WorldWideScience

Sample records for iris images custom

  1. Enhanced iris recognition method based on multi-unit iris images

    Science.gov (United States)

    Shin, Kwang Yong; Kim, Yeong Gon; Park, Kang Ryoung

    2013-04-01

    For the purpose of biometric person identification, iris recognition uses the unique characteristics of the patterns of the iris; that is, the eye region between the pupil and the sclera. When obtaining an iris image, the iris's image is frequently rotated because of the user's head roll toward the left or right shoulder. As the rotation of the iris image leads to circular shifting of the iris features, the accuracy of iris recognition is degraded. To solve this problem, conventional iris recognition methods use shifting of the iris feature codes to perform the matching. However, this increases the computational complexity and level of false acceptance error. To solve these problems, we propose a novel iris recognition method based on multi-unit iris images. Our method is novel in the following five ways compared with previous methods. First, to detect both eyes, we use Adaboost and a rapid eye detector (RED) based on the iris shape feature and integral imaging. Both eyes are detected using RED in the approximate candidate region that consists of the binocular region, which is determined by the Adaboost detector. Second, we classify the detected eyes into the left and right eyes, because the iris patterns in the left and right eyes in the same person are different, and they are therefore considered as different classes. We can improve the accuracy of iris recognition using this pre-classification of the left and right eyes. Third, by measuring the angle of head roll using the two center positions of the left and right pupils, detected by two circular edge detectors, we obtain the information of the iris rotation angle. Fourth, in order to reduce the error and processing time of iris recognition, adaptive bit-shifting based on the measured iris rotation angle is used in feature matching. Fifth, the recognition accuracy is enhanced by the score fusion of the left and right irises. Experimental results on the iris open database of low-resolution images showed that the

  2. Iris Image Classification Based on Hierarchical Visual Codebook.

    Science.gov (United States)

    Zhenan Sun; Hui Zhang; Tieniu Tan; Jianyu Wang

    2014-06-01

    Iris recognition as a reliable method for personal identification has been well-studied with the objective to assign the class label of each iris image to a unique subject. In contrast, iris image classification aims to classify an iris image to an application specific category, e.g., iris liveness detection (classification of genuine and fake iris images), race classification (e.g., classification of iris images of Asian and non-Asian subjects), coarse-to-fine iris identification (classification of all iris images in the central database into multiple categories). This paper proposes a general framework for iris image classification based on texture analysis. A novel texture pattern representation method called Hierarchical Visual Codebook (HVC) is proposed to encode the texture primitives of iris images. The proposed HVC method is an integration of two existing Bag-of-Words models, namely Vocabulary Tree (VT), and Locality-constrained Linear Coding (LLC). The HVC adopts a coarse-to-fine visual coding strategy and takes advantages of both VT and LLC for accurate and sparse representation of iris texture. Extensive experimental results demonstrate that the proposed iris image classification method achieves state-of-the-art performance for iris liveness detection, race classification, and coarse-to-fine iris identification. A comprehensive fake iris image database simulating four types of iris spoof attacks is developed as the benchmark for research of iris liveness detection.

  3. Iris Recognition: The Consequences of Image Compression

    Directory of Open Access Journals (Sweden)

    Bishop DanielA

    2010-01-01

    Full Text Available Iris recognition for human identification is one of the most accurate biometrics, and its employment is expanding globally. The use of portable iris systems, particularly in law enforcement applications, is growing. In many of these applications, the portable device may be required to transmit an iris image or template over a narrow-bandwidth communication channel. Typically, a full resolution image (e.g., VGA is desired to ensure sufficient pixels across the iris to be confident of accurate recognition results. To minimize the time to transmit a large amount of data over a narrow-bandwidth communication channel, image compression can be used to reduce the file size of the iris image. In other applications, such as the Registered Traveler program, an entire iris image is stored on a smart card, but only 4 kB is allowed for the iris image. For this type of application, image compression is also the solution. This paper investigates the effects of image compression on recognition system performance using a commercial version of the Daugman iris2pi algorithm along with JPEG-2000 compression, and links these to image quality. Using the ICE 2005 iris database, we find that even in the face of significant compression, recognition performance is minimally affected.

  4. Iris Recognition: The Consequences of Image Compression

    Science.gov (United States)

    Ives, Robert W.; Bishop, Daniel A.; Du, Yingzi; Belcher, Craig

    2010-12-01

    Iris recognition for human identification is one of the most accurate biometrics, and its employment is expanding globally. The use of portable iris systems, particularly in law enforcement applications, is growing. In many of these applications, the portable device may be required to transmit an iris image or template over a narrow-bandwidth communication channel. Typically, a full resolution image (e.g., VGA) is desired to ensure sufficient pixels across the iris to be confident of accurate recognition results. To minimize the time to transmit a large amount of data over a narrow-bandwidth communication channel, image compression can be used to reduce the file size of the iris image. In other applications, such as the Registered Traveler program, an entire iris image is stored on a smart card, but only 4 kB is allowed for the iris image. For this type of application, image compression is also the solution. This paper investigates the effects of image compression on recognition system performance using a commercial version of the Daugman iris2pi algorithm along with JPEG-2000 compression, and links these to image quality. Using the ICE 2005 iris database, we find that even in the face of significant compression, recognition performance is minimally affected.

  5. Video-based noncooperative iris image segmentation.

    Science.gov (United States)

    Du, Yingzi; Arslanturk, Emrah; Zhou, Zhi; Belcher, Craig

    2011-02-01

    In this paper, we propose a video-based noncooperative iris image segmentation scheme that incorporates a quality filter to quickly eliminate images without an eye, employs a coarse-to-fine segmentation scheme to improve the overall efficiency, uses a direct least squares fitting of ellipses method to model the deformed pupil and limbic boundaries, and develops a window gradient-based method to remove noise in the iris region. A remote iris acquisition system is set up to collect noncooperative iris video images. An objective method is used to quantitatively evaluate the accuracy of the segmentation results. The experimental results demonstrate the effectiveness of this method. The proposed method would make noncooperative iris recognition or iris surveillance possible.

  6. Iris recognition via plenoptic imaging

    Science.gov (United States)

    Santos-Villalobos, Hector J.; Boehnen, Chris Bensing; Bolme, David S.

    2017-11-07

    Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.

  7. Exploring the feasibility of iris recognition for visible spectrum iris images obtained using smartphone camera

    Science.gov (United States)

    Trokielewicz, Mateusz; Bartuzi, Ewelina; Michowska, Katarzyna; Andrzejewska, Antonina; Selegrat, Monika

    2015-09-01

    In the age of modern, hyperconnected society that increasingly relies on mobile devices and solutions, implementing a reliable and accurate biometric system employing iris recognition presents new challenges. Typical biometric systems employing iris analysis require expensive and complicated hardware. We therefore explore an alternative way using visible spectrum iris imaging. This paper aims at answering several questions related to applying iris biometrics for images obtained in the visible spectrum using smartphone camera. Can irides be successfully and effortlessly imaged using a smartphone's built-in camera? Can existing iris recognition methods perform well when presented with such images? The main advantage of using near-infrared (NIR) illumination in dedicated iris recognition cameras is good performance almost independent of the iris color and pigmentation. Are the images obtained from smartphone's camera of sufficient quality even for the dark irides? We present experiments incorporating simple image preprocessing to find the best visibility of iris texture, followed by a performance study to assess whether iris recognition methods originally aimed at NIR iris images perform well with visible light images. To our best knowledge this is the first comprehensive analysis of iris recognition performance using a database of high-quality images collected in visible light using the smartphones flashlight together with the application of commercial off-the-shelf (COTS) iris recognition methods.

  8. Effect of iris registration on outcomes of LASIK for myopia with the VISX CustomVue platform

    DEFF Research Database (Denmark)

    Moshirfar, Majid; Chen, Michael C; Espandar, Ladan

    2009-01-01

    PURPOSE: To compare visual outcomes after LASIK using the VISX STAR S4 CustomVue, with and without Iris Registration technology. METHODS: In this retrospective study, LASIK was performed on 239 myopic eyes, with or without astigmatism, of 142 patients. Iris registration LASIK was performed on 121...... eyes and non-iris registration LASIK was performed on 118 eyes. Primary outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and manifest refraction. RESULTS: At 6 months, the mean values for UCVA (logMAR) were 0.00 +/- 0.09 in the iris registration...... magnitude of error of surgically induced astigmatism was -0.09 in the iris registration group and -0.04 in the non-iris registration group (P = .25). CONCLUSIONS: Wavefront-guided LASIK with the VISX STAR S4 CustomVue laser system, independent of iris registration status, is effective, safe, and predictable...

  9. Three-dimensional Hessian matrix-based quantitative vascular imaging of rat iris with optical-resolution photoacoustic microscopy in vivo

    Science.gov (United States)

    Zhao, Huangxuan; Wang, Guangsong; Lin, Riqiang; Gong, Xiaojing; Song, Liang; Li, Tan; Wang, Wenjia; Zhang, Kunya; Qian, Xiuqing; Zhang, Haixia; Li, Lin; Liu, Zhicheng; Liu, Chengbo

    2018-04-01

    For the diagnosis and evaluation of ophthalmic diseases, imaging and quantitative characterization of vasculature in the iris are very important. The recently developed photoacoustic imaging, which is ultrasensitive in imaging endogenous hemoglobin molecules, provides a highly efficient label-free method for imaging blood vasculature in the iris. However, the development of advanced vascular quantification algorithms is still needed to enable accurate characterization of the underlying vasculature. We have developed a vascular information quantification algorithm by adopting a three-dimensional (3-D) Hessian matrix and applied for processing iris vasculature images obtained with a custom-built optical-resolution photoacoustic imaging system (OR-PAM). For the first time, we demonstrate in vivo 3-D vascular structures of a rat iris with a the label-free imaging method and also accurately extract quantitative vascular information, such as vessel diameter, vascular density, and vascular tortuosity. Our results indicate that the developed algorithm is capable of quantifying the vasculature in the 3-D photoacoustic images of the iris in-vivo, thus enhancing the diagnostic capability of the OR-PAM system for vascular-related ophthalmic diseases in vivo.

  10. Iris recognition and what is next? Iris diagnosis: a new challenging topic for machine vision from image acquisition to image interpretation

    Science.gov (United States)

    Perner, Petra

    2017-03-01

    Molecular image-based techniques are widely used in medicine to detect specific diseases. Look diagnosis is an important issue but also the analysis of the eye plays an important role in order to detect specific diseases. These topics are important topics in medicine and the standardization of these topics by an automatic system can be a new challenging field for machine vision. Compared to iris recognition has the iris diagnosis much more higher demands for the image acquisition and interpretation of the iris. One understands by iris diagnosis (Iridology) the investigation and analysis of the colored part of the eye, the iris, to discover factors, which play an important role for the prevention and treatment of illnesses, but also for the preservation of an optimum health. An automatic system would pave the way for a much wider use of the iris diagnosis for the diagnosis of illnesses and for the purpose of individual health protection. With this paper, we describe our work towards an automatic iris diagnosis system. We describe the image acquisition and the problems with it. Different ways are explained for image acquisition and image preprocessing. We describe the image analysis method for the detection of the iris. The meta-model for image interpretation is given. Based on this model we show the many tasks for image analysis that range from different image-object feature analysis, spatial image analysis to color image analysis. Our first results for the recognition of the iris are given. We describe how detecting the pupil and not wanted lamp spots. We explain how to recognize orange blue spots in the iris and match them against the topological map of the iris. Finally, we give an outlook for further work.

  11. SEGMENTATION AND QUALITY ANALYSIS OF LONG RANGE CAPTURED IRIS IMAGE

    Directory of Open Access Journals (Sweden)

    Anand Deshpande

    2016-05-01

    Full Text Available The iris segmentation plays a major role in an iris recognition system to increase the performance of the system. This paper proposes a novel method for segmentation of iris images to extract the iris part of long range captured eye image and an approach to select best iris frame from the iris polar image sequences by analyzing the quality of iris polar images. The quality of iris image is determined by the frequency components present in the iris polar images. The experiments are carried out on CASIA-long range captured iris image sequences. The proposed segmentation method is compared with Hough transform based segmentation and it has been determined that the proposed method gives higher accuracy for segmentation than Hough transform.

  12. Image compression with Iris-C

    Science.gov (United States)

    Gains, David

    2009-05-01

    Iris-C is an image codec designed for streaming video applications that demand low bit rate, low latency, lossless image compression. To achieve compression and low latency the codec features the discrete wavelet transform, Exp-Golomb coding, and online processes that construct dynamic models of the input video. Like H.264 and Dirac, the Iris-C codec accepts input video from both the YUV and YCOCG colour spaces, but the system can also operate on Bayer RAW data read directly from an image sensor. Testing shows that the Iris-C codec is competitive with the Dirac low delay syntax codec which is typically regarded as the state-of-the-art low latency, lossless video compressor.

  13. Extending the imaging volume for biometric iris recognition.

    Science.gov (United States)

    Narayanswamy, Ramkumar; Johnson, Gregory E; Silveira, Paulo E X; Wach, Hans B

    2005-02-10

    The use of the human iris as a biometric has recently attracted significant interest in the area of security applications. The need to capture an iris without active user cooperation places demands on the optical system. Unlike a traditional optical design, in which a large imaging volume is traded off for diminished imaging resolution and capacity for collecting light, Wavefront Coded imaging is a computational imaging technology capable of expanding the imaging volume while maintaining an accurate and robust iris identification capability. We apply Wavefront Coded imaging to extend the imaging volume of the iris recognition application.

  14. Quality assessment for online iris images

    CSIR Research Space (South Africa)

    Makinana, S

    2015-01-01

    Full Text Available Iris recognition systems have attracted much attention for their uniqueness, stability and reliability. However, performance of this system depends on quality of iris image. Therefore there is a need to select good quality images before features can...

  15. Treatment of non-resectable malignant iris tumours with custom designed plaque radiotherapy

    International Nuclear Information System (INIS)

    Shields, C.L.; Shields, J.A.; Potter, P. De; Singh, A.D.; Hernandez, C.; Brady, L.W.

    1995-01-01

    Background- Plaque radiotherapy is the most common method of managing posterior uveal melanoma but its use for iris melanoma and iris metastases has not yet been evaluated. Methods -Fourteen patients with non-resectable iris melanoma and four with iris metastasis were treated with plaque radiotherapy. The tumour response to treatment and the local side effects of the radioactive plaque were evaluated. Results -In the iris melanoma group over a mean follow up of 26 (range 6-75) months, the tumour regressed in 13 of the 14 patients (93%) and recurred as diffuse seeding in one patient (7%). Despite large doses of radiation given transcorneally, the cornea developed epitheliopathy, abraxion, and oedema in only one case each. The major radiation side effects were localised iris vasculopathy without glaucoma in two cases, posterior synechiae in five cases, and cataract in six cases. In the iris metastasis group, tumour regression was observed in all four patients (100%) and radiation side effects were not evident over the relatively short mean follow up period of 8 (range 4-9) months. All of the 14 patients with irradiated iris melanoma have remained systemically healthy without metastasis while three of the four patients with irradiated iris metastases have died of metastases from the primary neoplasm. Conclusion - Custom designed plaque radiotherapy appears to be an effective alternative method of controlling non-resectable diffuse iris melanoma and solitary iris metastasis and has relatively few side effects. (author)

  16. SINGLE FRAME SUPER RESOLUTION OF NONCOOPERATIVE IRIS IMAGES

    Directory of Open Access Journals (Sweden)

    Anand Deshpande

    2016-11-01

    Full Text Available Image super-resolution, a process to enhance image resolution, has important applications in biometrics, satellite imaging, high definition television, medical imaging, etc. The long range captured iris identification systems often suffer from low resolution and meager focus of the captured iris images. These degrade the iris recognition performance. This paper proposes enhanced iterated back projection (EIBP method to super resolute the long range captured iris polar images. The performance of proposed method is tested and analyzed on CASIA long range iris database by comparing peak signal to noise ratio (PSNR and structural similarity index (SSIM with state-of-the-art super resolution (SR algorithms. It is further analyzed by increasing the up-sampling factor. Performance analysis shows that the proposed method is superior to state-of-the-art algorithms, the peak signal-to-noise ratio improved about 0.1-1.5 dB. The results demonstrate that the proposed method is well suited to super resolve the iris polar images captured at a long distance

  17. An effective approach for iris recognition using phase-based image matching.

    Science.gov (United States)

    Miyazawa, Kazuyuki; Ito, Koichi; Aoki, Takafumi; Kobayashi, Koji; Nakajima, Hiroshi

    2008-10-01

    This paper presents an efficient algorithm for iris recognition using phase-based image matching--an image matching technique using phase components in 2D Discrete Fourier Transforms (DFTs) of given images. Experimental evaluation using CASIA iris image databases (versions 1.0 and 2.0) and Iris Challenge Evaluation (ICE) 2005 database clearly demonstrates that the use of phase components of iris images makes possible to achieve highly accurate iris recognition with a simple matching algorithm. This paper also discusses major implementation issues of our algorithm. In order to reduce the size of iris data and to prevent the visibility of iris images, we introduce the idea of 2D Fourier Phase Code (FPC) for representing iris information. The 2D FPC is particularly useful for implementing compact iris recognition devices using state-of-the-art Digital Signal Processing (DSP) technology.

  18. Evaluating the impact of image preprocessing on iris segmentation

    Directory of Open Access Journals (Sweden)

    José F. Valencia-Murillo

    2014-08-01

    Full Text Available Segmentation is one of the most important stages in iris recognition systems. In this paper, image preprocessing algorithms are applied in order to evaluate their impact on successful iris segmentation. The preprocessing algorithms are based on histogram adjustment, Gaussian filters and suppression of specular reflections in human eye images. The segmentation method introduced by Masek is applied on 199 images acquired under unconstrained conditions, belonging to the CASIA-irisV3 database, before and after applying the preprocessing algorithms. Then, the impact of image preprocessing algorithms on the percentage of successful iris segmentation is evaluated by means of a visual inspection of images in order to determine if circumferences of iris and pupil were detected correctly. An increase from 59% to 73% in percentage of successful iris segmentation is obtained with an algorithm that combine elimination of specular reflections, followed by the implementation of a Gaussian filter having a 5x5 kernel. The results highlight the importance of a preprocessing stage as a previous step in order to improve the performance during the edge detection and iris segmentation processes.

  19. Real-time image restoration for iris recognition systems.

    Science.gov (United States)

    Kang, Byung Jun; Park, Kang Ryoung

    2007-12-01

    In the field of biometrics, it has been reported that iris recognition techniques have shown high levels of accuracy because unique patterns of the human iris, which has very many degrees of freedom, are used. However, because conventional iris cameras have small depth-of-field (DOF) areas, input iris images can easily be blurred, which can lead to lower recognition performance, since iris patterns are transformed by the blurring caused by optical defocusing. To overcome these problems, an autofocusing camera can be used. However, this inevitably increases the cost, size, and complexity of the system. Therefore, we propose a new real-time iris image-restoration method, which can increase the camera's DOF without requiring any additional hardware. This paper presents five novelties as compared to previous works: 1) by excluding eyelash and eyelid regions, it is possible to obtain more accurate focus scores from input iris images; 2) the parameter of the point spread function (PSF) can be estimated in terms of camera optics and measured focus scores; therefore, parameter estimation is more accurate than it has been in previous research; 3) because the PSF parameter can be obtained by using a predetermined equation, iris image restoration can be done in real-time; 4) by using a constrained least square (CLS) restoration filter that considers noise, performance can be greatly enhanced; and 5) restoration accuracy can also be enhanced by estimating the weight value of the noise-regularization term of the CLS filter according to the amount of image blurring. Experimental results showed that iris recognition errors when using the proposed restoration method were greatly reduced as compared to those results achieved without restoration or those achieved using previous iris-restoration methods.

  20. Iris image recognition wavelet filter-banks based iris feature extraction schemes

    CERN Document Server

    Rahulkar, Amol D

    2014-01-01

    This book provides the new results in wavelet filter banks based feature extraction, and the classifier in the field of iris image recognition. It provides the broad treatment on the design of separable, non-separable wavelets filter banks, and the classifier. The design techniques presented in the book are applied on iris image analysis for person authentication. This book also brings together the three strands of research (wavelets, iris image analysis, and classifier). It compares the performance of the presented techniques with state-of-the-art available schemes. This book contains the compilation of basic material on the design of wavelets that avoids reading many different books. Therefore, it provide an easier path for the new-comers, researchers to master the contents. In addition, the designed filter banks and classifier can also be effectively used than existing filter-banks in many signal processing applications like pattern classification, data-compression, watermarking, denoising etc.  that will...

  1. The fast iris image clarity evaluation based on Tenengrad and ROI selection

    Science.gov (United States)

    Gao, Shuqin; Han, Min; Cheng, Xu

    2018-04-01

    In iris recognition system, the clarity of iris image is an important factor that influences recognition effect. In the process of recognition, the blurred image may possibly be rejected by the automatic iris recognition system, which will lead to the failure of identification. Therefore it is necessary to evaluate the iris image definition before recognition. Considered the existing evaluation methods on iris image definition, we proposed a fast algorithm to evaluate the definition of iris image in this paper. In our algorithm, firstly ROI (Region of Interest) is extracted based on the reference point which is determined by using the feature of the light spots within the pupil, then Tenengrad operator is used to evaluate the iris image's definition. Experiment results show that, the iris image definition algorithm proposed in this paper could accurately distinguish the iris images of different clarity, and the algorithm has the merit of low computational complexity and more effectiveness.

  2. A fourier transform quality measure for iris images

    CSIR Research Space (South Africa)

    Makinana, S

    2014-08-01

    Full Text Available to ensure that good quality images are selected for feature extraction, in order to improve iris recognition system. In addition, this research proposes a measure of iris image quality using a Fourier Transform. The experimental results demonstrate...

  3. Shape adaptive, robust iris feature extraction from noisy iris images.

    Science.gov (United States)

    Ghodrati, Hamed; Dehghani, Mohammad Javad; Danyali, Habibolah

    2013-10-01

    In the current iris recognition systems, noise removing step is only used to detect noisy parts of the iris region and features extracted from there will be excluded in matching step. Whereas depending on the filter structure used in feature extraction, the noisy parts may influence relevant features. To the best of our knowledge, the effect of noise factors on feature extraction has not been considered in the previous works. This paper investigates the effect of shape adaptive wavelet transform and shape adaptive Gabor-wavelet for feature extraction on the iris recognition performance. In addition, an effective noise-removing approach is proposed in this paper. The contribution is to detect eyelashes and reflections by calculating appropriate thresholds by a procedure called statistical decision making. The eyelids are segmented by parabolic Hough transform in normalized iris image to decrease computational burden through omitting rotation term. The iris is localized by an accurate and fast algorithm based on coarse-to-fine strategy. The principle of mask code generation is to assign the noisy bits in an iris code in order to exclude them in matching step is presented in details. An experimental result shows that by using the shape adaptive Gabor-wavelet technique there is an improvement on the accuracy of recognition rate.

  4. Iris image enhancement for feature recognition and extraction

    CSIR Research Space (South Africa)

    Mabuza, GP

    2012-10-01

    Full Text Available the employment of other algorithms and commands so as to better present and demonstrate the obtained results. Edge detection and enhancing images for use in an iris recognition system allow for efficient recognition and extraction of iris patterns. REFERENCES... Gonzalez, R.C. and Woods, R.E. 2002. Digital Image Processing 2nd Edition, Instructor?s manual .Englewood Cliffs, Prentice Hall, pp 17-36. Proen?a, H. and Alexandre, L.A. 2007. Toward Noncooperative Iris Recognition: A classification approach using...

  5. Iris recognition using image moments and k-means algorithm.

    Science.gov (United States)

    Khan, Yaser Daanial; Khan, Sher Afzal; Ahmad, Farooq; Islam, Saeed

    2014-01-01

    This paper presents a biometric technique for identification of a person using the iris image. The iris is first segmented from the acquired image of an eye using an edge detection algorithm. The disk shaped area of the iris is transformed into a rectangular form. Described moments are extracted from the grayscale image which yields a feature vector containing scale, rotation, and translation invariant moments. Images are clustered using the k-means algorithm and centroids for each cluster are computed. An arbitrary image is assumed to belong to the cluster whose centroid is the nearest to the feature vector in terms of Euclidean distance computed. The described model exhibits an accuracy of 98.5%.

  6. Iris recognition based on key image feature extraction.

    Science.gov (United States)

    Ren, X; Tian, Q; Zhang, J; Wu, S; Zeng, Y

    2008-01-01

    In iris recognition, feature extraction can be influenced by factors such as illumination and contrast, and thus the features extracted may be unreliable, which can cause a high rate of false results in iris pattern recognition. In order to obtain stable features, an algorithm was proposed in this paper to extract key features of a pattern from multiple images. The proposed algorithm built an iris feature template by extracting key features and performed iris identity enrolment. Simulation results showed that the selected key features have high recognition accuracy on the CASIA Iris Set, where both contrast and illumination variance exist.

  7. [Electronic Device for Retinal and Iris Imaging].

    Science.gov (United States)

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  8. Multispectral diagnostic imaging of the iris in pigment dispersion syndrome.

    Science.gov (United States)

    Roberts, Daniel K; Lukic, Ana; Yang, Yongyi; Wilensky, Jacob T; Wernick, Miles N

    2012-08-01

    To determine if wavelength selection with near infrared iris imaging may enhance iris transillumination defects (ITDs) in pigment dispersion syndrome. An experimental apparatus was used to acquire iris images in 6 African-American (AA) and 6 White patients with pigment dispersion syndrome. Light-emitting diode probes of 6 different spectral bands (700 to 950 nm) were used to project light into patients' eyes. Iris patterns were photographed, ITD regions of interest were outlined, and region of interest contrasts were calculated for each spectral band. Contrasts varied as a function of wavelength (Ppigmented eyes may be slightly longer than for less pigmented eyes.

  9. Towards online iris and periocular recognition under relaxed imaging constraints.

    Science.gov (United States)

    Tan, Chun-Wei; Kumar, Ajay

    2013-10-01

    Online iris recognition using distantly acquired images in a less imaging constrained environment requires the development of a efficient iris segmentation approach and recognition strategy that can exploit multiple features available for the potential identification. This paper presents an effective solution toward addressing such a problem. The developed iris segmentation approach exploits a random walker algorithm to efficiently estimate coarsely segmented iris images. These coarsely segmented iris images are postprocessed using a sequence of operations that can effectively improve the segmentation accuracy. The robustness of the proposed iris segmentation approach is ascertained by providing comparison with other state-of-the-art algorithms using publicly available UBIRIS.v2, FRGC, and CASIA.v4-distance databases. Our experimental results achieve improvement of 9.5%, 4.3%, and 25.7% in the average segmentation accuracy, respectively, for the UBIRIS.v2, FRGC, and CASIA.v4-distance databases, as compared with most competing approaches. We also exploit the simultaneously extracted periocular features to achieve significant performance improvement. The joint segmentation and combination strategy suggest promising results and achieve average improvement of 132.3%, 7.45%, and 17.5% in the recognition performance, respectively, from the UBIRIS.v2, FRGC, and CASIA.v4-distance databases, as compared with the related competing approaches.

  10. Reducing Error Rates for Iris Image using higher Contrast in Normalization process

    Science.gov (United States)

    Aminu Ghali, Abdulrahman; Jamel, Sapiee; Abubakar Pindar, Zahraddeen; Hasssan Disina, Abdulkadir; Mat Daris, Mustafa

    2017-08-01

    Iris recognition system is the most secured, and faster means of identification and authentication. However, iris recognition system suffers a setback from blurring, low contrast and illumination due to low quality image which compromises the accuracy of the system. The acceptance or rejection rates of verified user depend solely on the quality of the image. In many cases, iris recognition system with low image contrast could falsely accept or reject user. Therefore this paper adopts Histogram Equalization Technique to address the problem of False Rejection Rate (FRR) and False Acceptance Rate (FAR) by enhancing the contrast of the iris image. A histogram equalization technique enhances the image quality and neutralizes the low contrast of the image at normalization stage. The experimental result shows that Histogram Equalization Technique has reduced FRR and FAR compared to the existing techniques.

  11. Heterogeneous iris image hallucination using sparse representation on a learned heterogeneous patch dictionary

    Science.gov (United States)

    Li, Yung-Hui; Zheng, Bo-Ren; Ji, Dai-Yan; Tien, Chung-Hao; Liu, Po-Tsun

    2014-09-01

    Cross sensor iris matching may seriously degrade the recognition performance because of the sensor mis-match problem of iris images between the enrollment and test stage. In this paper, we propose two novel patch-based heterogeneous dictionary learning method to attack this problem. The first method applies the latest sparse representation theory while the second method tries to learn the correspondence relationship through PCA in heterogeneous patch space. Both methods learn the basic atoms in iris textures across different image sensors and build connections between them. After such connections are built, at test stage, it is possible to hallucinate (synthesize) iris images across different sensors. By matching training images with hallucinated images, the recognition rate can be successfully enhanced. The experimental results showed the satisfied results both visually and in terms of recognition rate. Experimenting with an iris database consisting of 3015 images, we show that the EER is decreased 39.4% relatively by the proposed method.

  12. Multi-image encryption based on synchronization of chaotic lasers and iris authentication

    Science.gov (United States)

    Banerjee, Santo; Mukhopadhyay, Sumona; Rondoni, Lamberto

    2012-07-01

    A new technique of transmitting encrypted combinations of gray scaled and chromatic images using chaotic lasers derived from Maxwell-Bloch's equations has been proposed. This novel scheme utilizes the general method of solution of a set of linear equations to transmit similar sized heterogeneous images which are a combination of monochrome and chromatic images. The chaos encrypted gray scaled images are concatenated along the three color planes resulting in color images. These are then transmitted over a secure channel along with a cover image which is an iris scan. The entire cryptology is augmented with an iris-based authentication scheme. The secret messages are retrieved once the authentication is successful. The objective of our work is briefly outlined as (a) the biometric information is the iris which is encrypted before transmission, (b) the iris is used for personal identification and verifying for message integrity, (c) the information is transmitted securely which are colored images resulting from a combination of gray images, (d) each of the images transmitted are encrypted through chaos based cryptography, (e) these encrypted multiple images are then coupled with the iris through linear combination of images before being communicated over the network. The several layers of encryption together with the ergodicity and randomness of chaos render enough confusion and diffusion properties which guarantee a fool-proof approach in achieving secure communication as demonstrated by exhaustive statistical methods. The result is vital from the perspective of opening a fundamental new dimension in multiplexing and simultaneous transmission of several monochromatic and chromatic images along with biometry based authentication and cryptography.

  13. Iris recognition: on the segmentation of degraded images acquired in the visible wavelength.

    Science.gov (United States)

    Proença, Hugo

    2010-08-01

    Iris recognition imaging constraints are receiving increasing attention. There are several proposals to develop systems that operate in the visible wavelength and in less constrained environments. These imaging conditions engender acquired noisy artifacts that lead to severely degraded images, making iris segmentation a major issue. Having observed that existing iris segmentation methods tend to fail in these challenging conditions, we present a segmentation method that can handle degraded images acquired in less constrained conditions. We offer the following contributions: 1) to consider the sclera the most easily distinguishable part of the eye in degraded images, 2) to propose a new type of feature that measures the proportion of sclera in each direction and is fundamental in segmenting the iris, and 3) to run the entire procedure in deterministically linear time in respect to the size of the image, making the procedure suitable for real-time applications.

  14. Biometric iris image acquisition system with wavefront coding technology

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Yang, Hsi-Wen; Huang, Shao-Hung; Li, Yung-Hui; Tien, Chung-Hao

    2013-09-01

    Biometric signatures for identity recognition have been practiced for centuries. Basically, the personal attributes used for a biometric identification system can be classified into two areas: one is based on physiological attributes, such as DNA, facial features, retinal vasculature, fingerprint, hand geometry, iris texture and so on; the other scenario is dependent on the individual behavioral attributes, such as signature, keystroke, voice and gait style. Among these features, iris recognition is one of the most attractive approaches due to its nature of randomness, texture stability over a life time, high entropy density and non-invasive acquisition. While the performance of iris recognition on high quality image is well investigated, not too many studies addressed that how iris recognition performs subject to non-ideal image data, especially when the data is acquired in challenging conditions, such as long working distance, dynamical movement of subjects, uncontrolled illumination conditions and so on. There are three main contributions in this paper. Firstly, the optical system parameters, such as magnification and field of view, was optimally designed through the first-order optics. Secondly, the irradiance constraints was derived by optical conservation theorem. Through the relationship between the subject and the detector, we could estimate the limitation of working distance when the camera lens and CCD sensor were known. The working distance is set to 3m in our system with pupil diameter 86mm and CCD irradiance 0.3mW/cm2. Finally, We employed a hybrid scheme combining eye tracking with pan and tilt system, wavefront coding technology, filter optimization and post signal recognition to implement a robust iris recognition system in dynamic operation. The blurred image was restored to ensure recognition accuracy over 3m working distance with 400mm focal length and aperture F/6.3 optics. The simulation result as well as experiment validates the proposed code

  15. The infrared imaging spectrograph (IRIS) for TMT: latest science cases and simulations

    Science.gov (United States)

    Wright, Shelley A.; Walth, Gregory; Do, Tuan; Marshall, Daniel; Larkin, James E.; Moore, Anna M.; Adamkovics, Mate; Andersen, David; Armus, Lee; Barth, Aaron; Cote, Patrick; Cooke, Jeff; Chisholm, Eric M.; Davidge, Timothy; Dunn, Jennifer S.; Dumas, Christophe; Ellerbroek, Brent L.; Ghez, Andrea M.; Hao, Lei; Hayano, Yutaka; Liu, Michael; Lopez-Rodriguez, Enrique; Lu, Jessica R.; Mao, Shude; Marois, Christian; Pandey, Shashi B.; Phillips, Andrew C.; Schoeck, Matthias; Subramaniam, Annapurni; Subramanian, Smitha; Suzuki, Ryuji; Tan, Jonathan C.; Terai, Tsuyoshi; Treu, Tommaso; Simard, Luc; Weiss, Jason L.; Wincentsen, James; Wong, Michael; Zhang, Kai

    2016-07-01

    The Thirty Meter Telescope (TMT) first light instrument IRIS (Infrared Imaging Spectrograph) will complete its preliminary design phase in 2016. The IRIS instrument design includes a near-infrared (0.85 - 2.4 micron) integral field spectrograph (IFS) and imager that are able to conduct simultaneous diffraction-limited observations behind the advanced adaptive optics system NFIRAOS. The IRIS science cases have continued to be developed and new science studies have been investigated to aid in technical performance and design requirements. In this development phase, the IRIS science team has paid particular attention to the selection of filters, gratings, sensitivities of the entire system, and science cases that will benefit from the parallel mode of the IFS and imaging camera. We present new science cases for IRIS using the latest end-to-end data simulator on the following topics: Solar System bodies, the Galactic center, active galactic nuclei (AGN), and distant gravitationally-lensed galaxies. We then briefly discuss the necessity of an advanced data management system and data reduction pipeline.

  16. A Novel Edge-Map Creation Approach for Highly Accurate Pupil Localization in Unconstrained Infrared Iris Images

    Directory of Open Access Journals (Sweden)

    Vineet Kumar

    2016-01-01

    Full Text Available Iris segmentation in the iris recognition systems is a challenging task under noncooperative environments. The iris segmentation is a process of detecting the pupil, iris’s outer boundary, and eyelids in the iris image. In this paper, we propose a pupil localization method for locating the pupils in the non-close-up and frontal-view iris images that are captured under near-infrared (NIR illuminations and contain the noise, such as specular and lighting reflection spots, eyeglasses, nonuniform illumination, low contrast, and occlusions by the eyelids, eyelashes, and eyebrow hair. In the proposed method, first, a novel edge-map is created from the iris image, which is based on combining the conventional thresholding and edge detection based segmentation techniques, and then, the general circular Hough transform (CHT is used to find the pupil circle parameters in the edge-map. Our main contribution in this research is a novel edge-map creation technique, which reduces the false edges drastically in the edge-map of the iris image and makes the pupil localization in the noisy NIR images more accurate, fast, robust, and simple. The proposed method was tested with three iris databases: CASIA-Iris-Thousand (version 4.0, CASIA-Iris-Lamp (version 3.0, and MMU (version 2.0. The average accuracy of the proposed method is 99.72% and average time cost per image is 0.727 sec.

  17. Constructing New Biorthogonal Wavelet Type which Matched for Extracting the Iris Image Features

    International Nuclear Information System (INIS)

    Isnanto, R Rizal; Suhardjo; Susanto, Adhi

    2013-01-01

    Some former research have been made for obtaining a new type of wavelet. In case of iris recognition using orthogonal or biorthogonal wavelets, it had been obtained that Haar filter is most suitable to recognize the iris image. However, designing the new wavelet should be done to find a most matched wavelet to extract the iris image features, for which we can easily apply it for identification, recognition, or authentication purposes. In this research, a new biorthogonal wavelet was designed based on Haar filter properties and Haar's orthogonality conditions. As result, it can be obtained a new biorthogonal 5/7 filter type wavelet which has a better than other types of wavelets, including Haar, to extract the iris image features based on its mean-squared error (MSE) and Euclidean distance parameters.

  18. LDPC and SHA based iris recognition for image authentication

    Directory of Open Access Journals (Sweden)

    K. Seetharaman

    2012-11-01

    Full Text Available We introduce a novel way to authenticate an image using Low Density Parity Check (LDPC and Secure Hash Algorithm (SHA based iris recognition method with reversible watermarking scheme, which is based on Integer Wavelet Transform (IWT and threshold embedding technique. The parity checks and parity matrix of LDPC encoding and cancellable biometrics i.e., hash string of unique iris code from SHA-512 are embedded into an image for authentication purpose using reversible watermarking scheme based on IWT and threshold embedding technique. Simply by reversing the embedding process, the original image, parity checks, parity matrix and SHA-512 hash are extracted back from watermarked-image. For authentication, the new hash string produced by employing SHA-512 on error corrected iris code from live person is compared with hash string extracted from watermarked-image. The LDPC code reduces the hamming distance for genuine comparisons by a larger amount than for the impostor comparisons. This results in better separation between genuine and impostor users which improves the authentication performance. Security of this scheme is very high due to the security complexity of SHA-512, which is 2256 under birthday attack. Experimental results show that this approach can assure more accurate authentication with a low false rejection or false acceptance rate and outperforms the prior arts in terms of PSNR.

  19. The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR): A High Speed, Multispectral, Thermal Instrument Development in Support of HyspIRI-TIR

    Science.gov (United States)

    Hook, Simon

    2011-01-01

    The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR) is being developed as part of the risk reduction activities associated with the Hyperspectral Infrared Imager (HyspIRI). The HyspIRI mission was recommended by the National Research Council Decadal Survey and includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. The HyspIRI TIR system will have 60m ground resolution, better than 200mK noise equivalent delta temperature (NEDT), 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. PHyTIR addresses the technology readiness level (TRL) of certain key subsystems of the TIR imager, primarily the detector assembly and scanning mechanism. PHyTIR will use Mercury Cadmium Telluride (MCT) technology at the focal plane and operate in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence allowing the high data rates needed for the 5 day repeat. PHyTIR will also demonstrate a newly developed interferometeric metrology system. This system will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing post-processing (e.g. geo-rectification computations).

  20. Comparative analysis of classification based algorithms for diabetes diagnosis using iris images.

    Science.gov (United States)

    Samant, Piyush; Agarwal, Ravinder

    2018-01-01

    Photo-diagnosis is always an intriguing area for the researchers, with the advancement of image processing and computer machine vision techniques it have become more reliable and popular in recent years. The objective of this paper is to study the change in the features of iris, particularly irregularities in the pigmentation of certain areas of the iris with respect to diabetic health of an individual. Apart from the point that iris recognition concentrates on the overall structure of the iris, diagnostic techniques emphasises the local variations in the particular area of iris. Pre-image processing techniques have been applied to extract iris and thereafter, region of interest from the extracted iris have been cropped out. In order to observe the changes in the tissue pigmentation of region of interest, statistical, texture textural and wavelet features have been extracted. At the end, a comparison of accuracies of five different classifiers has been presented to classify two subject groups of diabetic and non-diabetic. Best classification accuracy has been calculated as 89.66% by the random forest classifier. Results have been shown the effectiveness and diagnostic significance of the proposed methodology. Presented piece of work offers a novel systemic perspective of non-invasive and automatic diabetic diagnosis.

  1. Unconstrained Iris Acquisition and Recognition Using COTS PTZ Camera

    Directory of Open Access Journals (Sweden)

    Venugopalan Shreyas

    2010-01-01

    Full Text Available Abstract Uniqueness of iris patterns among individuals has resulted in the ubiquity of iris recognition systems in virtual and physical spaces, at high security facilities around the globe. Traditional methods of acquiring iris patterns in commercial systems scan the iris when an individual is at a predetermined location in front of the scanner. Most state-of-the-art techniques for unconstrained iris acquisition in literature use expensive custom equipment and are composed of a multicamera setup, which is bulky, expensive, and requires calibration. This paper investigates a method of unconstrained iris acquisition and recognition using a single commercial off-the-shelf (COTS pan-tilt-zoom (PTZ camera, that is compact and that reduces the cost of the final system, compared to other proposed hierarchical multicomponent systems. We employ state-of-the-art techniques for face detection and a robust eye detection scheme using active shape models for accurate landmark localization. Additionally, our system alleviates the need for any calibration stage prior to its use. We present results using a database of iris images captured using our system, while operating in an unconstrained acquisition mode at 1.5 m standoff, yielding an iris diameter in the 150–200 pixels range.

  2. Ordinal measures for iris recognition.

    Science.gov (United States)

    Sun, Zhenan; Tan, Tieniu

    2009-12-01

    Images of a human iris contain rich texture information useful for identity authentication. A key and still open issue in iris recognition is how best to represent such textural information using a compact set of features (iris features). In this paper, we propose using ordinal measures for iris feature representation with the objective of characterizing qualitative relationships between iris regions rather than precise measurements of iris image structures. Such a representation may lose some image-specific information, but it achieves a good trade-off between distinctiveness and robustness. We show that ordinal measures are intrinsic features of iris patterns and largely invariant to illumination changes. Moreover, compactness and low computational complexity of ordinal measures enable highly efficient iris recognition. Ordinal measures are a general concept useful for image analysis and many variants can be derived for ordinal feature extraction. In this paper, we develop multilobe differential filters to compute ordinal measures with flexible intralobe and interlobe parameters such as location, scale, orientation, and distance. Experimental results on three public iris image databases demonstrate the effectiveness of the proposed ordinal feature models.

  3. Hyperspectral optical imaging of human iris in vivo: characteristics of reflectance spectra

    Science.gov (United States)

    Medina, José M.; Pereira, Luís M.; Correia, Hélder T.; Nascimento, Sérgio M. C.

    2011-07-01

    We report a hyperspectral imaging system to measure the reflectance spectra of real human irises with high spatial resolution. A set of ocular prosthesis was used as the control condition. Reflectance data were decorrelated by the principal-component analysis. The main conclusion is that spectral complexity of the human iris is considerable: between 9 and 11 principal components are necessary to account for 99% of the cumulative variance in human irises. Correcting image misalignments associated with spontaneous ocular movements did not influence this result. The data also suggests a correlation between the first principal component and different levels of melanin present in the irises. It was also found that although the spectral characteristics of the first five principal components were not affected by the radial and angular position of the selected iridal areas, they affect the higher-order ones, suggesting a possible influence of the iris texture. The results show that hyperspectral imaging in the iris, together with adequate spectroscopic analyses provide more information than conventional colorimetric methods, making hyperspectral imaging suitable for the characterization of melanin and the noninvasive diagnosis of ocular diseases and iris color.

  4. IrisDenseNet: Robust Iris Segmentation Using Densely Connected Fully Convolutional Networks in the Images by Visible Light and Near-Infrared Light Camera Sensors.

    Science.gov (United States)

    Arsalan, Muhammad; Naqvi, Rizwan Ali; Kim, Dong Seop; Nguyen, Phong Ha; Owais, Muhammad; Park, Kang Ryoung

    2018-05-10

    The recent advancements in computer vision have opened new horizons for deploying biometric recognition algorithms in mobile and handheld devices. Similarly, iris recognition is now much needed in unconstraint scenarios with accuracy. These environments make the acquired iris image exhibit occlusion, low resolution, blur, unusual glint, ghost effect, and off-angles. The prevailing segmentation algorithms cannot cope with these constraints. In addition, owing to the unavailability of near-infrared (NIR) light, iris recognition in visible light environment makes the iris segmentation challenging with the noise of visible light. Deep learning with convolutional neural networks (CNN) has brought a considerable breakthrough in various applications. To address the iris segmentation issues in challenging situations by visible light and near-infrared light camera sensors, this paper proposes a densely connected fully convolutional network (IrisDenseNet), which can determine the true iris boundary even with inferior-quality images by using better information gradient flow between the dense blocks. In the experiments conducted, five datasets of visible light and NIR environments were used. For visible light environment, noisy iris challenge evaluation part-II (NICE-II selected from UBIRIS.v2 database) and mobile iris challenge evaluation (MICHE-I) datasets were used. For NIR environment, the institute of automation, Chinese academy of sciences (CASIA) v4.0 interval, CASIA v4.0 distance, and IIT Delhi v1.0 iris datasets were used. Experimental results showed the optimal segmentation of the proposed IrisDenseNet and its excellent performance over existing algorithms for all five datasets.

  5. IrisDenseNet: Robust Iris Segmentation Using Densely Connected Fully Convolutional Networks in the Images by Visible Light and Near-Infrared Light Camera Sensors

    Directory of Open Access Journals (Sweden)

    Muhammad Arsalan

    2018-05-01

    Full Text Available The recent advancements in computer vision have opened new horizons for deploying biometric recognition algorithms in mobile and handheld devices. Similarly, iris recognition is now much needed in unconstraint scenarios with accuracy. These environments make the acquired iris image exhibit occlusion, low resolution, blur, unusual glint, ghost effect, and off-angles. The prevailing segmentation algorithms cannot cope with these constraints. In addition, owing to the unavailability of near-infrared (NIR light, iris recognition in visible light environment makes the iris segmentation challenging with the noise of visible light. Deep learning with convolutional neural networks (CNN has brought a considerable breakthrough in various applications. To address the iris segmentation issues in challenging situations by visible light and near-infrared light camera sensors, this paper proposes a densely connected fully convolutional network (IrisDenseNet, which can determine the true iris boundary even with inferior-quality images by using better information gradient flow between the dense blocks. In the experiments conducted, five datasets of visible light and NIR environments were used. For visible light environment, noisy iris challenge evaluation part-II (NICE-II selected from UBIRIS.v2 database and mobile iris challenge evaluation (MICHE-I datasets were used. For NIR environment, the institute of automation, Chinese academy of sciences (CASIA v4.0 interval, CASIA v4.0 distance, and IIT Delhi v1.0 iris datasets were used. Experimental results showed the optimal segmentation of the proposed IrisDenseNet and its excellent performance over existing algorithms for all five datasets.

  6. The Infrared Imaging Spectrograph (IRIS) for TMT: multi-tiered wavefront measurements and novel mechanical design

    Science.gov (United States)

    Dunn, Jennifer; Andersen, David; Chapin, Edward; Reshetov, Vlad; Wierzbicki, Ramunas; Herriot, Glen; Chalmer, Dean; Isbrucker, Victor; Larkin, James E.; Moore, Anna M.; Suzuki, Ryuji

    2016-08-01

    The InfraRed Imaging Spectrograph (IRIS) will be the first light adaptive optics instrument on the Thirty Meter Telescope (TMT). IRIS is being built by a collaboration between Caltech, the University of California, NAOJ and NRC Herzberg. In this paper we present novel aspects of the Support Structure, Rotator and On-Instrument Wavefront Sensor systems being developed at NRC Herzberg. IRIS is suspended from the bottom port of the Narrow Field Infrared Adaptive Optics System (NFIRAOS), and provides its own image de-rotation to compensate for sidereal rotation of the focal plane. This arrangement is a challenge because NFIRAOS is designed to host two other science instruments, which imposes strict mass requirements on IRIS. As the mechanical design of all elements has progressed, we have been tasked with keeping the instrument mass under seven tonnes. This requirement has resulted in a mass reduction of 30 percent for the support structure and rotator compared to the most recent IRIS designs. To accomplish this goal, while still being able to withstand earthquakes, we developed a new design with composite materials. As IRIS is a client instrument of NFIRAOS, it benefits from NFIRAOS's superior AO correction. IRIS plays an important role in providing this correction by sensing low-order aberrations with three On-Instrument Wavefront Sensors (OIWFS). The OIWFS consists of three independently positioned natural guide star wavefront sensor probe arms that patrol a 2-arcminute field of view. We expect tip-tilt measurements from faint stars within the IRIS imager focal plane will further stabilize the delivered image quality. We describe how the use of On-Detector Guide Windows (ODGWs) in the IRIS imaging detector can be incorporated into the AO correction. In this paper, we present our strategies for acquiring and tracking sources with this complex AO system, and for mitigating and measuring the various potential sources of image blur and misalignment due to properties of

  7. Toward accurate and fast iris segmentation for iris biometrics.

    Science.gov (United States)

    He, Zhaofeng; Tan, Tieniu; Sun, Zhenan; Qiu, Xianchao

    2009-09-01

    Iris segmentation is an essential module in iris recognition because it defines the effective image region used for subsequent processing such as feature extraction. Traditional iris segmentation methods often involve an exhaustive search of a large parameter space, which is time consuming and sensitive to noise. To address these problems, this paper presents a novel algorithm for accurate and fast iris segmentation. After efficient reflection removal, an Adaboost-cascade iris detector is first built to extract a rough position of the iris center. Edge points of iris boundaries are then detected, and an elastic model named pulling and pushing is established. Under this model, the center and radius of the circular iris boundaries are iteratively refined in a way driven by the restoring forces of Hooke's law. Furthermore, a smoothing spline-based edge fitting scheme is presented to deal with noncircular iris boundaries. After that, eyelids are localized via edge detection followed by curve fitting. The novelty here is the adoption of a rank filter for noise elimination and a histogram filter for tackling the shape irregularity of eyelids. Finally, eyelashes and shadows are detected via a learned prediction model. This model provides an adaptive threshold for eyelash and shadow detection by analyzing the intensity distributions of different iris regions. Experimental results on three challenging iris image databases demonstrate that the proposed algorithm outperforms state-of-the-art methods in both accuracy and speed.

  8. A Novel Iris Segmentation Scheme

    Directory of Open Access Journals (Sweden)

    Chen-Chung Liu

    2014-01-01

    Full Text Available One of the key steps in the iris recognition system is the accurate iris segmentation from its surrounding noises including pupil, sclera, eyelashes, and eyebrows of a captured eye-image. This paper presents a novel iris segmentation scheme which utilizes the orientation matching transform to outline the outer and inner iris boundaries initially. It then employs Delogne-Kåsa circle fitting (instead of the traditional Hough transform to further eliminate the outlier points to extract a more precise iris area from an eye-image. In the extracted iris region, the proposed scheme further utilizes the differences in the intensity and positional characteristics of the iris, eyelid, and eyelashes to detect and delete these noises. The scheme is then applied on iris image database, UBIRIS.v1. The experimental results show that the presented scheme provides a more effective and efficient iris segmentation than other conventional methods.

  9. The Design of a Single-Bit CMOS Image Sensor for Iris Recognition Applications

    Directory of Open Access Journals (Sweden)

    Keunyeol Park

    2018-02-01

    Full Text Available This paper presents a single-bit CMOS image sensor (CIS that uses a data processing technique with an edge detection block for simple iris segmentation. In order to recognize the iris image, the image sensor conventionally captures high-resolution image data in digital code, extracts the iris data, and then compares it with a reference image through a recognition algorithm. However, in this case, the frame rate decreases by the time required for digital signal conversion of multi-bit digital data through the analog-to-digital converter (ADC in the CIS. In order to reduce the overall processing time as well as the power consumption, we propose a data processing technique with an exclusive OR (XOR logic gate to obtain single-bit and edge detection image data instead of multi-bit image data through the ADC. In addition, we propose a logarithmic counter to efficiently measure single-bit image data that can be applied to the iris recognition algorithm. The effective area of the proposed single-bit image sensor (174 × 144 pixel is 2.84 mm2 with a 0.18 μm 1-poly 4-metal CMOS image sensor process. The power consumption of the proposed single-bit CIS is 2.8 mW with a 3.3 V of supply voltage and 520 frame/s of the maximum frame rates. The error rate of the ADC is 0.24 least significant bit (LSB on an 8-bit ADC basis at a 50 MHz sampling frequency.

  10. The Design of a Single-Bit CMOS Image Sensor for Iris Recognition Applications.

    Science.gov (United States)

    Park, Keunyeol; Song, Minkyu; Kim, Soo Youn

    2018-02-24

    This paper presents a single-bit CMOS image sensor (CIS) that uses a data processing technique with an edge detection block for simple iris segmentation. In order to recognize the iris image, the image sensor conventionally captures high-resolution image data in digital code, extracts the iris data, and then compares it with a reference image through a recognition algorithm. However, in this case, the frame rate decreases by the time required for digital signal conversion of multi-bit digital data through the analog-to-digital converter (ADC) in the CIS. In order to reduce the overall processing time as well as the power consumption, we propose a data processing technique with an exclusive OR (XOR) logic gate to obtain single-bit and edge detection image data instead of multi-bit image data through the ADC. In addition, we propose a logarithmic counter to efficiently measure single-bit image data that can be applied to the iris recognition algorithm. The effective area of the proposed single-bit image sensor (174 × 144 pixel) is 2.84 mm² with a 0.18 μm 1-poly 4-metal CMOS image sensor process. The power consumption of the proposed single-bit CIS is 2.8 mW with a 3.3 V of supply voltage and 520 frame/s of the maximum frame rates. The error rate of the ADC is 0.24 least significant bit (LSB) on an 8-bit ADC basis at a 50 MHz sampling frequency.

  11. Iris Matching Based on Personalized Weight Map.

    Science.gov (United States)

    Dong, Wenbo; Sun, Zhenan; Tan, Tieniu

    2011-09-01

    Iris recognition typically involves three steps, namely, iris image preprocessing, feature extraction, and feature matching. The first two steps of iris recognition have been well studied, but the last step is less addressed. Each human iris has its unique visual pattern and local image features also vary from region to region, which leads to significant differences in robustness and distinctiveness among the feature codes derived from different iris regions. However, most state-of-the-art iris recognition methods use a uniform matching strategy, where features extracted from different regions of the same person or the same region for different individuals are considered to be equally important. This paper proposes a personalized iris matching strategy using a class-specific weight map learned from the training images of the same iris class. The weight map can be updated online during the iris recognition procedure when the successfully recognized iris images are regarded as the new training data. The weight map reflects the robustness of an encoding algorithm on different iris regions by assigning an appropriate weight to each feature code for iris matching. Such a weight map trained by sufficient iris templates is convergent and robust against various noise. Extensive and comprehensive experiments demonstrate that the proposed personalized iris matching strategy achieves much better iris recognition performance than uniform strategies, especially for poor quality iris images.

  12. A gallery approach for off-angle iris recognition

    Science.gov (United States)

    Karakaya, Mahmut; Yoldash, Rashiduddin; Boehnen, Christopher

    2015-05-01

    It has been proven that hamming distance score between frontal and off-angle iris images of same eye differs in iris recognition system. The distinction of hamming distance score is caused by many factors such as image acquisition angle, occlusion, pupil dilation, and limbus effect. In this paper, we first study the effect of the angle variations between iris plane and the image acquisition systems. We present how hamming distance changes for different off-angle iris images even if they are coming from the same iris. We observe that increment in acquisition angle of compared iris images causes the increment in hamming distance. Second, we propose a new technique in off-angle iris recognition system that includes creating a gallery of different off-angle iris images (such as, 0, 10, 20, 30, 40, and 50 degrees) and comparing each probe image with these gallery images. We will show the accuracy of the gallery approach for off-angle iris recognition.

  13. Locating An IRIS From Image Using Canny And Hough Transform

    Directory of Open Access Journals (Sweden)

    Poorvi Bhatt

    2017-11-01

    Full Text Available Iris recognition a relatively new biometric technology has great advantages such as variability stability and security thus it is the most promising for high security environments. The proposed system here is a simple system design and implemented to find the iris from the image using Hough Transform Algorithm. Canny Edge detector has been used to get edge image to use it as an input to the Hough Transform. To get the general idea of Hough Transform the Hough Transform for circle is also implemented. RGB value of 3-D accumulator array of peaks of inner circle and outer circle has been performed. And at the end some suggestions are made to improve the system and performance gets discussed.

  14. Improved iris localization by using wide and narrow field of view cameras for iris recognition

    Science.gov (United States)

    Kim, Yeong Gon; Shin, Kwang Yong; Park, Kang Ryoung

    2013-10-01

    Biometrics is a method of identifying individuals by their physiological or behavioral characteristics. Among other biometric identifiers, iris recognition has been widely used for various applications that require a high level of security. When a conventional iris recognition camera is used, the size and position of the iris region in a captured image vary according to the X, Y positions of a user's eye and the Z distance between a user and the camera. Therefore, the searching area of the iris detection algorithm is increased, which can inevitably decrease both the detection speed and accuracy. To solve these problems, we propose a new method of iris localization that uses wide field of view (WFOV) and narrow field of view (NFOV) cameras. Our study is new as compared to previous studies in the following four ways. First, the device used in our research acquires three images, one each of the face and both irises, using one WFOV and two NFOV cameras simultaneously. The relation between the WFOV and NFOV cameras is determined by simple geometric transformation without complex calibration. Second, the Z distance (between a user's eye and the iris camera) is estimated based on the iris size in the WFOV image and anthropometric data of the size of the human iris. Third, the accuracy of the geometric transformation between the WFOV and NFOV cameras is enhanced by using multiple matrices of the transformation according to the Z distance. Fourth, the searching region for iris localization in the NFOV image is significantly reduced based on the detected iris region in the WFOV image and the matrix of geometric transformation corresponding to the estimated Z distance. Experimental results showed that the performance of the proposed iris localization method is better than that of conventional methods in terms of accuracy and processing time.

  15. [Surgical treatment with an artificial iris].

    Science.gov (United States)

    Mayer, C S; Hoffmann, A E

    2015-10-01

    Iris defects with their disturbed pupillary function, visual impairment and glare constitute a therapeutic challenge in surgical reconstruction. A new therapeutic option for distinctive defects consists in the implantation of a custom-made silicone iris. This new and challenging therapy provides the opportunity to achieve an individual, aesthetically appealing and good functional result for the patient.

  16. Measuring Biometric Sample Quality in terms of Biometric Feature Information in Iris Images

    Directory of Open Access Journals (Sweden)

    R. Youmaran

    2012-01-01

    Full Text Available This paper develops an approach to measure the information content in a biometric feature representation of iris images. In this context, the biometric feature information is calculated using the relative entropy between the intraclass and interclass feature distributions. The collected data is regularized using a Gaussian model of the feature covariances in order to practically measure the biometric information with limited data samples. An example of this method is shown for iris templates processed using Principal-Component Analysis- (PCA- and Independent-Component Analysis- (ICA- based feature decomposition schemes. From this, the biometric feature information is calculated to be approximately 278 bits for PCA and 288 bits for ICA iris features using Masek's iris recognition scheme. This value approximately matches previous estimates of iris information content.

  17. The UBIRIS.v2: a database of visible wavelength iris images captured on-the-move and at-a-distance.

    Science.gov (United States)

    Proença, Hugo; Filipe, Sílvio; Santos, Ricardo; Oliveira, João; Alexandre, Luís A

    2010-08-01

    The iris is regarded as one of the most useful traits for biometric recognition and the dissemination of nationwide iris-based recognition systems is imminent. However, currently deployed systems rely on heavy imaging constraints to capture near infrared images with enough quality. Also, all of the publicly available iris image databases contain data correspondent to such imaging constraints and therefore are exclusively suitable to evaluate methods thought to operate on these type of environments. The main purpose of this paper is to announce the availability of the UBIRIS.v2 database, a multisession iris images database which singularly contains data captured in the visible wavelength, at-a-distance (between four and eight meters) and on on-the-move. This database is freely available for researchers concerned about visible wavelength iris recognition and will be useful in accessing the feasibility and specifying the constraints of this type of biometric recognition.

  18. Off-Angle Iris Correction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Thompson, Joseph T [ORNL; Karakaya, Mahmut [ORNL; Boehnen, Chris Bensing [ORNL

    2016-01-01

    In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

  19. On techniques for angle compensation in nonideal iris recognition.

    Science.gov (United States)

    Schuckers, Stephanie A C; Schmid, Natalia A; Abhyankar, Aditya; Dorairaj, Vivekanand; Boyce, Christopher K; Hornak, Lawrence A

    2007-10-01

    The popularity of the iris biometric has grown considerably over the past two to three years. Most research has been focused on the development of new iris processing and recognition algorithms for frontal view iris images. However, a few challenging directions in iris research have been identified, including processing of a nonideal iris and iris at a distance. In this paper, we describe two nonideal iris recognition systems and analyze their performance. The word "nonideal" is used in the sense of compensating for off-angle occluded iris images. The system is designed to process nonideal iris images in two steps: 1) compensation for off-angle gaze direction and 2) processing and encoding of the rotated iris image. Two approaches are presented to account for angular variations in the iris images. In the first approach, we use Daugman's integrodifferential operator as an objective function to estimate the gaze direction. After the angle is estimated, the off-angle iris image undergoes geometric transformations involving the estimated angle and is further processed as if it were a frontal view image. The encoding technique developed for a frontal image is based on the application of the global independent component analysis. The second approach uses an angular deformation calibration model. The angular deformations are modeled, and calibration parameters are calculated. The proposed method consists of a closed-form solution, followed by an iterative optimization procedure. The images are projected on the plane closest to the base calibrated plane. Biorthogonal wavelets are used for encoding to perform iris recognition. We use a special dataset of the off-angle iris images to quantify the performance of the designed systems. A series of receiver operating characteristics demonstrate various effects on the performance of the nonideal-iris-based recognition system.

