WorldWideScience

Sample records for iris pigmentary change

  1. Genome-wide association study of pigmentary traits (skin and iris color in individuals of East Asian ancestry

    Directory of Open Access Journals (Sweden)

    Lida Rawofi

    2017-11-01

    Full Text Available Background Currently, there is limited knowledge about the genetics underlying pigmentary traits in East Asian populations. Here, we report the results of the first genome-wide association study of pigmentary traits (skin and iris color in individuals of East Asian ancestry. Methods We obtained quantitative skin pigmentation measures (M-index in the inner upper arm of the participants using a portable reflectometer (N = 305. Quantitative measures of iris color (expressed as L*, a* and b* CIELab coordinates were extracted from high-resolution iris pictures (N = 342. We also measured the color differences between the pupillary and ciliary regions of the iris (e.g., iris heterochromia. DNA samples were genotyped with Illumina’s Infinium Multi-Ethnic Global Array (MEGA and imputed using the 1000 Genomes Phase 3 samples as reference haplotypes. Results For skin pigmentation, we did not observe any genome-wide significant signal. We followed-up in three independent Chinese samples the lead SNPs of five regions showing multiple common markers (minor allele frequency ≥ 5% with good imputation scores and suggestive evidence of association (p-values < 10−5. One of these markers, rs2373391, which is located in an intron of the ZNF804B gene on chromosome 7, was replicated in one of the Chinese samples (p = 0.003. For iris color, we observed genome-wide signals in the OCA2 region on chromosome 15. This signal is driven by the non-synonymous rs1800414 variant, which explains 11.9%, 10.4% and 6% of the variation observed in the b*, a* and L* coordinates in our sample, respectively. However, the OCA2 region was not associated with iris heterochromia. Discussion Additional genome-wide association studies in East Asian samples will be necessary to further disentangle the genetic architecture of pigmentary traits in East Asian populations.

  2. Retrospective Evaluation of Topical Bimatoprost and Iris Pigmentation Change.

    Science.gov (United States)

    Zaleski-Larsen, Lisa A; Ruth, Nadine H; Fabi, Sabrina G

    2017-12-01

    Topical bimatoprost is a topical prostaglandin analog originally used to treat glaucoma and more recently used to cosmetically induce hypertrichosis of the eyelashes. Iris pigmentation change has been noted in the treatment of glaucoma but has not been assessed with the cosmetic periorbital application of bimatoprost. To evaluate for iris pigmentation change with the long-term cosmetic use of topical bimatoprost. A retrospective chart review in a cosmetic dermatology practice of women (N = 50) who consistently purchased topical bimatoprost over an average of 4.59 years was compared with that of age-matched non-bimatoprost patients (N = 50). A blinded evaluator assessed each patient for iris pigmentary change. No iris pigmentation change was noted with the cutaneous application of bimatoprost. The cutaneous application of bimatoprost appears to be safe with minimal risk for iris pigmentation change.

  3. Retinal pigmentary changes in chronic uveitis mimicking retinitis pigmentosa.

    Science.gov (United States)

    Sevgi, D Damla; Davoudi, Samaneh; Comander, Jason; Sobrin, Lucia

    2017-09-01

    To present retinal pigmentary changes mimicking retinitis pigmentosa (RP) as a finding of advanced uveitis. We retrospectively reviewed charts of patients without a family history of inherited retinal degenerations who presented with retinal pigment changes and signs of past or present intraocular inflammation. Comprehensive eye examination including best-corrected visual acuity, slit-lamp examination and dilated fundus examination was performed on all patients in addition to color fundus photography, optical coherence tomography, fluorescein angiography (FA), and full-field electroretinogram testing. We identified five patients with ages ranging from 33 to 66 years, who presented with RP-like retinal pigmentary changes which were eventually attributed to longstanding uveitis. The changes were bilateral in three cases and unilateral in two cases. Four of five cases presented with active inflammation, and the remaining case showed evidence of active intraocular inflammation during follow-up. This study highlights the overlapping features of advanced uveitis and RP including the extensive pigmentary changes. Careful review of possible past uveitis history, detailed examination of signs of past or present inflammation and ancillary testing, with FA often being most helpful, are required for the correct diagnosis. This is important, because intervention can prevent further damage if the cause of the pigmentary changes is destructive inflammation.

  4. Pigment dispersion syndrome and pigmentary glaucoma--a major review.

    Science.gov (United States)

    Niyadurupola, Nuwan; Broadway, David C

    2008-12-01

    Pigment dispersion syndrome (PDS) is an interesting condition that can lead to secondary open angle glaucoma. Pigmentary glaucoma is primarily a disease of young people, myopes and men. PDS is characterized by the presence of Krukenberg spindles, iris trans-illumination defects, trabecular meshwork pigmentation and backward bowing of the iris. Posterior bowing of the iris causes rubbing of the pigmented iris epithelium against lens structures, liberation of pigment and trabecular meshwork changes that result in reduced aqueous outflow with the risk of glaucoma. Peripheral laser iridotomy can reverse backward bowing of the iris and may prevent progression of pigmentary glaucoma.

  5. Does Iris Change Over Time?

    Science.gov (United States)

    Mehrotra, Hunny; Vatsa, Mayank; Singh, Richa; Majhi, Banshidhar

    2013-01-01

    Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008–2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs. PMID:24244305

  6. Does iris change over time?

    Science.gov (United States)

    Mehrotra, Hunny; Vatsa, Mayank; Singh, Richa; Majhi, Banshidhar

    2013-01-01

    Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008-2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs.

  7. Does iris change over time?

    Directory of Open Access Journals (Sweden)

    Hunny Mehrotra

    Full Text Available Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008-2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs.

  8. Peripheral iridotomy for pigmentary glaucoma

    Science.gov (United States)

    Michelessi, Manuele; Lindsley, Kristina

    2016-01-01

    meaningful differences between groups (mean difference 0.04 mm, 95% CI −0.07 to 0.15; 14 eyes; very low-quality evidence). No other trial reported mean change in anterior chamber depth. Two trials reported greater flattening of iris configuration in the laser iridotomy group than in the control group among eyes with pigmentary glaucoma; however, investigators provided insufficient data for analysis. No trial reported data related to mean visual acuity, aqueous melanin granules, costs, or quality of life outcomes. Two trials assessed the need for additional treatment for control of IOP. One trial that enrolled participants with pigmentary glaucoma reported that more eyes in the laser iridotomy group required additional treatment between six and 23 months of follow-up than eyes in the control group (RR 1.73, 95% CI 1.08 to 2.75; 46 eyes); however, the other trial enrolled participants with pigment dispersion syndrome and indicated that the difference between groups at three-year follow-up was uncertain (RR 0.91, 95% CI 0.38 to 2.17; 105 eyes). We graded the certainty of evidence for this outcome as very low. Two trials reported that no serious adverse events were observed in either group among eyes with pigment dispersion syndrome. Mild adverse events included postoperative inflammation; two participants required cataract surgery (at 18 and 34 months after baseline), and two participants required a repeat iridotomy. Authors' conclusions We found insufficient evidence of high quality on the effectiveness of peripheral iridotomy for pigmentary glaucoma or pigment dispersion syndrome. Although adverse events associated with peripheral iridotomy may be minimal, the long-term effects on visual function and other patient-important outcomes have not been established. Future research on this topic should focus on outcomes that are important to patients and the optimal timing of treatment in the disease process (eg, pigment dispersion syndrome with normal IOP, pigment dispersion

  9. Changes of the eye optics after iris constriction

    Directory of Open Access Journals (Sweden)

    Robert Montés-Micó

    2010-10-01

    Conclusion: Iris constriction slightly modifies the optics of the eye. The small hyperopic shift of the best image plane after iris constriction may be explained by a change in the lens shape and/or position.

  10. Pigmentary glaucoma accompanied by Usher syndrome.

    Science.gov (United States)

    Koucheki, Behrooz; Jalali, Kamran Hodjat

    2012-08-01

    To report a case of pigmentary glaucoma (PG) accompanied by Usher syndrome. Case report. The results were presented after standard ocular examination, visual field test, anterior segment and fundus photography, electroretinography, and otolaryngology consultation were conducted. Typical retinitis pigmentosa, flat electroretinography, congenital sensorineural hearing loss, high intraocular pressure, Krukenberg spindle, iris concavity, radial iris transillumination defect, severe pigment deposition on the trabecular meshwork, and glaucomatous optic nerve damage were indicative of PG accompanied by Usher syndrome. In some rare cases, PG may coexist with Usher syndrome. Common findings of Usher syndrome, including night blindness, impaired vision, visual field defects, and retinal changes may distract the clinician from considering the diagnosis of glaucoma. Such association should be borne in mind to make a timely diagnosis and treatment possible.

  11. IRIS

    International Nuclear Information System (INIS)

    Malfaro, W.; Zygmont, A.

    1991-01-01

    This paper discusses development of ISOLATION RESET INFORMATION SYSTEM (IRIS), an expert system to aid nuclear plant operators during plant transients known as automatic containment isolations. IRIS is implemented using the Personal Consultant Plus expert system shell, taking advantage of the dBase III Plus interface. The design of IRIS is discussed as well as the system's current state of development. The use of expert systems for training operators is discussed. The importance of gaining regulatory acceptance of expert systems is presented. This issue will ultimately determine the extent of expert system use in nuclear applications

  12. Progressive Pigmentary Purpura

    Science.gov (United States)

    ... Category: Share: Yes No, Keep Private Progressive Pigmentary Purpura Share | Progressive pigmentary purpura (we will call it PPP) is a group ... conditions ( Schamberg's disease , Lichenoid dermatitis of Gourgerot-Blum, purpura annularis telangiectodes of Majocchi and Lichen aureus). Schamberg's ...

  13. Update on pigment dispersion syndrome and pigmentary glaucoma.

    Science.gov (United States)

    Okafor, Kingsley; Vinod, Kateki; Gedde, Steven J

    2017-03-01

    The present article reviews the clinical features and pathogenesis of pigment dispersion syndrome and pigmentary glaucoma and provides an update regarding their diagnosis and management. Newer imaging modalities including ultrasound biomicroscopy and anterior segment optical coherence tomography facilitate visualization of the iris concavity characteristic of eyes with pigment dispersion syndrome and pigmentary glaucoma. Patients with pigmentary glaucoma may be distinguished from those with other glaucoma types by the presence of typical symptoms, personality type, and patterns of diurnal intraocular pressure fluctuation. Although laser iridotomy has been shown to alter iris anatomy in pigmentary glaucoma, it is not proven to slow visual field progression. Multiple trials have validated the safety and efficacy of filtering surgery in treating pigmentary glaucoma, with fewer studies published on the role of micro-invasive glaucoma surgery. Literature from the review period has further defined the unique clinical characteristics of pigment dispersion syndrome and pigmentary glaucoma. Laser surgery has a limited role in the management of these entities, whereas trabeculectomy remains an acceptable first-line surgical treatment. Further studies are needed to define the potential application of the newer micro-invasive glaucoma procedures in pigmentary glaucoma.

  14. Effect of epithalon on age-specific changes in the retina in rats with hereditary pigmentary dystrophy.

    Science.gov (United States)

    Khavinson, V Kh; Razumovskii, M I; Trofimova, S V; Grigor'yan, R A; Chaban, T V; Oleinik, T L; Razumovskaya, A M

    2002-01-01

    The effect of peptide bioregulator Epithalon on the course of hereditary pigmentary retinal degeneration was studied in Campbell rats. Administration of epithalon starting from birth protected morphological structure, increased its bioelectrical activity, and improved its function.

  15. MULTIMODAL IMAGING OF DISEASE-ASSOCIATED PIGMENTARY CHANGES IN RETINITIS PIGMENTOSA.

    Science.gov (United States)

    Schuerch, Kaspar; Marsiglia, Marcela; Lee, Winston; Tsang, Stephen H; Sparrow, Janet R

    2016-12-01

    Using multiple imaging modalities, we evaluated the changes in photoreceptor cells and retinal pigment epithelium (RPE) that are associated with bone spicule-shaped melanin pigmentation in retinitis pigmentosa. In a cohort of 60 patients with retinitis pigmentosa, short-wavelength autofluorescence, near-infrared autofluorescence (NIR-AF), NIR reflectance, spectral domain optical coherence tomography, and color fundus images were studied. Central AF rings were visible in both short-wavelength autofluorescence and NIR-AF images. Bone spicule pigmentation was nonreflective in NIR reflectance, hypoautofluorescent with short-wavelength autofluorescence and NIR-AF imaging, and presented as intraretinal hyperreflective foci in spectral domain optical coherence tomography images. In areas beyond the AF ring outer border, the photoreceptor ellipsoid zone band was absent in spectral domain optical coherence tomography and the visibility of choroidal vessels in short-wavelength autofluorescence, NIR-AF, and NIR reflectance images was indicative of reduced RPE pigmentation. Choroidal visibility was most pronounced in the zone approaching peripheral areas of bone spicule pigmentation; here RPE/Bruch membrane thinning became apparent in spectral domain optical coherence tomography. These findings are consistent with a process by which RPE cells vacate their monolayer and migrate into inner retina in response to photoreceptor cell degeneration. The remaining RPE spread undergo thinning and consequently become less pigmented. An explanation for the absence of NIR-AF melanin signal in relation to bone spicule pigmentation is not forthcoming.

  16. Multimodal Imaging of Disease-Associated Pigmentary Changes in Retinitis Pigmentosa

    Science.gov (United States)

    Schuerch, Kaspar; Marsiglia, Marcela; Lee, Winston; Tsang, Stephen H.; Sparrow, Janet R.

    2016-01-01

    Purpose Using multiple imaging modalities we evaluated the changes in photoreceptor cells and RPE that are associated with bone spicule-shaped melanin pigmentation in retinitis pigmentosa (RP). Methods In a cohort of 60 RP patients, short-wavelength autofluorescence (SW-AF), near-infrared (NIR)-AF, NIR-reflectance (NIR-R), spectral domain optical coherence tomography (SD-OCT) and color fundus images were studied. Results Central AF rings were visible in both SW-AF and NIR-AF images. Bone spicule pigmentation was non-reflective in NIR-R, hypoautofluorescent with SW-AF and NIR-AF imaging and presented as intraretinal hyperreflective foci in SD-OCT images. In areas beyond the AF ring outer border, the photoreceptor ellipsoid zone (EZ) band was absent in SD-OCT scans and the visibility of choroidal vessels in SW-AF, NIR-AF and NIR-R images was indicative of reduced RPE pigmentation. Choroidal visibility was most pronounced in the zone approaching peripheral areas of bone spicule pigmentation; here RPE/Bruch’s membrane thinning became apparent in SD-OCT scans. Conclusions These findings are consistent with a process by which RPE cells vacate their monolayer and migrate into inner retina in response to photoreceptor cell degeneration. The remaining RPE spread, undergo thinning and consequently become less pigmented. An explanation for the absence of NIR-AF melanin signal in relation to bone spicule pigmentation is not forthcoming. PMID:28005673

  17. What is the risk of developing pigmentary glaucoma from pigment dispersion syndrome?

    Science.gov (United States)

    Siddiqui, Yasmin; Ten Hulzen, Richard D; Cameron, J Douglas; Hodge, David O; Johnson, Douglas H

    2003-06-01

    To determine the probability of converting from pigment dispersion syndrome to pigmentary glaucoma. Retrospective community-based study of all newly diagnosed cases of pigment dispersion syndrome or pigmentary glaucoma. Subjects were patients newly diagnosed with pigment dispersion syndrome or pigmentary glaucoma from 1976 to 1999 in Olmsted County, Minnesota. Criteria for pigment dispersion syndrome were two of three signs: midperipheral, radial iris transillumination defects; Krukenberg spindle; heavy trabecular meshwork pigmentation. Criteria for pigmentary glaucoma were pigment dispersion syndrome and two of three findings: intraocular pressure (IOP) greater than 21 mm, optic nerve damage, or visual field loss. Kaplan-Meier survival curves were used to determine the probability of conversion to pigmentary glaucoma. A total of 113 patients were newly diagnosed with pigment dispersion syndrome over the 24-year period. Of these, 9 persons developed pigmentary glaucoma or elevated IOP requiring therapy. The probability of converting to pigmentary glaucoma was 10% at 5 years and 15% at 15 years. An additional 23 patients were found to have pigmentary glaucoma at their initial examination. The mean age at diagnosis of pigmentary glaucoma was 42 +/- 12 years; 78% of patients were male, whereas 58% of patients with pigmentary dispersion syndrome glaucoma were male. The most significant risk factor for conversion to pigmentary glaucoma was an IOP greater than 21 mm Hg at initial examination, whereas age, refractive error, and family history of glaucoma were not correlated with conversion. The risk of developing pigmentary glaucoma from pigment dispersion syndrome was 10% at 5 years and 15% at 15 years. Young, myopic men were most likely to have pigmentary glaucoma. An IOP greater than 21 mm Hg at initial examination was associated with an increased risk of conversion.

  18. Infantile spasms and pigmentary mosaicism

    DEFF Research Database (Denmark)

    Hansen, Lars K; Bygum, Anette; Krogh, Lotte N

    2010-01-01

    Summary We present a 3-year-old boy with pigmentary mosaicism and persistent intractable infantile spasms due to mosaicism of chromosome 7. Getting the diagnosis of pigmentary mosaicism in a child with infantile spasms may not be easy, as most diagnostic work-up is done in infancy, at a time when...

  19. Iris melanocytoma.

    Science.gov (United States)

    Radovanović, Anica Bobić; Krnjaja, Bojana Dacić; Jaksić, Vesna

    2016-01-01

    Iris melanocytoma (IM) is a rare benign tumor, but unavoidable in differential diagnosis of pigmented iris lesions. According to the best knowledge of the authors it is for the first time in Serbia that a well-documented case of IM is presented and that the problem of this tumor is discussed. In the left eye of a 47-year-old white female at the iris in a six o'clock position, a highly pigmented, dome shaped lesion with a crater-like cavity in the center and with feathery margins was noticed. There were no signs of infiltration of surrounding tissue or intrinsic vessels and the lens was clear. Visual acuity and intraocular pressure were normal. An ultrasound biomicroscopy (UBM) revealed a well-defined lesion with high internal reflectivity, with a base diameter of 1.25 mm and a thickness of 0.80 mm in the periphery, and 0.53 mm in the central part.The diagnosis of IM of the left eye was established and regular checkups were performed for ten years. No changes in clinical or UBM presentation were established. Awareness of clinical presentation of IM is most important for correct diagnosis. Ultrasound biomicroscopy is a useful diagnostic procedure in the following up of IM.

  20. Posterior microphthalmos pigmentary retinopathy syndrome.

    Science.gov (United States)

    Pehere, Niranjan; Jalali, Subhadra; Deshmukh, Himanshu; Kannabiran, Chitra

    2011-04-01

    Posterior Microphthalmos Pigmentary Retinopathy Syndrome (PMPRS). Posterior microphthalmos (PM) is a relatively infrequent type of microphthalmos where posterior segment is predominantly affected with normal anterior segment measurements. Herein, we report two siblings with posterior microphthalmos retinopathy syndrome with postulated autosomal recessive mode of inheritance. A 13-year-old child had PM and retinitis pigmentosa (RP) and his 7-year-old sister had PM, RP, and foveoschisis. The genetics of this syndrome and variable phenotype is discussed. Importance of being aware of posterior microphthalmos and its posterior segment associations is highlighted.

  1. Characteristics of, prevalence of, and risk factors for corneal pigmentation (pigmentary keratopathy) in Pugs.

    Science.gov (United States)

    Labelle, Amber L; Dresser, Christine B; Hamor, Ralph E; Allender, Matthew C; Disney, Julia L

    2013-09-01

    To determine the characteristics of, prevalence of, and risk factors for corneal pigmentation (CP) in Pugs. Prospective cross-sectional study. 295 Pugs > 16 weeks old. Ophthalmic examination of the anterior segment of each eye was performed, including determination of tear film characteristics (Schirmer tear test and tear film breakup time) and corneal sensitivity. Digital photographs of the head and each eye were obtained. Corneal pigmentation of eyes was graded as absent, very mild, mild, moderate, or severe. Signalment and medical history information and American Kennel Club registration status were recorded. Results-CP was detected in at least 1 eye of 243 of the 295 (82.4%) Pugs; CP was typically very mild or mild. Detection of CP was not significantly associated with coat color, age, eyelid conformation, or tear film characteristics but was significantly associated with sex of dogs. The severity of CP was not significantly associated with American Kennel Club registration status or age, but was significantly associated with sex, tear film characteristics, and coat color. Iris hypoplasia was detected in 72.1% of the Pugs. Iris-to-iris persistent pupillary membranes were detected in 85.3% of the Pugs. Prevalence of CP in Pugs in this study was high. Unexpectedly high prevalences of iris hypoplasia and persistent pupillary membranes were also identified. The condition identified in these Pugs was a pigmentary keratopathy, rather than pigmentary keratitis or corneal melanosis. This condition may have a genetic basis, and further studies are warranted to determine etiology.

  2. Disease course of patients with unilateral pigmentary retinopathy.

    Science.gov (United States)

    Potsidis, Emorfily; Berson, Eliot L; Sandberg, Michael A

    2011-11-29

    To evaluate the change in ocular function by eye in patients with unilateral pigmentary retinopathy. Longitudinal regression was used to estimate mean exponential rates of change in Goldmann visual field area (V4e white test light) and in full-field electroretinogram (ERG) amplitudes to 0.5- and 30-Hz white flashes in 15 patients with unilateral pigmentary retinopathy. Snellen visual acuity was assessed case by case. Mean annual rates of change for the affected eyes were -4.9% for visual field area, -4.7% for ERG amplitude to 0.5-Hz flashes, and -4.6% for ERG amplitude to 30-Hz flashes. All three rates were faster than the corresponding age-related rates of change for the fellow normal eyes (P = 0.0006, P = 0.003, P = 0.03, respectively). An initial cone ERG implicit time to 30-Hz flashes in affected eyes ≥ 40 ms predicted a faster mean rate of decline of visual field area and of ERG amplitude to 0.5- and 30-Hz flashes (P 35 years of age than in patients presenting at a younger age (P = 0.0004). The affected eye in unilateral pigmentary retinopathy shows a progressive loss of peripheral retinal function that cannot be attributed to aging alone and that is faster in eyes with a more prolonged initial cone ERG implicit time. Patients presenting at >35 years of age are at greater risk for losing visual acuity.

  3. Pigment dispersion syndrome and pigmentary glaucoma: a review and update.

    Science.gov (United States)

    Scuderi, Gianluca; Contestabile, Maria Teresa; Scuderi, Luca; Librando, Aloisa; Fenicia, Vito; Rahimi, Siavash

    2018-05-02

    Potential factors influencing stereopsis were investigated in patients with both refractive accommodative esotropia (RAE) and amblyopia. Pigment dispersion syndrome (PDS) is a condition where anomalous iridozonular contact leads to pigment dispersion throughout the anterior segment and the released pigment is abnormally deposited on various ocular structures. The clinical presentation of PDS is defined by the presence of pigmented cells on the corneal endothelium, an increase of pigmentation of the trabecular meshwork, and mid-periphery transillumination defects of the iris. This syndrome, more common in myopes, is usually bilateral and can be associated with ocular hypertension or glaucoma. Secondary open-angle pigmentary glaucoma (PG) can develop due to reduction of the outflow of aqueous humour and consequent increase in intraocular pressure leading to glaucomatous optic neuropathy. Diagnosis of PG is commonly between 40 and 50 years of age, occurring more frequently in men. The advent of ultrasound biomicroscopy and anterior segment optical coherence tomography has contributed to enhancing our knowledge on the condition. Typical alterations of the anterior segment are the posterior insertion of the iris and iris concavity. Treatment of PG should be initiated early to hinder disease progression, glaucomatous damage, and vision loss. Management is based on medical therapy, laser iridotomy, selective laser trabeculoplasty, and filtration procedures. The differential diagnosis of PDS with other disorders can be challenging and awareness of the condition together with meticulous ophthalmologic examination allows early diagnosis followed by appropriate management strategies. The present review is a comprehensive report on the clinical characteristics, pathogenesis, current management, and status quo of PDS and PG.

  4. Determination Of Association Of Pigmentary Glaucoma With Pigment Dispersion Syndrome.

    Science.gov (United States)

    Shah, Imtiaz Ali; Shah, Shujaat Ali; Nagdev, Partab Rai; Abbasi, Safdar Ali; Abbasi, Naeem Ali; Katpar, Safdar Akhtar

    2017-01-01

    Pigment Dispersion Syndrome (PDS) is an autosomal dominant disorder of white males between 20 to 40 years of age characterized by deposition of pigment on the lens, zonules of lens, trabecular meshwork and corneal endothelium (Krukenberg's spindle) in addition to radial, spoke like transillumination defects in the mid peripheral iris. This study was conducted to determine the frequency of occurrence of Pigmentary Glaucoma in patients with Pigment Dispersion Syndrome (PDS). This longitudinal follow up study included patients presenting with Krukenberg's spindle on the endothelial side of cornea and pigmentation of angle of anterior chamber seen on slit lamp examination and gonioscopy. Seventy-two cases of PDS were included in the study, amongst them 63 (87.50%) were males. Mean age was 35.00±6.54 years (range 24-46 years). Forty-seven (65.28%) patients had an IOP in the range of 10-14 mmHg, 22 (30.56%) patients had an IOP in the range of 15-18 mmHg and 3 (4.17%) patients developed an IOP of greater than 19 mmHg. Fundoscopy showed myopic degeneration in 49 (68.06%) patients and optic disc cupping in 3 (4.17%) patients. Four (5.56%) patients had refractive error between +1D to +3D, 9 (12.50%) patients had refractive error between -1D to -4D, 21 (29.17%) patients had refractive error between -5 D to -8 D and 38 (52.78%) patients had refractive error between -9 D to -12 D. Our study showed that one patient having PDS developed glaucoma at 5 years of follow up and three patients developed glaucoma at 14 years of follow up. On the basis of this study we conclude that early onset primary open angle glaucoma associated with PDS or Juvenile glaucoma associated with PDS might have been mistaken as Pigmentary Glaucoma in Pakistani patients and a distinct entity in the form of Pigmentary Glaucoma may be non-existent.

  5. Retinitis pigmentosa, pigmentary retinopathies, and neurologic diseases.

    Science.gov (United States)

    Bhatti, M Tariq

    2006-09-01

    Retinitis pigmentosa (RP) refers to a group of inherited retinal diseases with phenotypic and genetic heterogeneity. The pathophysiologic basis of the progressive visual loss in patients with RP is not completely understood but is felt to be due to a primary retinal photoreceptor cell degenerative process mainly affecting the rods of the peripheral retina. In most cases RP is seen in isolation (nonsyndromic), but in some other cases it may be a part of a genetic, metabolic, or neurologic syndrome or disorder. Nyctalopia, or night blindness, is the most common symptom of RP. The classic fundus appearance of RP includes retinal pigment epithelial cell changes resulting in retinal hypo- or hyperpigmentation ("salt-and-pepper"), retinal granularity, and bone spicule formation. The retinal vessels are often narrowed or attenuated and there is a waxy pallor appearance of the optic nerve head. Electroretinography will demonstrate rod and cone photoreceptor cell dysfunction and is a helpful test in the diagnosis and monitoring of patients with RP. A detailed history with pedigree analysis, a complete ocular examination, and the appropriate paraclinical testing should be performed in patients complaining of visual difficulties at night or in dim light. This review discusses the clinical manifestations of RP as well as describing the various systemic diseases, with a special emphasis on neurologic diseases, associated with a pigmentary retinopathy.

  6. [Intraoperative floppy iris syndrome].

    Science.gov (United States)

    Mazal, Z

    2007-04-01

    In the year 2005, Chang and Cambell described unusual reaction of the iris during the cataract surgery in patients treated with tamsulosine. This was named as IFIS, an acronym for the Intraoperative Floppy Iris Syndrome. In its advanced stage, the syndrome is characterized by insufficient mydfiasis before the surgery, narrowing of the pupil during the surgery, its impossible dilatation during the surgery by means of stretching, unusual elasticity of the pupilar margin, surging and fluttering iris with tendency to prolapse. The same manifestations we observed in our patients and we confirm the direct connection with tamsulosine hydrochloride treatment. Tamsulosine is the antagonist of alpha 1A adrenergic receptors whose are present, except in the smooth musculature of the prostate gland and the urinary bladder, in the iris dilator as well. At the same time we observed this syndrome rarely in some patients not using tamsulosine. In most cases, these patients were treated with antipsychotic drugs.

  7. Ordinal measures for iris recognition.

    Science.gov (United States)

    Sun, Zhenan; Tan, Tieniu

    2009-12-01

    Images of a human iris contain rich texture information useful for identity authentication. A key and still open issue in iris recognition is how best to represent such textural information using a compact set of features (iris features). In this paper, we propose using ordinal measures for iris feature representation with the objective of characterizing qualitative relationships between iris regions rather than precise measurements of iris image structures. Such a representation may lose some image-specific information, but it achieves a good trade-off between distinctiveness and robustness. We show that ordinal measures are intrinsic features of iris patterns and largely invariant to illumination changes. Moreover, compactness and low computational complexity of ordinal measures enable highly efficient iris recognition. Ordinal measures are a general concept useful for image analysis and many variants can be derived for ordinal feature extraction. In this paper, we develop multilobe differential filters to compute ordinal measures with flexible intralobe and interlobe parameters such as location, scale, orientation, and distance. Experimental results on three public iris image databases demonstrate the effectiveness of the proposed ordinal feature models.

  8. Role of laser peripheral iridotomy in pigmentary glaucoma and pigment dispersion syndrome: A review of the literature.

    Science.gov (United States)

    Buffault, J; Leray, B; Bouillot, A; Baudouin, C; Labbé, A

    2017-11-01

    Pigment dispersion syndrome (PDS) is characterized by a structural abnormality of the posterior surface of the iris causing contact with the zonular fibers. It can lead to an open-angle glaucoma secondary to pigment dispersion into the trabecular meshwork. Laser peripheral iridotomy (PI) has been proposed as a treatment for pigmentary glaucoma (PG) and pigment dispersion syndrome (PDS) by reducing the dispersion of pigment. The goal of this review was to assess the effects of PI for PDS and PG. We included six randomized controlled trials and two cohort studies (286 eyes of 218 participants). Four trials included participants with PG, and 4 trials enrolled participants with PDS with or without elevated intraocular pressure (IOP). Among patients with PG, at an average of 9 months of follow-up, the mean difference in IOP between groups was 2.69mm Hg less in the PI group (95% CI: -6.05 to 0.67; 14 eyes). In patients with PDS, the average IOP was statistically lower after PI as compared to baseline (Student test t=11.49, P<0.01, 38 eyes). With regard to visual field progression in participants with PG, after an average follow-up of 28 months, the risk of progression was not influenced by PI (RR 1.00 95% CI: 0.16 to 6.25; 32 eyes). No trials that enrolled patients with PDS showed a diminution of the risk of glaucoma conversion at mid- and long-terms. PI decreases the biomechanical factor causing contact between the iris and zonular fibers and may lower IOP over the long-term. Nevertheless, the effects of PI on visual field changes or progression have not been established in PG and PDS. There is no scientific evidence as of yet to advocate PI as a treatment for PDS or PG. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. Disparity in Cutaneous Pigmentary Response to LED vs Halogen Incandescent Visible Light: Results from a Single Center, Investigational Clinical Trial Determining a Minimal Pigmentary Visible Light Dose.

    Science.gov (United States)

    Soleymani, Teo; Cohen, David E; Folan, Lorcan M; Okereke, Uchenna R; Elbuluk, Nada; Soter, Nicholas A

    2017-11-01

    Background: While most of the attention regarding skin pigmentation has focused on the effects of ultraviolet radiation, the cutaneous effects of visible light (400 to 700nm) are rarely reported. The purpose of this study was to investigate the cutaneous pigmentary response to pure visible light irradiation, examine the difference in response to different sources of visible light irradiation, and determine a minimal pigmentary dose of visible light irradiation in melanocompetent subjects with Fitzpatrick skin type III - VI. The study was designed as a single arm, non-blinded, split-side dual intervention study in which subjects underwent visible light irradiation using LED and halogen incandescent light sources delivered at a fluence of 0.14 Watts/cm2 with incremental dose progression from 20 J/cm2 to 320 J/cm2. Pigmentation was assessed by clinical examination, cross-polarized digital photography, and analytic colorimetry. Immediate, dose-responsive pigment darkening was seen with LED light exposure in 80% of subjects, beginning at 60 Joules. No pigmentary changes were seen with halogen incandescent light exposure at any dose in any subject. This study is the first to report a distinct difference in cutaneous pigmentary response to different sources of visible light, and the first to demonstrate cutaneous pigment darkening from visible LED light exposure. Our findings raise the concern that our increasing daily artificial light surroundings may have clandestine effects on skin biology. J Drugs Dermatol. 2017;16(11):1105-1110..

  10. Unilateral pigmentary degeneration of the retina associated with heterochromia iridis.

    Science.gov (United States)

    Grisanti, S; Diestelhorst, M; Lebek, J; Walter, P; Heimann, K

    1998-12-01

    For the past 5 years, a 56-year-old patient has been displaying monocular progressive pigmentary changes in the left eye. Heterochromy of the left eye has been known since childhood. The other eye is clinically and functionally normal. The patient was adopted and he has no children. Therefore, we have no family history. The patient was examined clinically and by means of electroretinography, electrooculography, perimetry, computer tomography, pulsatile ocular blood flow (POBF) measurement, serology and Doppler sonography. Electrophysiology displayed a considerable reduction of scotopic and photopic ERGs, a reduced dark-through, and a reduced light-rise in the left eye, whereas the fellow eye was normal. The visual field was limited to 5 deg around the fixation point, and a peripheral crescent-shaped arch encircled the temporal-inferior quadrant concomitant to the pigmentary changes. By computer tomography and Doppler sonography a vascular affection was excluded. The left eye displayed lower POBF values. All serological tests were found negative. The clinical picture and negative exclusion criteria indicate a unilateral retinitis pigmentosa. However, with regard to the literature an unequivocal diagnosis can only be made upon hereditary evidence.

  11. Pigmentary disorders in Western countries

    NARCIS (Netherlands)

    van der Veen, J. P. Wietze

    2007-01-01

    Countries in the so-called "Western" world, especially in Europe, witnessed a dramatic change in ethnic backgrounds of their populations starting in the last decennia of the last century. This had repercussions on various aspects of our society, including medical practice. In dermatology for

  12. Engineering a Light-Attenuating Artificial Iris.

    Science.gov (United States)

    Shareef, Farah J; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-04-01

    Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage.

  13. Pigment Dispersion Syndrome Progression to Pigmentary Glaucoma in a Latin American Population.

    Science.gov (United States)

    Gomez Goyeneche, Hector Fernando; Hernandez-Mendieta, Diana Patricia; Rodriguez, Diego Andres; Sepulveda, Ana Irene; Toledo, Jose Daniel

    2015-01-01

    To determine the progression of pigment dispersion syndrome (PDS) into pigmentary glaucoma (PG) in a population at the Central Military Hospital in Bogotá, Colombia. A retrospective study was conducted, based on a review of medical records of patients with PDS evaluated in the Glaucoma Clinic. Data were collected in a database in excel and subsequently analyzed with the software Statistical Package for the Social Sciences (SPSS), performing Chi-square test analysis and Spearman's rho test. Forty-eight eyes of 24 patients were included. Forty-two percent were women and 58% were men. Pigmentation of the trabecular meshwork was the most frequent clinical sign (100%), followed by Krukenberg's spindle (91.7%), the least frequent were the iris concavity and iris heterochromia (4.2%), the average of the spherical equivalent was of - 1.33 (SD 2.07). The rate of conversion of PDS to PG was 37.5%, after an average follow-up of 50.7 months. Having an intraocular pressure (IOP) greater than 21 mm Hg was statistically the only significant risk factor for conversion. We found several differences in frequency and clinical signs in these patients in contrast to previous data, probably due to different racial characteristics. The rate of progression is similar to previous reports despite of heterogeneity of these. Having IOP > 21 mm Hg was the only risk factor associated with progression in this sample. How to cite this article: Gomez Goyeneche HF, Hernandez-Mendieta DP, Rodriguez DA, Sepulveda AI, Toledo JD. Pigment Dispersion Syndrome Progression to Pigmentary Glaucoma in a Latin American Population. J Curr Glaucoma Pract 2015;9(3):69-72.

  14. Genetic Background of Iris Melanomas and Iris Melanocytic Tumors of Uncertain Malignant Potential.

    Science.gov (United States)

    van Poppelen, Natasha M; Vaarwater, Jolanda; Mudhar, Hardeep S; Sisley, Karen; Rennie, Ian G; Rundle, Paul; Brands, Tom; van den Bosch, Quincy C C; Mensink, Hanneke W; de Klein, Annelies; Kiliç, Emine; Verdijk, Robert M

    2018-01-19

    Uveal melanoma (UM) is the most common primary intraocular malignancy in adults. Iris melanoma comprises 4% to 10% of all UMs and has a lower mortality rate. The genetic changes in iris melanoma are not as well characterized as ciliary body or choroidal melanoma. The aim of this study was to gain more insight into the genetic background of iris melanoma and iris nevi. Multicenter, retrospective case series. Patients diagnosed with iris melanoma or iris nevi who underwent surgical intervention as primary or secondary treatment. Next-generation sequencing of GNAQ, GNA11, EIF1AX, SF3B1, BAP1, NRAS, BRAF, PTEN, c-Kit, TP53, and TERT was performed on 30 iris melanomas and 7 iris nevi. Copy number status was detected using single nucleotide polymorphisms (SNPs) included in the next-generation sequencing (NGS) panel, SNP array, or fluorescent in situ hybridization. BAP1 immunohistochemistry was performed on all samples. Mutation and copy number status were analyzed. Results of BAP1 immunohistochemistry were used for survival analysis. In 26 of the 30 iris melanoma and all iris nevi, at least 1 mutation was identified. Multiple mutations were detected in 23 iris melanoma and 5 nevi, as well as mutations in GNAQ and GNA11. Furthermore, 13 of 30 BAP1, 5 of 30 EIF1AX, and 2 of 30 SF3B1 mutations were identified in iris melanoma. No correlation between BAP1 status and disease-free survival was found. The iris nevi showed 1 EIF1AX and 3 BAP1 mutations. Two of the nevi, with a BAP1 mutation, were histologically borderline malignant. Mutations in NRAS, BRAF, PTEN, c-KIT, and TP53 were detected in 6 iris melanomas and 4 iris nevi. Mutations that are often found in uveal and cutaneous melanoma were identified in this cohort of iris melanomas and iris nevi. Therefore, iris melanomas harbor a molecular profile comparable to both choroidal melanoma and cutaneous melanoma. These findings may offer adjuvant targeted therapies for iris melanoma. There was no prognostic significance of

  15. Negative electroretinograms in pericentral pigmentary retinal degeneration.

    Science.gov (United States)

    Hotta, Kazuki; Kondo, Mineo; Nakamura, Makoto; Hotta, Junko; Terasaki, Hiroko; Miyake, Yozo; Hida, Tetsuo

    2006-01-01

    The clinical presentation and electrophysiological findings are described of three consecutive cases with pericentral pigmentary retinal degeneration. The responses to bright flashes after dark adaptation showed negative waveform shape in all cases. Rod responses were strongly reduced compared with cone responses. Cone electroretinograms elicited by long-duration stimuli showed greater loss of the on-response than the off-response. The ratio of the on-response amplitude to off-response amplitude of these patients (0.52 +/- 0.12; mean +/- SD, n = 6) was significantly smaller than that of normal subject (0.83 +/- 0.21; mean +/- SD, n = 8) (Mann-Whitney U-test, P retinal function, especially in transmission between photoreceptors and depolarizing bipolar cells.

  16. Acquired retinal pigmentary degeneration in a child with 13q deletion syndrome.

    Science.gov (United States)

    Aguilera, Zenia P; Belin, Peter J; Cavuoto, Kara M; Jayakar, Parul; McKeown, Craig A

    2015-10-01

    Orbeli syndrome, or 13q deletion syndrome, is a rare condition caused by a distal deletion in the long arm of chromosome 13. The syndrome is characterized by severe physical malformations and developmental delays and has been associated with numerous ocular manifestations. We report the case of a 10-year-old boy with 13q deletion syndrome, who was evaluated for impaired vision and found to have bilateral retinal pigmentary changes resembling those seen in retinitis pigmentosa. There has only been one other case of retinal pigment variation in association with 13q deletion syndrome; however, this represents the first case of bilateral symmetric retinal pigmentary changes with corresponding rod and cone dysfunction on electroretinography. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  17. [Spinocerebellar ataxia type 2 associated to pigmentary retinitis].

    Science.gov (United States)

    Jiménez-Caballero, Pedro Enrique; Serviá, Mónica

    2010-07-01

    Ocular disorders are useful in the characterisation of the different types of spinocerebellar ataxias (SCA); pigmentary retinitis is an alteration that is specifically associated to SCA type 7 and is characterised by night blindness, sensitivity to glare and progressive narrowing of the visual field. A 34-year-old woman with clinical symptoms of progressive ataxia and visual impairment secondary to pigmentary retinitis. The patient had a personal history with an autosomal dominant pattern of a similar disorder in her father and paternal grandmother. In the genetic study she presented a triplet expansion in the SCA type 2 gene. CONCLUSIONS; Although pigmentary retinitis belongs to the SCA type 7 phenotype, our patient presented this retinal disorder, as in other cases of SCA type 2. A genetic study for SCA type 2 must therefore be conducted in patients with a degenerative ataxic clinical picture and who present evidence of pigmentary retinitis.

  18. [Role of laser peripheral iridotomy in pigmentary glaucoma and pigment dispersion syndrome: A review of the literature [French version

    Science.gov (United States)

    Buffault, J; Leray, B; Bouillot, A; Baudouin, C; Labbé, A

    2017-12-01

    Pigment dispersion syndrome (PSD) is characterized by a structural abnormality of the posterior surface of the iris causing contact with the zonular fibers. It can lead to an open-angle glaucoma secondary to pigment dispersion into the trabecular meshwork. Laser peripheral iridotomy (PI) has been proposed as a treatment for pigmentary glaucoma (PG) and pigment dispersion syndrome (PDS) by reducing the dispersion of pigment. The goal of this review was to assess the effects of PI for PSD and PG. We included six randomized controlled trials and two cohort studies (286 eyes of 218 participants). Four trials included participants with PG, and 4 trials enrolled participants with PSD with or without elevated intraocular pressure (IOP). Among patients with PG, at an average of 9 months of follow-up, the mean difference in IOP between groups was 2.69mmHg less in the PI group (95 % CI: -6.05 to 0.67; 14 eyes). In patients with PDS, the average IOP was statistically lower after PI as compared to baseline (Student test, t=11.49, P<0.01). With regard to visual field progression in participants with GP, after an average follow-up of 28 months, the risk of progression was not influenced by PI (RR 1.00 95 %: CI 0.16 to 6.25; 32 eyes). No trials that enrolled patients with PSD showed a diminution of the risk of glaucoma conversion at mid- and long-term. PI decreases the biomechanical factor causing contact between the iris and zonular fibers and may lower IOP over the long-term. Nevertheless, the effects of PI on visual field changes or progression have not been established in PG and PDS. There is no scientific evidence as of yet to advocate PI as a treatment for PDS or PG. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Pigmentary retinopathy associated with the mitochondrial DNA 3243 point mutation.

    Science.gov (United States)

    Sue, C M; Mitchell, P; Crimmins, D S; Moshegov, C; Byrne, E; Morris, J G

    1997-10-01

    Fourteen patients from four unrelated families were studied to determine the prevalence of retinal pigmentary abnormalities associated with the MELAS A to G 3243 point mutation. Neurologic and ophthalmic examinations, retinal photography, pattern shift visual evoked potentials, and electroretinography were performed in all patients. Eight of the 14 patients had retinal pigmentary abnormalities characterized by symmetric areas of depigmentation involving predominantly the posterior pole and midperipheral retina. None of the patients had optic atrophy and only one patient with pigmentary retinal abnormalities had impaired visual acuity. None of the diabetic subjects (n = 6) had signs of diabetic retinopathy. Fluorescein angiography demonstrated mottled hyper- and hypofluorescent areas indicating multiple window defects in the retinal pigmentary epithelium. Visual evoked potentials showed delayed P100 responses in four of the eight patients with retinal pigmentary abnormalities. We conclude that there is a high prevalence of retinal pigmentary abnormalities in patients with MELAS A to G 3243 point mutation. These abnormalities are usually asymptomatic and best detected by retinal photography.

  20. The IRIS user guide

    International Nuclear Information System (INIS)

    Adams, M.; Howells, W.; Telling, M.

    2001-01-01

    The principles of operation of the IRIS instrument based on inelastic neutron scattering and diffraction are described. The procedure of an experiment performance on IRIS consists of selecting sample cans, loading the sample into the neutron beam. Instructions for using the beam line shutter interlock system, IRIS computing procedure, suitable instrument settings and chopper control are included

  1. Petaloid-pattern pigmentary retinopathy: a novel case report.

    Science.gov (United States)

    Padhi, Tapas Ranjan; Jalali, Subhadra; Panda, Krushna Gopal; Mukherjee, Sujoy; Mohan, Neha; Agroiya, Pushpalata; Das, Taraprasad

    2014-10-01

    We report the case of a 6-year-old girl with an unusual petaloid-pattern pigmentary retinopathy associated with nyctalopia and reduction of vision which had been invariably static over the past 5 years. We performed a comprehensive ophthalmic examination including fundoscopy, autofluorescent imaging, electroretinography and optical coherence tomography. There were diffuse retinal pigment epithelium (RPE) washout areas with blotches of pigment distributed in the pattern of a petal with marked chorioretinal atrophy and scar at the fovea. The arterial caliber was normal. Investigations ruled out intrauterine and neonatal infection. Systemically, she was healthy with normal intellect but with 3-month delayed milestones of development. She had used valproic acid for seizure disorder (without any organic central nervous system lesion) from 2-5 years of age. Electroretinography showed extinguished scotopic responses with slight reduction in cone responses. Optical coherence tomography showed a scar with attenuated RPE-choriocapillary complex at the macula. Her clinical profile did not fully match with any previously described pigmentary retinopathies except rod-cone dystrophy and choroidal dystrophy to a certain extent. The pigmentary retinopathy reported here is a combination of a petaloid pattern of pigmentary disturbance, stationary reduction of vision, nyctalopia, normal intellect and marginal delayed milestones. In the absence of such a description in the literature we named this disorder as petaloid-pattern pigmentary retinopathy.

  2. Engineering a Light-Attenuating Artificial Iris

    Science.gov (United States)

    Shareef, Farah J.; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-01-01

    Purpose Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. Methods The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Results Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Conclusions Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage. PMID:27116547

  3. A Patient with Keratoconus, Nanophthalmos, Lipodermoids, and Pigmentary Retinopathy.

    Science.gov (United States)

    Sammouh, Fady K; Baban, Tania A; Warrak, Elias L

    2016-06-01

    A 44-year-old male with no pertinent history other than poor vision for more than 25 years was examined. Best corrected visual acuity was 20/80 OD [MR: +14.25 +1.00 × 15°] and 20/200 OS [MR: +15.00 +1.50 × 175°]. Significant limitation in ocular movements and the presence of an orbital lipodermoid in the infero-temporal aspect of each eye were noted. Forced duction test was positive for the same directions of limitation indicating possible extraocular muscle fibrosis. Ophthalmoscopy was remarkable for the presence of peripheral bony spicules. Corneal topography was compatible with keratoconus (Kmax = 55.04D OD and 52.87D OS). A-scan revealed axial lengths of 16.96 mm OD and 16.32 mm OS, compatible with a diagnosis of nanophthalmos. OCT revealed diffuse macular thickening for both eyes with foveal thickness of 350 µm OD and 353 µm OS. Over the next 12 years the patient had stable visual acuity, manifest refractions and anterior segment examination. Ophthalmoscopy revealed only minimal progression of pigmentary changes. We report the first case of these simultaneous multiple findings which may refer to a possible syndromic association of congenital or early childhood onset.

  4. Iris Recognition Using Wavelet

    Directory of Open Access Journals (Sweden)

    Khaliq Masood

    2013-08-01

    Full Text Available Biometric systems are getting more attention in the present era. Iris recognition is one of the most secure and authentic among the other biometrics and this field demands more authentic, reliable and fast algorithms to implement these biometric systems in real time. In this paper, an efficient localization technique is presented to identify pupil and iris boundaries using histogram of the iris image. Two small portions of iris have been used for polar transformation to reduce computational time and to increase the efficiency of the system. Wavelet transform is used for feature vector generation. Rotation of iris is compensated without shifts in the iris code. System is tested on Multimedia University Iris Database and results show that proposed system has encouraging performance.

  5. Bilateral nanophthalmos and pigmentary retinal dystrophy--an unusual syndrome.

    Science.gov (United States)

    Proença, Helena; Castanheira-Dinis, A; Monteiro-Grillo, M

    2006-09-01

    To report the clinical picture of the rare association of nanophthalmos and pigmentary retinal dystrophy and its cataract surgery outcome. We report a case of a 60-year-old female who presented with bilateral slowly progressive visual loss. The patient presented with bilateral light perception visual acuity, exotropia, brunescent cataract hindering fundus examination and hypodontia. Ultrasonography revealed bilateral nanophthalmos. A visual-evoked potential was also performed preoperatively. Cataract surgery with +40D IOL implantation was uneventful. Postoperative fundus examination revealed pigmentary retinal dystrophy, confirmed by electrophysiologic tests. Glycosaminoglycan urinary excretion was normal. Congenital bilateral nanophthalmos may rarely be associated with pigmentary retinal dystrophy. We suggest thorough preoperative evaluation in nanophthalmic eyes for the exclusion of significant features concerning visual prognosis.

  6. Feature Vector Construction Method for IRIS Recognition

    Science.gov (United States)

    Odinokikh, G.; Fartukov, A.; Korobkin, M.; Yoo, J.

    2017-05-01

    One of the basic stages of iris recognition pipeline is iris feature vector construction procedure. The procedure represents the extraction of iris texture information relevant to its subsequent comparison. Thorough investigation of feature vectors obtained from iris showed that not all the vector elements are equally relevant. There are two characteristics which determine the vector element utility: fragility and discriminability. Conventional iris feature extraction methods consider the concept of fragility as the feature vector instability without respect to the nature of such instability appearance. This work separates sources of the instability into natural and encodinginduced which helps deeply investigate each source of instability independently. According to the separation concept, a novel approach of iris feature vector construction is proposed. The approach consists of two steps: iris feature extraction using Gabor filtering with optimal parameters and quantization with separated preliminary optimized fragility thresholds. The proposed method has been tested on two different datasets of iris images captured under changing environmental conditions. The testing results show that the proposed method surpasses all the methods considered as a prior art by recognition accuracy on both datasets.

  7. Waardenburg syndrome: iris and choroidal hypopigmentation: findings on anterior and posterior segment imaging.

    Science.gov (United States)

    Shields, Carol L; Nickerson, Stephanie J; Al-Dahmash, Saad; Shields, Jerry A

    2013-09-01

    Waardenburg syndrome typically manifests with congenital iris pigmentary abnormalities, but careful inspection can reveal additional posterior uveal pigmentary abnormalities. To demonstrate iris and choroidal hypopigmentation in patients with Waardenburg syndrome. Retrospective review of 7 patients referred for evaluation of presumed ocular melanocytosis. To describe the clinical and imaging features of the anterior and posterior uvea. In all patients, the diagnosis of Waardenburg syndrome was established. The nonocular features included white forelock in 4 of 7 (57%), tubular nose in 5 of 6 (83%), and small nasal alae in 5 of 6 (83%) patients. In 2 patients, a hearing deficit was documented on audiology testing. Family history of Waardenburg syndrome was elicited in 5 of 7 (71%) patients. Ocular features (7 patients) included telecanthus in 5 (71%), synophrys in 2 (29%), iris hypopigmentation in 5 (71%), and choroidal hypopigmentation in 5 (71%) patients. No patient had muscle contractures or Hirschsprung disease. Visual acuity was 20/20 to 20/50 in all patients. Iris hypopigmentation in 8 eyes was sector in 6 (75%) and diffuse (complete) in 2 (25%). Choroidal hypopigmentation in 9 eyes (100%) showed a sector pattern in 6 (67%) and a diffuse pattern in 3 (33%). Anterior segment optical coherence tomography revealed the hypopigmented iris to be thinner and with shallower crypts than the normal iris. Posterior segment optical coherence tomography showed a normal retina in all patients, but the subfoveal choroid in the hypopigmented region was slightly thinner (mean, 197 μm) compared with the opposite normal choroid (243 μm). Fundus autofluorescence demonstrated mild hyperautofluorescence (scleral unmasking) in hypopigmented choroid and no lipofuscin abnormality. Waardenburg syndrome manifests hypopigmentation of the iris and choroid with imaging features showing a slight reduction in the thickness of the affected tissue.

  8. Double heterozygous mutations of MITF and PAX3 result in Waardenburg syndrome with increased penetrance in pigmentary defects.

    Science.gov (United States)

    Yang, T; Li, X; Huang, Q; Li, L; Chai, Y; Sun, L; Wang, X; Zhu, Y; Wang, Z; Huang, Z; Li, Y; Wu, H

    2013-01-01

    Waardenburg syndrome (WS) is characterized by sensorineural hearing loss and pigmentary defects of the hair, skin, and iris. Heterozygous mutations of MITF and its transactivator gene PAX3 are associated with Waardenburg syndrome type II (WS2) and type I (WS1), respectively. Most patients with MITF or PAX3 mutations, however, show variable penetrance of WS-associated phenotypes even within families segregating the same mutation, possibly mediated by genetic background or specific modifiers. In this study, we reported a rare Waardenburg syndrome simplex family in which a pair of WS parents gave birth to a child with double heterozygous mutations of MITF and PAX3. Compared to his parents who carried a single mutation in either MITF or PAX3, this child showed increased penetrance of pigmentary defects including white forelock, white eyebrows and eyelashes, and patchy facial depigmentation. This observation suggested that the expression level of MITF is closely correlated to the penetrance of WS, and variants in transcription regulator genes of MITF may modify the relevant clinical phenotypes. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  9. Iridium Interfacial Stack (IRIS)

    Science.gov (United States)

    Spry, David James (Inventor)

    2015-01-01

    An iridium interfacial stack ("IrIS") and a method for producing the same are provided. The IrIS may include ordered layers of TaSi.sub.2, platinum, iridium, and platinum, and may be placed on top of a titanium layer and a silicon carbide layer. The IrIS may prevent, reduce, or mitigate against diffusion of elements such as oxygen, platinum, and gold through at least some of its layers.

  10. TAPIOCA MELANOMA OF THE IRIS

    NARCIS (Netherlands)

    DEKEIZER, RJW; OOSTERHUIS, JA; HOUTMAN, WA; DEWOLFFROUENDAAL, D

    Clinical identification of tapioca melanoma of the iris is important because its medical treatment may differ from that of other malignant iris melanomas. The characteristic iris nodules must be differentiated from granulomatous uveitis, metastases, and Lisch nodules (neurofibromatosis). We will

  11. Edge detection techniques for iris recognition system

    International Nuclear Information System (INIS)

    Tania, U T; Motakabber, S M A; Ibrahimy, M I

    2013-01-01

    Nowadays security and authentication are the major parts of our daily life. Iris is one of the most reliable organ or part of human body which can be used for identification and authentication purpose. To develop an iris authentication algorithm for personal identification, this paper examines two edge detection techniques for iris recognition system. Between the Sobel and the Canny edge detection techniques, the experimental result shows that the Canny's technique has better ability to detect points in a digital image where image gray level changes even at slow rate

  12. The concave iris in pigment dispersion syndrome.

    Science.gov (United States)

    Liu, Lance; Ong, Ee Lin; Crowston, Jonathan

    2011-01-01

    To visualize the changes of the iris contour in patients with pigment dispersion syndrome after blinking, accommodation, and pharmacologic miosis using anterior segment optical coherence tomography. Observational case series. A total of 33 eyes of 20 patients with pigment dispersion syndrome. Each eye was imaged along the horizontal 0- to 180-degree meridian using the Visante Anterior Segment Imaging System (Carl Zeiss Meditec, Dublin, CA). Scans were performed at baseline and after focusing on an internal fixation target for 5 minutes, forced blinking, accommodation, and pharmacologic miosis with pilocarpine 2%. Quantitative analysis of the changes in the iris configuration. After 5 minutes of continual fixation, the iris became planar with the mean ± standard deviation curvature decreasing from 214 ± 74 μm to 67 ± 76 μm (P pigment dispersion syndrome after forced blinking, but the iris concavity recovered to 227 ± 113 μm (P = 0.34) and 238 ± 119 μm (P = 0.19) with the -3.0 and -6.0 diopter lenses, respectively. Pilocarpine-induced miosis caused the iris to assume a planar configuration in all subjects. This study shows that the iris in pigment dispersion syndrome assumes a planar configuration when fixating and that the concavity of the iris surface is not restored by blinking. Accommodation restored the iris concavity, suggesting that the posterior curvature of the iris in pigment dispersion syndrome is induced and probably maintained, at least in part, by accommodation. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  13. Pigment dispersion syndrome and pigmentary glaucoma after secondary sulcus transscleral fixation of single-piece foldable posterior chamber intraocular lenses in Chinese aphakic patients.

    Science.gov (United States)

    Tong, Nianting; Liu, Fuling; Zhang, Ting; Wang, Liangyu; Zhou, Zhanyu; Gong, Huimin; Yuan, Fuxiang

    2017-05-01

    To describe secondary pigment dispersion syndrome (PDS) and pigmentary glaucoma after secondary sulcus transscleral fixation of 1-piece hydrophobic acrylic foldable posterior chamber intraocular lenses (PC IOLs) in aphakic patients in a Chinese population. Department of Ophthalmology, Qingdao Municipal Hospital, Qingdao, China. Retrospective case series. This chart review included eyes that had secondary sulcus transscleral fixation of a 1-piece hydrophobic acrylic foldable PC IOL (Tecnis ZCB00) between March 2011 and March 2014. The patients' demographic data, clinical data, postoperative complications, intervals between initial surgery and the onset of PDS, pigmentary glaucoma occurrences, and findings on slitlamp biomicroscopy, gonioscopy, and ultrasound biomicroscopy (UBM) were recorded. The study comprised 23 consecutive eyes of 21 patients. Seventeen eyes of 16 patients were diagnosed with PDS, and 7 eyes of 6 patients were diagnosed with pigmentary glaucoma. The slitlamp examination and UBM showed that the location between the IOL optic and the posterior surface of the iris was very close. Slitlamp examination of the anterior chamber angle using a gonioscope showed dense pigment deposition on the IOL surfaces. A reverse pupillary block was found in 10 eyes of 9 patients. Other postoperative complications included intraocular hemorrhage, pupillary capture of the IOL optic, IOL tilt, IOL decentration, IOL dislocation, and suture erosion. The 1-piece hydrophobic acrylic foldable PC IOL was not suitable for sulcus transscleral fixation because of a high incidence of PDS and pigmentary glaucoma after surgery in a Chinese population. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. IRIS Licensing Status

    International Nuclear Information System (INIS)

    Kling, Charles L.; Carelli, Mario D.

    2006-01-01

    The International Reactor Innovative and Secure (IRIS) nuclear power plant is well into the pre-application review process with the US NRC and has accomplished its first near term goal of obtaining US NRC feedback on the long term testing program. To date, the IRIS team has submitted to the US NRC a number of documents patterned after the Evaluation Model Development and Assessment Process (EMDAP) outlined in Regulatory Guide 1,203. They have covered a detailed description of IRIS, initial safety analysis results, PIRT development for limiting transients, scaling analysis and a description of the test program. The IRIS Safety-by-Desing TM intrinsically eliminates and/or significantly reduces the consequences of traditional LWR accidents. In addition, the fewer passive safety systems are similar in principle to those of the US NRC approved AP1000 design. For these reasons, the IRIS testing program only needs to include those features unique to the IRIS design. NRC feedback was that the planned test program appeared to be complete and could generate sufficient information to support a Design Certification (DC) submittal. The US NRC has also stated that a DC application must include complete information regarding the test program. On this basis the IRIS team has initiated an aggressive program to conduct IRIS testing to support a DC submittal by the end of 2008. Subsequent US NRC review should be expeditious because of the AP1000 precedent, allowing IRIS to obtain its Final Design Approval (FDA) in 2012; thereby, maintaining its goal of deployment in the 2015-2017 time frame. The next steps in the pre-application review process will be to provide the US NRC with a road map of the anticipated IRIS licensing process, a review of current licensing requirements showing that IRIS meets or exceeds all current criteria and information to support the long term goal of redefining the Emergency Planning Zone (EPZ)

  15. Iris and periocular biometrics

    CERN Document Server

    Rathgeb, Christian

    2017-01-01

    This book provides an overview of scientific fundamentals and principles of iris and periocular biometric recognition. It covers: an introduction to iris and periocular recognition; a selective overview of issues and challenges; soft biometric classification; security aspects; privacy protection and forensics; and future trends.

