that barium sulfate is an excellent carrier for radium and that barium sulfate crystals have high retention capacity for radon gas produced by radium trapped within the lattice. Ground uranium ore from a mine in Wyoming was mixed with water to form a 1:1 ratio before barium and potassium chlorides were added at concentrations of 0, 10, 25, 50, and 100 mg per liter of slurry. The ore was then subjected to a simulated mill process using sulfuric acid leaching. The liquid representing tailings pond water was separated and analyzed for 226 Ra and the solid fraction, representing mill tailings, was tested for radon emanation and the leachability of radium by deionized water. This study suggests that barium treatment of uranium ore prior to sulfuric acid leaching could be effective in reducing radon emanation from tailings and also in reducing the 226 Ra concentration of waste-water. Leachability of radium from treated tailings was markedly reduced

  12. Barium Depletion in Hollow Cathode Emitters

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2009-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the ow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushed back to the emitter surface by the electric field and drag from the xenon ion flow. This barium ion flux is sufficient to maintain a barium surface coverage at the downstream end greater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length, so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollow cathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  13. Multisensor system for determination of iron(II), iron(III) and uranium(VI) in complex solutions

    International Nuclear Information System (INIS)

    Legin, A.V.; Seleznev, B.L.; Rudnitskaya, A.M.; Vlasov, Yu.G.

    1998-01-01

    The aim of the present paper is the development and analytical evaluation of a multisensor system for determination of low content of iron(II), iron(III) and uranium(VI) in complex aqueous media. Sensor array included sensors on the basis of chalcogenide vitreous materials with redox and ionic cross-sensitivities, crystalline silver sulphide electrode, noble metal electrodes Pt, Au, Ag and redox sensor on the basis of oxide glass. Potentiometric measurements have been taken in a conventional electrochemical cell vs. a standard Ag/AgCl reference electrode. All measurements have been taken at room temperature. Calibration solutions contained UO 2 (NO 3 ) 2 in concentration range 10 -6 -1,610 -5 mol/L, K 3 Fe(CN) 6 and K 4 Fe(CN) 6 or FeSO 4 (NH 4 ) 2 SO 4 and FeCl 3 , with the ratio of Fe(II)/Fe(III) concentration from 100:1 to 1:100, the total concentration of Fe was 10 -4 and 10 -5 mol/L. All solutions have been made on the background electrolyte of calcium and magnesium chlorides and sulphates with the fixed content of 5-27 mmol/L of each component which is a typical one for groundwater or mining water. Sensor potentials have been processed by a back-propagation artificial neural net. Average error of determination of Fe(II) and Fe(III) is about 20 %, of uranium(VI) - 40 %. It was found that sensitivity of the sensor array to iron and uranium is irrespective of the chemical form of these species

  14. Dynamical symmetry breaking in barium isotopes

    International Nuclear Information System (INIS)

    Rawat, Bir Singh; Chattopadhyay, P.K.

    1997-01-01

    The isotopes of Xe with mass numbers 124, 126, 128, 130 and the isotopes of barium with mass numbers 128, 130, 132, 134 were shown to correspond to the O(6) dynamical symmetry of IBM. In the investigation of the dynamical symmetry breaking in this region, the barium isotopes for departures from O(6) symmetry have been studied

  15. Laser cooling and trapping of barium

    NARCIS (Netherlands)

    De, Subhadeep

    2008-01-01

    Laser cooling and trapping of heavy alkaline-earth element barium have been demonstrated for the first time ever. For any possible cycling transition in barium that could provide strong cooling forces, the excited state has a very large branching probability to metastable states. Additional lasers

  16. Analysis of barium by isotope mass spectrometry

    International Nuclear Information System (INIS)

    Long Kaiming; Jia Baoting; Liu Xuemei

    2004-01-01

    The isotopic abundance ratios for barium at sub-microgram level are analyzed by thermal surface ionization mass spectrometry (TIMS). Rhenium trips used for sample preparation are firstly treated to eliminate possible barium background interference. During the preparation of barium samples phosphoric acid is added as an emitting and stabilizing reagent. The addition of phosphoric acid increases the collection efficiency and ion current strength and stability for barium. A relative standard deviation of 0.02% for the isotopic abundance ratio of 137 Ba to 138 Ba is achieved when the 138 Ba ion current is (1-3) x 10 -12 A. The experimental results also demonstrate that the isotope fractionation effect is negligibly small in the isotopic analysis of barium

  17. Polyvinyl chloride resin

    International Nuclear Information System (INIS)

    Kim, Hong Jae

    1976-06-01

    This book contains polyvinyl chloride resin industry with present condition such as plastic industry and polyvinyl chloride in the world and Japan, manufacture of polyvinyl chloride resin ; suspension polymerization and solution polymerization, extruding, injection process, hollow molding vinyl record, vacuum forming, polymer powders process, vinyl chloride varnish, vinyl chloride latex, safety and construction on vinyl chloride. Each chapter has descriptions on of process and kinds of polyvinyl chloride resin.

  18. Placement of radium/barium sludges in tailings areas

    International Nuclear Information System (INIS)

    Murphy, K.L.; Multamaki, G.E.

    1980-01-01

    Currently radium is removed from uranium mining and milling effluents by the addition of barium chloride to precipitate the radium as radium/barium sulphate. The precipitate is allowed to settle in sedimentation basins prior to discharge of the effluent. The sedimentation basins are not suitable for final disposal of the sludge, and placement of the sludges in the tailings area has been proposed. The geochemical environment of fresh tailings areas was characterized as an acidic, oxidized surface zone underlain by an alkaline, reduced zone comprising the rest of the tailings. The quantity of sludge produced was estimated to be small relative to the quantity of tailings, and therefor a relatively small amount of radium would be added to the tailings disposal area by the addition of sludge. To confirm whether sludge addition affected radionuclide solubilization, laboratory leaching tests were conducted on slurries of acid leach tailings, and sludge-tailings mixtures. Radium in the (Ra,Ba)SO 4 sludge was at least as stable as radium in the tailings, and the sludge was able to absorb radium released from the tailings. The addition of sludge did not affect uranium and thorium solubilization. From these results it appears that the placement of sludge in tailings areas would not adversely affect the stability of radionuclides in the tailings or sludge. (auth)

  19. Biomimetic oxidation of piperine and piplartine catalyzed by iron(III) and manganese(III) porphyrins.

    Science.gov (United States)

    Schaab, Estela Hanauer; Crotti, Antonio Eduardo Miller; Iamamoto, Yassuko; Kato, Massuo Jorge; Lotufo, Letícia Veras Costa; Lopes, Norberto Peporine

    2010-01-01

    Synthetic metalloporphyrins, in the presence of monooxygen donors, are known to mimetize various reactions of cytochrome P450 enzymes systems in the oxidation of drugs and natural products. The oxidation of piperine and piplartine by iodosylbenzene using iron(III) and manganese(III) porphyrins yielded mono- and dihydroxylated products, respectively. Piplartine showed to be a more reactive substrate towards the catalysts tested. The structures of the oxidation products were proposed based on electrospray ionization tandem mass spectrometry.

  20. Microbial dissimilatory iron(III) reduction: Studies on the mechanism and on processes of environmental relevance

    OpenAIRE

    Jahn, Michael

    2005-01-01

    Many microbes are able to respire aerobically oxygen or anaerobically other electron acceptors for example sulphate, nitrate, manganese(IV) or Fe(III). As iron minerals are widespread in nature, dissimilatory iron(III) reduction by different microorganisms is a very important process of anaerobic respiration. The general goal of this work was to improve the knowledge of processes, in which iron-reducing microbes are said to play an important role. For this purpose, in one part the focus wa...

  1. Ion-Selective Electrode for the Determination of Iron(III in Vitamin Formulations

    Directory of Open Access Journals (Sweden)

    Teixeira Marcos Fernando de S.

    1998-01-01

    Full Text Available A coated graphite-epoxy ion-selective electrode for iron(III, based on the ion-pair formed between [Fe(citrate2]3- and the tricaprylylmethylammonium cation (Aliquat 336 in a poly(vinylchloride (PVC matrix has been constructed. A thin membrane film of this ion-pair, dibutylphthalate (DBPh in PVC was deposited directly onto a Perspex® tube, which contained a graphite-epoxy conductor substrate. The coating solution was prepared by dissolving 30% (w/w of PVC in 10 mL of tetrahydrofuran following addition of 65% (w/w DBPh and 5% (w/w of the ionic pair. The effect of pH, citrate concentration and some cations on the electrode response has been investigated. The E(mV vs. log [Fe(citrate2]3- electrode response was linear for iron(III concentration from 1.0 x 10-3 mol/L to 1.0 x 10-1 mol/L in 1.0 mol/L citrate medium, with a slope of 19.3 ± 0.5 mV/decade and a useful lifetime of at least six months (more than 800 determinations for each polymeric membrane used. The detection limit was 7.5 x 10-4 mol/L and the relative standard deviation was less than 3% for a solution containing 5.0 x 10-3 mol/L of iron(III (n = 10. The application of this electrode for iron(III determination in samples of vitamin formulations is described. The results obtained with this procedure are in close agreement with those obtained using AA spectrophotometry (r = 0.9999.

  2. Disproportionation of hydroxylamine by water-soluble iron(III) porphyrinate compounds.

    Science.gov (United States)

    Bari, Sara E; Amorebieta, Valentín T; Gutiérrez, María M; Olabe, José A; Doctorovich, Fabio

    2010-01-01

    The reactions of hydroxylamine (HA) with several water-soluble iron(III) porphyrinate compounds, namely iron(III) meso-tetrakis-(N-ethylpyridinium-2yl)-porphyrinate ([Fe(III)(TEPyP)](5+)), iron(III) meso-tetrakis-(4-sulphonatophenyl)-porphyrinate ([Fe(III)(TPPS)](3-)), and microperoxidase 11 ([Fe(III)(MP11)]) were studied for different [Fe(III)(Porph)]/[HA] ratios, under anaerobic conditions at neutral pH. Efficient catalytic processes leading to the disproportionation of HA by these iron(III) porphyrinates were evidenced for the first time. As a common feature, only N(2) and N(2)O were found as gaseous, nitrogen-containing oxidation products, while NH(3) was the unique reduced species detected. Different N(2)/N(2)O ratios obtained with these three porphyrinates strongly suggest distinctive mechanistic scenarios: while [Fe(III)(TEPyP)](5+) and [Fe(III)(MP11)] formed unknown steady-state porphyrinic intermediates in the presence of HA, [Fe(III)(TPPS)](3-) led to the well characterized soluble intermediate, [Fe(II)(TPPS)NO](4-). Free-radical formation was only evidenced for [Fe(III)(TEPyP)](5+), as a consequence of a metal centered reduction. We discuss the catalytic pathways of HA disproportionation on the basis of the distribution of gaseous products, free radicals formation, the nature of porphyrinic intermediates, the Fe(II)/Fe(III) redox potential, the coordinating capabilities of each complex, and the kinetic analysis. The absence of NO(2)(-) revealed either that no HAO-like activity was operative under our reaction conditions, or that NO(2)(-), if formed, was consumed in the reaction milieu.

  3. Radiochemical study of the sorption of iodate ions on iron(III) hydroxide precipitate

    International Nuclear Information System (INIS)

    Music, S.; Sipalo-Zuljevic, J.; Wolf, R.H.H.

    1980-01-01

    The sorption of iodate ions on iron(III) hydroxide in dependence on the pH, the aging time of the precipitate and the duration of the contact between the sorbate and the sorbent have been studied. Na 131 IO 3 was used as a radioactive indicator. The sorption mechanism has been discussed in terms of electrostatic and ion-exchange processes at the solid/liquid interface. (author)

  4. The Role of Chloride Ions during the Formation of Akaganéite Revisited

    Directory of Open Access Journals (Sweden)

    Johanna Scheck

    2015-11-01

    Full Text Available Iron(III hydrolysis in the presence of chloride ions yields akaganéite, an iron oxyhydroxide mineral with a tunnel structure stabilized by the inclusion of chloride. Yet, the interactions of this anion with the iron oxyhydroxide precursors occurring during the hydrolysis process, as well as its mechanistic role during the formation of a solid phase are debated. Using a potentiometric titration assay in combination with a chloride ion-selective electrode, we have monitored the binding of chloride ions to nascent iron oxyhydroxides. Our results are consistent with earlier studies reporting that chloride ions bind to early occurring iron complexes. In addition, the data suggests that they are displaced with the onset of oxolation. Chloride ions in the akaganéite structure must be considered as remnants from the early stages of precipitation, as they do not influence the basic mechanism, or the kinetics of the hydrolysis reactions. The structure-directing role of chloride is based upon the early stages of the reaction. The presence of chloride in the tunnel-structure of akagenéite is due to a relatively strong binding to the earliest iron oxyhydroxide precursors, whereas it plays a rather passive role during the later stages of precipitation.

  5. Reactivity of tris(acetylacetonato) iron(III) with tridentate [ONO] donor Schiff base as an access to newer mixed-ligand iron(III) complexes

    Science.gov (United States)

    Bhattacharjee, Chira R.; Goswami, Pankaj; Pramanik, Harun A. R.; Paul, Pradip C.; Mondal, Paritosh

    2011-05-01

    Two new mixed-ligand iron(III) complexes, [Fe(L n)(acac)(C 2H 5OH)] incorporating coordinated ethanol from the reaction solvent were accessed from the reaction of [Fe(acac) 3] with [ONO] donor dibasic tridentate unsymmetrical Schiff base ligands derived from condensation of 2-hydroxy-1-napthaldehyde with 2-aminophenol (H 2L 1) or 2-aminobenzoic acid (H 2L 2). The thermal study (TGA-DTA) provided evidence for weakly bound ethanol which is readily substituted by neutral N-donor molecule imidazole, benzimidazole or pyridine to produce an array of newer complexes, [Fe(L n)(acac)X] ( n = 1, 2; X = Im, Bim, Py). The compounds were characterized by elemental analyses, FT-IR, UV-vis, solution electrical conductivity, FAB mass, 1H and 13C NMR spectroscopy. Room temperature magnetic susceptibility measurements ( μeff ˜ 5.8 B.M.) are consistent with spin-free octahedral iron(III) complexes. Cyclic voltammetry of ethanol complexes revealed a quasi-reversible one electron redox response (Δ Ep > 100 mV) for the Fe(III)/Fe(II) couple. Low half wave redox potential ( E1/2) values suggested easy redox susceptibility. The ground state geometries of the ethanol and imidazole complexes have been ascertained to be distorted octahedral by density functional theory using DMol3 program at BLYP/DNP level.

  6. A new double contrast barium enema

    International Nuclear Information System (INIS)

    Park, Jun Sang; Cho, Won Sik; Lee, Sung Woo; Lee, Mun Gyu; Jeon, Jeong Dong; Jaun, Woo Ki; Han, Chung Yul

    1987-01-01

    A new technic of the barium enema was proposed for the better colonic double contrast study with the average 204ml of 50w/v% barium, applied to 109 serial patients. The barium was introduced to sigmoid colon, and then pushed to a mid transverse colon by the air insufflation through an enema syringe, a new device. An advance to cecum is accomplished by the air insufflation and/or the position change of the patient. The barium transfer method was developed for the best spot film exposure, through colon, by the position change of the patient, the tilting of the x-ray table and the air insufflation with the enema syringe. The mean angle of the x-ray table tilted was -10 .deg. at the beginning the barium enema till the barium sent past the splenic flexure, -15 . deg. for the best lateral view of rectum and -18 .deg. for the bet prone PA view of rectosigmoid colon. This was a simple, better and economic double contrast barium enema for the cooperative patients

  7. Double contrast barium meal and acetylcysteine

    International Nuclear Information System (INIS)

    Kinnunen, J.; Pietilae, J.; Ahovuo, J.; Mankinen, P.; Tervahartiala, P.

    1989-01-01

    In a prospective double blind study, acetylcysteine, a local and systemic respiratory tract mucolytic agent, or a placebo, were given to 100 patients prior to a double contrast barium meal to decrease the gastric mucus viscosity and to make the mucus layer thinner, in order to permit barium to outline the furrows surrounding the areae gastricae instead of the overlying thick mucus. However, acetylcysteine failed to improve either visualization of the areae gastricae or the general quality of the double contrast barium meal. (orig.)

  8. Barium isotope fractionation during experimental formation of the double carbonate BaMn[CO3](2) at ambient temperature.

    Science.gov (United States)

    Böttcher, Michael E; Geprägs, Patrizia; Neubert, Nadja; von Allmen, Katja; Pretet, Chloé; Samankassou, Elias; Nägler, Thomas F

    2012-09-01

    In this study, we present the first experimental results for stable barium (Ba) isotope ((137)Ba/(134)Ba) fractionation during low-temperature formation of the anhydrous double carbonate BaMn[CO(3)](2). This investigation is part of an ongoing work on Ba fractionation in the natural barium cycle. Precipitation at a temperature of 21±1°C leads to an enrichment of the lighter Ba isotope described by an enrichment factor of-0.11±0.06‰ in the double carbonate than in an aqueous barium-manganese(II) chloride/sodium bicarbonate solution, which is within the range of previous reports for synthetic pure BaCO (3) (witherite) formation.

  9. Corrosion of titanium alloys in concentrated chloride solutions at temperature up to 160 deg C

    International Nuclear Information System (INIS)

    Ruskol, Yu.S.; Viter, L.I.; Balakin, A.I.; Fokin, M.N.

    1982-01-01

    Resistance of VT1-0 titanium and 4200, 4207 titanium alloys to pitting and total corrosion in chlorides of cadmium, potassium, nickel, ammonium, barium, calcium, lithium, magnesium in respect to pH value and temperature (120,140,160 deg C) is determined. The results obtained are presented as nomograms of stability. Possible reasons for corrosion behaviour of titanium in each of the chlorides are discussed

  10. Adsorption Characteristics of Different Adsorbents and Iron(III Salt for Removing As(V from Water

    Directory of Open Access Journals (Sweden)

    Josip Ćurko

    2016-01-01

    Full Text Available The aim of this study is to determine the adsorption performance of three types of adsorbents for removal of As(V from water: Bayoxide® E33 (granular iron(III oxide, Titansorb® (granular titanium oxide and a suspension of precipitated iron(III hydroxide. Results of As(V adsorption stoichiometry of two commercial adsorbents and precipitated iron(III hydroxide in tap and demineralized water were fitted to Freundlich and Langmuir adsorption isotherm equations, from which adsorption constants and adsorption capacity were calculated. The separation factor RL for the three adsorbents ranged from 0.04 to 0.61, indicating effective adsorption. Precipitated iron(III hydroxide had the greatest, while Titansorb had the lowest capacity to adsorb As(V. Comparison of adsorption from tap or demineralized water showed that Bayoxide and precipitated iron(III hydroxide had higher adsorption capacity in demineralized water, whereas Titansorb showed a slightly higher capacity in tap water. These results provide mechanistic insights into how commonly used adsorbents remove As(V from water.

  11. Time requirement for barium reduction in intussusception

    International Nuclear Information System (INIS)

    Hwang, Hye Eun; Kim, Seung Ho; Kang, In Young; Park, Byoung Lan; Kim, Byoung Geun

    1988-01-01

    During the period between January 1985 and December 1987, barium reduction was performed in 146 cases of intussusception who were admitted to Kwangju Christian Hospital. The results were as follows: 1. Success rate to the symptom duration is relatively constant. 2. The success rate in infants with severe dehydration was 50% but it was gradually increased in infants with moderate dehydration and in infants with mild dehydration, 83.3% and 100% respectively. 3. The success rate of 12 cases in severely dehydrated infants with positive dissection sign was 16.7%. 4. The success rate of 15 cases in moderately dehydrated infants with positive dissection sign was 66.7%. 5. The average time requirement for barium reduction was 58.3 minutes. No serious complications were noted during barium reduction, except mild vomiting. 6. With above results, it is desirable that barium reduction should be performed according to the patient's physical status and radiologic findings.

  12. Barium Isotopes in Single Presolar Grains

    Science.gov (United States)

    Pellin, M. J.; Davis, A. M.; Savina, M. R.; Kashiv, Y.; Clayton, R. N.; Lewis, R. S.; Amari, S.

    2001-01-01

    Barium isotopic compositions of single presolar grains were measured by laser ablation laser resonant ionization mass spectrometry and the implications of the data for stellar processes are discussed. Additional information is contained in the original extended abstract.

  13. Barium appendicitis after upper gastrointestinal imaging.

    Science.gov (United States)

    Novotny, Nathan M; Lillemoe, Keith D; Falimirski, Mark E

    2010-02-01

    Barium appendicitis (BA) is a rarely seen entity with fewer than 30 reports in the literature. However, it is a known complication of barium imaging. To report a case of BA in a patient whose computed tomography (CT) scan was initially read as foreign body ingestion. An 18-year-old man presented with right lower quadrant pain after upper gastrointestinal imaging 2 weeks prior. A CT scan was obtained of his abdomen and pelvis that revealed a finding that was interpreted as a foreign body at the area of the terminal ileum. A plain X-ray study of the abdomen revealed radiopaque appendicoliths. Pathology confirmed the diagnosis of barium appendicitis. BA is a rare entity and the pathogenesis is unclear. Shorter intervals between barium study and presentation with appendicitis usually correlate with fewer complications. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  14. Neutral barium cloud evolution at different altitudes

    International Nuclear Information System (INIS)

    Li Lei; Xu Ronglan

    2002-01-01

    Considering the joint effects of diffusion, collision, oxidation and photoionization, the authors study the evolution of the barium cloud at different altitudes in the space plasma active experiment. The results present the variation of the loss rate, number density distribution and brightness of the barium cloud over the range from 120 to 260 km. This can be divided into oxidation, oxidation plus photoionization and photoionization regions

  15. Roentgen-phase analysis of sodium chloride of Khodja-Mumindeposit

    International Nuclear Information System (INIS)

    Nazarov, K.M.; Pulatov, M.S.; Isupov, S.D.

    1999-01-01

    With the purpose of determination of mineral composition of sodium chloride by authors was carried out the roentgen-phase analysis till its purification, after filtration and after purification from Ca 2 + , Mg 2 + a nd SO 4 2 + i ons by barium-carbonate and hydrochloride-acid methods

  16. An experimental study on barium peritonitis in rats

    International Nuclear Information System (INIS)

    Kang, Heung Sik; Han, Man Chung; Kim, Chu Wan

    1985-01-01

    Barium sulfate is universally used contrast media in gastrointestinal roentgenology, and spillage of barium into peritoneal cavity can occur. The references on effect of barium sulfate in the peritoneal cavity have been scattered and the results are varied. In 80 rats, body weight of 130 gm to 150 gm, sterile pure barium, sterile commercial barium, intestinal content, and mixed pure barium and intestinal content were experimentally injected into the peritoneal cavity. Consecutive weekly laparotomy and microscopic examination were done for 4 weeks. The results are as followings: 1. Mind inflammatory reaction and mild adhesion after sterile pure barium injection. 2. Mild inflammatory reaction and moderate adhesion after sterile commercial barium injection. 3. Acute peritonitis and abscess formation after intestinal content injection. 4. High mortality due to severe acute peritonitis, and severe adhesion in survivors after injection of both pure barium and intestinal content.

  17. Kinetics of barium sulphate reaction crystallization in crystallizers with internal circulation

    Directory of Open Access Journals (Sweden)

    J. Koralewska

    2008-06-01

    Full Text Available Kinetic calculation results describing the observed nucleation and growth rates of barium sulphate crystals precipitated in an integrated reaction-crystallization process in a barium sulphate-ammonium chloride-water system are presented and analyzed. The scope of experiments included two continuous model DTM-type crystallizers (Draft Tube Magma with internal circulation of the suspension forced by a liquid jet-pump device responsible for stable and intensive enough ascending/descending flow of BaSO4 crystal magma in a mixing chamber. For comparison purposes the experimental data corresponding to a continuous DT (Draft Tube crystallizer with propeller agitator are presented and discussed. The various types of laboratory crystallizers used were fed with concentrated water solution of barium chloride (of 10 or 24 mass % and - in a stoichiometric proportion - crystalline ammonium sulphate, assuming isothermal (348 K and hydrodynamic (average residence time of suspension in a crystallizer: 900 s process conditions. The observed nucleation and growth rates of barium sulphate crystals were estimated on the basis of crystal size distributions (CSDs using convenient calculation scheme derived for an MSMPR (Mixed Suspension Mixed Product Removal model approach. Considering the experimental population density distribution courses, a size-dependent growth (SDG phenomenon was taken into account in the kinetic calculations. Five SDG kinetic models recommended in the accessible literature were used for kinetic parameter values estimation. It was proved statistically, that Rojkowski’s two SDG models (hyperbolic and exponential best suit for our own experimental data description. The experimental data presented can be practically applied for improving the constructions of liquid jet-pump DTM crystallizers recommended for reaction crystallization of sparingly soluble inorganic salts (especially for high concentrations of reaction substrates in the modern

  18. The solvent extraction of zinc, iron, and indium from chloride solutions by neutral organophosphorus compounds

    International Nuclear Information System (INIS)

    Preston, J.S.; Du Preez, A.C.

    1985-01-01

    The preparation of several neutral organophosphorus compounds and their evaluation as selective extractants for zinc in chloride media are described. The compounds belong to the series trialkyl phosphates (RO) 3 PO, dialkyl alkylphosphonates R'PO(OR) 2 , alkyl dialkylphosphinates R 2 'PO(OR), and trialkyl-phosphine oxides R 3 'PO. They were characterized by measurement of their physical properties (melting and boiling points, refractive indices, and densities), and their purities were confirmed by osmometric determination of their molecular masses; by carbon and hydrogen microanalysis; by the titrimetric determination of acidic impurities; and, for liquid products, by comparison of their experimental molar refractivities with empirical values. Metal-distribution equilibria were determined for solutions of the extractants in xylene and aqueous phase containing 0,5 to 5,0 M sodium chloride. Moderately good selectivities were shown for zinc(II) over iron(III), and excellent selectivities were shown for zinc(II) over iron(II), copper(II), lead(II), and cadmium(II). The extraction of indium(III) was similar to that of zinc(II). The extraction of zinc(III), iron(III), and indium(III) increased markedly through the series. (RO) 3 PO 2 2 'PO(OR) 3 'PO. The incorporation of phenyl groups into the compounds led to weaker extraction. The extracted complexes of zinc(II), iron(III), and indium(III) have the stoichiometries ZnCl 2 L 2 ,FeCl 3 L 2 (H 2 O), and InCl 3 L 2 (H 2 O) respectively, where L represents the neutral organophosphorus compound

  19. Different arsenate and phosphate incorporation effects on the nucleation and growth of iron(III) (Hydr)oxides on quartz.

    Science.gov (United States)

    Neil, Chelsea W; Lee, Byeongdu; Jun, Young-Shin

    2014-10-21

    Iron(III) (hydr)oxides play an important role in the geochemical cycling of contaminants in natural and engineered aquatic systems. The ability of iron(III) (hydr)oxides to immobilize contaminants can be related to whether the precipitates form heterogeneously (e.g., at mineral surfaces) or homogeneously in solution. Utilizing grazing incidence small-angle X-ray scattering (GISAXS), we studied heterogeneous iron(III) (hydr)oxide nucleation and growth on quartz substrates for systems containing arsenate and phosphate anions. For the iron(III) only system, the radius of gyration (Rg) of heterogeneously formed precipitates grew from 1.5 to 2.5 (± 1.0) nm within 1 h. For the system containing 10(-5) M arsenate, Rg grew from 3.6 to 6.1 (± 0.5) nm, and for the system containing 10(-5) M phosphate, Rg grew from 2.0 to 4.0 (± 0.2) nm. While the systems containing these oxyanions had more growth, the system containing only iron(III) had the most nucleation events on substrates. Ex situ analyses of homogeneously and heterogeneously formed precipitates indicated that precipitates in the arsenate system had the highest water content and that oxyanions may bridge iron(III) hydroxide polymeric embryos to form a structure similar to ferric arsenate or ferric phosphate. These new findings are important because differences in nucleation and growth rates and particle sizes will impact the number of available reactive sites and the reactivity of newly formed particles toward aqueous contaminants.

  20. Spectral K-edge subtraction imaging of experimental non-radioactive barium uptake in bone.

    Science.gov (United States)

    Panahifar, Arash; Samadi, Nazanin; Swanston, Treena M; Chapman, L Dean; Cooper, David M L

    2016-12-01

    To evaluate the feasibility of using non-radioactive barium as a bone tracer for detection with synchrotron spectral K-edge subtraction (SKES) technique. Male rats of 1-month old (i.e., developing skeleton) and 8-month old (i.e., skeletally mature) were orally dosed with low dose of barium chloride (33mg/kg/day Ba 2+ ) for 4weeks. The fore and hind limbs were dissected for imaging in projection and computed tomography modes at 100μm and 52μm pixel sizes. The SKES method utilizes a single bent Laue monochromator to prepare a 550eV energy spectrum to encompass the K-edge of barium (37.441keV), for collecting both 'above' and 'below' the K-edge data sets in a single scan. The SKES has a very good focal size, thus limits the 'crossover' and motion artifacts. In juvenile rats, barium was mostly incorporated in the areas of high bone turnover such as at the growth plate and the trabecular surfaces, but also in the cortical bone as the animals were growing at the time of tracer administration. However, the adults incorporated approximately half the concentration and mainly in the areas where bone remodeling was predominant and occasionally in the periosteal and endosteal layers of the diaphyseal cortical bone. The presented methodology is simple to implement and provides both structural and functional information, after labeling with barium, on bone micro-architecture and thus has great potential for in vivo imaging of pre-clinical animal models of musculoskeletal diseases to better understand their mechanisms and to evaluate the efficacy of pharmaceuticals. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Sulphate removal from sodium sulphate-rich brine and recovery of barium as a barium salt mixture.

    Science.gov (United States)

    Vadapalli, Viswanath R K; Zvimba, John N; Mulopo, Jean; Motaung, Solly

    2013-01-01

    Sulphate removal from sodium sulphate-rich brine using barium hydroxide and recovery of the barium salts has been investigated. The sodium sulphate-rich brine treated with different dosages of barium hydroxide to precipitate barium sulphate showed sulphate removal from 13.5 g/L to less than 400 mg/L over 60 min using a barium to sulphate molar ratio of 1.1. The thermal conversion of precipitated barium sulphate to barium sulphide achieved a conversion yield of 85% using coal as both a reducing agent and an energy source. The recovery of a pure mixture of barium salts from barium sulphide, which involved dissolution of barium sulphide and reaction with ammonium hydroxide resulted in recovery of a mixture of barium carbonate (62%) and barium hydroxide (38%), which is a critical input raw material for barium salts based acid mine drainage (AMD) desalination technologies. Under alkaline conditions of this barium salt mixture recovery process, ammonia gas is given off, while hydrogen sulfide is retained in solution as bisulfide species, and this provides basis for ammonium hydroxide separation and recovery for reuse, with hydrogen sulfide also recoverable for further industrial applications such as sulfur production by subsequent stripping.

  2. Synthesis of barium mercaptides and application of antimony/barium mercaptides

    Institute of Scientific and Technical Information of China (English)

    瞿龙; 张露露; 舒万艮

    2001-01-01

    Mercaptoacetic acid, isooctyl thioglycolate and barium hydroxide used as start materials, barium bis (2-ethylhexyl thioglycolate) (Ba(2EHTG)2), barium thioglycolate (Ba(TG)) and barium bisthioglycolate (Ba(TG)2) were synthesized. Their optimum synthetic techniques were discussed, and some physicochemical data were reported. Infrared spectroscopy and elemental analysis methods were used to identify the structures. They were put into PVC plastic products together with antimony tris (2-ethylhexyl thioglycolate) (Sb(2EHTG)3) under the suitable compounding, and their heat stability to PVC was studied. It is shown that these barium mercaptides have remarkable synergisms with antimony mercaptides and the long-term stabilizing effect of organoantimony stabilizer can be effectively improved, reducing the amount of antimony compounds so as to avoid the decrease of its stabilizing effect.

  3. Thermal decomposition of barium ferrate(VI): Mechanism and formation of Fe{sup IV} intermediate and nanocrystalline Fe{sub 2}O{sub 3} and ferrite

    Energy Technology Data Exchange (ETDEWEB)

    Machala, Libor, E-mail: libor.machala@upol.cz [Regional Centre of Advanced Technologies and Materials, Department of Experimental Physics, Faculty of Science, Palacký University, Olomouc (Czech Republic); Sharma, Virender K. [Department of Environmental and Occupational Health, School of Public Health, Texas A& M University, 1266 TAMU, College Station, TX 77843 (United States); Kuzmann, Ernö; Homonnay, Zoltán [Institute of Chemistry, Eötvös Loránd University, Budapest (Hungary); Filip, Jan; Kralchevska, Radina P. [Regional Centre of Advanced Technologies and Materials, Department of Experimental Physics, Faculty of Science, Palacký University, Olomouc (Czech Republic)

    2016-05-25

    Simple high-valent iron-oxo species, ferrate(VI) (Fe{sup VI}O{sub 4}{sup 2−}, Fe(VI)) has applications in energy storage, organic synthesis, and water purification. Of the various salts of Fe(VI), barium ferrate(VI) (BaFeO{sub 4}) has also a great potential as a battery material. This paper presents the thermal decomposition of BaFeO{sub 4} in static air and nitrogen atmosphere, monitored by combination of thermal analysis, Mössbauer spectroscopy, X-ray powder diffraction, and electron-microscopic techniques. The formation of Fe{sup IV} species in the form of BaFeO{sub 3} was found to be the primary decomposition product of BaFeO{sub 4} at temperature around 190 °C under both studied atmospheres. BaFeO{sub 3} was unstable in air reacting with CO{sub 2} to form barium carbonate and speromagnetic amorphous iron(III) oxide nanoparticles (<5 nm). Above 600 °C, a solid state reaction between BaCO{sub 3} and Fe{sub 2}O{sub 3} occurred, leading to the formation of barium ferrite nanoparticles, BaFe{sub 2}O{sub 4} (20–100 nm). - Highlights: • We explained the mechanism of thermal decomposition of barium ferrate(VI). • We confirmed the formation of Fe(IV) intermediate phase during the decomposition. • The mechanism of the decomposition is influenced by a presence of carbon dioxide.

  4. Structure and Magnetic Properties of a Dodecanuclear Twisted-Ring Iron(III) Cluster.

    Science.gov (United States)

    Caneschi, Andrea; Cornia, Andrea; Fabretti, Antonio C; Gatteschi, Dante

    1999-05-03

    An unprecedented nonplanar structure characterizes the complex [Fe(OCH 3 ) 2 (dbm)] 12 (on the left in the picture), which contains the largest cyclic ferric cluster yet reported with chemically equivalent bridging units. It is made up of twelve high-spin, antiferromagnetically coupled iron(III) centers and neatly reacts with Na I or Li I templates in organic solution to give hexairon(III) coronates (right). Fe=•, O=○, NaI or LiI=• Hdbm=dibenzoylmethane. © 1999 WILEY-VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany.

  5. Sorption of microamount of colloidal silver iodide on hydrated iron(III) oxide

    International Nuclear Information System (INIS)

    Kepak, F.; Nova, J.

    1975-01-01

    Sorption of a microamount of colloidal silver iodide labelled with 131 I on hydrated iron/III/ oxide suspension was studied. The sorption dependence upon pH, sorbent amount, and inert electrolyte concentration has revealed that sorption of silver iodide reaches no more than 63%. The sorption lasted one hour during which the maximum value was reached. Desorption time was one hour, as well. Except for measuring the sorption dependence on pH, the sorption pH was 7.0, temperature 24+-2 0 C. (F.G.)

  6. Experimental and Computational Evidence for the Mechanism of Intradiol Catechol Dioxygenation by Non- Heme Iron(III) Complexes

    NARCIS (Netherlands)

    Jastrzebski, Robin; Quesne, Matthew G.; Weckhuysen, Bert M.; de Visser, Sam P.; Bruijnincx, Pieter C. A.

    2014-01-01

    Catechol intradiol dioxygenation is a unique reaction catalyzed by iron-dependent enzymes and nonheme iron(III) complexes. The mechanism by which these systems activate dioxygen in this important metabolic process remains controversial. Using a combination of kinetic measurements and computational

  7. Coprecipitation of iron and silver with barium fluoride

    International Nuclear Information System (INIS)

    Kopilova, N.V.; Khamidov, B.O.; Kashina, Z.A.; Ikrami, D.D.

    1986-01-01

    Distribution of trace contaminants of iron and silver at coprecipitation of barium fluoride is studied in present work. It is defined that iron almost completely coprecipitated with barium fluoride in wide range of ph 5.5-12. Silver coprecipitated with barium fluoride in ph range 4-7. The value of coprecipitation varies from 94% to 100%.

  8. 40 CFR 721.10011 - Barium calcium manganese strontium oxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium calcium manganese strontium... Specific Chemical Substances § 721.10011 Barium calcium manganese strontium oxide. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium calcium...

  9. Barium ion beam. Annual progress report

    International Nuclear Information System (INIS)

    Lazar, N.; Dandl, R.; Rynn, N.; Wickham, M.

    1985-01-01

    The barium ion beam Zeeman diagnostic is an in situ nonperturbing diagnostic designed to measure both the plasma electric and magnetic fields in devices such as STM and EBT. The diagnostic satisfies the requirements of high precision, spatial resolution and nonperturbation of the plasma. The technique uses resonance absorption of light from a single moded laser in a beam of energetic barium ions to measure the Zeeman effect in the absorption spectrum (to measure changes in the magnetic field) and to observe the changes in beam velocity by the Doppler shift of the absorption lines

  10. Printed Barium Strontium Titanate capacitors on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Sette, Daniele [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg); Kovacova, Veronika [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Defay, Emmanuel, E-mail: emmanuel.defay@list.lu [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Luxembourg Institute of Science and Technology LIST, Materials Research and Technology Department, L-4422 Belvaux (Luxembourg)

    2015-08-31

    In this paper, we show that Barium Strontium Titanate (BST) films can be prepared by inkjet printing of sol–gel precursors on platinized silicon substrate. Moreover, a functional variable capacitor working in the GHz range has been made without any lithography or etching steps. Finally, this technology requires 40 times less precursors than the standard sol–gel spin-coating technique. - Highlights: • Inkjet printing of Barium Strontium Titanate films • Deposition on silicon substrate • Inkjet printed silver top electrode • First ever BST films thinner than 1 μm RF functional variable capacitor that has required no lithography.

  11. Chloride test - blood

    Science.gov (United States)

    Serum chloride test ... A greater-than-normal level of chloride is called hyperchloremia. It may be due to: Carbonic anhydrase inhibitors (used to treat glaucoma) Diarrhea Metabolic acidosis Respiratory alkalosis (compensated) Renal ...

  12. Chloride in diet

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002417.htm Chloride in diet To use the sharing features on this page, please enable JavaScript. Chloride is found in many chemicals and other substances ...

  13. Mercuric chloride poisoning

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/002474.htm Mercuric chloride poisoning To use the sharing features on this page, please enable JavaScript. Mercuric chloride is a very poisonous form of mercury. It ...

  14. Effect of alkaline earth metal and magnesium cations on cadmium extraction from chloride solutions by tributyl phosphate

    International Nuclear Information System (INIS)

    Prokuev, V.A.; Belousov, E.A.

    1985-01-01

    At 298 K thermodynamic constants of cadmium (2) extraction from chloride solutions of magnesium, calcium, strontium and barium by tributyl phosphate are calculated. It is established, that logarithm of the thermodynamic extraction constant is in a linear dependence from the change in the cation hydration enthalpy in agqueous solution. It is shown, that activity coefficient of neutral complex CdVCl 2 differs from one, and it is the higher the more stable the complex is in alkaline earth metal chloride solutions

  15. Effect of sodium bicarbonate pretreatment on barium coating of mucosa during double contrast barium meal

    International Nuclear Information System (INIS)

    Kinnunen, J.; Toetterman, S.; Kaila, R.; Pietilae, J.; Linden, H.; Tervahartiala, P.

    1983-01-01

    The radiographic pattern of the areae gastricae is produced by barium lying in the intersecting furrows of the gastric mucosal surface. However, if the mucus layer on the gastric mucosa is thick, it interferes with the barium coating of the areae gastricae during double contrast barium meal. As sodium bicarbonate decreases the viscosity of mucus and thus may make the gastric mucus layer thinner, it was evaluated as a pretreatment agent in a routine double contrast upper-gastrointestinal study to improve the visualization of the areae gastricae. In a single blind study, 53 of 106 patients took sodium bicarbonate water mixtures at bedtime the day before and on the morning of the examination. According to the results of the present study mucolysis induced by the used doses of sodium bicarbonate does not significantly affect micromucosal visualization during double-contrast barium meal. (orig.) [de

  16. Effect of sodium bicarbonate pretreatment on barium coating of mucosa during double contrast barium meal

    Energy Technology Data Exchange (ETDEWEB)

    Kinnunen, J.; Toetterman, S.; Kaila, R.; Pietilae, J.; Linden, H.; Tervahartiala, P.

    1983-08-01

    The radiographic pattern of the areae gastricae is produced by barium lying in the intersecting furrows of the gastric mucosal surface. However, if the mucus layer on the gastric mucosa is thick, it interferes with the barium coating of the areae gastricae during double contrast barium meal. As sodium bicarbonate decreases the viscosity of mucus and thus may make the gastric mucus layer thinner, it was evaluated as a pretreatment agent in a routine double contrast upper-gastrointestinal study to improve the visualization of the areae gastricae. In a single blind study, 53 of 106 patients took sodium bicarbonate water mixtures at bedtime the day before and on the morning of the examination. According to the results of the present study mucolysis induced by the used doses of sodium bicarbonate does not significantly affect micromucosal visualization during double-contrast barium meal.

  17. Enterogastroesophageal reflux during barium enema: Report of a case

    International Nuclear Information System (INIS)

    Shin, Hyoun Ja; Rhee, Hak Song

    1972-01-01

    Enterogastric reflux during barium enema examination has been ascribed to various causes including incompetence of the ilepcecal valve, shunt, fistula, excessive barium etc. Recently we have encountered a case of complete enterogastroesphageal regurgitation during barium enema examination performed for the reduction of the ileocolic intuosusception in 6 months old baby. The regurgitation occurred only in the first of two barium enema examinations conducted at one month interval for recurring intussusception. The barium-saline solution used in the present study was not more than 350 ml in quantity. No organic or physical causes of such a complete regurgitation could be determined

  18. Blood pressure changes during barium enema

    International Nuclear Information System (INIS)

    Roach, S.C.; Martin, O.J.D.; Owen, A.; Martin, D.F.

    2001-01-01

    AIMS: To document blood pressure changes during barium enema examination and to determine at what point in the examination changes are likely to occur. METHODS AND RESULTS: Blood pressure measurements were taken at seven points during the course of barium enema examination in 107 consecutive patients. We found that patients over the age of 60 years had statistically significant decreases in blood pressure when they were stood up during the course of the examination. Many of these patients were asymptomatic. Patients who had symptoms (15/107, 14%) when standing up had a degree of hypotension. The duration of barium enema examination is longer in those patients who experience symptoms. CONCLUSION: During a barium enema examination hypotension occurs at the point of standing up more frequently in patients over 60 years and in those who suffer symptoms at this time. Patients who fall into one of these groups should be considered at risk of fainting at this point in the examination. A modified technique to avoid standing should be considered in at-risk patients. Roach, S.C. et al. (2001)

  19. High temperature impedance spectroscopy of barium stannate ...

    Indian Academy of Sciences (India)

    (M = Ba, Sr, Ca and Pb). ... Barium stannate (BaSnO3) is a cubic pervoskite oxide com- .... were gold-sputtered and scanned in different regions using .... de ions. Water insertion into the oxide structure can be re- presented as the process of ...

  20. Thermal decomposition of barium valerate in argon

    DEFF Research Database (Denmark)

    Torres, P.; Norby, Poul; Grivel, Jean-Claude

    2015-01-01

    The thermal decomposition of barium valerate (Ba(C4H9CO2)(2)/Ba-pentanoate) was studied in argon by means of thermogravimetry, differential thermal analysis, IR-spectroscopy, X-ray diffraction and hot-stage optical microscopy. Melting takes place in two different steps, at 200 degrees C and 280...

  1. Rheological properties of potassium barium borate glasses

    NARCIS (Netherlands)

    Szwejda, K.A.; Vogel, D.L.; Stevels, J.M.

    1973-01-01

    Several series of potassium barium borate glasses have been investigated as to their rheological properties. It has been found, that all these glasses show deviations from ‘Newtonian’ behaviour below temperatures corresponding to viscosities of 1010 poises. The activation energies of viscous flow

  2. Impurities in barium titanate posistor ceramics

    Czech Academy of Sciences Publication Activity Database

    Korniyenko, S. M.; Bykov, I. P.; Glinchuk, M. J.; Laguta, V. V.; Belous, A. G.; Jastrabík, Lubomír

    2000-01-01

    Roč. 239, - (2000), s. 1209-1218 ISSN 0015-0193 Institutional research plan: CEZ:AV0Z1010914 Keywords : barium titanate phase transition * ESR * positive temperature coefficient of resistivity Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.547, year: 2000

  3. Novel spin transition between S = 5/2 and S = 3/2 in highly saddled iron(III) porphyrin complexes at extremely low temperatures.

    Science.gov (United States)

    Ohgo, Yoshiki; Chiba, Yuya; Hashizume, Daisuke; Uekusa, Hidehiro; Ozeki, Tomoji; Nakamura, Mikio

    2006-05-14

    A novel spin transition between S = 5/2 and S = 3/2 has been observed for the first time in five-coordinate, highly saddled iron(III) porphyrinates by EPR and SQUID measurements at extremely low temperatures.

  4. Complexation equilibria and spectrophotometric determination of iron(III) with 1-amino-4-hydroxyanthraquinone.

    Science.gov (United States)

    Abu-Bakr, M S; Sedaira, H; Hashem, E Y

    1994-10-01

    The complex equilibria of iron(III) with 1-amino-4-hydroxyanthraquinone (AMHA) were studied spectrophotometrically in 40% (v/v) ethanol and an ionic strength of 0.1M (NaClO(4)). The complexation reactions were demonstrated and characterized using graphical logarithmic analysis of the absorbance-pH graphs. A simple, rapid, selective and sensitive method for the spectrophotometric determination of trace amounts of Fe(III) is developed based on the formation of Fe(AMHA) complex at pH 2.5 (lambda(max) = 640 nm, epsilon approximately = 2.1 x 10(4) L. mol(-1) . cm(-1)) in the presence of a large number of foreign ions. Interferences caused by palladium(II) was masked by the addition of cyanide ions. The method has been applied to the determination of iron in some synthetic samples and polymetallic iron ores.

  5. The preparation of magnetite from iron(III) and iron(II) salt solutions

    International Nuclear Information System (INIS)

    Segal, D.L.

    1980-10-01

    Methods are described for the preparation of magnetite from iron(III) and iron(II) salt solutions at temperatures between 295 to 373 K. The effect of the reagent concentration, a chelating agent and different alkali-metal cations on the formation of magnetite has been investigated. The magnetite samples have been examined by X-ray diffraction, transmission electron microscopy, adsorption of nitrogen, emission spectroscopy, X-ray photoelectron spectroscopy and by determination of the point of zero charge. A review of previous work on the preparation of magnetite in an aqueous environment is also included. This work is relevant to the corrosion processes which can occur in the water coolant circuits of nuclear reactors. (author)

  6. N-butylamine functionalized graphene oxide for detection of iron(III) by photoluminescence quenching.

    Science.gov (United States)

    Gholami, Javad; Manteghian, Mehrdad; Badiei, Alireza; Ueda, Hiroshi; Javanbakht, Mehran

    2016-02-01

    An N-butylamine functionalized graphene oxide nanolayer was synthesized and characterized by ultraviolet (UV)-visible spectrometry, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and transmission electron microscopy. Detection of iron(III) based on photoluminescence spectroscopy was investigated. The N-butylamine functionalized graphene oxide was shown to specifically interact with iron (III), compared with other cationic trace elements including potassium (I), sodium (I), calcium (II), chromium (III), zinc (II), cobalt (II), copper (II), magnesium (II), manganese (II), and molybdenum (VI). The quenching effect of iron (III) on the luminescence emission of N-butylamine functionalized graphene oxide layer was used to detect iron (III). The limit of detection (2.8 × 10(-6)  M) and limit of quantitation (2.9 × 10(-5)  M) were obtained under optimal conditions. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Barium carbonate as an agent to improve the electrical properties of neodymium-barium-copper system at high temperature

    International Nuclear Information System (INIS)

    Fernandes, J.P.; Duarte, G.W.; Caldart, C.; Kniess, C.T.; Montedo, O.R.K.; Rocha, M.R.; Riella, H.G.; Fiori, M.A.

    2015-01-01

    Specialized ceramics are manufactured under special conditions and contain specific elements. They possess unique electrical and thermal properties and are frequently used by the electronics industry. Ceramics containing neodymium-barium-copper (NBC) exhibit high conductivities at low temperatures. NBC-based ceramics are typically combined with oxides, i.e., NBCo produced from neodymium oxide, barium oxide and copper oxide. This study presents NBC ceramics that were produced with barium carbonate, copper oxide and neodymium oxide (NBCa) as starting materials. These ceramics have good electrical conductivities at room temperature. Their conductivities are temperature dependent and related to the starting amount of barium carbonate (w%). - Highlights: • The new crystalline structure were obtained due presence of the barium carbonate. • The NBCa compound has excellent electrical conductivity at room temperature. • The grain crystalline morphology was modified by presence of the barium carbonate. • New Phases α and β were introduced by carbonate barium in the NBC compound

  8. Barium carbonate as an agent to improve the electrical properties of neodymium-barium-copper system at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, J.P. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Duarte, G.W. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Research Group in Technology and Information, Centro Universitário Barriga Verde (UNIBAVE), Santa Catarina, SC (Brazil); Caldart, C. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Kniess, C.T. [Post-Graduate Program in Professional Master in Management, Universidade Nove de Julho, São Paulo, SP (Brazil); Montedo, O.R.K.; Rocha, M.R. [Post-Graduate Program in Science and Materials Engineering, Universidade do Extremo Sul Catarinense (UNESC), Criciúma, SC, 88806-000 (Brazil); Riella, H.G. [Post-Graduate Program in Chemical Engineering, Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC, 88040-900 (Brazil); Fiori, M.A., E-mail: fiori@unochapeco.edu.br [Post-Graduate Program in Environmental Science, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil); Post-Graduate Program in Technology and Management of the Innovation, Universidade Comunitária da Região de Chapecó (UNOCHAPECÓ), Chapecó, SC, 89809-000 (Brazil)

    2015-11-15

    Specialized ceramics are manufactured under special conditions and contain specific elements. They possess unique electrical and thermal properties and are frequently used by the electronics industry. Ceramics containing neodymium-barium-copper (NBC) exhibit high conductivities at low temperatures. NBC-based ceramics are typically combined with oxides, i.e., NBCo produced from neodymium oxide, barium oxide and copper oxide. This study presents NBC ceramics that were produced with barium carbonate, copper oxide and neodymium oxide (NBCa) as starting materials. These ceramics have good electrical conductivities at room temperature. Their conductivities are temperature dependent and related to the starting amount of barium carbonate (w%). - Highlights: • The new crystalline structure were obtained due presence of the barium carbonate. • The NBCa compound has excellent electrical conductivity at room temperature. • The grain crystalline morphology was modified by presence of the barium carbonate. • New Phases α and β were introduced by carbonate barium in the NBC compound.