  20. Scheimpflug with computational imaging to extend the depth of field of iris recognition systems

    Science.gov (United States)

    Sinharoy, Indranil

    Despite the enormous success of iris recognition in close-range and well-regulated spaces for biometric authentication, it has hitherto failed to gain wide-scale adoption in less controlled, public environments. The problem arises from a limitation in imaging called the depth of field (DOF): the limited range of distances beyond which subjects appear blurry in the image. The loss of spatial details in the iris image outside the small DOF limits the iris image capture to a small volume-the capture volume. Existing techniques to extend the capture volume are usually expensive, computationally intensive, or afflicted by noise. Is there a way to combine the classical Scheimpflug principle with the modern computational imaging techniques to extend the capture volume? The solution we found is, surprisingly, simple; yet, it provides several key advantages over existing approaches. Our method, called Angular Focus Stacking (AFS), consists of capturing a set of images while rotating the lens, followed by registration, and blending of the in-focus regions from the images in the stack. The theoretical underpinnings of AFS arose from a pair of new and general imaging models we developed for Scheimpflug imaging that directly incorporates the pupil parameters. The model revealed that we could register the images in the stack analytically if we pivot the lens at the center of its entrance pupil, rendering the registration process exact. Additionally, we found that a specific lens design further reduces the complexity of image registration making AFS suitable for real-time performance. We have demonstrated up to an order of magnitude improvement in the axial capture volume over conventional image capture without sacrificing optical resolution and signal-to-noise ratio. The total time required for capturing the set of images for AFS is less than the time needed for a single-exposure, conventional image for the same DOF and brightness level. The net reduction in capture time can

  1. Waardenburg syndrome: iris and choroidal hypopigmentation: findings on anterior and posterior segment imaging.

    Science.gov (United States)

    Shields, Carol L; Nickerson, Stephanie J; Al-Dahmash, Saad; Shields, Jerry A

    2013-09-01

    Waardenburg syndrome typically manifests with congenital iris pigmentary abnormalities, but careful inspection can reveal additional posterior uveal pigmentary abnormalities. To demonstrate iris and choroidal hypopigmentation in patients with Waardenburg syndrome. Retrospective review of 7 patients referred for evaluation of presumed ocular melanocytosis. To describe the clinical and imaging features of the anterior and posterior uvea. In all patients, the diagnosis of Waardenburg syndrome was established. The nonocular features included white forelock in 4 of 7 (57%), tubular nose in 5 of 6 (83%), and small nasal alae in 5 of 6 (83%) patients. In 2 patients, a hearing deficit was documented on audiology testing. Family history of Waardenburg syndrome was elicited in 5 of 7 (71%) patients. Ocular features (7 patients) included telecanthus in 5 (71%), synophrys in 2 (29%), iris hypopigmentation in 5 (71%), and choroidal hypopigmentation in 5 (71%) patients. No patient had muscle contractures or Hirschsprung disease. Visual acuity was 20/20 to 20/50 in all patients. Iris hypopigmentation in 8 eyes was sector in 6 (75%) and diffuse (complete) in 2 (25%). Choroidal hypopigmentation in 9 eyes (100%) showed a sector pattern in 6 (67%) and a diffuse pattern in 3 (33%). Anterior segment optical coherence tomography revealed the hypopigmented iris to be thinner and with shallower crypts than the normal iris. Posterior segment optical coherence tomography showed a normal retina in all patients, but the subfoveal choroid in the hypopigmented region was slightly thinner (mean, 197 μm) compared with the opposite normal choroid (243 μm). Fundus autofluorescence demonstrated mild hyperautofluorescence (scleral unmasking) in hypopigmented choroid and no lipofuscin abnormality. Waardenburg syndrome manifests hypopigmentation of the iris and choroid with imaging features showing a slight reduction in the thickness of the affected tissue.

  2. The Influence Of Customer Handling On Brand Image In Building Customer Loyalty

    Directory of Open Access Journals (Sweden)

    Ryan Kurniawan

    2015-08-01

    Full Text Available Complaint handling influences brand image which will influence customer loyalty in the future. This research is aimed to find out how the complaint handling is capable to influence against the brand image in building the customer loyalty of Indomaret Minimarket with the study case of Indomaret Minimarket. This research also aims to find out how the complaint handling is conducted by Indomaret Minimarket the brand image of service on Indomaret Minimarket as well as the customer loyalty of Indomaret Minimarket. This research using questionnaire as an instrument in collecting the data. The analysis type of this research is descriptive analysis and causal. The sample used as many as a 165 respondents with purposive sampling techniques. This research uses 33 indicators that will be counted with analysis technique SEM Structural Equation Modelling. The result of this research is that the complaint handling conducted by Indomaret Minimarket has been good but the aspect of speed in complaint handling is considered as not good. Besides the brand image and loyalty have been good enough. The customer loyalty is influenced by the complaint handling and the brand image by 32.7. The complaint handling has a significant influence against the customer satisfaction but the complaint handling does not influence against the customer loyalty. The brand image significantly influences against the customer loyalty. Then complaint handling influential not directly to customers trough loyalty of customer satisfaction. In addition the necessary integrated system standardization compensation and to rejuvenate issue at regular intervals to improve complaint handling that can give the effect to customer loyalty through brand image.

  3. Comparison and evaluation of datasets for off-angle iris recognition

    Science.gov (United States)

    Kurtuncu, Osman M.; Cerme, Gamze N.; Karakaya, Mahmut

    2016-05-01

    In this paper, we investigated the publicly available iris recognition datasets and their data capture procedures in order to determine if they are suitable for the stand-off iris recognition research. Majority of the iris recognition datasets include only frontal iris images. Even if a few datasets include off-angle iris images, the frontal and off-angle iris images are not captured at the same time. The comparison of the frontal and off-angle iris images shows not only differences in the gaze angle but also change in pupil dilation and accommodation as well. In order to isolate the effect of the gaze angle from other challenging issues including dilation and accommodation, the frontal and off-angle iris images are supposed to be captured at the same time by using two different cameras. Therefore, we developed an iris image acquisition platform by using two cameras in this work where one camera captures frontal iris image and the other one captures iris images from off-angle. Based on the comparison of Hamming distance between frontal and off-angle iris images captured with the two-camera- setup and one-camera-setup, we observed that Hamming distance in two-camera-setup is less than one-camera-setup ranging from 0.05 to 0.001. These results show that in order to have accurate results in the off-angle iris recognition research, two-camera-setup is necessary in order to distinguish the challenging issues from each other.

  4. Nonintrusive iris image acquisition system based on a pan-tilt-zoom camera and light stripe projection

    Science.gov (United States)

    Yoon, Soweon; Jung, Ho Gi; Park, Kang Ryoung; Kim, Jaihie

    2009-03-01

    Although iris recognition is one of the most accurate biometric technologies, it has not yet been widely used in practical applications. This is mainly due to user inconvenience during the image acquisition phase. Specifically, users try to adjust their eye position within small capture volume at a close distance from the system. To overcome these problems, we propose a novel iris image acquisition system that provides users with unconstrained environments: a large operating range, enabling movement from standing posture, and capturing good-quality iris images in an acceptable time. The proposed system has the following three contributions compared with previous works: (1) the capture volume is significantly increased by using a pan-tilt-zoom (PTZ) camera guided by a light stripe projection, (2) the iris location in the large capture volume is found fast due to 1-D vertical face searching from the user's horizontal position obtained by the light stripe projection, and (3) zooming and focusing on the user's irises at a distance are accurate and fast using the estimated 3-D position of a face by the light stripe projection and the PTZ camera. Experimental results show that the proposed system can capture good-quality iris images in 2.479 s on average at a distance of 1.5 to 3 m, while allowing a limited amount of movement by the user.

  5. Iris Recognition Using Wavelet

    Directory of Open Access Journals (Sweden)

    Khaliq Masood

    2013-08-01

    Full Text Available Biometric systems are getting more attention in the present era. Iris recognition is one of the most secure and authentic among the other biometrics and this field demands more authentic, reliable and fast algorithms to implement these biometric systems in real time. In this paper, an efficient localization technique is presented to identify pupil and iris boundaries using histogram of the iris image. Two small portions of iris have been used for polar transformation to reduce computational time and to increase the efficiency of the system. Wavelet transform is used for feature vector generation. Rotation of iris is compensated without shifts in the iris code. System is tested on Multimedia University Iris Database and results show that proposed system has encouraging performance.

  6. A novel iris transillumination grading scale allowing flexible assessment with quantitative image analysis and visual matching.

    Science.gov (United States)

    Wang, Chen; Brancusi, Flavia; Valivullah, Zaheer M; Anderson, Michael G; Cunningham, Denise; Hedberg-Buenz, Adam; Power, Bradley; Simeonov, Dimitre; Gahl, William A; Zein, Wadih M; Adams, David R; Brooks, Brian

    2018-01-01

    To develop a sensitive scale of iris transillumination suitable for clinical and research use, with the capability of either quantitative analysis or visual matching of images. Iris transillumination photographic images were used from 70 study subjects with ocular or oculocutaneous albinism. Subjects represented a broad range of ocular pigmentation. A subset of images was subjected to image analysis and ranking by both expert and nonexpert reviewers. Quantitative ordering of images was compared with ordering by visual inspection. Images were binned to establish an 8-point scale. Ranking consistency was evaluated using the Kendall rank correlation coefficient (Kendall's tau). Visual ranking results were assessed using Kendall's coefficient of concordance (Kendall's W) analysis. There was a high degree of correlation among the image analysis, expert-based and non-expert-based image rankings. Pairwise comparisons of the quantitative ranking with each reviewer generated an average Kendall's tau of 0.83 ± 0.04 (SD). Inter-rater correlation was also high with Kendall's W of 0.96, 0.95, and 0.95 for nonexpert, expert, and all reviewers, respectively. The current standard for assessing iris transillumination is expert assessment of clinical exam findings. We adapted an image-analysis technique to generate quantitative transillumination values. Quantitative ranking was shown to be highly similar to a ranking produced by both expert and nonexpert reviewers. This finding suggests that the image characteristics used to quantify iris transillumination do not require expert interpretation. Inter-rater rankings were also highly similar, suggesting that varied methods of transillumination ranking are robust in terms of producing reproducible results.

  7. Computational cameras for moving iris recognition

    Science.gov (United States)

    McCloskey, Scott; Venkatesha, Sharath

    2015-05-01

    Iris-based biometric identification is increasingly used for facility access and other security applications. Like all methods that exploit visual information, however, iris systems are limited by the quality of captured images. Optical defocus due to a small depth of field (DOF) is one such challenge, as is the acquisition of sharply-focused iris images from subjects in motion. This manuscript describes the application of computational motion-deblurring cameras to the problem of moving iris capture, from the underlying theory to system considerations and performance data.

  8. Optical Coherence Tomography Angiography Characteristics of Iris Melanocytic Tumors

    Science.gov (United States)

    Skalet, Alison H.; Li, Yan; Lu, Chen D.; Jia, Yali; Lee, ByungKun; Husvogt, Lennart; Maier, Andreas; Fujimoto, James G.; Thomas, Charles R.; Huang, David

    2016-01-01

    Objective To evaluate tumor vasculature with optical coherence tomography (OCT) angiography (OCTA) in malignant iris melanomas and benign iris lesions. Design Cross-sectional observational clinical study. Participants Patients with iris lesions and healthy volunteers. Methods Eyes were imaged using OCTA systems operating at 1050 and 840 nm wavelengths. Three-dimensional OCTA scans were acquired. Iris melanomas patients treated with radiation therapy were imaged again after I-125 plaque brachytherapy at 6 and 18 months. Main Outcome Measures OCT and OCTA images, qualitative evaluation of iris and tumor vasculature and quantitative vessel density. Results One eye each of eight normal volunteers and nine patients with iris melanomas or benign iris lesions including freckles, nevi, and an iris pigment epithelial (IPE) cyst were imaged. The normal iris has radially-oriented vessels within the stroma on OCTA. Penetration of flow signal in normal iris depended on iris color, with best penetration seen in light to moderately pigmented irides. Iris melanomas demonstrated tortuous and disorganized intratumoral vasculature. In two eyes with nevi there was no increased vascularity; in another, fine vascular loops were noted near an area of ectropion uveae. Iris freckles and the IPE cyst did not have intrinsic vascularity. The vessel density was significantly higher within iris melanomas (34.5%±9.8%, piris nevi (8.0%±1.4%) or normal irides (8.0%±1.2%). Tumor regression after radiation therapy for melanomas was associated with decreased vessel density. OCTA at 1050 nm provided better visualization of tumor vasculature and penetration through thicker tumors than at 840 nm. But in very thick tumors and highly pigmented lesions even 1050 nm OCTA could not visualize their full thickness. Interpretable OCTA images were obtained in 82% participants in whom imaging was attempted. Conclusions This is the first demonstration of OCTA in iris tumors. OCTA may provide a dye-free, no

  9. The Influence Of Customer Handling On Brand Image In Building Customer Loyalty

    OpenAIRE

    Ryan Kurniawan; Sucherly; Surachman

    2015-01-01

    Complaint handling influences brand image which will influence customer loyalty in the future. This research is aimed to find out how the complaint handling is capable to influence against the brand image in building the customer loyalty of Indomaret Minimarket with the study case of Indomaret Minimarket. This research also aims to find out how the complaint handling is conducted by Indomaret Minimarket the brand image of service on Indomaret Minimarket as well as the customer loyalty of Ind...

  10. Iris autofluorescence in Fuchs' heterochromic uveitis.

    Science.gov (United States)

    Liu, Qian; Jia, Yading; Zhang, Suhua; Xie, Juan; Chang, Xin; Hou, Jia; Li, Gaiyun; Koch, Douglas D; Wang, Li

    2016-10-01

    To explore the characteristic autofluorescence patterns of iris depigmentation in eyes diagnosed with Fuchs' heterochromic uveitis (FHU). Near-infrared autofluorescence images and colour images of iris were taken in 21 eyes of 21 patients with FHU, 30 eyes of 15 normal subjects, 30 eyes of 15 normal age-related iris atrophy and 33 eyes of 20 patients with uveitis other than FHU. The confocal scanning laser ophthalmoscope (Heidelberg Retina Angiograph 2, HRA2) was used for melanin-related autofluorescence imaging. The indocyanine green angiography mode of HRA2 was applied for near-infrared laser imaging, and the wavelength of the excitation laser was 795 nm. Iris colour images were also taken with the slit lamp. In normal iris, moderately intense autofluorescence was noted for the pigment ruff at the pupillary border, the crests in the pupillary zone and the collarette; and there was mild autofluorescence in the ciliary zone. In eyes with age-related iris atrophy and uveitis, much less autofluorescence was seen than the healthy normal irides. In eyes with FHU, there was moderate but discontinuous autofluorescence in the pigment ruff, a petaloid pattern of autofluorescence in the pupillary zone, moderate autofluorescence in the collarette and reticular pattern of autofluorescence in the ciliary zone. Characteristic autofluorescence patterns appeared in eyes diagnosed with FHU. Near-infrared autofluorescence is a promising objective technique to document the iris changes in FHU. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. A novel iris patterns matching algorithm of weighted polar frequency correlation

    Science.gov (United States)

    Zhao, Weijie; Jiang, Linhua

    2014-11-01

    Iris recognition is recognized as one of the most accurate techniques for biometric authentication. In this paper, we present a novel correlation method - Weighted Polar Frequency Correlation(WPFC) - to match and evaluate two iris images, actually it can also be used for evaluating the similarity of any two images. The WPFC method is a novel matching and evaluating method for iris image matching, which is complete different from the conventional methods. For instance, the classical John Daugman's method of iris recognition uses 2D Gabor wavelets to extract features of iris image into a compact bit stream, and then matching two bit streams with hamming distance. Our new method is based on the correlation in the polar coordinate system in frequency domain with regulated weights. The new method is motivated by the observation that the pattern of iris that contains far more information for recognition is fine structure at high frequency other than the gross shapes of iris images. Therefore, we transform iris images into frequency domain and set different weights to frequencies. Then calculate the correlation of two iris images in frequency domain. We evaluate the iris images by summing the discrete correlation values with regulated weights, comparing the value with preset threshold to tell whether these two iris images are captured from the same person or not. Experiments are carried out on both CASIA database and self-obtained images. The results show that our method is functional and reliable. Our method provides a new prospect for iris recognition system.

  12. Mapping of land cover in Northern California with simulated HyspIRI images

    Science.gov (United States)

    Clark, M. L.; Kilham, N. E.

    2014-12-01

    Land-cover maps are important science products needed for natural resource and ecosystem service management, biodiversity conservation planning, and assessing human-induced and natural drivers of land change. Most land-cover maps at regional to global scales are produced with remote sensing techniques applied to multispectral satellite imagery with 30-500 m pixel sizes (e.g., Landsat, MODIS). Hyperspectral, or imaging spectrometer, imagery measuring the visible to shortwave infrared regions (i.e., full range) of the spectrum have shown improved capacity to map plant species and coarser land-cover associations, yet techniques have not been widely tested at regional and greater spatial scales. The Hyperspectral Infrared Imager (HyspIRI) mission is a full-range hyperspectral and thermal satellite being considered for development by NASA (hyspiri.jpl.nasa.gov). A hyperspectral satellite, such as HyspIRI, will provide detailed spectral and temporal information at global scales that could greatly improve our ability to map land cover with greater class detail and spatial and temporal accuracy than possible with conventional multispectral satellites. The broad goal of our research is to assess multi-temporal, HyspIRI-like satellite imagery for improved land cover mapping across a range of environmental and anthropogenic gradients in California. In this study, we mapped FAO Land Cover Classification System (LCCS) classes over 30,000 km2 in Northern California using multi-temporal HyspIRI imagery simulated from the AVIRIS airborne sensor. The Random Forests classification was applied to predictor variables derived from the multi-temporal hyperspectral data and accuracies were compared to that from Landsat 8 OLI. Results indicate increased mapping accuracy using HyspIRI multi-temporal imagery, particularly in discriminating different forest life-form types, such as mixed conifer and broadleaf forests and open- and closed-canopy forests.

  13. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor

    Science.gov (United States)

    Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung

    2018-01-01

    Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies. PMID:29695113

  14. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor

    Directory of Open Access Journals (Sweden)

    Dat Tien Nguyen

    2018-04-01

    Full Text Available Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD method for an iris recognition system (iPAD using a near infrared light (NIR camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED. Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM. Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies.

  15. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor.

    Science.gov (United States)

    Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung

    2018-04-24

    Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies.

  16. Deep Learning-Based Iris Segmentation for Iris Recognition in Visible Light Environment

    Directory of Open Access Journals (Sweden)

    Muhammad Arsalan

    2017-11-01

    Full Text Available Existing iris recognition systems are heavily dependent on specific conditions, such as the distance of image acquisition and the stop-and-stare environment, which require significant user cooperation. In environments where user cooperation is not guaranteed, prevailing segmentation schemes of the iris region are confronted with many problems, such as heavy occlusion of eyelashes, invalid off-axis rotations, motion blurs, and non-regular reflections in the eye area. In addition, iris recognition based on visible light environment has been investigated to avoid the use of additional near-infrared (NIR light camera and NIR illuminator, which increased the difficulty of segmenting the iris region accurately owing to the environmental noise of visible light. To address these issues; this study proposes a two-stage iris segmentation scheme based on convolutional neural network (CNN; which is capable of accurate iris segmentation in severely noisy environments of iris recognition by visible light camera sensor. In the experiment; the noisy iris challenge evaluation part-II (NICE-II training database (selected from the UBIRIS.v2 database and mobile iris challenge evaluation (MICHE dataset were used. Experimental results showed that our method outperformed the existing segmentation methods.

  17. Embedded Design Research of Iris Information Acquisition System

    Directory of Open Access Journals (Sweden)

    Huiyan Xu

    2014-09-01

    Full Text Available In view of the limitation of traditional identification, it is easy to lose and copy keys, cards or ID cards, and it is easy to forget the password, so we designed an embedded application system based on the iris identification technology, which can realize the functions of gathering, inputting, and registering the iris information and identification. The hardware circuit was designed by using advanced RISC machines (ARM embedded microprocessor as the core. The iris sensor was used to gather the iris information, and the development of software was accomplished with the embedded OS Windows CE. The system can be used on the company entrance guard system, customs security of airport and criminal identification.

  18. Iterative Redeployment of Illumination and Sensing (IRIS): Application to STW-SAR Imaging

    National Research Council Canada - National Science Library

    Marble, Jay; Raich, Raviv; Hero, Alfred O

    2006-01-01

    .... The IRIS algorithm has the following features: (1) use of a sparse Bayesian image model that captures the free-space dominated propagation characteristics of interiors of man-made structures such as caves and residences; (2...

  19. Toward noncooperative iris recognition: a classification approach using multiple signatures.

    Science.gov (United States)

    Proença, Hugo; Alexandre, Luís A

    2007-04-01

    This paper focuses on noncooperative iris recognition, i.e., the capture of iris images at large distances, under less controlled lighting conditions, and without active participation of the subjects. This increases the probability of capturing very heterogeneous images (regarding focus, contrast, or brightness) and with several noise factors (iris obstructions and reflections). Current iris recognition systems are unable to deal with noisy data and substantially increase their error rates, especially the false rejections, in these conditions. We propose an iris classification method that divides the segmented and normalized iris image into six regions, makes an independent feature extraction and comparison for each region, and combines each of the dissimilarity values through a classification rule. Experiments show a substantial decrease, higher than 40 percent, of the false rejection rates in the recognition of noisy iris images.

  20. Diagnostic potential of iris cross-sectional imaging in albinism using optical coherence tomography.

    Science.gov (United States)

    Sheth, Viral; Gottlob, Irene; Mohammad, Sarim; McLean, Rebecca J; Maconachie, Gail D E; Kumar, Anil; Degg, Christopher; Proudlock, Frank A

    2013-10-01

    To characterize in vivo anatomic abnormalities of the iris in albinism compared with healthy controls using anterior segment optical coherence tomography (AS-OCT) and to explore the diagnostic potential of this technique for albinism. We also investigated the relationship between iris abnormalities and other phenotypical features of albinism. Prospective cross-sectional study. A total of 55 individuals with albinism and 45 healthy controls. We acquired 4.37×4.37-mm volumetric scans (743 A-scans, 50 B-scans) of the nasal and temporal iris in both eyes using AS-OCT (3-μm axial resolution). Iris layers were segmented and thicknesses were measured using ImageJ software. Iris transillumination grading was graded using Summers and colleagues' classification. Retinal OCT, eye movement recordings, best-corrected visual acuity (BCVA), visual evoked potential (VEP), and grading of skin and hair pigmentation were used to quantify other phenotypical features associated with albinism. Iris AS-OCT measurements included (1) total iris thickness, (2) stroma/anterior border (SAB) layer thickness, and (3) posterior epithelial layer (PEL) thickness. Correlation with other phenotypical measurements, including (1) iris transillumination grading, (2) retinal layer measurements at the fovea, (3) nystagmus intensity, (4) BCVA, (5) VEP asymmetry, (6) skin pigmentation, and (7) hair pigmentation (of head hair, lashes, and brows). The mean iris thickness was 10.7% thicker in controls (379.3 ± 44.0 μm) compared with the albinism group (342.5 ± 52.6 μm; P>0.001), SAB layers were 5.8% thicker in controls (315.1 ± 43.8 μm) compared with the albinism group (297.7 ± 50.0 μm; P=0.044), and PEL was 44.0% thicker in controls (64.1 ± 11.7 μm) compared with the albinism group (44.5 ± 13.9 μm; Palbinism. Phenotypic features of albinism, such as skin and hair pigmentation, BCVA, and nystagmus intensity, were significantly correlated to AS-OCT iris thickness measurements. We have

  1. Iris recognition based on robust principal component analysis

    Science.gov (United States)

    Karn, Pradeep; He, Xiao Hai; Yang, Shuai; Wu, Xiao Hong

    2014-11-01

    Iris images acquired under different conditions often suffer from blur, occlusion due to eyelids and eyelashes, specular reflection, and other artifacts. Existing iris recognition systems do not perform well on these types of images. To overcome these problems, we propose an iris recognition method based on robust principal component analysis. The proposed method decomposes all training images into a low-rank matrix and a sparse error matrix, where the low-rank matrix is used for feature extraction. The sparsity concentration index approach is then applied to validate the recognition result. Experimental results using CASIA V4 and IIT Delhi V1iris image databases showed that the proposed method achieved competitive performances in both recognition accuracy and computational efficiency.

  2. Anterior Segment Optical Coherence Tomography Angiography for Identification of Iris Vasculature and Staging of Iris Neovascularization: A Pilot Study.

    Science.gov (United States)

    Roberts, Philipp K; Goldstein, Debra A; Fawzi, Amani A

    2017-08-01

    Purpose/Aim of the study: To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the "eyes at risk" group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI.

  3. Cataract influence on iris recognition performance

    Science.gov (United States)

    Trokielewicz, Mateusz; Czajka, Adam; Maciejewicz, Piotr

    2014-11-01

    This paper presents the experimental study revealing weaker performance of the automatic iris recognition methods for cataract-affected eyes when compared to healthy eyes. There is little research on the topic, mostly incorporating scarce databases that are often deficient in images representing more than one illness. We built our own database, acquiring 1288 eye images of 37 patients of the Medical University of Warsaw. Those images represent several common ocular diseases, such as cataract, along with less ordinary conditions, such as iris pattern alterations derived from illness or eye trauma. Images were captured in near-infrared light (used in biometrics) and for selected cases also in visible light (used in ophthalmological diagnosis). Since cataract is a disorder that is most populated by samples in the database, in this paper we focus solely on this illness. To assess the extent of the performance deterioration we use three iris recognition methodologies (commercial and academic solutions) to calculate genuine match scores for healthy eyes and those influenced by cataract. Results show a significant degradation in iris recognition reliability manifesting by worsening the genuine scores in all three matchers used in this study (12% of genuine score increase for an academic matcher, up to 175% of genuine score increase obtained for an example commercial matcher). This increase in genuine scores affected the final false non-match rate in two matchers. To our best knowledge this is the only study of such kind that employs more than one iris matcher, and analyzes the iris image segmentation as a potential source of decreased reliability

  4. Feature Set Fusion for Spoof Iris Detection

    Directory of Open Access Journals (Sweden)

    P. V. L. Suvarchala

    2018-04-01

    Full Text Available Iris recognition is considered as one of the most promising noninvasive biometric systems providing automated human identification. Numerous programs, like unique ID program in India - Aadhar, include iris biometric to provide distinctive identity identification to citizens. The active area is usually captured under non ideal imaging conditions. It usually suffers from poor brightness, low contrast, blur due to camera or subject's relative movement and eyelid eyelash occlusions. Besides the technical challenges, iris recognition started facing sophisticated threats like spoof attacks. Therefore it is vital that the integrity of such large scale iris deployments must be preserved. This paper presents the development of a new spoof resistant approach which exploits the statistical dependencies of both general eye and localized iris regions in textural domain using spatial gray level dependence matrix (SGLDM, gray level run length matrix (GLRLM and contourlets in transform domain. We did experiments on publicly available fake and lens iris image databases. Correct classification rate obtained with ATVS-FIr iris database is 100% while it is 95.63% and 88.83% with IITD spoof iris databases respectively.

  5. The Antecedents of Store Image and Customer Satisfaction

    Directory of Open Access Journals (Sweden)

    Banu Kulter Demirgunes

    2016-01-01

    Full Text Available Definition of store image is argued to be useful if it predicts phenomena such as satisfaction, loyalty, customer retention and other attitudinal and behavioral outcomes. Previous researches show that customers are affected by the store attributes and consider them to assess perceived benefits and attitudes. One of the biggest challenges for companies is to build a positive image. Knowing the alternatives which could be used to form a positive image is an important issue. A positive image which is created in the customer’s mind about store is seen to have a strong and positive influence on satisfaction. A satisfied customer is likely to be loyal to the store. Therefore, image and customer satisfaction gain importance in the stores which aim to survive. This study focuses on store image, customer satisfaction and the relationship between them. The study primarily explains these two concepts, and then provides a literature review on the researches related with them. The study presents researches in which store image and customer satisfaction are separately discussed, thus it also shows other variables which can be influential on these concepts. Implications for both store image theory and practices are discussed. The literature review reveals that store image plays an important role in customer satisfaction.  Since most of the studies in literature are based on retail industry, in this study ‘store’ concept mostly refers to ‘retail store’.

  6. DCT-based iris recognition.

    Science.gov (United States)

    Monro, Donald M; Rakshit, Soumyadip; Zhang, Dexin

    2007-04-01

    This paper presents a novel iris coding method based on differences of discrete cosine transform (DCT) coefficients of overlapped angular patches from normalized iris images. The feature extraction capabilities of the DCT are optimized on the two largest publicly available iris image data sets, 2,156 images of 308 eyes from the CASIA database and 2,955 images of 150 eyes from the Bath database. On this data, we achieve 100 percent Correct Recognition Rate (CRR) and perfect Receiver-Operating Characteristic (ROC) Curves with no registered false accepts or rejects. Individual feature bit and patch position parameters are optimized for matching through a product-of-sum approach to Hamming distance calculation. For verification, a variable threshold is applied to the distance metric and the False Acceptance Rate (FAR) and False Rejection Rate (FRR) are recorded. A new worst-case metric is proposed for predicting practical system performance in the absence of matching failures, and the worst case theoretical Equal Error Rate (EER) is predicted to be as low as 2.59 x 10(-4) on the available data sets.

  7. The Antecedents of Store Image and Customer Satisfaction

    Directory of Open Access Journals (Sweden)

    Banu Külter Demirgüneş

    2014-07-01

    Full Text Available Definition ofstore image is argued to be useful if it predicts phenomena such assatisfaction, loyalty, customer retention and other attitudinal and behavioraloutcomes. Previous researches show that customers are affected by the storeattributes and consider them to assess perceived benefits and attitudes. One ofthe biggest challenges for companies is to build a positive image. Knowing thealternatives which could be used to form a positive image is an importantissue.A positive image which iscreated in the customer’s mind about store is seen to have a strong andpositive influence on satisfaction. A satisfied customer is likely to be loyalto the store. Therefore, image and customer satisfaction gain importance in thestores which aim to survive.     This study focuses on store image, customer satisfaction and therelationship between them. The study primarily explains these two concepts, andthen provides a literature review on the researches related with them. The study presents researches in which store image andcustomer satisfaction are separately discussed, thus it also shows othervariables which can be influential on these concepts. Implications for bothstore image theory and practices are discussed. The literature review revealsthat store image plays an important role in customer satisfaction.  Sincemost of the studies in literature are based on retail industry, in this study‘store’ concept mostly refers to ‘retail store’.

  8. Iris unwrapping using the Bresenham circle algorithm for real-time iris recognition

    Science.gov (United States)

    Carothers, Matthew T.; Ngo, Hau T.; Rakvic, Ryan N.; Broussard, Randy P.

    2015-02-01

    An efficient parallel architecture design for the iris unwrapping process in a real-time iris recognition system using the Bresenham Circle Algorithm is presented in this paper. Based on the characteristics of the model parameters this algorithm was chosen over the widely used polar conversion technique as the iris unwrapping model. The architecture design is parallelized to increase the throughput of the system and is suitable for processing an inputted image size of 320 × 240 pixels in real-time using Field Programmable Gate Array (FPGA) technology. Quartus software is used to implement, verify, and analyze the design's performance using the VHSIC Hardware Description Language. The system's predicted processing time is faster than the modern iris unwrapping technique used today∗.

  9. Improving iris recognition performance using segmentation, quality enhancement, match score fusion, and indexing.

    Science.gov (United States)

    Vatsa, Mayank; Singh, Richa; Noore, Afzel

    2008-08-01

    This paper proposes algorithms for iris segmentation, quality enhancement, match score fusion, and indexing to improve both the accuracy and the speed of iris recognition. A curve evolution approach is proposed to effectively segment a nonideal iris image using the modified Mumford-Shah functional. Different enhancement algorithms are concurrently applied on the segmented iris image to produce multiple enhanced versions of the iris image. A support-vector-machine-based learning algorithm selects locally enhanced regions from each globally enhanced image and combines these good-quality regions to create a single high-quality iris image. Two distinct features are extracted from the high-quality iris image. The global textural feature is extracted using the 1-D log polar Gabor transform, and the local topological feature is extracted using Euler numbers. An intelligent fusion algorithm combines the textural and topological matching scores to further improve the iris recognition performance and reduce the false rejection rate, whereas an indexing algorithm enables fast and accurate iris identification. The verification and identification performance of the proposed algorithms is validated and compared with other algorithms using the CASIA Version 3, ICE 2005, and UBIRIS iris databases.

  10. The Image of Financial Institution as Islamic Bank In Mediation Service Quality and Customer Satisfaction on Customer Loyalty in Purwokerto.

    Directory of Open Access Journals (Sweden)

    Chandra Warsito

    2015-10-01

    Full Text Available The paper aims to determine the effect of service quality on customer satisfaction, service quality, customer satisfaction and image on customer loyalty, quality of service to the company’s image, to determine the image of financial institutions in mediating the relationship variable quality of service and customer satisfaction on customer loyalty. The samples used were 110 customers and methods of analysis used is Structural Equation Modeling (SEM test results find no significant effect of service quality on customer satisfaction; quality of service loyalty; customer satisfaction on customer loyalty; quality of service to the image of the company; customer satisfaction with the company’s image; and the image of the company loyalty; Image of financial institutions PT. BPRS BAS can be used as a variable relationship mediation variable service quality and customer satisfaction on customer loyalty.DOI: 10.15408/aiq.v7i2.1699

  11. A new objective criterion for IRIS localization

    International Nuclear Information System (INIS)

    Basit, A.

    2010-01-01

    Iris localization is the most important step in iris recognition systems. For commonly used databases, exact data is not given which describe the true results of localization. To cope with this problem a new objective criterion for iris localization is proposed in this paper based on our visual system. A specific number of points are selected on pupil boundary, iris boundary, upper eyelid and lower eyelid using the original image and then distance from these points to the result of complete iris localization has been calculated. If the determined distance is below a certain threshold then iris localization is considered correct. Experimental results show that proposed criterion is very effective. (author)

  12. Edge detection techniques for iris recognition system

    International Nuclear Information System (INIS)

    Tania, U T; Motakabber, S M A; Ibrahimy, M I

    2013-01-01

    Nowadays security and authentication are the major parts of our daily life. Iris is one of the most reliable organ or part of human body which can be used for identification and authentication purpose. To develop an iris authentication algorithm for personal identification, this paper examines two edge detection techniques for iris recognition system. Between the Sobel and the Canny edge detection techniques, the experimental result shows that the Canny's technique has better ability to detect points in a digital image where image gray level changes even at slow rate

  13. Comparison of anterior segment optical coherence tomography angiography and fluorescein angiography for iris vasculature analysis.

    Science.gov (United States)

    Zett, Claudio; Stina, Deborah M Rosa; Kato, Renata Tiemi; Novais, Eduardo Amorim; Allemann, Norma

    2018-04-01

    The aim of this study is to perform imaging of irises of different colors using spectral domain anterior segment optical coherence tomography angiography (AS-OCTA) and iris fluorescein angiography (IFA) and compare their effectiveness in examining iris vasculature. This is a cross-sectional observational clinical study. Patients with no vascular iris alterations and different pigmentation levels were recruited. Participants were imaged using OCTA adapted with an anterior segment lens and IFA with a confocal scanning laser ophthalmoscope (cSLO) adapted with an anterior segment lens. AS-OCTA and IFA images were then compared. Two blinded readers classified iris pigmentation and compared the percentage of visible vessels between OCTA and IFA images. Twenty eyes of 10 patients with different degrees of iris pigmentation were imaged using AS-OCTA and IFA. Significantly more visible iris vessels were observed using OCTA than using FA (W = 5.22; p Iris pigmentation was negatively correlated to the percentage of visible vessels in both imaging methods (OCTA, rho = - 0.73, p iris vasculature. In both AS-OCTA and IFA, iris pigmentation caused vasculature imaging blockage, but AS-OCTA provided more detailed iris vasculature images than IFA. Additional studies including different iris pathologies are needed to determine the most optimal scanning parameters in OCTA of the anterior segment.

  14. Efficient iris recognition by characterizing key local variations.

    Science.gov (United States)

    Ma, Li; Tan, Tieniu; Wang, Yunhong; Zhang, Dexin

    2004-06-01

    Unlike other biometrics such as fingerprints and face, the distinct aspect of iris comes from randomly distributed features. This leads to its high reliability for personal identification, and at the same time, the difficulty in effectively representing such details in an image. This paper describes an efficient algorithm for iris recognition by characterizing key local variations. The basic idea is that local sharp variation points, denoting the appearing or vanishing of an important image structure, are utilized to represent the characteristics of the iris. The whole procedure of feature extraction includes two steps: 1) a set of one-dimensional intensity signals is constructed to effectively characterize the most important information of the original two-dimensional image; 2) using a particular class of wavelets, a position sequence of local sharp variation points in such signals is recorded as features. We also present a fast matching scheme based on exclusive OR operation to compute the similarity between a pair of position sequences. Experimental results on 2255 iris images show that the performance of the proposed method is encouraging and comparable to the best iris recognition algorithm found in the current literature.

  15. IRIS Mission Operations Director's Colloquium

    Science.gov (United States)

    Carvalho, Robert; Mazmanian, Edward A.

    2014-01-01

    Pursuing the Mysteries of the Sun: The Interface Region Imaging Spectrograph (IRIS) Mission. Flight controllers from the IRIS mission will present their individual experiences on IRIS from development through the first year of flight. This will begin with a discussion of the unique nature of IRISs mission and science, and how it fits into NASA's fleet of solar observatories. Next will be a discussion of the critical roles Ames contributed in the mission including spacecraft and flight software development, ground system development, and training for launch. This will be followed by experiences from launch, early operations, ongoing operations, and unusual operations experiences. The presentation will close with IRIS science imagery and questions.

  16. Optimal wavelength band clustering for multispectral iris recognition.

    Science.gov (United States)

    Gong, Yazhuo; Zhang, David; Shi, Pengfei; Yan, Jingqi

    2012-07-01

    This work explores the possibility of clustering spectral wavelengths based on the maximum dissimilarity of iris textures. The eventual goal is to determine how many bands of spectral wavelengths will be enough for iris multispectral fusion and to find these bands that will provide higher performance of iris multispectral recognition. A multispectral acquisition system was first designed for imaging the iris at narrow spectral bands in the range of 420 to 940 nm. Next, a set of 60 human iris images that correspond to the right and left eyes of 30 different subjects were acquired for an analysis. Finally, we determined that 3 clusters were enough to represent the 10 feature bands of spectral wavelengths using the agglomerative clustering based on two-dimensional principal component analysis. The experimental results suggest (1) the number, center, and composition of clusters of spectral wavelengths and (2) the higher performance of iris multispectral recognition based on a three wavelengths-bands fusion.

  17. A novel iris localization algorithm using correlation filtering

    Science.gov (United States)

    Pohit, Mausumi; Sharma, Jitu

    2015-06-01

    Fast and efficient segmentation of iris from the eye images is a primary requirement for robust database independent iris recognition. In this paper we have presented a new algorithm for computing the inner and outer boundaries of the iris and locating the pupil centre. Pupil-iris boundary computation is based on correlation filtering approach, whereas iris-sclera boundary is determined through one dimensional intensity mapping. The proposed approach is computationally less extensive when compared with the existing algorithms like Hough transform.

  18. Iris Recognition for Partially Occluded Images: Methodology and Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    Poursaberi A

    2007-01-01

    Full Text Available Accurate iris detection is a crucial part of an iris recognition system. One of the main issues in iris segmentation is coping with occlusion that happens due to eyelids and eyelashes. In the literature, some various methods have been suggested to solve the occlusion problem. In this paper, two different segmentations of iris are presented. In the first algorithm, a circle is located around the pupil with an appropriate diameter. The iris area encircled by the circular boundary is used for recognition purposes then. In the second method, again a circle is located around the pupil with a larger diameter. This time, however, only the lower part of the encircled iris area is utilized for individual recognition. Wavelet-based texture features are used in the process. Hamming and harmonic mean distance classifiers are exploited as a mixed classifier in suggested algorithm. It is observed that relying on a smaller but more reliable part of the iris, though reducing the net amount of information, improves the overall performance. Experimental results on CASIA database show that our method has a promising performance with an accuracy of 99.31%. The sensitivity of the proposed method is analyzed versus contrast, illumination, and noise as well, where lower sensitivity to all factors is observed when the lower half of the iris is used for recognition.

  19. New methods in iris recognition.

    Science.gov (United States)

    Daugman, John

    2007-10-01

    This paper presents the following four advances in iris recognition: 1) more disciplined methods for detecting and faithfully modeling the iris inner and outer boundaries with active contours, leading to more flexible embedded coordinate systems; 2) Fourier-based methods for solving problems in iris trigonometry and projective geometry, allowing off-axis gaze to be handled by detecting it and "rotating" the eye into orthographic perspective; 3) statistical inference methods for detecting and excluding eyelashes; and 4) exploration of score normalizations, depending on the amount of iris data that is available in images and the required scale of database search. Statistical results are presented based on 200 billion iris cross-comparisons that were generated from 632500 irises in the United Arab Emirates database to analyze the normalization issues raised in different regions of receiver operating characteristic curves.

  20. The impact of brand image on customer experience – Company X

    OpenAIRE

    Siitonen, Hannes

    2017-01-01

    The aim of this thesis was to find out what kind of relationship there is between brand image and customer experience, and how the brand image affects to customer experience. The aim was also to define the company’s brand image and customer experience among the target groups, and what factors do affect to them. In addition, this thesis aimed to produce valuable information for the company about their brand image, customer experience, customer behaviour and customer satisfaction, followed by i...

  1. Iris Location Algorithm Based on the CANNY Operator and Gradient Hough Transform

    Science.gov (United States)

    Zhong, L. H.; Meng, K.; Wang, Y.; Dai, Z. Q.; Li, S.

    2017-12-01

    In the iris recognition system, the accuracy of the localization of the inner and outer edges of the iris directly affects the performance of the recognition system, so iris localization has important research meaning. Our iris data contain eyelid, eyelashes, light spot and other noise, even the gray transformation of the images is not obvious, so the general methods of iris location are unable to realize the iris location. The method of the iris location based on Canny operator and gradient Hough transform is proposed. Firstly, the images are pre-processed; then, calculating the gradient information of images, the inner and outer edges of iris are coarse positioned using Canny operator; finally, according to the gradient Hough transform to realize precise localization of the inner and outer edge of iris. The experimental results show that our algorithm can achieve the localization of the inner and outer edges of the iris well, and the algorithm has strong anti-interference ability, can greatly reduce the location time and has higher accuracy and stability.

  2. An automatic iris occlusion estimation method based on high-dimensional density estimation.

    Science.gov (United States)

    Li, Yung-Hui; Savvides, Marios

    2013-04-01

    Iris masks play an important role in iris recognition. They indicate which part of the iris texture map is useful and which part is occluded or contaminated by noisy image artifacts such as eyelashes, eyelids, eyeglasses frames, and specular reflections. The accuracy of the iris mask is extremely important. The performance of the iris recognition system will decrease dramatically when the iris mask is inaccurate, even when the best recognition algorithm is used. Traditionally, people used the rule-based algorithms to estimate iris masks from iris images. However, the accuracy of the iris masks generated this way is questionable. In this work, we propose to use Figueiredo and Jain's Gaussian Mixture Models (FJ-GMMs) to model the underlying probabilistic distributions of both valid and invalid regions on iris images. We also explored possible features and found that Gabor Filter Bank (GFB) provides the most discriminative information for our goal. Finally, we applied Simulated Annealing (SA) technique to optimize the parameters of GFB in order to achieve the best recognition rate. Experimental results show that the masks generated by the proposed algorithm increase the iris recognition rate on both ICE2 and UBIRIS dataset, verifying the effectiveness and importance of our proposed method for iris occlusion estimation.

  3. The concave iris in pigment dispersion syndrome.

    Science.gov (United States)

    Liu, Lance; Ong, Ee Lin; Crowston, Jonathan

    2011-01-01

    To visualize the changes of the iris contour in patients with pigment dispersion syndrome after blinking, accommodation, and pharmacologic miosis using anterior segment optical coherence tomography. Observational case series. A total of 33 eyes of 20 patients with pigment dispersion syndrome. Each eye was imaged along the horizontal 0- to 180-degree meridian using the Visante Anterior Segment Imaging System (Carl Zeiss Meditec, Dublin, CA). Scans were performed at baseline and after focusing on an internal fixation target for 5 minutes, forced blinking, accommodation, and pharmacologic miosis with pilocarpine 2%. Quantitative analysis of the changes in the iris configuration. After 5 minutes of continual fixation, the iris became planar with the mean ± standard deviation curvature decreasing from 214 ± 74 μm to 67 ± 76 μm (P pigment dispersion syndrome after forced blinking, but the iris concavity recovered to 227 ± 113 μm (P = 0.34) and 238 ± 119 μm (P = 0.19) with the -3.0 and -6.0 diopter lenses, respectively. Pilocarpine-induced miosis caused the iris to assume a planar configuration in all subjects. This study shows that the iris in pigment dispersion syndrome assumes a planar configuration when fixating and that the concavity of the iris surface is not restored by blinking. Accommodation restored the iris concavity, suggesting that the posterior curvature of the iris in pigment dispersion syndrome is induced and probably maintained, at least in part, by accommodation. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. INFLUENCE OF CUSTOMER VALUES AND SELF-IMAGE CONGRUITY ON CUSTOMER BEHAVIOR-BASED CRM PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Mandy Loh

    2015-10-01

    Full Text Available The purpose of this study is to investigate the influence of the key dimensions of customer value (functional value, emotional value, social value, and perceived sacrifice and self-image congruity on customer-behavior based CRM performance. The study also attempts to investigate on the effect of key dimensions of customer value and self-image congruity on customer satisfaction and brand loyalty. The research model for this study was adopts an integrated framework from a previous study, and adds new element into it. This study has chosen to examine the framework in the retail industry, specifically hypermarket in Malaysia, where the adoption of CRM tools is increasing incrementally. The study target on the Generation Y who believed will be the future driver of retail industry. The findings show that perceived sacrifice appears to be a critical customer perceived value in influencing the customer behavior-based CRM performance and customer satisfaction. This study show that brand loyalty would directly influence the customer behavior-based CRM performance. Perceived sacrifice and brand loyalty should be focused when trying to improve the performance of CRM.

  5. Iris analysis for biometric recognition systems

    CERN Document Server

    Bodade, Rajesh M

    2014-01-01

    The book presents three most significant areas in Biometrics and Pattern Recognition. A step-by-step approach for design and implementation of Dual Tree Complex Wavelet Transform (DTCWT) plus Rotated Complex Wavelet Filters (RCWF) is discussed in detail. In addition to the above, the book provides detailed analysis of iris images and two methods of iris segmentation. It also discusses simplified study of some subspace-based methods and distance measures for iris recognition backed by empirical studies and statistical success verifications.

  6. Efficient Iris Localization via Optimization Model

    Directory of Open Access Journals (Sweden)

    Qi Wang

    2017-01-01

    Full Text Available Iris localization is one of the most important processes in iris recognition. Because of different kinds of noises in iris image, the localization result may be wrong. Besides this, localization process is time-consuming. To solve these problems, this paper develops an efficient iris localization algorithm via optimization model. Firstly, the localization problem is modeled by an optimization model. Then SIFT feature is selected to represent the characteristic information of iris outer boundary and eyelid for localization. And SDM (Supervised Descent Method algorithm is employed to solve the final points of outer boundary and eyelids. Finally, IRLS (Iterative Reweighted Least-Square is used to obtain the parameters of outer boundary and upper and lower eyelids. Experimental result indicates that the proposed algorithm is efficient and effective.

  7. Enhancement of Iris Recognition System Based on Phase Only Correlation

    Directory of Open Access Journals (Sweden)

    Nuriza Pramita

    2011-08-01

    Full Text Available Iris recognition system is one of biometric based recognition/identification systems. Numerous techniques have been implemented to achieve a good recognition rate, including the ones based on Phase Only Correlation (POC. Significant and higher correlation peaks suggest that the system recognizes iris images of the same subject (person, while lower and unsignificant peaks correspond to recognition of those of difference subjects. Current POC methods have not investigated minimum iris point that can be used to achieve higher correlation peaks. This paper proposed a method that used only one-fourth of full normalized iris size to achieve higher (or at least the same recognition rate. Simulation on CASIA version 1.0 iris image database showed that averaged recognition rate of the proposed method achieved 67%, higher than that of using one-half (56% and full (53% iris point. Furthermore, all (100% POC peak values of the proposed method was higher than that of the method with full iris points.

  8. A Study on Iris Localization and Recognition on Mobile Phones

    Directory of Open Access Journals (Sweden)

    Dae Sik Jeong

    2007-11-01

    Full Text Available A new iris recognition method for mobile phones based on corneal specular reflections (SRs is discussed. We present the following three novelties over previous research. First, in case of user with glasses, many noncorneal SRs may happen on the surface of glasses and it is very difficult to detect genuine SR on the cornea. To overcome such problems, we propose a successive on/off dual illuminator scheme to detect genuine SRs on the corneas of users with glasses. Second, to detect SRs robustly, we estimated the size, shape, and brightness of the SRs based on eye, camera, and illuminator models. Third, the detected eye (iris region was verified again using the AdaBoost eye detector. Experimental results with 400 face images captured from 100 persons with a mobile phone camera showed that the rate of correct iris detection was 99.5% (for images without glasses and 98.9% (for images with glasses or contact lenses. The consequent accuracy of iris authentication was 0.05% of the EER (equal error rate based on detected iris images.

  9. Correlation of iris biometrics and DNA

    DEFF Research Database (Denmark)

    Harder, Stine; Clemmensen, Line Katrine Harder; Dahl, Anders Bjorholm

    2013-01-01

    The presented work concerns prediction of complex human phenotypes from genotypes. We were interested in correlating iris color and texture with DNA. Our data consist of 212 eye images along with DNA: 32 single-nucleotide polymorphisms (SNPs). We used two types of biometrics to describe the eye...... images: One for iris color and one for iris texture. Both biometrics were high dimensional and a sparse principle component analysis (SPCA) reduced the dimensions and resulted in a representation of data with good interpretability. The correlations between the sparse principal components (SPCs......) and the 32 SNPs were found using a canonical correlation analysis (CCA). The result was a single significant canonical correlation (CC) for both biometrics. Each CC comprised two correlated canonical variables, consisting of a linear combination of SPCs and a linear combination of SNPs, respectively...

  10. Changes of the eye optics after iris constriction

    Directory of Open Access Journals (Sweden)

    Robert Montés-Micó

    2010-10-01

    Conclusion: Iris constriction slightly modifies the optics of the eye. The small hyperopic shift of the best image plane after iris constriction may be explained by a change in the lens shape and/or position.

  11. Feature Vector Construction Method for IRIS Recognition

    Science.gov (United States)

    Odinokikh, G.; Fartukov, A.; Korobkin, M.; Yoo, J.

    2017-05-01

    One of the basic stages of iris recognition pipeline is iris feature vector construction procedure. The procedure represents the extraction of iris texture information relevant to its subsequent comparison. Thorough investigation of feature vectors obtained from iris showed that not all the vector elements are equally relevant. There are two characteristics which determine the vector element utility: fragility and discriminability. Conventional iris feature extraction methods consider the concept of fragility as the feature vector instability without respect to the nature of such instability appearance. This work separates sources of the instability into natural and encodinginduced which helps deeply investigate each source of instability independently. According to the separation concept, a novel approach of iris feature vector construction is proposed. The approach consists of two steps: iris feature extraction using Gabor filtering with optimal parameters and quantization with separated preliminary optimized fragility thresholds. The proposed method has been tested on two different datasets of iris images captured under changing environmental conditions. The testing results show that the proposed method surpasses all the methods considered as a prior art by recognition accuracy on both datasets.

  12. The Relationship of Corporate and Brand Images, Quality of Services, Customer Satisfaction with Customers Loyalty in Banking Industry

    Directory of Open Access Journals (Sweden)

    *L. Borhani

    2014-12-01

    Full Text Available This study aimed at investigating the relationship of corporate and brand images, quality of services, and customer satisfaction with customer’s loyalty in banking industry in Meybod. Data was collected through questionnaires from 180 customers of six banks. Measurement tools were Loyalty Scale, Corporate Image Scale, Brand Image Scale, Customer Satisfaction Scale and Service Quality Scale. The results of correlation and regression analysis indicated that positive relationships exist between loyalty and the following variables: corporate and brand images, quality of services and customer satisfaction (p≤0.008. Also satisfaction was the most powerful predictor of loyalty and addition of corporate image and service quality significantly increased prediction of loyalty (p<0.01. Brand image and age could not predict loyalty and were not entered into analysis.

  13. Dynamic Features for Iris Recognition.

    Science.gov (United States)

    da Costa, R M; Gonzaga, A

    2012-08-01

    The human eye is sensitive to visible light. Increasing illumination on the eye causes the pupil of the eye to contract, while decreasing illumination causes the pupil to dilate. Visible light causes specular reflections inside the iris ring. On the other hand, the human retina is less sensitive to near infra-red (NIR) radiation in the wavelength range from 800 nm to 1400 nm, but iris detail can still be imaged with NIR illumination. In order to measure the dynamic movement of the human pupil and iris while keeping the light-induced reflexes from affecting the quality of the digitalized image, this paper describes a device based on the consensual reflex. This biological phenomenon contracts and dilates the two pupils synchronously when illuminating one of the eyes by visible light. In this paper, we propose to capture images of the pupil of one eye using NIR illumination while illuminating the other eye using a visible-light pulse. This new approach extracts iris features called "dynamic features (DFs)." This innovative methodology proposes the extraction of information about the way the human eye reacts to light, and to use such information for biometric recognition purposes. The results demonstrate that these features are discriminating features, and, even using the Euclidean distance measure, an average accuracy of recognition of 99.1% was obtained. The proposed methodology has the potential to be "fraud-proof," because these DFs can only be extracted from living irises.

  14. IS (Iris Security)

    OpenAIRE

    Iovane, G.; Tortoriello, F. S.

    2003-01-01

    In the paper will be presented a safety system based on iridology. The results suggest a new scenario where the security problem in supervised and unsupervised areas can be treat with the present system and the iris image recognition.

  15. IRIS COLOUR CLASSIFICATION SCALES--THEN AND NOW.

    Science.gov (United States)

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual's eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale.

  16. Texture Feature Extraction and Classification for Iris Diagnosis

    Science.gov (United States)

    Ma, Lin; Li, Naimin

    Appling computer aided techniques in iris image processing, and combining occidental iridology with the traditional Chinese medicine is a challenging research area in digital image processing and artificial intelligence. This paper proposes an iridology model that consists the iris image pre-processing, texture feature analysis and disease classification. To the pre-processing, a 2-step iris localization approach is proposed; a 2-D Gabor filter based texture analysis and a texture fractal dimension estimation method are proposed for pathological feature extraction; and at last support vector machines are constructed to recognize 2 typical diseases such as the alimentary canal disease and the nerve system disease. Experimental results show that the proposed iridology diagnosis model is quite effective and promising for medical diagnosis and health surveillance for both hospital and public use.

  17. Gabor Weber Local Descriptor for Bovine Iris Recognition

    OpenAIRE

    Sun, Shengnan; Zhao, Lindu; Yang, Shicai

    2013-01-01

    Iris recognition is a robust biometric technology. This paper proposes a novel local descriptor for bovine iris recognition, named Gabor Weber local descriptor (GWLD). We first compute the Gabor magnitude maps for the input bovine iris image, and then calculate the differential excitation and orientation for each pixel over each Gabor magnitude map. After that, we use these differential excitations and orientations to construct the GWLD histogram representation. Finally, histogram intersectio...

  18. THE EFFECT OF BANK IMAGE AND TRUST ON LOYALITY MEDIATED BY CUSTOMER SATISFACTION

    Directory of Open Access Journals (Sweden)

    Sumadi Sumadi

    2015-09-01

    Full Text Available The purpose of this study is to analyze the effect of the bank’s image and trust on customer satisfaction, as well as the effect of the image of the bank, trust, and satisfaction on customer loyalty. The study used sample of 100 people who were taken by purposive sampling technique. This research utilized multiple linear regression analysis and path analysis. Based on the hypothesis test, the results show that the image of the bank was significantly has positive effect on customer satisfaction, but trust has no significant effect on customer satisfaction. In addition, the bank’s image has no significant effect on customer loyalty. Moreover, trust and customer satisfaction significantly have positive effect on customer loyalty. Mediation test shows that customer satisfaction mediates the effect of the bank’s image on customer loyalty and customer satisfaction does not mediate trust on customer loyalty. Info

  19. The effects of service quality and corporate rebranding on brand image, customer satisfaction, brand equity and customer loyalty: study in advertising company at tvOne

    OpenAIRE

    CHANIAGO ASPIZAIN

    2016-01-01

    The purpose of this study was to analyze the effects of service quality on brand image, service quality on customer satisfaction, service quality on brand equity, service quality on customer loyalty, corporate rebranding on brand image, corporate rebranding on customer satisfaction, corporate rebranding on brand equity, brand image on customer satisfaction, corporate rebranding on customer loyalty, brand image on brand equity, brand image on customer loyalty, customer satisfaction on customer...

  20. The effect of corporate image on the formation of customer attraction

    Directory of Open Access Journals (Sweden)

    Reza Koohjani Gouji

    2016-10-01

    Full Text Available This paper examines the relationship of corporate image with customer attraction in Irancell Telecommunications Services Company in city of Ahvaz, Iran. The study uses a sample of 384 randomly selected people who use the firm’s services. Measuring tools for corporate image and customer attraction are an 18-item questionnaire of Rampersad (2001 [Rampersad, H. (2001. 75 painful questions about your customer satisfaction. the TQM Magazine, 13(5, 341-347.] and a 14-item questionnaire of Geib (2005 [Geib, M. (2005. Architecture for customer relationship management to attract and retain customers approaches in financial services, IEEE, Proceedings of the 38th Hawaii International Conference on System Sciences.], respectively. Results of regression analysis showed that there was a significant relationship between corporate image and attracting customers in Irancell firm. In addition, dimensions of corporate image including experience, character, competence, quality, differentiation, cost, technology, and culture and cognition increase customer attraction to the company. On the other hand, component of culture has the most effect on attracting customers in this firm.

  1. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients.

    Science.gov (United States)

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-03-01

    To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.

  2. CUSTOMER SATISFACTION IN AN SME: A CUSTOMER PERSPECTIVE IN PERCEIVED VALUE AND LOCAL BRAND IMAGE

    Directory of Open Access Journals (Sweden)

    Yulianti F.

    2017-12-01

    Full Text Available This study is aimed to understand the relationship of perceived quality and brand image on customer satisfaction of Sasirangan Consumer. The study were taken at Banjarmasin, South Kalimantan Province, Indonesia. The object of this study is SME’s Sasirangan (Kain Sasirangan. The object was taken since it has a deep local wisdom and deep meaning for Banjarmasin society (Banua. The subject taken in this research is youngsters at college. This group of subject taken since today’s youngsters has a unique characteristics that also affecting their taste on certain product. The sample was as many as 139 people involved, and executed by using Partial-Least-Square SEM (PLS-SEM. The results of the study shows that either perceived quality or brand image positively increasing the customer satisfaction. Based on the model examination, the perceived value are able to directly affecting the customer satisfaction rather than that affected by brand image. However the indirect effect also indicate that the brand image are also able to mediate the effect of perceived quality on customer satisfaction. The limitation of this study is the object is a single object that may affect the degree of generality against another research.

  3. THE EFFECTS OF SERVICE QUALITY AND CORPORATE REBRANDING ON BRAND IMAGE, CUSTOMER SATISFACTION, BRAND EQUITY AND CUSTOMER LOYALTY: STUDY IN ADVERTISING COMPANY AT TVONE

    Directory of Open Access Journals (Sweden)

    Chaniago A.

    2016-12-01

    Full Text Available The purpose of this study was to analyze the effects of service quality on brand image, service quality on customer satisfaction, service quality on brand equity, service quality on customer loyalty, corporate rebranding on brand image, corporate rebranding on customer satisfaction, corporate rebranding on brand equity, brand image on customer satisfaction, corporate rebranding on customer loyalty, brand image on brand equity, brand image on customer loyalty, customer satisfaction on customer loyalty, brand equity on customer loyalty. The population of this study consisted of loyal 173 corporate advertisers to tvOne - an Indonesian national television company. The sample for this study was set as many as 173, but only 144 respondents who returned the feedback as part of the study. The 144 data were analyzed by using descriptive and inferential analysis of SEM. The research has proven that (1 the service quality significantly affects the brand image; (2 the service quality significantly influence the customer satisfaction; (3 the service quality significantly affects the brand equity; (4 the service quality significantly affects the customer loyalty; (5 the corporate rebranding has significant effects on the brand image; (6 the corporate rebranding has no significant effect on the customer satisfaction; (7 the corporate rebranding has no significant effect on brand equity; (8 the corporate rebranding has no significant effect on the customer loyalty; (9 the brand image has significant effect on the customer satisfaction; (10 the brand image has significant effects on the brand equity; (11 the brand image does not have significant effects on the customer loyalty; (12 significant effects from the customer satisfaction on customer loyalty; and (13 significant effects of the brand equity on the customer loyalty.

  4. Gabor Weber Local Descriptor for Bovine Iris Recognition

    Directory of Open Access Journals (Sweden)

    Shengnan Sun

    2013-01-01

    Full Text Available Iris recognition is a robust biometric technology. This paper proposes a novel local descriptor for bovine iris recognition, named Gabor Weber local descriptor (GWLD. We first compute the Gabor magnitude maps for the input bovine iris image, and then calculate the differential excitation and orientation for each pixel over each Gabor magnitude map. After that, we use these differential excitations and orientations to construct the GWLD histogram representation. Finally, histogram intersection is adopted to measure the similarity between different GWLD histograms. The experimental results on the SEU bovine iris database verify the representation power of our proposed local descriptor.

  5. Point spread function engineering for iris recognition system design.

    Science.gov (United States)

    Ashok, Amit; Neifeld, Mark A

    2010-04-01

    Undersampling in the detector array degrades the performance of iris-recognition imaging systems. We find that an undersampling of 8 x 8 reduces the iris-recognition performance by nearly a factor of 4 (on CASIA iris database), as measured by the false rejection ratio (FRR) metric. We employ optical point spread function (PSF) engineering via a Zernike phase mask in conjunction with multiple subpixel shifted image measurements (frames) to mitigate the effect of undersampling. A task-specific optimization framework is used to engineer the optical PSF and optimize the postprocessing parameters to minimize the FRR. The optimized Zernike phase enhanced lens (ZPEL) imager design with one frame yields an improvement of nearly 33% relative to a thin observation module by bounded optics (TOMBO) imager with one frame. With four frames the optimized ZPEL imager achieves a FRR equal to that of the conventional imager without undersampling. Further, the ZPEL imager design using 16 frames yields a FRR that is actually 15% lower than that obtained with the conventional imager without undersampling.

