WorldWideScience

Sample records for ird-whole body counter

  1. Intercalibration of CDTN and IRD whole body counters

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Alonso, T.C.

    2008-01-01

    Full text: Intercalibration exercises are designed to harmonize analytical techniques and ensure reliability of measurement results performed in a laboratory network. Such strategy helps to improve laboratory performance among participants in future intercomparison exercises, when it is verified the metrological capacity, by determining accuracy, precision and reproducibility of data produced by each laboratory. In Brazil, there are currently four in vivo monitoring systems, located in IRD, in Rio de Janeiro, CDTN, in Belo Horizonte, IPEN, in Sao Paulo and CNAAA, in Angra dos Reis. Such systems, generically referred as whole body counters, aim to detect and quantify radionuclides in organs and tissues for radiological protection purposes and to provide useful information for studies on biokinetic behavior of radionuclides in humans and animals. The objective of this work is to establish a methodology to be applied for intercalibration of whole body counters. The IRD whole body counter is installed in a 15 cm steel shielded room where two NaI(Tl) and four HPGe detectors are calibrated for the determination of radionuclides in the energy range from 10 to 3000 keV. The CDTN whole body counter has one NaI detector set up in a shadow shield configuration, and is able to determine radionuclides emitting photons from 100 to 2000 keV. The intercalibration exercise described in this work was planed for whole body geometry using the scintillation detectors available in both laboratories. It was used a thin glass vial containing 2,6615 g of a solution of four gamma emitters ( 57 Co, 137 Cs, 54 Mn, 65 Zn), supplied by the National Laboratory for Metrology of Ionizing Radiation (LNMRI-IRD). The glass vial was measured in the same geometry in both IRD and CDTN whole body counters, being positioned at 31,5 cm distance from the NaI(Tl) detector of each laboratory. The calibration curves (photo peak channel and Efficiency vs Energy) of each detection system were compared. The

  2. IRD-CNEN whole body counter capabilities for in vivo monitoring of internally deposited radionuclides in human body

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, A.L.A.; Lucena, E.A.; Dantas, B.M., E-mail: adantas@ird.gov.br, E-mail: eder@ird.gov.br, E-mail: bmdantas@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Monitoracao in Vivo

    2015-07-01

    Internal exposure to radionuclides may occur as a result of a variety of practices, such as in nuclear industry, production of radiopharmaceuticals and nuclear medicine, biological research and agriculture; as well as in mining and milling of minerals with associated NORM. The IRD whole-body counter consists of shielded room equipped with an array of four HPGe detectors and two NaI(Tl) with dimensions of 8” x 4” and 3” x 3”. The detection systems are able to detect and quantify a large variety of radionuclides emitting photons in the energy range from 10 to 3000 keV. The minimum detectable activities for most of the radionuclides of interest allow occupational monitoring as well evaluation of accidental intakes. (author)

  3. Sensitivity of the IRD whole-body counter for in vivo measurements in the case of accidental intakes

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, B.M.; Lucena, E.A.; Dantas, A.L.A., E-mail: bmdantas@ird.gov.br, E-mail: eder@ird.gov.br, E-mail: adantas@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil), Laboratorio de Monitoracao In Vivo

    2016-07-01

    Intakes of radionuclides by humans may occur in the fuel cycle, nuclear medicine, biological research and in TENORM industries and in case of accidents involving workers and the general public. In vivo monitoring is recognized as a useful tool for the evaluation of such exposures. The IRD whole-body counter consists of a shielded room equipped with four HPGe and two NaI(Tl) detectors. The system is able to identify and quantify photon emitters in the range from 10 to 3000 keV. The minimum detectable activities for most of the radionuclides of interest allow occupational monitoring as well evaluation of accidental intakes. (author)

  4. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  5. Whole body monitoring - Goiania

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Bertelli Neto, L.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: - Individual from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1). - Occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121,57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was established according to the Cs activity present in the body or to the job to be assigned. In this paper we will present some burden activity curves for Cs 137 as a function of the time elapsed from the first measurement. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity x time curve. (author) [pt

  6. Whole-body monitoring: Goiania case, Brazil

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Dantas, B.M.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: individuals from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1); occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121, 57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was stablished according to the Cs activity present in the body or to the job that will be done. Some body burden activity curves for Cs 137 as a function of the time elapsed from the first measurement, are presented. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity X time curve. (author) [pt

  7. Current capabilities of the IRD-CNEN-RJ whole body counter for in vivo monitoring of internally deposited radionuclides in human body

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Bernando Maranhao; Dantas, Ana Leticia Almeida; Lucena, Eder Augusto, E-mail: bmdantas@ird.gov.br, E-mail: adantas@ird.gov.br, E-mail: eder@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Monitoracao In Vivo. Div. de Dosimetria

    2014-07-01

    Occupational exposure to radioactive materials may occur as a result of a variety of professional human activities, such as in nuclear industry; use of unsealed sources in nuclear medicine, biological research and agriculture; production of radiopharmaceuticals, as well as in mining and milling of minerals associated with naturally occurring radioactive materials. The IRD whole-body counter (UCCI) consists of a shielded room with internal dimensions of 2.5 m x 2.5 m x 2.5 m. The walls are made of steel and have a graded-Z interior lining made of 3 mm of lead, 1.5 mm of cadmium and 0.5 mm of copper. Such thin layers are aimed to reduce environmental sources of natural background radiation that would affect the measurements of radionuclides emitting low energy photons. An array of four HPGe detectors was used to perform low-energy measurements of radionuclides emitting photons in the energy range from 10 to 200 keV in the lungs, liver and bone tissue. Additionally, one NaI(Tl)8” x 4” and one NaI(Tl)3” x 3” scintillation detectors are used for measurements in the energy range from 100 up to 3000 keV. A configuration of detector supports allows setting up flexible counting geometries, i.e., whole body and specific organs such as head, lungs, liver and thyroid of an individual laid on a monitoring chair. The UCCI is able to perform in vivo measurement of a large variety of radionuclides emitting photons in the energy range from 10 to 3000 keV. The minimum detectable activities for most of the radionuclides of interest allow its application for occupational monitoring as well as in the case of accidental incorporations. (author)

  8. Calibration of the LDI/CDTN Whole Body Counter using three physical phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, F.G.; Fonseca, T.C.F. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dep. de Engenharia Nuclear; Mendes, B.M.; Silva, T.A. da; Lacerda, M.A.S.; Pinto, J.R.; Prates, S.; Filho, N.N.A., E-mail: fgpaiva92@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte/MG (Brazil); Dantas, A.L.A.; Dantas, B.M. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology (LDI/CDTN) is responsible for routine monitoring of internal contamination of the Individuals Occupationally Exposed (IOEs) at the Unit for Research and Production of Radiopharmaceuticals (UPPR/CDTN), the Research Reactor TRIGA-IPR-R1/CDTN and other workplaces of the institute where there is a risk of accidental intakes. Additionally, LDI supports the Institute of Radiation Protection and Dosimetry (IRD/CNEN) to attend radiological emergencies. The determination of photon emitting radionuclides in the human body requires the use of calibration techniques in different counting geometries for converting the count rates into activity in organs and tissues. This paper presents and discusses the calibration of the LDI/CDTN Whole Body Counter (WBC) using a standard BOMAB phantom (Bottle Mannequin Absorber) compared to a home-made phantom produced with Polyethylene Terephthalate bottles (PET). Initially, the BOMAB was filled with a cocktail containing {sup 60}Co, {sup 137}Cs and {sup 133}Ba. The phantom was counted at the LDI whole body counter and an Efficiency x Energy curve was obtained. Subsequently the PET-BOMAB was filled with the same standard source and a second curve was determined. The efficiency values in each region of interest as well as the shape of both curves were found to be equivalent. The results validate the use of the PET-BOMAB for the calibration of whole body geometry applied to the measurement of high energy photon emitting radionuclides in the energy region evaluated in this work. (author)

  9. Internal contamination monitoring through measurements in vivo at whole body contamination unity of IRD-CNEN, Rio de Janeiro, Brazil; Monitoracao da contaminacao interna atraves de medicoes in vivo na Unidade de Contador de Corpo Inteiro do IRD-CNEN, Rio de Janeiro, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Ana Leticia A.; Lucena, Eder A.; Dantas, Bernardo M., E-mail: adantas@ird.gov.b, E-mail: eder@ird.gov.b, E-mail: bmdantas@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. de Monitoracao In Vivo. Servico de Monitoracao Individual Interna

    2011-10-26

    The present work approaches the internal contamination monitoring capacity through measurements performed at the Whole-body Counter Unity of the in-vivo monitoring laboratory (LABMIV) of the IRD-CNEN, Rio de Janeiro, Brazil, present thr main parameters related to the monitoring techniques developed, and the the available instrumentation for identification and quantification in vivo of photon emitter radionuclides with energy in the range of 10-3000 keV, incorporated by workers and public individuals

  10. Development of a low-cost whole body counter

    International Nuclear Information System (INIS)

    Smith, M.H.; Gross, G.P.

    1991-01-01

    This paper documents the construction and calibration of a whole-body counter for the Radiation Safety Office of the Mayo Clinic in Rochester, MN. Changes in the federal regulations may require improved documentation of internal dose for radiation workers. A relatively inexpensive and simple chair-type whole-body counter may suit the needs of many organizations for in vivo assessment of gamma emitting radionuclides. A simple calibration phantom and a spreadsheet computer program were developed in conjunction with the counter. The spreadsheet can be used to calculate an estimate of committed effective dose equivalent based on activity in a subject and data from ICRP Publication 30. Using a count time of 10 minutes, the counter's minimum detectable activity ranged from 370 Bq to 1,110 Bq for 60 Co and 57 Co respectively. Other institutions will be able to assemble whole-body counters at low cost, often from surplus components. The spreadsheet is easily adapted to the needs of any institution and uses current methodology to estimate internal dose

  11. Whole body counters: types, performance and uses

    International Nuclear Information System (INIS)

    Jales, R.L.C.

    1983-01-01

    The present monograph deals with Whole Counters, since its definition, evolution, performance, clinical indications and results. Scintillation crystals detection systems were described as well as scintillant solutions, plastic scintillations, and gaseous detectors, including its interplay forms and basal characteristics. Geometric arrangements of standard chair, arc and hammock, arrangements with scintillant solutions and plastic scintillations, as well as special geometric arrangements were equally commented. Clinic and experimental studies were also dealt with Whole Body Counters, giving examples with potassium, iron vitamin B 12 and albumin. (author)

  12. Improvement of measuring techniques with whole-body and partial-body counters

    International Nuclear Information System (INIS)

    Anon

    1998-01-01

    Mathematical simulation methods have been applied for optimizing and standardizing the calibration of whole-body and partial-body counters for any nuclide accumulation in the human body. (orig./CB) [de

  13. Standardization of calibration method of whole-body counter. 1. Calibration by using anthropometric phantoms

    International Nuclear Information System (INIS)

    Ishikawa, Tetsuo; Matsumoto, Masaki; Uchiyama, Masafumi; Kobayashi, Sadayoshi; Mizushita, Seiichi.

    1995-01-01

    To standardize the calibration methods of whole-body counters, three anthropometric phantoms were manufactured based on dozens of Japanese average value of body size data. Using these phantoms, the calibrations of some whole-body counters were carried out and the comparison of counting efficiency between anthropometric phantoms and block phantoms, which used to be used for the calibration of whole-body counters generally, was implemented. Five whole-body counters, one scanning system, two stationary systems and two chair systems, were used for this study. The following results were derived: As an example, in NIRS scanning system, the counting efficiency of anthropometric phantom of 162cm height was 12.7% greater than that of block phantom of the same height. This means 137 Cs body burdens in adult men used to be estimated with the excess of about 10%. Body burdens tended to be estimated excessively in adult because the difference of counting efficiency between anthropometric phantom and block phantom increases with increase of height. To standardize body burden data measured with various whole-body counters, the calibration of each whole-body counter should be conducted using anthropometric phantoms and phantoms which used to be used for the calibration of that whole-body counter. (author)

  14. The whole-body counter of the radiation centre Giessen

    International Nuclear Information System (INIS)

    Strobelt, W.

    1976-01-01

    The layout of the whole-body counter at the institute for biophysics of the Giessen radiation centre is decribed. With suitable collimators, the whole-body counter may be used to determine the radioactivity in human and animal organs. The shielding and the measuring and waiting rooms for the patients are described with regard to their technical details. The whole-body counting system enables the radioactivity and the retention of various radioisotopes (e.g. 58 Co-vitamin B 12 , 40 K, 54 Mn, 137 Co, 131 J, 22 Na) to be measured. The estimation of the radiation exposure due to different types of examinations in nuclear medicine, in terms of the critical organs for each type of examination, is very accurate with this counting device. (GSE) [de

  15. Calibration of Single High Purity Germanium Detector for Whole Body Counter

    International Nuclear Information System (INIS)

    Taha, T.M.; Morsi, T.M.

    2009-01-01

    A new Accuscan II single germanium detector for whole body counter was installed in NRC (Egypt). The current paper concerned on calibration of single high purity germanium detector for whole body counter. Physical parameters affecting on performance of whole body counter such as linearity, minimum detectable activity and source detector distance, SDD were investigated. Counting efficiencies for the detector have been investigated in rear wall, fixed diagnostic position in air. Counting efficiencies for organ compartments such as thyroid, lung, upper and lower gastrointestinal tract have been investigated using transfer phantom in fixed diagnostic and screening positions respectively. The organ compartment efficiencies in screening geometry were higher than that value of diagnostic geometry by a factor of three. The committed dose equivalents of I-131 in thyroid were ranged from 0.073 ± 0.004 to 1.73±0.09 mSv and in lung was 0.02±0.001 mSv

  16. Whole-body counting installation for assessment of internal contamination in workers

    International Nuclear Information System (INIS)

    Oliveira, C.A.N.; Cunha, P.G.; Lipsztein, J.L.; Bertelli, L.N.; Fonseca, A.M.G.; Ramalho, A.T.

    1985-01-01

    A whole-body counting installation for assessment of internal contamination in workers has recently been added to the Bioassay Division of the Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (IRD/CNEN). For the last two years the laboratory has been monitoring personnel involved in uranium mining and milling activities, monazite industry workers and nuclear medicine staff dealing with iodine-131 and technetium-99. Uptakes of radionuclides by the different organs and also dose equivalents are evaluated through the use of mathematical models. The IRD whole-body counter unit was specially designed to detect a variety of internally deposited radionuclides which emit photons in the energy range of 15 keV to 3 MeV. It consists of a monitoring room (2.5x2.5x2.5 m internal dimension), with 0.15 m thick steel walls, internally lined with 0.3 cm lead, 0.15 cm cadmium and 0.05 cm thick copper sheets. The facility is equipped with three different size NaI(T1) detectors and three 12.7 cm diameter phoswich detectors. (author)

  17. National survey of human body radioactivity measured by a mobile whole-body counter and installed whole-body counters

    International Nuclear Information System (INIS)

    Boddy, K.; Fenwick, J.D.; McKenzie, A.L.

    1989-05-01

    Body radioactivity in the general public has been measured in 2339 volunteers throughout the U.K. A mobile whole-body monitor visited collaborating Medical Physics Departments and data were also contributed by Medical Physics Departments possessing installed counters. Levels of body radiocaesium ranged from below detection level to 4149 Bq. Radiocaesium levels were normalised by dividing by the content of natural body potassium-40. In all cases, the dose rate to the body from radiocaesium was less than that from potassium-40. Radiocaesium levels were 2-3 times higher in N.W. England, Scotland and N. Wales than the rest of the country, but this factor is much less than the variation in deposition of Chernobyl radiocaesium. This discrepancy may be accounted for by the nationwide distribution of foodstuffs. At all sites where volunteers were monitored, the ratio of caesium-137/caesium-134 was consistent with a radiocaesium intake attributable primarily to fallout from the Chernobyl fire. (author)

  18. Oak Ridge National Laboratory whole-body counter: internal operating procedure manual

    International Nuclear Information System (INIS)

    Berger, C.D.; Lane, B.H.

    1982-08-01

    The general purpose of the ORNL Whole Body Counter is to provide a rapid estimation of the type and quantity of radionuclide deposited in the human body. This report contains a review of the equipment in use at the facility and the procedure for its operation, the standard procedure for performing a routine whole body count, and a discussion of interpretation of results

  19. Application of Whole Body Counter to Neutron Dose Assessment in Criticality Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, O.; Tsujimura, N.; Takasaki, K.; Momose, T.; Maruo, Y. [Japan Nuclear Cycle Development Institute, Tokai (Japan)

    2001-09-15

    Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of {sup 24}Na in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of {sup 24}Na is approximately 50Bq for 10minute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 [(Bq{sup 24}Na/g{sup 23}Na)/mGy].

  20. Development of personnel dose control system and whole body counter system

    International Nuclear Information System (INIS)

    Ooki, Yasushi; Harato, Kenji

    2005-01-01

    We delivered Personnel Dose Control System to Higashidohri nuclear plant of Tohoku Electric Power Company, in November 2004. In this system development, we automated the registration of radiation worker with close link between this system and Whole Body Counter System. In addition, this system enables the user to reduce workload for accumulation and notification of personal exposure data, because we adopted the system to extract the data effectively operating the terminal PC which the associate company gets ready in their office. We also delivered Whole body Counter System in December 2004, which was developed to measure internal exposure without feeling of oppression in chair-style device for the first time in Japan. This system enables non-operator system for measurement allowing workers to operate by themselves. (author)

  1. Possibility of semiconductor counters application for internal contamination measurement of whole human body

    International Nuclear Information System (INIS)

    Cunic, O.; Orlic, M.; Bek-Uzarov, Dj.; Pavlovic, S.; Pavlovic, R.

    1997-01-01

    The possibility of high resolution semiconductor counters application in 'Vinca' Whole Body Counter for direct beta-gamma internal contamination measurement are discussed, assuming the following relevant characteristics: efficiency, resolution and counter price. A comparison with appropriate characteristics of NaI(Tl) crystal used in 'Vinca' WBC is treated. It is evident that the scintillation counters have the higher detection efficiency, but HPGe counters having much better resolution and recently lowest prices are also acceptable to join the existing NaI(Tl) counters with the HPGe counters in the same time, allow better spectral analyses of the human body activity and additionally more precise estimation of the equivalent doses rate which is generally a essential problem in WBC measurements. (author)

  2. Measurement of body potassium with a whole-body counter: relationship between lean body mass and resting energy expenditure

    International Nuclear Information System (INIS)

    Jensen, M.D.; Braun, J.S.; Vetter, R.J.; Marsh, H.M.