  9. Isolation of microorganisms involved in reduction of crystalline iron(III) oxides in natural environments.

    Science.gov (United States)

    Hori, Tomoyuki; Aoyagi, Tomo; Itoh, Hideomi; Narihiro, Takashi; Oikawa, Azusa; Suzuki, Kiyofumi; Ogata, Atsushi; Friedrich, Michael W; Conrad, Ralf; Kamagata, Yoichi

    2015-01-01

    Reduction of crystalline Fe(III) oxides is one of the most important electron sinks for organic compound oxidation in natural environments. Yet the limited number of isolates makes it difficult to understand the physiology and ecological impact of the microorganisms involved. Here, two-stage cultivation was implemented to selectively enrich and isolate crystalline iron(III) oxide reducing microorganisms in soils and sediments. Firstly, iron reducers were enriched and other untargeted eutrophs were depleted by 2-years successive culture on a crystalline ferric iron oxide (i.e., goethite, lepidocrocite, hematite, or magnetite) as electron acceptor. Fifty-eight out of 136 incubation conditions allowed the continued existence of microorganisms as confirmed by PCR amplification. High-throughput Illumina sequencing and clone library analysis based on 16S rRNA genes revealed that the enrichment cultures on each of the ferric iron oxides contained bacteria belonging to the Deltaproteobacteria (mainly Geobacteraceae), followed by Firmicutes and Chloroflexi, which also comprised most of the operational taxonomic units (OTUs) identified. Venn diagrams indicated that the core OTUs enriched with all of the iron oxides were dominant in the Geobacteraceae while each type of iron oxides supplemented selectively enriched specific OTUs in the other phylogenetic groups. Secondly, 38 enrichment cultures including novel microorganisms were transferred to soluble-iron(III) containing media in order to stimulate the proliferation of the enriched iron reducers. Through extinction dilution-culture and single colony isolation, six strains within the Deltaproteobacteria were finally obtained; five strains belonged to the genus Geobacter and one strain to Pelobacter. The 16S rRNA genes of these isolates were 94.8-98.1% identical in sequence to cultured relatives. All the isolates were able to grow on acetate and ferric iron but their physiological characteristics differed considerably in

  10. Reconstruction of Extracellular Respiratory Pathways for Iron(III Reduction in Shewanella oneidensis strain MR-1

    Directory of Open Access Journals (Sweden)

    Dan eCoursolle

    2012-02-01

    Full Text Available Shewanella oneidensis strain MR-1 is a facultative anaerobic bacterium capable of respiring a multitude of electron acceptors, many of which require the Mtr respiratory pathway. The core Mtr respiratory pathway includes a periplasmic c-type cytochrome (MtrA, an integral outer membrane β-barrel protein (MtrB and an outer membrane-anchored c-type cytochrome (MtrC. Together, these components facilitate transfer of electrons from the c-type cytochrome CymA in the cytoplasmic membrane to electron acceptors at and beyond the outer membrane. The genes encoding these core proteins have paralogs in the S. oneidensis genome (mtrB and mtrA each have four while mtrC has three and some of the paralogs of mtrC and mtrA are able to form functional Mtr complexes. We demonstrate that of the additional three mtrB paralogs found in the S. oneidensis genome, only MtrE can replace MtrB to form a functional respiratory pathway to soluble iron(III citrate. We also evaluate which mtrC / mtrA paralog pairs (a total of 12 combinations are able to form functional complexes with endogenous levels of mtrB paralog expression. Finally, we reconstruct all possible functional Mtr complexes and test them in a S. oneidensis mutant strain where all paralogs have been eliminated from the genome. We find that each combination tested with the exception of MtrA / MtrE / OmcA is able to reduce iron(III citrate at a level significantly above background. The results presented here have implications towards the evolution of anaerobic extracellular respiration in Shewanella and for future studies looking to increase the rates of substrate reduction for water treatment, bioremediation, or electricity production.

  11. Oesophageal motility disorders - diagnosis with a barium-rice study

    International Nuclear Information System (INIS)

    Schwickert, H.C.; Schadmand-Fischer, S.; Klose, P.; Staritz, M.; Ueberschaer, B.; Thelen, M.

    1993-01-01

    The purpose of this study was to evaluate the role of a 'barium-rice' study for diagnosis of dysphagia and oesophageal motility disorders. Material and methods: 203 patients with oesophageal motility disorders of various aetiologies were examined by both conventional barium study and a 'barium-rice' study. During the latter, oesophageal clearance of a defined mixture of barium sulfate and boiled rice was measured. Results: The conventional barium study revealed prolonged transit time in only 15.8% (32 of 203 cases), whereas barium-rice study was pathological in 50.8% (103 of 203 cases). In 71 of 171 patients (41.5%) with a normal barium study, barium-rice passage was prolonged. In 23 patients, radiological results were confirmed by manometric measurements. Conclusion: Oesophageal motility disorders are detected by a barim-rice study with high sensitivity independent of the underlying disease. The barium-rice study offers a simple diagnostic tool revealing quantitative and reliable results. The barium-rice study is a suitable method for screening and follow-up of patients with dysphagia and oesophageal motility disorders. (orig.) [de

  12. Radioactive Barium Ion Trap Based on Metal-Organic Framework for Efficient and Irreversible Removal of Barium from Nuclear Wastewater.

    Science.gov (United States)

    Peng, Yaguang; Huang, Hongliang; Liu, Dahuan; Zhong, Chongli

    2016-04-06

    Highly efficient and irreversible capture of radioactive barium from aqueous media remains a serious task for nuclear waste disposal and environmental protection. To address this task, here we propose a concept of barium ion trap based on metal-organic framework (MOF) with a strong barium-chelating group (sulfate and sulfonic acid group) in the pore structures of MOFs. The functionalized MOF-based ion traps can remove >90% of the barium within the first 5 min, and the removal efficiency reaches 99% after equilibrium. Remarkably, the sulfate-group-functionalized ion trap demonstrates a high barium uptake capacity of 131.1 mg g(-1), which surpasses most of the reported sorbents and can selectively capture barium from nuclear wastewater, whereas the sulfonic-acid-group-functionalized ion trap exhibits ultrafast kinetics with a kinetic rate constant k2 of 27.77 g mg(-1) min(-1), which is 1-3 orders of magnitude higher than existing sorbents. Both of the two MOF-based ion traps can capture barium irreversibly. Our work proposes a new strategy to design barium adsorbent materials and provides a new perspective for removing radioactive barium and other radionuclides from nuclear wastewater for environment remediation. Besides, the concrete mechanisms of barium-sorbent interactions are also demonstrated in this contribution.

  13. Determination of silver in fresh water by atomic absorption spectrometry following flotation preconcentration by iron(III) collectors

    Energy Technology Data Exchange (ETDEWEB)

    Cundeva, K.; Stafilov, T. [Institute of Chemistry, Faculty of Science, St. Cyril and Methodius University, Skopje (Yugoslavia)

    1997-08-01

    Colloid precipitate flotation of silver from fresh water is applied for preconcentration and separation. Optimal conditions using hydrated iron(III) oxide and iron(III) tetramethylenedithiocarbamate as collectors were investigated. Various factors affecting the silver recovery, including collector mass, nature of the supporting electrolyte, pH of the working medium, electrokinetic potential of the collector particle surfaces, type of surfactant, induction time etc., were checked. Within the optimal pH range (5.5-6.5) silver was separated quantitatively (94.9- 100.0%) with 30 mg Fe(III) as collector. The content of silver was determined by electrothermal atomic absorption spectrometry and compared to that from inductively coupled plasma-atomic emission spectrometry. The detection limit of silver by the method described is 0.01 {mu}g/L. (orig.) With 2 figs., 3 tabs.

  14. Iron(iii) bis(pyrazol-1-yl)acetate based decanuclear metallacycles: synthesis, structure, magnetic properties and DFT calculations.

    Science.gov (United States)

    Gajewska, Małgorzata J; Bieńko, Alina; Herchel, Radovan; Haukka, Matti; Jerzykiewicz, Maria; Ożarowski, Andrzej; Drabent, Krzysztof; Hung, Chen-Hsiung

    2016-09-27

    The synthesis, structural aspects, magnetic interpretation and theoretical rationalizations for a new member of the ferric wheel family, a decanuclear iron(iii) complex with the formula [Fe 10 (bdtbpza) 10 (μ 2 -OCH 3 ) 20 ] (1), featuring the N,N,O tridentate bis(3,5-di-tert-butylpyrazol-1-yl)acetate ligand, are reported. The influence of the steric effect on both the core geometry and coordination mode is observed. Temperature dependent (2.0-300 K range) magnetic susceptibility studies carried out on complexes 1 established unequivocally antiferromagnetic (AF) interactions between high-spin iron(iii) centers (S = 5/2), leading to a ground state S = 0. The mechanism of AF intramolecular coupling was proved using a broken-symmetry approach within the density functional method at the B3LYP/def2-TZVP(-f)/def2-SVP level of theory.

  15. Extracellular polymeric substances mediate bioleaching/biocorrosion via interfacial processes involving iron(III) ions and acidophilic bacteria.

    Science.gov (United States)

    Sand, Wolfgang; Gehrke, Tilman

    2006-01-01

    Extracellular polymeric substances seem to play a pivotal role in biocorrosion of metals and bioleaching, biocorrosion of metal sulfides for the winning of precious metals as well as acid rock drainage. For better control of both processes, the structure and function of extracellular polymeric substances of corrosion-causing or leaching bacteria are of crucial importance. Our research focused on the extremophilic bacteria Acidithiobacillus ferrooxidans and Leptospirillum ferrooxidans, because of the "simplicity" and knowledge about the interactions of these bacteria with their substrate/substratum and their environment. For this purpose, the composition of the corresponding extracellular polymeric substances and their functions were analyzed. The extracellular polymeric substances of both species consist mainly of neutral sugars and lipids. The functions of the exopolymers seem to be: (i) to mediate attachment to a (metal) sulfide surface, and (ii) to concentrate iron(III) ions by complexation through uronic acids or other residues at the mineral surface, thus, allowing an oxidative attack on the sulfide. Consequently, dissolution of the metal sulfide is enhanced, which may result in an acceleration of 20- to 100-fold of the bioleaching process over chemical leaching. Experiments were performed to elucidate the importance of the iron(III) ions complexed by extracellular polymeric substances for strain-specific differences in oxidative activity for pyrite. Strains of A. ferrooxidans with a high amount of iron(III) ions in their extracellular polymeric substances possess greater oxidation activity than those with fewer iron(III) ions. These data provide insight into the function of and consequently the advantages that extracellular polymeric substances provide to bacteria. The role of extracellular polymeric substances for attachment under the conditions of a space station and resulting effects like biofouling, biocorrosion, malodorous gases, etc. will be discussed.

  16. Nanoparticles of barium induce apoptosis in human phagocytes.

    Science.gov (United States)

    Mores, Luana; França, Eduardo Luzia; Silva, Núbia Andrade; Suchara, Eliane Aparecida; Honorio-França, Adenilda Cristina

    2015-01-01

    Nutrients and immunological factors of breast milk are essential for newborn growth and the development of their immune system, but this secretion can contain organic and inorganic toxins such as barium. Colostrum contamination with barium is an important issue to investigate because this naturally occurring element is also associated with human activity and industrial pollution. The study evaluated the administration of barium nanoparticles to colostrum, assessing the viability and functional activity of colostral mononuclear phagocytes. Colostrum was collected from 24 clinically healthy women (aged 18-35 years). Cell viability, superoxide release, intracellular Ca(2+) release, and phagocyte apoptosis were analyzed in the samples. Treatment with barium lowered mononuclear phagocyte viability, increased superoxide release, and reduced intracellular calcium release. In addition, barium increased cell death by apoptosis. These data suggest that nanoparticles of barium in colostrum are toxic to cells, showing the importance of avoiding exposure to this element.

  17. Barium Titanate Nanoparticles for Biomarker Applications

    International Nuclear Information System (INIS)

    Matar, O; Hondow, N S; Brydson, R M D; Milne, S J; Brown, A P; Posada, O M; Wälti, C; Saunders, M; Murray, C A

    2015-01-01

    A tetragonal crystal structure is required for barium titanate nanoparticles to exhibit the nonlinear optical effect of second harmonic light generation (SHG) for use as a biomarker when illuminated by a near-infrared source. Here we use synchrotron XRD to elucidate the tetragonal phase of commercially purchased tetragonal, cubic and hydrothermally prepared barium titanate (BaTiO 3 ) nanoparticles by peak fitting with reference patterns. The local phase of individual nanoparticles is determined by STEM electron energy loss spectroscopy (EELS), measuring the core-loss O K-edge and the Ti L 3 -edge energy separation of the t 2g , e g peaks. The results show a change in energy separation between the t 2g and e g peak from the surface and core of the particles, suggesting an intraparticle phase mixture of the barium titanate nanoparticles. HAADF-STEM and bright field TEM-EDX show cellular uptake of the hydrothermally prepared BaTiO 3 nanoparticles, highlighting the potential for application as biomarkers. (paper)

  18. Barium hexaferrite nanoparticles: Synthesis and magnetic properties

    International Nuclear Information System (INIS)

    Martirosyan, K.S.; Galstyan, E.; Hossain, S.M.; Wang Yiju; Litvinov, D.

    2011-01-01

    Carbon combustion synthesis is applied to rapid and energy efficient fabrication of crystalline barium hexaferrite nanoparticles with the average particle size of 50-100 nm. In this method, the exothermic oxidation of carbon nanoparticles with an average size of 5 nm with a surface area of 80 m 2 /g generates a self-propagating thermal wave with maximum temperatures of up to 1000 deg. C. The thermal front rapidly propagates through the mixture of solid reactants converting it to the hexagonal barium ferrite. Carbon is not incorporated in the product and is emitted from the reaction zone as a gaseous CO 2 . The activation energy for carbon combustion synthesis of BaFe 12 O 19 was estimated to be 98 kJ/mol. A complete conversion to hexagonal barium ferrite is obtained for carbon concentration exceeding 11 wt.%. The magnetic properties H c ∼3000 Oe and M s ∼50.3 emu/g of the compact sintered ferrites compare well with those produced by other synthesis methods.

  19. BARIUM REDUCTION OF INTUSSUSCEPTION IN INFANCY

    Science.gov (United States)

    Denenholz, Edward J.; Feher, George. S.

    1955-01-01

    Barium enema reduction was used as the initial routine treatment in 29 infants with intussusception. In 22 of them the intussusception was reduced by this means. In three of eight patients operated upon the intussusception was found to be reduced. Four of the remaining five patients had clinical or x-ray evidence of complications before reduction by barium enema was attempted. Twenty-one of the patients, all of whom were observed in private practice, were treated without admission to the hospital. After reduction, these patients were observed closely by the clinician. None of these patients showed clinical or x-ray signs of complications before reduction. Certain clinical and roentgen criteria must be satisfied before it can be concluded that reduction by barium enema is complete. If there are clinical signs of complications with x-ray evidence of small bowel obstruction, only a very cautious attempt at hydrostatic reduction should be made. As the time factor is generally a reliable clinical guide to reducibility, the late cases should be viewed with greater caution. Long duration of symptoms, however, is not per se a contraindication to an attempt at hydrostatic reduction. PMID:13230908

  20. Making of Magnet Barium Ferit Anisotropic

    International Nuclear Information System (INIS)

    Idayati, Novrita; Dedi

    2003-01-01

    Barium Hexa ferrite (BaFe 12 O 19 ) is ceramic and materials which usually used for making of permanent magnet. In this research Barium Hexa ferrite were made Anisotropic, and applied for loudspeaker, electro motors, dynamo, KWh metre, etc. this Magnet is commonly used due to its high Induction of Remanen (Br) and coercivity (high Hc). Besides it applies a more simple and easier process technology, cheaper raw material, and easy to find it, hence the magnetic component is much cheaper. Powder Metallurgy was used for the process technology, by reacting all materials in the powder (oxide), with a certain size distribution and a tight preparation step. The next step was mixing ferrite and Barium Carbonate (in the form of oxide), calcination, compaction, cantering and characterisation. The Anisotropic particle effects a high Induce Remanen (Br) and of koersifitas (high Hc). All the process steps will is determine physical and chemical characteristics of the magnet. The best Magnet characteristic of the magnet produced in this research is Induction of Remanen (Br) = 4,27 kg, Coercivity (Hc) = 1,745 kOe, Energy Product max (BHmaks) = 2,31 MGOe

  1. Kinematic and spatial distributions of barium stars - are the barium stars and Am stars related?

    International Nuclear Information System (INIS)

    Hakkila, J.

    1989-01-01

    The possibility of an evolutionary link between Am stars and barium stars is considered, and an examination of previous data suggests that barium star precursors are main-sequence stars of intermediate mass, are most likely A and/or F dwarfs, and are intermediate-mass binaries with close to intermediate orbital separations. The possible role of mass transfer in the later development of Am systems is explored. Mass transfer and loss from systems with a range of masses and orbital separations may explain such statistical peculiarities of barium stars as the large dispersion in absolute magnitude, the large range of elemental abundances from star to star, and the small number of stars with large peculiar velocities. 93 refs

  2. Effects of Barium Concentration on Oropharyngeal Swallow Timing Measures

    OpenAIRE

    Stokely, Shauna L.; Molfenter, Sonja M.; Steele, Catriona M.

    2013-01-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between “thin” (40 % w/v concentration) and “ultrathin” (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; ...

  3. Contrast characteristics of barium preparations and the timing of exposure

    OpenAIRE

    渋谷, 光一; 中桐, 義忠; 東, 義晴; 杉田, 勝彦; 小橋, 高郎; 大倉, 保彦; 丹谷, 延義; 三上, 泰隆; 平木, 祥夫

    1995-01-01

    We studied the relationship between the contrast characteristics of barium suspension and timing of exposure. We poured several kinds of barium preparations on the phantom manufactured by ourselves, and took X-ray pictures continuously by a DSA system. We analyzed each of the characteris-tics of the contrast. The time which was reguired for the contrast to reach the peak (Contrast Peak Time ; CPT) was unrelated with the kind of barium preparations used. It depended on the viscosity of the con...

  4. Barium peritonitis following upper gastrointestinal series: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Su Jin; Hwang, Ji Young; Kim, Yong Jin; Hong, Seong Sook [Soonchunhyang University College of Medicine, Seoul Hospital, Seoul (Korea, Republic of)

    2017-06-15

    We report a rare case of barium peritonitis following an upper gastrointestinal (GI) series and its imaging findings in a 74-year-old female. Barium peritonitis is a rare but life-threatening complication of GI contrast investigation. Therefore, clinical awareness of barium peritonitis as a complication of GI tract contrast investigation would help to prevent such a complication and manage the patients properly.

  5. Barium peritonitis following upper gastrointestinal series: A case report

    International Nuclear Information System (INIS)

    Ko, Su Jin; Hwang, Ji Young; Kim, Yong Jin; Hong, Seong Sook

    2017-01-01

    We report a rare case of barium peritonitis following an upper gastrointestinal (GI) series and its imaging findings in a 74-year-old female. Barium peritonitis is a rare but life-threatening complication of GI contrast investigation. Therefore, clinical awareness of barium peritonitis as a complication of GI tract contrast investigation would help to prevent such a complication and manage the patients properly

  6. Metal Fluorides, Metal Chlorides and Halogenated Metal Oxides as Lewis Acidic Heterogeneous Catalysts. Providing Some Context for Nanostructured Metal Fluorides.

    Science.gov (United States)

    Lennon, David; Winfield, John M

    2017-01-28

    Aspects of the chemistry of selected metal fluorides, which are pertinent to their real or potential use as Lewis acidic, heterogeneous catalysts, are reviewed. Particular attention is paid to β-aluminum trifluoride, aluminum chlorofluoride and aluminas γ and η, whose surfaces become partially fluorinated or chlorinated, through pre-treatment with halogenating reagents or during a catalytic reaction. In these cases, direct comparisons with nanostructured metal fluorides are possible. In the second part of the review, attention is directed to iron(III) and copper(II) metal chlorides, whose Lewis acidity and potential redox function have had important catalytic implications in large-scale chlorohydrocarbons chemistry. Recent work, which highlights the complexity of reactions that can occur in the presence of supported copper(II) chloride as an oxychlorination catalyst, is featured. Although direct comparisons with nanostructured fluorides are not currently possible, the work could be relevant to possible future catalytic developments in nanostructured materials.

  7. A study of the solvent effect on the chemical interaction between ortho-positronium and iron(III)-chloride

    International Nuclear Information System (INIS)

    Vertes, A.

    1980-01-01

    The chemical rate constant (k) between ortho-positronium (o-Ps) and iron(III)-chloride was measured in donor solvents as benzene, acetone, pyridine and ethanol. The minimal k was obtained in benzene and the maximal one in acetone. The minimal k value was explained by the low dispersity of FeCl 3 in benzene, and the high rate of the interaction in acetone was considered to be the result of the presence of monomer and dimer iron(III)-species and of the chloride coordination to iron(III). The probability of Ps formation depended only on the character of the solvent and not on the concentration of the FeCl 3 solute. (author)

  8. Effects of barium concentration on oropharyngeal swallow timing measures.

    Science.gov (United States)

    Stokely, Shauna L; Molfenter, Sonja M; Steele, Catriona M

    2014-02-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

  9. History and challenges of barium titanate: Part I

    Directory of Open Access Journals (Sweden)

    Vijatović M.M.

    2008-01-01

    Full Text Available Barium titanate is the first ferroelectric ceramics and a good candidate for a variety of applications due to its excellent dielectric, ferroelectric and piezoelectric properties. Barium titanate is a member of a large family of compounds with the general formula ABO3 called perovskites. Barium titanate can be prepared using different methods. The synthesis method depends on the desired characteristics for the end application. The used method has a significant influence on the structure and properties of barium titanate materials. In this review paper, Part I contains a study of the BaTiO3 structure and frequently used synthesis methods.

  10. Lanthanide doped strontium-barium cesium halide scintillators

    Science.gov (United States)

    Bizarri, Gregory; Bourret-Courchesne, Edith; Derenzo, Stephen E.; Borade, Ramesh B.; Gundiah, Gautam; Yan, Zewu; Hanrahan, Stephen M.; Chaudhry, Anurag; Canning, Andrew

    2015-06-09

    The present invention provides for a composition comprising an inorganic scintillator comprising an optionally lanthanide-doped strontium-barium, optionally cesium, halide, useful for detecting nuclear material.

  11. Chloride ingress prediction

    DEFF Research Database (Denmark)

    Frederiksen, Jens Mejer; Geiker, Mette Rica

    2008-01-01

    Prediction of chloride ingress into concrete is an important part of durability design of reinforced concrete structures exposed to chloride containing environment. This paper presents experimentally based design parameters for Portland cement concretes with and without silica fume and fly ash...... in marine atmospheric and submersed South Scandinavian environment. The design parameters are based on sequential measurements of 86 chloride profiles taken over ten years from 13 different types of concrete. The design parameters provide the input for an analytical model for chloride profiles as function...... of depth and time, when both the surface chloride concentration and the diffusion coefficient are allowed to vary in time. The model is presented in a companion paper....

  12. Moessbauer spectroscopic evidence for iron(III) complexation and reduction in acidic aqueous solutions of indole-3-butyric acid

    International Nuclear Information System (INIS)

    Kovacs, K.; Kuzmann, E.; Vertes, A.; Kamnev, A.A.; Shchelochkov, A.G.; Medzihradszky-Schweiger, H.; Mink, J.; Hungarian Academy of Sciences, Budapest

    2004-01-01

    Moessbauer spectroscopic studies were carried out in acidic (pH 2.3) 57 Fe III nitrate containing aqueous solutions of indole-3-butyric acid (IBA), rapidly frozen in liquid nitrogen at various periods of time after mixing the reagents. The data obtained show that in solution in the presence of IBA, iron(III) forms a complex with a dimeric structure characterised by a quadrupole doublet, whereas without IBA under similar conditions iron(III) exhibits a broad spectral feature due to a slow paramagnetic spin relaxation which, at liquid nitrogen temperature, results in a large anomalous line broadening (or, at T = 4.2 K, in a hyperfine magnetic splitting). The spectra of 57 Fe III +IBA solutions, kept at ambient temperature under aerobic conditions for increasing periods of time before freezing, contained a gradually increasing contribution of a component with a higher quadrupole splitting. The Moessbauer parameters for that component are typical for iron(II) aquo complexes, thus showing that under these conditions gradual reduction of iron(III) occurs, so that the majority (85%) of dissolved iron(III) is reduced within 2 days. The Moessbauer parameters for the iron(III)-IBA complex in aqueous solution and in the solid state (separated from the solution by filtration) were found to be similar, which may indicate that the dissolved and solid complexes have the same composition and/or iron(III) coordination environment. For the solid complex, the data of elemental analysis suggest the following composition of the dimer: [L 2 Fe-(OH) 2 -FeL 2 ] (where L is indole-3-butyrate). This structure is also in agreement with the data of infrared spectroscopic study of the complex reported earlier, with the side-chain carboxylic group in indole-3-butyrate as a bidentate ligand. The Moessbauer parameters for the solid 57 Fe III -IBA complex at T = 80 K and its acetone solution rapidly frozen in liquid nitrogen were virtually identical, which indicates that the complex retains its

  13. Binding and leakage of barium in alginate microbeads.

    Science.gov (United States)

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  14. Chloride flux in phagocytes.

    Science.gov (United States)

    Wang, Guoshun

    2016-09-01

    Phagocytes, such as neutrophils and macrophages, engulf microbes into phagosomes and launch chemical attacks to kill and degrade them. Such a critical innate immune function necessitates ion participation. Chloride, the most abundant anion in the human body, is an indispensable constituent of the myeloperoxidase (MPO)-H2 O2 -halide system that produces the potent microbicide hypochlorous acid (HOCl). It also serves as a balancing ion to set membrane potentials, optimize cytosolic and phagosomal pH, and regulate phagosomal enzymatic activities. Deficient supply of this anion to or defective attainment of this anion by phagocytes is linked to innate immune defects. However, how phagocytes acquire chloride from their residing environment especially when they are deployed to epithelium-lined lumens, and how chloride is intracellularly transported to phagosomes remain largely unknown. This review article will provide an overview of chloride protein carriers, potential mechanisms for phagocytic chloride preservation and acquisition, intracellular chloride supply to phagosomes for oxidant production, and methods to measure chloride levels in phagocytes and their phagosomes. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Gluten content of barium sulfate suspensions used for barium swallows in patients with celiac disease.

    Science.gov (United States)

    Chiu, Jennifer G; Shin, Yoona; Patel, Priti N; Mangione, Robert A

    2014-01-01

    To determine the availability and accuracy of information provided by hospitals, imaging centers, and manufacturers regarding gluten in barium sulfate suspensions. A total of 105 facilities were contacted via telephone to determine the gluten content of the contrast media used in those facilities. Manufacturers were contacted and their Web sites reviewed to determine the gluten content of their barium products. Thirty-nine percent of the hospitals and 52% of the imaging centers were not aware of the gluten content of the contrast media they used. Twenty-nine-and-a-half percent of the respondents provided the correct gluten content. The manufacturers noted that 5 products were tested and confirmed gluten free, 1 product was not tested but described as gluten free, 1 product's gluten content depended upon its flavor, and 1 product was reported to contain gluten. Clinicians caring for patients with celiac disease or patients who choose to restrict their gluten consumption must ensure that the barium sulfate suspension ingested is gluten free. It can be difficult to determine the gluten content of barium sulfate, as a majority of radiology departments and imaging centers did not know whether the product they use is gluten free. Educating staff members and improving product labeling would benefit the quality of care provided to patients with celiac disease.

  16. A Novel Sensor for Monitoring of Iron(III) Ions Based on Porphyrins

    Science.gov (United States)

    Vlascici, Dana; Fagadar-Cosma, Eugenia; Popa, Iuliana; Chiriac, Vlad; Gil-Agusti, Mayte

    2012-01-01

    Three A3B porphyrins with mixed carboxy-, phenoxy-, pyridyl-, and dimethoxy-substituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 × 10−7–1 × 10−1 M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples. PMID:22969395

  17. Crystal structures and Moessbauer spectra of spin-crossover iron(III) complexes of quinquedentate ligands

    International Nuclear Information System (INIS)

    Maeda, Yonezo; Noda, Yosuke; Oshio, Hiroki; Takashima, Yoshimasa; Matsumoto, Naohide

    1994-01-01

    Magnetic properties, Moessbauer spectra and crystal structures of spin-crossover iron(III) complexes with a quinquedentate ligand [FeLX]BPh 4 are reported. X and L denote a unidentate ligand and a quinquedentate ligand, respectively. [Fe(mbpN)(im)]BPh 4 shows spin-crossover behavior in an appropriate organic solvent, and [Fe(mbpN)(lut)]BPh 4 , [Fe(bpN)(py)]BPh 4 and [Fe(salten)X]BPh 4 (X = 4me-py or 2me-im) show spin-crossover behavior in a solid and in an organic solvent. It was found that the ligand field strength of salten was stronger than that of mbpN. The rates of spin-state interexchange in the complexes are as fast as the inverse of the lifetime (1 x 10 -7 s) of the Moessbauer nuclear level. The Moessbauer spectroscopic behavior of [Fe(mbpN)(lut)]BPh 4 and [Fe(bpN)(py)]BPh 4 is different to that of [Fe(salten)X]BPh 4 (X = 4me-py or 2me-im). The difference was ascribed to the different geometrical positions of the corresponding anions. (orig.)

  18. Nitrogen loss from anaerobic ammonium oxidation coupled to Iron(III) reduction in a riparian zone.

    Science.gov (United States)

    Ding, Bangjing; Li, Zhengkui; Qin, Yunbin

    2017-12-01

    Anaerobic ammonium oxidation coupled to iron(III) reduction (termed Feammox) is a recently discovered pathway of nitrogen cycling. However, little is known about the pathways of N transformation via Feammox process in riparian zones. In this study, evidence for Feammox in riparian zones with or without vegetation cover was demonstrated using isotope tracing technique and high-throughput sequencing technology. The results showed that Feammox could occur in riparian zones, and demonstrated that N 2 directly from Feammox was dominant Feammox pathway. The Feammox rates in vegetated soil samples was 0.32-0.37 mg N kg -1 d -1 , which is higher than that in un-vegetated soil samples (0.20 mg N kg -1 d -1 ). Moreover, the growth of vegetation led to a 4.99-6.41% increase in the abundance of iron reducing bacteria (Anaeromyxobacter, Pseudomonas and Geobacter) and iron reducing bacteria play an essential role in Feammox process. An estimated loss of 23.7-43.9 kg N ha -1 year -1 was associated with Feammox in the examined riparian zone. Overall, the co-occurrence of ammonium oxidation and iron reduction suggest that Feammox can play an essential role in the pathway of nitrogen removal in riparian zones. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Efficient catalytic cycloalkane oxidation employing a "helmet" phthalocyaninato iron(III) complex.

    Science.gov (United States)

    Brown, Elizabeth S; Robinson, Jerome R; McCoy, Aaron M; McGaff, Robert W

    2011-06-14

    We have examined the catalytic activity of an iron(III) complex bearing the 14,28-[1,3-diiminoisoindolinato]phthalocyaninato (diiPc) ligand in oxidation reactions with three substrates (cyclohexane, cyclooctane, and indan). This modified metallophthalocyaninato complex serves as an efficient and selective catalyst for the oxidation of cyclohexane and cyclooctane, and to a far lesser extent indan. In the oxidations of cyclohexane and cyclooctane, in which hydrogen peroxide is employed as the oxidant under inert atmosphere, we have observed turnover numbers of 100.9 and 122.2 for cyclohexanol and cyclooctanol, respectively. The catalyst shows strong selectivity for alcohol (vs. ketone) formation, with alcohol to ketone (A/K) ratios of 6.7 and 21.0 for the cyclohexane and cyclooctane oxidations, respectively. Overall yields (alcohol + ketone) were 73% for cyclohexane and 92% for cyclooctane, based upon the total hydrogen peroxide added. In the catalytic oxidation of indan under similar conditions, the TON for 1-indanol was 10.1, with a yield of 12% based upon hydrogen peroxide. No 1-indanone was observed in the product mixture.

  20. Iron(III Fluorinated Porphyrins: Greener Chemistry from Synthesis to Oxidative Catalysis Reactions

    Directory of Open Access Journals (Sweden)

    Susana L. H. Rebelo

    2016-04-01

    Full Text Available Iron(III fluorinated porphyrins play a central role in the biomimetics of heme enzymes and enable cleaner routes to the oxidation of organic compounds. The present work reports significant improvements in the eco-compatibility of the synthesis of 5,10,15,20-tetrakis-pentafluorophenylporphyrin (H2TPFPP and the corresponding iron complex [Fe(TPFPPCl], and the use of [Fe(TPFPPCl] as an oxidation catalyst in green conditions. The preparations of H2TPFPP and [Fe(TPFPPCl] typically use toxic solvents and can be made significantly greener and simpler using microwave heating and optimization of the reaction conditions. In the optimized procedure it was possible to eliminate nitrobenzene from the porphyrin synthesis and replace DMF by acetonitrile in the metalation reaction, concomitant with a significant reduction of reaction time and simplification of the purification procedure. The Fe(IIIporphyrin is then tested as catalyst in the selective oxidation of aromatics at room temperature using a green oxidant (hydrogen peroxide and green solvent (ethanol. Efficient epoxidation of indene and selective oxidation of 3,5-dimethylphenol and naphthalene to the corresponding quinones is observed.

  1. Iron(III) Fluorinated Porphyrins: Greener Chemistry from Synthesis to Oxidative Catalysis Reactions.

    Science.gov (United States)

    Rebelo, Susana L H; Silva, André M N; Medforth, Craig J; Freire, Cristina

    2016-04-12

    Iron(III) fluorinated porphyrins play a central role in the biomimetics of heme enzymes and enable cleaner routes to the oxidation of organic compounds. The present work reports significant improvements in the eco-compatibility of the synthesis of 5,10,15,20-tetrakis-pentafluorophenylporphyrin (H₂TPFPP) and the corresponding iron complex [Fe(TPFPP)Cl], and the use of [Fe(TPFPP)Cl] as an oxidation catalyst in green conditions. The preparations of H₂TPFPP and [Fe(TPFPP)Cl] typically use toxic solvents and can be made significantly greener and simpler using microwave heating and optimization of the reaction conditions. In the optimized procedure it was possible to eliminate nitrobenzene from the porphyrin synthesis and replace DMF by acetonitrile in the metalation reaction, concomitant with a significant reduction of reaction time and simplification of the purification procedure. The Fe(III)porphyrin is then tested as catalyst in the selective oxidation of aromatics at room temperature using a green oxidant (hydrogen peroxide) and green solvent (ethanol). Efficient epoxidation of indene and selective oxidation of 3,5-dimethylphenol and naphthalene to the corresponding quinones is observed.

  2. A novel sensor for monitoring of iron(III) ions based on porphyrins.

    Science.gov (United States)

    Vlascici, Dana; Fagadar-Cosma, Eugenia; Popa, Iuliana; Chiriac, Vlad; Gil-Agusti, Mayte

    2012-01-01

    Three A(3)B porphyrins with mixed carboxy-, phenoxy-, pyridyl-, and dimethoxy-substituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 × 10(-7)-1 × 10(-1) M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples.

  3. Outcome of barium enema in patients with colorectal symptoms ...

    African Journals Online (AJOL)

    Background: For many years, double contrast barium enema has been an effective way to evaluate the large bowel. With the development of the colonoscope, the role of barium enema has been questioned. However it is still useful in investigating patients with colorectal symptoms especially in the developing world where ...

  4. Synthesis and properties of barium diketonates as precursors for MOCVD

    Energy Technology Data Exchange (ETDEWEB)

    Drozdov, A.A. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Troyanov, S.I. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Kuzmina, N.P. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Martynenko, L.I. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Alikhanyan, A.S. (Dept. of Chemistry, Moscow State Univ. (Russian Federation)); Malkerova, I.P. (Dept. of Chemistry, Moscow State Univ. (Russian Federation))

    1993-08-01

    The structures of barium diketonates depend on the way in which they are synthesized. It is shown that there is a correlation between the volatility of these compounds and their crystal structures. A new volatile mononuclear adduct of barium dipivaloylmethanate suitable for MOCVD is suggested. (orig.).

  5. Synthesis and properties of barium diketonates as precursors for MOCVD

    International Nuclear Information System (INIS)

    Drozdov, A.A.; Troyanov, S.I.; Kuzmina, N.P.; Martynenko, L.I.; Alikhanyan, A.S.; Malkerova, I.P.

    1993-01-01

    The structures of barium diketonates depend on the way in which they are synthesized. It is shown that there is a correlation between the volatility of these compounds and their crystal structures. A new volatile mononuclear adduct of barium dipivaloylmethanate suitable for MOCVD is suggested. (orig.)

  6. Thermal reactions of some calcium, strontium, and barium chromates

    International Nuclear Information System (INIS)

    Piekarska-Piesse, B.; Gontarz, Z.; Ostrowski, A.; Kucharski, R.

    2000-01-01

    Thermal decomposition of calcium chromates and solid state reactions of barium and strontium chromates(VI) with barium and strontium hydroxides and carbonates, as well as the reduction of chromates by carbon and hydrogen, have been investigated. The mechanisms of individual stages of the thermal decomposition have been proposed on the basis of morphological classification. (author)

  7. Charge distributions of barium isotopes from muonic X-rays

    International Nuclear Information System (INIS)

    Shera, E.B.; Wohlfahrt, H.D.; Hoehn, M.V.; Tanaka, Y.

    1982-01-01

    The results of a muonic X-ray study of the charge radii of stable barium isotopes are presented and compared with optical isotope shifts. The isotope shifts Δ 2 > of a wide range of barium isotopes are found to be in good agreement with the droplet model and with IBA calculations. (orig.)

  8. Barium transport in the hot spot region of fluorescent lamps

    International Nuclear Information System (INIS)

    Sigeneger, F; Rackow, K; Uhrlandt, D; Ehlbeck, J; Lieder, G

    2010-01-01

    The transport of barium atoms and ions in the vicinity of the hot spot in fluorescent lamps operating at 25 kHz is investigated by a combined experimental and theoretical approach. By laser-induced fluorescence, the particle densities of barium atoms and ions were measured time-resolved at different distances from the spot centre. In addition, the time-dependent cathode fall voltage was measured using an improved band method. The model combines a kinetic part for the electrons with a fluid part for the barium atoms and ions. Both parts are spatially resolved in spherically symmetric geometry. The space-dependent electron Boltzmann equation yields the electron density and the ionization rate coefficient of barium as functions of the cathode fall voltage. These results are used to solve the time-dependent particle balance equations of barium atoms and ions which include the ionization of barium as gain and loss terms, respectively. Good agreement between the measured and calculated particle densities of barium atoms is obtained. A sensitive dependence of the ionization frequency and of the barium particle densities on the cathode fall voltage was found.

  9. Barium enema findings of milk allergy in infants

    International Nuclear Information System (INIS)

    Kim, Gyoung Ju; Kim, Mi Jeong; Lee, Hee Jung

    2006-01-01

    We wanted to evaluate the barium enema findings of milk allergy in infants. Retrospective evaluation of the plain abdominal radiography and barium enema findings was performed in fifteen young infants suffering with milk allergy. The presence of gaseous distension, rectal gas, paralytic ileus and mechanical obstruction was evaluated on the plain radiography. The presence of spasm, a transitional zone, a reversed rectosigmoid index and mucosal irregularity was analyzed on the barium enema; the presence of barium retention was also evaluated on 24-hour-delayed plain radiography. Paralytic ileus was the most common finding on the plain radiography (93%). On the barium enema, continuous spasm of the colon, ranging from the rectum to the descending colon, was revealed in ten infants (67%). A transitional zone was observed in one infant and a reversed rectosigmoid index was revealed in four. Mucosal irregularity was observed in two infants. Barium retention was demonstrated in 11 of fifteen cases: throughout the entire colon (n = 3), from the rectum to the descending colon (n = 7), and up to the transverse colon (n = 1). The most common barium enema finding of milk allergy in infants was spasm of the distal colon. The other findings were a transitional zone, a reversed rectosigmoid index, mucosal irregularity and barium retention

  10. INFLUENCE OF BARIUM OXIDE ADDITIONS ON PORTLAND CLINKER

    Directory of Open Access Journals (Sweden)

    Anezka Zezulova

    2016-12-01

    Full Text Available Nowadays, nuclear power plants are widespread around the world and research is of great interest. Together with nuclear research, shielding of different types of radiation is an important current topic of research aiming at their safety. Portland cement has been an elementary building material for centuries. Since barium is very efficient in shielding different types of radiation, it can be assumed that the radiation shielding capability of cement can be improved by incorporation of barium. This work deals with the influence of barium oxide, added in the form of barium carbonate and sulphate, on the formation and properties of Portland clinker. The structure of burnt clinkers and the ratio of clinker phases were studied by polarizing microscopy and by X-ray diffraction. With increasing barium content, the alite-belite ratio decreases and the content of free lime gradually increases. Moreover, sulphates induce the growth of alite crystals. The ability of barium to be a part of the clinker minerals was observed by scanning electron microscopy. Belite and clinker melt contain the highest amount of barium, but aggregates of barium oxide are formed in the clinker melt. Furthermore, the rate of alite crystallization was studied under isothermal conditions.

  11. Application of magnesium hydroxide and barium hydroxide for the ...

    African Journals Online (AJOL)

    Application of magnesium hydroxide and barium hydroxide for the removal of metals and sulphate from mine water. ... equivalent to the Ba(OH)2 dosage. During CO2-dosing, CaCO3 is precipitated to the saturation level of CaCO3. Keywords: Magnesium hydroxide; barium hydroxide; sulphate removal; water treatment ...

  12. Duodenal diverticula demonstrated by barium examination

    Energy Technology Data Exchange (ETDEWEB)

    Christiansen, T.; Thommesen, P.

    An investigation for biliary tract calculi and food-stimulated gastro-oesophageal reflux was carried out in 37 patients with duodenal diverticula demonstrated by barium examination. Sixty per cent of the diverticula were located in the descending part of the duodenum. Biliary tract calculi were demonstrated in 38 per cent and food-stimulated gastro-oesophageal reflux in 81 per cent of the patients. The detection of a duodenal diverticulum should result in a supplementary investigation for gallstones and gastrooesophageal reflux and its sequelae.

  13. Short-cavity squeezing in barium

    Science.gov (United States)

    Hope, D. M.; Bachor, H-A.; Manson, P. J.; Mcclelland, D. E.

    1992-01-01

    Broadband phase sensitive noise and squeezing were experimentally observed in a system of barium atoms interacting with a single mode of a short optical cavity. Squeezing of 13 +/- 3 percent was observed. A maximum possible squeezing of 45 +/- 8 percent could be inferred for out experimental conditions, after correction for measured loss factors. Noise reductions below the quantum limit were found over a range of detection frequencies 60-170 MHz and were best for high cavity transmission and large optical depths. The amount of squeezing observed is consistent with theoretical predictions from a full quantum statistical model of the system.

  14. Evaluation of barium hydroxide treatment efficacy on a dolomitic marble.

    Science.gov (United States)

    Toniolo, L; Colombo, C; Realini, M; Peraio, A; Positano, M

    2001-01-01

    The Arch of Peace, by Luigi Cagnola, is one of the most famous neoclassical monuments in Milan. It has been subjected to conservative intervention in 1998. In the present paper the efficacy of the consolidation by means of barium hydroxide has been evaluated. The stone material showed severe degradation phenomena as: erosion, pulverisation, exfoliation. The analytical data acquired through X-ray diffraction (XRD), infrared spectrophotometry (FTIR) and scanning electron microscopy (SEM-EDX), allowed to compare the conditions of stone before and after the treatment with barium hydroxide. The presence of barium has been put in evidence mainly on the surface as barium sulphate, whereas barium is only sporadically present within the thickness of the decayed material. The treatment was judged not satisfying and its inefficacy is, most probably, due to a not suitable cleaning procedure carried out before the consolidation.

  15. Barium and radium migration in unconsolidated Canadian geological materials

    International Nuclear Information System (INIS)

    Gillham, R.W.; Sharma, H.D.; Reddy, M.R.; Cooper, E.L.; Cherry, J.A.

    1981-05-01

    This report describes the results of laboratory studies on the distribution coefficients of radium and barium in samples of unconsolidated geologic materials. Graphs of Ksub(d) versus solution concentration for the respective elements showed constant Ksub(d) values in the low concentration range suggesting that, at low concentrations, a distribution coefficient is a valid means of representing the geochemical reactions of both barium and radium. The Ksub(d) values for barium range between 60 and 3500 ml/g. The values appear to be influenced by the amount of barium occurring naturally in the soil materials and thus there is little possiblility of using barium as an analog of radium in laboratory experiments. The Ksub(d) values of radium vary from 50 to 1000 ml/g indicating that a wide range of geological materials have a substantial capacity to retard the migration of radium

  16. Barium sulfate aspiration: Severe chemical pneumonia induced by a massive reflux of contrast medium during small bowel barium enema.

    Science.gov (United States)

    Zhang, Lin; Yang, Yi; Zhang, Ji; Zhou, Xiaowei; Dong, Hongmei; Zhou, Yiwu

    2015-08-01

    Barium contrast radiography is a conventional procedure aimed at revealing lesions of the alimentary tract using barium sulfate on X-ray irradiation. Although it is widely used in clinics, adverse effects and complications are observed, such as anaphylaxis, granuloma, fecalithes, abdomen-leaking, embolism, bacterial contamination, and aspiration. We report a case of death due to a massive barium sulfate aspiration resulted from an air-barium double contrast enema radiography. A 25-year-old female patient was hospitalized with symptoms of abdominal distention, nausea, vomiting and diarrhea for three days. A progressive respiratory distress presented only 1h after a small bowel air-barium double contrast enema. The patient died 11h later. The result of autopsy revealed the cause of death to be severe chemical pneumonitis induced by gastric fluid which was aspirated into her lungs. Barium sulfate is generally recognized to be chemically inert for the respiratory system, but a mixture of barium sulfate with gastric contents is fatal. Here we intend to suggest that, when determining the potential cause of death, medical examiners should consider a patient's status quo as well as the possible adverse effects and complications caused by the barium sulfate preparation during gastrointestinal radiography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Developmental effects of barium exposure in a marine bivalve (Mytilus californianus)

    International Nuclear Information System (INIS)

    Spangenberg, J.V.; Cherr, G.N.; Univ. of California, Davis, CA

    1996-01-01

    Produced water, an aqueous waste of variable composition associated with petroleum and natural gas extraction, is frequently discharged into the marine environment in significant quantities. Concern and controversy exist regarding potential adverse environmental effects related to such discharges. Previous reports indicated that barium (Ba) and/or strontium (Sr) were primarily responsible for the toxicity of a southern California produced water to developing marine embryos. To further investigate toxicity of Ba and Sr in seawater, mussel embryos (Mytilus californianus) were subjected to static exposures of barium acetate and strontium chloride from fertilization through veliger formation. Only Ba exhibited bioactivity at environmentally relevant levels. Adverse effects occurred between 200 and 900 microg/L (ppb); higher concentrations were associated with decreased toxicity and apparent precipitation of Ba salts from seawater. Nominal Ba exposure concentrations between 100 and 900 microg/L yielded measured concentrations of 100 to 550 microg/L soluble Ba when analyzed by inductively coupled argon plasma emission spectroscopy. Adverse developmental effects included abnormal shell calcification and embryo morphology. Exposure of embryos to Ba in state-specific experiments revealed that developmental stages were differentially affected, though they exhibited similar abnormalities. Gastrulae were the most sensitive, while blastula and trochophore larvae were less so. Adverse effects in embryos exposed during the gastrula stage were not reversible despite washing and return to clean seawater. These findings are among the first to demonstrate that low concentrations of soluble Ba in seawater can be toxic and are of potential concern in the marine environment

  18. Precipitation method for barium metaborate (BaB2O4) synthesis from borax solution

    International Nuclear Information System (INIS)

    Akşener, Eymen; Figen, Aysel Kantürk; Pişkin, Sabriye

    2013-01-01

    In this study, barium metaborate (BaB 2 O 4 , BMB) synthesis from the borax solution was carried out. BMB currently is used in production of ceramic glazes, luminophors, oxide cathodes as well as additives to pigments for aqueous emulsion paints and also β−BaB 2 O 4 single crystals are the best candidate for fabrication of solid-state UV lasers operating at a wavelength of 200 nm due to excellent nonlinear optical properties. In the present study, synthesis was carried out from the borax solution (Na 2 B 4 O 7⋅ 10H 2 O, BDH) and barium chloride (BaCI 2⋅ 2H 2 O, Ba) in the glass-batch reactor with stirring. The effect of, times (5-15 min), molar ratio [stoich.ration (1.0:2.0), 1.25:2.0, 1.5:2.0, 2.5:2:0, 3.0:2.0, 3.5:2.0,4.0:2.0, 5.0:2.0] and also crystallization time (2-6 hour) on the BMB yield (%) was investigated at 80 °C reaction temperature. It is found that, BMB precipitation synthesis with 90 % yield can be performed from 0.50 molar ration (BDH:Ba), under 80 °C, 15 minute, and 6 hours crystallization time. The structural properties of BMB powders were characterized by using XRD, FT-IR and DTA-TG instrumental analysis technique

  19. Precipitation method for barium metaborate (BaB2O4) synthesis from borax solution

    Science.gov (United States)

    Akşener, Eymen; Figen, Aysel Kantürk; Pişkin, Sabriye

    2013-12-01

    In this study, barium metaborate (BaB2O4, BMB) synthesis from the borax solution was carried out. BMB currently is used in production of ceramic glazes, luminophors, oxide cathodes as well as additives to pigments for aqueous emulsion paints and also β-BaB2O4 single crystals are the best candidate for fabrication of solid-state UV lasers operating at a wavelength of 200 nm due to excellent nonlinear optical properties. In the present study, synthesis was carried out from the borax solution (Na2B4O7ṡ10H2O, BDH) and barium chloride (BaCI2ṡ2H2O, Ba) in the glass-batch reactor with stirring. The effect of, times (5-15 min), molar ratio [stoich.ration (1.0:2.0), 1.25:2.0, 1.5:2.0, 2.5:2:0, 3.0:2.0, 3.5:2.0,4.0:2.0, 5.0:2.0] and also crystallization time (2-6 hour) on the BMB yield (%) was investigated at 80 °C reaction temperature. It is found that, BMB precipitation synthesis with 90 % yield can be performed from 0.50 molar ration (BDH:Ba), under 80 °C, 15 minute, and 6 hours crystallization time. The structural properties of BMB powders were characterized by using XRD, FT-IR and DTA-TG instrumental analysis technique.