  6. Novel approaches to improve iris recognition system performance based on local quality evaluation and feature fusion.

    Science.gov (United States)

    Chen, Ying; Liu, Yuanning; Zhu, Xiaodong; Chen, Huiling; He, Fei; Pang, Yutong

    2014-01-01

    For building a new iris template, this paper proposes a strategy to fuse different portions of iris based on machine learning method to evaluate local quality of iris. There are three novelties compared to previous work. Firstly, the normalized segmented iris is divided into multitracks and then each track is estimated individually to analyze the recognition accuracy rate (RAR). Secondly, six local quality evaluation parameters are adopted to analyze texture information of each track. Besides, particle swarm optimization (PSO) is employed to get the weights of these evaluation parameters and corresponding weighted coefficients of different tracks. Finally, all tracks' information is fused according to the weights of different tracks. The experimental results based on subsets of three public and one private iris image databases demonstrate three contributions of this paper. (1) Our experimental results prove that partial iris image cannot completely replace the entire iris image for iris recognition system in several ways. (2) The proposed quality evaluation algorithm is a self-adaptive algorithm, and it can automatically optimize the parameters according to iris image samples' own characteristics. (3) Our feature information fusion strategy can effectively improve the performance of iris recognition system.

  7. Scale Invariant Gabor Descriptor-Based Noncooperative Iris Recognition

    Directory of Open Access Journals (Sweden)

    Du Yingzi

    2010-01-01

    Full Text Available Abstract A new noncooperative iris recognition method is proposed. In this method, the iris features are extracted using a Gabor descriptor. The feature extraction and comparison are scale, deformation, rotation, and contrast-invariant. It works with off-angle and low-resolution iris images. The Gabor wavelet is incorporated with scale-invariant feature transformation (SIFT for feature extraction to better extract the iris features. Both the phase and magnitude of the Gabor wavelet outputs were used in a novel way for local feature point description. Two feature region maps were designed to locally and globally register the feature points and each subregion in the map is locally adjusted to the dilation/contraction/deformation. We also developed a video-based non-cooperative iris recognition system by integrating video-based non-cooperative segmentation, segmentation evaluation, and score fusion units. The proposed method shows good performance for frontal and off-angle iris matching. Video-based recognition methods can improve non-cooperative iris recognition accuracy.

  8. Scale Invariant Gabor Descriptor-based Noncooperative Iris Recognition

    Directory of Open Access Journals (Sweden)

    Zhi Zhou

    2010-01-01

    Full Text Available A new noncooperative iris recognition method is proposed. In this method, the iris features are extracted using a Gabor descriptor. The feature extraction and comparison are scale, deformation, rotation, and contrast-invariant. It works with off-angle and low-resolution iris images. The Gabor wavelet is incorporated with scale-invariant feature transformation (SIFT for feature extraction to better extract the iris features. Both the phase and magnitude of the Gabor wavelet outputs were used in a novel way for local feature point description. Two feature region maps were designed to locally and globally register the feature points and each subregion in the map is locally adjusted to the dilation/contraction/deformation. We also developed a video-based non-cooperative iris recognition system by integrating video-based non-cooperative segmentation, segmentation evaluation, and score fusion units. The proposed method shows good performance for frontal and off-angle iris matching. Video-based recognition methods can improve non-cooperative iris recognition accuracy.

  9. FAST DISCRETE CURVELET TRANSFORM BASED ANISOTROPIC FEATURE EXTRACTION FOR IRIS RECOGNITION

    Directory of Open Access Journals (Sweden)

    Amol D. Rahulkar

    2010-11-01

    Full Text Available The feature extraction plays a very important role in iris recognition. Recent researches on multiscale analysis provide good opportunity to extract more accurate information for iris recognition. In this work, a new directional iris texture features based on 2-D Fast Discrete Curvelet Transform (FDCT is proposed. The proposed approach divides the normalized iris image into six sub-images and the curvelet transform is applied independently on each sub-image. The anisotropic feature vector for each sub-image is derived using the directional energies of the curvelet coefficients. These six feature vectors are combined to create the resultant feature vector. During recognition, the nearest neighbor classifier based on Euclidean distance has been used for authentication. The effectiveness of the proposed approach has been tested on two different databases namely UBIRIS and MMU1. Experimental results show the superiority of the proposed approach.

  10. Iris recognition in less constrained environments: a video-based approach

    OpenAIRE

    Mahadeo, Nitin Kumar

    2017-01-01

    This dissertation focuses on iris biometrics. Although the iris is the most accurate biometric, its adoption has been relatively slow. Conventional iris recognition systems utilize still eye images captured in ideal environments and require highly constrained subject presentation. A drop in recognition performance is observed when these constraints are removed as the quality of the data acquired is affected by heterogeneous factors. For iris recognition to be widely adopted, it can therefore ...

  11. Gaze Estimation for Off-Angle Iris Recognition Based on the Biometric Eye Model

    Energy Technology Data Exchange (ETDEWEB)

    Karakaya, Mahmut [ORNL; Barstow, Del R [ORNL; Santos-Villalobos, Hector J [ORNL; Thompson, Joseph W [ORNL; Bolme, David S [ORNL; Boehnen, Chris Bensing [ORNL

    2013-01-01

    Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ANONYMIZED biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction from elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.

  12. Brand trust and image: effects on customer satisfaction.

    Science.gov (United States)

    Khodadad Hosseini, Sayed Hamid; Behboudi, Leila

    2017-08-14

    Purpose The purpose of this paper is to investigate brand trust and brand image effects on healthcare service users. Nowadays, managers and health activists are showing increased tendency to marketing and branding to attract and satisfy customers. Design/methodology/approach The current study's design is based on a conceptual model examining brand trust and brand image effects on customer satisfaction. Data obtained from 240 questionnaires (310 respondents) were analyzed using path analysis. Findings Results revealed that the most effective items bearing the highest influence on customer satisfaction and on benefiting from healthcare services include brand image, staff sincerity to its patients, interactions with physicians and rapport. Research limitations/implications This study needs to be conducted in different hospitals and with different patients, which would lead to the model's expansion and its influence on the patient satisfaction. Originality/value Being the first study that simultaneously addresses brand trust and brand image effects on customer satisfaction, this research provides in-depth insights into healthcare marketing. Moreover, identifying significant components associated with healthcare branding helps managers and healthcare activists to create and protect their brands and, consequently, leading to an increased profitability resulting from the enhanced consumer satisfaction. Additionally, it would probably facilitate purchasing processes during the service selection.

  13. The effect of gender on eye colour variation in European populations and an evaluation of the IrisPlex prediction model

    DEFF Research Database (Denmark)

    Pietroni, Carlotta; Andersen, Jeppe D.; Johansen, Peter

    2014-01-01

    In two recent studies of Spanish individuals [1,2], gender was suggested as a factor that contributes to human eye colour variation. However, gender did not improve the predictive accuracy on blue, intermediate and brown eye colours when gender was included in the IrisPlex model [3]. In this stud...... and their corresponding predictive values using the IrisPlex prediction model [4]. The results suggested that maximum three (rs12913832, rs1800407, rs16891982) of the six IrisPlex SNPs are useful in practical forensic genetic casework.......In two recent studies of Spanish individuals [1,2], gender was suggested as a factor that contributes to human eye colour variation. However, gender did not improve the predictive accuracy on blue, intermediate and brown eye colours when gender was included in the IrisPlex model [3]. In this study......12203592). A quantitative eye colour score (Pixel Index of the Eye: PIE-score) was calculated based on digital eye images using the custom made DIAT software. The results were compared with those of Danish and Swedish population samples. As expected, we found HERC2 rs12913832 as the main predictor of human...

  14. Eyelid Localization for Iris Identification

    Directory of Open Access Journals (Sweden)

    T. Ea

    2008-12-01

    Full Text Available This article presents a new eyelid localization algorithm based on a parabolic curve fitting. To deal with eyelashes, low contrast or false detection due to iris texture, we propose a two steps algorithm. First, possible edge candidates are selected by applying edge detection on a restricted area inside the iris. Then, a gradient maximization is applied along every parabola, on a larger area, to refine parameters and select the best one. Experiments have been conducted on a database of 151 iris that have been manually segmented. The performance evaluation is carried out by comparing the segmented images obtained by the proposed method with the manual segmentation. The results are satisfactory in more than 90% of the cases.

  15. IRIS COLOUR CLASSIFICATION SCALES – THEN AND NOW

    Science.gov (United States)

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual’s eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale. PMID:27373112

  16. Eclipse-Free-Time Assessment Tool for IRIS

    Science.gov (United States)

    Eagle, David

    2012-01-01

    IRIS_EFT is a scientific simulation that can be used to perform an Eclipse-Free- Time (EFT) assessment of IRIS (Infrared Imaging Surveyor) mission orbits. EFT is defined to be those time intervals longer than one day during which the IRIS spacecraft is not in the Earth s shadow. Program IRIS_EFT implements a special perturbation of orbital motion to numerically integrate Cowell's form of the system of differential equations. Shadow conditions are predicted by embedding this integrator within Brent s method for finding the root of a nonlinear equation. The IRIS_EFT software models the effects of the following types of orbit perturbations on the long-term evolution and shadow characteristics of IRIS mission orbits. (1) Non-spherical Earth gravity, (2) Atmospheric drag, (3) Point-mass gravity of the Sun, and (4) Point-mass gravity of the Moon. The objective of this effort was to create an in-house computer program that would perform eclipse-free-time analysis. of candidate IRIS spacecraft mission orbits in an accurate and timely fashion. The software is a suite of Fortran subroutines and data files organized as a "computational" engine that is used to accurately predict the long-term orbit evolution of IRIS mission orbits while searching for Earth shadow conditions.

  17. Novel Iris Biometric Watermarking Based on Singular Value Decomposition and Discrete Cosine Transform

    Directory of Open Access Journals (Sweden)

    Jinyu Lu

    2014-01-01

    Full Text Available A novel iris biometric watermarking scheme is proposed focusing on iris recognition instead of the traditional watermark for increasing the security of the digital products. The preprocess of iris image is to be done firstly, which generates the iris biometric template from person's eye images. And then the templates are to be on discrete cosine transform; the value of the discrete cosine is encoded to BCH error control coding. The host image is divided into four areas equally correspondingly. The BCH codes are embedded in the singular values of each host image's coefficients which are obtained through discrete cosine transform (DCT. Numerical results reveal that proposed method can extract the watermark effectively and illustrate its security and robustness.

  18. Cross-sensor iris recognition through kernel learning.

    Science.gov (United States)

    Pillai, Jaishanker K; Puertas, Maria; Chellappa, Rama

    2014-01-01

    Due to the increasing popularity of iris biometrics, new sensors are being developed for acquiring iris images and existing ones are being continuously upgraded. Re-enrolling users every time a new sensor is deployed is expensive and time-consuming, especially in applications with a large number of enrolled users. However, recent studies show that cross-sensor matching, where the test samples are verified using data enrolled with a different sensor, often lead to reduced performance. In this paper, we propose a machine learning technique to mitigate the cross-sensor performance degradation by adapting the iris samples from one sensor to another. We first present a novel optimization framework for learning transformations on iris biometrics. We then utilize this framework for sensor adaptation, by reducing the distance between samples of the same class, and increasing it between samples of different classes, irrespective of the sensors acquiring them. Extensive evaluations on iris data from multiple sensors demonstrate that the proposed method leads to improvement in cross-sensor recognition accuracy. Furthermore, since the proposed technique requires minimal changes to the iris recognition pipeline, it can easily be incorporated into existing iris recognition systems.

  19. [The automatic iris map overlap technology in computer-aided iridiagnosis].

    Science.gov (United States)

    He, Jia-feng; Ye, Hu-nian; Ye, Miao-yuan

    2002-11-01

    In the paper, iridology and computer-aided iridiagnosis technologies are briefly introduced and the extraction method of the collarette contour is then investigated. The iris map can be overlapped on the original iris image based on collarette contour extraction. The research on collarette contour extraction and iris map overlap is of great importance to computer-aided iridiagnosis technologies.

  20. VASIR: An Open-Source Research Platform for Advanced Iris Recognition Technologies.

    Science.gov (United States)

    Lee, Yooyoung; Micheals, Ross J; Filliben, James J; Phillips, P Jonathon

    2013-01-01

    The performance of iris recognition systems is frequently affected by input image quality, which in turn is vulnerable to less-than-optimal conditions due to illuminations, environments, and subject characteristics (e.g., distance, movement, face/body visibility, blinking, etc.). VASIR (Video-based Automatic System for Iris Recognition) is a state-of-the-art NIST-developed iris recognition software platform designed to systematically address these vulnerabilities. We developed VASIR as a research tool that will not only provide a reference (to assess the relative performance of alternative algorithms) for the biometrics community, but will also advance (via this new emerging iris recognition paradigm) NIST's measurement mission. VASIR is designed to accommodate both ideal (e.g., classical still images) and less-than-ideal images (e.g., face-visible videos). VASIR has three primary modules: 1) Image Acquisition 2) Video Processing, and 3) Iris Recognition. Each module consists of several sub-components that have been optimized by use of rigorous orthogonal experiment design and analysis techniques. We evaluated VASIR performance using the MBGC (Multiple Biometric Grand Challenge) NIR (Near-Infrared) face-visible video dataset and the ICE (Iris Challenge Evaluation) 2005 still-based dataset. The results showed that even though VASIR was primarily developed and optimized for the less-constrained video case, it still achieved high verification rates for the traditional still-image case. For this reason, VASIR may be used as an effective baseline for the biometrics community to evaluate their algorithm performance, and thus serves as a valuable research platform.

  1. Iris-based medical analysis by geometric deformation features.

    Science.gov (United States)

    Ma, Lin; Zhang, D; Li, Naimin; Cai, Yan; Zuo, Wangmeng; Wang, Kuanguan

    2013-01-01

    Iris analysis studies the relationship between human health and changes in the anatomy of the iris. Apart from the fact that iris recognition focuses on modeling the overall structure of the iris, iris diagnosis emphasizes the detecting and analyzing of local variations in the characteristics of irises. This paper focuses on studying the geometrical structure changes in irises that are caused by gastrointestinal diseases, and on measuring the observable deformations in the geometrical structures of irises that are related to roundness, diameter and other geometric forms of the pupil and the collarette. Pupil and collarette based features are defined and extracted. A series of experiments are implemented on our experimental pathological iris database, including manual clustering of both normal and pathological iris images, manual classification by non-specialists, manual classification by individuals with a medical background, classification ability verification for the proposed features, and disease recognition by applying the proposed features. The results prove the effectiveness and clinical diagnostic significance of the proposed features and a reliable recognition performance for automatic disease diagnosis. Our research results offer a novel systematic perspective for iridology studies and promote the progress of both theoretical and practical work in iris diagnosis.

  2. Iris recognition in the presence of ocular disease.

    Science.gov (United States)

    Aslam, Tariq Mehmood; Tan, Shi Zhuan; Dhillon, Baljean

    2009-05-06

    Iris recognition systems are among the most accurate of all biometric technologies with immense potential for use in worldwide security applications. This study examined the effect of eye pathology on iris recognition and in particular whether eye disease could cause iris recognition systems to fail. The experiment involved a prospective cohort of 54 patients with anterior segment eye disease who were seen at the acute referral unit of the Princess Alexandra Eye Pavilion in Edinburgh. Iris camera images were obtained from patients before treatment was commenced and again at follow-up appointments after treatment had been given. The principal outcome measure was that of mathematical difference in the iris recognition templates obtained from patients' eyes before and after treatment of the eye disease. Results showed that the performance of iris recognition was remarkably resilient to most ophthalmic disease states, including corneal oedema, iridotomies (laser puncture of iris) and conjunctivitis. Problems were, however, encountered in some patients with acute inflammation of the iris (iritis/anterior uveitis). The effects of a subject developing anterior uveitis may cause current recognition systems to fail. Those developing and deploying iris recognition should be aware of the potential problems that this could cause to this key biometric technology.

  3. Cosmetic Detection Framework for Face and Iris Biometrics

    Directory of Open Access Journals (Sweden)

    Omid Sharifi

    2018-04-01

    Full Text Available Cosmetics pose challenges to the recognition performance of face and iris biometric systems due to its ability to alter natural facial and iris patterns. Facial makeup and iris contact lens are considered to be commonly applied cosmetics for the face and iris in this study. The present work aims to present a novel solution for the detection of cosmetics in both face and iris biometrics by the fusion of texture, shape and color descriptors of images. The proposed cosmetic detection scheme combines the microtexton information from the local primitives of texture descriptors with the color spaces achieved from overlapped blocks in order to achieve better detection of spots, flat areas, edges, edge ends, curves, appearance and colors. The proposed cosmetic detection scheme was applied to the YMU YouTube makeup database (YMD facial makeup database and IIIT-Delhi Contact Lens iris database. The results demonstrate that the proposed cosmetic detection scheme is significantly improved compared to the other schemes implemented in this study.

  4. IRIS Toxicological Review of Thallium and Compounds ...

    Science.gov (United States)

    Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certain tumors. EPA's assessment of noncancer health effects and carcinogenic potential of thallium compounds was last prepared and added to the IRIS database between 1988 and 1990. The IRIS program is preparing an assessment that will incorporate current health effects information available for thallium and compounds, and current risk assessment methods. The IRIS assessment for thallium compounds will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physiochemical and toxicokinetic properties of a chemical, and its toxicity in humans and experimental systems. The assessment will present reference values for the noncancer effects of thallium compounds (RfD and Rfc), and a cancer assessment. The Toxicological Review and IRIS Summary have been subject to Agency review, Interagency review, and external scientific peer review. The final product will reflect the Agency opinion on the overall toxicity of thallium and compounds. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for thallium and compounds. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effec

  5. Automatic quantification of iris color

    DEFF Research Database (Denmark)

    Christoffersen, S.; Harder, Stine; Andersen, J. D.

    2012-01-01

    regions. The result is a blue-brown ratio for each eye. Furthermore, an image clustering approach has been used with promising results. The approach is based on using a sparse dictionary of feature vectors learned from a training set of iris regions. The feature vectors contain both local structural...... information and colour information. For each iris an explanatory histogram is build, containing information about the weighted occurrence of each visual word. A hierarchical agglomerative clustering of the entire set of photos is performed using the distance between the explanatory histograms. The approach...

  6. Method of preliminary localization of the iris in biometric access control systems

    Science.gov (United States)

    Minacova, N.; Petrov, I.

    2015-10-01

    This paper presents a method of preliminary localization of the iris, based on the stable brightness features of the iris in images of the eye. In tests on images of eyes from publicly available databases method showed good accuracy and speed compared to existing methods preliminary localization.

  7. Iris recognition using possibilistic fuzzy matching on local features.

    Science.gov (United States)

    Tsai, Chung-Chih; Lin, Heng-Yi; Taur, Jinshiuh; Tao, Chin-Wang

    2012-02-01

    In this paper, we propose a novel possibilistic fuzzy matching strategy with invariant properties, which can provide a robust and effective matching scheme for two sets of iris feature points. In addition, the nonlinear normalization model is adopted to provide more accurate position before matching. Moreover, an effective iris segmentation method is proposed to refine the detected inner and outer boundaries to smooth curves. For feature extraction, the Gabor filters are adopted to detect the local feature points from the segmented iris image in the Cartesian coordinate system and to generate a rotation-invariant descriptor for each detected point. After that, the proposed matching algorithm is used to compute a similarity score for two sets of feature points from a pair of iris images. The experimental results show that the performance of our system is better than those of the systems based on the local features and is comparable to those of the typical systems.

  8. HOSPITAL IMAGE AS A MODERATING VARIABLE ON THE EFFECT OF HOSPITAL SERVICE QUALITY ON THE CUSTOMER PERCEIVED VALUE, CUSTOMER TRUST AND CUSTOMER LOYALTY IN HOSPITAL SERVICES

    Directory of Open Access Journals (Sweden)

    Indrianawati Usman

    2017-12-01

    Full Text Available This is an explanatory research, analyzing the hospital image as a moderating variable on the effect of hospital service quality on customer perceived value and trust. Research was conducted at several hospitals in Surabaya Indonesia, especially to outpatients. Data was collected by survey to the outpatients of the hospitals. The purpose of this research was empirically examining the effects of hospital service quality on customer perceived value and customer trust, examine effects of customer perceived value and customer trust on customer loyalty. Moreover This research also examined the variable of hospital image as a moderating variable in the effects of hospital service quality on customer perceived value and customer trust. The result of this research gave a perspective to hospital management about the importance of building patient trust, since trust is very important, even more important than satisfaction level. Further studies with more emphasis on identifying the factors building patient trust to the hospital in order to raise customer loyalty should be conducted.

  9. A multi-approach feature extractions for iris recognition

    Science.gov (United States)

    Sanpachai, H.; Settapong, M.

    2014-04-01

    Biometrics is a promising technique that is used to identify individual traits and characteristics. Iris recognition is one of the most reliable biometric methods. As iris texture and color is fully developed within a year of birth, it remains unchanged throughout a person's life. Contrary to fingerprint, which can be altered due to several aspects including accidental damage, dry or oily skin and dust. Although iris recognition has been studied for more than a decade, there are limited commercial products available due to its arduous requirement such as camera resolution, hardware size, expensive equipment and computational complexity. However, at the present time, technology has overcome these obstacles. Iris recognition can be done through several sequential steps which include pre-processing, features extractions, post-processing, and matching stage. In this paper, we adopted the directional high-low pass filter for feature extraction. A box-counting fractal dimension and Iris code have been proposed as feature representations. Our approach has been tested on CASIA Iris Image database and the results are considered successful.

  10. How customers construct corporate social responsibility images: Testing the moderating role of demographic characteristics

    Directory of Open Access Journals (Sweden)

    Andrea Pérez

    2015-04-01

    Full Text Available This paper discusses the formation process of CSR images from a customer perspective. It analyses the influence of company-CSR coherence, motivational attribution and corporate credibility in the way customers evaluate CSR images in the banking industry. It also describes the impact of customer gender, age and educational level on the formation of CSR images. Results show that CSR images are based on customer perceptions of the company-CSR coherence, the attribution of altruistic motivations and corporate credibility when developing CSR initiatives. The findings also demonstrate that gender, age and educational level do not allow identifying differences in the way customers construct CSR images. Thus, they are not useful in segmenting customers for the design of better CSR and communication strategies.

  11. An iris recognition algorithm based on DCT and GLCM

    Science.gov (United States)

    Feng, G.; Wu, Ye-qing

    2008-04-01

    With the enlargement of mankind's activity range, the significance for person's status identity is becoming more and more important. So many different techniques for person's status identity were proposed for this practical usage. Conventional person's status identity methods like password and identification card are not always reliable. A wide variety of biometrics has been developed for this challenge. Among those biologic characteristics, iris pattern gains increasing attention for its stability, reliability, uniqueness, noninvasiveness and difficult to counterfeit. The distinct merits of the iris lead to its high reliability for personal identification. So the iris identification technique had become hot research point in the past several years. This paper presents an efficient algorithm for iris recognition using gray-level co-occurrence matrix(GLCM) and Discrete Cosine transform(DCT). To obtain more representative iris features, features from space and DCT transformation domain are extracted. Both GLCM and DCT are applied on the iris image to form the feature sequence in this paper. The combination of GLCM and DCT makes the iris feature more distinct. Upon GLCM and DCT the eigenvector of iris extracted, which reflects features of spatial transformation and frequency transformation. Experimental results show that the algorithm is effective and feasible with iris recognition.

  12. High-frequency ultrasound measurements of the normal ciliary body and iris.

    Science.gov (United States)

    Garcia, Julian P S; Spielberg, Leigh; Finger, Paul T

    2011-01-01

    To determine the normal ultrasonographic thickness of the iris and ciliary body. This prospective 35-MHz ultrasonographic study included 80 normal eyes of 40 healthy volunteers. The images were obtained at the 12-, 3-, 6-, and 9-o'clock radial meridians, measured at three locations along the radial length of the iris and at the thickest section of the ciliary body. Mixed model was used to estimate eye site-adjusted means and standard errors and to test the statistical difference of adjusted results. Parameters included mean thickness, standard deviation, and range. Mean thicknesses at the iris root, midway along the radial length of the iris, and at the juxtapupillary margin were 0.4 ± 0.1, 0.5 ± 0.1, and 0.6 ± 0.1 mm, respectively. Those of the ciliary body, ciliary processes, and ciliary body + ciliary processes were 0.7 ± 0.1, 0.6 ± 0.1, and 1.3 ± 0.2 mm, respectively. This study provides standard, normative thickness data for the iris and ciliary body in healthy adults using ultrasonographic imaging. Copyright 2011, SLACK Incorporated.

  13. Multispectral iris recognition based on group selection and game theory

    Science.gov (United States)

    Ahmad, Foysal; Roy, Kaushik

    2017-05-01

    A commercially available iris recognition system uses only a narrow band of the near infrared spectrum (700-900 nm) while iris images captured in the wide range of 405 nm to 1550 nm offer potential benefits to enhance recognition performance of an iris biometric system. The novelty of this research is that a group selection algorithm based on coalition game theory is explored to select the best patch subsets. In this algorithm, patches are divided into several groups based on their maximum contribution in different groups. Shapley values are used to evaluate the contribution of patches in different groups. Results show that this group selection based iris recognition

  14. An Improved Iris Recognition Algorithm Based on Hybrid Feature and ELM

    Science.gov (United States)

    Wang, Juan

    2018-03-01

    The iris image is easily polluted by noise and uneven light. This paper proposed an improved extreme learning machine (ELM) based iris recognition algorithm with hybrid feature. 2D-Gabor filters and GLCM is employed to generate a multi-granularity hybrid feature vector. 2D-Gabor filter and GLCM feature work for capturing low-intermediate frequency and high frequency texture information, respectively. Finally, we utilize extreme learning machine for iris recognition. Experimental results reveal our proposed ELM based multi-granularity iris recognition algorithm (ELM-MGIR) has higher accuracy of 99.86%, and lower EER of 0.12% under the premise of real-time performance. The proposed ELM-MGIR algorithm outperforms other mainstream iris recognition algorithms.

  15. The effect of brand image on customer brand loyalty

    OpenAIRE

    ADONYEVA K.V.

    2012-01-01

    Since the world is a global marketing now it’s getting more difficult for the companies to compete. In order to win the leader position in the marketplace marketing specialists work out different kind of strategies to achieve long lasting success. One of the most significant among these strategies is customer loyalty toward the brand.The primary purpose of this article is to illustrate relationships between the brand image, customer satisfaction and customer loyalty, to summarize information ...

  16. Genetic Background of Iris Melanomas and Iris Melanocytic Tumors of Uncertain Malignant Potential.

    Science.gov (United States)

    van Poppelen, Natasha M; Vaarwater, Jolanda; Mudhar, Hardeep S; Sisley, Karen; Rennie, Ian G; Rundle, Paul; Brands, Tom; van den Bosch, Quincy C C; Mensink, Hanneke W; de Klein, Annelies; Kiliç, Emine; Verdijk, Robert M

    2018-01-19

    Uveal melanoma (UM) is the most common primary intraocular malignancy in adults. Iris melanoma comprises 4% to 10% of all UMs and has a lower mortality rate. The genetic changes in iris melanoma are not as well characterized as ciliary body or choroidal melanoma. The aim of this study was to gain more insight into the genetic background of iris melanoma and iris nevi. Multicenter, retrospective case series. Patients diagnosed with iris melanoma or iris nevi who underwent surgical intervention as primary or secondary treatment. Next-generation sequencing of GNAQ, GNA11, EIF1AX, SF3B1, BAP1, NRAS, BRAF, PTEN, c-Kit, TP53, and TERT was performed on 30 iris melanomas and 7 iris nevi. Copy number status was detected using single nucleotide polymorphisms (SNPs) included in the next-generation sequencing (NGS) panel, SNP array, or fluorescent in situ hybridization. BAP1 immunohistochemistry was performed on all samples. Mutation and copy number status were analyzed. Results of BAP1 immunohistochemistry were used for survival analysis. In 26 of the 30 iris melanoma and all iris nevi, at least 1 mutation was identified. Multiple mutations were detected in 23 iris melanoma and 5 nevi, as well as mutations in GNAQ and GNA11. Furthermore, 13 of 30 BAP1, 5 of 30 EIF1AX, and 2 of 30 SF3B1 mutations were identified in iris melanoma. No correlation between BAP1 status and disease-free survival was found. The iris nevi showed 1 EIF1AX and 3 BAP1 mutations. Two of the nevi, with a BAP1 mutation, were histologically borderline malignant. Mutations in NRAS, BRAF, PTEN, c-KIT, and TP53 were detected in 6 iris melanomas and 4 iris nevi. Mutations that are often found in uveal and cutaneous melanoma were identified in this cohort of iris melanomas and iris nevi. Therefore, iris melanomas harbor a molecular profile comparable to both choroidal melanoma and cutaneous melanoma. These findings may offer adjuvant targeted therapies for iris melanoma. There was no prognostic significance of

  17. Studying the Mediator Role of Customer Based Brand Equity in Successful Customer Relationship and Brand Image of Five Star Hotels in Mashhad

    OpenAIRE

    Fariborz Rahimnia; Seyede Zahra Fatemi

    2012-01-01

    Branding and brand management in the marketing world of today have many followers. In the service sector, brands are treated as a quick way to identify and differentiate themselves and create an image in the minds of their customers. Among the intangible aspects of a product or service, brand image is the most important aspect, which is emphasized in marketing strategies. Service firms try to communicate with their customers and make a desired image in the mind of their customers by influenci...

  18. RELATIONSHIP AMONG CORPORATE IMAGE, INTANGIBLE PERCEIVED QUALITY, CHOOSING, HABIT AND CUSTOMER LOYALTY

    Directory of Open Access Journals (Sweden)

    Maryam REHMAN

    2012-01-01

    Full Text Available This study explores relationships among Corporate Image, Intangible Perceived Quality, Choosing, Habit and Customer Loyalty and investigates the pivotal role these variables play in establishing and maintaining healthy base of loyal customers. Data were collected from Pakistani bank account holders and the empirical findings showed that corporate image plays the most important role in establishing and maintaining customer loyalty in the markets. Organizations always look forward to long lasting success. In order to be successful in the long run, they need to keep abreast with all of their stakeholders. Out of the stakeholders, customers are considered to be the most important one. Customer Loyalty is a psychological motive which today’s managers are considerate about. This study concludes that long-term success and sustainable reputation of an organization depends on customer loyalty.

  19. Fusion of phase congruency and harris algorithm for extraction of iris corner points

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, G

    2015-12-01

    Full Text Available iris identification systems. Low cost devices used under uncontrolled environments acquire poor iris images with inconsistent illumination and specular reflections. These factors inflict challenges towards the accurate identification and extraction...

  20. Improved Iris Recognition through Fusion of Hamming Distance and Fragile Bit Distance.

    Science.gov (United States)

    Hollingsworth, Karen P; Bowyer, Kevin W; Flynn, Patrick J

    2011-12-01

    The most common iris biometric algorithm represents the texture of an iris using a binary iris code. Not all bits in an iris code are equally consistent. A bit is deemed fragile if its value changes across iris codes created from different images of the same iris. Previous research has shown that iris recognition performance can be improved by masking these fragile bits. Rather than ignoring fragile bits completely, we consider what beneficial information can be obtained from the fragile bits. We find that the locations of fragile bits tend to be consistent across different iris codes of the same eye. We present a metric, called the fragile bit distance, which quantitatively measures the coincidence of the fragile bit patterns in two iris codes. We find that score fusion of fragile bit distance and Hamming distance works better for recognition than Hamming distance alone. To our knowledge, this is the first and only work to use the coincidence of fragile bit locations to improve the accuracy of matches.

  1. IRiS: construction of ARG networks at genomic scales.

    Science.gov (United States)

    Javed, Asif; Pybus, Marc; Melé, Marta; Utro, Filippo; Bertranpetit, Jaume; Calafell, Francesc; Parida, Laxmi

    2011-09-01

    Given a set of extant haplotypes IRiS first detects high confidence recombination events in their shared genealogy. Next using the local sequence topology defined by each detected event, it integrates these recombinations into an ancestral recombination graph. While the current system has been calibrated for human population data, it is easily extendible to other species as well. IRiS (Identification of Recombinations in Sequences) binary files are available for non-commercial use in both Linux and Microsoft Windows, 32 and 64 bit environments from https://researcher.ibm.com/researcher/view_project.php?id = 2303 parida@us.ibm.com.

  2. IRIS

    International Nuclear Information System (INIS)

    Malfaro, W.; Zygmont, A.

    1991-01-01

    This paper discusses development of ISOLATION RESET INFORMATION SYSTEM (IRIS), an expert system to aid nuclear plant operators during plant transients known as automatic containment isolations. IRIS is implemented using the Personal Consultant Plus expert system shell, taking advantage of the dBase III Plus interface. The design of IRIS is discussed as well as the system's current state of development. The use of expert systems for training operators is discussed. The importance of gaining regulatory acceptance of expert systems is presented. This issue will ultimately determine the extent of expert system use in nuclear applications

  3. The Effect of Relationship Marketing and Brand Image on Customer Loyalty (Case of Astinet Business Customer PT Telkom Witel Makassar)

    OpenAIRE

    Andi Nur Qalby; Abdul Razak Munir; Jusni Jusni

    2018-01-01

    Marketing is an activity that can penetrate space and time. This study aims to determine to know the influence of Relationship Marketing and Brand Image Against Customer Loyalty at PT Telkom Witel Makassar. This type of research is causal (causal relationship research), which is trying to find the relationship of influence between relationship marketing and brand image with customer satisfaction and loyalty ASTINet users. The results showed that Relationship marketing and Brand image have pos...

  4. Machine learning techniques for medical diagnosis of diabetes using iris images.

    Science.gov (United States)

    Samant, Piyush; Agarwal, Ravinder

    2018-04-01

    Complementary and alternative medicine techniques have shown their potential for the treatment and diagnosis of chronical diseases like diabetes, arthritis etc. On the same time digital image processing techniques for disease diagnosis is reliable and fastest growing field in biomedical. Proposed model is an attempt to evaluate diagnostic validity of an old complementary and alternative medicine technique, iridology for diagnosis of type-2 diabetes using soft computing methods. Investigation was performed over a close group of total 338 subjects (180 diabetic and 158 non-diabetic). Infra-red images of both the eyes were captured simultaneously. The region of interest from the iris image was cropped as zone corresponds to the position of pancreas organ according to the iridology chart. Statistical, texture and discrete wavelength transformation features were extracted from the region of interest. The results show best classification accuracy of 89.63% calculated from RF classifier. Maximum specificity and sensitivity were absorbed as 0.9687 and 0.988, respectively. Results have revealed the effectiveness and diagnostic significance of proposed model for non-invasive and automatic diabetes diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. IRIS Licensing Status

    International Nuclear Information System (INIS)

    Kling, Charles L.; Carelli, Mario D.

    2006-01-01

    The International Reactor Innovative and Secure (IRIS) nuclear power plant is well into the pre-application review process with the US NRC and has accomplished its first near term goal of obtaining US NRC feedback on the long term testing program. To date, the IRIS team has submitted to the US NRC a number of documents patterned after the Evaluation Model Development and Assessment Process (EMDAP) outlined in Regulatory Guide 1,203. They have covered a detailed description of IRIS, initial safety analysis results, PIRT development for limiting transients, scaling analysis and a description of the test program. The IRIS Safety-by-Desing TM intrinsically eliminates and/or significantly reduces the consequences of traditional LWR accidents. In addition, the fewer passive safety systems are similar in principle to those of the US NRC approved AP1000 design. For these reasons, the IRIS testing program only needs to include those features unique to the IRIS design. NRC feedback was that the planned test program appeared to be complete and could generate sufficient information to support a Design Certification (DC) submittal. The US NRC has also stated that a DC application must include complete information regarding the test program. On this basis the IRIS team has initiated an aggressive program to conduct IRIS testing to support a DC submittal by the end of 2008. Subsequent US NRC review should be expeditious because of the AP1000 precedent, allowing IRIS to obtain its Final Design Approval (FDA) in 2012; thereby, maintaining its goal of deployment in the 2015-2017 time frame. The next steps in the pre-application review process will be to provide the US NRC with a road map of the anticipated IRIS licensing process, a review of current licensing requirements showing that IRIS meets or exceeds all current criteria and information to support the long term goal of redefining the Emergency Planning Zone (EPZ)

  6. The Effect of Islamic Marketing and Corporate Image on Customer Satisfaction and Customer Loyalty (Study on Customers of PT Bank Muamalat Indonesia Malang Branch Office)

    OpenAIRE

    Setyono, Langgeng

    2015-01-01

    The aim of this research was to examine the effect of Islamic marketing and corporate image on customer satisfaction and customer loyalty. This research used explanatory research and quantitative approach. Population in this research was customers of saving product in Bank Muamalat Indonesia Malang Branch Office. Questionnaires were distributed to 138 respondents by purposive sampling technique. Data analysis technique involved path analysis and descriptive analysis. Based on calculation of p...

  7. Ethnicity prediction and classification from iris texture patterns: A survey on recent advances

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, Gugulethu

    2017-03-01

    Full Text Available The prediction and classification of ethnicity based on iris texture patterns using image processing, artificial intelligence and computer vision techniques is still a recent topic in iris biometrics. While the large body of knowledge and research...

  8. Trade off between variable and fixed size normalization in orthogonal polynomials based iris recognition system.

    Science.gov (United States)

    Krishnamoorthi, R; Anna Poorani, G

    2016-01-01

    Iris normalization is an important stage in any iris biometric, as it has a propensity to trim down the consequences of iris distortion. To indemnify the variation in size of the iris owing to the action of stretching or enlarging the pupil in iris acquisition process and camera to eyeball distance, two normalization schemes has been proposed in this work. In the first method, the iris region of interest is normalized by converting the iris into the variable size rectangular model in order to avoid the under samples near the limbus border. In the second method, the iris region of interest is normalized by converting the iris region into a fixed size rectangular model in order to avoid the dimensional discrepancies between the eye images. The performance of the proposed normalization methods is evaluated with orthogonal polynomials based iris recognition in terms of FAR, FRR, GAR, CRR and EER.

  9. Increasing the information acquisition volume in iris recognition systems.

    Science.gov (United States)

    Barwick, D Shane

    2008-09-10

    A significant hurdle for the widespread adoption of iris recognition in security applications is that the typically small imaging volume for eye placement results in systems that are not user friendly. Separable cubic phase plates at the lens pupil have been shown to ameliorate this disadvantage by increasing the depth of field. However, these phase masks have limitations on how efficiently they can capture the information-bearing spatial frequencies in iris images. The performance gains in information acquisition that can be achieved by more general, nonseparable phase masks is demonstrated. A detailed design method is presented, and simulations using representative designs allow for performance comparisons.

  10. ANTIMICROBIAL ACTIVITY OF EXTRACTS OF IRIS HUNGARICA AND IRIS SIBIRICA

    Directory of Open Access Journals (Sweden)

    Kovalev V. M.

    2017-06-01

    Full Text Available Introduction. Referring to the latest data, infectious diseases command a large part of among the total number of pathologies in the world and are an important problem in medicine. The leading role in prevention and treatment of diseases of microbial origin belongs to antibacterial chemotherapeutic agents. Advantages of antibiotics of synthetic origin are the high activity compared to phytogenic drugs. But it is known that microorganisms can release the resistance to synthetic antibiotics, so the use of drugs based on the plant materials is appropriate: phytogenic drugs more rarely induce the formation of resistance of the strains of microorganisms, they have a gentle action, can be used for a long-term, have the low cost. Therefore, it is appropriate to examine the drug plants with the aim of determination their antibacterial activity.Iris hungarica Waldst et Kit. and Iris sibirica L. are the representatives of the family Iridaceae, genus Iris and they have a wide spectrum of the pharmacological activity. Biologically active substances that were recovered from plants of the genus Iris (tectoridin, iristectorigenin B, nigracin, kaempferol, quercetin, etc. exhibited an antitumor, antimicrobial, estrogenic, insecticidal, antiplasmatic, anticholinesterase action, they were the inhibitors of enzymes and exhibited the immunomodulatory properties, which made these plants perspective for the research study. Raw materials Irises are constituent components of more than 9 medicines. Materials and Methods. The objects of the study were the leaves and rhizomes of Iris hungarica and Iris sibirica that were prepared during the growing season in 2014 in the M.M. Gryshko National botanical garden (Kiev, Ukraine. The dry and lipophilic extracts from the leaves and rhizomes of Irises were used to establish the antimicrobial activity. For the study of extracts antimicrobial activity was used agar well diffusion method. According to the WHO recommendations the

  11. RELATIONSHIP COMMITMENT, RELATIONAL EQUITY AND COMPANY IMAGE IN CUSTOMER LOYALTY DEVELOPMENT

    OpenAIRE

    DLAČIĆ, JASMINA; ŽABKAR, VESNA

    2012-01-01

    This paper explores the relationship between customer loyalty and its seldom researched antecedents: relationship commitment, relational equity and company image. The proposed conceptual model is tested with data gained from customers of mobile telephone operators. The results show that relationship commitment and relational equity have a statistically significant positive influence on customer loyalty. In addition, the results of hierarchical multiple regr...

  12. Optical Coherence Tomography Angiography Features of Iris Racemose Hemangioma in 4 Cases.

    Science.gov (United States)

    Chien, Jason L; Sioufi, Kareem; Ferenczy, Sandor; Say, Emil Anthony T; Shields, Carol L

    2017-10-01

    Optical coherence tomography angiography (OCTA) allows visualization of iris racemose hemangioma course and its relation to the normal iris microvasculature. To describe OCTA features of iris racemose hemangioma. Descriptive, noncomparative case series at a tertiary referral center (Ocular Oncology Service of Wills Eye Hospital). Patients diagnosed with unilateral iris racemose hemangioma were included in the study. Features of iris racemose hemangioma on OCTA. Four eyes of 4 patients with unilateral iris racemose hemangioma were included in the study. Mean patient age was 50 years, all patients were white, and Snellen visual acuity was 20/20 in each case. All eyes had sectoral iris racemose hemangioma without associated iris or ciliary body solid tumor on clinical examination and ultrasound biomicroscopy. By anterior segment OCT, the racemose hemangioma was partially visualized in all cases. By OCTA, the hemangioma was clearly visualized as a uniform large-caliber vascular tortuous loop with intense flow characteristics superimposed over small-caliber radial iris vessels against a background of low-signal iris stroma. The vascular course on OCTA resembled a light bulb filament (filament sign), arising from the peripheral iris (base of light bulb) and forming a tortuous loop on reaching its peak (midfilament) near the pupil (n = 3) or midzonal iris (n = 1), before returning to the peripheral iris (base of light bulb). Intravenous fluorescein angiography performed in 1 eye depicted the iris hemangioma; however, small-caliber radial iris vessels were more distinct on OCTA than intravenous fluorescein angiography. Optical coherence tomography angiography is a noninvasive vascular imaging modality that clearly depicts the looping course of iris racemose hemangioma. Optical coherence tomography angiography depicted fine details of radial iris vessels, not distinct on intravenous fluorescein angiography.

  13. Detection of trace explosives on relevant substrates using a mobile platform for photothermal infrared imaging spectroscopy (PT-IRIS)

    Science.gov (United States)

    Kendziora, Christopher A.; Furstenberg, Robert; Papantonakis, Michael; Nguyen, Viet; Byers, Jeff; McGill, R. Andrew

    2015-05-01

    This manuscript describes the results of recent tests regarding standoff detection of trace explosives on relevant substrates using a mobile platform. We are developing a technology for detection based on photo-thermal infrared (IR) imaging spectroscopy (PT-IRIS). This approach leverages one or more microfabricated IR quantum cascade lasers, tuned to strong absorption bands in the analytes and directed to illuminate an area on a surface of interest. An IR focal plane array is used to image the surface thermal emission upon laser illumination. The PT-IRIS signal is processed as a hyperspectral image cube comprised of spatial, spectral and temporal dimensions as vectors within a detection algorithm. Increased sensitivity to explosives and selectivity between different analyte types is achieved by narrow bandpass IR filters in the collection path. We have previously demonstrated the technique at several meters of stand-off distance indoors and in field tests, while operating the lasers below the infrared eye-safe intensity limit (100 mW/cm2). Sensitivity to explosive traces as small as a single 10 μm diameter particle (~1 ng) has been demonstrated. Analytes tested here include RDX, TNT, ammonium nitrate and sucrose. The substrates tested in this current work include metal, plastics, glass and painted car panels.

  14. Evaluation of the Successfulness of A Green Program through Customer Perceived Quality, Brand Image, and Customer Satisfaction: A Case Study at Surabaya Plaza Hotel

    Directory of Open Access Journals (Sweden)

    Marsella Yeanette Hatane

    2012-01-01

    Full Text Available Every company try to build the brand image of their businesses by doing a green program as one of their strategies. This research aims to see the impacts of the implementation of a green program at Surabaya Plaza Hotel, Surabaya. 230 hotel customers were randomly chosen as the respondents. Through descriptive and Structural Equation Modelling (SEM analysis, can be seen that technical quality brings insignificant negative impacts towards customer satisfaction. Meanwhile, functional quality and brand image bring a significant positive impact toward customer satisfaction. Besides that, technical quality and functional quality bring a significant positive effect indirectly toward customer satisfaction through brand image as mediating.

  15. Frontal view reconstruction for iris recognition

    Science.gov (United States)

    Santos-Villalobos, Hector J; Bolme, David S; Boehnen, Chris Bensing

    2015-02-17

    Iris recognition can be accomplished for a wide variety of eye images by correcting input images with an off-angle gaze. A variety of techniques, from limbus modeling, corneal refraction modeling, optical flows, and genetic algorithms can be used. A variety of techniques, including aspherical eye modeling, corneal refraction modeling, ray tracing, and the like can be employed. Precomputed transforms can enhance performance for use in commercial applications. With application of the technologies, images with significantly unfavorable gaze angles can be successfully recognized.

  16. The effect of gender on eye colour variation in European populations and an evaluation of the IrisPlex prediction model.

    Science.gov (United States)

    Pietroni, Carlotta; Andersen, Jeppe D; Johansen, Peter; Andersen, Mikkel M; Harder, Stine; Paulsen, Rasmus; Børsting, Claus; Morling, Niels

    2014-07-01

    In two recent studies of Spanish individuals, gender was suggested as a factor that contributes to human eye colour variation. However, gender did not improve the predictive accuracy on blue, intermediate and brown eye colours when gender was included in the IrisPlex model. In this study, we investigate the role of gender as a factor that contributes to eye colour variation and suggest that the gender effect on eye colour is population specific. A total of 230 Italian individuals were typed for the six IrisPlex SNPs (rs12913832, rs1800407, rs12896399, rs1393350, rs16891982 and rs12203592). A quantitative eye colour score (Pixel Index of the Eye: PIE-score) was calculated based on digital eye images using the custom made DIAT software. The results were compared with those of Danish and Swedish population samples. As expected, we found HERC2 rs12913832 as the main predictor of human eye colour independently of ancestry. Furthermore, we found gender to be significantly associated with quantitative eye colour measurements in the Italian population sample. We found that the association was statistically significant only among Italian individuals typed as heterozygote GA for HERC2 rs12913832. Interestingly, we did not observe the same association in the Danish and Swedish population. This indicated that the gender effect on eye colour is population specific. We estimated the effect of gender on quantitative eye colour in the Italian population sample to be 4.9%. Among gender and the IrisPlex SNPs, gender ranked as the second most important predictor of human eye colour variation in Italians after HERC2 rs12913832. We, furthermore, tested the five lower ranked IrisPlex predictors, and evaluated all possible 3(6) (729) genotype combinations of the IrisPlex assay and their corresponding predictive values using the IrisPlex prediction model [4]. The results suggested that maximum three (rs12913832, rs1800407, rs16891982) of the six IrisPlex SNPs are useful in practical

  17. Modeling IrisCode and its variants as convex polyhedral cones and its security implications.

    Science.gov (United States)

    Kong, Adams Wai-Kin

    2013-03-01

    IrisCode, developed by Daugman, in 1993, is the most influential iris recognition algorithm. A thorough understanding of IrisCode is essential, because over 100 million persons have been enrolled by this algorithm and many biometric personal identification and template protection methods have been developed based on IrisCode. This paper indicates that a template produced by IrisCode or its variants is a convex polyhedral cone in a hyperspace. Its central ray, being a rough representation of the original biometric signal, can be computed by a simple algorithm, which can often be implemented in one Matlab command line. The central ray is an expected ray and also an optimal ray of an objective function on a group of distributions. This algorithm is derived from geometric properties of a convex polyhedral cone but does not rely on any prior knowledge (e.g., iris images). The experimental results show that biometric templates, including iris and palmprint templates, produced by different recognition methods can be matched through the central rays in their convex polyhedral cones and that templates protected by a method extended from IrisCode can be broken into. These experimental results indicate that, without a thorough security analysis, convex polyhedral cone templates cannot be assumed secure. Additionally, the simplicity of the algorithm implies that even junior hackers without knowledge of advanced image processing and biometric databases can still break into protected templates and reveal relationships among templates produced by different recognition methods.

  18. Exploring the impact of brand image on customer loyalty and commitment in China

    OpenAIRE

    Ogba, Ike; Tan, Zhenzhen

    2009-01-01

    Purpose – Whereas there is a growing recognition of the relevance of brand image to the success of market offering and organisation, as indications suggests that a good brand image can enhance customer experience and satisfaction for long-term commitment. Evidences suggest limited study on the impact of brand image on key marketing and organisational components, including the impact of brand image on customer loyalty and commitment. The purpose of this study is, therefore, to examine how bran...

  19. The influence of store image on customer satisfaction: a case study of a shoe store

    Directory of Open Access Journals (Sweden)

    Tarsis Souza Silva

    2010-01-01

    Full Text Available Knowledge of customers' image of a store is an essential factor in the management of retail outlets. This article presents a case study of the effect of the image customers have of a shoe store on their satisfaction, based on a descriptive and quantitative survey, with the application of a structured questionnaire. We then employed factor analysis to obtain seven store image factors: assortment, convenience, reputation, price, atmosphere, layout and service. The results show that the factor that most affects customer satisfaction in the store studied is service, and that atmosphere and layout have no effect in this respect. The results provide a better understanding of the role store image plays in customer satisfaction and loyalty.

  20. Wavelet Types Comparison for Extracting Iris Feature Based on Energy Compaction

    Science.gov (United States)

    Rizal Isnanto, R.

    2015-06-01

    Human iris has a very unique pattern which is possible to be used as a biometric recognition. To identify texture in an image, texture analysis method can be used. One of method is wavelet that extract the image feature based on energy. Wavelet transforms used are Haar, Daubechies, Coiflets, Symlets, and Biorthogonal. In the research, iris recognition based on five mentioned wavelets was done and then comparison analysis was conducted for which some conclusions taken. Some steps have to be done in the research. First, the iris image is segmented from eye image then enhanced with histogram equalization. The features obtained is energy value. The next step is recognition using normalized Euclidean distance. Comparison analysis is done based on recognition rate percentage with two samples stored in database for reference images. After finding the recognition rate, some tests are conducted using Energy Compaction for all five types of wavelets above. As the result, the highest recognition rate is achieved using Haar, whereas for coefficients cutting for C(i) < 0.1, Haar wavelet has a highest percentage, therefore the retention rate or significan coefficient retained for Haaris lower than other wavelet types (db5, coif3, sym4, and bior2.4)

  1. Effect of cataract surgery and pupil dilation on iris pattern recognition for personal authentication.

    Science.gov (United States)

    Dhir, L; Habib, N E; Monro, D M; Rakshit, S

    2010-06-01

    The purpose of this study was to investigate the effect of cataract surgery and pupil dilation on iris pattern recognition for personal authentication. Prospective non-comparative cohort study. Images of 15 subjects were captured before (enrolment), and 5, 10, and 15 min after instillation of mydriatics before routine cataract surgery. After cataract surgery, images were captured 2 weeks thereafter. Enrolled and test images (after pupillary dilation and after cataract surgery) were segmented to extract the iris. This was then unwrapped onto a rectangular format for normalization and a novel method using the Discrete Cosine Transform was applied to encode the image into binary bits. The numerical difference between two iris codes (Hamming distance, HD) was calculated. The HD between identification and enrolment codes was used as a score and was compared with a confidence threshold for specific equipment, giving a match or non-match result. The Correct Recognition Rate (CRR) and Equal Error Rates (EERs) were calculated to analyse overall system performance. After cataract surgery, perfect identification and verification was achieved, with zero false acceptance rate, zero false rejection rate, and zero EER. After pupillary dilation, non-elastic deformation occurs and a CRR of 86.67% and EER of 9.33% were obtained. Conventional circle-based localization methods are inadequate. Matching reliability decreases considerably with increase in pupillary dilation. Cataract surgery has no effect on iris pattern recognition, whereas pupil dilation may be used to defeat an iris-based authentication system.

  2. HOSPITAL IMAGE AS A MODERATING VARIABLE ON THE EFFECT OF HOSPITAL SERVICE QUALITY ON THE CUSTOMER PERCEIVED VALUE, CUSTOMER TRUST AND CUSTOMER LOYALTY IN HOSPITAL SERVICES

    OpenAIRE

    Indrianawati Usman

    2017-01-01

    This is an explanatory research, analyzing the hospital image as a moderating variable on the effect of hospital service quality on customer perceived value and trust. Research was conducted at several hospitals in Surabaya Indonesia, especially to outpatients. Data was collected by survey to the outpatients of the hospitals. The purpose of this research was empirically examining the effects of hospital service quality on customer perceived value and customer trust, examine eff...

  3. PLATEAU IRIS SYNDROME--CASE SERIES.

    Science.gov (United States)

    Feraru, Crenguta Ioana; Pantalon, Anca Delia; Chiselita, Dorin; Branisteanu, Daniel

    2015-01-01

    Plateau iris is characterized by closing the anterior chamber angle due to a large ciliary body or due to its anterior insertion that alters the position of iris periphery in respect to the trabecular meshwork. There are two aspects that need to be differentiated: plateau iris configuration and plateau iris syndrome. The first describes a situation when the iris root is flat and the anterior chamber is not shallow, the latter refers to a post laser iridotomy condition in which a patent iridotomy has removed the relative pupillary block, but goniscopically confirmed angle closure recurs without central shallowing of the anterior chamber. Isolated plateau iris syndrome is rare compared to plateau iris configuration. We hereby present two case reports of plateau iris syndrome in young patients who came to an ophthalmologic consult by chance.

  4. an enhanced iris recognition and authentication system using ...

    African Journals Online (AJOL)

    Biu et al.

    1Department of Mathematical Sciences, Kaduna State University, Kaduna – Nigeria. (E-mail: ..... localization, the iris is in a circulation fashion then lastly, the image is saved into .... Conference on Computer Engineering Systems. Cleve, K.

  5. Bio-imaging and visualization for patient-customized simulations

    CERN Document Server

    Luo, Xiongbiao; Li, Shuo

    2014-01-01

    This book contains the full papers presented at the MICCAI 2013 workshop Bio-Imaging and Visualization for Patient-Customized Simulations (MWBIVPCS 2013). MWBIVPCS 2013 brought together researchers representing several fields, such as Biomechanics, Engineering, Medicine, Mathematics, Physics and Statistic. The contributions included in this book present and discuss new trends in those fields, using several methods and techniques, including the finite element method, similarity metrics, optimization processes, graphs, hidden Markov models, sensor calibration, fuzzy logic, data mining, cellular automation, active shape models, template matching and level sets. These serve as tools to address more efficiently different and timely applications involving signal and image acquisition, image processing and analysis, image segmentation, image registration and fusion, computer simulation, image based modelling, simulation and surgical planning, image guided robot assisted surgical and image based diagnosis.  This boo...

  6. Coastal and Inland Aquatic Data Products for the Hyperspectral Infrared Imager (HyspIRI)

    Science.gov (United States)

    Abelev, Andrei; Babin, Marcel; Bachmann, Charles; Bell, Thomas; Brando, Vittorio; Byrd, Kristin; Dekker , Arnold; Devred, Emmanuel; Forget, Marie-Helene; Goodman, James; hide

    2015-01-01

    The HyspIRI Aquatic Studies Group (HASG) has developed a conceptual list of data products for the HyspIRI mission to support aquatic remote sensing of coastal and inland waters. These data products were based on mission capabilities, characteristics, and expected performance. The topic of coastal and inland water remote sensing is very broad. Thus, this report focuses on aquatic data products to keep the scope of this document manageable. The HyspIRI mission requirements already include the global production of surface reflectance and temperature. Atmospheric correction and surface temperature algorithms, which are critical to aquatic remote sensing, are covered in other mission documents. Hence, these algorithms and their products were not evaluated in this report. In addition, terrestrial products (e.g., land use land cover, dune vegetation, and beach replenishment) were not considered. It is recognized that coastal studies are inherently interdisciplinary across aquatic and terrestrial disciplines. However, products supporting the latter are expected to already be evaluated by other components of the mission. The coastal and inland water data products that were identified by the HASG, covered six major environmental and ecological areas for scientific research and applications: wetlands, shoreline processes, the water surface, the water column, bathymetry and benthic cover types. Accordingly, each candidate product was evaluated for feasibility based on the HyspIRI mission characteristics and whether it was unique and relevant to the HyspIRI science objectives.

  7. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    International Nuclear Information System (INIS)

    Bieniosek, Matthew F.; Lee, Brian J.; Levin, Craig S.

    2015-01-01

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed

  8. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Bieniosek, Matthew F. [Department of Electrical Engineering, Stanford University, 350 Serra Mall, Stanford, California 94305 (United States); Lee, Brian J. [Department of Mechanical Engineering, Stanford University, 440 Escondido Mall, Stanford, California 94305 (United States); Levin, Craig S., E-mail: cslevin@stanford.edu [Departments of Radiology, Physics, Bioengineering and Electrical Engineering, Stanford University, 300 Pasteur Dr., Stanford, California 94305-5128 (United States)

    2015-10-15

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed

  9. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms.

    Science.gov (United States)

    Bieniosek, Matthew F; Lee, Brian J; Levin, Craig S

    2015-10-01

    Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial "Micro Deluxe" phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. This work shows that 3D printed phantoms can be functionally equivalent to

  10. Applications of custom scripting in digital micrograph: general image manipulation and utilities

    International Nuclear Information System (INIS)

    Mitchell, D.R.G.

    2002-01-01

    Full text: The Gatan Imaging Filter (GIF) uses a charge coupled device (CCD) camera to capture images and spectra. Image capture and manipulation is achieved through Gatan's Digital Micrograph software. This has many capabilities built-in, and can be further extended through installation of custom scripts. These are typically short programs written in a powerful scripting language, which permits many aspects of image acquisition and subsequent manipulation to be controlled by the user. Custom scripts can be added to the normal pull down menus, producing a very flexible and easy to use environment. The scripts described here demonstrate how custom scripting can enhance the functionality of a modem analytical TEM equipped with, in this instance, a GIF. However, scripting will enhance any TEM using a CCD camera controlled through Digital Micrograph. The examples shown here include: a) a script to rotationally average a selected area diffraction pattern and produce a calibrated radial intensity profile, b) a utility script which monitors and graphically displays the CCD temperature as a function of time and c) a simple script to propagate image spatial calibrations to uncalibrated images, such as EFTEM images. Other scripts by the author along with some scripting resources are also discussed. Copyright (2002) Australian Society for Electron Microscopy Inc

  11. Transition-Region Ultraviolet Explosive Events in IRIS Si IV: A Statistical Analysis

    Science.gov (United States)

    Bartz, Allison

    2018-01-01

    Explosive events (EEs) in the solar transition region are characterized by broad, non-Gaussian line profiles with wings at Doppler velocities exceeding the speed of sound. We present a statistical analysis of 23 IRIS (Interface Region Imaging Spectrograph) sit-and-stare observations, observed between April 2014 and March 2017. Using the IRIS Si IV 1394 Å and 1403 Å spectral windows and the 1400Å Slit Jaw images we have identified 581 EEs. We found that most EEs last less than 20 min. and have a spatial scale on the slit less than 10”, agreeing with measurements in previous work. We observed most EEs in active regions, regardless of date of observation, but selection bias of IRIS observations cannot be ruled out. We also present preliminary findings of optical depth effects from our statistical study.

  12. Real-time digital imaging of leukocyte-endothelial interaction in ischemia-reperfusion injury (IRI) of the rat cremaster muscle.

    Science.gov (United States)

    Thiele, Jan R; Goerendt, Kurt; Stark, G Bjoern; Eisenhardt, Steffen U

    2012-08-05

    Ischemia-reperfusion injury (IRI) has been implicated in a large array of pathological conditions such as cerebral stroke, myocardial infarction, intestinal ischemia as well as following transplant and cardiovascular surgery. Reperfusion of previously ischemic tissue, while essential for the prevention of irreversible tissue injury, elicits excessive inflammation of the affected tissue. Adjacent to the production of reactive oxygen species, activation of the complement system and increased microvascular permeability, the activation of leukocytes is one of the principle actors in the pathological cascade of inflammatory tissue damage during reperfusion. Leukocyte activation is a multistep process consisting of rolling, firm adhesion and transmigration and is mediated by a complex interaction between adhesion molecules in response to chemoattractants such as complement factors, chemokines, or platelet-activating factor. While leukocyte rolling in postcapillary venules is predominantly mediated by the interaction of selectins with their counter ligands, firm adhesion of leukocytes to the endothelium is selectin-controlled via binding to intercellular adhesion molecules (ICAM) and vascular cellular adhesion molecules (VCAM). Gold standard for the in vivo observation of leukocyte-endothelial interaction is the technique of intravital microscopy, first described in 1968. Though various models of IRI (ischemia-reperfusion injury) have been described for various organs, only few are suitable for direct visualization of leukocyte recruitment in the microvascular bed on a high level of image quality. We here promote the digital intravital epifluorescence microscopy of the postcapillary venule in the cremasteric microcirculation of the rat as a convenient method to qualitatively and quantitatively analyze leukocyte recruitment for IRI-research in striated muscle tissue and provide a detailed manual for accomplishing the technique. We further illustrate common pitfalls and

  13. Multi-wavelength Spectral Analysis of Ellerman Bombs Observed by FISS and IRIS

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jie; Ding, M. D. [School of Astronomy and Space Science, Nanjing University, Nanjing 210023 (China); Cao, Wenda, E-mail: dmd@nju.edu.cn [Big Bear Solar Observatory, New Jersey Institute of Technology, 40386 North Shore Lane, Big Bear City, CA 92314-9672 (United States)

    2017-04-01

    Ellerman bombs (EBs) are a kind of solar activity that is suggested to occur in the lower solar atmosphere. Recent observations using the Interface Region Imaging Spectrograph (IRIS) show connections between EBs and IRIS bombs (IBs), which imply that EBs might be heated to a much higher temperature (8 × 10{sup 4} K) than previous results. Here we perform a spectral analysis of EBs simultaneously observed by the Fast Imaging Solar Spectrograph and IRIS. The observational results show clear evidence of heating in the lower atmosphere, indicated by the wing enhancement in H α , Ca ii 8542 Å, and Mg ii triplet lines and also by brightenings in images of the 1700 Å and 2832 Å ultraviolet continuum channels. Additionally, the intensity of the Mg ii triplet line is correlated with that of H α when an EB occurs, suggesting the possibility of using the triplet as an alternative way to identify EBs. However, we do not find any signal in IRIS hotter lines (C ii and Si iv). For further analysis, we employ a two-cloud model to fit the two chromospheric lines (H α and Ca ii 8542 Å) simultaneously, and obtain a temperature enhancement of 2300 K for a strong EB. This temperature is among the highest of previous modeling results, albeit still insufficient to produce IB signatures at ultraviolet wavelengths.