    1988-01-01

    We conducted studies to determine whether the Mayo whole-body counter could be used to measure body potassium, and thus lean body mass (LBM), and whether moderate obesity alters resting energy expenditure when corrected for LBM. Twenty-four nonobese and 18 moderately obese adults underwent body potassium (40K) counting, as well as tritiated water space measurement and indirect calorimetry. LBM values predicted from 40K counting and tritiated water space measurements were highly correlated (P = 0.001; r = 0.88). Resting energy expenditure was closely related to LBM (P less than 0.0001; r = 0.78): kcal/day = 622 kcal + (LBM.20.0 kcal/kg LBM). In this relationship, the obese subjects did not differ from nonobese subjects. In summary, the Mayo whole-body counter can accurately measure LBM, and moderate obesity has no detectable effect on corrected resting energy expenditure

  3. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L.

    2009-01-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  4. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: cmo@cdtn.br

    2009-07-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  5. Calibration of the whole body counter at PSI

    International Nuclear Information System (INIS)

    Mayer, Sabine; Boschung, Markus; Fiechtner, Annette; Habegger, Ruedi; Meier, Kilian; Wernli, Christian

    2008-01-01

    At the Paul Scherrer Institut (PSI), measurements with the whole body counter are routinely carried out for occupationally exposed persons and occasionally for individuals of the population suspected of radioactive intake. In total about 400 measurements are performed per year. The whole body counter is based on a p-type high purity germanium (HPGe) coaxial detector mounted above a canvas chair in a shielded small room. The detector is used to detect the presence of radionuclides that emit photons with energies between 50 keV and 2 MeV. The room itself is made of iron from old railway rails to reduce the natural background radiation to 24 n Sv/h. The present paper describes the calibration of the system with the IGOR phantom. Different body sizes are realized by different standardized configurations of polyethylene bricks, in which small tubes of calibration sources can be introduced. The efficiency of the detector was determined for four phantom geometries (P1, P2, P4 and P6 simulating human bodies in sitting position of 12 kg, 24 kg, 70 kg and 110 kg, respectively. The measurements were performed serially using five different radionuclide sources ( 40 K, 60 Co, 133 Ba, 137 Cs, 152 Eu) within the phantom bricks. Based on results of the experiment, an efficiency curve for each configuration and the detection limits for relevant radionuclides were determined. For routine measurements, the efficiency curve obtained with the phantom geometry P4 was chosen. The detection limits range from 40 Bq to 1000 Bq for selected radionuclides applying a measurement time of 7 min. The proper calibration of the system, on one hand, is essential for the routine measurements at PSI. On the other hand, it serves as a benchmark for the already initiated characterisation of the system with Monte Carlo simulations. (author)

  6. The establishment of bed type germanium-based whole body counters

    International Nuclear Information System (INIS)

    Chen, M.C.; Sun, C.L.; Yeh, W.W.

    1996-01-01

    A coaxial germanium detector was installed in a shadow-shield counter for the in-vivo measurement of γ emitters in the body. It is divided into two subparts, automatic liquid nitrogen transfer system and the Ge-based counting system. The automatic liquid nitrogen transfer system and a complete gamma spectroscopy software package were manufactured by EG and G ORTEC company. Some experiments were finished to get the optimum three setting parameters for how to operate the auto liquid nitrogen transfer system in good conditions. The filling interval should be setting at eight hours, the filling time should be setting at ten minutes, and the pressure of dewar should operate in a range from 14 to 26 PSI. The RMC-II phantom that is designed by Canberra company is used as standard man for all kinds of calibrations. The detector has resolutions that are less than 2.5 keV with an average of 1.87 keV for the 60 Co 1.33-MeV γ-ray peak. The efficiency value of thyroid geometry for four different organs is highest in the phantom. The resolution of the Germanium detector for measuring radioactivity in the body that is better than the sodium iodide detector is used to measure the internal depositions of radionuclide mixtures. So, the advantage of the germanium counter can just compensate the disadvantage of the NaI(TI) detector. The qualitative and quantitative analysis for whole body counting can keep in the best conditions if both whole body counters are operated at the same time for routine measurement purpose in the laboratory

  7. Estimation of throium deposited in thorotrast patients by whole body counter

    International Nuclear Information System (INIS)

    Tatsumi-Miyajima, Junko; Okajima, Shunzo; Takao, Hideaki; Norimura, Toshiyuki.

    1986-01-01

    Thorotrast, a colloidal solution of thorium dioxide was injected to wounded soldiers, for angiography from 1930 to 1945. The patients who received Thorotrast are interesting objects for finding a biological effect due to the internal irradiation by 232 Th. To determine a distribution and body burden of 232 Th, forty-one Thorotrast patients were measured their gamma-rays with a pair of NaI(T1) scintillation detectors coaxially positioned above and below the coach in the whole body counter of Nagasaki University. The comparison between the usual method using constant values and the method using individual values depend on the organ positions determined with CT (Computed Tomography) scanner for patients was performed to estimate the errors due to the individual differences in the detection efficiency of 232 Th. From the results, the estimates by the whole body counter of the amounts of 232 Th deposits in abdominal region were obtained within the uncertainties of 16 %. And the absorbed dose in the liver and the spleen was also estimated from the amounts of 232 Th. (author)

  8. An investigation into the potassium body burden in humans with the help of a whole-body counter

    International Nuclear Information System (INIS)

    Selzer, A.

    1981-01-01

    The purpose of this study was to examine the available information concerning the potassium body burden of a large number of adults and to find a correlation with other easily measurable body parameters such as mass, height and age so that a normal expected body potassium may be predicted for patients with potassium abnormalities who are also referred to the whole-body counter. The calibration of the whole-body counter to make provision for the differences in geometry and absorption in various body sizes was carried out by injecting a number of people with a small dose of potassium-42 and calculating a correction factor for the potassium standard which is in use daily. All measurements of body potassium were corrected with the calculated correction factor. Fatty tissue in the body contains very little potassium in comparison with muscle tissue and a better correction should therefore be obtained between body potassium and lean body mass. Although it is not possible to predict the smaller potassium abnormalities even when lean body mass is used, the derived regression equation in which lean body mass and age are used, may be viewed as a good first approach in the advance estimation of body potassium

  9. Monitoring of the internal contamination through the in vivo measurements at the whole-body counting unity of the IRD-CNEN, Rio de Janeiro, Brazil; Monitoracao da contaminacao interna atraves de medicoes in vivo na unidade de contador de corpo inteiro do IRD-CNEN, Rio de Janeiro, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Ana Leticia A.; Lucena, Eder A.; Dantas, Bernardo M., E-mail: adantas@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The present work approaches the capacity of Whole Body Counting Unity (WBCU) of IRD, Rio de Janeiro, Brazil, presenting the main parameters relative to the techniques of monitoring developed, and the available instrumentation for identification and quantification in vivo of radionuclides photon emitters with energies in the range of 10-3000 keV, incorporated by workers and public individuals

  10. High-resolution gamma spectroscopy with whole-body and partial-body counters. Experience, recommendations. Report

    International Nuclear Information System (INIS)

    Sahre, P.

    1997-12-01

    The application of high-resolution gamma spectroscopy with whole-body and partial-body counters shows a steadily rising upward trend over the last few years. This induced the ''Arbeitskreis Inkorporationsueberwachung'' of the association ''Fachverband fuer Strahlenschutz e.V.'' to organise a meeting for joint elaboration of a guide on recommended applications of this measuring technique, based on a review of existing experience and results. A key item on the agenda of the meeting was the comparative evaluation of the Ge semiconductor detector and the NaI solid scintillation detector. (orig./CB) [de

  11. Semi-portable whole body counter deployable during post-radiological accident

    International Nuclear Information System (INIS)

    Panchal, C.G.; Bansode, P.Y.; Vinod, M.; Sarade, Bhagyashree; Jain, R.K.; Jakati, R.K.; Pithawa, C.K.

    2012-01-01

    A versatile whole body counter with the state of art electronics has been indigenously designed and developed which can be readily deployed for use during nuclear emergency. This instrument is designed to quickly identify and quantify the activity of high energy photon emitters accumulated particularly in vital organs like thyroid, lungs besides the body of the victims of the radiological incident or accident. Special features of the instruments are swivel type detectors assembly mountable on a wall or table top and detachable collimator configurable to assess the internal contamination selectively to meet protective measures of the radiological accidents, mechanically rugged and functionally reliable to perform in contaminated environmental field conditions. (author)

  12. Importance of Intercomparison Exercises in Assessment of Internal Exposure by Whole-Body Counter

    International Nuclear Information System (INIS)

    Andrasi, A.

    2001-01-01

    Full text: Basic requirement for any kind of measurement is to check and prove the reliability and correctness of the measured results. Quality assurance programmes require several activities among which the participation in intercomparison exercises plays an important role. Since the determination of radioactive materials in the human body by whole-body counting technique implies many sources of uncertainties the reliability of calibration data and consequently the measured results have to be checked by participation in intercomparison quality control programmes. In these programmes mostly different kinds of phantoms simulating the human body are circulated among the participating laboratories, however sometimes contaminated persons are also subjects of intercomparison measurements. There are guidelines in several countries laid down concerning the requirements of whole-body counter measurements where the performance criteria for the relative bias, precision and minimum detectable amounts are formulated. These quantities are mostly the subject of intercomparison programmes. The whole body counter laboratory of the KFKI Atomic Energy Research Institute participated in intercomparison exercises several times in the last few years. The lessons learned during these activities helped in checking the capabilities of applied methods and measuring geometry as well as contributed in improving the accuracy of the measured results. A short overview on the previous international intercomparison exercises their main characteristics the results obtained and conclusions drawn are discussed in the paper with special attention to those in which also our laboratory participated. (author)

  13. Bases for calibration of whole body counters using anthropomorphic physical simulators

    International Nuclear Information System (INIS)

    Dantas, Bernardo Maranhao

    1998-01-01

    The quantification of radionuclides in the human body can be carried out through in vivo measurements performed in facilities generically called whole body counters. The calibration of such units is usually done by using physical anthropomorphic phantoms, which can be defined as artificial structures with geometrical characteristics and attenuation properties similar to the living tissues. This work presents the development of the phantoms necessary to the monitoring of the internal contamination by the radionuclides manipulated in Brazil. It also presents the procedures for the calibration of the detectors used for the in vivo measurements. The developed phantoms are applied in the determination of radionuclides deposited in specific organs, such as Th-232 and Am-241 in the lungs and skull, isotopes of iodine in the thyroid and photon emitters in the energy range from 100 to 3000 keV in the whole body. (author)

  14. Whole-body counters in Canada

    International Nuclear Information System (INIS)

    Letourneau, C.

    1986-08-01

    A compilation of whole-body counting existing across Canada was prepared by AECB (Atomic Energy Control Board) staff. This work was initiated so that AECB staff and other concerned parties would have this information readily available, especially during urgent situations. This report is to be used for reference purposes only, as it makes no attempt to judge the present state of the art of whole-body counting

  15. Calibration of a whole body counter and 'In Vivo' measurements for internal dosimetry evaluation in Chile, two years experience

    International Nuclear Information System (INIS)

    Pinones O, Osvaldo; Sanhueza M, Sylvia

    2008-01-01

    In Chile the internal Dosimetry evaluation have been doing for more than 20 years ago by 'in vitro' measurements, however the 'in vivo' measurements just have available for 2 years due to the installation, calibration and completion of a Whole Body Counter. The Whole Body Counter of the CCHEN, corresponds to the shielded room type (4.2 x 3.3 x 2.0 m), is located in the second subterranean of the North Wing of the building of Laboratories of the La Reina Nuclear Center in Santiago City, (3 meters under the ground). It is composed by 12 cm thickness walls of concrete, then successive layers of 2 mm of thickness with: lead, cadmium and copper, 1 cm of acrylic and finally 2 mm of wood. The measurement system is composed by: 2 detectors of NaI (Tl) of 8 x 3 inches (BICRON) that operate to 800 volts (+) and allow the detection of gamma emitters of high energy (>100 keV). It has the possibility of measurement fixes (thyroid) and route (whole body) using for it a pneumatic system that allows the displacement of the detectors on a central axis. It has two positions of location of the detectors, one of 90 degrees with respect to the central axis when the system is in rest or entrance retirement of patient and one of 45 degrees approximately when the measurement is made. For the calibration, two simulators were used: Thyroid simulator from the IRD (Brazil), and Whole Body, BOMAB simulator ( 133 Ba, 137 Cs and 60 Co) from the IAEA. 10 measurements of 300 seconds each one per geometry and different detector-patient distances were done: 20.0; 25.0; 30.0; 37.7 and 101.1 cm (considering high level incorporations). For the analysis of spectrum, software 'Genie 2000' and for the calculation of dose, program 'AIDE' obtained through ARCAL RLA/9/049 'Harmonization of Procedures of Internal Dosimetry', were used. To date, 300 measurements have been made and the results were used for the evaluation of the internal Dosimetry of the Professional Exposed Workers (PEW), but also to improve

  16. A simple calibration of a whole-body counter for the measurement of total body potassium in humans

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El-Fiki, S.A.; El-Enany, N.; Youssef, S.K.; Aly, A.M.; Abbas, M.T.

    1992-01-01

    A simple calibration procedure for the Inshas whole body counter for evaluating total body potassium has been adopted. More than 120 Egyptian employees in the Nuclear Research Center (N.R.C.) were studied for their total body potassium (TBK). The potassium values were found to have an average of 2.85±0.57 g K kg -1 body weight for males and 2.62±0.52 g K kg -1 for females, which are higher than the recommended value given for reference man by ICRP. The TBK varied directly with body build index and is slightly sex dependent (Author)

  17. Optimization of whole-body simulator for photon emitters in the energy range 100 to 3000 KeV

    International Nuclear Information System (INIS)

    Dantas, Bernardo M.; Rosales, Geovana O.

    1996-01-01

    The calibration of the detection system for the in vivo determination of uniformly distributed radionuclides emitting photons in the energy range of 100 to 300 KeV requires the use of phantoms with dimensions close to the human body, in which known amounts of radionuclides are added. After the measurement of those phantoms, the calibration curves, channel x energy and energy x efficiency, are constructed. This type of phantom has been continuously optimized at the IRD-CNEN whole body counter with the objective of approximating its characteristics as close as possible to the standard man proposed in the ICRP 23. Furthermore, it has been tried to obtain a safe structure in terms of leakage and also of low cost. (author)

  18. Development of the Discrimination Programs between the Internal and External Radioactive Contamination of Workers Using a Whole Body Counter

    International Nuclear Information System (INIS)

    Kong, T. Y.; Kim, H. G.; Lim, S. N.; Kim, H. J.; Jin, H. H.; Lee, S. G.; Park, S. C.

    2006-01-01

    A whole body counter (WBC) is used to identify and measure the radioactivity in the body of human beings in a nuclear power plant (NPP). In domestic NPPs, several whole body counters are in operation to monitor the internal radioactive contamination of workers. All workers take a whole body counting after radiation works if there is high possibility of radioactive contamination or the radioactivity is detected by portal monitoring. It is, however, found that the external contamination is occasionally estimated as the internal radioactive contamination. In this case, the worker is recommended to take showers for the decontamination of skin and take a whole body counting again. Although the detected radioactivity is reduced remarkably after several decontaminations, confirmed as the external contamination, it is determined finally as an internal contamination if the radioactivity is still detected in the body of worker. The amount of detected radioactivity can be much higher than that of the expected for this mistaken contamination since the radioisotopes attached to skin come to be close to the detectors of WBC. Finally, this makes not only the misjudgment of the external contamination as the internal contamination, but also the excessively conservative estimation of radioactive contamination. In this study, several experiments were carried out to set up the discrimination program between the internal and external radioactive contamination using the humanoid phantom and a whole body counter. After the analysis of experimental results, we found that the use of front and backside counts could be applied to the discrimination of the external contamination and the ratio of detected radioactivities between front and backside counts was more than about factor 2 for the external contamination

  19. Efficiency determination of whole-body counters by Monte Carlo method, using a microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, J.M.

    1987-01-01

    A computing program using Monte Carlo method for calculate the whole efficiency of distributed radiation counters in human body is developed. A simulater of human proportions was used, of which was filled with a known and uniform solution containing a quantity of radioisopes. The 99m Tc, 131 I and 42 K were used in this experience, and theirs activities compared by a liquid scintillator. (C.G.C.) [pt

  20. The ORNL whole body counter

    International Nuclear Information System (INIS)

    1988-01-01

    This report is a non-technical document intended to provide an individual about to undergo a whole-body radiation count with a general understanding of the counting procedure and with the results obtained. 9 figs

  1. Experimental study of absorption of iron in foods using whole-body counter

    International Nuclear Information System (INIS)

    Nakamura, Tadamitsu

    1978-01-01

    Male rats of Wistar strain which showed normal hematological picture were given 59 Fe-labeled foods orally, and the iron absorption rate was determined by an animal whole body counter. When 59 Fe was given in a mixture with each of gruel, spinach, cow's milk, the yolk, and the yolk with orange juice, the iron absorption rates in each food were 9.4%, 8.9%, 6.6%, 10.8% and 7.2% respectively. None of these foods seemed to inhibit the 59 Fe absorption. When 59 Fe was given in a mixture with chicken, the iron absorption rate was 35.8%. This result suggested that the chicken promoted the 59 Fe absorption. When the yolk labeled in vivo with 59 Fe was given, the iron absorption rate was 4.9%. If the yolk labeled in vitro was used, the absorption rate was 10.8%. When the yolk labeled in vivo with 59 Fe was given with orange juice, the iron absorption rate was 13.3%. If the yolk labeled in vivo with 59 Fe was given, the absorption rate was 7.2%. Orange juice had no effect on the iron absorption when the yolk labeled in vitro was used. After chicken eggs labeled in vivo with 59 Fe was given to children, the iron absorption was determined by a whole body counter; the rate averaged 5.4 in the children without anemia and 24.7 in those with anemia. (Ueda, J.)

  2. 35 years of existence of whole-body counter in the Czech Republic - experiences and prospects

    International Nuclear Information System (INIS)

    Malatova, I.; Foltanova, L.; Cespirova, I.