  20. Oxidation of Dodecanoate Intercalated Iron(II)–Iron(III) Layered Double Hydroxide to Form 2D Iron(III) (Hydr)oxide Layers

    DEFF Research Database (Denmark)

    Huang, Li‐Zhi; Ayala‐Luis, Karina B.; Fang, Liping

    2013-01-01

    hydroxide planar layer were preserved during the oxidation, as shown by FTIR spectroscopy. The high positive charge in the hydroxide layer produced by the oxidation of iron(II) to iron(III) is partially compensated by the deprotonation of hydroxy groups, as shown by X‐ray photoelectron spectroscopy...... between the alkyl chains of the intercalated dodecanoate anions play a crucial role in stabilizing the structure and hindering the collapse of the iron(II)–iron(III) (hydr)oxide structure during oxidation. This is the first report describing the formation of a stable planar layered octahedral iron......(III) (hydr)oxide. oxGRC12 shows promise as a sorbent and host for hydrophobic reagents, and as a possible source of single planar layers of iron(III) (hydr)oxide....

  1. NANOSCALE BARIUM HYDROSILICATES: CHOOSING THE SYNTHESIS TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    GRISHINA Anna Nikolaevna

    2013-08-01

    Full Text Available Cement concretes are the most used materials in modern civil engineering. Due to that such materials draw great attention both in the Russian Federation and abroad. The possibility to enhance the manufacturability and operational properties of concretes results in significant reduction of overall operating costs. Many enhancement methods have been elaborated. Among them there is one based on introduction of calcium hydrosilicates into construction composition. The authors set up a hypothesis that similarity between properties and structures of different hydrosilicates (for example, alkaline earth metals and metals of the second group will provide similar increased operational characteristics. The specialists of Research and Educational Center «Nanotechnology» are developing cement composites nanomodification methods which include introduction of nanodimensional barium hydrosilicates particles. The synthesis of barium hydrosilicates particles can be done with the use of many technologies, different by energy consumption or performing complexity. Taking into account both these factors, one can assume that low-temperature sol-gel synthesis from diluted water solutions is the proper technology. The present paper shows that this assumption is correct. The selection of certain technology is made by the means of multiobjective optimization, which is in turn is performed by the means of linear scalarization. This method, while not always giving the Pareto optimal solutions, can be easily implemented. The particle size distribution is taken into consideration during selection of objectives and weights. It is shown that selected technology allows manufacturing nanoparticles with median size about 30 nm.

  2. High resolution studies of barium Rydberg states

    International Nuclear Information System (INIS)

    Eliel, E.R.

    1982-01-01

    The subtle structure of Rydberg states of barium with orbital angular momentum 0, 1, 2 and 3 is investigated. Some aspects of atomic theory for a configuration with two valence electrons are reviewed. The Multi Channel Quantum Defect Theory (MQDT) is concisely introduced as a convenient way to describe interactions between Rydberg series. Three high-resolution UV studies are presented. The first two, presenting results on a transition in indium and europium serve as an illustration of the frequency doubling technique. The third study is of hyperfine structure and isotope shifts in low-lying p states in Sr and Ba. An extensive study of the 6snp and 6snf Rydberg states of barium is presented with particular emphasis on the 6snf states. It is shown that the level structure cannot be fully explained with the model introduced earlier. Rather an effective two-body spin-orbit interaction has to be introduced to account for the observed splittings, illustrating that high resolution studies on Rydberg states offer an unique opportunity to determine the importance of such effects. Finally, the 6sns and 6snd series are considered. The hyperfine induced isotope shift in the simple excitation spectra to 6sns 1 S 0 is discussed and attention is paid to series perturbers. It is shown that level mixing parameters can easily be extracted from the experimental data. (Auth.)

  3. Three barium diphosphonates with 3-D structures

    Science.gov (United States)

    Tuikka, Matti; Haukka, Matti; Ahlgrén, Markku

    2007-06-01

    The gel crystallization method was exploited in this work in order to study the 3-D solid state structures of barium diphosphonates. This technique proved to be an effective tool for the growth of single crystals of diphosphonates for structure analysis. By using this approach, three barium diphosphonates, Ba[HO 3P(CH 2) 2PO 3H] ( 1), Ba 2[O 3P(CH 2) 3PO 3]·3H 2O ( 2) and Ba[HO 3P(CH 2) 4PO 3H] ( 3), with different three dimensional structures, were synthesized and characterized. The structures of compounds 1 and 2 were determined by single crystal X-ray diffraction and the structure of 3 by the powder diffraction method. In the structure of 1, the diphosphonate ligand is completely surrounded by the Ba atoms, which is an unusual arrangement in a diphosphonate system. The structures of 2 and 3 are more conventional. They are organized in typical pillared layers in which the separation of the layers can be adjusted by varying the length of the hydrocarbon chain.

  4. Effect of prolonged gelling time on the intrinsic properties of barium alginate microcapsules and its biocompatibility.

    Science.gov (United States)

    Vaithilingam, Vijayaganapathy; Kollarikova, Gabriella; Qi, Meirigeng; Lacik, Igor; Oberholzer, Jose; Guillemin, Gilles J; Tuch, Bernard E

    2011-01-01

    Pericapsular fibrotic overgrowth (PFO) may be attributed to an immune response against microcapsules themselves or to antigen shedding through microcapsule pores from encapsulated islet tissue. Modification of microcapsules aimed at reducing pore size should prevent PFO and improve graft survival. This study investigated the effect of increased gelling time (20 vs. 2 min) in barium chloride on intrinsic properties of alginate microcapsules and tested their biocompatibility in vivo. Prolonged gelling time affected neither permeability nor size of the microcapsules. However, prolonged gelling time for 20 min produced brittle microcapsules compared to 2 min during compression test. Encapsulation of human islets in both types of microcapsules affected neither islet viability nor function. The presence of PFO when transplanted into a large animal model such as baboon and its absence in small animal models such as rodents suggest that the host immune response towards alginate microcapsules is species rather than alginate specific.

  5. Radiation doses to patients undergoing barium meal and barium enema examinations

    International Nuclear Information System (INIS)

    Delichas, M. G.; Hatziioannou, K.; Papanastassiou, E.; Albanopoulou, P.; Chatzi, E.; Sioundas, A.; Psarrakos, K.

    2004-01-01

    The radiation doses received by patients during 41 barium meal (BM) and 42 barium enema (BE) examinations in two Greek hospitals are presented. Radiation dose was measured in terms of the dose area product (DAP). The effective dose and doses to certain organs were estimated using the ODS-60 software. Mean total DAP values were found to be 25 ± 11 Gy cm 2 for BM and 60 ± 35 Gy cm 2 for BE examinations, whereas the estimated mean values of effective dose were 8.6 ± 4.0 and 24 ± 16 mSv respectively. DAP to effective dose conversion coefficients were estimated to be 0.34 mSv per Gy cm 2 for BM and 0.41 mSv per Gy cm 2 for BE. (authors)

  6. Hydrolytic enzyme activity enhanced by Barium supplementation

    Directory of Open Access Journals (Sweden)

    Camilo Muñoz

    2016-10-01

    Full Text Available Hydrolysis of polymers is a first and often limiting step during the degradation of plant residues. Plant biomass is generally a major component of waste residues and a major renewable resource to obtain a variety of secondary products including biofuels. Improving the performance of enzymatic hydrolysis of plant material with minimum costs and limiting the use of additional microbial biomass or hydrolytic enzymes directly influences competitiveness of these green biotechnological processes. In this study, we cloned and expressed a cellulase and two esterases recovered from environmental thermophilic soil bacterial communities and characterize their optimum activity conditions including the effect of several metal ions. Results showed that supplementing these hydrolytic reactions with Barium increases the activity of these extracellular hydrolytic enzymes. This observation represents a simple but major improvement to enhance the efficiency and competitiveness of this process within an increasingly important biotechnological sector.

  7. The Karlsruhe 4π barium fluoride detector

    International Nuclear Information System (INIS)

    Wisshak, K.; Guber, K.; Kaeppeler, F.; Krisch, J.; Mueller, H.; Rupp, G.; Voss, F.

    1989-12-01

    A new experimental approach has been implemented for accurate measurements of neutron capture cross sections in the energy range from 5 to 200 keV. The Karlsruhe 4π Barium Fluoride Detector consists of 42 crystals shaped as hexagonal and pentagonal truncated pyramids forming a spherical shell with 10 cm inner radius and 15 cm thickness. All crystals are supplied with reflector and photomultiplier, thus representing independent gamma-ray detectors. Each detector module covers the same solid angle with respect to a gamma-ray source located in the centre. The energy resolution of the 4π detector is 14% at 662 keV and 7% at 2.5 MeV gamma-ray energy, the overall time reslution is 500 ps and the peak efficiency 90% at 1 MeV. The detector allows to register capture cascades with 95% probability above a threshold energy of 2.5 MeV in the sum energy spectrum. Neutrons are produced via the 7 Li(p,n) 7 Be reaction using the pulsed proton beam of a Van de Graaff accelerator. The neutron spectrum can be taylored according to the experimental requirements in an energy range from 5 to 200 keV by choosing appropriate proton energies. A collimated neutron beam is passing through the detector and hits the sample in the centre. The energy of captured neutrons is determined via time of flight, the primary flight path being 77 cm. The combination of short primary flight path, a 10 cm inner radius of the spherical BaF 2 shell, and the low capture cross section of barium allows to discriminate background due to capture of sample scattered neutrons in the scintillator by time of flight, leaving part of the neutron energy range completely undisturbed. (orig./HSI) [de

  8. Solar Twins and the Barium Puzzle

    International Nuclear Information System (INIS)

    Reddy, Arumalla B. S.; Lambert, David L.

    2017-01-01

    Several abundance analyses of Galactic open clusters (OCs) have shown a tendency for Ba but not for other heavy elements (La−Sm) to increase sharply with decreasing age such that Ba was claimed to reach [Ba/Fe] ≃ +0.6 in the youngest clusters (ages < 100 Myr) rising from [Ba/Fe] = 0.00 dex in solar-age clusters. Within the formulation of the s -process, the difficulty to replicate higher Ba abundance and normal La−Sm abundances in young clusters is known as the barium puzzle. Here, we investigate the barium puzzle using extremely high-resolution and high signal-to-noise spectra of 24 solar twins and measured the heavy elements Ba, La, Ce, Nd, and Sm with a precision of 0.03 dex. We demonstrate that the enhanced Ba ii relative to La−Sm seen among solar twins, stellar associations, and OCs at young ages (<100 Myr) is unrelated to aspects of stellar nucleosynthesis but has resulted from overestimation of Ba by standard methods of LTE abundance analysis in which the microturbulence derived from the Fe lines formed deep in the photosphere is insufficient to represent the true line broadening imposed on Ba ii lines by the upper photospheric layers from where the Ba ii lines emerge. Because the young stars have relatively active photospheres, Ba overabundances most likely result from the adoption of a too low value of microturbulence in the spectrum synthesis of the strong Ba ii lines but the change of microturbulence in the upper photosphere has only a minor affect on La−Sm abundances measured from the weak lines.

  9. Solar Twins and the Barium Puzzle

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, Arumalla B. S.; Lambert, David L., E-mail: bala@astro.as.utexas.edu [W.J. McDonald Observatory and Department of Astronomy, The University of Texas at Austin, Austin, TX 78712-1205 (United States)

    2017-08-20

    Several abundance analyses of Galactic open clusters (OCs) have shown a tendency for Ba but not for other heavy elements (La−Sm) to increase sharply with decreasing age such that Ba was claimed to reach [Ba/Fe] ≃ +0.6 in the youngest clusters (ages < 100 Myr) rising from [Ba/Fe] = 0.00 dex in solar-age clusters. Within the formulation of the s -process, the difficulty to replicate higher Ba abundance and normal La−Sm abundances in young clusters is known as the barium puzzle. Here, we investigate the barium puzzle using extremely high-resolution and high signal-to-noise spectra of 24 solar twins and measured the heavy elements Ba, La, Ce, Nd, and Sm with a precision of 0.03 dex. We demonstrate that the enhanced Ba ii relative to La−Sm seen among solar twins, stellar associations, and OCs at young ages (<100 Myr) is unrelated to aspects of stellar nucleosynthesis but has resulted from overestimation of Ba by standard methods of LTE abundance analysis in which the microturbulence derived from the Fe lines formed deep in the photosphere is insufficient to represent the true line broadening imposed on Ba ii lines by the upper photospheric layers from where the Ba ii lines emerge. Because the young stars have relatively active photospheres, Ba overabundances most likely result from the adoption of a too low value of microturbulence in the spectrum synthesis of the strong Ba ii lines but the change of microturbulence in the upper photosphere has only a minor affect on La−Sm abundances measured from the weak lines.

  10. Chloride removal from vitrification offgas

    Energy Technology Data Exchange (ETDEWEB)

    Slaathaug, E.J. [Westinghouse Hanford Co., Richland, WA (United States)

    1995-06-01

    This study identified and investigated techniques of selectively purging chlorides from the low-level waste (LLW) vitrification process with the purge stream acceptable for burial on the Hanford Site. Chlorides will be present in high concentration in several individual feeds to the LLW Vitrification Plant. The chlorides are highly volatile in combustion type melters and are readily absorbed by wet scrubbing of the melter offgas. The Tank Waste Remediation System (TWRS) process flow sheets show that the resulting chloride rich scrub solution is recycled back to the melter. The chlorides must be purged from the recycle loop to prevent the buildup of excessively high chloride concentrations.

  11. Chloride removal from vitrification offgas

    International Nuclear Information System (INIS)

    Slaathaug, E.J.

    1995-01-01

    This study identified and investigated techniques of selectively purging chlorides from the low-level waste (LLW) vitrification process with the purge stream acceptable for burial on the Hanford Site. Chlorides will be present in high concentration in several individual feeds to the LLW Vitrification Plant. The chlorides are highly volatile in combustion type melters and are readily absorbed by wet scrubbing of the melter offgas. The Tank Waste Remediation System (TWRS) process flow sheets show that the resulting chloride rich scrub solution is recycled back to the melter. The chlorides must be purged from the recycle loop to prevent the buildup of excessively high chloride concentrations

  12. Polypyrrole–titanium(IV) doped iron(III) oxide nanocomposites: Synthesis, characterization with tunable electrical and electrochemical properties

    International Nuclear Information System (INIS)

    Nandi, Debabrata; Ghosh, Arup Kumar; Gupta, Kaushik; De, Amitabha; Sen, Pintu; Duttachowdhury, Ankan; Ghosh, Uday Chand

    2012-01-01

    Highlights: ► Synthesis and characterization of polymer nanocomposite based on titanium doped iron(III) oxide. ► Electrical conductivity increased 100 times in composite with respect to polymer. ► Electrochemical capacitance of polymer composites increased with nanooxide content. ► Thermal stability of the polymer enhanced with nano oxide content. -- Abstract: Titanium(IV)-doped synthetic nanostructured iron(III) oxide (NITO) and polypyrrole (PPy) nanocomposites was fabricated by in situ polymerization using FeCl 3 as initiator. The polymer nanocomposites (PNCs) and pure NITO were characterized by X-ray diffraction, Föurier transform infrared spectroscopy, scanning electron microscopy, electron dispersive X-ray spectroscopy, transmission electron microscopy, etc. Thermo gravimetric and differential thermal analyses showed the enhancement of thermal stability of PNCs than the pure polymer. Electrical conductivity of the PNCs had increased significantly from 0.793 × 10 −2 S/cm to 0.450 S/cm with respect to the PPy, and that had been explained by 3-dimensional variable range hopping (VRH) conduction mechanisms. In addition, the specific capacitance of PNCs had increased from 147 F/g to 176 F/g with increasing NITO content than that of pure NITO (26 F/g), presumably due to the growing of mesoporous structure with increasing NITO content in PNCs which reduced the charge transfer resistance significantly.

  13. Adsorption and transformation of selected human-used macrolide antibacterial agents with iron(III) and manganese(IV) oxides

    Energy Technology Data Exchange (ETDEWEB)

    Feitosa-Felizzola, Juliana [Laboratoire Chimie Provence, Aix-Marseille Universites-CNRS (UMR 6264), 3 place Victor Hugo, 13331 Marseille Cedex 3 (France); Hanna, Khalil [Laboratoire de Chimie Physique et Microbiologie pour l' Environnement, CNRS-Universite Henri Poincare-Nancy 1 (UMR 7564), 405 rue de Vandoeuvre, 54600 Villers-les-Nancy (France); Chiron, Serge [Laboratoire Chimie Provence, Aix-Marseille Universites-CNRS (UMR 6264), 3 place Victor Hugo, 13331 Marseille Cedex 3 (France)], E-mail: serge.chiron@univ-provence.fr

    2009-04-15

    The adsorption/transformation of two members (clarithromycin and roxithromycin) of the macrolide (ML) antibacterial agents on the surface of three environmental subsurface sorbents (clay, iron(III) and manganese(IV) oxy-hydroxides) was investigated. The adsorption fitted well to the Freundlich model with a high sorption capacity. Adsorption probably occurred through a surface complexation mechanism and was accompanied by slow degradation of the selected MLs. Transformation proceeded through two parallel pathways: a major pathway was the hydrolysis of the cladinose sugar, and to a lesser extent the hydrolysis of the lactone ring. A minor pathway was the N-dealkylation of the amino sugar. This study indicates that Fe(III) and Mn(IV) oxy-hydroxides in aquatic sediments may play an important role in the natural attenuation of MLs. Such an attenuation route yields a range of intermediates that might retain some of their biological activity. - Iron(III) and manganese(IV) oxy-hydroxides in aquatic sediments may play an important role in the natural attenuation of macrolide antibacterial agents.

  14. Adsorption and transformation of selected human-used macrolide antibacterial agents with iron(III) and manganese(IV) oxides

    International Nuclear Information System (INIS)

    Feitosa-Felizzola, Juliana; Hanna, Khalil; Chiron, Serge

    2009-01-01

    The adsorption/transformation of two members (clarithromycin and roxithromycin) of the macrolide (ML) antibacterial agents on the surface of three environmental subsurface sorbents (clay, iron(III) and manganese(IV) oxy-hydroxides) was investigated. The adsorption fitted well to the Freundlich model with a high sorption capacity. Adsorption probably occurred through a surface complexation mechanism and was accompanied by slow degradation of the selected MLs. Transformation proceeded through two parallel pathways: a major pathway was the hydrolysis of the cladinose sugar, and to a lesser extent the hydrolysis of the lactone ring. A minor pathway was the N-dealkylation of the amino sugar. This study indicates that Fe(III) and Mn(IV) oxy-hydroxides in aquatic sediments may play an important role in the natural attenuation of MLs. Such an attenuation route yields a range of intermediates that might retain some of their biological activity. - Iron(III) and manganese(IV) oxy-hydroxides in aquatic sediments may play an important role in the natural attenuation of macrolide antibacterial agents

  15. Barium ferrite nanoparticles prepared by self-propagating low ...

    Indian Academy of Sciences (India)

    Administrator

    Kubo et al 1982; Lucchini et al 1983), hydrothermal. (Barb et al 1986), microemulsion ... combustion route employing metal oxalate precursors. In search of a suitable ... heptahydrate/barium nitrate and oxalic acid were dis- solved in minimum ...

  16. Late changes in barium sulfate aspiration: HRCT features

    International Nuclear Information System (INIS)

    Voloudaki, A.; Ergazakis, N.; Gourtsoyiannis, N.

    2003-01-01

    Aspiration of barium sulfate occurs accidentally. Lung reaction is usually mild in the early phase due to inert character of the substance and long-term reactions or late toxicities are not expected. Little if any fibrotic response is speculated. We present a case with barium aspiration, studied by high-resolution computed tomography (HRCT) 1 year after the event, as late pulmonary sequelae studied by CT have not been described yet, to the best of our knowledge. The HRCT revealed thickened interlobular septa, subpleural lines, subpleural cysts, and centrilobular micronodules along with barium particles in a subpleural distribution. Those findings indicated that barium is capable of producing mild though silent clinically fibrosis. (orig.)

  17. Synthesis, photoluminescence and magnetic properties of barium vanadate nanoflowers

    International Nuclear Information System (INIS)

    Xu, Jing; Hu, Chenguo; Xi, Yi; Peng, Chen; Wan, Buyong; He, Xiaoshan

    2011-01-01

    Graphical abstract: The flower-shaped barium vanadate was obtained for the first time. The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. Research highlights: → In the paper, the flower-shaped barium vanadate were obtained for the first time. The CHM method used here is new and simple for preparation of barium vanadate. → The photoluminescence and magnetic properties of the barium vanadate nanoflowers were investigated at room temperature. The strong bluish-green emission was observed. → The ferromagnetic behavior of the barium vanadate nanoflowers was found with saturation magnetization of about 83.50 x 10 -3 emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10 -3 emu/g. → The mechanisms of PL and magnetic property of barium vanadate nanoflowers have been discussed. -- Abstract: The flower-shaped barium vanadate has been obtained by the composite hydroxide mediated (CHM) method from V 2 O 5 and BaCl 2 at 200 o C for 13 h. XRD and XPS spectrum of the as-synthesized sample indicate it is hexagonal Ba 3 V 2 O 8 with small amount of Ba 3 VO 4.8 coexistence. Scan electron microscope and transmission electron microscope display that the flower-shaped crystals are composed of nanosheets with thickness of ∼20 nm. The UV-visible spectrum shows that the barium vanadate sample has two optical gaps (3.85 eV and 3.12 eV). Photoluminescence spectrum of the barium vanadate flowers exhibits a visible light emission centered at 492 and 525 nm which might be attributed to VO 4 tetrahedron with T d symmetry in Ba 3 V 2 O 8 . The ferromagnetic behavior of the barium vanadate nanoflowers has been found with saturation magnetization of about 83.50 x 10 -3 emu/g, coercivity of 18.89 Oe and remnant magnetization of 4.63 x 10 -3 emu/g, which is mainly due to the presence of a non-orthovanadate phase with spin S = 1/2.

  18. The Effect of Temperature and Ionic Strength on the Oxidation of Iodide by Iron(III): A Clock Reaction Kinetic Study

    Science.gov (United States)

    Bauer, Jurica; Tomisic, Vladislav; Vrkljan, Petar B. A.

    2012-01-01

    A laboratory exercise has recently been reported in which the students use the initial rates method based on the clock reaction approach to deduce the rate law and propose a reaction mechanism for the oxidation of iodide by iron(III) ions. The same approach is used in the exercise proposed herein; the students determine the dependence of the…

  19. Mononuclear nonheme iron(III) complexes that show superoxide dismutase-like activity and antioxidant effects against menadione-mediated oxidative stress.

    Science.gov (United States)

    Hitomi, Yutaka; Iwamoto, Yuji; Kashida, Akihiro; Kodera, Masahito

    2015-05-21

    This communication describes the superoxide dismutase (SOD)-like activity of mononuclear iron(III) complexes with pentadentate monocarboxylamido ligands. The SOD activity can be controlled by the electronic nature of the substituent group on the ligand. The nitro-substituted complex showed clear cytoprotective activity against menadione-mediated oxidative stress in cultured cells.

  20. Lithium thionyl chloride battery

    Energy Technology Data Exchange (ETDEWEB)

    Saathoff, D.J.; Venkatasetty, H.V.

    1982-10-19

    The discharge rate and internal conductivity of electrochemical cell including a lithium anode, and a cathode and an electrolyte including LiAlCl4 and SOC2 is improved by the addition of an amount of a mixture containing AlCl3 and butyl pyridinium chloride.

  1. The medical sodium chloride

    International Nuclear Information System (INIS)

    Mirsaidov, U.M.

    2002-01-01

    In the institute was investigated the chemical composition of rock salt of some deposits of Tajikistan and was show the presence in it admixture of ions of Ca 2 + , Mg 2 + a nd SO 2 - a nd absence of heavy metals, ammonium salts, iron, potassium and arsenic. Was elaborated the fundamental instrument-technologic scheme of sodium chloride receiving

  2. Cost-effectiveness of barium enemas performed by radiographers

    International Nuclear Information System (INIS)

    Brown, Lorraine; Desai, Sharad

    2002-01-01

    AIM: To assess the cost-effectiveness of barium enemas performed by radiographers compared to those performed by consultant radiologists. METHOD: Prospective study of 200 barium enemas carried out by a senior radiographer and a consultant radiologist. The sample was a consecutive sample of adult out-patients over a 3-month period, with no exclusion. The length of time of the enema and the numbers and grades of staff involved in the procedure were recorded. This was translated into staffing costs using the appropriate pay scales. RESULTS: The barium enemas performed by the superintendent radiographer were more cost-effective than those performed by the consultant radiologist (1406 pounds for 100 radiographer-performed barium enemas compared to 1787 pounds for 100 carried out by the consultant radiologist). CONCLUSION: In terms of staffing costs, radiographers performing barium enemas not only liberates radiologist time, it is also a cost-effective method of providing an out-patient barium enema service. Brown, L. and Desai, S. (2002)

  3. A Stopped-Flow Kinetics Experiment for Advanced Undergraduate Laboratories: Formation of Iron(III) Thiocyannate

    Science.gov (United States)

    Clark, Charles R.

    1997-10-01

    A series of 15 stopped-flow kinetic experiments relating to the formation of iron(III)- thiocyanate at 25.0 °C and I = 1.0 M (NaClO4) is described. A methodology is given whereby solution preparation and data collection are able to be carried out within the time scale of a single laboratory period (3-4 h). Kinetic data are obtained using constant [SCN-], and at three H+ concentrations (0.10, 0.20, 0.30 M) for varying concentrations of Fe3+ (ca. 0.0025 - 0.020 M). Rate data (450 nm) are consistent with rate laws for the forward and reverse reactions: kf = (k1 + k2Ka1/[H+])[Fe3+] and kr = k-1 + k-2Ka2/[H+] respectively, with k1,k-1 corresponding to the rate constants for formation and decay of FeSCN2+, k2, k-2 to the rate constants for formation and decay of the FeSCN(OH)+ ion and Ka1,Ka2 to the acid dissociation constants (coordinated OH2 ionization) of Fe3+ and FeSCN2+. Using literature values for the latter two quantities ( Ka1 = 2.04 x 10-3 M, Ka2 = 6.5 x 10-5 M) allows values for the four rate constants to be obtained. A typical data set is analyzed to give k1 = 109(10) M-1s-1, k-1 = 0.79(0.10) s-1, k2= 8020(800) M-1s-1, k-2 = 2630(230) s-1. Absorbance change data for reaction (DeltaA) follow the expression: DeltaA = Alim.Kf.[Fe3+]/(1 + Kf.[Fe3+]), with Alim corresponding to the absorbance of fully formed FeSCN2+ (i.e. free SCN- absent) and Kf to the formation constant of this complex (value in the example 112(5) M-1, c.f. 138(29) M-1 from the kinetic data).

  4. Anastomotic stenosis of the descending colon caused by barium granuloma formation following barium peritonitis: report of a case.

    Science.gov (United States)

    Kitajima, Toshihiro; Tomizawa, Kenji; Hanaoka, Yutaka; Toda, Shigeo; Matoba, Shuichiro; Kuroyanagi, Hiroya; Oota, Yasunori

    2014-11-01

    Anastomotic stricture reportedly often recurs following barium peritonitis, regardless of whether the anastomotic diameter is initially sufficient. However, the causes of repetitive stricture have not been clarified. We report a case that suggests the pathophysiology of recurrent anastomotic strictures following barium peritonitis. The patient was a 39-year-old Japanese man with idiopathic perforation of the descending colon after undergoing an upper gastrointestinal barium contrast study. After emergency peritoneal lavage and diverting colostomy, created using the perforated region, the patient recovered uneventfully and 3 months later, the colostomy was closed and the perforated colon was resected. However, 7 months after colostomy closure, abdominal distention gradually developed, and colonoscopy revealed an anastomotic stricture. The patient was referred to our hospital where he underwent resection of the anastomotic stricture. The surgical specimen exhibited barium granulomas not only in the subserosa of the entire specimen, but also in the submucosa and lamina propria localized in the anastomotic site. These findings suggest that barium was embedded in the submucosa and lamina propria with manipulation of the stapled anastomosis and that the barium trapped in the anastomotic site caused persistent inflammation, resulting in an anastomotic stricture.

  5. Electrooptic and piezoelectric measurements in photorefractive barium titanate and strontium barium niobate

    International Nuclear Information System (INIS)

    Ducharme, S.; Feinberg, J.; Neurgaonkar, R.R.

    1987-01-01

    The authors measured the low-frequency (''unclamped'') electrooptic and piezoelectric coefficients in undoped BaTiO/sub 3/ and Sr/sub x/Ba/sub 1-x/Nb/sub 2/O/sub 6/ (chi - 0.61) crystals using interferometric techniques. The contribution of the piezoelectric effect to the Pockels measurement is discussed. For an applied ac electric field in the range 0.1-200 V/cm, the electrooptic and piezoelectric effects are linear in the magnitude of of the applied field and independent of its frequency in the range of 10 Hz-100 kHz. The unclamped electrooptic coefficients of poled BaTiO/sub 3/ single crystals are r/sub 13/ = 19.5 +- 1 pm/V and r/sub 33/ = 97 +- 7 pm/V, and for strontium barium niobate are r/sub 13/ = 47 +- 5 pm/V and r/sub 33/ = 235 +- 21 pm/V, all measured at a wavelength of 514.5 nm and at T = 23 0 C. For the barium titanate samples the measured Pockels coefficient r/sub c/ identical to r/sub 33/ - (n/sub 1//n/sub 3/)/sup 3/r/sub 13/ = 79 +- 6 pm/V in good agreement with the value r/sub c/ = 76 +- 7 pm/V computed from the above values of r/sub 13/ and r/sub 33/, where n/sub 1/ and n/sub 3/ are the ordinary and extraordinary indexes of refraction, respectively. The measured piezoelectric coefficient is d/sub 23/ = +28.7 +- 2 pm/V for barium titanate, and is d/sub 23/ = +24.6 +- 2 pm/V for strontium barium niobate. They also measured the photoreflective coupling of two optical beams in the crystals, and they show that the dependence of the coupling strength on beam polarization is in fair agreement with the measured values of the Pockels coefficients

  6. Barium low concentration determination in solutions using X rays energy spectrometry

    International Nuclear Information System (INIS)

    Barbosa, Joao Batista Santos; Pereira, Jose dos Santos Jorge

    1999-01-01

    This work was proposed to establish an analytical methodology for barium determination in samples from the Waste Supervision of CDTN. Barium is the focus here because it has the same chemical behaviour as radium. Therefore, barium can replace it as an inactive tracer in contention matrix studies. The methodology is made up of two phases; physical concentration and barium determination by an Energy Dispersive Spectrometer using an Am 241 photon excitation system. A very good set of results is found when Am 241 is used in fluorescing barium atoms. This fact, in addition to the physical concentration process, allows to detect up 12 ppb of elementary barium. (author)

  7. The efficacy of steroids for postoperative persistent inflammatory reaction in a patient with barium peritonitis: A case report

    Directory of Open Access Journals (Sweden)

    Hirofumi Kojima

    2017-01-01

    Conclusion: Residual barium in the intraperitoneal cavity causes persistent inflammatory reaction in patients with barium peritonitis. The use of steroids is effective for postoperative persistent inflammation due to the residual barium.

  8. Solid solution barium–strontium chlorides with tunable ammonia desorption properties and superior storage capacity

    Energy Technology Data Exchange (ETDEWEB)

    Bialy, Agata [Amminex Emissions Technology A/S, Gladsaxevej 363, 2860 Soeborg (Denmark); Jensen, Peter B. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Center for Atomic-scale Materials Design, Department of Physics, Technical University of Denmark, Fysikvej 311, DK-2800 Kgs. Lyngby (Denmark); Blanchard, Didier [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Vegge, Tejs, E-mail: teve@dtu.dk [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Quaade, Ulrich J., E-mail: ujq@amminex.com [Amminex Emissions Technology A/S, Gladsaxevej 363, 2860 Soeborg (Denmark)

    2015-01-15

    Metal halide ammines are very attractive materials for ammonia absorption and storage—applications where the practically accessible or usable gravimetric and volumetric storage densities are of critical importance. Here we present, that by combining advanced computational materials prediction with spray drying and in situ thermogravimetric and structural characterization, we synthesize a range of new, stable barium-strontium chloride solid solutions with superior ammonia storage densities. By tuning the barium/strontium ratio, different crystallographic phases and compositions can be obtained with different ammonia ab- and desorption properties. In particular it is shown, that in the molar range of 35–50% barium and 65–50% strontium, stable materials can be produced with a practically usable ammonia density (both volumetric and gravimetric) that is higher than any of the pure metal halides, and with a practically accessible volumetric ammonia densities in excess of 99% of liquid ammonia. - Graphical abstract: Thermal desorption curves of ammonia from Ba{sub x}Sr{sub (1−x)}Cl{sub 2} mixtures with x equal to 0.125, 0.25 and 0.5 and atomic structure of Sr(NH{sub 3}){sub 8}Cl{sub 2}. - Highlights: • Solid solutions of strontium and barium chloride were synthesized by spray drying. • Adjusting molar ratios led to different crystallographic phases and compositions. • Different molar ratios led to different ammonia ab-/desorption properties. • 35–50 mol% BaCl{sub 2} in SrCl{sub 2} yields higher ammonia density than any other metal halide. • DFT calculations can be used to predict properties of the mixtures.

  9. High H⁻ ionic conductivity in barium hydride.

    Science.gov (United States)

    Verbraeken, Maarten C; Cheung, Chaksum; Suard, Emmanuelle; Irvine, John T S

    2015-01-01

    With hydrogen being seen as a key renewable energy vector, the search for materials exhibiting fast hydrogen transport becomes ever more important. Not only do hydrogen storage materials require high mobility of hydrogen in the solid state, but the efficiency of electrochemical devices is also largely determined by fast ionic transport. Although the heavy alkaline-earth hydrides are of limited interest for their hydrogen storage potential, owing to low gravimetric densities, their ionic nature may prove useful in new electrochemical applications, especially as an ionically conducting electrolyte material. Here we show that barium hydride shows fast pure ionic transport of hydride ions (H(-)) in the high-temperature, high-symmetry phase. Although some conductivity studies have been reported on related materials previously, the nature of the charge carriers has not been determined. BaH2 gives rise to hydride ion conductivity of 0.2 S cm(-1) at 630 °C. This is an order of magnitude larger than that of state-of-the-art proton-conducting perovskites or oxide ion conductors at this temperature. These results suggest that the alkaline-earth hydrides form an important new family of materials, with potential use in a number of applications, such as separation membranes, electrochemical reactors and so on.

  10. Barium enema in frail elderly patients.

    Science.gov (United States)

    Segal, R; Khahil, A; Leibovitz, A; Gil, I; Annuar, M; Habot, B

    2000-01-01

    Barium enema (BE) examinations for the investigation of suspected colonic disease are often unsuccessful in elderly patients. The purpose of this study was to evaluate the success rate of BE in hospitalized frail elderly patients. Four hundred and seventy-two elderly patients hospitalized for different reasons underwent BE examinations. The medical charts and radiological reports were retrospectively reviewed. One hundred and ninety-two (41%) BE examinations were considered inadequate; mostly (32%) because of inappropriate preparation. Sixty-seven patients (14%) were not cooperative and could not retain the contrast material, and in 25 patients (5%), the examination failed due to both these reasons. The characteristics associated with unsuccessful BE examination were the mean number of medical problems (p < 0.001), the mean number of scheduled medications (p < 0.05) and in particular the long-term use of laxatives (p < 0.01) or antiparkinsonian drugs (p < 0.01). Of great significance in predicting an inadequate BE were the patient's functional status (p < 0.001) and the presence of dementia (p < 0.001). The high percentage of unsuccessful BEs in the frail elderly suggests that clinicians should carefully consider the need for that examination in these patients. We suggest that only in patients where there is a clear suspicion of a bleeding or obstructing tumor should a BE examination be performed, and even in these cases, colonoscopy or CT may be preferable as the initial examination in the frail elderly. Copyright 2000 S. Karger AG, Basel

  11. Optical properties of calcium barium niobate

    Energy Technology Data Exchange (ETDEWEB)

    Heine, Urs; Betzler, Klaus [Department of Physics, University of Osnabrueck (Germany); Burianek, Manfred; Muehlberg, Manfred [Institute of Crystallography, University of Cologne (Germany)

    2010-07-01

    We report on optical measurements on the novel tungsten bronze type calcium barium niobate. [001]-oriented transparent and colorless single crystals were grown by the Czochralski method with dimensions of 12 mm in diameter and about 80 mm in length. With its relatively high Curie temperature of about 538 K for the congruently melting composition of 28.1 mole% calcium and its high nonlinear coefficients, CBN is a promising material for future applications. Recent experiments revealed, that the application of an external electric field of several kV/cm to CBN at room temperature leads to an increasing opacity of the sample. This might be a drawback considering the future usability of CBN in optical systems. We present investigations on the transmittance behaviour of CBN under external electric fields, demonstrating the erasement of the clouding without affecting the polarization. Experiments have been performed at temperatures ranging from room temperature to approximately 480 K. When heating up the sample, its colorless appearance changes to a light yellow, which can be attributed to a shift of the band edge to longer wavelengths with increasing temperature. To further investigate the transmittance properties of CBN, measurements of the band edge under various temperatures up to the ferroelectric phase transition have been performed.

  12. Effectiveness of therapeutic barium enema for diverticular hemorrhage.

    Science.gov (United States)

    Matsuura, Mizue; Inamori, Masahiko; Nakajima, Atsushi; Komiya, Yasuhiko; Inoh, Yumi; Kawasima, Keigo; Naitoh, Mai; Fujita, Yuji; Eduka, Akiko; Kanazawa, Noriyoshi; Uchiyama, Shiori; Tani, Rie; Kawana, Kennichi; Ohtani, Setsuya; Nagase, Hajime

    2015-05-14

    To evaluate the effectiveness of barium impaction therapy for patients with colonic diverticular bleeding. We reviewed the clinical charts of patients in whom therapeutic barium enema was performed for the control of diverticular bleeding between August 2010 and March 2012 at Yokohama Rosai Hospital. Twenty patients were included in the review, consisting of 14 men and 6 women. The median age of the patients was 73.5 years. The duration of the follow-up period ranged from 1 to 19 mo (median: 9.8 mo). Among the 20 patients were 11 patients who required the procedure for re-bleeding during hospitalization, 6 patients who required it for re-bleeding that developed after the patient left the hospital, and 3 patients who required the procedure for the prevention of re-bleeding. Barium (concentration: 150 w%/v%) was administered per the rectum, and the leading edge of the contrast medium was followed up to the cecum by fluoroscopy. After confirmation that the ascending colon and cecum were filled with barium, the enema tube was withdrawn, and the patient's position was changed every 20 min for 3 h. Twelve patients remained free of re-bleeding during the follow-up period (range: 1-19 mo) after the therapeutic barium enema, including 9 men and 3 women with a median age of 72.0 years. Re-bleeding occurred in 8 patients including 5 men and 3 women with a median age of 68.5 years: 4 developed early re-bleeding, defined as re-bleeding that occurs within one week after the procedure, and the remaining 4 developed late re-bleeding. The DFI (disease-free interval) decreased 0.4 for 12 mo. Only one patient developed a complication from therapeutic barium enema (colonic perforation). Therapeutic barium enema is effective for the control of diverticular hemorrhage in cases where the active bleeding site cannot be identified by colonoscopy.

  13. The diagnostic value of barium enema in acute appendicitis

    International Nuclear Information System (INIS)

    Kim, Yong Ga; Chung, Duck Soo; Kim, Ok Dong

    1986-01-01

    Acute appendicitis is the most common acute surgical condition of the abdomen. When the clinical presentation is atypical, barium enema has proven to be safe and useful in confirming the diagnosis and reducing the negative surgical exploration. However, the performance of barium enema in acute appendicitis has known contraindication primarily because of fear of leakage by perforation of the inflamed appendix. This study using barium enema as a diagnostic aid in acute appendicitis with atypical clinical presentation was performed to further support the previously noted efficacy and safety of this procedure. The results were as followings: 1. In case of acute appendicitis with atypical clinical presentation, the use of barium enema as a diagnostic aid increased the accuracy of diagnosis and decreased the negative surgical exploration. In women between 11 to 50 years old age, especially, it played important role differentiating appendicitis from nonsurgical acute abdomen. 2. The results of the study were 92.31% in sensitivity, 7.69% in false positive, 6.9% in false negative, and 10.26% in negative appendectomy. 3. None of case of leakage of barium by perforation of the inflamed appendix was noted, therefore, barium enema was thought to be safe as a diagnostic aid in acute appendicitis. 4. A simple partial or non filling of appendix without other associated positive finding could not exclude appendicitis, therefore, close clinical observation was necessary. 5. The positive findings of barium enema and their sensitivity were as followings: 1. Non filling of appendix: 90% 2. Partial filling of appendix: 91.7% 3. Displacement or a local impression on terminal ileum: 100%

  14. Economically attractive route for the preparation of high quality magnetic nanoparticles by the thermal decomposition of iron(III) acetylacetonate.

    Science.gov (United States)

    Effenberger, Fernando B; Couto, Ricardo A; Kiyohara, Pedro K; Machado, Giovanna; Masunaga, Sueli H; Jardim, Renato F; Rossi, Liane M

    2017-03-17

    The thermal decomposition (TD) methods are among the most successful in obtaining magnetic nanoparticles with a high degree of control of size and narrow particle size distribution. Here we investigated the TD of iron(III) acetylacetonate in the presence of oleic acid, oleylamine, and a series of alcohols in order to disclose their role and also investigate economically attractive alternatives for the synthesis of iron oxide nanoparticles without compromising their size and shape control. We have found that some affordable and reasonably less priced alcohols, such as 1,2-octanediol and cyclohexanol, may replace the commonly used and expensive 1,2-hexadecanediol, providing an economically attractive route for the synthesis of high quality magnetic nanoparticles. The relative cost for the preparation of Fe 3 O 4 NPs is reduced to only 21% and 9% of the original cost when using 1,2-octanediol and cyclohexanol, respectively.

  15. Lithium, rubidium and cesium ion removal using potassium iron(III) hexacyanoferrate(II) supported on polymethylmethacrylate

    International Nuclear Information System (INIS)

    Shabana Taj; Din Muhammad; Ashraf Chaudhry, M.; Muhammad Mazhar

    2011-01-01

    Potassium iron(III) hexacyanoferrate(II) supported on poly methyl methacrylate, has been developed and investigated for the removal of lithium, rubidium and cesium ions. The material is capable of sorbing maximum quantities of these ions from 5.0, 2.5 and 4.5 M HNO 3 solutions respectively. Sorption studies, conducted individually for each metal ion, under optimized conditions, demonstrated that it was predominantly physisorption in the case of lithium ion while shifting to chemisorption with increasing ionic size. Distribution coefficient (K d ) values followed the order Cs + > Rb + > Li + at low concentrations of metal ions. Following these findings Cs + can preferably be removed from 1.5 to 5 M HNO 3 nuclear waste solutions. (author)

  16. Freeze cast porous barium titanate for enhanced piezoelectric energy harvesting

    Science.gov (United States)

    Roscow, J. I.; Zhang, Y.; Kraśny, M. J.; Lewis, R. W. C.; Taylor, J.; Bowen, C. R.

    2018-06-01

    Energy harvesting is an important developing technology for a new generation of self-powered sensor networks. This paper demonstrates the significant improvement in the piezoelectric energy harvesting performance of barium titanate by forming highly aligned porosity using freeze casting. Firstly, a finite element model demonstrating the effect of pore morphology and angle with respect to poling field on the poling behaviour of porous ferroelectrics was developed. A second model was then developed to understand the influence of microstructure-property relationships on the poling behaviour of porous freeze cast ferroelectric materials and their resultant piezoelectric and energy harvesting properties. To compare with model predictions, porous barium titanate was fabricated using freeze casting to form highly aligned microstructures with excellent longitudinal piezoelectric strain coefficients, d 33. The freeze cast barium titanate with 45 vol.% porosity had a d 33  =  134.5 pC N‑1 compared to d 33  =  144.5 pC N‑1 for dense barium titanate. The d 33 coefficients of the freeze cast materials were also higher than materials with uniformly distributed spherical porosity due to improved poling of the aligned microstructures, as predicted by the models. Both model and experimental data indicated that introducing porosity provides a large reduction in the permittivity () of barium titanate, which leads to a substantial increase in energy harvesting figure of merit, , with a maximum of 3.79 pm2 N‑1 for barium titanate with 45 vol.% porosity, compared to only 1.40 pm2 N‑1 for dense barium titanate. Dense and porous barium titanate materials were then used to harvest energy from a mechanical excitation by rectification and storage of the piezoelectric charge on a capacitor. The porous barium titanate charged the capacitor to a voltage of 234 mV compared to 96 mV for the dense material, indicating a 2.4-fold increase that was similar to that

  17. Fabry-Perot measurements of barium temperature in fluorescent lamps

    International Nuclear Information System (INIS)

    Hadrath, S; Garner, R

    2010-01-01

    A scanning Fabry-Perot interferometer (FPI) is used to determine the temperature of barium atoms that are liberated from the electrodes of fluorescent lamps during their steady-state operation. Barium, a constituent of the work function lowering emitter material that is placed on the tungsten coil that forms the electrode, is liberated primarily by evaporation from the hot (∼1300 K) thermionic electrode. However, there may be situations or modes of operation in which barium is, in addition, sputtered, a condition which may lead to increased end-darkening, shortened life and increased mercury consumption in the lamp. Using the FPI diagnostic, the occurrence of sputtering is inferred when barium temperatures are much greater than the electrode temperature. The FPI diagnostic senses resonance radiation (λ = 553 nm) emitted by barium atoms excited in the low pressure discharge environment, and infers temperature from the Doppler broadened linewidth. The diagnostic has proven to be successful in a number of situations. Measurements have been made on rare gas discharges and on Hg-argon discharges for different discharge currents, gas pressures and auxiliary coil currents. Measurements are phase resolved for ac-driven discharges.

  18. Air (CO2) double-contrast barium enteroclysis.

    Science.gov (United States)

    Maglinte, Dean D T; Kohli, Marc D; Romano, Stefania; Lappas, John C

    2009-09-01

    In the 1980s and 1990s in North America and Europe, air (CO(2)) double-contrast barium enteroclysis took a back seat to biphasic methylcellulose double-contrast enteroclysis in the investigation of small-bowel diseases. The widespread application of capsule endoscopy in the 21st century has identified a number of limitations of radiologic examinations in the investigation of mucosal diseases of the small intestine. Evidence-based studies comparing barium, computed tomographic (CT), and magnetic resonance (MR) enteroclysis have shown that in spite of improvements in small-bowel examination methods using CT and MR, barium examinations remain superior in the depiction of mucosal abnormalities, particularly the apthoid lesions of early Crohn disease. Barium small-bowel examinations have been recommended in the patient with a negative CT or MR enteroclysis study where the pretest probability of Crohn disease is high. A recent prospective comparison of methylcellulose double-contrast barium enteroclysis to capsule endoscopy with review of the literature has shown that air enteroclysis depicts mucosal details better than does methylcellulose double-contrast enteroclysis because of the "washout" effect of methylcellulose on superficial mucosal features. Recent articles have shown that air enteroclysis compares favorably with wireless capsule endoscopy and double-balloon endoscopy in the diagnosis of mucosal abnormalities of the small bowel. This article describes the authors' technique of performing air double-contrast enteroclysis, its clinical indications, and its pitfalls.

  19. Creating unstable velocity-space distributions with barium injections

    International Nuclear Information System (INIS)

    Pongratz, M.B.