  16. Precise colocalization of interacting structural and pigmentary elements generates extensive color pattern variation in Phelsuma lizards

    Science.gov (United States)

    2013-01-01

    Background Color traits in animals play crucial roles in thermoregulation, photoprotection, camouflage, and visual communication, and are amenable to objective quantification and modeling. However, the extensive variation in non-melanic pigments and structural colors in squamate reptiles has been largely disregarded. Here, we used an integrated approach to investigate the morphological basis and physical mechanisms generating variation in color traits in tropical day geckos of the genus Phelsuma. Results Combining histology, optics, mass spectrometry, and UV and Raman spectroscopy, we found that the extensive variation in color patterns within and among Phelsuma species is generated by complex interactions between, on the one hand, chromatophores containing yellow/red pteridine pigments and, on the other hand, iridophores producing structural color by constructive interference of light with guanine nanocrystals. More specifically, we show that 1) the hue of the vivid dorsolateral skin is modulated both by variation in geometry of structural, highly ordered narrowband reflectors, and by the presence of yellow pigments, and 2) that the reflectivity of the white belly and of dorsolateral pigmentary red marks, is increased by underlying structural disorganized broadband reflectors. Most importantly, these interactions require precise colocalization of yellow and red chromatophores with different types of iridophores, characterized by ordered and disordered nanocrystals, respectively. We validated these results through numerical simulations combining pigmentary components with a multilayer interferential optical model. Finally, we show that melanophores form dark lateral patterns but do not significantly contribute to variation in blue/green or red coloration, and that changes in the pH or redox state of pigments provide yet another source of color variation in squamates. Conclusions Precisely colocalized interacting pigmentary and structural elements generate extensive

  17. Eye changes induced by radium

    International Nuclear Information System (INIS)

    Taylor, G.N.; Lloyd, R.D.; Shabestari, L.; Angus, W.; Muggenburg, B.A.

    1989-01-01

    Radium-induced intraocular neoplasia has not been reported in people, nor were the intraocular pigmentary changes observed in the beagles described in the dial painters or the radium 226 iatrogenic cases. However, Spiess (1969) has observed a 25% incidence of multiple pigmented naevi in the iris of the radium 224 German cases and Stefani, Spiess and Mays (1986) have noted an abnormal incidence of cataracts in this same group of patients. The reasons for the absence of the much less severe radium-induced eye changes in man as compared to the dog has not been determined. Reference is also made to the authors radium 226 rodent studies with mouse strain onychomys leucogaster. (author)

  18. Iris recognition as a biometric method after cataract surgery.

    Science.gov (United States)

    Roizenblatt, Roberto; Schor, Paulo; Dante, Fabio; Roizenblatt, Jaime; Belfort, Rubens

    2004-01-28

    Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical) distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure.

  19. Iris recognition as a biometric method after cataract surgery

    Directory of Open Access Journals (Sweden)

    Roizenblatt Jaime

    2004-01-01

    Full Text Available Abstract Background Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Methods Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. Results A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Conclusions Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure.

  20. IS (Iris Security)

    OpenAIRE

    Iovane, G.; Tortoriello, F. S.

    2003-01-01

    In the paper will be presented a safety system based on iridology. The results suggest a new scenario where the security problem in supervised and unsupervised areas can be treat with the present system and the iris image recognition.

  1. A Novel Iris Segmentation Scheme

    Directory of Open Access Journals (Sweden)

    Chen-Chung Liu

    2014-01-01

    Full Text Available One of the key steps in the iris recognition system is the accurate iris segmentation from its surrounding noises including pupil, sclera, eyelashes, and eyebrows of a captured eye-image. This paper presents a novel iris segmentation scheme which utilizes the orientation matching transform to outline the outer and inner iris boundaries initially. It then employs Delogne-Kåsa circle fitting (instead of the traditional Hough transform to further eliminate the outlier points to extract a more precise iris area from an eye-image. In the extracted iris region, the proposed scheme further utilizes the differences in the intensity and positional characteristics of the iris, eyelid, and eyelashes to detect and delete these noises. The scheme is then applied on iris image database, UBIRIS.v1. The experimental results show that the presented scheme provides a more effective and efficient iris segmentation than other conventional methods.

  2. A gallery approach for off-angle iris recognition

    Science.gov (United States)

    Karakaya, Mahmut; Yoldash, Rashiduddin; Boehnen, Christopher

    2015-05-01

    It has been proven that hamming distance score between frontal and off-angle iris images of same eye differs in iris recognition system. The distinction of hamming distance score is caused by many factors such as image acquisition angle, occlusion, pupil dilation, and limbus effect. In this paper, we first study the effect of the angle variations between iris plane and the image acquisition systems. We present how hamming distance changes for different off-angle iris images even if they are coming from the same iris. We observe that increment in acquisition angle of compared iris images causes the increment in hamming distance. Second, we propose a new technique in off-angle iris recognition system that includes creating a gallery of different off-angle iris images (such as, 0, 10, 20, 30, 40, and 50 degrees) and comparing each probe image with these gallery images. We will show the accuracy of the gallery approach for off-angle iris recognition.

  3. Primary iris leiomyoma.

    Science.gov (United States)

    Yeaney, Gabrielle A; Platt, Sean; Singh, Arun D

    Intraocular leiomyomas are uncommon and usually occur in the ciliary body. Primary leiomyoma of the iris is both rare and a difficult diagnosis to make, given melanocytic tumors are more common and may be amelanotic. The somewhat controversial diagnosis of iris leiomyoma requires further confirmation by immunohistochemistry and electron microscopy. Herein, we describe a 58-year-old man with a 2-mm round translucent pink lesion of the iris. The tumor was excised by sector iridectomy. Immunohistochemistry showed positivity for both smooth muscle actin and desmin and negativity for S-100, HMB45, SOX10, MelanA, CD31, CD34, and h-caldesmon. Epstein-Barr virus-associated smooth muscle tumor was excluded by chromogenic in situ hybridization-Epstein-Barr virus-encoded RNA. Ultrastructural analysis showed cytoplasmic myofilaments with focal fusiform densities and micropinocytotic vesicles. Our review of previous literature confirmed the unusual nature of this tumor. Primary iris leiomyoma should be considered in the differential of an amelanotic S-100-immunonegative iris tumor. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. The genetics of pigment dispersion syndrome and pigmentary glaucoma.

    Science.gov (United States)

    Lascaratos, Gerassimos; Shah, Ameet; Garway-Heath, David F

    2013-01-01

    We review the inheritance patterns and recent genetic advances in the study of pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG). Both conditions may result from combinations of mutations in more than one gene or from common variants in many genes, each contributing small effects. We discuss the currently known genetic loci that may be related with PDS/PG in humans, the role of animal models in expanding our understanding of the genetic basis of PDS, the genetic factors underlying the risk for conversion from PDS to PG and the relationship between genetic and environmental--as well as anatomical--risk factors. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Iris autofluorescence in Fuchs' heterochromic uveitis.

    Science.gov (United States)

    Liu, Qian; Jia, Yading; Zhang, Suhua; Xie, Juan; Chang, Xin; Hou, Jia; Li, Gaiyun; Koch, Douglas D; Wang, Li

    2016-10-01

    To explore the characteristic autofluorescence patterns of iris depigmentation in eyes diagnosed with Fuchs' heterochromic uveitis (FHU). Near-infrared autofluorescence images and colour images of iris were taken in 21 eyes of 21 patients with FHU, 30 eyes of 15 normal subjects, 30 eyes of 15 normal age-related iris atrophy and 33 eyes of 20 patients with uveitis other than FHU. The confocal scanning laser ophthalmoscope (Heidelberg Retina Angiograph 2, HRA2) was used for melanin-related autofluorescence imaging. The indocyanine green angiography mode of HRA2 was applied for near-infrared laser imaging, and the wavelength of the excitation laser was 795 nm. Iris colour images were also taken with the slit lamp. In normal iris, moderately intense autofluorescence was noted for the pigment ruff at the pupillary border, the crests in the pupillary zone and the collarette; and there was mild autofluorescence in the ciliary zone. In eyes with age-related iris atrophy and uveitis, much less autofluorescence was seen than the healthy normal irides. In eyes with FHU, there was moderate but discontinuous autofluorescence in the pigment ruff, a petaloid pattern of autofluorescence in the pupillary zone, moderate autofluorescence in the collarette and reticular pattern of autofluorescence in the ciliary zone. Characteristic autofluorescence patterns appeared in eyes diagnosed with FHU. Near-infrared autofluorescence is a promising objective technique to document the iris changes in FHU. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Iris - nimi marmortahvlilt / Tiit Tuumalu

    Index Scriptorium Estoniae

    Tuumalu, Tiit, 1971-

    2003-01-01

    Briti kirjanikust Iris Murdochist pajatava inglise-ameerika mängufilmist "Iris" eesti videolevisse jõudmise puhul. Võrreldakse inglise teatrilavastaja Richard Eyre filmidebüüti Elmo Nüganeni debüütfilmiga "Nimed marmortahvlil"

  7. Iris reactor development

    International Nuclear Information System (INIS)

    Paramonov, D.V.; Carelli, M.D.; Miller, K.; Lombardi, C.V.; Ricotti, M.E.; Todreas, N.E.; Greenspan, E.; Yamamoto, K.; Nagano, A.; Ninokata, H.; Robertson, J.; Oriolo, F.

    2001-01-01

    The development progress of the IRIS (International Reactor Innovative and Secure) nuclear power system is presented. IRIS is currently being developed by an international consortium of industry, laboratory, university and utility establishments, led by Westinghouse. It is aimed at achieving the four major objectives of the Generation IV nuclear systems, i.e., proliferation resistance, enhanced safety, economic competitiveness and reduced waste. The project first year activities, which are summarized here, were focused on core neutronics, in-vessel configuration, steam generator and containment design, safety approach and economic performance. Details of these studies are provided in parallel papers in these proceedings. (author)

  8. The Asian dermatologic patient: review of common pigmentary disorders and cutaneous diseases.

    Science.gov (United States)

    Ho, Stephanie G Y; Chan, Henry H L

    2009-01-01

    The Asian patient with Fitzpatrick skin types III-V is rarely highlighted in publications on cutaneous disorders or cutaneous laser surgery. However, with changing demographics, Asians will become an increasingly important group in this context. Although high melanin content confers better photoprotection, photodamage in the form of pigmentary disorders is common. Melasma, freckles, and lentigines are the epidermal disorders commonly seen, whilst nevus of Ota and acquired bilateral nevus of Ota-like macules are common dermal pigmentary disorders. Post-inflammatory hyperpigmentation (PIH) occurring after cutaneous injury remains a hallmark of skin of color. With increasing use of lasers and light sources in Asians, prevention and management of PIH is of great research interest. Bleaching agents, chemical peels, intense pulsed light (IPL) treatments, and fractional skin resurfacing have all been used with some success for the management of melasma. Q-switched (QS) lasers are effective for the management of epidermal pigmentation but are associated with a high risk of PIH. Long-pulsed neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers and IPL sources pose less of a PIH risk but require a greater number of treatment sessions. Dermal pigmentary disorders are better targeted by QS ruby, QS alexandrite, and QS 1064-nm Nd:YAG lasers, but hyper- and hypopigmentation may occur. Non-ablative skin rejuvenation using a combination approach with different lasers and light sources in conjunction with cooling devices allows different skin chromophores to be targeted and optimal results to be achieved, even in skin of color. Deep-tissue heating using radiofrequency and infra-red light sources affects the deep dermis and achieves enhanced skin tightening, resulting in eyebrow elevation, rhytide reduction, and contouring of the lower face and jawline. For management of severe degrees of photoaging, fractional resurfacing is useful for wrinkle and pigment reduction, as well as

  9. Toward accurate and fast iris segmentation for iris biometrics.

    Science.gov (United States)

    He, Zhaofeng; Tan, Tieniu; Sun, Zhenan; Qiu, Xianchao

    2009-09-01

    Iris segmentation is an essential module in iris recognition because it defines the effective image region used for subsequent processing such as feature extraction. Traditional iris segmentation methods often involve an exhaustive search of a large parameter space, which is time consuming and sensitive to noise. To address these problems, this paper presents a novel algorithm for accurate and fast iris segmentation. After efficient reflection removal, an Adaboost-cascade iris detector is first built to extract a rough position of the iris center. Edge points of iris boundaries are then detected, and an elastic model named pulling and pushing is established. Under this model, the center and radius of the circular iris boundaries are iteratively refined in a way driven by the restoring forces of Hooke's law. Furthermore, a smoothing spline-based edge fitting scheme is presented to deal with noncircular iris boundaries. After that, eyelids are localized via edge detection followed by curve fitting. The novelty here is the adoption of a rank filter for noise elimination and a histogram filter for tackling the shape irregularity of eyelids. Finally, eyelashes and shadows are detected via a learned prediction model. This model provides an adaptive threshold for eyelash and shadow detection by analyzing the intensity distributions of different iris regions. Experimental results on three challenging iris image databases demonstrate that the proposed algorithm outperforms state-of-the-art methods in both accuracy and speed.

  10. Iris-based medical analysis by geometric deformation features.

    Science.gov (United States)

    Ma, Lin; Zhang, D; Li, Naimin; Cai, Yan; Zuo, Wangmeng; Wang, Kuanguan

    2013-01-01

    Iris analysis studies the relationship between human health and changes in the anatomy of the iris. Apart from the fact that iris recognition focuses on modeling the overall structure of the iris, iris diagnosis emphasizes the detecting and analyzing of local variations in the characteristics of irises. This paper focuses on studying the geometrical structure changes in irises that are caused by gastrointestinal diseases, and on measuring the observable deformations in the geometrical structures of irises that are related to roundness, diameter and other geometric forms of the pupil and the collarette. Pupil and collarette based features are defined and extracted. A series of experiments are implemented on our experimental pathological iris database, including manual clustering of both normal and pathological iris images, manual classification by non-specialists, manual classification by individuals with a medical background, classification ability verification for the proposed features, and disease recognition by applying the proposed features. The results prove the effectiveness and clinical diagnostic significance of the proposed features and a reliable recognition performance for automatic disease diagnosis. Our research results offer a novel systematic perspective for iridology studies and promote the progress of both theoretical and practical work in iris diagnosis.

  11. Using crypts as iris minutiae

    Science.gov (United States)

    Shen, Feng; Flynn, Patrick J.

    2013-05-01

    Iris recognition is one of the most reliable biometric technologies for identity recognition and verification, but it has not been used in a forensic context because the representation and matching of iris features are not straightforward for traditional iris recognition techniques. In this paper we concentrate on the iris crypt as a visible feature used to represent the characteristics of irises in a similar way to fingerprint minutiae. The matching of crypts is based on their appearances and locations. The number of matching crypt pairs found between two irises can be used for identity verification and the convenience of manual inspection makes iris crypts a potential candidate for forensic applications.

  12. IRIS Simplified LERF Model

    International Nuclear Information System (INIS)

    Maioli, A.; Finnicum, D.J.; Kumagai, Y.

    2004-01-01

    Westinghouse is currently conducting the pre-application licensing of the International Reactor Innovative and Secure (IRIS). One of the key aspects of the IRIS design is its safety-by-designTM philosophy and within this framework the PRA is being used as an integral part of the design process. The most ambitious risk-related goal for IRIS is to reduce the Emergency Planning Zone (EPZ) to within the exclusion area by demonstrating that the off-site doses are consistent with the US Protective Action Guidelines (PAGs) for initiation of emergency response so that the required protective actions would be limited to the exclusion area. As a first step, a model has been developed to provide a first order approximation of the Large Early Release Frequency (LERF) as a surrogate predictor of the off-site doses. A key-aspect of the LERF model development is the characterization of the possible paths of release. Four main categories have been historically pointed out: (1) Core Damage (CD ) sequences with containment bypass, (2) CD sequences with containment isolation failure, (3) CD sequences with containment failure at low pressure and (4) CD sequences with containment failure at high pressure. They have been reevaluated to account for the IRIS design features

  13. Iris metastasis of gastric adenocarcinoma.

    Science.gov (United States)

    Celebi, Ali Riza Cenk; Kilavuzoglu, Ayse Ebru; Altiparmak, U Emrah; Cosar, C Banu; Ozkiris, Abdullah

    2016-03-08

    Iris metastasis in patients with gastric cancer is extremely rare. Herein, it is aimed to report on a patient with gastric adenocarcinoma and iris metastasis. A 65-year-old patient with the history of gastric cancer was admitted for eye pain and eye redness on his left eye. There was ciliary injection, severe +4 cells with hypopyon in the anterior chamber and a solitary, friable, yellow-white, fleshy-creamy vascularized 2 mm × 4 mm mass on the upper nasal part of the iris within the left eye. The presented patient's mass lesion in the iris fulfilled the criteria of the metastatic iris lesion's appearance. The ocular metastasis occurred during chemotherapy. Iris metastasis can masquerade as iridocyclitis with pseudohypopyon or glaucoma. In patients with a history of gastric cancer that present with an iris mass, uveitis, and high intraocular pressure, ocular metastasis of gastric cancer should be a consideration.

  14. IRI STORM validation over Europe

    Science.gov (United States)

    Haralambous, Haris; Vryonides, Photos; Demetrescu, Crişan; Dobrică, Venera; Maris, Georgeta; Ionescu, Diana

    2014-05-01

    The International Reference Ionosphere (IRI) model includes an empirical Storm-Time Ionospheric Correction Model (STORM) extension to account for storm-time changes of the F layer peak electron density (NmF2) during increased geomagnetic activity. This model extension is driven by past history values of the geomagnetic index ap (The magnetic index applied is the integral of ap over the previous 33 hours with a weighting function deduced from physically based modeling) and it adjusts the quiet-time F layer peak electron density (NmF2) to account for storm-time changes in the ionosphere. In this investigation manually scaled hourly values of NmF2 measured during the main and recovery phases of selected storms for the maximum solar activity period of the current solar cycle are compared with the predicted IRI-2012 NmF2 over European ionospheric stations using the STORM model option. Based on the comparison a subsequent performance evaluation of the STORM option during this period is quantified.

  15. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients.

    Science.gov (United States)

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-03-01

    To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.

  16. Color del iris e hipoacusia en el Síndrome de Waardenburg. Pinar del Río, Cuba Color of the iris and hypoacusis in Waardenburg Syndrome. Pinar del Rio, Cuba

    Directory of Open Access Journals (Sweden)

    Fidel Castro Pérez

    2012-06-01

    Full Text Available Introducción: Aunque se han descrito hipoacusia neurosensorial y cambios de color en el iris, la relación entre estos no ha sido estudiada previamente. Objetivos: Describir y analizar la posible asociación de la hipoacusia y profundidad de ésta con el color del iris en una familia afectada con el síndrome, lo que constituiría un nuevo aporte al conocimiento del Síndrome de Waardenburg (SW. Material y Método: Se realizó un estudio de casos, observacional, transversal y descriptivo con algunos aspectos analíticos en personas con SW del Municipio Sandino. Se utilizaron las medidas de resumen para variables cualitativas y la prueba de X² para medir asociación al 95 % de certeza. Resultados: 15 individuos presentaron hipoacusia neurosensorial de diferentes distribución e intensidad, con predominio de los ojos pardos y azules bilaterales. Se detectó mayor frecuencia de individuos hipoacúsicos entre los que tenían ojos azules con asociación entre las dos variables (X²= 6,47, gl = 1; p = 0.01. La intensidad de la hipoacusia fue mayor entre los individuos con ojos azules (85.7 % con hipoacusia severa o profunda 3 veces superior que en los otros colores de los ojos. Conclusiones: Existe relación entre el color azul del iris y la presencia de la hipoacusia y mayor intensidad de esta última en individuos con SW.Background: Although sensorineural hearing loss and iris pigmentary changes have been described, the association between these two elements has not been previously studied. Objectives: to describe and analyze the possible association of hypoacusis and the intensity of this with the color of the iris in a family suffering from this syndrome; which will constitute a new contribution to the understanding of Waardenburg Syndrome (WS. Material and Method: an observational, cross-sectional and descriptive case-study was carried out having some analytic aspects in people suffering from WS in Sandino municipality, Pinar del Rio. Measures

  17. La iridotomía periférica con Nd YAG láser en el síndrome de dispersión pigmentaria/glaucoma pigmentario Nd YAG laser peripheral iridotomy in the pigment dispersion syndrome/pigmentary glaucoma

    Directory of Open Access Journals (Sweden)

    Francisco García González

    2002-06-01

    Full Text Available En 13 ojos con diagnóstico de síndrome de dispersión pigmentaria y 5 con glaucoma pigmentario, inicialmente se evaluaron la presión intraocular, los signos de dispersión pigmentaria, la relación excavación-papila y las alteraciones del campo visual; se realizó iridotomía periférica Nd YAG láser en los ojos con este síndrome y trabeculectomía a los que presentaban glaucoma pigmentario. Se chequearon cada 4 meses hasta 24 meses. Once ojos con iris cóncavo mostraron aplanamiento del iris y 2 con iris convexos no variaron con la iridotomía láser; en los 18 ojos disminuyeron evidentemente los signos de dispersión pigmentaria y la presión intraocular permaneció estable, la cual mejoró en los tratados con la trabeculectomía. En el síndrome de dispersión pigmentaria es muy frecuente la configuración cóncava del iris; la iridotomía lo aplana y evita el roce iridozonular, disminuyendo la dispersión y deposición de pigmento que prevendría el aumento de la presión intraocular y el glaucoma pigmentario.The intraocular pressure, the signs of pigment dispersion, the excavation-papilla relation and the alterations of the visual field were initially evaluated in 13 eyes with diagnosis of pigment dispersion syndrome and 5 with pigmentary glaucoma. Nd YAG laser perypheral iridotomy was performed in patients with this syndrome, whereas those who presented pigmentary glaucoma underwent trabeculectomy. They were checked every 4 months up to 24 months. 11 eyes with concave iris showed flattening of the iris and 2 with convex iris did not vary with laser iridotomy. An evident reduction of the signs of pigment dispersion was observed in the 18 eyes. The intraocular pressure remained stable and it improved in those treated with trabeculectomy. In the pigment dispersion syndrome it is very frequent the concave configuration of the iris; the iridotomy flattens it and avoids the iridozonular friction, reducing the dispersion and deposition of

  18. A Severe Case of Pigmentary Glaucoma in a Child With a Family History of Pigment Dispersion Syndrome.

    Science.gov (United States)

    Aragno, Vittoria; Zeboulon, Pierre; Baudouin, Christophe; Labbé, Antoine

    2016-08-01

    To report a case of severe pigmentary glaucoma (PG) in a 13-year-old boy of a family affected by pigment dispersion syndrome (PDS). A 13-year-old child was referred to our hospital for severe bilateral glaucoma. A complete ophthalmologic evaluation including refraction, intraocular pressure, central corneal thickness, slit-lamp biomicroscopy, gonioscopy, fundus examination, and ultrasound biomicroscopy was performed. Family members were also examined and a family pedigree was obtained. Ophthalmologic examination revealed a severe bilateral PG with Krukenberg spindle and a widely open heavily pigmented iridocorneal angle. Ultrasound biomicroscopy showed a deep anterior chamber with pronounced iris concavity in both eyes. Within his family, his 15-year-old sister and 7-year-old brother were both affected by PDS diagnosed on gonioscopy findings. We report for the first time a severe case of pediatric PG with a family history of PDS. This case demonstrates that accurate screening is necessary in cases of familial PDS and PG, even in the pediatric population.

  19. [Pigment dispersion syndrome and pigmentary glaucoma. Morphometric analysis of the anterior chamber segment with SL-OCT].

    Science.gov (United States)

    Birner, B; Tourtas, T; Wessel, J M; Jünemann, A G; Mardin, C Y; Kruse, F E; Laemmer, R

    2014-01-01

    The purpose of this study was to analyze if anterior chamber parameters are risk factors for the development of pigment dispersion syndrome (PDS) and/or for the conversion to pigmentary glaucoma (PG). This study included a total of 63 eyes from 35 patients with PDS and PG and 65 eyes from 49 unaffected volunteers as the control group. The following parameters were measured by slit lamp optical coherence tomography (SL-OCT): anterior chamber volume (ACV) and depth (ACD), angle opening distance (AOD) and the trabecular iris space area (TISA) at 500 µm and 750 μm from the scleral spur. Comparisons between the following groups were performed: between the PDS/PG and the control group, between PDS and PG and between male and female patients. The results of ACV, ACD, AOD and TISA were significantly higher in PDS/PG patients when compared to the control group. There were no significant differences between PDS and PG. The gender-specific comparison also showed no significant differences. Significantly higher anterior chamber parameters are a possible risk factor for development of PDS; however, a higher risk of conversion to PG does not seem to correlate with increased anterior chamber parameters. The parameters of the anterior chamber are apparently not associated with the male predominance of PDS and PG.

  20. Iris reactor conceptual design

    International Nuclear Information System (INIS)

    Carelli, M.D.; Conway, L.E.; Petrovic, B.; Paramonov, D.V.; Galvin, M.; Todreas, N.E.; Lombardi, C.V.; Maldari, F.; Ricotti, M.E.; Cinotti, L.

    2001-01-01

    IRIS (International Reactor Innovative and Secure) is a modular, integral, light water cooled, low-to-medium power (100-350 MWe) reactor which addresses the requirements defined by the US DOE for Generation IV reactors, i.e., proliferation resistance, enhanced safety, improved economics and fuel cycle sustainability. It relies on the proven technology of light water reactors and features innovative engineering, but it does not require new technology development. This paper discusses the current reference IRIS design, which features a 1000 MWt thermal core with proven 5%-enriched uranium oxide fuel and five-year long straight burn fuel cycle, integral reactor vessel housing helical tube steam generators and immersed spool pumps. Other major contributors to the high level of safety and economic attractiveness are the safety by design and optimized maintenance approaches, which allow elimination of some classes of accidents, lower capital cost, long operating cycle, and high capacity factors. (author)

  1. IRiS: construction of ARG networks at genomic scales.

    Science.gov (United States)

    Javed, Asif; Pybus, Marc; Melé, Marta; Utro, Filippo; Bertranpetit, Jaume; Calafell, Francesc; Parida, Laxmi

    2011-09-01

    Given a set of extant haplotypes IRiS first detects high confidence recombination events in their shared genealogy. Next using the local sequence topology defined by each detected event, it integrates these recombinations into an ancestral recombination graph. While the current system has been calibrated for human population data, it is easily extendible to other species as well. IRiS (Identification of Recombinations in Sequences) binary files are available for non-commercial use in both Linux and Microsoft Windows, 32 and 64 bit environments from https://researcher.ibm.com/researcher/view_project.php?id = 2303 parida@us.ibm.com.

  2. Integrated risk information system (IRIS)

    Energy Technology Data Exchange (ETDEWEB)

    Tuxen, L. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The Integrated Risk Information System (IRIS) is an electronic information system developed by the US Environmental Protection Agency (EPA) containing information related to health risk assessment. IRIS is the Agency`s primary vehicle for communication of chronic health hazard information that represents Agency consensus following comprehensive review by intra-Agency work groups. The original purpose for developing IRIS was to provide guidance to EPA personnel in making risk management decisions. This original purpose for developing IRIS was to guidance to EPA personnel in making risk management decisions. This role has expanded and evolved with wider access and use of the system. IRIS contains chemical-specific information in summary format for approximately 500 chemicals. IRIS is available to the general public on the National Library of Medicine`s Toxicology Data Network (TOXNET) and on diskettes through the National Technical Information Service (NTIS).

  3. Pigment deposition on the central aspect of the posterior lens capsule in pigmentary dispersion.

    Science.gov (United States)

    Nagarajaiah, Shubha; Shun-Shin, Georges Adrien

    2011-01-01

    We describe a case of an increasing pigmentary plaque on the posterior surface of the lens during follow-up of a case of pigment dispersion syndrome and suggest that this is a new sign of pigment dispersion.

  4. Pigment deposition on the central aspect of the posterior lens capsule in pigmentary dispersion

    OpenAIRE

    Nagarajaiah, Shubha; Shun-Shin, Georges Adrien

    2011-01-01

    We describe a case of an increasing pigmentary plaque on the posterior surface of the lens during follow-up of a case of pigment dispersion syndrome and suggest that this is a new sign of pigment dispersion.

  5. IRIS-economics review

    International Nuclear Information System (INIS)

    Miller, K.

    2005-01-01

    IRIS is a medium sized advanced light water cooled modular reactor being developed by an international Group led by Westinghouse/BNFL. This reactor design is aimed at a broad spectrum of Utilities looking to install nuclear capacity to match market demands, or at emerging Nations with specific financial constraints looking to strategically optimise their debit levels. The IRIS building block is a multiple module sized at 335 MWe, with a construction period of 3 years and a 60-year plant life. Modules can be installed individually or in parks. In the latter case, deployment can be in single modules or in pairs (twin-unit); both will be built in staggered fashion at time intervals as dictated by economic and market considerations. One of the unique features of IRIS is its ability to offer reduction in costs through increased experience 'Learning' at a single site: In construction, the principal benefit is derived for subsequent modules, and is dependent on maintaining the 'core' team throughout. This is particularly important if there is any significant period between the completion of say module 1 and the start of module 2. This time frame will be driven by the overall market size, projected growth in demand and the level of financial risk the utility is prepared to accept. Learning benefits in construction are derived from skills and experience retention impacting on reducing the number of inputs and construction time. Learning in operation may benefit from a certain delay between modules as this allows operators to build up their 'cumulative experience'. Reactor operations on day 1 would be significantly different from those of say 3 years later. These benefits would be passed on to modules 2 and 3, which would realise them from day 1. Learning in operation is dependent on the ability to retain within the organisation knowledge and records of key events. The benefits from Learning in operation may also be applicable to different sites, in different countries. It

  6. IRIS Mission Operations Director's Colloquium

    Science.gov (United States)

    Carvalho, Robert; Mazmanian, Edward A.

    2014-01-01

    Pursuing the Mysteries of the Sun: The Interface Region Imaging Spectrograph (IRIS) Mission. Flight controllers from the IRIS mission will present their individual experiences on IRIS from development through the first year of flight. This will begin with a discussion of the unique nature of IRISs mission and science, and how it fits into NASA's fleet of solar observatories. Next will be a discussion of the critical roles Ames contributed in the mission including spacecraft and flight software development, ground system development, and training for launch. This will be followed by experiences from launch, early operations, ongoing operations, and unusual operations experiences. The presentation will close with IRIS science imagery and questions.

  7. The IRIS user-guide

    International Nuclear Information System (INIS)

    Adams, M.A.

    1997-10-01

    This is the first version of the IRIS User-Guide. IRIS is continually evolving and improving and so some of the information contained within this manual will become out of date quite quickly. The basics behind the operation of IRIS, however, should remain essentially constant for the foreseeable future. Updated manuals will be produced when appropriate although it should always be remembered that the most up-to-date sources of information concerning IRIS are the instrument scientist and the local contacts for the experiments. It would be appreciated, however, if this user-guide were to be the first point of call. (author)

  8. [Evaluation of Iris Morphology Viewed through Stromal Edematous Corneas by Infrared Camera].

    Science.gov (United States)

    Kobayashi, Masaaki; Morishige, Naoyuki; Morita, Yukiko; Yamada, Naoyuki; Kobayashi, Motomi; Sonoda, Koh-Hei

    2016-02-01

    We reported that the application of infrared camera enables us to observe iris morphology in Peters' anomaly through edematous corneas. To observe the iris morphology in bullous keratopathy or failure grafts with an infrared camera. Eleven bullous keratopathy or failure grafts subjects (6 men and 5 women, mean age ± SD; 72.7 ± 13.0 years old) were enrolled in this study. The iris morphology was observed by applying visible light mode and near infrared light mode of infrared camera (MeibomPen). The detectability of pupil shapes, iris patterns and presence of iridectomy was evaluated. Infrared mode observation enabled us to detect the pupil shapes in 11 out of 11 cases, iris patterns in 3 out of 11 cases, and presence of iridetomy in 9 out of 11 cases although visible light mode observation could not detect any iris morphological changes. Applying infrared optics was valuable for observation of the iris morphology through stromal edematous corneas.

  9. Secondary pigmentary glaucoma in patients with underlying primary pigment dispersion syndrome

    Directory of Open Access Journals (Sweden)

    Sivaraman KR

    2013-03-01

    Full Text Available Kavitha R Sivaraman, Chirag G Patel, Thasarat S Vajaranant, Ahmad A ArefDepartment of Ophthalmology and Visual Sciences, Illinois Eye and Ear Infirmary, University of Illinois at Chicago School of Medicine, Chicago, IL, USAAbstract: Primary pigment dispersion syndrome (PPDS is a bilateral condition that occurs in anatomically predisposed individuals. PPDS may evolve into pigmentary glaucoma, but it is difficult to predict which patients will progress. Secondary pigment dispersion is more often unilateral and acquired as a result of surgery, trauma, or intraocular tumor, but can likewise lead to pigmentary glaucoma. We report two cases of patients with bilateral PPDS who developed secondary pigment dispersion and pigmentary glaucoma in one eye. Patients with PPDS who acquire a secondary mechanism of pigment dispersion may be at an increased risk of progression to pigmentary glaucoma, presumably due to an increased burden of liberated pigment. In addition to regular surveillance for progression to glaucoma from PPDS, secondary causes of pigmentary dispersion in these eyes should be considered when patients present with grossly asymmetric findings. When secondary pigment dispersion is identified in eyes with PPDS, we recommend prompt intervention to alleviate the cause of secondary pigment dispersion and/or aggressive control of intraocular pressure to limit glaucomatous damage.Keywords: primary pigment dispersion syndrome, pigmentary glaucoma

  10. Cross-sensor iris recognition through kernel learning.

    Science.gov (United States)

    Pillai, Jaishanker K; Puertas, Maria; Chellappa, Rama

    2014-01-01

    Due to the increasing popularity of iris biometrics, new sensors are being developed for acquiring iris images and existing ones are being continuously upgraded. Re-enrolling users every time a new sensor is deployed is expensive and time-consuming, especially in applications with a large number of enrolled users. However, recent studies show that cross-sensor matching, where the test samples are verified using data enrolled with a different sensor, often lead to reduced performance. In this paper, we propose a machine learning technique to mitigate the cross-sensor performance degradation by adapting the iris samples from one sensor to another. We first present a novel optimization framework for learning transformations on iris biometrics. We then utilize this framework for sensor adaptation, by reducing the distance between samples of the same class, and increasing it between samples of different classes, irrespective of the sensors acquiring them. Extensive evaluations on iris data from multiple sensors demonstrate that the proposed method leads to improvement in cross-sensor recognition accuracy. Furthermore, since the proposed technique requires minimal changes to the iris recognition pipeline, it can easily be incorporated into existing iris recognition systems.

  11. The Economics of IRIS

    International Nuclear Information System (INIS)

    Miller, K.; Paramonov, D.

    2002-01-01

    IRIS (International Reactor Innovative and Secure) is a small to medium advanced light water cooled modular reactor being developed by an international consortium led by Westinghouse/BNFL. This reactor design is specifically aimed at utilities looking to install new (or replacement) nuclear capacity to match market demands, or at developing countries for their distributed power needs. To determine the optimal configuration for IRIS, analysis was undertaken to establish Generation Costs ($/MWh) and Internal Rate of Return (IRR %) to the Utility at alternative power ratings. This was then combined with global market projections for electricity demand out to 2030, segmented into key geographical regions. Finally this information is brought together to form insights, conclusions and recommendations regarding the optimal design. The resultant analysis reveals a single module sized at 335 MWe, with a construction period of 3 years and a 60-year plant life. Individual modules can be installed in a staggered fashion (3 equivalent to 1005 MWe) or built in pairs (2 sets of twin units' equivalent to 1340 MWe). Uncertainty in Market Clearing Price for electricity, Annual Operating Costs and Construction Costs primarily influence lifetime Net Present Values (NPV) and hence IRR % for Utilities. Generation Costs in addition are also influenced by Fuel Costs, Plant Output, Plant Availability and Plant Capacity Factor. Therefore for a site based on 3 single modules, located in North America, Generations Costs of 28.5 $/MWh are required to achieve an IRR of 20%, a level which enables IRIS to compete with all other forms of electricity production. Plant size is critical to commercial success. Sustained (lifetime) high factors for Plant Output, Availability and Capacity Factor are required to achieve a competitive advantage. Modularity offers Utilities the option to match their investments with market conditions, adding additional capacity as and when the circumstances are right

  12. New methods in iris recognition.

    Science.gov (United States)

    Daugman, John

    2007-10-01

    This paper presents the following four advances in iris recognition: 1) more disciplined methods for detecting and faithfully modeling the iris inner and outer boundaries with active contours, leading to more flexible embedded coordinate systems; 2) Fourier-based methods for solving problems in iris trigonometry and projective geometry, allowing off-axis gaze to be handled by detecting it and "rotating" the eye into orthographic perspective; 3) statistical inference methods for detecting and excluding eyelashes; and 4) exploration of score normalizations, depending on the amount of iris data that is available in images and the required scale of database search. Statistical results are presented based on 200 billion iris cross-comparisons that were generated from 632500 irises in the United Arab Emirates database to analyze the normalization issues raised in different regions of receiver operating characteristic curves.

  13. Are mice pigmentary genes throwing light on humans?

    Directory of Open Access Journals (Sweden)

    Bose S

    1993-01-01

    Full Text Available In this article the rapid advances made in the molecular genetics of inherited disorders of hypo and hyperpigmentation during the past three years are reviewed. The main focus is on studies in mice as compared to homologues in humans. The main hypomelanotic diseases included are, piebaldism (white spotting due to mutations of c-KIT, PDGF and MGF genes; vitiligo (microphathalmia mice mutations of c-Kit and c-fms genes; Waardenburg syndrome (splotch locus mutations of mice PAX-3 or human Hup-2 genes; albinism (mutations of tyrosinase genes, Menkes disease (Mottled mouse, premature graying (mutations in light/brown locus/gp75/ TRP-1; Griscelli disease (mutations in TRP-1 and steel; Prader-willi and Angelman syndromes, tyrosinase-positive oculocutaneous albinism and hypomelanosis of lto (mutations of pink-eyed dilution gene/mapping to human chromosomes 15 q 11.2 - q12; and human platelet storage pool deficiency diseases due to defects in pallidin, an erythrocyte membrane protein (pallid mouse / mapping to 4.2 pallidin gene. The genetic characterization of hypermelanosis includes, neurofibromatosis 1 (Café-au-lait spots and McCune-Albright Syndrome. Rapid evolving knowledge about pigmentary genes will increase further the knowledge about these hypo and hyperpigmentary disorders.

  14. Iris Matching Based on Personalized Weight Map.

    Science.gov (United States)

    Dong, Wenbo; Sun, Zhenan; Tan, Tieniu

    2011-09-01

    Iris recognition typically involves three steps, namely, iris image preprocessing, feature extraction, and feature matching. The first two steps of iris recognition have been well studied, but the last step is less addressed. Each human iris has its unique visual pattern and local image features also vary from region to region, which leads to significant differences in robustness and distinctiveness among the feature codes derived from different iris regions. However, most state-of-the-art iris recognition methods use a uniform matching strategy, where features extracted from different regions of the same person or the same region for different individuals are considered to be equally important. This paper proposes a personalized iris matching strategy using a class-specific weight map learned from the training images of the same iris class. The weight map can be updated online during the iris recognition procedure when the successfully recognized iris images are regarded as the new training data. The weight map reflects the robustness of an encoding algorithm on different iris regions by assigning an appropriate weight to each feature code for iris matching. Such a weight map trained by sufficient iris templates is convergent and robust against various noise. Extensive and comprehensive experiments demonstrate that the proposed personalized iris matching strategy achieves much better iris recognition performance than uniform strategies, especially for poor quality iris images.

  15. Secondary pigmentary glaucoma in patients with underlying primary pigment dispersion syndrome.

    Science.gov (United States)

    Sivaraman, Kavitha R; Patel, Chirag G; Vajaranant, Thasarat S; Aref, Ahmad A

    2013-01-01

    Primary pigment dispersion syndrome (PPDS) is a bilateral condition that occurs in anatomically predisposed individuals. PPDS may evolve into pigmentary glaucoma, but it is difficult to predict which patients will progress. Secondary pigment dispersion is more often unilateral and acquired as a result of surgery, trauma, or intraocular tumor, but can likewise lead to pigmentary glaucoma. We report two cases of patients with bilateral PPDS who developed secondary pigment dispersion and pigmentary glaucoma in one eye. Patients with PPDS who acquire a secondary mechanism of pigment dispersion may be at an increased risk of progression to pigmentary glaucoma, presumably due to an increased burden of liberated pigment. In addition to regular surveillance for progression to glaucoma from PPDS, secondary causes of pigmentary dispersion in these eyes should be considered when patients present with grossly asymmetric findings. When secondary pigment dispersion is identified in eyes with PPDS, we recommend prompt intervention to alleviate the cause of secondary pigment dispersion and/or aggressive control of intraocular pressure to limit glaucomatous damage.

  16. Iris recognition via plenoptic imaging

    Science.gov (United States)

    Santos-Villalobos, Hector J.; Boehnen, Chris Bensing; Bolme, David S.

    2017-11-07

    Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.

  17. Micropropagation of Iris sp.

    Science.gov (United States)

    Jevremović, Slađana; Jeknić, Zoran; Subotić, Angelina

    2013-01-01

    Irises are perennial plants widely used as ornamental garden plants or cut flowers. Some species accumulate secondary metabolites, making them highly valuable to the pharmaceutical and perfume industries. Micropropagation of irises has successfully been accomplished by culturing zygotic embryos, different flower parts, and leaf base tissues as starting explants. Plantlets are regenerated via somatic embryogenesis, organogenesis, or both processes at the same time depending on media composition and plant species. A large number of uniform plants are produced by somatic embryogenesis, however, some species have decreased morphogenetic potential overtime. Shoot cultures obtained by organogenesis can be multiplied for many years. Somatic embryogenic tissue can be reestablished from leaf bases of in vitro-grown shoots. The highest number of plants can be obtained by cell suspension cultures. This chapter describes effective in vitro plant regeneration protocols for Iris species from different types of explants by somatic embryogenesis and/or organogenesis suitable for the mass propagation of ornamental and pharmaceutical irises.

  18. IRIS core criticality calculations

    International Nuclear Information System (INIS)

    Jecmenica, R.; Trontl, K.; Pevec, D.; Grgic, D.

    2003-01-01

    Three-dimensional Monte Carlo computer code KENO-VI of CSAS26 sequence of SCALE-4.4 code system was applied for pin-by-pin calculations of the effective multiplication factor for the first cycle IRIS reactor core. The effective multiplication factors obtained by the above mentioned Monte Carlo calculations using 27-group ENDF/B-IV library and 238-group ENDF/B-V library have been compared with the effective multiplication factors achieved by HELIOS/NESTLE, CASMO/SIMULATE, and modified CORD-2 nodal calculations. The results of Monte Carlo calculations are found to be in good agreement with the results obtained by the nodal codes. The discrepancies in effective multiplication factor are typically within 1%. (author)

  19. Bartus Iris biometrics

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, R.; Grace, W.

    1996-07-01

    This is the final report of a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). We won a 1994 R&D 100 Award for inventing the Bartas Iris Verification System. The system has been delivered to a sponsor and is no longer available to us. This technology can verify the identity of a person for purposes of access control, national security, law enforcement, forensics, counter-terrorism, and medical, financial, or scholastic records. The technique is non-invasive, psychologically acceptable, works in real-time, and obtains more biometric data than any other biometric except DNA analysis. This project sought to develop a new, second-generation prototype instrument.

  20. Spectrally tuned structural and pigmentary coloration of birdwing butterfly wing scales.

    Science.gov (United States)

    Wilts, Bodo D; Matsushita, Atsuko; Arikawa, Kentaro; Stavenga, Doekele G

    2015-10-06

    The colourful wing patterns of butterflies play an important role for enhancing fitness; for instance, by providing camouflage, for interspecific mate recognition, or for aposematic display. Closely related butterfly species can have dramatically different wing patterns. The phenomenon is assumed to be caused by ecological processes with changing conditions, e.g. in the environment, and also by sexual selection. Here, we investigate the birdwing butterflies, Ornithoptera, the largest butterflies of the world, together forming a small genus in the butterfly family Papilionidae. The wings of these butterflies are marked by strongly coloured patches. The colours are caused by specially structured wing scales, which act as a chirped multilayer reflector, but the scales also contain papiliochrome pigments, which act as a spectral filter. The combined structural and pigmentary effects tune the coloration of the wing scales. The tuned colours are presumably important for mate recognition and signalling. By applying electron microscopy, (micro-)spectrophotometry and scatterometry we found that the various mechanisms of scale coloration of the different birdwing species strongly correlate with the taxonomical distribution of Ornithoptera species. © 2015 The Author(s).

  1. Ozonoterapia y electroestimulación en retinosis pigmentaria Ozone therapy and electrical stimulation in pigmentary retinitis

    Directory of Open Access Journals (Sweden)

    Lázaro Joaquín Pérez Aguiar

    2010-06-01

    Full Text Available OBJETIVO: Profundizar en los efectos de la ozonoterapia y electroestimulación sobre la función visual de los pacientes que padecen retinosis pigmentaria. MÉTODOS: Se estudiaron 186 pacientes portadores de retinosis pigmentaria. Fueron agrupados atendiendo a los estadios clínicos de la clasificación cubana (4 grupos. Se aplicó ozonoterapia y electroestimulación, una sesión diaria de cada una durante 14 días. Se realizó un examen oftalmológico antes y después del tratamiento, para la agudeza visual se empleó cartilla de Snellen y para el campo visual cinético tipo Goldman. Los datos estadísticos se analizaron y compararon usando la prueba t de Student. Se consideró p OBJECTIVE: To analyze in depth the effects of ozone therapy and electrical stimulation on the visual function of patients suffering pigmentary retinitis. METHODS: One hundred and eighty six patients carrying pigmentary retinitis were studied. They were grouped according to the clinical staging of the Cuban classification (4 groups. Ozone therapy and electrical stimulations were applied daily for 14 days. An ophthalmologic test before and after the treatment was performed; Snellen´s charter for visual acuity and Goldman-type kinetic visual field. Statistical data were analyzed and compared using Student´s t test. The statistical significance was set at p<0,05. RESULTS: The corrected visual acuity remained the same in the 57 patients grouped in staging 1. Significant changes were observed in the visual field of 16 patients. Regarding the 66 patients in staging 2, corrected visual acuity remained the same in 48 whereas 29 patients experienced significant changes in their visual field. Forty nine patients were included in the staging 3 where corrected visual acuity kept the same value in 38 patients, but very significant changes in the visual field of 27 patients were observed. CONCLUSION: In the Cuban multitherapeutical strategy for the treatment of pigmentary retinitis

  2. Shape adaptive, robust iris feature extraction from noisy iris images.

    Science.gov (United States)

    Ghodrati, Hamed; Dehghani, Mohammad Javad; Danyali, Habibolah

    2013-10-01

    In the current iris recognition systems, noise removing step is only used to detect noisy parts of the iris region and features extracted from there will be excluded in matching step. Whereas depending on the filter structure used in feature extraction, the noisy parts may influence relevant features. To the best of our knowledge, the effect of noise factors on feature extraction has not been considered in the previous works. This paper investigates the effect of shape adaptive wavelet transform and shape adaptive Gabor-wavelet for feature extraction on the iris recognition performance. In addition, an effective noise-removing approach is proposed in this paper. The contribution is to detect eyelashes and reflections by calculating appropriate thresholds by a procedure called statistical decision making. The eyelids are segmented by parabolic Hough transform in normalized iris image to decrease computational burden through omitting rotation term. The iris is localized by an accurate and fast algorithm based on coarse-to-fine strategy. The principle of mask code generation is to assign the noisy bits in an iris code in order to exclude them in matching step is presented in details. An experimental result shows that by using the shape adaptive Gabor-wavelet technique there is an improvement on the accuracy of recognition rate.

  3. Comparison and evaluation of datasets for off-angle iris recognition

    Science.gov (United States)

    Kurtuncu, Osman M.; Cerme, Gamze N.; Karakaya, Mahmut

    2016-05-01

    In this paper, we investigated the publicly available iris recognition datasets and their data capture procedures in order to determine if they are suitable for the stand-off iris recognition research. Majority of the iris recognition datasets include only frontal iris images. Even if a few datasets include off-angle iris images, the frontal and off-angle iris images are not captured at the same time. The comparison of the frontal and off-angle iris images shows not only differences in the gaze angle but also change in pupil dilation and accommodation as well. In order to isolate the effect of the gaze angle from other challenging issues including dilation and accommodation, the frontal and off-angle iris images are supposed to be captured at the same time by using two different cameras. Therefore, we developed an iris image acquisition platform by using two cameras in this work where one camera captures frontal iris image and the other one captures iris images from off-angle. Based on the comparison of Hamming distance between frontal and off-angle iris images captured with the two-camera- setup and one-camera-setup, we observed that Hamming distance in two-camera-setup is less than one-camera-setup ranging from 0.05 to 0.001. These results show that in order to have accurate results in the off-angle iris recognition research, two-camera-setup is necessary in order to distinguish the challenging issues from each other.

  4. Aqueous humor tyrosinase activity is indicative of iris melanocyte toxicity.

    Science.gov (United States)

    Mahanty, Sarmistha; Kawali, Ankush A; Dakappa, Shruthi Shirur; Mahendradas, Padmamalini; Kurian, Mathew; Kharbanda, Varun; Shetty, Rohit; Setty, Subba Rao Gangi

    2017-09-01

    Antibiotics such as fluoroquinolones (FQLs) are commonly used to treat ocular infections but are also known to cause dermal melanocyte toxicity. The release of dispersed pigments from the iris into the aqueous humor has been considered a possible ocular side effect of the systemic administration of FQLs such as Moxifloxacin, and this condition is known as bilateral acute iris transillumination (BAIT). Bilateral acute depigmentation of iris (BADI) is a similar condition, with iris pigment released into the aqueous, but it has not been reported as a side effect of FQL. Iris pigments are synthesized by the melanogenic enzyme tyrosinase (TYR) and can be detected but not quantified by using slit-lamp biomicroscopy. The correlation between dispersed pigments in the aqueous and the extent of melanocyte toxicity due to topical antibiotics in vivo is not well studied. Here, we aimed to study the effect of topical FQLs on iris tissue, the pigment release in the aqueous humor and the development of clinically evident iris atrophic changes. We evaluated this process by measuring the activity of TYR in the aqueous humor of 82 healthy eyes undergoing cataract surgery following topical application of FQLs such as Moxifloxacin (27 eyes, preservative-free) or Ciprofloxacin (29 eyes, with preservative) or the application of non-FQL Tobramycin (26 eyes, with preservative) as a control. In addition, the patients were questioned and examined for ocular side effects in pre- and post-operative periods. Our data showed a significantly higher mean TYR activity in the aqueous humor of Ciprofloxacin-treated eyes compared to Moxifloxacin- (preservative free, p iris melanocytes. However, the reduced TYR activity in the aqueous of Moxifloxacin-treated eyes was possibly due to the presence of a higher drug concentration, which inhibits TYR activity. Consistently, immunoblotting analysis of the aqueous humor from both Ciprofloxacin- and Moxifloxacin-treated eyes showed the presence of soluble

  5. Academy Distance Learning Tools (IRIS) -

    Data.gov (United States)

    Department of Transportation — IRIS is a suite of front-end web applications utilizing a centralized back-end Oracle database. The system fully supports the FAA Academy's Distance Learning Program...

  6. Iris Murdoch armastusest / Udo uibo

    Index Scriptorium Estoniae

    Uibo, Udo, 1956-

    2010-01-01

    Londoni Kingstoni ülikool omandas 50 000 naesterlingi eest 164 Iris Murdochi kirja prantsuse kirjanikule, keeleeksperimentaatorile Raymond Quenaule, millest selgub Murdochi ühepoolne ning vastamata jäänud tunne Quenau suhtes.

  7. Integrated Risk Information System (IRIS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA?s Integrated Risk Information System (IRIS) is a compilation of electronic reports on specific substances found in the environment and their potential to cause...

  8. ANTIMICROBIAL ACTIVITY OF EXTRACTS OF IRIS HUNGARICA AND IRIS SIBIRICA

    Directory of Open Access Journals (Sweden)

    Kovalev V. M.

    2017-06-01

    Full Text Available Introduction. Referring to the latest data, infectious diseases command a large part of among the total number of pathologies in the world and are an important problem in medicine. The leading role in prevention and treatment of diseases of microbial origin belongs to antibacterial chemotherapeutic agents. Advantages of antibiotics of synthetic origin are the high activity compared to phytogenic drugs. But it is known that microorganisms can release the resistance to synthetic antibiotics, so the use of drugs based on the plant materials is appropriate: phytogenic drugs more rarely induce the formation of resistance of the strains of microorganisms, they have a gentle action, can be used for a long-term, have the low cost. Therefore, it is appropriate to examine the drug plants with the aim of determination their antibacterial activity.Iris hungarica Waldst et Kit. and Iris sibirica L. are the representatives of the family Iridaceae, genus Iris and they have a wide spectrum of the pharmacological activity. Biologically active substances that were recovered from plants of the genus Iris (tectoridin, iristectorigenin B, nigracin, kaempferol, quercetin, etc. exhibited an antitumor, antimicrobial, estrogenic, insecticidal, antiplasmatic, anticholinesterase action, they were the inhibitors of enzymes and exhibited the immunomodulatory properties, which made these plants perspective for the research study. Raw materials Irises are constituent components of more than 9 medicines. Materials and Methods. The objects of the study were the leaves and rhizomes of Iris hungarica and Iris sibirica that were prepared during the growing season in 2014 in the M.M. Gryshko National botanical garden (Kiev, Ukraine. The dry and lipophilic extracts from the leaves and rhizomes of Irises were used to establish the antimicrobial activity. For the study of extracts antimicrobial activity was used agar well diffusion method. According to the WHO recommendations the

  9. A new objective criterion for IRIS localization

    International Nuclear Information System (INIS)

    Basit, A.

    2010-01-01

    Iris localization is the most important step in iris recognition systems. For commonly used databases, exact data is not given which describe the true results of localization. To cope with this problem a new objective criterion for iris localization is proposed in this paper based on our visual system. A specific number of points are selected on pupil boundary, iris boundary, upper eyelid and lower eyelid using the original image and then distance from these points to the result of complete iris localization has been calculated. If the determined distance is below a certain threshold then iris localization is considered correct. Experimental results show that proposed criterion is very effective. (author)

  10. Improved Iris Recognition through Fusion of Hamming Distance and Fragile Bit Distance.

    Science.gov (United States)

    Hollingsworth, Karen P; Bowyer, Kevin W; Flynn, Patrick J

    2011-12-01

    The most common iris biometric algorithm represents the texture of an iris using a binary iris code. Not all bits in an iris code are equally consistent. A bit is deemed fragile if its value changes across iris codes created from different images of the same iris. Previous research has shown that iris recognition performance can be improved by masking these fragile bits. Rather than ignoring fragile bits completely, we consider what beneficial information can be obtained from the fragile bits. We find that the locations of fragile bits tend to be consistent across different iris codes of the same eye. We present a metric, called the fragile bit distance, which quantitatively measures the coincidence of the fragile bit patterns in two iris codes. We find that score fusion of fragile bit distance and Hamming distance works better for recognition than Hamming distance alone. To our knowledge, this is the first and only work to use the coincidence of fragile bit locations to improve the accuracy of matches.

  11. Iris Template Protection Based on Local Ranking

    Directory of Open Access Journals (Sweden)

    Dongdong Zhao

    2018-01-01

    Full Text Available Biometrics have been widely studied in recent years, and they are increasingly employed in real-world applications. Meanwhile, a number of potential threats to the privacy of biometric data arise. Iris template protection demands that the privacy of iris data should be protected when performing iris recognition. According to the international standard ISO/IEC 24745, iris template protection should satisfy the irreversibility, revocability, and unlinkability. However, existing works about iris template protection demonstrate that it is difficult to satisfy the three privacy requirements simultaneously while supporting effective iris recognition. In this paper, we propose an iris template protection method based on local ranking. Specifically, the iris data are first XORed (Exclusive OR operation with an application-specific string; next, we divide the results into blocks and then partition the blocks into groups. The blocks in each group are ranked according to their decimal values, and original blocks are transformed to their rank values for storage. We also extend the basic method to support the shifting strategy and masking strategy, which are two important strategies for iris recognition. We demonstrate that the proposed method satisfies the irreversibility, revocability, and unlinkability. Experimental results on typical iris datasets (i.e., CASIA-IrisV3-Interval, CASIA-IrisV4-Lamp, UBIRIS-V1-S1, and MMU-V1 show that the proposed method could maintain the recognition performance while protecting the privacy of iris data.

  12. Presumed atypical HDR syndrome associated with Band Keratopathy and pigmentary retinopathy.

    Science.gov (United States)

    Kim, Cinoo; Cheong, Hae Il; Kim, Jeong Hun; Yu, Young Suk; Kwon, Ji Won

    2011-01-01

    This report describes presumed atypical hypoparathyroidism, deafness, and renal dysplasia (HDR) syndrome associated with unexpected ocular findings. The patient had exotropia, bilateral band keratopathy, and pigmentary retinopathy, including attenuated retinal vessels and atrophy of the retinal pigment epithelium. Even though the calcific plaques were successfully removed, visual acuity in both eyes gradually decreased and electroretinography was extinguished. Copyright 2009, SLACK Incorporated.

  13. IRIS pre-application licensing

    International Nuclear Information System (INIS)

    Carelli, Mario D.; Kling, Charles L.; Ritterbusch, Stanley E.

    2003-01-01

    This paper presents the approach to pre-application licensing by the International Reactor Innovative and Secure (IRIS), and advanced, integral reactor design with a thermal power of 1000 MW. The rationale for the pre-application licensing is discussed. Since IRIS technology is based on proven LWR experience, the project will rely on AP600/AP1000 precedent and will focus during the pre-application on long lead and novel items. A discussion of the evolution of the project to significantly reduce licensing issues is provided, followed by a summary of the IRIS safety-by-design which provides a formidable first step in the Defense in Depth approach. The effects of the safety-by-design, as well as of passive systems, on the IRIS safety will be investigated in a proposed testing program that will be reviewed by NRC during the pre-application. Documentation to be provided to NRC is discussed. Early design analyses indicate that the benefits of the IRIS safety-by-design approach are so significant that the basic premise of current emergency planning regulations (i.e., likelihood of core damage) will be reduced to the extent that special emergency response planning beyond the exclusion area boundary may not be needed. How this very significant outcome can be effected through a highly risk-informed licensing is discussed. (author)

  14. 77 FR 31869 - Iris Lacustris (Dwarf Lake Iris); Draft Recovery Plan for Review and Comment

    Science.gov (United States)

    2012-05-30

    ...-FF03E00000] Iris Lacustris (Dwarf Lake Iris); Draft Recovery Plan for Review and Comment AGENCY: Fish and... Service (Service) announces availability for public review of the draft recovery plan for the Iris lacustris (dwarf lake iris), a species that is federally listed as threatened under the Endangered Species...

  15. IRIS Toxicological Review of Acrolein (2003 Final)

    Science.gov (United States)

    EPA announced the release of the final report, Toxicological Review of Acrolein: in support of the Integrated Risk Information System (IRIS). The updated Summary for Acrolein and accompanying toxicological review have been added to the IRIS Database.

  16. IRIS Toxicological Review of Chloroform (Final Report)

    Science.gov (United States)

    EPA is announcing the release of the final report, Toxicological Review of Chloroform: in support of the Integrated Risk Information System (IRIS). The updated Summary for Chloroform and accompanying Quickview have also been added to the IRIS Database.

  17. PLATEAU IRIS SYNDROME--CASE SERIES.

    Science.gov (United States)

    Feraru, Crenguta Ioana; Pantalon, Anca Delia; Chiselita, Dorin; Branisteanu, Daniel

    2015-01-01

    Plateau iris is characterized by closing the anterior chamber angle due to a large ciliary body or due to its anterior insertion that alters the position of iris periphery in respect to the trabecular meshwork. There are two aspects that need to be differentiated: plateau iris configuration and plateau iris syndrome. The first describes a situation when the iris root is flat and the anterior chamber is not shallow, the latter refers to a post laser iridotomy condition in which a patent iridotomy has removed the relative pupillary block, but goniscopically confirmed angle closure recurs without central shallowing of the anterior chamber. Isolated plateau iris syndrome is rare compared to plateau iris configuration. We hereby present two case reports of plateau iris syndrome in young patients who came to an ophthalmologic consult by chance.

  18. IRIS and the National Research Council (NRC)

    Science.gov (United States)

    Since the 2011 National Academies’ National Research Council (NRC) review of the IRIS Program's assessment of Formaldehyde, EPA and NRC have had an ongoing relationship into the improvements of developing the IRIS Assessments.

  19. Quality assessment for online iris images

    CSIR Research Space (South Africa)

    Makinana, S

    2015-01-01

    Full Text Available Iris recognition systems have attracted much attention for their uniqueness, stability and reliability. However, performance of this system depends on quality of iris image. Therefore there is a need to select good quality images before features can...

  20. Eyelid Localization for Iris Identification

    Directory of Open Access Journals (Sweden)

    T. Ea

    2008-12-01

    Full Text Available This article presents a new eyelid localization algorithm based on a parabolic curve fitting. To deal with eyelashes, low contrast or false detection due to iris texture, we propose a two steps algorithm. First, possible edge candidates are selected by applying edge detection on a restricted area inside the iris. Then, a gradient maximization is applied along every parabola, on a larger area, to refine parameters and select the best one. Experiments have been conducted on a database of 151 iris that have been manually segmented. The performance evaluation is carried out by comparing the segmented images obtained by the proposed method with the manual segmentation. The results are satisfactory in more than 90% of the cases.