    1998-01-01

    A whole-body counter was built up in the Czech Republic in 1962, this at the then Institute of the Hygiene of Labour and Occupational Diseases. The shielding was made of steel plates taken from Tiger tanks which remained in the country as aftermath of World War II. The detecting and evaluating parts of the counter were upgraded gradually. The original 4 scintillator detectors (10.16 cm x 12.7 cm in size) were replaced with an HPGe semiconductor detector exhibiting a roughly fifty-fold better resolution, owing to which radionuclide activities can be determined in complex matrices. Currently, the whole-body counter is equipped with a high-purity Ge detector displaying a relative efficiency of 120%, special detectors for low-energy gamma radiation, so-called LEGe detectors which are employed during the determination of radionuclides in the individual organs. The facility is applied to the monitoring of internal contamination in persons handling unsealed sources, monitoring in cases of suspect accidents associated with internal contamination of humans, as well as to the determination of internal contamination in epidemiological studies. In the past, a group of persons contaminated with radioactive fluorescent dyes which contained 226 Ra and 90 Sr, and a group of patients with applied thorotrast were also examined. Currently, methods which are under development are aimed at the determination of 210 Pb in the skulls of people who have been exposed to elevated radon concentrations in dwellings for a long time, and the determination of 241 Am in human bodies and their individual organs

  3. Development of sealed sheet sources for calibration of whole-body counters

    International Nuclear Information System (INIS)

    Miyamoto, Mai; Ishigure, Nobuhito; Ogata, Yoshimune; Narita, Norihiko; Kawaura, Chiyo; Nakano, Takashi

    2009-01-01

    Whole body counters are usually calibrated with the aid of a whole body phantom assembled with simply-shaped plastic vessels that are filled with an aqueous solution of the relevant radioisotopes. Most vessel-type phantoms represent only a human body in which radioisotopes are homogeneously distributed, whereas the radioisotopes in vivo are sometimes localized to specific organs. Each set of the vessels is usually applicable only to a specific combination of radioisotopes, because the replacement of radioisotopes requires troublesome procedures. Possible leakage of the solution is another disadvantage of the vessel-type phantom. The authors are developing a new-type calibration phantom that is free from these disadvantages, in which sealed sheet sources are sandwiched between sections of a sliced anthropomorphic phantom. This paper describes a method to prepare sealed sheet sources for this calibration phantom. Instead of γ-ray emitters a pure β-ray emitter 32 P was used. This isotope is suitable for autoradiography and is easy to handle as its half-life is relatively short. An ink-jet printer was used to spread the solution of 32 P mixed with ink on a sheet of paper. The surface concentration of radioactivity was regulated by the function of color density adjustment of an image processing software. The radioisotope-printed paper was laminated for sealing. Through the measurement of surface concentration of radioactivity with a liquid scintillation counter, the autoradiographical investigation of the pattern of the radioactivity distributed on the sheet sources, the immersion test of the sealed sheet sources and the monitoring of the concentration of 32 P in air during the printing, it was demonstrated that sealed sheet sources for the calibration phantom can be prepared safely by the method described in this paper. Furthermore, by using sheet sources of 99m Tc prepared as a trial it was confirmed that discrete arrangement of sheet sources in a phantom at a

  4. Radiological Emergency Preparedness using Old ORTEC Whole Body Counter

    International Nuclear Information System (INIS)

    Badawy, W.M.

    2012-01-01

    During a radiological emergency (RE) a large number of occupational and public may be exposed externally and to a number of radionuclides internally as a result of inhalation or injection. The radiological effect is directly proportional to the time of exposure and the activity of the contaminant materials. The main task of this paper is to show the emergency preparedness capability of using the old ORTEC whole body counter (WBC). In case of a nuclear accident ORTEC WBC is ready for use to estimate the radioactivity which inhaled or digested with food, as well as in case of medical exposure in general and nuclear medicine in particular. The present study showed that the duration time to make analysis for only one individual is about 25 min. Hence 57 individuals are monitored per day. Consequently, old ORTEC WBC is effective tool in field of research and limited use for radiological and nuclear emergencies

  5. Conversion of a whole-body counter into a low-level whole-body scanning system controlled by a process computer

    International Nuclear Information System (INIS)

    Hamann, C.M.

    1976-01-01

    The report outlines the status of a research project in which a whole body counter with fixed geometries is converted into a scanning type system. The purpose of the project is the development of an adaptive system controlled by a process computer. The home-made scanning mechanics is explained, and a description is given of the advantages and the problems inherent in the application of step motors. For economic reasons no CAMAC system was purchased; instead, interfaces from and to the computer were designed which allowed the process periphery to be connected and operated. The inexpensive and relatively simple home-made designs are outlined; the example quoted refers to the conversion of a teletype output into a fast electronic data interface. (orig./ORU) [de

  6. Whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, G A; Kosterev, V V

    1975-01-24

    A counter for detecting radiation of a man (CRM) is described, which consists of two measuring converters and a recording device. In order to obtain data on spatial distribution of a gamma-radiating nuclide studied, a fixed collimator and a mobile coder made of separate slit elements are placed between the measuring converters and an object investigated.

  7. 35 years of existence of a whole-body counter in the Czech Republic - experience and prospects

    International Nuclear Information System (INIS)

    Malatova, I.; Foltanova, S.; Cespirova, I.

    1998-01-01

    A whole-body counter was built up in the Czech Republic in 1962, this at the then Institute of the Hygiene of Labour and Occupational Diseases. The shielding was made of steel plates taken from Tiger tanks which remained in the country as aftermath of World War II. The detecting and evaluating parts of the counter were upgraded gradually. The original 4 scintillator detectors (10.16 cm x 12.7 cm in size) were replaced with an HPGe semiconductor detector exhibiting a roughly fifty-fold better resolution, owing to which radionuclide activities can be determined in complex matrices. Currently, the whole-body counter is equipped with a high-purity Ge detector displaying a relative efficiency of 120%, special detectors for low-energy gamma radiation, so-called LEGe detectors which are employed during the determination of radionuclides in the individual organs. The facility is applied to the monitoring of internal contamination in persons handling unsealed sources, monitoring in cases of suspect accidents associated with internal contamination of humans, as well as to the determination of internal contamination in epidemiological studies. In the past, a group of persons contaminated with radioactive fluorescent dyes which contained 226 Ra and 90 Sr, and a group of patients with applied thorotrast were also examined. Currently, methods which are under development are aimed at the determination of 210 Pb in the skulls of people who have been exposed to elevated radon concentrations in dwellings for a long time, and the determination of 241 Am in human bodies and their individual organs

  8. Evaluation of fat-free mass by whole-body counter in Japanese healthy young adults

    International Nuclear Information System (INIS)

    Morita, N.; Takamura, N.; Murakami, T.; Jo, O.; Aoyagi, K.; Yamashita, S.; Okumura, Y.

    2007-01-01

    Whole-body counters (WBCs) are special instruments for measuring internal irradiation doses and are usually housed within or around nuclear facilities in the event of unexpected radiation emergencies. As a substantial proportion of total body potassium (TBK) is found in fat-free mass (FFM), FFM volume can be predicted from WBC-measured 40 K. We screened TBK in Japanese healthy young adults using a WBC and found strong linear correlations between TBK and lean body mass (LBM) and body mass index (r = 0.97, P<0.01 and r = 0.47, P<0.01, respectively). Multiple linear regression analysis, following adjustments for sex, indicates that only LBM has a significant correlation with TBK (P<0.01). These results strongly support the feasibility of using WBCs for estimating FFM. (authors)

  9. Using a whole body counter to attract a younger generation to radiation and radiation protection topics

    International Nuclear Information System (INIS)

    Breustedt, B.; Mohr, U.; Bohnstedt, A.; Knebel, J.U.

    2010-01-01

    Currently there is a lack of young academics in the nuclear field especially in the field of radiation protection RP. One of the reasons is the very small number of students in the so called STEM subjects (science, technology, engineering and mathematics) which distribute among the different topics in these fields. One important task to overcome the foreseeable shortage of RP professionals is to attract pupils to this field. In routine monitoring the whole body counter of the Institute of Radiation Research (ISF) is used to identify and quantify radioactive materials that are incorporated in the human body using the technique of gamma spectroscopy. The in-vivo monitoring lab participates in activities for pupils at school level, e.g. Kinderuniversitaet, practical studies of secondary level pupils and 'Girls day'. Pupils that come to the lab are ages 14 to 18. The whole body counter is an optimal tool for these children to experience (natural) radioactivity and radiation protection issues. First pupils get a short introduction on radioactivity and gamma spectroscopy at a level adjusted to their current knowledge. After this they are measuring themselves in the whole body counter. A routine measurement of 300 s is able to show the natural occurring K-40 in their bodies. After their own measurements they do calibration measurements using a bottle phantom with a set up adjusted to their own body weights. The bottle phantom is filled with a potassium chloride (KCl) solution and contains no other radioactivity than the natural K-40 content of the KCl. Thus no further radiation protection measures need to be taken for using this phantom. A simple Excel-Sheet is then used to estimate their own K-40 activity by comparing the spectra of their measurement to the ones of the calibration measurements. This 'hands on' experience and the connection of radiation and their own bodies often is a 'eureka' effect and opens discussion on preconceptions of radiation and the need of RP

  10. Parameters of a simple whole body counter and thyroid monitor established at the Dresden Felsenkeller underground laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sahre, P [Rossendorf Nuclear Engineering and Analytics, Inc., Dresden (Germany); Schoenmuth, T [Rossendorf Nuclear Engineering and Analytics, Inc., Dresden (Germany)

    1997-03-01

    At the Rossendorf Nuclear Engineering and Analytics Inc. a simple whole body counter and an iodine-thyroid monitor are used for measuring the internal contamination of workers. There is no shielding chamber in both cases. By using the chamber at the Dresden Felsenkeller underground laboratory the lower limit of detection could be improved by a factor of about 3 for whole body counting and by a factor of 2,5 for thyroid monitoring (I 131, I 125). Concerning the lower limit of detection the applicability of the German standard DIN 25 482 implemented in the Gamma-Vision software packadge is discussed in the paper. (orig.)

  11. Intercomparison of Finnish and Russian whole-body counters used for the determination of 137Cs body burden in reindeer-herding populations

    International Nuclear Information System (INIS)

    Rahola, T.; Tillander, M.

    1995-01-01

    Intercalibration is a very important quality control in whole-body counting, as the human body is a very difficult ''sample'' to calibrate for. In 1994 the Finnish Centre for Radiation and Nuclear Safety (STUK), the Laboratory of Radiochemistry of the University of Helsinki and the Institute of Radiation Hygiene (IRH) of St. Petersburg agreed to undertake the first Finnish-Russian intercalibration project for whole-body counters. The monitoring of body burdens of indigenous inhabitants in the far north of Russia, from the Kola Peninsula to Chuhodka, has been the responsibility of the ISH since 1960; the above-.mentioned Finnish institutes have monitored reindeer breeders in Finnish Lapland since 1961. The intercalibration was done in the field by measuring the same persons with both systems in Finnish Lapland and in the Kola Peninsula. Mean body burdens in the reindeer-herding population in the areas of current interest are presented in the present paper. 7 refs., 3 figs., 1 tab

  12. A shielding chamber for the Rossendorf whole-body counter; Eine Abschirmkammer fuer den Rossendorfer Ganzkoerperzaehler

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, Stephan; Loehnert, Daniela [VKTA - Strahlenschutz, Analytik und Entsorgung Rossendorf e.V., Dresden (Germany).; Schreiber, Wolfgang [Ingenieurbedarf G. Schoene und W. Schreiber GmbH, Radeberg (Germany)

    2017-08-01

    A large part of radionuclides to be evaluated in the frame of incorporation monitoring are gamma emitter that can be directly measured (in vivo). In order to reach the required detection limits for the relevant radionuclides in the short measuring time high effort is necessary for the shielding of natural radioactivity. The contribution describes planning, construction and installation of the shielding chamber for the new in vivo whole body counter in Rossendorf. First experiences and preliminary results are discussed.

  13. Body counter

    International Nuclear Information System (INIS)

    Koeppe, P.

    1975-01-01

    The paper gives a survey on some applications of the whole body counter in clinical practice and a critical study of its application as a routine testing method. Remarks on the necessary precautions are followed by a more detailed discussion of the determination of the natural potassium content, the iron metabolism, the vitamin B12 test, investigations of the metabolism of the bone using 47 Ca and 85 Sr, investigations with iodine and iodine-labelled substances, clearance investigations (in particular the 51 Cr EDTA clearance test), as well as the possibilities of neutron activation in vivo. (ORU/AK) [de

  14. Reconstruction of a whole-body counter into a process computer-controlled low-level whole-body scanner

    International Nuclear Information System (INIS)

    Hamann, C.

    1975-01-01

    A report is given on the state of the research project to reconstruct our whole-body counter with solid geometries into a scanning type one. The object is to develop a process computer controlled 'adaptive system'. The self-built scan mechanics are explained and the advantages and problems of applying stepping motors are gone into. A stepping motor coordinates control is presented. As the planned scanner and the process computer form a digital controlled system, all theoretical and actual values as well as the control orders from the process computer must be directly controllable. A CAMAC system was not used for economical reasons, the process periphery was made controllable by self building of interfaces to and from the computer. As example, the available multi-channel analyzers were converted to external controlling. The price-moderate and relatively simple self-built set-up are outlined and an example is given of how a TELETYPE version is reconstructed into a fast electronic interface. A BUS-MULTIPLEX system was developed which generates all necessary DI/DO interfaces out of one DI and DO address of the process computer only. The essential part of this system is given. (orig./LH) [de

  15. Practical methods for the functioning evaluation of the whole body counter system Accuscan II of the ININ

    International Nuclear Information System (INIS)

    Alfaro L, M. M.; Ramirez J, F. J.; Mondragon C, L.

    2013-10-01

    The whole body counter system Accuscan II of the Instituto Nacional de Investigaciones Nucleares (ININ), was designed and built to quantify and to measure radionuclides fission product as well as gamma emitters, with a maximum sensibility of less than 10 n Ci for cobalt 60 at one time of counting of 5 minutes. The system has two detectors of Ge(Hp) with Beryllium window to a relative efficiency of 25% in a counting configuration of vertical scanning, this configuration gives a plane response of constant efficiency. In this work some practical methods developed in the Internal Dosimetry Laboratory to carry out the functioning evaluation of the whole body counter system Accuscan II of the ININ are described. With the obtained results of this evaluation we can decide fine adjustments will be necessary for the optimization of the equipment operation. The evaluation of this equipment was especially necessary, due to its 21 years-old antiquity and for the gradual changes that has in its functioning. The equipment is intrinsically a gamma spectrometry system and some described experiences could be applied too in other gamma spectrometry systems. (Author)

  16. Studies of Se-75 labelled bile acid analogue absorption in different forms of gastrointestinal diseases using a whole body counter

    International Nuclear Information System (INIS)

    Grebe, S.F.; Sattler, E.L.; Rinkenberger, C.; Bodenmueller, D.; Grebe, S.K.G.; Mueller, K.D.; Mueller, H.; Faengewisch, G.L.; Heckers, H.; Steckenmesser, R.

    1996-01-01

    It is possible to detect disturbances of bile acid absorption using a whole body counter after administration of Se-75 labelled bile acid analogues. We scrutinized the benefit of a modification of the test method. We investigated 77 patients with different forms of a gastrointestinal disease. After application of Se 75 homotaurocholic acid we measured patient-activity up to 7 days later including whole-body profile scans in the first 6 h. The fractional retention after 7 days was between 20 and 67%. In cases of impaired absorption it was below 12%. Patients with liver diseases and afer cholecystectomy (without bile acid resorption disturbance) showed normal values. Patients with Crohn's disease of the ileum or with intestinal ileas by-pass or with colestyramine treatment or with disturbance of vitamin B12-absorption or with cystic fibrosis showed a disturbance of bile acid absorption. The normal whole-body half-life was more than 2.8 days. The 24 and 72 h values were 62 and 31% in cases with normal absorption. Smaller values are signs of bile acid malabsorption. Impulse rates measured with the whole body counter are of an order of magnitude that allows to reduce the usually administered dose of 37 kBq to 9.25 kBq. This is an efficient method to detect disturbances of bile acid absorption. The usually adminstered activity of 37 kBq can be reduced to 9.25 kBq. (orig./MG) [de

  17. Results of the internal contamination measurements performed after Chernobyl accident by means of Casaccia whole body counter

    International Nuclear Information System (INIS)

    Rampa, E.; Santoni, G.; Di Pietro, S.

    1987-01-01

    Direct measurements of internal contamination were carried out in human subjects following the nuclear accident of Chernobyl. The Whole Body Counter facility operated by Dipartimento Protezione Ambientale e Salute dell'Uomo, Divisione Scienze Ambientali, Centro Ricerche Energia - C.R.E. - Casaccia (Rome) was utilized. This investigation was continued until December 31, 1986. The subjects were either resident of the Rome metropolitan area or Italian citizens returning from East European Countries. The report present the data regarding 131 I in the thyroid and 134 Cs and 137 Cs in the whole body. An ingestion or inhalation of these radionuclides is also calculated. The results of this study should contribute to a better evaluation of the theoretical models for the transfer of radionuclides from the environment to man

  18. Calibration of whole-body counters for transuranic radionuclides by using total-body donations to the United States Transuranium Registry

    International Nuclear Information System (INIS)

    Palmer, H.E.; Heid, K.R.; Breitenstein, B.D.; Durbin, P.W.; McInroy, J.F.

    1985-01-01

    One of the many benefits of the whole-body donation programme of the United States Transuranium Registry is the calibration of whole-body counters by measuring a donated body containing radioactivity before radiochemical analysis of the body occurs. These measurements have provided the best existing calibration factors for measuring 241 Am and 239 Pu in the skeleton of living people. In one case where the body contained an easily measurable quantity of 241 Am, the 241 Am content was found to be the same for identical bones on the right and left sides of the body. The bones from the right side of the body and every other vertebrae were radiochemically analysed and the bones from the left side were reserved. These latter have a known quantity of naturally distributed 241 Am based on the analysis of bones from the right side. These reserved bones are being incorporated into tissue equivalent body parts for future calibrations and interlaboratory comparisons. The measurements on the total body and the reserved bones have already been very useful in determining the contribution of skeletal activity to that of lung measurements and determining a calibration factor for measuring 239 Pu deposited in the skeleton. In the future it is planned to periodically make in vivo measurements on those people participating in the total-body donation programme so that calibration factors can be obtained for lung and liver content after subsequent analysis of these tissues. (author)

  19. Efficiency determination of whole-body counter by Monte Carlo method, using a microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, Jose Maria

    1986-01-01

    The purpose of this investigation was the development of an analytical microcomputer model to evaluate a whole body counter efficiency. The model is based on a modified Sryder's model. A stretcher type geometry along with the Monte Carlo method and a Synclair type microcomputer were used. Experimental measurements were performed using two phantoms, one as an adult and the other as a 5 year old child. The phantoms were made in acrylic and and 99m Tc, 131 I and 42 K were the radioisotopes utilized. Results showed a close relationship between experimental and predicted data for energies ranging from 250 keV to 2 MeV, but some discrepancies were found for lower energies. (author)

  20. Study of vitamin B/sub 12/ absorption by a whole-body counter (plastic). I. The fundamental considerations

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, R; Furumatsu, C [Kyoto Univ. (Japan). Faculty of Medicine

    1975-08-01

    An absorption test of vitamin B/sub 12/ was studied by using the whole body spectrometer (plastic) in a low background room. Four plastic scintillation probes were set under the bed. Each plastic scintillation probe contains a 50x50x15 cm/sup 3/ scintillator and four photomultiplier tubes. Each subject was measured in supine and prone positions and the mean was used. Measurement was made before (body background), 35 minutes after (100%), and again 7 days after the oral administration of 0.17 to 0.2 ..mu..g(below 0.16 ..mu..Ci) /sup 60/Co-B/sub 12/ or of 0.2 ..mu..g(below 0.4 ..mu..Ci) /sup 58/Co-B/sub 12/. No meal or medicine was given at least 2 hours after the oral uptake of radioactive B/sub 12/. To correct for the radioactive decay and any counter instability, all measurements were corrected using a standard source. The results of B/sub 12/ absorption were expressed as the retention percentage of the labeled B/sub 12/ within the body on the seventh day. Present methods of measuring intestinal absorption of radioactive B/sub 12/ include measurements of the radioactivity (1) in the feces, (2) in the urine, (3) in the serum, or over the liver projection. While all these methods give clinically valuable results, B/sub 12/ absorption is determined most accurately by direct measurement of the amount remaining in the body with a whole-body counter after the unabsorbed radio-B/sub 12/ is excreted in the feces. It is more quantitative and simpler than the Schilling test and permits the measurement ofradioactive B/sub 12/ at a considerably lower level than the maximum permissible body burdens.