    1983-01-01

    Large Debye lengths relative to detector dimensions and the absence of confining walls makes space an attractive laboratory for studying fundamental theories of plasma instabilities. However, natural space plasmas are rarely found displaced from equilibrium enough to permit isolation and diagnosis of the controlling parameters and driving conditions. Furthermore, any plasma or field response to the departure from equilibrium can be masked by noise in the natural system. Active experiments provide a technique for addressing the chicken or egg dilemma. Early thermite barium releases were generally conducted at low altitudes from sounding rockets to trace electric fields passively or to study configuration-space instabilities. One can also study velocity-space instabilities with barium releases. Neutral barium vapor releases wherein a typical speed greatly exceeds the thermal speed can be used to produce barium ion velocity-space distributions that should be subject to a number of microinstabilities. We examine the ion velocity-space distributions resulting from barium injections from orbiting spacecraft and shaped-charges

  20. Barium Depletion in the NSTAR Discharge Cathode After 30,000 Hours of Operation

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2010-01-01

    Dispenser hollow cathodes rely on a consumable supply of barium released by impregnant materials in the pores of a tungsten matrix to maintain a low work function surface. Examinations of cathode inserts from long duration ion engine tests show deposits of tungsten at the downstream end that appear to block the flow of barium from the interior. In addition, a numerical model of barium transport in the insert plasma indicates that the barium partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant barium-producing reaction, and it was postulated previously that this would suppress barium loss in the upstream part of the insert. New measurements of the depth of barium depletion from a cathode insert operated for 30,352 hours reveal that barium loss is confined to a narrow region near the downstream end, confirming this hypothesis.

  1. Controlling Barium Sulphate Scale Deposition Problems in an unbleached Kraft Paper Mill

    CSIR Research Space (South Africa)

    Sithole, Bruce

    2015-06-01

    Full Text Available Troubleshooting of scale deposits and defects in paper samples showed that the problem was caused by barium sulphate and calcium sulphate scales. However, it was ascertained that barium sulphate was more of a concern than calcium sulphate...

  2. Selectivity in biomineralization of barium and strontium.

    Science.gov (United States)

    Krejci, Minna R; Wasserman, Brian; Finney, Lydia; McNulty, Ian; Legnini, Daniel; Vogt, Stefan; Joester, Derk

    2011-11-01

    The desmid green alga Closterium moniliferum belongs to a small number of organisms that form barite (BaSO(4)) or celestite (SrSO(4)) biominerals. The ability to sequester Sr in the presence of an excess of Ca is of considerable interest for the remediation of (90)Sr from the environment and nuclear waste. While most cells dynamically regulate the concentration of the second messenger Ca(2+) in the cytosol and various organelles, transport proteins rarely discriminate strongly between Ca, Sr, and Ba. Herein, we investigate how these ions are trafficked in C. moniliferum and how precipitation of (Ba,Sr)SO(4) crystals occurs in the terminal vacuoles. Towards this goal, we simultaneously visualize intracellular dynamics of multiple elements using X-ray fluorescence microscopy (XFM) of cryo-fixed/freeze-dried samples. We correlate the resulting elemental maps with ultrastructural information gleaned from freeze-fracture cryo-SEM of frozen-hydrated cells and use micro X-ray absorption near edge structure (micro-XANES) to determine sulfur speciation. We find that the kinetics of Sr uptake and efflux depend on external Ca concentrations, and Sr, Ba, and Ca show similar intracellular localization. A highly ion-selective cross-membrane transport step is not evident. Based on elevated levels of sulfate detected in the terminal vacuoles, we propose a "sulfate trap" model, where the presence of dissolved barium leads to preferential precipitation of (Ba,Sr)SO(4) due to its low solubility relative to SrSO(4) and CaSO(4). Engineering the sulfate concentration in the vacuole may thus be the most direct way to increase the Sr sequestered per cell, an important consideration in using desmids for phytoremediation of (90)Sr. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Occupational doses in pediatric barium meal procedures

    International Nuclear Information System (INIS)

    Filipov, D.; Schelin, H.R.; Denyak, V.; Legnani, A.; Ledesma, J.A.; Paschuk, S.A.; Sauzen, J.; Yagui, A.; Hoff, G.; Khoury, H.J.

    2015-01-01

    Ionizing radiation has become an indispensable tool when it comes to diagnosis and therapy. However, its use should happen in a rational manner, taking into account the risks to which the staff is being exposed. Barium meal (BM), or upper gastrointestinal (GI) studies, using fluoroscopy, are widely used for gastroesophageal reflux disease diagnostic in children and professionals are required to stay inside the examination room to position and immobilize pediatric patients during the procedure. Therefore, it is very important that proffessionals strictly follow the technical standards of radiation protection. According to the ICRP and the NCRP recommendations, the annual limit equivalent doses for eyes, thyroid and hands are, espectively, 20 mSv, 150 mSv and 500 mSv. Based on those data, the aim of the current study is to estimate the annual equivalent dose for eyes, thyroid and hands of professionals who perform BM procedures in children. This was done using properly package LiF:Mg,Cu,P thermoluminescent dosimeters in 37 procedures; 2 pairs were positioned near each staff´s eye, 2 pairs on each professional´s neck (on and under the lead protector) and 2 pairs on both staff´s hands. The range of the estimative annual equivalent doses, for eyes, thyroid and hands, are, respectively: 14 – 36 mSv, 7 – 22 mSv and 14 – 58 mSv. Only the closest staff to the patient exceeded the annual equivalent doses in the eyes (around 80% higher than the limit set by ICRP). However, the results from this study, for hands and thyroid, compared to similar studies, show higher values. Therefore, the optimization implementation is necessary, so that the radiation levels can be reduced. (authors)

  4. Fabrication and properties of yttrium doped barium titanate film by RF sputtering

    International Nuclear Information System (INIS)

    Igarashi, H.; Yuasa, M.; Okazaki, K.

    1985-01-01

    Semiconductive barium titanate films were fabricated by RF sputtering on fused quartz, alumina and barium titanate ceramic substrates using barium titanate ceramic with a small amount of yttria as a target. The films on the barium titanate substrates turned blue color and showed a small PTC effect by heat-treating at 1000 0 C in the air after deposition at the substrate temperature of 600 0 C

  5. Corrosion potentials of hafnium in molten alkaline-earth metal chlorides

    International Nuclear Information System (INIS)

    Kovalik, O.Yu.; Tkhaj, V.D.

    2000-01-01

    Corrosion potentials of hafnium in molten calcium, strontium and barium chlorides are measured and their temperature dependences are determined. It is stated that the corrosion potential of hafnium becomes more electropositive with an increase of the environment temperature. If the temperature is the same the potential shifts to the interval of more electronegative values in the row of CaCl 2 , SrCl 2 , BaCl 2 which corresponds to a lesser corrosion rate in environments positioned from left to right. the comparison of hafnium corrosion potentials with previously measured values for titanium and zirconium shows that a metal activity decrease results in a more electronegative corrosion potential [ru

  6. TV observations of the Barium-GEOS ion jet experiment

    International Nuclear Information System (INIS)

    Hapgood, M.A.; Collin, H.L.; Rothwell, P.

    1980-01-01

    The barium jet released by the Barium-GEOS rocket was observed by low light television cameras at Skibotn, Norway and Esrange, Sweden. The release produced a single well-defined jet containing barium ions with initial velocities between 7 and 12 km s -1 systematically slower than the velocities reported in previous experiments. Accurate data on the motion of the jet has been obtained for the first two minutes after release (up to a height of 2000 km). The orientation of the jet was close to that of an IGRF1975 model field line but was significantly different from that predicted by the Barraclough and Olson field model. The motion of the jet across the field lines was southwards with a velocity of about 150 m s -1 . (Auth.)

  7. Barium-borate-flyash glasses: As radiation shielding materials

    International Nuclear Information System (INIS)

    Singh, Sukhpal; Kumar, Ashok; Singh, Devinder; Thind, Kulwant Singh; Mudahar, Gurmel S.

    2008-01-01

    The attenuation coefficients of barium-borate-flyash glasses have been measured for γ-ray photon energies of 356, 662, 1173 and 1332 keV using narrow beam transmission geometry. The photon beam was highly collimated and overall scatter acceptance angle was less than 3 o . Our results have an uncertainty of less than 3%. These coefficients were then used to obtain the values of mean free path (mfp), effective atomic number and electron density. Good agreements have been observed between experimental and theoretical values of these parameters. From the studies of the obtained results it is reported here that from the shielding point of view the barium-borate-flyash glasses are better shields to γ-radiations in comparison to the standard radiation shielding concretes and also to the ordinary barium-borate glasses

  8. Barium titanate thick films prepared by screen printing technique

    Directory of Open Access Journals (Sweden)

    Mirjana M. Vijatović

    2010-06-01

    Full Text Available The barium titanate (BaTiO3 thick films were prepared by screen printing technique using powders obtained by soft chemical route, modified Pechini process. Three different barium titanate powders were prepared: i pure, ii doped with lanthanum and iii doped with antimony. Pastes for screen printing were prepared using previously obtained powders. The thick films were deposited onto Al2O3 substrates and fired at 850°C together with electrode material (silver/palladium in the moving belt furnace in the air atmosphere. Measurements of thickness and roughness of barium titanate thick films were performed. The electrical properties of thick films such as dielectric constant, dielectric losses, Curie temperature, hysteresis loop were reported. The influence of different factors on electrical properties values was analyzed.

  9. Diagnostic role of barium enema in carcinoma rectum

    International Nuclear Information System (INIS)

    Asghar, M.

    2003-01-01

    Objective: The main aim of this barium enema study was to evaluate its role in patients suspected to have rectal pathologies with complaints of change in bowel habit, anorexia/weight loss, bleeding per rectum and acute/sub-acute colonic obstruction. Results: barium enema study as screening test for colo-rectal carcinoma was undertaken. Contrast outlined the colonic growth in 35 cases, out of which the cases of carcinoma colon were 24 including 13 patients suffering from carcinoma rectum. The percentage of carcinoma colon to total colonic growth was 68% while, carcinoma rectum to total carcinoma colon was 54%. Conclusion: On the basis of these investigations, it is concluded that patient's compliance is important factor in the early detection of colonic neoplasia. Though results of colonoscopy are more reliable but in practice, barium enema (double contrast) is performed initially to outline the lesion and then colonoscopy for biopsy purpose. (author)

  10. Gastrointestinal tract wall visualization and distention during abdominal and pelvic multidetector CT with a neutral barium sulphate suspension: comparison with positive barium sulphate suspension and with water.

    Science.gov (United States)

    Oliva, M R; Erturk, S M; Ichikawa, T; Rocha, T; Ros, P R; Silverman, S G; Mortele, K J

    2012-01-01

    When examining patients with contrast-enhanced multidetector-row CT, we determined if the stomach and small bowel were visualized and distended better with a neutral barium sulphate suspension than with positive barium sulphate suspension or water. After obtaining approval from our institutional review board, 156 patients (women: 84; mean age: 54 yrs) with no history of gastrointestinal tract disease were randomized prospectively to receive orally either 900 ml of neutral (0.1% w/v) barium sulphate suspension (n = 53), 900 ml of positive (2.1% w/v) barium sulphate suspension (n = 53), or 900 ml of water (n = 50), prior to undergoing contrast-enhanced abdominal and pelvic multidetector-row CT. Two independent radiologists evaluated the stomach, and small bowel, for luminal distension and wall visualization, using a five point scale. Results were compared using Kruskal-Wallis and Mann-Whitney U tests. The walls of the stomach, and small bowel were visualized better in patients who were administered neutral barium sulphate suspension than those who were administered either positive barium sulphate suspension (p barium sulphate suspension, the stomach and small bowel were distended better compared to patients administered water (p barium sulphate suspension (p contrast-enhanced abdominal and pelvic multidetector-row CT, orally administered neutral barium sulphate suspension allows the gastrointestinal tract to be visualized and distended better than either positive barium sulphate suspension, or water.

  11. Cloud point extraction of iron(III) and vanadium(V) using 8-quinolinol derivatives and Triton X-100 and determination of 10(-7)moldm(-3) level iron(III) in riverine water reference by a graphite furnace atomic absorption spectroscopy.

    Science.gov (United States)

    Ohashi, Akira; Ito, Hiromi; Kanai, Chikako; Imura, Hisanori; Ohashi, Kousaburo

    2005-01-30

    The cloud point extraction behavior of iron(III) and vanadium(V) using 8-quinolinol derivatives (HA) such as 8-quinolinol (HQ), 2-methyl-8-quinolinol (HMQ), 5-butyloxymethyl-8-quinolinol (HO(4)Q), 5-hexyloxymethyl-8-quinolinol (HO(6)Q), and 2-methyl-5-octyloxymethyl-8-quinolinol (HMO(8)Q) and Triton X-100 solution was investigated. Iron(III) was extracted with HA and 4% (v/v) Triton X-100 in the pH range of 1.70-5.44. Above pH 4.0, more than 95% of iron(III) was extracted with HQ, HMQ, and HMO(8)Q. Vanadium(V) was also extracted with HA and 4% (v/v) Triton X-100 in the pH range of 2.07-5.00, and the extractability increased in the following order of HMQ HQ cloud point extraction was applied to the determination of iron(III) in the riverine water reference by a graphite furnace atomic absorption spectroscopy. When 1.25 x 10(-3)M HMQ and 1% (v/v) Triton X-100 were used, the found values showed a good agreement with the certified ones within the 2% of the R.S.D. Moreover, the effect of an alkyl group on the solubility of 5-alkyloxymethyl-8-quinolinol and 2-methyl-5-alkyloxymethyl-8-quinolinol in 4% (v/v) Triton X-100 at 25 degrees C was also investigated.

  12. 21 CFR 201.304 - Tannic acid and barium enema preparations.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Tannic acid and barium enema preparations. 201.304... Tannic acid and barium enema preparations. (a) It has become a widespread practice for tannic acid to be added to barium enemas to improve X-ray pictures. Tannic acid is capable of causing diminished liver...

  13. 49 CFR 173.182 - Barium azide-50 percent or more water wet.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Barium azide-50 percent or more water wet. 173.182 Section 173.182 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... Class 1 and Class 7 § 173.182 Barium azide—50 percent or more water wet. Barium azide—50 percent or more...

  14. 40 CFR 721.10010 - Barium manganese oxide (BaMnO3).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Barium manganese oxide (BaMnO3). 721... Substances § 721.10010 Barium manganese oxide (BaMnO3). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as barium manganese oxide (BaMnO3) (PMN P-00...

  15. The diagnosis of gastro-esophageal reflux disease cannot be made with barium esophagograms

    NARCIS (Netherlands)

    Saleh, C. M. G.; Smout, A. J. P. M.; Bredenoord, A. J.

    2015-01-01

    For over 50 years, barium studies have been used to diagnose gastro-esophageal reflux disease (GERD), but the value of this test is controversial. Our study aimed to determine if barium esophagograms can be used to diagnose GERD. Barium esophagograms and pH-impedance measurement were performed in 20

  16. Barium Tagging from nEXO Using Resonance Ionization Spectroscopy

    Science.gov (United States)

    Twelker, K.; Kravitz, S.

    nEXO is a 5-ton liquid enriched-xenon time projection chamber (TPC) to search for neutrinoless double-beta decay, designed to have the sensitivity to completely probe the inverted mass hierarchy of Majorana neutrinos. The detector will accommodate-as a background reduction technique-a system to recover and identify the barium decay product. This upgrade will allow a background-free measurement of neutrinoless double-beta decay and increase the half-life sensitivity of the experiment by at least one order of magnitude. Ongoing research and development includes a system to test barium extraction from liquid xenon using surface adsorption and Resonance Ionization Spectroscopy (RIS).

  17. Electronic and chemical properties of barium and indium clusters

    International Nuclear Information System (INIS)

    Onwuagba, B.N.

    1992-11-01

    The ground state electronic and chemical properties of divalent barium and trivalent indium are investigated in a self-consistent manner using the spin-polarized local density approximation in the framework of Density Functional Theory. A jellium model is adopted in the spirit of Gunnarsson and Lundqvist exchange and correlation energies and the calculated properties primarily associated with the s-p orbitals in barium and p orbitals in indium provide deepened insight towards the understanding of the mechanisms to the magic numbers in both clusters. (author). 21 refs, 5 figs

  18. Comparison of endoscopy and barium swallow with marshmallow in dysphagia.

    Science.gov (United States)

    Somers, S; Stevenson, G W; Thompson, G

    1986-06-01

    Forty-four patients with dysphagia were examined both by endoscopy and by barium swallow with a marshmallow bolus. In these patients 36 stenoses were found: 34 by radiology and 30 by endoscopy. The radiologic criteria for stenosis included arrest of the marshmallow in a manner to support a column of barium and reproduction of the patient's symptoms at the time this occurred. Radiologic false negative findings were partly due to an inability by patients to swallow an adequate marshmallow bolus; endoscopic failures were associated with small endoscopes and mild stenoses.

  19. Esophageal intramural pseudodiverticulosis characterized by barium esophagography: a case report

    LENUS (Irish Health Repository)

    O'Connor, Owen J

    2010-05-21

    Abstract Introduction Esophageal intramural pseudodiverticulosis is a rare condition characterized by the dilatation of the submucosal glands. Case presentation We present a case of esophageal intramural pseudodiverticulosis in a 72-year-old Caucasian man who presented with dysphagia and with a background history of alcohol abuse. An upper gastrointestinal endoscopy of our patient showed an esophageal stricture with abnormal mucosal appearances, but no malignant cells were seen at biopsy. Appearances on a barium esophagram were pathognomonic for esophageal intramural pseudodiverticulosis. Conclusion We demonstrate the enduring usefulness of barium esophagography in the characterization of abnormal mucosal appearances at endoscopy.

  20. Barium atoms and N20 molecular agregates reaction

    International Nuclear Information System (INIS)

    Visticot, J.P.; Mestdagh, J.M.; Alcaraz, C.; Cuvellier, J.; Berlande, J.

    1988-06-01

    The collisions between a barium atom and N20 molecular agregates are studied, for a better understanding of the solvation part in a chemical reaction. The experiments are carried out in a crossed molecular beam device. The light coming from the collision zone is scattered, and analysed by means of a photon detector. A time-of-flight technique is applied in the investigation of the beam's polymer concentration. The results show a nearly negligible chemiluminescent effect in the reaction between barium and N20 polymer. A solvated BaO formation mechanism is proposed to justify the experimental results [fr

  1. Reaction between barium and nitrogen in liquid sodium

    International Nuclear Information System (INIS)

    Addison, C.C.; Pulham, R.J.; Trevillion, E.A.

    1975-01-01

    Nitrogen in increasing amounts has been added to separate solutions of barium in sodium of constant composition (ca.4.40 mol % Ba) at 300 0 C. After rendering each mixture homogenous using an electromagnetic pump, filtration, and nitrogen analysis, all the N 2 added has been found in solution up to a solution composition approximating to Ba 4 N (i.e. 1.1 mol % N) beyond which the quantity of dissolved N 2 decreases progressively due to precipitation of the nitride Ba 2 N. The solubilization is interpreted in terms of strong preferential solvation of the nitride ion by barium cations. (author)

  2. The Kerr nonlinearity of the beta-barium borate crystal

    DEFF Research Database (Denmark)

    Bache, Morten; Guo, Hairun; Zhou, Binbin

    2013-01-01

    A popular crystal for ultrafast cascading experiments is beta-barium-borate (β-BaB2O4, BBO). It has a decent quadratic nonlinear coefficient, and because the crystal is anisotropie it can be birefringence phase-matched for type I (oo → e) second-harmonic generation (SHG). For femtosecond experime......A popular crystal for ultrafast cascading experiments is beta-barium-borate (β-BaB2O4, BBO). It has a decent quadratic nonlinear coefficient, and because the crystal is anisotropie it can be birefringence phase-matched for type I (oo → e) second-harmonic generation (SHG). For femtosecond...

  3. Preparation and characterization of antimony barium composite oxide photocatalysts

    Science.gov (United States)

    Han, X. P.; Yao, B. H.; Pan, Q. H.; Pen, C.; Zhang, C. L.

    2018-01-01

    In this paper, two kinds of antimony barium composite oxide photocatalysts have been prepared by two methods and characterized by XRD and SEM. The photocatalytic activity was evaluated by a photocatalytic reactor and an ultraviolet spectrophotometer. The results showed that-BaSb2O5•4H2O, BaSb2O6 two kinds of antimony barium composite oxide photocatalysts were successfully prepared in this experiment and they showed good photocatalytic properties. In addition, BaSb2O6 morphology showed more regular, microstructure and better catalytic performance.

  4. Chloride Transport in Heterogeneous Formation

    Science.gov (United States)

    Mukherjee, A.; Holt, R. M.

    2017-12-01

    The chloride mass balance (CMB) is a commonly-used method for estimating groundwater recharge. Observations of the vertical distribution of pore-water chloride are related to the groundwater infiltration rates (i.e. recharge rates). In CMB method, the chloride distribution is attributed mainly to the assumption of one dimensional piston flow. In many places, however, the vertical distribution of chloride will be influenced by heterogeneity, leading to horizontal movement of infiltrating waters. The impact of heterogeneity will be particularly important when recharge is locally focused. When recharge is focused in an area, horizontal movement of chloride-bearing waters, coupled with upward movement driven by evapotranspiration, may lead to chloride bulges that could be misinterpreted if the CMB method is used to estimate recharge. We numerically simulate chloride transport and evaluate the validity of the CMB method in highly heterogeneous systems. This simulation is conducted for the unsaturated zone of Ogallala, Antlers, and Gatuna (OAG) formations in Andrews County, Texas. A two dimensional finite element model will show the movement of chloride through heterogeneous systems. We expect to see chloride bulges not only close to the surface but also at depths characterized by horizontal or upward movement. A comparative study of focused recharge estimates in this study with available recharge data will be presented.

  5. The first iron(III) complexes with cyclin-dependent kinase inhibitors: Magnetic, spectroscopic (IR, ES+ MS, NMR, Fe-57 Mossbauer), theoretical, and biological activity studies

    Czech Academy of Sciences Publication Activity Database

    Trávníček, Zdeněk; Popa, Igor; Čajan, Michal; Zbořil, R.; Kryštof, Vladimír; Mikulík, J.

    2010-01-01

    Roč. 104, č. 4 (2010), s. 405-417 ISSN 0162-0134 R&D Projects: GA MŠk 1M0512; GA ČR GA301/08/1649 Institutional research plan: CEZ:AV0Z50380511 Keywords : Iron(III) complexes * 57Fe Mössbauer spectroscopy * CDK inhibition Subject RIV: CA - Inorganic Chemistry Impact factor: 3.317, year: 2010

  6. Status of barium studies in the present era of oncology: Are they a history?

    Science.gov (United States)

    Mahajan, Abhishek; Desai, Subash; Sable, Nilesh Pandurang; Thakur, Meenakshi Haresh

    2016-01-01

    With the advent of the modern imaging technologies, the present era of oncology is seeing steady decline in requests for barium studies due to the many reasons. It is prudent to mention here, that, barium examinations cannot be made obsolete! Our aim to preserve the age old technique of barium studies not only to keep it going on but also for the betterment and appropriate management of the patient. Our goal is not to "save" barium studies simply to keep this technology alive, per se, but rather to preserve barium radiology for the quality in patient care.

  7. Valyl benzyl ester chloride

    Directory of Open Access Journals (Sweden)

    Grzegorz Dutkiewicz

    2010-02-01

    Full Text Available In the title compound (systematic name: 1-benzyloxy-3-methyl-1-oxobutan-2-aminium chloride, C12H18NO2+·Cl−, the ester group is approximately planar, with a maximum deviation of 0.040 (2 Å from the least-squares plane, and makes a dihedral angle of 28.92 (16° with the phenyl ring. The crystal structure is organized by N—H...Cl hydrogen bonds which join the two components into a chain along the b axis. Pairs of chains arranged antiparallel are interconnected by further N—H...Cl hydrogen bonds, forming eight-membered rings. Similar packing modes have been observed in a number of amino acid ester halides with a short unit-cell parameter of ca 5.5 Å along the direction in which the chains run.

  8. Chloride on the Move

    KAUST Repository

    Li, Bo

    2017-01-09

    Chloride (Cl−) is an essential plant nutrient but under saline conditions it can accumulate to toxic levels in leaves; limiting this accumulation improves the salt tolerance of some crops. The rate-limiting step for this process – the transfer of Cl− from root symplast to xylem apoplast, which can antagonize delivery of the macronutrient nitrate (NO3−) to shoots – is regulated by abscisic acid (ABA) and is multigenic. Until recently the molecular mechanisms underpinning this salt-tolerance trait were poorly defined. We discuss here how recent advances highlight the role of newly identified transport proteins, some that directly transfer Cl− into the xylem, and others that act on endomembranes in ‘gatekeeper’ cell types in the root stele to control root-to-shoot delivery of Cl−.

  9. SEPARATION OF BARIUM VALUES FROM URANYL NITRATE SOLUTIONS

    Science.gov (United States)

    Tompkins, E.R.

    1959-02-24

    The separation of radioactive barium values from a uranyl nitrate solution of neutron-irradiated uranium is described. The 10 to 20% uranyl nitrate solution is passed through a flrst column of a cation exchange resin under conditions favoring the adsorption of barium and certain other cations. The loaded resin is first washed with dilute sulfuric acid to remove a portion of the other cations, and then wash with a citric acid solution at pH of 5 to 7 to recover the barium along with a lesser amount of the other cations. The PH of the resulting eluate is adjusted to about 2.3 to 3.5 and diluted prior to passing through a smaller second column of exchange resin. The loaded resin is first washed with a citric acid solution at a pH of 3 to elute undesired cations and then with citric acid solution at a pH of 6 to eluts the barium, which is substantially free of undesired cations.

  10. Characterization of Barium Borate Frameworks Using Raman Spectroscopy.

    Science.gov (United States)

    Gharavi-Naeini, Jafar; Yoo, Kyung W; Stump, Nathan A

    2018-04-01

    Systematic micro-Raman scattering investigations have been carried out on Sm +2 doped 2(BaO)-n(B 2 O 3 ) matrices for n = 4, 5, 8, and 2(BaO)-(Na 2 O)-9(B 2 O 3 ) using the 364 nm excitation of an Ar + laser. The Raman results have been compared with the known structures of barium tetraborate, barium pentaborate, barium octaborate, and barium sodium nonaborate. An excellent correlation has been found between the BO 4 /BO 3 composition ratios for each product and intensity ratios of the designated BO 4 and BO 3 Raman peaks. Furthermore, the Raman frequencies of both BO 4 and BO 3 groups undergo a systematic blueshift as n increases from four to nine. The shift results from a decrease of the B-O bond lengths for both BO 4 and BO 3 groups as the samples transition from the tetraborate to nonaborate structures. Linear relations (with negative slopes) have been determined between the measured Raman frequencies and B-O bond lengths in the frameworks.

  11. Dynamics of a barium release in the magnetospheric tail

    Science.gov (United States)

    Mende, S. B.; Swenson, G. R.; Geller, S. P.; Doolittle, J. H.; Haerendel, G.

    1989-01-01

    The late time behavior of the May 13, 1985 magnetotail barium cloud is examined. The bulk dynamics of the cloud are studied based on triangulated data and data from Fabry-Perot Doppler velocity measurements. The changes in cloud morphology in relation to the in situ measurements made by the Ion Release Module satellite are discussed.

  12. Barium titanate inverted opals-synthesis, characterization, and optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Soten, I.; Miguez, H.; Yang, S.M.; Petrov, S.; Coombs, N.; Tetreault, N.; Ozin, G.A. [Toronto Univ., ON (Canada). Dept. of Chemistry; Matsuura, N.; Ruda, H.E. [Toronto Univ., ON (Canada). Dept. of Metallurgy and Materials Science

    2002-01-01

    The engineering of cubic or tetragonal polymorphs of nanocrystalline barium titanate inverted opals has been achieved by thermally induced transformations. Optical characterization demonstrated photonic crystal behavior of the opals. The tuning of the ferroelectric-paraelectric transition around the Curie temperature is shown in this paper. (orig.)

  13. Electrical transport properties of calcium and barium aluminates

    NARCIS (Netherlands)

    Metselaar, R.; Hoefsloot, A.M.

    1987-01-01

    Electrical conductivity and ionic transport numbers have been measured of barium and calcium aluminates with composition CaO·nAl2O3 (n=7/12, 1, 2, 6) and 0.82 BaO·6Al2O3. At room temperatures these compounds are insulators, but at high temperatures mixed conductivity is observed. Ionic transport

  14. ORIGINAL ARTICLE ORIG ORIG Comparison of barium and ...

    African Journals Online (AJOL)

    SA JOURNAL OF RADIOLOGY • June 2007. ORIG. Abstract. Background. Simulation of patients with carcinoma of the oesophagus using radio-opaque contrast is a standard step in treatment planning prior to delivering radiation therapy. Various contrast mediums such as barium, gastrograffin and hexabrix have been used ...

  15. Synthesis and surface properties of submicron barium sulfate particles

    International Nuclear Information System (INIS)

    Zhang Ming; Zhang Bao; Li Xinhai; Yin Zhoulan; Guo Xueyi

    2011-01-01

    Barium sulfate particles were synthesized in the presence of EDTA at room temperature. X-ray diffractometry (XRD), Fourier transform infrared resonance (FTIR) and scanning electron microscopy (SEM) were used to characterize the structure and morphology of BaSO 4 particles. The effect of the preparation parameters on the particle size distribution and morphology was investigated. The conditional formation constants of Ba-EDTA at different pH values were calculated. The results show that the size and morphology of BaSO 4 particles can be effectively controlled by adding EDTA in the precipitation process. Among all the operation conditions, the pH value has significant effect on the particle size. The obtained barium sulfate particles are spherical and well dispersed at pH = 9-10. Zeta potentials of BaSO 4 were measured at different pH. The isoelectric point (IEP) of barium sulfate colloid appears at pH 6.92. The model of the solid-solution interface at a particle of BaSO 4 was presented. The FTIR result indicates that the surface of the prepared BaSO 4 absorbs the functional groups of EDTA, which lower the IEP of the barium sulfate particles.

  16. Synthesis and surface properties of submicron barium sulfate particles

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Ming, E-mail: csu.light@yahoo.com.cn [College of Chemistry and Chemical Engineering, Zhaoqing University, Zhaoqing 526061 (China); School of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); Zhang Bao; Li Xinhai [School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China); Yin Zhoulan [School of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); Guo Xueyi [School of Metallurgical Science and Engineering, Central South University, Changsha 410083 (China)

    2011-10-15

    Barium sulfate particles were synthesized in the presence of EDTA at room temperature. X-ray diffractometry (XRD), Fourier transform infrared resonance (FTIR) and scanning electron microscopy (SEM) were used to characterize the structure and morphology of BaSO{sub 4} particles. The effect of the preparation parameters on the particle size distribution and morphology was investigated. The conditional formation constants of Ba-EDTA at different pH values were calculated. The results show that the size and morphology of BaSO{sub 4} particles can be effectively controlled by adding EDTA in the precipitation process. Among all the operation conditions, the pH value has significant effect on the particle size. The obtained barium sulfate particles are spherical and well dispersed at pH = 9-10. Zeta potentials of BaSO{sub 4} were measured at different pH. The isoelectric point (IEP) of barium sulfate colloid appears at pH 6.92. The model of the solid-solution interface at a particle of BaSO{sub 4} was presented. The FTIR result indicates that the surface of the prepared BaSO{sub 4} absorbs the functional groups of EDTA, which lower the IEP of the barium sulfate particles.

  17. Pressure-assisted sintering of high purity barium titanate

    NARCIS (Netherlands)

    van den Cruijsem, S.; Varst, van der P.G.T.; With, de G.; Bortzmeyer, D.; Boussuge, M.; Chartier, Th.; Hausonne, J.M.; Mocellin, A.; Rousset, A.; Thevenot, F.

    1997-01-01

    The dielectric behaviour of High Purity Barium titanate (HPB) ceramics is strongly dependent on the grain size and porosity. For applications, control of grain size and porosity is required. Pressure-assisted sintering techniques at relatively low temperatures meet these requirements. In this study,

  18. Iatrogen perforation of the rectum following barium enema

    International Nuclear Information System (INIS)

    Eggum, R.; Kressner, U.; Haffner, J.

    1998-01-01

    Perforation of the rectum following barium enema is relatively rare, occurring in 1 of 3,000 procedures. Colorectal perforation is a serious condition and early diagnosis is of paramount importance in order to avoid any delay in treating the patient. Direct suture of the perforation, lavage, presacral drainage and stomia are the preferred methods of primary surgical treatment. 10 refs., 1 fig

  19. Effectiveness of therapeutic barium enema for diverticular hemorrhage

    Science.gov (United States)

    Matsuura, Mizue; Inamori, Masahiko; Nakajima, Atsushi; Komiya, Yasuhiko; Inoh, Yumi; Kawasima, Keigo; Naitoh, Mai; Fujita, Yuji; Eduka, Akiko; Kanazawa, Noriyoshi; Uchiyama, Shiori; Tani, Rie; Kawana, Kennichi; Ohtani, Setsuya; Nagase, Hajime

    2015-01-01

    AIM: To evaluate the effectiveness of barium impaction therapy for patients with colonic diverticular bleeding. METHODS: We reviewed the clinical charts of patients in whom therapeutic barium enema was performed for the control of diverticular bleeding between August 2010 and March 2012 at Yokohama Rosai Hospital. Twenty patients were included in the review, consisting of 14 men and 6 women. The median age of the patients was 73.5 years. The duration of the follow-up period ranged from 1 to 19 mo (median: 9.8 mo). Among the 20 patients were 11 patients who required the procedure for re-bleeding during hospitalization, 6 patients who required it for re-bleeding that developed after the patient left the hospital, and 3 patients who required the procedure for the prevention of re-bleeding. Barium (concentration: 150 w%/v%) was administered per the rectum, and the leading edge of the contrast medium was followed up to the cecum by fluoroscopy. After confirmation that the ascending colon and cecum were filled with barium, the enema tube was withdrawn, and the patient’s position was changed every 20 min for 3 h. RESULTS: Twelve patients remained free of re-bleeding during the follow-up period (range: 1-19 mo) after the therapeutic barium enema, including 9 men and 3 women with a median age of 72.0 years. Re-bleeding occurred in 8 patients including 5 men and 3 women with a median age of 68.5 years: 4 developed early re-bleeding, defined as re-bleeding that occurs within one week after the procedure, and the remaining 4 developed late re-bleeding. The DFI (disease-free interval) decreased 0.4 for 12 mo. Only one patient developed a complication from therapeutic barium enema (colonic perforation). CONCLUSION: Therapeutic barium enema is effective for the control of diverticular hemorrhage in cases where the active bleeding site cannot be identified by colonoscopy. PMID:25987779

  20. Arsenic removal with iron(II) and iron(III) in waters with high silicate and phosphate concentrations.

    Science.gov (United States)

    Roberts, Linda C; Hug, Stephan J; Ruettimann, Thomas; Billah, Morsaline; Khan, Abdul Wahab; Rahman, Mohammad Tariqur

    2004-01-01

    Arsenic removal by passive treatment, in which naturally present Fe(II) is oxidized by aeration and the forming iron(III) (hydr)oxides precipitate with adsorbed arsenic, is the simplest conceivable water treatment option. However, competing anions and low iron concentrations often require additional iron. Application of Fe(II) instead of the usually applied Fe(III) is shown to be advantageous, as oxidation of Fe(II) by dissolved oxygen causes partial oxidation of As(III) and iron(III) (hydr)oxides formed from Fe(II) have higher sorption capacities. In simulated groundwater (8.2 mM HCO3(-), 2.5 mM Ca2+, 1.6 mM Mg2+, 30 mg/L Si, 3 mg/L P, 500 ppb As(III), or As(V), pH 7.0 +/- 0.1), addition of Fe(II) clearly leads to better As removal than Fe(III). Multiple additions of Fe(II) further improved the removal of As(II). A competitive coprecipitation model that considers As(III) oxidation explains the observed results and allows the estimation of arsenic removal under different conditions. Lowering 500 microg/L As(III) to below 50 microg/L As(tot) in filtered water required > 80 mg/L Fe(III), 50-55 mg/L Fe(II) in one single addition, and 20-25 mg/L in multiple additions. With As(V), 10-12 mg/L Fe(II) and 15-18 mg/L Fe(III) was required. In the absence of Si and P, removal efficiencies for Fe(II) and Fe(III) were similar: 30-40 mg/L was required for As(II), and 2.0-2.5 mg/L was required for As(V). In a field study with 22 tubewells in Bangladesh, passive treatment efficiently removed phosphate, but iron contents were generally too low for efficient arsenic removal.

  1. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1989-08-15

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction.

  2. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    International Nuclear Information System (INIS)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup

    1989-01-01

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction

  3. The Barium Site in a Potassium Channel by X-Ray Crystallography

    Science.gov (United States)

    Jiang, Youxing; MacKinnon, Roderick

    2000-01-01

    X-ray diffraction data were collected from frozen crystals (100°K) of the KcsA K+ channel equilibrated with solutions containing barium chloride. Difference electron density maps (Fbarium − Fnative, 5.0 Å resolution) show that Ba2+ resides at a single location within the selectivity filter. The Ba2+ blocking site corresponds to the internal aspect (adjacent to the central cavity) of the “inner ion” position where an alkali metal cation is found in the absence of the blocking Ba2+ ion. The location of Ba2+ with respect to Rb+ ions in the pore is in good agreement with the findings on the functional interaction of Ba2+ with K+ (and Rb+) in Ca2+-activated K+ channels (Neyton, J., and C. Miller. 1988. J. Gen. Physiol. 92:549–567). Taken together, these structural and functional data imply that at physiological ion concentrations a third ion may interact with two ions in the selectivity filter, perhaps by entering from one side and displacing an ion on the opposite side. PMID:10694255

  4. Novel thermally stable poly(vinyl chloride) composites for sulfate removal

    Energy Technology Data Exchange (ETDEWEB)

    Nadagouda, Mallikarjuna N., E-mail: Nadagouda.mallikarjuna@epa.gov [Water Supply and Water Resources Division, National Risk Management Research Laboratory U.S. Environmental Protection Agency, 26 W. Martin Luther King Drive Cincinnati, Ohio 45268 (United States); Pressman, Jonathan; White, Colin; Speth, Thomas F.; McCurry, Daniel L. [Water Supply and Water Resources Division, National Risk Management Research Laboratory U.S. Environmental Protection Agency, 26 W. Martin Luther King Drive Cincinnati, Ohio 45268 (United States)

    2011-04-15

    Graphical abstract: Barium carbonate and/or barium carbonate-loaded silica aero-gels dispersed polyvinyl chloride (PVC) composites were prepared by dissolving PVC in tetrahydrofuran (THF), dispersing BaCO{sub 3} and/or BaCO{sub 3}-loaded silica aero-gels, re-precipitating the PVC with water at room temperature. The PVC composites were then characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray mapping, X-ray diffraction (XRD), thermogravimetric analysis (TGA) and inductively coupled plasma mass spectrometry (ICP-MS) analysis. The obtained composites had better thermal properties than the control PVC. The composites were tested for sulfate removal and found to significantly reduce sulfate when compared with control PVC. - Abstract: BaCO{sub 3} dispersed PVC composites were prepared through a polymer re-precipitation method. The composites were tested for sulfate removal using rapid small scale column test (RSSCT) and found to significantly reduce sulfate concentration. The method was extended to synthesize barium carbonate-loaded silica aero-gels-polyvinyl chloride (PVC) polymer composites. The PVC composites were characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray mapping, X-ray diffraction (XRD), thermogravimetric analysis (TGA) and inductively coupled plasma mass spectrometry (ICP-MS) analysis. The method has advantages over conventional sulfate precipitation (sulfate removal process) using BaCO{sub 3} wherein clogging of the filter can be avoided. The method is environmentally friendly and does not interfere with natural organic matter as the conventional resin does. Some of the composites were thermally more stable as compared with the pure PVC discussed in the literature.

  5. Novel thermally stable poly(vinyl chloride) composites for sulfate removal

    International Nuclear Information System (INIS)

    Nadagouda, Mallikarjuna N.; Pressman, Jonathan; White, Colin; Speth, Thomas F.; McCurry, Daniel L.

    2011-01-01

    Graphical abstract: Barium carbonate and/or barium carbonate-loaded silica aero-gels dispersed polyvinyl chloride (PVC) composites were prepared by dissolving PVC in tetrahydrofuran (THF), dispersing BaCO 3 and/or BaCO 3 -loaded silica aero-gels, re-precipitating the PVC with water at room temperature. The PVC composites were then characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray mapping, X-ray diffraction (XRD), thermogravimetric analysis (TGA) and inductively coupled plasma mass spectrometry (ICP-MS) analysis. The obtained composites had better thermal properties than the control PVC. The composites were tested for sulfate removal and found to significantly reduce sulfate when compared with control PVC. - Abstract: BaCO 3 dispersed PVC composites were prepared through a polymer re-precipitation method. The composites were tested for sulfate removal using rapid small scale column test (RSSCT) and found to significantly reduce sulfate concentration. The method was extended to synthesize barium carbonate-loaded silica aero-gels-polyvinyl chloride (PVC) polymer composites. The PVC composites were characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray mapping, X-ray diffraction (XRD), thermogravimetric analysis (TGA) and inductively coupled plasma mass spectrometry (ICP-MS) analysis. The method has advantages over conventional sulfate precipitation (sulfate removal process) using BaCO 3 wherein clogging of the filter can be avoided. The method is environmentally friendly and does not interfere with natural organic matter as the conventional resin does. Some of the composites were thermally more stable as compared with the pure PVC discussed in the literature.

  6. Cerium(terbium, erbium)chloride-choline chloride aqueous systems

    International Nuclear Information System (INIS)

    Gajfutdinova, R.K.; Zhuravlev, E.F.; Bikbaeva, G.G.; Domrachev, V.N.; Vanskova, G.I.

    1985-01-01

    To clarify the effect of rare earth nature on mutual solubility of rare earth salts and amines the solubility of solid phases in the systems, consisting of choline chloride, water and cerium, terbium, erbium chlorides, has been studied. It is established, that solubility isotherms of all the systems, testify to the formation of new solid phases of the composition: Ce(Tb, Er)xCl 3 x2C 5 H 14 ONClx3H 2 O. Individuality of new solid phases is proved by DTA method, the composition is confirmed by chemical analysis and data of PMR spectra, for choline chloride and its complexes with rare earth chlorides of the given composition PMR and IR spectra are studied

  7. Iron(III) diethylenetriaminepentaacetic acid complex on polyallylamine functionalized multiwalled carbon nanotubes: immobilization, direct electrochemistry and electrocatalysis.

    Science.gov (United States)

    Liu, Hailing; Cui, Yanyun; Li, Pan; Zhou, Yiming; Zhu, Xiaoshu; Tang, Yawen; Chen, Yu; Lu, Tianhong

    2013-05-07

    A nonenzymatic iron(III) diethylenetriaminepentaacetic acid (Fe(III)-DETPA) complex based amperometric sensor for the analytical determination of hydrogen peroxide was developed. By combining the electrostatic interaction between the Fe(III)-DETPA complex and polyallylamine (PAH) functionalized multiwalled carbon nanotubes (MWCNTs) as well as the ionotropic crosslinking interaction between PAH and ethylenediamine-tetramethylene phosphonic acid (EDTMP), the electroactive Fe(III)-DETPA complex was successfully incorporated within the MWCNT matrix, and firmly immobilized on the Au substrate electrode. The fabricated electrochemical sensor was characterized with scanning electron microscopy (SEM), transmission electron microscopy (TEM) and electrochemical methods. The influences of solution pH and ionic strength on the electrochemical sensor were investigated. The prepared electrochemical sensor had a fast response to hydrogen peroxide (<3 s) and an excellent linear range of concentration from 1.25 × 10(-8) to 4.75 × 10(-3) M with a detection limit of 6.3 × 10(-9) M under the optimum conditions.

  8. Kinetics and mechanism of reduction of iron(iii) kojic acid complex by hydroquinone and l-cysteine

    International Nuclear Information System (INIS)

    Hussain, Z.; Perviaz, M.; Kazmi, S.A.; Johnson, A.S.; Offiong, O.E.

    2014-01-01

    The effect of pH on the kinetics of reduction of iron(III) kojic acid complex by hydroquinone (H/sub 2/Q) and L-cysteine (L-Cys) was studied in the pH range of 2.34 - 4.03 for H/sub 2/Q and 3.04 - 5.5 for L-cysteine at ionic strength of 0.5 M and at 35 degree C. The pseudo-first order rate constants for the reduction of Fe(KA)3 by L-cysteine and hydroquinone increase linearly with increasing reductant concentration, indicating first-order kinetics in reductant concentration. However, whereas the rate of reduction by H2Q increases with increasing pH, an opposite trend was observed in the case of reduction by L-cysteine. Plausible rate laws and mechanisms have been proposed in line with these observations. Activation parameters (delta H no and delta S no) were evaluated for the reduction of iron (III) kojic acid complex by cysteine and the values obtained are 35.25 kJmol-1, -141.4 JK-1mol-1 and 28.14 kJmol-1 , 161.2 JK-1mol-1 for pH 4.5 and 3.52 respectively. (author)

  9. Iron(III) protoporphyrin IX-single-wall carbon nanotubes modified electrodes for hydrogen peroxide and nitrite detection

    International Nuclear Information System (INIS)

    Turdean, Graziella L.; Popescu, Ionel Catalin; Curulli, Antonella; Palleschi, Giuseppe

    2006-01-01

    Iron(III) protoporphyrin IX (Fe(III)P), adsorbed either on single-walled carbon nanotubes (SWCNT) or on hydroxyl-functionalized SWCNT (SWCNT-OH), was incorporated within a Nafion matrix immobilized on the surface of a graphite electrode. From cyclic voltammetric measurements, performed under different experimental conditions (pH and potential scan rate), it was established that the Fe(III)P/Fe(II)P redox couple involves 1e - /1H + . The heterogeneous electron transfer process occurred faster when Fe(III)P was adsorbed on SWCNT-OH (∼11 s -1 ) than on SWCNT (∼4.9 s -1 ). Both the SWCNT-Fe(III)P- and SWCNT-OH-Fe(III)P-modified graphite electrodes exhibit electrocatalytic activity for H 2 O 2 and nitrite reduction. The modified electrodes sensitivities were found varying in the following sequences: S SWCNT-OH-Fe(III)P = 2.45 mA/M ∼ S SWCNT-Fe(III)P = 2.95 mA/M > S Fe(III)P = 1.34 mA/M for H 2 O 2 , and S SWCNT-Fe(III)P = 3.54 mA/M > S Fe(III)P 1.44 mA/M > S SWCNT-OH-Fe(III)P = 0.81 mA/M for NO 2 -

  10. Effects of chemesthetic stimuli mixtures with barium on swallowing apnea duration.

    Science.gov (United States)

    Todd, J Tee; Butler, Susan G; Plonk, Drew P; Grace-Martin, Karen; Pelletier, Cathy A

    2012-10-01

    This study tested the hypotheses that swallowing apnea duration (SAD) will increase given barium versus water, chemesthetic stimuli (i.e., water barium, age (older > younger), and genetic taste differences (supertasters > nontasters). Prospective group design. University Medical Center. Eighty healthy women were identified as nontasters and supertasters, equally comprising two age groups: 18 to 35 years and 60+ years. The KayPentax Swallowing Signals Lab was used to acquire SAD via nasal cannula during individually randomized swallows of 5 mL barium, 2.7% w/v citric acid with barium, carbonation with barium, and 50:50 diluted ethanol with barium. Data were analyzed using path analysis, with the mediator of chemesthetic perception, adjusted for repeated measures. Significant main effects of age (P = .012) and chemesthetic stimuli (P = .014) were found, as well as a significant interaction between chemesthetic stimuli and age (P = .028). Older women had a significantly longer SAD than younger women. Post hoc analyses revealed that barium mixed with ethanol elicited a significantly longer SAD than other bolus conditions, regardless of age group. There were no significant differences in SAD between barium and water conditions, and no significant effect of chemesthetic perception (P > .05). Ethanol added to barium elicited longer SAD compared to plain barium, but not the other chemesthetic conditions. Older women had a longer SAD than younger women in all conditions. These findings may influence design of future studies examining effects of various stimuli on SAD. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  11. Gas thermodesorption study of barium and strontium cerates

    International Nuclear Information System (INIS)

    Aksenova, T.I.; Khromushin, I.V.; Zhotabaev, Zh.R.; Bukenov, K.D.; Medvedeva, Z.V.; Berdauletov, A.K.

    2002-01-01

    Kinetic of water, oxygen, hydrogen and carbon dioxide molecules release from doped and undoped samples of barium cerates and doped strontium cerates during vacuum heating was studied. The samples were prepared by inductive melting method. The following two kinds of preliminary samples treatments were used: annealing in air (650-750 deg. C) and wet nitrogen atmosphere (625 deg.C). Main results of thermodesorption studies of barium and strontium cerates are represented in the table. The samples of doped LaSrMnO were investigated also. It was found that the initial doped samples (without preliminary annealing) did not show any gas release in temperature range of 20-1100 deg. C. This fact indicates on high stability of compositions and strong bond of 'host' oxygen in their lattice. A significant amount of water and oxygen molecules were released from BaCe 0.9 Nd 0.1 O 3 samples whereas water and hydrogen molecules desorption from SrCe 0.95 Y 0.05 O 3 samples took place. Hydrogen molecules desorption was found for strontium cerates samples; no hydrogen molecules release was observed for doped and pure barium cerate samples.Intensive water molecules release from doped samples confirms the necessity of oxygen vacancies creation in these compounds to get properties of proton conductivity, since it was not found any water molecules release from annealed undoped samples of BaCeO 3 It is necessary to notice that oxygen molecules release from these samples took place at ∼1000 deg. C that is significantly higher then from BaCeNdO samples. Forms of high temperatures part of oxygen and low temperature part of water spectra indicate that phase transformations are responsible for oxygen and water molecules desorption in this cases. These results are in good agreement with literature data. Desorption of water molecules from barium and strontium cerates took place. Oxygen desorption took place only from barium cerates. It can be explained as the following: doped barium cerates have

  12. Exposure to low-dose barium by drinking water causes hearing loss in mice.

    Science.gov (United States)

    Ohgami, Nobutaka; Hori, Sohjiro; Ohgami, Kyoko; Tamura, Haruka; Tsuzuki, Toyonori; Ohnuma, Shoko; Kato, Masashi

    2012-10-01

    We continuously ingest barium as a general element by drinking water and foods in our daily life. Exposure to high-dose barium (>100mg/kg/day) has been shown to cause physiological impairments. Direct administration of barium to inner ears by vascular perfusion has been shown to cause physiological impairments in inner ears. However, the toxic influence of oral exposure to low-dose barium on hearing levels has not been clarified in vivo. We analyzed the toxic influence of oral exposure to low-dose barium on hearing levels and inner ears in mice. We orally administered barium at low doses of 0.14 and 1.4 mg/kg/day to wild-type ICR mice by drinking water. The doses are equivalent to and 10-fold higher than the limit level (0.7 mg/l) of WHO health-based guidelines for drinking water, respectively. After 2-week exposure, hearing levels were measured by auditory brain stem responses and inner ears were morphologically analyzed. After 2-month exposure, tissue distribution of barium was measured by inductively coupled plasma mass spectrometry. Low-dose barium in drinking water caused severe hearing loss in mice. Inner ears including inner and outer hair cells, stria vascularis and spiral ganglion neurons showed severe degeneration. The Barium-administered group showed significantly higher levels of barium in inner ears than those in the control group, while barium levels in bone did not show a significant difference between the two groups. Barium levels in other tissues including the cerebrum, cerebellum, heart, liver and kidney were undetectably low in both groups. Our results demonstrate for the first time that low-dose barium administered by drinking water specifically distributes to inner ears resulting in severe ototoxicity with degeneration of inner ears in mice. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Regeneration of barium carbonate from barium sulphide in a pilot-scale bubbling column reactor and utilization for acid mine drainage

    CSIR Research Space (South Africa)

    Mulopo, J

    2012-01-01

    Full Text Available Batch regeneration of barium carbonate (BaCO3) from barium sulphide (BaS) slurries by passing CO2 gas into a pilot-scale bubbling column reactor under ambient conditions was used to assess the technical feasibility of BaCO3 recovery in the Alkali...