  1. Iris Cryptography for Security Purpose

    Science.gov (United States)

    Ajith, Srighakollapu; Balaji Ganesh Kumar, M.; Latha, S.; Samiappan, Dhanalakshmi; Muthu, P.

    2018-04-01

    In today's world, the security became the major issue to every human being. A major issue is hacking as hackers are everywhere, as the technology was developed still there are many issues where the technology fails to meet the security. Engineers, scientists were discovering the new products for security purpose as biometrics sensors like face recognition, pattern recognition, gesture recognition, voice authentication etcetera. But these devices fail to reach the expected results. In this work, we are going to present an approach to generate a unique secure key using the iris template. Here the iris templates are processed using the well-defined processing techniques. Using the encryption and decryption process they are stored, traversed and utilized. As of the work, we can conclude that the iris cryptography gives us the expected results for securing the data from eavesdroppers.

  2. Characterization of a Case of Pigmentary Retinopathy in Sanfilippo Syndrome Type IIIA Associated with Compound Heterozygous Mutations in the SGSH Gene.

    Science.gov (United States)

    Wilkin, Justin; Kerr, Natalie C; Byrd, Kathryn W; Ward, Jewell C; Iannaccone, Alessandro

    2016-06-01

    To report longitudinal phenotypic findings in a patient with Sanfilippo syndrome type IIIA, harboring SGSH mutations, one of which is novel. Heparan-N-sulfatidase enzyme function testing in skin fibroblasts and white blood cells and SGSH gene sequencing were obtained. Clinical office examinations, examinations under anesthesia, electroretinogram, spectral domain optical coherence tomography (SD-OCT), and fundus photography were performed over a 5-year period. Fundus examination revealed a progressive breadcrumb-like pigmentary retinopathy with perifoveal pigmentary involvement. SD-OCT showed loss of normal neuroretinal lamination and cystic macular changes responsive to treatment with carbonic anhydrase inhibitors. Electroretinography exhibited complex characteristics indicative of a generalized retinal rod > cone dysfunction with significant ON > OFF postreceptoral response compromise. Sequencing revealed compound heterozygous mutations in the SGSH gene, the novel c.88G > C (p.A30P) change and a second, previously reported one (c.734G > A, p.R245H). We have identified ocular features of a patient with Sanfilippo syndrome type IIIA harboring a novel SGHS mutation that were not previously known to occur in this disease - namely, a progressive retinopathy with distinctive features, cystic macular changes responsive to carbonic anhydrase inhibitors, and complex electroretinographic abnormalities consistent with postreceptoral dysfunction. SD-OCT imaging revealed retinal lamination changes consistent with previously reported histologic studies. Both the SD-OCT and the electroretinogram changes appear attributable to intraretinal deposition of heparan sulfate.

  3. Automatic quantification of iris color

    DEFF Research Database (Denmark)

    Christoffersen, S.; Harder, Stine; Andersen, J. D.

    2012-01-01

    regions. The result is a blue-brown ratio for each eye. Furthermore, an image clustering approach has been used with promising results. The approach is based on using a sparse dictionary of feature vectors learned from a training set of iris regions. The feature vectors contain both local structural...... information and colour information. For each iris an explanatory histogram is build, containing information about the weighted occurrence of each visual word. A hierarchical agglomerative clustering of the entire set of photos is performed using the distance between the explanatory histograms. The approach...

  4. Ekspert i undervisning - IRIS Connect

    DEFF Research Database (Denmark)

    Wullum, Annemette Heine; Eriksen, Frits Hedegaard

    Ekspert i undervisning – IRIS Connect Credoet bag de seneste års mange læreruddannelsesreformer har været, at flere og dybere kundskaber vil styrke de studerendes forudsætninger for at løse opgaverne i pædagogisk praksis. Et forhold, som bliver overset i forbindelse med uddannelsesreformerne, er...... praksis, og hvad ”effektiv” undervisning er. Hovedantagelserne bag projektet er, at de studerendes personbundne kundskaber kan synliggøres, at deres lægmandsopfattelser af, hvad ”effektiv” undervisning er, kan udfordres gennem analyser og drøftelser, og at brugen af IRIS Connects dataindsamlings- og...

  5. Report printer (COBOL IRIS 50)

    International Nuclear Information System (INIS)

    Paul, Daniele

    1973-10-01

    The research thesis reports a detailed study of the Report Writer of the COBOL language in order to integrate it into the IRIS 50 COBOL compiler. In order to use existing compiler processing, the author developed a simulation of the Report Writer by using Cobol statements generated in the declarative part of the Division procedure. After a brief presentation of the IRIS 50 computer, the author presents the general plan of the compiler with modifications and adjunctions exclusively due to the Report Writer. The next part addresses the practical implementation and the problems met and solved during this implementation

  6. What Genes Tell about Iris Appearance

    DEFF Research Database (Denmark)

    Harder, Stine; Christoffersen, Susanne R.; Johansen, Peter

    2012-01-01

    Predicting phenotypes based on genotypes is generally hard, but has shown good results for prediction of iris color. We propose to correlate the appearance of iris with DNA. Six single-nucleotide polymorphisms (SNPs) have previously been shown to correlate with human iris color, and we demonstrat...

  7. Iris features-based heart disease diagnosis by computer vision

    Science.gov (United States)

    Nguchu, Benedictor A.; Li, Li

    2017-07-01

    The study takes advantage of several new breakthroughs in computer vision technology to develop a new mid-irisbiomedical platform that processes iris image for early detection of heart-disease. Guaranteeing early detection of heart disease provides a possibility of having non-surgical treatment as suggested by biomedical researchers and associated institutions. However, our observation discovered that, a clinical practicable solution which could be both sensible and specific for early detection is still lacking. Due to this, the rate of majority vulnerable to death is highly increasing. The delayed diagnostic procedures, inefficiency, and complications of available methods are the other reasons for this catastrophe. Therefore, this research proposes the novel IFB (Iris Features Based) method for diagnosis of premature, and early stage heart disease. The method incorporates computer vision and iridology to obtain a robust, non-contact, nonradioactive, and cost-effective diagnostic tool. The method analyzes abnormal inherent weakness in tissues, change in color and patterns, of a specific region of iris that responds to impulses of heart organ as per Bernard Jensen-iris Chart. The changes in iris infer the presence of degenerative abnormalities in heart organ. These changes are precisely detected and analyzed by IFB method that includes, tensor-based-gradient(TBG), multi orientations gabor filters(GF), textural oriented features(TOF), and speed-up robust features(SURF). Kernel and Multi class oriented support vector machines classifiers are used for classifying normal and pathological iris features. Experimental results demonstrated that the proposed method, not only has better diagnostic performance, but also provides an insight for early detection of other diseases.

  8. A giant traumatic iris cyst

    Directory of Open Access Journals (Sweden)

    Lott Pooi Wah

    2015-12-01

    Full Text Available A 52 year-old construction worker presented with progressive painful blurring of vision in the left eye associated with redness for past 1 month. There was a history of penetrating injury in the same eye 10 years ago and he underwent primary wound toilet and suturing, lens removal with intraocular lens implantation. Slit lamp examination revealed a corneal scar at 9’oclock, a large transilluminant iris cyst superotemporally and adherent to corneal endothelium. It was extended from angle of the pupil and obstructing the visual axis. The patient underwent excision of an iris cyst through superior limbal incision. Viscodissection was done to separate the cyst from the corneal endothelium and underlying iris stroma. Trypan blue ophthalmic solution was injected into the cyst to stain the cyst capsule. Post operatively 7 days, vision improved to 6/7.5 without complication. There was no recurrence up to 1 year postoperation. Histopathological finding revealed a benign cyst mass lined by simple cuboidal to nonkeratinized stratified squamous epithelium. We had achieved a good surgical outcome with no complication to date for our case study. We advocate this modified surgical method to completely remove iris cyst.

  9. IRIS Nuclear Power Plant design

    International Nuclear Information System (INIS)

    Carelli, M. D.; Cobian, J.

    2002-01-01

    IRIS(International Reactor Innovative and Secure) is a novel light water reactor with a modular, integral primary system configuration. This concept, initially developed in response to the first NERI solicitation, is now being pursued by an international consortium of 20 participants from seven countries. IRIS is designed to satisfy the four key requirements for Generation IV systems: enhanced safety, improved economics, proliferation resistance and waste minimization. Its main features are: small-to-medium power (100-335 MWe/module); long life core 5 to 10 years) without shuffling or refueling; optimized maintenance with repair shutdown intervals of a least four years; simplified compact design with the primary vessel housing steam generators, pressurizer and pumps; safety by design where accidents are positively eliminated by design rather than engineering to cope with their consequences; loss of coolant accidents of any size and loss of low accidents are eliminated as major safety concerns; estimated power generation total cost is projected to be competitive with other power options. IRIS is one of four new reactor designs currently under NRC review. Projected schedule calls for design certification by 2008 and being ready for deployment by 2001 or later. This rather short schedule is made possible by the fact that IRIS is based on proven light water technology and new technology development is not required. (Author)

  10. Dynamic Features for Iris Recognition.

    Science.gov (United States)

    da Costa, R M; Gonzaga, A

    2012-08-01

    The human eye is sensitive to visible light. Increasing illumination on the eye causes the pupil of the eye to contract, while decreasing illumination causes the pupil to dilate. Visible light causes specular reflections inside the iris ring. On the other hand, the human retina is less sensitive to near infra-red (NIR) radiation in the wavelength range from 800 nm to 1400 nm, but iris detail can still be imaged with NIR illumination. In order to measure the dynamic movement of the human pupil and iris while keeping the light-induced reflexes from affecting the quality of the digitalized image, this paper describes a device based on the consensual reflex. This biological phenomenon contracts and dilates the two pupils synchronously when illuminating one of the eyes by visible light. In this paper, we propose to capture images of the pupil of one eye using NIR illumination while illuminating the other eye using a visible-light pulse. This new approach extracts iris features called "dynamic features (DFs)." This innovative methodology proposes the extraction of information about the way the human eye reacts to light, and to use such information for biometric recognition purposes. The results demonstrate that these features are discriminating features, and, even using the Euclidean distance measure, an average accuracy of recognition of 99.1% was obtained. The proposed methodology has the potential to be "fraud-proof," because these DFs can only be extracted from living irises.

  11. IRIS Final Technical Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    M. D. Carelli

    2003-11-03

    OAK-B135 This NERI project, originally started as the Secure Transportable Autonomous Light Water Reactor (STAR-LW) and currently known as the International Reactor Innovative and Secure (IRIS) project, had the objective of investigating a novel type of water-cooled reactor to satisfy the Generation IV goals: fuel cycle sustainability, enhanced reliability and safety, and improved economics. The research objectives over the three-year (1999-2002) program were as follows: First year: Assess various design alternatives and establish main characteristics of a point design; Second year: Perform feasibility and engineering assessment of the selected design solutions; Third year: Complete reactor design and performance evaluation, including cost assessment These objectives were fully attained and actually they served to launch IRIS as a full fledged project for eventual commercial deployment. The program did not terminate in 2002 at the end of the NERI program, and has just entered in its fifth year. This has been made possible by the IRIS project participants which have grown from the original four member, two-countries team to the current twenty members, nine countries consortium. All the consortium members work under their own funding and it is estimated that the value of their in-kind contributions over the life of the project has been of the order of $30M. Currently, approximately 100 people worldwide are involved in the project. A very important constituency of the IRIS project is the academia: 7 universities from four countries are members of the consortium and five more US universities are associated via parallel NERI programs. To date, 97 students have worked or are working on IRIS; 59 IRIS-related graduate theses have been prepared or are in preparation, and 41 of these students have already graduated with M.S. (33) or Ph.D. (8) degrees. This ''final'' report (final only as far as the NERI program is concerned) summarizes the work performed

  12. Small incision guarded hydroaspiration of iris lesions.

    Science.gov (United States)

    Singh, Arun D

    2017-11-01

    To describe the technique and results of a minimally invasive surgical technique for resection of small iris lesions. Consecutive case series of 22 patients with localised, small iris lesions that were resected using the described surgical technique that composed of multiple, small corneal incisions created to allow for internal iris resection with 23-gauge horizontal vitrectomy scissors, followed by guarded tumour aspiration through a clear plastic tubing (diameter 3.5 mm) primed with viscoelastic agent. The mean largest basal diameter was 3.0 mm (range 1.5-5.0 mm; median 3.0 mm) and mean thickness was 1.3 mm (range 0.5-2.5 mm; median 1.0 mm). Use of multiple (2-4) small corneal incisions (range 2.0-3.0 mm; mean 2.8 mm) allowed reduced postoperative morbidity (significant hyphema (0%), hypotony (0%), wound leak (0%), >2 line change in best corrected visual acuity at postoperative 1 week (4.5%) and mean corneal astigmatism of 1.0 D (range 0.14-2.99 D; median 0.8 D) at postoperative 4-12 weeks. The tumour could be resected with clear surgical margins in all neoplastic cases (benign (2), borderline (1) and malignant (16)). Local recurrence or metastases were not observed in any melanoma case over a mean follow-up of 33.0 months (range 1.0-90.0 months; median 33.5 months). Small incision guarded hydroaspiration is a minimally invasive surgical technique for resection of select small iris lesions. Use of multiple small corneal incisions avoids morbidity associated with a single large corneoscleral incision, and use of guarded aspiration may eliminate the risk of wound contamination by the malignant tumour. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Development of a quantitative assessment method of pigmentary skin disease using ultraviolet optical imaging.

    Science.gov (United States)

    Lee, Onseok; Park, Sunup; Kim, Jaeyoung; Oh, Chilhwan

    2017-11-01

    The visual scoring method has been used as a subjective evaluation of pigmentary skin disorders. Severity of pigmentary skin disease, especially melasma, is evaluated using a visual scoring method, the MASI (melasma area severity index). This study differentiates between epidermal and dermal pigmented disease. The study was undertaken to determine methods to quantitatively measure the severity of pigmentary skin disorders under ultraviolet illumination. The optical imaging system consists of illumination (white LED, UV-A lamp) and image acquisition (DSLR camera, air cooling CMOS CCD camera). Each camera is equipped with a polarizing filter to remove glare. To analyze images of visible and UV light, images are divided into frontal, cheek, and chin regions of melasma patients. Each image must undergo image processing. To reduce the curvature error in facial contours, a gradient mask is used. The new method of segmentation of front and lateral facial images is more objective for face-area-measurement than the MASI score. Image analysis of darkness and homogeneity is adequate to quantify the conventional MASI score. Under visible light, active lesion margins appear in both epidermal and dermal melanin, whereas melanin is found in the epidermis under UV light. This study objectively analyzes severity of melasma and attempts to develop new methods of image analysis with ultraviolet optical imaging equipment. Based on the results of this study, our optical imaging system could be used as a valuable tool to assess the severity of pigmentary skin disease. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Molecular Etiology of Hereditary Single-Side Deafness: Its Association With Pigmentary Disorders and Waardenburg Syndrome.

    Science.gov (United States)

    Kim, Shin Hye; Kim, Ah Reum; Choi, Hyun Seok; Kim, Min Young; Chun, Eun Hi; Oh, Seung-Ha; Choi, Byung Yoon

    2015-10-01

    Unilateral sensorineural hearing loss (USNHL)/single-side deafness (SSD) is a frequently encountered disability in children. The etiology of a substantial portion of USNHL/SSD still remains unknown, and genetic causes have not been clearly elucidated. In this study, the authors evaluated the heritability of USNHL/SSD.The authors sequentially recruited 50 unrelated children with SSD. For an etiologic diagnosis, we performed a rigorous review on the phenotypes of family members of all children and conducted, if necessary, molecular genetic tests including targeted exome sequencing of 129 deafness genes.Among the 50 SSD children cohort, the authors identify 4 (8%) unrelated SSD probands from 4 families (SH136, SB173, SB177, and SB199) with another hearing impaired family members. Notably, all 4 probands in our cohort with a familial history of SSD also have pigmentary abnormalities such as brown freckles or premature gray hair within first degree relatives, which may indicate that genes whose products are involved with pigmentary disorder could be candidates for heritable SSD. Indeed, SH136 and SB199 turned out to segregate a mutation in MITF and PAX3, respectively, leading to a molecular diagnosis of Waardenburg syndrome (WS).We report, for the first time in the literature, a significant heritability of pediatric SSD. There is a strong association between the heritability of USNHL/SSD and the pigmentary abnormality, shedding a new light on the understanding of the molecular basis of heritable USNHL/SSD. In case of children with congenital SSD, it would be mandatory to rigorously screen pigmentary abnormalities. WS should also be included in the differential diagnosis of children with USNHL/SSD, especially in a familial form.

  15. Pigment Dispersion Syndrome Progression to Pigmentary Glaucoma in a Latin American Population

    OpenAIRE

    Gomez Goyeneche, Hector Fernando; Hernandez-Mendieta, Diana Patricia; Rodriguez, Diego Andres; Sepulveda, Ana Irene; Toledo, Jose Daniel

    2016-01-01

    ABSTRACT Objective: To determine the progression of pigment dispersion syndrome (PDS) into pigmentary glaucoma (PG) in a population at the Central Military Hospital in Bogot?, Colombia. Materials and methods: A retrospective study was conducted, based on a review of medical records of patients with PDS evaluated in the Glaucoma Clinic. Data were collected in a database in excel and subsequently analyzed with the software Statistical Package for the Social Sciences (SPSS), performing Chi-squar...

  16. Secondary pigmentary glaucoma in patients with underlying primary pigment dispersion syndrome

    OpenAIRE

    Sivaraman, Kavitha R; Patel, Chirag G; Vajaranant, Thasarat S; Aref, Ahmad A

    2013-01-01

    Kavitha R Sivaraman, Chirag G Patel, Thasarat S Vajaranant, Ahmad A ArefDepartment of Ophthalmology and Visual Sciences, Illinois Eye and Ear Infirmary, University of Illinois at Chicago School of Medicine, Chicago, IL, USAAbstract: Primary pigment dispersion syndrome (PPDS) is a bilateral condition that occurs in anatomically predisposed individuals. PPDS may evolve into pigmentary glaucoma, but it is difficult to predict which patients will progress. Secondary pigment dispersion is more oft...

  17. Estimating the attributable fraction for melanoma: a meta-analysis of pigmentary characteristics and freckling.

    Science.gov (United States)

    Olsen, Catherine M; Carroll, Heidi J; Whiteman, David C

    2010-11-15

    Epidemiologic research has demonstrated convincingly that certain pigmentary characteristics are associated with increased relative risks of melanoma; however there has been no comprehensive review to rank these characteristics in order of their importance on a population level. We conducted a systematic review of the literature and meta-analysis to quantify the contribution of pigmentary characteristics to melanoma, estimated by the population-attributable fraction (PAF). Eligible studies were those that permitted quantitative assessment of the association between histologically confirmed melanoma and hair colour, eye colour, skin phototype and presence of freckling; we identified 66 such studies using citation databases, followed by manual review of retrieved references. We calculated summary relative risks using weighted averages of the log RR, taking into account random effects, and used these to estimate the PAF. The pooled RRs for pigmentary characteristics were: 2.64 for red/red-blond, 2.0 for blond and 1.46 for light brown hair colour (vs. dark); 1.57 for blue/blue-grey and 1.51 for green/grey/hazel eye colour (vs. dark); 2.27, 1.99 and 1.35 for skin phototypes I, II and III respectively (vs. IV); and 1.99 for presence of freckling. The highest PAFs were observed for skin phototypes 1/II (0.27), presence of freckling (0.23), and blond hair colour (0.23). For eye colour, the PAF for blue/blue-grey eye colour was higher than for green/grey/hazel eye colour (0.18 vs. 0.13). The PAF of melanoma associated with red hair colour was 0.10. These estimates of melanoma burden attributable to pigmentary characteristics provide a basis for designing prevention strategies for melanoma.

  18. Iris reconstruction using artificial iris prosthesis for management of aniridia.

    Science.gov (United States)

    Mostafa, Yehia S; Osman, Amr A; Hassanein, Dina H; Zeid, Ashraf M; Sherif, Ahmed M

    2018-01-01

    To discuss the limitations and benefits of the BrightOcular prosthetic artificial iris device in management of aniridia associated with aphakia or cataract. This is a retrospective study including 5 eyes of 4 patients who underwent implantation of the BrightOcular iris prosthesis (Stellar Devices) for total or partial aniridia. The cases included 2 eyes of 1 patient with congenital aniridia associated with congenital cataract and 3 eyes with traumatic aniridia: 1 with subluxated cataractous lens and 2 with aphakia. In all cases, the iris prosthesis was implanted after a 3-piece acrylic intraocular lens was implanted. We evaluated the clinical course with a minimum follow-up period of 6 months, the intraoperative and postoperative complications, and the cosmetic satisfaction of patients. All patients had improved uncorrected distance visual acuity and best-corrected distance visual acuity. All patients had a transient corneal edema that resolved within the first postoperative week. Only the patient with congenital aniridia had a permanent increase in intraocular pressure and developed a band keratopathy throughout a 2-year follow-up period. The prosthesis was well-centered in all eyes except for one case that required scleral suture fixation after 3 months. All patients had a satisfactory cosmetic appearance. BrightOcular iris prosthesis is a safe and useful tool to correct aniridia associated with pseudophakia or aphakia. Being foldable, it is easy to be implanted through a small incision and placed in the ciliary sulcus without sutures when properly sized. Cosmetic results are satisfactory. Sizing methods should be improved.

  19. Ultrasound biomicroscopy and iris pigment dispersion: a case--control study.

    Science.gov (United States)

    Mora, P; Sangermani, C; Ghirardini, S; Carta, A; Ungaro, N; Gandolfi, Sa

    2010-04-01

    The study involved eyes affected by pigment dispersion syndrome (PDS) or pigmentary glaucoma (PG) investigated by ultrasound biomicroscopy (UBM). Different irido-corneal parameters were assessed and compared with those from healthy controls. The aim was to investigate the capacity of the UBM in differentiating the cases and, potentially, in confirming the pathogenic mechanisms. Patients with a first diagnosis of PDS or PG were included. A cohort of healthy volunteers matched for sex, age and refractive errors was recruited. All underwent UBM examination: the following parameters were assessed in relaxed and stimulated accommodative state in one eye: iris-lens contact (ILC), irido-corneal angle (ICA) and iris concavity (IC). A receiver operating characteristic (ROC) analysis assessed the ability of UBM to discriminate between subjects with and without PDS/PG. There were 24 eyes in the case group: four diagnosed as PG and the remaining 20 as PDS. There were 25 eyes in the control group. The two groups were statistically superimposable except for baseline intraocular pressure, which was higher in the case group (p=0.0001). All UBM parameters were statistically different between the two groups. ICA in near vision was the best-performing parameter, reaching a sensitivity (=specificity) of 0.875 with a cut-off at 53.0 degrees . The second most sensitive parameter was IC, still in near vision. All UBM parameters examined were statistically different between the two groups. ROC analysis showed ICA and IC in near vision to be the most discriminatory parameters. This evidence confirms the importance of iris movements in inducing the particular features of PDS/PG.

  20. Fluid and structure coupling analysis of the interaction between aqueous humor and iris.

    Science.gov (United States)

    Wang, Wenjia; Qian, Xiuqing; Song, Hongfang; Zhang, Mindi; Liu, Zhicheng

    2016-12-28

    Glaucoma is the primary cause of irreversible blindness worldwide associated with high intraocular pressure (IOP). Elevated intraocular pressure will affect the normal aqueous humor outflow, resulting in deformation of iris. However, the deformation ability of iris is closely related to its material properties. Meanwhile, the passive deformation of the iris aggravates the pupillary block and angle closure. The nature of the interaction mechanism of iris deformation and aqueous humor fluid flow has not been fully understood and has been somewhat a controversial issue. The purpose here was to study the effect of IOP, localization, and temperature on the flow of the aqueous humor and the deformation of iris interacted by aqueous humor fluid flow. Based on mechanisms of aqueous physiology and fluid dynamics, 3D model of anterior chamber (AC) was constructed with the human anatomical parameters as a reference. A 3D idealized standard geometry of anterior segment of human eye was performed. Enlarge the size of the idealization geometry model 5 times to create a simulation device by using 3D printing technology. In this paper, particle image velocimetry technology is applied to measure the characteristic of fluid outflow in different inlet velocity based on the device. Numerically calculations were made by using ANSYS 14.0 Finite Element Analysis. Compare of the velocity distributions to confirm the validity of the model. The fluid structure interaction (FSI) analysis was carried out in the valid geometry model to study the aqueous flow and iris change. In this paper, the validity of the model is verified through computation and comparison. The results indicated that changes of gravity direction of model significantly affected the fluid dynamics parameters and the temperature distribution in anterior chamber. Increased pressure and the vertical position increase the velocity of the aqueous humor fluid flow, with the value increased of 0.015 and 0.035 mm/s. The results

  1. Lentes plegables suturadas a iris

    Directory of Open Access Journals (Sweden)

    Dunia Cruz Izquierdo

    Full Text Available Para la corrección quirúrgica de la afaquia existen en la actualidad varias técnicas quirúrgicas que permiten fijar los lentes intraoculares plegables o rígidos en cámara posterior suturados al iris o al sulcus ciliar. En estas circunstancias el cirujano determinará cuándo, dónde y el tipo de lente mejor a implantar. Se presenta un paciente con una afaquia traumática del ojo izquierdo, con agudeza visual sin corrección de movimiento de mano a 1 m. Se le realizó implante secundario de lente intraocular plegable de cámara posterior suturada al iris. En el examen biomicroscópico en lámpara de hendidura del ojo izquierdo se observó midriasis media paralítica, refracción dinámica de +11,00 (0,6 y tensión ocular normal. Se le realizó examen por bimicroscopía indirecta sin alteración. Al mes de operado la agudeza visual mejor corregida alcanzó la unidad de visión. Las complicaciones presentadas fueron ovalización de la pupila y depósitos de pigmentos de iris en el lente intraocular.

  2. DCT-based iris recognition.

    Science.gov (United States)

    Monro, Donald M; Rakshit, Soumyadip; Zhang, Dexin

    2007-04-01

    This paper presents a novel iris coding method based on differences of discrete cosine transform (DCT) coefficients of overlapped angular patches from normalized iris images. The feature extraction capabilities of the DCT are optimized on the two largest publicly available iris image data sets, 2,156 images of 308 eyes from the CASIA database and 2,955 images of 150 eyes from the Bath database. On this data, we achieve 100 percent Correct Recognition Rate (CRR) and perfect Receiver-Operating Characteristic (ROC) Curves with no registered false accepts or rejects. Individual feature bit and patch position parameters are optimized for matching through a product-of-sum approach to Hamming distance calculation. For verification, a variable threshold is applied to the distance metric and the False Acceptance Rate (FAR) and False Rejection Rate (FRR) are recorded. A new worst-case metric is proposed for predicting practical system performance in the absence of matching failures, and the worst case theoretical Equal Error Rate (EER) is predicted to be as low as 2.59 x 10(-4) on the available data sets.

  3. PLATEAU IRIS – DIAGNOSIS AND TREATMENT

    Science.gov (United States)

    Stefan, Cornel; Iliescu, Daniela Adriana; Batras, Mehdi; Timaru, Cristina Mihaela; De Simone, Algerino

    2015-01-01

    Objectives: The objective of our study was to review the current knowledge on the diagnosis and treatment options of plateau iris configuration and syndrome. Systematic review methodology: Relevant publications on plateau iris that were published until 2014. Conclusions: Plateau iris syndrome is a form of primary angle closure glaucoma caused by a large or anteriorly positioned ciliary body that leads to mechanical obstruction of trabecular meshwork. This condition is most often found in younger patients. Plateau iris has been considered an abnormal anatomic variant of the iris that can be diagnosed on ultrasound biomicroscopy or optical coherence tomography of anterior segment. Patients with plateau iris syndrome can be recognized by the lack of response in angle opening after iridotomy. The treatment of choice in these cases is argon laser peripheral iridoplasty PMID:27373109

  4. PLATEAU IRIS--DIAGNOSIS AND TREATMENT.

    Science.gov (United States)

    Stefan, Cornel; Iliescu, Daniela Adriana; Batras, Mehdi; Timaru, Cristina Mihaela; De Simone, Algerino

    2015-01-01

    The objective of our study was to review the current knowledge on the diagnosis and treatment options of plateau iris configuration and syndrome. Relevant publications on plateau iris that were published until 2014. Plateau iris syndrome is a form of primary angle closure glaucoma caused by a large or anteriorly positioned ciliary body that leads to mechanical obstruction of trabecular meshwork. This condition is most often found in younger patients. Plateau iris has been considered an abnormal anatomic variant of the iris that can be diagnosed on ultrasound biomicroscopy or optical coherence tomography of anterior segment. Patients with plateau iris syndrome can be recognized by the lack of response in angle opening after iridotomy. The treatment of choice in these cases is argon laser peripheral iridoplasty.

  5. Video-based noncooperative iris image segmentation.

    Science.gov (United States)

    Du, Yingzi; Arslanturk, Emrah; Zhou, Zhi; Belcher, Craig

    2011-02-01

    In this paper, we propose a video-based noncooperative iris image segmentation scheme that incorporates a quality filter to quickly eliminate images without an eye, employs a coarse-to-fine segmentation scheme to improve the overall efficiency, uses a direct least squares fitting of ellipses method to model the deformed pupil and limbic boundaries, and develops a window gradient-based method to remove noise in the iris region. A remote iris acquisition system is set up to collect noncooperative iris video images. An objective method is used to quantitatively evaluate the accuracy of the segmentation results. The experimental results demonstrate the effectiveness of this method. The proposed method would make noncooperative iris recognition or iris surveillance possible.

  6. Comparative analysis of classification based algorithms for diabetes diagnosis using iris images.

    Science.gov (United States)

    Samant, Piyush; Agarwal, Ravinder

    2018-01-01

    Photo-diagnosis is always an intriguing area for the researchers, with the advancement of image processing and computer machine vision techniques it have become more reliable and popular in recent years. The objective of this paper is to study the change in the features of iris, particularly irregularities in the pigmentation of certain areas of the iris with respect to diabetic health of an individual. Apart from the point that iris recognition concentrates on the overall structure of the iris, diagnostic techniques emphasises the local variations in the particular area of iris. Pre-image processing techniques have been applied to extract iris and thereafter, region of interest from the extracted iris have been cropped out. In order to observe the changes in the tissue pigmentation of region of interest, statistical, texture textural and wavelet features have been extracted. At the end, a comparison of accuracies of five different classifiers has been presented to classify two subject groups of diabetic and non-diabetic. Best classification accuracy has been calculated as 89.66% by the random forest classifier. Results have been shown the effectiveness and diagnostic significance of the proposed methodology. Presented piece of work offers a novel systemic perspective of non-invasive and automatic diabetic diagnosis.

  7. Iris analysis for biometric recognition systems

    CERN Document Server

    Bodade, Rajesh M

    2014-01-01

    The book presents three most significant areas in Biometrics and Pattern Recognition. A step-by-step approach for design and implementation of Dual Tree Complex Wavelet Transform (DTCWT) plus Rotated Complex Wavelet Filters (RCWF) is discussed in detail. In addition to the above, the book provides detailed analysis of iris images and two methods of iris segmentation. It also discusses simplified study of some subspace-based methods and distance measures for iris recognition backed by empirical studies and statistical success verifications.

  8. Exploring the feasibility of iris recognition for visible spectrum iris images obtained using smartphone camera

    Science.gov (United States)

    Trokielewicz, Mateusz; Bartuzi, Ewelina; Michowska, Katarzyna; Andrzejewska, Antonina; Selegrat, Monika

    2015-09-01

    In the age of modern, hyperconnected society that increasingly relies on mobile devices and solutions, implementing a reliable and accurate biometric system employing iris recognition presents new challenges. Typical biometric systems employing iris analysis require expensive and complicated hardware. We therefore explore an alternative way using visible spectrum iris imaging. This paper aims at answering several questions related to applying iris biometrics for images obtained in the visible spectrum using smartphone camera. Can irides be successfully and effortlessly imaged using a smartphone's built-in camera? Can existing iris recognition methods perform well when presented with such images? The main advantage of using near-infrared (NIR) illumination in dedicated iris recognition cameras is good performance almost independent of the iris color and pigmentation. Are the images obtained from smartphone's camera of sufficient quality even for the dark irides? We present experiments incorporating simple image preprocessing to find the best visibility of iris texture, followed by a performance study to assess whether iris recognition methods originally aimed at NIR iris images perform well with visible light images. To our best knowledge this is the first comprehensive analysis of iris recognition performance using a database of high-quality images collected in visible light using the smartphones flashlight together with the application of commercial off-the-shelf (COTS) iris recognition methods.

  9. Iris Recognition: The Consequences of Image Compression

    Directory of Open Access Journals (Sweden)

    Bishop DanielA

    2010-01-01

    Full Text Available Iris recognition for human identification is one of the most accurate biometrics, and its employment is expanding globally. The use of portable iris systems, particularly in law enforcement applications, is growing. In many of these applications, the portable device may be required to transmit an iris image or template over a narrow-bandwidth communication channel. Typically, a full resolution image (e.g., VGA is desired to ensure sufficient pixels across the iris to be confident of accurate recognition results. To minimize the time to transmit a large amount of data over a narrow-bandwidth communication channel, image compression can be used to reduce the file size of the iris image. In other applications, such as the Registered Traveler program, an entire iris image is stored on a smart card, but only 4 kB is allowed for the iris image. For this type of application, image compression is also the solution. This paper investigates the effects of image compression on recognition system performance using a commercial version of the Daugman iris2pi algorithm along with JPEG-2000 compression, and links these to image quality. Using the ICE 2005 iris database, we find that even in the face of significant compression, recognition performance is minimally affected.

  10. Iris Recognition: The Consequences of Image Compression

    Science.gov (United States)

    Ives, Robert W.; Bishop, Daniel A.; Du, Yingzi; Belcher, Craig

    2010-12-01

    Iris recognition for human identification is one of the most accurate biometrics, and its employment is expanding globally. The use of portable iris systems, particularly in law enforcement applications, is growing. In many of these applications, the portable device may be required to transmit an iris image or template over a narrow-bandwidth communication channel. Typically, a full resolution image (e.g., VGA) is desired to ensure sufficient pixels across the iris to be confident of accurate recognition results. To minimize the time to transmit a large amount of data over a narrow-bandwidth communication channel, image compression can be used to reduce the file size of the iris image. In other applications, such as the Registered Traveler program, an entire iris image is stored on a smart card, but only 4 kB is allowed for the iris image. For this type of application, image compression is also the solution. This paper investigates the effects of image compression on recognition system performance using a commercial version of the Daugman iris2pi algorithm along with JPEG-2000 compression, and links these to image quality. Using the ICE 2005 iris database, we find that even in the face of significant compression, recognition performance is minimally affected.

  11. Computational cameras for moving iris recognition

    Science.gov (United States)

    McCloskey, Scott; Venkatesha, Sharath

    2015-05-01

    Iris-based biometric identification is increasingly used for facility access and other security applications. Like all methods that exploit visual information, however, iris systems are limited by the quality of captured images. Optical defocus due to a small depth of field (DOF) is one such challenge, as is the acquisition of sharply-focused iris images from subjects in motion. This manuscript describes the application of computational motion-deblurring cameras to the problem of moving iris capture, from the underlying theory to system considerations and performance data.

  12. Plateau iris Íris em platô

    Directory of Open Access Journals (Sweden)

    Alberto Diniz Filho

    2008-10-01

    Full Text Available The term plateau iris was first coined in 1958 to describe the iris configuration of a patient. Two years later the concept of plateau iris was published. In 1977, the plateau iris configuration was classically defined as presurgical changes of an eye with a relative normal central anterior chamber depth, flat iris by conventional biomicroscopy, but displaying an extremely narrow or closed angle on gonioscopic examination. On the other hand, the plateau iris syndrome was defined as an acute glaucoma crisis in one eye with a relative normal central anterior chamber depth and patent iridotomy on direct examination, presenting angle closure confirmed by gonioscopic examination after mydriasis. In 1992, the anatomic aspects of plateau iris were studied using ultrasound biomicroscopy. Finally, plateau iris has been considered an anatomic variant of iris structure in which the iris periphery angulates sharply forward from its insertion point and then again angulates sharply and centrally backward, along with an anterior positioning of the ciliary processes seen on ultrasound biomicroscopy. The clinical treatment of plateau iris syndrome is carried out with topical use of pilocarpine. However, the definitive treatment should be fulfilled by performing an argon laser peripheral iridoplasty.O termo íris em platô foi primeiramente inventado em 1958 para descrever a configuração da íris de um paciente. Dois anos depois o conceito de íris em platô foi publicado. Em 1977, a configuração de íris em platô foi classicamente definida como alterações pré-cirúrgicas de um olho com uma profundidade de câmara anterior relativamente normal, íris plana pela biomicroscopia convencional, mas mostrando um ângulo extremamente estreito ou fechado pela gonioscopia. Por outro lado, a síndrome de íris em platô foi definida como uma crise de glaucoma agudo em um olho com uma profundidade de câmara anterior relativamente normal e uma iridectomia patente ao

  13. Multiple local feature representations and their fusion based on an SVR model for iris recognition using optimized Gabor filters

    Science.gov (United States)

    He, Fei; Liu, Yuanning; Zhu, Xiaodong; Huang, Chun; Han, Ye; Dong, Hongxing

    2014-12-01

    Gabor descriptors have been widely used in iris texture representations. However, fixed basic Gabor functions cannot match the changing nature of diverse iris datasets. Furthermore, a single form of iris feature cannot overcome difficulties in iris recognition, such as illumination variations, environmental conditions, and device variations. This paper provides multiple local feature representations and their fusion scheme based on a support vector regression (SVR) model for iris recognition using optimized Gabor filters. In our iris system, a particle swarm optimization (PSO)- and a Boolean particle swarm optimization (BPSO)-based algorithm is proposed to provide suitable Gabor filters for each involved test dataset without predefinition or manual modulation. Several comparative experiments on JLUBR-IRIS, CASIA-I, and CASIA-V4-Interval iris datasets are conducted, and the results show that our work can generate improved local Gabor features by using optimized Gabor filters for each dataset. In addition, our SVR fusion strategy may make full use of their discriminative ability to improve accuracy and reliability. Other comparative experiments show that our approach may outperform other popular iris systems.

  14. Iris Image Classification Based on Hierarchical Visual Codebook.

    Science.gov (United States)

    Zhenan Sun; Hui Zhang; Tieniu Tan; Jianyu Wang

    2014-06-01

    Iris recognition as a reliable method for personal identification has been well-studied with the objective to assign the class label of each iris image to a unique subject. In contrast, iris image classification aims to classify an iris image to an application specific category, e.g., iris liveness detection (classification of genuine and fake iris images), race classification (e.g., classification of iris images of Asian and non-Asian subjects), coarse-to-fine iris identification (classification of all iris images in the central database into multiple categories). This paper proposes a general framework for iris image classification based on texture analysis. A novel texture pattern representation method called Hierarchical Visual Codebook (HVC) is proposed to encode the texture primitives of iris images. The proposed HVC method is an integration of two existing Bag-of-Words models, namely Vocabulary Tree (VT), and Locality-constrained Linear Coding (LLC). The HVC adopts a coarse-to-fine visual coding strategy and takes advantages of both VT and LLC for accurate and sparse representation of iris texture. Extensive experimental results demonstrate that the proposed iris image classification method achieves state-of-the-art performance for iris liveness detection, race classification, and coarse-to-fine iris identification. A comprehensive fake iris image database simulating four types of iris spoof attacks is developed as the benchmark for research of iris liveness detection.

  15. Improvements and new features in the IRI-2000 model

    International Nuclear Information System (INIS)

    Bilitza, D.

    2002-01-01

    This paper describes the changes that were implemented in the new version of the COSPAR/URSI International Reference Ionosphere (IRI-2000). These changes are: (1) two new options for the electron density in the D-region, (2) a better functional description of the electron density in the E-F merging region, (3) inclusion of the F1 layer occurrence probability as a new parameter, (4) a new model for the bottomside parameters B 0 and B 1 that greatly improves the representation at low and equatorial latitudes during high solar activities, (5) inclusion of a model for foF2 storm-time updating, (6) a new option for the electron temperature in the topside ionosphere, and (7) inclusion of a model for the equatorial F region ion drift. The main purpose of this paper is to provide the IRI users with examples of the effects of these changes. (author)

  16. [Surgical treatment with an artificial iris].

    Science.gov (United States)

    Mayer, C S; Hoffmann, A E

    2015-10-01

    Iris defects with their disturbed pupillary function, visual impairment and glare constitute a therapeutic challenge in surgical reconstruction. A new therapeutic option for distinctive defects consists in the implantation of a custom-made silicone iris. This new and challenging therapy provides the opportunity to achieve an individual, aesthetically appealing and good functional result for the patient.

  17. Feature Set Fusion for Spoof Iris Detection

    Directory of Open Access Journals (Sweden)

    P. V. L. Suvarchala

    2018-04-01

    Full Text Available Iris recognition is considered as one of the most promising noninvasive biometric systems providing automated human identification. Numerous programs, like unique ID program in India - Aadhar, include iris biometric to provide distinctive identity identification to citizens. The active area is usually captured under non ideal imaging conditions. It usually suffers from poor brightness, low contrast, blur due to camera or subject's relative movement and eyelid eyelash occlusions. Besides the technical challenges, iris recognition started facing sophisticated threats like spoof attacks. Therefore it is vital that the integrity of such large scale iris deployments must be preserved. This paper presents the development of a new spoof resistant approach which exploits the statistical dependencies of both general eye and localized iris regions in textural domain using spatial gray level dependence matrix (SGLDM, gray level run length matrix (GLRLM and contourlets in transform domain. We did experiments on publicly available fake and lens iris image databases. Correct classification rate obtained with ATVS-FIr iris database is 100% while it is 95.63% and 88.83% with IITD spoof iris databases respectively.

  18. [Electronic Device for Retinal and Iris Imaging].

    Science.gov (United States)

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  19. Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.

    Science.gov (United States)

    Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat

    2016-10-01

    To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.

  20. Enhanced iris recognition method based on multi-unit iris images

    Science.gov (United States)

    Shin, Kwang Yong; Kim, Yeong Gon; Park, Kang Ryoung

    2013-04-01

    For the purpose of biometric person identification, iris recognition uses the unique characteristics of the patterns of the iris; that is, the eye region between the pupil and the sclera. When obtaining an iris image, the iris's image is frequently rotated because of the user's head roll toward the left or right shoulder. As the rotation of the iris image leads to circular shifting of the iris features, the accuracy of iris recognition is degraded. To solve this problem, conventional iris recognition methods use shifting of the iris feature codes to perform the matching. However, this increases the computational complexity and level of false acceptance error. To solve these problems, we propose a novel iris recognition method based on multi-unit iris images. Our method is novel in the following five ways compared with previous methods. First, to detect both eyes, we use Adaboost and a rapid eye detector (RED) based on the iris shape feature and integral imaging. Both eyes are detected using RED in the approximate candidate region that consists of the binocular region, which is determined by the Adaboost detector. Second, we classify the detected eyes into the left and right eyes, because the iris patterns in the left and right eyes in the same person are different, and they are therefore considered as different classes. We can improve the accuracy of iris recognition using this pre-classification of the left and right eyes. Third, by measuring the angle of head roll using the two center positions of the left and right pupils, detected by two circular edge detectors, we obtain the information of the iris rotation angle. Fourth, in order to reduce the error and processing time of iris recognition, adaptive bit-shifting based on the measured iris rotation angle is used in feature matching. Fifth, the recognition accuracy is enhanced by the score fusion of the left and right irises. Experimental results on the iris open database of low-resolution images showed that the

  1. A mitochondrial tRNA(His) gene mutation causing pigmentary retinopathy and neurosensorial deafness.

    Science.gov (United States)

    Crimi, M; Galbiati, S; Perini, M P; Bordoni, A; Malferrari, G; Sciacco, M; Biunno, I; Strazzer, S; Moggio, M; Bresolin, N; Comi, G P

    2003-04-08

    We have identified a heteroplasmic G to A mutation at position 12,183 of the mitochondrial transfer RNA Histidine (tRNA(His)) gene in three related patients. These phenotypes varied according to mutation heteroplasmy: one had severe pigmentary retinopathy, neurosensorial deafness, testicular dysfunction, muscle hypotrophy, and ataxia; the other two had only retinal and inner ear involvement. The mutation is in a highly conserved region of the T(psi)C stem of the tRNA(His) gene and may alter secondary structure formation. This is the first described pathogenic, maternally inherited mutation of the mitochondrial tRNA(His) gene.

  2. Molecular Genetics of Pigment Dispersion Syndrome and Pigmentary Glaucoma: New Insights into Mechanisms.

    Science.gov (United States)

    Lahola-Chomiak, Adrian A; Walter, Michael A

    2018-01-01

    We explore the ideas and advances surrounding the genetic basis of pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG). As PG is the leading cause of nontraumatic blindness in young adults and current tailored interventions have proven ineffective, a better understanding of the underlying causes of PDS, PG, and their relationship is essential. Despite PDS being a subclinical disease, a large proportion of patients progress to PG with associated vision loss. Decades of research have supported a genetic component both for PDS and conversion to PG. We review the body of evidence supporting a genetic basis in humans and animal models and reevaluate classical mechanisms of PDS/PG considering this new evidence.

  3. Efficient Iris Localization via Optimization Model

    Directory of Open Access Journals (Sweden)

    Qi Wang

    2017-01-01

    Full Text Available Iris localization is one of the most important processes in iris recognition. Because of different kinds of noises in iris image, the localization result may be wrong. Besides this, localization process is time-consuming. To solve these problems, this paper develops an efficient iris localization algorithm via optimization model. Firstly, the localization problem is modeled by an optimization model. Then SIFT feature is selected to represent the characteristic information of iris outer boundary and eyelid for localization. And SDM (Supervised Descent Method algorithm is employed to solve the final points of outer boundary and eyelids. Finally, IRLS (Iterative Reweighted Least-Square is used to obtain the parameters of outer boundary and upper and lower eyelids. Experimental result indicates that the proposed algorithm is efficient and effective.

  4. IRIS Toxicological Review of Tetrahydrofuran (THF) ...

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review of Tetrahydrofuran, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for tetrahydrofuran. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  5. Integrated electrochromic iris device for low power and space-limited applications

    International Nuclear Information System (INIS)

    Deutschmann, T; Oesterschulze, E

    2014-01-01

    We present a micro-electrooptical iris based on the electrochromic polymer poly(3,4-ethylenedioxythiophene). Two ring-shaped concentric polymer-segments embedded in a transparent electrochemical cell form the micro iris. The polymer layers change their absorption when an external voltage is applied. This iris device benefits from the absence of any mechanically moving part. This renders a very slim design possible, which is suited for small integrated camera systems. During operation the polymer maintains its absorbing state without power consumption. Its low driving voltage of maximum 1.5 V is beneficial for battery powered applications. The impact of the iris on the depth of focus and transmission control as well as its dynamical behavior will be addressed. (paper)

  6. Relationship of the Van Herick Grading System with Peripheral Iris Configuration and Level of Iris Insertion.

    Science.gov (United States)

    Khan, Faisal Aziz; Niazi, Shafaq Pervez Khan; Khan, Assad Zaman

    2017-09-01

    To determine the relationship of the van Herick angle grading system with the level of iris insertion and peripheral iris configuration. Observational study. Eye department, Combined Military Hospital, Malir Cantt., Karachi, from May to October 2015. Sixty-five eyes of 65 patients were recruited. Anterior chamber depth at the temporal limbus was measured as a fraction of corneal section thickness using van Herick technique and graded on the standard 4-point scale of the van Herick grading system. Gonioscopy of the temporal quadrant was performed with a Posner 4 mirror goniolens and both the true level of iris insertion and peripheral iris configuration were recorded on a 4-point scale so as to equate with the van Herick 4-point grading system. Spearman's rho test was applied to determine the relationship of the van Herick grading system with level of iris root insertion and peripheral iris configuration. Amoderate positive correlation between van Herick grade and peripheral iris configuration was found which was statistically significant (rs=0.42, p < 0.001). Astatistically significant and moderate positive correlation was also detected between van Herick grade and the level of iris insertion (rs=0.45, p < 0.001). The van Herick grade has a moderately positive relationship with the peripheral iris configuration and true level of iris insertion.

  7. Host cell reactivation by fibroblasts from patients with pigmentary degeneration of the retina

    International Nuclear Information System (INIS)

    Lytle, C.D.; Tarone, R.E.; Barrett, S.F.; Robbins, J.H.; Wirtschafter, J.D.; Dupuy, J.-M.

    1983-01-01

    Cockayne syndrome (CS) is an autosomal recessive disease characterized by numerous clinical abnormalities including acute sun sensitivity and primary pigmentary degeneration of the retina. Cultured fibroblasts from CS patients are hypersensitive to ultraviolet radiation. Host cell reactivation of irradiated virus was studied in CS and in other diseases with retinal degeneration to evaluate repair. The survival of UV-irradiated Herpes simplex virus type 1 was determined in fibroblast lines from four normal donors, two patients with CS, one with both xeroderma pigmentosum (XP) and CS, and from several other patients with (Usher syndrome, olivopontocerebellar atrophy, retinitis pigmentosa) and without (XP, ataxia telangiectasia) primary pigmentary degeneration of the retina. The viral survival curves in all cell lines showed two components: a very sensitive initial component followed by an exponential, less sensitive component. The exponential component had greater sensitivity than normal in the case of the CS patients, the patient with both XP and CS, and the XP patient. It was proposed that patients with CS have defective repair of DNA which may be the cause of their retinal degeneration. (author)

  8. Host cell reactivation by fibroblasts from patients with pigmentary degeneration of the retina

    Energy Technology Data Exchange (ETDEWEB)

    Lytle, C.D. (Food and Drug Administration, Rockville, MD (USA)); Tarone, R.E.; Barrett, S.F.; Robbins, J.H. (National Cancer Inst., Bethesda, MD (USA)); Wirtschafter, J.D. (Minnesota Univ., Minneapolis (USA). Hospitals); Dupuy, J.M. (Quebec Univ., Laval-des-Rapides (Canada). Inst. Armand-Frappier)

    1983-05-01

    Cockayne syndrome (CS) is an autosomal recessive disease characterized by numerous clinical abnormalities including acute sun sensitivity and primary pigmentary degeneration of the retina. Cultured fibroblasts from CS patients are hypersensitive to ultraviolet radiation. Host cell reactivation of irradiated virus was studied in CS and in other diseases with retinal degeneration to evaluate repair. The survival of UV-irradiated Herpes simplex virus type 1 was determined in fibroblast lines from four normal donors, two patients with CS, one with both xeroderma pigmentosum (XP) and CS, and from several other patients with (Usher syndrome, olivopontocerebellar atrophy, retinitis pigmentosa) and without (XP, ataxia telangiectasia) primary pigmentary degeneration of the retina. The viral survival curves in all cell lines showed two components: a very sensitive initial component followed by an exponential, less sensitive component. The exponential component had greater sensitivity than normal in the case of the CS patients, the patient with both XP and CS, and the XP patient. It was proposed that patients with CS have defective repair of DNA which may be the cause of their retinal degeneration.

  9. IRIS economics. A sensitivity review

    International Nuclear Information System (INIS)

    Miller, Keith

    2003-01-01

    IRIS (International Reactor Innovative and Secure) is a small to medium advanced light water cooled modular reactor being developed by an international consortium led by Westinghouse/BNFL. This reactor design is specifically aimed at utilities looking to install new (or replacement) nuclear capacity to match market demands, or at developing countries for their distributed power needs. To determine the optimal configuration for IRIS, analysis was undertaken to establish Generation Costs ($/MWh) and Internal Rate of Return (IRR %) to the Utility at alternative power ratings. This was then combined with global market projections for electricity demand out to 2030, segmented into key geographical regions. Finally this information is brought together to form insights, conclusions and recommendations regarding the optimal design. The resultant analysis reveals an optimum power rating for a single module of 335 MWe, with a construction period of 3 years or less and a minimum plant life of 60 years. Individual modules can be installed in a staggered fashion (3 equivalent to 1005 MWe) or built in pairs (2 sets of twin units' equivalent to 1340 MWe). Uncertainty in Market Clearing Price for electricity, Annual Operating Costs and Construction Costs primarily influence lifetime Net Present Values (NPV) and hence IRR % for Utilities. Generation Costs in addition are also influenced by Fuel Costs, Plant Output, Plant Availability and Plant Capacity Factor. Therefore for a site based on 3 single modules, located in North America, Generations Costs of 28.5 $/MWh are required to achieve an IRR of 20%, a level which enables IRIS to compete with all other forms of electricity production. Plant size is critical to commercial success. Sustained (lifetime) high factors for Plant Output, Availability and Capacity Factor are required to achieve a competitive advantage. Modularity offers Utilities the option to match their investments with market conditions, adding additional capacity as

  10. Off-Angle Iris Correction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Thompson, Joseph T [ORNL; Karakaya, Mahmut [ORNL; Boehnen, Chris Bensing [ORNL

    2016-01-01

    In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

  11. IRIS Toxicological Review of Thallium and Compounds ...

    Science.gov (United States)

    Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certain tumors. EPA's assessment of noncancer health effects and carcinogenic potential of thallium compounds was last prepared and added to the IRIS database between 1988 and 1990. The IRIS program is preparing an assessment that will incorporate current health effects information available for thallium and compounds, and current risk assessment methods. The IRIS assessment for thallium compounds will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physiochemical and toxicokinetic properties of a chemical, and its toxicity in humans and experimental systems. The assessment will present reference values for the noncancer effects of thallium compounds (RfD and Rfc), and a cancer assessment. The Toxicological Review and IRIS Summary have been subject to Agency review, Interagency review, and external scientific peer review. The final product will reflect the Agency opinion on the overall toxicity of thallium and compounds. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for thallium and compounds. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effec

  12. Role of Arbuscular Mycorrhizal Fungi on Iris

    Directory of Open Access Journals (Sweden)

    CHEN Yuan

    2014-06-01

    Full Text Available For efficiency using the amphibious plant iris to restore polluted water, the promoting effect of different arbuscular mycorrhiza fungi(AMFon iris was investigated, by monitoring the plant growth index, the physicochemical properties of the soil and the plant photosynthesis indexes. The result showed that the promoting effects of the AMF on the aboveground part and the underground part of the iris were based on different mechanism. For the underground part of the iris, the AMF stimulated its growth through the nutrient enrichment which was performed by the enormous hypha network. The nitrogen absorbing rate of the G. mosseae and the G. intraradices infected iris increased about 71.75% and 42.55%, and the phosphorous absorbing rate increased 8.36% and 9.5% separately. For the aboveground part of the iris, the AMF strengthened the conductance of the leaves’ stomas to control the balance between the net photosynthesis rate and the transpiration rate, so that the utilization rate of water resources was optimized, the metabolic rate was accelerated and the growth of the plant was promoted eventually. In this study, the promoting effect of the G. mosseae on the photosynthesis rate of the iris was significantly better than that of the G. intraradices(P<0.05.

  13. LOCA analysis of the IRIS reactor

    International Nuclear Information System (INIS)

    Bajs, T.; Grgic, D.; Cavlina, N.

    2003-01-01

    The IRIS reactor (International Reactor Innovative and Secure) is an integral, light water cooled, medium power reactor. IRIS has been selected as an International Near Term Deployable (INTD) reactor, within the Generation IV International Forum activities. The IRIS concept addresses the key-requirements defined by the US DOE for next generation reactors, i.e. enhanced reliability and safety, and improved economics. It features innovative, advanced engineering, but it is firmly based on the proven technology of pressurized water reactors (PWR). An innovative safety approach has been developed to mitigate the IRIS response to small-to-medium Loss of Coolant Accident (LOCA). This strategy is based on the interaction of IRIS compact containment with the reactor vessel to limit initial blowdown, and on depressurization through the use of a passive Emergency Heat Removal System (EHRS). A small Automatic Depressurization System (ADS) provides supplementary depressurization capability. A pressure suppression system is provided to limit the pressure peak following the initial blowdown to well below the containment design limit. The ultimate result is that during a small-to-medium LOCA, the core remains covered for an extended period of time, without credit for emergency water injection or external core makeup. The IRIS LOCA response is based on 'maintaining water inventory' rather than on the principle of safety injection. This novel safety approach poses significant issues for computational and analysis methods since the IRIS vessel and containment are strongly coupled, and the system response is based on the interaction between the two. The small break LOCA was calculated using RELAP5/mod3.3 and GOTHIC codes. Break of the largest line connected to the IRIS Reactor Pressure Vessel (RPV) was analyzed. The results of the calculations confirmed good performance of the IRIS system during LOCA. (author)

  14. SEGMENTATION AND QUALITY ANALYSIS OF LONG RANGE CAPTURED IRIS IMAGE

    Directory of Open Access Journals (Sweden)

    Anand Deshpande

    2016-05-01

    Full Text Available The iris segmentation plays a major role in an iris recognition system to increase the performance of the system. This paper proposes a novel method for segmentation of iris images to extract the iris part of long range captured eye image and an approach to select best iris frame from the iris polar image sequences by analyzing the quality of iris polar images. The quality of iris image is determined by the frequency components present in the iris polar images. The experiments are carried out on CASIA-long range captured iris image sequences. The proposed segmentation method is compared with Hough transform based segmentation and it has been determined that the proposed method gives higher accuracy for segmentation than Hough transform.

  15. IRIS Toxicological Review of Dichloromethane (Methylene ...

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Dichloromethane (Methylene Chloride): In support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. This document presents background information and justification for the Intergrated Risk Information System (IRIS) Summary of the hazard and dose-response assessment of dichloromethane. IRIS Summaries may include oral reference dose (RfD) and inhalation reference concentration (RfC) values for chronic and other exposure durations, and a carcinogencity assessment. Internet/NCEA web site

  16. A novel iris localization algorithm using correlation filtering

    Science.gov (United States)

    Pohit, Mausumi; Sharma, Jitu

    2015-06-01

    Fast and efficient segmentation of iris from the eye images is a primary requirement for robust database independent iris recognition. In this paper we have presented a new algorithm for computing the inner and outer boundaries of the iris and locating the pupil centre. Pupil-iris boundary computation is based on correlation filtering approach, whereas iris-sclera boundary is determined through one dimensional intensity mapping. The proposed approach is computationally less extensive when compared with the existing algorithms like Hough transform.

  17. Porcine cadaver iris model for iris heating during corneal surgery with a femtosecond laser

    Science.gov (United States)

    Sun, Hui; Fan, Zhongwei; Wang, Jiang; Yan, Ying; Juhasz, Tibor; Kurtz, Ron

    2015-03-01

    Multiple femtosecond lasers have now been cleared for use for ophthalmic surgery, including for creation of corneal flaps in LASIK surgery. Preliminary study indicated that during typical surgical use, laser energy may pass beyond the cornea with potential effects on the iris. As a model for laser exposure of the iris during femtosecond corneal surgery, we simulated the temperature rise in porcine cadaver iris during direct illumination by the femtosecond laser. Additionally, ex-vivo iris heating due to femtosecond laser irradiation was measured with an infrared thermal camera (Fluke corp. Everett, WA) as a validation of the simulation.

  18. Deep Learning-Based Iris Segmentation for Iris Recognition in Visible Light Environment

    Directory of Open Access Journals (Sweden)

    Muhammad Arsalan

    2017-11-01

    Full Text Available Existing iris recognition systems are heavily dependent on specific conditions, such as the distance of image acquisition and the stop-and-stare environment, which require significant user cooperation. In environments where user cooperation is not guaranteed, prevailing segmentation schemes of the iris region are confronted with many problems, such as heavy occlusion of eyelashes, invalid off-axis rotations, motion blurs, and non-regular reflections in the eye area. In addition, iris recognition based on visible light environment has been investigated to avoid the use of additional near-infrared (NIR light camera and NIR illuminator, which increased the difficulty of segmenting the iris region accurately owing to the environmental noise of visible light. To address these issues; this study proposes a two-stage iris segmentation scheme based on convolutional neural network (CNN; which is capable of accurate iris segmentation in severely noisy environments of iris recognition by visible light camera sensor. In the experiment; the noisy iris challenge evaluation part-II (NICE-II training database (selected from the UBIRIS.v2 database and mobile iris challenge evaluation (MICHE dataset were used. Experimental results showed that our method outperformed the existing segmentation methods.

  19. Genetic context determines susceptibility to intraocular pressure elevation in a mouse pigmentary glaucoma

    Directory of Open Access Journals (Sweden)

    Cosma Ioan M

    2006-07-01

    Full Text Available Abstract Background DBA/2J (D2 mice develop an age-related form of glaucoma. Their eyes progressively develop iris pigment dispersion and iris atrophy followed by increased intraocular pressure (IOP and glaucomatous optic nerve damage. Mutant alleles of the Gpnmb and Tyrp1 genes are necessary for the iris disease, but it is unknown whether alleles of other D2 gene(s are necessary for the distinct later stages of disease. We initiated a study of congenic strains to further define the genetic requirements and disease mechanisms of the D2 glaucoma. Results To further understand D2 glaucoma, we created congenic strains of mice on the C57BL/6J (B6 genetic background. B6 double-congenic mice carrying D2-derived Gpnmb and Tyrp1 mutations develop a D2-like iris disease. B6 single-congenics with only the Gpnmb and Tyrp1 mutations develop milder forms of iris disease. Genetic epistasis experiments introducing a B6 tyrosinase mutation into the congenic strains demonstrated that both the single and double-congenic iris diseases are rescued by interruption of melanin synthesis. Importantly, our experiments analyzing mice at ages up to 27 months indicate that the B6 double-congenic mice are much less prone to IOP elevation and glaucoma than are D2 mice. Conclusion As demonstrated here, the Gpnmb and Tyrp1 iris phenotypes are both individually dependent on tyrosinase function. These results support involvement of abnormal melanosomal events in the diseases caused by each gene. In the context of the inbred D2 mouse strain, the glaucoma phenotype is clearly influenced by more genes than just Gpnmb and Tyrp1. Despite the outward similarity of pigment-dispersing iris disease between D2 and the B6 double-congenic mice, the congenic mice are much less susceptible to developing high IOP and glaucoma. These new congenic strains provide a valuable new resource for further studying the genetic and mechanistic complexity of this form of glaucoma.