  1. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  2. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tetsuo [Chiba Univ. (Japan). Inst. for Training Radiological Technicians; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-08-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m{sup 2}) and adjusted by age and sex of healthy persons. The R value was 100.65{+-}9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24{+-}11.22%, chronic hepatitis; 95.74{+-}11.24%, hyperthyroidism; 99.37{+-}10.8%, periodic paralysis; 82.0{+-}9.01%, Barter's syndrome; 93.99{+-}9.86%, myasthenia gravis; 97.34{+-}6.42% and hypo-potassemia; 90.64{+-}11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78{+-}11.5%, 99.22{+-}8.88%, 96.64{+-}12.73%, 98.5{+-}9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  3. Measurements of the total-body potassium contents. Application of reference value with the whole-body counter

    International Nuclear Information System (INIS)

    Yamamoto, Tetsuo; Saegusa, Kenji; Arimizu, Noboru; Kuniyasu, Yoshio; Itoh, Hisao

    2001-01-01

    The total-body potassium contents were measured in 405 healthy volunteers and 186 patients with whole body counter in Chiba University Hospital. The total-body potassium contents was expressed by the reference value (R value). The R value was calculated as measured potassium contents (g) divided by the body surface area (m 2 ) and adjusted by age and sex of healthy persons. The R value was 100.65±9.22% in 405 healthy volunteers. Those of each disease were as follows: liver cirrhosis; 94.24±11.22%, chronic hepatitis; 95.74±11.24%, hyperthyroidism; 99.37±10.8%, periodic paralysis; 82.0±9.01%, Barter's syndrome; 93.99±9.86%, myasthenia gravis; 97.34±6.42% and hypo-potassemia; 90.64±11.76%, respectively. The R values of other diseases such as uterine cancer, breast cancer, anemia, hypertension were 97.78±11.5%, 99.22±8.88%, 96.64±12.73%, 98.5±9.63% respectively. Fourteen patients showed especially lower R values under 75%. These were 1 liver cirrhosis, 3 hypertension, 1 diabetes mellitus, 3 hypo-potassemia, 1 periodic paralysis, 2 Barter's syndrome, 2 chemical poisoning, and 1 breast cancer. Follow-up study was performed in some patients with the lower R values. The result of follow-up study showed that there was a relationship between improvement of symptoms and increase of total body potassium contents. (author)

  4. Detection of metastatic thyroid carcinoma through whole body counting

    International Nuclear Information System (INIS)

    Novenario, H.S.; Pascacio, F.M.; Cruz, Benjamin de la; Anden, A.B.

    Whole body counters are not only used in measuring radioactivity in the body for radiation protection purposes but also in the measurement of iron absorption, body potassium and cesium, chronic blood loss, and also in the determination of the effectiveness of surgery, thyroid hormone and radioactive iodine therapy in thyroid carcinoma. This report deals with our experience in the use of a shadow-shield whole body counter in the determination of I-131 uptake by metastatic lesions of cancer of thyroid after total thyroidectomy and ablation therapy with I-131. This study was undertaken jointly by the Department of Nuclear Medicine, Veterans Memorial Hospital and the Biomedical Research Division of the Philippine Atomic Energy Commission. Preliminary results indicate that the 22 patients who underwent whole body counting after total thyroidectomy I-131 ablation therapy, 9 patients had elevated percentage retention of I-131, 10 patients with normal values and 3 patients with rising values. Foci of I-131 concentration in those with elevated and rising percentage concentration values were seen in the thyroidal bed scintiscans, while the 10 patients with normal values had negative scintiscans. The results of our observations confirm the results obtained by other workers abroad. Our preliminary results indicate that with the use of whole body counters a sensitive method of assessing whether functioning metastatic lesion of cancer of the thyroid still exist after total thyroidectomy and I-131 ablation therapy can be provided. (author)

  5. Evaluation of the dose committed as based on direct measurements with the Whole Body Counter

    International Nuclear Information System (INIS)

    Meladani, C.; Castellani, C.M.; Battisti, P.; Tarroni, G.

    1989-01-01

    During normal working activities or in accidental situations, when the introduction of radioactive gamma emitters is non-negligible amount, accurate determination of effective committed dose equivalent based on direct measurements of the internal contamination cannot be avoided. Internal contamination measurements carried out by Whole Body Counter and the application of dosimetric and metabolic models as proposed by ICRP Publication 30 allow the intakes and committed dose equivalents to be evaluated. This paper presents the evaluation methodologies of committed dose equivalent both for istantaneous and extended contaminations. Furthermore, some advice about useful, opportune modes and time uncertainties due to the application of generalized models to particular situations, are also reported. On the basis of the Chernobyl experience, the general criteria for the chice and size of homogeneous groups of individuals to be measured, are finally submitted with a view to collecting the necessary radiation protection information concerning contamination of a part or a whole population

  6. Results of substitution of the Nal by a Ge detector in a simple shadow shield whole body counter

    International Nuclear Information System (INIS)

    Sahre, P.; Schoenmuth, T.; Thieme, K.

    1997-01-01

    Since 1976 a whole body counter (WBC) has been used at the Rossendorf Research Centre for measuring the internal contamination of workers. The WBC with the Germanium detector is given schematically and visually. The WBC is a shadow shield type with a tilted chair having only one detector. Table 1 contains the parameters of the WBC. It can be seen that the WBC is a simple counter. Therefore, taking into account the experiences of McCurdy, a lot of improvements were expected form the simple substitution of a HP Germanium detector for a NaI (TI) detector, i.e. despite a decrease in the sensitive detection volume, an enhancement of all quantifiable results (e.g. lower limit of detection and time for analysis of the spectrum) and above all the reliability and automation of nuclide identification were expected. (orig./SR)

  7. Results of substitution of the Nal by a Ge detector in a simple shadow shield whole body counter

    Energy Technology Data Exchange (ETDEWEB)

    Sahre, P.; Schoenmuth, T. [Nuclear Engineering and Analytics Inc. Rossendorf, Dresden (Germany); Thieme, K. [Amersham Buchler Ltd. und Co., Braunschweig (Germany)

    1997-12-01

    Since 1976 a whole body counter (WBC) has been used at the Rossendorf Research Centre for measuring the internal contamination of workers. The WBC with the Germanium detector is given schematically and visually. The WBC is a shadow shield type with a tilted chair having only one detector. Table 1 contains the parameters of the WBC. It can be seen that the WBC is a simple counter. Therefore, taking into account the experiences of McCurdy, a lot of improvements were expected form the simple substitution of a HP Germanium detector for a NaI (TI) detector, i.e. despite a decrease in the sensitive detection volume, an enhancement of all quantifiable results (e.g. lower limit of detection and time for analysis of the spectrum) and above all the reliability and automation of nuclide identification were expected. (orig./SR)

  8. Measurements of whole-body radioactivity in the UK population

    International Nuclear Information System (INIS)

    Fenwick, J.D.; Boddy, K.; McKenzie, A.L.; Oxby, C.B.

    1992-01-01

    A national survey of whole-body radioactivity was undertaken. A mobile whole-body counter visited collaborating Medical Physics Departments and Hospitals in England and Wales. Data were also obtained from an installed whole-body counter at the West Cumberland Hospital, Whitehaven, and from a control site at Addenbrooke's Hospital, Cambridge. 1657 volunteer members of the public were measured, including 162 children. 36% of volunteers had been measured in a similar survey 2 years earlier, and showed between a two and five fold reduction in body radiocaesium. No radiocaesium was detected in 54% of people measured. Measurements showed a progressive fall over the course of the study, reaching a baseline of 0.3 Bq 137 Cs/gK. In 1989, the additional radiation dose incurred from radiocaesium varied from a maximum of 4.1 μSv in Cumbria to 1.5 μSv in the South East, compared with the average annual radiation dose of 2500 μSv due to all other causes. No other gamma-emitting radionuclides were found. Results are consistent with Chernobyl as the source of the radiocaesium detected. (author)

  9. Whole-body counting 1990

    International Nuclear Information System (INIS)

    Strand, P.; Selnaes, T.D.

    1990-01-01

    In order to determine the doses from radiocesium in foods after the Chernobyl accident, four groups were chosen in 1987. Two groups, presumed to have a large consumption of food items with a high radiocesium content, were selected. These were Lapp reindeer breeders from central parts of Norway, and hunters a.o. from the municipality of Oeystre Slidre. Two other groups were randomly selected, one from the municipality of Sel, and one from Oslo. The persons in these two groups were presumed to have an average diet. The fall-out in Sel was fairly large (100 kBq/m 2 ), whereas in Oslo the fall-out level was low (2 kBq/m 2 ). The persons in each group were monitored once a year with whole-body counters, and in connection with these countings dietary surveys were preformed. In 1990 the Sel-group and the Lapps in central parts of Norway were followed. Average whole-body activity in each group is compared to earlier years's results, and an average yearly effective dose equivalent is computed. The Sel-group has an average whole-body activity of 2800 Bq for men, and 690 Bq for women. Compared to earlier years, there is a steady but slow decrease in whole-body activities. Yearly dose is calculated to 0.06 mSv for 1990. The Lapps in central parts of Norway have an average whole-body content of 23800 Bq for men and 13600 Bq for women. This results in an average yearly dose of 0.9 mSv for the individuals in the group. Compared to earlier years, the Lapp group show a decrease in whole-body contents since 1988. This decrease is larger among men than women. 5 refs., 8 figs., 6 tabs

  10. Mechanical component design for upgrading of whole body counter ND7500

    International Nuclear Information System (INIS)

    Norizam Saad; Mohamad Annuar Assadat Husain; Ishak Mansor

    2007-01-01

    The Whole Body Counter (WBC) ND7500 is a bed type counting system that used for measuring radionuclide in the entire human body. Malaysian Nuclear Agency has this system, which savaged from Institute of Medical Research (IMR) in 1987. This system consists of a nuclear counting system and mechanical system that totally inoperable due to its counting system failures. In April 2003, both counting system and the mechanical system were tested. The mechanical component is working properly but needs some readjustment for the bed movement while for the counting system, only detectors can work but with a poor detecting capability. During IAEA expert visits on July 2003, both detectors were verified cannot be use any longer due to poor resolution and aging factor and a single (3 x 5 x 16) inches rectangular NaI(Tl) detector was then purchased in the end of 2004 to replace (3 x 5) inches cylindrical Na(Tl) detectors. The existing shielding cannot accommodate this new (3 x 5 x 16) inches dimension and the (5 x 16) inches detecting area. Therefore, shielding modification has been done based on effective detecting area and positioning test results. A new detector's entrance and detector stage were built at the bottom shielding. A new features, which is a detectors protection also been developed for detector safety. This upgrading task successfully accomplished as from experimental the design of positioning component can make system operated easily and also can give a good results to meets user's requirements. (Author)

  11. A Study on the Method to Discriminate Between the Internal and External Radioactive Contamination Using Whole Body Counter

    International Nuclear Information System (INIS)

    Kong, T. Y.; Kim, H. G.; Yang, H. Y.; Kang, D. W.; Lim, S. N.; Kim, H. J.; Jin, H. H.; Lee, S. G.; Park, S. C.

    2006-01-01

    Whole Body Counter (WBC) is used to identify and measure the radioactivity in the body of human beings in a nuclear power plants (NPPs). In domestic NPPs, it is prescribed that all workers should take a whole body counting after radiation works if the possibilities of radioactive contamination exist or the radioactivity is detected by a portal monitoring. It is, however, found that the external skin contamination is occasionally estimated as the internal radioactive contamination. In this case, the worker assumed to be detected is recommended to take showers for the decontamination of skin and take a whole body counting again. Although the detected radioactivity is reduced remarkably after several decontaminations, confirmed as the external skin contamination, it is determined finally as an internal exposure if the radioactivity is still detected in the body of worker. The amount of detected radioactivity can be much higher than that of the expected for this mistaken contamination since the radioisotopes attached to skin come to be close to the detectors of WBC. Finally, this makes the misjudgment of the external skin contamination as well as the excessively conservative estimation of radioactive contamination. In this study, several experiments were carried out to discriminate between the internal and external radioactive contamination using the humanoid phantom and WBC. Preliminary experimental results indicated that the use of front and backside counts could be applied to the discrimination of the external skin contamination and the difference of detected radioactivities between front and backside counts was less than about factor 2 for the internal contamination

  12. Research on internal dosimetry for some of gamma emitting nuclides for radiation workers by direct method (in-vivo) with using a chair-type whole-body counter

    International Nuclear Information System (INIS)

    Nguyen Van Hung; Pham Hung Thai

    2003-01-01

    This research objective is to establish a chair-type whole-body counter with using NaI(Ti) detector in large sizes and whole-body standard phantoms as well as to apply the computational program of LUDEP 2.0. Steel holder with a lead collimator, two whole-body standard phantoms in Vietnamese adults (one for male and another for female) by plastic material, electronic blocks of ADC and MCD (8K), MCA program for measuring gamma spectrum by VB6 language in Windows are established and made. In addition, applied research for the program of LUDEP 2.0 in order to calculate and evaluated internal doses for radiation workers is carried out. (author)

  13. Whole-Body Counter(WBC) and food radiocesium contamination surveys in Namie, Fukushima Prefecture.

    Science.gov (United States)

    Hosokawa, Yoichiro; Nomura, Kazuki; Tsushima, Eiki; Kudo, Kohsei; Noto, Yuka; Nishizawa, Yoshiko

    2017-01-01

    This study examined the internal Cs exposure of residents and the Cs present in food products produced in Namie. Whole-body counter (WBC) was used for the measurement of internal exposure per each whole body of examinees. The food products which appeared to be used for consumption, were brought by residents and commercially available food items were excluded. Most of them were wild plants or food items produced by residents. Four years of data from April 2012 to March 2013 (fiscal 2012) and April 2015 to March 2016 (Fiscal 2015) were analyzed and studied. The average radioactivity measured by WBC was approximately 5 Bq for Cs-134, and 20 Bq for Cs-137 and the average committed effective dose was approximately 1 μSv. The average for the residents with detectable radioactivity was 25 μSv, and the human health effects are considered to be extremely low risk. However, the radioactivity of the affected individuals showed a higher value than the theoretical attenuation rate. The majority (83.2%) of individuals exhibiting radioactivity were over 50 years old. The number of food products brought in for detection decreased as the study period progressed, but the number of food products with radioactivity had increased. While the items with a higher detection rate of radioactivity included fruits such as citron and persimmon, shiitake mushrooms exhibited the highest radioactivity. Moreover, the radioactivity of seven items in these 10 items decreased from fiscal 2012 to fiscal 2015. Mushrooms had high radioactivity and were produced over a wide area. We suggest that the elderly try to enjoy life and eat wild plants in moderation while inspecting food products. Therefore, we will continue to work in raising awareness of radiation and its potential presence in food products and thus the continuing necessity of monitoring radioactivity in food in the future.

  14. Whole-Body Counter(WBC and food radiocesium contamination surveys in Namie, Fukushima Prefecture.

    Directory of Open Access Journals (Sweden)

    Yoichiro Hosokawa

    Full Text Available This study examined the internal Cs exposure of residents and the Cs present in food products produced in Namie. Whole-body counter (WBC was used for the measurement of internal exposure per each whole body of examinees.The food products which appeared to be used for consumption, were brought by residents and commercially available food items were excluded. Most of them were wild plants or food items produced by residents. Four years of data from April 2012 to March 2013 (fiscal 2012 and April 2015 to March 2016 (Fiscal 2015 were analyzed and studied.The average radioactivity measured by WBC was approximately 5 Bq for Cs-134, and 20 Bq for Cs-137 and the average committed effective dose was approximately 1 μSv. The average for the residents with detectable radioactivity was 25 μSv, and the human health effects are considered to be extremely low risk. However, the radioactivity of the affected individuals showed a higher value than the theoretical attenuation rate. The majority (83.2% of individuals exhibiting radioactivity were over 50 years old. The number of food products brought in for detection decreased as the study period progressed, but the number of food products with radioactivity had increased. While the items with a higher detection rate of radioactivity included fruits such as citron and persimmon, shiitake mushrooms exhibited the highest radioactivity. Moreover, the radioactivity of seven items in these 10 items decreased from fiscal 2012 to fiscal 2015. Mushrooms had high radioactivity and were produced over a wide area.We suggest that the elderly try to enjoy life and eat wild plants in moderation while inspecting food products. Therefore, we will continue to work in raising awareness of radiation and its potential presence in food products and thus the continuing necessity of monitoring radioactivity in food in the future.

  15. Effectiveness of Different Rest Intervals Following Whole-Body Vibration on Vertical Jump Performance between College Athletes and Recreationally Trained Females

    Directory of Open Access Journals (Sweden)

    Nicole C. Dabbs

    2015-09-01

    Full Text Available The purpose of this study was to evaluate the effect of different rest intervals following whole-body vibration on counter-movement vertical jump performance. Sixteen females, eight recreationally trained and eight varsity athletes volunteered to participate in four testing visits separated by 24 h. Visit one acted as a familiarization visit where subjects were introduced to the counter-movement vertical jump and whole-body vibration protocols. Visits 2–4 contained 2 randomized conditions. Whole-body vibration was administered in four bouts of 30 s with 30 s rest between bouts. During whole-body vibration subjects performed a quarter squat every 5 s, simulating a counter-movement vertical jump. Whole-body vibration was followed by three counter-movement vertical jumps with five different rest intervals between the vibration exposure and jumping. For a control condition, subjects performed squats with no whole-body vibration. There was a significant (p < 0.05 main effect for time for vertical jump height, peak power output, and relative ground reaction forces, where a majority of individuals max jump from all whole-body vibration conditions was greater than the control condition. There were significant (p < 0.05 group differences, showing that varsity athletes had a greater vertical jump height and peak power output compared to recreationally trained females. There were no significant (p > 0.05 group differences for relative ground reaction forces. Practitioners and/or strength and conditioning coaches may utilize whole-body vibration to enhance acute counter-movement vertical jump performance after identifying individuals optimal rest time in order to maximize the potentiating effects.