  14. Analisa Pengaruh Corporate Social Responsibility Terhadap Brand Image Dan Customer Loyalty Di Pop! Hotels Indonesia

    OpenAIRE

    Livia, Astrid; Gladys, Gladys

    2017-01-01

    Penelitian ini dilakukan untuk menganalisa pengaruh CSR terhadap brand image dan customer loyalty pada Pop! Hotels di Indonesia. Penelitian ini menggunakan pendekatan kuantitatif kausal dengan bantuan penyebaran kuesioner yang dibagikan kepada 200 responden yang pernah menginap di Pop! Hotels di Indonesia. Hasil penelitian menunjukkan bahwa CSR berpengaruh positif dan signifikan terhadap brand image dan customer loyalty. Selain itu CSR juga berpengaruh secara tidak langsung terhadap customer ...

  15. Iris recognition using the JAVAVis Library

    Directory of Open Access Journals (Sweden)

    L.Martin García

    2008-12-01

    Full Text Available This project has been created to develop a biometric identification system through a man’s iris using a computer to perform the processing of the pictures. To develop this application, and to differentiate the project from others who have already implemented, we have used the image processing library JAVAVis and JAVA as a programming language.

  16. Primary iris leiomyoma.

    Science.gov (United States)

    Yeaney, Gabrielle A; Platt, Sean; Singh, Arun D

    Intraocular leiomyomas are uncommon and usually occur in the ciliary body. Primary leiomyoma of the iris is both rare and a difficult diagnosis to make, given melanocytic tumors are more common and may be amelanotic. The somewhat controversial diagnosis of iris leiomyoma requires further confirmation by immunohistochemistry and electron microscopy. Herein, we describe a 58-year-old man with a 2-mm round translucent pink lesion of the iris. The tumor was excised by sector iridectomy. Immunohistochemistry showed positivity for both smooth muscle actin and desmin and negativity for S-100, HMB45, SOX10, MelanA, CD31, CD34, and h-caldesmon. Epstein-Barr virus-associated smooth muscle tumor was excluded by chromogenic in situ hybridization-Epstein-Barr virus-encoded RNA. Ultrastructural analysis showed cytoplasmic myofilaments with focal fusiform densities and micropinocytotic vesicles. Our review of previous literature confirmed the unusual nature of this tumor. Primary iris leiomyoma should be considered in the differential of an amelanotic S-100-immunonegative iris tumor. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. 77 FR 31869 - Iris Lacustris (Dwarf Lake Iris); Draft Recovery Plan for Review and Comment

    Science.gov (United States)

    2012-05-30

    ...-FF03E00000] Iris Lacustris (Dwarf Lake Iris); Draft Recovery Plan for Review and Comment AGENCY: Fish and... Service (Service) announces availability for public review of the draft recovery plan for the Iris lacustris (dwarf lake iris), a species that is federally listed as threatened under the Endangered Species...

  18. Peripheral laser iridoplasty opens angle in plateau iris by thinning the cross-sectional tissues

    Directory of Open Access Journals (Sweden)

    Liu J

    2013-09-01

    Full Text Available Ji Liu,1,2 Tania Lamba,1 David A Belyea1 1Department of Ophthalmology, The George Washington University, Washington DC, USA; 2Yale Eye Center, Yale University, New Haven, CT, USA Abstract: Plateau iris syndrome has been described as persistent angle narrowing or occlusion with intraocular pressure elevation after peripheral iridotomy due to the abnormal plateau iris configuration. Argon laser peripheral iridoplasty (ALPI is an effective adjunct procedure to treat plateau iris syndrome. Classic theory suggests that the laser causes the contraction of the far peripheral iris stroma, "pulls" the iris away from the angle, and relieves the iris-angle apposition. We report a case of plateau iris syndrome that was successfully treated with ALPI. Spectral domain optical coherence tomography confirmed the angle was open at areas with laser treatment but remained appositionally closed at untreated areas. Further analysis suggested significant cross-sectional thinning of the iris at laser-treated areas in comparison with untreated areas. The findings indicate that APLI opens the angle, not only by contracting the iris stroma, but also by thinning the iris tissue at the crowded angle. This is consistent with the ALPI technique to aim at the iris as far peripheral as possible. This case also suggests that spectral domain optical coherence tomography is a useful adjunct imaging tool to gonioscopy in assessing the angle condition. Keywords: plateau iris, optic coherence tomography, argon laser peripheral iridoplasty, angle-closure glaucoma

  19. Iris metastasis of gastric adenocarcinoma.

    Science.gov (United States)

    Celebi, Ali Riza Cenk; Kilavuzoglu, Ayse Ebru; Altiparmak, U Emrah; Cosar, C Banu; Ozkiris, Abdullah

    2016-03-08

    Iris metastasis in patients with gastric cancer is extremely rare. Herein, it is aimed to report on a patient with gastric adenocarcinoma and iris metastasis. A 65-year-old patient with the history of gastric cancer was admitted for eye pain and eye redness on his left eye. There was ciliary injection, severe +4 cells with hypopyon in the anterior chamber and a solitary, friable, yellow-white, fleshy-creamy vascularized 2 mm × 4 mm mass on the upper nasal part of the iris within the left eye. The presented patient's mass lesion in the iris fulfilled the criteria of the metastatic iris lesion's appearance. The ocular metastasis occurred during chemotherapy. Iris metastasis can masquerade as iridocyclitis with pseudohypopyon or glaucoma. In patients with a history of gastric cancer that present with an iris mass, uveitis, and high intraocular pressure, ocular metastasis of gastric cancer should be a consideration.

  20. PLATEAU IRIS--DIAGNOSIS AND TREATMENT.

    Science.gov (United States)

    Stefan, Cornel; Iliescu, Daniela Adriana; Batras, Mehdi; Timaru, Cristina Mihaela; De Simone, Algerino

    2015-01-01

    The objective of our study was to review the current knowledge on the diagnosis and treatment options of plateau iris configuration and syndrome. Relevant publications on plateau iris that were published until 2014. Plateau iris syndrome is a form of primary angle closure glaucoma caused by a large or anteriorly positioned ciliary body that leads to mechanical obstruction of trabecular meshwork. This condition is most often found in younger patients. Plateau iris has been considered an abnormal anatomic variant of the iris that can be diagnosed on ultrasound biomicroscopy or optical coherence tomography of anterior segment. Patients with plateau iris syndrome can be recognized by the lack of response in angle opening after iridotomy. The treatment of choice in these cases is argon laser peripheral iridoplasty.

  1. The IRIS user guide

    International Nuclear Information System (INIS)

    Adams, M.; Howells, W.; Telling, M.

    2001-01-01

    The principles of operation of the IRIS instrument based on inelastic neutron scattering and diffraction are described. The procedure of an experiment performance on IRIS consists of selecting sample cans, loading the sample into the neutron beam. Instructions for using the beam line shutter interlock system, IRIS computing procedure, suitable instrument settings and chopper control are included

  2. Relationship of the Van Herick Grading System with Peripheral Iris Configuration and Level of Iris Insertion.

    Science.gov (United States)

    Khan, Faisal Aziz; Niazi, Shafaq Pervez Khan; Khan, Assad Zaman

    2017-09-01

    To determine the relationship of the van Herick angle grading system with the level of iris insertion and peripheral iris configuration. Observational study. Eye department, Combined Military Hospital, Malir Cantt., Karachi, from May to October 2015. Sixty-five eyes of 65 patients were recruited. Anterior chamber depth at the temporal limbus was measured as a fraction of corneal section thickness using van Herick technique and graded on the standard 4-point scale of the van Herick grading system. Gonioscopy of the temporal quadrant was performed with a Posner 4 mirror goniolens and both the true level of iris insertion and peripheral iris configuration were recorded on a 4-point scale so as to equate with the van Herick 4-point grading system. Spearman's rho test was applied to determine the relationship of the van Herick grading system with level of iris root insertion and peripheral iris configuration. Amoderate positive correlation between van Herick grade and peripheral iris configuration was found which was statistically significant (rs=0.42, p < 0.001). Astatistically significant and moderate positive correlation was also detected between van Herick grade and the level of iris insertion (rs=0.45, p < 0.001). The van Herick grade has a moderately positive relationship with the peripheral iris configuration and true level of iris insertion.

  3. The IRIS user-guide

    International Nuclear Information System (INIS)

    Adams, M.A.

    1997-10-01

    This is the first version of the IRIS User-Guide. IRIS is continually evolving and improving and so some of the information contained within this manual will become out of date quite quickly. The basics behind the operation of IRIS, however, should remain essentially constant for the foreseeable future. Updated manuals will be produced when appropriate although it should always be remembered that the most up-to-date sources of information concerning IRIS are the instrument scientist and the local contacts for the experiments. It would be appreciated, however, if this user-guide were to be the first point of call. (author)

  4. Service Quality and the Mediating Effect of Corporate Image on the Relationship between Customer Satisfaction and Customer Loyalty in the Malaysian Hotel Industry

    Directory of Open Access Journals (Sweden)

    Boon-Liat Cheng

    2014-06-01

    Full Text Available Service quality is vital to the success of  any service organization. The rapid growth of the Malaysian hotel industry in the 2000’s forced hotel operators to seriously recognize the importance of service improvement in order to gain competitive advantage. This study aims to examine the impact of service quality on customer satisfaction, and how customer satisfaction subsequently affects customer loyalty in the hotel industry in Malaysia. This study also investigates the mediating effect of corporate image  on the  relationship between customer satisfaction and customer loyalty.  A systematic  sampling approach was adopted  to collect data through self-administered questionnaires from 500 hotel guests. Preliminary data analysis, descriptive analysis, reliability test and regression analysis were adopted to ana-lyze  the  reliability  of  items and the  hypothesized  relationships  in the  proposed  research model.  The findings revealed that perception of service quality is significantly related to customer satisfaction, which in turn generates positive customer loyalty in the hotel industry. Besides, corporate image is found to be a partial mediator in the relationship between customer satisfaction and customer loyalty. Overall, the find-ings of this study would help hotel operators to formulate and implement effective marketing manage-ment strategies to cope with the keen competition in the hotel service industry.

  5. Iris features-based heart disease diagnosis by computer vision

    Science.gov (United States)

    Nguchu, Benedictor A.; Li, Li

    2017-07-01

    The study takes advantage of several new breakthroughs in computer vision technology to develop a new mid-irisbiomedical platform that processes iris image for early detection of heart-disease. Guaranteeing early detection of heart disease provides a possibility of having non-surgical treatment as suggested by biomedical researchers and associated institutions. However, our observation discovered that, a clinical practicable solution which could be both sensible and specific for early detection is still lacking. Due to this, the rate of majority vulnerable to death is highly increasing. The delayed diagnostic procedures, inefficiency, and complications of available methods are the other reasons for this catastrophe. Therefore, this research proposes the novel IFB (Iris Features Based) method for diagnosis of premature, and early stage heart disease. The method incorporates computer vision and iridology to obtain a robust, non-contact, nonradioactive, and cost-effective diagnostic tool. The method analyzes abnormal inherent weakness in tissues, change in color and patterns, of a specific region of iris that responds to impulses of heart organ as per Bernard Jensen-iris Chart. The changes in iris infer the presence of degenerative abnormalities in heart organ. These changes are precisely detected and analyzed by IFB method that includes, tensor-based-gradient(TBG), multi orientations gabor filters(GF), textural oriented features(TOF), and speed-up robust features(SURF). Kernel and Multi class oriented support vector machines classifiers are used for classifying normal and pathological iris features. Experimental results demonstrated that the proposed method, not only has better diagnostic performance, but also provides an insight for early detection of other diseases.

  6. Extending the Capture Volume of an Iris Recognition System Using Wavefront Coding and Super-Resolution.

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Tien, Chung-Hao; Chang, Chin-Chen

    2016-12-01

    Iris recognition has gained increasing popularity over the last few decades; however, the stand-off distance in a conventional iris recognition system is too short, which limits its application. In this paper, we propose a novel hardware-software hybrid method to increase the stand-off distance in an iris recognition system. When designing the system hardware, we use an optimized wavefront coding technique to extend the depth of field. To compensate for the blurring of the image caused by wavefront coding, on the software side, the proposed system uses a local patch-based super-resolution method to restore the blurred image to its clear version. The collaborative effect of the new hardware design and software post-processing showed great potential in our experiment. The experimental results showed that such improvement cannot be achieved by using a hardware-or software-only design. The proposed system can increase the capture volume of a conventional iris recognition system by three times and maintain the system's high recognition rate.

  7. The infrared imaging spectrograph (IRIS) for TMT: volume phase holographic grating performance testing and discussion

    Science.gov (United States)

    Chen, Shaojie; Meyer, Elliot; Wright, Shelley A.; Moore, Anna M.; Larkin, James E.; Maire, Jerome; Mieda, Etsuko; Simard, Luc

    2014-07-01

    Maximizing the grating efficiency is a key goal for the first light instrument IRIS (Infrared Imaging Spectrograph) currently being designed to sample the diffraction limit of the TMT (Thirty Meter Telescope). Volume Phase Holographic (VPH) gratings have been shown to offer extremely high efficiencies that approach 100% for high line frequencies (i.e., 600 to 6000l/mm), which has been applicable for astronomical optical spectrographs. However, VPH gratings have been less exploited in the near-infrared, particularly for gratings that have lower line frequencies. Given their potential to offer high throughputs and low scattered light, VPH gratings are being explored for IRIS as a potential dispersing element in the spectrograph. Our team has procured near-infrared gratings from two separate vendors. We have two gratings with the specifications needed for IRIS current design: 1.51-1.82μm (H-band) to produce a spectral resolution of 4000 and 1.19-1.37μm (J-band) to produce a spectral resolution of 8000. The center wavelengths for each grating are 1.629μm and 1.27μm, and the groove densities are 177l/mm and 440l/mm for H-band R=4000 and J-band R=8000, respectively. We directly measure the efficiencies in the lab and find that the peak efficiencies of these two types of gratings are quite good with a peak efficiency of ~88% at the Bragg angle in both TM and TE modes at H-band, and 90.23% in TM mode, 79.91% in TE mode at J-band for the best vendor. We determine the drop in efficiency off the Bragg angle, with a 20-23% decrease in efficiency at H-band when 2.5° deviation from the Bragg angle, and 25%-28% decrease at J-band when 5° deviation from the Bragg angle.

  8. Integrated risk information system (IRIS)

    Energy Technology Data Exchange (ETDEWEB)

    Tuxen, L. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The Integrated Risk Information System (IRIS) is an electronic information system developed by the US Environmental Protection Agency (EPA) containing information related to health risk assessment. IRIS is the Agency`s primary vehicle for communication of chronic health hazard information that represents Agency consensus following comprehensive review by intra-Agency work groups. The original purpose for developing IRIS was to provide guidance to EPA personnel in making risk management decisions. This original purpose for developing IRIS was to guidance to EPA personnel in making risk management decisions. This role has expanded and evolved with wider access and use of the system. IRIS contains chemical-specific information in summary format for approximately 500 chemicals. IRIS is available to the general public on the National Library of Medicine`s Toxicology Data Network (TOXNET) and on diskettes through the National Technical Information Service (NTIS).

  9. Evaluation of Genetic Diversity of Iris Genotypes (Iris spp Using ISSR

    Directory of Open Access Journals (Sweden)

    seyedeh zeinab attari

    2017-02-01

    Full Text Available Introduction: Some of Iris species are growing in different parts of the Iran as wild species. Iris species have important medicinal and horticultural properties. Understanding of the genetic variation within and between populations is essential for the establishment of effective and efficient methods for conservation of the plants. Genetic variation studies are fundamental for the management and conservation of this species. The use of molecular markers is a powerful tool in the genetic study of populations. The use of DNA marker, such as AFLP, SSR, RAPD and ISSR represents an alternative method in detection of polymorphism. ISSRs are highly variable, require less investment in time, money and labor than other methods. ISSR can generate higher percentages of polymorphic loci than other PCR methods. These can serve as an efficient tool for phylogenetic studies. ISSRs had reported that used in studies of cultivated species to produce genetic linkage maps and to determine the relatedness of lines of agriculturally important species. ISSR analysis involves the PCR amplification of regions between adjacent, inversely oriented microsatellites, using a single simple sequence repeat (SSR motifs (dinucleotide, trinucleotide, tetranucleotide or penta nucleotides. Therefore, little is known about the genetic variability of the Iranian Iris ssp .The objectives of this study were to evaluate genetic diversity among genotypes using ISSR markers and the degree of polymorphism generated from ISSR technique as a pre-requisite for their applicability to population genetics studies in Iris ssp. Materials and Methods: To evaluate genetic variations in some wild Iris genotypes, Iris kopetdaghensis ،Iris songarica and Iris fosteriana were collected from some parts of Khorasan province. Genomic DNA was extracted from young leaves following the cetyltrimethylammonium bromide (CTAB procedure. Extracted DNA concentration was quantified by using the spectrophotometer

  10. Using crypts as iris minutiae

    Science.gov (United States)

    Shen, Feng; Flynn, Patrick J.

    2013-05-01

    Iris recognition is one of the most reliable biometric technologies for identity recognition and verification, but it has not been used in a forensic context because the representation and matching of iris features are not straightforward for traditional iris recognition techniques. In this paper we concentrate on the iris crypt as a visible feature used to represent the characteristics of irises in a similar way to fingerprint minutiae. The matching of crypts is based on their appearances and locations. The number of matching crypt pairs found between two irises can be used for identity verification and the convenience of manual inspection makes iris crypts a potential candidate for forensic applications.

  11. Efficient iris texture analysis method based on Gabor ordinal measures

    Science.gov (United States)

    Tajouri, Imen; Aydi, Walid; Ghorbel, Ahmed; Masmoudi, Nouri

    2017-07-01

    With the remarkably increasing interest directed to the security dimension, the iris recognition process is considered to stand as one of the most versatile technique critically useful for the biometric identification and authentication process. This is mainly due to every individual's unique iris texture. A modestly conceived efficient approach relevant to the feature extraction process is proposed. In the first place, iris zigzag "collarette" is extracted from the rest of the image by means of the circular Hough transform, as it includes the most significant regions lying in the iris texture. In the second place, the linear Hough transform is used for the eyelids' detection purpose while the median filter is applied for the eyelashes' removal. Then, a special technique combining the richness of Gabor features and the compactness of ordinal measures is implemented for the feature extraction process, so that a discriminative feature representation for every individual can be achieved. Subsequently, the modified Hamming distance is used for the matching process. Indeed, the advanced procedure turns out to be reliable, as compared to some of the state-of-the-art approaches, with a recognition rate of 99.98%, 98.12%, and 95.02% on CASIAV1.0, CASIAV3.0, and IIT Delhi V1 iris databases, respectively.

  12. TAPIOCA MELANOMA OF THE IRIS

    NARCIS (Netherlands)

    DEKEIZER, RJW; OOSTERHUIS, JA; HOUTMAN, WA; DEWOLFFROUENDAAL, D

    Clinical identification of tapioca melanoma of the iris is important because its medical treatment may differ from that of other malignant iris melanomas. The characteristic iris nodules must be differentiated from granulomatous uveitis, metastases, and Lisch nodules (neurofibromatosis). We will

  13. Appropriate Objective Functions for Quantifying Iris Mechanical Properties Using Inverse Finite Element Modeling.

    Science.gov (United States)

    Pant, Anup D; Dorairaj, Syril K; Amini, Rouzbeh

    2018-07-01

    Quantifying the mechanical properties of the iris is important, as it provides insight into the pathophysiology of glaucoma. Recent ex vivo studies have shown that the mechanical properties of the iris are different in glaucomatous eyes as compared to normal ones. Notwithstanding the importance of the ex vivo studies, such measurements are severely limited for diagnosis and preclude development of treatment strategies. With the advent of detailed imaging modalities, it is possible to determine the in vivo mechanical properties using inverse finite element (FE) modeling. An inverse modeling approach requires an appropriate objective function for reliable estimation of parameters. In the case of the iris, numerous measurements such as iris chord length (CL) and iris concavity (CV) are made routinely in clinical practice. In this study, we have evaluated five different objective functions chosen based on the iris biometrics (in the presence and absence of clinical measurement errors) to determine the appropriate criterion for inverse modeling. Our results showed that in the absence of experimental measurement error, a combination of iris CL and CV can be used as the objective function. However, with the addition of measurement errors, the objective functions that employ a large number of local displacement values provide more reliable outcomes.

  14. Iridium Interfacial Stack (IRIS)

    Science.gov (United States)

    Spry, David James (Inventor)

    2015-01-01

    An iridium interfacial stack ("IrIS") and a method for producing the same are provided. The IrIS may include ordered layers of TaSi.sub.2, platinum, iridium, and platinum, and may be placed on top of a titanium layer and a silicon carbide layer. The IrIS may prevent, reduce, or mitigate against diffusion of elements such as oxygen, platinum, and gold through at least some of its layers.

  15. Deep learning architecture for iris recognition based on optimal Gabor filters and deep belief network

    Science.gov (United States)

    He, Fei; Han, Ye; Wang, Han; Ji, Jinchao; Liu, Yuanning; Ma, Zhiqiang

    2017-03-01

    Gabor filters are widely utilized to detect iris texture information in several state-of-the-art iris recognition systems. However, the proper Gabor kernels and the generative pattern of iris Gabor features need to be predetermined in application. The traditional empirical Gabor filters and shallow iris encoding ways are incapable of dealing with such complex variations in iris imaging including illumination, aging, deformation, and device variations. Thereby, an adaptive Gabor filter selection strategy and deep learning architecture are presented. We first employ particle swarm optimization approach and its binary version to define a set of data-driven Gabor kernels for fitting the most informative filtering bands, and then capture complex pattern from the optimal Gabor filtered coefficients by a trained deep belief network. A succession of comparative experiments validate that our optimal Gabor filters may produce more distinctive Gabor coefficients and our iris deep representations be more robust and stable than traditional iris Gabor codes. Furthermore, the depth and scales of the deep learning architecture are also discussed.

  16. THE INFLUENCE OF PRODUCT QUALITY , PRICE PERCEPTION AND BRAND IMAGE ON SATISFACTION AND CUSTOMER LOYALTY HOLCIM CONCRETE READYMIX IN JAKARTA

    Directory of Open Access Journals (Sweden)

    Sita Budiastari

    2016-09-01

    Full Text Available The purpose of this research is to find a picture of the effect of product quality , price perception and brand image on satisfaction and customer loyalty ready mix concrete in Jakarta . This research is a quantitative study with descriptive and causal methods undertaken at Holcim Beton in 2013 with a sample of 100 customers in Jakarta and its surrounding the industrial and commercial segments project . Data collection by questionnaire respondents and analyzed using path analysis with SPSS version 20.0. The results of the study concluded that ( 1 product quality does not effect to customer satisfaction ( 2 Perception price positive and significant effect on customer satisfaction, ( 3 Brand Image does not have an influence on customer satisfaction, ( 4 all independent variables , quality of products , Perception price and a positive brand image and significant consequences for the dependent variable Customer satisfaction, with the value of determination of 50%, while 50% are influenced by other variables ( 5 Product Quality and significant effect on customer loyalty through customer satisfaction, ( 6 Perceived Price does not effect on loyalty through customer satisfaction, ( 7 brand image have effect and siginikan loyalty through customer satisfaction, ( 8 Dependent variable of product quality , price perception and brand image together and significant effect on customer loyalty through customer satisfaction, with value of determination of 77.4 %, and 22.6 % are influenced by other factors. The findings recommend that Holcim aims to improve product quality , perceived price and brand image to increase loyalty through customer satisfaction . It is also recommended to Holcim for increase of services and information to customers in order for increase customer satisfaction and loyalty.

  17. Engineering a Light-Attenuating Artificial Iris

    Science.gov (United States)

    Shareef, Farah J.; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-01-01

    Purpose Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. Methods The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Results Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Conclusions Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage. PMID:27116547

  18. Engineering a Light-Attenuating Artificial Iris.

    Science.gov (United States)

    Shareef, Farah J; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-04-01

    Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage.

  19. Analisa Pengaruh Brand Image Terhadap Customer Loyalty Dengan Customer Satisfaction Sebagai Mediator Pada the Dreamland Luxury Villas and Spa, Bali.

    OpenAIRE

    Leliga, Felicia Juliani

    2013-01-01

    Penelitian ini dilakukan untuk mengetahui customer loyalty pada brand The Dreamland Luxury Villas and Spa, Bali melalui penilaian responden terhadap dimensi brand image yang terdiri dari brand strength, brand favorability, dan brand uniqueness, dengan menggunakan customer satisfaction sebagai variabel mediator. Dalam penelitian ini, penulis menggunakan metode kuantitatif dengan teknik partial least square (PLS). Dari hasil analisa, disimpulkan bahwa tidak ada pengaruh brand strength dan brand...

  20. Image Quality Assessment for Fake Biometric Detection: Application to Iris, Fingerprint, and Face Recognition.

    Science.gov (United States)

    Galbally, Javier; Marcel, Sébastien; Fierrez, Julian

    2014-02-01

    To ensure the actual presence of a real legitimate trait in contrast to a fake self-manufactured synthetic or reconstructed sample is a significant problem in biometric authentication, which requires the development of new and efficient protection measures. In this paper, we present a novel software-based fake detection method that can be used in multiple biometric systems to detect different types of fraudulent access attempts. The objective of the proposed system is to enhance the security of biometric recognition frameworks, by adding liveness assessment in a fast, user-friendly, and non-intrusive manner, through the use of image quality assessment. The proposed approach presents a very low degree of complexity, which makes it suitable for real-time applications, using 25 general image quality features extracted from one image (i.e., the same acquired for authentication purposes) to distinguish between legitimate and impostor samples. The experimental results, obtained on publicly available data sets of fingerprint, iris, and 2D face, show that the proposed method is highly competitive compared with other state-of-the-art approaches and that the analysis of the general image quality of real biometric samples reveals highly valuable information that may be very efficiently used to discriminate them from fake traits.

  1. Porcine cadaver iris model for iris heating during corneal surgery with a femtosecond laser

    Science.gov (United States)

    Sun, Hui; Fan, Zhongwei; Wang, Jiang; Yan, Ying; Juhasz, Tibor; Kurtz, Ron

    2015-03-01

    Multiple femtosecond lasers have now been cleared for use for ophthalmic surgery, including for creation of corneal flaps in LASIK surgery. Preliminary study indicated that during typical surgical use, laser energy may pass beyond the cornea with potential effects on the iris. As a model for laser exposure of the iris during femtosecond corneal surgery, we simulated the temperature rise in porcine cadaver iris during direct illumination by the femtosecond laser. Additionally, ex-vivo iris heating due to femtosecond laser irradiation was measured with an infrared thermal camera (Fluke corp. Everett, WA) as a validation of the simulation.

  2. Iris Template Protection Based on Local Ranking

    Directory of Open Access Journals (Sweden)

    Dongdong Zhao

    2018-01-01

    Full Text Available Biometrics have been widely studied in recent years, and they are increasingly employed in real-world applications. Meanwhile, a number of potential threats to the privacy of biometric data arise. Iris template protection demands that the privacy of iris data should be protected when performing iris recognition. According to the international standard ISO/IEC 24745, iris template protection should satisfy the irreversibility, revocability, and unlinkability. However, existing works about iris template protection demonstrate that it is difficult to satisfy the three privacy requirements simultaneously while supporting effective iris recognition. In this paper, we propose an iris template protection method based on local ranking. Specifically, the iris data are first XORed (Exclusive OR operation with an application-specific string; next, we divide the results into blocks and then partition the blocks into groups. The blocks in each group are ranked according to their decimal values, and original blocks are transformed to their rank values for storage. We also extend the basic method to support the shifting strategy and masking strategy, which are two important strategies for iris recognition. We demonstrate that the proposed method satisfies the irreversibility, revocability, and unlinkability. Experimental results on typical iris datasets (i.e., CASIA-IrisV3-Interval, CASIA-IrisV4-Lamp, UBIRIS-V1-S1, and MMU-V1 show that the proposed method could maintain the recognition performance while protecting the privacy of iris data.

  3. Analisis Pengaruh Brand Image, Price Perception, Dan Service Quality Terhadap Customer Loyalty Pada Pelanggan Urban Kitchen

    OpenAIRE

    Joshua, Timothy Joshua; Haryadi, Eddy

    2014-01-01

    This study was conducted to determine the influence of Brand Image, Price Perception, and Customer Service Qualityon Customer Loyalty in Urban Kitchen. The questionnaires were distributed to 150 respondents in four locations of Urban Kitchen employing simple random sampling technique. The data obtained were processed and analyzed using the Structural Equation Model (SEM) with LISREL8.72. The results indicate that Brand Image and Service Quality have significant influences on Customer Loyalty,...

  4. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis.

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Wang, Wei; Tien, Chung-Hao

    2018-03-06

    In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL) pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR) was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme.

  5. Influence of Customer Focused Mission Statement on Customer Satisfaction

    Directory of Open Access Journals (Sweden)

    Chijioke Nwachukwu

    2017-01-01

    Full Text Available The purpose of this study is to examine the influence of customer‑focused mission statements on customer satisfaction in selected cell phone manufacturing companies in the United States. The study employed content analysis for the mission statement and data from America customer satisfaction index (ACSI. In analysing our data, Pearson correlation, and multiple regression techniques were used. The result showed that product and service, technology, philosophy, self‑concept, and public image mission statement components are strongly positively correlated with customer satisfaction. Customer, survival, growth and profitability and market mission statement components are insignificantly negatively correlated with customer satisfaction. The study, therefore, recommends that companies that want to remain competitive by enhancing customer satisfaction should formulate mission statements from a customer perspective so that they include product and service, technology, philosophy, self‑concept, and public image components. The main limitation of the study represents the sample size and structure. This study empirically investigated the correlation and association of nine mission statement components with customer satisfaction.

  6. Restoration of an atrophic eye socket with custom made eye prosthesis, utilizing digital photography

    Directory of Open Access Journals (Sweden)

    Gaurav P Jayaswal

    2011-01-01

    Full Text Available Ocular defects may cause several ocular and orbital disorders, which require surgical intervention. These defects are psychologically disturbing for the patients, and therefore, they require immediate management and rehabilitation by a team of specialist. Ocular prosthesis may be either readymade (stock or custom made. Fabrication of a custom ocular prosthesis allows for a range of variations during construction. The iris can also be custom made by ocular painting or by digital photography. The optimum cosmetic and functional results of a custom-made prosthesis enhance the patient′s rehabilitation to a normal life style. This paper elaborates the technique for fabrication of a custom-made ocular prosthesis for an atrophic eye socket utilizing digital photography.

  7. MULTI-WAVELENGTH STUDY OF TRANSITION REGION PENUMBRAL SUBARCSECOND BRIGHT DOTS USING IRIS AND NST

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Na; Liu, Chang; Xu, Yan; Wang, Haimin [Space Weather Research Laboratory, New Jersey Institute of Technology, University Heights, Newark, NJ 07102-1982 (United States); Yurchyshyn, Vasyl [Big Bear Solar Observatory, New Jersey Institute of Technology, 40386 North Shore Lane, Big Bear City, CA 92314-9672 (United States); Tian, Hui [School of Earth and Space Sciences, Peking University, Beijing, 100871 (China); Kleint, Lucia, E-mail: na.deng@njit.edu [University of Applied Sciences and Arts Northwestern Switzerland, Bahnhofstr. 6, 5210 Windisch (Switzerland)

    2016-10-01

    Using high-resolution transition region (TR) observations taken by the Interface Region Imaging Spectrograph ( IRIS ) mission, Tian et al. revealed numerous short-lived subarcsecond bright dots (BDs) above sunspots (mostly located in the penumbrae), which indicate yet unexplained small-scale energy releases. Moreover, whether or not these subarcsecond TR brightenings have any signature in the lower atmosphere and how they are formed are still not fully resolved. This paper presents a multi-wavelength study of the TR penumbral BDs using a coordinated observation of a near disk center sunspot with IRIS and the 1.6 m New Solar Telescope (NST) at the Big Bear Solar Observatory. NST provides high-resolution chromospheric and photospheric observations with narrowband H α imaging spectroscopy and broadband TiO images, respectively, complementary to IRIS TR observations. A total of 2692 TR penumbral BDs are identified from a 37 minute time series of IRIS 1400 Å slit-jaw images. Their locations tend to be associated more with downflowing and darker fibrils in the chromosphere, and weakly associated with bright penumbral features in the photosphere. However, temporal evolution analyses of the BDs show that there is no consistent and convincing brightening response in the chromosphere. These results are compatible with a formation mechanism of the TR penumbral BDs by falling plasma from coronal heights along more vertical and dense magnetic loops. The BDs may also be produced by small-scale impulsive magnetic reconnection taking place sufficiently high in the atmosphere that has no energy release in the chromosphere.

  8. PLATEAU IRIS – DIAGNOSIS AND TREATMENT

    Science.gov (United States)

    Stefan, Cornel; Iliescu, Daniela Adriana; Batras, Mehdi; Timaru, Cristina Mihaela; De Simone, Algerino

    2015-01-01

    Objectives: The objective of our study was to review the current knowledge on the diagnosis and treatment options of plateau iris configuration and syndrome. Systematic review methodology: Relevant publications on plateau iris that were published until 2014. Conclusions: Plateau iris syndrome is a form of primary angle closure glaucoma caused by a large or anteriorly positioned ciliary body that leads to mechanical obstruction of trabecular meshwork. This condition is most often found in younger patients. Plateau iris has been considered an abnormal anatomic variant of the iris that can be diagnosed on ultrasound biomicroscopy or optical coherence tomography of anterior segment. Patients with plateau iris syndrome can be recognized by the lack of response in angle opening after iridotomy. The treatment of choice in these cases is argon laser peripheral iridoplasty PMID:27373109

  9. Does iris change over time?

    Science.gov (United States)

    Mehrotra, Hunny; Vatsa, Mayank; Singh, Richa; Majhi, Banshidhar

    2013-01-01

    Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008-2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs.

  10. The Effect of Store Brand Image and Service Quality Towards Customer Loyalty at Freshmart Superstore Manado

    OpenAIRE

    Tumiwa, Johan; Lapian, S. L. H. V. Joyce; Kumowal, Rivo Christian

    2016-01-01

    Customer loyalty has been recognized as the dominant factor in a superstore€™s success. The customer loyalty subject has become of increased interest to most superstore in the competitive situation over the last few years. Store brand image and service quality describes what customers are looking for that is likely to be advantageous to the Superstore. The objectives of this research are to analyze the effect of store brand image, and service quality towards consumer loyalty, simultaneously a...

  11. Ways of radical change of the image of tax and customs officers

    Directory of Open Access Journals (Sweden)

    Arutiunian V. L.

    2018-03-01

    Full Text Available the article discusses the problem concerning some changes in image of tax and customs officers. Tax and customs system is a multifunctional structure, therefore, in order to ensure unified application of the legislation, professional training of staff should be organized by means of guidelines, workshop discussions, qualification trainings and other instruments, which should be attended by the employees of territorial and regional tax and customs authorities. Along with implementation of legislative reforms and application of advanced technologies for increase of confidence in tax system and expansion of capabilities, the role of a professional tax officer is of high importance.

  12. IRIS Burst Spectra Co-spatial to a Quiet-Sun Ellerman-like Brightening

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, C. J.; Erdélyi, R. [Solar Physics and Space Plasma Research Centre, University of Sheffield, Hicks Building, Hounsfield Road, Sheffield, S3 7RH (United Kingdom); Freij, N.; Oliver, R. [Departament de Física, Universitat de les Illes Balears, E-07122 Palma de Mallorca (Spain); Reid, A.; Mathioudakis, M., E-mail: c.j.nelson@sheffield.ac.uk [Astrophysics Research Centre (ARC), School of Mathematics and Physics, Queens University, Belfast, BT7 1NN (United Kingdom)

    2017-08-10

    Ellerman bombs (EBs) have been widely studied over the past two decades; however, only recently have the counterparts of these events been observed in the quiet-Sun. The aim of this article is to further understand small-scale quiet-Sun Ellerman-like brightenings (QSEBs) through research into their spectral signatures, including investigating whether the hot signatures associated with some EBs are also visible co-spatial to any QSEBs. We combine H α and Ca ii 8542 Å line scans at the solar limb with spectral and imaging data sampled by the Interface Region Imaging Spectrograph ( IRIS ). Twenty-one QSEBs were identified with average lifetimes, lengths, and widths measured to be around 120 s, 0.″63, and 0.″35, respectively. Three of these QSEBs displayed clear repetitive flaring through their lifetimes, comparable to the behavior of EBs in active regions. Two QSEBs in this sample occurred co-spatial to increased emission in SDO /AIA 1600 Å and IRIS slit-jaw imager 1400 Å data; however, these intensity increases were smaller than those reported co-spatially with EBs. One QSEB was also sampled by the IRIS slit during its lifetime, displaying increases in intensity in the Si iv 1393 Å and Si iv 1403 Å cores, as well as the C ii and Mg ii line wings, analogous to IRIS bursts (IBs). Using RADYN simulations, we are unable to reproduce the observed QSEB H α and Ca ii 8542 Å line profiles, leaving the question of the temperature stratification of QSEBs open. Our results imply that some QSEBs could be heated to transition region temperatures, suggesting that IB profiles should be observed throughout the quiet-Sun.

  13. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Wang, Wei; Tien, Chung-Hao

    2018-01-01

    In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL) pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR) was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme. PMID:29509692

  14. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis

    Directory of Open Access Journals (Sweden)

    Sheng-Hsun Hsieh

    2018-03-01

    Full Text Available In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme.

  15. Does Iris Change Over Time?

    Science.gov (United States)

    Mehrotra, Hunny; Vatsa, Mayank; Singh, Richa; Majhi, Banshidhar

    2013-01-01

    Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008–2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs. PMID:24244305

  16. Does iris change over time?

    Directory of Open Access Journals (Sweden)

    Hunny Mehrotra

    Full Text Available Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008-2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs.

  17. Utilizing HyspIRI Prototype Data for Geological Exploration Applications: A Southern California Case Study

    Directory of Open Access Journals (Sweden)

    Wendy M. Calvin

    2016-02-01

    Full Text Available The purpose of this study was to demonstrate the value of the proposed Hyperspectral Infrared Imager (HyspIRI instrument for geological mapping applications. HyspIRI-like data were collected as part of the HyspIRI airborne campaign that covered large regions of California, USA, over multiple seasons. This work focused on a Southern California area, which encompasses Imperial Valley, the Salton Sea, the Orocopia Mountains, the Chocolate Mountains, and a variety of interesting geological phenomena including fumarole fields and sand dunes. We have mapped hydrothermal alteration, lithology and thermal anomalies, demonstrating the value of this type of data for future geologic exploration activities. We believe HyspIRI will be an important instrument for exploration geologists as data may be quickly manipulated and used for remote mapping of hydrothermal alteration minerals, lithology and temperature anomalies.

  18. Face-iris multimodal biometric scheme based on feature level fusion

    Science.gov (United States)

    Huo, Guang; Liu, Yuanning; Zhu, Xiaodong; Dong, Hongxing; He, Fei

    2015-11-01

    Unlike score level fusion, feature level fusion demands all the features extracted from unimodal traits with high distinguishability, as well as homogeneity and compatibility, which is difficult to achieve. Therefore, most multimodal biometric research focuses on score level fusion, whereas few investigate feature level fusion. We propose a face-iris recognition method based on feature level fusion. We build a special two-dimensional-Gabor filter bank to extract local texture features from face and iris images, and then transform them by histogram statistics into an energy-orientation variance histogram feature with lower dimensions and higher distinguishability. Finally, through a fusion-recognition strategy based on principal components analysis and support vector machine (FRSPS), feature level fusion and one-to-n identification are accomplished. The experimental results demonstrate that this method can not only effectively extract face and iris features but also provide higher recognition accuracy. Compared with some state-of-the-art fusion methods, the proposed method has a significant performance advantage.

  19. Iris and periocular biometrics

    CERN Document Server

    Rathgeb, Christian

    2017-01-01

    This book provides an overview of scientific fundamentals and principles of iris and periocular biometric recognition. It covers: an introduction to iris and periocular recognition; a selective overview of issues and challenges; soft biometric classification; security aspects; privacy protection and forensics; and future trends.

  20. Biometric verificaton and biometric identification of a person by methods of statistical analysis of digitized iris images

    Czech Academy of Sciences Publication Activity Database

    Machala, L.; Pospíšil, Jaroslav

    40-41, - (2001), s. 155-162 ISSN 0231-9365 Institutional research plan: CEZ:AV0Z1010921 Keywords : biometric verification * biometric idntification * human eye`s iris * statistical error of type I * statistical erroer II * charasteristic iris vector Subject RIV: BH - Optics, Masers, Lasers

  1. Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation.

    Science.gov (United States)

    Forlini, Cesare; Forlini, Matteo; Rejdak, Robert; Prokopiuk, Agata; Levkina, Oxana; Bratu, Adriana; Rossini, Paolo; Cagampang, Perfecto R; Cavallini, Gian Maria

    2013-03-01

    Combined post-traumatic aniridia and aphakia demand extensive and complex reconstructive surgery. We present our approach for simultaneous correction of this surgical situation with the use of the ArtificialIris (Dr. Schmidt Intraocularlinsen GmbH, Germany) with a foldable acrylic IOL Lentis L-313 (Oculentis, GmbH, Germany) sutured to its surface. The novelty (our first operation was on June 2010) of this surgical technique is based on the combined use of foldable (with closed haptics) IOL and Artificialiris to correct post-traumatic aniridia and aphakia. Four consecutive cases of combined post-traumatic lesions of iris and lens, corrected with complex device ArtificialIris and foldable IOL. In two cases, the compound implant was sutured to the sclera in sulcus during the penetrating keratoplasty; in another case, it was positioned through a corneal incision of about 5.0 mm with transscleral fixation, and in one patient with preserved capsular support and possibility of IOL in-the-bag implantation the ArtificialIris was placed in sulcus sutureless through a clear corneal tunnel. Maximal follow-up was 6 months. The complex device was placed firmly fixed within the sulcus, including in the eye implanted without sutures, and showed a stable and centered position without any tilt or torque. Management of post-traumatic aniridia combined with aphakia by haptic fixation of a foldable acrylic IOL on a foldable iris prosthesis appears to be a promising approach which gives the surgeon the possibility to correct a complex lesion with one procedure, which is less traumatic and faster. Existence of foldable materials, both iris and IOL, permits relatively small corneal incisions (4.0-5.0 mm). Moreover, the custom-tailored iris prosthesis gives a perfect aesthetic result.

  2. What Genes Tell about Iris Appearance

    DEFF Research Database (Denmark)

    Harder, Stine; Christoffersen, Susanne R.; Johansen, Peter

    2012-01-01

    Predicting phenotypes based on genotypes is generally hard, but has shown good results for prediction of iris color. We propose to correlate the appearance of iris with DNA. Six single-nucleotide polymorphisms (SNPs) have previously been shown to correlate with human iris color, and we demonstrat...

  3. Transient analysis of the IRIS reactor

    International Nuclear Information System (INIS)

    Bajs, T.; Oriani, L.; Ricotti, M.E.; Barroso, A.C.

    2002-01-01

    An international consortium of industry, laboratory, university and utility establishments, led by Westinghouse, is developing a modular, integral, light water cooled, small to medium power reactor, the International Reactor Innovative and Secure (IRIS). IRIS features innovative, advanced engineering, but it is firmly based on the proven technology of pressurized water reactors (PWR). Given the large number of organizations involved in the IRIS design, the RELAP5/MOD 3.3 code has been selected as the main system code. A nodalization of the reference IRIS design has been developed with a basic set of protective functions and controls. Engineered Safety Features of the concept are being also implemented, and in particular the Emergency Heat Removal System that is used for safety grade decay heat removal and in the small break LOCA response of IRIS (Large break LOCAs are eliminated in IRIS by the adoption of the Integral layout) This paper discusses developed model and transient behavior of the system for representative transient sequences.(author)

  4. Dom IRIS in njegova vloga v rehabilitaciji: Smart Home IRIS and its role in rehabilitation: Smart Home IRIS and its role in rehabilitation:

    OpenAIRE

    Jenko, Mojca; Ocepek, Julija; Zupan, Anton

    2010-01-01

    Smart Home IRIS is a demonstrative apartment, founded in 2008 on the basis of numerous European smart home projects. The aim of this study was to establish the role of Smart Home IRIS in improving quality of life for persons with disabilities and elderly in Slovenia and the satisfaction of persons who have already been involved in a treatment in it. We analyzed a satisfaction questionnaire of the treatment in Smart Home IRIS, sent to all patients in 2008 (79 in total), as well as the problems...

  5. The radiology of IRIS (immune reconstitution inflammatory syndrome) in patients with mycobacterial tuberculosis and HIV co-infection: appearances in 11 patients

    International Nuclear Information System (INIS)

    Rajeswaran, G.; Becker, J.L.; Michailidis, C.; Pozniak, A.L.; Padley, S.P.G.

    2006-01-01

    Aim: To determine the radiological manifestations of IRIS (immune reconstitution inflammatory syndrome) in patients with HIV and mycobacterium tuberculosis co-infection, in the context of their demographic and clinical data. Materials and methods: The radiological imaging, demographic and clinical data of 11 patients diagnosed with IRIS associated with HIV and mycobacterial tuberculosis co-infection were studied retrospectively. Where available, follow-up imaging studies were also reviewed. Results: The most common radiological feature of IRIS was lymph node enlargement (73%), with central low attenuation centres, in keeping with necrosis, present in most of these cases (88%). Most commonly affected were intra-abdominal nodes (70%), followed by axillary (40%) and mediastinal lymph nodes (36%). Within the lung parenchyma, diffuse, bilateral pulmonary nodules were seen in 55% of cases. Unilateral small volume pleural effusions were seen in two cases with associated parenchymal changes seen in only one. Small volume ascites was seen in two cases. Thirty-six percent of cases presented with new or worsening abscesses despite treatment. In this context, image-guided radiological drainage proved a useful adjunct to the conventional medical therapy for IRIS. The most common clinical signs of IRIS included fever (64%), abdominal pain (36%) and cough (27%). Conclusion: We have described the radiological features that are characteristic in IRIS and the importance of putting these into context with the clinical and pathological findings as part of a multidisciplinary approach in making the diagnosis. The role of the radiologist is central in diagnosis, monitoring of disease progression and management of complications in patients with IRIS

  6. Microdose fluorescence imaging of ABY-029 on an operating microscope adapted by custom illumination and imaging modules

    OpenAIRE

    Elliott, Jonathan T.; Dsouza, Alisha V.; Marra, Kayla; Pogue, Brian W.; Roberts, David W.; Paulsen, Keith D.

    2016-01-01

    Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system spe...

  7. [Intraoperative floppy iris syndrome].

    Science.gov (United States)

    Mazal, Z

    2007-04-01

    In the year 2005, Chang and Cambell described unusual reaction of the iris during the cataract surgery in patients treated with tamsulosine. This was named as IFIS, an acronym for the Intraoperative Floppy Iris Syndrome. In its advanced stage, the syndrome is characterized by insufficient mydfiasis before the surgery, narrowing of the pupil during the surgery, its impossible dilatation during the surgery by means of stretching, unusual elasticity of the pupilar margin, surging and fluttering iris with tendency to prolapse. The same manifestations we observed in our patients and we confirm the direct connection with tamsulosine hydrochloride treatment. Tamsulosine is the antagonist of alpha 1A adrenergic receptors whose are present, except in the smooth musculature of the prostate gland and the urinary bladder, in the iris dilator as well. At the same time we observed this syndrome rarely in some patients not using tamsulosine. In most cases, these patients were treated with antipsychotic drugs.

  8. An Accurate and Efficient User Authentication Mechanism on Smart Glasses Based on Iris Recognition

    Directory of Open Access Journals (Sweden)

    Yung-Hui Li

    2017-01-01

    Full Text Available In modern society, mobile devices (such as smart phones and wearable devices have become indispensable to almost everyone, and people store personal data in devices. Therefore, how to implement user authentication mechanism for private data protection on mobile devices is a very important issue. In this paper, an intelligent iris recognition mechanism is designed to solve the problem of user authentication in wearable smart glasses. Our contributions include hardware and software. On the hardware side, we design a set of internal infrared camera modules, including well-designed infrared light source and lens module, which is able to take clear iris images within 2~5 cm. On the software side, we propose an innovative iris segmentation algorithm which is both efficient and accurate to be used on smart glasses device. Another improvement to the traditional iris recognition is that we propose an intelligent Hamming distance (HD threshold adaptation method which dynamically fine-tunes the HD threshold used for verification according to empirical data collected. Our final system can perform iris recognition with 66 frames per second on a smart glasses platform with 100% accuracy. As far as we know, this system is the world’s first application of iris recognition on smart glasses.

  9. LOCA analysis of the IRIS reactor

    International Nuclear Information System (INIS)

    Bajs, T.; Grgic, D.; Cavlina, N.

    2003-01-01

    The IRIS reactor (International Reactor Innovative and Secure) is an integral, light water cooled, medium power reactor. IRIS has been selected as an International Near Term Deployable (INTD) reactor, within the Generation IV International Forum activities. The IRIS concept addresses the key-requirements defined by the US DOE for next generation reactors, i.e. enhanced reliability and safety, and improved economics. It features innovative, advanced engineering, but it is firmly based on the proven technology of pressurized water reactors (PWR). An innovative safety approach has been developed to mitigate the IRIS response to small-to-medium Loss of Coolant Accident (LOCA). This strategy is based on the interaction of IRIS compact containment with the reactor vessel to limit initial blowdown, and on depressurization through the use of a passive Emergency Heat Removal System (EHRS). A small Automatic Depressurization System (ADS) provides supplementary depressurization capability. A pressure suppression system is provided to limit the pressure peak following the initial blowdown to well below the containment design limit. The ultimate result is that during a small-to-medium LOCA, the core remains covered for an extended period of time, without credit for emergency water injection or external core makeup. The IRIS LOCA response is based on 'maintaining water inventory' rather than on the principle of safety injection. This novel safety approach poses significant issues for computational and analysis methods since the IRIS vessel and containment are strongly coupled, and the system response is based on the interaction between the two. The small break LOCA was calculated using RELAP5/mod3.3 and GOTHIC codes. Break of the largest line connected to the IRIS Reactor Pressure Vessel (RPV) was analyzed. The results of the calculations confirmed good performance of the IRIS system during LOCA. (author)

  10. IRIS pre-application licensing

    International Nuclear Information System (INIS)

    Carelli, Mario D.; Kling, Charles L.; Ritterbusch, Stanley E.

    2003-01-01

    This paper presents the approach to pre-application licensing by the International Reactor Innovative and Secure (IRIS), and advanced, integral reactor design with a thermal power of 1000 MW. The rationale for the pre-application licensing is discussed. Since IRIS technology is based on proven LWR experience, the project will rely on AP600/AP1000 precedent and will focus during the pre-application on long lead and novel items. A discussion of the evolution of the project to significantly reduce licensing issues is provided, followed by a summary of the IRIS safety-by-design which provides a formidable first step in the Defense in Depth approach. The effects of the safety-by-design, as well as of passive systems, on the IRIS safety will be investigated in a proposed testing program that will be reviewed by NRC during the pre-application. Documentation to be provided to NRC is discussed. Early design analyses indicate that the benefits of the IRIS safety-by-design approach are so significant that the basic premise of current emergency planning regulations (i.e., likelihood of core damage) will be reduced to the extent that special emergency response planning beyond the exclusion area boundary may not be needed. How this very significant outcome can be effected through a highly risk-informed licensing is discussed. (author)

  11. Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CT

    International Nuclear Information System (INIS)

    Hwang, Hye Jeon; Seo, Joon Beom; Lee, Jin Seong; Song, Jae Woo; Lee, Hyun Joo; Lim, Chae Hun; Kim, Song Soo

    2012-01-01

    To determine whether the image quality (IQ) is improved with iterative reconstruction in image space (IRIS), and whether IRIS can be used for radiation reduction in chest CT. Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying a dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from a single tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Objective noise was measured. The subjective IQ was evaluated by radiologists for the followings: noise, contrast and sharpness of mediastinum and lung. Objective noise was significantly lower in H-IRIS than in F-FBP (p < 0.01). In both SDCT and LDCT, the IQ scores were highest in F-IRIS, followed by F-FBP, H-IRIS and H-FBP, except those for sharpness of mediastinum, which tended to be higher in FBP. When comparing CT images between the same dose and different reconstruction (F-IRIS/F-FBP and H-IRIS/H-FBP) algorithms, scores tended to be higher in IRIS than in FBP, being more distinct in half-dose images. However, despite the use of IRIS, the scores were lower in H-IRIS than in F-FBP. IRIS generally helps improve the IQ, being more distinct at the reduced radiation. However, reduced radiation by half results in IQ decrease even when using IRIS in chest CT.

  12. CUSTOMER SATISFACTION IN AN SME: A CUSTOMER PERSPECTIVE IN PERCEIVED VALUE AND LOCAL BRAND IMAGE

    OpenAIRE

    Yulianti F.; Zamrudi Z.

    2017-01-01

    This study is aimed to understand the relationship of perceived quality and brand image on customer satisfaction of Sasirangan Consumer. The study were taken at Banjarmasin, South Kalimantan Province, Indonesia. The object of this study is SME’s Sasirangan (Kain Sasirangan). The object was taken since it has a deep local wisdom and deep meaning for Banjarmasin society (Banua). The subject taken in this research is youngsters at college. This group of subject taken since today’s youngsters has...

  13. Iris - nimi marmortahvlilt / Tiit Tuumalu

    Index Scriptorium Estoniae

    Tuumalu, Tiit, 1971-

    2003-01-01

    Briti kirjanikust Iris Murdochist pajatava inglise-ameerika mängufilmist "Iris" eesti videolevisse jõudmise puhul. Võrreldakse inglise teatrilavastaja Richard Eyre filmidebüüti Elmo Nüganeni debüütfilmiga "Nimed marmortahvlil"

  14. Customer Relations Management sebagai Salah Satu Upaya Public Relations Perusahaan Jasa Perbankan Menciptakan Good Image

    Directory of Open Access Journals (Sweden)

    Prima Ayu Rizqi Mahanani

    2017-01-01

    Full Text Available This article deals with marketing trends in the 21st century is shifting from a transactional approach to the relational approach with focus on the fulfillment of needs, satisfaction, and pleasure affect business banking customers are very dependent on the customer. Map business services banking services fickle demands creativity public relations in providing the best service to its customers get a good image. Service concept using the service paradigm leading to cultivate the power of the customer based on the customer satisfaction-oriented, widely used by business banking services at this time. Paradigms that focus on how to provide services to the customer so that the customer was satisfied, beyond what can be given to something that is important and not to be underestimated. Skills to understand and fulfill customer expectations should be every company’s business philosophy of banking services and customer relationship management is a strategy

  15. Conversion from mutual helicity to self-helicity observed with IRIS

    Science.gov (United States)

    Li, L. P.; Peter, H.; Chen, F.; Zhang, J.

    2014-10-01

    Context. In the upper atmosphere of the Sun observations show convincing evidence for crossing and twisted structures, which are interpreted as mutual helicity and self-helicity. Aims: We use observations with the new Interface Region Imaging Spectrograph (IRIS) to show the conversion of mutual helicity into self-helicity in coronal structures on the Sun. Methods: Using far UV spectra and slit-jaw images from IRIS and coronal images and magnetograms from SDO, we investigated the evolution of two crossing loops in an active region, in particular, the properties of the Si IV line profile in cool loops. Results: In the early stage two cool loops cross each other and accordingly have mutual helicity. The Doppler shifts in the loops indicate that they wind around each other. As a consequence, near the crossing point of the loops (interchange) reconnection sets in, which heats the plasma. This is consistent with the observed increase of the line width and of the appearance of the loops at higher temperatures. After this interaction, the two new loops run in parallel, and in one of them shows a clear spectral tilt of the Si IV line profile. This is indicative of a helical (twisting) motion, which is the same as to say that the loop has self-helicity. Conclusions: The high spatial and spectral resolution of IRIS allowed us to see the conversion of mutual helicity to self-helicity in the (interchange) reconnection of two loops. This is observational evidence for earlier theoretical speculations. Movie associated with Fig. 1 and Appendix A are available in electronic form at http://www.aanda.org

  16. IRIS Toxicological Review of Benzo[a]pyrene (Interagency ...

    Science.gov (United States)

    In January 2017, EPA finalized the IRIS assessment of Benzo[a]pyrene. The Toxicological Review was reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science discussion materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Benzo[a]pyrene are posted on this site. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for benzo[a]pyrene (BaP). The outcome of this project is an updated Toxicological Review and IRIS Summary for BaP that will be entered into the IRIS database.

  17. IRIS Toxicological Review of Tetrahydrofuran (THF) ...

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review of Tetrahydrofuran, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for tetrahydrofuran. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  18. Retinal vascular caliber, iris color, and age-related macular degeneration in the Irish Nun Eye Study.

    Science.gov (United States)

    McGowan, Amy; Silvestri, Giuliana; Moore, Evelyn; Silvestri, Vittorio; Patterson, Christopher C; Maxwell, Alexander P; McKay, Gareth J

    2014-12-18

    To evaluate the relationship between retinal vascular caliber (RVC), iris color, and age-related macular degeneration (AMD) in elderly Irish nuns. Data from 1233 participants in the cross-sectional observational Irish Nun Eye Study were assessed from digital photographs with a standardized protocol using computer-assisted software. Macular images were graded according to the modified Wisconsin Age-related Maculopathy Grading System. Regression models were used to assess associations, adjusting for age, mean arterial blood pressure, body mass index, refraction, and fellow RVC. In total, 1122 (91%) participants had gradable retinal images of sufficient quality for vessel assessment (mean age: 76.3 years [range, 56-100 years]). In an unadjusted analysis, we found some support for a previous finding that individuals with blue iris color had narrower retinal venules compared to those with brown iris color (P < 0.05), but this was no longer significant after adjustment. Age-related macular degeneration status was categorized as no AMD, any AMD, and late AMD only. Individuals with any AMD (early or late AMD) had significantly narrower arterioles and venules compared to those with no AMD in an unadjusted analysis, but this was no longer significant after adjustment. A nonsignificant reduced risk of any AMD or late AMD only was observed in association with brown compared to blue iris color, in both unadjusted and adjusted analyses. Retinal vascular caliber was not significantly associated with iris color or early/late AMD after adjustment for confounders. A lower but nonsignificant AMD risk was observed in those with brown compared to blue iris color. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  19. Effect of tamsulosin on iris vasculature and morphology

    Science.gov (United States)

    Shtein, Roni M.; Hussain, Munira T.; Cooney, Theresa M.; Elner, Victor M.; Hood, Christopher T.

    2015-01-01

    PURPOSE To determine whether preoperative iris vasculature and morphology are altered in patients who have taken tamsulosin (Flomax). SETTING Academic multispecialty practice. DESIGN Case series. METHODS Patients with current or past tamsulosin use and age- and sex-matched control patients were included. Anterior segment optical coherence tomography (AS-OCT) and iris fluorescein angiography were performed to measure iris vasculature and thickness before cataract surgery. Data collected at surgery included pupil diameter, clinical signs of intraoperative floppy-iris syndrome, and surgical complications. RESULTS Tamsulosin was currently used by 16 patients and in the past by 4 patients; the control group comprised 10 patients. Pharmacologically dilated pupil diameter was significantly smaller preoperatively and immediately postoperatively in the tamsulosin group than in the control group (P = .009 and P = .003, respectively). There was a statistically significant decrease in pupil size intraoperatively in the tamsulosin group (P = .05) but not in the control group (P = .3). Iris-vasculature parameters, specifically time to first vessel fill and percentage of vessel fill on iris fluorescein angiography, were not significantly different between the 2 groups. The AS-OCT measurements of iris morphology were not statistically significantly different between the groups. No surgical complications occurred. No fluorescein dye leakage, staining, or other vascular anomalies were observed. CONCLUSIONS Although there were differences in pupil measurements and intraoperative iris behavior between patients who had been on tamsulosin and control patients, there were no significant differences in iris vasculature on iris fluorescein angiography or in iris morphology on AS-OCT. PMID:24631201

  20. A new method for generating an invariant iris private key based on the fuzzy vault system.

    Science.gov (United States)

    Lee, Youn Joo; Park, Kang Ryoung; Lee, Sung Joo; Bae, Kwanghyuk; Kim, Jaihie

    2008-10-01

    Cryptographic systems have been widely used in many information security applications. One main challenge that these systems have faced has been how to protect private keys from attackers. Recently, biometric cryptosystems have been introduced as a reliable way of concealing private keys by using biometric data. A fuzzy vault refers to a biometric cryptosystem that can be used to effectively protect private keys and to release them only when legitimate users enter their biometric data. In biometric systems, a critical problem is storing biometric templates in a database. However, fuzzy vault systems do not need to directly store these templates since they are combined with private keys by using cryptography. Previous fuzzy vault systems were designed by using fingerprint, face, and so on. However, there has been no attempt to implement a fuzzy vault system that used an iris. In biometric applications, it is widely known that an iris can discriminate between persons better than other biometric modalities. In this paper, we propose a reliable fuzzy vault system based on local iris features. We extracted multiple iris features from multiple local regions in a given iris image, and the exact values of the unordered set were then produced using the clustering method. To align the iris templates with the new input iris data, a shift-matching technique was applied. Experimental results showed that 128-bit private keys were securely and robustly generated by using any given iris data without requiring prealignment.

  1. Iris reconstruction using artificial iris prosthesis for management of aniridia.

    Science.gov (United States)

    Mostafa, Yehia S; Osman, Amr A; Hassanein, Dina H; Zeid, Ashraf M; Sherif, Ahmed M

    2018-01-01

    To discuss the limitations and benefits of the BrightOcular prosthetic artificial iris device in management of aniridia associated with aphakia or cataract. This is a retrospective study including 5 eyes of 4 patients who underwent implantation of the BrightOcular iris prosthesis (Stellar Devices) for total or partial aniridia. The cases included 2 eyes of 1 patient with congenital aniridia associated with congenital cataract and 3 eyes with traumatic aniridia: 1 with subluxated cataractous lens and 2 with aphakia. In all cases, the iris prosthesis was implanted after a 3-piece acrylic intraocular lens was implanted. We evaluated the clinical course with a minimum follow-up period of 6 months, the intraoperative and postoperative complications, and the cosmetic satisfaction of patients. All patients had improved uncorrected distance visual acuity and best-corrected distance visual acuity. All patients had a transient corneal edema that resolved within the first postoperative week. Only the patient with congenital aniridia had a permanent increase in intraocular pressure and developed a band keratopathy throughout a 2-year follow-up period. The prosthesis was well-centered in all eyes except for one case that required scleral suture fixation after 3 months. All patients had a satisfactory cosmetic appearance. BrightOcular iris prosthesis is a safe and useful tool to correct aniridia associated with pseudophakia or aphakia. Being foldable, it is easy to be implanted through a small incision and placed in the ciliary sulcus without sutures when properly sized. Cosmetic results are satisfactory. Sizing methods should be improved.