  20. IRIS Bimonthly Public Meeting (Oct 2014)

    Science.gov (United States)

    The meeting was held to obtain input from the scientific community and the public on studies and data that will be used in the assessments of Diisononyl Phthalate (DINP) and Hexavalent Chromium (Cr(VI)) that are under IRIS development.

  1. IRIS Bimonthly Public Meeting (Apr 2014)

    Science.gov (United States)

    EPA hosted a public meeting/webinar to provide an opportunity for the public to give input and participate in an open discussion regarding several IRIS chemical assessments for Diethyl Phthalate (DEP) and Hexabromocyclododecane (HBCD).

  2. An Application for Descriptive Nearness: Iris Recognition

    Directory of Open Access Journals (Sweden)

    Polat Kadirhan

    2017-12-01

    Full Text Available Near Set Theory has various applications in the literature. In this paper, using the concept descriptive nearness, we show how to perform iris recognition. This process has a few algorithms given via Mathematica Script Language.

  3. SURVEY OF BIOMETRIC SYSTEMS USING IRIS RECOGNITION

    OpenAIRE

    S.PON SANGEETHA; DR.M.KARNAN

    2014-01-01

    The security plays an important role in any type of organization in today’s life. Iris recognition is one of the leading automatic biometric systems in the area of security which is used to identify the individual person. Biometric systems include fingerprints, facial features, voice recognition, hand geometry, handwriting, the eye retina and the most secured one presented in this paper, the iris recognition. Biometric systems has become very famous in security systems because it is not possi...

  4. Transient analysis of the IRIS reactor

    International Nuclear Information System (INIS)

    Bajs, T.; Oriani, L.; Ricotti, M.E.; Barroso, A.C.

    2002-01-01

    An international consortium of industry, laboratory, university and utility establishments, led by Westinghouse, is developing a modular, integral, light water cooled, small to medium power reactor, the International Reactor Innovative and Secure (IRIS). IRIS features innovative, advanced engineering, but it is firmly based on the proven technology of pressurized water reactors (PWR). Given the large number of organizations involved in the IRIS design, the RELAP5/MOD 3.3 code has been selected as the main system code. A nodalization of the reference IRIS design has been developed with a basic set of protective functions and controls. Engineered Safety Features of the concept are being also implemented, and in particular the Emergency Heat Removal System that is used for safety grade decay heat removal and in the small break LOCA response of IRIS (Large break LOCAs are eliminated in IRIS by the adoption of the Integral layout) This paper discusses developed model and transient behavior of the system for representative transient sequences.(author)

  5. Improved iris localization by using wide and narrow field of view cameras for iris recognition

    Science.gov (United States)

    Kim, Yeong Gon; Shin, Kwang Yong; Park, Kang Ryoung

    2013-10-01

    Biometrics is a method of identifying individuals by their physiological or behavioral characteristics. Among other biometric identifiers, iris recognition has been widely used for various applications that require a high level of security. When a conventional iris recognition camera is used, the size and position of the iris region in a captured image vary according to the X, Y positions of a user's eye and the Z distance between a user and the camera. Therefore, the searching area of the iris detection algorithm is increased, which can inevitably decrease both the detection speed and accuracy. To solve these problems, we propose a new method of iris localization that uses wide field of view (WFOV) and narrow field of view (NFOV) cameras. Our study is new as compared to previous studies in the following four ways. First, the device used in our research acquires three images, one each of the face and both irises, using one WFOV and two NFOV cameras simultaneously. The relation between the WFOV and NFOV cameras is determined by simple geometric transformation without complex calibration. Second, the Z distance (between a user's eye and the iris camera) is estimated based on the iris size in the WFOV image and anthropometric data of the size of the human iris. Third, the accuracy of the geometric transformation between the WFOV and NFOV cameras is enhanced by using multiple matrices of the transformation according to the Z distance. Fourth, the searching region for iris localization in the NFOV image is significantly reduced based on the detected iris region in the WFOV image and the matrix of geometric transformation corresponding to the estimated Z distance. Experimental results showed that the performance of the proposed iris localization method is better than that of conventional methods in terms of accuracy and processing time.

  6. Thermal hydraulic tradeoffs in the design of IRIS primary circuit

    International Nuclear Information System (INIS)

    Oriani, L.; Lombardi, C.; Ricotti, M.E.; Paramonov, D.; Carelli, M.; Conway, L.

    2001-01-01

    IRIS (International Reactor Innovative and Secure) is currently being developed by an international consortium, led by Westinghouse and including universities. In order to achieve high level of safety, reduce complexity and capital cost, and enhance proliferation resistance, an integral primary circuit configuration has been selected. The integral configuration (the core, steam generators, coolant pumps, pressurizer and control rods are all contained within the reactor vessel) has no loop piping and thereby eliminates the possibility of large loss of coolant accidents. If the reactor vessel and components are designed for a very high level of natural circulation, which is promoted by an integral design, the consequence of loss of flow accidents can be significantly reduced or even completely eliminated. Core and integral primary circuit design optimization has been performed using the OSCAR computer code, a specialized tool for the analyses of the IRIS primary system developed at POLIMI. Results of trade-off studies of various in-vessel configurations explored to achieve tight packaging and high serviceability and/or replacement of components such as steam generators and pumps are reported. Effects of changes in secondary side parameters and steam generator design on system efficiency were explored together with the optimization of the vessel and steam generator dimensions and costs. The aim of the trade-off analyses was to limit the design space, and select a reference configuration for the IRIS reactor. (author)

  7. Management of sulcus-fixated single-piece intraocular lens-induced pigmentary glaucoma with 3-piece IOL exchange.

    Science.gov (United States)

    Rabie, Hossein Mohammad; Esfandiari, Hamed; Rikhtegar, Mohammad Hassan; Hekmat, Vahid

    2018-02-01

    To describe our experience with exchanging sulcus-fixated single-piece intraocular lens (IOL) with 3-piece IOLs for management of pigmentary glaucoma. In this retrospective study, records of patients who underwent sulcus-fixated single-piece IOL exchanged with 3-piece IOLs were retrieved, and demographic and baseline data of patients, type of IOL, pre- and post-IOL exchange BCVA, IOP, number of anti-glaucoma medications, and optic nerve head examination were documented. Baseline and final examinations were analyzed and compared. Mean age of the patients was 59 ± 10 years, and 5 (41.6%) were female. Mean interval between primary cataract extraction operation and IOL exchange was 17 ± 5 months. Nine patients received in sulcus implantation of Alcon SA60AT, and three patients had SN60WF model at the end of primary surgery. BCVA changed insignificantly from 0.06 ± 0.06 logMAR to 0.06 ± 0.06 after IOL exchange. (P = 0.22) IOP was controlled in 8 cases (66.6%), but four cases (33.3%) needed glaucoma surgery to further control glaucoma condition. IOP decreased significantly from preoperative 17 ± 3 to 14 ± 1 mmHg postoperatively. Patients with advanced age and higher baseline IOP were more likely to undergo glaucoma surgery after IOL exchange. (P = 0.07 and 0.00, respectively). single-piece IOL exchange with 3-piece IOL dramatically decreases pigment release and reduces IOP. Those with advanced age and higher IOP are less likely to respond to IOL exchange and may need glaucoma surgery to control high intraocular pressure.

  8. Molecular diagnostic in two families affected with Autosomic Recessive Pigmentary Retinitis

    International Nuclear Information System (INIS)

    Leal Esquivel, A.

    1996-01-01

    This study included two Costa Rican families with members affected by Recessive Pigmentary Autosomic Retinitis (RPAR). The first family (C1) from the province of San Jose, has 10 alive affected members, and 14 obligatory carriers. They present an Early Appearance Degeneration, RPAR tipe1 (cane-cone). The author used polymorphic markers (STRPs) to discard some related regions, with the RP in the literature. He also used the Linkage program, for the analysis of ligaments. The second family (P1), proceeding from Acosta (situated in the province of Alajuela), has 13 alive affected members and 23 obligatory carriers and they present numerous consanguineous unions. This case is a RPAR with Early Appearance (Night Blindness, fat ERG), but with a shower degeneration. The author concludes that, with studies such as this one, there will be a capacity to offer RP molecular diagnostic, and also advance in its knowledge and treatment. (S. Grainger)

  9. [Retinal pigmentary degeneration--clinical features, diagnostics and possibilities of treatment].

    Science.gov (United States)

    Grześk, Magdalena; Malukiewicz-Wiśniewska, Grazyna

    2007-01-01

    The purpose of this study was to evaluate clinical course of retinitis pigmentosa taking into consideration models of inheritance and possible treatment. Retinitis pigmentosa belongs to heterogeneous group of hereditary disorders, which are connected with gradual loss of the photoreceptor function, firstly rod cells subsequently cones, which is accompanied by the retinal pigmentary epithelium disorder. Retinitis pigmentosa connected with X chromosome is one of the most severe form of this disease that in polish population takes place with frequency at average 10-15% which is similar to ADRP--10-20%. Course of RP, despite many similarities may differ from each other and prognosis depends on model of inheritance. Unfortunately, in spite of many efforts, nowadays medicine do not have successful treatment for patients with RP.

  10. Molecular Genetics of Pigment Dispersion Syndrome and Pigmentary Glaucoma: New Insights into Mechanisms

    Directory of Open Access Journals (Sweden)

    Adrian A. Lahola-Chomiak

    2018-01-01

    Full Text Available We explore the ideas and advances surrounding the genetic basis of pigment dispersion syndrome (PDS and pigmentary glaucoma (PG. As PG is the leading cause of nontraumatic blindness in young adults and current tailored interventions have proven ineffective, a better understanding of the underlying causes of PDS, PG, and their relationship is essential. Despite PDS being a subclinical disease, a large proportion of patients progress to PG with associated vision loss. Decades of research have supported a genetic component both for PDS and conversion to PG. We review the body of evidence supporting a genetic basis in humans and animal models and reevaluate classical mechanisms of PDS/PG considering this new evidence.

  11. [Selective retina therapy in central serous chorioretinopathy with detachment of the pigmentary epithelium].

    Science.gov (United States)

    Klatt, C; Elsner, H; Pörksen, E; Brinkmann, R; Bunse, A; Birngruber, R; Roider, J

    2006-10-01

    Selective Retina Therapy (SRT) is a new and innovative laser treatment modality that selectively treats the retinal pigmentary epithelium while sparing the photoreceptors. This therapeutic concept appears to be particularly suitable for treating patients with acute or chronic central serous chorioretinopathy (CSC). We present preliminary results obtained in five patients who had CSC associated with pigmentary epithelium detachment (PED) and serous subretinal fluid (SRF) and who were treated with SRT. This case series was made up of five male patients (mean age 47 years) with chronic CSC and SRF resulting from PED. Examinations performed before and at 1 month and 3 months after the treatment were: BCVA, FLA, OCT (Zeiss OCT III). For SRT, confluent treatment of the PED (area of leakage) was carried out using a pulsed frequency-doubled, Q-switched Nd-YLF prototype laser (lambda=527 nm, t= 1.7 s, 100 Hz, energy = 150-250 J). Best corrected visual acuity at baseline was 0.53, while after 4 weeks it was 0.56 and after 12 weeks, 0.5. At baseline leakage was seen at the PED on fluorescein angiography in all patients. After 4 weeks leakage activity was no longer noted on angiography in 4 of 5 patients. OCT at baseline showed SRF at the edge of the PED in all patients, but in 4 of the 5 patients this was no longer detectable after 4 weeks. SRT is a safe and effective treatment for patients with CSC in which PED has caused SRF. Not a single case of rip syndrome was observed in this study, even though the PED was treated confluently. Since SRT spares the photoreceptors it is particularly suitable for the treatment of CSC, especially when the origin of leakage is located close to the fovea. The results indicate that SRT leads to reconstruction of the outer blood-retina barrier.

  12. 75 FR 25239 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2010-05-07

    ... Information System (IRIS); Announcement of Availability of Literature Searches for IRIS Assessments AGENCY: Environmental Protection Agency. ACTION: Notice; Announcement of availability of literature searches for IRIS... the availability of literature searches for four IRIS assessments and requesting scientific...

  13. Assessment of Urbanization on the Integrated Land-Ocean-Atmosphere Environment in Coastal Metropolis in Preparation for HyspIRI

    Science.gov (United States)

    Sequera, Pedro; McDonald, Kyle C.; Gonzalez, Jorge; Arend, Mark; Krakauer, Nir; Bornstein, Robert; Luvll, Jeffrey

    2012-01-01

    The need for comprehensive studies of the relationships between past and projected changes of regional climate and human activity in comple x urban environments has been well established. The HyspIRI preparato ry airborne activities in California, associated science and applicat ions research, and eventually HyspIRI itself provide an unprecedented opportunity for development and implementation of an integrated data and modeling analysis system focused on coastal urban environments. We will utilize HyspIRI preparatory data collections in developing ne w remote sensing-based tools for investigating the integrated urban e nvironment, emphasizing weather, climate, and energy demands in compl ex coastal cities.

  14. International Reactor Innovative and Secure (IRIS) summary

    International Nuclear Information System (INIS)

    Carelli, Mario D.

    2001-01-01

    The IRIS (International Reactor Innovative and Secure) reactor is described in the first part of the presentation. IRIS is a light water cooled reactor with an integral configuration, where steam generators, pumps and pressurizer are inside the reactor vessel. Partially funded by the DOE NERI program, IRIS is being developed by an international consortium of 16 organizations from seven countries. A key IRIS characteristic is its 'safety by design' approach which strives to eliminate, by design, as many accidents as possible rather than coping with their consequences. Initial returns are very positive; out of the eight Class IV accidents considered in the AP600 only one remains as a Class IV in IRIS, and at much reduced probability. Small-to-medium LOCAs have minimal consequences as the core remains safely under water for days, without the need for safety injection or water makeup. In spite of its novelty IRIS is firmly grounded on proven LWR technology and therefore a prototype is not needed to assure design certification. Rather, very extensive scaled tests will be performed to investigate the performance of in-vessel components such as steam generators and pumps, both individually and as interactive systems. Accident sequences will also be simulated and tested to prove IRIS safety by design claims. The first core fuel is less than 5% enriched and the fuel assembly is very similar to existing PWR assemblies, so there is no licensing challenge regarding the fuel. Because of the safety by design approach, yielding simplifications In design and accident management (e.g., IRIS does not have an emergency core cooling system), some accident scenarios are eliminated and others have lesser consequences. Thus, simplification and streamlining of the regulatory process might be possible. Risk informed regulation will be coupled with safety by design to show lower accident and damage probabilities. This could lead to a relaxation of siting regulatory requirements. It is

  15. Proton beam radiotherapy of iris melanoma

    International Nuclear Information System (INIS)

    Damato, Bertil; Kacperek, Andrzej; Chopra, Mona; Sheen, Martin A.; Campbell, Ian R.; Errington, R. Douglas

    2005-01-01

    Purpose: To report on outcomes after proton beam radiotherapy of iris melanoma. Methods and Materials: Between 1993 and 2004, 88 patients with iris melanoma received proton beam radiotherapy, with 53.1 Gy in 4 fractions. Results: The patients had a mean age of 52 years and a median follow-up of 2.7 years. The tumors had a median diameter of 4.3 mm, involving more than 2 clock hours of iris in 32% of patients and more than 2 hours of angle in 27%. The ciliary body was involved in 20%. Cataract was present in 13 patients before treatment and subsequently developed in another 18. Cataract had a 4-year rate of 63% and by Cox analysis was related to age (p = 0.05), initial visual loss (p < 0.0001), iris involvement (p < 0.0001), and tumor thickness (p < 0.0001). Glaucoma was present before treatment in 13 patients and developed after treatment in another 3. Three eyes were enucleated, all because of recurrence, which had an actuarial 4-year rate of 3.3% (95% CI 0-8.0%). Conclusions: Proton beam radiotherapy of iris melanoma is well tolerated, the main problems being radiation-cataract, which was treatable, and preexisting glaucoma, which in several patients was difficult to control

  16. Safety design features of the IRIS

    International Nuclear Information System (INIS)

    2009-01-01

    The International Reactor Innovative and Secure (IRIS) is an advanced, integral, light water cooled reactor of medium generating capacity (335 MW(e)), that features an integral reactor vessel containing all the reactor primary system components, including steam generators, coolant pumps, pressurizer and heaters, and control rod drive mechanisms; in addition to the typical core, internals, control rods and neutron reflector. This integral configuration allows for the use of a small, high design pressure, spherical steel containment which results in a significant reduction in the size of the nuclear island. Other IRIS innovations include a simplified passive safety system concept and equipment features that derive from the 'safety-by-design' philosophy. This design approach allows for elimination of certain accident initiators at the design stage, or when outright elimination is not possible, decreases accident consequences and/or their probability of occurrence. Major design characteristics of the IRIS are given. As part of the IRIS pre-application licensing review by the U.S. Nuclear Regulatory Commission (NRC), the IRIS design team has developed a test plan that will provide the necessary data for safety analysis computer model verification, as well as for verifying the manufacturing feasibility, operability, and durability of new component designs

  17. Balloon cell nevus of the iris.

    Science.gov (United States)

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  18. [Coding Causes of Death with IRIS Software. Impact in Navarre Mortality Statistic].

    Science.gov (United States)

    Floristán Floristán, Yugo; Delfrade Osinaga, Josu; Carrillo Prieto, Jesus; Aguirre Perez, Jesus; Moreno-Iribas, Conchi

    2016-08-02

    There are few studies that analyze changes in mortality statistics derived from the use of IRIS software, an automatic system for coding multiple causes of death and for the selection of the underlying cause of death, compared to manual coding. This study evaluated the impact of the use of IRIS in the Navarre mortality statistic. We proceeded to double coding 5,060 death certificates corresponding to residents in Navarra in 2014. We calculated coincidence between the two encodings for ICD10 chapters and for the list of causes of the Spanish National Statistics Institute (INE-102) and we estimated the change on mortality rates. IRIS automatically coded 90% of death certificates. The coincidence to 4 characters and in the same chapter of the CIE10 was 79.1% and 92.0%, respectively. Furthermore, coincidence with the short INE-102 list was 88.3%. Higher matches were found in death certificate of people under 65 years. In comparison with manual coding there was an increase in deaths from endocrine diseases (31%), mental disorders (19%) and disease of nervous system (9%), while a decrease of genitourinary system diseases was observed (21%). The coincidence at level of ICD10 chapters coding by IRIS in comparison to manual coding was 9 out of 10 deaths, similar to what is observed in other studies. The implementation of IRIS has led to increased of endocrine diseases, especially diabetes and hyperlipidaemia, and mental disorders, especially dementias.

  19. AHMCT Intelligent Roadway Information System (IRIS) technical support and testing

    Science.gov (United States)

    2011-12-31

    This report documents the research project AHMCT IRIS Technical Support and Testing, : performed under contract 65A0275, Task ID 1777. It presents an overview of the Intelligent : Roadway Information System (IRIS), and its design and function. ...

  20. Comparison of features response in texture-based iris segmentation

    CSIR Research Space (South Africa)

    Bachoo, A

    2009-03-01

    Full Text Available the Fisher linear discriminant and the iris region of interest is extracted. Four texture description methods are compared for segmenting iris texture using a region based pattern classification approach: Grey Level Co-occurrence Matrix (GLCM), Discrete...

  1. IRIS Toxicological Review of Tetrahydrofuran (THF) (Interagency Science Discussion Draft)

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review of Tetrahydrofuran, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the iris/process.htm">IRIS Assessment Development Proc...

  2. IRIS Assessment Plan for Uranium (Scoping and Problem Formulation Materials)

    Science.gov (United States)

    In January 2018, EPA released the IRIS Assessment Plan for Uranium (Oral Reference Dose) (Scoping and Problem Formulation Materials). An IRIS Assessment Plan (IAP) communicates to the public the plan for assessing each individual chemical and includes summary informatio...

  3. IRIS Toxicological Review of Vinyl Chloride (Final Report, 2000)

    Science.gov (United States)

    EPA is announcing the release of the final report, Toxicological Review of Vinyl Chloride: in support of the Integrated Risk Information System (IRIS). The updated Summary for Vinyl Chloride and accompanying Quickview have also been added to the IRIS Database.

  4. A fourier transform quality measure for iris images

    CSIR Research Space (South Africa)

    Makinana, S

    2014-08-01

    Full Text Available to ensure that good quality images are selected for feature extraction, in order to improve iris recognition system. In addition, this research proposes a measure of iris image quality using a Fourier Transform. The experimental results demonstrate...

  5. Correlation of iris biometrics and DNA

    DEFF Research Database (Denmark)

    Harder, Stine; Clemmensen, Line Katrine Harder; Dahl, Anders Bjorholm

    2013-01-01

    The presented work concerns prediction of complex human phenotypes from genotypes. We were interested in correlating iris color and texture with DNA. Our data consist of 212 eye images along with DNA: 32 single-nucleotide polymorphisms (SNPs). We used two types of biometrics to describe the eye...... images: One for iris color and one for iris texture. Both biometrics were high dimensional and a sparse principle component analysis (SPCA) reduced the dimensions and resulted in a representation of data with good interpretability. The correlations between the sparse principal components (SPCs......) and the 32 SNPs were found using a canonical correlation analysis (CCA). The result was a single significant canonical correlation (CC) for both biometrics. Each CC comprised two correlated canonical variables, consisting of a linear combination of SPCs and a linear combination of SNPs, respectively...

  6. Bilateral acute iris transillumination: Case report

    Directory of Open Access Journals (Sweden)

    Cumali Degirmenci

    2016-04-01

    Full Text Available Bilateral acute iris transillumination (BAIT is a recently defined disease characterized with bilateral acute, severe pigment dispersion of iris and pupil sphincter paralysis. The etiopathogenesis of the disease is unknown, but antibiotics such as moxifloxacin, clarithromycin, viral infections, and fumigation therapies were considered as probable etiologic factors. A 33-year-old female was referred to our clinic for acute iridocyclitis refractory to azathioprine, colchicum and corticosteroid treatments. Ophthalmic examination revealed bilateral pigment dispersion, significant iris transillumination, heavy pigment deposition in iridocorneal angle, and elevated intraocular pressure. Upon systemic evaluation she was found to have bacterial urinary tract infection. BAIT is an important cause of pigment dispersion and clinicians must be vigilant for this condition to avoid unnecessary diagnostic tests and treatment.

  7. Internet Renewable energy Information System (IRIS)

    DEFF Research Database (Denmark)

    Bäurle, Britta; Nielsen, Vilhjalmur; Ménard, Lionel

    1999-01-01

    Even though the Internet is now a widely accessible data source, the unorganised flood of information makes a specific request e.g. for renewable energy products inefficient. In addition, existing databases on renewable energies are often old and incomplete. The objective of IRIS has been...... to organise and retrieve renewable energy product information on the Internet instead of collecting it manually. Updating coincides with the self interestself-interest of manufacturers to present their latest renewable energy products on their own HTML documents. IRIS is based on a set of powerful tools...... and intends to find, extract, collect and index HTML documents with standardised META tags that are widely spread across web servers on the Internet. This paper presents the structure of IRIS, the software tools, and gives one example of how to categorise and prepare web-sites with product information...

  8. Image compression with Iris-C

    Science.gov (United States)

    Gains, David

    2009-05-01

    Iris-C is an image codec designed for streaming video applications that demand low bit rate, low latency, lossless image compression. To achieve compression and low latency the codec features the discrete wavelet transform, Exp-Golomb coding, and online processes that construct dynamic models of the input video. Like H.264 and Dirac, the Iris-C codec accepts input video from both the YUV and YCOCG colour spaces, but the system can also operate on Bayer RAW data read directly from an image sensor. Testing shows that the Iris-C codec is competitive with the Dirac low delay syntax codec which is typically regarded as the state-of-the-art low latency, lossless video compressor.

  9. 48XXYY Syndrome in an Adult with Type 2 Diabetes Mellitus, Unilateral Renal Aplasia, and Pigmentary Retinitis.

    Science.gov (United States)

    Zantour, Baha; Sfar, Mohamed Habib; Younes, Samia; Alaya, Wafa; Kamoun, Mahdi; Mkaouar, Emna; Jerbi, Saida

    2010-01-01

    A 45-year-old male was referred for diabetes mellitus. Clinical examination found a family history of multiple precocious deaths, strong consanguinity, personal history of seizures during childhood, small testicles, small penis, sparse body hair, long arms and legs, dysmorphic features, mental retardation, dysarthria, tremor, and mild gait ataxia. Investigations found pigmentary retinitis, metabolic syndrome, unilateral renal aplasia, and hypergonadotropic hypogonadism, and ruled out mitochondrial cytopathy and leucodystrophy. Karyotype study showed a 48XXYY chromosomal type. Renal aplasia and pigmentary retinitis have not been described in 48XXYY patients. They may be related to the chromosomal sex aneuploidy, or caused by other genetic aberrations in light of the high consanguinity rate in the patient's family.

  10. 48XXYY Syndrome in an Adult with Type 2 Diabetes Mellitus, Unilateral Renal Aplasia, and Pigmentary Retinitis

    Directory of Open Access Journals (Sweden)

    Baha Zantour

    2010-01-01

    Full Text Available A 45-year-old male was referred for diabetes mellitus. Clinical examination found a family history of multiple precocious deaths, strong consanguinity, personal history of seizures during childhood, small testicles, small penis, sparse body hair, long arms and legs, dysmorphic features, mental retardation, dysarthria, tremor, and mild gait ataxia. Investigations found pigmentary retinitis, metabolic syndrome, unilateral renal aplasia, and hypergonadotropic hypogonadism, and ruled out mitochondrial cytopathy and leucodystrophy. Karyotype study showed a 48XXYY chromosomal type. Renal aplasia and pigmentary retinitis have not been described in 48XXYY patients. They may be related to the chromosomal sex aneuploidy, or caused by other genetic aberrations in light of the high consanguinity rate in the patient's family.

  11. An Overlap Syndrome of Pigment Dispersion and Pigmentary Glaucoma accompanied by Marfan Syndrome: Case Report with Literature Review.

    Science.gov (United States)

    Chakravarti, Tutul; Spaeth, George

    2013-01-01

    'Overlap syndrome' describes the situation in which two or more 'independent' conditions are present, either one of which could cause a particular finding. This current presentation reports a case with bilateral pigment dispersion syndrome (PDS), advanced pigmentary glaucoma (PG), and the Marfan syndrome, with bilateral subluxation of the lenses, and large short-term and long-term fluctuations of intraocular pressure. It is interesting to consider whether the associated advanced glaucomatous nerve damage could be a manifestation of just the PDS, just the Marfan syndrome, or rather a combination of these two overlapping independent conditions. How to cite this article: Chakravarti T, George S. An Overlap Syndrome of Pigment Dispersion and Pigmentary Glaucoma accompanied by Marfan Syndrome: Case Report with Literature Review. J Current Glau Prac 2013;7(2):91-95.

  12. Cataract influence on iris recognition performance

    Science.gov (United States)

    Trokielewicz, Mateusz; Czajka, Adam; Maciejewicz, Piotr

    2014-11-01

    This paper presents the experimental study revealing weaker performance of the automatic iris recognition methods for cataract-affected eyes when compared to healthy eyes. There is little research on the topic, mostly incorporating scarce databases that are often deficient in images representing more than one illness. We built our own database, acquiring 1288 eye images of 37 patients of the Medical University of Warsaw. Those images represent several common ocular diseases, such as cataract, along with less ordinary conditions, such as iris pattern alterations derived from illness or eye trauma. Images were captured in near-infrared light (used in biometrics) and for selected cases also in visible light (used in ophthalmological diagnosis). Since cataract is a disorder that is most populated by samples in the database, in this paper we focus solely on this illness. To assess the extent of the performance deterioration we use three iris recognition methodologies (commercial and academic solutions) to calculate genuine match scores for healthy eyes and those influenced by cataract. Results show a significant degradation in iris recognition reliability manifesting by worsening the genuine scores in all three matchers used in this study (12% of genuine score increase for an academic matcher, up to 175% of genuine score increase obtained for an example commercial matcher). This increase in genuine scores affected the final false non-match rate in two matchers. To our best knowledge this is the only study of such kind that employs more than one iris matcher, and analyzes the iris image segmentation as a potential source of decreased reliability

  13. 48XXYY Syndrome in an Adult with Type 2 Diabetes Mellitus, Unilateral Renal Aplasia, and Pigmentary Retinitis

    OpenAIRE

    Zantour, Baha; Sfar, Mohamed Habib; Younes, Samia; Alaya, Wafa; Kamoun, Mahdi; Mkaouar, Emna; Jerbi, Saida

    2010-01-01

    A 45-year-old male was referred for diabetes mellitus. Clinical examination found a family history of multiple precocious deaths, strong consanguinity, personal history of seizures during childhood, small testicles, small penis, sparse body hair, long arms and legs, dysmorphic features, mental retardation, dysarthria, tremor, and mild gait ataxia. Investigations found pigmentary retinitis, metabolic syndrome, unilateral renal aplasia, and hypergonadotropic hypogonadism, and ruled out mitochon...

  14. Pigmentary Markers in Danes--Associations with Quantitative Skin Colour, Nevi Count, Familial Atypical Multiple-Mole, and Melanoma Syndrome.

    Directory of Open Access Journals (Sweden)

    Peter Johansen

    Full Text Available To investigate whether pigmentation genes involved in the melanogenic pathway (melanogenesis contributed to melanoma predisposition, we compared pigmentary genetics with quantitative skin pigmentation measurements, the number of atypical nevi, the total nevus count, and the familial atypical multiple mole and melanoma (FAMMM syndrome. We typed 32 pigmentary SNP markers and sequenced MC1R in 246 healthy individuals and 116 individuals attending periodic control for malignant melanoma development, 50 of which were diagnosed with FAMMM. It was observed that individuals with any two grouped MC1R variants (missense, NM_002386:c. 456C > A (p.TYR152*, or NM_002386:c.83_84insA (p.Asn29Glnfs*14 had significantly (p<0.001 lighter skin pigmentation of the upper-inner arm than those with none or one MC1R variant. We did not observe any significant association of the MC1R variants with constitutive pigmentation measured on the buttock area. We hypothesize that the effect of MC1R variants on arm pigmentation is primarily reflecting the inability to tan when subjected to UVR. A gender specific effect on skin pigmentation was also observed, and it was found that the skin pigmentation of females on average were darker than that of males (p<0.01. We conclude that MC1R variants are associated with quantitative skin colour in a lightly pigmented Danish population. We did not observe any association between any pigmentary marker and the FAMMM syndrome. We suggest that the genetics of FAMMM is not related to the genetics of the pigmentary pathway.

  15. A modified COMS plaque for iris melanoma

    Directory of Open Access Journals (Sweden)

    Daniel J. Scanderbeg

    2011-09-01

    Full Text Available Melanoma of the iris is a rare condition compared to posterior ocular tumors and in this case report we presenta 51-year-old female patient with diffuse iris melanoma. Traditional COMS (Collaborative Ocular Melanoma Studyplaques are used at our institution for radiation therapy, so a novel modification of the traditional plaque was requiredto allow better conformance with placement on the cornea. The usual silastic insert was machined to dimensions incompliance with the cornea, placed without incident, and treatment delivered with excellent patient tolerance of themodified plaque.

  16. IRIS Toxicological Review of Trichloroethylene (TCE) ...

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroethylene (TCE) that when finalized will appear on the Integrated Risk Information System (IRIS) database. The purpose of this Toxicological Review is to provide scientific support and rationale for the hazard and dose-response assessment in IRIS pertaining to chronic exposure to trichloroethylene. It is not intended to be a comprehensive treatise on the chemical or toxicological nature of trichloroethylene.

  17. Plateau iris secondary to iridociliary cysts.

    Science.gov (United States)

    Vila-Arteaga, J; Díaz-Céspedes, R A; Suriano, M M

    2015-11-01

    We present a case of plateau iris and glaucoma due to multiple unilateral iridociliary cysts. The patient was treated with iridotomy Nd: YAG laser and 360° iridoplasty, without achieving pressure control. Phacoemulsification improved the hypertension. Dynamic gonioscopy and OCT of the anterior chamber was also performed before and after treatment. Iridociliary cysts are a benign condition that can cause iris plateau configuration, and can produce a difficult to treat ocular hypertension. Cystotomy, peripheral iridoplasty, and other treatments have been proposed. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  18. IRIS Toxicological Review of Inorganic Arsenic (Cancer) ...

    Science.gov (United States)

    EPA's Science Advisory Board (SAB) conducted a review of the scientific basis supporting the human health cancer hazard and dose-response assessment of inorganic arsenic that will appear on the Integrated Risk Information System (IRIS) database. EPA revised the assessment and is now returning the assessment to the SAB and releasing the document to the public for a focused review of EPA's responses to the SAB recommendations. This draft IRIS health assessment addresses only cancer human health effects that may result from chronic exposure to this chemical.

  19. A patient with multiple iris | Asselman | Southern African Journal of ...

    African Journals Online (AJOL)

    IRIS results from a pathological inflammatory response to pre-existing infective, host or other antigens, alive or dead, causing clinical deterioration in HIV-infected patients after initiating ART.1 A case definition for IRIS is shown in Table I. The most common forms of IRIS described occur in association with mycobacterial and ...

  20. IRIS: A global approach to nuclear power renaissance

    International Nuclear Information System (INIS)

    Carelli, M.D.

    2004-01-01

    Improved international reactor IRIS (International Reactor Innovative and Secure) is discussed. IRIS is defined as a modular reactor with integral arrangement and water coolant. Industrial companies, research, scientific groups and electric power producers of different countries (USA, Great Britain, Italy, Spain, Brazil, Russia, Mexico, Japan, Croatia) take part in the realization of IRIS. Basic parameters of the reactor, construction characteristics, arrangement are presented [ru

  1. IRIS: Supporting & Managing the Research Life-Cycle

    Science.gov (United States)

    Bollini, Andrea; Mennielli, Michele; Mornati, Susanna; Palmer, David T.

    2016-01-01

    IRIS is a new Current Research Information System (CRIS) developed by Cineca to upgrade and replace two previous solutions that have been used by Italian universities in the last 10 years. At the end of 2015, sixty-three Italian institutions are using IRIS. One of the main components of IRIS is DSpace-CRIS, an open source solution that can also be…

  2. Ethnicity distinctiveness through iris texture features using Gabor filters

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, Gugulethu P

    2017-02-01

    Full Text Available Research in iris biometrics has been focused on utilizing iris features as a means of identity verification and authentication. However, not enough research work has been done to explore iris textures to determine soft biometrics such as gender...

  3. Pigmentary changes and atopic dermatitis in a patient with Seckel syndrome.

    Science.gov (United States)

    Brackeen, Amy; Babb-Tarbox, Michelle; Smith, Jennifer

    2007-01-01

    Seckel syndrome is a very rare form of primordial dwarfism characterized by antenatal and postnatal growth delay, proportionate extreme short stature, a prominent beak-like nose, hypoplasia of the malar area, small chin, microcephaly, deformed ears lacking lobules, skeletal malformations, mental retardation, and developmental delay. This syndrome has been described with associated disorders of orthopedic, neurologic, hematologic, cardiac, and ocular systems; however, only a few reports mention dermatologic involvement. We describe a 5-year-old girl with classic Seckel syndrome who presented with moderately severe atopic dermatitis and diffuse hypopigmented macules and papules.

  4. Distribution and multiplication of iris severe mosaic potyvirus in bulbous Iris in relation to metabolic activity : implications for ISMV detection

    NARCIS (Netherlands)

    Vlugt, van der C.I.M.

    1994-01-01

    During cultivation of iris, several viruses may cause severe damage like yield reduction and discoloration of the plant. In commercial stocks in the Netherlands virtually all plants are infected with iris mild mosaic virus (IMMV) while iris severe mosaic virus (ISMV) and narcissus latent

  5. On techniques for angle compensation in nonideal iris recognition.

    Science.gov (United States)

    Schuckers, Stephanie A C; Schmid, Natalia A; Abhyankar, Aditya; Dorairaj, Vivekanand; Boyce, Christopher K; Hornak, Lawrence A

    2007-10-01

    The popularity of the iris biometric has grown considerably over the past two to three years. Most research has been focused on the development of new iris processing and recognition algorithms for frontal view iris images. However, a few challenging directions in iris research have been identified, including processing of a nonideal iris and iris at a distance. In this paper, we describe two nonideal iris recognition systems and analyze their performance. The word "nonideal" is used in the sense of compensating for off-angle occluded iris images. The system is designed to process nonideal iris images in two steps: 1) compensation for off-angle gaze direction and 2) processing and encoding of the rotated iris image. Two approaches are presented to account for angular variations in the iris images. In the first approach, we use Daugman's integrodifferential operator as an objective function to estimate the gaze direction. After the angle is estimated, the off-angle iris image undergoes geometric transformations involving the estimated angle and is further processed as if it were a frontal view image. The encoding technique developed for a frontal image is based on the application of the global independent component analysis. The second approach uses an angular deformation calibration model. The angular deformations are modeled, and calibration parameters are calculated. The proposed method consists of a closed-form solution, followed by an iterative optimization procedure. The images are projected on the plane closest to the base calibrated plane. Biorthogonal wavelets are used for encoding to perform iris recognition. We use a special dataset of the off-angle iris images to quantify the performance of the designed systems. A series of receiver operating characteristics demonstrate various effects on the performance of the nonideal-iris-based recognition system.

  6. Iris unwrapping using the Bresenham circle algorithm for real-time iris recognition

    Science.gov (United States)

    Carothers, Matthew T.; Ngo, Hau T.; Rakvic, Ryan N.; Broussard, Randy P.

    2015-02-01

    An efficient parallel architecture design for the iris unwrapping process in a real-time iris recognition system using the Bresenham Circle Algorithm is presented in this paper. Based on the characteristics of the model parameters this algorithm was chosen over the widely used polar conversion technique as the iris unwrapping model. The architecture design is parallelized to increase the throughput of the system and is suitable for processing an inputted image size of 320 × 240 pixels in real-time using Field Programmable Gate Array (FPGA) technology. Quartus software is used to implement, verify, and analyze the design's performance using the VHSIC Hardware Description Language. The system's predicted processing time is faster than the modern iris unwrapping technique used today∗.

  7. Surgical treatment of iris and ciliary body melanoma: follow-up of a 25-year series of patients

    DEFF Research Database (Denmark)

    Klauber, Stefan; Jensen, Peter K; Prause, Jan U

    2010-01-01

    Purpose: To evaluate outcome of surgical resection of iris and irido-ciliary melanomas. Method: Retrospective analysis of all cases treated in Denmark 1975-1999 with clinical follow-up in 2002 and death certificate analysis in 2008. A quality of life questionnaire was completed at follow-up. Resu......Purpose: To evaluate outcome of surgical resection of iris and irido-ciliary melanomas. Method: Retrospective analysis of all cases treated in Denmark 1975-1999 with clinical follow-up in 2002 and death certificate analysis in 2008. A quality of life questionnaire was completed at follow...... time. However, none had changed job as a consequence of the surgical treatment. Only two patients were emotionally affected by the diagnosis of iris melanoma. Conclusion: Resection of small iris and irido-ciliary melanomas is a safe and efficient procedure, provided that strict diagnostic and surgical...

  8. Iris recognition based on key image feature extraction.

    Science.gov (United States)

    Ren, X; Tian, Q; Zhang, J; Wu, S; Zeng, Y

    2008-01-01

    In iris recognition, feature extraction can be influenced by factors such as illumination and contrast, and thus the features extracted may be unreliable, which can cause a high rate of false results in iris pattern recognition. In order to obtain stable features, an algorithm was proposed in this paper to extract key features of a pattern from multiple images. The proposed algorithm built an iris feature template by extracting key features and performed iris identity enrolment. Simulation results showed that the selected key features have high recognition accuracy on the CASIA Iris Set, where both contrast and illumination variance exist.

  9. IRIS Bimonthly Public Meeting (Jun 2014)

    Science.gov (United States)

    On June 25-27, 2014, EPA hosted a public meeting/webinar, to provide an opportunity for the public to give input and participate in an open discussion regarding several IRIS chemical assessments of Hexavalent Chromium (Cr(VI)) and Inorganic Arsenic (iAs).

  10. IRIS Public Science Meeting (June 2016)

    Science.gov (United States)

    This June 2016 public meeting is made available to solicit comments on the public comment draft of the IRIS Assessment of tert-Butanol. The draft document was re-opened in the docket for a 60-day public comment period closing on July 16, 2016.

  11. Iris Murdoch, Liberal Education and Human Flourishing

    Science.gov (United States)

    Evans, William

    2009-01-01

    Articulating the good of liberal education--what we should teach and why we should teach it--is necessary to resist the subversion of liberal education to economic or political ends and the mania for measurable skills. I argue that Iris Murdoch's philosophical writings enrich the work of contemporary Aristotelians, such as Joseph Dunne and…

  12. Iris recognition using the JAVAVis Library

    Directory of Open Access Journals (Sweden)

    L.Martin García

    2008-12-01

    Full Text Available This project has been created to develop a biometric identification system through a man’s iris using a computer to perform the processing of the pictures. To develop this application, and to differentiate the project from others who have already implemented, we have used the image processing library JAVAVis and JAVA as a programming language.

  13. IRI profile parameters at equatorial latitudes

    International Nuclear Information System (INIS)

    Reinisch, B.W.; Huang Xueqin; Conway, J.

    2002-01-01

    The IRI bottom-side electron density profile is specified as a function of three parameters B0, B1, and D1 describing the F2 layer thickness and shape, and the shape of the F1 layer, respectively. Together with the URSI or CCIR coefficients for the F2 layer peak density and height, they completely specify the profiles as function of time, season and solar activity. In support of the international effort of determining the best set of parameters we have analyzed the diurnal variations of B0, B1, and D1 for Jicamarca for high solar activity during 1999 and 2000 for different seasons and magnetic activity. The B0 values vary from a minimum of ∼95 km at 0300 LT to ∼250 km at local noon (1700 UT). The diurnal variation is similar to the IRI2000 prediction. B1 varies from ∼1.9 at daytime to ∼2.2 at night. The value of D1 is ∼0.5. The parameters show little Kp dependence. Standard deviations are shown. We calculated the ionospheric total electron contents for March and April 1998 from the ionogram profiles at Jicamarca and compared them with IRI predictions using the IRI 2000 parameters. While there is fair agreement, a significant time shift of 1 to 2 hours occurs in the transition from night to daytime values. (author)

  14. Characterization of Structural and Pigmentary Colors in Common Emigrant (Catopsilia Pomona) Butterfly

    International Nuclear Information System (INIS)

    Ghate, Ekata; Kulkarni, G. R.; Bhoraskar, S. V.; Adhi, K. P.

    2011-01-01

    Study of structural colors in case of insects and butterflies is important for their biomimic and biophotonics applications. Structural color is the color which is produced by physical structures and their interaction with light while pigmentary color is produced by absorption of light by pigments. Common Emigrant butterfly is widely distributed in India. It is of moderate size with wing span of about 60-80 mm. The wings are broadly white with yellow or sulphur yellow coloration at places as well as few dark black patches. It belongs to family Pieridae. A study of structural color in case of Common Emigrant butterfly has been carried out in the present work. The characterization of wing color was performed using absorption spectroscopy. Scanning electron microscopic study of the wings of Common Emigrant butterfly showed that three different types of scales are present on the wing surface dorsally. Diffracting structures are present in certain parts of the surfaces of the various scales. Bead like structures are embedded in the intricate structures of the scales. Absorption spectra revealed that a strong absorption peak is seen in the UV-range. Crystalline structure of beads was confirmed by the X-ray diffraction analysis.

  15. Common sequence variants in the LOXL1 gene in pigment dispersion syndrome and pigmentary glaucoma.

    Science.gov (United States)

    Giardina, Emiliano; Oddone, Francesco; Lepre, Tiziana; Centofanti, Marco; Peconi, Cristina; Tanga, Lucia; Quaranta, Luciano; Frezzotti, Paolo; Novelli, Giuseppe; Manni, Gianluca

    2014-04-16

    Single nucleotide polymorphisms (SNPs) within the LOXL1 gene are associated with pseudoesfoliation syndrome and pseudoesfoliation glaucoma. The aim of our study is to investigate a potential involvement of LOXL1 gene in the pathogenesis of pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG). A cohort of Caucasian origin of 84 unrelated and clinically well-characterised patients with PDS/PG and 200 control subjects were included in the study. Genomic DNA from whole blood was extracted and the coding and regulatory regions of LOXL1 gene were risequenced in both patients and controls to identify unknown sequence variations. Genotype and haplotype analysis were performed with UNPHASED software. The expression levels of LOXL1 were determined on c-DNA from peripheral blood lymphocytes by quantitative real-time RT-PCR. A significant allele association was detected for SNP rs2304722 within the fifth intron of LOXL1 (Odds ratio (OR = 2.43, p-value = 3,05e-2). Haplotype analysis revealed the existence of risk and protective haplotypes associated with PG-PDS (OR = 3.35; p-value = 1.00e-5 and OR = 3.35; p-value = 1.00e-4, respectively). Expression analysis suggests that associated haplotypes can regulate the expression level LOXL1. Haplotypes of LOXL1 are associated with PG-PDS independently from rs1048661, leading to a differential expression of the transcript.

  16. IRIS PRA preliminary results and future direction

    International Nuclear Information System (INIS)

    Finnicum, D.J.; Kling, C.L.; Carelli, M.D.

    2004-01-01

    Westinghouse is currently conducting the pre-application licensing of the International Reactor Innovative and Secure (IRIS) on behalf of the IRIS Consortium. One of the key aspects of the IRIS design is the concept of safety-by-design. The PRA (Probabilistic Risk Analysis) is being used as an integral part of the design process. As part of this effort, a PRA of the initial design was generated to address 2 key areas. First, the IRIS PRA supported the evaluation of IRIS design issues by providing a solid risk basis for design and analyses required for the pre-licensing evaluation of the IRIS design. The PRA provides the tool for quantifying the benefit of the safety-by-design approach. Second, the current PRA task is beginning the preparation of the more complete PRA analyses and documentation eventually required for Design Certification. One of the key risk-related goals for IRIS is to reduce the EPZ (Emergency Protection Zone) to within the exclusion area by demonstrating that the off-site doses are consistent with the US Protective Action Guidelines (PAGs) for initiation of emergency response so that the required protective actions would be limited to the exclusion area. The results of the preliminary PRA indicated a core damage frequency of 1.2 E-08 for internal initiators. This is a very good result but much work is needed to meet the ambitious goal of no emergency response. The next phase of the PRA analyses will involve a two-fold expansion of the PRA. First, as the design and analyses approach a greater level of detail, the assumptions used for the initial PRA will be reviewed and the models will be revised as needed to reflect the improved knowledge of the system design and performance. Furthermore, as the full plant design advances, the PRA will be expanded to incorporate risk associated with external challenges such as seismic and fire, and to address low power and shutdowns modes of operation. As with the initial work, the PRA will serve as a tool to

  17. Revision of IRIS/IDA Seismic Station Metadata

    Science.gov (United States)

    Xu, W.; Davis, P.; Auerbach, D.; Klimczak, E.

    2017-12-01

    Trustworthy data quality assurance has always been one of the goals of seismic network operators and data management centers. This task is considerably complex and evolving due to the huge quantities as well as the rapidly changing characteristics and complexities of seismic data. Published metadata usually reflect instrument response characteristics and their accuracies, which includes zero frequency sensitivity for both seismometer and data logger as well as other, frequency-dependent elements. In this work, we are mainly focused studying the variation of the seismometer sensitivity with time of IRIS/IDA seismic recording systems with a goal to improve the metadata accuracy for the history of the network. There are several ways to measure the accuracy of seismometer sensitivity for the seismic stations in service. An effective practice recently developed is to collocate a reference seismometer in proximity to verify the in-situ sensors' calibration. For those stations with a secondary broadband seismometer, IRIS' MUSTANG metric computation system introduced a transfer function metric to reflect two sensors' gain ratios in the microseism frequency band. In addition, a simulation approach based on M2 tidal measurements has been proposed and proven to be effective. In this work, we compare and analyze the results from three different methods, and concluded that the collocated-sensor method is most stable and reliable with the minimum uncertainties all the time. However, for epochs without both the collocated sensor and secondary seismometer, we rely on the analysis results from tide method. For the data since 1992 on IDA stations, we computed over 600 revised seismometer sensitivities for all the IRIS/IDA network calibration epochs. Hopefully further revision procedures will help to guarantee that the data is accurately reflected by the metadata of these stations.

  18. Checking the new IRI model: The bottomside B parameters

    International Nuclear Information System (INIS)

    Mosert, M.; Buresova, D.; Miro, G.; Lazo, B.; Ezquer, R.

    2003-01-01

    Electron density profiles obtained at Pruhonice (50.0, 15.0), El Arenosillo (37.1, 353.2) and Havana (23, 278) were used to check the bottom-side B parameters BO (thickness parameter) and B1 (shape parameter) predicted by the new IRI - 2000 version. The electron density profiles were derived from ionograms using the ARP technique. The data base includes daytime and nighttime ionograms recorded under different seasonal and solar activity conditions. Comparisons with IRI predictions were also done. The analysis shows that: a) The parameter B1 given by IRI 2000 reproduces better the observed ARP values than the IRI-90 version and b) The observed BO values are in general well reproduced by both IRI versions: IRI-90 and IRI-2000. (author)

  19. IRIS Toxicological Review of Benzo[a]pyrene (Interagency ...

    Science.gov (United States)

    In January 2017, EPA finalized the IRIS assessment of Benzo[a]pyrene. The Toxicological Review was reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science discussion materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Benzo[a]pyrene are posted on this site. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for benzo[a]pyrene (BaP). The outcome of this project is an updated Toxicological Review and IRIS Summary for BaP that will be entered into the IRIS database.

  20. Toward noncooperative iris recognition: a classification approach using multiple signatures.

    Science.gov (United States)

    Proença, Hugo; Alexandre, Luís A

    2007-04-01

    This paper focuses on noncooperative iris recognition, i.e., the capture of iris images at large distances, under less controlled lighting conditions, and without active participation of the subjects. This increases the probability of capturing very heterogeneous images (regarding focus, contrast, or brightness) and with several noise factors (iris obstructions and reflections). Current iris recognition systems are unable to deal with noisy data and substantially increase their error rates, especially the false rejections, in these conditions. We propose an iris classification method that divides the segmented and normalized iris image into six regions, makes an independent feature extraction and comparison for each region, and combines each of the dissimilarity values through a classification rule. Experiments show a substantial decrease, higher than 40 percent, of the false rejection rates in the recognition of noisy iris images.

  1. Checking the new IRI model The bottomside B parameters

    CERN Document Server

    Mosert, M; Ezquer, R; Lazo, B; Miro, G

    2002-01-01

    Electron density profiles obtained at Pruhonice (50.0, 15.0), El Arenosillo (37.1, 353.2) and Havana (23, 278) were used to check the bottom-side B parameters BO (thickness parameter) and B1 (shape parameter) predicted by the new IRI - 2000 version. The electron density profiles were derived from ionograms using the ARP technique. The data base includes daytime and nighttime ionograms recorded under different seasonal and solar activity conditions. Comparisons with IRI predictions were also done. The analysis shows that: a) The parameter B1 given by IRI 2000 reproduces better the observed ARP values than the IRI-90 version and b) The observed BO values are in general well reproduced by both IRI versions: IRI-90 and IRI-2000.

  2. IRIS: Proceeding Towards the Preliminary Design

    International Nuclear Information System (INIS)

    Carelli, M.; Miller, K.; Lombardi, C.; Todreas, N.; Greenspan, E.; Ninokata, H.; Lopez, F.; Cinotti, L.; Collado, J.; Oriolo, F.; Alonso, G.; Morales, M.; Boroughs, R.; Barroso, A.; Ingersoll, D.; Cavlina, N.

    2002-01-01

    The IRIS (International Reactor Innovative and Secure) project has completed the conceptual design phase and is moving towards completion of the preliminary design, scheduled for the end of 2002. Several other papers presented in this conference provide details on major aspects of the IRIS design. The three most innovative features which uniquely characterize IRIS are, in descending order of impact: 1. Safety-by-design, which takes maximum advantage of the integral configuration to eliminate from consideration some accidents, greatly lessen the consequence of other accident scenarios and decrease their probability of occurring; 2. Optimized maintenance, where the interval between maintenance shutdowns is extended to 48 months; and 3. Long core life, of at least four years without shuffling or partial refueling. Regarding feature 1, design and analyses will be supplemented by an extensive testing campaign to verify and demonstrate the performance of the integral components, individually as well as interactive systems. Test planning is being initiated. Test results will be factored into PRA analyses under an overall risk informed regulation approach, which is planned to be used in the IRIS licensing. Pre-application activities with NRC are also scheduled to start in mid 2002. Regarding feature 2, effort is being focused on advanced online diagnostics for the integral components, first of all the steam generators, which are the most critical component; several techniques are being investigated. Finally, a four year long life core design is well underway and some of the IRIS team members are examining higher enrichment, eight to ten year life cores which could be considered for reloads. (authors)

  3. IRIS. Progress in licensing and toward deployment

    International Nuclear Information System (INIS)

    Petrovic, B.; Carelli, M.D.; Kling, C.L.; Cavlina, N.; Grgic, D.

    2006-01-01

    The International Reactor Innovative and Secure (IRIS) is an advanced, integral, light water cooled, pressurized reactor of smaller generating capacity (1000 MWt, or 335 MWe). It is being developed through a strong international partnership by a team lead by Westinghouse and including organizations from 10 countries. The main objective of the project is to offer a simple nuclear power plant with outstanding safety, attractive economics and enhanced proliferation resistance characteristics ready for deployment within the next decade. IRIS embodies the requirements set forth by the recently announced US DOE Global Nuclear Energy Partnership (GNEP) program for worldwide deployment of a smaller-scale reactors and provides a viable bridge to Generation IV reactors. IRIS is designed to address the needs of both developed and emerging markets. Its smaller power level provides deployment flexibility in larger developed markets, and makes it in particular well suited for markets with limited grids or where the annual energy demand growth is moderate. Due to its short construction time and the staggered build option, IRIS significantly reduces the required financing, improves cash flow, and provides a viable solution for economies with limited resources. While based on proven and worldwide accepted LWR technology, IRIS introduces a number of innovative solutions to simplify its design and improve safety and operational characteristics, including the integral primary system and its components, as well as the safety-by-design approach. These features will be tested and demonstrated in a testing program that has been initiated. As its centerpiece, the program will include the integral test facility. Results of this program will support licensing with the US NRC. A multinational licensing is considered to facilitate worldwide deployment. (author)

  4. Combining GPS measurements and IRI model predictions

    International Nuclear Information System (INIS)

    Hernandez-Pajares, M.; Juan, J.M.; Sanz, J.; Bilitza, D.

    2002-01-01

    The free electrons distributed in the ionosphere (between one hundred and thousands of km in height) produce a frequency-dependent effect on Global Positioning System (GPS) signals: a delay in the pseudo-orange and an advance in the carrier phase. These effects are proportional to the columnar electron density between the satellite and receiver, i.e. the integrated electron density along the ray path. Global ionospheric TEC (total electron content) maps can be obtained with GPS data from a network of ground IGS (international GPS service) reference stations with an accuracy of few TEC units. The comparison with the TOPEX TEC, mainly measured over the oceans far from the IGS stations, shows a mean bias and standard deviation of about 2 and 5 TECUs respectively. The discrepancies between the STEC predictions and the observed values show an RMS typically below 5 TECUs (which also includes the alignment code noise). he existence of a growing database 2-hourly global TEC maps and with resolution of 5x2.5 degrees in longitude and latitude can be used to improve the IRI prediction capability of the TEC. When the IRI predictions and the GPS estimations are compared for a three month period around the Solar Maximum, they are in good agreement for middle latitudes. An over-determination of IRI TEC has been found at the extreme latitudes, the IRI predictions being, typically two times higher than the GPS estimations. Finally, local fits of the IRI model can be done by tuning the SSN from STEC GPS observations

  5. Effective Solar Indices for Ionospheric Modeling: A Review and a Proposal for a Real-Time Regional IRI

    Science.gov (United States)

    Pignalberi, A.; Pezzopane, M.; Rizzi, R.; Galkin, I.

    2018-01-01

    The first part of this paper reviews methods using effective solar indices to update a background ionospheric model focusing on those employing the Kriging method to perform the spatial interpolation. Then, it proposes a method to update the International Reference Ionosphere (IRI) model through the assimilation of data collected by a European ionosonde network. The method, called International Reference Ionosphere UPdate (IRI UP), that can potentially operate in real time, is mathematically described and validated for the period 9-25 March 2015 (a time window including the well-known St. Patrick storm occurred on 17 March), using IRI and IRI Real Time Assimilative Model (IRTAM) models as the reference. It relies on foF2 and M(3000)F2 ionospheric characteristics, recorded routinely by a network of 12 European ionosonde stations, which are used to calculate for each station effective values of IRI indices IG_{12} and R_{12} (identified as IG_{{12{eff}}} and R_{{12{eff}}}); then, starting from this discrete dataset of values, two-dimensional (2D) maps of IG_{{12{eff}}} and R_{{12{eff}}} are generated through the universal Kriging method. Five variogram models are proposed and tested statistically to select the best performer for each effective index. Then, computed maps of IG_{{12{eff}}} and R_{{12{eff}}} are used in the IRI model to synthesize updated values of foF2 and hmF2. To evaluate the ability of the proposed method to reproduce rapid local changes that are common under disturbed conditions, quality metrics are calculated for two test stations whose measurements were not assimilated in IRI UP, Fairford (51.7°N, 1.5°W) and San Vito (40.6°N, 17.8°E), for IRI, IRI UP, and IRTAM models. The proposed method turns out to be very effective under highly disturbed conditions, with significant improvements of the foF2 representation and noticeable improvements of the hmF2 one. Important improvements have been verified also for quiet and moderately disturbed

  6. Ten years of intraoperative floppy iris syndrome in the era of α-blockers

    Science.gov (United States)

    Mohamad Al-Ali, Badereddin; Radmayr, Christian; Weber, Maria; Horninger, Wolfgang; Findl, Oliver; Plas, Eugen

    2017-01-01

    Introduction The use of alpha-1 receptor antagonists in the treatment of benign prostatic hyperplasia (BPH) has created a problem in ophthalmic surgery, the so-called intraoperative floppy iris syndrome (IFIS). This consists of a billowing iris, insufficient pupillary dilation with progressive intraoperative miosis, and protrusion of iris tissue through the tunnel and side port incision that are made for access to the anterior chamber during surgery. IFIS presents particular difficulties in cataract surgery which is carried out through the pupil with manipulations in the immediate vicinity of the iris. The complications range from poor visibility of the operative field to iris damage with the surgical instruments and to rupture of the posterior capsule, with loss of lens material into the vitreous body. Material and methods A comprehensive literature review was performed using MEDLINE with MeSH terms and keywords ‘benign prostatic hyperplasia’, ‘intraoperative floppy iris syndrome’, ‘adrenergic alpha-antagonist’ and ‘cataract surgery’. In addition, reference lists from identified publications were reviewed to identify reports and studies of interest from 2001 to 2017. Results The A total of 95% of experienced ophthalmologic surgeons reported that systematic treatment with tamsulosin represents a challenging surgical condition increasing the risk of complications. Alpha-blockers are commonly prescribed, with 1,079,505 packages of tamsulosin prescribed each month in 2014 in Austria. Dose modification may be one way to reduce the risk of IFIS. A lower incidence of IFIS was reported in patients on tamsulosin in Japan, but the recommended dosage was lower than that used in Europe and the US (0.2 mg vs. 0.4 mg). Conclusions We showed that not all patients taking tamsulosin experience IFIS. Moreover, larger investigations with a prospective design are needed, including studies to monitor the pre- and post-therapeutic ophthalmologic changes under tamsulosin

  7. Genetic Analyses of a Three Generation Family Segregating Hirschsprung Disease and Iris Heterochromia.

    Directory of Open Access Journals (Sweden)

    Long Cui

    Full Text Available We present the genetic analyses conducted on a three-generation family (14 individuals with three members affected with isolated-Hirschsprung disease (HSCR and one with HSCR and heterochromia iridum (syndromic-HSCR, a phenotype reminiscent of Waardenburg-Shah syndrome (WS4. WS4 is characterized by pigmentary abnormalities of the skin, eyes and/or hair, sensorineural deafness and HSCR. None of the members had sensorineural deafness. The family was screened for copy number variations (CNVs using Illumina-HumanOmni2.5-Beadchip and for coding sequence mutations in WS4 genes (EDN3, EDNRB, or SOX10 and in the main HSCR gene (RET. Confocal microscopy and immunoblotting were used to assess the functional impact of the mutations. A heterozygous A/G transition in EDNRB was identified in 4 affected and 3 unaffected individuals. While in EDNRB isoforms 1 and 2 (cellular receptor the transition results in the abolishment of translation initiation (M1V, in isoform 3 (only in the cytosol the replacement occurs at Met91 (M91V and is predicted benign. Another heterozygous transition (c.-248G/A; -predicted to affect translation efficiency- in the 5'-untranslated region of EDN3 (EDNRB ligand was detected in all affected individuals but not in healthy carriers of the EDNRB mutation. Also, a de novo CNVs encompassing DACH1 was identified in the patient with heterochromia iridum and HSCR Since the EDNRB and EDN3 variants only coexist in affected individuals, HSCR could be due to the joint effect of mutations in genes of the same pathway. Iris heterochromia could be due to an independent genetic event and would account for the additional phenotype within the family.