  16. Whole-body counter surveys of Miharu-town school children for four consecutive years after the Fukushima NPP accident

    Science.gov (United States)

    Hayano, Ryugo S.; Tsubokura, Masaharu; Miyazaki, Makoto; Satou, Hideo; Sato, Katsumi; Masaki, Shin; Sakuma, Yu

    Comprehensive whole-body counter surveys of Miharu town school children have been conducted for four consecutive years, in 2011-2014. This represents the only long-term sampling-bias-free study of its type conducted after the Fukushima Dai-ichi accident. For the first time in 2014, a new device called the Babyscan, which has a low $^{134/137}$Cs MDA of $< 50$ Bq/body, was used to screen the children shorter than 130 cm. No child in this group was found to have detectable level of radiocesium. Using the MDAs, upper limits of daily intake of radiocesium were estimated for each child. For those screened with the Babyscan, the upper intake limits were found to be <1 Bq/day for $^{137}$Cs. Analysis of a questionnaire filled out by the children's parents regarding their food and water consumption shows that the majority of Miharu children regularly consume local and/or home-grown rice and vegetables. This however does not increase the body burden.

  17. A review of whole-body counting techniques appropriate to the study of gastrointestinal absorption

    International Nuclear Information System (INIS)

    Boddy, K.

    1976-01-01

    The wide range of whole-body counters in use for, or applicable to, the study of gastrointestinal absorption is reviewed. Shielded-room or high-sensitivity shadow-shield counters will generally be required only when there is a separate need to measure total body potassium or in studies involving pregnancy or children. For measuring gastrointestinal absorption per se, it is concluded that very simple whole-body counters of the shadow-shield or partial-shield type are usually satisfactory. These systems are of lower cost, and an economic justification for their use is derived by comparing their costs with those of hospitalizing patients for alternative investigations of gastrointestinal absorption. A resume of the general methodology is presented and some operational features and precautions are described. (author)

  18. Measurement of caesium-137 in the human body using a whole body counter

    Science.gov (United States)

    Elessawi, Elkhadra Abdulmula

    Gamma radiation in the environment is mainly due to naturally occurring radionuclides. However, there is also a contribution from anthropogenic radionuclides such as 137Cs which originate from nuclear fission processes. Since 1986, the accident at the Chernobyl power plant has been a significant source of artificial environmental radioactivity. In order to assess the radiological impact of these radionuclides, it is necessary to measure their activities in samples drawn from the environment and in plants and animals including human populations. The whole body counter (WBC) at the University Hospital of Wales in Cardiff makes in vivo measurements of gamma emitting radionuclides using a scanning ring of six large-volume thallium-doped sodium iodide (Nal(Tl)) scintillation detectors. In this work the WBC was upgraded by the addition of two high purity germanium (HPGe) detectors. The performance and suitability of the detection systems were evaluated by comparing the detection limits for Cs. Sensitivities were measured using sources of known activity in a water filled anthropomorphic phantom and theoretical minimum detectable count-rates were estimated from phantom background pulse height spectra. The theoretical minimum detectable activity was about 24 Bq for the combination of six Nal(Tl) detectors whereas for the individual HPGe detectors it was 64 Bq and 65 Bq, despite the much improved energy resolution Activities of 137Cs in the human body between 1993 and 2007 were estimated from the background Nal(Tl) spectra of 813 patients and compared with recent measurements in 14 volunteers. The body burden of Cs in Cardiff patients increased from an average of about 60 Bq in the early and mid 1990s to a maximum of about 100 Bq in 2000. By 2007 it had decreased to about 40 Bq. This latter value was similar to that of Cardiff residents at the time of the Chernobyl accident and to that of the volunteers measured in 2007 (51 Bq). However, it was less than the mean activity of

  19. Monte Carlo calculation of efficiencies of whole-body counter, by microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, J.M.

    1987-01-01

    A computer programming using the Monte Carlo method for calculation of efficiencies of whole-body counting of body radiation distribution is presented. An analytical simulator (for man e for child) incorporated with 99m Tc, 131 I and 42 K is used. (M.A.C.) [pt

  20. International whole body counter intercomparison based on BOMAB phantom simulating 4 years old child

    International Nuclear Information System (INIS)

    Battisti, P.; Tarroni, G.

    1995-11-01

    In April 1993 a whole body counter intercomparison campaign, The 1993 Intercomparison/Intercalibration, started. The campaign has been organized by The Canadian National Reference Centre for In-Vivo Monitoring of Radiation Protection Bureau, Health Canada and The United States Department of Energy and it was based on measurements on a BOMAB type phantom simulating a 4 years old child. The phantom was filled with radioactive tissue substitute resin and an unknown quantity of radioactivity. Each facility was asked to determine the identity and amount of the radionuclide(s), knowing that the specific activity in the 10 BOMAB's sections was the same. Each facility was also asked to calculate the minimum detectable activity of all the radionuclides detected in the phantom. 35 Facilities from 20 different Countries took part in the initiative. The Institute for Radiation Protection of the Environment Department of ENEA (ENEA AMB IRP) represented Italy. Intercomparison results supplied by ENEA AMB IRP as radionuclides identification, activity data and associated precision, minimum detectable activity levels, can be considered satisfactory and comparable with results supplied by similar-facilities

  1. Whole-body counter surveys of Miharu-town school children for four consecutive years after the Fukushima NPP accident

    International Nuclear Information System (INIS)

    Hayano, Ryugo S.; Tsubokura, Masaharu; Miyazaki, Makoto; Satou, Hideo; Sato, Katsumi; Masaki, Shin; Sakuma, Yu

    2015-01-01

    Comprehensive whole-body counter surveys of Miharu-town school children have been conducted for four consecutive years, in 2011-2014. This represents the only long-term sampling-bias-free study of its type conducted after the Fukushima Dai-ichi accident. For the first time in 2014, a new device called the Babyscan, which has a low "1"3"4"/"1"3"7Cs MDA of <50 Bq/body, was used to screen the children shorter than 130 cm. No child in this group was found to have detectable level of radiocesium. Using the MDAs, upper limits of daily intake of radiocesium were estimated for each child. For those screened with the Babyscan, the upper intake limits were found to be ≲1 Bq/day for "1"3"7Cs. Analysis of a questionnaire filled out by the children's parents regarding their food and water consumption shows that the majority of Miharu children regularly consume local and/or home-grown rice and vegetables. This however does not increase the body burden. (author)

  2. A whole body counter for the detection, identification and localization of incorporated radionuclides over a wide range of energies and intensities

    International Nuclear Information System (INIS)

    Bader, R.; Lorenz, W.J.

    1977-01-01

    A shadow-shielded whole body counter has been designed and installed at the German Cancer Research Centre. It is equipped with special focussing collimators, four detectors and a supplementary Ge(Li) detector, and is used for the detection, identification and localization of incorporated radionuclides over a range of intensities from a few nCi to several mCi and a range of gamma energies from 100 keV to several MeV. The system has been tested since 1976 in medical research and diagnosis and for staff monitoring. (orig.) [de

  3. Experience with a mobile whole body counting screening program at Ontario Hydro

    International Nuclear Information System (INIS)

    Wong, K.Y.

    1976-01-01

    A whole-body counting program using a trailer-mounted counter has been in service in Ontario Hydro since 1972 to monitor routinely internal uptakes of radionuclides by nuclear station employees. The philosophy and objectives of the program are discussed; equipment and calibration procedures are described, and experience over the past two and a half years is reviewed. The procedures to minimize the effects of external contamination, a problem commonly encountered in whole-body counting, are described. (auth)

  4. Counter of radiation in body parts

    International Nuclear Information System (INIS)

    Pollard, D.E.

    1983-01-01

    A new radiation counter for the determination of radiocontaminated body parts has been designed. Composed of several movable detectors, shielded from background radiation and focused on different parts of the human body by narrow apertures in the lead enclosure, the invention provides a quick tool for quantitative and qualitative part-by-part analysis of the body with respect to radiocontamination. The counter can be handled easily by the tested person himself and consequently, it is suitable for mass controls etc. (G.J.P.)

  5. High-resolution gamma spectroscopy with whole-body and partial-body counters. Experience, recommendations. Report; Hochaufloesende Gamma-Spektrometrie an Ganz- und Teilkoerperzaehlern. Erfahrungen, Empfehlungen. Bericht

    Energy Technology Data Exchange (ETDEWEB)

    Sahre, P. [comp.

    1997-12-01

    The application of high-resolution gamma spectroscopy with whole-body and partial-body counters shows a steadily rising upward trend over the last few years. This induced the ``Arbeitskreis Inkorporationsueberwachung`` of the association ``Fachverband fuer Strahlenschutz e.V.`` to organise a meeting for joint elaboration of a guide on recommended applications of this measuring technique, based on a review of existing experience and results. A key item on the agenda of the meeting was the comparative evaluation of the Ge semiconductor detector and the NaI solid scintillation detector. (orig./CB) [Deutsch] Der Einsatz der hochaufloesenden Gammaspektroskopie in Ganz- und Teilkoerperzaehlern hat in den letzten Jahren stetig zugenommen. Der ``Arbeitskreis Inkorporationsueberwachung`` des Fachverbandes fuer Strahlenschutz e.V. hat darum bisherige Erfahrungen zusammengetragen und Empfehlungen fuer den Einsatz dieser Messtechnik erarbeitet. Der Schwerpunkt der Tagung lag beim Vergleich von Germaniumhalbleiter- mit Natriumjodid-Festszintillationsdetektoren.Tl-Detektoren eignen sich v.a. beim Vorhandensein bekannter und zeitlich konstanter Nuklidvektoren (Kernkraftwerke, Nuklearmedizin). Bei unbekanntem bzw. variablem Nuklidvektor (Stoerfall, Unfall, Forschung) sollen Ge-Detektoren benutzt werden (orig./ABI)

  6. Quantitative determination of blood losses by a whole-body counter

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Garreta, A.C. de; Soria, N.; Blanco, E.

    1976-01-01

    A method to quantitate blood losses by determination of the 51 Cr whole body retention (WBR) was developed. Autologous red cells labelled with Na 2 O 4 51 Cr were given intravenously. Blood losses were simulated by withdrawing blood samples. Percent relative variation (PRV) between real blood losses (blood withdrawal) and blood losses calculated by determining the WBR, were found. Withdrawal of 60 ml blood gave a PRV lower than 10.0%. 51 Cr body loss due to elution and red cell death was found to be 0.017 day -1 . The method allows the accurate detection of total blood losses of 60 ml or more, and it can be used to quantitate gastrointestinal or gynecological hemorrhages, avoiding the inconveniences involved by the complete recolection of faeces or of towels and tampons. (author) [es

  7. Monte Carlo simulation of a stand-up type whole body counter using different sized BOMAB phantoms

    International Nuclear Information System (INIS)

    Park, Minjung; Yoo, Jaeryong; Park, Seyoung; Ha, Wiho; Lee, Seungsook; Park, Minjung; Yoo, Jaeryong; Kim, Kwangpyo

    2013-01-01

    It is necessary to assess internal contamination level to determine the need for medical intervention. Whole Body Counter (WBC) is used to measure incorporated radioactive materials inside the human body. Also, WBC is standard in vivo method and used for preparedness of response to radiological emergencies. To operate this equipment correctly, proper energy and efficiency calibrations must be performed. WBC is usually calibrated using a Bottle Manikin ABsorber (BOMAB) Phantom, which is the industrial standard. The problem occurs when the subjects to be measured have different physical characteristics (height or weight) from a phantom used in calibration. In radiation emergency situations, this problem is expected to worsen because there are special populations whose physical characteristics are different from reference male, for example children and women. The aim of this study is to resolve this problem by simulating counting efficiency of different sized BOMAB phantoms using Monte Carlo techniques. The counting efficiency response of the WBC has been modeled for different sized four BOMAB phantoms using MCNPX. The stand-up type WBC has different efficiency response on phantom size since this WBC has different geometry from other scanning-type or non-linear geometry WBC. In emergency monitoring situations, it is important to estimate activity of various sized persons. Therefore, it is necessary to apply appropriate counting efficiency according to person size. Further investigations are needed to optimize methodology for measuring small object in the stand-up type WBC

  8. Proposal of a methodology to evaluate occupational internal exposure to Fluorine-18

    International Nuclear Information System (INIS)

    Oliveira, C.M.; Dantas, A.L.A.; Dantas, B.M.

    2008-01-01

    The increasing use of 18 F for diagnostic procedures in nuclear medicine through PET technology leads to the growth in the number of occupationally exposed workers to this radionuclide. The external and internal exposures may occur both in the production of the radiopharmaceutical fluorodeoxyglucose ( 18 FDG) and during its clinical use in nuclear medicine departments. Workers involved in such activities are usually monitored routinely for the control of external exposure. However it is important provide methods for internal monitoring promptly after a suspicion of incorporation. Therefore, the objective of this work is to develop procedures for internal monitoring of 18 F to be applied in cases of possible incorporation of fluoride and 18 FDG, using in vivo and in vitro methods of measurements. The NaI(Tl) 8x4 scintillation detector of the IRD-Whole Body Counter was calibrated for in vivo measurements with a whole body anthropomorphic phantom, simulating homogeneous distribution of 18 F in the body. The NaI(Tl) 3x3 scintillation detector of the IRD-Whole Body Counter was calibrated for in vivo measurements with a brain phantom inserted in an artificial skull, simulating 18 FDG incorporation. The HPGe detection system of the IRD-Bioassay Laboratory was calibrated for in vitro measurements of urine samples with 1 liter plastic bottles containing standard liquid source. A methodology for bioassay data interpretation, based on standard ICRP models edited with the software AIDE-version 6, was established. It is concluded that in vivo measurements have sufficient sensitivity for the monitoring of 18 F in the forms of fluoride and 18 FDG. The use of both in vitro and in vivo bioassay data can provide useful information for the interpretation of bioassay data in cases of accidental incorporation in order to identify the most likely route of intake, chemical form of 18 F incorporated and time of intake. (author)

  9. Whole body counter calibration using Monte Carlo modeling with an array of phantom sizes based on national anthropometric reference data

    International Nuclear Information System (INIS)

    Shypailo, R J; Ellis, K J

    2011-01-01

    During construction of the whole body counter (WBC) at the Children's Nutrition Research Center (CNRC), efficiency calibration was needed to translate acquired counts of 40 K to actual grams of potassium for measurement of total body potassium (TBK) in a diverse subject population. The MCNP Monte Carlo n-particle simulation program was used to describe the WBC (54 detectors plus shielding), test individual detector counting response, and create a series of virtual anthropomorphic phantoms based on national reference anthropometric data. Each phantom included an outer layer of adipose tissue and an inner core of lean tissue. Phantoms were designed for both genders representing ages 3.5 to 18.5 years with body sizes from the 5th to the 95th percentile based on body weight. In addition, a spherical surface source surrounding the WBC was modeled in order to measure the effects of subject mass on room background interference. Individual detector measurements showed good agreement with the MCNP model. The background source model came close to agreement with empirical measurements, but showed a trend deviating from unity with increasing subject size. Results from the MCNP simulation of the CNRC WBC agreed well with empirical measurements using BOMAB phantoms. Individual detector efficiency corrections were used to improve the accuracy of the model. Nonlinear multiple regression efficiency calibration equations were derived for each gender. Room background correction is critical in improving the accuracy of the WBC calibration.

  10. Determination of calibration factors for whole body counting of members of public

    International Nuclear Information System (INIS)

    Vijayagopal, P.; Joyeeta, M.; Garg, S.P.; Vidhani, J.M.; Pendharkar, K.A.

    2005-01-01

    A Mobile Radiological Laboratory (MRL) was recently developed by Internal Dosimetry Division in BARC. In the event of an accident involving release of radioactive substances into the environment, there will be a need to measure both the external and the internal exposure of the population. MRL has been equipped with a variety of radiation detectors, radiation survey meters and a whole body monitor for this purpose. For whole body monitoring of members of public, detector systems are required to be calibrated with the age dependent phantoms of appropriate size for both male and female subjects. In this paper we present the results of the calibration studies carried out with shielded chair whole body counter of MRL using five different age dependent male phantoms representing the age groups of 1,5,10 and 15 year old children and 20 year old adult. Calibration work has been carried out using standard sources of 137 Cs, 133 Ba and 60 Co. (author)

  11. Monte Carlo simulation of lung counting efficiency using a whole-body counter at a nuclear power plant

    International Nuclear Information System (INIS)

    Dongming, L.; Shuhai, J.; Houwen, L.

    2016-01-01

    In order to routinely evaluate workers' internal exposure due to intake of radionuclides, a whole-body counter (WBC) at the Third Qinshan Nuclear Power Co. Ltd. (TQNPC) is used. Counting would typically occur immediately after a confirmed or suspected inhalation exposure. The counting geometry would differ as a result of the height of the individual being counted, which would result in over- or underestimated intake(s). In this study, Monte Carlo simulation was applied to evaluate the counting efficiency when performing a lung count using the WBC at the TQNPC. In order to validate the simulated efficiencies for lung counting, the WBC was benchmarked for various lung positions using a 137 Cs source. The results show that the simulated efficiencies are fairly consistent with the measured ones for 137 Cs, with a relative error of 0.289%. For a lung organ simulation, the discrepancy between the calibration phantom and the Chinese reference adult person (170 cm) was within 6% for peak energies ranging from 59.5 keV to 2000 keV. The relative errors vary from 4.63% to 8.41% depending on the person's height and photon energy. Therefore, the simulation technique is effective and practical for lung counting, which is difficult to calibrate using a physical phantom. (authors)

  12. An unshielded whole body radioactivity counter for monitoring persons after a radiation accident

    International Nuclear Information System (INIS)

    Katoch, D.S.; Somasundaram, S.

    1979-01-01

    An unshielded chair in which the subject sits, holding a 7.6 cm x 7.6 cm NaI (Tl) detector in his lap, was evaluated for monitoring of persons suspected of internal radioactive contamination following a radiation accident. The reduction in different energy bands of the background gamma-ray spectrum due to self-shielding of the subject was studied for two postures, designated ''upright'' and ''folding'' and the data were analysed in a CDC 3600 computer to obtain the best-fit regression equation relating the reduction factor with body weight and height. The response of the counter was evaluated using an in vitro method and the ranges of under/over-estimation of body burden resulting from assumption of partial/uniform distribution of activity were determined. Counting sensitivities were derived for 13 radioisotopes having gamma-ray energies in the range 145 keV-1.46 MeV. The results are presented and discussed. The study shows that this simple system may be used not only in radiation emergencies but also for operational monitoring of radiation workers for a number of radioisotopes of low and medium radiotoxicity. (auth.)