  14. Chloride removal from plutonium alloy

    International Nuclear Information System (INIS)

    Holcomb, H.P.

    1983-01-01

    SRP is evaluating a program to recover plutonium from a metallic alloy that will contain chloride salt impurities. Removal of chloride to sufficiently low levels to prevent damaging corrosion to canyon equipment is feasible as a head-end step following dissolution. Silver nitrate and mercurous nitrate were each successfully used in laboratory tests to remove chloride from simulated alloy dissolver solution containing plutonium. Levels less than 10 ppM chloride were achieved in the supernates over the precipitated and centrifuged insoluble salts. Also, less than 0.05% loss of plutonium in the +3, +4, or +6 oxidation states was incurred via precipitate carrying. These results provide impetus for further study and development of a plant-scale process to recover plutonium from metal alloy at SRP

  15. Surface studies of barium and barium oxide on tungsten and its application to understanding the mechanism of operation of an impregnated tungsten cathode

    Science.gov (United States)

    Forman, R.

    1976-01-01

    Surface studies have been made of multilayer and monolayer films of barium and barium oxide on a tungsten substrate. The purpose of the investigation was to synthesize the surface conditions that exist on an activated impregnated tungsten cathode and obtain a better understanding of the mechanism of operation of such cathodes. The techniques employed in these measurements were Auger spectroscopy and work-function measurements. The results of this study show that the surface of an impregnated cathode is identical to that observed for a synthesized monolayer or partial monolayer of barium on oxidized tungsten by evaluating Auger spectra and work-function measurements. Data obtained from desorption studies of barium monolayers on a tungsten substrate in conjunction with Auger and work-function results have been interpreted to show that throughout most of its life an impreganated cathode has a partial monolayer, rather than a monolayer, of barium on its surface.

  16. NASA/Max Planck Institute Barium Ion Cloud Project.

    Science.gov (United States)

    Brence, W. A.; Carr, R. E.; Gerlach, J. C.; Neuss, H.

    1973-01-01

    NASA and the Max Planck Institute for Extraterrestrial Physics (MPE), Munich, Germany, conducted a cooperative experiment involving the release and study of a barium cloud at 31,500 km altitude near the equatorial plane. The release was made near local magnetic midnight on Sept. 21, 1971. The MPE-built spacecraft contained a canister of 16 kg of Ba CuO mixture, a two-axis magnetometer, and other payload instrumentation. The objectives of the experiment were to investigate the interaction of the ionized barium cloud with the ambient medium and to deduce the properties of electric fields in the proximity of the release. An overview of the project is given to briefly summarize the organization, responsibilities, objectives, instrumentation, and operational aspects of the project.

  17. Attainment of barium hexaferrite nanoparticles by a Pechini Method

    International Nuclear Information System (INIS)

    Galvao, S.B.; Timoteo, Jr.J.F.; Melo, G.M.; Souto, K.K.O.; Florioto, N.T.; Paskocimas, C.A.

    2009-01-01

    The barium hexaferrites (BaFe 12 O 19 ) are used as a compound of materials applied in electronic devices, as medical devices, satellites, dada servers systems, wireless systems and others. The general properties are strongly related to the microstructure and morphology, and the particles size decrease results in advantages to the majority applications, mainly the high-tech thumbnail devices. These magnetic ceramic materials, with perovskite structure, are traditionally prepared my conventional oxide mixture synthesis. In this work was studied the nanoparticle synthesis of BaFe 12 O 19 by the precursors polymeric method (Pechini), using as precursors the barium carbonate and the iron nitrate, under different thermal treatment conditions. The samples were characterized by XRD, SEM, BET, DTA and TGA. The results presented the attainment of a monophasic powder with particles size around 100 nm. (author)

  18. Influence of Magnetron Effect on Barium Hexaferrite Thin Layers

    International Nuclear Information System (INIS)

    Hassane, H.; Chatelon, J.P.; Rousseau, J.J; Siblini, A.; Kriga, A.

    2011-01-01

    In this paper, we study the effects of a magnet, located in the cathode, on barium hexaferrite thin films deposited by RF magnetron sputtering technique. During the process, these effects can modify thickness, roughness and stress of coatings. The characteristics of the deposited layers depend on the substrate position that is located opposite of magnetron cathode. In the m agnetron area , one can observe that the high stress can produce cracks or detachment of layers and the increasing of both depositing rate and surface roughness. After sputtering elaboration, barium hexaferrite films are in a compressive stress mode. But, after the post-deposition heat treatment these films are in a tensile stress mode. To improve the quality of BaM films, the subsrtate has to be set outside the magnetron area. (author)

  19. Electromagnetic properties of carbon black and barium titanate composite materials

    International Nuclear Information System (INIS)

    Wang Guiqin; Chen Xiaodong; Duan Yuping; Liu Shunhua

    2008-01-01

    Nanocrystalline carbon black/barium titanate compound particle (CP) was synthesized by sol-gel method. The phase structure and morphology of compound particle were investigated by X-ray diffraction (XRD), transmission electron microscope (TEM) and Raman spectrum measurements, the electroconductivity was test by trielectrode arrangement and the precursor powder was followed by differential scanning calorimetric measurements (DSC) and thermal gravimetric analysis (TGA). In addition, the complex relative permittivity and permeability of compound particle were investigated by reflection method. The compound particle/epoxide resin composite (CP/EP) with different contents of CP were measured. The results show barium titanate crystal is tetragonal phase and its grain is oval shape with 80-100 nm which was coated by carbon black film. As electromagnetic (EM) complex permittivity, permeability and reflection loss (RL) shown that the compound particle is mainly a kind of electric and dielectric lossy materials and exhibits excellent microwave absorption performance in the X- and Ku-bands

  20. Attainment of barium hexa ferrite nanoparticles by a Pechini method

    International Nuclear Information System (INIS)

    Galvao, Sheila B.; Timoteo, Flavio Junior J.; Machado, Tercio G.; Souto, Kesia K.O.; Floreoto, Neide T.; Paskocimas, Carlos A.

    2009-01-01

    The barium hexa ferrites (BaFe 12 O 19 ) are used as a compound of materials applied in electronic devices, as medical devices, satellites, dada servers systems, wireless systems and others. The general properties are strongly related to the microstructure and morphology, and the particles size decrease results in advantages to the majority applications, mainly the high-tech thumbnail devices. These magnetic ceramic materials, with perovskite structure, are traditionally prepared my conventional oxide mixture synthesis. In this work was studied the nanoparticle synthesis of BaFe 12 O 19 by the precursors polymeric method (Pechini), using as precursors the barium carbonate and the iron nitrate, under different thermal treatment conditions. The samples were characterized by XRD, Raman spectroscopy, SEM, BET, DTA and TGA. The results presented the attainment of a monophasic powder with particles size around 100 nm. (author)

  1. Electromagnetic properties of photodefinable barium ferrite polymer composites

    Science.gov (United States)

    Sholiyi, Olusegun; Lee, Jaejin; Williams, John D.

    2014-07-01

    This article reports the magnetic and microwave properties of a Barium ferrite powder suspended in a polymer matrix. The sizes for Barium hexaferrite powder are 3-6 μm for coarse and 0.8-1.0 μm for the fine powder. Ratios 1:1 and 3:1 (by mass) of ferrite to SU8 samples were characterized and analyzed for predicting the necessary combinations of these powders with SU8 2000 Negative photoresist. The magnetization properties of these materials were equally determined and were analyzed using Vibrating Sample Magnetometer (VSM). The Thru, Reflect, Line (TRL) calibration technique was employed in determining complex relative permittivity and permeability of the powders and composites with SU8 between 26.5 and 40 GHz.

  2. Electromagnetic properties of photodefinable barium ferrite polymer composites

    Directory of Open Access Journals (Sweden)

    Olusegun Sholiyi

    2014-07-01

    Full Text Available This article reports the magnetic and microwave properties of a Barium ferrite powder suspended in a polymer matrix. The sizes for Barium hexaferrite powder are 3–6 μm for coarse and 0.8–1.0 μm for the fine powder. Ratios 1:1 and 3:1 (by mass of ferrite to SU8 samples were characterized and analyzed for predicting the necessary combinations of these powders with SU8 2000 Negative photoresist. The magnetization properties of these materials were equally determined and were analyzed using Vibrating Sample Magnetometer (VSM. The Thru, Reflect, Line (TRL calibration technique was employed in determining complex relative permittivity and permeability of the powders and composites with SU8 between 26.5 and 40 GHz.

  3. Dynamic electrochemical measurement of chloride ions

    NARCIS (Netherlands)

    Abbas, Yawar; de Graaf, Derk B.; Olthuis, Wouter; van den Berg, Albert

    2016-01-01

    This protocol describes the dynamic measurement of chloride ions using the transition time of a silver silver chloride (Ag/AgCl) electrode. Silver silver chloride electrode is used extensively for potentiometric measurement of chloride ions concentration in electrolyte. In this measurement,

  4. Producing ammonium chloride from coal or shale

    Energy Technology Data Exchange (ETDEWEB)

    Christenson, O L

    1921-02-25

    Process of producing ammonium chloride consists of mixing the substance to be treated with a chloride of an alkali or alkaline earth metal, free silica, water and free hydrochloric acid, heating the mixture until ammonium chloride distills off and collecting the ammonium chloride.

  5. 21 CFR 184.1138 - Ammonium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ammonium chloride. 184.1138 Section 184.1138 Food... Specific Substances Affirmed as GRAS § 184.1138 Ammonium chloride. (a) Ammonium chloride (NH4Cl, CAS Reg. No. 12125-02-9) is produced by the reaction of sodium chloride and an ammonium salt in solution. The...

  6. 21 CFR 173.375 - Cetylpyridinium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Cetylpyridinium chloride. 173.375 Section 173.375... CONSUMPTION Specific Usage Additives § 173.375 Cetylpyridinium chloride. Cetylpyridinium chloride (CAS Reg. No....1666 of this chapter, at a concentration of 1.5 times that of cetylpyridinium chloride. (c) The...

  7. 21 CFR 184.1622 - Potassium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Potassium chloride. 184.1622 Section 184.1622 Food... Specific Substances Affirmed as GRAS § 184.1622 Potassium chloride. (a) Potassium chloride (KCl, CAS Reg... levels not to exceed current good manufacturing practice. Potassium chloride may be used in infant...

  8. 21 CFR 184.1426 - Magnesium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Magnesium chloride. 184.1426 Section 184.1426 Food... Specific Substances Affirmed as GRAS § 184.1426 Magnesium chloride. (a) Magnesium chloride (MgC12·6H2O, CAS... hydrochloric acid solution and crystallizing out magnesium chloride hexahydrate. (b) The ingredient meets the...

  9. Radium and thorium with barium in micronodules of cattle thyroids

    International Nuclear Information System (INIS)

    Van Middlesworth, L.

    1980-01-01

    Radium isotopes were found concentrated in thyroid glands of cattle. The incidence of measurable radium varied from 80% to less than 0.1% in thyroids from different abattoirs. The radium was concentrated in microscopic bodies containing predominantly barium and sulfur and lying within the storage of thyroglobulin, adjacent to follicular cells. Some thyroid cells may receive biologically significant doses of alpha radiation from these sources

  10. Preparation of barium and uranium targets on thick backings

    International Nuclear Information System (INIS)

    Sletten, G.

    1982-01-01

    Targets of 135 Ba and 235 U have been prepared by the technique of heavy ion sputtering. Rolled foils of 208 Pb and 197 Au were used to support 250-500 μg/cm 2 layers of barium. Uranium films have been prepared by sputtering UO 2 onto 1 mg/cm 2 titanium foils. Uranium deposit thicknesses of 300 to 1800 μg/cm 2 have been prepared. (orig.)

  11. Barium enema and CT findings of Douglas pouch metastasis

    International Nuclear Information System (INIS)

    Miyakawa, Kunihisa; Uchiyama, Nachiko; Iinuma, Hajime; Moriyama, Noriyuki

    1999-01-01

    We retrospectively reviewed barium enema and CT findings of Douglas pouch metastasis in 170 patients. The findings were divided into three types: Anterior compression type, anterior fixed folds type, and stenosis type. Patients with gastric cancer usually showed a stenosis type, especially in those with poorly differentiated adenocarcinoma. Patients with colon and ovary cancer usually showed an anterior compression type. In patients with gastric cancer, those who showed a stenosis type had the most favorable prognosis among these three types. (author)

  12. Synthesis and characterization of barium ferrite–silica nanocomposites

    International Nuclear Information System (INIS)

    Aguilar-González, M.A.; Mendoza-Suárez, G.; Padmasree, K.P.

    2013-01-01

    In this work, we prepared barium ferrite-silica (BaM-SiO 2 ) nanocomposites of different molar ratios by high-energy ball milling, followed by heat-treatment at different temperatures. The microstructure, morphology and magnetic properties were characterized for different synthesis conditions by using X-ray diffraction (XRD), scanning electron microscopy (SEM) and vibrating sample magnetometry (VSM). The results indicate that 15 h of milling was enough to avoid the generation of hematite phase and to get a good dispersion of barium ferrite particles in the ceramic matrix. For milling periods beyond 15 h and heat treatment above 900 °C, the XRD patterns showed the presence of hematite phase caused by the decomposition of BaM. The agglomerate size observed through SEM analysis was around 150 nm with a good BaM dispersion into the SiO 2 matrix. The highest saturation magnetization (Ms) value obtained was 43 emu/g and the corresponding coercivity (Hc) value of 3.4 kOe for the composition 60BaM-40SiO 2 milled for 15 h and heat treated at 900 °C. This coercivity value is acceptable for the application in magnetic recording media. Highlights: • Barium ferrite–silica nanocomposites were prepared by high energy ball milling. • Optimal processing time is 15 h milling and heat treatment at 900 °C. • This is enough to avoid the generation of hematite phase. • Obtain good dispersion of barium ferrite particles in the ceramic matrix • Above this processing time shows the presence of increased amount of hematite

  13. Optical and luminescent properties of the lead and barium molybdates

    Energy Technology Data Exchange (ETDEWEB)

    Spassky, D.A. E-mail: dima@opts.phys.msu.ru; Ivanov, S.N.; Kolobanov, V.N.; Mikhailin, V.V.; Zemskov, V.N.; Zadneprovski, B.I.; Potkin, L.I

    2004-12-01

    Time-resolved luminescence as well as excitation and reflectivity spectra of the oriented lead and barium molybdate single crystals were studied using synchrotron radiation. Features in reflectivity spectra in the fundamental absorption region were analyzed. The contribution of electronic states of lead cation to the formation of the bandgap in PbMoO{sub 4} is supposed. The role of lead states in the intrinsic luminescence of PbMoO{sub 4} is discussed.

  14. Clinical efficacy of a new barium sulfate for abdominal CT

    International Nuclear Information System (INIS)

    Yamada, Tatuya; Kohno, Mitio; Uematsu, Sadao; Nisitani, Hiromu; Tanaka, Takao.

    1988-01-01

    Computed Tomography of the abdomen requires that the intestines are filled with contrast medium so that the gut is not misinterpreted as a pathologic process. Besides, normal structures may be difficult to delimit in patients with scanty intra-abdominal fat. In Japan, up to date, only a single contrast medium has been available for this purpose, Gastrografin and thus identical with the intravasculaly used Urografin or Angiografin. A new Barium Sulfate suspention (Fusimi Seiyaku, Kagawa) for computed tomographic use has been dilute solution (4.77 %) and with suspending agents that prevent a rapid sedimentation of the Barium Sulfate. The aim of this investigation was to compare Gastrografin with a new barium regarding patients tolerance, side effects and diagnostic information. The investigation comprised 146 patients who were reffered for abdominal CT and was carried out by 5 facilities; National Cancer Center, Kobe University, Chiba University, Kyushu University and Juntendo University. Diagnostic information was judged with respect to the filling of the stomach and intestines, the presence of imaging artifacts and finally clinical estimation. Patients tolerance was investigated as regards taste and side effects. Good filling of the stomach and intestines was obtained in this investigation. However, imaging artifacts occured in only a few cases. The imaging artifacts appeared almost exclusively to arise in the boundary layer between the bowel gas and contrast medium, and were most common in the stomach. However, the contrasting effect of this medium did not in itself appear to cause any imaging artifacts. Fushimi's new barium seems to be preffered because of its lesser tendency to arise artifacts and better tendency to make good filling of the stomach and intestines. Moreover, this investigation did not have any side effects. (J.P.N.)

  15. Structure and multiferroic properties of barium hexaferrite ceramics

    International Nuclear Information System (INIS)

    Tan, Guolong; Chen, Xiuna

    2013-01-01

    Simultaneous occurrence of large ferroelectricity and strong ferromagnetism have been observed in barium hexaferrite ceramics. Barium hexaferrite (BaFe 12 O 19 ) powders with hexagonal crystal structure were successfully synthesized in a polymer precursor method using barium acetate and ferric acetylacetonate as the precursors. The powders were pressed into pellets which were sintered into ceramics at 1200 °C and 1300 °C for 1 h. The structure and morphology of the ceramics were examined using X-ray diffraction and field emission scanning electron microscopy. Large spontaneous polarization was observed in the BaFe 12 O 19 ceramics at room temperature, revealing a clear ferroelectric hysteresis loop. The maximum remanent polarization of the BaFe 12 O 19 ceramic was estimated approximately 11.8 μC cm −2 . The FeO 6 octahedron in its perovskite-like hexagonal unit cell and the shift of Fe 3+ off the center of octahedron are suggested to be the origin of the polarization in BaFe 12 O 19 . The BaFe 12 O 19 ceramics also showed strong ferromagnetism at room temperature. - Graphical abstract: Ferroelectric hysteresis loops of BaFe 12 O 19 ceramics measured at a frequency of 120 Hz, which shows that the ceramics sintered at 1200 °C is ferroelectric with P r ∼11.8 μC/cm 2 . Highlights: ► Large ferroelectricity and strong ferromagnetism were observed in barium hexaferrite ceramics. ► The maximum remanent polarization of the BaFe 12 O 19 ceramic was estimated to be 11.8 μC cm −2 . ► The FeO 6 octahedron and off-center shift of Fe 3+ are suggested to be the origin of the polarization.

  16. Barium fluoride surface preparation, analysis and UV reflective coatings at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Wuest, C.R.

    1992-01-01

    Lawrence Livermore National Laboratory (LLNL) has begun a program of study on barium fluoride scintillating crystals for the Barium Fluoride Electromagnetic Calorimeter Collaboration. This program has resulted in a number of significant improvements in the mechanical processing, polishing and coating of barium fluoride crystals. Techniques have been developed using diamond-loaded pitch lapping that can produce 15 angstrom RMS surface finishes over large areas. These lapped surfaces have been shown to be crystalline using Rutherford Back-scattering (RBS). Also, special polishing fixtures have been designed based on mounting technology developed for the 1.1 m diameter optics used in LLNL's Nova Laser. These fixtures allow as many as five 25--50 cm long barium fluoride crystals to be polished and lapped at a time with the necessary tolerances for the 16,000 crystal Barium Fluoride Calorimeter. In addition, results will be presented on coating barium fluoride with UV reflective layers of magnesium fluoride and aluminum

  17. Early colon cancer : findings on double contrast barium enema

    International Nuclear Information System (INIS)

    Kim, Seung Kwon; Lim, Jae Hoon; Lee, Soon Jin; Lim, Hyo Keun

    1998-01-01

    The purpose of this study is to describe the radiologic findings of early colon cancer on double-contrast barium enema. We retrospectively reviewed the double-contrast barium enemas of eight patients (M:F = 6:2; mean age : 67 yrs; range : 48-77 yrs) who were pathologically proven to be early colon cancer. The location, size and gross morphology of lesions was evaluated using double-contrast barium enema, while depth of invasion, degree of differentiation, precancerous lesions and lymph node metastasis were evaluated histopathologically. Early colon cancer was found in the rectum (n=4), sigmoid colon (n=3) and ascending colon (n=1). The size of mass ranged from 2.3 ∼ 8.3 (mean, 4.6) cm. And the polypoid type was most common (n=7); this was subdivided into sessile (Is, n=5), semipedunculated (Isp, n=1) and pedunculated type (Ip, n=1). Another mass was a sessile polypoid combined with a flat depressed lesion. In eight cases, four cancers were confined to the mucosa, while the remaining four had infiltrated the submucosa. Most cancers arose from villous and villotubular adenoma. All cases were well-differentiated adenocarcinoma and no metastasis to lymph nodes had occurred. In early colon cancer, lesions were mainly polypoid and large. Most arose from villous and villotubular adenoma. (author). 19 refs., 1 tab., 3 figs

  18. Complications from radiographer-performed double contrast barium enemas

    Energy Technology Data Exchange (ETDEWEB)

    Vora, P.; Chapman, A. E-mail: anthony.chapman@leedsth.nhs.uk

    2004-04-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted.

  19. Complications from radiographer-performed double contrast barium enemas

    International Nuclear Information System (INIS)

    Vora, P.; Chapman, A.

    2004-01-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted

  20. Microwave-hydrothermal synthesis of barium strontium titanate nanoparticles

    International Nuclear Information System (INIS)

    Simoes, A.Z.; Moura, F.; Onofre, T.B.; Ramirez, M.A.; Varela, J.A.; Longo, E.

    2010-01-01

    Research highlights: → Barium strontium titanate nanoparticles were obtained by the Hydrothemal microwave technique (HTMW) → This is a genuine technique to obtain nanoparticles at low temperature and short times → Barium strontium titanate free of carbonates with tetragonal structure was grown at 130 o C. - Abstract: Hydrothermal-microwave method (HTMW) was used to synthesize crystalline barium strontium titanate (Ba 0.8 Sr 0.2 TiO 3 ) nanoparticles (BST) in the temperature range of 100-130 o C. The crystallization of BST with tetragonal structure was reached at all the synthesis temperatures along with the formation of BaCO 3 as a minor impurity at lower syntheses temperatures. Typical FT-IR spectra for tetragonal (BST) nanoparticles presented well defined bands, indicating a substantial short-range order in the system. TG-DTA analyses confirmed the presence of lattice OH- groups, commonly found in materials obtained by HTMW process. FE/SEM revealed that lower syntheses temperatures led to a morphology that consisted of uniform grains while higher syntheses temperature consisted of big grains isolated and embedded in a matrix of small grains. TEM has shown BST nanoparticles with diameters between 40 and 80 nm. These results show that the HTMW synthesis route is rapid, cost effective, and could serve as an alternative to obtain BST nanoparticles.

  1. Spectrophotometry of barium, CH, and R-type carbon stars

    International Nuclear Information System (INIS)

    Gow, C.E.

    1976-01-01

    Observations of 35 barium, CH, R, and hydrogen-deficient carbon stars, along with ten comparison K giants, have been made with the Indiana rapid spectrum scanner and the Indiana SIT vidicon spectrometer. The scanner observations cover a wavelength range of 3300--7000 A at 30-A resolution, while the SIT vidicon observations cover a wavelength range of 3800--5000 A at 2.5-A resolution. The data have been used to form molecular indices for a quantitative measurement of the strength of molecular features appearing in this region of the spectrum, and to compare the spectral energy distribution of carbon and oxygen stars over the entire observed wavelength range. We find the C 2 Swan index correlated strongly with both the strength of an unidentified feature centered near 4000 A, and the barium-to-hydrogen ratio. A detailed comparison of the spectral energy distribution of the barium stars with normal K giants shows that this unidentified absorption feature consists of two shallows depressions, one at 4000 A and another at 4325 A

  2. Barium as a potential indicator of phosphorus in agricultural runoff.

    Science.gov (United States)

    Ahlgren, Joakim; Djodjic, Faruk; Wallin, Mats

    2012-01-01

    In many catchments, anthropogenic input of contaminants, and in particular phosphorus (P), into surface water is a mixture of agricultural and sewage runoff. Knowledge about the relative contribution from each of these sources is vital for mitigation of major environmental problems such as eutrophication. In this study, we investigated whether the distribution of trace elements in surface waters can be used to trace the contamination source. Water from three groups of streams was investigated: streams influenced only by agricultural runoff, streams influenced mainly by sewage runoff, and reference streams. Samples were collected at different flow regimes and times of year and analyzed for 62 elements using ICP-MS. Our results show that there are significant differences between the anthropogenic sources affecting the streams in terms of total element composition and individual elements, indicating that the method has the potential to trace anthropogenic impact on surface waters. The elements that show significant differences between sources are strontium (p barium (p barium shows the greatest potential as a tracer for an individual source of anthropogenic input to surface waters. We observed a strong relationship between barium and total P in the investigated samples (R(2) = 0.78), which could potentially be used to apportion anthropogenic sources of P and thereby facilitate targeting of mitigation practices. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  3. 46 CFR 151.50-34 - Vinyl chloride (vinyl chloride monomer).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Vinyl chloride (vinyl chloride monomer). 151.50-34... chloride (vinyl chloride monomer). (a) Copper, aluminum, magnesium, mercury, silver, and their alloys shall... equipment that may come in contact with vinyl chloride liquid or vapor. (b) Valves, flanges, and pipe...

  4. 40 CFR 61.65 - Emission standard for ethylene dichloride, vinyl chloride and polyvinyl chloride plants.

    Science.gov (United States)

    2010-07-01

    ... dichloride, vinyl chloride and polyvinyl chloride plants. 61.65 Section 61.65 Protection of Environment... AIR POLLUTANTS National Emission Standard for Vinyl Chloride § 61.65 Emission standard for ethylene dichloride, vinyl chloride and polyvinyl chloride plants. An owner or operator of an ethylene dichloride...

  5. Strontium-90 sorption from fresh waters in the process of barium manganite modification

    International Nuclear Information System (INIS)

    Ryzhen'kov, A.P.; Egorov, Yu.V.

    1995-01-01

    Strontium-90 extraction by barium manganite from fresh water (natural non-salty water in open ponds) may be increased adding to the solution the sulfate anion containing reagents that modify a sorbent and chemically bind a sorbate. Heterogeneous anion-exchanging reaction of barium manganite transformation into barium sulfate-manganese dioxide and simultaneous coprecipitation of strontium sulfate (microelement) occur as a result of it. 9 refs., 4 figs., 1 tab

  6. Simplified assessment of segmental gastrointestinal transit time with orally small amount of barium

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Weitang; Zhang, Zhiyong; Liu, Jinbo; Li, Zhen; Song, Junmin; Wu, Changcai [Department of Colorectal Surgery, The First Affiliated Hospital and Institute of Clinical Medicine, Zhengzhou University, 450052 Zhengzhou (China); Wang, Guixian, E-mail: guixianwang@hotmail.com [Department of Colorectal Surgery, The First Affiliated Hospital and Institute of Clinical Medicine, Zhengzhou University, 450052 Zhengzhou (China)

    2012-09-15

    Objective: To determine the effectiveness and advantage of small amount of barium in the measurement of gastrointestinal transmission function in comparison with radio-opaque pallets. Methods: Protocal 1: 8 healthy volunteers (male 6, female 2) with average age 40 ± 6.1 were subjected to the examination of radio-opaque pellets and small amount of barium with the interval of 1 week. Protocol 2: 30 healthy volunteers in group 1 (male 8, female 22) with average age 42.5 ± 8.1 and 50 patients with chronic functional constipation in group 2 (male 11, female 39) with average age 45.7 ± 7.8 were subjected to the small amount of barium examination. The small amount of barium was made by 30 g barium dissolved in 200 ml breakfast. After taking breakfast which contains barium, objectives were followed with abdominal X-ray at 4, 8, 12, 24, 48, 72, 96 h until the barium was evacuated totally. Results: Small amount of barium presented actual chyme or stool transit. The transit time of radio-opaque pallets through the whole gastrointestinal tract was significantly shorter than that of barium (37 ± 8 h vs. 47 ± 10 h, P < 0.05) in healthy people. The transit times of barium in constipation patients were markedly prolonged in colon (61.1 ± 22 vs. 37.3 ± 11, P < 0.01) and rectum (10.8 ± 3.7 vs. 2.3 ± 0.8 h, P < 0.01) compared with unconstipated volunteers. Transit times in individual gastrointestinal segments were also recorded by using small amount of barium, which allowed identifying the subtypes of constipation. Conclusion: The small amount barium examination is a convenient and low cost method to provide the most useful and reliable information on the transmission function of different gastrointestinal segments and able to classify the subtypes of slow transit constipation.

  7. A Comparative Study on Magnetostructural Properties of Barium Hexaferrite Powders Prepared by Polyethylene Glycol

    OpenAIRE

    Zehra Durmus

    2014-01-01

    Nanocrystalline particles of barium hexaferrite were synthesized by a sol-gel combustion route using nitrate-citrate gels prepared from metal nitrates and citric acid solutions with Fe/Ba molar ratio 12. The present paper aims to study the effect of addition of polyethylene glycol (PEG) solutions with different molecular weights (MW: 400, 2000, and 10.000 g/mol) on magnetostructural properties of barium hexaferrite. The formation of the barium hexaferrite was inspected using X-ray diffractio...

  8. Aspiration of barium contrast medium in an elderly man with disordered swallowing

    OpenAIRE

    Bağcı Ceyhan, B.; Çelikel, T.; Koç, M.; Ahıskalı, R.; Biren, T.; Ataizi Çelikel, Ç.

    1995-01-01

    The aspiration of contrast medium during the investigation of gastrointestinal diseases is a well recognized hazard, particularly in patients with swallowing disorders. A case is reported in which accidental aspiration of contrast barium occurred owing to disordered swallowing in an elderly man. The infiltration on chest x-ray persisted 2 years after barium contrast aspiration. Inflammatory reaction and retractile, granular material observed in lung biopsy specimens suggested barium-induced p...

  9. Simplified assessment of segmental gastrointestinal transit time with orally small amount of barium

    International Nuclear Information System (INIS)

    Yuan, Weitang; Zhang, Zhiyong; Liu, Jinbo; Li, Zhen; Song, Junmin; Wu, Changcai; Wang, Guixian

    2012-01-01

    Objective: To determine the effectiveness and advantage of small amount of barium in the measurement of gastrointestinal transmission function in comparison with radio-opaque pallets. Methods: Protocal 1: 8 healthy volunteers (male 6, female 2) with average age 40 ± 6.1 were subjected to the examination of radio-opaque pellets and small amount of barium with the interval of 1 week. Protocol 2: 30 healthy volunteers in group 1 (male 8, female 22) with average age 42.5 ± 8.1 and 50 patients with chronic functional constipation in group 2 (male 11, female 39) with average age 45.7 ± 7.8 were subjected to the small amount of barium examination. The small amount of barium was made by 30 g barium dissolved in 200 ml breakfast. After taking breakfast which contains barium, objectives were followed with abdominal X-ray at 4, 8, 12, 24, 48, 72, 96 h until the barium was evacuated totally. Results: Small amount of barium presented actual chyme or stool transit. The transit time of radio-opaque pallets through the whole gastrointestinal tract was significantly shorter than that of barium (37 ± 8 h vs. 47 ± 10 h, P < 0.05) in healthy people. The transit times of barium in constipation patients were markedly prolonged in colon (61.1 ± 22 vs. 37.3 ± 11, P < 0.01) and rectum (10.8 ± 3.7 vs. 2.3 ± 0.8 h, P < 0.01) compared with unconstipated volunteers. Transit times in individual gastrointestinal segments were also recorded by using small amount of barium, which allowed identifying the subtypes of constipation. Conclusion: The small amount barium examination is a convenient and low cost method to provide the most useful and reliable information on the transmission function of different gastrointestinal segments and able to classify the subtypes of slow transit constipation

  10. 21 CFR 184.1297 - Ferric chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ferric chloride. 184.1297 Section 184.1297 Food and... Substances Affirmed as GRAS § 184.1297 Ferric chloride. (a) Ferric chloride (iron (III) chloride, FeC13, CAS Reg. No. 7705-08-0) may be prepared from iron and chlorine or from ferric oxide and hydrogen chloride...

  11. Preparation of pure anhydrous rare earth chlorides

    International Nuclear Information System (INIS)

    Bel'kova, N.L.; Slastenova, N.M.; Batyaev, I.M.; Solov'ev, M.A.

    1979-01-01

    A method has been suggested for obtaining extra-pure anhydrous REE chlorides by chloridizing corresponding oxalates by chlorine in a fluid bed, the chloridizing agents being diluted by an inert gas in a ratio of 2-to-1. The method is applicable to the manufacture of quality chlorides not only of light, but also of heavy REE. Neodymium chloride has an excited life of tau=30 μs, this evidencing the absence of the damping impurities

  12. Oxidation of dibenzothiophene as a model substrate for the removal of organic sulphur from fossil fuels by iron(III ions generated from pyrite by Acidithiobacillus ferrooxidans

    Directory of Open Access Journals (Sweden)

    VLADIMIR P. BESKOSKI

    2007-06-01

    Full Text Available Within this paper a new idea for the removal of organically bonded sulphur from fossil fuels is discussed. Dibenzothiophene (DBT was used as a model compound of organicmolecules containing sulphur. This form of (biodesulphurization was performed by an indirect mechanism in which iron(III ions generated from pyrite by Acidithiobacillus ferrooxidans performed the abiotic oxidation. The obtained reaction products, dibenzothiopene sulfoxide and dibenzothiophene sulfone, are more soluble in water than the basic substrate and the obtained results confirmed the basic hypothesis and give the posibility of continuing the experiments related to application of this (biodesulphurization process.

  13. Results of a cooperative study for the evaluation of the barium meal Falibaryt HD

    International Nuclear Information System (INIS)

    Reisinger, W.; Liess, G.; Beckmann, D.; Block, H.G.; Dietze, R.; Grosche, N.; Hall, E.; Lasch, G.; Knoth, H.J.; Kroeger, W.

    1986-01-01

    The diagnostic capabilities of radiologic investigations of the stomach in double contrast can be significantly improved with high-density low-viscosity barium meals. In the GDR the barium meal Falibaryt HD with a barium sulfate content of 215 g per 100 ml suspension has been developed. In nearly 1,000 radiologic investigations of the stomach (81% in relaxation with spasmolytics, 66% without hypotony) all fine structures were well imaged and the preparation therefore is comparable with the best barium meals presently on the market. (author)

  14. Effects of powdered versus liquid barium on the viscosity of fluids used in modified swallow studies

    International Nuclear Information System (INIS)

    Baron, J.; Alexander, T.

    2003-01-01

    To determine if the viscosity of thickened juice mixtures used in modified barium swallow studies significantly changes with the addition of powdered barium. We also describe a test formulation created using liquid barium, which has a negligible effect on juice viscosity. The viscosities of water and standardized honey- and nectar-consistency juices mixed with different amounts of powdered barium were measured by timing the laminar flow of a given initial hydrostatic head of fluid under gravity though an orifice of fixed diameter. Standardized juices were then mixed with a liquid formulation of barium and with measured quantities of water to produce viscosities that more closely equated with those of the standardized juices. With the addition of powdered barium, viscosity increased in all fluids, most markedly with the nectar-consistency juice. Liquid barium formulations maintained the viscosities of the original thickened juices. Rendering juices radio-opaque with barium powder results in dramatic increases in the viscosity of the resulting mixture and compromises diagnostic accuracy. Liquid barium preparations have the advantage that they can be rapidly and accurately dispensed by syringe, and their use does not significantly increase the viscosity of the preparation. (author)

  15. Effects of powdered versus liquid barium on the viscosity of fluids used in modified swallow studies

    Energy Technology Data Exchange (ETDEWEB)

    Baron, J.; Alexander, T. [Univ. of Alberta, Dept. of Radiology, Edmonton, Alberta (Canada)

    2003-06-01

    To determine if the viscosity of thickened juice mixtures used in modified barium swallow studies significantly changes with the addition of powdered barium. We also describe a test formulation created using liquid barium, which has a negligible effect on juice viscosity. The viscosities of water and standardized honey- and nectar-consistency juices mixed with different amounts of powdered barium were measured by timing the laminar flow of a given initial hydrostatic head of fluid under gravity though an orifice of fixed diameter. Standardized juices were then mixed with a liquid formulation of barium and with measured quantities of water to produce viscosities that more closely equated with those of the standardized juices. With the addition of powdered barium, viscosity increased in all fluids, most markedly with the nectar-consistency juice. Liquid barium formulations maintained the viscosities of the original thickened juices. Rendering juices radio-opaque with barium powder results in dramatic increases in the viscosity of the resulting mixture and compromises diagnostic accuracy. Liquid barium preparations have the advantage that they can be rapidly and accurately dispensed by syringe, and their use does not significantly increase the viscosity of the preparation. (author)

  16. Barium and Tc-poor S stars: Binary masqueraders among carbon stars

    OpenAIRE

    Jorissen, A.; Van Eck, S.

    1997-01-01

    The current understanding of the origin of barium and S stars is reviewed, based on new orbital elements and binary frequencies. The following questions are addressed: (i) Is binarity a necessary condition to produce a barium star? (ii) What is the mass transfer mode (wind accretion or RLOF?) responsible for their formation? (iii) Do barium stars form as dwarfs or as giants? (iv) Do barium stars evolve into Tc-poor S stars? (v) What is the relative frequency of Tc-rich and Tc-poor S stars?

  17. Prompt striations observed in a barium thermite release at 335 km

    International Nuclear Information System (INIS)

    Simons, D.J.; Pongratz, M.B.; Smith, G.M.; Barasch, G.E.; Fitzgerald, T.J.

    1981-01-01

    Three barium clouds have been released from a single rocket at altitudes of 335, 443, and 535 km. The releases were by means of barium thermite injection. Adding the different cross-field velocity components of the rocket at each of the releases resulted in barium clouds with different kinetic velocity distributions. The barium cloud with the most peaked velocity distribution striated promptly, in good agreement with theoretical predictions based on a kinetic plasma instability. Details of the data analysis and experiment are discussed

  18. Radiation losses in microwave K_u region by conducting pyrrole/barium titanate and barium hexaferrite based nanocomposites

    International Nuclear Information System (INIS)

    Kaur, Talwinder; Kumar, Sachin; Narang, S.B.; Srivastava, A.K.

    2016-01-01

    Nanocomposites of substituted barium hexaferrite and barium titanate embedded in a polymer were synthesized via emulsion polymerization. The study was performed by using X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy, electron spin resonance spectroscopy, a vibrating sample magnetometer and a vector network analyzer. It is found that maximum radiation loss occur at 16.09 GHz (−14.23 dB) frequency owing to the combined effect of conducting polymer, suitable dielectric and magnetic material. This suggests that prepared material is suitable for radiation losses. Micro structural study reveals the presence of all the phases of the compounds comprises composite. Benzene ring absorption band (at 1183 cm"−"1) in FT-IR spectra illustrates the presence of polymer. Surface morphology reveals the presence of array of particles encapsulated by the polymer. - Highlights: • Composites having polymer, barium titanate and hexaferrite have been successfully prepared. • Effective radiation absorption and losses have been achieved. • Magnetic properties have made an impact on shielding effectiveness.

  19. Radiation losses in microwave K{sub u} region by conducting pyrrole/barium titanate and barium hexaferrite based nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Talwinder [Department of Physics, Lovely Professional University, Phagwara 144411 (India); Kumar, Sachin [Department of Chemistry, Guru Nanak Dev University, Amritsar 143005 (India); Narang, S.B. [Department of Electronics Technology, Guru Nanak Dev University, Amritsar 143005 (India); Srivastava, A.K., E-mail: srivastava_phy@yahoo.co.in [Department of Physics, Lovely Professional University, Phagwara 144411 (India)

    2016-12-15

    Nanocomposites of substituted barium hexaferrite and barium titanate embedded in a polymer were synthesized via emulsion polymerization. The study was performed by using X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy, electron spin resonance spectroscopy, a vibrating sample magnetometer and a vector network analyzer. It is found that maximum radiation loss occur at 16.09 GHz (−14.23 dB) frequency owing to the combined effect of conducting polymer, suitable dielectric and magnetic material. This suggests that prepared material is suitable for radiation losses. Micro structural study reveals the presence of all the phases of the compounds comprises composite. Benzene ring absorption band (at 1183 cm{sup −1}) in FT-IR spectra illustrates the presence of polymer. Surface morphology reveals the presence of array of particles encapsulated by the polymer. - Highlights: • Composites having polymer, barium titanate and hexaferrite have been successfully prepared. • Effective radiation absorption and losses have been achieved. • Magnetic properties have made an impact on shielding effectiveness.

  20. Manganese associated nanoparticles agglomerate of iron(III) oxide: synthesis, characterization and arsenic(III) sorption behavior with mechanism.

    Science.gov (United States)

    Gupta, Kaushik; Maity, Arjun; Ghosh, Uday Chand

    2010-12-15

    Three samples of manganese associated hydrous iron(III) oxide (MNHFO), prepared by incinerating metal hydroxide precipitate at T (± 5)=90, 300 and 600°C, showed increase of crystalline nature in XRD patterns with decreasing As(III) removal percentages. TEM images showed the increase of crystallinity from sample-1 (MNHFO-1) to sample-3 (MNHFO-3). Dimensions (nm) of particles estimated were 5.0, 7.0 and 97.5. Optimization of pH indicated that MNHFO-1 could remove aqueous As(III) efficiently at pH between 3.0 and 7.0. Kinetic and equilibrium data of reactions under the experimental conditions described the pseudo-second order and the Langmuir isotherm equations very well, respectively. The Langmuir capacity (q(m)) estimated was 691.04 mmol kg(-1). The values of enthalpy, Gibb's free energy and entropy changes (ΔH(0)=+23.23 kJ mol(-1), ΔG(0)=-3.43 to -7.20 kJ mol(-1) at T=283-323K, ΔS(0)=+0.094 kJ mol(-1)K(-1)) suggested that the reaction was endothermic, spontaneous and took place with increasing entropy. The As(III) sorbed by MNHFO-1 underwent surface oxidation to As(V), and evidences appeared from the XPS and FTIR investigations. MNHFO-1 packed column (internal diameter: 1.0 cm, height: 3.7 cm) filtered 11.5 dm(3) groundwater (105 μg As dm(-3)) with reducing arsenic concentration to ≤ 10 μg dm(-3). Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Reaction of calcium chloride with alkali metal chlorides in melts

    International Nuclear Information System (INIS)

    Savin, V.D.; Mikhajlova, N.P.

    1984-01-01

    Thermochemical characteristics of CaCl 2 reaction with sodium, potassium, rubidium and cesium chlorides in melts at 890 deg C are determined. The values of formation enthalpies of infinitely diluted by CaCl 2 solutions (ΔH) in the chloride row increase from -22 in NaCl to -47 kJ/mol of CaCl 2 in CsCl. With increasing the concentration of calcium chloride in the solution the ΔH values decrease. The regularities of separation from the solution of the CaCl 2 -CsCl system at 890 deg C of the CaCl 2 x CsCl in solid are studied. Formation enthalpies under the given conditions constitutes -70+-3 kJ/mol

  2. Electrochemical Chloride extraction using external electrodes?

    DEFF Research Database (Denmark)

    Ottosen, Lisbeth M.; Pedersen, Anne Juul

    2006-01-01

    Electrochemical methods for the removal of chloride from concrete have been developed and the methods are primarily designed for situations where corrosion has started due to an increased chloride concentration in the vicinity of the reinforcement. In these methods the reinforcement is used...... as the cathode. However, some unwanted side effects can occur, including alkali-silica reaction and in some cases hydrogen embrittlement. It is also suggested also to use electrochemical chloride extraction in a preventive way in constructions where chloride induced corrosion is likely to be a problem after...... a period of time, i.e. remove the chlorides before the chloride front reaches the reinforcement. If the chlorides are removed from outer few centimetres from the surface, the chloride will not reach the reinforcement and cause damage. By using the electrochemical chloride removal in this preventive way...

  3. Precipitation method for barium metaborate (BaB{sub 2}O{sub 4}) synthesis from borax solution

    Energy Technology Data Exchange (ETDEWEB)

    Akşener, Eymen; Figen, Aysel Kantürk; Pişkin, Sabriye [Yildiz Technical University, Chem. Eng. Dept., Davutpasa Campus, 34210, Istanbul (Turkey)

    2013-12-16

    In this study, barium metaborate (BaB{sub 2}O{sub 4}, BMB) synthesis from the borax solution was carried out. BMB currently is used in production of ceramic glazes, luminophors, oxide cathodes as well as additives to pigments for aqueous emulsion paints and also β−BaB{sub 2}O{sub 4} single crystals are the best candidate for fabrication of solid-state UV lasers operating at a wavelength of 200 nm due to excellent nonlinear optical properties. In the present study, synthesis was carried out from the borax solution (Na{sub 2}B{sub 4}O{sub 7⋅}10H{sub 2}O, BDH) and barium chloride (BaCI{sub 2⋅}2H{sub 2}O, Ba) in the glass-batch reactor with stirring. The effect of, times (5-15 min), molar ratio [stoich.ration (1.0:2.0), 1.25:2.0, 1.5:2.0, 2.5:2:0, 3.0:2.0, 3.5:2.0,4.0:2.0, 5.0:2.0] and also crystallization time (2-6 hour) on the BMB yield (%) was investigated at 80 °C reaction temperature. It is found that, BMB precipitation synthesis with 90 % yield can be performed from 0.50 molar ration (BDH:Ba), under 80 °C, 15 minute, and 6 hours crystallization time. The structural properties of BMB powders were characterized by using XRD, FT-IR and DTA-TG instrumental analysis technique.

  4. A review of the health impacts of barium from natural and anthropogenic exposure.

    Science.gov (United States)

    Kravchenko, Julia; Darrah, Thomas H; Miller, Richard K; Lyerly, H Kim; Vengosh, Avner

    2014-08-01

    There is an increasing public awareness of the relatively new and expanded industrial barium uses which are potential sources of human exposure (e.g., a shale gas development that causes an increased awareness of environmental exposures to barium). However, absorption of barium in exposed humans and a full spectrum of its health effects, especially among chronically exposed to moderate and low doses of barium populations, remain unclear. We suggest a systematic literature review (from 1875 to 2014) on environmental distribution of barium, its bioaccumulation, and potential and proven health impacts (in animal models and humans) to provide the information that can be used for optimization of future experimental and epidemiological studies and developing of mitigative and preventive strategies to minimize negative health effects in exposed populations. The potential health effects of barium exposure are largely based on animal studies, while epidemiological data for humans, specifically for chronic low-level exposures, are sparse. The reported health effects include cardiovascular and kidney diseases, metabolic, neurological, and mental disorders. Age, race, dietary patterns, behavioral risks (e.g., smoking), use of medications (those that interfere with absorbed barium in human organism), and specific physiological status (e.g., pregnancy) can modify barium effects on human health. Identifying, evaluating, and predicting the health effects of chronic low-level and moderate-level barium exposures in humans is challenging: Future research is needed to develop an understanding of barium bioaccumulation in order to mitigate its potential health impacts in various exposured populations. Further, while occupationally exposed at-risk populations exist, it is also important to identify potentially vulnerable subgroups among non-occupationally exposed populations (e.g., elderly, pregnant women, children) who are at higher risk of barium exposure from drinking water and food.

  5. The diagnosis of gastro-esophageal reflux disease cannot be made with barium esophagograms.

    Science.gov (United States)

    Saleh, C M G; Smout, A J P M; Bredenoord, A J

    2015-02-01

    For over 50 years, barium studies have been used to diagnose gastro-esophageal reflux disease (GERD), but the value of this test is controversial. Our study aimed to determine if barium esophagograms can be used to diagnose GERD. Barium esophagograms and pH-impedance measurement were performed in 20 subjects with reflux symptoms. pH-impedance measurements were used as gold standard for the diagnosis of GERD. Gastro-esophageal reflux measured with the barium study was defined as a positive outcome. 50% of patients presented gastro-esophageal reflux on the barium esophagogram. No significant differences were observed in acid exposure time between subjects with (median: 7.4%; interquartile range, IQR: 8.4%) or without reflux at barium esophagography (median: 5.95%; IQR: 13.05%; p > 0.05). Nor did we find differences in median proximal extent of reflux measured with impedance monitoring between patients with a positive (median: 6.7%; IQR: 1.95%) and negative barium study (median: 7.1%; IQR: 0.68%; p > 0.05). Patients with reflux on barium esophagogram did not have a positive symptom association probability more often than those who did not have reflux at barium esophagography. Lastly, there were no differences in numbers of acid, weakly acidic or total reflux episodes between those with positive or negative barium esophagogram (p > 0.05). No correlations were found between the maximum proximal extent of gastro-esophageal reflux during esophagography and pH-impedance parameters. Presence or absence of gastro-esophageal reflux during barium esophagography does not correlate with incidence or extent of reflux observed during 24-h pH-impedance monitoring and is not of value for the diagnosis of GERD. © 2014 John Wiley & Sons Ltd.