  8. IRIS design overview and status update

    International Nuclear Information System (INIS)

    Carelli, M.D.; Petrovic, B.; Conway, L.E.; Oriani, L.; Kling, C.L.; Miller, K.; Lombardi, C.V.; Ricotti, M.E.; Barroso, A.C.O.; Collado, J.M.; Cinotti, L.; Storai, S.; Berra, F.; Todreas, N.E.; Ninokata, H.; Cavlina, N.; Grgic, D.; Oriolo, F.; Moraes, M.M.; Frederico, C.; Henning, F.; Griffith, W.; Love, J.; Ingersoll, D.T.; Wood, R.; Alonso, G.; Kodochigov, N.; Polunichev, V.; Augutis, J.; Alzbutas, R.; Boroughs, R.D.; Naviglio, A.; Panella, B.

    2005-01-01

    The International Reactor Innovative and Secure (IRIS) is an advanced, integral, light-water cooled reactor of medium generating capacity (1000 MWt, or ∼335 MWe), geared at near term deployment (2012- 2015). It has been under development since the turn of the century by an international consortium--led by Westinghouse--that includes 21 organizations from 10 countries, and it is currently in the pre-application licensing process with the U.S. Nuclear Regulatory Commission (NRC). This paper describes its integral design (i.e., steam generators, pumps, pressurizer and control rod drive mechanisms are all included inside the reactor vessel, together with the core, control rods, and neutron reflector/shield) and discusses the unique ('safety-by-design') TM IRIS philosophy. This approach, by eliminating accidents at the design stage, or decreasing their consequences and probabilities when outright elimination is not possible, provides a very powerful first level of defense in depth. The ('safety by- design') TM allows a significant reduction and simplification of the passive safety systems, which not only improves safety but simultaneously reduces the overall cost. Moreover, it supports licensing the power plant without the need for off-site emergency response planning--an objective which is part of the pre-application with NRC and is also pursued within an international research project coordinated by the International Atomic Energy Agency (IAEA). This would allow IRIS to be treated as any other industrial facility, located closer to population centers, and enable its effective dual-purpose use for electricity production and co-generation (district heating, desalination, industrial steam). The modular IRIS--with each module rated at ∼335 MWe--is an ideal size for developing countries as it allows to easily introducing single modules in regions only requiring a few hundred MWs, or a moderate amount of power on limited electric grids. IRIS can be also deployed in

  9. IRIS COLOUR CLASSIFICATION SCALES--THEN AND NOW.

    Science.gov (United States)

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual's eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale.

  10. Iris Recognition Using Feature Extraction of Box Counting Fractal Dimension

    Science.gov (United States)

    Khotimah, C.; Juniati, D.

    2018-01-01

    Biometrics is a science that is now growing rapidly. Iris recognition is a biometric modality which captures a photo of the eye pattern. The markings of the iris are distinctive that it has been proposed to use as a means of identification, instead of fingerprints. Iris recognition was chosen for identification in this research because every human has a special feature that each individual is different and the iris is protected by the cornea so that it will have a fixed shape. This iris recognition consists of three step: pre-processing of data, feature extraction, and feature matching. Hough transformation is used in the process of pre-processing to locate the iris area and Daugman’s rubber sheet model to normalize the iris data set into rectangular blocks. To find the characteristics of the iris, it was used box counting method to get the fractal dimension value of the iris. Tests carried out by used k-fold cross method with k = 5. In each test used 10 different grade K of K-Nearest Neighbor (KNN). The result of iris recognition was obtained with the best accuracy was 92,63 % for K = 3 value on K-Nearest Neighbor (KNN) method.

  11. IRIS COLOUR CLASSIFICATION SCALES – THEN AND NOW

    Science.gov (United States)

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual’s eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale. PMID:27373112

  12. Longwing (Heliconius) butterflies combine a restricted set of pigmentary and structural coloration mechanisms.

    Science.gov (United States)

    Wilts, Bodo D; Vey, Aidan J M; Briscoe, Adriana D; Stavenga, Doekele G

    2017-11-21

    Longwing butterflies, Heliconius sp., also called heliconians, are striking examples of diversity and mimicry in butterflies. Heliconians feature strongly colored patterns on their wings, arising from wing scales colored by pigments and/or nanostructures, which serve as an aposematic signal. Here, we investigate the coloration mechanisms among several species of Heliconius by applying scanning electron microscopy, (micro)spectrophotometry, and imaging scatterometry. We identify seven kinds of colored scales within Heliconius whose coloration is derived from pigments, nanostructures or both. In yellow-, orange- and red-colored wing patches, both cover and ground scales contain wavelength-selective absorbing pigments, 3-OH-kynurenine, xanthommatin and/or dihydroxanthommatin. In blue wing patches, the cover scales are blue either due to interference of light in the thin-film lower lamina (e.g., H. doris) or in the multilayered lamellae in the scale ridges (so-called ridge reflectors, e.g., H. sara and H. erato); the underlying ground scales are black. In the white wing patches, both cover and ground scales are blue due to their thin-film lower lamina, but because they are stacked upon each other and at the wing substrate, a faint bluish to white color results. Lastly, green wing patches (H. doris) have cover scales with blue-reflecting thin films and short-wavelength absorbing 3-OH-kynurenine, together causing a green color. The pigmentary and structural traits are discussed in relation to their phylogenetic distribution and the evolution of vision in this highly interesting clade of butterflies.

  13. Prosessiautomaation häiriösuojaus

    OpenAIRE

    Aalto, Joni

    2015-01-01

    Opinnäytetyön tarkoituksena oli tutustua prosessiteollisuuden automaatio- ja ohjausjärjestelmien häiriösuojaukseen ja varmistaa sen oikeanlainen rakenne ja toiminta käytännössä. Työ tehtiin Insta Automation Oy:lle, joka vastaa Boliden Harjavallan sähkökunnossapidosta ja sähkösuunnittelusta. Työ tehtiin Boliden Harjavallan sulaton alueella. Työhön kuului häiriöttömän eli TE-maadoituksen rakenteen tarkastaminen ja mittaus sekä prosessinohjaukseen käytettävän Metso DNA-järjestelmän sähköns...

  14. Preliminary core design of IRIS-50

    International Nuclear Information System (INIS)

    Petrovic, Bojan; Franceschini, Fausto

    2009-01-01

    IRIS-50 is a small, 50 MWe, advanced PWR with integral primary system. It evolved employing the same design principles as the well known medium size (335 MWe) IRIS. These principles include the 'safety-by-design' philosophy, simple and robust design, and deployment flexibility. The 50 MWe design addresses the needs of specific applications (e.g., power generation in small regional grids, water desalination and biodiesel production at remote locations, autonomous power source for special applications, etc.). Such applications may favor or even require longer refueling cycles, or may have some other specific requirements. Impact of these requirements on the core design and refueling strategy is discussed in the paper. Trade-off between the cycle length and other relevant parameters is addressed. A preliminary core design is presented, together with the core main reactor physics performance parameters. (author)

  15. Fuel management approach in IRIS Reactor

    International Nuclear Information System (INIS)

    Petrovic, B.; Franceschini, F.

    2004-01-01

    This paper provides an overview of fuel management approach employed in IRIS (International Reactor Innovative and Secure). It introduces the initial, rather ambitious, fuel management goals and discusses their evolution that reflected the fast pace of progress of the overall project. The updated objectives rely on using currently licensed fuel technology, thus enabling near-term deployment of IRIS, while still providing improved fuel utilization. The paper focuses on the reference core design and fuel management strategy that is considered in pre-application licensing, which enables extended cycle of three to four years. The extended cycle reduces maintenance outage time and increases capacity factor, thus reducing the cost of electricity. Approaches to achieving this goal are discussed, including use of different reloading strategies. Additional fuel management options, which are not part of the licensing process, but are pursued as long-term research for possible future implementation, are presented as well. (Author)

  16. [Cyclorotation of the eye in wavefront-guided LASIK using a static eyetracker with iris recognition].

    Science.gov (United States)

    Kohnen, T; Kühne, C; Cichocki, M; Strenger, A

    2007-01-01

    Centration of the ablation zone decisively influences the result of wavefront-guided LASIK. Cyclorotation of the eye occurs as the patient changes from the sitting position during aberrometry to the supine position during laser surgery and may lead to induction of lower and higher order aberrations. Twenty patients (40 eyes) underwent wavefront-guided LASIK (B&L 217z 100 excimer laser) with a static eyetracker driven by iris recognition (mean preoperative SE: -4.72+/-1.45 D; range: -1.63 to -7.00 D). The iris patterns of the patients' eyes were memorized during aberrometry and after flap creation. The mean absolute value of the measured cyclorotation was -1.5+/-4.2 degrees (range: -11.0 to 6.9 degrees ). The mean cyclorotation was 3.5+/-2.7 masculine (range: 0.1 to 11.0 degrees ). In 65% of all eyes cyclorotation was >2 masculine. A static eyetracker driven by iris recognition demonstrated that cyclorotation of up to 11 degrees may occur in myopic and myopic astigmatic eyes when changing from a sitting to a supine position. Use of static eyetrackers with iris recognition may provide a more precise positioning of the ablation profile as they detect and compensate cyclorotation.

  17. IRIS Toxicological Review of Trichloroacetic Acid (TCA) ...

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroacetic acid (TCA) that when finalized will appear on the Integrated Risk Information System (IRIS) database. The draft Toxicological Review of trichloroacetic acid provides scientific support and rationale for the hazard and dose-response assessment pertaining to chronic exposure to trichloroacetic acid.

  18. Unsupervised detection of non-iris occlusions

    Czech Academy of Sciences Publication Activity Database

    Haindl, Michal; Krupička, Mikuláš

    2015-01-01

    Roč. 57, č. 5 (2015), s. 60-65 ISSN 0167-8655 R&D Projects: GA ČR(CZ) GA14-10911S Institutional support: RVO:67985556 Keywords : Iris recognition * Color * Markov random field * Texture Subject RIV: BD - Theory of Information Impact factor: 1.586, year: 2015 http://library.utia.cas.cz/separaty/2015/RO/haindl-0444723.pdf

  19. Optical Coherence Tomography Angiography Characteristics of Iris Melanocytic Tumors

    Science.gov (United States)

    Skalet, Alison H.; Li, Yan; Lu, Chen D.; Jia, Yali; Lee, ByungKun; Husvogt, Lennart; Maier, Andreas; Fujimoto, James G.; Thomas, Charles R.; Huang, David

    2016-01-01

    Objective To evaluate tumor vasculature with optical coherence tomography (OCT) angiography (OCTA) in malignant iris melanomas and benign iris lesions. Design Cross-sectional observational clinical study. Participants Patients with iris lesions and healthy volunteers. Methods Eyes were imaged using OCTA systems operating at 1050 and 840 nm wavelengths. Three-dimensional OCTA scans were acquired. Iris melanomas patients treated with radiation therapy were imaged again after I-125 plaque brachytherapy at 6 and 18 months. Main Outcome Measures OCT and OCTA images, qualitative evaluation of iris and tumor vasculature and quantitative vessel density. Results One eye each of eight normal volunteers and nine patients with iris melanomas or benign iris lesions including freckles, nevi, and an iris pigment epithelial (IPE) cyst were imaged. The normal iris has radially-oriented vessels within the stroma on OCTA. Penetration of flow signal in normal iris depended on iris color, with best penetration seen in light to moderately pigmented irides. Iris melanomas demonstrated tortuous and disorganized intratumoral vasculature. In two eyes with nevi there was no increased vascularity; in another, fine vascular loops were noted near an area of ectropion uveae. Iris freckles and the IPE cyst did not have intrinsic vascularity. The vessel density was significantly higher within iris melanomas (34.5%±9.8%, piris nevi (8.0%±1.4%) or normal irides (8.0%±1.2%). Tumor regression after radiation therapy for melanomas was associated with decreased vessel density. OCTA at 1050 nm provided better visualization of tumor vasculature and penetration through thicker tumors than at 840 nm. But in very thick tumors and highly pigmented lesions even 1050 nm OCTA could not visualize their full thickness. Interpretable OCTA images were obtained in 82% participants in whom imaging was attempted. Conclusions This is the first demonstration of OCTA in iris tumors. OCTA may provide a dye-free, no

  20. Optimal Face-Iris Multimodal Fusion Scheme

    Directory of Open Access Journals (Sweden)

    Omid Sharifi

    2016-06-01

    Full Text Available Multimodal biometric systems are considered a way to minimize the limitations raised by single traits. This paper proposes new schemes based on score level, feature level and decision level fusion to efficiently fuse face and iris modalities. Log-Gabor transformation is applied as the feature extraction method on face and iris modalities. At each level of fusion, different schemes are proposed to improve the recognition performance and, finally, a combination of schemes at different fusion levels constructs an optimized and robust scheme. In this study, CASIA Iris Distance database is used to examine the robustness of all unimodal and multimodal schemes. In addition, Backtracking Search Algorithm (BSA, a novel population-based iterative evolutionary algorithm, is applied to improve the recognition accuracy of schemes by reducing the number of features and selecting the optimized weights for feature level and score level fusion, respectively. Experimental results on verification rates demonstrate a significant improvement of proposed fusion schemes over unimodal and multimodal fusion methods.

  1. [Analysis of iris: history and future].

    Science.gov (United States)

    Norn, Mogens

    2003-01-01

    Analysis of the iris has ancient roots, but iridology in its present sense was established by Philippi Meyers in 1670. The discipline was further developed by Ignaz Péczely in 1881 and by Nils Liljequist in 1890. Other studies have been published in Germany, Sweden, Norway, England, France, USA, Australia and elsewhere, and iridology is practiced worldwide. The techniques used are described and the sources of error are mentioned when several photos from the same patient are compared (e.g. the influences of differences in pupil size, magnification and the effect of oblique light). The iris key (irigraphy) and the interpretation of different sights are discussed in some detail; there is little agreement among iridologists. Some iris diagnoses are of little interest to day and some modern diseases are missing in the diagnostic system. Controlled studies reveal that iridology is of no use whatsoever for the detection of cancer and other diseases in the stomach, intestines, kidney, lungs and heart. The reason for the continued popularity of iridology is discussed, and it is concluded that this type of alternative medicine is not harmless.

  2. Optimal wavelength band clustering for multispectral iris recognition.

    Science.gov (United States)

    Gong, Yazhuo; Zhang, David; Shi, Pengfei; Yan, Jingqi

    2012-07-01

    This work explores the possibility of clustering spectral wavelengths based on the maximum dissimilarity of iris textures. The eventual goal is to determine how many bands of spectral wavelengths will be enough for iris multispectral fusion and to find these bands that will provide higher performance of iris multispectral recognition. A multispectral acquisition system was first designed for imaging the iris at narrow spectral bands in the range of 420 to 940 nm. Next, a set of 60 human iris images that correspond to the right and left eyes of 30 different subjects were acquired for an analysis. Finally, we determined that 3 clusters were enough to represent the 10 feature bands of spectral wavelengths using the agglomerative clustering based on two-dimensional principal component analysis. The experimental results suggest (1) the number, center, and composition of clusters of spectral wavelengths and (2) the higher performance of iris multispectral recognition based on a three wavelengths-bands fusion.

  3. Iris image recognition wavelet filter-banks based iris feature extraction schemes

    CERN Document Server

    Rahulkar, Amol D

    2014-01-01

    This book provides the new results in wavelet filter banks based feature extraction, and the classifier in the field of iris image recognition. It provides the broad treatment on the design of separable, non-separable wavelets filter banks, and the classifier. The design techniques presented in the book are applied on iris image analysis for person authentication. This book also brings together the three strands of research (wavelets, iris image analysis, and classifier). It compares the performance of the presented techniques with state-of-the-art available schemes. This book contains the compilation of basic material on the design of wavelets that avoids reading many different books. Therefore, it provide an easier path for the new-comers, researchers to master the contents. In addition, the designed filter banks and classifier can also be effectively used than existing filter-banks in many signal processing applications like pattern classification, data-compression, watermarking, denoising etc.  that will...

  4. Gabor Weber Local Descriptor for Bovine Iris Recognition

    OpenAIRE

    Sun, Shengnan; Zhao, Lindu; Yang, Shicai

    2013-01-01

    Iris recognition is a robust biometric technology. This paper proposes a novel local descriptor for bovine iris recognition, named Gabor Weber local descriptor (GWLD). We first compute the Gabor magnitude maps for the input bovine iris image, and then calculate the differential excitation and orientation for each pixel over each Gabor magnitude map. After that, we use these differential excitations and orientations to construct the GWLD histogram representation. Finally, histogram intersectio...

  5. HyspIRI Low Latency Concept and Benchmarks

    Science.gov (United States)

    Mandl, Dan

    2010-01-01

    Topics include HyspIRI low latency data ops concept, HyspIRI data flow, ongoing efforts, experiment with Web Coverage Processing Service (WCPS) approach to injecting new algorithms into SensorWeb, low fidelity HyspIRI IPM testbed, compute cloud testbed, open cloud testbed environment, Global Lambda Integrated Facility (GLIF) and OCC collaboration with Starlight, delay tolerant network (DTN) protocol benchmarking, and EO-1 configuration for preliminary DTN prototype.

  6. Preliminary ATWS analysis for the IRIS PRA

    International Nuclear Information System (INIS)

    Maddalena Barra; Marco S Ghisu; David J Finnicum; Luca Oriani

    2005-01-01

    Full text of publication follows: The pressurized light water cooled, medium power (1000 MWt) IRIS (International Reactor Innovative and Secure) has been under development for four years by an international consortium of over 21 organizations from ten countries. The plant conceptual design was completed in 2001 and the preliminary design is nearing completion. The pre-application licensing process with NRC started in October, 2002. IRIS has been primarily focused on establishing a design with innovative safety characteristics. The first line of defense in IRIS is to eliminate event initiators that could potentially lead to core damage. In IRIS, this concept is implemented through the 'safety by design' approach, which allows to minimize the number and complexity of the safety systems and required operator actions. The end result is a design with significantly reduced complexity and improved operability, and extensive plant simplifications to enhance construction. To support the optimization of the plant design and confirm the effectiveness of the safety by design approach in mitigating or eliminating events and thus providing a significant reduction in the probability of severe accidents, the PRA is being used as an integral part of the design process. A preliminary but extensive Level 1 PRA model has been developed to support the pre-application licensing of the IRIS design. As a result of the Preliminary IRIS PRA, an optimization of the design from a reliability point of view was completed, and an extremely low (about 1.2 E -8 ) core damage frequency (CDF) was assessed to confirm the impact of the safety by design approach. This first assessment is a result of a PRA model including internal initiating events. During this assessment, several assumptions were necessary to complete the CDF evaluation. In particular Anticipated Transients Without Scram (ATWS) were not included in this initial assessment, because their contribution to core damage frequency was assumed

  7. Iris double recognition based on modified evolutionary neural network

    Science.gov (United States)

    Liu, Shuai; Liu, Yuan-Ning; Zhu, Xiao-Dong; Huo, Guang; Liu, Wen-Tao; Feng, Jia-Kai

    2017-11-01

    Aiming at multicategory iris recognition under illumination and noise interference, this paper proposes a method of iris double recognition based on a modified evolutionary neural network. An equalization histogram and Laplace of Gaussian operator are used to process the iris to suppress illumination and noise interference and Haar wavelet to convert the iris feature to binary feature encoding. Calculate the Hamming distance for the test iris and template iris , and compare with classification threshold, determine the type of iris. If the iris cannot be identified as a different type, there needs to be a secondary recognition. The connection weights in back-propagation (BP) neural network use modified evolutionary neural network to adaptively train. The modified neural network is composed of particle swarm optimization with mutation operator and BP neural network. According to different iris libraries in different circumstances of experimental results, under illumination and noise interference, the correct recognition rate of this algorithm is higher, the ROC curve is closer to the coordinate axis, the training and recognition time is shorter, and the stability and the robustness are better.

  8. An iris recognition algorithm based on DCT and GLCM

    Science.gov (United States)

    Feng, G.; Wu, Ye-qing

    2008-04-01

    With the enlargement of mankind's activity range, the significance for person's status identity is becoming more and more important. So many different techniques for person's status identity were proposed for this practical usage. Conventional person's status identity methods like password and identification card are not always reliable. A wide variety of biometrics has been developed for this challenge. Among those biologic characteristics, iris pattern gains increasing attention for its stability, reliability, uniqueness, noninvasiveness and difficult to counterfeit. The distinct merits of the iris lead to its high reliability for personal identification. So the iris identification technique had become hot research point in the past several years. This paper presents an efficient algorithm for iris recognition using gray-level co-occurrence matrix(GLCM) and Discrete Cosine transform(DCT). To obtain more representative iris features, features from space and DCT transformation domain are extracted. Both GLCM and DCT are applied on the iris image to form the feature sequence in this paper. The combination of GLCM and DCT makes the iris feature more distinct. Upon GLCM and DCT the eigenvector of iris extracted, which reflects features of spatial transformation and frequency transformation. Experimental results show that the algorithm is effective and feasible with iris recognition.

  9. Multispectral diagnostic imaging of the iris in pigment dispersion syndrome.

    Science.gov (United States)

    Roberts, Daniel K; Lukic, Ana; Yang, Yongyi; Wilensky, Jacob T; Wernick, Miles N

    2012-08-01

    To determine if wavelength selection with near infrared iris imaging may enhance iris transillumination defects (ITDs) in pigment dispersion syndrome. An experimental apparatus was used to acquire iris images in 6 African-American (AA) and 6 White patients with pigment dispersion syndrome. Light-emitting diode probes of 6 different spectral bands (700 to 950 nm) were used to project light into patients' eyes. Iris patterns were photographed, ITD regions of interest were outlined, and region of interest contrasts were calculated for each spectral band. Contrasts varied as a function of wavelength (Ppigmented eyes may be slightly longer than for less pigmented eyes.

  10. Iris Transponder-Communications and Navigation for Deep Space

    Science.gov (United States)

    Duncan, Courtney B.; Smith, Amy E.; Aguirre, Fernando H.

    2014-01-01

    The Jet Propulsion Laboratory has developed the Iris CubeSat compatible deep space transponder for INSPIRE, the first CubeSat to deep space. Iris is 0.4 U, 0.4 kg, consumes 12.8 W, and interoperates with NASA's Deep Space Network (DSN) on X-Band frequencies (7.2 GHz uplink, 8.4 GHz downlink) for command, telemetry, and navigation. This talk discusses the Iris for INSPIRE, it's features and requirements; future developments and improvements underway; deep space and proximity operations applications for Iris; high rate earth orbit variants; and ground requirements, such as are implemented in the DSN, for deep space operations.

  11. Spatula scaffold: An iris-sparing technique for lensectomy.

    Science.gov (United States)

    Narang, Priya; Agarwal, Amar

    2017-12-01

    Lensectomy with vitrectomy is often performed for crystalline lenticular subluxation. We report a new technique and a practical approach that involves the placement of a spatula beneath the iris tissue that facilitates retroiridial removal of subluxated lens and acts as a scaffold by protecting the iris tissue from being accidentally trapped into the vitrectomy cutter port. Our technique facilitates management of the lens and vitreous without any trauma to the iris and secondarily obviates the need to perform an iris repair procedure that may arise due to iatrogenic reasons.

  12. Extending the imaging volume for biometric iris recognition.

    Science.gov (United States)

    Narayanswamy, Ramkumar; Johnson, Gregory E; Silveira, Paulo E X; Wach, Hans B

    2005-02-10

    The use of the human iris as a biometric has recently attracted significant interest in the area of security applications. The need to capture an iris without active user cooperation places demands on the optical system. Unlike a traditional optical design, in which a large imaging volume is traded off for diminished imaging resolution and capacity for collecting light, Wavefront Coded imaging is a computational imaging technology capable of expanding the imaging volume while maintaining an accurate and robust iris identification capability. We apply Wavefront Coded imaging to extend the imaging volume of the iris recognition application.

  13. Gabor Weber Local Descriptor for Bovine Iris Recognition

    Directory of Open Access Journals (Sweden)

    Shengnan Sun

    2013-01-01

    Full Text Available Iris recognition is a robust biometric technology. This paper proposes a novel local descriptor for bovine iris recognition, named Gabor Weber local descriptor (GWLD. We first compute the Gabor magnitude maps for the input bovine iris image, and then calculate the differential excitation and orientation for each pixel over each Gabor magnitude map. After that, we use these differential excitations and orientations to construct the GWLD histogram representation. Finally, histogram intersection is adopted to measure the similarity between different GWLD histograms. The experimental results on the SEU bovine iris database verify the representation power of our proposed local descriptor.

  14. Multispectral iris recognition based on group selection and game theory

    Science.gov (United States)

    Ahmad, Foysal; Roy, Kaushik

    2017-05-01

    A commercially available iris recognition system uses only a narrow band of the near infrared spectrum (700-900 nm) while iris images captured in the wide range of 405 nm to 1550 nm offer potential benefits to enhance recognition performance of an iris biometric system. The novelty of this research is that a group selection algorithm based on coalition game theory is explored to select the best patch subsets. In this algorithm, patches are divided into several groups based on their maximum contribution in different groups. Shapley values are used to evaluate the contribution of patches in different groups. Results show that this group selection based iris recognition

  15. Iris recognition in the presence of ocular disease.

    Science.gov (United States)

    Aslam, Tariq Mehmood; Tan, Shi Zhuan; Dhillon, Baljean

    2009-05-06

    Iris recognition systems are among the most accurate of all biometric technologies with immense potential for use in worldwide security applications. This study examined the effect of eye pathology on iris recognition and in particular whether eye disease could cause iris recognition systems to fail. The experiment involved a prospective cohort of 54 patients with anterior segment eye disease who were seen at the acute referral unit of the Princess Alexandra Eye Pavilion in Edinburgh. Iris camera images were obtained from patients before treatment was commenced and again at follow-up appointments after treatment had been given. The principal outcome measure was that of mathematical difference in the iris recognition templates obtained from patients' eyes before and after treatment of the eye disease. Results showed that the performance of iris recognition was remarkably resilient to most ophthalmic disease states, including corneal oedema, iridotomies (laser puncture of iris) and conjunctivitis. Problems were, however, encountered in some patients with acute inflammation of the iris (iritis/anterior uveitis). The effects of a subject developing anterior uveitis may cause current recognition systems to fail. Those developing and deploying iris recognition should be aware of the potential problems that this could cause to this key biometric technology.

  16. Intraoperative floppy iris syndrome (IFIS): a practical approach to medical and surgical considerations in cataract extractions

    DEFF Research Database (Denmark)

    Storr-Paulsen, Allan; Nørregaard, Jens Christian; Børme, Kim Kamp

    2009-01-01

    Abstract. Intraoperative floppy iris syndrome (IFIS) during cataract surgery is characterized by iris fluttering, iris prolapse towards the incisions, and a progressive pupillary constriction leading to high rates of complications. The syndrome has been reported following the treatment of benign...

  17. Effect of tamsulosin on iris vasculature and morphology.

    Science.gov (United States)

    Shtein, Roni M; Hussain, Munira T; Cooney, Theresa M; Elner, Victor M; Hood, Christopher T

    2014-05-01

    To determine whether preoperative iris vasculature and morphology are altered in patients who have taken tamsulosin (Flomax). Academic multispecialty practice. Case series. Patients with current or past tamsulosin use and age- and sex-matched control patients were included. Anterior segment optical coherence tomography (AS-OCT) and iris fluorescein angiography were performed to measure iris vasculature and thickness before cataract surgery. Data collected at surgery included pupil diameter, clinical signs of intraoperative floppy-iris syndrome, and surgical complications. Tamsulosin was currently used by 16 patients and in the past by 4 patients; the control group comprised 10 patients. Pharmacologically dilated pupil diameter was statistically significantly smaller preoperatively and immediately postoperatively in the tamsulosin group than in the control group (P=.009 and P=.003, respectively). There was a statistically significant decrease in pupil size intraoperatively in the tamsulosin group (P=.05) but not in the control group (P=.3). Iris-vasculature parameters, specifically time to first vessel fill and percentage of vessel fill on iris fluorescein angiography, were not significantly different between the 2 groups. The AS-OCT measurements of iris morphology were not statistically significantly different between the groups. No surgical complications occurred. No fluorescein dye leakage, staining, or other vascular anomalies were observed. Although there were differences in pupil measurements and intraoperative iris behavior between patients who had been on tamsulosin and control patients, there were no significant differences in iris vasculature on iris fluorescein angiography or in iris morphology on AS-OCT. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Effect of tamsulosin on iris vasculature and morphology

    Science.gov (United States)

    Shtein, Roni M.; Hussain, Munira T.; Cooney, Theresa M.; Elner, Victor M.; Hood, Christopher T.

    2015-01-01

    PURPOSE To determine whether preoperative iris vasculature and morphology are altered in patients who have taken tamsulosin (Flomax). SETTING Academic multispecialty practice. DESIGN Case series. METHODS Patients with current or past tamsulosin use and age- and sex-matched control patients were included. Anterior segment optical coherence tomography (AS-OCT) and iris fluorescein angiography were performed to measure iris vasculature and thickness before cataract surgery. Data collected at surgery included pupil diameter, clinical signs of intraoperative floppy-iris syndrome, and surgical complications. RESULTS Tamsulosin was currently used by 16 patients and in the past by 4 patients; the control group comprised 10 patients. Pharmacologically dilated pupil diameter was significantly smaller preoperatively and immediately postoperatively in the tamsulosin group than in the control group (P = .009 and P = .003, respectively). There was a statistically significant decrease in pupil size intraoperatively in the tamsulosin group (P = .05) but not in the control group (P = .3). Iris-vasculature parameters, specifically time to first vessel fill and percentage of vessel fill on iris fluorescein angiography, were not significantly different between the 2 groups. The AS-OCT measurements of iris morphology were not statistically significantly different between the groups. No surgical complications occurred. No fluorescein dye leakage, staining, or other vascular anomalies were observed. CONCLUSIONS Although there were differences in pupil measurements and intraoperative iris behavior between patients who had been on tamsulosin and control patients, there were no significant differences in iris vasculature on iris fluorescein angiography or in iris morphology on AS-OCT. PMID:24631201

  19. Evaluation of Genetic Diversity of Iris Genotypes (Iris spp Using ISSR

    Directory of Open Access Journals (Sweden)

    seyedeh zeinab attari

    2017-02-01

    Full Text Available Introduction: Some of Iris species are growing in different parts of the Iran as wild species. Iris species have important medicinal and horticultural properties. Understanding of the genetic variation within and between populations is essential for the establishment of effective and efficient methods for conservation of the plants. Genetic variation studies are fundamental for the management and conservation of this species. The use of molecular markers is a powerful tool in the genetic study of populations. The use of DNA marker, such as AFLP, SSR, RAPD and ISSR represents an alternative method in detection of polymorphism. ISSRs are highly variable, require less investment in time, money and labor than other methods. ISSR can generate higher percentages of polymorphic loci than other PCR methods. These can serve as an efficient tool for phylogenetic studies. ISSRs had reported that used in studies of cultivated species to produce genetic linkage maps and to determine the relatedness of lines of agriculturally important species. ISSR analysis involves the PCR amplification of regions between adjacent, inversely oriented microsatellites, using a single simple sequence repeat (SSR motifs (dinucleotide, trinucleotide, tetranucleotide or penta nucleotides. Therefore, little is known about the genetic variability of the Iranian Iris ssp .The objectives of this study were to evaluate genetic diversity among genotypes using ISSR markers and the degree of polymorphism generated from ISSR technique as a pre-requisite for their applicability to population genetics studies in Iris ssp. Materials and Methods: To evaluate genetic variations in some wild Iris genotypes, Iris kopetdaghensis ،Iris songarica and Iris fosteriana were collected from some parts of Khorasan province. Genomic DNA was extracted from young leaves following the cetyltrimethylammonium bromide (CTAB procedure. Extracted DNA concentration was quantified by using the spectrophotometer

  20. An unusual case of seed dispersal in an invasive aquatic; yellow flag iris (Iris pseudacorus)

    Science.gov (United States)

    Understanding reproductive mode of invasive plants can help managers plan more efficacious control. Invasive aquatics typically reproduce primarily through vegetative means. Yellow flag iris is an invasive plant species often growing as an emergent aquatic. There have been contradictory reports of i...

  1. CFD modeling of the IRIS pressurizer dynamic

    International Nuclear Information System (INIS)

    Sanz, Ronny R.; Montesinos, Maria E.; Garcia, Carlos; Bueno, Elizabeth D.; Mazaira, Leorlen R.; Bezerra, Jair L.; Lira, Carlos A.B. Oliveira

    2015-01-01

    Integral layout of nuclear reactor IRIS makes possible the elimination of the spray system, which is usually used to mitigate in-surge transient and also help to Boron homogenization. The study of transients with deficiencies in the Boron homogenization in this technology is very important, because they can cause disturbances in the reactor power and insert a strong reactivity in the core. The detailed knowledge of the behavior of multiphase multicomponent flows is challenging due to the complex phenomena and interactions at the interface. In this context, the CFD modeling is employed in the design of equipment in the nuclear industry as it allows predicting accidents or predicting their performance in dissimilar applications. The aim of the present research is to model the IRIS pressurizer's dynamic using the commercial CFD code CFX. A symmetric tri dimensional model equivalent to 1/8 of the total geometry was adopted to reduce mesh size and minimize processing time. The model considers the coexistence of four phases and also takes into account the heat losses. The relationships for interfacial mass, energy, and momentum transport are programmed and incorporated into CFX. Moreover, two subdomains and several additional variables are defined to monitoring the boron dilution sequences and condensation-evaporation rates in different control volumes. For transient states a non - equilibrium stratification in the pressurizer is considered. This paper discusses the model developed and the behavior of the system for representative transients sequences. The results of analyzed transients of IRIS can be applied to the design of pressurizer internal structures and components. (author)

  2. CFD modeling of the IRIS pressurizer dynamic

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, Ronny R.; Montesinos, Maria E.; Garcia, Carlos; Bueno, Elizabeth D.; Mazaira, Leorlen R., E-mail: rsanz@instec.cu, E-mail: mmontesi@instec.cu, E-mail: cgh@instec.cu, E-mail: leored1984@gmail.com [Instituto Superior de Tecnologias y Ciencias Aplicadas (InSTEC), La Habana (Cuba); Bezerra, Jair L.; Lira, Carlos A.B. Oliveira, E-mail: jair.lima@ufpe.br, E-mail: cabol@ufpe.br [Universida Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2015-07-01

    Integral layout of nuclear reactor IRIS makes possible the elimination of the spray system, which is usually used to mitigate in-surge transient and also help to Boron homogenization. The study of transients with deficiencies in the Boron homogenization in this technology is very important, because they can cause disturbances in the reactor power and insert a strong reactivity in the core. The detailed knowledge of the behavior of multiphase multicomponent flows is challenging due to the complex phenomena and interactions at the interface. In this context, the CFD modeling is employed in the design of equipment in the nuclear industry as it allows predicting accidents or predicting their performance in dissimilar applications. The aim of the present research is to model the IRIS pressurizer's dynamic using the commercial CFD code CFX. A symmetric tri dimensional model equivalent to 1/8 of the total geometry was adopted to reduce mesh size and minimize processing time. The model considers the coexistence of four phases and also takes into account the heat losses. The relationships for interfacial mass, energy, and momentum transport are programmed and incorporated into CFX. Moreover, two subdomains and several additional variables are defined to monitoring the boron dilution sequences and condensation-evaporation rates in different control volumes. For transient states a non - equilibrium stratification in the pressurizer is considered. This paper discusses the model developed and the behavior of the system for representative transients sequences. The results of analyzed transients of IRIS can be applied to the design of pressurizer internal structures and components. (author)

  3. Dom IRIS in njegova vloga v rehabilitaciji: Smart Home IRIS and its role in rehabilitation: Smart Home IRIS and its role in rehabilitation:

    OpenAIRE

    Jenko, Mojca; Ocepek, Julija; Zupan, Anton

    2010-01-01

    Smart Home IRIS is a demonstrative apartment, founded in 2008 on the basis of numerous European smart home projects. The aim of this study was to establish the role of Smart Home IRIS in improving quality of life for persons with disabilities and elderly in Slovenia and the satisfaction of persons who have already been involved in a treatment in it. We analyzed a satisfaction questionnaire of the treatment in Smart Home IRIS, sent to all patients in 2008 (79 in total), as well as the problems...

  4. Frontal view reconstruction for iris recognition

    Science.gov (United States)

    Santos-Villalobos, Hector J; Bolme, David S; Boehnen, Chris Bensing

    2015-02-17

    Iris recognition can be accomplished for a wide variety of eye images by correcting input images with an off-angle gaze. A variety of techniques, from limbus modeling, corneal refraction modeling, optical flows, and genetic algorithms can be used. A variety of techniques, including aspherical eye modeling, corneal refraction modeling, ray tracing, and the like can be employed. Precomputed transforms can enhance performance for use in commercial applications. With application of the technologies, images with significantly unfavorable gaze angles can be successfully recognized.

  5. Mapping of land cover in Northern California with simulated HyspIRI images

    Science.gov (United States)

    Clark, M. L.; Kilham, N. E.

    2014-12-01

    Land-cover maps are important science products needed for natural resource and ecosystem service management, biodiversity conservation planning, and assessing human-induced and natural drivers of land change. Most land-cover maps at regional to global scales are produced with remote sensing techniques applied to multispectral satellite imagery with 30-500 m pixel sizes (e.g., Landsat, MODIS). Hyperspectral, or imaging spectrometer, imagery measuring the visible to shortwave infrared regions (i.e., full range) of the spectrum have shown improved capacity to map plant species and coarser land-cover associations, yet techniques have not been widely tested at regional and greater spatial scales. The Hyperspectral Infrared Imager (HyspIRI) mission is a full-range hyperspectral and thermal satellite being considered for development by NASA (hyspiri.jpl.nasa.gov). A hyperspectral satellite, such as HyspIRI, will provide detailed spectral and temporal information at global scales that could greatly improve our ability to map land cover with greater class detail and spatial and temporal accuracy than possible with conventional multispectral satellites. The broad goal of our research is to assess multi-temporal, HyspIRI-like satellite imagery for improved land cover mapping across a range of environmental and anthropogenic gradients in California. In this study, we mapped FAO Land Cover Classification System (LCCS) classes over 30,000 km2 in Northern California using multi-temporal HyspIRI imagery simulated from the AVIRIS airborne sensor. The Random Forests classification was applied to predictor variables derived from the multi-temporal hyperspectral data and accuracies were compared to that from Landsat 8 OLI. Results indicate increased mapping accuracy using HyspIRI multi-temporal imagery, particularly in discriminating different forest life-form types, such as mixed conifer and broadleaf forests and open- and closed-canopy forests.

  6. Grading of Iris Color with an Extended Photographic Reference Set

    Directory of Open Access Journals (Sweden)

    Luuk Franssen

    2008-01-01

    Conclusion: The new method is promising to be more accurate than existing iris color classification systems in clinical situations where objective colorimetry-based systems are not available. The method may be useful to assess iris translucency and fundus reflectance as sources of variation in retinal straylight.

  7. Driving Simulator study for intelligent cooperative intersection safety system (IRIS)

    NARCIS (Netherlands)

    Vreeswijk, J.; Schendzielorz, T.; Mathias, P.; Feenstra, P.

    2008-01-01

    About forty percent of all accidents occur at intersections. The Intelligent Cooperative Intersection Safety system (IRIS), as part of the European research project SAFESPOT, is a roadside application and aims at minimizing the number of accidents at controlled and uncontrolled intersections. IRIS

  8. An enhanced iris recognition and authentication system using ...

    African Journals Online (AJOL)

    Iris recognition and authentication has a major issue in its code generation and verification accuracy, in order to enhance the authentication process, a binary bit sequence of iris is generated, which contain several vital information that is used to calculate the Mean Energy and Maximum Energy that goes into the eye with an ...

  9. Simplified safety and containment systems for the iris reactor

    International Nuclear Information System (INIS)

    Conway, L.E.; Lombardi, C.; Ricotti, M.; Oriani, L.

    2001-01-01

    The IRIS (International Reactor Innovative and Secure) is a 100 - 300 MW modular type pressurized water reactor supported by the U.S. DOE NERI Program. IRIS features a long-life core to provide proliferation resistance and to reduce the volume of spent fuel, as well as reduce maintenance requirements. IRIS utilizes an integral reactor vessel that contains all major primary system components. This integral reactor vessel makes it possible to reduce containment size; making the IRIS more cost competitive. IRIS is being designed to enhance reactor safety, and therefore a key aspect of the IRIS program is the development of the safety and containment systems. These systems are being designed to maximize containment integrity, prevent core uncover following postulated accidents, minimize the probability and consequences of severe accidents, and provide a significant simplification over current safety system designs. The design of the IRIS containment and safety systems has been identified and preliminary analyses have been completed. The IRIS safety concept employs some unique features that minimize the consequences of postulated design basis events. This paper will provide a description of the containment design and safety systems, and will summarize the analysis results. (author)

  10. IRIS Toxicological Review of Ammonia (Revised External Review Draft)

    Science.gov (United States)

    In August 2013, EPA submitted a revised draft IRIS assessment of ammonia to the agency's Science Advisory Board (SAB) and posted this draft on the IRIS website. EPA had previously released a draft of the assessment for public comment, held a public meeting about the draft, and ...

  11. Eclipse-Free-Time Assessment Tool for IRIS

    Science.gov (United States)

    Eagle, David

    2012-01-01

    IRIS_EFT is a scientific simulation that can be used to perform an Eclipse-Free- Time (EFT) assessment of IRIS (Infrared Imaging Surveyor) mission orbits. EFT is defined to be those time intervals longer than one day during which the IRIS spacecraft is not in the Earth s shadow. Program IRIS_EFT implements a special perturbation of orbital motion to numerically integrate Cowell's form of the system of differential equations. Shadow conditions are predicted by embedding this integrator within Brent s method for finding the root of a nonlinear equation. The IRIS_EFT software models the effects of the following types of orbit perturbations on the long-term evolution and shadow characteristics of IRIS mission orbits. (1) Non-spherical Earth gravity, (2) Atmospheric drag, (3) Point-mass gravity of the Sun, and (4) Point-mass gravity of the Moon. The objective of this effort was to create an in-house computer program that would perform eclipse-free-time analysis. of candidate IRIS spacecraft mission orbits in an accurate and timely fashion. The software is a suite of Fortran subroutines and data files organized as a "computational" engine that is used to accurately predict the long-term orbit evolution of IRIS mission orbits while searching for Earth shadow conditions.

  12. Iris Recognition for Partially Occluded Images: Methodology and Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    Poursaberi A

    2007-01-01

    Full Text Available Accurate iris detection is a crucial part of an iris recognition system. One of the main issues in iris segmentation is coping with occlusion that happens due to eyelids and eyelashes. In the literature, some various methods have been suggested to solve the occlusion problem. In this paper, two different segmentations of iris are presented. In the first algorithm, a circle is located around the pupil with an appropriate diameter. The iris area encircled by the circular boundary is used for recognition purposes then. In the second method, again a circle is located around the pupil with a larger diameter. This time, however, only the lower part of the encircled iris area is utilized for individual recognition. Wavelet-based texture features are used in the process. Hamming and harmonic mean distance classifiers are exploited as a mixed classifier in suggested algorithm. It is observed that relying on a smaller but more reliable part of the iris, though reducing the net amount of information, improves the overall performance. Experimental results on CASIA database show that our method has a promising performance with an accuracy of 99.31%. The sensitivity of the proposed method is analyzed versus contrast, illumination, and noise as well, where lower sensitivity to all factors is observed when the lower half of the iris is used for recognition.

  13. Unconstrained Iris Acquisition and Recognition Using COTS PTZ Camera

    Directory of Open Access Journals (Sweden)

    Venugopalan Shreyas

    2010-01-01

    Full Text Available Abstract Uniqueness of iris patterns among individuals has resulted in the ubiquity of iris recognition systems in virtual and physical spaces, at high security facilities around the globe. Traditional methods of acquiring iris patterns in commercial systems scan the iris when an individual is at a predetermined location in front of the scanner. Most state-of-the-art techniques for unconstrained iris acquisition in literature use expensive custom equipment and are composed of a multicamera setup, which is bulky, expensive, and requires calibration. This paper investigates a method of unconstrained iris acquisition and recognition using a single commercial off-the-shelf (COTS pan-tilt-zoom (PTZ camera, that is compact and that reduces the cost of the final system, compared to other proposed hierarchical multicomponent systems. We employ state-of-the-art techniques for face detection and a robust eye detection scheme using active shape models for accurate landmark localization. Additionally, our system alleviates the need for any calibration stage prior to its use. We present results using a database of iris images captured using our system, while operating in an unconstrained acquisition mode at 1.5 m standoff, yielding an iris diameter in the 150–200 pixels range.

  14. IRIS Toxicological Review of n-Butanol (External Review Draft ...

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of n-butanol that will appear in the Integrated Risk Information System (IRIS) database. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for n-butanol. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  15. Real-time image restoration for iris recognition systems.

    Science.gov (United States)

    Kang, Byung Jun; Park, Kang Ryoung

    2007-12-01

    In the field of biometrics, it has been reported that iris recognition techniques have shown high levels of accuracy because unique patterns of the human iris, which has very many degrees of freedom, are used. However, because conventional iris cameras have small depth-of-field (DOF) areas, input iris images can easily be blurred, which can lead to lower recognition performance, since iris patterns are transformed by the blurring caused by optical defocusing. To overcome these problems, an autofocusing camera can be used. However, this inevitably increases the cost, size, and complexity of the system. Therefore, we propose a new real-time iris image-restoration method, which can increase the camera's DOF without requiring any additional hardware. This paper presents five novelties as compared to previous works: 1) by excluding eyelash and eyelid regions, it is possible to obtain more accurate focus scores from input iris images; 2) the parameter of the point spread function (PSF) can be estimated in terms of camera optics and measured focus scores; therefore, parameter estimation is more accurate than it has been in previous research; 3) because the PSF parameter can be obtained by using a predetermined equation, iris image restoration can be done in real-time; 4) by using a constrained least square (CLS) restoration filter that considers noise, performance can be greatly enhanced; and 5) restoration accuracy can also be enhanced by estimating the weight value of the noise-regularization term of the CLS filter according to the amount of image blurring. Experimental results showed that iris recognition errors when using the proposed restoration method were greatly reduced as compared to those results achieved without restoration or those achieved using previous iris-restoration methods.

  16. Long-term Outcome of Argon Laser Peripheral Iridoplasty in the Management of Plateau Iris Syndrome Eyes.

    Science.gov (United States)

    Peterson, Jeffrey R; Anderson, John W; Blieden, Lauren S; Chuang, Alice Z; Feldman, Robert M; Bell, Nicholas P

    2017-09-01

    To report long-term (>5 y) outcomes of plateau iris syndrome patients treated with argon laser peripheral iridoplasty (ALPI). A retrospective chart review was performed on all patients with plateau iris syndrome treated with ALPI from 1996 to 2007. The study included 22 eyes from 22 patients with plateau iris after peripheral iridotomy that were followed for at least 1 year after ALPI. The primary outcome was incidence of needing any intraocular pressure (IOP)-lowering medications or surgery (either a filtering procedure or phacoemulsification). Demographic and baseline clinical data were summarized by mean (±SD) or frequency (percentage). Snellen best-corrected visual acuity was converted to logMAR. The paired t test was used to compare IOP changes, number of IOP-lowering medications, and best-corrected visual acuity from baseline to annual follow-up. Mean follow-up was 76 months. Only 2 (9%) eyes maintained an IOPiris in our patient population.

  17. Management of complications of cosmetic iris implants in a phakic eye: a case report and literature review.

    Science.gov (United States)

    Bore, Millicent; Choudhari, Nikhil; Chaurasia, Sunita

    2018-03-21

    To report the intricacies of managing complications that arose out of cosmetic iris implants (BrightOcular) placement. Interventional case report. A thirty-year-old gentleman presented with complaint of progressive loss of vision after having cosmetic iris implant surgery to change his eye colour. He then developed raised intraocular pressures and had a right eye trabeculectomy conducted with the implants in situ. Subsequently, he had implant removal surgery because of persistent implant-associated complications. The vision was impaired due to progressive corneal oedema and glaucoma. Various considerations were taken while planning for surgical intervention because of the extensive structural damage to the anterior segment of the eye. This case report highlights that cosmetic iris implants are dangerous intraocular devices and management of the associated complications is also challenging. As these devices cause irreversible structural and functional damage, their use should be discouraged in normal eyes.

  18. Pigmentary Markers in Danes – Associations with Quantitative Skin Colour, Nevi Count, Familial Atypical Multiple-Mole, and Melanoma Syndrome

    DEFF Research Database (Denmark)

    Johansen, Peter; Andersen, Jeppe Dyrberg; Madsen, Linnea Nørgård

    2016-01-01

    pigmentation measured on the buttock area. We hypothesize that the effect of MC1R variants on arm pigmentation is primarily reflecting the inability to tan when subjected to UVR. A gender specific effect on skin pigmentation was also observed, and it was found that the skin pigmentation of females on average......To investigate whether pigmentation genes involved in the melanogenic pathway (melanogenesis) contributed to melanoma predisposition, we compared pigmentary genetics with quantitative skin pigmentation measurements, the number of atypical nevi, the total nevus count, and the familial atypical...... variants (missense, NM_002386:c. 456C > A (p.TYR152*), or NM_002386:c.83_84insA (p.Asn29Glnfs*14) had significantly (pskin pigmentation of the upper-inner arm than those with none or one MC1R variant. We did not observe any significant association of the MC1R variants with constitutive...

  19. Intraocular pressure elevation precedes a phagocytosis decline in a model of pigmentary glaucoma [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Yalong Dang

    2018-04-01

    Full Text Available Background: Outflow regulation and phagocytosis are key functions of the trabecular meshwork (TM, but it is not clear how the two are related in secondary open angle glaucomas characterized by an increased particle load. We hypothesized that diminished TM phagocytosis is not the primary cause of early ocular hypertension and recreated pigment dispersion in a porcine ex vivo model. Methods: Sixteen porcine anterior chamber cultures received a continuous infusion of pigment granules (Pg, while 16 additional anterior chambers served as controls (C. Pressure transducers recorded the intraocular pressure (IOP. The phagocytic capacity of the trabecular meshwork was determined by fluorescent microspheres. Results: The baseline IOPs in Pg and C were similar (P=0.82. A significant IOP elevation occurred in Pg at 48, 120, and 180 hours (all P0.05. Conclusions: In this porcine model of pigmentary glaucoma, an IOP elevation occurs much earlier than when phagocytosis fails, suggesting that two separate mechanisms might be at work.

  20. Pigmentary traits, family history of melanoma and the risk of endometriosis: a cohort study of US women.

    Science.gov (United States)

    Kvaskoff, Marina; Han, Jiali; Qureshi, Abrar A; Missmer, Stacey A

    2014-02-01

    Endometriosis has been associated with a higher risk of cutaneous melanoma, but the mechanisms underlying this association are unknown.Some constitutional factors known to influence melanoma risk have been associated with endometriosis in some retrospective studies. However, prospective data are scarce, and more research is needed to confirm this potentially novel endometriosis risk profile. To investigate the relationships between pigmentary traits, family history of melanoma and endometriosis risk, we analysed data from the Nurses’ Health Study II, a cohort of 116 430 female US nurses aged 25–42 years at inclusion in 1989. Data were collected every 2 years with 20 years of follow-up for these analyses. We used Cox proportional hazards regression models to compute relative risks(RRs) and 95% confidence intervals (CIs). During 1 212 499 woman-years of follow-up, 4763 cases of laparoscopically-confirmed endometriosis were reported among premenopausal Caucasian women. Endometriosis risk was increased with presence of naevi on the lower legs (RR=1.08, 95% CI=1.021.14) and higher level of skin’s burning reaction to sun exposure in childhood/adolescence (‘burn with blisters’: RR=1.20,95% CI=1.061.36) compared with ‘practically none’;P(trend)=0.0006) and family history of melanoma (RR=1.13, 95%CI=1.011.26). This assessment reports modest associations between several pigmentary traits, family history of melanoma and endometriosis risk,corroborating the results from previous retrospective studies. Our findings call for further research to better understand the mechanisms under lying these associations.

  1. Barumiki antocyjanowe u Iris germanica [Anthocyanin pigments in Iris germanica L.

    Directory of Open Access Journals (Sweden)

    J. Szczepańska

    2015-06-01

    Full Text Available Anthocyanin pigments occurring in the flowers of Iris germanica were investigated in five varieties: Rota, Wedgewood, Empress of India, Deputate Nomblot and Joanna. The relation between the colour of the flower and the amount of the pigment was studied. The pigments were extracted from the dry plant material with 1% hydrochloric acid in methanol. Paper chromatography and colorimetric determinations were used for identification of the pigments and their quantitative determination. The results allow the following conclusions: 1. The varieties investigated were characterized toy the occurrence of delphinidine glycoside; 2. The colour intensity is dependent on the anthocyanin pigments; 3. The colour spectrum of Iris sp. flowersis greatly extended by yellow copigments.

  2. 75 FR 76982 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2010-12-10

    ... Information System (IRIS); Announcement of Availability of Literature Searches for IRIS Assessments AGENCY: Environmental Protection Agency. ACTION: Announcement of availability of literature searches for IRIS... the availability of literature searches for four IRIS assessments, acetaldehyde (CAS No. 75-07-0...

  3. Iridium Interfacial Stack - IrIS

    Science.gov (United States)

    Spry, David

    2012-01-01

    Iridium Interfacial Stack (IrIS) is the sputter deposition of high-purity tantalum silicide (TaSi2-400 nm)/platinum (Pt-200 nm)/iridium (Ir-200 nm)/platinum (Pt-200 nm) in an ultra-high vacuum system followed by a 600 C anneal in nitrogen for 30 minutes. IrIS simultaneously acts as both a bond metal and a diffusion barrier. This bondable metallization that also acts as a diffusion barrier can prevent oxygen from air and gold from the wire-bond from infiltrating silicon carbide (SiC) monolithically integrated circuits (ICs) operating above 500 C in air for over 1,000 hours. This TaSi2/Pt/Ir/Pt metallization is easily bonded for electrical connection to off-chip circuitry and does not require extra anneals or masking steps. There are two ways that IrIS can be used in SiC ICs for applications above 500 C: it can be put directly on a SiC ohmic contact metal, such as Ti, or be used as a bond metal residing on top of an interconnect metal. For simplicity, only the use as a bond metal is discussed. The layer thickness ratio of TaSi2 to the first Pt layer deposited thereon should be 2:1. This will allow Si from the TaSi2 to react with the Pt to form Pt2Si during the 600 C anneal carried out after all layers have been deposited. The Ir layer does not readily form a silicide at 600 C, and thereby prevents the Si from migrating into the top-most Pt layer during future anneals and high-temperature IC operation. The second (i.e., top-most) deposited Pt layer needs to be about 200 nm to enable easy wire bonding. The thickness of 200 nm for Ir was chosen for initial experiments; further optimization of the Ir layer thickness may be possible via further experimentation. Ir itself is not easily wire-bonded because of its hardness and much higher melting point than Pt. Below the iridium layer, the TaSi2 and Pt react and form desired Pt2Si during the post-deposition anneal while above the iridium layer remains pure Pt as desired to facilitate easy and strong wire-bonding to the Si

  4. Scale Invariant Gabor Descriptor-Based Noncooperative Iris Recognition

    Directory of Open Access Journals (Sweden)

    Du Yingzi

    2010-01-01

    Full Text Available Abstract A new noncooperative iris recognition method is proposed. In this method, the iris features are extracted using a Gabor descriptor. The feature extraction and comparison are scale, deformation, rotation, and contrast-invariant. It works with off-angle and low-resolution iris images. The Gabor wavelet is incorporated with scale-invariant feature transformation (SIFT for feature extraction to better extract the iris features. Both the phase and magnitude of the Gabor wavelet outputs were used in a novel way for local feature point description. Two feature region maps were designed to locally and globally register the feature points and each subregion in the map is locally adjusted to the dilation/contraction/deformation. We also developed a video-based non-cooperative iris recognition system by integrating video-based non-cooperative segmentation, segmentation evaluation, and score fusion units. The proposed method shows good performance for frontal and off-angle iris matching. Video-based recognition methods can improve non-cooperative iris recognition accuracy.

  5. Scale Invariant Gabor Descriptor-based Noncooperative Iris Recognition

    Directory of Open Access Journals (Sweden)

    Zhi Zhou

    2010-01-01

    Full Text Available A new noncooperative iris recognition method is proposed. In this method, the iris features are extracted using a Gabor descriptor. The feature extraction and comparison are scale, deformation, rotation, and contrast-invariant. It works with off-angle and low-resolution iris images. The Gabor wavelet is incorporated with scale-invariant feature transformation (SIFT for feature extraction to better extract the iris features. Both the phase and magnitude of the Gabor wavelet outputs were used in a novel way for local feature point description. Two feature region maps were designed to locally and globally register the feature points and each subregion in the map is locally adjusted to the dilation/contraction/deformation. We also developed a video-based non-cooperative iris recognition system by integrating video-based non-cooperative segmentation, segmentation evaluation, and score fusion units. The proposed method shows good performance for frontal and off-angle iris matching. Video-based recognition methods can improve non-cooperative iris recognition accuracy.

  6. IRIS Toxicological Review of n-Butanol (Interagency Science ...

    Science.gov (United States)

    On September 8, 2011, the Toxicological Review of n-Butanol (External Review Draft) was released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process, introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments with EPA's response and the interagency science consultation draft of the IRIS Toxicological Review of n-Butanol and the charge to external peer reviewers are posted on this site. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for n-butanol. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  7. Evaluating the impact of image preprocessing on iris segmentation

    Directory of Open Access Journals (Sweden)

    José F. Valencia-Murillo

    2014-08-01

    Full Text Available Segmentation is one of the most important stages in iris recognition systems. In this paper, image preprocessing algorithms are applied in order to evaluate their impact on successful iris segmentation. The preprocessing algorithms are based on histogram adjustment, Gaussian filters and suppression of specular reflections in human eye images. The segmentation method introduced by Masek is applied on 199 images acquired under unconstrained conditions, belonging to the CASIA-irisV3 database, before and after applying the preprocessing algorithms. Then, the impact of image preprocessing algorithms on the percentage of successful iris segmentation is evaluated by means of a visual inspection of images in order to determine if circumferences of iris and pupil were detected correctly. An increase from 59% to 73% in percentage of successful iris segmentation is obtained with an algorithm that combine elimination of specular reflections, followed by the implementation of a Gaussian filter having a 5x5 kernel. The results highlight the importance of a preprocessing stage as a previous step in order to improve the performance during the edge detection and iris segmentation processes.

  8. Enhancement of Iris Recognition System Based on Phase Only Correlation

    Directory of Open Access Journals (Sweden)

    Nuriza Pramita

    2011-08-01

    Full Text Available Iris recognition system is one of biometric based recognition/identification systems. Numerous techniques have been implemented to achieve a good recognition rate, including the ones based on Phase Only Correlation (POC. Significant and higher correlation peaks suggest that the system recognizes iris images of the same subject (person, while lower and unsignificant peaks correspond to recognition of those of difference subjects. Current POC methods have not investigated minimum iris point that can be used to achieve higher correlation peaks. This paper proposed a method that used only one-fourth of full normalized iris size to achieve higher (or at least the same recognition rate. Simulation on CASIA version 1.0 iris image database showed that averaged recognition rate of the proposed method achieved 67%, higher than that of using one-half (56% and full (53% iris point. Furthermore, all (100% POC peak values of the proposed method was higher than that of the method with full iris points.

  9. Iris segmentation using an edge detector based on fuzzy sets theory and cellular learning automata.

    Science.gov (United States)

    Ghanizadeh, Afshin; Abarghouei, Amir Atapour; Sinaie, Saman; Saad, Puteh; Shamsuddin, Siti Mariyam

    2011-07-01

    Iris-based biometric systems identify individuals based on the characteristics of their iris, since they are proven to remain unique for a long time. An iris recognition system includes four phases, the most important of which is preprocessing in which the iris segmentation is performed. The accuracy of an iris biometric system critically depends on the segmentation system. In this paper, an iris segmentation system using edge detection techniques and Hough transforms is presented. The newly proposed edge detection system enhances the performance of the segmentation in a way that it performs much more efficiently than the other conventional iris segmentation methods.