  13. Practical methods for the functioning evaluation of the whole body counter system Accuscan II of the ININ; Metodos practicos para la evaluacion del comportamiento del sistema contador de cuerpo entero Accuscan II del ININ

    Energy Technology Data Exchange (ETDEWEB)

    Alfaro L, M. M.; Ramirez J, F. J.; Mondragon C, L., E-mail: mercedes.alfaro@inin.gob.mx [ININ, Carretera Mexico-Touca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    The whole body counter system Accuscan II of the Instituto Nacional de Investigaciones Nucleares (ININ), was designed and built to quantify and to measure radionuclides fission product as well as gamma emitters, with a maximum sensibility of less than 10 n Ci for cobalt 60 at one time of counting of 5 minutes. The system has two detectors of Ge(Hp) with Beryllium window to a relative efficiency of 25% in a counting configuration of vertical scanning, this configuration gives a plane response of constant efficiency. In this work some practical methods developed in the Internal Dosimetry Laboratory to carry out the functioning evaluation of the whole body counter system Accuscan II of the ININ are described. With the obtained results of this evaluation we can decide fine adjustments will be necessary for the optimization of the equipment operation. The evaluation of this equipment was especially necessary, due to its 21 years-old antiquity and for the gradual changes that has in its functioning. The equipment is intrinsically a gamma spectrometry system and some described experiences could be applied too in other gamma spectrometry systems. (Author)

  14. Determination of iron absorption and excretion by whole-body counting

    International Nuclear Information System (INIS)

    Hollard, D.; Benabid, Y.; Berard, M.; Bonnin, J.; Darnault, J.; Millet, M.

    1969-01-01

    Using a whole-body counter, the authors have studied 59 Fe absorption and loss in 8 normal subjects and in 30 iron deficient patients. Results showed that whole-body counting provided an excellent and simple method for iron retention measurements, obviating many inaccuracies of previous technic. Normal absorption of radio iron with this procedure has ranged from 9 per cent to 20 per cent of the administered tracer in normal subjects, with a mean of 15 per cent. A significant increase in 59 Fe absorption was noted in 21 iron-deficient patients in whom the retention ranged from 40 to 100 per cent. However, 3 iron-deficient patients were found to have low absorption, and their severe iron deficiency could be correlated with this defect in absorption. This method permits also the determination of the rate of iron excretion during the following months and therefore the study of the mechanism of some pathological loss. (authors) [fr

  15. Whole body MR-PET: a new internal dosimetry method for radiation transport calculation from biokinetic model data

    International Nuclear Information System (INIS)

    Nunes, Ana; Alves, Francisco; Patrício, Miguel

    2014-01-01

    In order to ensure the safe usage of new radiopharmaceuticals in Positron Emission Tomography (PET), it is necessary to quantify the doses delivered to the organs and tissues within the patients’ bodies. A framework that allows estimating the dose delivered by PET has been established by the MIRD Committee [1, 2] and ICRP []. Although this covers the most important terms and concepts in Internal Radiation Dosimetry (IRD), it does not provide a detailed guide to assist in the development of a full dosimetric study. We discuss the development, implementation, assessment and validation of an accurate method for IRD studies of PET radiotracers.

  16. Calibration of the Accuscan II In Vivo System for Whole Body Counting

    Energy Technology Data Exchange (ETDEWEB)

    Orval R. Perry; David L. Georgeson

    2011-08-01

    This report describes the April 2011 calibration of the Accuscan II HpGe In Vivo system for whole body counting. The source used for the calibration was a NIST traceable BOMAB manufactured by DOE as INL2006 BOMAB containing Eu-154, Eu-155, Eu-152, Sb-125 and Y-88 with energies from 27 keV to 1836 keV with a reference date of 11/29/2006. The actual usable energy range was 86.5 keV to 1597 keV on 4/21/2011. The BOMAB was constructed inside the Accuscan II counting 'tub' in the order of legs, thighs, abdomen, thorax/arms, neck, and head. Each piece was taped to the backwall of the counter. The arms were taped to the thorax. The phantom was constructed between the v-ridges on the backwall of the Accuscan II counter. The energy and efficiency calibrations were performed using the INL2006 BOMAB. The calibrations were performed with the detectors in the scanning mode. This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for whole body counting and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  17. Distribution of /sup 63/Ni in mice by means of whole body autoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Saito, T [Nihon Univ., Tokyo. School of Dentistry

    1974-11-01

    The uptake of Ni which was known to be contained in the dental alloy to the mammalian tissue was studied. /sup 63/Ni was injected intravenously to mice, and its distribution in their body was observed by counting radioactivity using whole body autoradiography and liquid scintillation counter from 30 minutes after the injection to 3 weeks later. Whole body autography revealed high uptake in the kidney, lung, incisor, intervertebral disc, epidermis cuticle, hair follicle, and liver during 30 minutes later to 8 hours period, and in the lung, renal cortex, central nerve, epidermis cuticle, and hair follicle during 2 days to 3 weeks period. /sup 63/Ni taken up in the tissue or organs rapidly disappeared by 8 hours period, and the rank of high uptake tissues slightly changed during 30 minutes later to 8 hours period. /sup 63/Ni administered in the body was considered to be excreted through the kidney, however, /sup 63/Ni taken up in the central nerve showed remarkably delayed excretion.

  18. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  19. An experimental test on large animals of MCNP application for whole body counting

    International Nuclear Information System (INIS)

    Borisov, N.; Yatsenko, V.; Kochetkov, O.; Gusev, I.; Vlasov, P.; Kalistratova, V.; Nisimov, P.; Levochkin, F.; Borovkov, M.; Stolyarov, V.; Tsedish, S.; Tyurin, I.; Franck, D.; Carlan, L. de

    2005-01-01

    Measurements of actinide body burden using whole body counting spectrometry is hampered due to intensive absorption of γ-rays inside the patient's body, which depends on the anatomy of a patient. To establish the correspondence between pulse-height-spectra intensity and radionuclide activity, Monte Carlo calculations are widely used. For such calculations, the radiation transport geometry is usually described in terms of small rectangular boxes (voxels) retrieved from computed tomography or magnetic resonance images. The software for Monte Carlo-assisted calibration of whole body counting, which performs automatic creation of individual MCNP voxel phantoms, was checked in a quasi-in vivo experiment on large animals. During the experiment, pigs of 35-40 kg body mass were used as phantoms for measurement of actinides body burden. 241 Am was administered (via injection of a radioactive solution or via implantation of plastic capsules containing the radioactive material) into the lungs of pigs. The pigs were measured using the pure germanium low-energy γ-spectrometers. The images of animals were obtained using the computed tomography machine. On the base of these tomograms, MCNP4c2 calculations were done to obtain the pulse-height-spectra of the whole body counters. The experimental results were reproduced in calculations with error of less than 30% for 241 Am administered via injection and less than 10% for 241 Am administered inside the capsules. (authors)

  20. "Ird, K." sai Riias preemia

    Index Scriptorium Estoniae

    2011-01-01

    7. Balti teatrifestivalil Riias sai Tartu Uue Teatri juht Ivar Põllu auhinna lavastuse "Ird, K." kontseptsiooni ja helikujunduse eest ning näitleja Nero Urke Kaarel Irdi rolli eest. Von Krahli Teatri truppi hinnati aja ja ruumi loova käsitluse eest lavastuses "The End"

  1. Whole-body MRI screening

    Energy Technology Data Exchange (ETDEWEB)

    Puls, Ralf [HELIOS Klinikum Erfurt (Germany). Inst. of Diagnostic and Interventional Radiology and Neuroradiology; Hosten, Norbert (ed.) [Universitaetsklinikum Greifswald (Germany). Diagnostic Radiology and Neuroradiology

    2014-07-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  2. Whole-body MRI screening

    International Nuclear Information System (INIS)

    Puls, Ralf; Hosten, Norbert

    2014-01-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  3. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  4. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  5. Whole body measurements in Bavarian school children

    International Nuclear Information System (INIS)

    Schmier, H.; Berg, D.

    1992-12-01

    On behalf of the Bavarian State Ministry for State Development and Environmental Affairs measurements were conducted using the whole body counters at the Institute for Radiation Hygiene (of the Federal Office for Radiation Protection), and the Institute for Radiation Biology (of the GSF Research Centre for Environment and Health). Between September 1988 and July 1990 about 1600 school children from all over Bavaria were investigated for incorporated radiocesium. The aim of these measurements was to evaluate the whole body activity due to regionally differing soil contaminations in Bavaria following the accident in the nuclear power plant in Chernobyl and to assess the effective dose from an intake of radionuclides for the pupils by comparing the results of their WBC measurements with those of reference groups of children which underwent WBC examinations at regular intervals at both institutes since the middle of the year 1986. The results of the WBC measurements of those pupils who had not eaten mushrooms in the days before the measurement are in good agreement with the results of comparative measurements in children living in the regions of Munich and Frankfurt-am-Main. Based on these results an effective dose of 0,2 mSv for the Munich region children and of 0,1 mSv for Nothern Bavarian children can be derived. For children living in the highest contaminated region of Bavaria, i.e. the counties adjacent to the Alps, no comparable reference group results are available, but the amount of incorporated radiocesium is only twice that for pupils in the Munich region. The mean value for the specific activity of radiocesium in South Bavarian school children who consumed mushrooms was found to be twice the value of pupils who did not. This is also true for that group of children whose parents had bought allegedly low contaminated foodstuffs. Other effecs of nutrition habits on the specific whole body activity could not be found. (orig.) [de

  6. 24-hour whole-body retention of sup(99m)Tc-diphosphonate

    International Nuclear Information System (INIS)

    Kapitola, J.

    1985-01-01

    A new method is described for the examination of bone tissue metabolism; a 24-hour retention of diphosphonate labelled with radioactive sup(99m)Tc (assessed using a whole-body counter or by estimation of the amount of labelled substance excreted in the course of 24 hours via the urine). The values are elevated in primary hyperparathyroidism, osteomalacia, generalized Paget's disease, multiple bone metastases; the values are not uniform in osteoporosis. The method is simple, sensitive and reliable (provided renal function is normal), suited for screening, as part of specialized osteological diagnosis as well as for repeated longitudinal investigations. (author)

  7. The ACCUSCAN-II vertical scanning germanium whole body counter

    International Nuclear Information System (INIS)

    Bronson, F.L.

    1987-01-01

    The ACCUSCAN-II is manufactured by Canberra Industries, and represents a new generation of WBC systems. One or two Germanium detectors are used for precise nuclide identification. The detectors scan the total body and can accurately quantify radioactive material anywhere in the body. The shield is a full 4'' thick steel or 2'' lead and weighs about 9000 lbs. The subject can be counted standing for full body scans, or seated for longer counting times of limited portions of the body. Optional electronics also generate a count rate vs. body position profile, as an aid to interpretation of the dose implications of the count. Typical LLD's are 5 - 10 nCi for a 5 minute total body count and 0.5 - 0.7 nCi for a 5 minute long screening count. The system is available in several flavors. The manual version is an inexpensive system intended for universities, hospitals and small industrial facilities. The automatic system includes a MicroVAX-II computer and runs ABACOS0-II Body Burden Software, and is ideal for facilities with large numbers of people to count and where automated analysis of the data is desirable

  8. Monitoring of the general population with an installed whole body counter at West Cumberland Hospital, Whitehaven

    International Nuclear Information System (INIS)

    Boddy, K.; Francis, R.A.; Fenwick, J.D.; McKenzie, A.L.

    1989-03-01

    Body radioactivity in the general public has been measured in 395 volunteers in the Whitehaven area, using a whole-body monitor at West Cumberland Hospital. Between October 1986 and October 1987, estimates of total body radiocaesium in 240 volunteers ranged from below detection level to 1844 Bq with a mean of 415 Bq. From October 1987 until May 1988, a further 155 volunteers were monitored, and radiation levels ranged from 34 Bq to 685 Bq, with a mean of 257 Bq. In all volunteers, the ratio of body radiocaesium to body potassium, was well below unity. The average ratio of caesium-137 to caesium-134 from October 1987 to May 1988 was 3.28, corresponding to a ratio of 1.99 at the date of Chernobyl accident. This is consistent with a Chernobyl origin as the primary source for the radiocaesium. There were discernible, but not marked, trends of increasing body radiocaesium with milk and meat/fish consumption. (author)

  9. Measuring radioactivity in the body

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-09-15

    Techniques of measuring the total amount of radioactivity in the body of a living person as well as the principal applications of such measurements were reviewed at a Symposium on Whole Body Counting held in Vienna from 12 to 16 June 1961. The whole body counters can be divided into two broad groups: (a) counters for the radiation protection surveillance of the general public and radiation workers, capable of detecting extremely low levels of radioactivity in the human body, and (b) counters for medical research and diagnosis, designed to check the retention and excretion of radioactive substances administered to patients for metabolic and pathological studies. In both cases, the primary requirement is that the counter must be able to measure the total activity in the body. In recent years, there has been a remarkable development of the instruments and techniques for such measurements. One of the main purposes of the symposium in Vienna was to discuss how best to use these highly sophisticated instruments.

  10. Type test of the Rados MTS-N thermoluminescent dosimetry system for individual monitoring of whole body photons in HP (10)

    International Nuclear Information System (INIS)

    Ferreira, M.S.; Silva, E.R. da; Maurício, C.L.P.

    2017-01-01

    The Institute of Radioprotection and Dosimetry (IRD/CNEN-RJ), uses an automatic thermoluminescent dosimetry (TL) system for evaluation of whole body for photons with individual monitors RADOS MTS-N, with TLF detector of LiF: Mg, Ti. The objective of this work was to characterize this system for the evaluation of H P (10) operating magnitude. The measuring range is 0.2 mSv to 2 Sv, for photon energies from 20 keV to 1250 keV. Performance tests were done for the following characteristics: homogeneity of the monitors, system reproducibility, linearity, temperature and humidity effect, energy and angular dependence and fading. The acceptance requirements used to test system performance have been drawn from national and international documents. The results obtained prove that the system can be used to measure the occupational dose of photons in H P (10)

  11. The evolution of whole-body imaging.

    LENUS (Irish Health Repository)

    Moran, Deirdre E

    2012-02-01

    This article reviews the evolution of whole-body imaging, discussing the history and development of radiography, nuclear medicine, computed tomography (CT), positron emission tomography (PET), combined PET-CT, and magnetic resonance imaging. The obstacles hindering progress toward whole-body imaging using each of these modalities, and the technical advances that were developed to overcome them, are reviewed. The effectiveness and the limitations of whole-body imaging with each of these techniques are also briefly discussed.

  12. Global analysis of gene expression in the developing brain of Gtf2ird1 knockout mice.

    Directory of Open Access Journals (Sweden)

    Jennifer O'Leary

    Full Text Available Williams-Beuren Syndrome (WBS is a neurodevelopmental disorder caused by a hemizygous deletion of a 1.5 Mb region on chromosome 7q11.23 encompassing 26 genes. One of these genes, GTF2IRD1, codes for a putative transcription factor that is expressed throughout the brain during development. Genotype-phenotype studies in patients with atypical deletions of 7q11.23 implicate this gene in the neurological features of WBS, and Gtf2ird1 knockout mice show reduced innate fear and increased sociability, consistent with features of WBS. Multiple studies have identified in vitro target genes of GTF2IRD1, but we sought to identify in vivo targets in the mouse brain.We performed the first in vivo microarray screen for transcriptional targets of Gtf2ird1 in brain tissue from Gtf2ird1 knockout and wildtype mice at embryonic day 15.5 and at birth. Changes in gene expression in the mutant mice were moderate (0.5 to 2.5 fold and of candidate genes with altered expression verified using real-time PCR, most were located on chromosome 5, within 10 Mb of Gtf2ird1. siRNA knock-down of Gtf2ird1 in two mouse neuronal cell lines failed to identify changes in expression of any of the genes identified from the microarray and subsequent analysis showed that differences in expression of genes on chromosome 5 were the result of retention of that chromosome region from the targeted embryonic stem cell line, and so were dependent upon strain rather than Gtf2ird1 genotype. In addition, specific analysis of genes previously identified as direct in vitro targets of GTF2IRD1 failed to show altered expression.We have been unable to identify any in vivo neuronal targets of GTF2IRD1 through genome-wide expression analysis, despite widespread and robust expression of this protein in the developing rodent brain.

  13. Whole-body counter surveys of over 2700 babies and small children in and around Fukushima Prefecture 33 to 49 months after the Fukushima Daiichi NPP accident

    International Nuclear Information System (INIS)

    Hayano, Ryugo S.; Tsubokura, Masaharu; Miyazaki, Makoto

    2015-01-01

    BABYSCAN, a whole-body counter (WBC) for small children was developed in 2013, and units have been installed at three hospitals in Fukushima Prefecture. Between December, 2013 and March, 2015, 2707 children between the ages of 0 and 11 have been scanned, and none had detectable levels of radioactive cesium. The minimum detectable activities (MDAs) for "1"3"7Cs were ≤3.5 Bq kg"-"1 for ages 0-1, decreasing to ≤2 Bq kg"-"1 for ages 10-11. Including the "1"3"4Cs contribution, these translate to a maximum committed effective dose of ∼16 μSv y"-"1 even for newborn babies, and therefore the internal exposure risks can be considered negligibly small. Analysis of the questionnaire filled out by the parents of the scanned children regarding their families' food and water consumption revealed that the majority of children residing in the town of Miharu regularly consume local or home-grown rice and vegetables, while in Minamisoma, a majority avoid tap water and produce from Fukushima. The data show, however, no correlation between consumption of locally produced food and water and the children's body burdens. (author)

  14. Whole-body retention studies of /sup 169/Yb-citrate. Estimation of radiation dose to humans from /sup 169/Yb-citrate

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A; Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine; Mori, H; Ando, I; Hisada, K

    1977-09-01

    For purpose of the estimation of the radiation dose to humans from /sup 169/Yb-citrate, the whole-body retention studies using five rats were carried out. Following intravenous administration of /sup 169/Yb-citrate, the whole-body activity was monitored for 40 days by the animal counter. The whole-body retention curve consisted of three components: the first with a 3.6 hours effective half-time, the second with an 154 hours effective half-time and the third with a 29.9 days effective half-time. Therefore it was assumed that 32% of the administered /sup 169/Yb-citrate clears from the kidney with a short biologic half-time (3.6 hours), 18% remains in the liver and other soft tissues with a relatively long biologic half-time (194 hours) and 50% remains in the bone with a long biologic half-time (850 days). Based on these biological data and the MIRD Committee method, the average dose to the bone and whole-body were 20.8 rads/mCi and 4.5 rads/mCi respectively.

  15. Whole-body retention studies of /sup 167/Tm--citrate. Estimation of radiation dose to humans from /sup 167/Tm--citrate

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, T; Ando, A [Kanazawa Univ. (Japan). School of Paramedicine; Mori, H; Ando, I; Sakamoto, K

    1978-02-01

    For the purpose of calculating absorbed dose to humans from /sup 167/Tm-citrate, the whole-body retention studies using 5 rats were carried out. Up to 40 days following intravenous injection of /sup 167/Tm-citrate, the whole-body counts were monitored with an animal counter. The whole-body retention curve was obtained with three exponential components. Namely, the 26% of the injected /sup 167/Tm-citrate had a biological half-time of 3.4 hours, 12.5% had a biological half-time of 99 hours and 61.5% had a biological half-time of 106 days. These results indicate, that three components consist of the rapid clearance from the kidneys, the retention in the liver and other soft tissues with relatively long half-time and the retention in the bones with long half-time. Based on these biological data and the MIRD Committee method, the average dose estimates to the bone and whole-body from intravenous administration of 1 mCi /sup 167/Tm-citrate were 7.08 rads and 1.28 rads, respectively.