  2. IRIS - A concept for microwave sensing of soil moisture and ocean salinity

    Science.gov (United States)

    Moghaddam, M.; Njoku, E.

    1997-01-01

    A concept is described for passive microwave sensing of soil moisture and ocean salinity from space. The Inflatable Radiometric Imaging System (IRIS) makes use of a large-diameter, offset-fed, parabolic-torus antenna with multiple feeds, in a conical pushbroom configuration.

  3. Iris melanocytoma.

    Science.gov (United States)

    Radovanović, Anica Bobić; Krnjaja, Bojana Dacić; Jaksić, Vesna

    2016-01-01

    Iris melanocytoma (IM) is a rare benign tumor, but unavoidable in differential diagnosis of pigmented iris lesions. According to the best knowledge of the authors it is for the first time in Serbia that a well-documented case of IM is presented and that the problem of this tumor is discussed. In the left eye of a 47-year-old white female at the iris in a six o'clock position, a highly pigmented, dome shaped lesion with a crater-like cavity in the center and with feathery margins was noticed. There were no signs of infiltration of surrounding tissue or intrinsic vessels and the lens was clear. Visual acuity and intraocular pressure were normal. An ultrasound biomicroscopy (UBM) revealed a well-defined lesion with high internal reflectivity, with a base diameter of 1.25 mm and a thickness of 0.80 mm in the periphery, and 0.53 mm in the central part.The diagnosis of IM of the left eye was established and regular checkups were performed for ten years. No changes in clinical or UBM presentation were established. Awareness of clinical presentation of IM is most important for correct diagnosis. Ultrasound biomicroscopy is a useful diagnostic procedure in the following up of IM.

  4. Role of Arbuscular Mycorrhizal Fungi on Iris

    Directory of Open Access Journals (Sweden)

    CHEN Yuan

    2014-06-01

    Full Text Available For efficiency using the amphibious plant iris to restore polluted water, the promoting effect of different arbuscular mycorrhiza fungi(AMFon iris was investigated, by monitoring the plant growth index, the physicochemical properties of the soil and the plant photosynthesis indexes. The result showed that the promoting effects of the AMF on the aboveground part and the underground part of the iris were based on different mechanism. For the underground part of the iris, the AMF stimulated its growth through the nutrient enrichment which was performed by the enormous hypha network. The nitrogen absorbing rate of the G. mosseae and the G. intraradices infected iris increased about 71.75% and 42.55%, and the phosphorous absorbing rate increased 8.36% and 9.5% separately. For the aboveground part of the iris, the AMF strengthened the conductance of the leaves’ stomas to control the balance between the net photosynthesis rate and the transpiration rate, so that the utilization rate of water resources was optimized, the metabolic rate was accelerated and the growth of the plant was promoted eventually. In this study, the promoting effect of the G. mosseae on the photosynthesis rate of the iris was significantly better than that of the G. intraradices(P<0.05.

  5. ELLERMAN BOMBS AT HIGH RESOLUTION. III. SIMULTANEOUS OBSERVATIONS WITH IRIS AND SST

    Energy Technology Data Exchange (ETDEWEB)

    Vissers, G. J. M.; Voort, L. H. M. Rouppe van der; Rutten, R. J.; Carlsson, M.; Pontieu, B. De, E-mail: g.j.m.vissers@astro.uio.no [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, NO-0315 Oslo (Norway)

    2015-10-10

    Ellerman bombs (EBs) are transient brightenings of the extended wings of the solar Balmer lines in emerging active regions. We describe their properties in the ultraviolet lines sampled by the Interface Region Imaging Spectrograph (IRIS), using simultaneous imaging spectroscopy in Hα with the Swedish 1-m Solar Telescope (SST) and ultraviolet images from the Solar Dynamics Observatory for Ellerman bomb detection and identification. We select multiple co-observed EBs for detailed analysis. The IRIS spectra strengthen the view that EBs mark reconnection between bipolar kilogauss fluxtubes with the reconnection and the resulting bi-directional jet located within the solar photosphere and shielded by overlying chromospheric fibrils in the cores of strong lines. The spectra suggest that the reconnecting photospheric gas underneath is heated sufficiently to momentarily reach stages of ionization normally assigned to the transition region and the corona. We also analyze similar outburst phenomena that we classify as small flaring arch filaments and ascribe to reconnection at a higher location. They have different morphologies and produce hot arches in million-Kelvin diagnostics.

  6. Iris double recognition based on modified evolutionary neural network

    Science.gov (United States)

    Liu, Shuai; Liu, Yuan-Ning; Zhu, Xiao-Dong; Huo, Guang; Liu, Wen-Tao; Feng, Jia-Kai

    2017-11-01

    Aiming at multicategory iris recognition under illumination and noise interference, this paper proposes a method of iris double recognition based on a modified evolutionary neural network. An equalization histogram and Laplace of Gaussian operator are used to process the iris to suppress illumination and noise interference and Haar wavelet to convert the iris feature to binary feature encoding. Calculate the Hamming distance for the test iris and template iris , and compare with classification threshold, determine the type of iris. If the iris cannot be identified as a different type, there needs to be a secondary recognition. The connection weights in back-propagation (BP) neural network use modified evolutionary neural network to adaptively train. The modified neural network is composed of particle swarm optimization with mutation operator and BP neural network. According to different iris libraries in different circumstances of experimental results, under illumination and noise interference, the correct recognition rate of this algorithm is higher, the ROC curve is closer to the coordinate axis, the training and recognition time is shorter, and the stability and the robustness are better.

  7. Checking the new IRI model: The bottomside B parameters

    International Nuclear Information System (INIS)

    Mosert, M.; Buresova, D.; Miro, G.; Lazo, B.; Ezquer, R.

    2003-01-01

    Electron density profiles obtained at Pruhonice (50.0, 15.0), El Arenosillo (37.1, 353.2) and Havana (23, 278) were used to check the bottom-side B parameters BO (thickness parameter) and B1 (shape parameter) predicted by the new IRI - 2000 version. The electron density profiles were derived from ionograms using the ARP technique. The data base includes daytime and nighttime ionograms recorded under different seasonal and solar activity conditions. Comparisons with IRI predictions were also done. The analysis shows that: a) The parameter B1 given by IRI 2000 reproduces better the observed ARP values than the IRI-90 version and b) The observed BO values are in general well reproduced by both IRI versions: IRI-90 and IRI-2000. (author)

  8. Checking the new IRI model The bottomside B parameters

    CERN Document Server

    Mosert, M; Ezquer, R; Lazo, B; Miro, G

    2002-01-01

    Electron density profiles obtained at Pruhonice (50.0, 15.0), El Arenosillo (37.1, 353.2) and Havana (23, 278) were used to check the bottom-side B parameters BO (thickness parameter) and B1 (shape parameter) predicted by the new IRI - 2000 version. The electron density profiles were derived from ionograms using the ARP technique. The data base includes daytime and nighttime ionograms recorded under different seasonal and solar activity conditions. Comparisons with IRI predictions were also done. The analysis shows that: a) The parameter B1 given by IRI 2000 reproduces better the observed ARP values than the IRI-90 version and b) The observed BO values are in general well reproduced by both IRI versions: IRI-90 and IRI-2000.

  9. ANTESEN CUSTOMER LOYALTY PADA BUDGET HOTEL

    OpenAIRE

    Latifa Rahma

    2016-01-01

    This research discusses the effects of Service Quality on Customer Satisfaction, Customer Loyalty, and Brand Image Budget hotel (Five Budget Hotel Managed by local chain hotel). The purpose of this study were 1) to analyze the effects of Service Quality on Customer Satisfaction, 2) to analyze the effects of Service Quality on Customer Loyalty, 3) to analyze the effect of Customer Satisfaction to Customer Loyalty, 4) to analyze the effects of Service Quality on the Brand Image, 5 ) to analyze ...

  10. Double hump sign in indentation gonioscopy is correlated with presence of plateau iris configuration regardless of patent iridotomy.

    Science.gov (United States)

    Kiuchi, Yoshiaki; Kanamoto, Takashi; Nakamura, Takao

    2009-02-01

    A plateau iris is one of the clinical forms of angle closure glaucoma. In patients with a patent iridotomy, the double hump sign detected during indentation gonioscopy has been reported to indicate the existence of a plateau iris configuration. The purpose of this study was to determine whether the double hump sign is correlated with the presence of the plateau iris syndrome regardless of the patency of the iridotomy. Five women and 3 men without a patent iridotomy presented with narrow angles on gonioscopy and a double hump sign on indentation gonioscopy. Ultrasound biomicroscopy (UBM) imaging was performed to determine the etiology of the narrow angle and double hump sign, and to determine the appropriate treatment to prevent the progression of visual field damage. Ten patients with narrow angles and without a double hump sign were also examined by UBM to serve as a control group. All 8 patients who showed double hump sign had a short iris root, which was inserted anterior to the ciliary face, a typical anatomic appearance of a plateau iris. On the other hand, only 1 eye of 10 eyes in control group appeared to have a plateau iris. A double hump sign observed on indentation gonioscopy is strongly correlated with the presence of a plateau iris, and therefore a useful indicator of a plateau iris configuration regardless of the patency of a laser iridotomy. Thus, a plateau iris configuration can be detected without using a UBM in many cases.

  11. THE INFLUENCE OF PRICE AND SERVICE QUALITY OF BRAND IMAGE AND ITS IMPACT ON CUSTOMER SATISFACTION GOJEK (STUDENTS STUDY ON A STATE UNIVERSITY OF JAKARTA)

    OpenAIRE

    Rizan, Mohammad; Yulianti, Dahliana; Rahmi, Rahmi

    2015-01-01

    The purpose of the research are to: test empirically influence of price to brand image on customer satisfaction Gojek, test empirically influence of service quality to brand image on customer satisfaction Gojek, test empirically influence of price on customer satisfaction Gojek, test empirically influence of service quality on customer satisfaction Gojek, test empirically influence of brand image on customer satisfaction Gojek. This study used confirmatory factor analysis. The research was co...

  12. Balloon cell nevus of the iris.

    Science.gov (United States)

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  13. Iris's Functional Description using Zernike polynomials

    International Nuclear Information System (INIS)

    Munnoz, D. P.; Silva Mata, F. J.; Talavera, I.; Hernandez, N.; Augier, A.

    2012-01-01

    The main goal of this work is the texture representation of the iris original image by means of functional data. The essence of the method consists in obtaining an adjusted vector of coefficients by means of a least square approximation starting from the representation of the original image by the expansion on the two-dimensional Zernike basis. This type of representation provides remarkable advantages regarding other representations e.g. the appreciable reduction of the dimension of the data, the simplification of the general process of the image and those characteristics of the functional data analysis. The carried out experiments demonstrate the feasibility of this approach and they allowed determining the optimal dimension of the coefficients vectors by means of the minimization of the residual errors. To corroborate the effectiveness of this representation, some experiments on identification were carried out on international databases whose initial results are annexed in the work. (Author)

  14. Fluid and structure coupling analysis of the interaction between aqueous humor and iris.

    Science.gov (United States)

    Wang, Wenjia; Qian, Xiuqing; Song, Hongfang; Zhang, Mindi; Liu, Zhicheng

    2016-12-28

    Glaucoma is the primary cause of irreversible blindness worldwide associated with high intraocular pressure (IOP). Elevated intraocular pressure will affect the normal aqueous humor outflow, resulting in deformation of iris. However, the deformation ability of iris is closely related to its material properties. Meanwhile, the passive deformation of the iris aggravates the pupillary block and angle closure. The nature of the interaction mechanism of iris deformation and aqueous humor fluid flow has not been fully understood and has been somewhat a controversial issue. The purpose here was to study the effect of IOP, localization, and temperature on the flow of the aqueous humor and the deformation of iris interacted by aqueous humor fluid flow. Based on mechanisms of aqueous physiology and fluid dynamics, 3D model of anterior chamber (AC) was constructed with the human anatomical parameters as a reference. A 3D idealized standard geometry of anterior segment of human eye was performed. Enlarge the size of the idealization geometry model 5 times to create a simulation device by using 3D printing technology. In this paper, particle image velocimetry technology is applied to measure the characteristic of fluid outflow in different inlet velocity based on the device. Numerically calculations were made by using ANSYS 14.0 Finite Element Analysis. Compare of the velocity distributions to confirm the validity of the model. The fluid structure interaction (FSI) analysis was carried out in the valid geometry model to study the aqueous flow and iris change. In this paper, the validity of the model is verified through computation and comparison. The results indicated that changes of gravity direction of model significantly affected the fluid dynamics parameters and the temperature distribution in anterior chamber. Increased pressure and the vertical position increase the velocity of the aqueous humor fluid flow, with the value increased of 0.015 and 0.035 mm/s. The results

  15. Distribution and multiplication of iris severe mosaic potyvirus in bulbous Iris in relation to metabolic activity : implications for ISMV detection

    NARCIS (Netherlands)

    Vlugt, van der C.I.M.

    1994-01-01

    During cultivation of iris, several viruses may cause severe damage like yield reduction and discoloration of the plant. In commercial stocks in the Netherlands virtually all plants are infected with iris mild mosaic virus (IMMV) while iris severe mosaic virus (ISMV) and narcissus latent

  16. IRIS Simplified LERF Model

    International Nuclear Information System (INIS)

    Maioli, A.; Finnicum, D.J.; Kumagai, Y.

    2004-01-01

    Westinghouse is currently conducting the pre-application licensing of the International Reactor Innovative and Secure (IRIS). One of the key aspects of the IRIS design is its safety-by-designTM philosophy and within this framework the PRA is being used as an integral part of the design process. The most ambitious risk-related goal for IRIS is to reduce the Emergency Planning Zone (EPZ) to within the exclusion area by demonstrating that the off-site doses are consistent with the US Protective Action Guidelines (PAGs) for initiation of emergency response so that the required protective actions would be limited to the exclusion area. As a first step, a model has been developed to provide a first order approximation of the Large Early Release Frequency (LERF) as a surrogate predictor of the off-site doses. A key-aspect of the LERF model development is the characterization of the possible paths of release. Four main categories have been historically pointed out: (1) Core Damage (CD ) sequences with containment bypass, (2) CD sequences with containment isolation failure, (3) CD sequences with containment failure at low pressure and (4) CD sequences with containment failure at high pressure. They have been reevaluated to account for the IRIS design features

  17. Prominence and tornado dynamics observed with IRIS and THEMIS

    Science.gov (United States)

    Schmieder, Brigitte; Levens, Peter; Labrosse, Nicolas; Mein, Pierre; Lopez Ariste, Arturo; Zapior, Maciek

    2017-08-01

    Several prominences were observed during campaigns in September 2013 and July 2014 with the IRIS spectrometer and the vector magnetograph THEMIS (Tenerife). SDO/AIA and IRIS provided images and spectra of prominences and tornadoes corresponding to different physical conditions of the transition region between the cool plasma and the corona. The vector magnetic field was derived from THEMIS observations by using the He D3 depolarisation due to the magnetic field. The inversion code (PCA) takes into account the Hanle and Zeeman effects and allows us to compute the strength and the inclination of the magnetic field which is shown to be mostly horizontal in prominences as well as in tornadoes. Movies from SDO/AIA in 304 A and Hinode/SOT in Ca II show the highly dynamic nature of the fine structures. From spectra in Mg II and Si IV lines provided by IRIS and H-alpha observed by the Multi-channel Subtractive Double Pass (MSDP) spectrograph in the Meudon Solar Tower we derived the Doppler shifts of the fine structures and reconstructed the 3D structure of tornadoes. We conclude that the apparent rotation of AIA tornadoes is due to large-scale quasi-periodic oscillations of the plasma along more or less horizontal magnetic structures.

  18. Iris reactor development

    International Nuclear Information System (INIS)

    Paramonov, D.V.; Carelli, M.D.; Miller, K.; Lombardi, C.V.; Ricotti, M.E.; Todreas, N.E.; Greenspan, E.; Yamamoto, K.; Nagano, A.; Ninokata, H.; Robertson, J.; Oriolo, F.

    2001-01-01

    The development progress of the IRIS (International Reactor Innovative and Secure) nuclear power system is presented. IRIS is currently being developed by an international consortium of industry, laboratory, university and utility establishments, led by Westinghouse. It is aimed at achieving the four major objectives of the Generation IV nuclear systems, i.e., proliferation resistance, enhanced safety, economic competitiveness and reduced waste. The project first year activities, which are summarized here, were focused on core neutronics, in-vessel configuration, steam generator and containment design, safety approach and economic performance. Details of these studies are provided in parallel papers in these proceedings. (author)

  19. IRIS: Supporting & Managing the Research Life-Cycle

    Science.gov (United States)

    Bollini, Andrea; Mennielli, Michele; Mornati, Susanna; Palmer, David T.

    2016-01-01

    IRIS is a new Current Research Information System (CRIS) developed by Cineca to upgrade and replace two previous solutions that have been used by Italian universities in the last 10 years. At the end of 2015, sixty-three Italian institutions are using IRIS. One of the main components of IRIS is DSpace-CRIS, an open source solution that can also be…

  20. Effect of tamsulosin on iris vasculature and morphology.

    Science.gov (United States)

    Shtein, Roni M; Hussain, Munira T; Cooney, Theresa M; Elner, Victor M; Hood, Christopher T

    2014-05-01

    To determine whether preoperative iris vasculature and morphology are altered in patients who have taken tamsulosin (Flomax). Academic multispecialty practice. Case series. Patients with current or past tamsulosin use and age- and sex-matched control patients were included. Anterior segment optical coherence tomography (AS-OCT) and iris fluorescein angiography were performed to measure iris vasculature and thickness before cataract surgery. Data collected at surgery included pupil diameter, clinical signs of intraoperative floppy-iris syndrome, and surgical complications. Tamsulosin was currently used by 16 patients and in the past by 4 patients; the control group comprised 10 patients. Pharmacologically dilated pupil diameter was statistically significantly smaller preoperatively and immediately postoperatively in the tamsulosin group than in the control group (P=.009 and P=.003, respectively). There was a statistically significant decrease in pupil size intraoperatively in the tamsulosin group (P=.05) but not in the control group (P=.3). Iris-vasculature parameters, specifically time to first vessel fill and percentage of vessel fill on iris fluorescein angiography, were not significantly different between the 2 groups. The AS-OCT measurements of iris morphology were not statistically significantly different between the groups. No surgical complications occurred. No fluorescein dye leakage, staining, or other vascular anomalies were observed. Although there were differences in pupil measurements and intraoperative iris behavior between patients who had been on tamsulosin and control patients, there were no significant differences in iris vasculature on iris fluorescein angiography or in iris morphology on AS-OCT. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. THE INFLUENCE OF PRICE AND SERVICE QUALITY OF BRAND IMAGE AND ITS IMPACT ON CUSTOMER SATISFACTION GOJEK (STUDENTS STUDY ON A STATE UNIVERSITY OF JAKARTA

    Directory of Open Access Journals (Sweden)

    Mohammad Rizan

    2015-09-01

    Full Text Available The purpose of the research are to: test empirically influence of price to brand image on customer satisfaction Gojek, test empirically influence of service quality to brand image on customer satisfaction Gojek, test empirically influence of price on customer satisfaction Gojek, test empirically influence of service quality on customer satisfaction Gojek, test empirically influence of brand image on customer satisfaction Gojek. This study used confirmatory factor analysis. The research was conducted in State University of Jakarta and used purposive sampling techniques, while the data collecting technique used questionaire, SPSS and SEM LISREL for data processing. The result shows a significant influence of price and service quality for brand image and its impact on customer satisfaction.

  2. Evaluation of the Successfulness of A Green Program through Customer Perceived Quality, Brand Image, and Customer Satisfaction: A Case Study at Surabaya Plaza Hotel

    OpenAIRE

    Marsella Yeanette Hatane; Adinda Yosari; Felicia Christiana Hendautomo

    2012-01-01

    Every company try to build the brand image of their businesses by doing a green program as one of their strategies. This research aims to see the impacts of the implementation of a green program at Surabaya Plaza Hotel, Surabaya. 230 hotel customers were randomly chosen as the respondents. Through descriptive and Structural Equation Modelling (SEM) analysis, can be seen that technical quality brings insignificant negative impacts towards customer satisfaction. Meanwhile, functional quality an...

  3. HyspIRI Low Latency Concept and Benchmarks

    Science.gov (United States)

    Mandl, Dan

    2010-01-01

    Topics include HyspIRI low latency data ops concept, HyspIRI data flow, ongoing efforts, experiment with Web Coverage Processing Service (WCPS) approach to injecting new algorithms into SensorWeb, low fidelity HyspIRI IPM testbed, compute cloud testbed, open cloud testbed environment, Global Lambda Integrated Facility (GLIF) and OCC collaboration with Starlight, delay tolerant network (DTN) protocol benchmarking, and EO-1 configuration for preliminary DTN prototype.

  4. IRIS Final Technical Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    M. D. Carelli

    2003-11-03

    OAK-B135 This NERI project, originally started as the Secure Transportable Autonomous Light Water Reactor (STAR-LW) and currently known as the International Reactor Innovative and Secure (IRIS) project, had the objective of investigating a novel type of water-cooled reactor to satisfy the Generation IV goals: fuel cycle sustainability, enhanced reliability and safety, and improved economics. The research objectives over the three-year (1999-2002) program were as follows: First year: Assess various design alternatives and establish main characteristics of a point design; Second year: Perform feasibility and engineering assessment of the selected design solutions; Third year: Complete reactor design and performance evaluation, including cost assessment These objectives were fully attained and actually they served to launch IRIS as a full fledged project for eventual commercial deployment. The program did not terminate in 2002 at the end of the NERI program, and has just entered in its fifth year. This has been made possible by the IRIS project participants which have grown from the original four member, two-countries team to the current twenty members, nine countries consortium. All the consortium members work under their own funding and it is estimated that the value of their in-kind contributions over the life of the project has been of the order of $30M. Currently, approximately 100 people worldwide are involved in the project. A very important constituency of the IRIS project is the academia: 7 universities from four countries are members of the consortium and five more US universities are associated via parallel NERI programs. To date, 97 students have worked or are working on IRIS; 59 IRIS-related graduate theses have been prepared or are in preparation, and 41 of these students have already graduated with M.S. (33) or Ph.D. (8) degrees. This ''final'' report (final only as far as the NERI program is concerned) summarizes the work performed

  5. Iris recognition as a biometric method after cataract surgery.

    Science.gov (United States)

    Roizenblatt, Roberto; Schor, Paulo; Dante, Fabio; Roizenblatt, Jaime; Belfort, Rubens

    2004-01-28

    Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical) distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure.

  6. IRIS Toxicological Review of n-Butanol (Interagency Science ...

    Science.gov (United States)

    On September 8, 2011, the Toxicological Review of n-Butanol (External Review Draft) was released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process, introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments with EPA's response and the interagency science consultation draft of the IRIS Toxicological Review of n-Butanol and the charge to external peer reviewers are posted on this site. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for n-butanol. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  7. IRIS Toxicological Review of Dichloromethane (Methylene ...

    Science.gov (United States)

    EPA has finalized the Toxicological Review of Dichloromethane (Methylene Chloride): In support of the Integrated Risk Information System (IRIS). Now final, this assessment may be used by EPA’s program and regional offices to inform decisions to protect human health. This document presents background information and justification for the Intergrated Risk Information System (IRIS) Summary of the hazard and dose-response assessment of dichloromethane. IRIS Summaries may include oral reference dose (RfD) and inhalation reference concentration (RfC) values for chronic and other exposure durations, and a carcinogencity assessment. Internet/NCEA web site

  8. IRIS-economics review

    International Nuclear Information System (INIS)

    Miller, K.

    2005-01-01

    IRIS is a medium sized advanced light water cooled modular reactor being developed by an international Group led by Westinghouse/BNFL. This reactor design is aimed at a broad spectrum of Utilities looking to install nuclear capacity to match market demands, or at emerging Nations with specific financial constraints looking to strategically optimise their debit levels. The IRIS building block is a multiple module sized at 335 MWe, with a construction period of 3 years and a 60-year plant life. Modules can be installed individually or in parks. In the latter case, deployment can be in single modules or in pairs (twin-unit); both will be built in staggered fashion at time intervals as dictated by economic and market considerations. One of the unique features of IRIS is its ability to offer reduction in costs through increased experience 'Learning' at a single site: In construction, the principal benefit is derived for subsequent modules, and is dependent on maintaining the 'core' team throughout. This is particularly important if there is any significant period between the completion of say module 1 and the start of module 2. This time frame will be driven by the overall market size, projected growth in demand and the level of financial risk the utility is prepared to accept. Learning benefits in construction are derived from skills and experience retention impacting on reducing the number of inputs and construction time. Learning in operation may benefit from a certain delay between modules as this allows operators to build up their 'cumulative experience'. Reactor operations on day 1 would be significantly different from those of say 3 years later. These benefits would be passed on to modules 2 and 3, which would realise them from day 1. Learning in operation is dependent on the ability to retain within the organisation knowledge and records of key events. The benefits from Learning in operation may also be applicable to different sites, in different countries. It

  9. Iris Recognition Using Feature Extraction of Box Counting Fractal Dimension

    Science.gov (United States)

    Khotimah, C.; Juniati, D.

    2018-01-01

    Biometrics is a science that is now growing rapidly. Iris recognition is a biometric modality which captures a photo of the eye pattern. The markings of the iris are distinctive that it has been proposed to use as a means of identification, instead of fingerprints. Iris recognition was chosen for identification in this research because every human has a special feature that each individual is different and the iris is protected by the cornea so that it will have a fixed shape. This iris recognition consists of three step: pre-processing of data, feature extraction, and feature matching. Hough transformation is used in the process of pre-processing to locate the iris area and Daugman’s rubber sheet model to normalize the iris data set into rectangular blocks. To find the characteristics of the iris, it was used box counting method to get the fractal dimension value of the iris. Tests carried out by used k-fold cross method with k = 5. In each test used 10 different grade K of K-Nearest Neighbor (KNN). The result of iris recognition was obtained with the best accuracy was 92,63 % for K = 3 value on K-Nearest Neighbor (KNN) method.

  10. Edge detection of iris of the eye for human biometric identification system

    Directory of Open Access Journals (Sweden)

    Kateryna O. Tryfonova

    2015-03-01

    Full Text Available Method of human biometric identification by iris of the eye is considered as one of the most accurate and reliable methods of identification. Aim of the research is to solve the problem of edge detection of digital image of the human eye iris to be able to implement human biometric identification system by means of mobile device. To achieve this aim the algorithm of edge detection by Canny is considered in work. It consists of the following steps: smoothing, finding gradients, non-maximum suppression, double thresholding with hysteresis. The software implementation of the Canny algorithm is carried out for the Android mobile platform with the use of high level programming language Java.

  11. Simplified safety and containment systems for the iris reactor

    International Nuclear Information System (INIS)

    Conway, L.E.; Lombardi, C.; Ricotti, M.; Oriani, L.

    2001-01-01

    The IRIS (International Reactor Innovative and Secure) is a 100 - 300 MW modular type pressurized water reactor supported by the U.S. DOE NERI Program. IRIS features a long-life core to provide proliferation resistance and to reduce the volume of spent fuel, as well as reduce maintenance requirements. IRIS utilizes an integral reactor vessel that contains all major primary system components. This integral reactor vessel makes it possible to reduce containment size; making the IRIS more cost competitive. IRIS is being designed to enhance reactor safety, and therefore a key aspect of the IRIS program is the development of the safety and containment systems. These systems are being designed to maximize containment integrity, prevent core uncover following postulated accidents, minimize the probability and consequences of severe accidents, and provide a significant simplification over current safety system designs. The design of the IRIS containment and safety systems has been identified and preliminary analyses have been completed. The IRIS safety concept employs some unique features that minimize the consequences of postulated design basis events. This paper will provide a description of the containment design and safety systems, and will summarize the analysis results. (author)

  12. Iris recognition as a biometric method after cataract surgery

    Directory of Open Access Journals (Sweden)

    Roizenblatt Jaime

    2004-01-01

    Full Text Available Abstract Background Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Methods Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. Results A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Conclusions Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure.

  13. Spatula scaffold: An iris-sparing technique for lensectomy.

    Science.gov (United States)

    Narang, Priya; Agarwal, Amar

    2017-12-01

    Lensectomy with vitrectomy is often performed for crystalline lenticular subluxation. We report a new technique and a practical approach that involves the placement of a spatula beneath the iris tissue that facilitates retroiridial removal of subluxated lens and acts as a scaffold by protecting the iris tissue from being accidentally trapped into the vitrectomy cutter port. Our technique facilitates management of the lens and vitreous without any trauma to the iris and secondarily obviates the need to perform an iris repair procedure that may arise due to iatrogenic reasons.

  14. A giant traumatic iris cyst

    Directory of Open Access Journals (Sweden)

    Lott Pooi Wah

    2015-12-01

    Full Text Available A 52 year-old construction worker presented with progressive painful blurring of vision in the left eye associated with redness for past 1 month. There was a history of penetrating injury in the same eye 10 years ago and he underwent primary wound toilet and suturing, lens removal with intraocular lens implantation. Slit lamp examination revealed a corneal scar at 9’oclock, a large transilluminant iris cyst superotemporally and adherent to corneal endothelium. It was extended from angle of the pupil and obstructing the visual axis. The patient underwent excision of an iris cyst through superior limbal incision. Viscodissection was done to separate the cyst from the corneal endothelium and underlying iris stroma. Trypan blue ophthalmic solution was injected into the cyst to stain the cyst capsule. Post operatively 7 days, vision improved to 6/7.5 without complication. There was no recurrence up to 1 year postoperation. Histopathological finding revealed a benign cyst mass lined by simple cuboidal to nonkeratinized stratified squamous epithelium. We had achieved a good surgical outcome with no complication to date for our case study. We advocate this modified surgical method to completely remove iris cyst.

  15. UV and X-ray Evolution of AR12230 as Observed with IRIS and FOXSI-II

    Science.gov (United States)

    Ryan, Daniel; Christe, Steven; Glesener, Lindsay; Vievering, Julie; Krucker, Sam; Ishikawa, Shin-Nosuke

    2017-08-01

    We present a multi-spectral and spatio-temporal analysis of AR12230 using both UV and X-ray spectroscopic imaging obtained as part of a coordinated observing campaign on 11 December 2014. The campaign involved IRIS (Interface Region Imaging Spectrometer) -- which provides both UV imaging and slit spectrograph observations of optically thick chromospheric and transition region emission -- and FOXSI-II (Focusing Optics X-ray Solar Imager) -- the second in a series of sounding rocket flights which combines grazing incidence direct focusing optics to produce solar X-ray spectroscopic imaging in the range 4-15keV. The active region exhibits a prolonged compact brightening in the IRIS 1330 A and 1400 A slit-jaw channels near the center of the active region throughout the duration of the observations. In the early phase of the observations FOXSI-II shows an X-ray source approximately 20x20 arcsec centered at the same location. The X-ray spectra show the presence of hot (~8 MK) thermal plasma and is suggestive of the presence of non-thermal electrons.. Later, two additional transient, spatially extended, simultaneous brightenings are observed, one of which was captured by the IRIS slit spectrograph. We combine these observations to explore the evolution and topology of the active region. Hydrodynamic modeling of the chromosphere is used to place a limit on the amount of non-thermal electrons required to produce the observed UV emission. This result is then compared to the limit inferred from the FOXSI-II X-ray spectra. Thus, we explore the role of non-thermal electrons and hydrodynamics in the energization and evolution of plasma in active regions.

  16. Safety design features of the IRIS

    International Nuclear Information System (INIS)

    2009-01-01

    The International Reactor Innovative and Secure (IRIS) is an advanced, integral, light water cooled reactor of medium generating capacity (335 MW(e)), that features an integral reactor vessel containing all the reactor primary system components, including steam generators, coolant pumps, pressurizer and heaters, and control rod drive mechanisms; in addition to the typical core, internals, control rods and neutron reflector. This integral configuration allows for the use of a small, high design pressure, spherical steel containment which results in a significant reduction in the size of the nuclear island. Other IRIS innovations include a simplified passive safety system concept and equipment features that derive from the 'safety-by-design' philosophy. This design approach allows for elimination of certain accident initiators at the design stage, or when outright elimination is not possible, decreases accident consequences and/or their probability of occurrence. Major design characteristics of the IRIS are given. As part of the IRIS pre-application licensing review by the U.S. Nuclear Regulatory Commission (NRC), the IRIS design team has developed a test plan that will provide the necessary data for safety analysis computer model verification, as well as for verifying the manufacturing feasibility, operability, and durability of new component designs

  17. Proton beam radiotherapy of iris melanoma

    International Nuclear Information System (INIS)

    Damato, Bertil; Kacperek, Andrzej; Chopra, Mona; Sheen, Martin A.; Campbell, Ian R.; Errington, R. Douglas

    2005-01-01

    Purpose: To report on outcomes after proton beam radiotherapy of iris melanoma. Methods and Materials: Between 1993 and 2004, 88 patients with iris melanoma received proton beam radiotherapy, with 53.1 Gy in 4 fractions. Results: The patients had a mean age of 52 years and a median follow-up of 2.7 years. The tumors had a median diameter of 4.3 mm, involving more than 2 clock hours of iris in 32% of patients and more than 2 hours of angle in 27%. The ciliary body was involved in 20%. Cataract was present in 13 patients before treatment and subsequently developed in another 18. Cataract had a 4-year rate of 63% and by Cox analysis was related to age (p = 0.05), initial visual loss (p < 0.0001), iris involvement (p < 0.0001), and tumor thickness (p < 0.0001). Glaucoma was present before treatment in 13 patients and developed after treatment in another 3. Three eyes were enucleated, all because of recurrence, which had an actuarial 4-year rate of 3.3% (95% CI 0-8.0%). Conclusions: Proton beam radiotherapy of iris melanoma is well tolerated, the main problems being radiation-cataract, which was treatable, and preexisting glaucoma, which in several patients was difficult to control

  18. International Reactor Innovative and Secure (IRIS) summary

    International Nuclear Information System (INIS)

    Carelli, Mario D.

    2001-01-01

    The IRIS (International Reactor Innovative and Secure) reactor is described in the first part of the presentation. IRIS is a light water cooled reactor with an integral configuration, where steam generators, pumps and pressurizer are inside the reactor vessel. Partially funded by the DOE NERI program, IRIS is being developed by an international consortium of 16 organizations from seven countries. A key IRIS characteristic is its 'safety by design' approach which strives to eliminate, by design, as many accidents as possible rather than coping with their consequences. Initial returns are very positive; out of the eight Class IV accidents considered in the AP600 only one remains as a Class IV in IRIS, and at much reduced probability. Small-to-medium LOCAs have minimal consequences as the core remains safely under water for days, without the need for safety injection or water makeup. In spite of its novelty IRIS is firmly grounded on proven LWR technology and therefore a prototype is not needed to assure design certification. Rather, very extensive scaled tests will be performed to investigate the performance of in-vessel components such as steam generators and pumps, both individually and as interactive systems. Accident sequences will also be simulated and tested to prove IRIS safety by design claims. The first core fuel is less than 5% enriched and the fuel assembly is very similar to existing PWR assemblies, so there is no licensing challenge regarding the fuel. Because of the safety by design approach, yielding simplifications In design and accident management (e.g., IRIS does not have an emergency core cooling system), some accident scenarios are eliminated and others have lesser consequences. Thus, simplification and streamlining of the regulatory process might be possible. Risk informed regulation will be coupled with safety by design to show lower accident and damage probabilities. This could lead to a relaxation of siting regulatory requirements. It is

  19. Microdose fluorescence imaging of ABY-029 on an operating microscope adapted by custom illumination and imaging modules.

    Science.gov (United States)

    Elliott, Jonathan T; Dsouza, Alisha V; Marra, Kayla; Pogue, Brian W; Roberts, David W; Paulsen, Keith D

    2016-09-01

    Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system specifications are characterized, and in vivo efficacy of the system in detecting ABY-029 is evaluated in a rat orthotopic glioma model following microdose injections, showing the suitability of the device for microdose phase 0 clinical trials.

  20. Antigen-Specific Interferon-Gamma Responses and Innate Cytokine Balance in TB-IRIS

    Science.gov (United States)

    Goovaerts, Odin; Jennes, Wim; Massinga-Loembé, Marguerite; Ceulemans, Ann; Worodria, William; Mayanja-Kizza, Harriet; Colebunders, Robert; Kestens, Luc

    2014-01-01

    Background Tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) remains a poorly understood complication in HIV-TB patients receiving antiretroviral therapy (ART). TB-IRIS could be associated with an exaggerated immune response to TB-antigens. We compared the recovery of IFNγ responses to recall and TB-antigens and explored in vitro innate cytokine production in TB-IRIS patients. Methods In a prospective cohort study of HIV-TB co-infected patients treated for TB before ART initiation, we compared 18 patients who developed TB-IRIS with 18 non-IRIS controls matched for age, sex and CD4 count. We analyzed IFNγ ELISpot responses to CMV, influenza, TB and LPS before ART and during TB-IRIS. CMV and LPS stimulated ELISpot supernatants were subsequently evaluated for production of IL-12p70, IL-6, TNFα and IL-10 by Luminex. Results Before ART, all responses were similar between TB-IRIS patients and non-IRIS controls. During TB-IRIS, IFNγ responses to TB and influenza antigens were comparable between TB-IRIS patients and non-IRIS controls, but responses to CMV and LPS remained significantly lower in TB-IRIS patients. Production of innate cytokines was similar between TB-IRIS patients and non-IRIS controls. However, upon LPS stimulation, IL-6/IL-10 and TNFα/IL-10 ratios were increased in TB-IRIS patients compared to non-IRIS controls. Conclusion TB-IRIS patients did not display excessive IFNγ responses to TB-antigens. In contrast, the reconstitution of CMV and LPS responses was delayed in the TB-IRIS group. For LPS, this was linked with a pro-inflammatory shift in the innate cytokine balance. These data are in support of a prominent role of the innate immune system in TB-IRIS. PMID:25415590

  1. Using EO-1 Hyperion to Simulate HyspIRI Products for a Coniferous Forest: The Fraction of PAR Absorbed by Chlorophyll (fAPAR(sub chl)) and Leaf Water Content (LWC)

    Science.gov (United States)

    Zhang, Qingyuan; Middleton, Elizabeth M.; Gao, Bo-Cai; Cheng, Yen-Ben

    2011-01-01

    This study presents development of prototype products for terrestrial ecosystems in preparation for the future imaging spectrometer planned for the Hyperspectral Infrared Imager (HyspIRI) mission. We present a successful demonstration example in a coniferous forest of two product prototypes: fraction of photosynthetic active radiation (PAR) absorbed by chlorophyll of a canopy (fAPAR(sub chl)) and leaf water content (LWC), for future HyspIRI implementation at 60 m spatial resolution. For this, we used existing 30 m resolution imaging spectrometer data available from the Earth Observing One (EO-1) Hyperion satellite to simulate and prototype the level one radiometrically corrected radiance (L1R) images expected from the HyspIRI visible through shortwave infrared spectrometer. The HyspIRI-like images were atmospherically corrected to obtain surface reflectance, and spectrally resampled to produce 60 m reflectance images for wavelength regions that were comparable to all seven of the MODerate resolution Imaging Spectroradiometer (MODIS) land bands. Thus, we developed MODIS-like surface reflectance in seven spectral bands at the HyspIRI-like spatial scale, which was utilized to derive fAPARchl and LWC with a coupled canopy-leaf radiative transfer model (PROSAIL2) for the coniferous forest[1]. With this study, we provide additional evidence that the fAPARchl product is more realistic for describing the physiologically active canopy than the traditional fAPAR parameter for the whole canopy (fAPAR(sub canopy)), and thus should replace it in ecosystem process models to reduce uncertainties in terrestrial carbon cycle studies and ecosystem studies.

  2. A customer satisfaction model for a utility service industry

    Science.gov (United States)

    Jamil, Jastini Mohd; Nawawi, Mohd Kamal Mohd; Ramli, Razamin

    2016-08-01

    This paper explores the effect of Image, Customer Expectation, Perceived Quality and Perceived Value on Customer Satisfaction, and to investigate the effect of Image and Customer Satisfaction on Customer Loyalty of mobile phone provider in Malaysia. The result of this research is based on data gathered online from international students in one of the public university in Malaysia. Partial Least Squares Structural Equation Modeling (PLS-SEM) has been used to analyze the data that have been collected from the international students' perceptions. The results found that Image and Perceived Quality have significant impact on Customer Satisfaction. Image and Customer Satisfaction ware also found to have significantly related to Customer Loyalty. However, no significant impact has been found between Customer Expectation with Customer Satisfaction, Perceived Value with Customer Satisfaction, and Customer Expectation with Perceived Value. We hope that the findings may assist the mobile phone provider in production and promotion of their services.

  3. Iris Transponder-Communications and Navigation for Deep Space

    Science.gov (United States)

    Duncan, Courtney B.; Smith, Amy E.; Aguirre, Fernando H.

    2014-01-01

    The Jet Propulsion Laboratory has developed the Iris CubeSat compatible deep space transponder for INSPIRE, the first CubeSat to deep space. Iris is 0.4 U, 0.4 kg, consumes 12.8 W, and interoperates with NASA's Deep Space Network (DSN) on X-Band frequencies (7.2 GHz uplink, 8.4 GHz downlink) for command, telemetry, and navigation. This talk discusses the Iris for INSPIRE, it's features and requirements; future developments and improvements underway; deep space and proximity operations applications for Iris; high rate earth orbit variants; and ground requirements, such as are implemented in the DSN, for deep space operations.

  4. IRIS and the National Research Council (NRC)

    Science.gov (United States)

    Since the 2011 National Academies’ National Research Council (NRC) review of the IRIS Program's assessment of Formaldehyde, EPA and NRC have had an ongoing relationship into the improvements of developing the IRIS Assessments.

  5. Ethnicity distinctiveness through iris texture features using Gabor filters

    CSIR Research Space (South Africa)

    Mabuza-Hocquet, Gugulethu P

    2017-02-01

    Full Text Available Research in iris biometrics has been focused on utilizing iris features as a means of identity verification and authentication. However, not enough research work has been done to explore iris textures to determine soft biometrics such as gender...

  6. Barumiki antocyjanowe u Iris germanica [Anthocyanin pigments in Iris germanica L.

    Directory of Open Access Journals (Sweden)

    J. Szczepańska

    2015-06-01

    Full Text Available Anthocyanin pigments occurring in the flowers of Iris germanica were investigated in five varieties: Rota, Wedgewood, Empress of India, Deputate Nomblot and Joanna. The relation between the colour of the flower and the amount of the pigment was studied. The pigments were extracted from the dry plant material with 1% hydrochloric acid in methanol. Paper chromatography and colorimetric determinations were used for identification of the pigments and their quantitative determination. The results allow the following conclusions: 1. The varieties investigated were characterized toy the occurrence of delphinidine glycoside; 2. The colour intensity is dependent on the anthocyanin pigments; 3. The colour spectrum of Iris sp. flowersis greatly extended by yellow copigments.

  7. Iris Cryptography for Security Purpose

    Science.gov (United States)

    Ajith, Srighakollapu; Balaji Ganesh Kumar, M.; Latha, S.; Samiappan, Dhanalakshmi; Muthu, P.

    2018-04-01

    In today's world, the security became the major issue to every human being. A major issue is hacking as hackers are everywhere, as the technology was developed still there are many issues where the technology fails to meet the security. Engineers, scientists were discovering the new products for security purpose as biometrics sensors like face recognition, pattern recognition, gesture recognition, voice authentication etcetera. But these devices fail to reach the expected results. In this work, we are going to present an approach to generate a unique secure key using the iris template. Here the iris templates are processed using the well-defined processing techniques. Using the encryption and decryption process they are stored, traversed and utilized. As of the work, we can conclude that the iris cryptography gives us the expected results for securing the data from eavesdroppers.

  8. IRIS Toxicological Review of Acrolein (2003 Final)

    Science.gov (United States)

    EPA announced the release of the final report, Toxicological Review of Acrolein: in support of the Integrated Risk Information System (IRIS). The updated Summary for Acrolein and accompanying toxicological review have been added to the IRIS Database.

  9. IRIS: A global approach to nuclear power renaissance

    International Nuclear Information System (INIS)

    Carelli, M.D.

    2004-01-01

    Improved international reactor IRIS (International Reactor Innovative and Secure) is discussed. IRIS is defined as a modular reactor with integral arrangement and water coolant. Industrial companies, research, scientific groups and electric power producers of different countries (USA, Great Britain, Italy, Spain, Brazil, Russia, Mexico, Japan, Croatia) take part in the realization of IRIS. Basic parameters of the reactor, construction characteristics, arrangement are presented [ru

  10. Plateau iris Íris em platô

    Directory of Open Access Journals (Sweden)

    Alberto Diniz Filho

    2008-10-01

    Full Text Available The term plateau iris was first coined in 1958 to describe the iris configuration of a patient. Two years later the concept of plateau iris was published. In 1977, the plateau iris configuration was classically defined as presurgical changes of an eye with a relative normal central anterior chamber depth, flat iris by conventional biomicroscopy, but displaying an extremely narrow or closed angle on gonioscopic examination. On the other hand, the plateau iris syndrome was defined as an acute glaucoma crisis in one eye with a relative normal central anterior chamber depth and patent iridotomy on direct examination, presenting angle closure confirmed by gonioscopic examination after mydriasis. In 1992, the anatomic aspects of plateau iris were studied using ultrasound biomicroscopy. Finally, plateau iris has been considered an anatomic variant of iris structure in which the iris periphery angulates sharply forward from its insertion point and then again angulates sharply and centrally backward, along with an anterior positioning of the ciliary processes seen on ultrasound biomicroscopy. The clinical treatment of plateau iris syndrome is carried out with topical use of pilocarpine. However, the definitive treatment should be fulfilled by performing an argon laser peripheral iridoplasty.O termo íris em platô foi primeiramente inventado em 1958 para descrever a configuração da íris de um paciente. Dois anos depois o conceito de íris em platô foi publicado. Em 1977, a configuração de íris em platô foi classicamente definida como alterações pré-cirúrgicas de um olho com uma profundidade de câmara anterior relativamente normal, íris plana pela biomicroscopia convencional, mas mostrando um ângulo extremamente estreito ou fechado pela gonioscopia. Por outro lado, a síndrome de íris em platô foi definida como uma crise de glaucoma agudo em um olho com uma profundidade de câmara anterior relativamente normal e uma iridectomia patente ao

  11. Ionospheric Tomography from a Reference GPS/MET Experiment Through the IRI Model

    Directory of Open Access Journals (Sweden)

    Lung-Chih Tsai

    2006-01-01

    Full Text Available In earlier studies, we implemented the Multiplicative Algebraic Reconstruction Technique (MART to reconstruct two-dimensional ionospheric structures from measured TECs through the receptions of the GPS-to-LEO signals and/or the NNSS-to-ground beacon signals. To examine the accuracy of the reconstructed image we need ground-based validation systems which are difficult to obtain. However, such comparative investigation is needed if one aims to improve tomography inverse techniques and algorithms. In this study, we propose a simulation scheme to carry out this task. We first simulate the GPS-to-LEO TEC measurements through the IRI model by integrating electron densities along the ¡§straight¡¨ ray occultation paths between the GPS and LEO satellite obtained from the real GPS/MET experiment. Contiguous tomographic images are then derived by the MART algorithm within the ¡§reference¡¨ GPS/MET experiment. They are verified by comparison with the ¡§true¡¨ IRI-modelled ionosphere. We show that simulation/reference results can be used to find the optimal reconstruction strategy in space-based ionospheric tomography.

  12. IRIS Toxicological Review of Chloroform (Final Report)

    Science.gov (United States)

    EPA is announcing the release of the final report, Toxicological Review of Chloroform: in support of the Integrated Risk Information System (IRIS). The updated Summary for Chloroform and accompanying Quickview have also been added to the IRIS Database.

  13. THE ELECTRON DENSITY IN EXPLOSIVE TRANSITION REGION EVENTS OBSERVED BY IRIS

    Energy Technology Data Exchange (ETDEWEB)

    Doschek, G. A.; Warren, H. P. [Space Science Division, Naval Research Laboratory, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States); Young, P. R. [College of Science, George Mason University, 4400 University Drive, Fairfax, VA 22030 (United States)

    2016-11-20

    We discuss the intensity ratio of the O iv line at 1401.16 Å to the Si iv line at 1402.77 Å in Interface Region Imaging Spectrograph ( IRIS ) spectra. This intensity ratio is important if it can be used to measure high electron densities that cannot be measured using line intensity ratios of two different O iv lines from the multiplet within the IRIS wavelength range. Our discussion is in terms of considerably earlier observations made from the Skylab manned space station and other spectrometers on orbiting spacecraft. The earlier data on the O iv and Si iv ratio and other intersystem line ratios not available to IRIS are complementary to IRIS data. In this paper, we adopt a simple interpretation based on electron density. We adopt a set of assumptions and calculate the electron density as a function of velocity in the Si iv line profiles of two explosive events. At zero velocity the densities are about 2–3 × 10{sup 11} cm{sup -3}, and near 200 km s{sup -1} outflow speed the densities are about 10{sup 12} cm{sup -3}. The densities increase with outflow speed up to about 150 km s{sup -1} after which they level off. Because of the difference in the temperature of formation of the two lines and other possible effects such as non-ionization equilibrium, these density measurements do not have the precision that would be available if there were some additional lines near the formation temperature of O iv.

  14. Keskittymishäiriön kuvaaminen syanotypialla

    OpenAIRE

    Lammela, Maarit

    2017-01-01

    Toiminallisessa opinnäytetyössäni oli tavoitteena havainnollistaa kuvina luki- ja keskittymishäiriön tunnetiloja syanotypialla vedostaen. Projektissa tarkastelin ja tutkin itseäni. Havainnollistin kuvina yli viisikymmentä luonteenpiirrettä, jotka ovat tyypillisiä luki- ja keskittymishäiriöiselle ihmiselle. Näistä toteutin teoksiksi 25. Kuvasin itseäni ja tunnetilojani digikameralla itselaukaisinta apuna käyttäen. Halusin tehdä tämän työn kertoakseni luki- ja keskittymishäiriöisen ihmisen t...

  15. IRIS Toxicological Review of n-Butanol (External Review Draft ...

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of n-butanol that will appear in the Integrated Risk Information System (IRIS) database. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for n-butanol. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  16. Prevalence of plateau iris configuration in primary angle closure glaucoma using ultrasound biomicroscopy in the Indian population

    Directory of Open Access Journals (Sweden)

    Gaurav Kumar

    2012-01-01

    Full Text Available Purpose: To report the prevalence of plateau iris in patients with primary angle closure glaucoma (PACG, in North India. Materials and Methods: The patients with PACG, attending the glaucoma services at a tertiary care center in North India were included in the study. All patients had undergone Nd-YAG laser peripheral iridotomy at least four weeks prior to inclusion in the study. Four weeks prior to inclusion in the study, none of the patients had used pilocarpine. Ultrasound Biomicroscopy (UBM images were qualitatively evaluated and plateau iris configuration was defined in an eye if the following criteria were fulfilled in two or more quadrants: anteriorly directed ciliary process supporting the peripheral iris, steep rise of iris root from its point of insertion followed by a downward angulation from the corneoscleral wall, absent ciliary sulcus, and iridotrabecular contact in the same quadrant. Results: One hundred and one eyes were included in the study. There were 63 (62.4% females and 38 (37.6% males. The mean age of the patients was 57.8 ± 9.5 years (range: 42 to 78 years. The mean axial length in the study population was 22.2 ± 1.1 mm. The mean spherical equivalent refraction was 0.06 ± 1.12 D. The mean intraocular pressure was 18.5 ± 4.7 mmHg (range: 12 - 24 mmHg. Twenty-nine (28.7% subjects were diagnosed with plateau iris on the basis of above-defined criteria. Of the 29 eyes, 18 (62.1% subjects had plateau iris in two quadrants, nine (31.03% in three quadrants, and two (6.8% had this configuration in all the four quadrants. Conclusions: Approximately 30% of the eyes with PACG had plateau iris on UBM. Plateau iris was very often the cause for residual angle closure following laser peripheral iridotomy in Indian eyes with PACG.

  17. A bibliography of IRIS-related publications, 2000-2011

    Science.gov (United States)

    Muco, B.

    2012-12-01

    Citations and acknowledgements in scientific journals can be an indicator of the role an organization has on the research of that field. Since its formation and incorporation in May 1984, the IRIS Consortium (Incorporated Research Institutions for Seismology) is mentioned more and more as a valuable source of data, instruments and programs in the literature of earth sciences. As a large organization with more than 100 member domestic institutes and about 40 international affiliates, obviously IRIS has a direct impact on the earth sciences through all its programs, projects, workshops, symposia, and news¬letters and as a lively forum for exchanging ideas. In order to maintain support from National Science Foundation (NSF) and the research community, it is important to document the continued use of IRIS facilities in basic research programs. IRIS maintains a database of articles that are based on the use of IRIS facilities or which reference use of IRIS data and resources. Articles in this database have been either been provided to IRIS by the authors or selected through an annual search of a number of prominent journals. A text version of the full bibliographic database is available on the IRIS website and a version in EndNote format is also provided. To provide a more complete bibliography and a consistent evaluation of temporal tends in publications, a special annual search began in 2000 which focused on a subset of key seismology and Earth science journals: Bulletin of Seismological Society of America, Journal of Geophysical Research, Seismological Research Letters, Geophysical Research Letters, Earth and Planetary Science Letters, Physics of the Earth and Planetary Interiors, Tectonophysics, Geophysical Journal International, Nature, Science, Geology and EOS. Using different search engines as Scirus, ScienceDirect, GeoRef, OCLC First Search, EASI Search, NASA Abstract Service etc. for online journals and publishers' databases, we searched for key words (IRIS

  18. ANTESEN CUSTOMER LOYALTY PADA BUDGET HOTEL

    Directory of Open Access Journals (Sweden)

    Latifa Rahma

    2016-08-01

    Full Text Available This research discusses the effects of Service Quality on Customer Satisfaction, Customer Loyalty, and Brand Image Budget hotel (Five Budget Hotel Managed by local chain hotel. The purpose of this study were 1 to analyze the effects of Service Quality on Customer Satisfaction, 2 to analyze the effects of Service Quality on Customer Loyalty, 3 to analyze the effect of Customer Satisfaction to Customer Loyalty, 4 to analyze the effects of Service Quality on the Brand Image, 5  to analyze the influence of the Customer Satisfaction Brand Image, 6 to analyze the effect of Customer Loyalty to Brand Image. The design of this research using primary data obtained by distributing questionnaires to 250 respondents eligible stayed at the Budget Hotel at least 1 time in last 12 months. Respondents were selected using purposive sampling method and the data were analyzed using AMOS version 22.0 and SPSS version 22.0. The proposed model was tested using Structural Equation Modeling (SEM and analyzed using AMOS. This study shows that 1 Service Quality found to have an influence on Customer Satisfaction, 2 Service Quality found to have an influence on Customer Loyalty, 3 Customer Satisfaction is found to have an influence on Customer Loyalty, 4 Service Quality found to have an influence on brand image, 5 Customer Satisfaction is found to have an influence on Brand Image, 6 Customer Loyalty found to have an influence on the Brand Image. The results of this study concluded that there is a positive influence of the Service Quality on Brand Image through the Customer Satisfaction and Customer Loyalty. Future researches are recommended to increase the factor of First Impression, Favorable Location, Hotel

  19. IRIS Nuclear Power Plant design

    International Nuclear Information System (INIS)

    Carelli, M. D.; Cobian, J.

    2002-01-01

    IRIS(International Reactor Innovative and Secure) is a novel light water reactor with a modular, integral primary system configuration. This concept, initially developed in response to the first NERI solicitation, is now being pursued by an international consortium of 20 participants from seven countries. IRIS is designed to satisfy the four key requirements for Generation IV systems: enhanced safety, improved economics, proliferation resistance and waste minimization. Its main features are: small-to-medium power (100-335 MWe/module); long life core 5 to 10 years) without shuffling or refueling; optimized maintenance with repair shutdown intervals of a least four years; simplified compact design with the primary vessel housing steam generators, pressurizer and pumps; safety by design where accidents are positively eliminated by design rather than engineering to cope with their consequences; loss of coolant accidents of any size and loss of low accidents are eliminated as major safety concerns; estimated power generation total cost is projected to be competitive with other power options. IRIS is one of four new reactor designs currently under NRC review. Projected schedule calls for design certification by 2008 and being ready for deployment by 2001 or later. This rather short schedule is made possible by the fact that IRIS is based on proven light water technology and new technology development is not required. (Author)

  20. Bilateral acute iris transillumination: Case report

    Directory of Open Access Journals (Sweden)

    Cumali Degirmenci

    2016-04-01

    Full Text Available Bilateral acute iris transillumination (BAIT is a recently defined disease characterized with bilateral acute, severe pigment dispersion of iris and pupil sphincter paralysis. The etiopathogenesis of the disease is unknown, but antibiotics such as moxifloxacin, clarithromycin, viral infections, and fumigation therapies were considered as probable etiologic factors. A 33-year-old female was referred to our clinic for acute iridocyclitis refractory to azathioprine, colchicum and corticosteroid treatments. Ophthalmic examination revealed bilateral pigment dispersion, significant iris transillumination, heavy pigment deposition in iridocorneal angle, and elevated intraocular pressure. Upon systemic evaluation she was found to have bacterial urinary tract infection. BAIT is an important cause of pigment dispersion and clinicians must be vigilant for this condition to avoid unnecessary diagnostic tests and treatment.

  1. Intensity correction method customized for multi-animal abdominal MR imaging with 3 T clinical scanner and multi-array coil

    International Nuclear Information System (INIS)

    Mitsuda, Minoru; Yamaguchi, Masayuki; Nakagami, Ryutaro; Furuta, Toshihiro; Fujii, Hirofumi; Sekine, Norio; Niitsu, Mamoru; Moriyama, Noriyuki

    2013-01-01

    Simultaneous magnetic resonance (MR) imaging of multiple small animals in a single session increases throughput of preclinical imaging experiments. Such imaging using a 3-tesla clinical scanner with multi-array coil requires correction of intensity variation caused by the inhomogeneous sensitivity profile of the coil. We explored a method for correcting intensity that we customized for multi-animal MR imaging, especially abdominal imaging. Our institutional committee for animal experimentation approved the protocol. We acquired high resolution T 1 -, T 2 -, and T 2 * -weighted images and low resolution proton density-weighted images (PDWIs) of 4 rat abdomens simultaneously using a 3T clinical scanner and custom-made multi-array coil. For comparison, we also acquired T 1 -, T 2 -, and T 2 * -weighted volume coil images in the same rats in 4 separate sessions. We used software created in-house to correct intensity variation. We applied thresholding to the PDWIs to produce binary images that displayed only a signal-producing area, calculated multi-array coil sensitivity maps by dividing low-pass filtered PDWIs by low-pass filtered binary images pixel by pixel, and divided uncorrected T 1 -, T 2 -, or T 2 * -weighted images by those maps to obtain intensity-corrected images. We compared tissue contrast among the liver, spinal canal, and muscle between intensity-corrected multi-array coil images and volume coil images. Our intensity correction method performed well for all pulse sequences studied and corrected variation in original multi-array coil images without deteriorating the throughput of animal experiments. Tissue contrasts were comparable between intensity-corrected multi-array coil images and volume coil images. Our intensity correction method customized for multi-animal abdominal MR imaging using a 3T clinical scanner and dedicated multi-array coil could facilitate image interpretation. (author)

  2. Let the IRIS Bloom:Regrowing the integrated risk information system (IRIS) of the U.S. Environmental Protection Agency.

    Science.gov (United States)

    Dourson, Michael L

    2018-05-03

    The Integrated Risk Information System (IRIS) of the U.S. Environmental Protection Agency (EPA) has an important role in protecting public health. Originally it provided a single database listing official risk values equally valid for all Agency offices, and was an important tool for risk assessment communication across EPA. Started in 1986, IRIS achieved full standing in 1990 when it listed 500 risk values, the effort of two senior EPA groups over 5 years of monthly face-to-face meetings, to assess combined risk data from multiple Agency offices. Those groups were disbanded in 1995, and the lack of continuing face-to-face meetings meant that IRIS became no longer EPA's comprehensive database of risk values or their latest evaluations. As a remedy, a work group of the Agency's senior scientists should be re-established to evaluate new risks and to update older ones. Risk values to be reviewed would come from the same EPA offices now developing such information on their own. Still, this senior group would have the final authority on posting a risk value in IRIS, independently of individual EPA offices. This approach could also lay the groundwork for an all-government IRIS database, especially needed as more government Agencies, industries and non-governmental organizations are addressing evolving risk characterizations. Copyright © 2018. Published by Elsevier Inc.

  3. Retrospective Evaluation of Topical Bimatoprost and Iris Pigmentation Change.

    Science.gov (United States)

    Zaleski-Larsen, Lisa A; Ruth, Nadine H; Fabi, Sabrina G

    2017-12-01

    Topical bimatoprost is a topical prostaglandin analog originally used to treat glaucoma and more recently used to cosmetically induce hypertrichosis of the eyelashes. Iris pigmentation change has been noted in the treatment of glaucoma but has not been assessed with the cosmetic periorbital application of bimatoprost. To evaluate for iris pigmentation change with the long-term cosmetic use of topical bimatoprost. A retrospective chart review in a cosmetic dermatology practice of women (N = 50) who consistently purchased topical bimatoprost over an average of 4.59 years was compared with that of age-matched non-bimatoprost patients (N = 50). A blinded evaluator assessed each patient for iris pigmentary change. No iris pigmentation change was noted with the cutaneous application of bimatoprost. The cutaneous application of bimatoprost appears to be safe with minimal risk for iris pigmentation change.

  4. IRIS: Proceeding Towards the Preliminary Design

    International Nuclear Information System (INIS)

    Carelli, M.; Miller, K.; Lombardi, C.; Todreas, N.; Greenspan, E.; Ninokata, H.; Lopez, F.; Cinotti, L.; Collado, J.; Oriolo, F.; Alonso, G.; Morales, M.; Boroughs, R.; Barroso, A.; Ingersoll, D.; Cavlina, N.