  10. Trade off between variable and fixed size normalization in orthogonal polynomials based iris recognition system.

    Science.gov (United States)

    Krishnamoorthi, R; Anna Poorani, G

    2016-01-01

    Iris normalization is an important stage in any iris biometric, as it has a propensity to trim down the consequences of iris distortion. To indemnify the variation in size of the iris owing to the action of stretching or enlarging the pupil in iris acquisition process and camera to eyeball distance, two normalization schemes has been proposed in this work. In the first method, the iris region of interest is normalized by converting the iris into the variable size rectangular model in order to avoid the under samples near the limbus border. In the second method, the iris region of interest is normalized by converting the iris region into a fixed size rectangular model in order to avoid the dimensional discrepancies between the eye images. The performance of the proposed normalization methods is evaluated with orthogonal polynomials based iris recognition in terms of FAR, FRR, GAR, CRR and EER.

  11. IRIS: A SIGNIFICANT ELEMENT OF THE MEDITERRANEAN LANDSCAPE

    Directory of Open Access Journals (Sweden)

    A. UBRIZSY SAVOIA

    2000-01-01

    Full Text Available The Southern European species of Iris growing in dry, rocky places, stony ground, terra rossa, sandy, basalt and/or calcareous hills, maquis and coastal rocky slopes, are a neglected bioplasm resource of the Mediterranean landscape. These species have traditional uses and cultural significance and have inspired artists. Both natural and naturalised ornamental Iris species may help to improve and maintain the Mediterranean landscape by avoiding land erosion, fixing dunes and preserving coastal zones. These Iris species are a significant component of Mediterranean floristic diversity. Their conservation and use in traditional Mediterranean landscape gardening are emphasised.

  12. IRIS: A SIGNIFICANT ELEMENT OF THE MEDITERRANEAN LANDSCAPE

    Directory of Open Access Journals (Sweden)

    S. PIGNATTI

    2000-04-01

    Full Text Available The Southern European species of Iris growing in dry, rocky places, stony ground, terra rossa, sandy, basalt and/or calcareous hills, maquis and coastal rocky slopes, are a neglected bioplasm resource of the Mediterranean landscape. These species have traditional uses and cultural significance and have inspired artists. Both natural and naturalised ornamental Iris species may help to improve and maintain the Mediterranean landscape by avoiding land erosion, fixing dunes and preserving coastal zones. These Iris species are a significant component of Mediterranean floristic diversity. Their conservation and use in traditional Mediterranean landscape gardening are emphasised.

  13. Some measurement possibilities for the improvement of IRI

    International Nuclear Information System (INIS)

    Serafimov, K.B.

    1984-01-01

    Some methodological assumptions behind the development of improved measurements for use in the International Reference Ionosphere (IRI) are presented. Attention is given to improving the IRI-representation of electron density in the D-region by comparing data from vertical rocket soundings and absorption measurements on multifrequencies ionosondes; by the application of absorption measurements for the specification of density profile structure; and by the use of combined rocket and ground-based measurements. The methodological possibilities, for improving the IRI-distribution of electron densities in the bottomside and topside ionosphere, and for the specification of Te(h) profiles are also discussed

  14. Iris image enhancement for feature recognition and extraction

    CSIR Research Space (South Africa)

    Mabuza, GP

    2012-10-01

    Full Text Available the employment of other algorithms and commands so as to better present and demonstrate the obtained results. Edge detection and enhancing images for use in an iris recognition system allow for efficient recognition and extraction of iris patterns. REFERENCES... Gonzalez, R.C. and Woods, R.E. 2002. Digital Image Processing 2nd Edition, Instructor?s manual .Englewood Cliffs, Prentice Hall, pp 17-36. Proen?a, H. and Alexandre, L.A. 2007. Toward Noncooperative Iris Recognition: A classification approach using...

  15. BRCA1-IRIS Overexpression Promotes Formation of Aggressive Breast Cancers

    Science.gov (United States)

    Shimizu, Yoshiko; Luk, Hugh; Horio, David; Miron, Penelope; Griswold, Michael; Iglehart, Dirk; Hernandez, Brenda; Killeen, Jeffrey; ElShamy, Wael M.

    2012-01-01

    Introduction Women with HER2+ or triple negative/basal-like (TN/BL) breast cancers succumb to their cancer rapidly due, in part to acquired Herceptin resistance and lack of TN/BL-targeted therapies. BRCA1-IRIS is a recently discovered, 1399 residue, BRCA1 locus alternative product, which while sharing 1365 residues with the full-length product of this tumor suppressor gene, BRCA1/p220, it has oncoprotein-like properties. Here, we examine whether BRCA1-IRIS is a valuable treatment target for HER2+ and/or TN/BL tumors. Methodology/Principal Findings Immunohistochemical staining of large cohort of human breast tumor samples using new monoclonal anti-BRCA1-IRIS antibody, followed by correlation of BRCA1-IRIS expression with that of AKT1, AKT2, p-AKT, survivin and BRCA1/p220, tumor status and age at diagnosis. Generation of subcutaneous tumors in SCID mice using human mammary epithelial (HME) cells overexpressing TERT/LT/BRCA1-IRIS, followed by comparing AKT, survivin, and BRCA1/p220 expression, tumor status and aggressiveness in these tumors to that in tumors developed using TERT/LT/RasV12-overexpressing HME cells. Induction of primary and invasive rat mammary tumors using the carcinogen N-methyl-N-nitrosourea (NMU), followed by analysis of rat BRCA1-IRIS and ERα mRNA levels in these tumors. High BRCA1-IRIS expression was detected in the majority of human breast tumors analyzed, which was positively correlated with that of AKT1-, AKT2-, p-AKT-, survivin, but negatively with BRCA1/p220 expression. BRCA1-IRIS-positivity induced high-grade, early onset and metastatic HER2+ or TN/BL tumors. TERT/LT/BRCA1-IRIS overexpressing HME cells formed invasive subcutaneous tumors that express high AKT1, AKT2, p-AKT and vimentin, but no CK19, p63 or BRCA1/p220. NMU-induced primary and invasive rat breast cancers expressed high levels of rat BRCA1-IRIS mRNA but low levels of rat ERα mRNA. Conclusion/Significance BRCA1-IRIS overexpression triggers aggressive breast tumor formation

  16. Challenges at different stages of an iris based biometric system

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Singla

    2012-04-01

    Full Text Available Iris recognition has been used for authentication for the past few years and is capable of positive/negative authenticationof an individual without any physical contact or intervention. This technique is being used mainly because of its uniqueness,stability, and reliability but still many challenges are being faced an the iris based recognition system. This paperpresents the difficulties faced in different modules, like the sensor module, preprocessing module, feature extraction module,and matching module of an iris biometric system.

  17. Keskittymishäiriön kuvaaminen syanotypialla

    OpenAIRE

    Lammela, Maarit

    2017-01-01

    Toiminallisessa opinnäytetyössäni oli tavoitteena havainnollistaa kuvina luki- ja keskittymishäiriön tunnetiloja syanotypialla vedostaen. Projektissa tarkastelin ja tutkin itseäni. Havainnollistin kuvina yli viisikymmentä luonteenpiirrettä, jotka ovat tyypillisiä luki- ja keskittymishäiriöiselle ihmiselle. Näistä toteutin teoksiksi 25. Kuvasin itseäni ja tunnetilojani digikameralla itselaukaisinta apuna käyttäen. Halusin tehdä tämän työn kertoakseni luki- ja keskittymishäiriöisen ihmisen t...

  18. Iris's Functional Description using Zernike polynomials

    International Nuclear Information System (INIS)

    Munnoz, D. P.; Silva Mata, F. J.; Talavera, I.; Hernandez, N.; Augier, A.

    2012-01-01

    The main goal of this work is the texture representation of the iris original image by means of functional data. The essence of the method consists in obtaining an adjusted vector of coefficients by means of a least square approximation starting from the representation of the original image by the expansion on the two-dimensional Zernike basis. This type of representation provides remarkable advantages regarding other representations e.g. the appreciable reduction of the dimension of the data, the simplification of the general process of the image and those characteristics of the functional data analysis. The carried out experiments demonstrate the feasibility of this approach and they allowed determining the optimal dimension of the coefficients vectors by means of the minimization of the residual errors. To corroborate the effectiveness of this representation, some experiments on identification were carried out on international databases whose initial results are annexed in the work. (Author)

  19. Secondary Metabolites Isolated from Iris germanica

    Directory of Open Access Journals (Sweden)

    Muhammad I. Choudhary

    2009-06-01

    Full Text Available Phytochemical investigations of methanol extract of rhizome of Iris germanica L. resulted in the isolation of one new compound, 6,6-ditetradecyl-6,7-dihydrooxepin-2(3H-one (1 and five known compounds, 1-(2-(6′-hydroxy-2′-methylcyclohex-1′-enyloxy-5-methoxyphenylethanone (2 4-hydroxy-3-methoxyacetophenone (3, irisolone (4 irisolidone (5 and 2-acetoxy-3,6-dimethoxy-1,4-benzoquinone (6 .The structures of the compounds were determined on the basis of spectroscopic techniques. The antifungal activity of different soluble portions was measured. The hexane soluble portion of the methanol extract showed significant antifungal activity where as the ethyl acetate and chloroform soluble portions showed moderate activity. The methanol extract showed no antifungal activity.

  20. Iris Data Classification Using Quantum Neural Networks

    International Nuclear Information System (INIS)

    Sahni, Vishal; Patvardhan, C.

    2006-01-01

    Quantum computing is a novel paradigm that promises to be the future of computing. The performance of quantum algorithms has proved to be stunning. ANN within the context of classical computation has been used for approximation and classification tasks with some success. This paper presents an idea of quantum neural networks along with the training algorithm and its convergence property. It synergizes the unique properties of quantum bits or qubits with the various techniques in vogue in neural networks. An example application of Fisher's Iris data set, a benchmark classification problem has also been presented. The results obtained amply demonstrate the classification capabilities of the quantum neuron and give an idea of their promising capabilities

  1. Degradation monitoring in IRIS steam generators

    International Nuclear Information System (INIS)

    Alpay, B.; Holloway, J. P.; Lee, J. C.

    2007-01-01

    We present a degradation monitoring technique based on unscented Kalman filtering (UKF), which uses a nonlinear system model without linearization to estimate the status of the component/state variables. To test the applicability of the methodology, the fouling of tubes is chosen among various degradation mechanisms for the IRIS (International Reactor Innovative and Secure) steam generators (SGs). The degradation monitoring algorithm diagnoses the tube fouling and estimates the thickness of the crud deposited on the secondary side of the SG along with the increase in the pressure drop triggered by fouling. A stand-alone SG model developed with the RELAP5 code was used to simulate the transient behavior of the SG and drive an UKF state estimate. By using the secondary side outlet temperature as the measurement and the nodal pressures along the secondary side as states, UKF generated accurate estimates of the crud layer thicknesses for different crud formations. (authors)

  2. Regression Patterns of Iris Melanoma after Palladium-103 (103Pd) Plaque Brachytherapy.

    Science.gov (United States)

    Chaugule, Sonal S; Finger, Paul T

    2017-07-01

    To evaluate the patterns of regression of iris melanoma after treatment with palladium-103 ( 103 Pd) plaque brachytherapy. Retrospective, nonrandomized, interventional case series. Fifty patients with primary malignant melanoma of the iris. Palladium-103 plaque brachytherapy. Changes in tumor size, pigmentation, and vascularity; incidence of iris neovascularization; and radiation-related complications. The mean age in the case series was 61.2±14.9 years. The mean tumor thickness was 1.4±0.6 mm. According to the American Joint Committee on Cancer, eighth edition, staging criteria for iris melanoma, 21 tumors (42%) were T1a, 5 tumors (10%) were T1b, and 24 tumors (48%) were T2a. The tumor was melanotic in 37 cases (74%) and amelanotic in 13 cases (26%); of these, 13 tumors (26%) showed variable pigmentation. After brachytherapy, mean tumor thickness decreased to 0.9±0.2 mm. Pigmentation increased in 32 tumors (64%), decreased in 11 tumors (22%), and was unchanged in 6 tumors (12%). For intrinsic vascularity (n = 19), 12 tumors (63%) showed decrease and 7 tumors (37%) showed complete resolution. Appearance of ectropion uveae showed diminution in 15 tumors (43%); newly present corectopia was observed in 6 patients (12%). On high-frequency ultrasound imaging, of the 42 tumors (84%) with low to moderate internal reflectivity, 30 tumors (60%) showed an increase in internal reflectivity on regression. Iris stromal atrophy was noted in 26 patients (52%), progression or new-onset cataract was noted in 22 patients (44%), neovascular glaucoma was noted in 1 patient (2%), and there were no cases of corneal opacity. There was no clinical evidence (0%) of radiation-induced retinopathy, maculopathy, or optic neuropathy. Mean follow-up in this series was 5.2 years (range, 0.5-17 years). The most common findings related to iris melanoma regression after 103 Pd plaque brachytherapy included decreased intrinsic tumor vascularity, increased tumor pigmentation, and decreased tumor

  3. Dynamic modeling of primary and secondary systems of IRIS reactor for transient analysis using SIMULINK

    International Nuclear Information System (INIS)

    Magalhaes, Mardson Alencar de Sa; Lira, Carlos Alberto Brayner de Oliveira; Silva, Mario Augusto Bezerra da

    2011-01-01

    The IRIS project has significantly advanced in the last few years in response to a demand for a new generation reactor, that could fulfill the essential requirements for a future nuclear power plant: better economics, safety-by-design, low proliferation risk and environmental sustainability. IRIS reactor is a integral type PWR in which all primary components are arranged inside the pressure vessel. This configuration involves important changes in relation to a conventional PWR. These changes require several studies to comply with the safe operational limits for the reactor. In this paper, a study has been conducted to develop a dynamic model (named MODIRIS) for transient analysis, implemented in the MATLAB'S software SIMULINK, allowing the analysis of IRIS behavior by considering the neutron point kinetics for power production. The methodology is based on generating a set of differential equations of neutronic and thermal-hydraulic balances which describes the dynamics of the primary circuit, as well as a set of differential equations describing the dynamics of secondary circuit. The equations and initialization parameters at full power were into the SIMULINK and the code was validated by the confrontation with RELAP simulations for a transient of feedwater reduction in the steam generators. (author)

  4. Establishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography.

    Directory of Open Access Journals (Sweden)

    Jeffrey R Peterson

    Full Text Available Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT.Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years. ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL, length of scleral spur landmark (SSL to pupillary margin (SSL-to-PM, iris contour ratio (ICR = AISL/SSL-to-PM, pupil radius, radius of iris centroid (RICe, and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter.Mean (±SD values were 2.24 mm (±0.46, 4.06 mm (±0.27, 3.65 mm (±0.48, 4.16 mm (±0.47, 1.14 (±0.04, 1.51 mm2 (±0.23, and 38.42 μL (±4.91 for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002 and RICe (P = 0.027 decreased with age, while SSL-to-PM (P = 0.002 and AISL increased with age (P = 0.001. ICR (P = 0.54 and iris volume (P = 0.49 were not affected by age.This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.

  5. Facilitate, Collaborate, Educate: the Role of the IRIS Consortium in Supporting National and International Research in Seismology (Invited)

    Science.gov (United States)

    Simpson, D. W.; Beck, S. L.

    2009-12-01

    Over the twenty-five years since its founding in 1984, the IRIS Consortium has contributed in fundamental ways to change the practice and culture of research in seismology in the US and worldwide. From an original founding group of twenty-two U.S. academic institutions, IRIS membership has now grown to 114 U.S. Member Institutions, 20 Educational Affiliates and 103 Foreign Affiliates. With strong support from the National Science Foundation, additional resources provided by other federal agencies, close collaboration with the U.S. Geological Survey and many international partners, the technical resources of the core IRIS programs - the Global Seismographic Network (GSN), the Program for Array Seismic Studies of the Continental Lithosphere (PASSCAL), the Data Management System (DMS) and Education and Outreach - have grown to become a major national and international source of experimental data for research on earthquakes and Earth structure, and a resource to support education and outreach to the public. While the primary operational focus of the Consortium is to develop and maintain facilities for the collection of seismological data for basic research, IRIS has become much more than an instrument facility. It has become a stimulus for collaboration between academic seismological programs and a focus for their interactions with national and international partners. It has helped establish the academic community as a significant contributor to the collection of data and an active participant in global research and monitoring. As a consortium of virtually all of the Earth science research institutions in the US, IRIS has helped coordinate the academic community in the development of new initiatives, such as EarthScope, to strengthen the support for science and argue for the relevance of seismology and its use in hazard mitigation. The early IRIS pioneers had the foresight to carefully define program goals and technical standards for the IRIS facilities that have stood

  6. Peer Review Comments on the IRIS Assessment of Benzene

    Science.gov (United States)

    Attachment to IRIS file for benzene, January 19, 2000, RESPONSE TO THE PEER REVIEW COMMENTS, II. Extrapolation of the Benzene Inhalation Unit Risk Estimate to the Oral Route of Exposure (EPA/NCEA-W-0517, July 1999)

  7. IRIS Toxicological Review of Hexavalent Chromium (Peer Review Plan)

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of hexavalent chromium that will appear on the Integrated Risk Information System (IRIS) database.

  8. an enhanced iris recognition and authentication system using ...

    African Journals Online (AJOL)

    Biu et al.

    1Department of Mathematical Sciences, Kaduna State University, Kaduna – Nigeria. (E-mail: ..... localization, the iris is in a circulation fashion then lastly, the image is saved into .... Conference on Computer Engineering Systems. Cleve, K.

  9. IRIS Toxicological Review of Trichloroacetic Acid (TCA) (External Review Draft)

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroacetic acid (TCA) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  10. IRIS Toxicological Review of Trichloroacetic Acid (Tca) (Final Report)

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Trichloroacetic Acid: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  11. IRIS Toxicological Review of Trichloroethylene (Interagency Science Discussion Draft)

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review of Trichloroethylene, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies ...

  12. IRIS Toxicological Review of Trichloroethylene (TCE) (External Review Draft)

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroethylene (TCE) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  13. IRIS Toxicological Review of Hydrogen Cyanide (External Review Draft)

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of hydrogen cyanide and cyanide salts that will appear on the Integrated Risk Information System (IRIS) database.

  14. Bilateral acute iris transillumination (BAIT initially misdiagnosed as acute iridocyclitis

    Directory of Open Access Journals (Sweden)

    Saban Gonul

    2015-04-01

    Full Text Available Bilateral acute iris transillumination (BAIT is a relatively new clinical entity characterized by bilateral acute loss of iris pigment epithelium, iris transillumination, pigment dispersion in the anterior chamber, and sphincter paralysis. We report the case of a 30-year-old male who was initially diagnosed with acute iridocyclitis in a different clinic and treated with topical and systemic corticosteroids. He was referred to our clinic to seek another opinion because his symptoms did not improve. An ocular examination revealed bilateral pigment dispersion into the anterior chamber, diffuse iris transillumination, pigment dusting on the anterior lens capsule, atonic and distorted pupils, and increased intraocular pressure, suggesting a diagnosis of BAIT rather than iridocyclitis. Clinicians should be aware of the differential diagnosis of syndromes associated with pigment dispersion from iridocyclitis to avoid aggressive anti-inflammatory therapy and detailed investigation for uveitis.

  15. IRIS Toxicological Review of Tetrahydrofuran (THF) (External Review Draft)

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of tetrahydrofuran (THF) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  16. IRIS Toxicological Review of Methanol (Noncancer) (Final Report)

    Science.gov (United States)

    EPA conducted a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Methanol (noncancer) , this is finalized and posted on the IRIS Web site.

  17. IRIS Toxicological Review of Tetrahydrofuran (THF) (Final Report)

    Science.gov (United States)

    EPA has released the Toxicological Review of Tetrahydrofuran: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  18. Iris recognition using possibilistic fuzzy matching on local features.

    Science.gov (United States)

    Tsai, Chung-Chih; Lin, Heng-Yi; Taur, Jinshiuh; Tao, Chin-Wang

    2012-02-01

    In this paper, we propose a novel possibilistic fuzzy matching strategy with invariant properties, which can provide a robust and effective matching scheme for two sets of iris feature points. In addition, the nonlinear normalization model is adopted to provide more accurate position before matching. Moreover, an effective iris segmentation method is proposed to refine the detected inner and outer boundaries to smooth curves. For feature extraction, the Gabor filters are adopted to detect the local feature points from the segmented iris image in the Cartesian coordinate system and to generate a rotation-invariant descriptor for each detected point. After that, the proposed matching algorithm is used to compute a similarity score for two sets of feature points from a pair of iris images. The experimental results show that the performance of our system is better than those of the systems based on the local features and is comparable to those of the typical systems.

  19. Iris recognition based on robust principal component analysis

    Science.gov (United States)

    Karn, Pradeep; He, Xiao Hai; Yang, Shuai; Wu, Xiao Hong

    2014-11-01

    Iris images acquired under different conditions often suffer from blur, occlusion due to eyelids and eyelashes, specular reflection, and other artifacts. Existing iris recognition systems do not perform well on these types of images. To overcome these problems, we propose an iris recognition method based on robust principal component analysis. The proposed method decomposes all training images into a low-rank matrix and a sparse error matrix, where the low-rank matrix is used for feature extraction. The sparsity concentration index approach is then applied to validate the recognition result. Experimental results using CASIA V4 and IIT Delhi V1iris image databases showed that the proposed method achieved competitive performances in both recognition accuracy and computational efficiency.

  20. Embedded Design Research of Iris Information Acquisition System

    Directory of Open Access Journals (Sweden)

    Huiyan Xu

    2014-09-01

    Full Text Available In view of the limitation of traditional identification, it is easy to lose and copy keys, cards or ID cards, and it is easy to forget the password, so we designed an embedded application system based on the iris identification technology, which can realize the functions of gathering, inputting, and registering the iris information and identification. The hardware circuit was designed by using advanced RISC machines (ARM embedded microprocessor as the core. The iris sensor was used to gather the iris information, and the development of software was accomplished with the embedded OS Windows CE. The system can be used on the company entrance guard system, customs security of airport and criminal identification.

  1. A bibliography of IRIS-related publications, 2000-2011

    Science.gov (United States)

    Muco, B.

    2012-12-01

    Citations and acknowledgements in scientific journals can be an indicator of the role an organization has on the research of that field. Since its formation and incorporation in May 1984, the IRIS Consortium (Incorporated Research Institutions for Seismology) is mentioned more and more as a valuable source of data, instruments and programs in the literature of earth sciences. As a large organization with more than 100 member domestic institutes and about 40 international affiliates, obviously IRIS has a direct impact on the earth sciences through all its programs, projects, workshops, symposia, and news¬letters and as a lively forum for exchanging ideas. In order to maintain support from National Science Foundation (NSF) and the research community, it is important to document the continued use of IRIS facilities in basic research programs. IRIS maintains a database of articles that are based on the use of IRIS facilities or which reference use of IRIS data and resources. Articles in this database have been either been provided to IRIS by the authors or selected through an annual search of a number of prominent journals. A text version of the full bibliographic database is available on the IRIS website and a version in EndNote format is also provided. To provide a more complete bibliography and a consistent evaluation of temporal tends in publications, a special annual search began in 2000 which focused on a subset of key seismology and Earth science journals: Bulletin of Seismological Society of America, Journal of Geophysical Research, Seismological Research Letters, Geophysical Research Letters, Earth and Planetary Science Letters, Physics of the Earth and Planetary Interiors, Tectonophysics, Geophysical Journal International, Nature, Science, Geology and EOS. Using different search engines as Scirus, ScienceDirect, GeoRef, OCLC First Search, EASI Search, NASA Abstract Service etc. for online journals and publishers' databases, we searched for key words (IRIS

  2. IRIS: A SIGNIFICANT ELEMENT OF THE MEDITERRANEAN LANDSCAPE

    OpenAIRE

    A. UBRIZSY SAVOIA; S. PIGNATTI; S. VAROLI PIAZZA

    2000-01-01

    The Southern European species of Iris growing in dry, rocky places, stony ground, terra rossa, sandy, basalt and/or calcareous hills, maquis and coastal rocky slopes, are a neglected bioplasm resource of the Mediterranean landscape. These species have traditional uses and cultural significance and have inspired artists. Both natural and naturalised ornamental Iris species may help to improve and maintain the Mediterranean landscape by avoiding land erosion, fixing dunes and preserving coastal...

  3. IRIS: A global approach to nuclear power renaissance

    International Nuclear Information System (INIS)

    Carelli, M.D.

    2004-01-01

    Improved international reactor IRIS (International Reactor Innovative and Secure) is discussed. IRIS is defined as a modular reactor with integral arrangement and water coolant. Design of reactor core and fuel elements is considered. Use of radial neutron reflectors from stainless steel is favorable to decrease of cost and increase of reactor operation. Reactor maintenance, constructional safety and arrangement of plant are characterized. Economical analysis and marketing are performed [ru

  4. Antigen-Specific Interferon-Gamma Responses and Innate Cytokine Balance in TB-IRIS

    Science.gov (United States)

    Goovaerts, Odin; Jennes, Wim; Massinga-Loembé, Marguerite; Ceulemans, Ann; Worodria, William; Mayanja-Kizza, Harriet; Colebunders, Robert; Kestens, Luc

    2014-01-01

    Background Tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) remains a poorly understood complication in HIV-TB patients receiving antiretroviral therapy (ART). TB-IRIS could be associated with an exaggerated immune response to TB-antigens. We compared the recovery of IFNγ responses to recall and TB-antigens and explored in vitro innate cytokine production in TB-IRIS patients. Methods In a prospective cohort study of HIV-TB co-infected patients treated for TB before ART initiation, we compared 18 patients who developed TB-IRIS with 18 non-IRIS controls matched for age, sex and CD4 count. We analyzed IFNγ ELISpot responses to CMV, influenza, TB and LPS before ART and during TB-IRIS. CMV and LPS stimulated ELISpot supernatants were subsequently evaluated for production of IL-12p70, IL-6, TNFα and IL-10 by Luminex. Results Before ART, all responses were similar between TB-IRIS patients and non-IRIS controls. During TB-IRIS, IFNγ responses to TB and influenza antigens were comparable between TB-IRIS patients and non-IRIS controls, but responses to CMV and LPS remained significantly lower in TB-IRIS patients. Production of innate cytokines was similar between TB-IRIS patients and non-IRIS controls. However, upon LPS stimulation, IL-6/IL-10 and TNFα/IL-10 ratios were increased in TB-IRIS patients compared to non-IRIS controls. Conclusion TB-IRIS patients did not display excessive IFNγ responses to TB-antigens. In contrast, the reconstitution of CMV and LPS responses was delayed in the TB-IRIS group. For LPS, this was linked with a pro-inflammatory shift in the innate cytokine balance. These data are in support of a prominent role of the innate immune system in TB-IRIS. PMID:25415590

  5. International Roughness Index (IRI) measurement using Hilbert-Huang transform

    Science.gov (United States)

    Zhang, Wenjin; Wang, Ming L.

    2018-03-01

    International Roughness Index (IRI) is an important metric to measure condition of roadways. This index is usually used to justify the maintenance priority and scheduling for roadways. Various inspection methods and algorithms are used to assess this index through the use of road profiles. This study proposes to calculate IRI values using Hilbert-Huang Transform (HHT) algorithm. In particular, road profile data is provided using surface radar attached to a vehicle driving at highway speed. Hilbert-Huang transform (HHT) is used in this study because of its superior properties for nonstationary and nonlinear data. Empirical mode decomposition (EMD) processes the raw data into a set of intrinsic mode functions (IMFs), representing various dominating frequencies. These various frequencies represent noises from the body of the vehicle, sensor location, and the excitation induced by nature frequency of the vehicle, etc. IRI calculation can be achieved by eliminating noises that are not associated with the road profile including vehicle inertia effect. The resulting IRI values are compared favorably to the field IRI values, where the filtered IMFs captures the most characteristics of road profile while eliminating noises from the vehicle and the vehicle inertia effect. Therefore, HHT is an effect method for road profile analysis and for IRI measurement. Furthermore, the application of HHT method has the potential to eliminate the use of accelerometers attached to the vehicle as part of the displacement measurement used to offset the inertia effect.

  6. Analysis of iris surface features in populations of diverse ancestry

    Science.gov (United States)

    Edwards, Melissa; Cha, David; Krithika, S.; Johnson, Monique; Parra, Esteban J.

    2016-01-01

    There are many textural elements that can be found in the human eye, including Fuchs’ crypts, Wolfflin nodules, pigment spots, contraction furrows and conjunctival melanosis. Although iris surface features have been well-studied in populations of European ancestry, the worldwide distribution of these traits is poorly understood. In this paper, we develop a new method of characterizing iris features from photographs of the iris. We then apply this method to a diverse sample of East Asian, European and South Asian ancestry. All five iris features showed significant differences in frequency between the three populations, indicating that iris features are largely population dependent. Although none of the features were correlated with each other in the East and South Asian groups, Fuchs’ crypts were significantly correlated with contraction furrows and pigment spots and contraction furrows were significantly associated with pigment spots in the European group. The genetic marker SEMA3A rs10235789 was significantly associated with Fuchs’ crypt grade in the European, East Asian and South Asian samples and a borderline association between TRAF3IP1 rs3739070 and contraction furrow grade was found in the European sample. The study of iris surface features in diverse populations may provide valuable information of forensic, biomedical and ophthalmological interest. PMID:26909168

  7. Cosmetic Detection Framework for Face and Iris Biometrics

    Directory of Open Access Journals (Sweden)

    Omid Sharifi

    2018-04-01

    Full Text Available Cosmetics pose challenges to the recognition performance of face and iris biometric systems due to its ability to alter natural facial and iris patterns. Facial makeup and iris contact lens are considered to be commonly applied cosmetics for the face and iris in this study. The present work aims to present a novel solution for the detection of cosmetics in both face and iris biometrics by the fusion of texture, shape and color descriptors of images. The proposed cosmetic detection scheme combines the microtexton information from the local primitives of texture descriptors with the color spaces achieved from overlapped blocks in order to achieve better detection of spots, flat areas, edges, edge ends, curves, appearance and colors. The proposed cosmetic detection scheme was applied to the YMU YouTube makeup database (YMD facial makeup database and IIIT-Delhi Contact Lens iris database. The results demonstrate that the proposed cosmetic detection scheme is significantly improved compared to the other schemes implemented in this study.

  8. SINGLE FRAME SUPER RESOLUTION OF NONCOOPERATIVE IRIS IMAGES

    Directory of Open Access Journals (Sweden)

    Anand Deshpande

    2016-11-01

    Full Text Available Image super-resolution, a process to enhance image resolution, has important applications in biometrics, satellite imaging, high definition television, medical imaging, etc. The long range captured iris identification systems often suffer from low resolution and meager focus of the captured iris images. These degrade the iris recognition performance. This paper proposes enhanced iterated back projection (EIBP method to super resolute the long range captured iris polar images. The performance of proposed method is tested and analyzed on CASIA long range iris database by comparing peak signal to noise ratio (PSNR and structural similarity index (SSIM with state-of-the-art super resolution (SR algorithms. It is further analyzed by increasing the up-sampling factor. Performance analysis shows that the proposed method is superior to state-of-the-art algorithms, the peak signal-to-noise ratio improved about 0.1-1.5 dB. The results demonstrate that the proposed method is well suited to super resolve the iris polar images captured at a long distance

  9. Towards online iris and periocular recognition under relaxed imaging constraints.

    Science.gov (United States)

    Tan, Chun-Wei; Kumar, Ajay

    2013-10-01

    Online iris recognition using distantly acquired images in a less imaging constrained environment requires the development of a efficient iris segmentation approach and recognition strategy that can exploit multiple features available for the potential identification. This paper presents an effective solution toward addressing such a problem. The developed iris segmentation approach exploits a random walker algorithm to efficiently estimate coarsely segmented iris images. These coarsely segmented iris images are postprocessed using a sequence of operations that can effectively improve the segmentation accuracy. The robustness of the proposed iris segmentation approach is ascertained by providing comparison with other state-of-the-art algorithms using publicly available UBIRIS.v2, FRGC, and CASIA.v4-distance databases. Our experimental results achieve improvement of 9.5%, 4.3%, and 25.7% in the average segmentation accuracy, respectively, for the UBIRIS.v2, FRGC, and CASIA.v4-distance databases, as compared with most competing approaches. We also exploit the simultaneously extracted periocular features to achieve significant performance improvement. The joint segmentation and combination strategy suggest promising results and achieve average improvement of 132.3%, 7.45%, and 17.5% in the recognition performance, respectively, from the UBIRIS.v2, FRGC, and CASIA.v4-distance databases, as compared with the related competing approaches.

  10. A multi-approach feature extractions for iris recognition

    Science.gov (United States)

    Sanpachai, H.; Settapong, M.

    2014-04-01

    Biometrics is a promising technique that is used to identify individual traits and characteristics. Iris recognition is one of the most reliable biometric methods. As iris texture and color is fully developed within a year of birth, it remains unchanged throughout a person's life. Contrary to fingerprint, which can be altered due to several aspects including accidental damage, dry or oily skin and dust. Although iris recognition has been studied for more than a decade, there are limited commercial products available due to its arduous requirement such as camera resolution, hardware size, expensive equipment and computational complexity. However, at the present time, technology has overcome these obstacles. Iris recognition can be done through several sequential steps which include pre-processing, features extractions, post-processing, and matching stage. In this paper, we adopted the directional high-low pass filter for feature extraction. A box-counting fractal dimension and Iris code have been proposed as feature representations. Our approach has been tested on CASIA Iris Image database and the results are considered successful.

  11. Use of epidemiologic data in Integrated Risk Information System (IRIS) assessments

    International Nuclear Information System (INIS)

    Persad, Amanda S.; Cooper, Glinda S.

    2008-01-01

    In human health risk assessment, information from epidemiologic studies is typically utilized in the hazard identification step of the risk assessment paradigm. However, in the assessment of many chemicals by the Integrated Risk Information System (IRIS), epidemiologic data, both observational and experimental, have also been used in the derivation of toxicological risk estimates (i.e., reference doses [RfD], reference concentrations [RfC], oral cancer slope factors [CSF] and inhalation unit risks [IUR]). Of the 545 health assessments posted on the IRIS database as of June 2007, 44 assessments derived non-cancer or cancer risk estimates based on human data. RfD and RfC calculations were based on a spectrum of endpoints from changes in enzyme activity to specific neurological or dermal effects. There are 12 assessments with IURs based on human data, two assessments that extrapolated human inhalation data to derive CSFs and one that used human data to directly derive a CSF. Lung or respiratory cancer is the most common endpoint for cancer assessments based on human data. To date, only one chemical, benzene, has utilized human data for derivation of all three quantitative risk estimates (i.e., RfC, RfD, and dose-response modeling for cancer assessment). Through examples from the IRIS database, this paper will demonstrate how epidemiologic data have been used in IRIS assessments for both adding to the body of evidence in the hazard identification process and in the quantification of risk estimates in the dose-response component of the risk assessment paradigm

  12. Lessons learned from IRIS EPO program evaluations

    Science.gov (United States)

    Taber, J.; Hubenthal, M.

    2012-12-01

    Evaluating the overall impact of EPO programs that include activities ranging from formal education through broad public outreach, is a complex issue. The impact of education activities targeted at narrowly defined audiences is generally easier to quantify than the national impact of outreach activities conducted by a relatively small program. For educational activities, our approach has been to leverage the best-practices identified through research and to continuously assess the individual elements internally with the intention of making improvements based on the data generated and the existing research. By constructing our elements on the best practices identified by the research community we feel that internal formative evaluation is a valid means to determine if an activity is effective, particularly when the results are compared to similar programs. For example, effective practices of professional development are well documented in the literature. As a result, this allows us to shape our programs and our evaluations to monitor elements that have been identified as key by the educational research community. Further, such actions allow us to avoid allocating significant resources with the intention of pinning down direct causal relationships between our programs and consumers, when similar interventions (conducted by others) have already shown such relationships. Ongoing review by an EPO advisory committee also provides regular oversight of program impact. While we find internal and external formative evaluation extremely useful in shaping the program and documenting its impact, we also recognize the value of a summative evaluation process. For example, an external summative evaluation of the IRIS EPO program was conducted in 2009, followed by an external panel review, as part of the regular review of IRIS programs. We found that the most valuable part of the external evaluation was our preparation, including clarifying the goals of each of the elements of the

  13. Anterior Segment Optical Coherence Tomography Angiography for Identification of Iris Vasculature and Staging of Iris Neovascularization: A Pilot Study.

    Science.gov (United States)

    Roberts, Philipp K; Goldstein, Debra A; Fawzi, Amani A

    2017-08-01

    Purpose/Aim of the study: To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the "eyes at risk" group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI.

  14. The fast iris image clarity evaluation based on Tenengrad and ROI selection

    Science.gov (United States)

    Gao, Shuqin; Han, Min; Cheng, Xu

    2018-04-01

    In iris recognition system, the clarity of iris image is an important factor that influences recognition effect. In the process of recognition, the blurred image may possibly be rejected by the automatic iris recognition system, which will lead to the failure of identification. Therefore it is necessary to evaluate the iris image definition before recognition. Considered the existing evaluation methods on iris image definition, we proposed a fast algorithm to evaluate the definition of iris image in this paper. In our algorithm, firstly ROI (Region of Interest) is extracted based on the reference point which is determined by using the feature of the light spots within the pupil, then Tenengrad operator is used to evaluate the iris image's definition. Experiment results show that, the iris image definition algorithm proposed in this paper could accurately distinguish the iris images of different clarity, and the algorithm has the merit of low computational complexity and more effectiveness.

  15. An effective approach for iris recognition using phase-based image matching.

    Science.gov (United States)

    Miyazawa, Kazuyuki; Ito, Koichi; Aoki, Takafumi; Kobayashi, Koji; Nakajima, Hiroshi

    2008-10-01

    This paper presents an efficient algorithm for iris recognition using phase-based image matching--an image matching technique using phase components in 2D Discrete Fourier Transforms (DFTs) of given images. Experimental evaluation using CASIA iris image databases (versions 1.0 and 2.0) and Iris Challenge Evaluation (ICE) 2005 database clearly demonstrates that the use of phase components of iris images makes possible to achieve highly accurate iris recognition with a simple matching algorithm. This paper also discusses major implementation issues of our algorithm. In order to reduce the size of iris data and to prevent the visibility of iris images, we introduce the idea of 2D Fourier Phase Code (FPC) for representing iris information. The 2D FPC is particularly useful for implementing compact iris recognition devices using state-of-the-art Digital Signal Processing (DSP) technology.

  16. Iris small break loca phenomena identification and ranking table (PIRT)

    International Nuclear Information System (INIS)

    Larson, T.K.; Moody, F.J.; Wilson, G.E.; Brown, W.L.; Frepoli, C.; Hartz, J.; Woods, B.G.; Oriani, L.

    2007-01-01

    The international reactor innovative and secure (IRIS) is a modular pressurized water reactor with an integral configuration (all primary system components - reactor core, internals, pumps, steam generators, pressurizer, and control rod drive mechanisms - are inside the reactor vessel). The IRIS plant conceptual design was completed in 2001 and the preliminary design is currently underway. The pre-application licensing process with the United States Nuclear Regulatory Commission (USNRC) started in October 2002. The first line of defense in IRIS is to eliminate event initiators that could potentially lead to core damage. If it is not possible to eliminate certain accidents altogether, then the design inherently reduces their consequences and/or decreases their probability of occurring. One of the most obvious advantages of the IRIS Safety-by-Design TM approach is the elimination of large break loss-of-coolant accidents (LBLOCAs), since no large primary penetrations of the reactor vessel or large loop piping exist. While the IRIS Safety-by-Design TM approach is a logical step in the effort to produce advanced reactors, the desired advances in safety must still be demonstrated in the licensing arena. With the elimination of LBLOCA, an important next consideration is to show the IRIS design fulfills the promise of increased safety also for small break LOCAs (SBLOCAs). Accordingly, the SBLOCA phenomena identification and ranking table (PIRT) project was established. The primary objective of the IRIS SBLOCA PIRT project was to identify the relative importance of phenomena in the IRIS response to SBLOCAs. This relative importance, coupled with the current relative state of knowledge for the phenomena, provides a framework for the planning of the continued experimental and analytical efforts. To satisfy the SBLOCA PIRT project objectives, Westinghouse organized an expert panel whose members were carefully selected to insure that the PIRT results reflect internationally

  17. Under the hood of IRIS's Distributed REU Site

    Science.gov (United States)

    Hubenthal, M.; Taber, J.

    2014-12-01

    Since 1998 the IRIS Undergraduate Internship Program has provided research experiences for up to 15 students each summer. Through this 9 to 11 week internship program, students take part in an intensive week-long preparatory course, and work with leaders in seismological research, in both lab-base and field-based settings, to produce research products worthy of presentation and recognition at large professional conferences. The IRIS internship program employs a distributed REU model that has been demonstrated to bond students into a cohort, and maintain group cohesion despite students conducting their research at geographically distributed sites. Over the past 16 years the program has encountered numerous anticipated and unanticipated challenges. The primary challenges have involved exploring how to modify the REU-system to produce outcomes that are better aligned with our programmatic goals. For example, some questions we have attempted to address include: How can the success of an REU site be measured? How do you find, interest, and recruit under-represented minorities into a geophysics program? Can the program increase the probability of interns receiving some minimal level of mentoring across the program? While it is likely that no single answer to these questions exists, we have developed and piloted a number of strategies. These approaches have been developed through a process of identifying relevant research results from other REUs and combing this information with data from our own programmatic evaluations. This data informs the development of specific changes within our program which are then measured as a feedback. We will present our current strategies to address each questions along with measures of their effectiveness. In addition to broad scale systematic issues, we have also placed significant effort into responding to smaller, process challenges that all REU sites face. These range from simple logistical issues (e.g. liability), to educational

  18. Immune Reconstitution Inflammatory Syndrome (IRIS): What pathologists should know.

    Science.gov (United States)

    Nelson, Ann Marie; Manabe, Yukari C; Lucas, Sebastian B

    2017-07-01

    Antiretroviral therapy has significantly improved the quality and length of life for those patients able to access effective and sustained treatment. The resulting restoration of the immune response is associated with a change in the clinical presentation of opportunistic infections, and the histologic reaction to pathogens. A complex combination of alterations in host response across the stages of HIV infection has been documented over the past 3 decades. The defects are seen in both acute and chronic phases of inflammation and involve innate and adaptive immunity. In advanced stages of HIV infection, the marked disruption of lymphoid tissue and loss of follicular dendritic cells limits the host's ability to process antigen and mount specific responses to pathogens. There are qualitative and quantitative defects in CD4 T cells due to HIV infection. The resulting indirect effects include loss of cytokine production, dysregulation of B-cell function, loss of cellular mediated immunity and "holes" in the immunologic repertoire that may not be restored with the use of antiretroviral therapy. Immune reconstitution allows the host to respond to and control infection, but a significant number of patients will have atypical inflammatory syndromes during the recovery period. We briefly discuss the impact of HIV infection on the immune system and give an overview of the spectrum of conditions attributed to the Immune Reconstitution Inflammatory syndrome (IRIS). Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Recessive NRL mutations in patients with clumped pigmentary retinal degeneration and relative preservation of blue cone function.

    Science.gov (United States)

    Nishiguchi, Koji M; Friedman, James S; Sandberg, Michael A; Swaroop, Anand; Berson, Eliot L; Dryja, Thaddeus P

    2004-12-21

    Mice lacking the transcription factor Nrl have no rod photoreceptors and an increased number of short-wavelength-sensitive cones. Missense mutations in NRL are associated with autosomal dominant retinitis pigmentosa; however, the phenotype associated with the loss of NRL function in humans has not been reported. We identified two siblings who carried two allelic mutations: a predicted null allele (L75fs) and a missense mutation (L160P) altering a highly conserved residue in the domain involved in DNA-binding-site recognition. In vitro luciferase reporter assays demonstrated that the NRL-L160P mutant had severely reduced transcriptional activity compared with the WT NRL protein, consistent with a severe loss of function. The affected patients had night blindness since early childhood, consistent with a severe reduction in rod function. Color vision was normal, suggesting the presence of all cone color types; nevertheless, a comparison of central visual fields evaluated with white-on-white and blue-on-yellow light stimuli was consistent with a relatively enhanced function of short-wavelength-sensitive cones in the macula. The fundi had signs of retinal degeneration (such as vascular attenuation) and clusters of large, clumped, pigment deposits in the peripheral fundus at the level of the retinal pigment epithelium (clumped pigmentary retinal degeneration). Our report presents an unusual clinical phenotype in humans with loss-of-function mutations in NRL.

  20. Optical Coherence Tomography Angiography Features of Iris Racemose Hemangioma in 4 Cases.

    Science.gov (United States)

    Chien, Jason L; Sioufi, Kareem; Ferenczy, Sandor; Say, Emil Anthony T; Shields, Carol L

    2017-10-01

    Optical coherence tomography angiography (OCTA) allows visualization of iris racemose hemangioma course and its relation to the normal iris microvasculature. To describe OCTA features of iris racemose hemangioma. Descriptive, noncomparative case series at a tertiary referral center (Ocular Oncology Service of Wills Eye Hospital). Patients diagnosed with unilateral iris racemose hemangioma were included in the study. Features of iris racemose hemangioma on OCTA. Four eyes of 4 patients with unilateral iris racemose hemangioma were included in the study. Mean patient age was 50 years, all patients were white, and Snellen visual acuity was 20/20 in each case. All eyes had sectoral iris racemose hemangioma without associated iris or ciliary body solid tumor on clinical examination and ultrasound biomicroscopy. By anterior segment OCT, the racemose hemangioma was partially visualized in all cases. By OCTA, the hemangioma was clearly visualized as a uniform large-caliber vascular tortuous loop with intense flow characteristics superimposed over small-caliber radial iris vessels against a background of low-signal iris stroma. The vascular course on OCTA resembled a light bulb filament (filament sign), arising from the peripheral iris (base of light bulb) and forming a tortuous loop on reaching its peak (midfilament) near the pupil (n = 3) or midzonal iris (n = 1), before returning to the peripheral iris (base of light bulb). Intravenous fluorescein angiography performed in 1 eye depicted the iris hemangioma; however, small-caliber radial iris vessels were more distinct on OCTA than intravenous fluorescein angiography. Optical coherence tomography angiography is a noninvasive vascular imaging modality that clearly depicts the looping course of iris racemose hemangioma. Optical coherence tomography angiography depicted fine details of radial iris vessels, not distinct on intravenous fluorescein angiography.

  1. IRIS Arrays: Observing Wavefields at Multiple Scales and Frequencies

    Science.gov (United States)

    Sumy, D. F.; Woodward, R.; Frassetto, A.

    2014-12-01

    The Incorporated Research Institutions for Seismology (IRIS) provides instruments for creating and operating seismic arrays at a wide range of scales. As an example, for over thirty years the IRIS PASSCAL program has provided instruments to individual Principal Investigators to deploy arrays of all shapes and sizes on every continent. These arrays have ranged from just a few sensors to hundreds or even thousands of sensors, covering areas with dimensions of meters to thousands of kilometers. IRIS also operates arrays directly, such as the USArray Transportable Array (TA) as part of the EarthScope program. Since 2004, the TA has rolled across North America, at any given time spanning a swath of approximately 800 km by 2,500 km, and thus far sampling 2% of the Earth's surface. This achievement includes all of the lower-48 U.S., southernmost Canada, and now parts of Alaska. IRIS has also facilitated specialized arrays in polar environments and on the seafloor. In all cases, the data from these arrays are freely available to the scientific community. As the community of scientists who use IRIS facilities and data look to the future they have identified a clear need for new array capabilities. In particular, as part of its Wavefields Initiative, IRIS is exploring new technologies that can enable large, dense array deployments to record unaliased wavefields at a wide range of frequencies. Large-scale arrays might utilize multiple sensor technologies to best achieve observing objectives and optimize equipment and logistical costs. Improvements in packaging and power systems can provide equipment with reduced size, weight, and power that will reduce logistical constraints for large experiments, and can make a critical difference for deployments in harsh environments or other situations where rapid deployment is required. We will review the range of existing IRIS array capabilities with an overview of previous and current deployments and examples of data and results. We

  2. Longitudinal study of iris concavity, corneal biomechanics, and correlations to ocular biometry in a cohort of 10- to 12-year-old UK schoolboys: 2-year follow-up data.

    Science.gov (United States)

    Shah, Ameet; Lascaratos, Gerassimos; Garway-Heath, David F; Foster, Paul J; Barton, Keith

    2014-06-10

    To explore changes in iris curvature over a 2-year period. To investigate associations between iris curvature and ocular biometric parameters. To explore relationships between a number of nonocular measurements and ocular biometric parameters. Schoolboys enrolled 2 years previously were invited to return for anterior segment optical coherence tomography, corneal hysteresis (CH), corneal resistance factor (CRF), and axial biometric measurements. Refractive error was assessed and measures of height, weight, waist circumference, digit ratio, and percentage body fat taken. Mean spherical equivalent refraction reduced by 0.76 diopters and mean iris concavity, defined as a measurement of less than or equal to -0.1 mm, increased by 0.018 mm at distance fixation and 0.04 mm on accommodation. Compared with 2 years previously, the prevalence of iris concavity increased from 24% to 32% on distance fixation and from 65% to 84% on accommodation. Variables significantly associated with nonaccommodating iris curvature were anterior chamber depth (ACD, P = 0.029) and mean scleral spur angle (P = 0.0001). Variables significantly associated with accommodating iris curvature were ACD (P = 0.02), lens vault (P = 0.047), and scleral spur angle (P Iris concavity was more prevalent in this cohort of schoolboys than 2 years earlier. The degree of concavity remains related to ACD and lens vault. The association between spur-to-spur distance and CH was similar at baseline and after 2 years. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  3. Systemic and Ophthalmologic Findings in Patients with Iris Coloboma

    Directory of Open Access Journals (Sweden)

    Sevda Ertekin

    2013-01-01

    Full Text Available Pur po se: Ocular coloboma is a rare malformation resulting from defective closure of the embryonic optic fissure. It can affect iris, retina, choroid, optic disc or ciliary body. This study reviews the clinical diagnosis and the accompanying ocular and systemic abnormalities in cases of iris coloboma. Ma te ri al and Met hod: Sixteen eyes of ten patients referred to our clinic and diagnosed as iris coloboma were included in the study and were reviewed retrospectively. Re sults: Seven cases were sporadic, and three cases were familial. Isolated iris coloboma was present in only one case, and chorioretinal involvement was present in all the others. Seven cases had involvement of the optic disc. Other ocular anomalies were unilateral microphthalmia in 3 cases, unilateral anophthalmia in 1 case, and unilateral microcornea in one case. Strabismus was present in the familial cases. Dis cus si on: In patients, diagnosed with iris coloboma, routine eye examination should be completed, refractive errors should be corrected, and these patients must be follewed for amblyopia. If strabismus is concominant, surgery can be performed. For potential complications, patients should be checked at regular intervals. (Turk J Ophthalmol 2013; 43: 19-22

  4. Developmental origin of the posterior pigmented epithelium of iris.

    Science.gov (United States)

    Wang, Xiaobing; Xiong, Kai; Lu, Lei; Gu, Dandan; Wang, Songtao; Chen, Jing; Xiao, Honglei; Zhou, Guomin

    2015-03-01

    Iris epithelium is a double-layered pigmented cuboidal epithelium. According to the current model, the neural retina and the posterior iris pigment epithelium (IPE) are derived from the inner wall of the optic cup, while the retinal pigment epithelium (RPE) and the anterior IPE are derived from the outer wall of the optic cup during development. Our current study shows evidence, contradicting this model of fetal iris development. We demonstrate that human fetal iris expression patterns of Otx2 and Mitf transcription factors are similar, while the expressions of Otx2 and Sox2 are complementary. Furthermore, IPE and RPE exhibit identical morphologic development during the early embryonic period. Our results suggest that the outer layer of the optic cup forms two layers of the iris epithelium, and the posterior IPE is the inward-curling anterior rim of the outer layer of the optic cup. These findings provide a reasonable explanation of how IPE cells can be used as an appropriate substitute for RPE cells.

  5. Computational model for transient studies of IRIS pressurizer behavior

    International Nuclear Information System (INIS)

    Rives Sanz, R.; Montesino Otero, M.E.; Gonzalez Mantecon, J.; Rojas Mazaira, L.

    2014-01-01

    International Reactor Innovative and Secure (IRIS) excels other Small Modular Reactor (SMR) designs due to its innovative characteristics regarding safety. IRIS integral pressurizer makes the design of larger pressurizer system than the conventional PWR, without any additional cost. The IRIS pressurizer volume of steam can provide enough margins to avoid spray requirement to mitigate in-surge transient. The aim of the present research is to model the IRIS pressurizer's dynamic using the commercial finite volume Computational Fluid Dynamic code CFX 14. A symmetric tridimensional model equivalent to 1/8 of the total geometry was adopted to reduce mesh size and minimize processing time. The model considers the coexistence of three phases: liquid, steam, and vapor bubbles in liquid volume. Additionally, it takes into account the heat losses between the pressurizer and primary circuit. The relationships for interfacial mass, energy, and momentum transport are programmed and incorporated into CFX by using expressions in CFX Command Language (CCL) format. Moreover, several additional variables are defined for improving the convergence and allow monitoring of boron dilution sequences and condensation-evaporation rate in different control volumes. For transient states a non - equilibrium stratification in the pressurizer is considered. This paper discusses the model developed and the behavior of the system for representative transients sequences such as the in/out-surge transients and boron dilution sequences. The results of analyzed transients of IRIS can be applied to the design of pressurizer internal structures and components. (author)

  6. Proceedings of the IRI Task Force Activity 2001

    International Nuclear Information System (INIS)

    Radicella, S.M.

    2002-08-01

    This ICTP Internal Report contains the list of papers presented, activity report and the write up of a number of presentations delivered during the International Reference Ionosphere (IRI) Task Force Activity 2001 which took place at the Abdus Salam ICTP during May 2001, particularly centred in the week from 21-25 May. The 2001 Task Force Activity is the eighth successful encounter of specialists organized by the URSI-Cospar IRI Working Group and the Aeronomy and Radiopropagation Laboratory of the Abdus Salam International Centre for Theoretical Physics of Trieste, Italy. This project continues the IRI Task Force Activities at the Abdus Salam International Centre for Theoretical Physics (ICTP) in Trieste, Italy. The primary focus of this activity was the development of a specification model for ionospheric variability. Such a model is high on the wish list of users of ionospheric models. Climatological models like IRI provide monthly mean values of ionospheric parameters. Understandably a satellite designer or operator needs to know not only the monthly average conditions but also the expected deviations from these mean values. The main discussions and presentations took place during the week 21-25 May. The format was similar to last year's activity with presentations and round-table discussions in the morning and follow-on work in small subgroups in front of computer terminals in the afternoon. This Proceedings contains also four papers of the previous IRI Task Force Activity which were omitted

  7. The influence of iris color on the pupillary light reflex.

    Science.gov (United States)

    Bergamin, O; Schoetzau, A; Sugimoto, K; Zulauf, M

    1998-08-01

    This study was carried out to investigate the effect of iris color on the pupillary light reflex (PLR) in normal healthy volunteers. Pupil perimetry was performed on 50 healthy volunteers with the Octopus 1-2-3 automated perimeter. Within the 30-deg visual field, 33 test locations were investigated four times. Stimulus parameters were Goldmann size V (1.72 degrees), intensity 1632 cd/m2, stimulus time 200 ms, background illumination 0 cd/m2, and interstimulus interval 3 s. Pupillometric parameters studied were initial pupil size, amplitude (magnitude of pupillary contraction), latency time, contraction time, pre-PLR movement, contraction velocity, and redilation velocity. Pupillometric parameters were investigated by analysis of variance by the independent variables blue and brown irides. Iris color (blue vs brown) influenced statistically significantly (P movement (0.328 mm2/s vs 0.325 mm2/s). Pupillary contraction amplitude and velocity depended on iris color, whereas pupil size and latency time were independent of iris color. Therefore, iris color might be considered when, evaluating pupillary movements in pupil perimetry.

  8. The design and safety features of the IRIS reactor

    International Nuclear Information System (INIS)

    Carelli, Mario D.; Conway, L.E.; Oriani, L.; Petrovic, B.; Lombardi, C.V.; Ricotti, M.E.; Barroso, A.C.O.; Collado, J.M.; Cinotti, L.; Todreas, N.E.; Grgic, D.; Moraes, M.M.; Boroughs, R.D.; Ninokata, H.; Ingersoll, D.T.; Oriolo, F.

    2004-01-01

    Salient features of the International Reactor Innovative and Secure (IRIS) are presented here. IRIS, an integral, modular, medium size (335 MWe) PWR, has been under development since the turn of the century by an international consortium led by Westinghouse and including over 20 organizations from nine countries. Described here are the features of the integral design which includes steam generators, pumps and pressurizer inside the vessel, together with the core, control rods, and neutron reflector/shield. A brief summary is provided of the IRIS approach to extended maintenance over a 48-month schedule. The unique IRIS safety-by-design approach is discussed, which, by eliminating accidents, at the design stage, or decreasing their consequences/probabilities when outright elimination is not possible, provides a very powerful first level of defense in depth. The safety-by-design allows a significant reduction and simplification of the passive safety systems, which are presented here, together with an assessment of the IRIS response to transients and postulated accidents

  9. Iris structure and minor physical anomalies in schizophrenia.

    Science.gov (United States)

    Trixler, Dániel; Tényi, Tamás

    2017-10-01

    This study compared five human iris characteristics and minor physical anomalies (MPAs) between patients with schizophrenia (n = 32) and controls (n = 31). Correlations between iris characteristics and MPAs were expected, due to their same ectodermic origin. Iris macro photos were taken and quantified in five categories mentioned before. MPAs were also examined in both groups. Our results show significant differences in the frequency of pigment dots of the iris and total number of MPAs between groups. Other significant differences were found in the extension of concentric furrows, as they were more common in healthy subjects, while Wolfflin nodules occurred significantly more often in patients with schizophrenia. Expected difference in Fuch's crypts could not be observed between groups. Light eye color was positively correlated to pigment dots and Wolfflin nodules, and negatively correlated with concentric furrows. Dark eye color showed positive correlation with concentric furrows, and negative correlation with pigment dots and concentric furrows. A gender effect could also been observed: male individuals showed moderate positive correlations between pigment dots and total MPAs frequency, while this couldn't be observed in the female group. Our findings suggest possible connections between iris characteristics and MPAs, where males are more prone to deviations. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Efficient iris texture analysis method based on Gabor ordinal measures

    Science.gov (United States)

    Tajouri, Imen; Aydi, Walid; Ghorbel, Ahmed; Masmoudi, Nouri

    2017-07-01

    With the remarkably increasing interest directed to the security dimension, the iris recognition process is considered to stand as one of the most versatile technique critically useful for the biometric identification and authentication process. This is mainly due to every individual's unique iris texture. A modestly conceived efficient approach relevant to the feature extraction process is proposed. In the first place, iris zigzag "collarette" is extracted from the rest of the image by means of the circular Hough transform, as it includes the most significant regions lying in the iris texture. In the second place, the linear Hough transform is used for the eyelids' detection purpose while the median filter is applied for the eyelashes' removal. Then, a special technique combining the richness of Gabor features and the compactness of ordinal measures is implemented for the feature extraction process, so that a discriminative feature representation for every individual can be achieved. Subsequently, the modified Hamming distance is used for the matching process. Indeed, the advanced procedure turns out to be reliable, as compared to some of the state-of-the-art approaches, with a recognition rate of 99.98%, 98.12%, and 95.02% on CASIAV1.0, CASIAV3.0, and IIT Delhi V1 iris databases, respectively.

  11. A Study on Iris Localization and Recognition on Mobile Phones

    Directory of Open Access Journals (Sweden)

    Dae Sik Jeong

    2007-11-01

    Full Text Available A new iris recognition method for mobile phones based on corneal specular reflections (SRs is discussed. We present the following three novelties over previous research. First, in case of user with glasses, many noncorneal SRs may happen on the surface of glasses and it is very difficult to detect genuine SR on the cornea. To overcome such problems, we propose a successive on/off dual illuminator scheme to detect genuine SRs on the corneas of users with glasses. Second, to detect SRs robustly, we estimated the size, shape, and brightness of the SRs based on eye, camera, and illuminator models. Third, the detected eye (iris region was verified again using the AdaBoost eye detector. Experimental results with 400 face images captured from 100 persons with a mobile phone camera showed that the rate of correct iris detection was 99.5% (for images without glasses and 98.9% (for images with glasses or contact lenses. The consequent accuracy of iris authentication was 0.05% of the EER (equal error rate based on detected iris images.

  12. Efficient iris recognition by characterizing key local variations.

    Science.gov (United States)

    Ma, Li; Tan, Tieniu; Wang, Yunhong; Zhang, Dexin

    2004-06-01

    Unlike other biometrics such as fingerprints and face, the distinct aspect of iris comes from randomly distributed features. This leads to its high reliability for personal identification, and at the same time, the difficulty in effectively representing such details in an image. This paper describes an efficient algorithm for iris recognition by characterizing key local variations. The basic idea is that local sharp variation points, denoting the appearing or vanishing of an important image structure, are utilized to represent the characteristics of the iris. The whole procedure of feature extraction includes two steps: 1) a set of one-dimensional intensity signals is constructed to effectively characterize the most important information of the original two-dimensional image; 2) using a particular class of wavelets, a position sequence of local sharp variation points in such signals is recorded as features. We also present a fast matching scheme based on exclusive OR operation to compute the similarity between a pair of position sequences. Experimental results on 2255 iris images show that the performance of the proposed method is encouraging and comparable to the best iris recognition algorithm found in the current literature.