  16. Comparison of whole-body-imaging methods

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hoffer, P.

    1977-01-01

    Currently there are four different devices that have found clinical utility in whole-body imaging. These are the rectilinear scanner, the multicrystal whole-body scanner, the Anger-type camera with a whole-body-imaging table, and the tomoscanner. In this text, the basic theory of operation and a discussion of the advantages and disadvantages in whole-body imaging is presented for each device. When applicable, a comparative assessment of the various devices is also presented. As with all else in life, there is no simple answer to the question ''which total body imaging device is best.'' Institutions with a very heavy total-body-imaging load may prefer to use an already available dual-headed rectilinear scanner system for these studies, rather than invest in a new instrument. Institutions with moderate total-body-imaging loads may wish to invest in moving table or moving camera devices which make total body imaging more convenient but retain the basic flexibility of the camera. The large-field Anger camera with or without motion offers another flexible option to these institutions. The laboratory with a very heavy total body imaging load may select efficiency over flexibility, thereby freeing up other instruments for additional studies. Finally, reliability as well as availability and quality of local service must be considered. After all, design features of an instrument become irrelevant when it is broken down and awaiting repair

  17. Measurement of whole body cellular and collagen nitrogen, potassium, and other elements by neutron activation and whole body counting

    International Nuclear Information System (INIS)

    James, H.M.; Fabricius, P.J.; Dykes, P.W.

    1987-01-01

    Whole body nitrogen can be measured by neutron activation analysis with an acceptable radiation dose; it is an index of body protein which, in normal subjects, is 65% cellular protein and 35% extracellular connective collagen. Whole body potassium can be measured by whole body counting without irradiating the subject; it is an index of body cell mass. We measured whole body nitrogen, potassium, extracellular water, intracellular water, and fat-folds. The differences between 37 malnourished patients and five normal subjects suggested that the patients had 9 kg less cell mass than normal, but no difference in extracellular mass. Measurements were made on eight patients before and after 14 days of total parenteral nutrition; balance of nitrogen intake and excretion also was measured. The changes were consistent with mean increases of 3 kg of cellular mass and 3 kg of fat with no change of extracellular mass. The accuracy and sensitivity of the whole body measurements need further confirmation for use in patients with changing body composition. Where tissue wasting is largely from the cellular compartment, potassium could be a more sensitive index of wasting than nitrogen. Multielement analysis of nitrogen, potassium, chlorine, and carbon will probably be valuable in elucidating body composition in malnutrition

  18. Whole-body profile scanner for in vivo quantitative activity measurement

    International Nuclear Information System (INIS)

    Bergmann, H.

    1978-01-01

    A whole-body profile scanner has been developed by fitting parallel slit collimators to a shadow shield whole-body counter. Sensitivity, uniformity and resolution measurements were performed using a number of different counting conditions. It is shown that improved accuracy of activity measurements is obtained by using a wide window counting technique for low and medium energy gamma emitters (99m Tc, 131 I), whereas a photopeak window should be used for high energy gamma emitters (47 Ca). Due to the finite spatial resolution of the system a systematic error in evaluating regional activities from the counting rate profile occurs which is characterized by a spatial spillover factor. The spatial spillover factor is measured and is subsequently used to calculate the error on basis of a simple model. It is shown that only small errors are caused by spatial spillover when the length of a region is at least three times the full width half maximum of the point spread function. Applying the above mentioned simple rules it is concluded that profile scanning is a sensitive and accurate technique for activity measurements in vivo. Two examples of clinical applications (measurement of bone accretion rates of calcium and Tc-pyrophosphate, regional radioiodine retention in patients with thyroid carcinoma) and a review of the papers on profile scanning demonstrate the types of investigations in which profile scanning is superior to alternative techniques. (author)

  19. IRD dropout study

    Science.gov (United States)

    Yalowitz, Jeffrey S.; Schroer, Michael A.; Dickson, John E., Jr.

    1992-01-01

    This final report describes work performed by SRS Technologies for the NASA Marshall Space Flight Center under Contract NAS8-39077, entitled 'Integrated Receiver-Decoder Dropout Study'. The purpose of the study was to determine causes of signal fading effects on ultra-high-frequency (UHF) range safety transmissions to the Space Shuttle during flyout. Of particular interest were deep fades observed at the External Tank (ET) Integrated Receiver-Decoder (IRD) during the flyout interval between solid rocket booster separation and ET separation. Analytical and simulation methods were employed in this study to assess observations captured in flight telemetry data records. Conclusions based on the study are presented in this report, and recommendations are given for future experimental validation of the results.

  20. 3D whole body scanners revisited

    NARCIS (Netherlands)

    Daanen, H.A.M.; Haar, F.B. ter

    2013-01-01

    An overview of whole body scanners in 1998 (H.A.M. Daanen, G.J. Van De Water. Whole body scanners, Displays 19 (1998) 111-120) shortly after they emerged to the market revealed that the systems were bulky, slow, expensive and low in resolution. This update shows that new developments in sensing and

  1. Development of intellectual reactor design system IRDS

    International Nuclear Information System (INIS)

    Kugo, T.; Tsuchihashi, K.; Nakagawa, M.; Mori, T.

    1993-01-01

    An intellectual reactor design system IRDS has been developed to support feasibility study and conceptual design of new type reactors in the fields of reactor core design including neutronics, thermal-hydraulics and fuel design. IRDS is an integrated software system in which a variety of computer codes in the different fields are installed. An integration of simulation modules are performed by the information transfer between modules through design model in which the design information of the current design work is stored. An object oriented architecture is realized in frame representation of core configuration in a design data base. The knowledge relating to design tasks to be performed are encapsulated, to support the conceptual design work. The system is constructed on an engineering workstation, and supports efficiently design work through man-machine interface adopting the advanced information processing technologies. Optimization methods for design parameters with use of the artificial intelligence technique are now under study, to reduce the parametric study work. A function to search design window in which design is feasible is realized in the fuel pin design. (orig.)

  2. USE OF WHOLE-BODY VIBRATION AS A MODE OF WARMING UP BEFORE COUNTER MOVEMENT JUMP

    Directory of Open Access Journals (Sweden)

    Enrique G. Artero

    2007-12-01

    Full Text Available Whole-body vibration (WBV has been suggested to be particularly effective on the stretch-shortening cycle-based movements, such as the counter movement jump (CMJ test (Issurin, 2005. Nevertheless, the literature on short-term vibration exposure and lower limb explosive performance (measured by CMJ test is contradictory. Either transient improvements (Bosco et al., 2000; Cochrane and Stannard, 2005; Torvinen et al., 2002a or no effects (Torvinen et al., 2002b; Rittweger et al., 2003; Cormie et al., 2006 have been reported after a single WBV exposure ranging from 30 s to 10 min. The present study aimed at better characterizing the use of a single short bout of WBV as a mode of warming up before a CMJ test.A total of 114 university students (37 men, 77 women, aged 19.6 ± 2.0 years signed an informed consent form and volunteered to participate in the study. The study protocol was approved by the Review Committee for Research Involving Human Subjects of our center. Participants were asked to come to the laboratory in three occasions three days apart. First visit: familiarization session aiming to learn the CMJ technique and to experience the vibration stimulus. Second visit: the participants performed three consecutive CMJ with one min rest interval. No significant differences were observed among the jumps, and the highest score was retained. Third visit: the participants were exposed to a single short bout of WBV and immediately after they performed three CMJ with one min rest interval.An infrared contact timing platform (ERGO JUMP Plus - BOSCO SYSTEM, Byomedic, S.C.P., Barcelona, Spain was used to measure "flight" time (t during the vertical jump (accuracy 0.001 s. Maximum height achieved by the body centre of gravity (h was then estimated, i.e. h = g · t2 / 8, where g = 9.81 m/s2. In all occasions, the participants were instructed to abstain from strenuous exercise for the preceding 24 hours.Whole-body vibration was carried out on an oscillating

  3. Quantification of interstitial fluid on whole body CT: comparison with whole body autopsy.

    Science.gov (United States)

    Lo Gullo, Roberto; Mishra, Shelly; Lira, Diego A; Padole, Atul; Otrakji, Alexi; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Singh, Sarabjeet; Shepard, Jo-Anne O; Digumarthy, Subba R; Kalra, Mannudeep K; Stone, James R

    2015-12-01

    Interstitial fluid accumulation can occur in pleural, pericardial, and peritoneal spaces, and subcutaneous tissue planes. The purpose of the study was to assess if whole body CT examination in a postmortem setting could help determine the presence and severity of third space fluid accumulation in the body. Our study included 41 human cadavers (mean age 61 years, 25 males and 16 females) who had whole-body postmortem CT prior to autopsy. All bodies were maintained in the morgue in the time interval between death and autopsy. Two radiologists reviewed the whole-body CT examinations independently to grade third space fluid in the pleura, pericardium, peritoneum, and subcutaneous space using a 5-point grading system. Qualitative CT grading for third space fluid was correlated with the amount of fluid found on autopsy and the quantitative CT fluid volume, estimated using a dedicated software program (Volume, Syngo Explorer, Siemens Healthcare). Moderate and severe peripheral edema was seen in 16/41 and 7/41 cadavers respectively. It is not possible to quantify anasarca at autopsy. Correlation between imaging data for third space fluid and the quantity of fluid found during autopsy was 0.83 for pleural effusion, 0.4 for pericardial effusion and 0.9 for ascites. The degree of anasarca was significantly correlated with the severity of ascites (p < 0.0001) but not with pleural or pericardial effusion. There was strong correlation between volumetric estimation and qualitative grading for anasarca (p < 0.0001) and pleural effusion (p < 0.0001). Postmortem CT can help in accurate detection and quantification of third space fluid accumulation. The quantity of ascitic fluid on postmortem CT can predict the extent of anasarca.

  4. Whole-body measurements of workers occupationally exposed to radionuclides at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Cardoso, Joaquim Carlos S.; Xavier, Marcos

    2013-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters, whole body. NaIT1 (8x4″), and thyroid one, NaIT1 (3x3″). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that wasn't exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2007 to December 2012, approximately 6700 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  5. The public whole body counting program following the Three Mile Island accident. Technical report, April-September 1979

    International Nuclear Information System (INIS)

    Gotchy, R.L.; Bores, R.J.

    1980-12-01

    In early April, 1979 the U.S. Nuclear Regulatory instituted a program to determine whether any radioactivity released as a result of the March 28, 1979 accident at the Three Mile Island Unit-2 was accumulating in members of the general public living near Unit-2. The program used a device called a whole body counter which has the capability of measuring very small quantities of radioactivity in people. There were 753 men, women and children successfully counted; nine of these people were counted a second time, leading to a total of 762 whole body counts. There was no radioactivity identified in any member of the public which could have originated from the radioactive materials released following the accident. Several people with higher than average levels of naturally occurring radioactivity were identified. The counting systems used are briefly described. Technical problems encountered, results and conclusions are discussed

  6. Possibilities of whole-body MRI for investigating musculoskeletal diseases

    International Nuclear Information System (INIS)

    Lenk, S.; Claussen, C.D.; Schlemmer, H.P.; Fischer, S.; Koetter, I.

    2004-01-01

    This contribution outlines possibilities and limitations of whole-body MRI for investigating musculoskeletal diseases. Benefits and drawbacks of the novel whole-body MRI technology are discussed and a possible whole-body MRI sequence protocol for musculoskeletal examinations is proposed. Muscle, joint and bone diseases are discussed in which the application of whole-body MRI may be of advantage. Particularly, polymyositis, muscledystrophy, rheumatoid arthritis, spondylitis ancylosans, multiple trauma, skeletal metastases, multiple myeloma and malignant lymphoma are mentioned. Whole-body MRI opens new advantages for the examination of multifocal musculoskeletal diseases. The clinical benefit of this method for particular diseases has to be evaluated in further studies, however. (orig.) [de

  7. Fractional intestinal absorption and retention of calcium measured by whole-body counting. Application of a power function model

    International Nuclear Information System (INIS)

    Pors Nielsen, S.; Baerenholdt, O.; Munck, O.

    1975-01-01

    By application of a power function model, fractional intestinal calcium absorption was investigated with a new technique involving whole-body counting after successive oral and intravenous administration of standard doses of 47 Ca. The fractional calcium retention 7 days after the oral load of 47 Ca was also measured. Fractional calcium retention averaged 30.3% in normal subjects and 11.5% in 11 patients with intestinal malabsorption. In the same groups fractional calcium absorption averaged 46.6% and 16.4%, respectively. Fractional calcium retention and intestinal calcium absorption were significantly correlated to body surface area, and there was a well-defined relation between fractional retention and absorption of calcium. These studies demonstrate that measurements of fractional retention and fractional intestinal absorption of calcium can be combined by the use of a whole-body counter, that fractional retention and intestinal absorption are proportional to total body surface area and therefore probably also to the total bone mass, and that fractional retention and absorption are so closely interrelated that frational absorption can be estimated from fractional retention with reasonable accuracy in normal subjects. (auth.)

  8. Proposal of a methodology for evaluation of internal occupational exposure by Fluorine-18

    International Nuclear Information System (INIS)

    Oliveira, Cassio Miri

    2008-01-01

    The increasing use of 18 F for diagnostic procedures in nuclear medicine through PET technology leads to the growth in the number of occupationally exposed workers to this radionuclide, and consequently, increases up the probability of incorporation of this radionuclide. The external and internal exposures may occur during its clinical application 18 FDG and mainly during its production. Workers involved in such activities are usually monitored routinely for the control of external exposure. However it is important to provide methods for internal monitoring promptly after a suspicion of incorporation. Therefore, the objective of this work is to develop procedures for internal monitoring of 18 F to be applied in cases of possible incorporation of ions fluoride and 18 FDG radiopharmaceutical, using in vivo and in vitro methods of measurements. The NaI(Tl) 8'' x 4'' scintillation detector of the IRD-Whole Body Counter was calibrated for in vivo measurements with a whole body anthropomorphic phantom simulating incorporation by 18 F in the form of fluoride ions due to the homogeneous distribution of this substance in the body. The Nal(Tl) 3'' x 3'' scintillation detector of the IRD-Whole Body Counter was calibrated for in vivo measurements with a brain phantom inserted in an artificial skull simulating incorporation by 18 F in the form 18FDG due to the high absorption of this substance by brain. HPGe detection system of the IRD-Bioassay Laboratory was calibrated for in vitro measurements of urine samples. It was used 1 liter plastic bottles containing standardized radioactive source. A methodology for bioassay data interpretation based on standard ICRP models edited with the software AIDE-version 6 was established. It is concluded that in vivo measurements for the evaluation of incorporation of 18 F in the form of fluoride and 18 FDG have sufficient sensitivity to detect effective doses of 4,4 x 10 -6 and 1,55 x 10 5 mSv, respectively, i.e., below the recording level of

  9. Whole body imaging

    International Nuclear Information System (INIS)

    de Luca, P.C.; Stoddart, H.F.; Jeffries, D.

    1976-01-01

    A whole body imaging system rapidly forms a quality image of the bony structure, soft tissue or specific organs of a patient who has been injected with a suitable radioactive tracer chemical. A radiation detector head assembly includes a number of detector subassemblies, each having a lead collimator with tapered holes for admitting gamma radiation from a small area of the patient to a scintillation crystal that converts the gamma rays admitted by the collimator into visible or ultraviolet energy pulses. A photomultiplier converts these pulses into electrical pulses. A row of equally spaced detector subassemblies reciprocate within a nonreciprocating lead shield along the long axis of the array over a distance substantially equal to the separation between adjacent ones of the small areas. Associated electronic and electromechanical apparatus control the reciprocating motion and the longitudinal motion of the radiation detector head assembly, and process the photodetected signals to produce in a relatively short time a visible image of the radiant energy emanating from the whole body of the patient scanned

  10. Anisotropy of neutron sources of Neutron Metrology Laboratory, IRD, Brazil

    International Nuclear Information System (INIS)

    Silva, A.C.F.; Silva, F.S.; Leite, S.P.; Creazolla, P.G; Patrão, K.C.S.; Fonseca, E.S. da; Fernandes, S.S.; Pereira, W.W.

    2017-01-01

    The anisotropy measurements have as main objective to define the emission of the radiation by different angles of an encapsulated neutron source. The measurements were performed using a Long Accuracy Counter (PLC) Detector in the Low Dispersion Room of the LNMRI / IRD with different neutron sources. Each measurement was made using a support for the source, emulated through an arduino system to rotate it. The carrier is marked with a variation of 5 °, ranging from 0 ° to 360 °, for the work in question only half, 0 ° to 180 ° is used for a total of nineteen steps. In this paper three sources of "2"4"1AmBe (α, n) 5.92 GBq (16 Ci) were used, neutron sources having the following dimensions: 105 mm in height and 31 mm in diameter. The PLC was positioned at a distance of 2 meters from the neutron source and has a radius of 15 cm for the detection area. The anisotropy factor of the "2"4"1AmBe source was 17%. The results in this work will focus mainly on the area of radioprotection and studies that will improve the process of routine measurements in laboratories and instrument calibrations. (author)

  11. Body load in heel-strike running: the effect of a firm heel counter.

    Science.gov (United States)

    Jørgensen, U

    1990-01-01

    The effect of a firm heel counter in the shoe was studied in 11 athletes during submaximal heel-strike running on a treadmill under standardized conditions. The runners were tested in identical shoes with and without the distal 2 cm of the firm heel counter. Body load was expressed by absolute and relative VO2, surface EMG on the right leg, and g-force registration from an accelerometer below the right tibial tuberosity. The heel counter caused a 2.4% significant decrease in VO2, a reduction in musculoskeletal transients, and a decrease in the activity of the triceps surae and quadriceps muscles at heel strike. The changes found are expressions of kinematic adaptations in the body to increased or decreased load and provide functional evidence for the loading factor in the pathophysiology of overuse injuries.

  12. Participation of IRD/CNEN-Br in International Intercomparison of Criticality Accident Dosimetry Systems at Silene reactor, France

    International Nuclear Information System (INIS)

    Mauricio, Claudia Lucia P.; Fonseca, Evaldo S. da

    1996-01-01

    IRD has participated in an International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE reactor, France on June 1993. The dosemeters were irradiated on phantoms and free in air, in bare and lead shield reactor pulses, simulating different irradiation fields that can be found in criticality accidents. Comparing with the reference measurements, the calculated mean neutron kerma found by IRD was only 2% greater for lead shield and 14% greater for bare reactor. For gamma absorbed dose, the differences were, respectively + 22% and -9% for the dosemeters free in air and -19% and -9% for dosemeters on phantoms. IRD results are closer to the real values than the mean values measured by the participants. IRD results show a good performance if its simple criticality accident system. (author)

  13. Quantitative whole body scintigraphy - a simplified approach

    International Nuclear Information System (INIS)

    Marienhagen, J.; Maenner, P.; Bock, E.; Schoenberger, J.; Eilles, C.