  6. Spectroscopic, potentiometric and theoretical studies on the binding properties of a novel tripodal polycatechol-imine ligand towards iron(III)

    Science.gov (United States)

    Kanungo, B. K.; Sahoo, Suban K.; Baral, Minati

    2008-12-01

    A novel multidentate tripodal ligand, cis, cis-1,3,5-tris[(2,3-dihydroxybenzylidene)aminomethyl]cyclohexane (TDBAC, L) containing one catechol unit in each arms of a tripodal amine, cis, cis-1,3,5-tris(aminomethyl)cyclohexane was investigated as a chelator for iron(III) through potentiometric and spectrophotometric methods in an aqueous medium of 0.1N ionic strength and 25 ± 1 °C as well as in ethanol by continuous variation method. From pH metric in water, three protonation constants characterized for the three-hydroxyl groups of the catechol units at ortho were used as input data to evaluate the stability constants of the complexes. Formation of monomeric complexes FeLH 3, FeLH 2, FeLH and FeL were depicted. In ethanol, formation of complexes FeL, Fe 2L and Fe 3L were characterized. Structures of the complexes were explained by using the experimental evidences and predicted through molecular modeling calculations. The ligand showed potential to coordinate iron(III) through three imine nitrogens and three catecholic oxygens at ortho to form a tris(iminocatecholate) type complex.

  7. Coumarin-Based Fluorescent Probes for Dual Recognition of Copper(II and Iron(III Ions and Their Application in Bio-Imaging

    Directory of Open Access Journals (Sweden)

    Olimpo García-Beltrán

    2014-01-01

    Full Text Available Two new coumarin-based “turn-off” fluorescent probes, (E-3-((3,4-dihydroxybenzylideneamino-7-hydroxy-2H-chromen-2-one (BS1 and (E-3-((2,4-dihydroxybenzylideneamino-7-hydroxy-2H-chromen-2-one (BS2, were synthesized and their detection of copper(II and iron(III ions was studied. Results show that both compounds are highly selective for Cu2+ and Fe3+ ions over other metal ions. However, BS2 is detected directly, while detection of BS1 involves a hydrolysis reaction to regenerate 3-amino-7-hydroxycoumarin (3 and 3,4-dihydroxybenzaldehyde, of which 3 is able to react with copper(II or iron(III ions. The interaction between the tested compounds and copper or iron ions is associated with a large fluorescence decrease, showing detection limits of ca. 10−5 M. Preliminary studies employing epifluorescence microscopy demonstrate that Cu2+ and Fe3+ ions can be imaged in human neuroblastoma SH-SY5Y cells treated with the tested probes.

  8. Anion and cation diffusion in barium titanate and strontium titanate

    International Nuclear Information System (INIS)

    Kessel, Markus Franz

    2012-01-01

    Perovskite oxides show various interesting properties providing several technical applications. In many cases the defect chemistry is the key to understand and influence the material's properties. In this work the defect chemistry of barium titanate and strontium titanate is analysed by anion and cation diffusion experiments and subsequent time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reoxidation equation for barium titanate used in multi-layer ceramic capacitors (MLCCs) is found out by a combination of different isotope exchange experiments and the analysis of the resulting tracer diffusion profiles. It is shown that the incorporation of oxygen from water vapour is faster by orders of magnitude than from molecular oxygen. Chemical analysis shows the samples contain various dopants leading to a complex defect chemistry. Dysprosium is the most important dopant, acting partially as a donor and partially as an acceptor in this effectively acceptor-doped material. TEM and EELS analysis show the inhomogeneous distribution of Dy in a core-shell microstructure. The oxygen partial pressure and temperature dependence of the oxygen tracer diffusion coefficients is analysed and explained by the complex defect chemistry of Dy-doped barium titanate. Additional fast diffusion profiles are attributed to fast diffusion along grain boundaries. In addition to the barium titanate ceramics from an important technical application, oxygen diffusion in cubic, nominally undoped BaTiO 3 single crystals has been studied by means of 18 O 2 / 16 O 2 isotope exchange annealing and subsequent determination of the isotope profiles in the solid by ToF-SIMS. It is shown that a correct description of the diffusion profiles requires the analysis of the diffusion through the surface space-charge into the material's bulk. Surface exchange coefficients, space-charge potentials and bulk diffusion coefficients are analysed as a function of oxygen partial pressure and temperature. The

  9. Standardization of NaI gamma spectrometer using a newly developed standard for the estimation of 228Ra in rare earth chloride solution

    International Nuclear Information System (INIS)

    Sahu, A.; Patra, R.P.; Jha, S.K.; Tripathi, R.M.; Patro, P.

    2018-01-01

    Monazite is a naturally occurring mineral which is a phosphate of various rare earths and thorium with traces of uranium. Indian Rare Earths Limited has set up a Monazite Processing Plant (MoPP) at Orissa Sand Complex (OSCOM), Odisha for recovery of various elements from Monazite. The finely ground monazite is processed with hot NaOH to separate the phosphate component as Tri-Sodium Phosphate from the mixed hydroxide. Then the mixed hydroxide is treated with HCl at controlled pH to separate rare earth as rare earth chloride solution. The rare earth chloride solution also contains 228 Ra which is generated in the 232 Th decay series. The rare earth chloride solution is then treated with BaCl 2 , MgSO 4 and Na 2 S; 228 Ra gets co-precipitated with Ba as Lead-Barium Sulfate. To meet the regulatory requirement, 228 Ra activity is reduced to below 1 Bq/g limit

  10. Thermal evolution of exchange interactions in lightly doped barium hexaferrites

    Energy Technology Data Exchange (ETDEWEB)

    Trukhanov, S.V., E-mail: truhanov@ifttp.bas-net.by [National University of Science and Technology MISiS, Leninsky Prospekt, 4, 119049 Moscow (Russian Federation); SSPA “Scientific and practical materials research centre of NAS of Belarus”, P. Brovki Str., 19, 220072 Minsk, Belorussia (Belarus); Trukhanov, A.V. [National University of Science and Technology MISiS, Leninsky Prospekt, 4, 119049 Moscow (Russian Federation); SSPA “Scientific and practical materials research centre of NAS of Belarus”, P. Brovki Str., 19, 220072 Minsk, Belorussia (Belarus); Kostishyn, V.G.; Panina, L.V. [National University of Science and Technology MISiS, Leninsky Prospekt, 4, 119049 Moscow (Russian Federation); Turchenko, V.A. [Joint Institute for Nuclear Research, Joliot-Curie Str., 141980 Dubna (Russian Federation); Donetsk Institute of Physics and Technology named after A.A. Galkin of the NAS of Ukraine, 72 R.Luxemburg Str., 83114 Donetsk (Ukraine); Kazakevich, I.S. [SSPA “Scientific and practical materials research centre of NAS of Belarus”, P. Brovki Str., 19, 220072 Minsk, Belorussia (Belarus); Trukhanov, An.V. [National University of Science and Technology MISiS, Leninsky Prospekt, 4, 119049 Moscow (Russian Federation); SSPA “Scientific and practical materials research centre of NAS of Belarus”, P. Brovki Str., 19, 220072 Minsk, Belorussia (Belarus); Trukhanova, E.L.; Natarov, V.O. [SSPA “Scientific and practical materials research centre of NAS of Belarus”, P. Brovki Str., 19, 220072 Minsk, Belorussia (Belarus); Balagurov, A.M. [Joint Institute for Nuclear Research, Joliot-Curie Str., 141980 Dubna (Russian Federation)

    2017-03-15

    The lightly doped BaFe{sub 12−x}D{sub x}O{sub 19} (D=Al{sup 3+}, In{sup 3+}; x=0.1 and 0.3) polycrystalline hexaferrite samples have been investigated by powder neutron diffractometry as well as by vibration sample magnetometry in a wide temperature range from 4 K up to 740 K and in magnetic field up to 14 T to establish the nature of Fe{sup 3+}(Al{sup 3+}, In{sup 3+}) – O{sup 2-} - Fe{sup 3+}(Al{sup 3+}, In{sup 3+}) indirect exchange interactions. The crystal structure features such as the ionic coordinates and lattice parameters have been defined and Rietveld refined. The Invar effect has been observed in low temperature range below 150 K. It was explained by the thermal oscillation anharmonicity of ions. It is established that the ferrimagnet-paramagnet phase transition is a standard second-order one. From the macroscopic magnetization measurement the Curie temperature and ordered magnetic moment per nominal iron ion are obtained. From the microscopic diffraction measurement the magnetic moments at all the nonequivalent ionic positions and total magnetic moment per iron ion have been obtained at different temperatures down to 4 K. The light diamagnetic doping mechanism and magnetic structure model are proposed. The effect of light diamagnetic doping on nature of Fe{sup 3+}(Al{sup 3+}, In{sup 3+}) – O{sup 2-} - Fe{sup 3+}(Al{sup 3+}, In{sup 3+}) indirect exchange interactions with temperature increase is discussed. - Highlights: • Crystal structure for lightly doped barium hexaferrites was investigated. • Atomic coordinates and lattice parameters were Rietveld refined. • Magnetic properties for lightly doped barium hexaferrites was investigated. • Magnetic structure for lightly doped barium hexaferrites was investigated. • Magnetic moments at different position and total moment per iron ion were defined.

  11. Multiple electrical phase transitions in Al substituted barium hexaferrite

    Science.gov (United States)

    Kumar, Sunil; Supriya, Sweety; Kar, Manoranjan

    2017-12-01

    Barium hexaferrite is known to be a very good ferromagnetic material. However, it shows very good dielectric properties, i.e., the dielectric constant is comparable to that of the ferroelectric material. However, its crystal symmetry does not allow it to be a ferroelectric material. Hence, the electrical properties have revived the considerable research interest on these materials, not only for academic interest, but also for technological applications. There are a few reports on temperature dependent dielectric behavior of these materials. However, the exact cause of dielectric as well as electrical conductivity is yet to be established. Hence, Al (very good conducting material) substituted barium hexaferrite (BaFe12-xAlxO19, x = 0.0-4.0) has been prepared by following the modified sol-gel method to understand the ac and DC electrical properties of these materials. The crystal structure and parameters have been studied by employing the XRD and FTIR techniques. There are two transition temperatures, which have been observed in the temperature dependent ac dielectric and DC resistivity measurement. The response of dielectric behaviors to temperature is similar to that of the ferroelectric material; however, the dielectric polarization is due to the polaron hopping, which is evident from the DC resistivity analysis. Hence, the present observations lead to understand the electrical properties of barium hexaferrite. The frequency dependent dielectric dispersion can be understood by the modified Debye model. More interestingly, the dielectric constant decreases and DC resistivity increases with the increase in the Al concentration, which has the correlation between bond length modifications in the crystal due to substitution.

  12. Influence of fuel ratios on auto combustion synthesis of barium ferrite ...

    Indian Academy of Sciences (India)

    Unknown

    Influence of fuel ratios on auto combustion synthesis of barium ferrite nano particles. D BAHADUR*, S RAJAKUMAR and ANKIT KUMAR. Department of Metallurgical Engineering and Materials Science, Indian Institute of Technology,. Mumbai 400 076 e-mail: dhirenb@iitb.ac.in. Abstract. Single-domain barium ferrite nano ...

  13. New efficient catalyst for ammonia synthesis: barium-promoted cobalt on carbon

    DEFF Research Database (Denmark)

    Hagen, Stefan; Barfod, Rasmus; Fehrmann, Rasmus

    2002-01-01

    Barium-promoted cobalt catalysts supported on carbon exhibit higher ammonia activities at synthesis temperatures than the commercial, multipromoted iron catalyst and also a lower ammonia......Barium-promoted cobalt catalysts supported on carbon exhibit higher ammonia activities at synthesis temperatures than the commercial, multipromoted iron catalyst and also a lower ammonia...

  14. Investigation on the effects of milling atmosphere on synthesis of barium ferrite/magnetite nanocomposite

    NARCIS (Netherlands)

    Molaei, M.J.; Ataie, A.; Raygan, S.; Picken, S.J.

    2011-01-01

    In this research, barium ferrite /magnetite nanocomposites synthesized via a mechano-chemical route. Graphite was used in order to reduce hematite content of barium ferrite to magnetite to produce a magnetic nanocomposite. The effects of processing conditions on the powder characteristics were

  15. Acute respiratory failure caused by aspiration of high density barium: A case report

    International Nuclear Information System (INIS)

    Park, Ki Soon; Jung, Eun A; Yang, Ik; Lee, Yul; Chung, Soo Young

    1994-01-01

    Accidental aspiration of barium contrast medium during the upper gastrointestinal study can occur in patients with swallowing disorder, especially in the elderly patients. We experienced a case of respiratory failure followed by death within a few hours in 85 year-old patient after barium aspiration

  16. Complete sulphate removal from neutralised acidic mine drainage with barium carbonate

    CSIR Research Space (South Africa)

    Swanepoel, H

    2012-03-01

    Full Text Available -barium-calcium) Desalination process which uses barium salts to further reduce the sulphate concentration to acceptable levels with the added advantage that sulphate removal can be controlled due to the low solubility of BaSO4. This paper reports on the results...

  17. Barium strontium titanate powders prepared by spray pyrolysis

    International Nuclear Information System (INIS)

    Brankovic, G.; Brankovic, Z.; Goes, M.S.; Paiva-Santos, C.O.; Cilense, M.; Varela, J.A.; Longo, E.

    2005-01-01

    Ultasonic spray pyrolysis (SP) has been investigated for the production of the barium strontium titanate (BST) powders from the polymeric precursors. The processing parameters, such as flux of aerosol and temperature profile inside the furnace, were optimized to obtain single phase BST. The powders were characterized by the methods of X-ray diffraction analysis, SEM, EDS and TEM. The obtained powders were submicronic, consisting of spherical, polycrystalline particles, with internal nanocrystalline structure. Crystallite size of 10 nm, calculated using Rietveld refinement, is in a good agreement with results of HRTEM

  18. Macroscopic polarization and thermoluminescence of barium niobate - sodium niobate

    International Nuclear Information System (INIS)

    Gorban', I.S.; Gumenyuk, A.F.; Omel'yanenko, V.A.

    1989-01-01

    Thermoluminescence (TL) of initial and thermally treated purposely undoped crystals of barium niobate - sodium has been studied within 85-400 K. The TL intensity is found to depend on the temperature to which the sample has been heated. A conclusion is drawn that nonstationarity of the TL properties is due to slowly occuring processes of compensation of pyrocharge, which depend on the temperatural prehistory of the sample. A mechanism of the traps transformation in a strong pyrofield of high-impedance crystals is discussed

  19. Radium and barium in the Amazon River system

    International Nuclear Information System (INIS)

    Moore, W.S.; Edmond, J.M.

    1984-01-01

    Data for 226 Ra and 228 Ra in the Amazon River system show that the activity of each radium isotope is strongly correlated with barium concentrations. Two trends are apparent, one for rivers which drain shield areas and another for all other rivers. These data suggest that there has been extensive fractionation of U, Th, and Ba during weathering in the Amazon basin. The 226 Ra data fit a flux model for the major ions indicating that 226 Ra behaves conservatively along the main channel of the Amazon River

  20. Regularities of radium coprecipitation with barium sulfate from salt solutions

    International Nuclear Information System (INIS)

    Kudryavskij, Yu.P.; Rakhimova, O.V.

    2007-01-01

    Coprecipitation of radium with barium sulfate from highly concentrated NaCl solutions is studied, including the effects of the initial solution composition, alkaline reagent (CaO, NaOH), supporting electrolyte (NaCl) concentration, and pH. The process is promoted by high NaCl concentration in the initial solution, which is due to structural transformation and change in the sorption activity of the BaSO 4 precipitate in salt solutions. The results obtained were applied to recovery of radium from process solutions during the development and introduction of improved procedure for disinfection and decontamination of waste yielded by chlorination of loparite concentrates [ru

  1. Rhenium corrosion in chloride melts

    International Nuclear Information System (INIS)

    Stepanov, A.D.; Shkol'nikov, S.N.; Vetyukov, M.M.

    1989-01-01

    The results investigating rhenium corrosion in chloride melts containing sodium, potassium and chromium ions by a gravimetry potentials in argon atmosphere in a sealing quarth cell are described. Rhenium corrosion is shown to be rather considerable in melts containing CrCl 2 . The value of corrosion rate depending on temperature is determined

  2. Elicitation threshold of cobalt chloride

    DEFF Research Database (Denmark)

    Fischer, Louise A; Johansen, Jeanne D; Voelund, Aage

    2016-01-01

    : On the basis of five included studies, the ED10 values of aqueous cobalt chloride ranged between 0.0663 and 1.95 µg cobalt/cm(2), corresponding to 30.8-259 ppm. CONCLUSIONS: Our analysis provides an overview of the doses of cobalt that are required to elicit allergic cobalt contactdermatitis in sensitized...

  3. Evidence against barium in the mushroom Trogia venenata as a cause of sudden unexpected deaths in Yunnan, China.

    Science.gov (United States)

    Zhang, Ying; Li, Yanchun; Wu, Gang; Feng, Bang; Yoell, Shanze; Yu, Zefen; Zhang, Keqin; Xu, Jianping

    2012-12-01

    This study examined barium concentrations in the mushroom Trogia venenata, the leading culprit for sudden unexpected deaths in Yunnan, southwest China. We found that barium concentrations in T. venenata from Yunnan were low and comparable to other foods, inconsistent with barium concentrations in this mushroom as a significant contributor to these deaths.

  4. Prospective comparison of double contrast barium enema plus flexible sigmoidoscopy v colonoscopy in rectal bleeding: barium enema v colonoscopy in rectal bleeding.

    OpenAIRE

    Irvine, E J; O'Connor, J; Frost, R A; Shorvon, P; Somers, S; Stevenson, G W; Hunt, R H

    1988-01-01

    Rectal bleeding often heralds serious colonic disease. The literature suggests that colonoscopy is superior to barium enema plus sigmoidoscopy, although no good comparative studies exist. Seventy one patients with overt rectal bleeding had prospectively flexible sigmoidoscopy, double contrast barium enema and colonoscopy completed independently. Against the gold standard, the sensitivity and specificity of colonoscopy were 0.69 and 0.78 respectively for a spectrum of colonic lesions, while fo...

  5. Evaluation of gastrointestinal tract transit times using barium-impregnated polyethylene spheres and barium sulfate suspension in a domestic pigeon (Columba livia) model.

    Science.gov (United States)

    Bloch, Rebecca A; Cronin, Kimberly; Hoover, John P; Pechman, Robert D; Payton, Mark E

    2010-03-01

    Barium impregnated polyethylene spheres (BIPS) are used in small animal medicine as an alternative to barium sulfate for radiographic studies of the gastrointestinal tract. To determine the usefulness of BIPS as an alternative to barium suspension in measuring gastrointestinal (GI) transit time for avian species, ventrodorsal radiographs were used to follow the passage of BIPS and 30% barium sulfate suspension through the GI tracts of domestic pigeons (Columba livia). Gastrointestinal transit times of thirty 1.5-mm BIPS administered in moistened gelatin capsules and 30% barium sulfate suspension gavaged into the crop were compared in 6 pigeons. Although the barium suspension passed out of the GI tract of all pigeons within 24 hours, the 1.5-mm BIPS remained in the ventriculus for 368.0 +/- 176.8 hours and did not clear the GI tract for 424.0 +/- 204.6 hours. Although the times for passage of BIPS and 30% barium sulfate suspension from the crop into the ventriculus were not significantly different (P = .14), the times for passage of BIPS from the ventriculus into the large intestine-cloaca and for clearance from the GI tract of the pigeons were significantly longer (P barium sulfate suspension. From the results of this study, we conclude that BIPS are not useful for radiographically evaluating GI transit times in pigeons and are unlikely to be useful in other avian species that have a muscular ventriculus. BIPS may or may not be useful for evaluating GI transit times in species that lack a muscular ventriculus.

  6. Atomization of magnesium, strontium, barium and lead nitrates on surface of graphite atomizers

    International Nuclear Information System (INIS)

    Nagdaev, V.K.; Pupyshev, A.A.

    1982-01-01

    Modelling of the processes on graphite surface using differential-thermal analysis and graphite core with identification of decomposition products of magnesium, strontium, barium and lead nitrates by X-ray analysis has shown that carbon promotes the formation of strontium, barium and lead carbonates. The obtained temperatures of strontium and barium carbonate decomposition to oxides agree satisfactorily with calculation ones. Magnesium nitrate does not react with carbon. Formation of strontium and barium carbonates results in considerable slowing down of the process of gaseous oxide dissociation. Lead carbonate is unstable and rapidly decomposes to oxide with subsequent reduction to free metal. Formation of magnesium, strontium and barium free atoms is connected with appearance of gaseous oxides in analytical zone. Oxide and free metal lead are present on graphite surface simultaneously

  7. Barium sulfate suspension as a negative oral contrast agent for MR imaging

    International Nuclear Information System (INIS)

    Li, K.C.P.; Tart, R.P.; Fitzsimmons, J.R.; Storm, B.; Mao, J.

    1989-01-01

    Proton spectroscopy with linewidth measurements and MR imaging were performed on various commercially available barium sulfate suspensions as well as inorganic sulfates and barium salts. Approximately 500 mL of 20%, 40%, 60%, and 70% wt/wt single-contrast oral barium sulfate suspensions were administered to four normal volunteers, and MR imaging was performed with both a 1.5-T and a 0.15-T MR imager. As much as 80% of the small bowel and the entire colon were well visualized with the 60% or 70% wt/wt single-contrast barium sulfate suspensions. The authors conclude that barium sulfate suspensions are useful as oral MR contrast agents

  8. Formation of barium strontium titanate powder by solid state reaction using different calcination temperatures

    International Nuclear Information System (INIS)

    Teoh Wah Tzu; Ahmad Fauzi Mohd Noor; Zainal Arifin Ahmad

    2002-01-01

    The unique electrical properties of large permittivity in Barium Strontium Titanate have been widely used to make capacitors; it can be produced by solid state reaction. In this study, the mixture of Barium Carbonate, Strontium Carbonate and Titanium Dioxide was calcined at 500 degree C, 1000 degree C, 1100 degree C , 1150 degree C, 1200 degree C, 1250 degree C and 1300 degree C. The results of the phases change in each stage were investigated via X ay Diffraction. The results show that the formation of Barium Strontium Titanate started at 1100 degree C with the presence of other phases. The mixture is fully reacted to form Barium Strontium Titanate at 1150 degree C. Only Barium Strontium Titanate was formed as the calcination temperature was set higher. (Author)

  9. Characterization of barium titanate powder doped with sodium and potassium ions by using Rietveld refining

    International Nuclear Information System (INIS)

    Andrade, M.C.; Assis, J.T.; Pereira, F.R.

    2009-01-01

    A solid-reaction synthesis of doped barium titanate was done by employing barium carbonates, sodium, potassium and titanium oxides with classic procedures. Rietveld refining of X ray diffraction data of perovskite samples with tetragonal symmetry was applying and show good agreement. Besides, the treatment performed from 600 deg C produces nanocrystals of barium titanate with average size of 33 nm. The presence of endothermic peaks related to BaTiO 3 formation at relatively low temperatures was determined by thermal analysis. A pseudo-Voigt Thompson-Cox-Hastings function was used to fit the standard samples of barium titanate. The Rietveld method has showed be efficient to detect the influences of temperature and doping on barium titanate microstructures. (author)

  10. Photometric Calibration of the Barium Cloud Image in a Space Active Experiment: Determining the Release Efficiency

    International Nuclear Information System (INIS)

    Xie Liang-Hai; Li Lei; Wang Jing-Dong; Tao Ran; Cheng Bing-Jun; Zhang Yi-Teng

    2014-01-01

    The barium release experiment is an effective method to explore the near-earth environment and to study all kinds of space physics processes. The first space barium release experiment in China was successfully carried out by a sounding rocket on April 5, 2013. This work is devoted to calculating the release efficiency of the barium release by analyzing the optical image observed during the experiment. First, we present a method to calibrate the images grey value of barium cloud with the reference stars to obtain the radiant fluxes at different moments. Then the release efficiency is obtained by a curve fitting with the theoretical evolution model of barium cloud. The calculated result is basically consistent with the test value on ground

  11. Anion and cation diffusion in barium titanate and strontium titanate; Anionen- und Kationendiffusion in Barium- und Strontiumtitanat

    Energy Technology Data Exchange (ETDEWEB)

    Kessel, Markus Franz

    2012-12-19

    Perovskite oxides show various interesting properties providing several technical applications. In many cases the defect chemistry is the key to understand and influence the material's properties. In this work the defect chemistry of barium titanate and strontium titanate is analysed by anion and cation diffusion experiments and subsequent time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reoxidation equation for barium titanate used in multi-layer ceramic capacitors (MLCCs) is found out by a combination of different isotope exchange experiments and the analysis of the resulting tracer diffusion profiles. It is shown that the incorporation of oxygen from water vapour is faster by orders of magnitude than from molecular oxygen. Chemical analysis shows the samples contain various dopants leading to a complex defect chemistry. Dysprosium is the most important dopant, acting partially as a donor and partially as an acceptor in this effectively acceptor-doped material. TEM and EELS analysis show the inhomogeneous distribution of Dy in a core-shell microstructure. The oxygen partial pressure and temperature dependence of the oxygen tracer diffusion coefficients is analysed and explained by the complex defect chemistry of Dy-doped barium titanate. Additional fast diffusion profiles are attributed to fast diffusion along grain boundaries. In addition to the barium titanate ceramics from an important technical application, oxygen diffusion in cubic, nominally undoped BaTiO{sub 3} single crystals has been studied by means of {sup 18}O{sub 2}/{sup 16}O{sub 2} isotope exchange annealing and subsequent determination of the isotope profiles in the solid by ToF-SIMS. It is shown that a correct description of the diffusion profiles requires the analysis of the diffusion through the surface space-charge into the material's bulk. Surface exchange coefficients, space-charge potentials and bulk diffusion coefficients are analysed as a function of oxygen partial

  12. Surface Chloride Levels in Colorado Structural Concrete

    Science.gov (United States)

    2018-01-01

    This project focused on the chloride-induced corrosion of reinforcing steel in structural concrete. The primary goal of this project is to analyze the surface chloride concentration level of the concrete bridge decks throughout Colorado. The study in...

  13. Pharmacokinetics of vinyl chloride in the rat

    International Nuclear Information System (INIS)

    Bolt, H.M.; Laib, R.J.; Kappus, H.; Buchter, A.

    1977-01-01

    When rats are exposed to [ 14 C]vinyl chloride in a closed system, the vinyl chloride present in the atmosphere equilibrates with the animals' organism within 15 min. The course of equilibration could be determined using rats which had been given 6-nitro-1,2,3-benzothiadiazole. This compound completely blocks metabolism of vinyl chloride. The enzymes responsible for metabolism of vinyl chloride are saturated at an atmospheric concentration of vinyl chloride of 250 ppm. Pharmacokinetic analysis shows that no significant cumulation of vinyl chloride or its major metabolites is to be expected on repeated administration of vinyl chlorides. This may be consistent with the theory that a reactive, shortly living metabolite which occurs in low concentration only, may be responsible for the toxic effects of vinyl chloride

  14. 21 CFR 184.1193 - Calcium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Calcium chloride. 184.1193 Section 184.1193 Food... Specific Substances Affirmed as GRAS § 184.1193 Calcium chloride. (a) Calcium chloride (CaCl2·2H2O, CAS Reg. No. 10035-04-8) or anhydrous calcium chloride (CaCl2, CAS Reg. No. 10043-52-4) may be commercially...

  15. Microbial reductive dehalogenation of vinyl chloride

    Science.gov (United States)

    Spormann, Alfred M [Stanford, CA; Muller, Jochen A [Baltimore, MD; Rosner, Bettina M [Berlin, DE; Von Abendroth, Gregory [Nannhein, DE; Meshulam-Simon, Galit [Los Altos, CA; McCarty, Perry L [Stanford, CA

    2011-11-22

    Compositions and methods are provided that relate to the bioremediation of chlorinated ethenes, particularly the bioremediation of vinyl chloride by Dehalococcoides-like organisms. An isolated strain of bacteria, Dehalococcoides sp. strain VS, that metabolizes vinyl chloride is provided; the genetic sequence of the enzyme responsible for vinyl chloride dehalogenation; methods of assessing the capability of endogenous organisms at an environmental site to metabolize vinyl chloride; and a method of using the strains of the invention for bioremediation.

  16. Synthesis of barium titanate crystalline nanoparticles using hydrothermal microwave method; Obtencao de nanoparticulas cristalinas de titanato de bario usando metodo hidrotermal assistido por microondas

    Energy Technology Data Exchange (ETDEWEB)

    Souza, A.E.; Silva, R.A.; Teixeira, S.R. [Universidade Estadual Paulista (DFQB/FCT/UNESP), Presidente Prudente, SP (Brazil). Dept. de Fisica, Quimica e Biologia. Lab. de Compositos e Ceramicas Funcionais; Moreira, M.L. [Universidade Federal de Sao Carlos (LiEC/UFSCAR), SP (Brazil). Lab. Interdisciplinar de Eletroquimica e Ceramica; Volanti, D.P.; Longo, E. [Universidade Estadual Paulista (LiEC/UNESP), Araraquara, SP (Brazil). Lab. Interdisciplinar de Eletroquimica e Ceramica

    2009-07-01

    The hydrothermal microwave method (HTMW) was used in the synthesis of barium titanate (BaTiO{sub 3}) nanoparticles. The solution was prepared in deionized water by using titanium (IV) isopropoxide (C{sub 12}H{sub 28}O{sub 4}Ti), barium chloride (BaCl{sub 2}.2H{sub 2}O) and potassium hydroxide (KOH). Afterwards it was heated in an adapted conventional microwave oven. The system is composed of a temperature controller with thermocouple, a hermetic camera of reaction made of teflon, a manometer and a safety valve. The solution was heated to 140 deg C, at a 140 deg C/min heating rate, and maintained at this temperature for 40 minutes. The obtained ceramic powder was characterized by using X-ray diffraction (XRD) and field emission scanning electron microscopy (FE-SEM). The XRD data confirms the formation of a high crystalline ceramic material with perovskite structure. The FE-SEM images reveal morphologies with dimensions varying from 27 to 54 nm. (author)

  17. 21 CFR 173.255 - Methylene chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Methylene chloride. 173.255 Section 173.255 Food... Solvents, Lubricants, Release Agents and Related Substances § 173.255 Methylene chloride. Methylene chloride may be present in food under the following conditions: (a) In spice oleoresins as a residue from...

  18. 21 CFR 182.8252 - Choline chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Choline chloride. 182.8252 Section 182.8252 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR... chloride. (a) Product. Choline chloride. (b) Conditions of use. This substance is generally recognized as...

  19. 21 CFR 184.1446 - Manganese chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Manganese chloride. 184.1446 Section 184.1446 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR... Specific Substances Affirmed as GRAS § 184.1446 Manganese chloride. (a) Manganese chloride (MnCl2·4H2O, CAS...

  20. 21 CFR 582.5985 - Zinc chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Zinc chloride. 582.5985 Section 582.5985 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS... 1 § 582.5985 Zinc chloride. (a) Product. Zinc chloride. (b) Conditions of use. This substance is...

  1. 21 CFR 582.3845 - Stannous chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Stannous chloride. 582.3845 Section 582.3845 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL....3845 Stannous chloride. (a) Product. Stannous chloride. (b) Tolerance. This substance is generally...

  2. 21 CFR 582.6193 - Calcium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Calcium chloride. 582.6193 Section 582.6193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance is generally...

  3. 21 CFR 582.5446 - Manganese chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Manganese chloride. 582.5446 Section 582.5446 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5446 Manganese chloride. (a) Product. Manganese chloride. (b) Conditions of use. This...

  4. 21 CFR 182.8985 - Zinc chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Zinc chloride. 182.8985 Section 182.8985 Food and... CONSUMPTION (CONTINUED) SUBSTANCES GENERALLY RECOGNIZED AS SAFE Nutrients § 182.8985 Zinc chloride. (a) Product. Zinc chloride. (b) Conditions of use. This substance is generally recognized as safe when used in...

  5. 21 CFR 172.180 - Stannous chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Stannous chloride. 172.180 Section 172.180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN... Preservatives § 172.180 Stannous chloride. The food additive stannous chloride may be safely used for color...

  6. 49 CFR 173.322 - Ethyl chloride.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Ethyl chloride. 173.322 Section 173.322 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.322 Ethyl chloride. Ethyl chloride must be...

  7. 21 CFR 582.5252 - Choline chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Choline chloride. 582.5252 Section 582.5252 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5252 Choline chloride. (a) Product. Choline chloride. (b) Conditions of use. This...

  8. 21 CFR 582.5622 - Potassium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Potassium chloride. 582.5622 Section 582.5622 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5622 Potassium chloride. (a) Product. Potassium chloride. (b) Conditions of use. This...

  9. 21 CFR 582.1193 - Calcium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Calcium chloride. 582.1193 Section 582.1193 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Additives § 582.1193 Calcium chloride. (a) Product. Calcium chloride. (b) Conditions of use. This substance...

  10. 7 CFR 58.434 - Calcium chloride.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Calcium chloride. 58.434 Section 58.434 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... Material § 58.434 Calcium chloride. Calcium chloride, when used, shall meet the requirements of the Food...

  11. 21 CFR 173.400 - Dimethyldialkylammonium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Dimethyldialkylammonium chloride. 173.400 Section... HUMAN CONSUMPTION Specific Usage Additives § 173.400 Dimethyldialkylammonium chloride. Dimethyldialkylammonium chloride may be safely used in food in accordance with the following prescribed conditions: (a...

  12. Materials Synthesis Of Barium Hexa ferrite Used Local Natural Resources

    International Nuclear Information System (INIS)

    Ridwan; Sulungbudi, Grace Tj.; Mujamilah

    2003-01-01

    The magnetic materials of barium hexa ferrites, Ba O.6Fe 2 O 3 successfully synthesized by powder metallurgy method used local natural resources from materials waste of steel fabrication (HSM, CRM), waste of polymer fabrication (LK) as well as iron sands (PBA). These waste as well as iron sands were the main resources of iron oxide, Fe 2 O 3 . The barium oxide used in this experiments are from BaCO 3 product of Merck, and BaCO 4 which is commercially available in the market as barite. Phase identification by x-ray diffraction technique show the synthesized magnetic materials are agreed with the available commercial product, (SUMI). The energy product maximum (BH) max measured by vibrating sample magnetometer (VSM) for the samples used HSM-, CRM- and BaCO 3 as basic materials are 1.141 MGOe and 1.136 MGOe while SUMI is 1.142 MGOe. However for the samples made from LK-, PBA- used of BaCO 3 or CRM- with barite, the energy product maximum (BH) max are relatively lower than commercial product

  13. Green Synthesis of Barium Sulfate Particles Using Plant Extracts

    Directory of Open Access Journals (Sweden)

    Chen Long

    2016-01-01

    Full Text Available The biological molecules in the extracts of four fruits or vegetables: kiwifruit, oranges, tomato and carrot, were used as templates to synthesize barium sulfate (BaSO4 particles. The products were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and X-ray power diffractometry. The results showed that, leaf-shaped barite BaSO4 crystals with toothed edge were obtained with kiwifruit extracts; thorn spherical barium sulfate crystals with diameter of 2-4 micrometers were produced with tomato extracts; rod-like or quasi-spherical BaSO4 crystals with size of several hundred nanometers to several micrometers were gained with orange extracts; while quasi-spherical BaSO4 nano-crystals were obtained with carrot extracts. The formation mechanism of BaSO4 is also discussed, showing that the proteins, carbohydrates, vitamins and organic acids in above four kinds of fruits or vegetables may provide nucleation sites, controlling the growth of BaSO4 crystals with different morphologies.

  14. Study of barium bismuth titanate prepared by mechanochemical synthesis

    Directory of Open Access Journals (Sweden)

    Lazarević Z.Ž.

    2009-01-01

    Full Text Available Barium-bismuth titanate, BaBi4Ti4O15 (BBT, a member of Aurivillius bismuth-based layer-structure perovskites, was prepared from stoichiometric amounts of barium titanate and bismuth titanate obtained via mechanochemical synthesis. Mechanochemical synthesis was performed in air atmosphere in a planetary ball mill. The reaction mechanism of BaBi4Ti4O15 and the preparation and characteristics of BBT ceramic powders were studied using XRD, Raman spectroscopy, particle analysis and SEM. The Bi-layered perovskite structure of BaBi4Ti4O15 ceramic forms at 1100 °C for 4 h without a pre-calcination step. The microstructure of BaBi4Ti4O15 exhibits plate-like grains typical for the Bi-layered structured material and spherical and polygonal grains. The Ba2+ addition leads to changes in the microstructure development, particularly in the change of the average grain size.

  15. Structural and optical study of tellurite-barium glasses

    Science.gov (United States)

    Grelowska, I.; Reben, M.; Burtan, B.; Sitarz, M.; Cisowski, J.; Yousef, El Sayed; Knapik, A.; Dudek, M.

    2016-12-01

    The goal of this work was to determine the effect of barium oxide on the structural, thermal and optical properties of the TeO2-BaO-Na2O (TBN) and TeO2-BaO-WO3 (TBW) glass systems. Raman spectra allow relating the glass structure and vibration properties (i.e. vibrational frequencies and Raman intensities) with the glass composition. Raman spectra show the presence of TeO4 and TeO3+1/TeO3 units that conform with the glass matrix. Differential thermal analysis DTA, XRD measurements have been considered in term of BaO addition. The spectral dependence of ellipsometric angles of the tellurite-barium glass has been studied. The optical measurements were conducted on Woollam M2000 spectroscopic ellipsometer in spectral range of 190-1700 nm. The reflectance and transmittance measurements have been done on spectrophotometer Perkin Elmer, Lambda 900 in the range of 200-2500 nm (UV-VIS-NIR). From the transmittance spectrum, the energy gap was determined.

  16. Barium zirconate-titanate/barium calcium-titanate ceramics via sol-gel process: novel high-energy-density capacitors

    International Nuclear Information System (INIS)

    Puli, Venkata Sreenivas; Kumar, Ashok; Scott, J F; Katiyar, Ram S; Chrisey, Douglas B; Tomozawa, M

    2011-01-01

    Lead-free barium zirconate-titanate/barium calcium-titanate, [(BaZr 0.2 Ti 0.80 )O 3 ] 1-x -[(Ba 0.70 Ca 0.30 )TiO 3 ] x (x = 0.10, 0.15, 0.20) (BZT-BCT) ceramics with high dielectric constant, low dielectric loss and moderate electric breakdown field were prepared by the sol-gel synthesis technique. X-ray diffraction patterns revealed tetragonal crystal structure and this was further confirmed by Raman spectra. Well-behaved ferroelectric hysteresis loops and moderate polarizations (spontaneous polarization, P s ∼ 3-6 μC cm -2 ) were obtained in these BZT-BCT ceramics. Frequency-dependent dielectric spectra confirmed that ferroelectric diffuse phase transition (DPT) exists near room temperature. Scanning electron microscope images revealed monolithic grain growth in samples sintered at 1280 deg. C. 1000/ε versus (T) plots revealed ferroelectric DPT behaviour with estimated γ values of ∼1.52, 1.51 and 1.88, respectively, for the studied BZT-BCT compositions. All three compositions showed packing-limited breakdown fields of ∼47-73 kV cm -1 with an energy density of 0.05-0.6 J cm -3 for thick ceramics (>1 mm). Therefore these compositions might be useful in Y5V-type capacitor applications.

  17. Barium zirconate-titanate/barium calcium-titanate ceramics via sol-gel process: novel high-energy-density capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Puli, Venkata Sreenivas; Kumar, Ashok; Scott, J F; Katiyar, Ram S [SPECLAB, Department of Physics, University of Puerto Rico, San Juan, PR 00936 (Puerto Rico); Chrisey, Douglas B; Tomozawa, M, E-mail: rkatiyar@uprrp.edu [Department of Materials Science and Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180-3590 (United States)

    2011-10-05

    Lead-free barium zirconate-titanate/barium calcium-titanate, [(BaZr{sub 0.2}Ti{sub 0.80})O{sub 3}]{sub 1-x}-[(Ba{sub 0.70}Ca{sub 0.30})TiO{sub 3}]{sub x} (x = 0.10, 0.15, 0.20) (BZT-BCT) ceramics with high dielectric constant, low dielectric loss and moderate electric breakdown field were prepared by the sol-gel synthesis technique. X-ray diffraction patterns revealed tetragonal crystal structure and this was further confirmed by Raman spectra. Well-behaved ferroelectric hysteresis loops and moderate polarizations (spontaneous polarization, P{sub s} {approx} 3-6 {mu}C cm{sup -2}) were obtained in these BZT-BCT ceramics. Frequency-dependent dielectric spectra confirmed that ferroelectric diffuse phase transition (DPT) exists near room temperature. Scanning electron microscope images revealed monolithic grain growth in samples sintered at 1280 deg. C. 1000/{epsilon} versus (T) plots revealed ferroelectric DPT behaviour with estimated {gamma} values of {approx}1.52, 1.51 and 1.88, respectively, for the studied BZT-BCT compositions. All three compositions showed packing-limited breakdown fields of {approx}47-73 kV cm{sup -1} with an energy density of 0.05-0.6 J cm{sup -3} for thick ceramics (>1 mm). Therefore these compositions might be useful in Y5V-type capacitor applications.

  18. Barium in produced water: Is it a toxicological hazard to the marine environment?

    International Nuclear Information System (INIS)

    Neff, J.M.

    1993-01-01

    Produced water is a complex aqueous mixture of organic and inorganic chemicals that often is generated in large volumes as a by-product of production of oil and gas. Produced water from offshore oil production platforms sometimes is treated to remove particulate oil and then discharged to the ocean. Barium often is the most abundant inorganic chemical, other than the dominant sea salts, in produced water. Some concern has been expressed that the large amounts of barium discharged to the ocean in produced water may have adverse effects on marine biological communities. The ecological risks associated with discharge to the ocean in produced water may have adverse effects on marine biological communities. The ecological risks associated with discharge to the ocean of barium in produced water were evaluated. Concentrations of barium in produced water from different sources range from less than 1.0 to about 2,000 mg/L, and are inversely correlated with concentrations of sulfate. Concentrations of barium in the ocean usually are in the range of 10 to 20 μg/L; the ocean is undersaturated with respect to barite (BaSO 4 ). During mixing and dilution of a produced water plume in the ocean, barium reacts with the abundant sulfate in seawater and precipitates as barite. Barite is completely nontoxic to marine organisms. Because of the high concentration of sulfate in the ocean, ionic barium can not reach concentrations high enough to be toxic to marine organisms

  19. Preparation and properties of yttria doped tetragonal zirconia polycrystal/Sr-doped barium hexaferrite ceramic composites

    International Nuclear Information System (INIS)

    Wang, Shanshan; Zhang, Chao; Guo, Ruisong; Liu, Lan; Yang, Yuexia; Li, Kehang

    2015-01-01

    Highlights: • The 3Y-TZP/Sr-doped barium ferrite composites were prepared. • The saturation magnetization was improved by 15% with Sr-doping. • The dispersion coefficient p could reflect the microscopic lattice variation. • The composite with x = 0.5 had the maximum fracture toughness of 8.3 MPa m 1/2 . - Abstract: The effects of substitution of Ba 2+ by Sr 2+ on the magnetic property of barium ferrite and addition barium ferrite secondary phase to the 3 mol% yttria-doped tetragonal zirconia polycrystal (3Y-TZP) matrix on the mechanical property of composites were investigated. The Sr-doped barium ferrite (Ba 1−x Sr x Fe 12 O 19 , x = 0, 0.25, 0.50 and 0.75) was synthesized by solid-state reaction in advance. Then 3Y-TZP/20 wt% Sr-doped barium ferrite composites were prepared by means of conventional ceramic method. It was found that a moderate amount of Sr added to barium ferrite could boost the saturation magnetization by 15% compared with the composites without Sr-doping. Besides, the composite with x = 0.50 possessed the best mechanical properties, such as 11.5 GPa for Vickers hardness and 8.3 MPa m 1/2 for fracture toughness, respectively. It was demonstrated that magnetic and mechanical properties of the composites could be harmonized by the incorporation of barium ferrite secondary phase

  20. Salt, chloride, bleach, and innate host defense

    Science.gov (United States)

    Wang, Guoshun; Nauseef, William M.

    2015-01-01

    Salt provides 2 life-essential elements: sodium and chlorine. Chloride, the ionic form of chlorine, derived exclusively from dietary absorption and constituting the most abundant anion in the human body, plays critical roles in many vital physiologic functions, from fluid retention and secretion to osmotic maintenance and pH balance. However, an often overlooked role of chloride is its function in innate host defense against infection. Chloride serves as a substrate for the generation of the potent microbicide chlorine bleach by stimulated neutrophils and also contributes to regulation of ionic homeostasis for optimal antimicrobial activity within phagosomes. An inadequate supply of chloride to phagocytes and their phagosomes, such as in CF disease and other chloride channel disorders, severely compromises host defense against infection. We provide an overview of the roles that chloride plays in normal innate immunity, highlighting specific links between defective chloride channel function and failures in host defense. PMID:26048979

  1. Salt, chloride, bleach, and innate host defense.

    Science.gov (United States)

    Wang, Guoshun; Nauseef, William M

    2015-08-01

    Salt provides 2 life-essential elements: sodium and chlorine. Chloride, the ionic form of chlorine, derived exclusively from dietary absorption and constituting the most abundant anion in the human body, plays critical roles in many vital physiologic functions, from fluid retention and secretion to osmotic maintenance and pH balance. However, an often overlooked role of chloride is its function in innate host defense against infection. Chloride serves as a substrate for the generation of the potent microbicide chlorine bleach by stimulated neutrophils and also contributes to regulation of ionic homeostasis for optimal antimicrobial activity within phagosomes. An inadequate supply of chloride to phagocytes and their phagosomes, such as in CF disease and other chloride channel disorders, severely compromises host defense against infection. We provide an overview of the roles that chloride plays in normal innate immunity, highlighting specific links between defective chloride channel function and failures in host defense. © Society for Leukocyte Biology.

  2. Removal of chloride from MSWI fly ash.

    Science.gov (United States)

    Chen, Wei-Sheng; Chang, Fang-Chih; Shen, Yun-Hwei; Tsai, Min-Shing; Ko, Chun-Han

    2012-10-30

    The high levels of alkali chloride and soluble metal salts present in MSWI fly ash is worth noting for their impact on the environment. In addition, the recycling or reuse of fly ash has become an issue because of limited landfill space. The chloride content in fly ash limits its application as basis for construction materials. Water-soluble chlorides such as potassium chloride (KCl), sodium chloride (NaCl), and calcium chloride hydrate (CaCl(2) · 2H(2)O) in fly ash are easily washed away. However, calcium chloride hydroxide (Ca(OH)Cl) might not be easy to leach away at room temperature. The roasting and washing-flushing processes were applied to remove chloride content in this study. Additionally, air and CO(2) were introduced into the washing process to neutralize the hazardous nature of chlorides. In comparison with the water flushing process, the roasting process is more efficient in reducing the process of solid-liquid separation and drying for the reuse of Cl-removed fly ash particles. In several roasting experiments, the removal of chloride content from fly ash at 1050°C for 3h showed the best results (83% chloride removal efficiency). At a solid to liquid ratio of 1:10 the water-flushing process can almost totally remove water-soluble chloride (97% chloride removal efficiency). Analyses of mineralogical change also prove the efficiency of the fly ash roasting and washing mechanisms for chloride removal. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. In vitro experiments for the development of a high density (HD) barium sulfate contrast medium

    International Nuclear Information System (INIS)

    Klein, J.

    1986-01-01

    In vitro experiments with the high-density (HD) barium meal Falibaryt HD are described. Several charges of BaSO 4 were tested together with certain additives influencing dispersion, stability of the suspension, flowability, surface tension etc. Particle size spectra were measured by the manufacturer, VEB Fahlberg-List. With a simple PVC test plate containing several grooves simulating small details (areae gastricae) the diagnostic capabilities of the HD contrast medium were evaluated in an in vitro test. The developed barium meal Falibaryt HD is in its physical and chemical parameters comparable with Prontobario-HD, one of the best HD barium meals. (author)

  4. The effect of barium temperature on esophageal and castric motility in dogs: a fluoroscopic study

    International Nuclear Information System (INIS)

    Eville, P.; Ackerman, N.

    1984-01-01

    The influence of barium temperature on canine esophageal transit time and gastric motility were studied fluoroscopically. Micropulverized barium sulfate (30% wt/vol) at 35°F, 70°F, and 100°F was given orally to each of five dogs with a minimum of two hours between each temperature. Esophageal transit times ranged from 4 to 9.67 seconds, and gastric contractions average four per minute. Barium temperature had no significant effect on either esophageal transit time or gastric motility

  5. Small bowel volvulus in children. Its appearance on the barium enema examination

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, M.J.; Shackelford, G.D.; McAlister, W.H.

    1980-01-01

    Two children with small bowel volvulus diagnosed on barium enema examination are reported. In one patient the volvulus was associated with malrotation and in the other patient there was a post-operative peritoneal adhesion. In both cases the diagnosis was based on beaking of the head of the barium column at the site of volvulus. Radiographic demonstration of a beak sign in the small bowel on barium enema examination should suggest a diagnosis of small bowel volvulus, and indicates the need for immediate surgery.

  6. A Comparative Study on Magnetostructural Properties of Barium Hexaferrite Powders Prepared by Polyethylene Glycol

    Directory of Open Access Journals (Sweden)

    Zehra Durmus

    2014-01-01

    Full Text Available Nanocrystalline particles of barium hexaferrite were synthesized by a sol-gel combustion route using nitrate-citrate gels prepared from metal nitrates and citric acid solutions with Fe/Ba molar ratio 12. The present paper aims to study the effect of addition of polyethylene glycol (PEG solutions with different molecular weights (MW: 400, 2000, and 10.000 g/mol on magnetostructural properties of barium hexaferrite. The formation of the barium hexaferrite was inspected using X-ray diffraction (XRD analysis, Fourier transform infrared (FT-IR analysis, thermogravimetric (TGA analysis, scanning electron microscopy (SEM analysis and vibrating sample magnetometer (VSM analysis for magnetic measurements.