    2002-01-01

    The IRIS (International Reactor Innovative and Secure) project has completed the conceptual design phase and is moving towards completion of the preliminary design, scheduled for the end of 2002. Several other papers presented in this conference provide details on major aspects of the IRIS design. The three most innovative features which uniquely characterize IRIS are, in descending order of impact: 1. Safety-by-design, which takes maximum advantage of the integral configuration to eliminate from consideration some accidents, greatly lessen the consequence of other accident scenarios and decrease their probability of occurring; 2. Optimized maintenance, where the interval between maintenance shutdowns is extended to 48 months; and 3. Long core life, of at least four years without shuffling or partial refueling. Regarding feature 1, design and analyses will be supplemented by an extensive testing campaign to verify and demonstrate the performance of the integral components, individually as well as interactive systems. Test planning is being initiated. Test results will be factored into PRA analyses under an overall risk informed regulation approach, which is planned to be used in the IRIS licensing. Pre-application activities with NRC are also scheduled to start in mid 2002. Regarding feature 2, effort is being focused on advanced online diagnostics for the integral components, first of all the steam generators, which are the most critical component; several techniques are being investigated. Finally, a four year long life core design is well underway and some of the IRIS team members are examining higher enrichment, eight to ten year life cores which could be considered for reloads. (authors)

  5. Iridoschisis: high frequency ultrasound imaging. Evidence for a genetic defect?

    Science.gov (United States)

    Danias, J; Aslanides, I M; Eichenbaum, J W; Silverman, R H; Reinstein, D Z; Coleman, D J

    1996-01-01

    AIMS: To elucidate changes in the anatomy of the anterior chamber associated with iridoschisis, a rare form of iris atrophy, and their potential contribution to angle closure glaucoma. METHODS: Both eyes of a 71-year-old woman with bilateral iridoschisis and fibrous dysplasia and her asymptomatic 50-year-old daughter were scanned with a very high frequency (50 MHz) ultrasound system. RESULTS: The symptomatic patient exhibited diffuse changes in the iris stoma with an intact posterior iris pigmented layer in both eyes. These changes were clinically compatible with the lack of iris transillumination defects. Additionally, iris bowing with a resultant narrowing of the angle occurred. The asymptomatic daughter showed discrete, but less severe iris stromal changes. CONCLUSION: This is the first detailed study of high frequency ultrasonic imaging of the iris in iridoschisis. The observed structural changes suggest angle narrowing by forward bowing of the anterior iris stroma may be a mechanism of IOP elevation in this condition. The ultrasonic detection of iris changes in the asymptomatic daughter of the symptomatic patient and the association of iridoschisis with fibrous dysplasia suggest a possible genetic component in the pathogenesis of this condition. Images PMID:9059271

  6. Free-Floating Iris Cyst in a Patient with Recurrent Iritis

    Directory of Open Access Journals (Sweden)

    Joanne M.Y. Teong

    2015-06-01

    Full Text Available Purpose: We describe an unusual clinical finding of a free-floating iris cyst in a patient with recurrent iritis. Method: The clinical finding of a free-floating iris cyst was recorded using slit-lamp photography. Results: A 39-year-old male with a 5-year history of recurrent right iritis was found to have a small mobile iris cyst within his right anterior chamber, first identified 3 years ago. The patient did not experience any discomfort or visual symptoms resulting from the cyst. Conclusion: Surgical removal is not indicated for asymptomatic non-progressive free-floating iris cysts. The significance of a free-floating iris cyst in the setting of recurrent iritis remains unknown.

  7. Using EO-1 Hyperion to Simulate HyspIRI Products for a Coniferous Forest: The Fraction of PAR Absorbed by Chlorophyll (fAPAR(sub chl)) and Leaf Water Content(LWC)

    Science.gov (United States)

    Zhang, Qingyuan; Middleton, Elizabeth M.; Gao, Bo-Cai; Cheng, Yen-Ben

    2012-01-01

    This paper presents development of prototype products for terrestrial ecosystems in preparation for the future imaging spectrometer planned for the Hyperspectral Infrared Imager (HyspIRI) mission. We present a successful demonstration example in a coniferous forest of two product prototypes: fraction of photosynthetically active radiation (PAR) absorbed by chlorophyll of a canopy (fAPARchl) and leaf water content (LWC), for future HyspIRI implementation at 60-m spatial resolution. For this, we used existing 30-m resolution imaging spectrometer data available from the Earth Observing One (EO-1) Hyperion satellite to simulate and prototype the level one radiometrically corrected radiance (L1R) images expected from the HyspIRI visible through shortwave infrared spectrometer. The HyspIRIlike images were atmospherically corrected to obtain surface reflectance and spectrally resampled to produce 60-m reflectance images for wavelength regions that were comparable to all seven of the MODerate resolution Imaging Spectroradiometer (MODIS) land bands. Thus, we developed MODIS-like surface reflectance in seven spectral bands at the HyspIRI-like spatial scale, which was utilized to derive fAPARchl and LWC with a coupled canopy-leaf radiative transfer model (PROSAIL2) for the coniferous forest. With this paper, we provide additional evidence that the fAPARchl product is more realistic in describing the physiologically active canopy than the traditional fAPAR parameter for the whole canopy (fAPARcanopy), and thus, it should replace it in ecosystem process models to reduce uncertainties in terrestrial carbon cycle and ecosystem studies.

  8. Regression Patterns of Iris Melanoma after Palladium-103 (103Pd) Plaque Brachytherapy.

    Science.gov (United States)

    Chaugule, Sonal S; Finger, Paul T

    2017-07-01

    To evaluate the patterns of regression of iris melanoma after treatment with palladium-103 ( 103 Pd) plaque brachytherapy. Retrospective, nonrandomized, interventional case series. Fifty patients with primary malignant melanoma of the iris. Palladium-103 plaque brachytherapy. Changes in tumor size, pigmentation, and vascularity; incidence of iris neovascularization; and radiation-related complications. The mean age in the case series was 61.2±14.9 years. The mean tumor thickness was 1.4±0.6 mm. According to the American Joint Committee on Cancer, eighth edition, staging criteria for iris melanoma, 21 tumors (42%) were T1a, 5 tumors (10%) were T1b, and 24 tumors (48%) were T2a. The tumor was melanotic in 37 cases (74%) and amelanotic in 13 cases (26%); of these, 13 tumors (26%) showed variable pigmentation. After brachytherapy, mean tumor thickness decreased to 0.9±0.2 mm. Pigmentation increased in 32 tumors (64%), decreased in 11 tumors (22%), and was unchanged in 6 tumors (12%). For intrinsic vascularity (n = 19), 12 tumors (63%) showed decrease and 7 tumors (37%) showed complete resolution. Appearance of ectropion uveae showed diminution in 15 tumors (43%); newly present corectopia was observed in 6 patients (12%). On high-frequency ultrasound imaging, of the 42 tumors (84%) with low to moderate internal reflectivity, 30 tumors (60%) showed an increase in internal reflectivity on regression. Iris stromal atrophy was noted in 26 patients (52%), progression or new-onset cataract was noted in 22 patients (44%), neovascular glaucoma was noted in 1 patient (2%), and there were no cases of corneal opacity. There was no clinical evidence (0%) of radiation-induced retinopathy, maculopathy, or optic neuropathy. Mean follow-up in this series was 5.2 years (range, 0.5-17 years). The most common findings related to iris melanoma regression after 103 Pd plaque brachytherapy included decreased intrinsic tumor vascularity, increased tumor pigmentation, and decreased tumor

  9. IRIS Arrays: Observing Wavefields at Multiple Scales and Frequencies

    Science.gov (United States)

    Sumy, D. F.; Woodward, R.; Frassetto, A.

    2014-12-01

    The Incorporated Research Institutions for Seismology (IRIS) provides instruments for creating and operating seismic arrays at a wide range of scales. As an example, for over thirty years the IRIS PASSCAL program has provided instruments to individual Principal Investigators to deploy arrays of all shapes and sizes on every continent. These arrays have ranged from just a few sensors to hundreds or even thousands of sensors, covering areas with dimensions of meters to thousands of kilometers. IRIS also operates arrays directly, such as the USArray Transportable Array (TA) as part of the EarthScope program. Since 2004, the TA has rolled across North America, at any given time spanning a swath of approximately 800 km by 2,500 km, and thus far sampling 2% of the Earth's surface. This achievement includes all of the lower-48 U.S., southernmost Canada, and now parts of Alaska. IRIS has also facilitated specialized arrays in polar environments and on the seafloor. In all cases, the data from these arrays are freely available to the scientific community. As the community of scientists who use IRIS facilities and data look to the future they have identified a clear need for new array capabilities. In particular, as part of its Wavefields Initiative, IRIS is exploring new technologies that can enable large, dense array deployments to record unaliased wavefields at a wide range of frequencies. Large-scale arrays might utilize multiple sensor technologies to best achieve observing objectives and optimize equipment and logistical costs. Improvements in packaging and power systems can provide equipment with reduced size, weight, and power that will reduce logistical constraints for large experiments, and can make a critical difference for deployments in harsh environments or other situations where rapid deployment is required. We will review the range of existing IRIS array capabilities with an overview of previous and current deployments and examples of data and results. We

  10. Iris ultrastructure in patients with synechiae as revealed by in vivo laser scanning confocal microscopy : In vivo iris ultrastructure in patients with Synechiae by Laser Scanning Confocal Microscopy.

    Science.gov (United States)

    Li, Ming; Cheng, Hongbo; Guo, Ping; Zhang, Chun; Tang, Song; Wang, Shusheng

    2016-04-26

    Iris plays important roles in ocular physiology and disease pathogenesis. Currently it is technically challenging to noninvasively examine the human iris ultrastructure in vivo. The purpose of the current study is to reveal human iris ultrastructure in patients with synechiae by using noninvasive in vivo laser scanning confocal microscopy (LSCM). The ultrastructure of iris in thirty one patients, each with synechiae but transparent cornea, was examined by in vivo LSCM. Five characteristic iris ultrastructures was revealed in patients with synechiae by in vivo LSCM, which include: 1. tree trunk-like structure; 2. tree branch/bush-like structure; 3. Fruit-like structure; 4. Epithelioid-like structure; 5. deep structure. Pigment granules can be observed as a loose structure on the top of the arborization structure. In iris-associated diseases with Tyndall's Phenomenon and keratic precipitates, the pigment particles are more likely to fall off from the arborization structure. The ultrastructure of iris in patients with synechiae has been visualized using in vivo LSCM. Five iris ultrastructures can be clearly observed, with some of the structures maybe disease-associated. The fall-off of the pigment particles may cause the Tyndall's Phenomenon positive. In vivo LSCM provides a non-invasive approach to observe the human iris ultrastructure under certain eye disease conditions, which sets up a foundation to visualize certain iris-associated diseases in the future.

  11. BRCA1-IRIS Overexpression Promotes Formation of Aggressive Breast Cancers

    Science.gov (United States)

    Shimizu, Yoshiko; Luk, Hugh; Horio, David; Miron, Penelope; Griswold, Michael; Iglehart, Dirk; Hernandez, Brenda; Killeen, Jeffrey; ElShamy, Wael M.

    2012-01-01

    Introduction Women with HER2+ or triple negative/basal-like (TN/BL) breast cancers succumb to their cancer rapidly due, in part to acquired Herceptin resistance and lack of TN/BL-targeted therapies. BRCA1-IRIS is a recently discovered, 1399 residue, BRCA1 locus alternative product, which while sharing 1365 residues with the full-length product of this tumor suppressor gene, BRCA1/p220, it has oncoprotein-like properties. Here, we examine whether BRCA1-IRIS is a valuable treatment target for HER2+ and/or TN/BL tumors. Methodology/Principal Findings Immunohistochemical staining of large cohort of human breast tumor samples using new monoclonal anti-BRCA1-IRIS antibody, followed by correlation of BRCA1-IRIS expression with that of AKT1, AKT2, p-AKT, survivin and BRCA1/p220, tumor status and age at diagnosis. Generation of subcutaneous tumors in SCID mice using human mammary epithelial (HME) cells overexpressing TERT/LT/BRCA1-IRIS, followed by comparing AKT, survivin, and BRCA1/p220 expression, tumor status and aggressiveness in these tumors to that in tumors developed using TERT/LT/RasV12-overexpressing HME cells. Induction of primary and invasive rat mammary tumors using the carcinogen N-methyl-N-nitrosourea (NMU), followed by analysis of rat BRCA1-IRIS and ERα mRNA levels in these tumors. High BRCA1-IRIS expression was detected in the majority of human breast tumors analyzed, which was positively correlated with that of AKT1-, AKT2-, p-AKT-, survivin, but negatively with BRCA1/p220 expression. BRCA1-IRIS-positivity induced high-grade, early onset and metastatic HER2+ or TN/BL tumors. TERT/LT/BRCA1-IRIS overexpressing HME cells formed invasive subcutaneous tumors that express high AKT1, AKT2, p-AKT and vimentin, but no CK19, p63 or BRCA1/p220. NMU-induced primary and invasive rat breast cancers expressed high levels of rat BRCA1-IRIS mRNA but low levels of rat ERα mRNA. Conclusion/Significance BRCA1-IRIS overexpression triggers aggressive breast tumor formation

  12. Developmental origin of the posterior pigmented epithelium of iris.

    Science.gov (United States)

    Wang, Xiaobing; Xiong, Kai; Lu, Lei; Gu, Dandan; Wang, Songtao; Chen, Jing; Xiao, Honglei; Zhou, Guomin

    2015-03-01

    Iris epithelium is a double-layered pigmented cuboidal epithelium. According to the current model, the neural retina and the posterior iris pigment epithelium (IPE) are derived from the inner wall of the optic cup, while the retinal pigment epithelium (RPE) and the anterior IPE are derived from the outer wall of the optic cup during development. Our current study shows evidence, contradicting this model of fetal iris development. We demonstrate that human fetal iris expression patterns of Otx2 and Mitf transcription factors are similar, while the expressions of Otx2 and Sox2 are complementary. Furthermore, IPE and RPE exhibit identical morphologic development during the early embryonic period. Our results suggest that the outer layer of the optic cup forms two layers of the iris epithelium, and the posterior IPE is the inward-curling anterior rim of the outer layer of the optic cup. These findings provide a reasonable explanation of how IPE cells can be used as an appropriate substitute for RPE cells.

  13. The design and safety features of the IRIS reactor

    International Nuclear Information System (INIS)

    Carelli, Mario D.; Conway, L.E.; Oriani, L.; Petrovic, B.; Lombardi, C.V.; Ricotti, M.E.; Barroso, A.C.O.; Collado, J.M.; Cinotti, L.; Todreas, N.E.; Grgic, D.; Moraes, M.M.; Boroughs, R.D.; Ninokata, H.; Ingersoll, D.T.; Oriolo, F.

    2004-01-01

    Salient features of the International Reactor Innovative and Secure (IRIS) are presented here. IRIS, an integral, modular, medium size (335 MWe) PWR, has been under development since the turn of the century by an international consortium led by Westinghouse and including over 20 organizations from nine countries. Described here are the features of the integral design which includes steam generators, pumps and pressurizer inside the vessel, together with the core, control rods, and neutron reflector/shield. A brief summary is provided of the IRIS approach to extended maintenance over a 48-month schedule. The unique IRIS safety-by-design approach is discussed, which, by eliminating accidents, at the design stage, or decreasing their consequences/probabilities when outright elimination is not possible, provides a very powerful first level of defense in depth. The safety-by-design allows a significant reduction and simplification of the passive safety systems, which are presented here, together with an assessment of the IRIS response to transients and postulated accidents

  14. Internet Renewable energy Information System (IRIS)

    DEFF Research Database (Denmark)

    Bäurle, Britta; Nielsen, Vilhjalmur; Ménard, Lionel

    1999-01-01

    Even though the Internet is now a widely accessible data source, the unorganised flood of information makes a specific request e.g. for renewable energy products inefficient. In addition, existing databases on renewable energies are often old and incomplete. The objective of IRIS has been...... to organise and retrieve renewable energy product information on the Internet instead of collecting it manually. Updating coincides with the self interestself-interest of manufacturers to present their latest renewable energy products on their own HTML documents. IRIS is based on a set of powerful tools...... and intends to find, extract, collect and index HTML documents with standardised META tags that are widely spread across web servers on the Internet. This paper presents the structure of IRIS, the software tools, and gives one example of how to categorise and prepare web-sites with product information...

  15. A patient with multiple iris | Asselman | Southern African Journal of ...

    African Journals Online (AJOL)

    IRIS results from a pathological inflammatory response to pre-existing infective, host or other antigens, alive or dead, causing clinical deterioration in HIV-infected patients after initiating ART.1 A case definition for IRIS is shown in Table I. The most common forms of IRIS described occur in association with mycobacterial and ...

  16. IRIS PRA preliminary results and future direction

    International Nuclear Information System (INIS)

    Finnicum, D.J.; Kling, C.L.; Carelli, M.D.

    2004-01-01

    Westinghouse is currently conducting the pre-application licensing of the International Reactor Innovative and Secure (IRIS) on behalf of the IRIS Consortium. One of the key aspects of the IRIS design is the concept of safety-by-design. The PRA (Probabilistic Risk Analysis) is being used as an integral part of the design process. As part of this effort, a PRA of the initial design was generated to address 2 key areas. First, the IRIS PRA supported the evaluation of IRIS design issues by providing a solid risk basis for design and analyses required for the pre-licensing evaluation of the IRIS design. The PRA provides the tool for quantifying the benefit of the safety-by-design approach. Second, the current PRA task is beginning the preparation of the more complete PRA analyses and documentation eventually required for Design Certification. One of the key risk-related goals for IRIS is to reduce the EPZ (Emergency Protection Zone) to within the exclusion area by demonstrating that the off-site doses are consistent with the US Protective Action Guidelines (PAGs) for initiation of emergency response so that the required protective actions would be limited to the exclusion area. The results of the preliminary PRA indicated a core damage frequency of 1.2 E-08 for internal initiators. This is a very good result but much work is needed to meet the ambitious goal of no emergency response. The next phase of the PRA analyses will involve a two-fold expansion of the PRA. First, as the design and analyses approach a greater level of detail, the assumptions used for the initial PRA will be reviewed and the models will be revised as needed to reflect the improved knowledge of the system design and performance. Furthermore, as the full plant design advances, the PRA will be expanded to incorporate risk associated with external challenges such as seismic and fire, and to address low power and shutdowns modes of operation. As with the initial work, the PRA will serve as a tool to

  17. Ekspert i undervisning - IRIS Connect

    DEFF Research Database (Denmark)

    Wullum, Annemette Heine; Eriksen, Frits Hedegaard

    Ekspert i undervisning – IRIS Connect Credoet bag de seneste års mange læreruddannelsesreformer har været, at flere og dybere kundskaber vil styrke de studerendes forudsætninger for at løse opgaverne i pædagogisk praksis. Et forhold, som bliver overset i forbindelse med uddannelsesreformerne, er...... praksis, og hvad ”effektiv” undervisning er. Hovedantagelserne bag projektet er, at de studerendes personbundne kundskaber kan synliggøres, at deres lægmandsopfattelser af, hvad ”effektiv” undervisning er, kan udfordres gennem analyser og drøftelser, og at brugen af IRIS Connects dataindsamlings- og...

  18. Report printer (COBOL IRIS 50)

    International Nuclear Information System (INIS)

    Paul, Daniele

    1973-10-01

    The research thesis reports a detailed study of the Report Writer of the COBOL language in order to integrate it into the IRIS 50 COBOL compiler. In order to use existing compiler processing, the author developed a simulation of the Report Writer by using Cobol statements generated in the declarative part of the Division procedure. After a brief presentation of the IRIS 50 computer, the author presents the general plan of the compiler with modifications and adjunctions exclusively due to the Report Writer. The next part addresses the practical implementation and the problems met and solved during this implementation

  19. Qualitative Assessment of Ultrasound Biomicroscopic Images Using Standard Photographs: The Liwan Eye Study

    Science.gov (United States)

    Jiang, Yuzhen; Huang, Wenyong; Huang, Qunxiao; Zhang, Jian; Foster, Paul J.

    2010-01-01

    Objective. To classify anatomic features related to anterior chamber angles by a qualitative assessment system based on ultrasound biomicroscopy (UBM) images. Methods. Cases of primary angle-closure suspect (PACS), defined by pigmented trabecular meshwork that is not visible in two or more quadrants on static gonioscopy (cases) and systematically selected subjects (1 of every 10) who did not meet this criterion (controls) were enrolled during a population-based survey in Guangzhou, China. All subjects underwent UBM examination. A set of standard UBM images was used to qualitatively classify anatomic features related to the angle configuration, including iris thickness, iris convexity, iris angulation, ciliary body size, and ciliary process position. All analysis was conducted on right eye images. Results. Based on the qualitative grades, the difference in overall iris thickness between gonioscopically narrow eyes (n = 117) and control eyes (n = 57) was not statistically significant. The peripheral one third of the iris tended to be thicker in all quadrants of the PACS eyes, although the difference was statistically significant only in the superior quadrant (P = 0.008). No significant differences were found in the qualitative classifications of iris insertion, iris angulation, ciliary body size, and ciliary process position. The findings were similar when compared with the control group of eyes with wide angles in all quadrants. Conclusions. Basal iris thickness seems to be more relevant to narrow angle configuration than to overall iris thickness. Otherwise, the anterior rotation and size of the ciliary body, the iris insertion, and the overall iris thickness are comparable in narrow- and wide-angle eyes. PMID:19834039

  20. IRIS: A SIGNIFICANT ELEMENT OF THE MEDITERRANEAN LANDSCAPE

    Directory of Open Access Journals (Sweden)

    A. UBRIZSY SAVOIA

    2000-01-01

    Full Text Available The Southern European species of Iris growing in dry, rocky places, stony ground, terra rossa, sandy, basalt and/or calcareous hills, maquis and coastal rocky slopes, are a neglected bioplasm resource of the Mediterranean landscape. These species have traditional uses and cultural significance and have inspired artists. Both natural and naturalised ornamental Iris species may help to improve and maintain the Mediterranean landscape by avoiding land erosion, fixing dunes and preserving coastal zones. These Iris species are a significant component of Mediterranean floristic diversity. Their conservation and use in traditional Mediterranean landscape gardening are emphasised.

  1. IRIS: A SIGNIFICANT ELEMENT OF THE MEDITERRANEAN LANDSCAPE

    Directory of Open Access Journals (Sweden)

    S. PIGNATTI

    2000-04-01

    Full Text Available The Southern European species of Iris growing in dry, rocky places, stony ground, terra rossa, sandy, basalt and/or calcareous hills, maquis and coastal rocky slopes, are a neglected bioplasm resource of the Mediterranean landscape. These species have traditional uses and cultural significance and have inspired artists. Both natural and naturalised ornamental Iris species may help to improve and maintain the Mediterranean landscape by avoiding land erosion, fixing dunes and preserving coastal zones. These Iris species are a significant component of Mediterranean floristic diversity. Their conservation and use in traditional Mediterranean landscape gardening are emphasised.

  2. Some measurement possibilities for the improvement of IRI

    International Nuclear Information System (INIS)

    Serafimov, K.B.

    1984-01-01

    Some methodological assumptions behind the development of improved measurements for use in the International Reference Ionosphere (IRI) are presented. Attention is given to improving the IRI-representation of electron density in the D-region by comparing data from vertical rocket soundings and absorption measurements on multifrequencies ionosondes; by the application of absorption measurements for the specification of density profile structure; and by the use of combined rocket and ground-based measurements. The methodological possibilities, for improving the IRI-distribution of electron densities in the bottomside and topside ionosphere, and for the specification of Te(h) profiles are also discussed

  3. Iris structure and minor physical anomalies in schizophrenia.

    Science.gov (United States)

    Trixler, Dániel; Tényi, Tamás

    2017-10-01

    This study compared five human iris characteristics and minor physical anomalies (MPAs) between patients with schizophrenia (n = 32) and controls (n = 31). Correlations between iris characteristics and MPAs were expected, due to their same ectodermic origin. Iris macro photos were taken and quantified in five categories mentioned before. MPAs were also examined in both groups. Our results show significant differences in the frequency of pigment dots of the iris and total number of MPAs between groups. Other significant differences were found in the extension of concentric furrows, as they were more common in healthy subjects, while Wolfflin nodules occurred significantly more often in patients with schizophrenia. Expected difference in Fuch's crypts could not be observed between groups. Light eye color was positively correlated to pigment dots and Wolfflin nodules, and negatively correlated with concentric furrows. Dark eye color showed positive correlation with concentric furrows, and negative correlation with pigment dots and concentric furrows. A gender effect could also been observed: male individuals showed moderate positive correlations between pigment dots and total MPAs frequency, while this couldn't be observed in the female group. Our findings suggest possible connections between iris characteristics and MPAs, where males are more prone to deviations. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Investigating the service brand: A customer value perspective

    Directory of Open Access Journals (Sweden)

    Leyla Heydari

    2014-04-01

    Full Text Available This paper examines the effect of the service brand on the customer value–loyalty process. The study includes the traditional effect of brand image plus three additional influences, which reflects the broader service perspective including company image, employee trust, and company trust. Using survey data of a sample of 385 bank customers, the analysis indicates there is a direct influence of some of the perspectives of the brand on customers' perceptions of value. The results indicate that brand image, organization image, trust to firm influence positively on quality of services. In addition, brand image, organization image, quality of services and trust to firm influence on customer’s perspective where quality of services maintains the lowest impact and corporate image has the highest impact on customer’s perspective.

  5. Use of iris recognition camera technology for the quantification of corneal opacification in mucopolysaccharidoses.

    Science.gov (United States)

    Aslam, Tariq Mehmood; Shakir, Savana; Wong, James; Au, Leon; Ashworth, Jane

    2012-12-01

    Mucopolysaccharidoses (MPS) can cause corneal opacification that is currently difficult to objectively quantify. With newer treatments for MPS comes an increased need for a more objective, valid and reliable index of disease severity for clinical and research use. Clinical evaluation by slit lamp is very subjective and techniques based on colour photography are difficult to standardise. In this article the authors present evidence for the utility of dedicated image analysis algorithms applied to images obtained by a highly sophisticated iris recognition camera that is small, manoeuvrable and adapted to achieve rapid, reliable and standardised objective imaging in a wide variety of patients while minimising artefactual interference in image quality.

  6. Single application on iris localization technology in excimer laser for astigmatism

    Directory of Open Access Journals (Sweden)

    Jun-Hua Hao

    2014-06-01

    Full Text Available AIM:To discuss the single application on iris localization technology in excimer laser for the treatment of astigmatism. METHODS:Totally 203 cases(406 eyesof laser in situ keratomileusis(LASIKin the treatment of compound myopic astigmatism patients were operated from November 2011 to November 2012 in our hospital. They were divided into two groups. One was observation group using iris localization and the other was control group using routine operation. Patients in the observation group of 100 cases(200 eyes, aged 18-43 years old, spherical diopter was -1.25 to -8.75D, astigmatism was -1.0 to -3.25D. In control group, 103 patients(206 eyes, aged 19-44 years old, spherical diopter was -1.75-9.50D, astigmatism was -1.0 to -3.25D. The patients in the observation group before the application of WaveScan aberrometer check for iris image, spherical lens, cylindrical lens and astigmatism axis data operation, only single application of iris location, without using wavefront aberration guided technology, laser cutting patterns for conventional LASIK model, spherical, cylindrical mirror and astigmatism axis data source to preoperative wavefront aberration results. The control group received routine LASIK. It was applicated comprehensive optometry optometry respectively to examine astigmatism and axial, based on the computer analysis during the preoperative, 1wk after the operation, and 6mo. Analysis of using SPSS 17 statistical software, it was independent-sample t test between the two groups of residual astigmatism and astigmatism axis. RESULTS:Postoperative residual astigmatism, the observation group was significantly better than the control group. Astigmatism axial measurement after operation, the observation group was significantly less than that of the control group. Postoperative visual acuity at 6mo, the observation group was better than that of the control group. The difference was statistically significant. CONCLUSION: For patients who cannot

  7. IRIS Toxicological Review of Trichloroethylene (TCE) ...

    Science.gov (United States)

    EPA is conducting a peer review and public comment of the scientific basis supporting the human health hazard and dose-response assessment of Trichloroethylene (TCE) that when finalized will appear on the Integrated Risk Information System (IRIS) database. The purpose of this Toxicological Review is to provide scientific support and rationale for the hazard and dose-response assessment in IRIS pertaining to chronic exposure to trichloroethylene. It is not intended to be a comprehensive treatise on the chemical or toxicological nature of trichloroethylene.

  8. Anterior Lens Capsule and Iris Thicknesses in Pseudoexfoliation Syndrome.

    Science.gov (United States)

    Batur, Muhammed; Seven, Erbil; Tekin, Serek; Yasar, Tekin

    2017-11-01

    The aim of this study was to evaluate anatomic properties of the lens capsule and iris by anterior segment optical coherence tomography (AS-OCT) in patients with pseudoexfoliation (PEX). This prospective study included 62 eyes of 62 patients with PEX syndrome and 43 eyes of 43 age- and gender-matched controls. All subjects underwent full ophthalmologic examinations including AS-OCT. Pupillary diameter, midperipheral stromal iris thickness, central and temporal lens capsule thicknesses, and peripheral pseudoexfoliation material thickness on the anterior lens capsule surface were measured and recorded. Mean age was 66.8 ± 9.3 years in the PEX group and 65.5 ± 8.9 years in the control group (p = 0.44). The PEX group consisted of 62 patients: 38 men (61.3%) and 24 women (38.7%); the control group included 43 subjects: 25 men (58.1%) and 18 women (41.9%). Pupillary diameter after pharmacologic mydriasis was 21% smaller in the PEX group than controls. Mean midperipheral iris thickness was 36 ± 7.2 μm (7.8%) thinner in the PEX group than that of control group (p = 0.047). The central anterior capsule was a mean of 3.40 ± 0.51 μm (18%) thicker in the PEX group compared to the control group (p = 0.0001). The temporal anterior lens capsule was a mean of 0.17 ± 0.15 μm thicker in the PEX group compared to the control group (p = 0.81). With high-resolution OCT imaging, it has become possible to evaluate the anterior lens capsule without histologic examination and demonstrate that it is thicker than normal in PEX patients.

  9. The IRIS consortium: international cooperation in advanced reactor development

    International Nuclear Information System (INIS)

    Carelli, M.; Petrovic, B.; Miller, K.; Lombardi, C.; Ricotti, M.E.

    2005-01-01

    Besides its many outstanding technical innovations in the design and safety, the most innovative feature of the International Reactor Innovative and Secure (IRIS), is perhaps the international cooperation which carries on its development. IRIS is designed by an international consortium which currently numbers 21 organizations from ten countries across four continents. It includes reactor, fuel and fuel cycle vendors, component manufacturers, laboratories, academia, architect engineers and power producers. The defining organizational characteristics of IRIS is that while Westinghouse has overall lead and responsibility, this lead is of the type of 'primus inter pares' (first among equals) rather than the traditional owner versus suppliers/contractors relationship. All members of the IRIS consortium contribute and expect to have a return, should IRIS be successfully deployed, commensurate to their investment. The nature of such return will be tailored to the type of each organization, because it will of course be of a different nature for say a component manufacturer, university, or architect engineer. One fundamental tenet of the consortium is that all members, regardless of their amount of contribution, have equal access to all information developed within the project. Technical work is thus being coordinated by integrated subgroups and the whole team meets twice a year to perform an overall review of the work, discuss policy and strategy and plan future activities. Personnel from consortium members have performed internships, mostly at Westinghouse locations in Pittsburgh, Pennsylvania, and Windsor, Connecticut, but also at other members, as it has been the case for several graduate students. In fact, more than one hundred students at the various universities have been working on IRIS, most of them conducting graduate theses at the master or doctoral level. The IRIS experience has proved very helpful to the students in successfully landing their employment choice

  10. [Evaluation of Iris Morphology Viewed through Stromal Edematous Corneas by Infrared Camera].

    Science.gov (United States)

    Kobayashi, Masaaki; Morishige, Naoyuki; Morita, Yukiko; Yamada, Naoyuki; Kobayashi, Motomi; Sonoda, Koh-Hei

    2016-02-01

    We reported that the application of infrared camera enables us to observe iris morphology in Peters' anomaly through edematous corneas. To observe the iris morphology in bullous keratopathy or failure grafts with an infrared camera. Eleven bullous keratopathy or failure grafts subjects (6 men and 5 women, mean age ± SD; 72.7 ± 13.0 years old) were enrolled in this study. The iris morphology was observed by applying visible light mode and near infrared light mode of infrared camera (MeibomPen). The detectability of pupil shapes, iris patterns and presence of iridectomy was evaluated. Infrared mode observation enabled us to detect the pupil shapes in 11 out of 11 cases, iris patterns in 3 out of 11 cases, and presence of iridetomy in 9 out of 11 cases although visible light mode observation could not detect any iris morphological changes. Applying infrared optics was valuable for observation of the iris morphology through stromal edematous corneas.

  11. Optimal Face-Iris Multimodal Fusion Scheme

    Directory of Open Access Journals (Sweden)

    Omid Sharifi

    2016-06-01

    Full Text Available Multimodal biometric systems are considered a way to minimize the limitations raised by single traits. This paper proposes new schemes based on score level, feature level and decision level fusion to efficiently fuse face and iris modalities. Log-Gabor transformation is applied as the feature extraction method on face and iris modalities. At each level of fusion, different schemes are proposed to improve the recognition performance and, finally, a combination of schemes at different fusion levels constructs an optimized and robust scheme. In this study, CASIA Iris Distance database is used to examine the robustness of all unimodal and multimodal schemes. In addition, Backtracking Search Algorithm (BSA, a novel population-based iterative evolutionary algorithm, is applied to improve the recognition accuracy of schemes by reducing the number of features and selecting the optimized weights for feature level and score level fusion, respectively. Experimental results on verification rates demonstrate a significant improvement of proposed fusion schemes over unimodal and multimodal fusion methods.

  12. Combining GPS measurements and IRI model predictions

    International Nuclear Information System (INIS)

    Hernandez-Pajares, M.; Juan, J.M.; Sanz, J.; Bilitza, D.

    2002-01-01

    The free electrons distributed in the ionosphere (between one hundred and thousands of km in height) produce a frequency-dependent effect on Global Positioning System (GPS) signals: a delay in the pseudo-orange and an advance in the carrier phase. These effects are proportional to the columnar electron density between the satellite and receiver, i.e. the integrated electron density along the ray path. Global ionospheric TEC (total electron content) maps can be obtained with GPS data from a network of ground IGS (international GPS service) reference stations with an accuracy of few TEC units. The comparison with the TOPEX TEC, mainly measured over the oceans far from the IGS stations, shows a mean bias and standard deviation of about 2 and 5 TECUs respectively. The discrepancies between the STEC predictions and the observed values show an RMS typically below 5 TECUs (which also includes the alignment code noise). he existence of a growing database 2-hourly global TEC maps and with resolution of 5x2.5 degrees in longitude and latitude can be used to improve the IRI prediction capability of the TEC. When the IRI predictions and the GPS estimations are compared for a three month period around the Solar Maximum, they are in good agreement for middle latitudes. An over-determination of IRI TEC has been found at the extreme latitudes, the IRI predictions being, typically two times higher than the GPS estimations. Finally, local fits of the IRI model can be done by tuning the SSN from STEC GPS observations

  13. Information fusion in personal biometric authentication based on the iris pattern

    International Nuclear Information System (INIS)

    Wang, Fenghua; Han, Jiuqiang

    2009-01-01

    Information fusion in biometrics has received considerable attention. This paper focuses on the application of information fusion techniques in iris recognition. To improve the reliability and accuracy of personal identification based on the iris pattern, this paper proposes the schemes of multialgorithmic fusion and multiinstance fusion. Multialgorithmic fusion integrates the improved phase algorithm and the DCT-based algorithm, and multiinstance fusion combines information from the left iris and the right iris of an individual. Both multialgorithmic fusion and multiinstance fusion are carried out at the matching score level and the support vector machine (SVM)-based fusion rule is utilized to generate fused scores for final decision. The experimental results on the noisy iris database UBIRIS demonstrate that the proposed fusion schemes can perform better than the single recognition systems, and further prove that information fusion techniques are feasible and effective to improve the accuracy and robustness of iris recognition especially under noisy conditions

  14. Feature and score fusion based multiple classifier selection for iris recognition.

    Science.gov (United States)

    Islam, Md Rabiul

    2014-01-01

    The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al.

  15. Feature and Score Fusion Based Multiple Classifier Selection for Iris Recognition

    Directory of Open Access Journals (Sweden)

    Md. Rabiul Islam

    2014-01-01

    Full Text Available The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al.

  16. Diffraction analysis of customized illumination technique

    Science.gov (United States)

    Lim, Chang-Moon; Kim, Seo-Min; Eom, Tae-Seung; Moon, Seung Chan; Shin, Ki S.

    2004-05-01

    Various enhancement techniques such as alternating PSM, chrome-less phase lithography, double exposure, etc. have been considered as driving forces to lead the production k1 factor towards below 0.35. Among them, a layer specific optimization of illumination mode, so-called customized illumination technique receives deep attentions from lithographers recently. A new approach for illumination customization based on diffraction spectrum analysis is suggested in this paper. Illumination pupil is divided into various diffraction domains by comparing the similarity of the confined diffraction spectrum. Singular imaging property of individual diffraction domain makes it easier to build and understand the customized illumination shape. By comparing the goodness of image in each domain, it was possible to achieve the customized shape of illumination. With the help from this technique, it was found that the layout change would not gives the change in the shape of customized illumination mode.

  17. An investigation on the effects of brand equity, trust, image and customer satisfaction on regular insurance firm customers’ loyalty

    Directory of Open Access Journals (Sweden)

    Hamid Reza Saeednia

    2014-03-01

    Full Text Available Brand plays essential role on the success of most organizations and it has been considered as organizational assets. Therefore, brand management is important in today’s structure of organizations. A good brand helps gain new customer and future preferences, which leads to customer retention. Brand loyalty is one of the most important components of brand management. It can raise firm’s market share and it has close relationship with firm’s return of investment and profits. This research tries to answer this question and finds out more about the relationship between customer satisfaction, trust, brand equity, brand image and customer loyalty. The study uses a sample of 384 regular customers who use insurance services in Iran. Using Pearson correlation ratio as well as structural equation modeling, the study has detected positive and meaningful relationship between brand equity and other factors such as customer satisfaction, trust, etc.

  18. Quantitative study of the microvasculature and its endothelial cells in the porcine iris.

    Science.gov (United States)

    Yang, Hongfang; Yu, Paula K; Cringle, Stephen J; Sun, Xinghuai; Yu, Dao-Yi

    2015-03-01

    The roles of the iris microvasculature have been increasingly recognised in the pathogenesis of glaucoma and cataract; however limited information exists regarding the iris microvasculature and its endothelium. This study quantitatively assessed the iris microvascular network and its endothelium using intra-luminal micro-perfusion, fixation, and staining of the porcine iris. The temporal long posterior ciliary artery of 11 isolated porcine eyes was cannulated, perfusion-fixed and labelled using silver nitrate. The iris microvasculature was studied for its distribution, orders and endothelial morphometrics. The density of three layers of microvasculature was measured. Endothelial cell length and width were measured for each vessel order. The iris has an unusual vascular distribution which consisted of abundant large vessels in the middle of the iris stroma, branching over a relatively short distance to the microvasculature located in the superficial and deep stroma as well as the pupil edge. The average vascular density of the middle, superficial, and deep layers were 38.9 ± 1.93%, 10.9 ± 1.61% and 8.0 ± 0.79% respectively. Multiple orders of iris vessels (capillary, 6 orders of arteries, and 4 orders of veins) with relatively large capillary and input arteries (319.5 ± 25.6 μm) were found. Significant heterogeneity of vascular diameter and shape of the endothelia was revealed in different orders of the iris vasculature. Detailed information of topography and endothelium of the iris microvasculature combined with unique structural features of the iris may help us to further understand the physiological and pathogenic roles of the iris in relevant ocular diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors.

    Science.gov (United States)

    Berbeco, Ross I; Jiang, Steve B; Sharp, Gregory C; Chen, George T; Mostafavi, Hassan; Shirato, Hiroki

    2004-01-21

    The design of an integrated radiotherapy imaging system (IRIS), consisting of gantry mounted diagnostic (kV) x-ray tubes and fast read-out flat-panel amorphous-silicon detectors, has been studied. The system is meant to be capable of three main functions: radiographs for three-dimensional (3D) patient set-up, cone-beam CT and real-time tumour/marker tracking. The goal of the current study is to determine whether one source/panel pair is sufficient for real-time tumour/marker tracking and, if two are needed, the optimal position of each relative to other components and the isocentre. A single gantry-mounted source/imager pair is certainly capable of the first two of the three functions listed above and may also be useful for the third, if combined with prior knowledge of the target's trajectory. This would be necessary because only motion in two dimensions is visible with a single imager/source system. However, with previously collected information about the trajectory, the third coordinate may be derived from the other two with sufficient accuracy to facilitate tracking. This deduction of the third coordinate can only be made if the 3D tumour/marker trajectory is consistent from fraction to fraction. The feasibility of tumour tracking with one source/imager pair has been theoretically examined here using measured lung marker trajectory data for seven patients from multiple treatment fractions. The patients' selection criteria include minimum mean amplitudes of the tumour motions greater than 1 cm peak-to-peak. The marker trajectory for each patient was modelled using the first fraction data. Then for the rest of the data, marker positions were derived from the imager projections at various gantry angles and compared with the measured tumour positions. Our results show that, due to the three dimensionality and irregular trajectory characteristics of tumour motion, on a fraction-to-fraction basis, a 'monoscopic' system (single source/imager) is inadequate for

  20. Easy access to geophysical data sets at the IRIS Data Management Center

    Science.gov (United States)

    Trabant, C.; Ahern, T.; Suleiman, Y.; Karstens, R.; Weertman, B.

    2012-04-01

    At the IRIS Data Management Center (DMC) we primarily manage seismological data but also have other geophysical data sets for related fields including atmospheric pressure and gravity measurements and higher level data products derived from raw data. With a few exceptions all data managed by the IRIS DMC are openly available and we serve an international research audience. These data are available via a number of different mechanisms from batch requests submitted through email, web interfaces, near real time streams and more recently web services. Our initial suite of web services offer access to almost all of the raw data and associated metadata managed at the DMC. In addition, we offer services that apply processing to the data before it is sent to the user. Web service technologies are ubiquitous with support available in nearly every programming language and operating system. By their nature web services are programmatic interfaces, but by choosing a simple subset of web service methods we make our data available to a very broad user base. These interfaces will be usable by professional developers as well as non-programmers. Whenever possible we chose open and recognized standards. The data returned to the user is in a variety of formats depending on type, including FDSN SEED, QuakeML, StationXML, ASCII, PNG images and in some cases where no appropriate standard could be found a customized XML format. To promote easy access to seismological data for all researchers we are coordinating with international partners to define web service interfaces standards. Additionally we are working with key partners in Europe to complete the initial implementation of these services. Once a standard has been adopted and implemented at multiple data centers researchers will be able to use the same request tools to access data across multiple data centers. The web services that apply on-demand processing to requested data include the capability to apply instrument corrections and

  1. Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    International Nuclear Information System (INIS)

    Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U.J.; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J.R.; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Bonomo, Lorenzo; Schoenberg, Stefan O.; Apfaltrer, Paul

    2013-01-01

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. (orig.)

  2. Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Tricarico, Francesco [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Catholic University of the Sacred Heart, ' ' A. Gemelli' ' Hospital, Department of Bioimaging and Radiological Sciences, Rome (Italy); Hlavacek, Anthony M. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Children' s Hospital, Medical University of South Carolina, Division of Pediatric Cardiology, Charleston, SC (United States); Schoepf, U.J. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Children' s Hospital, Medical University of South Carolina, Division of Pediatric Cardiology, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Ebersberger, Ullrich [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Heart Centre Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Nance, John W. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Vliegenthart, Rozemarijn [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); University Medical Centre Groningen/University of Groningen, Centre for Medical Imaging - North East Netherlands, Department of Radiology, Groningen (Netherlands); Cho, Young Jun [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Konyang University School of Medicine, Department of Radiology, Daejeon (Korea, Republic of); Spears, J.R. [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); Secchi, Francesco [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Milan School of Medicine IRCCS Policlinico San Donato, Department of Medical and Surgical Sciences, Radiology Unit, Milan (Italy); Savino, Giancarlo; Marano, Riccardo; Bonomo, Lorenzo [Catholic University of the Sacred Heart, ' ' A. Gemelli' ' Hospital, Department of Bioimaging and Radiological Sciences, Rome (Italy); Schoenberg, Stefan O. [University Medical Centre Mannheim, Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Apfaltrer, Paul [Medical University of South Carolina, Ashley River Tower, Department of Radiology and Radiological Science, Charleston, SC (United States); University Medical Centre Mannheim, Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany)

    2013-05-15

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. (orig.)

  3. IRIS design overview and status update

    International Nuclear Information System (INIS)

    Carelli, M.D.; Petrovic, B.; Conway, L.E.; Oriani, L.; Kling, C.L.; Miller, K.; Lombardi, C.V.; Ricotti, M.E.; Barroso, A.C.O.; Collado, J.M.; Cinotti, L.; Storai, S.; Berra, F.; Todreas, N.E.; Ninokata, H.; Cavlina, N.; Grgic, D.; Oriolo, F.; Moraes, M.M.; Frederico, C.; Henning, F.; Griffith, W.; Love, J.; Ingersoll, D.T.; Wood, R.; Alonso, G.; Kodochigov, N.; Polunichev, V.; Augutis, J.; Alzbutas, R.; Boroughs, R.D.; Naviglio, A.; Panella, B.

    2005-01-01

    The International Reactor Innovative and Secure (IRIS) is an advanced, integral, light-water cooled reactor of medium generating capacity (1000 MWt, or ∼335 MWe), geared at near term deployment (2012- 2015). It has been under development since the turn of the century by an international consortium--led by Westinghouse--that includes 21 organizations from 10 countries, and it is currently in the pre-application licensing process with the U.S. Nuclear Regulatory Commission (NRC). This paper describes its integral design (i.e., steam generators, pumps, pressurizer and control rod drive mechanisms are all included inside the reactor vessel, together with the core, control rods, and neutron reflector/shield) and discusses the unique ('safety-by-design') TM IRIS philosophy. This approach, by eliminating accidents at the design stage, or decreasing their consequences and probabilities when outright elimination is not possible, provides a very powerful first level of defense in depth. The ('safety by- design') TM allows a significant reduction and simplification of the passive safety systems, which not only improves safety but simultaneously reduces the overall cost. Moreover, it supports licensing the power plant without the need for off-site emergency response planning--an objective which is part of the pre-application with NRC and is also pursued within an international research project coordinated by the International Atomic Energy Agency (IAEA). This would allow IRIS to be treated as any other industrial facility, located closer to population centers, and enable its effective dual-purpose use for electricity production and co-generation (district heating, desalination, industrial steam). The modular IRIS--with each module rated at ∼335 MWe--is an ideal size for developing countries as it allows to easily introducing single modules in regions only requiring a few hundred MWs, or a moderate amount of power on limited electric grids. IRIS can be also deployed in

  4. International Roughness Index (IRI) measurement using Hilbert-Huang transform

    Science.gov (United States)

    Zhang, Wenjin; Wang, Ming L.

    2018-03-01

    International Roughness Index (IRI) is an important metric to measure condition of roadways. This index is usually used to justify the maintenance priority and scheduling for roadways. Various inspection methods and algorithms are used to assess this index through the use of road profiles. This study proposes to calculate IRI values using Hilbert-Huang Transform (HHT) algorithm. In particular, road profile data is provided using surface radar attached to a vehicle driving at highway speed. Hilbert-Huang transform (HHT) is used in this study because of its superior properties for nonstationary and nonlinear data. Empirical mode decomposition (EMD) processes the raw data into a set of intrinsic mode functions (IMFs), representing various dominating frequencies. These various frequencies represent noises from the body of the vehicle, sensor location, and the excitation induced by nature frequency of the vehicle, etc. IRI calculation can be achieved by eliminating noises that are not associated with the road profile including vehicle inertia effect. The resulting IRI values are compared favorably to the field IRI values, where the filtered IMFs captures the most characteristics of road profile while eliminating noises from the vehicle and the vehicle inertia effect. Therefore, HHT is an effect method for road profile analysis and for IRI measurement. Furthermore, the application of HHT method has the potential to eliminate the use of accelerometers attached to the vehicle as part of the displacement measurement used to offset the inertia effect.

  5. Systemic and Ophthalmologic Findings in Patients with Iris Coloboma

    Directory of Open Access Journals (Sweden)

    Sevda Ertekin

    2013-01-01

    Full Text Available Pur po se: Ocular coloboma is a rare malformation resulting from defective closure of the embryonic optic fissure. It can affect iris, retina, choroid, optic disc or ciliary body. This study reviews the clinical diagnosis and the accompanying ocular and systemic abnormalities in cases of iris coloboma. Ma te ri al and Met hod: Sixteen eyes of ten patients referred to our clinic and diagnosed as iris coloboma were included in the study and were reviewed retrospectively. Re sults: Seven cases were sporadic, and three cases were familial. Isolated iris coloboma was present in only one case, and chorioretinal involvement was present in all the others. Seven cases had involvement of the optic disc. Other ocular anomalies were unilateral microphthalmia in 3 cases, unilateral anophthalmia in 1 case, and unilateral microcornea in one case. Strabismus was present in the familial cases. Dis cus si on: In patients, diagnosed with iris coloboma, routine eye examination should be completed, refractive errors should be corrected, and these patients must be follewed for amblyopia. If strabismus is concominant, surgery can be performed. For potential complications, patients should be checked at regular intervals. (Turk J Ophthalmol 2013; 43: 19-22

  6. Aqueous humor tyrosinase activity is indicative of iris melanocyte toxicity.

    Science.gov (United States)

    Mahanty, Sarmistha; Kawali, Ankush A; Dakappa, Shruthi Shirur; Mahendradas, Padmamalini; Kurian, Mathew; Kharbanda, Varun; Shetty, Rohit; Setty, Subba Rao Gangi

    2017-09-01

    Antibiotics such as fluoroquinolones (FQLs) are commonly used to treat ocular infections but are also known to cause dermal melanocyte toxicity. The release of dispersed pigments from the iris into the aqueous humor has been considered a possible ocular side effect of the systemic administration of FQLs such as Moxifloxacin, and this condition is known as bilateral acute iris transillumination (BAIT). Bilateral acute depigmentation of iris (BADI) is a similar condition, with iris pigment released into the aqueous, but it has not been reported as a side effect of FQL. Iris pigments are synthesized by the melanogenic enzyme tyrosinase (TYR) and can be detected but not quantified by using slit-lamp biomicroscopy. The correlation between dispersed pigments in the aqueous and the extent of melanocyte toxicity due to topical antibiotics in vivo is not well studied. Here, we aimed to study the effect of topical FQLs on iris tissue, the pigment release in the aqueous humor and the development of clinically evident iris atrophic changes. We evaluated this process by measuring the activity of TYR in the aqueous humor of 82 healthy eyes undergoing cataract surgery following topical application of FQLs such as Moxifloxacin (27 eyes, preservative-free) or Ciprofloxacin (29 eyes, with preservative) or the application of non-FQL Tobramycin (26 eyes, with preservative) as a control. In addition, the patients were questioned and examined for ocular side effects in pre- and post-operative periods. Our data showed a significantly higher mean TYR activity in the aqueous humor of Ciprofloxacin-treated eyes compared to Moxifloxacin- (preservative free, p iris melanocytes. However, the reduced TYR activity in the aqueous of Moxifloxacin-treated eyes was possibly due to the presence of a higher drug concentration, which inhibits TYR activity. Consistently, immunoblotting analysis of the aqueous humor from both Ciprofloxacin- and Moxifloxacin-treated eyes showed the presence of soluble

  7. IRI profile parameters at equatorial latitudes

    International Nuclear Information System (INIS)

    Reinisch, B.W.; Huang Xueqin; Conway, J.

    2002-01-01

    The IRI bottom-side electron density profile is specified as a function of three parameters B0, B1, and D1 describing the F2 layer thickness and shape, and the shape of the F1 layer, respectively. Together with the URSI or CCIR coefficients for the F2 layer peak density and height, they completely specify the profiles as function of time, season and solar activity. In support of the international effort of determining the best set of parameters we have analyzed the diurnal variations of B0, B1, and D1 for Jicamarca for high solar activity during 1999 and 2000 for different seasons and magnetic activity. The B0 values vary from a minimum of ∼95 km at 0300 LT to ∼250 km at local noon (1700 UT). The diurnal variation is similar to the IRI2000 prediction. B1 varies from ∼1.9 at daytime to ∼2.2 at night. The value of D1 is ∼0.5. The parameters show little Kp dependence. Standard deviations are shown. We calculated the ionospheric total electron contents for March and April 1998 from the ionogram profiles at Jicamarca and compared them with IRI predictions using the IRI 2000 parameters. While there is fair agreement, a significant time shift of 1 to 2 hours occurs in the transition from night to daytime values. (author)

  8. Comparison of features response in texture-based iris segmentation

    CSIR Research Space (South Africa)

    Bachoo, A

    2009-03-01

    Full Text Available the Fisher linear discriminant and the iris region of interest is extracted. Four texture description methods are compared for segmenting iris texture using a region based pattern classification approach: Grey Level Co-occurrence Matrix (GLCM), Discrete...

  9. An IRIS Optically Thin View of the Dynamics of the Solar Chromosphere

    Science.gov (United States)

    Carlsson, M.

    2017-12-01

    We analyze the formation of the O I 1356 and Cl I 1351 lines and show that they are formed in the mid-chromosphere and are optically thin. Their non-thermal line-widths are thus a direct measure of the velocity field along the line of sight. We use this insight to analyze a large set of observations from the Interface Region Imaging Spectrograph (IRIS) to study the dynamics of the Solar Chromosphere.

  10. Analysis of iris surface features in populations of diverse ancestry

    Science.gov (United States)

    Edwards, Melissa; Cha, David; Krithika, S.; Johnson, Monique; Parra, Esteban J.

    2016-01-01

    There are many textural elements that can be found in the human eye, including Fuchs’ crypts, Wolfflin nodules, pigment spots, contraction furrows and conjunctival melanosis. Although iris surface features have been well-studied in populations of European ancestry, the worldwide distribution of these traits is poorly understood. In this paper, we develop a new method of characterizing iris features from photographs of the iris. We then apply this method to a diverse sample of East Asian, European and South Asian ancestry. All five iris features showed significant differences in frequency between the three populations, indicating that iris features are largely population dependent. Although none of the features were correlated with each other in the East and South Asian groups, Fuchs’ crypts were significantly correlated with contraction furrows and pigment spots and contraction furrows were significantly associated with pigment spots in the European group. The genetic marker SEMA3A rs10235789 was significantly associated with Fuchs’ crypt grade in the European, East Asian and South Asian samples and a borderline association between TRAF3IP1 rs3739070 and contraction furrow grade was found in the European sample. The study of iris surface features in diverse populations may provide valuable information of forensic, biomedical and ophthalmological interest. PMID:26909168

  11. An enhanced iris recognition and authentication system using ...

    African Journals Online (AJOL)

    Iris recognition and authentication has a major issue in its code generation and verification accuracy, in order to enhance the authentication process, a binary bit sequence of iris is generated, which contain several vital information that is used to calculate the Mean Energy and Maximum Energy that goes into the eye with an ...

  12. IRIS. Progress in licensing and toward deployment

    International Nuclear Information System (INIS)

    Petrovic, B.; Carelli, M.D.; Kling, C.L.; Cavlina, N.; Grgic, D.

    2006-01-01

    The International Reactor Innovative and Secure (IRIS) is an advanced, integral, light water cooled, pressurized reactor of smaller generating capacity (1000 MWt, or 335 MWe). It is being developed through a strong international partnership by a team lead by Westinghouse and including organizations from 10 countries. The main objective of the project is to offer a simple nuclear power plant with outstanding safety, attractive economics and enhanced proliferation resistance characteristics ready for deployment within the next decade. IRIS embodies the requirements set forth by the recently announced US DOE Global Nuclear Energy Partnership (GNEP) program for worldwide deployment of a smaller-scale reactors and provides a viable bridge to Generation IV reactors. IRIS is designed to address the needs of both developed and emerging markets. Its smaller power level provides deployment flexibility in larger developed markets, and makes it in particular well suited for markets with limited grids or where the annual energy demand growth is moderate. Due to its short construction time and the staggered build option, IRIS significantly reduces the required financing, improves cash flow, and provides a viable solution for economies with limited resources. While based on proven and worldwide accepted LWR technology, IRIS introduces a number of innovative solutions to simplify its design and improve safety and operational characteristics, including the integral primary system and its components, as well as the safety-by-design approach. These features will be tested and demonstrated in a testing program that has been initiated. As its centerpiece, the program will include the integral test facility. Results of this program will support licensing with the US NRC. A multinational licensing is considered to facilitate worldwide deployment. (author)

  13. IRIS Toxicological Review of Vinyl Chloride (Final Report, 2000)

    Science.gov (United States)

    EPA is announcing the release of the final report, Toxicological Review of Vinyl Chloride: in support of the Integrated Risk Information System (IRIS). The updated Summary for Vinyl Chloride and accompanying Quickview have also been added to the IRIS Database.

  14. Evidence for two-loop interaction from IRIS and SDO observations of penumbral brightenings

    Science.gov (United States)

    Alissandrakis, C. E.; Koukras, A.; Patsourakos, S.; Nindos, A.

    2017-07-01

    Aims: We investigate small scale energy release events which can provide clues on the heating mechanism of the solar corona. Methods: We analyzed spectral and imaging data from the Interface Region Imaging Spectrograph (IRIS), images from the Atmospheric Imaging Assembly (AIA) aboard the Solar Dynamics Observatoty (SDO), and magnetograms from the Helioseismic and Magnetic Imager (HMI) aboard SDO. Results: We report observations of small flaring loops in the penumbra of a large sunspot on July 19, 2013. Our main event consisted of a loop spanning 15'', from the umbral-penumbral boundary to an opposite polarity region outside the penumbra. It lasted approximately 10 min with a two minute impulsive peak and was observed in all AIA/SDO channels, while the IRIS slit was located near its penumbral footpoint. Mass motions with an apparent velocity of 100 km s-1 were detected beyond the brightening, starting in the rise phase of the impulsive peak; these were apparently associated with a higher-lying loop. We interpret these motions in terms of two-loop interaction. IRIS spectra in both the C II and Si iv lines showed very extended wings, up to about 400 km s-1, first in the blue (upflows) and subsequently in the red wing. In addition to the strong lines, emission was detected in the weak lines of Cl I, O I and C I, as well as in the Mg II triplet lines. Absorption features in the profiles of the C II doublet, the Si iv doublet and the Mg II h and k lines indicate the existence of material with a lower source function between the brightening and the observer. We attribute this absorption to the higher loop and this adds further credibility to the two-loop interaction hypothesis. Tilts were detected in the absorption spectra, as well as in the spectra of Cl I, O I, and C I lines, possibly indicating rotational motions from the untwisting of magnetic flux tubes. Conclusions: We conclude that the absorption features in the C II, Si iv and Mg II profiles originate in a higher

  15. 75 FR 25239 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2010-05-07

    ... Information System (IRIS); Announcement of Availability of Literature Searches for IRIS Assessments AGENCY: Environmental Protection Agency. ACTION: Notice; Announcement of availability of literature searches for IRIS... the availability of literature searches for four IRIS assessments and requesting scientific...

  16. Iris small break loca phenomena identification and ranking table (PIRT)

    International Nuclear Information System (INIS)

    Larson, T.K.; Moody, F.J.; Wilson, G.E.; Brown, W.L.; Frepoli, C.; Hartz, J.; Woods, B.G.; Oriani, L.

    2007-01-01

    The international reactor innovative and secure (IRIS) is a modular pressurized water reactor with an integral configuration (all primary system components - reactor core, internals, pumps, steam generators, pressurizer, and control rod drive mechanisms - are inside the reactor vessel). The IRIS plant conceptual design was completed in 2001 and the preliminary design is currently underway. The pre-application licensing process with the United States Nuclear Regulatory Commission (USNRC) started in October 2002. The first line of defense in IRIS is to eliminate event initiators that could potentially lead to core damage. If it is not possible to eliminate certain accidents altogether, then the design inherently reduces their consequences and/or decreases their probability of occurring. One of the most obvious advantages of the IRIS Safety-by-Design TM approach is the elimination of large break loss-of-coolant accidents (LBLOCAs), since no large primary penetrations of the reactor vessel or large loop piping exist. While the IRIS Safety-by-Design TM approach is a logical step in the effort to produce advanced reactors, the desired advances in safety must still be demonstrated in the licensing arena. With the elimination of LBLOCA, an important next consideration is to show the IRIS design fulfills the promise of increased safety also for small break LOCAs (SBLOCAs). Accordingly, the SBLOCA phenomena identification and ranking table (PIRT) project was established. The primary objective of the IRIS SBLOCA PIRT project was to identify the relative importance of phenomena in the IRIS response to SBLOCAs. This relative importance, coupled with the current relative state of knowledge for the phenomena, provides a framework for the planning of the continued experimental and analytical efforts. To satisfy the SBLOCA PIRT project objectives, Westinghouse organized an expert panel whose members were carefully selected to insure that the PIRT results reflect internationally

  17. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) (Public Comment Draft)

    Science.gov (United States)

    In September 2016, the U.S. Environmental Protection Agency's (USEPA) released the draft Integrated Risk Information System (IRIS) Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE). Consistent with the 2013 IRIS Enhancements, draft IRIS assessments are released prior to e...

  18. A plant control system development approach for IRIS

    International Nuclear Information System (INIS)

    Wood, R.T.; Brittain, C.R.; March-Leuba, J.A.; Conway, L.E.; Oriani, L.

    2003-01-01

    The plant control system concept for the International Reactor Innovative and Secure (IRIS) will make use of integrated control, diagnostic, and decision modules to provide a highly automated intelligent control capability. The plant control system development approach established for IRIS involves determination and verification of control strategies based on whole-plant simulation; identification of measurement, control, and diagnostic needs; development of an architectural framework in which to integrate an intelligent plant control system; and design of the necessary control and diagnostic elements for implementation and validation. This paper describes key elements of the plant control system development approach established for IRIS and presents some of the strategies and methods investigated to support the desired control capabilities. (author)

  19. 75 FR 76982 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2010-12-10

    ... Information System (IRIS); Announcement of Availability of Literature Searches for IRIS Assessments AGENCY: Environmental Protection Agency. ACTION: Announcement of availability of literature searches for IRIS... the availability of literature searches for four IRIS assessments, acetaldehyde (CAS No. 75-07-0...