  13. IRISpy: Analyzing IRIS Data in Python

    Science.gov (United States)

    Ryan, Daniel; Christe, Steven; Mumford, Stuart; Baruah, Ankit; Timothy, Shelbe; Pereira, Tiago; De Pontieu, Bart

    2017-08-01

    IRISpy is a new community-developed open-source software library for analysing IRIS level 2 data. It is written in Python, a free, cross-platform, general-purpose, high-level programming language. A wide array of scientific computing software packages have already been developed in Python, from numerical computation (NumPy, SciPy, etc.), to visualization and plotting (matplotlib), to solar-physics-specific data analysis (SunPy). IRISpy is currently under development as a SunPy-affiliated package which means it depends on the SunPy library, follows similar standards and conventions, and is developed with the support of of the SunPy development team. IRISpy’s has two primary data objects, one for analyzing slit-jaw imager data and another for analyzing spectrograph data. Both objects contain basic slicing, indexing, plotting, and animating functionality to allow users to easily inspect, reduce and analyze the data. As part of this functionality the objects can output SunPy Maps, TimeSeries, Spectra, etc. of relevant data slices for easier inspection and analysis. Work is also ongoing to provide additional data analysis functionality including derivation of systematic measurement errors (e.g. readout noise), exposure time correction, residual wavelength calibration, radiometric calibration, and fine scale pointing corrections. IRISpy’s code base is publicly available through github.com and can be contributed to by anyone. In this poster we demonstrate IRISpy’s functionality and future goals of the project. We also encourage interested users to become involved in further developing IRISpy.

  14. The radiology of IRIS (immune reconstitution inflammatory syndrome) in patients with mycobacterial tuberculosis and HIV co-infection: appearances in 11 patients

    International Nuclear Information System (INIS)

    Rajeswaran, G.; Becker, J.L.; Michailidis, C.; Pozniak, A.L.; Padley, S.P.G.

    2006-01-01

    Aim: To determine the radiological manifestations of IRIS (immune reconstitution inflammatory syndrome) in patients with HIV and mycobacterium tuberculosis co-infection, in the context of their demographic and clinical data. Materials and methods: The radiological imaging, demographic and clinical data of 11 patients diagnosed with IRIS associated with HIV and mycobacterial tuberculosis co-infection were studied retrospectively. Where available, follow-up imaging studies were also reviewed. Results: The most common radiological feature of IRIS was lymph node enlargement (73%), with central low attenuation centres, in keeping with necrosis, present in most of these cases (88%). Most commonly affected were intra-abdominal nodes (70%), followed by axillary (40%) and mediastinal lymph nodes (36%). Within the lung parenchyma, diffuse, bilateral pulmonary nodules were seen in 55% of cases. Unilateral small volume pleural effusions were seen in two cases with associated parenchymal changes seen in only one. Small volume ascites was seen in two cases. Thirty-six percent of cases presented with new or worsening abscesses despite treatment. In this context, image-guided radiological drainage proved a useful adjunct to the conventional medical therapy for IRIS. The most common clinical signs of IRIS included fever (64%), abdominal pain (36%) and cough (27%). Conclusion: We have described the radiological features that are characteristic in IRIS and the importance of putting these into context with the clinical and pathological findings as part of a multidisciplinary approach in making the diagnosis. The role of the radiologist is central in diagnosis, monitoring of disease progression and management of complications in patients with IRIS

  15. Fusion of phase congruency and harris algorithm for extraction of iris corner points

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, G

    2015-12-01

    Full Text Available iris identification systems. Low cost devices used under uncontrolled environments acquire poor iris images with inconsistent illumination and specular reflections. These factors inflict challenges towards the accurate identification and extraction...

  16. Visual outcome after corneal transplantation for corneal perforation and iris prolapse in 37 horses

    DEFF Research Database (Denmark)

    Henriksen, Michala de Linde; Plummer, C. E.; Mangan, B.

    2012-01-01

    We wanted to investigate the visual outcome of horses presented with iris prolapse and treated with corneal transplantation.......We wanted to investigate the visual outcome of horses presented with iris prolapse and treated with corneal transplantation....

  17. Ethnicity prediction and classification from iris texture patterns: A survey on recent advances

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, Gugulethu

    2017-03-01

    Full Text Available The prediction and classification of ethnicity based on iris texture patterns using image processing, artificial intelligence and computer vision techniques is still a recent topic in iris biometrics. While the large body of knowledge and research...

  18. Let the IRIS Bloom:Regrowing the integrated risk information system (IRIS) of the U.S. Environmental Protection Agency.

    Science.gov (United States)

    Dourson, Michael L

    2018-05-03

    The Integrated Risk Information System (IRIS) of the U.S. Environmental Protection Agency (EPA) has an important role in protecting public health. Originally it provided a single database listing official risk values equally valid for all Agency offices, and was an important tool for risk assessment communication across EPA. Started in 1986, IRIS achieved full standing in 1990 when it listed 500 risk values, the effort of two senior EPA groups over 5 years of monthly face-to-face meetings, to assess combined risk data from multiple Agency offices. Those groups were disbanded in 1995, and the lack of continuing face-to-face meetings meant that IRIS became no longer EPA's comprehensive database of risk values or their latest evaluations. As a remedy, a work group of the Agency's senior scientists should be re-established to evaluate new risks and to update older ones. Risk values to be reviewed would come from the same EPA offices now developing such information on their own. Still, this senior group would have the final authority on posting a risk value in IRIS, independently of individual EPA offices. This approach could also lay the groundwork for an all-government IRIS database, especially needed as more government Agencies, industries and non-governmental organizations are addressing evolving risk characterizations. Copyright © 2018. Published by Elsevier Inc.

  19. Texture Feature Extraction and Classification for Iris Diagnosis

    Science.gov (United States)

    Ma, Lin; Li, Naimin

    Appling computer aided techniques in iris image processing, and combining occidental iridology with the traditional Chinese medicine is a challenging research area in digital image processing and artificial intelligence. This paper proposes an iridology model that consists the iris image pre-processing, texture feature analysis and disease classification. To the pre-processing, a 2-step iris localization approach is proposed; a 2-D Gabor filter based texture analysis and a texture fractal dimension estimation method are proposed for pathological feature extraction; and at last support vector machines are constructed to recognize 2 typical diseases such as the alimentary canal disease and the nerve system disease. Experimental results show that the proposed iridology diagnosis model is quite effective and promising for medical diagnosis and health surveillance for both hospital and public use.

  20. A plant control system development approach for IRIS

    International Nuclear Information System (INIS)

    Wood, R.T.; Brittain, C.R.; March-Leuba, J.A.; Conway, L.E.; Oriani, L.

    2003-01-01

    The plant control system concept for the International Reactor Innovative and Secure (IRIS) will make use of integrated control, diagnostic, and decision modules to provide a highly automated intelligent control capability. The plant control system development approach established for IRIS involves determination and verification of control strategies based on whole-plant simulation; identification of measurement, control, and diagnostic needs; development of an architectural framework in which to integrate an intelligent plant control system; and design of the necessary control and diagnostic elements for implementation and validation. This paper describes key elements of the plant control system development approach established for IRIS and presents some of the strategies and methods investigated to support the desired control capabilities. (author)

  1. Computer modeling of homogenization of boric acid in IRIS pressurizer

    International Nuclear Information System (INIS)

    Rives Sanz, Ronny; Montesinos Otero, Maria Elena; Gonzalez Mantecon, Javier

    2015-01-01

    Integral layout of nuclear reactor IRIS makes possible the elimination of the spray system; which is usually used to mitigate in-surge transient and help to boron homogenization. The study of transients with deficiencies in the boron homogenization in this technology is very important, because they can cause disturbances in the reactor power and insert a strong reactivity in the core. The aim of the present research is to model the IRIS pressurizer using the CFX code searching for designs alternatives that guaranteed its intrinsic security, focused on the phenomena before mentioned. A symmetric tri dimensional model equivalent to 1/8 of the total geometry was adopted to reduce mesh size and minimize processing time. The relationships are programmed and incorporated into the code. This paper discusses the model developed and the behavior of the system for representative transients sequences. The results of the analyzed IRIS transients could be applied to the design of the pressurizer internal structures and components. (Author)

  2. Iris recognition using image moments and k-means algorithm.

    Science.gov (United States)

    Khan, Yaser Daanial; Khan, Sher Afzal; Ahmad, Farooq; Islam, Saeed

    2014-01-01

    This paper presents a biometric technique for identification of a person using the iris image. The iris is first segmented from the acquired image of an eye using an edge detection algorithm. The disk shaped area of the iris is transformed into a rectangular form. Described moments are extracted from the grayscale image which yields a feature vector containing scale, rotation, and translation invariant moments. Images are clustered using the k-means algorithm and centroids for each cluster are computed. An arbitrary image is assumed to belong to the cluster whose centroid is the nearest to the feature vector in terms of Euclidean distance computed. The described model exhibits an accuracy of 98.5%.

  3. Innovative features and fuel design approach in the iris reactor

    International Nuclear Information System (INIS)

    Petrovic, B.; Carelli, M.; Greenspan, E.; Matsumoto, H.; Padovani, E.; Ganda, F.

    2002-01-01

    The International Reactor Innovative and Secure (IRIS) is being developed by an international consortium of industry, laboratory, university and utility establishments, led by Westinghouse. The IRIS design addresses key requirements associated with advanced reactors, including improved safety, enhanced proliferation resistance, competitive electricity production cost, and improved waste management. IRIS is a modular, small/medium size (335 MWe) PWR with an integral vessel configuration. The objective has been to base its design on proven LWR technology, so that no new technology development is needed and near-term deployment is possible, yet at the same time to introduce innovative features making it attractive when compared to present PWRs. These opposing requirements resulted in an evolutionary approach to fuel and core design, balancing new features against the need to avoid extensive testing and demonstration programmes. (author)

  4. [Comparative clinical study of wavefront-guided laser in situ keratomileusis with versus without iris recognition for myopia or myopic astigmatism].

    Science.gov (United States)

    Wang, Wei-qun; Zhang, Jin-song; Zhao, Xiao-jin

    2011-10-01

    To explore the postoperative visual acuity results of wavefront-guided LASIK with iris recognition for myopia or myopic astigmatism and the changes of higher-order aberrations and contrast sensitivity function (CSF). Series of prospective case studies, 158 eyes (85 cases) of myopia or myopic astigmatism were divided into two groups: one group underwent wavefront-guided LASIK with iris recognition (iris recognition group); another group underwent wavefront-guided LASIK treatment without iris recognition through the limbus maring point (non-iris recognition group). To comparative analyze the postoperative visual acuity, residual refraction, the RMS of higher-order aberrations and CSF of two groups. There was no statistical significance difference between two groups of the average uncorrected visual acuity (t = 0.039, 0.058, 0.898; P = 0.844, 0.810, 0.343), best corrected visual acuity (t = 0.320, 0.440, 1.515; P = 0.572, 0.507, 0.218), and residual refraction [spherical equivalent (t = 0.027, 0.215, 0.238; P = 0.869, 0.643, 0.626), spherical (t = 0.145, 0.117, 0.038; P = 0.704, 0.732, 0.845) and cylinder (t = 1.676, 1.936, 0.334; P = 0.195, 0.164, 0.563)] at postoperative 10 days, 1 month and 3 month. The security index of iris recognition group at postoperative 3 month was 1.06 and non-iris recognition group was 1.03; the efficacy index of iris recognition group is 1.01 and non-iris recognition group was 1.00. Postoperative 3 month iris recognition group 93.83% eyes and non-iris recognition group of 90.91% eyes spherical equivalent within ± 0.50 D (χ(2) = 0.479, P = 0.489), iris recognition group of 98.77% eyes and non-iris recognition group of 97.40% eyes spherical equivalent within ± 1.00 D (Fisher test, P = 0.613). There was no significance difference between the two groups of security, efficacy and predictability. Non-iris recognition group postoperative 1 month and postoperative 3 months 3-order order aberrations root mean square value (RMS) higher than the

  5. Iris recognition in less constrained environments: a video-based approach

    OpenAIRE

    Mahadeo, Nitin Kumar

    2017-01-01

    This dissertation focuses on iris biometrics. Although the iris is the most accurate biometric, its adoption has been relatively slow. Conventional iris recognition systems utilize still eye images captured in ideal environments and require highly constrained subject presentation. A drop in recognition performance is observed when these constraints are removed as the quality of the data acquired is affected by heterogeneous factors. For iris recognition to be widely adopted, it can therefore ...

  6. Detection of UV-induced pigmentary and epidermal changes over time using in vivo reflectance confocal microscopy

    NARCIS (Netherlands)

    Middelkamp-Hup, Maritza A.; Park, H.-Y.; Lee, Jin; Gilchrest, Barbara A.; Gonzalez, Salvador

    2006-01-01

    In vivo reflectance confocal microscopy (RCM) provides high-resolution optical sections of the skin in its native state, without needing to fix or section the tissue. Melanin provides an excellent contrast for RCM, giving a bright signal in the confocal images. The pigmented guinea-pig is a common

  7. Pigmentary and photonic coloration mechanisms reveal taxonomic relationships of the Cattlehearts (Lepidoptera: Papilionidae: Parides)

    NARCIS (Netherlands)

    Wilts, Bodo D.; Ijbema, Natasja; Stavenga, Doekele G.

    2014-01-01

    Background: The colorful wing patterns of butterflies, a prime example of biodiversity, can change dramatically within closely related species. Wing pattern diversity is specifically present among papilionid butterflies. Whether a correlation between color and the evolution of these butterflies

  8. Thirty Years of Innovation in Seismology with the IRIS Consortium

    Science.gov (United States)

    Sumy, D. F.; Woodward, R.; Aderhold, K.; Ahern, T. K.; Anderson, K. R.; Busby, R.; Detrick, R. S.; Evers, B.; Frassetto, A.; Hafner, K.; Simpson, D. W.; Sweet, J. R.; Taber, J.

    2015-12-01

    The United States academic seismology community, through the National Science Foundation (NSF)-funded Incorporated Research Institutions for Seismology (IRIS) Consortium, has promoted and encouraged a rich environment of innovation and experimentation in areas such as seismic instrumentation, data processing and analysis, teaching and curriculum development, and academic science. As the science continually evolves, IRIS helps drive the market for new research tools that enable science by establishing a variety of standards and goals. This has often involved working directly with manufacturers to better define the technology required, co-funding key development work or early production prototypes, and purchasing initial production runs. IRIS activities have helped establish de-facto international standards and impacted the commercial sector in areas such as seismic instrumentation, open-access data management, and professional development. Key institutional practices, conducted and refined over IRIS' thirty-year history of operations, have focused on open-access data availability, full retention of maximum-bandwidth, continuous data, and direct community access to state-of-the-art seismological instrumentation and software. These practices have helped to cultivate and support a thriving commercial ecosystem, and have been a key element in the professional development of multiple generations of seismologists who now work in both industry and academia. Looking toward the future, IRIS is increasing its engagement with industry to better enable bi-directional exchange of techniques and technology, and enhancing the development of tomorrow's workforce. In this presentation, we will illustrate how IRIS has promoted innovations grown out of the academic community and spurred technological advances in both academia and industry.

  9. Association of iris crypts with acute primary angle closure.

    Science.gov (United States)

    Koh, Victor; Chua, Jacqueline; Shi, Yuan; Thakku, Sri Gowtham; Lee, Ryan; Nongpiur, Monisha E; Baskaran, Mani; Kumar, Rajesh S; Perera, Shamira; Aung, Tin; Cheng, Ching-Yu

    2017-10-01

    To determine the relationship between iris surface features and acute primary angle closure (APAC) in eyes with angle closure. Case-control study involving Asian patients diagnosed with previous APAC, primary angle closure suspect (PACS), primary angle closure (PAC) and primary angle closure glaucoma (PACG) at an eye centre in Singapore between August 2012 and January 2015. Participants underwent ophthalmic examination and digital slit-lamp iris photography. Iris surface features were graded based on crypts, furrows and colour. Fellow eyes of APAC were compared with PACS and PAC/PACG eyes with regard to their iris surface features. Occurrence of APAC. A total of 309 patients (71 APAC, 139 PACS, 47 PAC and 52 PACG) were included (mean age: 67.7±7.2 years and 36.6% male). Compared with PACS, higher crypt grade was significantly associated with lower odds of APAC (OR=0.58 for one grade higher in crypt grade; p=0.027, adjusted for age, gender, ethnicity and pupil diameter). The results remained similar when compared with PAC/PACG group (OR=0.58 for one grade higher in crypt grade; p=0.043). We did not observe any significant associations between iris furrows or colour with presence of APAC. Our study comprising Asian eyes with angle closure suggests that the presence of a higher crypt grading may be protective for APAC. As such, assessing iris surface architecture for crypts could be a new measure for risk stratification of developing APAC in eyes with angle closure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Iris ultrastructure in patients with synechiae as revealed by in vivo laser scanning confocal microscopy : In vivo iris ultrastructure in patients with Synechiae by Laser Scanning Confocal Microscopy.

    Science.gov (United States)

    Li, Ming; Cheng, Hongbo; Guo, Ping; Zhang, Chun; Tang, Song; Wang, Shusheng

    2016-04-26

    Iris plays important roles in ocular physiology and disease pathogenesis. Currently it is technically challenging to noninvasively examine the human iris ultrastructure in vivo. The purpose of the current study is to reveal human iris ultrastructure in patients with synechiae by using noninvasive in vivo laser scanning confocal microscopy (LSCM). The ultrastructure of iris in thirty one patients, each with synechiae but transparent cornea, was examined by in vivo LSCM. Five characteristic iris ultrastructures was revealed in patients with synechiae by in vivo LSCM, which include: 1. tree trunk-like structure; 2. tree branch/bush-like structure; 3. Fruit-like structure; 4. Epithelioid-like structure; 5. deep structure. Pigment granules can be observed as a loose structure on the top of the arborization structure. In iris-associated diseases with Tyndall's Phenomenon and keratic precipitates, the pigment particles are more likely to fall off from the arborization structure. The ultrastructure of iris in patients with synechiae has been visualized using in vivo LSCM. Five iris ultrastructures can be clearly observed, with some of the structures maybe disease-associated. The fall-off of the pigment particles may cause the Tyndall's Phenomenon positive. In vivo LSCM provides a non-invasive approach to observe the human iris ultrastructure under certain eye disease conditions, which sets up a foundation to visualize certain iris-associated diseases in the future.

  11. The IRIS consortium: international cooperation in advanced reactor development

    International Nuclear Information System (INIS)

    Carelli, M.; Petrovic, B.; Miller, K.; Lombardi, C.; Ricotti, M.E.

    2005-01-01

    Besides its many outstanding technical innovations in the design and safety, the most innovative feature of the International Reactor Innovative and Secure (IRIS), is perhaps the international cooperation which carries on its development. IRIS is designed by an international consortium which currently numbers 21 organizations from ten countries across four continents. It includes reactor, fuel and fuel cycle vendors, component manufacturers, laboratories, academia, architect engineers and power producers. The defining organizational characteristics of IRIS is that while Westinghouse has overall lead and responsibility, this lead is of the type of 'primus inter pares' (first among equals) rather than the traditional owner versus suppliers/contractors relationship. All members of the IRIS consortium contribute and expect to have a return, should IRIS be successfully deployed, commensurate to their investment. The nature of such return will be tailored to the type of each organization, because it will of course be of a different nature for say a component manufacturer, university, or architect engineer. One fundamental tenet of the consortium is that all members, regardless of their amount of contribution, have equal access to all information developed within the project. Technical work is thus being coordinated by integrated subgroups and the whole team meets twice a year to perform an overall review of the work, discuss policy and strategy and plan future activities. Personnel from consortium members have performed internships, mostly at Westinghouse locations in Pittsburgh, Pennsylvania, and Windsor, Connecticut, but also at other members, as it has been the case for several graduate students. In fact, more than one hundred students at the various universities have been working on IRIS, most of them conducting graduate theses at the master or doctoral level. The IRIS experience has proved very helpful to the students in successfully landing their employment choice

  12. Proceedings of the IRI Task Force Activity 2002. 1. ed

    International Nuclear Information System (INIS)

    Radicella, S.M.

    2003-06-01

    This ICTP Internal Report contains the list of papers presented, activity reports and the write up of a number of presentations delivered during the International Reference Ionosphere (IRI) Task Force Activity 2002 which took place at the Abdus Salam ICTP during August 2002. The 2002 Task Force Activity is the ninth successful encounter of specialists organized by the URSI-Cospar IRI Working Group and the Aeronomy and Radiopropagation Laboratory of the Abdus Salam International Centre for Theoretical Physics of Trieste, Italy. The main topics of the meeting were ionosphere variability and topside ionosphere

  13. Increasing the information acquisition volume in iris recognition systems.

    Science.gov (United States)

    Barwick, D Shane

    2008-09-10

    A significant hurdle for the widespread adoption of iris recognition in security applications is that the typically small imaging volume for eye placement results in systems that are not user friendly. Separable cubic phase plates at the lens pupil have been shown to ameliorate this disadvantage by increasing the depth of field. However, these phase masks have limitations on how efficiently they can capture the information-bearing spatial frequencies in iris images. The performance gains in information acquisition that can be achieved by more general, nonseparable phase masks is demonstrated. A detailed design method is presented, and simulations using representative designs allow for performance comparisons.

  14. Radiotherapy of the juvenile xanthogranuloma of the iris

    Energy Technology Data Exchange (ETDEWEB)

    Keinert, K; Lukassek, B; Thieme, R; Schumann, E

    1981-01-01

    A report is given on an eight months old child with a juvenile xanthogranuloma of the iris and a secondary glaucoma. After radiotherapy with 6 x 0,5 Gy under conventional deep therapy conditions, a regression of the increased intraocular pressure was observed. In case of a juvenile xanthogranuloma of the iris, this secondary glaucoma represents in any case an acute danger to the eye, so it must be treated immediately. Radiotherapy has to be considered as the method of choice; it is also discussed with regard to the risk and the avoidance of a radiation cataract which, however, has to be tolerated in certain cases in order to prevent greater troubles.

  15. IRIS Responsiveness to Generation IV Road-map Goals

    International Nuclear Information System (INIS)

    Carelli, M.D.; Paramonov, D.V.; Petrovic, B.

    2002-01-01

    The DOE Generation IV road-map process is in its second and final year. Almost one hundred concepts submitted from all over the world have been reviewed against the Generation IV goals of resources sustainability; safety and reliability; and, economics. Advanced LWRs are taken as the reference point. IRIS (International Reactor Innovative and Secure), a 100-335 MWe integral light water reactor being developed by a vast international consortium led by Westinghouse, is one on the concepts being considered in the road-map and is perhaps the most visible representative of the concept set known as Integral Primary System Reactors (IPSR). This paper presents how IRIS satisfies the prescribed goals. The first goal of resource sustainability includes criteria like utilization of fuel resources, amount and toxicity of waste produced, environmental impact, proliferation and sabotage resistance. As a thermal reactor IRIS does not have the same fuel utilization as fast reactors. However, it has a significant flexibility in fuel cycles as it is designed to utilize either UO 2 or MOX with straight burn cycles of 4 to 10 years, depending on the fissile content. High discharge burnup and Pu recycling result in good fuel utilization and lower waste; IRIS has also attractive proliferation resistance characteristics, due to the reduced accessibility of the fuel. The safety and reliability goal include reliability, workers' exposure, robust safety features, models with well characterized uncertainty, source term and mechanisms of energy release, robust mitigation of accidents. IRIS is significantly better than advanced LWRs because of its safety by design which eliminates a variety of accidents such as LOCAs, its containment vessel coupled design which maintains the core safely covered during the accident sequences, its design simplification features such as no (or reduced) soluble boron, internal shielding and four-year refueling/maintenance interval which significantly reduce

  16. IRIS Toxicological Review of Ethylene Glycol Mono-Butyl ...

    Science.gov (United States)

    EPA released the draft report, Toxicological Review for Ethylene Glycol Mono-Butyl Ether , that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of EGBE that will appear on the Integrated Risk Information System (IRIS) database.

  17. IRIS Toxicological Review of 2,2',4,4'-Tetrabromodiphenyl ...

    Science.gov (United States)

    The U.S. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessments of congeners of polybrominated diphenyl ethers (PDBEs), this review is about 2,2',4,4'-Tetrabromodiphenyl Ether, or commonly referred to as tetraBDE (BDE-47). Following the external peer review this assessment will appear in the Integrated Risk Information System (IRIS) database. Peer review will ensure that science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. EPA is updating the Integrated Risk Information System (IRIS) health assessments for the PBDEs.

  18. Investigation on equatorial ionospheric profiles and IRI model

    International Nuclear Information System (INIS)

    Adeniyi, J.O.

    1996-01-01

    Ionospheric profiles below the F2 peak ionisation density are compared with those of the International Reference Ionosphere (IRI). The data used are those of Ibadan (Lat. 7.4 deg N, Long. 3.9 E). The IRI model gives a much thinner bottomside F region ionisation density than what is observed experimentally, in winter; both at high and low solar activity. Similar departures are observed in the summer of both solar epoch but on a reduced scale. The closet agreement occurs during the March equinox of high solar activity. (author). 3 refs, 4 figs

  19. IRIS Toxicological Review of 2-Hexanone (External Review ...

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 2-hexanone that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. 2-Hexanone was nominated for IRIS assessment because of its frequent detection at sites nation-wide and its occurrence as a byproduct of certain industrial processes.

  20. Peripheral laser iridoplasty opens angle in plateau iris by thinning the cross-sectional tissues

    Directory of Open Access Journals (Sweden)

    Liu J

    2013-09-01

    Full Text Available Ji Liu,1,2 Tania Lamba,1 David A Belyea1 1Department of Ophthalmology, The George Washington University, Washington DC, USA; 2Yale Eye Center, Yale University, New Haven, CT, USA Abstract: Plateau iris syndrome has been described as persistent angle narrowing or occlusion with intraocular pressure elevation after peripheral iridotomy due to the abnormal plateau iris configuration. Argon laser peripheral iridoplasty (ALPI is an effective adjunct procedure to treat plateau iris syndrome. Classic theory suggests that the laser causes the contraction of the far peripheral iris stroma, "pulls" the iris away from the angle, and relieves the iris-angle apposition. We report a case of plateau iris syndrome that was successfully treated with ALPI. Spectral domain optical coherence tomography confirmed the angle was open at areas with laser treatment but remained appositionally closed at untreated areas. Further analysis suggested significant cross-sectional thinning of the iris at laser-treated areas in comparison with untreated areas. The findings indicate that APLI opens the angle, not only by contracting the iris stroma, but also by thinning the iris tissue at the crowded angle. This is consistent with the ALPI technique to aim at the iris as far peripheral as possible. This case also suggests that spectral domain optical coherence tomography is a useful adjunct imaging tool to gonioscopy in assessing the angle condition. Keywords: plateau iris, optic coherence tomography, argon laser peripheral iridoplasty, angle-closure glaucoma

  1. Expression of defender against apoptotic death (DAD-1) in iris and dianthus petals

    NARCIS (Netherlands)

    Kop, van der D.A.M.; Ruys, G.; Dees, D.; Schoot, van der C.; Boer, de A.D.; Doorn, van W.G.

    2003-01-01

    The gene defender against apoptotic death (DAD-1) prevents programmed cell death in animal cells. We investigated the expression pattern of DAD-1 in petals of iris (Iris x hollandica cv. Blue Magic) and carnation (Dianthus caryophyllus cv. Etarro). DAD-1 expression in Iris petals was strongly

  2. IRIS Assessment Plan for Ammonia and Ammonium Salts Noncancer Oral (Scoping and Problem Formulation Materials)

    Science.gov (United States)

    In April 2018, EPA released the draft IRIS Assessment Plan for Ammonia and Ammonium Salts Noncancer Oral. An IRIS Assessment Plan (IAP) communicates to the public the plan for assessing each individual chemical and includes summary information on the IRIS Program’s sco...

  3. An Analysis on Better Testing than Training Performances on the Iris Dataset

    NARCIS (Netherlands)

    Schutten, Marten; Wiering, Marco

    2016-01-01

    The Iris dataset is a well known dataset containing information on three different types of Iris flowers. A typical and popular method for solving classification problems on datasets such as the Iris set is the support vector machine (SVM). In order to do so the dataset is separated in a set used

  4. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) (Public Comment Draft)

    Science.gov (United States)

    In September 2016, the U.S. Environmental Protection Agency's (USEPA) released the draft Integrated Risk Information System (IRIS) Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE). Consistent with the 2013 IRIS Enhancements, draft IRIS assessments are released prior to e...

  5. An automatic iris occlusion estimation method based on high-dimensional density estimation.

    Science.gov (United States)

    Li, Yung-Hui; Savvides, Marios

    2013-04-01

    Iris masks play an important role in iris recognition. They indicate which part of the iris texture map is useful and which part is occluded or contaminated by noisy image artifacts such as eyelashes, eyelids, eyeglasses frames, and specular reflections. The accuracy of the iris mask is extremely important. The performance of the iris recognition system will decrease dramatically when the iris mask is inaccurate, even when the best recognition algorithm is used. Traditionally, people used the rule-based algorithms to estimate iris masks from iris images. However, the accuracy of the iris masks generated this way is questionable. In this work, we propose to use Figueiredo and Jain's Gaussian Mixture Models (FJ-GMMs) to model the underlying probabilistic distributions of both valid and invalid regions on iris images. We also explored possible features and found that Gabor Filter Bank (GFB) provides the most discriminative information for our goal. Finally, we applied Simulated Annealing (SA) technique to optimize the parameters of GFB in order to achieve the best recognition rate. Experimental results show that the masks generated by the proposed algorithm increase the iris recognition rate on both ICE2 and UBIRIS dataset, verifying the effectiveness and importance of our proposed method for iris occlusion estimation.

  6. A novel iris patterns matching algorithm of weighted polar frequency correlation

    Science.gov (United States)

    Zhao, Weijie; Jiang, Linhua

    2014-11-01

    Iris recognition is recognized as one of the most accurate techniques for biometric authentication. In this paper, we present a novel correlation method - Weighted Polar Frequency Correlation(WPFC) - to match and evaluate two iris images, actually it can also be used for evaluating the similarity of any two images. The WPFC method is a novel matching and evaluating method for iris image matching, which is complete different from the conventional methods. For instance, the classical John Daugman's method of iris recognition uses 2D Gabor wavelets to extract features of iris image into a compact bit stream, and then matching two bit streams with hamming distance. Our new method is based on the correlation in the polar coordinate system in frequency domain with regulated weights. The new method is motivated by the observation that the pattern of iris that contains far more information for recognition is fine structure at high frequency other than the gross shapes of iris images. Therefore, we transform iris images into frequency domain and set different weights to frequencies. Then calculate the correlation of two iris images in frequency domain. We evaluate the iris images by summing the discrete correlation values with regulated weights, comparing the value with preset threshold to tell whether these two iris images are captured from the same person or not. Experiments are carried out on both CASIA database and self-obtained images. The results show that our method is functional and reliable. Our method provides a new prospect for iris recognition system.

  7. [The automatic iris map overlap technology in computer-aided iridiagnosis].

    Science.gov (United States)

    He, Jia-feng; Ye, Hu-nian; Ye, Miao-yuan

    2002-11-01

    In the paper, iridology and computer-aided iridiagnosis technologies are briefly introduced and the extraction method of the collarette contour is then investigated. The iris map can be overlapped on the original iris image based on collarette contour extraction. The research on collarette contour extraction and iris map overlap is of great importance to computer-aided iridiagnosis technologies.

  8. 76 FR 13402 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2011-03-11

    ... Information System (IRIS); Announcement of Availability of Literature Searches for IRIS Assessments AGENCY: Environmental Protection Agency. ACTION: Announcement of availability of literature searches for IRIS... the availability of literature searches for cobalt (CASRN 7440-48-4) and inorganic cobalt compounds...

  9. 77 FR 20817 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2012-04-06

    ... System (IRIS); Announcement of Availability of Literature Searches for IRIS Assessments AGENCY: Environmental Protection Agency. ACTION: Announcement of availability of literature searches for IRIS... the availability of literature searches for acetaldehyde (75-07-0) and 1,2,3-trimethlybenzene (526-73...

  10. 5-HT receptors as novel targets for optimizing pigmentary responses in dorsal skin melanophores of frog, Hoplobatrachus tigerinus

    Science.gov (United States)

    Ali, Sharique A; Salim, Saima; Sahni, Tarandeep; Peter, Jaya; Ali, Ayesha S

    2012-01-01

    BACKGROUND AND PURPOSE Biochemical identification of 5-HT has revealed similar projection patterns across vertebrates. In CNS, 5-HT regulates major physiological functions but its peripheral functions are still emerging. The pharmacology of 5-HT is mediated by a diverse range of receptors that trigger different responses. Interestingly, 5-HT receptors have been detected in pigment cells indicating their role in skin pigmentation. Hence, we investigated the role of this monoaminergic system in amphibian pigment cells, melanophores, to further our understanding of its role in pigmentation biology together with its evolutionary significance. EXPERIMENTAL APPROACH Pharmacological profiling of 5-HT receptors was achieved using potent/selective agonists and antagonists. In vitro responses of melanophores were examined by Mean Melanophores Size Index assay. The melanophores of lower vertebrates are highly sensitive to external stimuli. The immediate cellular responses to drugs were defined in terms of pigment translocation within the cells. KEY RESULTS 5-HT exerted strong concentration-dependent pigment dispersion at threshold dose of 1 × 10−6 g·mL−1. Specific 5-HT1 and 5-HT2 receptor agonists, sumatriptan and myristicin. also induced dose-dependent dispersion. Yohimbine and metergoline synergistically antagonized sumatriptan-mediated dispersion, whereas trazodone partially blocked myristicin-induced dispersion. Conversely, 5-HT3 and 5-HT4 receptor agonists, 1 (3 chlorophenyl) biguanide (1,3 CPB) and 5-methoxytryptamine (5-MT), caused a dose-dependent pigment aggregation. The aggregatory effect of 1,3 CPB was completely blocked by ondansetron, whereas L-lysine partially blocked the effect of 5-MT. CONCLUSIONS AND IMPLICATIONS The results suggest that 5-HT-induced physiological effects are mediated via distinct classes of receptors, which possibly participate in the modulation of pigmentary responses in amphibian. PMID:21880033

  11. Microarray Analysis of Iris Gene Expression in Mice with Mutations Influencing Pigmentation

    Science.gov (United States)

    Trantow, Colleen M.; Cuffy, Tryphena L.; Fingert, John H.; Kuehn, Markus H.

    2011-01-01

    Purpose. Several ocular diseases involve the iris, notably including oculocutaneous albinism, pigment dispersion syndrome, and exfoliation syndrome. To screen for candidate genes that may contribute to the pathogenesis of these diseases, genome-wide iris gene expression patterns were comparatively analyzed from mouse models of these conditions. Methods. Iris samples from albino mice with a Tyr mutation, pigment dispersion–prone mice with Tyrp1 and Gpnmb mutations, and mice resembling exfoliation syndrome with a Lyst mutation were compared with samples from wild-type mice. All mice were strain (C57BL/6J), age (60 days old), and sex (female) matched. Microarrays were used to compare transcriptional profiles, and differentially expressed transcripts were described by functional annotation clustering using DAVID Bioinformatics Resources. Quantitative real-time PCR was performed to validate a subset of identified changes. Results. Compared with wild-type C57BL/6J mice, each disease context exhibited a large number of statistically significant changes in gene expression, including 685 transcripts differentially expressed in albino irides, 403 in pigment dispersion–prone irides, and 460 in exfoliative-like irides. Conclusions. Functional annotation clusterings were particularly striking among the overrepresented genes, with albino and pigment dispersion–prone irides both exhibiting overall evidence of crystallin-mediated stress responses. Exfoliative-like irides from mice with a Lyst mutation showed overall evidence of involvement of genes that influence immune system processes, lytic vacuoles, and lysosomes. These findings have several biologically relevant implications, particularly with respect to secondary forms of glaucoma, and represent a useful resource as a hypothesis-generating dataset. PMID:20739468

  12. Myopathy associated with pigmentary degeneration of the retina and high protein content of cerebrospinal fluid Miopatia associada a degeneração pigmentar da retina e hiperproteinorraquia

    Directory of Open Access Journals (Sweden)

    José Antonio Levy

    1974-06-01

    Full Text Available The cases of two brothers suffering from a myopathy associated with pigmentary degeneration of the retina and increase of protein content of the cerebrospinal fluid are reported.Foram estudados dois pacientes, filhos de pais não consanguíneos, com quadro miopático, iniciado na segunda década da vida, com predomínio na musculatura das cinturas e da face. Em ambos os casos havia degeneração pigmentar da retina e aumento da taxa protéica no líquido cefalorraqueano.

  13. Fitting the IRI F2-profile function to measured profiles

    International Nuclear Information System (INIS)

    Reinisch, B.W.; Huang Xueqin

    1997-01-01

    Comparison with profile data from ionosondes shows that the IRI bottomside F2-profiles can be improved by using better B0 and B1 parameters. The best parameters (in a least-squares sense) can be easily calculated in a numerical procedure from measured profiles presented as a sum of Chebyshev polynomials. 7 refs, 5 figs, 1 tab

  14. Silicon Graphics' IRIS InSight: An SGML Success Story.

    Science.gov (United States)

    Glushko, Robert J.; Kershner, Ken

    1993-01-01

    Offers a case history of the development of the Silicon Graphics "IRIS InSight" system, a system for viewing on-line documentation using Standard Generalized Markup Language. Notes that SGML's explicit encoding of structure and separation of structure and presentation make possible structure-based search, alternative structural views of…

  15. Internal testing of pipe systems with IRIS inspection system

    International Nuclear Information System (INIS)

    1986-01-01

    The internal piping inspection system IRIS allows inside testing of pipes with an internal diameter of NW 70 as a minimum, and of any horizontal or vertical layout of the piping system. Visual testing is done by means of an integrated CCD video system with high resolution power. Technical data are given and examples of applications, in the German and English language. (DG) [de

  16. IRIS Toxicological Review of Methanol (Noncancer) (Interagency Science Discussion Draft)

    Science.gov (United States)

    On May 3, 2013, the Toxicological Review of Methanol (noncancer) (Revised External Review Draft) was posted for public review and comment. Subsequently, the draft Toxicological Review, Appendices, and draft IRIS Summary were reviewed internally by EPA and by other federal agenci...

  17. IRIS Toxicological Review of Methanol (External Review Draft, 2013)

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of methanol (non-cancer) that when finalized will appear on the Integrated Risk Information System (IRIS) database.

  18. IRIS project update: status of the design and licensing activities

    International Nuclear Information System (INIS)

    Petrovic, B.; Carelli, M.

    2004-01-01

    This paper presents an overview of the current status of the IRIS (International Reactor Innovative and Secure) project, focusing on the design and licensing activities. An update relative to the previous presentation at the 4th HND Conference is provided, highlighting some of the main accomplishments over the past two years. After successfully completing the conceptual design phase, IRIS is now finalizing the preliminary design as well. The pre-application licensing review with the U.S. NRC has been initiated in October of 2002. The safety-by-design approach and PRA-guided design open the possibility to aim for licensing not requiring off-site emergency response planning. Multiple single-unit and twin-unit site layouts have been developed within the ESP (Early Site Permit) program currently pursued by three U.S. power utilities. Desalination and district heating options have recently been added to the base design. Staggered construction schedules of multiple units may be applied to optimize cash-flow and minimize the required investment, making IRIS a financially attractive option, even for economies with limited investment capabilities. Because of its modularity, compatibility with smaller/medium grids, and enabling gradual build of new generating capacity matching the needs, IRIS has a large potential in the worldwide market.(author)

  19. Case Report: Bilateral iris, choroid, optic nerve colobomas and ...

    African Journals Online (AJOL)

    Background: Baraitser–Winter syndrome (BRWS) is a malformation syndrome, characterized by facial dysmorphism, ocular colobomata, pachygyria, and intellectual defects. Case report: A 3.5 year old female child with BRWS has bilateral congenital ptosis, microcornea, iris, choroid, and optic nerve coloboma, retinal ...

  20. Preface: The International Reference Ionosphere (IRI) at equatorial latitudes

    Science.gov (United States)

    Reinisch, Bodo; Bilitza, Dieter

    2017-07-01

    This issue of Advances in Space Research includes papers that report and discuss improvements of the International Reference Ionosphere (IRI). IRI is the international standard for the representation of the plasma in Earth's ionosphere and recognized as such by the Committee on Space Research (COSPAR), the International Union of Radio Science (URSI), the International Telecommunication Union (ITU), and the International Standardization Organization (ISO). As requested, particularly by COSPAR and URSI, IRI is an empirical model relying on most of the available and reliable ground and space observations of the ionosphere. As new data become available and as older data sources are fully exploited the IRI model undergoes improvement cycles to stay as close to the existing data record as possible. The latest episode of this process is documented in the papers included in this issue using data from the worldwide network of ionosondes, from a few of the incoherent scatter radars, from the Alouette and ISIS topside sounders, and from the Global Navigation Satellite Systems (GNSS). The focus of this issue is on the equatorial and low latitude region that is of special importance for ionospheric physics because it includes the largest densities and steep density gradients in the double hump latitudinal structure, the Equatorial Ionization Anomaly (EIA), which is characteristic for this region.

  1. In Vitro Antimicrobial Activity of Iris pseudacorus and Urtica dioica

    Directory of Open Access Journals (Sweden)

    Maryam Ramtin

    2014-03-01

    Full Text Available Background: In this study, the effects of antibacterial activity of Urtica dioica and Iris pseudacorus essential oils, native plant northern of Iran, were investigated for some selected bacteria. Material and Methods: The influence of essential oils was tested by the using of disk diffusion and micro-broth dilution methods against standard strains of the picked out bacteria. Gas Chromatography/Mass Spectroscopy (GC/MS analysis, bioactivity determination, Minimum inhibitory concentrations (MIC and minimum bactericidal concentration (MBC of essential oils were utilized for this goal. Results: This study showed that, Inhibition zone diameter varied from 11 to 19 mm and 9 to 17 mm for Urtica dioica and Iris pseudacorus respectively. In contrast, this figure fluctuated from 19 to 28 mm and 7 to 17 mm for gentamicin and ampicillin separately. By the application of micro-broth dilution technique, MICs for 1% essential oils were 1.8-7.5 μg/ml and 3.75-15 μg/ml for, Urtica dioica and Iris pseudacorus against gram-positive and gram-negative bacteria individually. Furthermore, the MBCs of herbal essences were 1.8-15 μg/ml for, Urtica dioica and 15-30 μg/ml for Iris. Conclusion: The application of essential oils for the bio-control of diseases, as a novel emerging alternative to antimicrobial treatments, lead to safer and more environmental management for infective diseases4T.4T

  2. IRIS Toxicological Review of Thallium and Compounds (Final Report)

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Thallium and Compounds: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health.

  3. A Field Study of an Iris Identification System

    Science.gov (United States)

    2008-05-01

    conducted a field trial of a commercial iris identification scanner at the US Navy Fleet Numerical Meterology and Oceanography Center (FNMOC) in...identification scanner at the US Navy Fleet Numerical Meterology and Oceanography Center (FNMOC) in Mon- terey, CA. Scans were performed by US military guards

  4. Intraocular lens iris fixation. Clinical and macular OCT outcomes

    Science.gov (United States)

    2012-01-01

    Background To assess the efficacy, clinical outcomes, visual acuity (VA), incidence of adverse effects, and complications of peripheral iris fixation of 3-piece acrylic IOLs in eyes lacking capsular support. Thirteen patients who underwent implantation and peripheral iris fixation of a 3-piece foldable acrylic PC IOL for aphakia in the absence of capsular support were followed after surgery. Clinical outcomes and macular SD-OCT (Cirrus OCT; Carl Zeiss Meditec, Germany) were analyzed. Findings The final CDVA was 20/40 or better in 8 eyes (62%), 20/60 or better in 12 eyes (92%), and one case of 20/80 due to corneal astigmatism and mild persistent edema. No intraoperative complications were reported. There were seven cases of medically controlled ocular hypertension after surgery due to the presence of viscoelastic in the AC. There were no cases of cystoid macular edema, chronic iridocyclitis, IOL subluxation, pigment dispersion, or glaucoma. Macular edema did not develop in any case by means of SD-OCT. Conclusions We think that this technique for iris suture fixation provides safe and effective results. Patients had substantial improvements in UDVA and CDVA. This surgical strategy may be individualized however; age, cornea status, angle structures, iris anatomy, and glaucoma are important considerations in selecting candidates for an appropriate IOL fixation method. PMID:23050659

  5. Intraocular lens iris fixation. Clinical and macular OCT outcomes

    Directory of Open Access Journals (Sweden)

    Garcia-Rojas Leonardo

    2012-10-01

    Full Text Available Abstract Background To assess the efficacy, clinical outcomes, visual acuity (VA, incidence of adverse effects, and complications of peripheral iris fixation of 3-piece acrylic IOLs in eyes lacking capsular support. Thirteen patients who underwent implantation and peripheral iris fixation of a 3-piece foldable acrylic PC IOL for aphakia in the absence of capsular support were followed after surgery. Clinical outcomes and macular SD-OCT (Cirrus OCT; Carl Zeiss Meditec, Germany were analyzed. Findings The final CDVA was 20/40 or better in 8 eyes (62%, 20/60 or better in 12 eyes (92%, and one case of 20/80 due to corneal astigmatism and mild persistent edema. No intraoperative complications were reported. There were seven cases of medically controlled ocular hypertension after surgery due to the presence of viscoelastic in the AC. There were no cases of cystoid macular edema, chronic iridocyclitis, IOL subluxation, pigment dispersion, or glaucoma. Macular edema did not develop in any case by means of SD-OCT. Conclusions We think that this technique for iris suture fixation provides safe and effective results. Patients had substantial improvements in UDVA and CDVA. This surgical strategy may be individualized however; age, cornea status, angle structures, iris anatomy, and glaucoma are important considerations in selecting candidates for an appropriate IOL fixation method.

  6. IRIS Toxicological Review of Hexabromocyclododecane (HBCD) (Preliminary Assessment Materials)

    Science.gov (United States)

    In March 2014, EPA released the draft literature searches and associated search strategies, evidence tables, and exposure response arrays for HBCD to obtain input from stakeholders and the public prior to developing the draft IRIS assessment. Specifically, EPA was interested in c...

  7. Iris metastasis in small-cell lung carcinoma

    NARCIS (Netherlands)

    Roenhorst, Anke W. J.; van den Bergh, Alphons C. M.; van Putten, John W. G.; Smit, Egbert F.

    2007-01-01

    Small-cell lung cancer (SCLC) is characterized by rapid growth and early metastasis. Despite its sensitivity to cytotoxic treatment, until now treatments have failed to control or cure this disease in most patients. Here, we describe a patient with SCLC in which symptoms caused by iris metastasis

  8. Three-batch reloading scheme for IRIS reactor extended cycles

    International Nuclear Information System (INIS)

    Jecmenica, R.; Pevec, D.; Grgic, D.

    2004-01-01

    To fully exploit the IRIS reactor optimized maintenance, and at the same time improve fuel utilization, a core design enabling a 4-year operating cycle together with a three-batch reloading scheme is desirable. However, this requires not only the increased allowed burnup but also use of fuel with uranium oxide enriched beyond 5%. This paper considers three-batch reloading scheme for a 4-year operating cycle with the assumptions of increased discharge burnup and fuel enrichment beyond 5%. Calculational model of IRIS reactor core has been developed based on FER FA2D code for group constants generation and NRC's PARCS nodal code for global core analysis. Studies have been performed resulting in a preliminary design of a three-batch core configuration for the first cycle. It must be emphasized that this study is outside the current IRIS licensing efforts, which rely on the present fuel technology (enrichment below 5%), but it is of long-term interest for potential future IRIS design upgrades. (author)

  9. Delay of Iris flower senescence by protease inhibitors

    NARCIS (Netherlands)

    Pak, C.; Doorn, van W.G.

    2005-01-01

    asterisk inside a circle sign Visible senescence of the flag tepals in Iris x hollandica (cv. Blue Magic) was preceded by a large increase in endoprotease activity. Just before visible senescence about half of total endoprotease activity was apparently due to cysteine proteases, somewhat less than

  10. Outcomes Associated With Concurrent Iris-Sutured Intraocular Lens Placement and Subluxated Crystalline Lens Extraction.

    Science.gov (United States)

    McClellan, Scott F; Soiberman, Uri; Gehlbach, Peter L; Murakami, Peter N; Stark, Walter J

    2015-08-01

    We have developed a novel surgical technique, to our knowledge, for the management of subluxated crystalline lenses involving preplacement of an iris-sutured posterior chamber intraocular lens (PCIOL) before pars plana vitrectomy and lensectomy. To investigate the outcomes of eyes with subluxated crystalline lenses, predominantly a result of Marfan syndrome (14 eyes [58%]) or trauma (5 eyes [21%]), that underwent pars plana vitrectomy and lensectomy with placement of an iris-sutured PCIOL. We performed a retrospective, noncomparative case series of 24 eyes from 17 consecutive adult patients with surgically treated subluxated crystalline lenses presenting to the Wilmer Eye Institute at Johns Hopkins Hospital from October 6, 2006, through May 1, 2013. The mean (SD) postoperative follow-up was 24.4 (20.5) months for eyes with at least 6 months of follow-up (last date, October 13, 2014). We performed the analysis from January 21, 2014, through January 3, 2015. Improvement in best-corrected visual acuity using an automated Snellen chart and induction of astigmatism for eyes with at least 6 months of follow-up (n = 18) and IOL stability during follow-up for all eyes (n = 24). The mean (SD) age at surgery was 49.4 (10.7 [range, 29-67]) years. We found an improvement in mean (SD [95% CI]) best-corrected visual acuity from 0.66 (0.71 [0.30-1.02]) logMAR preoperatively (Snellen equivalent, approximately 20/90; range, 20/30 to hand motions) to 0.07 (0.11 [95% CI, 0.01-0.12]) logMAR postoperatively (Snellen equivalent, approximately 20/23; range, 20/15 to 20/50). We found little change in astigmatism postoperatively (mean change, -0.1 [95% CI, -0.5 to 0.13] diopters). Postoperative complications included retinal detachment (1 eye [4%]), retained cortical fragment (1 [4%]), cystoid macular edema (2 [8%]), and IOL subluxation (3 [13%]) owing to haptic slippage within 3 months of the procedure. The overall probability of successfully achieving placement of a centered iris

  11. IRIS International Reactor Innovative and Secure Final Technical Progress Report

    International Nuclear Information System (INIS)

    Carelli, M.D.

    2003-01-01

    OAK-B135 This NERI project, originally started as the Secure Transportable Autonomous Light Water Reactor (STAR-LW) and currently known as the International Reactor Innovative and Secure (IRIS) project, had the objective of investigating a novel type of water-cooled reactor to satisfy the Generation IV goals: fuel cycle sustainability, enhanced reliability and safety, and improved economics. The research objectives over the three-year (1999-2002) program were as follows: First year: Assess various design alternatives and establish main characteristics of a point design; Second year: Perform feasibility and engineering assessment of the selected design solutions; Third year: Complete reactor design and performance evaluation, including cost assessment These objectives were fully attained and actually they served to launch IRIS as a full fledged project for eventual commercial deployment. The program did not terminate in 2002 at the end of the NERI program, and has just entered in its fifth year. This has been made possible by the IRIS project participants which have grown from the original four member, two-countries team to the current twenty members, nine countries consortium. All the consortium members work under their own funding and it is estimated that the value of their in-kind contributions over the life of the project has been of the order of $30M. Currently, approximately 100 people worldwide are involved in the project. A very important constituency of the IRIS project is the academia: 7 universities from four countries are members of the consortium and five more US universities are associated via parallel NERI programs. To date, 97 students have worked or are working on IRIS; 59 IRIS-related graduate theses have been prepared or are in preparation, and 41 of these students have already graduated with M.S. (33) or Ph.D. (8) degrees. This ''final'' report (final only as far as the NERI program is concerned) summarizes the work performed in the first four

  12. Comparison of anterior segment optical coherence tomography angiography and fluorescein angiography for iris vasculature analysis.

    Science.gov (United States)

    Zett, Claudio; Stina, Deborah M Rosa; Kato, Renata Tiemi; Novais, Eduardo Amorim; Allemann, Norma

    2018-04-01

    The aim of this study is to perform imaging of irises of different colors using spectral domain anterior segment optical coherence tomography angiography (AS-OCTA) and iris fluorescein angiography (IFA) and compare their effectiveness in examining iris vasculature. This is a cross-sectional observational clinical study. Patients with no vascular iris alterations and different pigmentation levels were recruited. Participants were imaged using OCTA adapted with an anterior segment lens and IFA with a confocal scanning laser ophthalmoscope (cSLO) adapted with an anterior segment lens. AS-OCTA and IFA images were then compared. Two blinded readers classified iris pigmentation and compared the percentage of visible vessels between OCTA and IFA images. Twenty eyes of 10 patients with different degrees of iris pigmentation were imaged using AS-OCTA and IFA. Significantly more visible iris vessels were observed using OCTA than using FA (W = 5.22; p Iris pigmentation was negatively correlated to the percentage of visible vessels in both imaging methods (OCTA, rho = - 0.73, p iris vasculature. In both AS-OCTA and IFA, iris pigmentation caused vasculature imaging blockage, but AS-OCTA provided more detailed iris vasculature images than IFA. Additional studies including different iris pathologies are needed to determine the most optimal scanning parameters in OCTA of the anterior segment.

  13. Treatment of non-resectable malignant iris tumours with custom designed plaque radiotherapy

    International Nuclear Information System (INIS)

    Shields, C.L.; Shields, J.A.; Potter, P. De; Singh, A.D.; Hernandez, C.; Brady, L.W.

    1995-01-01

    Background- Plaque radiotherapy is the most common method of managing posterior uveal melanoma but its use for iris melanoma and iris metastases has not yet been evaluated. Methods -Fourteen patients with non-resectable iris melanoma and four with iris metastasis were treated with plaque radiotherapy. The tumour response to treatment and the local side effects of the radioactive plaque were evaluated. Results -In the iris melanoma group over a mean follow up of 26 (range 6-75) months, the tumour regressed in 13 of the 14 patients (93%) and recurred as diffuse seeding in one patient (7%). Despite large doses of radiation given transcorneally, the cornea developed epitheliopathy, abraxion, and oedema in only one case each. The major radiation side effects were localised iris vasculopathy without glaucoma in two cases, posterior synechiae in five cases, and cataract in six cases. In the iris metastasis group, tumour regression was observed in all four patients (100%) and radiation side effects were not evident over the relatively short mean follow up period of 8 (range 4-9) months. All of the 14 patients with irradiated iris melanoma have remained systemically healthy without metastasis while three of the four patients with irradiated iris metastases have died of metastases from the primary neoplasm. Conclusion - Custom designed plaque radiotherapy appears to be an effective alternative method of controlling non-resectable diffuse iris melanoma and solitary iris metastasis and has relatively few side effects. (author)

  14. The Future of Seismic Data Quality Assurance at the IRIS DMC

    Science.gov (United States)

    Templeton, M. E.; Sharer, G.; Ashmore, S.; Casey, R. E.; Ahern, T. K.

    2014-12-01

    The IRIS Data Management Center (DMC) hosts a large and ever-growing archive of data from seismic stations around the world. One of the challenges in maintaining this archive is the need for providing Quality Assurance (QA) on its contents so that the data can be most effectively used by the scientific community. In the past, IRIS has focussed its QA efforts on improving data quality for a targeted subset of seismic networks, most notably the Earthscope USArray Transportable Array and the Global Seismic Network (GSN). Now with the rollout of MUSTANG, the DMC's new automated data quality metrics system, we are embarking on an ambitious effort to bring QA to the entirety of the DMC seismic data archive. Analysts at the DMC are in the process of developing improved techniques to find data problems, document significant issues, and communicate our results. Our initial efforts are directed at creating a prototype of a scalable QA process using GSN data and MUSTANG metrics. We will show how MUSTANG metrics, both as single measurements and aggregates of multiple measurements, can be used to quickly flag potential problems and demonstrate how analysts can use visualization tools to track changes in data quality at stations and across networks. Communication between IRIS, network operators, and data users will be crucial to the success of any QA effort. To that end, we are also improving our web presence with the aim of increasing data quality awareness within the seismological community and providing a place where people can report issues they encounter with either data or metrics measurements.

  15. Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow.

    Science.gov (United States)

    Repetto, Rodolfo; Pralits, Jan O; Siggers, Jennifer H; Soleri, Paolo

    2015-05-01

    Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.

  16. Iris Segmentation using Gradient Magnitude and Fourier Descriptor for Multimodal Biometric Authentication System

    Directory of Open Access Journals (Sweden)

    Defiana Sulaeman

    2016-12-01

    Full Text Available Perfectly segmenting the area of the iris is one of the most important steps in iris recognition. There are several problematic areas that affect the accuracy of the iris segmentation step, such as eyelids, eyelashes, glasses, pupil (due to less accurate iris segmentation, motion blur, and lighting and specular reflections. To solve these problems, gradient magnitude and Fourier descriptor are employed to do iris segmentation in the proposed Multimodal Biometric Authentication System (MBAS. This approach showed quite promising results, i.e. an accuracy rate of 97%. The result of the iris recognition system was combined with the result of an open-source fingerprint recognition system to develop a multimodal biometrics authentication system. The results of the fusion between iris and fingerprint authentication were 99% accurate. Data from Multimedia Malaysia University (MMUI and our own prepared database, the SGU-MB-1 dataset, were used to test the accuracy of the proposed system.

  17. Security enhanced BioEncoding for protecting iris codes

    Science.gov (United States)

    Ouda, Osama; Tsumura, Norimichi; Nakaguchi, Toshiya

    2011-06-01

    Improving the security of biometric template protection techniques is a key prerequisite for the widespread deployment of biometric technologies. BioEncoding is a recently proposed template protection scheme, based on the concept of cancelable biometrics, for protecting biometric templates represented as binary strings such as iris codes. The main advantage of BioEncoding over other template protection schemes is that it does not require user-specific keys and/or tokens during verification. Besides, it satisfies all the requirements of the cancelable biometrics construct without deteriorating the matching accuracy. However, although it has been shown that BioEncoding is secure enough against simple brute-force search attacks, the security of BioEncoded templates against more smart attacks, such as record multiplicity attacks, has not been sufficiently investigated. In this paper, a rigorous security analysis of BioEncoding is presented. Firstly, resistance of BioEncoded templates against brute-force attacks is revisited thoroughly. Secondly, we show that although the cancelable transformation employed in BioEncoding might be non-invertible for a single protected template, the original iris code could be inverted by correlating several templates used in different applications but created from the same iris. Accordingly, we propose an important modification to the BioEncoding transformation process in order to hinder attackers from exploiting this type of attacks. The effectiveness of adopting the suggested modification is validated and its impact on the matching accuracy is investigated empirically using CASIA-IrisV3-Interval dataset. Experimental results confirm the efficacy of the proposed approach and show that it preserves the matching accuracy of the unprotected iris recognition system.

  18. Alpha antagonists and intraoperative floppy iris syndrome: A spectrum

    Directory of Open Access Journals (Sweden)

    Sharif A Issa

    2008-07-01

    Full Text Available Sharif A Issa, Omar H Hadid, Oliver Baylis, Margaret DayanDepartment of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne, UKBackground: To determine occurrence of features of intraoperative floppy iris syndrome (IFIS during cataract surgery in patients taking systemic alpha-antagonists (AA.Methods: We prospectively studied patients on AA and who underwent phacoemulsification. The following were recorded: pupil diameter preoperatively, iris flaccidity, iris prolapse and peroperative miosis.Results: We studied 40 eyes of 31 subjects. Mean age was 78 years. Overall, 14 eyes (13 patients showed signs of IFIS: 9/13 (69% eyes of patients on tamsulosin, 1/18 (6% eyes in the doxazosin group, 2/2 prazosin patients, 1/4 eyes in the indoramin group, and 1/2 eyes in two patients on a combination of doxazosin and tamsulosin. Most cases (92% had only one or two signs of IFIS. Bilateral cataract surgery was undertaken in 9 patients but only one patient (on tamsulosin had features of IFIS in both eyes, while 4 patients (2 on tamsulosin and 2 on other AA showed signs of IFIS in one eye only, and 4 patients did not show IFIS in either eye.Conclusion: Most AA were associated with IFIS, but it tends to present as a spectrum of signs rather than full triad originally described. Tamsulosin was most likely to be associated with IFIS; however, its intake does not necessarily mean that IFIS will occur. For patients on AA, the behavior of the iris intraoperatively in one eye is a poor predictor of the other eye. Surgeons should anticipate the occurrence of IFIS in any patient on AA.Keywords: alpha blocker, alpha antagonist, cataract surgery, intraoperative floppy iris syndrome, tamsulosin.

  19. Astaxanthin from Crayfish (Procambarus clarkii as a Pigmentary Ingredient in the Feed of Laying Hens

    Directory of Open Access Journals (Sweden)

    Garrido-Fernández, J.