  7. The ground states of iron(III) porphines: role of entropy-enthalpy compensation, Fermi correlation, dispersion, and zero-point energies.

    Science.gov (United States)

    Kepp, Kasper P

    2011-10-01

    Porphyrins are much studied due to their biochemical relevance and many applications. The density functional TPSSh has previously accurately described the energy of close-lying electronic states of transition metal systems such as porphyrins. However, a recent study questioned this conclusion based on calculations of five iron(III) porphines. Here, we compute the geometries of 80 different electronic configurations and the free energies of the most stable configurations with the functionals TPSSh, TPSS, and B3LYP. Zero-point energies and entropy favor high-spin by ~4kJ/mol and 0-10kJ/mol, respectively. When these effects are included, and all electronic configurations are evaluated, TPSSh correctly predicts the spin of all the four difficult phenylporphine cases and is within the lower bound of uncertainty of any known theoretical method for the fifth, iron(III) chloroporphine. Dispersion computed with DFT-D3 favors low-spin by 3-53kJ/mol (TPSSh) or 4-15kJ/mol (B3LYP) due to the attractive r(-6) term and the shorter distances in low-spin. The very large and diverse corrections from TPSS and TPSSh seem less consistent with the similarity of the systems than when calculated from B3LYP. If the functional-specific corrections are used, B3LYP and TPSSh are of equal accuracy, and TPSS is much worse, whereas if the physically reasonable B3LYP-computed dispersion effect is used for all functionals, TPSSh is accurate for all systems. B3LYP is significantly more accurate when dispersion is added, confirming previous results. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Investigation of the interaction of iron(III) complexes with dAMP by ESI-MS, MALDI-MS and potentiometric titration: insights into synthetic nuclease behavior.

    Science.gov (United States)

    Fernandes, Christiane; Oliveira Moreira, Rafaela; Lube, Leonardo M; Horn, Adolfo; Szpoganicz, Bruno; Sherrod, Stacy; Russell, David H

    2010-06-07

    We report herein the characterization by electrospray ionization (ESI) mass spectrometry (MS), matrix assisted laser desorption ionization (MALDI-MS) and potentiometric titration of three iron(III) compounds: [Fe(III)(HPClNOL)Cl2]·NO3 (1), [Cl(HPClNOL)Fe(III)-(μ-O)-Fe(III)(HPClNOL)Cl]·Cl2·H2O (2) and [(SO4)(HPClNOL)Fe(III)-(μ-O)-Fe(III)(HPClNOL)(SO4)]·6H2O (3), where HPClNOL= 1-(bis-pyridin-2-ylmethyl-amino)-3-chloropropan-2-ol). Despite the fact that the compounds have distinct structures in solid state and non-buffered solution, all compounds present similar ESI and MALDI mass spectra in a buffered medium (pH 7.0). At this pH, the species [(PClNOL)Fe(III)-(μ-O)-Fe(III)(PClNOL)](2+) (m/z 354) was observed for all the compounds under investigation. Potentiometric titration confirms a similar behavior for all compounds, indicating that the dihydroxo form [(OH)(HPClNOL)Fe(III)-(μ-O)-Fe(III)(HPClNOL)(OH)](2+) is the major species at pH 7.0, for all the compounds. The products of the interaction between compounds (1), (2) and (3) and dAMP (2'-deoxyadenosine-5'-monophosphate) in a buffered medium (pH 7.0) were identified by MALDI-MS/MS. The fragmentation data obtained by MS/MS allow one to identify the nature of the interaction between the iron(III) compounds and dAMP, revealing the direct interaction between the iron center and phosphate groups.

  9. Barium depletion study on impregnated cathodes and lifetime prediction

    International Nuclear Information System (INIS)

    Roquais, J.M.; Poret, F.; Doze, R. le; Ricaud, J.L.; Monterrin, A.; Steinbrunn, A.

    2003-01-01

    In the thermionic cathodes used in cathode ray-tubes (CRTs), barium is the key element for the electronic emission. In the case of the dispenser cathodes made of a porous tungsten pellet impregnated with Ba, Ca aluminates, the evaporation of Ba determines the cathode lifetime with respect to emission performance in the CRT. The Ba evaporation results in progressive depletion of the impregnating material inside the pellet. In the present work, the Ba depletion with time has been extensively characterized over a large range of cathode temperature. Calculations using the depletion data allowed modeling of the depletion as a function of key parameters. The link between measured depletion and emission in tubes has been established, from which an end-of-life criterion was deduced. Taking modeling into account, predicting accelerated life-tests were performed using high-density maximum emission current (MIK)

  10. Barium titanate nanocomposite capacitor FY09 year end report.

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, Tyler E.; DiAntonio, Christopher Brian; Yang, Pin; Chavez, Tom P.; Winter, Michael R.; Monson, Todd C.; Roesler, Alexander William; Fellows, Benjamin D.

    2009-11-01

    This late start RTBF project started the development of barium titanate (BTO)/glass nanocomposite capacitors for future and emerging energy storage applications. The long term goal of this work is to decrease the size, weight, and cost of ceramic capacitors while increasing their reliability. Ceramic-based nanocomposites have the potential to yield materials with enhanced permittivity, breakdown strength (BDS), and reduced strain, which can increase the energy density of capacitors and increase their shot life. Composites of BTO in glass will limit grain growth during device fabrication (preserving nanoparticle grain size and enhanced properties), resulting in devices with improved density, permittivity, BDS, and shot life. BTO will eliminate the issues associated with Pb toxicity and volatility as well as the variation in energy storage vs. temperature of PZT based devices. During the last six months of FY09 this work focused on developing syntheses for BTO nanoparticles and firing profiles for sintering BTO/glass composite capacitors.

  11. Quantitative radio-chemical separation of calcium, strontium and barium

    International Nuclear Information System (INIS)

    Dupuis, M.C.; Dupuis, M.; Le Nagard, M.; Michot, H.

    1965-01-01

    A method for separation of Ca 45 , Sr 89 and Ba 140 has been developed for the radiochemical determination of these isotopes in a solution of fission with a large concentration of mineral salts. After removal of most fission products by solvent extraction (TTA-MIBK) at different pH, the alkaline earths are extracted from the aqueous phase at pH 9. After recovery with diluted hydrochloric acid, the three elements are adsorbed on cationic resin Dowex 50 and eluted sequentially with ammonium α - Hydroxy iso-butyrate using gradient concentration and pH. Ca 45 and Sr 89 are measured by β - counting and Ba 140 by γ spectrometry. The chemical yield approximates 80 per cent for calcium, and 70 per cent for strontium and barium. The decontamination factor is 10 5 for most fission products. Four separations can be performed in twenty hours. (authors) [fr

  12. Microscopic theory of the phonon frequencies in BCC barium

    International Nuclear Information System (INIS)

    Oli, B.A.

    1988-09-01

    The phonon dispersion frequencies are calculated from first principles for bbc barium using a resonance pseudopotential model which incorporates the effect of s-d hybridization. It was also possible using this scheme to account for the anomalous feature of the Ba dispersion curve observed experimentally in the (ξ,0,0) direction where the frequencies of the transverse branch are higher than the frequencies of the longitudinal branch. The frequencies obtained were also used to calculate the phonon density of states by the linear-analytic tetrahedra method of zone integration. The results of these calculations are qualitatively in good agreement with experimental data, and provide further support to the interpretation of the anomalous behaviour in the (ξ,0,0) direction as arising from s-d hybridization. (author). 27 refs, 4 figs, 3 tabs

  13. X-ray and Moessbauer investigations of isotropic barium ferrites

    International Nuclear Information System (INIS)

    Kirichok, P.P.; Pashchenko, V.A.; Dem'yaniv, T.O.; Ryabova, G.N.; Lisovskij, A.M.

    1984-01-01

    Using the methods of X-ray and γ-resonance spectroscopy the crystal chemical and magnetic structure of isotropic barium hexaferrites is studied. compacting pressure the lattice parameter c of ferrite of the BaOx5.7Fe 2 O 3 is decreased and the diffraction line width on its X-ray p attern is increased. Due to increasing the isoststical compacting pressure quadrupole splitting of the γ-resonance absorption spectrum of 57 Fe nuclei in tetrahedral positions 4f 1 and in positions 2a decreases. The sintering temperature growth leads to increasing the lattice parameter c and diffraction line widths and decreasing the effeutive field values and isomeric s hifts on 57 Fe nuclei. Isostatical compacting pressure does not affect the electron configuration of iron ions

  14. Structural and magnetic properties of barium-gadolinium hexaferrites

    Science.gov (United States)

    Litsardakis, G.; Manolakis, I.; Serletis, C.; Efthimiadis, K. G.

    A series of Gd-substituted M-type barium hexaferrites has been prepared by the ceramic route, according to the formula (Ba 1-xGd x)O·5.25Fe 2O 3 ( x=0-0.30). XRD analysis revealed that all the samples present primarily an M-type structure. Samples x=0 and x=0.05 are single-phase. Hematite (Fe 2O 3) and GdFeO 3 were detected in the remaining samples. Coercivity ( Hc) shows remarkably high values, ˜293 kA/m for x=0.20 and 0.30 with a maximum of 322 kA/m for x=0.25. Specific saturation magnetization ( σsat) of the samples presents a small increase up to x=0.10. The microstructure examination indicates that Gd may act as a grain growth inhibitor.

  15. Bronchography in dogs. Comparative study with two barium sulphate solutions

    International Nuclear Information System (INIS)

    Thibaut, J.; Gallardo, P.; Vargas, L.; Deppe, R.; Born, R.

    1998-01-01

    Two solutions of barium sulphate, 60 and 30% w/v, were compared with the ''overflow'' Bronchographic method. Two groups of eight healthy adult does of both sexes, weighing 7 to 18 kg were used for the study. The dogs were anaesthetised with thiopentone sodium 2% (20 mg/kg iv). After intubation, each dog received contrast medium by a catheter connected to a syringe, in a 9 mi dose. Two series of two x-rays plates were taken in left lateral recumbent, 3 and 6 min after administering the contrast medium and in ventrodorsal projection, 30 sec. later. The x-ray plates obtained were analysed and compared intra and inter group considering the advance speed of the contrast medium, the radiographic density and outlines. Adverse reactions were controlled

  16. Assessment of patient exposure for barium enema examinations

    International Nuclear Information System (INIS)

    Bednarek, D.R.; Rudin, S.; Wong, R.

    1983-01-01

    Methods are described for the assessment of patient exposure during clinical fluoroscopic procedures. Values of the roentgen-area-product (RAP) and their distribution throughout the examination are presented for both single-contrast and double-contrast barium enema studies. The double-contrast procedure was measured to give 50% more radiation to the patient than the single-contrast procedure when the same size optical aperture is used between the intensifier and TV pick-up tube. However, it was possible to decrease the fluoroscopic RAP value by over a factor of two for the double-contrast procedure without an adverse clinical effect by increasing the area of the aperture diaphragm

  17. Synthesis and characterization of barium fluoride substituted zinc tellurite glasses

    Science.gov (United States)

    Aishwarya, K.; Vinitha, G.; Varma, G. Sreevidya; Asokan, S.; Manikandan, N.

    2017-12-01

    Glasses in the TeO2-ZnO-BaF2 system were prepared by standard melt quenching technique and were characterized for their thermal, optical and structural properties. Samples were found to show good thermal stability with values ranging above 100 °C for all the compositions. Optical bandgap and refractive index values were calculated from linear optical measurements using UV-Vis spectroscopy. Infrared spectra showed the presence of hydroxyl groups in the glasses indicating that the effect of fluorine was negligible in removing the hydroxyl impurities for the experimental conditions and compositions used. Raman measurements showed the modification occurring in the glass network due to addition of barium fluoride in terms of increase in the formation of non-bridging oxygen atoms compared to strong Te-O-Te linkages in the glass matrix.

  18. Analysis of barium hydroxide and calcium hydroxide slurry carbonation reactors

    International Nuclear Information System (INIS)

    Patch, K.D.; Hart, R.P.; Schumacher, W.A.

    1980-05-01

    The removal of CO 2 from air was investigated by using a continuous-agitated-slurry carbonation reactor containing either barium hydroxide [Ba(OH) 2 ] or calcium hydroxide [Ca(OH) 2 ]. Such a process would be applied to scrub 14 CO 2 from stack gases at nuclear-fuel reprocessing plants. Decontamination factors were characterized for reactor conditions which could alter hydrodynamic behavior. An attempt was made to characterize reactor performance with models assuming both plug flow and various degrees of backmixing in the gas phase. The Ba(OH) 2 slurry enabled increased conversion, but apparently the process was controlled under some conditions by phenomena differing from those observed for carbonation by Ca(OH) 2 . Overall reaction mechanisms are postulated

  19. Microwave absorption properties of barium titanate/epoxide resin composites

    International Nuclear Information System (INIS)

    Chen Xiaodong; Wang Guiqin; Duan Yuping; Liu Shunhua

    2007-01-01

    Nano-barium titanate (BT) was prepared by a sol-gel method. The prepared powders were characterized by x-ray powder diffraction and transmission electron microscopy. The complex relative dielectric permittivity (ε = ε' - jε-prime) and magnetic permeability (μ = μ' - jμ-prime) of the BT powders were measured in the frequency range 8 ∼ 18 GHz. The BT/epoxide resin (EP) composite with different volume contents was investigated. The effects of thickness on the BT/EP composite were studied. It was found that an optimum thickness and contents of the absorber can yield the maximum reflection loss which could be obtained over a broad frequency region in the X and Ku bands. Our results indicate that BT could be a promising microwave absorption material

  20. Structural and functional characterization of barium zirconium titanate / epoxy composites

    Directory of Open Access Journals (Sweden)

    Filiberto González Garcia

    2011-12-01

    Full Text Available The dielectric behavior of composite materials (barium zirconium titanate / epoxy system was analyzed as a function of ceramic concentration. Structure and morphologic behavior of the composites was investigated by X-ray Diffraction (XRD, Fourier transformed infrared spectroscopy (FT-IR, Raman spectroscopy, field emission scanning electron microscopy (FE-SEM and transmission electron microscopy (TEM analyses. Composites were prepared by mixing the components and pouring them into suitable moulds. It was demonstrated that the amount of inorganic phase affects the morphology of the presented composites. XRD revealed the presence of a single phase while Raman scattering confirmed structural transitions as a function of ceramic concentration. Changes in the ceramic concentration affected Raman modes and the distribution of particles along into in epoxy matrix. Dielectric permittivity and dielectric losses were influenced by filler concentration.

  1. Effect of Nb on barium titanate prepared from citrate solutions

    Directory of Open Access Journals (Sweden)

    Stojanović Biljana D.

    2002-01-01

    Full Text Available The influence of the addition of dopants on the microstructure development and electrical properties of BaTiO3 doped with 0.2, 0.4, 0.6, 0.8 mol% of Nb and 0.01 mol% of Mn based compounds was studied. Doped barium titanate was prepared using the polymeric precursor method from citrate solutions. The powders calcined at 700°C for 4 hours were analysed by infrared (IR spectroscopy to verify the presence of carbonates, and by X-ray diffraction (XRD for phase formation. The phase composition, microstructure and dielectric properties show a strong dependence on the amount of added niobium.

  2. Stark effect in Rydberg states of helium and barium

    International Nuclear Information System (INIS)

    Lahaije, C.T.W.

    1989-01-01

    This thesis, which deals with the effect of an electric field up to moderate field strengths on atoms with two valence electrons outside closed shells, in casu helium and barium, contains chapter in which the linear Stark effect in the 1 snp 1, 3 p Rydberg states of helium (n around 40) has been studied in a CW laser-atomic beam experiment. The evolution of the angular momentum manifolds into the n-mixing regime was followed and avoided level crossings were observed. Stark manifolds were also calculated by diagonalization of the complete energy matrix in the presence of an electric field. It turned out to be necessary to include up to five n-values in the calculations already at moderate values of the field to reproduce the data within the experimental accuracy (a few MHz), especially in the regime of the avoided crossings. (author). 147 refs.; 30 figs.; 8 tabs

  3. Hydrolysis of cupric chloride in aqueous ammoniacal ammonium chloride solutions

    Directory of Open Access Journals (Sweden)

    Limpo, J. L.

    1995-06-01

    Full Text Available Cupric solubility in the CuCl2-NH4Cl-NH3-H2O system for chloride concentrations lower than 4 molal in the temperature range 25-60 °C was studied. The experimental results show that for chloride concentration between 3.0 and 1.0 molal the cupric solubility is determined by the solubility of the cupric hydroxychloride Cu(OH1.5Cl0.5. For a chloride concentration value of 4.0 molal, there are two cupric compounds, the hydroxychloride Cu(OH1.5Cl0.5 or the diammine chloride Cu(NH32Cl2, on which the solubility of Cu(II depends, according to the temperature and the value of the ratio [NH3]Total/[Cu]Total.

    Se estudia la solubilidad del Cu(II en el sistema CuCl2-NH4Cl-NH3-H2O para concentraciones de cloruro inferiores a 4 molal en el intervalo de temperaturas 25-60 °C. Los resultados experimentales muestran que, para concentraciones de cloruros comprendidas entre 3,0 y 1,0 molal, la solubilidad cúprica viene determinada por la solubilidad del hidroxicloruro cúprico, Cu(OH1.5Cl0.5. Para concentraciones de cloruro 4,0 molal, existen dos compuestos cúpricos, el hidroxicloruro, Cu(OH1.5Cl0.5 o el cloruro de diamina, Cu(NH32Cl2, de los que, de acuerdo con la temperatura y con el valor de la relación [NH3]Total/[Cu]Total depende la solubilidad del Cu(II.

  4. Primary versus secondary achalasia: New signs on barium esophagogram

    Science.gov (United States)

    Gupta, Pankaj; Debi, Uma; Sinha, Saroj Kant; Prasad, Kaushal Kishor

    2015-01-01

    Aim: To investigate new signs on barium swallow that can differentiate primary from secondary achalasia. Materials and Methods: Records of 30 patients with primary achalasia and 17 patients with secondary achalasia were reviewed. Clinical, endoscopic, and manometric data was recorded. Barium esophagograms were evaluated for peristalsis and morphology of distal esophageal segment (length, symmetry, nodularity, shouldering, filling defects, and “tram-track sign”). Results: Mean age at presentation was 39 years in primary achalasia and 49 years in secondary achalasia. The mean duration of symptoms was 3.5 years in primary achalasia and 3 months in secondary achalasia. False-negative endoscopic results were noted in the first instance in five patients. In the secondary achalasia group, five patients had distal esophageal segment morphology indistinguishable from that of primary achalasia. None of the patients with primary achalasia and 35% patients with secondary achalasia had a length of the distal segment approaching combined height of two vertebral bodies. None of the patients with secondary achalasia and 34% patients with primary achalasia had maximum caliber of esophagus approaching combined height of two vertebral bodies. Tertiary contractions were noted in 90% patients with primary achalasia and 24% patients with secondary achalasia. Tram-track sign was found in 55% patients with primary achalasia. Filling defects in the distal esophageal segment were noted in 94% patients with secondary achalasia. Conclusion: Length of distal esophageal segment, tertiary contractions, tram-track sign, and filling defects in distal esophageal segment are useful esophagographic features distinguishing primary from secondary achalasia. PMID:26288525

  5. Association between esophageal dysmotility and gastroesophaeal reflux on barium studies

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Craig [Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA 19104 (United States); Levine, Marc S. [Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA 19104 (United States)]. E-mail: marc.levine@uphs.upenn.edu; Rubesin, Stephen E. [Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA 19104 (United States); Laufer, Igor [Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA 19104 (United States); Redfern, Gina [Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA 19104 (United States); Katzka, David A. [Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, PA 19104 (United States)

    2006-07-15

    Objective: To determine whether there is an association between abnormal primary peristalsis in the esophagus and gastroesophageal reflux (GER) on barium studies. Methods: A computerized search of radiologic reports revealed 151 patients with esophageal dysmotility (characterized by intermittently decreased or absent peristalsis in the esophagus on upper gastrointestinal tract examinations) who fulfilled our study's entry criteria. These 151 patients were stratified into two groups depending on whether this dysmotility was associated with nonperistaltic contractions (NPCs): 92 patients had no NPCs (Dysmotility and No NPCs Group) and 59 had NPCs (Dysmotility and NPCs Group). An age-matched control group of 92 patients with normal motility was also generated from the radiologic reports. The reports were also reviewed for the presence and degree of GER and other complications of GER. The frequency and degree of GER were tabulated for each group, and the data were analyzed using a Pearson chi square test to determine if significant differences were present in the frequency and degree of GER or other findings among the groups. Results: The frequency of GER was significantly higher in patients with abnormal peristalsis and no NPCs than in controls (p = 0.02). When GER was stratified based on the degree of reflux, the frequency of moderate-to-marked GER was significantly higher in patients with abnormal peristalsis and no NPCs than in patients with abnormal peristalsis and NPCs (p = 0.01) or in controls (p = 0.0031). The frequency of reflux esophagitis also was significantly higher in patients with abnormal peristalsis and no NPCs than in controls (p = 0.04). Conclusion: Our findings suggest that patients with esophageal dysmotility characterized by intermittently decreased or absent peristalsis without NPCs have a significantly higher frequency and degree of GER than patients with normal motility. The presence of this specific form of esophageal dysmotility on

  6. Synthesis of Zirconium Lower Chlorides

    International Nuclear Information System (INIS)

    Gaviria, Juan P.

    2002-01-01

    This research is accurately related to the Halox concept of research reactor spent fuel element treatment.The aim of this project is to work the conditioning through selected chlorination of the element that make the spent fuel element. This research studied the physical chemistry conditions which produce formation of the lower zirconium chlorides through the reaction between metallic Zr and gaseous ZrCl 4 in a silica reactor.This work focused special attention in the analysis and confrontation of the published results among the different authors in order to reveal coincidences and contradictions.Experimental section consisted in a set of synthesis with different reaction conditions and reactor design. After reaction were analyzed the products on Zr shavings and the deposit growth on wall reactor.The products were strongly dependent of reactor design. It was observed that as the distance between Zr and wall reactor increased greater was tendency to lower chlorides formation.In reactors with small distance the reaction follows other way without formation of lower chlorides.Analysis on deposit growth on reactor showed that may be formed to a mixture of Si x Zr y intermetallics and zirconium oxides.Presence of oxygen in Zr and Zr-Si compounds on wall reactor reveals that there is an interaction between quartz and reactants.This interaction is in gaseous phase because contamination is observed in experiences where Zr was not in contact with reactor.Finally, it was made a global analysis of all experiences and a possible mechanism that interprets reaction ways is proposed

  7. Qualitative analysis of barium particles coated in small intestinal mucosa of rabbit by using scanning electron microscopy

    International Nuclear Information System (INIS)

    Lee, Yong Suk; Ha, Hyun Kwon; Lee, Yang Seob; Kim, Jae Kyun; Yoon, Seong Eon; Kim, Jung Hoon; Chung, Dong Jin; Auh, Yong Ho

    1998-01-01

    To qualitatively analysed barium coating status in the intestinal mucosa, we used scanning electron microscopy to observe barium particles coated in the small intestinal mucosa of rabbit, and we attempted to assess the relationship between electron microscopic findings and radiographic densities. Six different combination of barium and methylcellulose suspensions were infused into the resected small intestines of 15 rabbits. Barium powders were mixed with water to make 40% and 70% w/v barium solutions, and also mixed with 0.5% methylcellulose solutions were used as a double contrast agent. After the infusion of barium suspensions, a mammography unit was used to obtain radiographs of the small intestine, and their optical densities were measured by a densitometer. Thereafter, photographs of barium-coated small intestinal mucosa were obtained using a scanning electron microscope (x 8,000), and the number of barium particles in the unit area were measured. To compare the relationship between the electron microscopic findings and optical densities, statistical analysis using Spearman correlation was performed. This study shows that by using scanning electron microscopy, barium particles coated on the small intestinal mucosa can be qualitatively analysed. It also shows that the number of small barium particles measured by scanning electron microscopy is related to optical densities. (author). 14 refs., 2 figs

  8. Melting in trivalent metal chlorides

    International Nuclear Information System (INIS)

    Saboungi, M.L.; Price, D.L.; Scamehorn, C.; Tosi, M.P.

    1990-11-01

    We report a neutron diffraction study of the liquid structure of YCl 3 and combine the structural data with macroscopic melting and transport data to contrast the behaviour of this molten salt with those of SrCl 2 , ZnCl 2 and AlCl 3 as prototypes of different melting mechanisms for ionic materials. A novel melting mechanism for trivalent metal chlorides, leading to a loose disordered network of edge-sharing octahedral units in the liquid phase, is thereby established. The various melting behaviours are related to bonding character with the help of Pettifor's phenomenological chemical scale. (author). 25 refs, 4 figs, 3 tabs

  9. Comparison of barium swallow and ultrasound in diagnosis of gastro-oesophageal reflux in children.

    Science.gov (United States)

    Naik, D R; Bolia, A; Moore, D J

    1985-01-01

    Fifty one infants and older children with suspected gastro-oesophageal reflux entered a study comparing the diagnostic accuracy of a standard barium swallow examination with that of ultrasound scanning. All children were examined by both techniques. In 40 cases there was unequivocal agreement between the examinations. Of the remaining patients, four had definite reflux by ultrasonic criteria but showed no evidence of reflux on barium swallow examination, four had positive findings on ultrasound but showed only minimal reflux on barium swallow, and one showed minimal reflux on ultrasound but had a negative barium meal result. In two children the ultrasound study was inconclusive. Ultrasound has an important role in the diagnosis and follow up of patients under the age of 5 years with gastro-oesophageal reflux. Images FIG 1 FIG 2 PMID:3924317

  10. Corrosion-electrochemical behaviour and mechanical properties ofaluminium alloy-321, alloyed by barium

    International Nuclear Information System (INIS)

    Ganiev, I.; Mukhiddinov, G.N.; Kargapolova, T.V.; Mirsaidov, U.

    1995-01-01

    The purpose of present work is studying of influence of barium additionson electrochemical corrosion of casting aluminium-copper alloy Al-321,containing as base alloying components copper, chromium, manganese, titanium,zirconium, cadmium

  11. Recovery and separation of rare-earth elements, barium, and strontium from bastnasite with sulfuric acid

    International Nuclear Information System (INIS)

    Eisele, J.A.; Bauer, D.J.

    1974-01-01

    A bench-scale investigation was made of a concentrated H 2 SO 4 reaction for recovering and separating rare earth elements, barium, and strontium from a bastnaesite ore and byproduct. Barium and strontium were dissolved in the concentrated acid and precipitated as a mixed product by water dilution. Separation of strontium from barium was effected by reaction with Na 2 CO 3 solution, followed by a dilute acid leach of the SrCO 3 formed. After removing the barium and strontium from bastnaesite ore, the rare-earth elements were roasted to water-soluble sulfates. The rare earth sulfate solution was subsequently processed by solvent extraction to produce rare-earth oxides low in lead and magnesium. (U.S.)

  12. Severe acute cholangitis after endoscopic sphincterotomy induced by barium examination: A case report.

    Science.gov (United States)

    Zhang, Zhen-Hai; Wu, Ya-Guang; Qin, Cheng-Kun; Su, Zhong-Xue; Xu, Jian; Xian, Guo-Zhe; Wu, Shuo-Dong

    2012-10-21

    Endoscopic sphincterotomy (EST) is considered as a possible etiological factor for severe cholangitis. We herein report a case of severe cholangitis after endoscopic sphincterotomy induced by barium examination. An adult male patient presented with epigastric pain was diagnosed as having choledocholithiasis by ultrasonography. EST was performed and the stone was completely cleaned. Barium examination was done 3 d after EST and severe cholangitis appeared 4 h later. The patient was recovered after treated with tienam for 4 d. Barium examination may induce severe cholangitis in patients after EST, although rare, barium examination should be chosen cautiously. Cautions should be also used when EST is performed in patients younger than 50 years to avoid the damage to the sphincter of Oddi.

  13. An experimental study on sterilized barium sulfate (BaSO4) for vertebroplasty

    International Nuclear Information System (INIS)

    Chen Long; Ni Caifang; Ding Yi; Wang Yijin

    2005-01-01

    Objective: To search the proper sterilization method of barium for vertebroplasty. Methods: Perfusion agents were classified into two groups with ratio of powder/liquid(g/ml) as 3:2, and the percentage of BsSO 4 in powder was 20%. The barium powder in one group was sterilized by dry-heat and by ethylene oxide in the other. The barium powder of each group was germicultured and the polymerization time, CT value, strength and stiffness were measured respectively including 6 samples. Two independent-samples t text was used for analysis. Results: The germiculture in each group was negative. The difference in polmerization time and CT value of each group were not significant (P>0.05), while the strength and stiffness were significantly different (P<0.05). Conclusions: Sterilized effects of two groups were satisfied but the dry-heat barium sulfate is superior, more suitable for vertebroplasty. (authors)

  14. Sensitivity of single contrast barium enema with regard to colorectal disease as diagnosed by colonoscopy

    International Nuclear Information System (INIS)

    Kaude, J.V.; Harty, R.F.

    1982-01-01

    The results of single contrast barium enema were retrospectively correlated with colonoscopically diagnosed colorectal disease in 54 patients (75 lesions). Altogether 66 lesions (88%) were correctly diagnosed. The sensitivity of barium enema for polyps was 81% (26/32). There were three perceptive errors and three polyps 5 mm or less in size were not demonstrated by barium enema. Twenty-nine cases of inflammatory disorders were all correctly diagnosed. One of 12 malignancies was missed by perceptive error. In two cases with vascular malformations the barium enema was normal. 4/9 (44%) of missed lesions were perceptive errors and could have been probably avoided by a second independent reading of films. (orig.)

  15. How changes in a radiologist's technique can reduce patient dose in barium enema studies

    International Nuclear Information System (INIS)

    Corbett, R.H.

    2001-01-01

    Changes in a radiologist's technique, especially utilising digital technology, can lead to substantial dose savings in barium enema examinations. Data will be provided showing a 20% saving with only minimal change in technique. (author)

  16. Calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid

    International Nuclear Information System (INIS)

    Kurbanov, A.R.; Sharipov, D.Sh.

    1993-01-01

    Present article is devoted to calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid. The calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid was carried out in order to determine the thermal effects of reactions. The results of interaction of Ba(OH) 4 ·8H 2 O with 5, 10, and 20% solution of hydrofluoric acid were considered.

  17. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough

    OpenAIRE

    Nin, Carlos Shuler; Marchiori, Edson; Irion, Klaus Loureiro; Paludo, Artur de Oliveira; Alves, Giordano Rafael Tronco; Hochhegger, Daniela Reis; Hochhegger, Bruno

    2013-01-01

    OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough.METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks) were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological...

  18. Calculations of energy levels and lifetimes of low-lying states of barium and radium

    International Nuclear Information System (INIS)

    Dzuba, V. A.; Ginges, J. S. M.

    2006-01-01

    We use the configuration-interaction method and many-body perturbation theory to perform accurate calculations of energy levels, transition amplitudes, and lifetimes of low-lying states of barium and radium. Calculations for radium are needed for the planning of measurements of parity- and time-invariance-violating effects which are strongly enhanced in this atom. Calculations for barium are used to control the accuracy of the calculations

  19. Role of Barium Swallow in Diagnosing Clinically Significant Anastomotic Leak following Esophagectomy

    Directory of Open Access Journals (Sweden)

    Simon Roh

    2016-04-01

    Full Text Available Background: Barium swallow is performed following esophagectomy to evaluate the anastomosis for detection of leaks and to assess the emptying of the gastric conduit. The aim of this study was to evaluate the reliability of the barium swallow study in diagnosing anastomotic leaks following esophagectomy. Methods: Patients who underwent esophagectomy from January 2000 to December 2013 at our institution were investigated. Barium swallow was routinely done between days 5–7 to detect a leak. These results were compared to clinically determined leaks (defined by neck wound infection requiring jejunal feeds and or parenteral nutrition during the postoperative period. The sensitivity and specificity of barium swallow in diagnosing clinically significant anastomotic leaks was determined. Results: A total of 395 esophagectomies were performed (mean age, 62.2 years. The indications for the esophagectomy were as follows: malignancy (n=320, high-grade dysplasia (n=14, perforation (n=27, benign stricture (n=7, achalasia (n=16, and other (n=11. A variety of techniques were used including transhiatal (n=351, McKeown (n=35, and Ivor Lewis (n=9 esophagectomies. Operative mortality was 2.8% (n=11. Three hundred and sixty-eight patients (93% underwent barium swallow study after esophagectomy. Clinically significant anastomotic leak was identified in 36 patients (9.8%. Barium swallow was able to detect only 13/36 clinically significant leaks. The sensitivity of the swallow in diagnosing a leak was 36% and specificity was 97%. The positive and negative predictive values of barium swallow study in detecting leaks were 59% and 93%, respectively. Conclusion: Barium swallow is an insensitive but specific test for detecting leaks at the cervical anastomotic site after esophagectomy.

  20. Studies on phase evolution and electrical conductivity of barium doped gadolinium aluminate

    International Nuclear Information System (INIS)

    Sinha, Amit; Sharma, B.P.; Gopalan, P.

    2012-01-01

    Highlights: ► Barium doped GdAlO 3 compositions were prepared from citrate gel derived powders. ► The solid solubility of barium in GdAlO 3 was less than 4 mol%. ► The un-dissolved barium precipitated in the form of BaAl 2 O 4 phase. ► The conductivity of Ba-doped GdAlO 3 increased with increasing amounts of Ba. ► In Gd 1−x Ba x AlO 3−δ system, specimen with x = 0.02 exhibited maximum conductivity. - Abstract: The phase evolution and electrical conductivity of barium doped GdAlO 3 samples have been investigated. The Ba- doped compositions of GdAlO 3 were prepared through citrate gel process. Analysis of the phases was carried out using X-ray diffraction (XRD). The morphology of the calcined powders was studied by scanning electron microscopy. The electrical conductivity of Gd 1−x Ba x AlO 3−δ (x = 0–0.04) was measured using ac impedance spectroscopy as a function of temperature ranging from 300 to 1000 °C under air. The solid solubility of barium in GdAlO 3 was found to be less than 4 mol%. The undissolved barium precipitated in the form of BaAl 2 O 4 phase. The barium doped GdAlO 3 powders obtained after calcination at 1000 °C was found to be porous agglomerate composed of nanocrystalline grains. The total electrical conductivity of Ba-doped GdAlO 3 increased with increasing amounts of barium up to 2 mol% doping.

  1. Barium isotopes in Allende meteorite - Evidence against an extinct superheavy element

    Science.gov (United States)

    Lewis, R. S.; Anders, E.; Shimamura, T.; Lugmair, G. W.

    1983-01-01

    Carbon and chromite fractions from the Allende meteorite that contain isotopically anomalous xenon-131 to xenon-136 (carbonaceous chondrite fission or CCF xenon) at up to 5 x 10 to the 11th atoms per gram show no detectable isotopic anomalies in barium-130 to barium-138. This rules out the possibility that the CCF xenon was formed by in situ fission of an extinct superheavy element. Apparently the CCF xenon and its carbonaceous carrier are relics from stellar nucleosynthesis.

  2. Generation of sub-100-fs Stokes pulses upon SRS in a barium nitrate crystal

    International Nuclear Information System (INIS)

    Konyashchenko, Aleksandr V; Losev, Leonid L; Tenyakov, S Yu

    2010-01-01

    72-fs pulses are generated at the first Stokes component frequency upon stimulated Raman scattering in a barium nitrate crystal for the radiation of the Ti 3+ :Al 2 O 3 laser with the pulse duration of 50 fs. The energy efficiency of conversion is 20%. The barium nitrate crystal was optically pumped by two consecutive orthogonally polarised chirped pulses with the following time compression of the Stokes radiation pulse. (nonlinear optical phenomena)

  3. Renal abnormalities in congenital chloride diarrhea

    International Nuclear Information System (INIS)

    Al-Hamad, Nadia M.; Al-Eisa, Amal A.

    2004-01-01

    Congenital chloride diarrhea CLD is a rare autosomal recessive disorder caused by a defect in the chloride/ bicarbonate exchange in the ileum and colon. It is characterized by watery diarrhea, abdominal distension, hypochloremic hypokalemic metabolic alkalosis with high fecal content of chloride >90 mmol/l. We report 3 patients with CLD associated with various renal abnormalities including chronic renal failure secondary to renal hypoplasia, nephrocalcinosis and congenital nephrotic syndrome. (author)

  4. Tunable ferromagnetic resonance in La-Co substituted barium hexaferrites at millimeter wave frequencies

    Science.gov (United States)

    Korolev, Konstantin A.; Wu, Chuanjian; Yu, Zhong; Sun, Ke; Afsar, Mohammed N.; Harris, Vincent G.

    2018-05-01

    Transmittance measurements have been performed on La-Co substituted barium hexaferrites in millimeter waves. Broadband millimeter-wave measurements have been carried out using the free space quasi-optical spectrometer, equipped with a set of high power backward wave oscillators covering the frequency range of 30 - 120 GHz. Strong absorption zones have been observed in the millimeter-wave transmittance spectra of all La-Co substituted barium hexaferrites due to the ferromagnetic resonance. Linear shift of ferromagnetic resonance frequency as functions of La-Co substitutions have been found. Real and imaginary parts of dielectric permittivity of La-Co substituted barium hexaferrites have been calculated using the analysis of recorded high precision transmittance spectra. Frequency dependences of magnetic permeability of La-Co substituted barium hexaferrites, as well as saturation magnetization and anisotropy field have been determined based on Schlömann's theory for partially magnetized ferrites. La-Co substituted barium hexaferrites have been further investigated by DC magnetization to assess magnetic behavior and compare with millimeter wave data. Consistency of saturation magnetization determined independently by both millimeter wave absorption and DC magnetization have been found for all La-Co substituted barium hexaferrites. These materials seem to be quite promising as tunable millimeter wave absorbers, filters, circulators, based on the adjusting of their substitution parameters.

  5. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough

    Directory of Open Access Journals (Sweden)

    Carlos Shuler Nin

    2013-12-01

    Full Text Available OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough.METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons.RESULTS: The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6% of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6% of the patients, whereas the treatment was ineffective in 1 (8.4%. We observed no complications related to barium swallow, such as contrast aspiration.CONCLUSIONS: Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies.

  6. The impact of digital imaging on patient doses during barium studies

    International Nuclear Information System (INIS)

    Broadhead, D.A.; Chapple, C.-L.; Faulkner, K.

    1995-01-01

    Barium studies performed on 10 digital and four non-digital fluoroscopic systems were monitored with dose-area product meters as part of a Regional Patient Dosimetry Audit programme. The data have been collected using a computer to read and reset the dose-area product meter and also to collect patient and examination details. A comparison of dose-area product measurements from digital and non-digital fluoroscopy units on over 10 000 barium studies is presented. The data have been corrected according to patient size. The mean size corrected dose-area product for a barium meal examination was found to be 7.62 Gy cm -2 for a digital set compared with 15.45 Gy cm -2 for a non-digital set with 2462 and 1308 patients included in each measurement series, respectively. Dose-area products were also a factor of approximately two lower for barium enema, barium swallow and barium follow-through examinations performed on digital systems. (author)

  7. Experimental studies on 3D printing of barium titanate ceramics for medical applications

    Directory of Open Access Journals (Sweden)

    Schult Mark

    2016-09-01

    Full Text Available The present work deals with the 3D printing of porous barium titanate ceramics. Barium titanate is a biocompatible material with piezoelectric properties. Due to insufficient flowability of the starting material for 3D printing, the barium titanate raw material has been modified in three different ways. Firstly, barium titanate powder has been calcined. Secondly, flow additives have been added to the powder. And thirdly, flow additives have been added to the calcined powder. Finally, a polymer has been added to the three materials and specimens have been printed from these three material mixtures. The 3D printed parts were then sintered at 1320°C. The sintering leads to shrinkage which differs between 29.51–71.53% for the tested material mixtures. The porosity of the parts is beneficial for cell growth which is relevant for future medical applications. The results reported in this study demonstrate the possibility to fabricate porous piezoelectric barium titanate parts with a 3D printer that can be used for medical applications. 3D printed porous barium titanate ceramics can especially be used as scaffold for bone tissue engineering, where the bone formation can be promoted by electrical stimulation.

  8. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough.

    Science.gov (United States)

    Nin, Carlos Shuler; Marchiori, Edson; Irion, Klaus Loureiro; Paludo, Artur de Oliveira; Alves, Giordano Rafael Tronco; Hochhegger, Daniela Reis; Hochhegger, Bruno

    2013-01-01

    To assess the routine use of barium swallow study in patients with chronic cough. Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks) were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons. The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6%) of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6%) of the patients, whereas the treatment was ineffective in 1 (8.4%). We observed no complications related to barium swallow, such as contrast aspiration. Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies.

  9. Virtual colonoscopy with electron beam CT: correlation with barium enema, colonoscopy and pathology

    International Nuclear Information System (INIS)

    Hong, Hye Suk; Kim, Min Jung; Chung, Jae Joon; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1998-01-01

    To perform virtual colonoscopy using electron beam tomography(EBT) in patients in whom a colonic mass was present, and to compare the results with those obtained using barium enema, colonoscopy and gross pathologic specimens. Materials and Methods : Ten patients in whom colonic masses were diagnosed by either barium enema or colonoscopy were involved in this study. There were nine cases of adenocarcinoma and one of tubulovillous adenoma. Using EBT preoperative abdominopelvic CT scans were performed. Axial scans were then three-dimensionally reconstructed to produce virtual colonoscopic images and were compared with barium enema, colonoscopy and gross pathologic specimens. Virtual colonoscopic images of the masses were classified as either 1)polyploid, 2)sessile,3)fungating, or 4)annular constrictive. We also determined whether ulcers were present within the lesions and whether there was obstruction. Results : After virtual colonoscopy, two lesions were classified as polyploid, one as sessile, five as fungating and two as annular constrictive. Virtual colonoscopic images showed good correlation with the findings of barium enema, colonoscopy and gross pathologic specimens. Three of six ulcerative lesions were observed on colonoscopy; in seven adenocarcinomas with partial or total luminal obstruction, virtual colonoscopy visualized the colon beyond the obstructed sites. In one case, barium contrast failed to pass through the obstructed portion and in six cases, the colonoscope similarly failed. Conclusion : Virtual colonoscopies correlated well with barium enema, colonoscopy and gross pathologic specimens. They provide three dimensional images of colonic masses and are helpful for the evaluation of obstructive lesions

  10. Comparison of Calcium and Barium Microcapsules as Scaffolds in the Development of Artificial Dermal Papillae.

    Science.gov (United States)

    Liu, Yang; Lin, Changmin; Zeng, Yang; Li, Haihong; Cai, Bozhi; Huang, Keng; Yuan, Yanping; Li, Yu

    2016-01-01

    This study aimed to develop and evaluate barium and calcium microcapsules as candidates for scaffolding in artificial dermal papilla. Dermal papilla cells (DPCs) were isolated and cultured by one-step collagenase treatment. The DPC-Ba and DPC-Ca microcapsules were prepared by using a specially designed, high-voltage, electric-field droplet generator. Selected microcapsules were assessed for long-term inductive properties with xenotransplantation into Sprague-Dawley rat ears. Both barium and calcium microcapsules maintained xenogenic dermal papilla cells in an immunoisolated environment and induced the formation of hair follicle structures. Calcium microcapsules showed better biocompatibility, permeability, and cell viability in comparison with barium microcapsules. Before 18 weeks, calcium microcapsules gathered together, with no substantial immune response. After 32 weeks, some microcapsules were near inflammatory cells and wrapped with fiber. A few large hair follicles were found. Control samples showed no marked changes at the implantation site. Barium microcapsules were superior to calcium microcapsules in structural and mechanical stability. The cells encapsulated in hydrogel barium microcapsules exhibited higher short-term viability. This study established a model to culture DPCs in 3D culture conditions. Barium microcapsules may be useful in short-term transplantation study. Calcium microcapsules may provide an effective scaffold for the development of artificial dermal papilla.

  11. Barium ionization mechanisms in the CRRES G-1 and G-11b releases

    International Nuclear Information System (INIS)

    Hunton, D.E.

    1993-01-01

    The G-11b chemical release experiment form the Combined Release and Radiation Effects Satellite (CRRES) was conducted in darkness below the solar UV terminator to test the Critical Ionization Velocity (CIV) hypothesis. The Quadrupole Ion Mass Spectrometer (QIMS) aboard CRRES measured fluxes of barium ions from this darkness release that were only a factor of ten smaller than the G-1 release measurements in full sunlight. Possible mechanisms for this significant barium ionization in darkness include CIV, charge exchange with O + , collisional ionization and associative ionization. The authors have evaluated the relative contributions of the collisional mechanisms by constructing a simple model of barium ions from the darkness release seem to be consistent with recent measurements of the charge transfer cross section. A collective plasma ionization mechanism such as CIV does not seem to necessary in order to explain the large barium ion fluxes observed. However, QIMS could only detect barium ions formed several seconds after the initial detonation of the release canister. A CIV process could still have occurred very early in the expansion of the barium neutral cloud and the mass spectrometer would not have detected these ions

  12. Preparation of porous nano barium ferrite and its adsorption properties on uranium

    International Nuclear Information System (INIS)

    Xiong Guoxuan; Huang Haiqing; Zhang Zhibin

    2012-01-01

    The porous nano barium ferrite was made of Fe(NO 3 ) 3 and Ba(NO 3 ) 2 as raw materials, CTAB as surfactant by method of sol-gel and self-propagating combustion. The composition, morphology and magnetic properties of nano-rod barium ferrite were characterized by XRD, SEM and vibrating sample magnetometer. The adsorption properties of porous nano barium ferrite on uranium were studied with static adsorption and the effects of pH, adsorption temperature and oscillation time on adsorption properties were discussed. The results indicate that the average particle size of porous nano barium ferrite is 45-65 nm, the saturation magnetization and coercivity are 62.83 emu/g and 5481.0 Oe, respectively. Under the condition of the porous nano barium ferrite amount of 0.02 g, pH of 6, adsorption temperature of 25℃ and oscillation time of 30 min, the adsorption capacity of uranium on the porous nano barium ferrite reaches 921 μg/g. (authors)

  13. Method of processing chloride waste

    International Nuclear Information System (INIS)

    Tokiwai, Moriyasu; Tsunashima, Mikiyasu; Horie, Masaaki; Koyama, Masafumi; Sudo, Minoru; Kitagawa, Masatoshi; Ogasawara, Tadashi.

    1991-01-01

    In a method of applying molten salt electrolysis to chloride wastes discharged from a electrolytic refining step of a dry reprocessing step for spent fuels, and removed with transuranium elements of long half-decaying time, metals capable of alloying with alkali and alkaline earth metals under melting by electrolysis are used as a cathode material, and an electrolytic temperature is made higher than the melting point of salts in a molten salt electrolysis bath, to recover Li, Ca and Na as alloys with the cathode material in a first electrolysis step. Then, the electrolytic temperature is made higher than the melting point of the chloride salts remained in the bath after the electrolysis step described above by using the cathode material, to recover Ba, Rb, Sr and Cs of nuclear fission products also as alloys with the cathode material in a second electrolysis step. Accordingly, the amount of wastes formed can be reduced, and the wastes contain no heat generating nuclear fission elements. (T.M.)

  14. Electrochemical chloride extraction of a beam polluted by chlorides after 40 years in the sea

    OpenAIRE

    BOUTEILLER, Véronique; LAPLAUD, André; MALOULA, Aurélie; MORELLE, René Stéphane; DUCHESNE, Béatrice; MORIN, Mathieu

    2006-01-01

    A beam element, naturally polluted by chlorides after 40 years of a marine tidal exposure, has been treated by electrochemical chloride extraction. The chloride profiles, before and after treatment, show that free chlorides are extrated with an efficiency of 70 % close to the steel, 50 % in the intermediate cover and only 5 % at the concrete surface. From the electrochemical characterizations (before, after, 1, 2 and 17 months after treatment), the steel potential values can, semehow, indicat...

  15. Thermochemistry of alkali chloride - lanthanoide(III) chlorides

    International Nuclear Information System (INIS)

    Blachnik, R.; Selle, D.

    1979-01-01

    The phase diagrams of the mixtures KCl + GdCl 3 resp. DyCl 3 and of CsCl + PrCl 3 (DyCl 3 , ErCl 3 , and YbCl 3 ) were investigated by differential thermal analysis. In the mixtures of lanthanoide(III) chlorides with CsCl resp. KCl three different stoichiometries of the compounds were found, namely A 3 MCl 6 , A 2 MCl 5 , and AM 2 Cl 7 . Debyeograms of the compounds A 3 MCl 6 and AM 2 Cl 7 reveal, that in the case of the latter type all compounds with the same alkali halide have identical structure, whereas in the A 3 MCl 6 compounds three different types of X-ray patterns were observed. The stabilities of the congruently melting compounds can be estimated by comparing the melting point of the compound with the temperature of an extrapolated eutectic point. (author)

  16. DIELECTRIC AND PYROELECTRIC PROPERTIES OF THE COMPOSITES OF FERROELECTRIC CERAMIC AND POLY(VINYL CHLORIDE

    Directory of Open Access Journals (Sweden)

    M.Olszowy

    2003-01-01

    Full Text Available The dielectric and pyroelectric properties of lead zirconate titanate/poly(vinyl chloride [PZT/PVC] and barium titanate/poly(vinyl chloride [BaTiO3/ PVC] composites were studied. Flexible composites were fabricated in the thin films form (200-400 μm by hot-pressed method. Powders of PZT or BaTiO3 in the shape of ≤ 75 μm ceramics particles were dispersed in a PVC matrix, providing composites with 0-3} connectivity. Distribution of the ceramic particles in the polymer phase was examined by scanning electron microscopy. The analysis of the thermally stimulated currents (TSC have also been done. The changes of dielectric and pyroelectric data on composites with different contents of ceramics up to 40% volume were investigated. The dielectric constants were measured in the frequency range from 600 Hz to 6 MHz at room temperature. The pyroelectric coefficient for BaTiO3/PVC composite at 343 K is about 35 μC/m2K which is higher than that of β-PVDF (10 μC/m2 K.