  20. Lentes plegables suturadas a iris

    Directory of Open Access Journals (Sweden)

    Dunia Cruz Izquierdo

    Full Text Available Para la corrección quirúrgica de la afaquia existen en la actualidad varias técnicas quirúrgicas que permiten fijar los lentes intraoculares plegables o rígidos en cámara posterior suturados al iris o al sulcus ciliar. En estas circunstancias el cirujano determinará cuándo, dónde y el tipo de lente mejor a implantar. Se presenta un paciente con una afaquia traumática del ojo izquierdo, con agudeza visual sin corrección de movimiento de mano a 1 m. Se le realizó implante secundario de lente intraocular plegable de cámara posterior suturada al iris. En el examen biomicroscópico en lámpara de hendidura del ojo izquierdo se observó midriasis media paralítica, refracción dinámica de +11,00 (0,6 y tensión ocular normal. Se le realizó examen por bimicroscopía indirecta sin alteración. Al mes de operado la agudeza visual mejor corregida alcanzó la unidad de visión. Las complicaciones presentadas fueron ovalización de la pupila y depósitos de pigmentos de iris en el lente intraocular.

  1. Proceedings of the IRI Task Force Activity 2001

    International Nuclear Information System (INIS)

    Radicella, S.M.

    2002-08-01

    This ICTP Internal Report contains the list of papers presented, activity report and the write up of a number of presentations delivered during the International Reference Ionosphere (IRI) Task Force Activity 2001 which took place at the Abdus Salam ICTP during May 2001, particularly centred in the week from 21-25 May. The 2001 Task Force Activity is the eighth successful encounter of specialists organized by the URSI-Cospar IRI Working Group and the Aeronomy and Radiopropagation Laboratory of the Abdus Salam International Centre for Theoretical Physics of Trieste, Italy. This project continues the IRI Task Force Activities at the Abdus Salam International Centre for Theoretical Physics (ICTP) in Trieste, Italy. The primary focus of this activity was the development of a specification model for ionospheric variability. Such a model is high on the wish list of users of ionospheric models. Climatological models like IRI provide monthly mean values of ionospheric parameters. Understandably a satellite designer or operator needs to know not only the monthly average conditions but also the expected deviations from these mean values. The main discussions and presentations took place during the week 21-25 May. The format was similar to last year's activity with presentations and round-table discussions in the morning and follow-on work in small subgroups in front of computer terminals in the afternoon. This Proceedings contains also four papers of the previous IRI Task Force Activity which were omitted

  2. Secondary iris recognition method based on local energy-orientation feature

    Science.gov (United States)

    Huo, Guang; Liu, Yuanning; Zhu, Xiaodong; Dong, Hongxing

    2015-01-01

    This paper proposes a secondary iris recognition based on local features. The application of the energy-orientation feature (EOF) by two-dimensional Gabor filter to the extraction of the iris goes before the first recognition by the threshold of similarity, which sets the whole iris database into two categories-a correctly recognized class and a class to be recognized. Therefore, the former are accepted and the latter are transformed by histogram to achieve an energy-orientation histogram feature (EOHF), which is followed by a second recognition with the chi-square distance. The experiment has proved that the proposed method, because of its higher correct recognition rate, could be designated as the most efficient and effective among its companion studies in iris recognition algorithms.

  3. [Analysis of iris: history and future].

    Science.gov (United States)

    Norn, Mogens

    2003-01-01

    Analysis of the iris has ancient roots, but iridology in its present sense was established by Philippi Meyers in 1670. The discipline was further developed by Ignaz Péczely in 1881 and by Nils Liljequist in 1890. Other studies have been published in Germany, Sweden, Norway, England, France, USA, Australia and elsewhere, and iridology is practiced worldwide. The techniques used are described and the sources of error are mentioned when several photos from the same patient are compared (e.g. the influences of differences in pupil size, magnification and the effect of oblique light). The iris key (irigraphy) and the interpretation of different sights are discussed in some detail; there is little agreement among iridologists. Some iris diagnoses are of little interest to day and some modern diseases are missing in the diagnostic system. Controlled studies reveal that iridology is of no use whatsoever for the detection of cancer and other diseases in the stomach, intestines, kidney, lungs and heart. The reason for the continued popularity of iridology is discussed, and it is concluded that this type of alternative medicine is not harmless.

  4. IRIS Responsiveness to Generation IV Road-map Goals

    International Nuclear Information System (INIS)

    Carelli, M.D.; Paramonov, D.V.; Petrovic, B.

    2002-01-01

    The DOE Generation IV road-map process is in its second and final year. Almost one hundred concepts submitted from all over the world have been reviewed against the Generation IV goals of resources sustainability; safety and reliability; and, economics. Advanced LWRs are taken as the reference point. IRIS (International Reactor Innovative and Secure), a 100-335 MWe integral light water reactor being developed by a vast international consortium led by Westinghouse, is one on the concepts being considered in the road-map and is perhaps the most visible representative of the concept set known as Integral Primary System Reactors (IPSR). This paper presents how IRIS satisfies the prescribed goals. The first goal of resource sustainability includes criteria like utilization of fuel resources, amount and toxicity of waste produced, environmental impact, proliferation and sabotage resistance. As a thermal reactor IRIS does not have the same fuel utilization as fast reactors. However, it has a significant flexibility in fuel cycles as it is designed to utilize either UO 2 or MOX with straight burn cycles of 4 to 10 years, depending on the fissile content. High discharge burnup and Pu recycling result in good fuel utilization and lower waste; IRIS has also attractive proliferation resistance characteristics, due to the reduced accessibility of the fuel. The safety and reliability goal include reliability, workers' exposure, robust safety features, models with well characterized uncertainty, source term and mechanisms of energy release, robust mitigation of accidents. IRIS is significantly better than advanced LWRs because of its safety by design which eliminates a variety of accidents such as LOCAs, its containment vessel coupled design which maintains the core safely covered during the accident sequences, its design simplification features such as no (or reduced) soluble boron, internal shielding and four-year refueling/maintenance interval which significantly reduce

  5. Iris segmentation using an edge detector based on fuzzy sets theory and cellular learning automata.

    Science.gov (United States)

    Ghanizadeh, Afshin; Abarghouei, Amir Atapour; Sinaie, Saman; Saad, Puteh; Shamsuddin, Siti Mariyam

    2011-07-01

    Iris-based biometric systems identify individuals based on the characteristics of their iris, since they are proven to remain unique for a long time. An iris recognition system includes four phases, the most important of which is preprocessing in which the iris segmentation is performed. The accuracy of an iris biometric system critically depends on the segmentation system. In this paper, an iris segmentation system using edge detection techniques and Hough transforms is presented. The newly proposed edge detection system enhances the performance of the segmentation in a way that it performs much more efficiently than the other conventional iris segmentation methods.

  6. The influence of iris color on the pupillary light reflex.

    Science.gov (United States)

    Bergamin, O; Schoetzau, A; Sugimoto, K; Zulauf, M

    1998-08-01

    This study was carried out to investigate the effect of iris color on the pupillary light reflex (PLR) in normal healthy volunteers. Pupil perimetry was performed on 50 healthy volunteers with the Octopus 1-2-3 automated perimeter. Within the 30-deg visual field, 33 test locations were investigated four times. Stimulus parameters were Goldmann size V (1.72 degrees), intensity 1632 cd/m2, stimulus time 200 ms, background illumination 0 cd/m2, and interstimulus interval 3 s. Pupillometric parameters studied were initial pupil size, amplitude (magnitude of pupillary contraction), latency time, contraction time, pre-PLR movement, contraction velocity, and redilation velocity. Pupillometric parameters were investigated by analysis of variance by the independent variables blue and brown irides. Iris color (blue vs brown) influenced statistically significantly (P movement (0.328 mm2/s vs 0.325 mm2/s). Pupillary contraction amplitude and velocity depended on iris color, whereas pupil size and latency time were independent of iris color. Therefore, iris color might be considered when, evaluating pupillary movements in pupil perimetry.

  7. Iris Segmentation using Gradient Magnitude and Fourier Descriptor for Multimodal Biometric Authentication System

    Directory of Open Access Journals (Sweden)

    Defiana Sulaeman

    2016-12-01

    Full Text Available Perfectly segmenting the area of the iris is one of the most important steps in iris recognition. There are several problematic areas that affect the accuracy of the iris segmentation step, such as eyelids, eyelashes, glasses, pupil (due to less accurate iris segmentation, motion blur, and lighting and specular reflections. To solve these problems, gradient magnitude and Fourier descriptor are employed to do iris segmentation in the proposed Multimodal Biometric Authentication System (MBAS. This approach showed quite promising results, i.e. an accuracy rate of 97%. The result of the iris recognition system was combined with the result of an open-source fingerprint recognition system to develop a multimodal biometrics authentication system. The results of the fusion between iris and fingerprint authentication were 99% accurate. Data from Multimedia Malaysia University (MMUI and our own prepared database, the SGU-MB-1 dataset, were used to test the accuracy of the proposed system.

  8. SURVEY OF BIOMETRIC SYSTEMS USING IRIS RECOGNITION

    OpenAIRE

    S.PON SANGEETHA; DR.M.KARNAN

    2014-01-01

    The security plays an important role in any type of organization in today’s life. Iris recognition is one of the leading automatic biometric systems in the area of security which is used to identify the individual person. Biometric systems include fingerprints, facial features, voice recognition, hand geometry, handwriting, the eye retina and the most secured one presented in this paper, the iris recognition. Biometric systems has become very famous in security systems because it is not possi...

  9. Uso de la triamcinolona subtenoniana en pacientes con rubeosis del iris Use of intravitreal triamcinolone in patients with iris rubeosis

    Directory of Open Access Journals (Sweden)

    Irene Rojas Rondón

    2008-12-01

    Full Text Available OBJETIVO: Describir el comportamiento de la rubeosis del iris luego de la aplicación de triamcinolona subtenoniana. MÉTODOS: Se realizó un estudio descriptivo de corte longitudinal con 25 pacientes para un total de 32 ojos con diferentes afecciones oculares. Se efectuaron pruebas estadísticas con las variables del estudio y en algunas se utilizó la prueba de los signos de comparación para datos pareados y en otras se aplicó chi cuadrado. Se caracterizaron las variables: edad, sexo, causa de rubeosis del iris y sus estadios, síntomas y tratamiento con láser de panfotocoagulación retiniana. RESULTADOS: La retinopatía diabética proliferativa fue la afección más frecuente en el 76 % de los pacientes, seguida de la oclusión de la vena central retiniana. Del total de pacientes tratados, el 37,5 % evolucionó satisfactoriamente el estado de la rubeosis del iris. Fue mayor el número de pacientes que mejoraron el grado de la rubeosis con tratamiento combinado de láser y triamcinolona subtenoniana, aunque estadísticamente no fue significativo. El estado de la rubeosis mejoró en más de la mitad de los pacientes con tiempo de evolución menor de 6 meses. En aquellos con un tiempo mayor de 6 meses y neovascularización del iris grado III, se pudo estabilizar el glaucoma neovascular. CONCLUSIÓN: Se plantea que la triamcinolona subtenoniana constituye una alternativa para el manejo de este tipo de pacientes.OBJECTIVE: To describe the behaviour of iris rubeosis after using intravitreal triamcinolone. METHODS: A longitudinal descriptive study was performed on 25 patients for a total number of 32 eyes with several ocular diseases. Statistical tests were made with the study variables; sign comparison for paired data and Chi square tests were applied. The variables were age, sex, cause of iris rubeosis and its staging, symptoms and treatment with retinal photocoagulation laser. RESULTS: Proliferative diabetic retinopathy was the most common

  10. IRIS Toxicological Review of Ammonia (Revised External Review Draft)

    Science.gov (United States)

    In August 2013, EPA submitted a revised draft IRIS assessment of ammonia to the agency's Science Advisory Board (SAB) and posted this draft on the IRIS website. EPA had previously released a draft of the assessment for public comment, held a public meeting about the draft, and ...

  11. Hyaluronic acid production and hyaluronidase activity in the newt iris during lens regeneration

    International Nuclear Information System (INIS)

    Kulyk, W.M.; Zalik, S.E.; Dimitrov, E.

    1987-01-01

    The process of lens regeneration in newts involves the dedifferentiation of pigmented iris epithelial cells and their subsequent conversion into lens fibers. In vivo this cell-type conversion is restricted to the dorsal region of the iris. We have examined the patterns of hyaluronate accumulation and endogenous hyaluronidase activity in the newt iris during the course of lens regeneration in vivo. Accumulation of newly synthesized hyaluronate was estimated from the uptake of [ 3 H]glucosamine into cetylpyridinium chloride-precipitable material that was sensitive to Streptomyces hyaluronidase. Endogenous hyaluronidase activity was determined from the quantity of reducing N-acetylhexosamine released upon incubation of iris tissue extract with exogenous hyaluronate substrate. We found that incorporation of label into hyaluronate was consistently higher in the regeneration-activated irises of lentectomized eyes than in control irises from sham-operated eyes. Hyaluronate labeling was higher in the dorsal (lens-forming) region of the iris than in ventral (non-lens-forming) iris tissue during the regeneration process. Label accumulation into hyaluronate was maximum between 10 and 15 days after lentectomy, the period of most pronounced dedifferentiation in the dorsal iris epithelium. Both normal and regenerating irises demonstrated a high level of endogenous hyaluronidase activity with a pH optimum of 3.5-4.0. Hyaluronidase activity was 1.7 to 2 times higher in dorsal iris tissue than in ventral irises both prior to lentectomy and throughout the regeneration process. We suggest that enhanced hyaluronate accumulation may facilitate the dedifferentiation of iris epithelial cells in the dorsal iris and prevent precocious withdrawal from the cell cycle. The high level of hyaluronidase activity in the dorsal iris may promote the turnover and remodeling of extracellular matrix components required for cell-type conversion

  12. Iris reactor conceptual design

    International Nuclear Information System (INIS)

    Carelli, M.D.; Conway, L.E.; Petrovic, B.; Paramonov, D.V.; Galvin, M.; Todreas, N.E.; Lombardi, C.V.; Maldari, F.; Ricotti, M.E.; Cinotti, L.

    2001-01-01

    IRIS (International Reactor Innovative and Secure) is a modular, integral, light water cooled, low-to-medium power (100-350 MWe) reactor which addresses the requirements defined by the US DOE for Generation IV reactors, i.e., proliferation resistance, enhanced safety, improved economics and fuel cycle sustainability. It relies on the proven technology of light water reactors and features innovative engineering, but it does not require new technology development. This paper discusses the current reference IRIS design, which features a 1000 MWt thermal core with proven 5%-enriched uranium oxide fuel and five-year long straight burn fuel cycle, integral reactor vessel housing helical tube steam generators and immersed spool pumps. Other major contributors to the high level of safety and economic attractiveness are the safety by design and optimized maintenance approaches, which allow elimination of some classes of accidents, lower capital cost, long operating cycle, and high capacity factors. (author)

  13. Three-batch reloading scheme for IRIS reactor extended cycles

    International Nuclear Information System (INIS)

    Jecmenica, R.; Pevec, D.; Grgic, D.

    2004-01-01

    To fully exploit the IRIS reactor optimized maintenance, and at the same time improve fuel utilization, a core design enabling a 4-year operating cycle together with a three-batch reloading scheme is desirable. However, this requires not only the increased allowed burnup but also use of fuel with uranium oxide enriched beyond 5%. This paper considers three-batch reloading scheme for a 4-year operating cycle with the assumptions of increased discharge burnup and fuel enrichment beyond 5%. Calculational model of IRIS reactor core has been developed based on FER FA2D code for group constants generation and NRC's PARCS nodal code for global core analysis. Studies have been performed resulting in a preliminary design of a three-batch core configuration for the first cycle. It must be emphasized that this study is outside the current IRIS licensing efforts, which rely on the present fuel technology (enrichment below 5%), but it is of long-term interest for potential future IRIS design upgrades. (author)

  14. Challenges at different stages of an iris based biometric system

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Singla

    2012-04-01

    Full Text Available Iris recognition has been used for authentication for the past few years and is capable of positive/negative authenticationof an individual without any physical contact or intervention. This technique is being used mainly because of its uniqueness,stability, and reliability but still many challenges are being faced an the iris based recognition system. This paperpresents the difficulties faced in different modules, like the sensor module, preprocessing module, feature extraction module,and matching module of an iris biometric system.

  15. 78 FR 53466 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-08-29

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... National Customs Automation Program (NCAP) tests concerning document imaging, known as the Document Image... the National Customs Automation Program (NCAP) tests concerning document imaging, known as the...

  16. Extending the depth of field with chromatic aberration for dual-wavelength iris imaging.

    Science.gov (United States)

    Fitzgerald, Niamh M; Dainty, Christopher; Goncharov, Alexander V

    2017-12-11

    We propose a method of extending the depth of field to twice that achievable by conventional lenses for the purpose of a low cost iris recognition front-facing camera in mobile phones. By introducing intrinsic primary chromatic aberration in the lens, the depth of field is doubled by means of dual wavelength illumination. The lens parameters (radius of curvature, optical power) can be found analytically by using paraxial raytracing. The effective range of distances covered increases with dispersion of the glass chosen and with larger distance for the near object point.

  17. Academy Distance Learning Tools (IRIS) -

    Data.gov (United States)

    Department of Transportation — IRIS is a suite of front-end web applications utilizing a centralized back-end Oracle database. The system fully supports the FAA Academy's Distance Learning Program...

  18. The IRI/LDEO Climate Data Library: Helping People use Climate Data

    Science.gov (United States)

    Blumenthal, M. B.; Grover-Kopec, E.; Bell, M.; del Corral, J.

    2005-12-01

    The IRI Climate Data Library (http://iridl.ldeo.columbia.edu/) is a library of datasets. By library we mean a collection of things, collected from both near and far, designed to make them more accessible for the library's users. Our datasets come from many different sources, many different "data cultures", many different formats. By dataset we mean a collection of data organized as multidimensional dependent variables, independent variables, and sub-datasets, along with the metadata (particularly use-metadata) that makes it possible to interpret the data in a meaningful manner. Ingrid, which provides the infrastructure for the Data Library, is an environment that lets one work with datasets: read, write, request, serve, view, select, calculate, transform, ... . It hides an extraordinary amount of technical detail from the user, letting the user think in terms of manipulations to datasets rather that manipulations of files of numbers. Among other things, this hidden technical detail could be accessing data on servers in other places, doing only the small needed portion of an enormous calculation, or translating to and from a variety of formats and between "data cultures". These operations are presented as a collection of virtual directories and documents on a web server, so that an ordinary web client can instantiate a calculation simply by requesting the resulting document or image. Building on this infrastructure, we (and others) have created collections of dynamically-updated images to faciliate monitoring aspects of the climate system, as well as linking these images to the underlying data. We have also created specialized interfaces to address the particular needs of user groups that IRI needs to support.

  19. Outcomes of iris-claw anterior chamber versus iris-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome.

    Science.gov (United States)

    Hirashima, Denise E; Soriano, Eduardo S; Meirelles, Rodrigo L; Alberti, Gustave N; Nosé, Walton

    2010-08-01

    To compare the outcome of phacoemulsification using 2 different iris-fixation techniques for intraocular lens (IOL) replacement, a foldable posterior chamber IOL (PCIOL; AcrySof MA60AC, Alcon Laboratories Inc, Fort Worth, TX) and an iris-claw anterior chamber IOL (ACIOL; Artisan, Ophtec BV), for treatment of subluxated lenses in patients with Marfan syndrome (MFS). Randomized, controlled trial. A total of 31 eyes of 16 patients with subluxated lenses associated with MFS and a preoperative corrected visual acuity (CVA) IOL type. Preoperative and postoperative ophthalmologic examination, optical coherence tomography, and endothelial cell counts were performed. We recorded CVA results at 3, 6, and 12 months, complications, endothelial cell loss, and central retinal thickness. In the iris-fixated PCIOL group, CVA was significantly improved at 3 (P = 0.011; n = 16), 6 (P = 0.006; n = 16), and 12 months (P = 0.002; n = 16). In the iris-claw ACIOL group, CVA was significantly improved at 3 (P = 0.001; n=15), 6 (P = 0.001; n = 15), and 12 months (P = 0.009; n = 12). The CVA results did not differ significantly between groups. Dislocation of the IOL occurred in 3 of 16 (18.75%) eyes in the PCIOL group. Retinal detachment occurred in 3 eyes (2 in the PCIOL group and 1 in the ACIOL group) and was successfully repaired. Postoperative foveal tomograms in both groups revealed a decrease in the mean foveal thickness (MFT; IOL dislocation tended to occur more frequently in the iris-fixated PCIOL group, the difference was not significant. At 6 months postoperatively, all study patients tended to have a thinner MFT. None of the patients in either group developed cystoid macular edema. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Association of iris crypts with acute primary angle closure.

    Science.gov (United States)

    Koh, Victor; Chua, Jacqueline; Shi, Yuan; Thakku, Sri Gowtham; Lee, Ryan; Nongpiur, Monisha E; Baskaran, Mani; Kumar, Rajesh S; Perera, Shamira; Aung, Tin; Cheng, Ching-Yu

    2017-10-01

    To determine the relationship between iris surface features and acute primary angle closure (APAC) in eyes with angle closure. Case-control study involving Asian patients diagnosed with previous APAC, primary angle closure suspect (PACS), primary angle closure (PAC) and primary angle closure glaucoma (PACG) at an eye centre in Singapore between August 2012 and January 2015. Participants underwent ophthalmic examination and digital slit-lamp iris photography. Iris surface features were graded based on crypts, furrows and colour. Fellow eyes of APAC were compared with PACS and PAC/PACG eyes with regard to their iris surface features. Occurrence of APAC. A total of 309 patients (71 APAC, 139 PACS, 47 PAC and 52 PACG) were included (mean age: 67.7±7.2 years and 36.6% male). Compared with PACS, higher crypt grade was significantly associated with lower odds of APAC (OR=0.58 for one grade higher in crypt grade; p=0.027, adjusted for age, gender, ethnicity and pupil diameter). The results remained similar when compared with PAC/PACG group (OR=0.58 for one grade higher in crypt grade; p=0.043). We did not observe any significant associations between iris furrows or colour with presence of APAC. Our study comprising Asian eyes with angle closure suggests that the presence of a higher crypt grading may be protective for APAC. As such, assessing iris surface architecture for crypts could be a new measure for risk stratification of developing APAC in eyes with angle closure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Integrated Risk Information System (IRIS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA?s Integrated Risk Information System (IRIS) is a compilation of electronic reports on specific substances found in the environment and their potential to cause...

  2. IRIS Toxicological Review of Tetrahydrofuran (THF) (Interagency Science Discussion Draft)

    Science.gov (United States)

    EPA is releasing the draft report, Toxicological Review of Tetrahydrofuran, that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the iris/process.htm">IRIS Assessment Development Proc...

  3. TEC variability near northern EIA crest and comparison with IRI model

    Science.gov (United States)

    Aggarwal, Malini

    2011-10-01

    Monthly median values of hourly total electron content (TEC) is obtained with GPS at a station near northern anomaly crest, Rajkot (geog. 22.29°N, 70.74°E; geomag. 14.21°N, 144.9°E) to study the variability of low latitude ionospheric behavior during low solar activity period (April 2005 to March 2006). The TEC exhibit characteristic features like day-to-day variability, semiannual anomaly and noon bite out. The observed TEC is compared with latest International Reference Ionosphere (IRI) - 2007 model using options of topside electron density, NeQuick, IRI01-corr and IRI-2001 by using both URSI and CCIR coefficients. A good agreement of observed and predicted TEC is found during the daytime with underestimation at other times. The predicted TEC by NeQuick and IRI01-corr is closer to the observed TEC during the daytime whereas during nighttime and morning hours, IRI-2001 shows lesser discrepancy in all seasons by both URSI and CCIR coefficients.

  4. Secure and Robust Iris Recognition Using Random Projections and Sparse Representations.

    Science.gov (United States)

    Pillai, Jaishanker K; Patel, Vishal M; Chellappa, Rama; Ratha, Nalini K

    2011-09-01

    Noncontact biometrics such as face and iris have additional benefits over contact-based biometrics such as fingerprint and hand geometry. However, three important challenges need to be addressed in a noncontact biometrics-based authentication system: ability to handle unconstrained acquisition, robust and accurate matching, and privacy enhancement without compromising security. In this paper, we propose a unified framework based on random projections and sparse representations, that can simultaneously address all three issues mentioned above in relation to iris biometrics. Our proposed quality measure can handle segmentation errors and a wide variety of possible artifacts during iris acquisition. We demonstrate how the proposed approach can be easily extended to handle alignment variations and recognition from iris videos, resulting in a robust and accurate system. The proposed approach includes enhancements to privacy and security by providing ways to create cancelable iris templates. Results on public data sets show significant benefits of the proposed approach.

  5. An Analysis on Better Testing than Training Performances on the Iris Dataset

    NARCIS (Netherlands)

    Schutten, Marten; Wiering, Marco

    2016-01-01

    The Iris dataset is a well known dataset containing information on three different types of Iris flowers. A typical and popular method for solving classification problems on datasets such as the Iris set is the support vector machine (SVM). In order to do so the dataset is separated in a set used

  6. AHMCT Intelligent Roadway Information System (IRIS) technical support and testing

    Science.gov (United States)

    2011-12-31

    This report documents the research project AHMCT IRIS Technical Support and Testing, : performed under contract 65A0275, Task ID 1777. It presents an overview of the Intelligent : Roadway Information System (IRIS), and its design and function. ...

  7. Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing

    Directory of Open Access Journals (Sweden)

    Yu-Tzu Wang

    2017-01-01

    Full Text Available This study integrates cone-beam computed tomography (CBCT/laser scan image superposition, computer-aided design (CAD, and 3D printing (3DP to develop a technology for producing customized dental (orthodontic miniscrew surgical templates using polymer material. Maxillary bone solid models with the bone and teeth reconstructed using CBCT images and teeth and mucosa outer profile acquired using laser scanning were superimposed to allow miniscrew visual insertion planning and permit surgical template fabrication. The customized surgical template CAD model was fabricated offset based on the teeth/mucosa/bracket contour profiles in the superimposition model and exported to duplicate the plastic template using the 3DP technique and polymer material. An anterior retraction and intrusion clinical test for the maxillary canines/incisors showed that two miniscrews were placed safely and did not produce inflammation or other discomfort symptoms one week after surgery. The fitness between the mucosa and template indicated that the average gap sizes were found smaller than 0.5 mm and confirmed that the surgical template presented good holding power and well-fitting adaption. This study addressed integrating CBCT and laser scan image superposition; CAD and 3DP techniques can be applied to fabricate an accurate customized surgical template for dental orthodontic miniscrews.

  8. Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing.

    Science.gov (United States)

    Wang, Yu-Tzu; Yu, Jian-Hong; Lo, Lun-Jou; Hsu, Pin-Hsin; Lin, CHun-Li

    2017-01-01

    This study integrates cone-beam computed tomography (CBCT)/laser scan image superposition, computer-aided design (CAD), and 3D printing (3DP) to develop a technology for producing customized dental (orthodontic) miniscrew surgical templates using polymer material. Maxillary bone solid models with the bone and teeth reconstructed using CBCT images and teeth and mucosa outer profile acquired using laser scanning were superimposed to allow miniscrew visual insertion planning and permit surgical template fabrication. The customized surgical template CAD model was fabricated offset based on the teeth/mucosa/bracket contour profiles in the superimposition model and exported to duplicate the plastic template using the 3DP technique and polymer material. An anterior retraction and intrusion clinical test for the maxillary canines/incisors showed that two miniscrews were placed safely and did not produce inflammation or other discomfort symptoms one week after surgery. The fitness between the mucosa and template indicated that the average gap sizes were found smaller than 0.5 mm and confirmed that the surgical template presented good holding power and well-fitting adaption. This study addressed integrating CBCT and laser scan image superposition; CAD and 3DP techniques can be applied to fabricate an accurate customized surgical template for dental orthodontic miniscrews.

  9. Iris Murdoch armastusest / Udo uibo

    Index Scriptorium Estoniae

    Uibo, Udo, 1956-

    2010-01-01

    Londoni Kingstoni ülikool omandas 50 000 naesterlingi eest 164 Iris Murdochi kirja prantsuse kirjanikule, keeleeksperimentaatorile Raymond Quenaule, millest selgub Murdochi ühepoolne ning vastamata jäänud tunne Quenau suhtes.

  10. Generation of biomechanics three-dimensional image for development of projects of custom implants in titanium alloy

    International Nuclear Information System (INIS)

    Gregolin, Rafael Ferreira; Zavaglia, Cecilia Amelia de Camargo; Tokimatsu, Ruis Camargo; Joao Antonio Pereira

    2014-01-01

    Three-dimensional modeling is an indispensable tool in manufacturing biomodels. Only after the development of a 3D design can be produced, by rapid prototyping, CNC machining, identical models of the areas of the human body. To perform computational numerical analysis is essential the creation of three-dimensional models. To Custom prostheses the use of the image of the deployment region for the development of customized implant is extremely important because it assists in the process. Only with the 3D design of the deployment region is achieved by testing and improving the designer of the prosthesis with great perfection. In the study presented here was developed a three-dimensional modeling of the jaw of a patient by computed tomography (CT) of the skull of the same . The Invesalius software was used, from the files generated by CT, to create a 3D picture of the skull. This image was exported in STL format for Rhinoceros® software to be cleaned, smoothed and separate the region of interest. After working in Rhinoceros® the image was transformed into a NURBS solid and saved in IGES format. This extension (IGES) was chosen to export the image to the Ansys Workbench® software and thus perform a static structural finite element analysis by applying own forces and fixations of human anatomy. The greatest stress found in the mandible was 213.59 MPa. (author)

  11. Integrated electrochromic iris device for low power and space-limited applications

    International Nuclear Information System (INIS)

    Deutschmann, T; Oesterschulze, E

    2014-01-01

    We present a micro-electrooptical iris based on the electrochromic polymer poly(3,4-ethylenedioxythiophene). Two ring-shaped concentric polymer-segments embedded in a transparent electrochemical cell form the micro iris. The polymer layers change their absorption when an external voltage is applied. This iris device benefits from the absence of any mechanically moving part. This renders a very slim design possible, which is suited for small integrated camera systems. During operation the polymer maintains its absorbing state without power consumption. Its low driving voltage of maximum 1.5 V is beneficial for battery powered applications. The impact of the iris on the depth of focus and transmission control as well as its dynamical behavior will be addressed. (paper)

  12. Bilateral acute iris transillumination (BAIT initially misdiagnosed as acute iridocyclitis

    Directory of Open Access Journals (Sweden)

    Saban Gonul

    2015-04-01

    Full Text Available Bilateral acute iris transillumination (BAIT is a relatively new clinical entity characterized by bilateral acute loss of iris pigment epithelium, iris transillumination, pigment dispersion in the anterior chamber, and sphincter paralysis. We report the case of a 30-year-old male who was initially diagnosed with acute iridocyclitis in a different clinic and treated with topical and systemic corticosteroids. He was referred to our clinic to seek another opinion because his symptoms did not improve. An ocular examination revealed bilateral pigment dispersion into the anterior chamber, diffuse iris transillumination, pigment dusting on the anterior lens capsule, atonic and distorted pupils, and increased intraocular pressure, suggesting a diagnosis of BAIT rather than iridocyclitis. Clinicians should be aware of the differential diagnosis of syndromes associated with pigment dispersion from iridocyclitis to avoid aggressive anti-inflammatory therapy and detailed investigation for uveitis.

  13. Association between iris constitution and apolipoprotein e gene polymorphism in hypertensives.

    Science.gov (United States)

    Um, Jae-Young; Hwang, Chung-Yeon; Hwang, Woo-Jun; Kang, Sung-Do; Do, Keum-Rok; Cho, Ju-Jang; Cho, Jae-Woon; Kim, Sung-Hoon; Shin, Tae-Yong; Kim, Yun-Kyung; Kim, Hyung-Min; Hong, Seung-Heon

    2004-12-01

    Iridology is a complementary and alternative medicine (CAM) that involves the diagnosis of medical conditions by noting irregularities of the pigmentation in the iris. Iris constitution has a strong familial aggregation and heredity is implicated. Apolipoprotein E (apoE) gene polymorphism is one of the most well-studied genetic markers for vascular diseases, including hypertension. In this study, we investigated the relationship between iris constitution and apoE polymorphism in hypertensives. We classified 87 hypertensives and 79 controls according to iris constitution and determined the apoE genotype of each individual. A significantly higher percentage of individuals with neurogenic constitutions was found in the hypertensive group when compared with the control group (chi(2) = 40.244, p < 0.001). In addition, a neurogenic constitution increased the relative risk for hypertension for subjects with an apo epsilon2 or an epsilon4 allele (chi(2) = 4.086, p = 0.049, odds ratio = 2.633, confidence interval = 1.004-6.905). Our results imply that a neurogenic iris constitution enhances the relative risk for hypertension in subjects with the apo epsilon2 or epsilon4 allele. Furthermore, we attempted to evaluate the efficacy of iris constitutional medicine and to find an association with hypertension.

  14. Computational model for transient studies of IRIS pressurizer behavior; Modelo computacional para el estudio de transitorios en el compensador de presion IRIS

    Energy Technology Data Exchange (ETDEWEB)

    Rives Sanz, R.; Montesino Otero, M.E.; Gonzalez Mantecon, J.; Rojas Mazaira, L., E-mail: mmontesi@instec.cu [Higher Institute of Technology and Applied Science, La Habana (Cuba). Department of Nuclear Engineering; Lira, C.A. Brayner de Oliveira [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2014-07-01

    International Reactor Innovative and Secure (IRIS) excels other Small Modular Reactor (SMR) designs due to its innovative characteristics regarding safety. IRIS integral pressurizer makes the design of larger pressurizer system than the conventional PWR, without any additional cost. The IRIS pressurizer volume of steam can provide enough margins to avoid spray requirement to mitigate in-surge transient. The aim of the present research is to model the IRIS pressurizer's dynamic using the commercial finite volume Computational Fluid Dynamic code CFX 14. A symmetric tridimensional model equivalent to 1/8 of the total geometry was adopted to reduce mesh size and minimize processing time. The model considers the coexistence of three phases: liquid, steam, and vapor bubbles in liquid volume. Additionally, it takes into account the heat losses between the pressurizer and primary circuit. The relationships for interfacial mass, energy, and momentum transport are programmed and incorporated into CFX by using expressions in CFX Command Language (CCL) format. Moreover, several additional variables are defined for improving the convergence and allow monitoring of boron dilution sequences and condensation-evaporation rate in different control volumes. For transient states a non - equilibrium stratification in the pressurizer is considered. This paper discusses the model developed and the behavior of the system for representative transients sequences such as the in/out-surge transients and boron dilution sequences. The results of analyzed transients of IRIS can be applied to the design of pressurizer internal structures and components. (author)

  15. Severe pigment dispersion after iris-claw phakic intraocular lens implantation.

    Science.gov (United States)

    Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N

    2017-12-01

    A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  16. Severe pigment dispersion after iris-claw phakic intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Virgilio Galvis

    2017-01-01

    Full Text Available A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  17. IRIS Assessment Plan for Uranium (Scoping and Problem Formulation Materials)

    Science.gov (United States)

    In January 2018, EPA released the IRIS Assessment Plan for Uranium (Oral Reference Dose) (Scoping and Problem Formulation Materials). An IRIS Assessment Plan (IAP) communicates to the public the plan for assessing each individual chemical and includes summary informatio...

  18. IRIS Toxicological Review of Inorganic Arsenic (Cancer) ...

    Science.gov (United States)

    EPA's Science Advisory Board (SAB) conducted a review of the scientific basis supporting the human health cancer hazard and dose-response assessment of inorganic arsenic that will appear on the Integrated Risk Information System (IRIS) database. EPA revised the assessment and is now returning the assessment to the SAB and releasing the document to the public for a focused review of EPA's responses to the SAB recommendations. This draft IRIS health assessment addresses only cancer human health effects that may result from chronic exposure to this chemical.

  19. RECENT DEVELOPMENTS OF THE IRIS PROJECT OF INTEREST FOR LATIN AMERICA

    International Nuclear Information System (INIS)

    Carelli, M.D.; Petrovic, B.

    2004-01-01

    The IRIS (International Reactor Innovative and Secure) reactor design is being developed by an international consortium of 21 organizations from ten countries, including three members from Brazil and one from Mexico. This reflects the interest that Latin America has for a project which addresses the energy needs of the region. Presented here are some of the most recent developments in the IRIS project. The project's highest priority is the current pre-application licensing with the US NRC, which has required an investigation of the major accident sequences and a preliminary probabilistic risk assessment (PRA). The results of the accident analyses confirmed the outstanding inherent safety of the IRIS configuration and the PRA analyses indicated a core damage frequency due to internal events of the order of 2E-8. This not only highlights the enhanced safety characteristic of IRIS which should enhance its public acceptance, but it has also prompted IRIS to consider the possibility of being licensed without the need for off-site emergency response planning which would have a very positive economic implication. The modular IRIS, with each module rated at ∼ 335 MWe, is of course an ideal size for developing countries as it allows to easily introduce a moderate amount of power on limited electric grids. IRIS can be deployed in single modules in regions only requiring a few hundred MWs or in multiple modules deployed successively at time intervals in large urban areas requiring a larger amount of power increasing with time. IRIS is designed to operate ''hands-off'' as much as possible, with a small crew, having in mind deployment in areas with limited infrastructure. Thus IRIS has a 48-months maintenance interval, long refueling cycles in excess of three years, and is designed to increase as much as possible operational reliability. For example, the project has recently adopted internal control rod drive mechanisms to eliminate vessel head penetrations and the

  20. Prosessiautomaation häiriösuojaus

    OpenAIRE

    Aalto, Joni

    2015-01-01

    Opinnäytetyön tarkoituksena oli tutustua prosessiteollisuuden automaatio- ja ohjausjärjestelmien häiriösuojaukseen ja varmistaa sen oikeanlainen rakenne ja toiminta käytännössä. Työ tehtiin Insta Automation Oy:lle, joka vastaa Boliden Harjavallan sähkökunnossapidosta ja sähkösuunnittelusta. Työ tehtiin Boliden Harjavallan sulaton alueella. Työhön kuului häiriöttömän eli TE-maadoituksen rakenteen tarkastaminen ja mittaus sekä prosessinohjaukseen käytettävän Metso DNA-järjestelmän sähköns...

  1. Plateau iris secondary to iridociliary cysts.

    Science.gov (United States)

    Vila-Arteaga, J; Díaz-Céspedes, R A; Suriano, M M

    2015-11-01

    We present a case of plateau iris and glaucoma due to multiple unilateral iridociliary cysts. The patient was treated with iridotomy Nd: YAG laser and 360° iridoplasty, without achieving pressure control. Phacoemulsification improved the hypertension. Dynamic gonioscopy and OCT of the anterior chamber was also performed before and after treatment. Iridociliary cysts are a benign condition that can cause iris plateau configuration, and can produce a difficult to treat ocular hypertension. Cystotomy, peripheral iridoplasty, and other treatments have been proposed. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  2. INPRO economic assessment of the IRIS nuclear reactor for deployment in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves Filho, Orlando Joao Agostinho, E-mail: orlando@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN - RJ), Rua Helio de Almeida, 75, Cidade Universitaria, Ilha do Fundao, 21941-906 Rio de Janeiro, RJ (Brazil)

    2011-06-15

    Highlights: > First INPRO evaluation of IRIS economic competitiveness for deployment in Brazil. > Plant arrangement of three independent IRIS single units constructed in series. > Angra 3 reactor used as reference design for judgment of IRIS economic potential. > IRIS economically competes with 2nd generation nuclear power plants in Brazil - Abstract: This paper presents the results of the economic assessment of the International Reactor Innovative and Secure (IRIS) for deployment in Brazil using the assessment methodology developed under the International Project on Innovative Nuclear Reactors and Fuel Cycles (INPRO), co-ordinated by the International Atomic Energy Agency (IAEA). INPRO initiated in 2001 and has the main objective of helping to ensure that nuclear energy will be available to contribute in a sustainable manner to the energy needs of the 21st century. Among its missions is the development of a methodology to assess innovative nuclear energy systems (INSs) on a global, regional and national basis. In 2005, Brazil submitted a proposal for the assessment of two small-size reactors as components of an INS, completed with a conventional open nuclear fuel cycle based on enriched uranium. One of the reactors assessed was IRIS, a small-size, modular, integral-type PWR reactor. IRIS was evaluated with regard to the areas of reactor safety and economics only. This paper outlines the rationale for the study and summarizes the results of the economic assessment. The study concluded that the reference design of IRIS complies with most of INPRO economics criteria and has potential to comply with the remaining ones.

  3. IRIS: A global approach to nuclear power renaissance

    International Nuclear Information System (INIS)

    Carelli, M.D.

    2004-01-01

    Improved international reactor IRIS (International Reactor Innovative and Secure) is discussed. IRIS is defined as a modular reactor with integral arrangement and water coolant. Design of reactor core and fuel elements is considered. Use of radial neutron reflectors from stainless steel is favorable to decrease of cost and increase of reactor operation. Reactor maintenance, constructional safety and arrangement of plant are characterized. Economical analysis and marketing are performed [ru

  4. Test of the Practicality and Feasibility of EDoF-Empowered Image Sensors for Long-Range Biometrics.

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Tien, Chung-Hao

    2016-11-25

    For many practical applications of image sensors, how to extend the depth-of-field (DoF) is an important research topic; if successfully implemented, it could be beneficial in various applications, from photography to biometrics. In this work, we want to examine the feasibility and practicability of a well-known "extended DoF" (EDoF) technique, or "wavefront coding," by building real-time long-range iris recognition and performing large-scale iris recognition. The key to the success of long-range iris recognition includes long DoF and image quality invariance toward various object distance, which is strict and harsh enough to test the practicality and feasibility of EDoF-empowered image sensors. Besides image sensor modification, we also explored the possibility of varying enrollment/testing pairs. With 512 iris images from 32 Asian people as the database, 400-mm focal length and F/6.3 optics over 3 m working distance, our results prove that a sophisticated coding design scheme plus homogeneous enrollment/testing setups can effectively overcome the blurring caused by phase modulation and omit Wiener-based restoration. In our experiments, which are based on 3328 iris images in total, the EDoF factor can achieve a result 3.71 times better than the original system without a loss of recognition accuracy.

  5. Security enhanced BioEncoding for protecting iris codes

    Science.gov (United States)

    Ouda, Osama; Tsumura, Norimichi; Nakaguchi, Toshiya

    2011-06-01

    Improving the security of biometric template protection techniques is a key prerequisite for the widespread deployment of biometric technologies. BioEncoding is a recently proposed template protection scheme, based on the concept of cancelable biometrics, for protecting biometric templates represented as binary strings such as iris codes. The main advantage of BioEncoding over other template protection schemes is that it does not require user-specific keys and/or tokens during verification. Besides, it satisfies all the requirements of the cancelable biometrics construct without deteriorating the matching accuracy. However, although it has been shown that BioEncoding is secure enough against simple brute-force search attacks, the security of BioEncoded templates against more smart attacks, such as record multiplicity attacks, has not been sufficiently investigated. In this paper, a rigorous security analysis of BioEncoding is presented. Firstly, resistance of BioEncoded templates against brute-force attacks is revisited thoroughly. Secondly, we show that although the cancelable transformation employed in BioEncoding might be non-invertible for a single protected template, the original iris code could be inverted by correlating several templates used in different applications but created from the same iris. Accordingly, we propose an important modification to the BioEncoding transformation process in order to hinder attackers from exploiting this type of attacks. The effectiveness of adopting the suggested modification is validated and its impact on the matching accuracy is investigated empirically using CASIA-IrisV3-Interval dataset. Experimental results confirm the efficacy of the proposed approach and show that it preserves the matching accuracy of the unprotected iris recognition system.

  6. Driving Simulator study for intelligent cooperative intersection safety system (IRIS)

    NARCIS (Netherlands)

    Vreeswijk, J.; Schendzielorz, T.; Mathias, P.; Feenstra, P.

    2008-01-01

    About forty percent of all accidents occur at intersections. The Intelligent Cooperative Intersection Safety system (IRIS), as part of the European research project SAFESPOT, is a roadside application and aims at minimizing the number of accidents at controlled and uncontrolled intersections. IRIS

  7. A High-Gradient Test of a 30 GHz Molybdenum-Iris Structure

    CERN Document Server

    Wuensch, Walter; Braun, H; Carron, G; Corsini, R; Döbert, Steffen; Fandos, R; Grudiev, A; Jensen, E; Mete, Ö; Ramsvik, T; Rodríguez, José Alberto; Sladen, Jonathan P H; Syratchev, I V; Taborelli, M; Tecker, F A; Urschütz, Peter; Wilson, Ian H; CERN. Geneva

    2006-01-01

    The CLIC study is actively investigating a number of different materials in an effort to find ways to increase achievable accelerating gradient. So far a series of rf tests have been made with a set of identical-geometry structures: a W-iris 30 GHz structure, a Mo-iris 30 GHz structure (with pulses as long as 16 ns) and a scaled Mo-iris X-band structure. A second Mo-iris 30 GHz structure of the same geometry has now been tested in CTF3 with pulse lengths up to 350 ns. The structure was conditioned to a gradient of 140 MV/m with a 70 ns pulse length and a breakdown rate slope of 13 MV/m per decade has been measured

  8. Developing virtual REU cohorts: Reflections from the IRIS Undergraduate Internship Program

    Science.gov (United States)

    Hubenthal, M.; Taber, J.; Aster, R.; Frassetto, A.

    2007-12-01

    Beginning in 2006, the IRIS Education and Outreach program received funding from the National Science Foundation (EAR-0453427) to explore a novel approach to the traditional Research Experience for Undergraduates (REU) model. This model blends the spirit of an REU program, which traditionally hosts participants in one location with successful prior IRIS experience hosting students at widely separated institutions to participate in summer research. A unique feature the IRIS Undergraduate Internship Program is that throughout the summer, interns form and sustain a virtual community, offering assistance, sharing ideas, asking questions, and relaying life experiences while conducting their research at diverse institutions. Key to IRIS's REU model is a combination of: one-on-one mentoring by researchers at IRIS institutions across the US, developing a strong unity among interns through both face-to-face and on-line interactions, participation of an IRIS REU alumni mentor to provide both group and intern-specific guidance developing interns' abilities to self-evaluate and work independently, through carefully designed web-based tools, and increasing interns' awareness of the IRIS and broader Earth Science community; demonstrating the role they will play in this larger community. Virtual interaction is facilitated by 1) bringing students together for face-to-face contact, through a week long orientation held annually at the IRIS PASSCAL Instrument Center on the campus of the New Mexico Institute of Mining and Technology, and 2) the community enabling web infrastructure at http://www.iris.edu/internship/. During the orientation students engage in classes in geophysics basics, career preparation, as well as training to communicate virtually. Our experiences and evaluations from the 2006 and 2007 field seasons have:shown the increasing demand for electronic advertising of REU programs, provided support for several assumptions of the model including the key role of both the

  9. Nuclear power desalinating complex with IRIS reactor plant and Russian distillation desalinating unit

    International Nuclear Information System (INIS)

    Kostin, V. I.; Panov, Yu.K.; Polunichev, V. I.; Fateev, S. A.; Gureeva, L. V.

    2004-01-01

    This paper has been prepared as a result of Russian activities on the development of nuclear power desalinating complex (NPDC) with the IRIS reactor plant (RP). The purpose of the activities was to develop the conceptual design of power desalinating complex (PDC) and to evaluate technical and economical indices, commercial attractiveness and economical efficiency of PDC based on an IRIS RP with distillation desalinating plants. The paper presents the main results of studies as applied to dual-purpose PDC based on IRIS RP with different types of desalinating plants, namely: characteristics of nuclear power desalinating complex based on IRIS reactor plant using Russian distillation desalinating technologies; prospective options of interface circuits of the IRIS RP with desalinating plants; evaluations of NPDC with IRIS RP output based on selected desalinating technologies for water and electric power supplied to the grid; cost of water generated by NPDC for selected interface circuits made by the IAEA DEEP code as well as by the Russian TEO-INVEST code; cost evaluation results for desalinated water of PDC operating on fossil fuel and conditions for competitiveness of the nuclear PDC based on IRIS RP compared with analog desalinating complexes operating on fossil fuel.(author)

  10. On the Origin of the Flare Emission in IRIS ’ SJI 2832 Filter:Balmer Continuum or Spectral Lines?

    Energy Technology Data Exchange (ETDEWEB)

    Kleint, Lucia; Krucker, Säm [University of Applied Sciences and Arts Northwestern Switzerland, Bahnhofstrasse 6, 5210 Windisch (Switzerland); Heinzel, Petr [Astronomical Institute, The Czech Academy of Sciences, Fričova 298, 25165 Ondřejov (Czech Republic)

    2017-03-10

    Continuum (“white-light,” WL) emission dominates the energetics of flares. Filter-based observations, such as the IRIS SJI 2832 filter, show WL-like brightenings during flares, but it is unclear whether the emission arises from real continuum emission or enhanced spectral lines, possibly turning into emission. The difficulty in filter-based observations, contrary to spectral observations, is to determine which processes contribute to the observed brightening during flares. Here we determine the contribution of the Balmer continuum and the spectral line emission to IRIS ’ SJI 2832 emission by analyzing the appropriate passband in simultaneous IRIS NUV spectra. We find that spectral line emission can contribute up to 100% to the observed slitjaw images (SJI) emission, that the relative contributions usually temporally vary, and that the highest SJI enhancements that are observed are most likely because of the Balmer continuum. We conclude that care should be taken when calling SJI 2832 a continuum filter during flares, because the influence of the lines on the emission can be significant.

  11. On the Origin of the Flare Emission in IRIS ’ SJI 2832 Filter:Balmer Continuum or Spectral Lines?

    International Nuclear Information System (INIS)

    Kleint, Lucia; Krucker, Säm; Heinzel, Petr

    2017-01-01

    Continuum (“white-light,” WL) emission dominates the energetics of flares. Filter-based observations, such as the IRIS SJI 2832 filter, show WL-like brightenings during flares, but it is unclear whether the emission arises from real continuum emission or enhanced spectral lines, possibly turning into emission. The difficulty in filter-based observations, contrary to spectral observations, is to determine which processes contribute to the observed brightening during flares. Here we determine the contribution of the Balmer continuum and the spectral line emission to IRIS ’ SJI 2832 emission by analyzing the appropriate passband in simultaneous IRIS NUV spectra. We find that spectral line emission can contribute up to 100% to the observed slitjaw images (SJI) emission, that the relative contributions usually temporally vary, and that the highest SJI enhancements that are observed are most likely because of the Balmer continuum. We conclude that care should be taken when calling SJI 2832 a continuum filter during flares, because the influence of the lines on the emission can be significant.

  12. A modified COMS plaque for iris melanoma

    Directory of Open Access Journals (Sweden)

    Daniel J. Scanderbeg

    2011-09-01

    Full Text Available Melanoma of the iris is a rare condition compared to posterior ocular tumors and in this case report we presenta 51-year-old female patient with diffuse iris melanoma. Traditional COMS (Collaborative Ocular Melanoma Studyplaques are used at our institution for radiation therapy, so a novel modification of the traditional plaque was requiredto allow better conformance with placement on the cornea. The usual silastic insert was machined to dimensions incompliance with the cornea, placed without incident, and treatment delivered with excellent patient tolerance of themodified plaque.

  13. Expression of defender against apoptotic death (DAD-1) in iris and dianthus petals

    NARCIS (Netherlands)

    Kop, van der D.A.M.; Ruys, G.; Dees, D.; Schoot, van der C.; Boer, de A.D.; Doorn, van W.G.

    2003-01-01

    The gene defender against apoptotic death (DAD-1) prevents programmed cell death in animal cells. We investigated the expression pattern of DAD-1 in petals of iris (Iris x hollandica cv. Blue Magic) and carnation (Dianthus caryophyllus cv. Etarro). DAD-1 expression in Iris petals was strongly

  14. Systematic Re-evaluation of Iris atrofusca Baker (Sawsan Jela'd) of Shafa Badran in Jordan as Iris nigricans Dinsmore

    International Nuclear Information System (INIS)

    Oran, S.; AL-Da'ja, I.

    2003-01-01

    The identity of one species of Iris (Iridaceae) from Locality at Shafa Badran area in Amman/Jordan has been reassessed and reidentified as I.nigricans Dinsmore, the national flower of Jordan, as it is misidentified as I. atrofusca for plants collected and identified from this area previously and as recorded in the related literature ( Post, 1932; Feinbrun, 1986). This decision has been made on the basis of studying fresh plants collected from Shafa Badran area, northeast of Amman in the period March-April 2001. The confirmation of identity of the species of Iris occur in Shafa Badran was based on studying the morphological characteristics of the leaves ,stems flowers for plants collected from that area, as well as studying the pollen grains and seed characteristics using light and scanning electron microscopy, as compared with plants of Iris nigricans collected from Madaba area for the same characters. Moreover, herbarium specimens deposited st Amman herbarium were checked and reidentified as I. nigricans. The results of studying the vegetative reproductive characters suggesting that the species that is occurring in Shafa Badran area is I.nigricans. However, these findings suggest that an interbreeding might have taken place between the individuals of I. nigricans in Shafa Badran and I.atrofusca from a neighboring geographical area called Jarash in North of Jordan, close enough that they are not geographically isolated for specimens that were probably intermixed with the population of Iris nigricans in Shafa Badran area. ( authors)

  15. Thirty Years of Innovation in Seismology with the IRIS Consortium

    Science.gov (United States)

    Sumy, D. F.; Woodward, R.; Aderhold, K.; Ahern, T. K.; Anderson, K. R.; Busby, R.; Detrick, R. S.; Evers, B.; Frassetto, A.; Hafner, K.; Simpson, D. W.; Sweet, J. R.; Taber, J.

    2015-12-01

    The United States academic seismology community, through the National Science Foundation (NSF)-funded Incorporated Research Institutions for Seismology (IRIS) Consortium, has promoted and encouraged a rich environment of innovation and experimentation in areas such as seismic instrumentation, data processing and analysis, teaching and curriculum development, and academic science. As the science continually evolves, IRIS helps drive the market for new research tools that enable science by establishing a variety of standards and goals. This has often involved working directly with manufacturers to better define the technology required, co-funding key development work or early production prototypes, and purchasing initial production runs. IRIS activities have helped establish de-facto international standards and impacted the commercial sector in areas such as seismic instrumentation, open-access data management, and professional development. Key institutional practices, conducted and refined over IRIS' thirty-year history of operations, have focused on open-access data availability, full retention of maximum-bandwidth, continuous data, and direct community access to state-of-the-art seismological instrumentation and software. These practices have helped to cultivate and support a thriving commercial ecosystem, and have been a key element in the professional development of multiple generations of seismologists who now work in both industry and academia. Looking toward the future, IRIS is increasing its engagement with industry to better enable bi-directional exchange of techniques and technology, and enhancing the development of tomorrow's workforce. In this presentation, we will illustrate how IRIS has promoted innovations grown out of the academic community and spurred technological advances in both academia and industry.

  16. IRIS: A SIGNIFICANT ELEMENT OF THE MEDITERRANEAN LANDSCAPE

    OpenAIRE

    A. UBRIZSY SAVOIA; S. PIGNATTI; S. VAROLI PIAZZA

    2000-01-01

    The Southern European species of Iris growing in dry, rocky places, stony ground, terra rossa, sandy, basalt and/or calcareous hills, maquis and coastal rocky slopes, are a neglected bioplasm resource of the Mediterranean landscape. These species have traditional uses and cultural significance and have inspired artists. Both natural and naturalised ornamental Iris species may help to improve and maintain the Mediterranean landscape by avoiding land erosion, fixing dunes and preserving coastal...

  17. Computational model for transient studies of IRIS pressurizer behavior

    International Nuclear Information System (INIS)

    Rives Sanz, R.; Montesino Otero, M.E.; Gonzalez Mantecon, J.; Rojas Mazaira, L.

    2014-01-01

    International Reactor Innovative and Secure (IRIS) excels other Small Modular Reactor (SMR) designs due to its innovative characteristics regarding safety. IRIS integral pressurizer makes the design of larger pressurizer system than the conventional PWR, without any additional cost. The IRIS pressurizer volume of steam can provide enough margins to avoid spray requirement to mitigate in-surge transient. The aim of the present research is to model the IRIS pressurizer's dynamic using the commercial finite volume Computational Fluid Dynamic code CFX 14. A symmetric tridimensional model equivalent to 1/8 of the total geometry was adopted to reduce mesh size and minimize processing time. The model considers the coexistence of three phases: liquid, steam, and vapor bubbles in liquid volume. Additionally, it takes into account the heat losses between the pressurizer and primary circuit. The relationships for interfacial mass, energy, and momentum transport are programmed and incorporated into CFX by using expressions in CFX Command Language (CCL) format. Moreover, several additional variables are defined for improving the convergence and allow monitoring of boron dilution sequences and condensation-evaporation rate in different control volumes. For transient states a non - equilibrium stratification in the pressurizer is considered. This paper discusses the model developed and the behavior of the system for representative transients sequences such as the in/out-surge transients and boron dilution sequences. The results of analyzed transients of IRIS can be applied to the design of pressurizer internal structures and components. (author)

  18. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5 ...

    Science.gov (United States)

    The IRIS Toxicological Review of Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) was released for external peer review in September 2016. The EPA’s Science Advisory Board’s (SAB) Chemical Assessment Advisory Committee (CAAC) will conduct a peer review of the scientific basis supporting the RDX assessment and release a final report of their review. Information regarding the peer review can be found on the SAB website. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for RDX. The outcome of this project is an updated Toxicological Review and IRIS Summary for RDX that will be entered into the IRIS database.

  19. Koira-avusteinen terapia lasten psyykkisten häiriöiden hoidossa

    OpenAIRE

    Tuovinen, Susanna

    2014-01-01

    Tuovinen, Susanna. Koira-avusteinen terapia lasten psyykkisten häiriöiden hoidossa. Kevät 2014. 61 sivua, 1 liite. Diakonia-ammattikorkeakoulu, Hoitotyön koulutusohjelma, Sairaanhoitaja (AMK). Koira-avusteinen psykoterapia on maailmalla tunnettu hoitomuoto psyykkisten häiriöiden hoidossa. Suomessa se ei kuitenkaan ole vielä saavuttanut samanlaista suosiota. Tämä opinnäytetyö kertoo koira-avusteisesta terapiasta ja sen käytöstä yhtenä lasten psyykkisten häiriöiden hoitomuotona. O...

  20. Grading of Iris Color with an Extended Photographic Reference Set

    Directory of Open Access Journals (Sweden)

    Luuk Franssen

    2008-01-01

    Conclusion: The new method is promising to be more accurate than existing iris color classification systems in clinical situations where objective colorimetry-based systems are not available. The method may be useful to assess iris translucency and fundus reflectance as sources of variation in retinal straylight.

  1. Customized surgical template fabrication under biomechanical consideration by integrating CBCT image, CAD system and finite element analysis.

    Science.gov (United States)

    Yu, Jian-Hong; Wang, Yu-Tzu; Lin, Chun-Li

    2018-01-30

    This study developed a customized surgical template under mechanical consideration for molar intrusion. Two finite element (FE) models were analyzed for the primary stability under 100 gf traction forces with one mini-screw inserted at the buccal side in horizontal and another in palatal side with two optional positions at 60° (P60) or 15° (P15) angles with inclination toward the molar occlusal surface. The surgical template was generated using rapid prototyping (RP) printing for the clinical application based on improved primarily stability model. The surrounding bone strains for models P15 and P60 were far lower than the bone remodeling critical value. Model P60 presented much lower micro-motion in the screw/bone interface and the screw head displacement than those values in model P15. Using FE analysis for biomechanical evaluation and combining with CT image, image superimposed method and CAD technique can fabricate accuracy/security customized surgical template for mini-screws with better primary stability.

  2. The IRIS Data Management Center: Enabling Access to Observational Time Series Spanning Decades

    Science.gov (United States)

    Ahern, T.; Benson, R.; Trabant, C.

    2009-04-01

    The Incorporated Research Institutions for Seismology (IRIS) is funded by the National Science Foundation (NSF) to operate the facilities to generate, archive, and distribute seismological data to research communities in the United States and internationally. The IRIS Data Management System (DMS) is responsible for the ingestion, archiving, curation and distribution of these data. The IRIS Data Management Center (DMC) manages data from more than 100 permanent seismic networks, hundreds of temporary seismic deployments as well as data from other geophysical observing networks such as magnetotelluric sensors, ocean bottom sensors, superconducting gravimeters, strainmeters, surface meteorological measurements, and in-situ atmospheric pressure measurements. The IRIS DMC has data from more than 20 different types of sensors. The IRIS DMC manages approximately 100 terabytes of primary observational data. These data are archived in multiple distributed storage systems that insure data availability independent of any single catastrophic failure. Storage systems include both RAID systems of greater than 100 terabytes as well as robotic tape robots of petabyte capacity. IRIS performs routine transcription of the data to new media and storage systems to insure the long-term viability of the scientific data. IRIS adheres to the OAIS Data Preservation Model in most cases. The IRIS data model requires the availability of metadata describing the characteristics and geographic location of sensors before data can be fully archived. IRIS works with the International Federation of Digital Seismographic Networks (FDSN) in the definition and evolution of the metadata. The metadata insures that the data remain useful to both current and future generations of earth scientists. Curation of the metadata and time series is one of the most important activities at the IRIS DMC. Data analysts and an automated quality assurance system monitor the quality of the incoming data. This insures data

  3. 76 FR 13402 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2011-03-11

    ... Information System (IRIS); Announcement of Availability of Literature Searches for IRIS Assessments AGENCY: Environmental Protection Agency. ACTION: Announcement of availability of literature searches for IRIS... the availability of literature searches for cobalt (CASRN 7440-48-4) and inorganic cobalt compounds...

  4. 77 FR 20817 - Integrated Risk Information System (IRIS); Announcement of Availability of Literature Searches...

    Science.gov (United States)

    2012-04-06

    ... System (IRIS); Announcement of Availability of Literature Searches for IRIS Assessments AGENCY: Environmental Protection Agency. ACTION: Announcement of availability of literature searches for IRIS... the availability of literature searches for acetaldehyde (75-07-0) and 1,2,3-trimethlybenzene (526-73...

  5. BRCA1-IRIS regulates cyclin D1 expression in breast cancer cells

    International Nuclear Information System (INIS)

    Nakuci, Enkeleda; Mahner, Sven; DiRenzo, James; ElShamy, Wael M.