    2008-06-01

    Full Text Available Chicken egg yolks generally owe their color to yellow carotenoids. The addition of synthetic red pigments allows changes in color, from the original yellow to red hues which may be more appealing to consumers in certain markets.Our aim has been to test whether ground crayfish shells, which are a rich and natural source of astaxanthin, produce detectable changes in the coloration of egg yolks through the accumulation of this carotenoid. Laying hens were fed with a commercial feed mixed with crayfish powder and the carotenoid profiles of the yolks in the eggs laid during the trial were monitored by HPLC. The analyses showed a progressive increase in the astaxanthin concentration in the egg yolks, reaching similar levels to those obtained for the rest of present carotenoid pigments.La yema de huevo de gallina debe su coloración a la presencia de carotenoides de tonalidad amarilla. La adición de colorantes sintéticos de tonalidades rojas permite modificar e incrementar la coloración de la yema desde el amarillo original a tonos rojos que pueden ser demandados en ciertos mercados según las preferencias del consumidor. El objetivo del trabajo fue probar si un triturado obtenido a partir de caparazones de cangrejo, que es una fuente natural y rica en astaxanteno, produce cambios detectables en la coloración de la yema de huevo por la acumulación de dicho carotenoide. Las gallinas ponedoras se alimentaron con un pienso comercial al que se adicionó triturado de caparazón de cangrejo. Se realizó un seguimiento de los cambios en la composición carotenoide (mediante HPLC de la yema de los huevos puestos durante el periodo de alimentación suplementada. Los análisis mostraron una progresiva incorporación de astaxanteno que alcanzó niveles similares al resto de carotenoides presentes inicialmente en la yema.

  20. Twenty-one year old female with an iris tumor: a case report

    International Nuclear Information System (INIS)

    Zettinig, G.; Kurtaran, A.; Dudczak, R.; Maca, S.; Barisani, T.; Horvat, R.

    2002-01-01

    Full text: A 21-year-old female with multiple granulomas an the right iris with concomitant therapy refractive panuveitis was referred to the Department of Ophthalmology to exclude an ocular malignancy. The patient had a history of minimal change glomerulonephritis and cutaneous granulomas at the age of six years that were successfully treated with cyclophosphamide. Her visual acuity initially already reduced to 30 % decreased rapidly to 'counting fingers'. A clinical work-up including chest x-ray, spiral computed tomography of the lungs and a detailed serological examination including angiotensin converting enzyme showed no evidence of infection or neoplasia. Planar scintigraphy 24 hours after administration of 185 MBq Gallium-67 citrate demonstrated an intense tracer accumulation in both lacrimal glands. Salivary gland uptake was normal and there was only a faint accumulation in the mediastinum interpreted as normal. A biopsy of the right iris revealed a granulomatous non caseating inflammation diagnosed as sarcoidosis. A systemic combination treatment with prednisolone and methotrexate for 4 months could not control the inflammation. After therapy was changed to cyclosporine the inflammation decreased and visual acuity decreased to 60 %. Neither a 'lambda sign' (characteristic uptake of Ga-67 in intrathoracic lymph nodes resembling the Greek letter lambda) nor a typical 'panda sign' (bilateral salivary and lacrimal gland uptake of Ga-67) commonly present in sarcoidosis were seen in our patient. This case demonstrates that in individual patients with sarcoidosis, lacrimal gland uptake of Ga-67 may be the only significant noninvasive finding. (author)

  1. Adjunctive cryotherapy for pigmentary keratitis in dogs: a study of 16 corneas.

    Science.gov (United States)

    Azoulay, Thierry

    2014-07-01

    To assess whether soft cryotherapy (dimethylether, isobutene, and propane) can remove pigmentation of the cornea that has accumulated under different conditions when conventional therapy has been unsuccessful. Nine dogs with unilateral or bilateral corneal pigmentation (16 eyes) were included based on progressive corneal pigmentation that was unresponsive to long-term etiological treatment. The dogs had keratoconjunctivitis sicca or chronic superficial keratitis. A cryogen of 95% dimethylether, 3% isobutane, and 2% propane was applied to the pigmented areas of each cornea under anesthesia. Initial corneal pigmentation and changes were documented over the entire study period using a grading scheme and clinical photographs. Most of the pigment deposits were gone by 5-15 days after cryosurgery. Postoperatively, the dogs showed some corneal edema and corneo-conjunctival inflammation, and three dogs had superficial corneal ulcers; these symptoms had resolved by 1 month after the procedure. Follow-up for more than 90 days was available in five dogs (nine corneas), and we observed total or partial repigmentation when the underlying disease was not controlled. A new cryotherapy procedure was successfully performed in two of these dogs. Given the sensitivity to cold of melanocytes, cryotherapy is a viable adjunctive treatment for refractory severe corneal pigmentation. Etiological treatment remains necessary to prevent pigmentation from rapidly reappearing. Only a few dogs were followed for more than 90 days; further study is necessary to evaluate the long-term safety and efficacy of soft cryotherapy. © 2013 American College of Veterinary Ophthalmologists.

  2. El dibujo libre en el niño con Retinosis Pigmentaria Free drawing in children with Pigmentary Retinosis

    Directory of Open Access Journals (Sweden)

    Irene Sofía Quiñones Varela

    2005-12-01

    Full Text Available Se realizó un estudio observacional descriptivo en el Centro Provincial de Retinosis Pigmentaria con el objetivo de describir las características del dibujo libre en el niño con Retinosis Pigmentaria. El universo estuvo constituido por los pacientes en etapa escolar y adolescencia temprana con esta enfermedad. La muestra intencional fue de 41 pacientes. En los dibujos realizados se apreció un predominio del uso de 3 a 6 colores con la combinación de colores cálidos sin relleno en la figura, prevalecieron las combinaciones realistas, al igual que el trazado fuerte e inestable con combinación de trazado fuerte y débil. Se apreció coherencia y originalidad en los dibujos. Predominó el paisaje campestre. Los colores más representados en los dibujos fueron rojo, amarillo y azul. Entre los hallazgos más importantes se encuentra que en cuanto a la forma los dibujos tienen puntos de contacto con los de los niños con patologías que expresan inmadurez en la coordinación viso-motora. El tema de los dibujos se corresponde con lo encontrado por otros autores con respecto al dibujo del niño cubanoA descriptive observational study was carried out in the Provincial Center of Retinosis with the objective of describing the characteristic of the free drawing in children with pigmentary retinosis. This group was constituted by the patients in school stage and in early adolescence with this illness. The intentional sample belonged to 41 patients. It was appreciated predominant use of 3 or 6 colours in the drawings they carried out as well as the combination of warm colours without refilling in the figure, the realistic combinations prevailed, the same as the strong and unstable traced with combination of strong and weak traced. It was appreciated coherence and originality in the drawings. The country landscape prevailed. The colours more represented in drawings were red, yellow and blue. Among the most important discoveries are the drawings taking

  3. Exfoliation syndrome and exfoliation glaucoma-associated LOXL1 variations are not involved in pigment dispersion syndrome and pigmentary glaucoma.

    Science.gov (United States)

    Rao, Kollu Nageswara; Ritch, Robert; Dorairaj, Syril K; Kaur, Inderjeet; Liebmann, Jeffrey M; Thomas, Ravi; Chakrabarti, Subhabrata

    2008-07-09

    Single nucleotide polymorphisms (SNPs) in the LOXL1 gene have been implicated in exfoliation syndrome (XFS) and exfoliation glaucoma (XFG). We have shown that these SNPs are not associated with the primary glaucomas such as primary open-angle (POAG) glaucoma and primary angle-closure glaucoma (PACG). To further establish the specificity of LOXL1 SNPs for XFS and XFG, we determined whether these SNPs were involved in pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG). Three SNPs of LOXL1 (rs1048661, rs3825942, and rs2165241) were screened in a cohort of 78 unrelated and clinically well characterized glaucoma cases comprising of PG (n=44) and PDS (n=34) patients as well as 108 ethnically matched normal controls of Caucasian origin. The criteria for diagnosis of PDS/PG were Krukenberg spindle, hyperpigmentation of the trabecular meshwork, and wide open angle. Transillumination defects were detected by infrared pupillography, and the presence of a Zentmayer ring was considered as a confirmatory sign. All three SNPs were genotyped in cases and controls by resequencing the genomic region of LOXL1 harboring these variants and were further confirmed by polymerase chain reaction (PCR)-based restriction digestions. Haplotypes were generated from the genotype data, and the linkage disequilibrium (LD) and haplotype analysis were done with Haploview software that uses the expectation maximization (EM) algorithm. The LOXL1 SNPs showed no significant association with PDS or PG. There was no significant difference in the frequencies of the risk alleles of rs1048661 ('G' allele; p=0.309), rs3825942 ('G' allele' p=0.461), and rs2165241 ('T' allele; p=0.432) between PG/PDS cases and controls. Similarly, there was no involvement of the XFS/XFG-associated haplotypes, 'G-G' (p=0.643; [OR=1.08, 95%CI, 0.59-1.97]) and 'T-G' (p=0.266; [OR=1.35, 95%CI, 0.70-2.60]), with the PDS/PG phenotypes. The risk haplotype 'G-G' was observed in ~55% of the normal controls. There was no

  4. IrisDenseNet: Robust Iris Segmentation Using Densely Connected Fully Convolutional Networks in the Images by Visible Light and Near-Infrared Light Camera Sensors.

    Science.gov (United States)

    Arsalan, Muhammad; Naqvi, Rizwan Ali; Kim, Dong Seop; Nguyen, Phong Ha; Owais, Muhammad; Park, Kang Ryoung

    2018-05-10

    The recent advancements in computer vision have opened new horizons for deploying biometric recognition algorithms in mobile and handheld devices. Similarly, iris recognition is now much needed in unconstraint scenarios with accuracy. These environments make the acquired iris image exhibit occlusion, low resolution, blur, unusual glint, ghost effect, and off-angles. The prevailing segmentation algorithms cannot cope with these constraints. In addition, owing to the unavailability of near-infrared (NIR) light, iris recognition in visible light environment makes the iris segmentation challenging with the noise of visible light. Deep learning with convolutional neural networks (CNN) has brought a considerable breakthrough in various applications. To address the iris segmentation issues in challenging situations by visible light and near-infrared light camera sensors, this paper proposes a densely connected fully convolutional network (IrisDenseNet), which can determine the true iris boundary even with inferior-quality images by using better information gradient flow between the dense blocks. In the experiments conducted, five datasets of visible light and NIR environments were used. For visible light environment, noisy iris challenge evaluation part-II (NICE-II selected from UBIRIS.v2 database) and mobile iris challenge evaluation (MICHE-I) datasets were used. For NIR environment, the institute of automation, Chinese academy of sciences (CASIA) v4.0 interval, CASIA v4.0 distance, and IIT Delhi v1.0 iris datasets were used. Experimental results showed the optimal segmentation of the proposed IrisDenseNet and its excellent performance over existing algorithms for all five datasets.

  5. IrisDenseNet: Robust Iris Segmentation Using Densely Connected Fully Convolutional Networks in the Images by Visible Light and Near-Infrared Light Camera Sensors

    Directory of Open Access Journals (Sweden)

    Muhammad Arsalan

    2018-05-01

    Full Text Available The recent advancements in computer vision have opened new horizons for deploying biometric recognition algorithms in mobile and handheld devices. Similarly, iris recognition is now much needed in unconstraint scenarios with accuracy. These environments make the acquired iris image exhibit occlusion, low resolution, blur, unusual glint, ghost effect, and off-angles. The prevailing segmentation algorithms cannot cope with these constraints. In addition, owing to the unavailability of near-infrared (NIR light, iris recognition in visible light environment makes the iris segmentation challenging with the noise of visible light. Deep learning with convolutional neural networks (CNN has brought a considerable breakthrough in various applications. To address the iris segmentation issues in challenging situations by visible light and near-infrared light camera sensors, this paper proposes a densely connected fully convolutional network (IrisDenseNet, which can determine the true iris boundary even with inferior-quality images by using better information gradient flow between the dense blocks. In the experiments conducted, five datasets of visible light and NIR environments were used. For visible light environment, noisy iris challenge evaluation part-II (NICE-II selected from UBIRIS.v2 database and mobile iris challenge evaluation (MICHE-I datasets were used. For NIR environment, the institute of automation, Chinese academy of sciences (CASIA v4.0 interval, CASIA v4.0 distance, and IIT Delhi v1.0 iris datasets were used. Experimental results showed the optimal segmentation of the proposed IrisDenseNet and its excellent performance over existing algorithms for all five datasets.

  6. Iris recognition and what is next? Iris diagnosis: a new challenging topic for machine vision from image acquisition to image interpretation

    Science.gov (United States)

    Perner, Petra

    2017-03-01

    Molecular image-based techniques are widely used in medicine to detect specific diseases. Look diagnosis is an important issue but also the analysis of the eye plays an important role in order to detect specific diseases. These topics are important topics in medicine and the standardization of these topics by an automatic system can be a new challenging field for machine vision. Compared to iris recognition has the iris diagnosis much more higher demands for the image acquisition and interpretation of the iris. One understands by iris diagnosis (Iridology) the investigation and analysis of the colored part of the eye, the iris, to discover factors, which play an important role for the prevention and treatment of illnesses, but also for the preservation of an optimum health. An automatic system would pave the way for a much wider use of the iris diagnosis for the diagnosis of illnesses and for the purpose of individual health protection. With this paper, we describe our work towards an automatic iris diagnosis system. We describe the image acquisition and the problems with it. Different ways are explained for image acquisition and image preprocessing. We describe the image analysis method for the detection of the iris. The meta-model for image interpretation is given. Based on this model we show the many tasks for image analysis that range from different image-object feature analysis, spatial image analysis to color image analysis. Our first results for the recognition of the iris are given. We describe how detecting the pupil and not wanted lamp spots. We explain how to recognize orange blue spots in the iris and match them against the topological map of the iris. Finally, we give an outlook for further work.

  7. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor

    Science.gov (United States)

    Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung

    2018-01-01

    Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies. PMID:29695113

  8. Iris Location Algorithm Based on the CANNY Operator and Gradient Hough Transform

    Science.gov (United States)

    Zhong, L. H.; Meng, K.; Wang, Y.; Dai, Z. Q.; Li, S.

    2017-12-01

    In the iris recognition system, the accuracy of the localization of the inner and outer edges of the iris directly affects the performance of the recognition system, so iris localization has important research meaning. Our iris data contain eyelid, eyelashes, light spot and other noise, even the gray transformation of the images is not obvious, so the general methods of iris location are unable to realize the iris location. The method of the iris location based on Canny operator and gradient Hough transform is proposed. Firstly, the images are pre-processed; then, calculating the gradient information of images, the inner and outer edges of iris are coarse positioned using Canny operator; finally, according to the gradient Hough transform to realize precise localization of the inner and outer edge of iris. The experimental results show that our algorithm can achieve the localization of the inner and outer edges of the iris well, and the algorithm has strong anti-interference ability, can greatly reduce the location time and has higher accuracy and stability.

  9. Improving iris recognition performance using segmentation, quality enhancement, match score fusion, and indexing.

    Science.gov (United States)

    Vatsa, Mayank; Singh, Richa; Noore, Afzel

    2008-08-01

    This paper proposes algorithms for iris segmentation, quality enhancement, match score fusion, and indexing to improve both the accuracy and the speed of iris recognition. A curve evolution approach is proposed to effectively segment a nonideal iris image using the modified Mumford-Shah functional. Different enhancement algorithms are concurrently applied on the segmented iris image to produce multiple enhanced versions of the iris image. A support-vector-machine-based learning algorithm selects locally enhanced regions from each globally enhanced image and combines these good-quality regions to create a single high-quality iris image. Two distinct features are extracted from the high-quality iris image. The global textural feature is extracted using the 1-D log polar Gabor transform, and the local topological feature is extracted using Euler numbers. An intelligent fusion algorithm combines the textural and topological matching scores to further improve the iris recognition performance and reduce the false rejection rate, whereas an indexing algorithm enables fast and accurate iris identification. The verification and identification performance of the proposed algorithms is validated and compared with other algorithms using the CASIA Version 3, ICE 2005, and UBIRIS iris databases.

  10. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor

    Directory of Open Access Journals (Sweden)

    Dat Tien Nguyen

    2018-04-01

    Full Text Available Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD method for an iris recognition system (iPAD using a near infrared light (NIR camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED. Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM. Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies.

  11. Novel approaches to improve iris recognition system performance based on local quality evaluation and feature fusion.

    Science.gov (United States)

    Chen, Ying; Liu, Yuanning; Zhu, Xiaodong; Chen, Huiling; He, Fei; Pang, Yutong

    2014-01-01

    For building a new iris template, this paper proposes a strategy to fuse different portions of iris based on machine learning method to evaluate local quality of iris. There are three novelties compared to previous work. Firstly, the normalized segmented iris is divided into multitracks and then each track is estimated individually to analyze the recognition accuracy rate (RAR). Secondly, six local quality evaluation parameters are adopted to analyze texture information of each track. Besides, particle swarm optimization (PSO) is employed to get the weights of these evaluation parameters and corresponding weighted coefficients of different tracks. Finally, all tracks' information is fused according to the weights of different tracks. The experimental results based on subsets of three public and one private iris image databases demonstrate three contributions of this paper. (1) Our experimental results prove that partial iris image cannot completely replace the entire iris image for iris recognition system in several ways. (2) The proposed quality evaluation algorithm is a self-adaptive algorithm, and it can automatically optimize the parameters according to iris image samples' own characteristics. (3) Our feature information fusion strategy can effectively improve the performance of iris recognition system.

  12. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor.

    Science.gov (United States)

    Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung

    2018-04-24

    Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies.

  13. Iris and periocular adverse reactions to bimatoprost in Japanese patients with glaucoma or ocular hypertension

    Directory of Open Access Journals (Sweden)

    Inoue K

    2012-01-01

    Full Text Available Kenji Inoue1, Minako Shiokawa1, Michitaka Sugahara1, Risako Higa1, Masato Wakakura1, Goji Tomita21Inouye Eye Hospital, Tokyo, Japan; 2Second Department of Ophthalmology, Toho University School of Medicine, Tokyo, JapanPurpose: To prospectively investigate adverse reactions to bimatoprost in Japanese patients with glaucoma or ocular hypertension. We also examined patient attitudes to adverse reactions via a questionnaire.Methods: Fifty-two Japanese patients with glaucoma or ocular hypertension were enrolled. Iridial, eyelid, and eyelash photographs were taken before and at 6 months after bimatoprost treatment. Increase in eyelid pigmentation, iridial pigmentation, eyelash growth and bristle, and vellus hair of the lid was assessed from the photographs. Questionnaires completed by patients provided insight into their subjective judgment of adverse reactions.Results: Increase in eyelash bristle (53.8%, iris pigmentation (50.0%, eyelash growth (46.2%, vellus hair of the lid (40.4%, and eyelid pigmentation (7.7% was evident after bimatoprost treatment. The objective and subjective assessments were in agreement in terms of increase in eyelash bristle, eyelash growth, and increase in vellus hair of the lid.Conclusion: Most patients were conscious of these adverse reactions. Before administering bimatoprost, sufficient explanation of potential adverse reactions should be provided; after initiating treatment, careful observation is required.Keywords: bimatoprost, adverse reaction, eyelid pigmentation, changes in eyelashes, iris pigmentation 

  14. Fault detection in IRIS reactor secondary loop using inferential models

    International Nuclear Information System (INIS)

    Perillo, Sergio R.P.; Upadhyaya, Belle R.; Hines, J. Wesley

    2013-01-01

    The development of fault detection algorithms is well-suited for remote deployment of small and medium reactors, such as the IRIS, and the development of new small modular reactors (SMR). However, an extensive number of tests are still to be performed for new engineering aspects and components that are not yet proven technology in the current PWRs, and present some technological challenges for its deployment since many of its features cannot be proven until a prototype plant is built. In this work, an IRIS plant simulation platform was developed using a Simulink® model. The dynamic simulation was utilized in obtaining inferential models that were used to detect faults artificially added to the secondary system simulations. The implementation of data-driven models and the results are discussed. (author)

  15. A hybrid dielectric and iris loaded periodic accelerating structure

    International Nuclear Information System (INIS)

    Zou, P.; Xiao, L.; Sun, X.; Gai, W.

    2001-01-01

    One disadvantage of conventional iris-loaded accelerating structures is the high ratio of the peak surface electric field to the peak axial electric field useful for accelerating a beam. Typically this ratio E s /E a ≥ 2. The high surface electric field relative to the accelerating gradient may prove to be a limitation for realizing technologies for very high gradient accelerators. In this paper, we present a scheme that uses a hybrid dielectric and iris loaded periodic structure to reduce E s /E a to near unity, while the shunt impedance per unit length r and the quality factor Q compare favorably with conventional metallic structures. The analysis based on MAFIA simulations of such structures shows that we can lower the peak surface electric field close to the accelerating gradient while maintaining high acceleration efficiency as measured by r/Q. Numerical examples of X-band hybrid accelerating structures are given

  16. Locating An IRIS From Image Using Canny And Hough Transform

    Directory of Open Access Journals (Sweden)

    Poorvi Bhatt

    2017-11-01

    Full Text Available Iris recognition a relatively new biometric technology has great advantages such as variability stability and security thus it is the most promising for high security environments. The proposed system here is a simple system design and implemented to find the iris from the image using Hough Transform Algorithm. Canny Edge detector has been used to get edge image to use it as an input to the Hough Transform. To get the general idea of Hough Transform the Hough Transform for circle is also implemented. RGB value of 3-D accumulator array of peaks of inner circle and outer circle has been performed. And at the end some suggestions are made to improve the system and performance gets discussed.

  17. The Valduc waste incineration facility starts operations (iris process)

    International Nuclear Information System (INIS)

    Chateauvieux, H.; Guiberteuau, P.; Longuet, T.; Lannaud, J.; Lorich, M.

    1998-01-01

    In the operation of its facilities the Valduc Research Center produces alpha-contaminated solid waste and thus decided to build an incineration facility to treat the most contaminated combustible waste. The process selected for waste incineration is the IRIS process developed by the CEA at the Marcoule Nuclear Research Center. The Valduc Center asked SGN to build the incineration facility. The facility was commissioned in late 1996, and inactive waste incineration campaigns were run in 1997. The operator conducted tests with calibrated radioactive sources to qualify the systems for measuring holdup of active material from outside the equipment. Chlorinated waste incineration test runs were performed using the phosphatizing process developed by the Marcoule Research Center. Inspections performed after these incineration runs revealed the complete absence of corrosion in the equipment. Active commissioning of the facility is scheduled for mid-1998. The Valduc incinerator is the first industrial application of the IRIS process. (author)

  18. Climate information for public health: the role of the IRI climate data library in an integrated knowledge system.

    Science.gov (United States)

    del Corral, John; Blumenthal, M Benno; Mantilla, Gilma; Ceccato, Pietro; Connor, Stephen J; Thomson, Madeleine C

    2012-09-01

    Public health professionals are increasingly concerned about the potential impact of climate variability and change on health outcomes. Protecting public health from the vagaries of climate requires new working relationships between the public health sector and the providers of climate data and information. The Climate Information for Public Health Action initiative at the International Research Institute for Climate and Society (IRI) is designed to increase the public health community's capacity to understand, use and demand appropriate climate data and climate information to mitigate the public health impacts of the climate. Significant challenges to building the capacity of health professionals to use climate information in research and decision-making include the difficulties experienced by many in accessing relevant and timely quality controlled data and information in formats that can be readily incorporated into specific analysis with other data sources. We present here the capacities of the IRI climate data library and show how we have used it to build an integrated knowledge system in the support of the use of climate and environmental information in climate-sensitive decision-making with respect to health. Initiated as an aid facilitating exploratory data analysis for climate scientists, the IRI climate data library has emerged as a powerful tool for interdisciplinary researchers focused on topics related to climate impacts on society, including health.

  19. Proceedings of the IRI task force activity 1995

    International Nuclear Information System (INIS)

    Radicella, S.M.

    1996-05-01

    The report contains the programme, conclusions and the write up of 11 presentations delivered during the International Reference Ionosphere (IRI) Task Force Activity 1995 that took place at the ICTP Trieste between 13-17 November 1995. The presentations included have been grouped in three chapters: Status report and data availability (2 presentations), Electron density profile shape below Nmax (5 presentations) and Intermediate regions (F1) electron density profile (4 presentations). Each presentation was indexed separately. Refs, figs, tabs

  20. IRIS Toxicological Review of Trichloroacetic Acid (Tca) (Final ...

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Trichloroacetic Acid: in support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. The draft Toxicological Review of Trichloroacetic Acid provides scientific support and rationale for the hazard identification and dose-response assessment pertaining to chronic exposure to trichloroacetic acid.

  1. Parallel-Bit Stream for Securing Iris Recognition

    OpenAIRE

    Elsayed Mostafa; Maher Mansour; Heba Saad

    2012-01-01

    Biometrics-based authentication schemes have usability advantages over traditional password-based authentication schemes. However, biometrics raises several privacy concerns, it has disadvantages comparing to traditional password in which it is not secured and non revocable. In this paper, we propose a fast method for securing revocable iris template using parallel-bit stream watermarking to overcome these problems. Experimental results prove that the proposed method has low computation time ...

  2. Bilateral iris, choroid, optic nerve colobomas and retinal detachment ...

    African Journals Online (AJOL)

    Rabah M. Shawky

    2013-12-05

    Dec 5, 2013 ... low posterior hair line, partial left simian crease, and short fingers. MRI brain shows frontal ... 2. Case report. A 3.5 year old female child, fifth in order of birth of healthy ... centile), height is 89 cm (3rd percentile), and weight is 14.5 kg .... cephaly in 80%, hearing loss in 50%, iris or retinal coloboma in 60% ...

  3. IRIS Toxicological Review of 1,4-Dioxane (with Inhalation ...

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of 1,4-Dioxane (with inhalation update) that when finalized will appear on the Integrated Risk Information System (IRIS) database. 1,4-Dioxane is commonly used as a solvent, cleaning agent, chemical stabilizer, surface coating, adhesive agent, and an ingredient in chemical manufacture.

  4. Longitudinal coupling impedance of a thick iris collimator

    International Nuclear Information System (INIS)

    Gluckstern, R.L.; Jiang, S.

    1992-01-01

    A previous calculation of the longitudinal coupling impedance of an iris in a beam pipe turned out not to be well convergent. In this work an alternate basis vector for the matrix equations is constructed, leading to convergent results. Numerical results are presented for the limit a/b → ∞, corresponding to a beam passing through a circular hole in a thick wall. 4 figs., 4 refs

  5. Prominence and tornado dynamics observed with IRIS and THEMIS

    Science.gov (United States)

    Schmieder, Brigitte; Levens, Peter; Labrosse, Nicolas; Mein, Pierre; Lopez Ariste, Arturo; Zapior, Maciek

    2017-08-01

    Several prominences were observed during campaigns in September 2013 and July 2014 with the IRIS spectrometer and the vector magnetograph THEMIS (Tenerife). SDO/AIA and IRIS provided images and spectra of prominences and tornadoes corresponding to different physical conditions of the transition region between the cool plasma and the corona. The vector magnetic field was derived from THEMIS observations by using the He D3 depolarisation due to the magnetic field. The inversion code (PCA) takes into account the Hanle and Zeeman effects and allows us to compute the strength and the inclination of the magnetic field which is shown to be mostly horizontal in prominences as well as in tornadoes. Movies from SDO/AIA in 304 A and Hinode/SOT in Ca II show the highly dynamic nature of the fine structures. From spectra in Mg II and Si IV lines provided by IRIS and H-alpha observed by the Multi-channel Subtractive Double Pass (MSDP) spectrograph in the Meudon Solar Tower we derived the Doppler shifts of the fine structures and reconstructed the 3D structure of tornadoes. We conclude that the apparent rotation of AIA tornadoes is due to large-scale quasi-periodic oscillations of the plasma along more or less horizontal magnetic structures.

  6. IRI related data and model services at NSSDC

    Science.gov (United States)

    Bilitza, D.; Papitashvili, N.; King, J.

    NASA's National Space Science Data Center (NSSDC) provides internet access to a large number of space physics data sets and models. We will review and explain the different products and services that might be of interest to the IRI community. Data can be obtained directly through anonymous ftp or through the SPyCAT WWW interface to a large volume of space physics data on juke-box type mass storage devices. A newly developed WWW system, the ATMOWeb, provides browse and sub-setting capabilities for selected atmospheric and thermospheric data. NSSDC maintains an archive of space physics models that includes a subset of ionospheric models. The model software can be retrieved via anonymous ftp. A selection of the most frequently requested models can be run on-line through special WWW interfaces. Currently supported models include the International Reference Ionosphere (IRI), the Mass Spectrometer and Incoherent Scatter (MSIS) atmospheric model, the International Geomagnetic Reference Field (IGRF) and the AE-8/AP-8 radiation belt models. In this article special emphasis will be given to the IRI interface and its various input/output options. Several new options and a Java-based plotting capability were recently added to the Web interface.

  7. Fuel management options to extend the IRIS reactor cycle

    International Nuclear Information System (INIS)

    Petrovic, B.; Franceschini, F.

    2004-01-01

    To optimize plant operation, reduce scheduled maintenance outage, and increase capacity factor, IRIS is designed to enable extended cycles of up to four years. However, due to the enrichment licensing limitation (less than 5% enriched uranium oxide) there is a tradeoff between the achievable cycle length and fuel utilization, i.e., the average fuel discharge burnup. The longest individual cycle may be achieved with the single-batch straight burn, but at the expense of a lower burnup. Considering the IRIS basic performance requirements, a cycle length in the range of three to four years is deemed desirable. This paper examines different fuel management options, i.e., the influence of the required cycle length on the corresponding reloading strategy, including a two-batch and a three-batch reloading. A reference two-batch core design has been developed for the first cycle, as well as for the transition cycles leading to equilibrium. Main core performance parameters are evaluated. This core design provides the framework for the safety analyses needed to prepare the IRIS safety evaluations. Alternate designs are also considered.(author)

  8. Iris phenotypes and pigment dispersion caused by genes influencing pigmentation.

    Science.gov (United States)

    Anderson, Michael G; Hawes, Norman L; Trantow, Colleen M; Chang, Bo; John, Simon W M

    2008-10-01

    Spontaneous mutations altering mouse coat colors have been a classic resource for discovery of numerous molecular pathways. Although often overlooked, the mouse iris is also densely pigmented and easily observed, thus representing a similarly powerful opportunity for studying pigment cell biology. Here, we present an analysis of iris phenotypes among 16 mouse strains with mutations influencing melanosomes. Many of these strains exhibit biologically and medically relevant phenotypes, including pigment dispersion, a common feature of several human ocular diseases. Pigment dispersion was identified in several strains with mutant alleles known to influence melanosomes, including beige, light, and vitiligo. Pigment dispersion was also detected in the recently arising spontaneous coat color variant, nm2798. We have identified the nm2798 mutation as a missense mutation in the Dct gene, an identical re-occurrence of the slaty light mutation. These results suggest that dysregulated events of melanosomes can be potent contributors to the pigment dispersion phenotype. Combined, these findings illustrate the utility of studying iris phenotypes as a means of discovering new pathways, and re-linking old ones, to processes of pigmented cells in health and disease.

  9. Point spread function engineering for iris recognition system design.

    Science.gov (United States)

    Ashok, Amit; Neifeld, Mark A

    2010-04-01

    Undersampling in the detector array degrades the performance of iris-recognition imaging systems. We find that an undersampling of 8 x 8 reduces the iris-recognition performance by nearly a factor of 4 (on CASIA iris database), as measured by the false rejection ratio (FRR) metric. We employ optical point spread function (PSF) engineering via a Zernike phase mask in conjunction with multiple subpixel shifted image measurements (frames) to mitigate the effect of undersampling. A task-specific optimization framework is used to engineer the optical PSF and optimize the postprocessing parameters to minimize the FRR. The optimized Zernike phase enhanced lens (ZPEL) imager design with one frame yields an improvement of nearly 33% relative to a thin observation module by bounded optics (TOMBO) imager with one frame. With four frames the optimized ZPEL imager achieves a FRR equal to that of the conventional imager without undersampling. Further, the ZPEL imager design using 16 frames yields a FRR that is actually 15% lower than that obtained with the conventional imager without undersampling.

  10. LDPC and SHA based iris recognition for image authentication

    Directory of Open Access Journals (Sweden)

    K. Seetharaman

    2012-11-01

    Full Text Available We introduce a novel way to authenticate an image using Low Density Parity Check (LDPC and Secure Hash Algorithm (SHA based iris recognition method with reversible watermarking scheme, which is based on Integer Wavelet Transform (IWT and threshold embedding technique. The parity checks and parity matrix of LDPC encoding and cancellable biometrics i.e., hash string of unique iris code from SHA-512 are embedded into an image for authentication purpose using reversible watermarking scheme based on IWT and threshold embedding technique. Simply by reversing the embedding process, the original image, parity checks, parity matrix and SHA-512 hash are extracted back from watermarked-image. For authentication, the new hash string produced by employing SHA-512 on error corrected iris code from live person is compared with hash string extracted from watermarked-image. The LDPC code reduces the hamming distance for genuine comparisons by a larger amount than for the impostor comparisons. This results in better separation between genuine and impostor users which improves the authentication performance. Security of this scheme is very high due to the security complexity of SHA-512, which is 2256 under birthday attack. Experimental results show that this approach can assure more accurate authentication with a low false rejection or false acceptance rate and outperforms the prior arts in terms of PSNR.

  11. Information fusion in personal biometric authentication based on the iris pattern

    International Nuclear Information System (INIS)

    Wang, Fenghua; Han, Jiuqiang

    2009-01-01

    Information fusion in biometrics has received considerable attention. This paper focuses on the application of information fusion techniques in iris recognition. To improve the reliability and accuracy of personal identification based on the iris pattern, this paper proposes the schemes of multialgorithmic fusion and multiinstance fusion. Multialgorithmic fusion integrates the improved phase algorithm and the DCT-based algorithm, and multiinstance fusion combines information from the left iris and the right iris of an individual. Both multialgorithmic fusion and multiinstance fusion are carried out at the matching score level and the support vector machine (SVM)-based fusion rule is utilized to generate fused scores for final decision. The experimental results on the noisy iris database UBIRIS demonstrate that the proposed fusion schemes can perform better than the single recognition systems, and further prove that information fusion techniques are feasible and effective to improve the accuracy and robustness of iris recognition especially under noisy conditions

  12. Feature and score fusion based multiple classifier selection for iris recognition.

    Science.gov (United States)

    Islam, Md Rabiul

    2014-01-01

    The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al.

  13. Uso de la triamcinolona subtenoniana en pacientes con rubeosis del iris Use of intravitreal triamcinolone in patients with iris rubeosis

    Directory of Open Access Journals (Sweden)

    Irene Rojas Rondón

    2008-12-01

    Full Text Available OBJETIVO: Describir el comportamiento de la rubeosis del iris luego de la aplicación de triamcinolona subtenoniana. MÉTODOS: Se realizó un estudio descriptivo de corte longitudinal con 25 pacientes para un total de 32 ojos con diferentes afecciones oculares. Se efectuaron pruebas estadísticas con las variables del estudio y en algunas se utilizó la prueba de los signos de comparación para datos pareados y en otras se aplicó chi cuadrado. Se caracterizaron las variables: edad, sexo, causa de rubeosis del iris y sus estadios, síntomas y tratamiento con láser de panfotocoagulación retiniana. RESULTADOS: La retinopatía diabética proliferativa fue la afección más frecuente en el 76 % de los pacientes, seguida de la oclusión de la vena central retiniana. Del total de pacientes tratados, el 37,5 % evolucionó satisfactoriamente el estado de la rubeosis del iris. Fue mayor el número de pacientes que mejoraron el grado de la rubeosis con tratamiento combinado de láser y triamcinolona subtenoniana, aunque estadísticamente no fue significativo. El estado de la rubeosis mejoró en más de la mitad de los pacientes con tiempo de evolución menor de 6 meses. En aquellos con un tiempo mayor de 6 meses y neovascularización del iris grado III, se pudo estabilizar el glaucoma neovascular. CONCLUSIÓN: Se plantea que la triamcinolona subtenoniana constituye una alternativa para el manejo de este tipo de pacientes.OBJECTIVE: To describe the behaviour of iris rubeosis after using intravitreal triamcinolone. METHODS: A longitudinal descriptive study was performed on 25 patients for a total number of 32 eyes with several ocular diseases. Statistical tests were made with the study variables; sign comparison for paired data and Chi square tests were applied. The variables were age, sex, cause of iris rubeosis and its staging, symptoms and treatment with retinal photocoagulation laser. RESULTS: Proliferative diabetic retinopathy was the most common

  14. Quantitative study of the microvasculature and its endothelial cells in the porcine iris.

    Science.gov (United States)

    Yang, Hongfang; Yu, Paula K; Cringle, Stephen J; Sun, Xinghuai; Yu, Dao-Yi

    2015-03-01

    The roles of the iris microvasculature have been increasingly recognised in the pathogenesis of glaucoma and cataract; however limited information exists regarding the iris microvasculature and its endothelium. This study quantitatively assessed the iris microvascular network and its endothelium using intra-luminal micro-perfusion, fixation, and staining of the porcine iris. The temporal long posterior ciliary artery of 11 isolated porcine eyes was cannulated, perfusion-fixed and labelled using silver nitrate. The iris microvasculature was studied for its distribution, orders and endothelial morphometrics. The density of three layers of microvasculature was measured. Endothelial cell length and width were measured for each vessel order. The iris has an unusual vascular distribution which consisted of abundant large vessels in the middle of the iris stroma, branching over a relatively short distance to the microvasculature located in the superficial and deep stroma as well as the pupil edge. The average vascular density of the middle, superficial, and deep layers were 38.9 ± 1.93%, 10.9 ± 1.61% and 8.0 ± 0.79% respectively. Multiple orders of iris vessels (capillary, 6 orders of arteries, and 4 orders of veins) with relatively large capillary and input arteries (319.5 ± 25.6 μm) were found. Significant heterogeneity of vascular diameter and shape of the endothelia was revealed in different orders of the iris vasculature. Detailed information of topography and endothelium of the iris microvasculature combined with unique structural features of the iris may help us to further understand the physiological and pathogenic roles of the iris in relevant ocular diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Perancangan Program Aplikasi Deteksi Iris Mata untuk Absensi Karyawan Menggunakan Metode Gabor Wavelet

    Directory of Open Access Journals (Sweden)

    Zahedi Zahedi

    2011-06-01

    Full Text Available To take the employees’ absences in a company, a variety of invented tools or technologies are and already used, for example, attendance cards, fingerprints attendance tool, and attendance tool that uses facial recognition. Attendance tool with a facial recognition uses iris recognition of those employees. Iris code has many properties that hard to forge. Thus, the detection and iris recognition is one of the most secure and accurate for identification. 

  16. New modelling strategy for IRIS dynamic response simulation

    International Nuclear Information System (INIS)

    Cammi, A.; Ricotti, M. E.; Casella, F.; Schiavo, F.

    2004-01-01

    The pressurized light water cooled, medium power (1000 MWt) IRIS (International Reactor Innovative and Secure) has been under development for four years by an international consortium of over 21 organizations from ten countries. The plant conceptual design was completed in 2001 and the preliminary design is nearing completion. The pre-application licensing process with NRC started in October, 2002 and IRIS is one of the designs considered by US utilities as part of the ESP (Early Site Permit) process. In this paper the development of an adequate modeling and simulation tool for Dynamics and Control tasks is presented. The key features of the developed simulator are: a) Modularity: the system model is built by connecting the models of its components, which are written independently of their boundary conditions; b) Openness: the code of each component model is clearly readable and close to the original equations and easily customised by the experienced user; c) Efficiency: the simulation code is fast; d) Tool support: the simulation tool is based on reliable, tested and well-documented software. To achieve these objectives, the Modelica language was used as a basis for the development of the simulator. The Modelica language is the results of recent advances in the field of object-oriented, multi-physics, dynamic system modelling. The language definition is open-source and it has already been successfully adopted in several industrial fields. To provide the required capabilities for the analysis, specific models for nuclear reactor components have been developed, to be applied for the dynamic simulation of the IRIS integral reactor, albeit keeping general validity for PWR plants. The following Modelica models have been written to satisfy the IRIS modelling requirements and are presented in this paper: neutronics point kinetic, fuel heat transfer, control rods model, including the innovative internal drive mechanism type, and a once-through type steam generator, thus

  17. Biometric iris image acquisition system with wavefront coding technology

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Yang, Hsi-Wen; Huang, Shao-Hung; Li, Yung-Hui; Tien, Chung-Hao

    2013-09-01

    Biometric signatures for identity recognition have been practiced for centuries. Basically, the personal attributes used for a biometric identification system can be classified into two areas: one is based on physiological attributes, such as DNA, facial features, retinal vasculature, fingerprint, hand geometry, iris texture and so on; the other scenario is dependent on the individual behavioral attributes, such as signature, keystroke, voice and gait style. Among these features, iris recognition is one of the most attractive approaches due to its nature of randomness, texture stability over a life time, high entropy density and non-invasive acquisition. While the performance of iris recognition on high quality image is well investigated, not too many studies addressed that how iris recognition performs subject to non-ideal image data, especially when the data is acquired in challenging conditions, such as long working distance, dynamical movement of subjects, uncontrolled illumination conditions and so on. There are three main contributions in this paper. Firstly, the optical system parameters, such as magnification and field of view, was optimally designed through the first-order optics. Secondly, the irradiance constraints was derived by optical conservation theorem. Through the relationship between the subject and the detector, we could estimate the limitation of working distance when the camera lens and CCD sensor were known. The working distance is set to 3m in our system with pupil diameter 86mm and CCD irradiance 0.3mW/cm2. Finally, We employed a hybrid scheme combining eye tracking with pan and tilt system, wavefront coding technology, filter optimization and post signal recognition to implement a robust iris recognition system in dynamic operation. The blurred image was restored to ensure recognition accuracy over 3m working distance with 400mm focal length and aperture F/6.3 optics. The simulation result as well as experiment validates the proposed code

  18. Lantionpohjan toimintahäiriöt : Fysioterapeuttiset hoitokäytännöt

    OpenAIRE

    Halinen, Erika; Pulkkinen, Sari

    2011-01-01

    Lantionpohjan toimintahäiriöt ovat merkittävä naisten elämänlaatua heikentävä vaiva. Lantionpohjan toimintahäiriöitä ovat virtsaamiseen, ulostamiseen ja seksuaalitoimintoihin liittyvät häiriöt sekä laskeumat ja lantionpohjan alueen kiputilat. Suurimmat riskitekijät toimintahäiriöiden synnylle ovat raskauksien, synnytysten ja ikääntymisen mukanaan tuomat lantionpohjan lihas-, sidekudos- ja hermovauriot tai -muutokset. Lantionpohjan eri rakenteet ja toiminnat ovat läheisessä yhteydessä toisiins...

  19. Iris coloboma in one eye and pigment dispersion syndrome in the fellow eye.

    Science.gov (United States)

    Galvis, Virgilio; Tello, Alejandro; Valarezo, Paul; Prada, Angélica M

    2013-05-22

    We report a case of a 43-year-old patient with coloboma of the iris, zonule, ciliary body, choroid and retina in the right eye and pigment dispersion syndrome in the left eye. Considering the hypothesis of the pigment dispersion syndrome pathogenesis in which a difference of pressures in the anterior and posterior chambers creates a posterior convexity of the iris leading to reverse pupillary block, iris touch and consequently causing pigment dispersion, we suggest that the presence of an iris coloboma, by equalising the pressures in the two chambers, prevented the onset of syndrome in that eye.

  20. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5 ...

    Science.gov (United States)

    The IRIS Toxicological Review of Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) was released for external peer review in September 2016. The EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis supporting the RDX assessment and release a final report of their review. Information regarding the peer review can be found on the SAB website. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for RDX. The outcome of this project is an updated Toxicological Review and IRIS Summary for RDX that will be entered into the IRIS database.

  1. Comparison of Ganglion Cell and Retinal Nerve Fiber Layer Thickness in Pigment Dispersion Syndrome, Pigmentary Glaucoma, and Healthy Subjects with Spectral-domain OCT.

    Science.gov (United States)

    Arifoglu, Hasan Basri; Simavli, Huseyin; Midillioglu, Inci; Berk Ergun, Sule; Simsek, Saban

    2017-01-01

    To evaluate the ganglion cell complex (GCC) and retinal nerve fiber layer (RNFL) thickness in pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG) with RTVue spectral domain optical coherence tomography (SD-OCT). A total of 102 subjects were enrolled: 29 with PDS, 18 with PG, and 55 normal subjects. Full ophthalmic examination including visual field analysis was performed. SD-OCT was used to analyze GCC superior, GCC inferior, and average RNFL thickness. To compare the discrimination capabilities, the areas under the receiver operating characteristic curves were assessed. Superior GCC, inferior GCC, and RNFL thickness values of patients with PG were statistically signicantly lower than those of patients with PDS (p  0.05). The SD-OCT-derived GCC and RNFL thickness parameters can be useful to discriminate PG from both PDS and normal subjects.

  2. Desgarro de epitelio pigmentario retiniano periférico idiopático Tear of the idiopathic peripheral retinal pigmentary epithelium

    Directory of Open Access Journals (Sweden)

    Raúl Reinaldo Leyva Almarales

    2011-06-01

    Full Text Available Los desgarros del epitelio pigmentario de la retina constituyen entidades asociadas a degeneración macular relacionada con la edad con desprendimiento de epitelio pigmentario retiniano. Aunque puede tener múltiples causas, también puede ser idiopático y su localización más frecuente ocurre a nivel del polo posterior retiniano. Se presenta un caso de desgarro de epitelio pigmentario retiniano periférico en paciente sin patología del polo posterior retiniano, el cual se produjo de manera espontánea y no se encontró causa alguna; se realizaron fotos de fondo de ojo a color, autofluorescencia y angiografía con verde indiocianina, que confirmaron el diagnóstico. Por su carácter infrecuente hemos decidido presentar este caso de desgarro de epitelio pigmentario de retina de localización periférica y de causa idiopática.The tears of the retina pigmentary epithelium are entities associated with a macular degeneration related to age in which occur such tears. Although it may to have multiple causes, also may be idiopathic and its more frequent location is at level of retinal posterior pole. Authors present a case of peripheral retinal pigmentary epithelium tear diagnosed in a patient without pathology or retinal posterior pole, which occurred in a spontaneous way with any cause; the fundus oculi color photos were taken, auto-fluorescence and indocyanine green confirmed diagnosis. Due to its infrequent character authors decide to present this above mentioned case and of idiopathic cause.

  3. [Clinical analysis of real-time iris recognition guided LASIK with femtosecond laser flap creation for myopic astigmatism].

    Science.gov (United States)

    Jie, Li-ming; Wang, Qian; Zheng, Lin

    2013-08-01

    To assess the safety, efficacy, stability and changes in cylindrical degree and axis after real-time iris recognition guided LASIK with femtosecond laser flap creation for the correction of myopic astigmatism. Retrospective case series. This observational case study comprised 136 patients (249 eyes) with myopic astigmatism in a 6-month trial. Patients were divided into 3 groups according to the pre-operative cylindrical degree: Group 1, -0.75 to -1.25 D, 106 eyes;Group 2, -1.50 to -2.25 D, 89 eyes and Group 3, -2.50 to -5.00 D, 54 eyes. They were also grouped by pre-operative astigmatism axis:Group A, with the rule astigmatism (WTRA), 156 eyes; Group B, against the rule astigmatism (ATRA), 64 eyes;Group C, oblique axis astigmatism, 29 eyes. After femtosecond laser flap created, real-time iris recognized excimer ablation was performed. The naked visual acuity, the best-corrected visual acuity, the degree and axis of astigmatism were analyzed and compared at 1, 3 and 6 months postoperatively. Static iris recognition detected that eye cyclotorsional misalignment was 2.37° ± 2.16°, dynamic iris recognition detected that the intraoperative cyclotorsional misalignment range was 0-4.3°. Six months after operation, the naked visual acuity was 0.5 or better in 100% cases. No eye lost ≥ 1 line of best spectacle-corrected visual acuity (BSCVA). Six months after operation, the naked vision of 227 eyes surpassed the BSCVA, and 87 eyes gained 1 line of BSCVA. The degree of astigmatism decreased from (-1.72 ± 0.77) D (pre-operation) to (-0.29 ± 0.25) D (post-operation). Six months after operation, WTRA from 157 eyes (pre-operation) decreased to 43 eyes (post-operation), ATRA from 63 eyes (pre-operation) decreased to 28 eyes (post-operation), oblique astigmatism increased from 29 eyes to 34 eyes and 144 eyes became non-astigmatism. The real-time iris recognition guided LASIK with femtosecond laser flap creation can compensate deviation from eye cyclotorsion, decrease

  4. Hyaluronic acid production and hyaluronidase activity in the newt iris during lens regeneration

    International Nuclear Information System (INIS)

    Kulyk, W.M.; Zalik, S.E.; Dimitrov, E.

    1987-01-01

    The process of lens regeneration in newts involves the dedifferentiation of pigmented iris epithelial cells and their subsequent conversion into lens fibers. In vivo this cell-type conversion is restricted to the dorsal region of the iris. We have examined the patterns of hyaluronate accumulation and endogenous hyaluronidase activity in the newt iris during the course of lens regeneration in vivo. Accumulation of newly synthesized hyaluronate was estimated from the uptake of [ 3 H]glucosamine into cetylpyridinium chloride-precipitable material that was sensitive to Streptomyces hyaluronidase. Endogenous hyaluronidase activity was determined from the quantity of reducing N-acetylhexosamine released upon incubation of iris tissue extract with exogenous hyaluronate substrate. We found that incorporation of label into hyaluronate was consistently higher in the regeneration-activated irises of lentectomized eyes than in control irises from sham-operated eyes. Hyaluronate labeling was higher in the dorsal (lens-forming) region of the iris than in ventral (non-lens-forming) iris tissue during the regeneration process. Label accumulation into hyaluronate was maximum between 10 and 15 days after lentectomy, the period of most pronounced dedifferentiation in the dorsal iris epithelium. Both normal and regenerating irises demonstrated a high level of endogenous hyaluronidase activity with a pH optimum of 3.5-4.0. Hyaluronidase activity was 1.7 to 2 times higher in dorsal iris tissue than in ventral irises both prior to lentectomy and throughout the regeneration process. We suggest that enhanced hyaluronate accumulation may facilitate the dedifferentiation of iris epithelial cells in the dorsal iris and prevent precocious withdrawal from the cell cycle. The high level of hyaluronidase activity in the dorsal iris may promote the turnover and remodeling of extracellular matrix components required for cell-type conversion

  5. Use of PRA techniques to optimize the design of the IRIS nuclear power plant

    International Nuclear Information System (INIS)

    Muhlheim, M.D.; Cletcher, J.W. II

    2003-01-01

    True design optimization of a plants inherent safety and performance characteristics results when a probabilistic risk assessment (PRA) is integrated with the plant-level design process. This is the approach being used throughout the design of the International Reactor Innovative and Secure (IRIS) nuclear power plant to maximize safety. A risk-based design optimization tool employing a 'one-button' architecture is being developed by the Oak Ridge National Laboratory to evaluate design changes; new modeling approaches, methods, or theories modeling uncertainties and completeness; physical assumptions; and data changes on component, cabinet, train, and system bases. Unlike current PRAs, the one-button architecture allows components, modules, and data to be interchanged at will with the probabilistic effect immediately apparent. Because all of the current and previous design, and data sets are available via the one-button architecture, the safety ramifications of design options are evaluated, feedback on design alternatives is immediate, and true optimization and understanding can be achieved. Thus, for the first time, PRA analysts and designers can easily determine the probabilistic implications of different design configurations and operating conditions in various combinations for the entire range of initiating events. The power of the one-button architecture becomes evident by the number of design alternatives that can be evaluated C11 component choices yielded 160 design alternatives. Surprisingly, the lessons learned can be counter-intuitive and significant. For example, one of the alternative designs for IRIS evaluated via this architecture revealed that because of common-cause failure probabilities, using the most reliable components actually decreased systems' reliability. (author)

  6. Anterior Lens Capsule and Iris Thicknesses in Pseudoexfoliation Syndrome.

    Science.gov (United States)

    Batur, Muhammed; Seven, Erbil; Tekin, Serek; Yasar, Tekin

    2017-11-01

    The aim of this study was to evaluate anatomic properties of the lens capsule and iris by anterior segment optical coherence tomography (AS-OCT) in patients with pseudoexfoliation (PEX). This prospective study included 62 eyes of 62 patients with PEX syndrome and 43 eyes of 43 age- and gender-matched controls. All subjects underwent full ophthalmologic examinations including AS-OCT. Pupillary diameter, midperipheral stromal iris thickness, central and temporal lens capsule thicknesses, and peripheral pseudoexfoliation material thickness on the anterior lens capsule surface were measured and recorded. Mean age was 66.8 ± 9.3 years in the PEX group and 65.5 ± 8.9 years in the control group (p = 0.44). The PEX group consisted of 62 patients: 38 men (61.3%) and 24 women (38.7%); the control group included 43 subjects: 25 men (58.1%) and 18 women (41.9%). Pupillary diameter after pharmacologic mydriasis was 21% smaller in the PEX group than controls. Mean midperipheral iris thickness was 36 ± 7.2 μm (7.8%) thinner in the PEX group than that of control group (p = 0.047). The central anterior capsule was a mean of 3.40 ± 0.51 μm (18%) thicker in the PEX group compared to the control group (p = 0.0001). The temporal anterior lens capsule was a mean of 0.17 ± 0.15 μm thicker in the PEX group compared to the control group (p = 0.81). With high-resolution OCT imaging, it has become possible to evaluate the anterior lens capsule without histologic examination and demonstrate that it is thicker than normal in PEX patients.

  7. Reliability of Iris Scanning as a Means of Identity Verification and Future Impact on Transportation Worker Identification Credential

    National Research Council Canada - National Science Library

    McLaren, Simon

    2008-01-01

    .... Congress mandated the TWIC have a biometric authenticator; DHS chose fingerprints. This thesis argues iris scanning is a better choice because of the nature of the maritime environment and because iris scanning is a more accurate biometric...

  8. Proceedings of the IRI task force activity 2000

    International Nuclear Information System (INIS)

    Radicella, Sandro M.

    2001-05-01

    This internal report of the International Center for Theoretical Physics (ICTP) contains presentations delivered during the International Reference Ionosphere Task Force Activity 2000 which took place at the Abdus Salam ICTP during July 2000. The 2000 Task Force Activity is the seventh successful encounter of specialists organized by the URSI-COSPAR IRI Working Group and the Aeronomy and Radiopropagation Laboratory of the ICTP of Trieste, Italy. The main topic of this task force activity was the modeling of the topside ionosphere and the development of strategies for modeling of ionospheric variability

  9. A new method for generating an invariant iris private key based on the fuzzy vault system.

    Science.gov (United States)

    Lee, Youn Joo; Park, Kang Ryoung; Lee, Sung Joo; Bae, Kwanghyuk; Kim, Jaihie

    2008-10-01

    Cryptographic systems have been widely used in many information security applications. One main challenge that these systems have faced has been how to protect private keys from attackers. Recently, biometric cryptosystems have been introduced as a reliable way of concealing private keys by using biometric data. A fuzzy vault refers to a biometric cryptosystem that can be used to effectively protect private keys and to release them only when legitimate users enter their biometric data. In biometric systems, a critical problem is storing biometric templates in a database. However, fuzzy vault systems do not need to directly store these templates since they are combined with private keys by using cryptography. Previous fuzzy vault systems were designed by using fingerprint, face, and so on. However, there has been no attempt to implement a fuzzy vault system that used an iris. In biometric applications, it is widely known that an iris can discriminate between persons better than other biometric modalities. In this paper, we propose a reliable fuzzy vault system based on local iris features. We extracted multiple iris features from multiple local regions in a given iris image, and the exact values of the unordered set were then produced using the clustering method. To align the iris templates with the new input iris data, a shift-matching technique was applied. Experimental results showed that 128-bit private keys were securely and robustly generated by using any given iris data without requiring prealignment.

  10. Gaze Estimation for Off-Angle Iris Recognition Based on the Biometric Eye Model

    Energy Technology Data Exchange (ETDEWEB)

    Karakaya, Mahmut [ORNL; Barstow, Del R [ORNL; Santos-Villalobos, Hector J [ORNL; Thompson, Joseph W [ORNL; Bolme, David S [ORNL; Boehnen, Chris Bensing [ORNL

    2013-01-01

    Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ANONYMIZED biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction from elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.

  11. Modeling IrisCode and its variants as convex polyhedral cones and its security implications.

    Science.gov (United States)

    Kong, Adams Wai-Kin

    2013-03-01

    IrisCode, developed by Daugman, in 1993, is the most influential iris recognition algorithm. A thorough understanding of IrisCode is essential, because over 100 million persons have been enrolled by this algorithm and many biometric personal identification and template protection methods have been developed based on IrisCode. This paper indicates that a template produced by IrisCode or its variants is a convex polyhedral cone in a hyperspace. Its central ray, being a rough representation of the original biometric signal, can be computed by a simple algorithm, which can often be implemented in one Matlab command line. The central ray is an expected ray and also an optimal ray of an objective function on a group of distributions. This algorithm is derived from geometric properties of a convex polyhedral cone but does not rely on any prior knowledge (e.g., iris images). The experimental results show that biometric templates, including iris and palmprint templates, produced by different recognition methods can be matched through the central rays in their convex polyhedral cones and that templates protected by a method extended from IrisCode can be broken into. These experimental results indicate that, without a thorough security analysis, convex polyhedral cone templates cannot be assumed secure. Additionally, the simplicity of the algorithm implies that even junior hackers without knowledge of advanced image processing and biometric databases can still break into protected templates and reveal relationships among templates produced by different recognition methods.

  12. Hybridization between ecotypes in a phenotypically and ecologically heterogeneous population of Iris savannarum (Iridaceae) in Florida.

    Science.gov (United States)

    Iris series Hexagonae is a small, monophyletic complex of 5 species and associated hybrid populations, popularly known as the “Louisiana irises.” The Hexagonae alliance of Iris have been recognized as a textbook case of introgressive hybridization based on numerous studies in Louisiana. We previou...

  13. IRIS Assessment Plan for Ammonia and Ammonium Salts Noncancer Oral (Scoping and Problem Formulation Materials)

    Science.gov (United States)

    In April 2018, EPA released the draft IRIS Assessment Plan for Ammonia and Ammonium Salts Noncancer Oral. The IAP communicates to the public the plan for assessing each individual chemical and includes summary information on the IRIS Program’s scoping and initial proble...

  14. Opening of cut Iris x hollandica flowers as affected by temperature, dry storage, and light

    NARCIS (Netherlands)

    Doorn, van W.G.; Dole, I.; Celikel, F.G.; Harkema, H.

    2014-01-01

    Flower opening in Iris (Iris x hollandica) depends on elongation of the pedicel + ovary. This elongation lifts the bud above the point where the sheath leaves no longer mechanically inhibit lateral tepal movement. We here report on the effects on flower opening of storage at various temperatures, of

  15. Protective effect of Iris germanica L. in β-amyloid-induced animal ...

    African Journals Online (AJOL)

    Protective effect of Iris germanica L. in β-amyloid-induced animal model of alzheimer's disease. ... The day after surgery, animals in treatment groups received different doses of the aqueous extract of Iris by gavage for 30 days. Morris water maze test (MWM) was performed to assess the effects of I. germanica on learning ...

  16. Antigen-Specific Interferon-Gamma Responses and Innate Cytokine Balance in TB-IRIS

    NARCIS (Netherlands)

    Goovaerts, Odin; Jennes, Wim; Massinga-Loembé, Marguerite; Ceulemans, Ann; Worodria, William; Mayanja-Kizza, Harriet; Colebunders, Robert; Kestens, Luc; Loembé, Marguerite Massinga; Mayanja, Harriet; Mascart, Francoise; van den Bergh, Rafael; Locht, Camille; Reiss, Peter; Cobelens, Frank; Ondoa, Pascale; Pakker, Nadine; Mugerwa, Roy

    2014-01-01

    Background: Tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) remains a poorly understood complication in HIV-TB patients receiving antiretroviral therapy (ART). TB-IRIS could be associated with an exaggerated immune response to TB-antigens. We compared the recovery of

  17. IRIS Toxicological Review of Tert-Butyl Alcohol (Tert-Butanol) (Public Comment Draft)

    Science.gov (United States)

    EPA is developing an Integrated Risk Information System (IRIS) assessment of tert-butyl Alcohol (tert-butanol) and has released the public comment draft assessment for public comment and external peer review. When final, the assessment will appear on the IRIS databa...

  18. Method of preliminary localization of the iris in biometric access control systems

    Science.gov (United States)

    Minacova, N.; Petrov, I.

    2015-10-01

    This paper presents a method of preliminary localization of the iris, based on the stable brightness features of the iris in images of the eye. In tests on images of eyes from publicly available databases method showed good accuracy and speed compared to existing methods preliminary localization.

  19. 77 FR 41784 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2012-07-16

    ... System (IRIS); Announcement of Availability of Literature Searches for IRIS Assessments AGENCY: Environmental Protection Agency. ACTION: Notice of availability of a literature search for benzo(a)pyrene... availability of a literature search for benzo(a)pyrene (CASRN 50- 32-8). EPA is also requesting scientific...

  20. IRIS Toxicological Review of Ammonia Noncancer Inhalation (Interagency Science Discussion Draft)

    Science.gov (United States)

    In September 2016, EPA finalized the IRIS assessment of Ammonia (Noncancer Inhalation). The Toxicological Review was reviewed internally by EPA and by other federal agencies and White House Offices before public release in June 2016. Consistent with the May 2009 IRIS assessment d...