  17. Effect of ionic strength on barium transport in porous media

    Science.gov (United States)

    Ye, Zi; Prigiobbe, Valentina

    2018-02-01

    Hydraulic fracturing (or fracking) is a well stimulation technique used to extract resources from a low permeability formation. Currently, the most common application of fracking is for the extraction of oil and gas from shale. During the operation, a large volume of brine, rich in hazardous chemicals, is produced. Spills of brine from wells or pits might negatively impact underground water resources and, in particular, one of the major concerns is the migration of radionuclides, such as radium (Ra2+), into the shallow subsurface. However, the transport behaviour of Ra2+ through a reactive porous medium under conditions typical of a brine, i.e., high salinity, is not well understood, yet. Here, a study on the transport behaviour of barium (Ba2+, congener of radium) through a porous medium containing a common mineral such as goethite (FeO(OH)) is presented. Batch and column flood tests were carried out at conditions resembling the produced brine, i.e., large values of ionic strength (I), namely, 1 to 3 mol/kg. The measurements were described with the triple layer surface complexation model coupled with the Pitzer activity coefficient method and a reactive transport model, in the case of the transport tests. The experimental results show that the adsorption of Ba2+ onto FeO(OH) increases with pH but decreases with I and it becomes negligible at the brine conditions. Moreover, even if isotherms show adsorption at large I, at the same conditions during transport, Ba2+ travels without retardation through the FeO(OH) porous medium. The triple layer model agrees very well with all batch data but it does not describe well the transport tests in all cases. In particular, the model cannot match the pH measurements at large I values. This suggests that the chemical reactions at the solid-liquid interface do not capture the mechanism of Ba2+ adsorption onto FeO(OH) at large salinity. Finally, this study suggests that barium, and potentially its congeners, namely, radium

  18. Supramolecular curcumin-barium prodrugs for formulating with ceramic particles.

    Science.gov (United States)

    Kamalasanan, Kaladhar; Anupriya; Deepa, M K; Sharma, Chandra P

    2014-10-01

    A simple and stable curcumin-ceramic combined formulation was developed with an aim to improve curcumin stability and release profile in the presence of reactive ceramic particles for potential dental and orthopedic applications. For that, curcumin was complexed with barium (Ba(2+)) to prepare curcumin-barium (BaCur) complex. Upon removal of the unbound curcumin and Ba(2+) by dialysis, a water-soluble BaCur complex was obtained. The complex was showing [M+1](+) peak at 10,000-20,000 with multiple fractionation peaks of MALDI-TOF-MS studies, showed that the complex was a supramolecular multimer. The (1)H NMR and FTIR studies revealed that, divalent Ba(2+) interacted predominantly through di-phenolic groups of curcumin to form an end-to-end complex resulted in supramolecular multimer. The overall crystallinity of the BaCur was lower than curcumin as per XRD analysis. The complexation of Ba(2+) to curcumin did not degrade curcumin as per HPLC studies. The fluorescence spectrum was blue shifted upon Ba(2+) complexation with curcumin. Monodisperse nanoparticles with size less than 200dnm was formed, out of the supramolecular complex upon dialysis, as per DLS, and upon loading into pluronic micelles the size was remaining in similar order of magnitude as per DLS and AFM studies. Stability of the curcumin was improved greater than 50% after complexation with Ba(2+) as per UV/Vis spectroscopy. Loading of the supramloecular nanoparticles into pluronic micelles had further improved the stability of curcumin to approx. 70% in water. These BaCur supramolecule nanoparticles can be considered as a new class of prodrugs with improved solubility and stability. Subsequently, ceramic nanoparticles with varying chemical composition were prepared for changing the material surface reactivity in terms of the increase in, degradability, surface pH and protein adsorption. Further, these ceramic particles were combined with curcumin prodrug formulations and optimized the curcumin release

  19. Optimization of multiroute synthesis for polyaniline-barium ferrite composites

    Energy Technology Data Exchange (ETDEWEB)

    Ben Ghzaiel, Tayssir, E-mail: tayssir.ben-ghzaiel@satie.ens-cachan.fr [Université de Tunis El Manar Faculté des Sciences de Tunis, UR11ES18 Unité de Recherche de Chimie Minérale Appliquée, 2092, Tunis (Tunisia); SATIE, ENS Cachan, CNRS, Université Paris-Saclay, 61 av du Président Wilson, F-94230, Cachan (France); Dhaoui, Wadia [Université de Tunis El Manar Faculté des Sciences de Tunis, UR11ES18 Unité de Recherche de Chimie Minérale Appliquée, 2092, Tunis (Tunisia); Pasko, Alexander; Mazaleyrat, Frédéric [SATIE, ENS Cachan, CNRS, Université Paris-Saclay, 61 av du Président Wilson, F-94230, Cachan (France)

    2016-08-15

    A comparative study of physicochemical and magnetic properties of Polyaniline-BaFe{sub 12}O{sub 19} composites prepared by Solid-Based Polymerization (SBP) and by Aqueous-Based Polymerization (ABP) is carried out. The composites obtained by the latter method underwent a grinding to study the influence of shear stress. Thus, in a systematic approach, an investigation of stirring effect was done by synthesizing these composites using aqueous-based polymerization but without mechanical stirring. Different mass ratio of BaFe{sub 12}O{sub 19} was used to explore their impact on composites properties. X-ray diffraction, FTIR, SEM, TGA, conductivity and vibrating sample magnetometer measurements were performed. Structural and morphological investigations confirmed the presence of polyaniline and barium hexaferrite phase, which were in interaction in the composites regardless the polymerization route. The powder obtained by solid-based pathway revealed distinct particles with uniform distribution for various compositions (wt. %) of BaFe{sub 12}O{sub 19} in Pani, while the composites obtained by aqueous-based polymerization presented agglomerated nanostructures. Thermogravimetric analysis exhibited an improved thermal stability for Pani-BaFe{sub 12}O{sub 19} obtained by solid-based route. The electric conductivity has displayed decreasing trend of DC conductivity with the increase of BaFe{sub 12}O{sub 19} particles in the polymer matrix. Magnetic studies showed a ferromagnetic behaviour for all composites. The saturation magnetization monotonously increased with the increasing of BaFe{sub 12}O{sub 19} amount. The magnetic properties of the powders were mainly related to the hexaferrite loading which was determined using measured magnetic data. These results revealed that magnetization saturation was dependant of volume fraction of ferrite in the composites which was significantly affected by the reaction medium and mechanical stirring. The powders obtained by solid

  20. Monte Carlo estimation for pediatric barium meal procedures

    International Nuclear Information System (INIS)

    Filipov, D.; Schelin, H.R.; Denyak, V.; Legnani, A.; Ledesma, J.A.; Paschuk, S.A.; Sauzen, J.; Yagui, A.; Hoff, G.; Khoury, H.J.

    2015-01-01

    Fluoroscopic barium meal (BM) series involve an X-ray examination of the esophagus, stomach, and duodenum, by the use of a contrast media – the barium sulfate (BaSO4). They are widely used to observe digestive functions or to diagnose abnormalities such as ulcers; tumors; inflammation of the esophagus, stomach, and duodenum; malrotations; vascular rings; and gastroesophageal reflux disease (a common ailment in children). However, this procedure uses long fluoroscopy times and multiple radiographies, resulting in high effective doses to pediatric patients, whose radiosensitivity and life expectancy are higher than in adults. Based on those data, the aims of the current study are to: determine the P K,A (kerma-area product) values, on the patient chest area, and the effective doses to 5 and 10 years old children. Thirty-seven different pediatric patients were studied and stratified into two group sizes: 5 and 10 years old. For each procedure, the following data was recorded: sex, age and upper chest thickness, from the patients; technical parameters of the procedure (kV, fluoroscopy time and number of radiographies); distances (focus-detector and focus-table) and field size on the examination table. Three pairs of LiF:Mg,Ti thermoluminescent dosimeters were positioned at the center of the child´s sternum. After that, upper chest thickness was subtracted from focus-table distance, so focus-patient distance was obtained. Using the field size on the table and applying similar triangles concepts, the field size on the patient was measured, which was multiplied by the mean kerma (from the dosimeters), so that P K,A could be determined. To estimate the effective dose, P K,A and technical parameters of the procedure (kV, total filtration, focus-detector distance and field size on the patient) were written in a Monte Carlo software simulation. The results of P K,A and effective doses were higher than studies used for comparison, which shows the importance of an

  1. Study of decomposition kinetics of volatile β-diketonates of yttrium, barium and copper in flow reactor

    International Nuclear Information System (INIS)

    Devyatykh, G.G.; Gavrishchuk, E.M.; Gibin, A.M.; Dadanov, A.Yu.; Dzyubenko, N.G.; Kaul', A.R.; Nichiporuk, R.V.; Snezhko, N.T.; Ul'yanov, A.A.

    1990-01-01

    Heterogeneous oxidative decomposition of adduct of yttrium acetylacetonate with o-phenanthroline, copper acetylacetonate and barium dipivaloylmethanate in a flow-type reactor was carried out. The basic kinetic characteristics of chemical precipitation processes of films of yttrium, copper and barium oxides, which are components of high-temperature superconductors, were obtained. The values of activation energy of precipitation process of yttrium, copper and barium oxides constituted 76±10, 108±15, 81±12 (t 600 deg C) respectively

  2. Chloride ingress in cement paste and mortar

    DEFF Research Database (Denmark)

    Jensen, Ole Mejlhede; Hansen, Per Freiesleben; Coats, Alison M.

    1999-01-01

    In this paper chloride ingress in cement paste and mortar is followed by electron probe microanalysis. The influence of several paste and exposure parameters on chloride ingress are examined (e.g., water-cement ratio, silica fume addition, exposure time, and temperature), The measurements...

  3. Chloride binding site of neurotransmitter sodium symporters

    DEFF Research Database (Denmark)

    Kantcheva, Adriana Krassimirova; Quick, Matthias; Shi, Lei

    2013-01-01

    Neurotransmitter:sodium symporters (NSSs) play a critical role in signaling by reuptake of neurotransmitters. Eukaryotic NSSs are chloride-dependent, whereas prokaryotic NSS homologs like LeuT are chloride-independent but contain an acidic residue (Glu290 in LeuT) at a site where eukaryotic NSSs...

  4. Synthesis of 14C-dehydrocorydaline chloride

    International Nuclear Information System (INIS)

    Zhang Rui; Wang Ding

    1988-01-01

    A method for synthesis of 14 C-dehydrocorydaline chloride is described. In the presence of sodium hydroxide, acetonylpalmatine is reacted with 14 C-methyl iodide in sealed glass ampoule to give 14 C-13-methylpalmatine iodide which is then converted to chloride. The radiochemical purity of 14 C-dehydrocorydaline determined by TLC is over 98% and the labelling efficiency is 54%

  5. Chronopotentiometric chloride sensing using transition time measurement

    NARCIS (Netherlands)

    Abbas, Yawar; de Graaf, D.B.; Olthuis, Wouter; van den Berg, Albert

    2013-01-01

    Detection of chloride ions is crucial to accurately access the concrete structure durability[1]. The existing electrochemical method of chloride ions detection in concrete, potentiometry[1], is not suitable for in-situ measurement due to the long term stability issue of conventional reference

  6. 29 CFR 1915.1017 - Vinyl chloride.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Vinyl chloride. 1915.1017 Section 1915.1017 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... § 1915.1017 Vinyl chloride. Note: The requirements applicable to shipyard employment under this section...

  7. 29 CFR 1926.1152 - Methylene chloride.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Methylene chloride. 1926.1152 Section 1926.1152 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... Methylene chloride. Note: The requirements applicable to construction employment under this section are...

  8. 29 CFR 1915.1052 - Methylene chloride.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Methylene chloride. 1915.1052 Section 1915.1052 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... § 1915.1052 Methylene chloride. Note: The requirements applicable to shipyard employment under this...

  9. 29 CFR 1926.1117 - Vinyl chloride.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Vinyl chloride. 1926.1117 Section 1926.1117 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... chloride. Note: The requirements applicable to construction work under this section are identical to those...

  10. Properties of silver chloride track detectors

    International Nuclear Information System (INIS)

    Dmitriev, V.D.; Kocherov, N.P.; Novikova, N.R.; Perfilov, N.A.

    1976-01-01

    The experiments on preparation of silver chloride track detectors and their properties are described. The results of X-ray structural analysis and data on sensitivity to charged particles and actinic light of silver chloride crystals, doped with several elements, are presented. (orig.) [de

  11. Dechlorinating reaction of organic chlorides

    Energy Technology Data Exchange (ETDEWEB)

    Yahata, Taneaki; Kihara, Shinji [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Ohuchi, Misao

    1996-06-01

    Dechlorination has been examined by the reaction between iron, aluminum powder or CaO and organic chlorides such as C{sub 2}HCl{sub 3} and CH{sub 2}Cl{sub 2}. Progress of the reaction was analyzed with mass spectrometer. The reaction between iron and organic chloride was rapidly occurred at the temperature between 350 and 440degC in an atmosphere of argon. Above 380degC, more than 99.5% of C{sub 2}HCl{sub 3} was decomposed within approximately 100 minutes. At 440degC, approximately 60% of C{sub 2}HCl{sub 3} was decomposed by the reaction with aluminium powder within approximately 100 minutes. At 440degC, reaction between C{sub 2}HCl{sub 3} and CaO powder were occurred rapidly in an atmosphere of argon to form CaCl{sub 2} and free carbon. Also in an atmosphere of air, nearly the same result was obtained. In this reaction, CaCl{sub 2}, CO and CO{sub 2} were formed. CH{sub 2}Cl{sub 2} was also decomposed by the reaction with iron at the temperature between 380 and 440degC. In the reaction, FeCl{sub 2}, carbon and hydrogen were formed. CH{sub 3}{sup +} and CH{sub 4} were observed during the dechlorinating reaction of CH{sub 2}Cl{sub 2}. Variation in particle size of iron powder such as 100, 150 and 250 mesh did not affect the reaction rate. (author)

  12. Properties of barium strontium titanate at millimeter wave frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Osman, Nurul [Department of Physics, Universiti Putra Malaysia (Malaysia); Free, Charles [Department of Engineering and Design, University of Sussex (United Kingdom)

    2015-04-24

    The trend towards using higher millimetre-wave frequencies for communication systems has created a need for accurate characterization of materials to be used at these frequencies. Barium Strontium Titanate (BST) is a ferroelectric material whose permittivity is known to change as a function of applied electric field and have found varieties of application in electronic and communication field. In this work, new data on the properties of BST characterize using the free space technique at frequencies between 145 GHz and 155 GHz for both thick film and bulk samples are presented. The measurement data provided useful information on effective permittivity and loss tangent for all the BST samples. Data on the material transmission, reflection properties as well as loss will also be presented. The outcome of the work shows through practical measurement, that BST has a high permittivity with moderate losses and the results also shows that BST has suitable properties to be used as RAM for high frequency application.

  13. Review on dielectric properties of rare earth doped barium titanate

    International Nuclear Information System (INIS)

    Ismail, Fatin Adila; Osman, Rozana Aina Maulat; Idris, Mohd Sobri

    2016-01-01

    Rare earth doped Barium Titanate (BaTiO_3) were studied due to high permittivity, excellent electrical properties and have wide usage in various applications. This paper reviewed on the electrical properties of RE doped BaTiO_3 (RE: Lanthanum (La), Erbium (Er), Samarium (Sm), Neodymium (Nd), Cerium (Ce)), processing method, phase transition occurred and solid solution range for complete study. Most of the RE doped BaTiO_3 downshifted the Curie temperature (T_C). Transition temperature also known as Curie temperature, T_C where the ceramics had a transition from ferroelectric to a paraelectric phase. In this review, the dielectric constant of La-doped BaTiO_3, Er-doped BaTiO_3, Sm-doped BaTiO_3, Nd-doped BaTiO_3 and Ce-doped BaTiO_3 had been proved to increase and the transition temperature or also known as T_C also lowered down to room temperature as for all the RE doped BaTiO_3 except for Er-doped BaTiO_3.

  14. Colonic diverticulosis: evaluation with double contrast barium enema

    International Nuclear Information System (INIS)

    Ko, Jae Kook; Lee, Jong Koo; Yun, Eun Joo; Moon, Hee Jung; Shin, Hyun Ja

    1997-01-01

    To evaluate the pattern of colonic diverticulosis according to age and sex, and recent trend. The authors retrospectively reviewed 120 cases of colonic diverticulosis in 1,020 patients who had undergone a double contrast barium enema examination between January 1st, 1993, and December 31st, 1995, and analyzed the frequency, size, multiplicity and anatomical site, according to age and sex. Diverticulum size was classified into one of three groups : less than 5mm, 5-10mm, over 10mm in diameter. The overall incidence of colonic diverticulosis was 120 cases among 1,020 patients(11.8%) with an incidence 5.3 times higher in males than in females. Peak incidence was in the fifth decade, with 19 cases (15.8%) among males, and after the sixth decade, with four cases(3.3%) among females. Mean age was 57.7 years. Diverticulum size of 5-10mm in diameter was predominant (2% of cases); average diameter was 5-6mm. The incidence of colonic diverticulosis was 5.1 times more frequent in the right colon (101 cases) than in the left (20 cases). The overall incidence of colonic diverticulosis has continually increased; in addition it has also recently increased slightly in left-sided colon. This is thought to be due to various factors, both congenital and acquired, including longer life with good health care, constipation, irritable bowel syndrome, stress and the tendency of eating patterns to more closely resemble those of the west

  15. Barium from a mini r-process in supernovae

    Science.gov (United States)

    Heymann, D.

    1983-01-01

    McCulloch and Wasserburg (1978) have reported nonlinear isotopic anomalies in barium for two Ca-Al-rich inclusions of the Allende carbonaceous chondrite, known as EK-1-4-1 and C-1. In an attempt to account for these anomalies, it has been proposed that Ba from an r-process of nucleosynthesis, containing Ba-135 and Ba-137, was injected into the primeval color system but was not totally homogenized. Questions arise in connection with the relations of Xe isotopes in carbonaceous chondrites. This has prompted Heymann and Dziczkaniec (1979, 1980, 1981) to study the formation of r-Xe, r-Kr, and r-Te by the mini r-process which is thought to occur in the O, Ne-rich shells of Type II supernovae. Lee et al. (1979) have studied the formation of r-Ba, r-Nd, and r-Sm by the same process. Certain differences regarding the approaches used by Lee et al. and by Heymann and Dziczkaniec make it necessary to restudy the work of Lee et al. Attention is given to the survival probabilities of nuclear species of interest, taking into accounts the elements Cs, Ba, I, and Xe.

  16. Colonic diverticulosis: evaluation with double contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jae Kook; Lee, Jong Koo; Yun, Eun Joo; Moon, Hee Jung; Shin, Hyun Ja [Korea Veterans Hospital, Seoul (Korea, Republic of)

    1997-02-01

    To evaluate the pattern of colonic diverticulosis according to age and sex, and recent trend. The authors retrospectively reviewed 120 cases of colonic diverticulosis in 1,020 patients who had undergone a double contrast barium enema examination between January 1st, 1993, and December 31st, 1995, and analyzed the frequency, size, multiplicity and anatomical site, according to age and sex. Diverticulum size was classified into one of three groups : less than 5mm, 5-10mm, over 10mm in diameter. The overall incidence of colonic diverticulosis was 120 cases among 1,020 patients(11.8%) with an incidence 5.3 times higher in males than in females. Peak incidence was in the fifth decade, with 19 cases (15.8%) among males, and after the sixth decade, with four cases(3.3%) among females. Mean age was 57.7 years. Diverticulum size of 5-10mm in diameter was predominant (2% of cases); average diameter was 5-6mm. The incidence of colonic diverticulosis was 5.1 times more frequent in the right colon (101 cases) than in the left (20 cases). The overall incidence of colonic diverticulosis has continually increased; in addition it has also recently increased slightly in left-sided colon. This is thought to be due to various factors, both congenital and acquired, including longer life with good health care, constipation, irritable bowel syndrome, stress and the tendency of eating patterns to more closely resemble those of the west.

  17. Structural and magnetic properties of barium-gadolinium hexaferrites

    Energy Technology Data Exchange (ETDEWEB)

    Litsardakis, G. [Department of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki 54124 (Greece)]. E-mail: Lits@eng.auth.gr; Manolakis, I. [Department of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki 54124 (Greece); Serletis, C. [Department of Physics, Aristotle University of Thessaloniki, Thessaloniki 54124 (Greece); Efthimiadis, K.G. [Department of Physics, Aristotle University of Thessaloniki, Thessaloniki 54124 (Greece)

    2007-03-15

    A series of Gd-substituted M-type barium hexaferrites has been prepared by the ceramic route, according to the formula (Ba{sub 1-x}Gd{sub x})O.5.25Fe{sub 2}O{sub 3} (x=0-0.30). XRD analysis revealed that all the samples present primarily an M-type structure. Samples x=0 and x=0.05 are single-phase. Hematite (Fe{sub 2}O{sub 3}) and GdFeO{sub 3} were detected in the remaining samples. Coercivity (H{sub c}) shows remarkably high values, {approx}293kA/m for x=0.20 and 0.30 with a maximum of 322kA/m for x=0.25. Specific saturation magnetization ({sigma}{sub sat}) of the samples presents a small increase up to x=0.10. The microstructure examination indicates that Gd may act as a grain growth inhibitor.

  18. Stability of cyclopentadienyl aryloxide complexes of calcium and barium

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Melanie J.; Burkey, David J.; Chmely, Stephen C. [Department of Chemistry, Vanderbilt University, Nashville, TN 37235 (United States); Hanusa, Timothy P., E-mail: t.hanusa@vanderbilt.ed [Department of Chemistry, Vanderbilt University, Nashville, TN 37235 (United States)

    2009-12-04

    The synthesis of mono(cyclopentadienyl)aryloxide complexes of calcium and barium has been investigated. The reaction of ICa(ODipp)(thf){sub 4} (Odipp = [2,6-iPr-OC{sub 6}H{sub 3}O]{sup -}) with K[C{sub 5}Me{sub 5}], (Cp{sup 3Si}){sub 2}Ca (Cp{sup 3Si} = C{sub 5}(SiMe{sub 3}){sub 3}H{sub 2}) with K[ODipp], and IBa(BHT)(thf){sub 3} (BHT = [2,6-tBu-4-Me-C{sub 6}H{sub 2}O]{sup -}) with K[C{sub 5}Me{sub 5}] in THF produces Cp*Ca(Odipp)(thf){sub 3}, (Cp{sup 3Si})Ca(Odipp)(thf){sub 2}, and Cp*Ba(BHT)(thf), respectively. The crystal structures of the two monomeric calcium complexes are reported. All three compounds are stable against Schlenk rearrangement in THF and aromatic solvents. DFT calculations suggest that the presence of THF has less of an effect on the thermodynamics of Schlenk rearrangements of the aryloxide systems than it does on comparable Cp'CaI compounds.

  19. Barium variation in Acropora palmata and Montastrea annularis

    Science.gov (United States)

    Pingitore, Nicholas E.; Rangel, Yolanda; Kwarteng, Andrew

    1989-06-01

    The barium contents of Acropora palmata and Montastrea annularis are distinct both in their averages (6 and 9 ppm, respectively) and, more impressively, in their variability (5 to 7 ppm and 6 to 15 ppm). A. palmata contained about 50% more Ba2+ than M. annularis and exhibited more than three times as much variation, as measured by their respective coefficients of variation. In contrast, the means and coefficients of variation of Sr2+ in these groups differed by only 6% and 15%. No obvious environmental or post-depositional causes for the inter-and intra-specific variation of Ba2+ could be found. Previous experiments indicate that the partitioning of Ba2+ into aragonite depends directly on the rate of precipitation. This suggests that Ba2+ does not substitute for Ca2+ but instead is incorporated by occlusion. Since growth rates in A. palmata often exceed those of M. annularis, this appears to be the mechanism which generates higher and more variable concentrations of Ba2+ in A. palmata.

  20. Medical and occupational dose reduction in pediatric barium meal procedures

    Science.gov (United States)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Ledesma, J. A.; Legnani, A.; Bunick, A. P.; Sauzen, J.; Yagui, A.; Vosiak, P.

    2017-11-01

    Doses received in pediatric Barium Meal procedure can be rather high. It is possible to reduce dose values following the recommendations of the European Communities (EC) and the International Commission on Radiological Protection (ICRP). In the present work, the modifications of radiographic techniques made in a Brazilian hospital according to the EC and the ICRP recommendations and their influence on medical and occupational exposure are reported. The procedures of 49 patients before and 44 after the optimization were studied and air kerma-area product (PK,A) values and the effective doses were evaluated. The occupational equivalent doses were measured next to the eyes, under the thyroid shield and on each hand of both professionals who remained inside the examination room. The implemented modifications reduced by 70% and 60% the PK,A and the patient effective dose, respectively. The obtained dose values are lower than approximately 75% of the results from similar studies. The occupational annual equivalent doses for all studied organs became lower than the limits set by the ICRP. The equivalent doses in one examination were on average below than 75% of similar studies.

  1. Barium oxide, calcium oxide, magnesia, and alkali oxide free glass

    Science.gov (United States)

    Lu, Peizhen Kathy; Mahapatra, Manoj Kumar

    2013-09-24

    A glass composition consisting essentially of about 10-45 mole percent of SrO; about 35-75 mole percent SiO.sub.2; one or more compounds from the group of compounds consisting of La.sub.2O.sub.3, Al.sub.2O.sub.3, B.sub.2O.sub.3, and Ni; the La.sub.2O.sub.3 less than about 20 mole percent; the Al.sub.2O.sub.3 less than about 25 mole percent; the B.sub.2O.sub.3 less than about 15 mole percent; and the Ni less than about 5 mole percent. Preferably, the glass is substantially free of barium oxide, calcium oxide, magnesia, and alkali oxide. Preferably, the glass is used as a seal in a solid oxide fuel/electrolyzer cell (SOFC) stack. The SOFC stack comprises a plurality of SOFCs connected by one or more interconnect and manifold materials and sealed by the glass. Preferably, each SOFC comprises an anode, a cathode, and a solid electrolyte.

  2. Obtaining of a barium compound by combustion chemistry and their evaluation as Co adsorbent

    International Nuclear Information System (INIS)

    Rosas G, N.

    2008-01-01

    In this work, barium carbonate synthesized by chemical combustion method using a chemical precursor prepared by the combination of barium nitrate and urea as a fuel, with a 1:1 molar ratio in aqueous solution, the chemical precursor was heated to evaporate excess water, producing a homogeneous viscous liquid, that when heated to 900 centi grades for 5 minutes an exothermic reaction was produced very quickly and abruptly, forming a white powder final product, fine porous, little spongy, dry and crystalline ready to be used as material adsorbent. Additionally, the effect of water on the synthesis by chemical combustion was studied. Simultaneously, and with the purpose of comparing the advantages and disadvantages of the method by chemical combustion, barium carbonate was synthesized by precipitation method using barium nitrate salts and sodium carbonate. Synthesized barium carbonate, was characterized by X-ray diffraction, thermal gravimetric analysis, infrared spectrometry and scanning electron microscopy. We studied the adsorption capacity of Co present in aqueous solution by static tests on materials synthesized at room temperature using the neutron activation analysis. It was found that the synthesis by chemical combustion provides an interesting alternative compared to the synthesis by precipitation because it offers simplicity of synthesis and speed to have a good adsorbent material. It was found that the barium carbonate synthesized by the chemical combustion method using in their synthesis 1.0 ml of water, was the one who achieved the maximum adsorption capacity of 95.6% compared with the barium carbonate prepared by precipitation, which reached a capacity adsorption of 51.48%. (Author)

  3. Rapid and accurate determination of barium by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Armelin, Maria Jose A.; Maihara, Vera A.; Saiki, Mitiko; Trevizam, Anderson R.

    2013-01-01

    Barium is an alkaline earth metal naturally present in soils. When available at a high level in the soil it can cause toxicity to plants and animals. Not all the barium is readily available to living organisms. Inorganic and organic barium compounds can be presented as soluble or insoluble forms in the soil. The soluble form of BaS is extremely toxic to humans, animals and plants. Researchers have noted a decrease of K absorption in the plant when Ba concentrations are increased and a change in overall plant growth. In case of animals, Ba tends to be concentrated in the bones which may compete with calcium, although only about 2% barium ingested in dietary is absorbed by the body. Another effect is that the Ba can interfere with the availability of sulfur in the soil due to the sulphate formation of low solubility. Barium and some other elements are considered palioclimatic proxies. For some researchers, barite is perhaps the most appropriate indicator of paleoproductivity because of a high resistance to dissolution. As explained about the barium effects in various situations, it was considered important to study the more appropriated experimental conditions for determination of this element by INAA. Conditions established for this analysis were: a) Irradiation time, 15 and 40 seconds, under thermal flux neutron about 4 x 10 12 n cm -2 s -1 , for determining barium in geological and biological matrices, respectively; b) Decay time, approximately of 4 minutes; c) Counting time of 30 minutes; d) Radionuclide measured 139 Ba. The quality of Ba results was evaluated from the analysis of certified reference materials. The performance of the method was satisfactory, according to the criterion of E.ζ score. Results obtained in this study indicate INAA is a good alternative for Ba determination in geological and biological samples. (author)

  4. Fluoroscopy-guided barium marking for localizing small pulmonary lesions before video-assisted thoracoscopic surgery

    International Nuclear Information System (INIS)

    Yamada, Takahiro; Koyama, Yasunori; Masui, Asami

    2009-01-01

    Small pulmonary lesions not previously seen on chest radiographs will likely be detected with increasing frequency because of the spread of CT screening. For the diagnosis and treatment of such lesions, we frequently perform resection by video-assisted thoracoscopic surgery (VATS). We performed fluoroscopy-guided barium marking for localization of small peripheral pulmonary lesions before VATS resection, and examined its reliability, safety, and usefulness. We studied 46 patients with peripheral pulmonary lesions 20 mm or less in diameter who were scheduled to undergo VATS resection. The average diameter of the lesions was 10.2±0.5 mm (mean±standard error), and the average distance from the pleural surface was 10.1±0.8 mm. The optimal site for the catheter tip was decided on chest radiographs using CT scans for reference beforehand, and a catheter was inserted bronchoscopically into the target segment and guided to the presumed lesion. A 50% (weight/volume) barium sulfate suspension was instilled into the bronchus through the catheter, and the site of barium marking was checked by CT scanning. The average instilled volume of barium was 0.36±0.03 ml. On CT scans, barium spots were superimposed on the target lesions in 35 of the 46 patients and were only 15 mm from the lesions in the other patients. Barium was well recognized in all patients at the time of VATS resection, and we could confirm the diagnosis in all patients. A mild cough persisted for about 1 week in 1 patient, but the other patients had no specific complications. Fluoroscopy-guided barium marking is a safe, convenient, and reliable method for localization of small pulmonary lesions before VATS resection. (author)

  5. [Value of preoperative barium contrast examination for the diagnosis and operative planning in gastric cancer].

    Science.gov (United States)

    Wang, Chang-jian; Zhao, Guang-fa; Li, Qing-guo; Chen, Jing-gui; Zhu, Kai; Shi, Ying-qiang; Fu, Hong

    2010-04-01

    To investigate the value of preoperative barium contrast examination for the diagnosis and operative planning in gastric cancer. Clinical data of 229 gastric cancer patients were analyzed retrospectively. Lesions were divided into three parts: the cardiac, the body, and the antrum. The diagnostic accuracy of localization and the extent of tumor between gastroscopy alone and gastroscopy plus barium contrast were compared with the results of surgical findings. The diagnostic accuracy of localization and the extent of tumor for gastroscopy in the cardiac, the body and the antrum cancers were 100% and 78.4%, 94.6% and 86.5%, 98.1% and 84.6%, respectively, while for gastroscopy plus barium contrast were 100% and 84.8%, 100% and 91.9%, 99.0% and 90.4%, respectively. The diagnostic accuracy of both the localization and the extent of tumor were not significantly different between gastroscopy alone and gastroscopy plus barium contrast (P>0.05). Diagnostic accuracy of the length of esophagus infiltrated by cardiac cancer in gastroscopy was 60.6%, while in gastroscopy plus barium contrast was 90.9%, which was significantly different (Pbarium contrast was more accurate in predicting the possibility of thoracotomy in cardiac cancer infiltrating the lower esophagus. It is necessary to perform preoperative barium contrast examination in cardiac cancer patients, so as to identify whether the lower esophagus is infiltrated and to measure the length of lesion, which can provide evidences for making a decision of thoracotomy. For gastric body and antrum cancer, there is no indication for barium contrast examination if gastroscopy findings are satisfied.

  6. Accelerating the transit time of barium sulphate suspensions in small bowel examinations

    International Nuclear Information System (INIS)

    Summers, David S.; Roger, Mark D.; Allan, Paul L.; Murchison, John T.

    2007-01-01

    Purpose: To determine whether hyperosmolar and effervescent agents proven individually to accelerate transit time in the barium small bowel examination have an additive effect when combined, surpassing that of either agent alone. Materials and methods: One hundred and forty-nine patients were randomised to four groups. Three hundred milliliters of barium sulphate alone was given to the first group. Fifteen milliliters of iodinated hyperosmolar contrast agent (Gastrografin, meglumine/sodium diatrizoate, Schering) was given in addition to barium sulphate to the second group while six packets of effervescent granules (Carbex, Ferring) were added for the third group. The final group was given a combination of both additives and barium sulphate. The time taken following ingestion for the contrast column to reach the caecum, as assessed by frequent interval fluoroscopy, was recorded. A subgroup of 32 patients were selected randomly from the four groups, 8 from each and assessed for quality of examination. Statistical assessments were made using Kruskal-Wallis and Mann-Whitney tests. Results: One hundred and nineteen patients were analysed after exclusions. The addition of accelerant to barium sulphate, both individually and in combination significantly reduced the small bowel transit time (p < 0.001). No significant difference existed between the additives when used with barium alone. The combined group had significantly faster transit times compared to the hyperosmolar group (p = 0.02). Differences between combined and effervescent groups tended towards significance (p = 0.09). No significant difference existed between groups when examination quality was assessed. Conclusion: These results suggest that the addition of combined effervescent and hyperosmolar agents to the barium suspension may significantly shorten the small bowel transit time without adversely affecting examination quality. This has implications for patient acceptability of the examination as well as

  7. Barium inhibits arsenic-mediated apoptotic cell death in human squamous cell carcinoma cells.

    Science.gov (United States)

    Yajima, Ichiro; Uemura, Noriyuki; Nizam, Saika; Khalequzzaman, Md; Thang, Nguyen D; Kumasaka, Mayuko Y; Akhand, Anwarul A; Shekhar, Hossain U; Nakajima, Tamie; Kato, Masashi

    2012-06-01

    Our fieldwork showed more than 1 μM (145.1 μg/L) barium in about 3 μM (210.7 μg/L) arsenic-polluted drinking well water (n = 72) in cancer-prone areas in Bangladesh, while the mean concentrations of nine other elements in the water were less than 3 μg/L. The types of cancer include squamous cell carcinomas (SCC). We hypothesized that barium modulates arsenic-mediated biological effects, and we examined the effect of barium (1 μM) on arsenic (3 μM)-mediated apoptotic cell death of human HSC-5 and A431 SCC cells in vitro. Arsenic promoted SCC apoptosis with increased reactive oxygen species (ROS) production and JNK1/2 and caspase-3 activation (apoptotic pathway). In contrast, arsenic also inhibited SCC apoptosis with increased NF-κB activity and X-linked inhibitor of apoptosis protein (XIAP) expression level and decreased JNK activity (antiapoptotic pathway). These results suggest that arsenic bidirectionally promotes apoptotic and antiapoptotic pathways in SCC cells. Interestingly, barium in the presence of arsenic increased NF-κB activity and XIAP expression and decreased JNK activity without affecting ROS production, resulting in the inhibition of the arsenic-mediated apoptotic pathway. Since the anticancer effect of arsenic is mainly dependent on cancer apoptosis, barium-mediated inhibition of arsenic-induced apoptosis may promote progression of SCC in patients in Bangladesh who keep drinking barium and arsenic-polluted water after the development of cancer. Thus, we newly showed that barium in the presence of arsenic might inhibit arsenic-mediated cancer apoptosis with the modulation of the balance between arsenic-mediated promotive and suppressive apoptotic pathways.

  8. Chloride Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/chloridebloodtest.html Chloride Blood Test To use the sharing features on this page, please enable JavaScript. What is a Chloride Blood Test? A chloride blood test measures the ...

  9. Effects of platinic chloride on Tetrahymena pyrifromis GL

    DEFF Research Database (Denmark)

    Nilsson, Jytte R.

    1992-01-01

    Cellebiologi, platinum(IV)chloride, endocytosis, detoxification, cell proliferation, fine structure, cisplatin......Cellebiologi, platinum(IV)chloride, endocytosis, detoxification, cell proliferation, fine structure, cisplatin...

  10. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, N.G. [University of Otago, Department of Radiology, Christchurch (New Zealand); Butler, A.P. [University of Otago, Department of Radiology, Christchurch (New Zealand); University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Scott, N.J.A. [University of Otago, Department of Medicine, Christchurch (New Zealand); Cook, N.J. [Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Butzer, J.S. [Karlsruhe Institute of Technology, Physics Department, Karlsruhe (Germany); Schleich, N. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand); Christchurch Hospital, Medical Physics and Bioengineering, Christchurch (New Zealand); Firsching, M. [Friedrich Alexander University, Physics Department, Erlangen (Germany); Grasset, R.; Ruiter, N. de [University of Canterbury, Hitlab NZ, Christchurch (New Zealand); Campbell, M. [European Organisation for Nuclear Research, Physics Section, Geneva (Switzerland); Butler, P.H. [University of Canterbury, Physics and Astronomy, Christchurch (New Zealand)

    2010-09-15

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 {mu}A). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at <55 {mu}m isotropic voxels. Spectral CT distinguishes contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications. (orig.)

  11. Determination of barium in surface and ground waters at Centro Experimental Aramar area

    Energy Technology Data Exchange (ETDEWEB)

    Matoso, Erika, E-mail: ematoso@hotmail.com [Centro Tecnologico da Marinha em Sao Paulo (CEA/CTMS), Ipero, SP (Brazil). Centro Experimental Aramar; Cadore, Solange, E-mail: cadore@iqm.unicamp.br [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Instituto de Quimica. Departamento de Quimica Analica

    2015-07-01

    Barium can be found in waters up to 1 mg L{sup -1} and came from natural sources such as sedimentary rocks erosion rich in feldspar and barite. Also anthropogenic activities can release this element such as oil and gas industry, agricultural defensives, chemical industry and waste disposal. At high doses, barium can be harmful to human central nervous system and can also cause high blood pressure, heart problems, fatigue and anxiety. The water potability defined by Brazilian's Ministry of Healthy sets barium concentration up to 0.7 mg L{sup -1} and official regulation defines the same limit of this element to superficial waters (according CONAMA resolution 357/2005) and ground waters (Sao Paulo state regulation). In this work, barium was analyzed monthly in superficial waters from 4 different sampling locations, located in a ratio of 10-km-long from Centro Experimental Aramar (CEA) at Ipanema River, during one year, in order to evaluate the river in different conditions (seasons, temperature and rain period). The ground water was collected every six months. The analytical technique applied was ICP OES and the method conditions were optimized: wavelength, linearity, signal background ratio, detection and quantification limits. Data obtained in this work will contribute to evaluate the presence of barium at CEA region and nearby in order to compare it with current Brazilian regulations. (author)

  12. Radiologic diagnosis of gastro-oesophageal reflux. Comparison of barium and low-density contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G.; Soekjer, H.; Johansson, K.E.; Tibbling, L.

    It has been proposed that the high density of ordinary barium suspension may complicate the radiologic diagnosis of gastro-oesophageal reflux. For this reason P-contrast was developed (Ferring AB); a contrast medium with the same density as water (1 g/cm/sup 3/). A comparison of P-contrast and barium (Mixobar Ventrikel 400 mg/ml) was performed in 82 patients. All patients were examined with both contrast media and the findings were compared with those at reflux test at manometry, endoscopy and 24-hour pH monitoring. Another 40 patients and 15 symptom-free controls were examined with two different amounts of barium, 100 ml and 200 ml, to study if the radiologic diagnosis of reflux varied with the volume of contrast medium administered. P-contrast was found to have no advantages over barium for the diagnosis of gastro-oesophageal reflux. The outcome of the radiologic examination was not influenced by the different volumes of barium used.

  13. Benefits of Barium Enema in Patients with Incomplete Colonoscopy. Prospective Study of 45 Cases

    International Nuclear Information System (INIS)

    Gispert, S.; Mayolas, N.; Hidalgo, A.

    2003-01-01

    To evaluate the usefulness of barium enema in patients with incomplete colonoscopy. There was carried out a prospective 10-month study of 45 patients with incomplete colonoscopy (27 men and 18 women), who were later examined by means of barium enema (33 conventional, 12 double-contrast) in order to check for additional pathology in portions of the colon not visualized by colonoscopy. Barium enema diagnosed six possible additional lesions (13.3%) in portions of the colon not visualized by incomplete colonoscopy (four neoplasia and two non-neoplasia). Regarding the neoplasia two were true positives and two false positives. Both true positives were adenocarcinomas (one synchronous caecum, and another in splenic angle). The two false positives corresponded to fecal matter stuck to the intestinal wall. Regarding the non-neoplasia, multiple stenosis was detected in a patient with Crohn's disease and an enterocolic fistula was found in a patient with sigmoid colon neoplasia. The diagnostic yield of barium enema in the detection of additional pathology in colon portions not visualized by colonoscopy was of 9%. Barium enema following incomplete colonoscopy permits a complete colon evaluation in most cases, and it offers additional diagnostic information. (Author) 21 refs

  14. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.

    Science.gov (United States)

    Anderson, N G; Butler, A P; Scott, N J A; Cook, N J; Butzer, J S; Schleich, N; Firsching, M; Grasset, R; de Ruiter, N; Campbell, M; Butler, P H

    2010-09-01

    Spectral CT differs from dual-energy CT by using a conventional X-ray tube and a photon-counting detector. We wished to produce 3D spectroscopic images of mice that distinguished calcium, iodine and barium. We developed a desktop spectral CT, dubbed MARS, based around the Medipix2 photon-counting energy-discriminating detector. The single conventional X-ray tube operated at constant voltage (75 kVp) and constant current (150 microA). We anaesthetised with ketamine six black mice (C57BL/6). We introduced iodinated contrast material and barium sulphate into the vascular system, alimentary tract and respiratory tract as we euthanised them. The mice were preserved in resin and imaged at four detector energy levels from 12 keV to 42 keV to include the K-edges of iodine (33.0 keV) and barium (37.4 keV). Principal component analysis was applied to reconstructed images to identify components with independent energy response, then displayed in 2D and 3D. Iodinated and barium contrast material was spectrally distinct from soft tissue and bone in all six mice. Calcium, iodine and barium were displayed as separate channels on 3D colour images at contrast agents with K-edges only 4 keV apart. Multi-contrast imaging and molecular CT are potential future applications.

  15. Effect of barium sulfate contrast medium on rheology and sensory texture attributes in a model food.

    Science.gov (United States)

    Ekberg, O; Bulow, M; Ekman, S; Hall, G; Stading, M; Wendin, K

    2009-03-01

    The swallowing process can be visualized using videoradiography, by mixing food with contrast medium, e.g., barium sulfate (BaSO(4)), making it radiopaque. The sensory properties of foods may be affected by adding this medium. To evaluate if and to what extent sensory and rheological characteristics of mango purée were altered by adding barium sulfate to the food. This study evaluated four food samples based on mango purée, with no or added barium sulfate contrast medium (0%, 12.5%, 25.0%, and 37.5%), by a radiographic method, and measured sensory texture properties and rheological characteristics. The sensory evaluation was performed by an external trained panel using quantitative descriptive analysis. The ease of swallowing the foods was also evaluated. The sensory texture properties of mango purée were significantly affected by the added barium in all evaluated attributes, as was the perception of particles. Moreover, ease of swallowing was significantly higher in the sample without added contrast medium. All samples decreased in extensional viscosity with increasing extension rate, i.e., all samples were tension thinning. Shear viscosity was not as dependent on the concentration of BaSO(4) as extensional viscosity. Addition of barium sulfate to a model food of mango purée has a major impact on perceived sensory texture attributes as well as on rheological parameters.

  16. Determination of barium in surface and ground waters at Centro Experimental Aramar area

    International Nuclear Information System (INIS)

    Matoso, Erika; Cadore, Solange

    2015-01-01

    Barium can be found in waters up to 1 mg L -1 and came from natural sources such as sedimentary rocks erosion rich in feldspar and barite. Also anthropogenic activities can release this element such as oil and gas industry, agricultural defensives, chemical industry and waste disposal. At high doses, barium can be harmful to human central nervous system and can also cause high blood pressure, heart problems, fatigue and anxiety. The water potability defined by Brazilian's Ministry of Healthy sets barium concentration up to 0.7 mg L -1 and official regulation defines the same limit of this element to superficial waters (according CONAMA resolution 357/2005) and ground waters (Sao Paulo state regulation). In this work, barium was analyzed monthly in superficial waters from 4 different sampling locations, located in a ratio of 10-km-long from Centro Experimental Aramar (CEA) at Ipanema River, during one year, in order to evaluate the river in different conditions (seasons, temperature and rain period). The ground water was collected every six months. The analytical technique applied was ICP OES and the method conditions were optimized: wavelength, linearity, signal background ratio, detection and quantification limits. Data obtained in this work will contribute to evaluate the presence of barium at CEA region and nearby in order to compare it with current Brazilian regulations. (author)

  17. Colonoscopy can miss diverticula of the left colon identified by barium enema.

    Science.gov (United States)

    Niikura, Ryota; Nagata, Naoyoshi; Shimbo, Takuro; Akiyama, Junichi; Uemura, Naomi

    2013-04-21

    To identify the diagnostic value of colonoscopy for diverticulosis as determined by barium enema. A total of 65 patients with hematochezia who underwent colonoscopy and barium enema were analyzed, and the diagnostic value of colonoscopy for diverticula was assessed. The receiver operating characteristic area under the curve was compared in relation to age (barium enema. Colonoscopy had a sensitivity of 91% and specificity of 90%. No significant differences were found in the receiver operating characteristic area under the curve (ROC-AUC) for age group or sex. The ROC-AUC of the left colon was significantly lower than that of the right colon (0.81 vs 0.96, P = 0.02). Colonoscopy identified 486 colonic diverticula, while barium enema identified 1186. The detection ratio for the entire colon was therefore 0.41 (486/1186). The detection ratio in the left colon (0.32, 189/588) was significantly lower than that of the right colon (0.50, 297/598) (P barium enema, only half the number of colonic diverticula can be detected by colonoscopy in the entire colon and even less in the left colon.

  18. Chloride Transport in Undersea Concrete Tunnel

    Directory of Open Access Journals (Sweden)

    Yuanzhu Zhang

    2016-01-01

    Full Text Available Based on water penetration in unsaturated concrete of underwater tunnel, a diffusion-advection theoretical model of chloride in undersea concrete tunnel was proposed. The basic parameters including porosity, saturated hydraulic conductivity, chloride diffusion coefficient, initial water saturation, and moisture retention function of concrete specimens with two water-binder ratios were determined through lab-scale experiments. The variation of chloride concentration with pressuring time, location, solution concentration, initial saturation, hydraulic pressure, and water-binder ratio was investigated through chloride transport tests under external water pressure. In addition, the change and distribution of chloride concentration of isothermal horizontal flow were numerically analyzed using TOUGH2 software. The results show that chloride transport in unsaturated concrete under external water pressure is a combined effect of diffusion and advection instead of diffusion. Chloride concentration increased with increasing solution concentration for diffusion and increased with an increase in water pressure and a decrease in initial saturation for advection. The dominant driving force converted with time and saturation. When predicting the service life of undersea concrete tunnel, it is suggested that advection is taken into consideration; otherwise the durability tends to be unsafe.

  19. Factors influencing chloride deposition in a coastal hilly area and application to chloride deposition mapping

    Directory of Open Access Journals (Sweden)

    H. Guan

    2010-05-01

    Full Text Available Chloride is commonly used as an environmental tracer for studying water flow and solute transport in the environment. It is especially useful for estimating groundwater recharge based on the commonly used chloride mass balance (CMB method. Strong spatial variability in chloride deposition in coastal areas is one difficulty encountered in appropriately applying the method. A high-resolution bulk chloride deposition map in the coastal region is thus needed. The aim of this study is to construct a chloride deposition map in the Mount Lofty Ranges (MLR, a coastal hilly area of approximately 9000 km2 spatial extent in South Australia. We examined geographic (related to coastal distance, orographic, and atmospheric factors that may influence chloride deposition, using partial correlation and regression analyses. The results indicate that coastal distance, elevation, as well as terrain aspect and slope, appear to be significant factors controlling chloride deposition in the study area. Coastal distance accounts for 70% of spatial variability in bulk chloride deposition, with elevation, terrain aspect and slope an additional 15%. The results are incorporated into a de-trended residual kriging model (ASOADeK to produce a 1 km×1 km resolution bulk chloride deposition and concentration maps. The average uncertainty of the deposition map is about 20–30% in the western MLR, and 40–50% in the eastern MLR. The maps will form a useful basis for examining catchment chloride balance for the CMB application in the study area.

  20. Reducing conditions on barium absorption in rice plants cultured in BaSO4-enriched soil doi: 10.4025/actasciagron.v36i1.17539

    Directory of Open Access Journals (Sweden)

    Marcio Osvaldo Lima Magalhães

    2014-01-01

    Full Text Available To evaluate the possible solubilization of barium sulfate in soils under reducing conditions and its effects on barium bioavailability, an Oryza sativa pot trial was established. Increasing barium doses and two redox potential conditions were evaluated. The geochemical fractionation data demonstrated that reducing conditions led to an increase in the levels of more labile forms of barium and a reduction in more stable forms. Furthermore, higher doses of barium were found to have a negative impact on grain production. The highest levels of barium accumulation in the leaves, roots, and grains were observed with the highest barium dose under reducing conditions. These results demonstrate that reducing conditions increased barium bioavailability and absorption by rice plants.