    2006-01-01

    The regulator of cell cycle progression, cyclin D1, is up-regulated in breast cancer cells; its expression is, in part, dependent on ERα signaling. However, many ERα-negative tumors and tumor cell lines (e.g., SKBR3) also show over-expression of cyclin D1. This suggests that, in addition to ERα signaling, cyclin D1 expression is under the control of other signaling pathways; these pathways may even be over-expressed in the ERα-negative cells. We previously noticed that both ERα-positive and -negative cell lines over-express BRCA1-IRIS mRNA and protein. Furthermore, the level of over-expression of BRCA1-IRIS in ERα-negative cell lines even exceeded its over-expression level in ERα-positive cell lines. In this study, we show that: (1) BRCA1-IRIS forms complex with two of the nuclear receptor co-activators, namely, SRC1 and SRC3 (AIB1) in an ERα-independent manner. (2) BRCA1-IRIS alone, or in connection with co-activators, is recruited to the cyclin D1 promoter through its binding to c-Jun/AP1 complex; this binding activates the cyclin D1 expression. (3) Over-expression of BRCA1-IRIS in breast cells over-activates JNK/c-Jun; this leads to the induction of cyclin D1 expression and cellular proliferation. (4) BRCA1-IRIS activation of JNK/c-Jun/AP1 appears to account for this, because in cells that were depleted from BRCA1-IRIS, JNK remained inactive. However, depletion of SRC1 or SRC3 instead reduced c-Jun expression. Our data suggest that this novel signaling pathway links BRCA1-IRIS to cellular proliferation through c-Jun/AP1 nuclear pathway; finally, this culminates in the increased expression of the cyclin D1 gene

  6. Template characterization and correlation algorithm created from segmentation for the iris biometric authentication based on analysis of textures implemented on a FPGA

    International Nuclear Information System (INIS)

    Giacometto, F J; Vilardy, J M; Torres, C O; Mattos, L

    2011-01-01

    Among the most used biometric signals to set personal security permissions, taker increasingly importance biometric iris recognition based on their textures and images of blood vessels due to the rich in these two unique characteristics that are unique to each individual. This paper presents an implementation of an algorithm characterization and correlation of templates created for biometric authentication based on iris texture analysis programmed on a FPGA (Field Programmable Gate Array), authentication is based on processes like characterization methods based on frequency analysis of the sample, and frequency correlation to obtain the expected results of authentication.

  7. Test of the Practicality and Feasibility of EDoF-Empowered Image Sensors for Long-Range Biometrics

    Directory of Open Access Journals (Sweden)

    Sheng-Hsun Hsieh

    2016-11-01

    Full Text Available For many practical applications of image sensors, how to extend the depth-of-field (DoF is an important research topic; if successfully implemented, it could be beneficial in various applications, from photography to biometrics. In this work, we want to examine the feasibility and practicability of a well-known “extended DoF” (EDoF technique, or “wavefront coding,” by building real-time long-range iris recognition and performing large-scale iris recognition. The key to the success of long-range iris recognition includes long DoF and image quality invariance toward various object distance, which is strict and harsh enough to test the practicality and feasibility of EDoF-empowered image sensors. Besides image sensor modification, we also explored the possibility of varying enrollment/testing pairs. With 512 iris images from 32 Asian people as the database, 400-mm focal length and F/6.3 optics over 3 m working distance, our results prove that a sophisticated coding design scheme plus homogeneous enrollment/testing setups can effectively overcome the blurring caused by phase modulation and omit Wiener-based restoration. In our experiments, which are based on 3328 iris images in total, the EDoF factor can achieve a result 3.71 times better than the original system without a loss of recognition accuracy.

  8. Survey of virus pathogens in gladiolus, iris and tulips in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Ganesh Selvaraj Duraisamy

    2009-01-01

    Full Text Available The occurrence of Bean yellow mosaic virus (BYMV, Cucumber mosaic virus (CMV Tobacco rattle virus (TRV in gladiolus, iris, tulip and Iris yellow spot virus (IYSV in iris was investigated by examining the plants by the means of serological techniques (ELISA. ELISA was applied to determine the presence of BYMV, CMV, TRV infections in both aerial and underground parts of gladiolus, iris, and tulip, and IYSV on the aerial parts of iris, respectively. 262 gladiolus plants were tested. 63.7% was infected by BYMV, 29.4 % by CMV, and 2.7 % by TRV. Out of 180 plants of iris, 1.1% was infected by BYMV, 6.7% by CMV, 2.8% by TRV, and 0% by IYSV. Out of 28 plants of tulip, 28.6% was infected by CMV, and 7.1% by TRV. ELISA proved to be a suitable method for detection of viruses in leaves of these ornamental plants, but it often failed to detect viruses in flowers and corms. A high transmission of BYMV by gladiolus cormlets was also found.

  9. Iris colour in relation to myopia among Chinese school-aged children.

    Science.gov (United States)

    Pan, Chen-Wei; Qiu, Qin-Xiao; Qian, Deng-Juan; Hu, Dan-Ning; Li, Jun; Saw, Seang-Mei; Zhong, Hua

    2018-01-01

    Understanding the association of iris colour and myopia may provide further insights into the role of the wavelength of lights in the pathophysiology of myopia. We aim to assess the association of iris colour and myopia in a school-based sample of Chinese students. Two thousand three hundred and forty-six Year 7 students from 10 middle schools (93.5% response rate) aged 13-14 years in Mojiang, a small county located in Southwestern China, participated in the study. We obtained standardised slit lamp photographs and developed a grading system assessing iris colour (higher grade denoting a darker iris). Refractive error was measured after cycloplegia using an autorefractor by optometrists or trained technicians. An IOLMaster (www.zeiss.com) was used to measure ocular biometric parameters including axial length (AL). Of all the study participants, 693 (29.5%) were affected by myopia with the prevalence estimates being higher in girls (36.8%; 95% confidence interval [CI]: 34.0, 39.6) than in boys (22.8%; 95% CI: 20.4, 25.1) (p iris colour tended to have a higher prevalence of myopia, a more myopic refraction and a longer AL. Dose-response relationships were observed in all regression models (p for trend iris colour was associated with more myopic refractive errors and longer ALs among Chinese school-aged children and this association was independent of other known myopia-related risk factors. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  10. Genetic and phenotypic variability of iris color in Buenos Aires population

    Directory of Open Access Journals (Sweden)

    Diana María Hohl

    Full Text Available Abstract The aim of this work was to describe the phenotypic and genotypic variability related to iris color for the population of Buenos Aires province (Argentina, and to assess the usefulness of current methods of analysis for this country. We studied five Single Nucleotide Polymorphisms (SNPs included in the IrisPlex kit, in 118 individuals, and we quantified eye color with Digital Iris Analysis Tool. The markers fit Hardy-Weinberg equilibrium for the whole sample, but not for rs12913832 within the group of brown eyes (LR=8.429; p=0.004. We found a remarkable association of HERC2 rs12913832 GG with blue color (p < 0.01 but the other markers did not show any association with iris color. The results for the Buenos Aires population differ from those of other populations of the world for these polymorphisms (p < 0,01. The differences we found might respond to the admixed ethnic composition of Argentina; therefore, methods of analysis used in European populations should be carefully applied when studying the population of Argentina. These findings reaffirm the importance of this investigation in the Argentinian population for people identification based on iris color.

  11. Iris en sayuela signo clínico nuevo asociado al síndrome tóxico del segmento anterior: a new clinical sign associated to the anterior segment toxic syndrome Iris in underskirt

    Directory of Open Access Journals (Sweden)

    Iván Hernández López

    2010-01-01

    Full Text Available OBJETIVO: Presentar un nuevo signo clínico como resultado del desprendimiento gigante del epitelio pigmentado posterior del iris en el curso de un síndrome tóxico del segmento anterior tras una cirugía de catarata. MÉTODOS: Presentamos un paciente intervenido de catarata mediante facoemulsificación con implante de lente intraocular de cámara posterior plegable, sin incidencias ni complicaciones transoperatorias. Se le realizó evaluación biomicroscópica en el posoperatorio inmediato diagnosticándosele un síndrome tóxico del segmento anterior asociado a un desprendimiento gigante del epitelio pigmentado posterior del iris. Se tomaron fotos durante la evolución del paciente para documentar este raro signo clínico. RESULTADOS: Al provocar la dilatación pupilar farmacológica nos encontramos con la retracción de todas las capas anteriores del iris, mostrando por debajo al epitelio pigmentado posterior del iris sinequiado al lente intraocular y tan extensamente desprendido que simulaba un segundo iris. No encontramos este hallazgo clínico reportado en la literatura revisada. Denominamos este signo como iris en sayuela. CONCLUSIONES: El desprendimiento del epitelio pigmentado posterior del iris constituye un hallazgo clínico que puede aparecer raramente asociado al síndrome tóxico del segmento anterior y cuando es muy extenso puede presentarse de forma insólita como el signo del iris en sayuela.OBJECTIVE: To present a new clinical sign as a result of a huge posterior pigmented epithelium detachment of the iris in the course of at toxic anterior segment syndrome after a successful cataract surgery. METHOD: A patient who had undergone a cataract surgery by phacoemulsification with posterior chamber foldable intraocular lens implantation, without any incidence or transoperative complication. He was evaluated through biomicroscopy in the immediate postoperative period where a huge posterior pigmented epithelium detachment of the iris

  12. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  13. IRIS Toxicological Review of 2-Hexanone (External Review ...

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of 2-hexanone that will appear on the Integrated Risk Information System (IRIS) database. Peer review is meant to ensure that science is used credibly and appropriately in derivation of the dose-response assessments and toxicological characterization. 2-Hexanone was nominated for IRIS assessment because of its frequent detection at sites nation-wide and its occurrence as a byproduct of certain industrial processes.

  14. Analysis of the Variables that Affect Bookstore Customer Satisfaction

    Directory of Open Access Journals (Sweden)

    Elis Ratna Wulan

    2016-02-01

    Full Text Available Competition, which becomes more widespread, complex, and intense, drives companies to must be able to see the various opportunities that exist and to identify strategies for creating customer satisfaction. As an example of a company must be able to produce products with good quality, reasonable price, facilities, and companies are able to create a positive image in the eyes of consumers. This strategy is quite important in facing the competitive level of competition with rival firms. This research is aimed to analysis simultaneously or partially positive effect of the facilities, prices and corporate image on customer satisfaction, as well as analyzing the most dominant variable in effecting bookstore customer satisfaction. Data used in this research are primary data from Tmbookstore customer in Cianjur city, West Java Indonesia, which were collected from respondents using valid and reliable questionnaire. A total of 100 respondents were selected from Tmbookstore visitors by accidental sampling. Data were analyzed using multiple regression analysis. Results of the research indicate that product, price, location, and simultaneously affect to bookstore consumer satisfaction. Partially, only two of the three variables that affect bookstore consumer satisfaction namely price and company image. Image of the company is the most a dominant impact on bookstore customer satisfaction.

  15. Analysis of the Variables that Affect Bookstore Customer Satisfaction

    Directory of Open Access Journals (Sweden)

    Elis Ratna Wulan

    2015-06-01

    Full Text Available Competition, which becomes more widespread, complex, and intense, drives companies to must be able to see the various opportunities that exist and to identify strategies for creating customer satisfaction. As an example of a company must be able to produce products with good quality, reasonable price, facilities, and companies are able to create a positive image in the eyes of consumers. This strategy is quite important in facing the competitive level of competition with rival firms. This research is aimed to analysis simultaneously or partially positive effect of the facilities, prices and corporate image on customer satisfaction, as well as analyzing the most dominant variable in effecting bookstore customer satisfaction.  Data used in this research are primary data from Tmbookstore customer in Cianjur city, West Java Indonesia, which were collected from respondents using valid and reliable questionnaire. A total of 100 respondents were selected from Tmbookstore visitors by accidental sampling. Data were analyzed using multiple regression analysis. Results of the research indicate that product, price, location, and simultaneously affect to bookstore consumer satisfaction. Partially, only two of the three variables that affect bookstore consumer satisfaction namely price and company image. Image of the company is the most a dominant impact on bookstore customer satisfaction.

  16. Improving Robustness Assessment Methodologies for Structures Impacted by Missiles (IRIS-2012) - Final Report

    International Nuclear Information System (INIS)

    Orbovic, Neb; Blahoainu, Andrei; Sagals, Genadis; Tarallo, Francois; Rambach, Jean-Mathieu; Huerta, Alejandro; White, Andrew; Nevander, Olli; ); Riera, Jorge Daniel; Krauthammer, Ted; Krutzik, Norbert; Arros, Jorma; Rouqand, Alain; Stangenberg, Friedhelm; Schwer, Leonard E.

    2014-01-01

    This report documents the results and conclusions of the second phase of the Integrity and Ageing of Components and Structures Working Group (WGIAGE) activity 'Improving Robustness assessment of structures Impacted by missiles', called IRIS-2012. The objective of the activity was to conduct a post-test benchmark study to improve models and evaluation techniques used in IRIS-2010. The benchmark was open to the new participants and some of IRIS-2010 participants did not take part of IRIS-2012. For this reason the team numbers in two benchmarks are different and to make direct comparisons it is necessary to have both lists. For IRIS-2010 benchmark a series of repeated test was performed: two bending rupture tests and three punching rupture tests. For IRIS-2012 and based on recommendation from IRIS-2010, tri-axial tests and Brazilian tensile test were additionally performed in order to calibrate constitutive models. The benchmark was officially launched in February 2012 with the participation of twenty six teams from twenty different institutions (Safety Authorities, TSOs, Utilities, Vendors, Research Institutes and Consulting Companies), from ten different countries from Europe, North America and Asia (plus 1 international organisation). A three day workshop was convened in October 2012 in Ottawa, Ontario, Canada where each participating team presented and discussed their results and performed simulations. Based on IRIS-2010 results and recommendations, OECD/NEA members recognized that there was a need to continue the work on understanding and improving simulation of structural impact. The goal of the new IRIS-2012 benchmark was to: 1) Update and improve existing FE models, for teams that participated in IRIS-2010, or to create new models for new participants. In order to improve FE models it was requested to: Simulate uni-axial unconfined concrete test and tri-axial concrete tests, using the results provided by IRSN, as well as the Brazilian test (concrete tensile

  17. Iris coloboma in one eye and pigment dispersion syndrome in the fellow eye.

    Science.gov (United States)

    Galvis, Virgilio; Tello, Alejandro; Valarezo, Paul; Prada, Angélica M

    2013-05-22

    We report a case of a 43-year-old patient with coloboma of the iris, zonule, ciliary body, choroid and retina in the right eye and pigment dispersion syndrome in the left eye. Considering the hypothesis of the pigment dispersion syndrome pathogenesis in which a difference of pressures in the anterior and posterior chambers creates a posterior convexity of the iris leading to reverse pupillary block, iris touch and consequently causing pigment dispersion, we suggest that the presence of an iris coloboma, by equalising the pressures in the two chambers, prevented the onset of syndrome in that eye.

  18. Motions in Prominence Barbs as observed by Hinode/SOT and IRIS

    Science.gov (United States)

    Kucera, Therese A.; Ofman, Leon; Tarbell, Theodore D.

    2016-05-01

    We discuss observations of prominence barb dynamics as observed by Hinode/SOT and IRIS. Prominence barbs extend outwards to the side of the main prominence spine and downwards towards the chromosphere. Their properties, including the structure of their magnetic field and the nature of the motions observed in them are a subject of current debate. We use a combination of high cadence, high resolution imaging, H-alpha Doppler, and Mg II line profile data to analyze and understand waves and flows in barbs and discuss their ramifications in terms of a model of the barb magnetic field as collection of dipped field lines.

  19. SU-E-T-59: Calculations of Collimator Scatter Factors (Sc) with and Without Custom-Made Build-Up Caps for CyberKnife

    Energy Technology Data Exchange (ETDEWEB)

    Wokoma, S; Yoon, J; Jung, J [East Carolina University, Greenville, NC (United States); Lee, S [Rhode Island Hospital / Warren Alpert Medical, Providence, RI (United States)

    2014-06-01

    Purpose: To investigate the impact of custom-made build-up caps for a diode detector in robotic radiosurgery radiation fields with variable collimator (IRIS) for collimator scatter factor (Sc) calculation. Methods: An acrylic cap was custom-made to fit our SFD (IBA Dosimetry, Germany) diode detector. The cap has thickness of 5 cm, corresponding to a depth beyond electron contamination. IAEA phase space data was used for beam modeling and DOSRZnrc code was used to model the detector. The detector was positioned at 80 cm source-to-detector distance. Calculations were performed with the SFD, with and without the build-up cap, for clinical IRIS settings ranging from 7.5 to 60 mm. Results: The collimator scatter factors were calculated with and without 5 cm build-up cap. They were agreed within 3% difference except 15 mm cone. The Sc factor for 15 mm cone without buildup was 13.2% lower than that with buildup. Conclusion: Sc data is a critical component in advanced algorithms for treatment planning in order to calculate the dose accurately. After incorporating build-up cap, we discovered differences of up to 13.2 % in Sc factors in the SFD detector, when compared against in-air measurements without build-up caps.

  20. An improved triangulation laser rangefinder using a custom CMOS HDR linear image sensor

    Science.gov (United States)

    Liscombe, Michael

    3-D triangulation laser rangefinders are used in many modern applications, from terrain mapping to biometric identification. Although a wide variety of designs have been proposed, laser speckle noise still provides a fundamental limitation on range accuracy. These works propose a new triangulation laser rangefinder designed specifically to mitigate the effects of laser speckle noise. The proposed rangefinder uses a precision linear translator to laterally reposition the imaging system (e.g., image sensor and imaging lens). For a given spatial location of the laser spot, capturing N spatially uncorrelated laser spot profiles is shown to improve range accuracy by a factor of N . This technique has many advantages over past speckle-reduction technologies, such as a fixed system cost and form factor, and the ability to virtually eliminate laser speckle noise. These advantages are made possible through spatial diversity and come at the cost of increased acquisition time. The rangefinder makes use of the ICFYKWG1 linear image sensor, a custom CMOS sensor developed at the Vision Sensor Laboratory (York University). Tests are performed on the image sensor's innovative high dynamic range technology to determine its effects on range accuracy. As expected, experimental results have shown that the sensor provides a trade-off between dynamic range and range accuracy.

  1. THE INFLUENCE OF PRODUCT QUALITY , PRICE PERCEPTION AND BRAND IMAGE ON SATISFACTION AND CUSTOMER LOYALTY HOLCIM CONCRETE READYMIX IN JAKARTA

    OpenAIRE

    Sita Budiastari

    2016-01-01

    The purpose of this research is to find a picture of the effect of product quality , price perception and brand image on satisfaction and customer loyalty ready mix concrete in Jakarta . This research is a quantitative study with descriptive and causal methods undertaken at Holcim Beton in 2013 with a sample of 100 customers in Jakarta and its surrounding the industrial and commercial segments project . Data collection by questionnaire respondents and analyzed using path analysis with SPSS ve...

  2. An unusual case of seed dispersal in an invasive aquatic; yellow flag iris (Iris pseudacorus)

    Science.gov (United States)

    Understanding reproductive mode of invasive plants can help managers plan more efficacious control. Invasive aquatics typically reproduce primarily through vegetative means. Yellow flag iris is an invasive plant species often growing as an emergent aquatic. There have been contradictory reports of i...

  3. Do it right this time: the role of employee service recovery performance in customer-perceived justice and customer loyalty after service failures.

    Science.gov (United States)

    Liao, Hui

    2007-03-01

    Integrating justice and customer service literatures, this research examines the role of customer service employees' behaviors of handling customer complaints, or service recovery performance (SRP), in conveying a just image of service organizations and achieving desirable customer outcomes. Results from a field study and a laboratory study demonstrate that the dimensions of SRP--making an apology, problem solving, being courteous, and prompt handling--positively influenced customer satisfaction and then customer repurchase intent through the mediation of customer-perceived justice. In addition, service failure severity and repeated failures reduced the positive impact of some dimensions of SRP on customer satisfaction, and customer-perceived justice again mediated these moderated effects. (c) 2007 APA, all rights reserved.

  4. Investigation on the Influence of the Brand Image of Higher Educational Institutions on Satisfaction and Customer Lifetime Value

    Science.gov (United States)

    Wang, Cheng-Cai; Chen, Chin-Tsu; Chen, Chun-Fu

    2012-01-01

    This study aimed to discuss the relationships among the brand image of universities (external variables), university satisfaction (mediating variables) and customer lifetime value (internal variables). The findings can serve as a reference for higher educational institutions in strengthening their advantages and overcoming their shortcomings, as…

  5. Preliminary ATWS analysis for the IRIS PRA

    International Nuclear Information System (INIS)

    Maddalena Barra; Marco S Ghisu; David J Finnicum; Luca Oriani

    2005-01-01

    Full text of publication follows: The pressurized light water cooled, medium power (1000 MWt) IRIS (International Reactor Innovative and Secure) has been under development for four years by an international consortium of over 21 organizations from ten countries. The plant conceptual design was completed in 2001 and the preliminary design is nearing completion. The pre-application licensing process with NRC started in October, 2002. IRIS has been primarily focused on establishing a design with innovative safety characteristics. The first line of defense in IRIS is to eliminate event initiators that could potentially lead to core damage. In IRIS, this concept is implemented through the 'safety by design' approach, which allows to minimize the number and complexity of the safety systems and required operator actions. The end result is a design with significantly reduced complexity and improved operability, and extensive plant simplifications to enhance construction. To support the optimization of the plant design and confirm the effectiveness of the safety by design approach in mitigating or eliminating events and thus providing a significant reduction in the probability of severe accidents, the PRA is being used as an integral part of the design process. A preliminary but extensive Level 1 PRA model has been developed to support the pre-application licensing of the IRIS design. As a result of the Preliminary IRIS PRA, an optimization of the design from a reliability point of view was completed, and an extremely low (about 1.2 E -8 ) core damage frequency (CDF) was assessed to confirm the impact of the safety by design approach. This first assessment is a result of a PRA model including internal initiating events. During this assessment, several assumptions were necessary to complete the CDF evaluation. In particular Anticipated Transients Without Scram (ATWS) were not included in this initial assessment, because their contribution to core damage frequency was assumed

  6. Predictive factor analysis for successful performance of iris recognition-assisted dynamic rotational eye tracking during laser in situ keratomileusis.

    Science.gov (United States)

    Prakash, Gaurav; Ashok Kumar, Dhivya; Agarwal, Amar; Jacob, Soosan; Sarvanan, Yoga; Agarwal, Athiya

    2010-02-01

    To analyze the predictive factors associated with success of iris recognition and dynamic rotational eye tracking on a laser in situ keratomileusis (LASIK) platform with active assessment and correction of intraoperative cyclotorsion. Interventional case series. Two hundred seventy-five eyes of 142 consecutive candidates underwent LASIK with attempted iris recognition and dynamic rotational tracking on the Technolas 217z100 platform (Techolas Perfect Vision, St Louis, Missouri, USA) at a tertiary care ophthalmic hospital. The main outcome measures were age, gender, flap creation method (femtosecond, microkeratome, epi-LASIK), success of static rotational tracking, ablation algorithm, pulses, and depth; preablation and intraablation rotational activity were analyzed and evaluated using regression models. Preablation static iris recognition was successful in 247 eyes, without difference in flap creation methods (P = .6). Age (partial correlation, -0.16; P = .014), amount of pulses (partial correlation, 0.39; P = 1.6 x 10(-8)), and gender (P = .02) were significant predictive factors for the amount of intraoperative cyclodeviation. Tracking difficulties leading to linking the ablation with a new intraoperatively acquired iris image were more with femtosecond-assisted flaps (P = 2.8 x 10(-7)) and the amount of intraoperative cyclotorsion (P = .02). However, the number of cases having nonresolvable failure of intraoperative rotational tracking was similar in the 3 flap creation methods (P = .22). Intraoperative cyclotorsional activity depends on the age, gender, and duration of ablation (pulses delivered). Femtosecond flaps do not seem to have a disadvantage over microkeratome flaps as far as iris recognition and success of intraoperative dynamic rotational tracking is concerned. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  7. IRIS Toxicological Review of Ethylene Glycol Mono-Butyl ...

    Science.gov (United States)

    EPA released the draft report, Toxicological Review for Ethylene Glycol Mono-Butyl Ether , that was distributed to Federal agencies and White House Offices for comment during the Science Discussion step of the IRIS Assessment Development Process. Comments received from other Federal agencies and White House Offices are provided below with external peer review panel comments. EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of EGBE that will appear on the Integrated Risk Information System (IRIS) database.

  8. IRIS Toxicological Review of Ammonia Noncancer Inhalation (Interagency Science Discussion Draft)

    Science.gov (United States)

    In September 2016, EPA finalized the IRIS assessment of Ammonia (Noncancer Inhalation). The Toxicological Review was reviewed internally by EPA and by other federal agencies and White House Offices before public release in June 2016. Consistent with the May 2009 IRIS assessment d...

  9. Relationship between iris constitution analysis and TNF-alpha gene polymorphism in hypertensives.

    Science.gov (United States)

    Yoo, Chun-Sang; Hwang, Woo-Jun; Hong, Seung-Heon; Lee, Hye-Jung; Jeong, Hyun-Ja; Kim, Su-Jin; Kim, Hyung-Min; Um, Jae-Young

    2007-01-01

    Iridology is a complementary and alternative medicine that involves the diagnosis of medical conditions by noting irregularities of the pigmentation in the iris. Iris constitution has a strong hereditary component. Tumor necrosis factor-alpha (TNFalpha), a pleiotropic cytokine, has been implicated in many pathological processes including hypertension. In this paper, the relationship between iris constitution and TNFalpha gene polymorphism in those with hypertension is investigated. Eighty seven hypertensive individuals and 79 controls were classified according to iris constitution and the TNFalpha genotype of each individual determined. Compared to the controls, the frequency of the TNFalpha GA heterozygote was lower in the hypertensive group, although the statistical significance was marginal (p = 0.08). This result implies an association with resistance to the disease. In addition, the frequency of the cardio-renal connective tissue weakness type was significantly higher in the hypertensive group with the TNFalpha GG genotype, as compared to the controls (p = 0.001). An association is demonstrated among TNFalpha gene polymorphism, Koreans with hypertension, and iris constitution.

  10. A custom-built PET phantom design for quantitative imaging of printed distributions

    International Nuclear Information System (INIS)

    Markiewicz, P J; Angelis, G I; Kotasidis, F; Green, M; Matthews, J C; Lionheart, W R; Reader, A J

    2011-01-01

    This note presents a practical approach to a custom-made design of PET phantoms enabling the use of digital radioactive distributions with high quantitative accuracy and spatial resolution. The phantom design allows planar sources of any radioactivity distribution to be imaged in transaxial and axial (sagittal or coronal) planes. Although the design presented here is specially adapted to the high-resolution research tomograph (HRRT), the presented methods can be adapted to almost any PET scanner. Although the presented phantom design has many advantages, a number of practical issues had to be overcome such as positioning of the printed source, calibration, uniformity and reproducibility of printing. A well counter (WC) was used in the calibration procedure to find the nonlinear relationship between digital voxel intensities and the actual measured radioactive concentrations. Repeated printing together with WC measurements and computed radiography (CR) using phosphor imaging plates (IP) were used to evaluate the reproducibility and uniformity of such printing. Results show satisfactory printing uniformity and reproducibility; however, calibration is dependent on the printing mode and the physical state of the cartridge. As a demonstration of the utility of using printed phantoms, the image resolution and quantitative accuracy of reconstructed HRRT images are assessed. There is very good quantitative agreement in the calibration procedure between HRRT, CR and WC measurements. However, the high resolution of CR and its quantitative accuracy supported by WC measurements made it possible to show the degraded resolution of HRRT brain images caused by the partial-volume effect and the limits of iterative image reconstruction. (note)

  11. Super-resolution imaging of ciliary microdomains in isolated olfactory sensory neurons using a custom two-color stimulated emission depletion microscope

    Science.gov (United States)

    Meyer, Stephanie A.; Ozbay, Baris N.; Potcoava, Mariana; Salcedo, Ernesto; Restrepo, Diego; Gibson, Emily A.

    2016-06-01

    We performed stimulated emission depletion (STED) imaging of isolated olfactory sensory neurons (OSNs) using a custom-built microscope. The STED microscope uses a single pulsed laser to excite two separate fluorophores, Atto 590 and Atto 647N. A gated timing circuit combined with temporal interleaving of the different color excitation/STED laser pulses filters the two channel detection and greatly minimizes crosstalk. We quantified the instrument resolution to be ˜81 and ˜44 nm, for the Atto 590 and Atto 647N channels. The spatial separation between the two channels was measured to be under 10 nm, well below the resolution limit. The custom-STED microscope is incorporated onto a commercial research microscope allowing brightfield, differential interference contrast, and epifluorescence imaging on the same field of view. We performed immunolabeling of OSNs in mice to image localization of ciliary membrane proteins involved in olfactory transduction. We imaged Ca2+-permeable cyclic nucleotide gated (CNG) channel (Atto 594) and adenylyl cyclase type III (ACIII) (Atto 647N) in distinct cilia. STED imaging resolved well-separated subdiffraction limited clusters for each protein. We quantified the size of each cluster to have a mean value of 88±48 nm and 124±43 nm, for CNG and ACIII, respectively. STED imaging showed separated clusters that were not resolvable in confocal images.

  12. IRIS International Reactor Innovative and Secure Final Technical Progress Report

    International Nuclear Information System (INIS)

    Carelli, M.D.

    2003-01-01

    OAK-B135 This NERI project, originally started as the Secure Transportable Autonomous Light Water Reactor (STAR-LW) and currently known as the International Reactor Innovative and Secure (IRIS) project, had the objective of investigating a novel type of water-cooled reactor to satisfy the Generation IV goals: fuel cycle sustainability, enhanced reliability and safety, and improved economics. The research objectives over the three-year (1999-2002) program were as follows: First year: Assess various design alternatives and establish main characteristics of a point design; Second year: Perform feasibility and engineering assessment of the selected design solutions; Third year: Complete reactor design and performance evaluation, including cost assessment These objectives were fully attained and actually they served to launch IRIS as a full fledged project for eventual commercial deployment. The program did not terminate in 2002 at the end of the NERI program, and has just entered in its fifth year. This has been made possible by the IRIS project participants which have grown from the original four member, two-countries team to the current twenty members, nine countries consortium. All the consortium members work under their own funding and it is estimated that the value of their in-kind contributions over the life of the project has been of the order of $30M. Currently, approximately 100 people worldwide are involved in the project. A very important constituency of the IRIS project is the academia: 7 universities from four countries are members of the consortium and five more US universities are associated via parallel NERI programs. To date, 97 students have worked or are working on IRIS; 59 IRIS-related graduate theses have been prepared or are in preparation, and 41 of these students have already graduated with M.S. (33) or Ph.D. (8) degrees. This ''final'' report (final only as far as the NERI program is concerned) summarizes the work performed in the first four

  13. Preface: The International Reference Ionosphere (IRI) at equatorial latitudes

    Science.gov (United States)

    Reinisch, Bodo; Bilitza, Dieter

    2017-07-01

    This issue of Advances in Space Research includes papers that report and discuss improvements of the International Reference Ionosphere (IRI). IRI is the international standard for the representation of the plasma in Earth's ionosphere and recognized as such by the Committee on Space Research (COSPAR), the International Union of Radio Science (URSI), the International Telecommunication Union (ITU), and the International Standardization Organization (ISO). As requested, particularly by COSPAR and URSI, IRI is an empirical model relying on most of the available and reliable ground and space observations of the ionosphere. As new data become available and as older data sources are fully exploited the IRI model undergoes improvement cycles to stay as close to the existing data record as possible. The latest episode of this process is documented in the papers included in this issue using data from the worldwide network of ionosondes, from a few of the incoherent scatter radars, from the Alouette and ISIS topside sounders, and from the Global Navigation Satellite Systems (GNSS). The focus of this issue is on the equatorial and low latitude region that is of special importance for ionospheric physics because it includes the largest densities and steep density gradients in the double hump latitudinal structure, the Equatorial Ionization Anomaly (EIA), which is characteristic for this region.

  14. Intraocular lens iris fixation. Clinical and macular OCT outcomes

    Science.gov (United States)

    2012-01-01

    Background To assess the efficacy, clinical outcomes, visual acuity (VA), incidence of adverse effects, and complications of peripheral iris fixation of 3-piece acrylic IOLs in eyes lacking capsular support. Thirteen patients who underwent implantation and peripheral iris fixation of a 3-piece foldable acrylic PC IOL for aphakia in the absence of capsular support were followed after surgery. Clinical outcomes and macular SD-OCT (Cirrus OCT; Carl Zeiss Meditec, Germany) were analyzed. Findings The final CDVA was 20/40 or better in 8 eyes (62%), 20/60 or better in 12 eyes (92%), and one case of 20/80 due to corneal astigmatism and mild persistent edema. No intraoperative complications were reported. There were seven cases of medically controlled ocular hypertension after surgery due to the presence of viscoelastic in the AC. There were no cases of cystoid macular edema, chronic iridocyclitis, IOL subluxation, pigment dispersion, or glaucoma. Macular edema did not develop in any case by means of SD-OCT. Conclusions We think that this technique for iris suture fixation provides safe and effective results. Patients had substantial improvements in UDVA and CDVA. This surgical strategy may be individualized however; age, cornea status, angle structures, iris anatomy, and glaucoma are important considerations in selecting candidates for an appropriate IOL fixation method. PMID:23050659

  15. System and prospect assesment of the small innovative reactor IRIS-50

    International Nuclear Information System (INIS)

    Lumbanraja, Sahala M.; Wibowo

    2002-01-01

    System and prospect of the small innovative reactor IRIS-50 in Indonesia have been studied. IRIS-50 (International Reactor Innovative and Secure) is an advanced light water cooled modular reactor being developed by an international consortium led by Westinghouse. This reactor is specifically developed to match market demands, or to developing country. This reactor is based on simplified operation and maintenance, enhanced and safety, easy to inspect, short construction time, small investment cost, competitive generating cost, and easily suited to the infrastructures. IRIS main characteristic is integral reactor concept, being all the major reactor coolant system components located inside the pressure vessel

  16. [A new clinical entity: ascending solar iris degeneration. Report of 284 cases].

    Science.gov (United States)

    Laktaoui, A; Kriet, M; Mellaoui, M; El Wafi, A; Bouzidi, A; Douhal, A; Bouia, Y

    2013-01-01

    The observation in a certain number of subjects of an atypical iris depigmentation led us to study this phenomenon. Therefore, the authors engaged in a prospective study of 398 subjects (100 cases in the city of Marrakesh, and 298 in the city of Dakhla). The geography, clinical signs and environmental factors were studied. Depigmentation was observed in 55% of the population of Marrakesh and 77% of the population of Dakhla. It is bilateral, symmetric, very progressive, always begins in the inferior one-third of the iris, and always spares the superior iris covered by the eyelid. By the time the depigmentation reaches the middle one-third, the inferior one-third also begins to demonstrate stromal atrophy: (26 cases). Of the 45 subjects with normal iris pigmentation, 31 cases spend more than 8 hours per day in the shade, and 26 cases constantly use some means of solar protection (sunglasses, caps, "Taraza", "Feroual"). Thus, this acquired iris depigmentation of an ascending nature, accompanied by an advanced stage involving primarily inferior iris atrophy, appears to be closely associated with exposure to the sun. Ascending solar iris degeneration, if we may refer to it as such, is a clinical entity never before reported in the literature. Now that we are faced with this new condition, numerous questions arise, to which future research must respond. Are there other factors in addition to sun exposure, which may lead to the depigmentation? Does this condition lead to further ocular pathology (due to the depigmentation and stromal atrophy)? Must solar protection be prescribed systematically for anyone at risk? Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  17. Performance of Solar Proxy Options of IRI-Plas Model for Equinox Seasons

    Science.gov (United States)

    Sezen, Umut; Gulyaeva, Tamara L.; Arikan, Feza

    2018-02-01

    International Reference Ionosphere (IRI) is the most acclaimed climatic model of the ionosphere. Since 2009, the range of the IRI model has been extended to the Global Positioning System (GPS) orbital height of 20,000 km in the plasmasphere. The new model, which is called IRI extended to Plasmasphere (IRI-Plas), can input not only the ionosonde foF2 and hmF2 but also the GPS-total electron content (TEC). IRI-Plas has been provided at www.ionolab.org, where online computation of ionospheric parameters is accomplished through a user-friendly interface. The solar proxies that are available in IRI-Plas can be listed as sunspot number (SSN1), SSN2, F10.7, global electron content (GEC), TEC, IG, Mg II, Lyman-α, and GEC_RZ. In this study, ionosonde foF2 data are compared with IRI-Plas foF2 values with the Consultative Committee International Radio (CCIR) and International Union of Radio Science (URSI) model choices for each solar proxy, with or without the GPS-TEC input for the equinox months of October 2011 and March 2015. It has been observed that the best fitting model choices in Root Mean Square (RMS) and Normalized RMS (NRMS) sense are the Jet Propulsion Laboratory global ionospheric maps-TEC input with Lyman-α solar proxy option for both months. The input of TEC definitely lowers the difference between the model and ionosonde foF2 values. The IG and Mg II solar proxies produce similar model foF2 values, and they usually are the second and third best fits to the ionosonde foF2 for the midlatitude ionosphere. In high-latitude regions, Jet Propulsion Laboratory global ionospheric map-TEC inputs to IRI-Plas with Lyman-α, GEC_RZ, and TEC solar proxies are the best choices. In equatorial region, the best fitting solar proxies are IG, Lyman-α, and Mg II.

  18. Pengaruh Customer Service Quality, Customer Perceived Value, Customer Satisfaction, Customer Trust Dan Switching Barriers Terhadap Customer Retention.

    OpenAIRE

    Hardjanti, Adiati; Amalia, Dinna

    2014-01-01

    Penelitian ini bertujuan untuk mengetahui pengaruh customer service quality, customer perceived value, customer satisfaction, customer trust dan switching barriers terhadap customer retention. Rancangan penelitian yang digunakan dalam penelitian ini adalah pengujian hipotesis (testing hypotesis). Pengambilan sampel dalam penelitian ini menggunakan teknik purposive sampling dan keseluruhan hipotesis diuji dengan metode structural equation modeling yang menggunakan Amos 7.0. Data dalam peneliti...

  19. Lantionpohjan toimintahäiriöt : Fysioterapeuttiset hoitokäytännöt

    OpenAIRE

    Halinen, Erika; Pulkkinen, Sari

    2011-01-01

    Lantionpohjan toimintahäiriöt ovat merkittävä naisten elämänlaatua heikentävä vaiva. Lantionpohjan toimintahäiriöitä ovat virtsaamiseen, ulostamiseen ja seksuaalitoimintoihin liittyvät häiriöt sekä laskeumat ja lantionpohjan alueen kiputilat. Suurimmat riskitekijät toimintahäiriöiden synnylle ovat raskauksien, synnytysten ja ikääntymisen mukanaan tuomat lantionpohjan lihas-, sidekudos- ja hermovauriot tai -muutokset. Lantionpohjan eri rakenteet ja toiminnat ovat läheisessä yhteydessä toisiins...

  20. IRIS Bimonthly Public Meeting (Apr 2014)

    Science.gov (United States)

    EPA hosted a public meeting/webinar to provide an opportunity for the public to give input and participate in an open discussion regarding several IRIS chemical assessments for Diethyl Phthalate (DEP) and Hexabromocyclododecane (HBCD).

  1. [Iris hooks and modified capsular tension ring for subluxation lens in patients with Marfan's syndrome].

    Science.gov (United States)

    Wu, Wen-Jie; Zheng, Dan-ying; Zheng, Ying-feng; Cai, Xiao-yu

    2007-02-01

    To evaluate clinical efficiency and safety of the iris hooks and modified capsular tension ring (MCTR) for the treatment of subluxation lens in patients with Marfan's syndrome. This study comprised 5 patients (7 eyes) with Marfan's syndrome and subluxation lens. After 3.2 mm clear cornea incision and continuous curvilinear capsulorhexis (CCC), 2 - 4 disposable nylon iris hooks were inserted through the stab incisions and placed in the capsulorhexis to support the capsule and enlarged the CCC. Following irrigation/aspiration, a MCTR with suture in its eyelet was placed in the capsule bag. After tightening and tying the suture of MCTR, the capsular bag was centered and fixed. A foldable AcrySof one-piece intraocular lens (IOL) was then placed in the capsule bag. Twelve months after the operation, the best corrected visual acuity was >/= 0.8 in six eyes and 0.7 in one eye. The scheimpflug images obtained from the Pentacam demonstrated that the IOL were well centered. UBM showed that all the MCTR and the haptics of the IOL were in the capsule bag, the eyelet of the MCTR was rested stably between the capsulorhexis margin and the iris. The retroillumination photograph indicated that only one eye had obvious posterior capsular opacification. No intraoperative and postoperative complications such as prolapse of vitreous and retina detachment was occurred. The iris hooks can provide excellent intraoperative capsule-lens stability and facilitate the manipulation during operation. MCTR allows additional suture fixation to the eye wall without damaging the capsular bag and maintains the long-term stability of the intraocular lens. Furthermore, MCTR is helpful for avoiding dislocation of the IOL due to progressive weakening of the zonular fibers in some patients and provides long-term safety.

  2. IRI STORM validation over Europe

    Science.gov (United States)

    Haralambous, Haris; Vryonides, Photos; Demetrescu, Crişan; Dobrică, Venera; Maris, Georgeta; Ionescu, Diana

    2014-05-01

    The International Reference Ionosphere (IRI) model includes an empirical Storm-Time Ionospheric Correction Model (STORM) extension to account for storm-time changes of the F layer peak electron density (NmF2) during increased geomagnetic activity. This model extension is driven by past history values of the geomagnetic index ap (The magnetic index applied is the integral of ap over the previous 33 hours with a weighting function deduced from physically based modeling) and it adjusts the quiet-time F layer peak electron density (NmF2) to account for storm-time changes in the ionosphere. In this investigation manually scaled hourly values of NmF2 measured during the main and recovery phases of selected storms for the maximum solar activity period of the current solar cycle are compared with the predicted IRI-2012 NmF2 over European ionospheric stations using the STORM model option. Based on the comparison a subsequent performance evaluation of the STORM option during this period is quantified.

  3. Investigation on equatorial ionospheric profiles and IRI model

    International Nuclear Information System (INIS)

    Adeniyi, J.O.

    1996-01-01

    Ionospheric profiles below the F2 peak ionisation density are compared with those of the International Reference Ionosphere (IRI). The data used are those of Ibadan (Lat. 7.4 deg N, Long. 3.9 E). The IRI model gives a much thinner bottomside F region ionisation density than what is observed experimentally, in winter; both at high and low solar activity. Similar departures are observed in the summer of both solar epoch but on a reduced scale. The closet agreement occurs during the March equinox of high solar activity. (author). 3 refs, 4 figs

  4. [Iris abscess after bacterial endocarditis in a patient with leukaemia. Differential diagnosis].

    Science.gov (United States)

    Manrique Lipa, R; González Sánchez, E; Asencio Duran, M; Gonzalez-Peramato, P; Fonseca Santodomingo, A

    2014-04-01

    To report a case of iris abscess due to bacterial endocarditis. A 46-year-old male under diagnosis of promielocitic leukemia and endocarditis presented with decreased vision in left eye (OS). Ophthalmic exploration revealed iris abscess and hypopyon with fibrinous exudate in iris of the left eye and tyndall +1 in right eye (OD). Blood culture and anterior chamber paracentesis was positive for methicillin-sensitive Staphylococcus aureus and negative for blastic cells in citology. Treatment with systemic antibiotic was initiated with total resolution of inflammation. Iris abscess is an unusual septic focus in bacterial endocarditis. It is crucial to rule out an extramedullary metastasis in a patient with leukemia due to the general prognosis. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  5. Processing of interlaced images in 4–10 MeV dual energy customs system for material recognition

    Directory of Open Access Journals (Sweden)

    S. Ogorodnikov

    2002-10-01

    Full Text Available The aim of this article is to demonstrate the practical value of radioscopic differentiation of materials in the 1–10 MeV energy range to the work of customs services. The proposed method for achieving singling out and identifying four basic groups of materials according to an atomic number is complex. Atomic numbers are identified using high- and low-energy profiles obtained through the irradiation of materials on an alternate pulse-by-pulse basis. This is done using a bremsstrahlung beam with 8   MeV/4   MeV dual boundary energies and by using scintillating crystals coupled with silicon photodiodes as detecting elements. An image segmentation technique is then used to discern the distribution of an atomic number on any given image. The color visualization of integral absorption and a material’s atomic composition is carried out according to the intensity hue saturation (IHS colorization scheme. The experiments were carried out on a full-scale prototype of an 8 MeV customs inspection system developed by the Efremov Research Institute.

  6. Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing

    OpenAIRE

    Wang, Yu-Tzu; Yu, Jian-Hong; Lo, Lun-Jou; Hsu, Pin-Hsin; Lin, CHun-Li

    2017-01-01

    This study integrates cone-beam computed tomography (CBCT)/laser scan image superposition, computer-aided design (CAD), and 3D printing (3DP) to develop a technology for producing customized dental (orthodontic) miniscrew surgical templates using polymer material. Maxillary bone solid models with the bone and teeth reconstructed using CBCT images and teeth and mucosa outer profile acquired using laser scanning were superimposed to allow miniscrew visual insertion planning and permit surgical ...

  7. Design and implementation of an algorithm for creating templates for the purpose of iris biometric authentication through the analysis of textures implemented on a FPGA

    International Nuclear Information System (INIS)

    Giacometto, F J; Vilardy, J M; Torres, C O; Mattos, L

    2011-01-01

    Currently addressing problems related to security in access control, as a consequence, have been developed applications that work under unique characteristics in individuals, such as biometric features. In the world becomes important working with biometric images such as the liveliness of the iris which are for both the pattern of retinal images as your blood vessels. This paper presents an implementation of an algorithm for creating templates for biometric authentication with ocular features for FPGA, in which the object of study is that the texture pattern of iris is unique to each individual. The authentication will be based in processes such as edge extraction methods, segmentation principle of John Daugman and Libor Masek's, and standardization to obtain necessary templates for the search of matches in a database and then get the expected results of authentication.

  8. IRIS Assessment Plan for Ammonia and Ammonium Salts Noncancer Oral (Scoping and Problem Formulation Materials)

    Science.gov (United States)

    In April 2018, EPA released the draft IRIS Assessment Plan for Ammonia and Ammonium Salts Noncancer Oral. An IRIS Assessment Plan (IAP) communicates to the public the plan for assessing each individual chemical and includes summary information on the IRIS Program’s sco...

  9. Enhancing the early differential diagnosis of plateau iris and pupillary block using a-scan ultrasonography.

    Directory of Open Access Journals (Sweden)

    Yu-Yen Chen

    Full Text Available To distinguish the frequently misdiagnosed plateau iris eyes from pupillary block group and normal group, we compared the ocular biometrical parameters of them by A-scan ultrasongraphy.In total, we retrospectively reviewed general characteristics and ocular findings including ocular biometric measurements of 71 normal, 39 plateau iris, and 83 pupillary block eyes.The normal controls, plateau iris group and pupillary block group were significantly different in age, but not in gender. The anterior chamber depth tended to decrease and the lens thickness tended to increase from normal to plateau iris to pupillary block eyes. Compared to those of plateau iris group, the pupillary block group had significantly shallower anterior chamber depth (2.90mm vs. 2.33mm; p<0.001, thicker lens (4.77mm vs. 5.11mm; p<0.001, shorter axial length (23.16mm vs. 22.63mm; p<0.001, smaller relative lens position (2.28 vs. 2.16; p<0.001 and larger lens/axial length factor (2.06 vs. 2.26; p<0.001. However, when comparing plateau iris and normal eyes, only axial length and lens/axial length factor were significantly different (23.16 vs. 23.54; p<0.05 and 2.06 vs. 1.96; p<0.05.Measured by A-scan ultrasonography, the ocular biometrics of plateau iris were significantly different from those of pupillary block eyes. However, our A-scan ultrasongraphy generally found no significant biometric differences between plateau iris and normal eyes. These findings suggest that while A-scan ultrasonography might be used as a practical tool for differentiating plateau iris and papillary block eyes, a more meticulous gonioscopy and other assessments may be necessary to distinguish plateau iris from normal eyes.

  10. The Effect of Innovation Factors to Customer Loyalty by Structural Equation Model

    OpenAIRE

    M. Dachyar; Fatkhurrohman

    2011-01-01

    Innovation is being view from four areas of innovation, product, service, technology, and marketing. Whereas customer loyalty is composed of customer expectation, perceived quality, perceived value, corporate image, customer satisfaction, customer trust/confidence, customer commitment, customer complaint, and customer loyalty. This study aimed to investigate the influence of innovation factors to customer loyalty to GSM in the telecom companies where use of products and s...

  11. Comparison of GPS-derived TEC with IRI-2012 and IRI-2007 TEC predictions at Surat, a location around the EIA crest in the Indian sector, during the ascending phase of solar cycle 24

    Science.gov (United States)

    Patel, N. C.; Karia, S. P.; Pathak, K. N.

    2017-07-01

    This paper presents a comparison of GPS-derived TEC with IRI-2012 and IRI-2007 TEC Predictions at Surat (21.16°N Geographic latitude, 72.78°E Geographic longitude, 12.90°N Geomagnetic latitude) a location around the Equatorial Ionisation Anomaly (EIA) crest in the Indian sector, during the Ascending Phase of Solar Cycle 24, for a period of three years (January 2010-December 2012). In this comparison, plasmaspheric electron content (PEC) contribution to the GPS-TEC has been removed. It is observed that percentage PEC contribution to the GPS-TEC varies from about ∼15% (at the noon local time) to about ∼30% (at the morning local time). From the monthly comparison of GPS-TEC with IRI-TEC, it is observed that, TEC predicted by both the models overestimates in June-2012 and underestimates TEC in November-2011, December-2011 and March-2011. For all other months IRI estimates the TEC well. From the seasonal comparison, it is observed that the peak time appears ∼1-h later than the actual peak time in Winter 2010, Summer 2011, and Equinox 2010 and 2012 (the result suggest that it may be due to discrepancies/disagreement of both the versions of the IRI model in estimating the peak density as well as the thickness and shape parameters of the electron density profiles). For the Summer season, the IRI-TEC estimates the TEC well for all the years. Further, the seasonal variation of the GPS-TEC for all the three years matches well with IRI-2012 model compared to IRI-2007 model. Also, the mean annual TEC is predicted well by both the versions of the IRI model.

  12. Contralateral comparison of wavefront-guided LASIK surgery with iris recognition versus without iris recognition using the MEL80 Excimer laser system.

    Science.gov (United States)

    Wu, Fang; Yang, Yabo; Dougherty, Paul J

    2009-05-01

    To compare outcomes in wavefront-guided LASIK performed with iris recognition software versus without iris recognition software in different eyes of the same patient. A randomised, prospective study of 104 myopic eyes of 52 patients undergoing LASIK surgery with the MEL80 excimer laser system was performed. Iris recognition software was used in one eye of each patient (study group) and not used in the other eye (control group). Higher order aberrations (HOAs), contrast sensitivity, uncorrected vision (UCV), visual acuity (VA) and corneal topography were measured and recorded pre-operatively and at one month and three months post-operatively for each eye. The mean post-operative sphere and cylinder between groups was similar, however the post-operative angles of error (AE) by refraction were significantly smaller in the study group compared to the control group both in arithmetic and absolute means (p = 0.03, p = 0.01). The mean logMAR UCV was significantly better in the study group than in the control group at one month (p = 0.01). The mean logMAR VA was significantly better in the study group than in control group at both one and three months (p = 0.01, p = 0.03). In addition, mean trefoil, total third-order aberration, total fourth-order aberration and the total scotopic root-mean-square (RMS) HOAs were significantly less in the study group than those in the control group at the third (p = 0.01, p = 0.05, p = 0.04, p = 0.02). By three months, the contrast sensitivity had recovered in both groups but the study group performed better at 2.6, 4.2 and 6.6 cpd (cycles per degree) than the control group (p = 0.01, p iris recognition results in better VA, lower mean higher-order aberrations, lower refractive post-operative angles of error and better contrast sensitivity at three months post-operatively than LASIK performed without iris recognition.

  13. A new approach for the analysis of facial growth and age estimation: Iris ratio

    Science.gov (United States)

    Machado, Carlos Eduardo Palhares; Flores, Marta Regina Pinheiro; Lima, Laíse Nascimento Correia; Tinoco, Rachel Lima Ribeiro; Bezerra, Ana Cristina Barreto; Evison, Martin Paul; Guimarães, Marco Aurélio

    2017-01-01

    The study of facial growth is explored in many fields of science, including anatomy, genetics, and forensics. In the field of forensics, it acts as a valuable tool for combating child pornography. The present research proposes a new method, based on relative measurements and fixed references of the human face—specifically considering measurements of the diameter of the iris (iris ratio)—for the analysis of facial growth in association with age in children and sub-adults. The experimental sample consisted of digital photographs of 1000 Brazilian subjects, aged between 6 and 22 years, distributed equally by sex and divided into five specific age groups (6, 10, 14, 18, and 22 year olds ± one month). The software package SAFF-2D® (Forensic Facial Analysis System, Brazilian Federal Police, Brazil) was used for positioning 11 landmarks on the images. Ten measurements were calculated and used as fixed references to evaluate the growth of the other measurements for each age group, as well the accumulated growth (6–22 years old). The Intraclass Correlation Coefficient (ICC) was applied for the evaluation of intra-examiner and inter-examiner reliability within a specific set of images. Pearson’s Correlation Coefficient was used to assess the association between each measurement taken and the respective age groups. ANOVA and Post-hoc Tukey tests were used to search for statistical differences between the age groups. The outcomes indicated that facial structures grow with different timing in children and adolescents. Moreover, the growth allometry expressed in this study may be used to understand what structures have more or less proportional variation in function for the age ranges studied. The diameter of the iris was found to be the most stable measurement compared to the others and represented the best cephalometric measurement as a fixed reference for facial growth ratios (or indices). The method described shows promising potential for forensic applications

  14. A new approach for the analysis of facial growth and age estimation: Iris ratio.

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Palhares Machado

    Full Text Available The study of facial growth is explored in many fields of science, including anatomy, genetics, and forensics. In the field of forensics, it acts as a valuable tool for combating child pornography. The present research proposes a new method, based on relative measurements and fixed references of the human face-specifically considering measurements of the diameter of the iris (iris ratio-for the analysis of facial growth in association with age in children and sub-adults. The experimental sample consisted of digital photographs of 1000 Brazilian subjects, aged between 6 and 22 years, distributed equally by sex and divided into five specific age groups (6, 10, 14, 18, and 22 year olds ± one month. The software package SAFF-2D® (Forensic Facial Analysis System, Brazilian Federal Police, Brazil was used for positioning 11 landmarks on the images. Ten measurements were calculated and used as fixed references to evaluate the growth of the other measurements for each age group, as well the accumulated growth (6-22 years old. The Intraclass Correlation Coefficient (ICC was applied for the evaluation of intra-examiner and inter-examiner reliability within a specific set of images. Pearson's Correlation Coefficient was used to assess the association between each measurement taken and the respective age groups. ANOVA and Post-hoc Tukey tests were used to search for statistical differences between the age groups. The outcomes indicated that facial structures grow with different timing in children and adolescents. Moreover, the growth allometry expressed in this study may be used to understand what structures have more or less proportional variation in function for the age ranges studied. The diameter of the iris was found to be the most stable measurement compared to the others and represented the best cephalometric measurement as a fixed reference for facial growth ratios (or indices. The method described shows promising potential for forensic

  15. Maintenance Cycle Extension in the IRIS Advanced Light Water Reactor Plant Design

    International Nuclear Information System (INIS)

    Galvin, Mark R.; Todreas, Neil E.; Conway, Larry E.

    2003-01-01

    New nuclear power generation in the United States will be realized only if the economic performance can be made competitive with other methods of electrical power generation. The economic performance of a nuclear power plant can be significantly improved by increasing the time spent on-line generating electricity relative to the time spent off-line conducting maintenance and refueling. Maintenance includes planned actions (surveillances) and unplanned actions (corrective maintenance) to respond to component degradation or failure. A methodology is described that can be used to resolve, in the design phase, maintenance-related operating cycle length barriers. A primary goal was to demonstrate the applicability and utility of the methodology in the context of the International Reactor, Innovative and Secure (IRIS) design. IRIS is an advanced light water nuclear power plant that is being designed to maximize this on-line generating time by increasing the operating cycle length. This is consequently a maintenance strategy paper using the IRIS plant as the example.Potential IRIS operating cycle length maintenance-related barriers, determined by modification of an earlier operating pressurized water reactor (PWR) plant cycle length analysis to account for differences between the design of IRIS and this operating PWR, are presented. The proposed methodology to resolve these maintenance-related barriers by the design process is described. The results of applying the methodology to two potential IRIS cycle length barriers, relief valve testing and emergency heat removal system testing, are presented

  16. Alpha antagonists and intraoperative floppy iris syndrome: A spectrum

    Directory of Open Access Journals (Sweden)

    Sharif A Issa

    2008-07-01

    Full Text Available Sharif A Issa, Omar H Hadid, Oliver Baylis, Margaret DayanDepartment of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne, UKBackground: To determine occurrence of features of intraoperative floppy iris syndrome (IFIS during cataract surgery in patients taking systemic alpha-antagonists (AA.Methods: We prospectively studied patients on AA and who underwent phacoemulsification. The following were recorded: pupil diameter preoperatively, iris flaccidity, iris prolapse and peroperative miosis.Results: We studied 40 eyes of 31 subjects. Mean age was 78 years. Overall, 14 eyes (13 patients showed signs of IFIS: 9/13 (69% eyes of patients on tamsulosin, 1/18 (6% eyes in the doxazosin group, 2/2 prazosin patients, 1/4 eyes in the indoramin group, and 1/2 eyes in two patients on a combination of doxazosin and tamsulosin. Most cases (92% had only one or two signs of IFIS. Bilateral cataract surgery was undertaken in 9 patients but only one patient (on tamsulosin had features of IFIS in both eyes, while 4 patients (2 on tamsulosin and 2 on other AA showed signs of IFIS in one eye only, and 4 patients did not show IFIS in either eye.Conclusion: Most AA were associated with IFIS, but it tends to present as a spectrum of signs rather than full triad originally described. Tamsulosin was most likely to be associated with IFIS; however, its intake does not necessarily mean that IFIS will occur. For patients on AA, the behavior of the iris intraoperatively in one eye is a poor predictor of the other eye. Surgeons should anticipate the occurrence of IFIS in any patient on AA.Keywords: alpha blocker, alpha antagonist, cataract surgery, intraoperative floppy iris syndrome, tamsulosin.

  17. Clinical observation of Artisan iris-clip intraocular lens implantation at stage Ⅰ

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2014-09-01

    Full Text Available AIM: To observe the clinical efficacy of Artisan iris-clip intraocular lens(IOLimplantation on cataract with a wide range of lens dislocation.METHODS: Twenty-four hospital patients(28 eyesof cataract with lens subluxation by trauma(20 patients, 20 eyesand Marfan's syndrome(4 patients, 8 eyesduring May 2007 to December 2011 were selected. All of them underwent phacoemulsification or an anterior vitrectomy and Artisan iris-clip IOL implantation at stage Ⅰ. Postoperative visual acuity, corneal endothelial cell count, intraocular lens position and postoperative complications were observed. Follow-up time was 6mo.RESULTS:Compared with the preoperative, postoperative best corrected visual acuity improved to varying degrees, visual acuity of 0.1-0.5 was in 20 eyes, 0.5-1.0 in 8 eyes. After followed up 1-6mo, no artificial lens shift, iris inflammation, iris atrophy and corneal decompensation and other complications were observed.CONCLUSION: Cataract surgery with a wide range of lens dislocation is difficult, but as long as surgeons who have a wealth of clinical experience and superb skills, still can carry out phacoemulsification surgery or anterior vitrectomy and Artisan iris-clip IOL implantation and obtain a better outcome.

  18. Are loyal customers profitable? : customer satisfaction, customer loyalty and customer profitability at the individual level

    OpenAIRE

    Helgesen, Øyvind

    2000-01-01

    Customer satisfaction is supposed to be positively related to profitability. This conception may be called “the paradigm of customer satisfaction”. Nevertheless, only a few studies have examined this fundamental relationship. Thus, evidence for this “much talked about relationship” is questioned. In this working paper the focus is on the individual customer with respect to the relationships between customer satisfaction, customer loyalty and customer profitability at the customer level. The f...

  19. The Economics of IRIS

    International Nuclear Information System (INIS)

    Miller, K.; Paramonov, D.

    2002-01-01

    IRIS (International Reactor Innovative and Secure) is a small to medium advanced light water cooled modular reactor being developed by an international consortium led by Westinghouse/BNFL. This reactor design is specifically aimed at utilities looking to install new (or replacement) nuclear capacity to match market demands, or at developing countries for their distributed power needs. To determine the optimal configuration for IRIS, analysis was undertaken to establish Generation Costs ($/MWh) and Internal Rate of Return (IRR %) to the Utility at alternative power ratings. This was then combined with global market projections for electricity demand out to 2030, segmented into key geographical regions. Finally this information is brought together to form insights, conclusions and recommendations regarding the optimal design. The resultant analysis reveals a single module sized at 335 MWe, with a construction period of 3 years and a 60-year plant life. Individual modules can be installed in a staggered fashion (3 equivalent to 1005 MWe) or built in pairs (2 sets of twin units' equivalent to 1340 MWe). Uncertainty in Market Clearing Price for electricity, Annual Operating Costs and Construction Costs primarily influence lifetime Net Present Values (NPV) and hence IRR % for Utilities. Generation Costs in addition are also influenced by Fuel Costs, Plant Output, Plant Availability and Plant Capacity Factor. Therefore for a site based on 3 single modules, located in North America, Generations Costs of 28.5 $/MWh are required to achieve an IRR of 20%, a level which enables IRIS to compete with all other forms of electricity production. Plant size is critical to commercial success. Sustained (lifetime) high factors for Plant Output, Availability and Capacity Factor are required to achieve a competitive advantage. Modularity offers Utilities the option to match their investments with market conditions, adding additional capacity as and when the circumstances are right

  20. Reparative processes of the iris after irradiation with the argon-ion laser

    International Nuclear Information System (INIS)

    Huber, G.K.; Zypen, E. van der; Fankhauser, F.

    1979-01-01

    The reparative processes of the pigmented iris of the rabbit were analysed with ultrastructural methods. Clearing of the damaged area by macrophages is the first step in the reparative processes. Clump cells are macrophages which are observed from the first day of the injury until the ninth week. Repair of the anterior surface of the iris is largely finished after 32 days. The repair of collagenous fibres reaches its maximum activity 32 days after irradiation. The pigment epithelium has only an insignificant regeneration potential. Irradiation of the iris by the argon-ion laser results in an atropic, hyperpigmented scar. The rapid regeneration of a lesion induced by the argon-ion laser in the rabbit iris casts doubt as to whether this method could be applied to the human eye with equal success. (orig.) 891 AJ/orig. 892 MB