    1996-01-01

    In this paper we present investigations on a simplified method of quantitative whole body scintigraphy by using a dual head LFOV-gamma camera and a calibration algorithm without the need of additional attenuation or scatter correction. Validation of this approach to the anthropomorphic phantom as well as in patient studies showed a high accuracy concerning quantification of whole body activity (102.8% and 97.72%, resp.), by contrast organ activities were recovered with an error range up to 12%. The described method can be easily performed using commercially available software packages and is recommendable especially for quantitative whole body scintigraphy in a clinical setting. (orig.) [de

  14. The A.R.L. whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1990-02-01

    This report describes a Whole Body Monitor based on four uncollimated NaI(Tl) detectors in a static geometry in use at the Australian Radiation Laboratory. A detailed discussion is presented on the methodology used to estimate the detector efficiency for any arbitrary source whose shape can be described analytically. This procedure is valid for photon emitters in the range 120 keV to 2.6 MeV. By the use of simple geometric models, this approach is applied to the whole body as well as for certain internal organs. For lower photon energies, a discussion of methods using NaI(Tl) detectors to detect in-vivo sources by analysis of pulse-height spectra, is presented. In addition, the application of the Whole Body Monitor in the study of human calcium metabolism, using the tracer 47 Ca is described. Results of measurments on the natural activity of possible candidates for components of the concrete base of the Whole Body Monitor are presented. 74 refs., 22 tabs., 40 figs

  15. Whole-body measurements of workers occupationally exposed to radionuclides at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Cardoso, Joaquim Carlos S.; Xavier, Marcos

    2015-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters, whole body. NaITl (8 x 4”), and thyroid one, NaITl (3 x 3”). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that was not exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2010 to December 2014, approximately 4500 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  16. The assessment of whole body bone SPECT in oncology

    International Nuclear Information System (INIS)

    Scortechini, Shonika

    2009-01-01

    Full text: Objectives: To assess the significance and practicability of oncology whole body bone SPECT as part of the standard skeletal survey and its impact on the traditional planar whole body bone imaging protocol. Method: Three consenting oncology patients were injected with a standard adult dose of Tc-99m MOP. Delayed Imaging of whole body sweep and SPECT acquisitions were performed on a Siemens Symbia T6. The patient was positioned supine with arms down with a SPECT scan length covering vortex to thighs. SPECT data was reconstructed and a single whole body zipped file created. Normal SPECT slices along with a cine/MIP of the zipped data were created for review. Results: Both image data sets were reviewed to assess if SPECT provided any further diagnostic clinical information not apparent in planer imaging. In our limited review, whole body SPECT did not add extra value to the planar whole body scans performed; it did however demonstrate vertebral involvement with greater resolution. The processing software and system limitations in seamlessly knitting data sets (creating image artefacts) was a major limiting factor in not pursuing further studies. Conclusion: Both imaging techniques offer differing advantages and limitations, however due to image artefact in the triple knitted SPECT approach with current software technology, it cannot be substituted for whole body imaging at this time.

  17. Advanced CUBIC protocols for whole-brain and whole-body clearing and imaging.

    Science.gov (United States)

    Susaki, Etsuo A; Tainaka, Kazuki; Perrin, Dimitri; Yukinaga, Hiroko; Kuno, Akihiro; Ueda, Hiroki R

    2015-11-01

    Here we describe a protocol for advanced CUBIC (Clear, Unobstructed Brain/Body Imaging Cocktails and Computational analysis). The CUBIC protocol enables simple and efficient organ clearing, rapid imaging by light-sheet microscopy and quantitative imaging analysis of multiple samples. The organ or body is cleared by immersion for 1-14 d, with the exact time required dependent on the sample type and the experimental purposes. A single imaging set can be completed in 30-60 min. Image processing and analysis can take whole-brain neural activities at single-cell resolution using Arc-dVenus transgenic (Tg) mice. CUBIC informatics calculated the Venus signal subtraction, comparing different brains at a whole-organ scale. These protocols provide a platform for organism-level systems biology by comprehensively detecting cells in a whole organ or body.

  18. Whole body scan system based on γ camera

    International Nuclear Information System (INIS)

    Ma Tianyu; Jin Yongjie

    2001-01-01

    Most existing domestic γ cameras can not perform whole body scan protocol, which is of important use in clinic. The authors designed a set of whole body scan system, which is made up of a scan bed, an ISA interface card controlling the scan bed and the data acquisition software based on a data acquisition and image processing system for γ cameras. The image was obtained in clinical experiment, and the authors think it meets the need of clinical diagnosis. Application of this system in γ cameras can provide whole body scan function at low cost

  19. Whole-body MR imaging of bone marrow

    International Nuclear Information System (INIS)

    Schmidt, G.P.; Schoenberg, S.O.; Reiser, M.F.; Baur-Melnyk, A.

    2005-01-01

    In clinical routine, multimodality algorithms, including X-ray, computed tomography, scintigraphy and MRI, are used in case of suspected bone marrow malignancy. Skeletal scintigraphy is widely used to asses metastatic disease to the bone, CT is the technique of choice to assess criteria of osseous destruction and bone stability. MRI is the only imaging technique that allows direct visualization of bone marrow and its components with high spatial resolution. The combination of unenhanced T1-weighted-spin echo- and turbo-STIR-sequences have shown to be most useful for the detection of bone marrow abnormalities and are able to discriminate benign from malignant bone marrow changes. Originally, whole-body MRI bone marrow screening was performed in sequential scanning techniques of five body levels with time consuming coil rearrangement and repositioning of the patient. The introduction of a rolling platform mounted on top of a conventional MRI examination table facilitated whole-body MR imaging and, with the use of fast gradient echo, T1-weighted and STIR-imaging techniques, for the first time allowed whole-body imaging within less than one hour. With the development of parallel imaging techniques (PAT) in combination with global matrix coil concepts, acquisition time could be reduced substantially without compromises in spatial resolution, enabling the implementation of more complex and flexible examination protocols. Whole-body MRI represents a new alternative to the stepwise multimodality concept for the detection of metastatic disease, multiple myeloma and lymphoma of the bone with high diagnostic accuracy

  20. Measurement of Organ Uptake by Whole-Body Counting

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1970-01-01

    This paper reviews methods for the measurement of radioactivity in body organs based on whole-body radioactivity measurements. Such measurements can of course only be used to measure radioactivity in a body organ when the radioactivity is exclusively localized in the organ or when the ratio of radioactivity in the organ to that in the whole body is known from other sources of information. They find particular applications, however, when the organ is so widely dispersed throughout the body that more localized measurement is impossible. Examples of situations in which whole-body radioactivity measurements have been used in this way are cited. The more important techniques used for such measurements are described and their respective advantages and disadvantages indicated. The importance of uniformity of counting efficiency with position of source throughout the body is stressed. Simple systems incorporating sodium iodide crystal scintillation detectors are shown to combine satisfactory sensitivity and uniformity of efficiency for clinical measurements of radioactivity in body organs and have the additional advantage that they can be readily adapted for profile scanning. Systems incorporating plastic or liquid scintillation detectors are less convenient in this respect. (author)

  1. Radiological impact of the Chernobyl accident through ingestion in Europe. Ingestion doses determined by whole-body counting of radiocesium

    International Nuclear Information System (INIS)

    Inaba, Jiro

    2012-01-01

    Reports mainly concerning the internal exposure caused by Chernobyl Accident (CA, 1986) are discussed for reference to deal with the radiation impact on public of Fukushima Daiichi Power Plant Accident. Data of the internal exposure measured by the whole body counter are particularly noted. In adults, 1 kBq of Cs-137/body/year is equivalent to the internal exposure dose of 0.03 mSV/y. The CA released Cs-137 of total 8.5 PBq, which was then partially ingested through food to result in the internal exposure to European. For instance, in the old Soviet, the exposure was reported to amount to about 100 kBq/body (1987) of residents living in the highly contaminated area (Bryansk and others). In southern Germany like Bavaria State, the amount >1 kBq/body was recorded in 1987. In Cumbria, UK, residents had about 700 Bq of Cs-137 in June, 1986, which decreased to 450 Bq a month later. In Sami people living in Lapland area of northern Scandinavia, several tens kBq/body were found as they took the meat of reindeer of which diet was the contaminated lichen. The amount of internal Cs-137 peaked in 1987 and lowered thereafter with half lives of 1-2 years, which was thought to be partly due to various protection means conducted. The internal half life tended to elongate in people who had ingested the food harvested from such sites as difficult to get rid of the contamination like forest. Overall, the internal amount/dose of Cs-137 due to CA were at a similar level to those to the nuclear experiments in open air done in 1960s. The author, based on his experience, thinks that it can be one of relevant ways to observe the time course of the internal dose change of certain typical residents in Fukushima by measuring with the whole body counter, followed by announcement and explanation of data to the public. (T.T.)

  2. Holocene climate and fjord glaciations in Northeast Greenland: implications for IRD deposition in the North Atlantic

    DEFF Research Database (Denmark)

    Reeh, Niels

    2004-01-01

    been released by intensive sub-glacial melting during the long stay of the ice-islands in coastal waters. The Holocene glacial geological record from Northeast Greenland is compared to the record of ice rafted debris (IRD) from North Atlantic deep-sea sediment cores. The comparison shows that transport...... by icebergs in the form of basal debris is unlikely to be the dominant transport mechanism of IRD to deposition sites in the North Atlantic during the Holocene. The ice rafted debris is more likely to be carried at the surface of sea- (or glacier) ice. This supports the result of previous studies by other...... workers that changes of atmospheric and ocean-surface circulation and temperature are the likely causes of Holocene cycles in IRD concentration in North Atlantic deep-sea sediments....

  3. Estimation of Total Body Fat from Potassium-40 Content

    International Nuclear Information System (INIS)

    Taha Mohamed Taha Ahmed, T.M.T.

    2010-01-01

    This paper concerns on estimation of total body fat from potassium 40 content using total body counting technique. The work performed using fast scan whole body counter. Calibration of that system for K-40 was carried out under assumption that uniformity distribution of radioactivity of potassium was distributed in 10 polyethylene bottles phantom. Different body sizes were represented by 2, 4, 6, 8 and 10 polyethylene bottles; each bottle has a volume of 0.04 m3. The counting efficiency for each body size was determined. Lean body weight (LBW) was calculated for ten males and ten females using appropriate mathematical equation. Total Body Potassium, TBK for the same selected group was measured using whole body counter. A mathematical relationship between lean body weight and potassium content was deduced .Fat contents for some individuals were calculated and weight/height ratio was indicated for fatness.

  4. Whole-body counting of Fukushima residents after the TEPCO Fukushima Daiichi Nuclear Power Station accident

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Takumaro; Takada, Chie; Nakagawa, Takahiro; Nakai, Katsuta; Kurihara, Osamu; Tsujimura, Norio; Furuta, Sadaaki [Japan Atomic Energy Agency, Nuclear Fuel Cycle Engineering Laboratories, Tokai, Ibaraki (Japan); Ohi, Yoshihiro; Murayama, Takashi; Suzuki, Takashi [Japan Atomic Energy Agency, Nuclear Science Research Institute, Tokai, Ibaraki (Japan); Uezu, Yasuhiro [Japan Atomic Energy Agency, Fukushima Environmental Safety Center, Fukushima, Fukushima (Japan)

    2012-11-15

    At the request of the Fukushima government, the Japan Atomic Energy Agency (JAEA) started whole-body counting of residents on July 11, 2011, to assess radiation exposure after the TEPCO Fukushima Daiichi Nuclear Power Station accident. JAEA has examined residents in Iitate, Kawamata, Namie, and eight other local communities. The measurement capacity of the whole-body counting device is approximately 100 persons per day, and the total number of people to measure reached 9,927 by the end of January 2012. Two types of whole-body counter (WBC), each of which has two large-sized NaI(Tl) detectors, were used to perform the measurements. Physical phantoms (a Canberra RMC-II transfer phantom or a water-filled block phantom developed by JAEA) were used to perform the efficiency calibration of the WBCs, and results of this calibration were verified by comparing them with different-sized BOttle Mannequin ABsorber (BOMAB) phantoms imitating an adult male, a 10-year-old child, and a 4-year-old child. Short half-life radionuclides (e.g., {sup 131}I) originating from the accident were not detected in the present work, because the measurements were made starting four months after the accident. These measurements showed that about 80% of the residents were below a minimum detectable amount (MDA) of the measured radionuclides in the whole-body content. No artificial nuclides other than {sup 134}Cs and {sup 137}Cs were detected in the present whole-body counting. The maximum whole-body content of radiocesium ({sup 134}Cs and {sup 137}Cs in total) was 2.7 kBq for children (< 8 years old) and 14 kBq for adults. The radioactivity ratio ({sup 137}Cs/{sup 134}Cs) was estimated to be from 1.12 to 1.26. An acute intake scenario via inhalation of radiocesium was assumed in the present dose estimation for all the residents who were measured by the end of January 2012. The committed effective dose (CED) to 99.8% of the residents was found to be below 1 mSv. There were only 25 subjects with a

  5. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  6. In-vivo radiation counter

    International Nuclear Information System (INIS)

    Pollard, D.E.

    1983-01-01

    This patent specification describes a radiation counter utilizing at least one detector for sensing radiation from a living body. The radiation counter also includes an aperture for forming a corridor between the body and the detector. A shield outside the corridor prevents passage of background radiation through the corridor and gaining access to the detector. The counter also includes a device for isolating a selected portion of the body from the corridor such that radiation counting is restricted to a region of the body through a separate detector. The corridor formation permits a user to stand in an upright position while the detector and detectors are able to separately monitor different sections of the body. The radiation counter overcomes the problem of obtaining accurate and quick measurements or radiation doses sustained by a large group of persons. (author)

  7. Human whole body cold adaptation.

    NARCIS (Netherlands)

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced

  8. Development of a computational system for monitoring data management in vivo of the radionuclides in human body

    International Nuclear Information System (INIS)

    Reis, Arlene A. dos; Lucena, Eder A. de; Dantas, Ana Leticia A.; Dantas, Bernardo M.

    2014-01-01

    The management of in vivo monitoring process of internal contamination by radionuclides in human beings request a set of steps ranging from the spectrum acquisition to reporting. The spectrum analysis is the identification and quantification of radioactive materials present in organs and individual's body tissues submitted to monitoring procedures. The Body Counter Unit of IRD performs in vivo measurements emitting radionuclide photons in the 10-3000 keV energy range, using NaI type scintillation detectors (Tl) 8” x 4” and 3” x 3” and as semiconductor detectors type HPGe. The measuring system uses the Canberra Genie 2000 software for the acquisition of spectra with 1024 channels related to their respective energies. The counting are distributed in the spectrum due to the energy of the photons emitted by radionuclides of interest. The SIGMIV program (System for Management of in vivo monitoring), developed in MS Visual Basic 2010 accesses the spectrum after it is converted into an EXCEL spreadsheet. This program uses a bank Data developed in MS-Access to store information associated with each measurement, as counting and calibration parameters. SIGMIV generates a report containing personal information, activity and radionuclides of interest present in the body, associated with respective uncertainties and minimum activity detectable. The program SIGMIV optimized monitoring procedures 'in vivo', showing that is flexible, reliable and easy to handle, thus becoming an important tool for development routine in In vivo Monitoring Laboratory of IRD

  9. Proposal for the improvement of IRD safety culture based on risk analysis

    International Nuclear Information System (INIS)

    Aguiar, L.A.; Ferreira, P.R.R.; Silveira, C.S.

    2017-01-01

    The Safety Culture (SC) is a concept about the relationship of individuals and organizations towards the safety in a specific activity. Any organization that carries out activities with risks has a SC, even at minimum levels. People perceive different types of radiation risks in very different ways, therefore, to identify and to analysis of the possible radiation risks resulting from normal operation or accident conditions is an important issue in order to improve the SC in organization. The main is to present guidelines for the improvement of the safety culture in the Institute of Radiation Protection and Dosimetry - IRD through on risk-based approach. The methodology proposed here is: A) select a division of the IRD for case study; B) assess the level of the 10 culture safety basic elements of the IRD division selected; C) conduct a survey of the hazards and risks associated with the various activities developed by the division; D) reassess the level of the 10 basic elements of CS; And E) analyze the results and correlate the impact of risk knowledge on safety culture improvement. The expected result is improvement the safety and of safety culture by understanding of radiation risks and hazards relating to work and to the working environment; and thus enforce a collective commitment to safety by teams and individuals and raise the safety culture to higher levels. (author)

  10. Proposal for the improvement of IRD safety culture based on risk analysis

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, L.A.; Ferreira, P.R.R. [Instituto de Radioproteção e Dosimetria (DIRAD/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Silveira, C.S., E-mail: laguiar@ird.gov.br [Comissão Nacional de Energia Nuclear (DRS/CGMI/CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The Safety Culture (SC) is a concept about the relationship of individuals and organizations towards the safety in a specific activity. Any organization that carries out activities with risks has a SC, even at minimum levels. People perceive different types of radiation risks in very different ways, therefore, to identify and to analysis of the possible radiation risks resulting from normal operation or accident conditions is an important issue in order to improve the SC in organization. The main is to present guidelines for the improvement of the safety culture in the Institute of Radiation Protection and Dosimetry - IRD through on risk-based approach. The methodology proposed here is: A) select a division of the IRD for case study; B) assess the level of the 10 culture safety basic elements of the IRD division selected; C) conduct a survey of the hazards and risks associated with the various activities developed by the division; D) reassess the level of the 10 basic elements of CS; And E) analyze the results and correlate the impact of risk knowledge on safety culture improvement. The expected result is improvement the safety and of safety culture by understanding of radiation risks and hazards relating to work and to the working environment; and thus enforce a collective commitment to safety by teams and individuals and raise the safety culture to higher levels. (author)

  11. Image fusion between whole body FDG PET images and whole body MRI images using a full-automatic mutual information-based multimodality image registration software

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Nakano, Yoshitada; Fujibuchi, Toshiou; Isobe, Tomoko; Kazama, Toshiki; Ito, Hisao

    2006-01-01

    We attempted image fusion between whole body PET and whole body MRI of thirty patients using a full-automatic mutual information (MI) -based multimodality image registration software and evaluated accuracy of this method and impact of the coregistrated imaging on diagnostic accuracy. For 25 of 30 fused images in body area, translating gaps were within 6 mm in all axes and rotating gaps were within 2 degrees around all axes. In head and neck area, considerably much gaps caused by difference of head inclination at imaging occurred in 16 patients, however these gaps were able to decrease by fused separately. In 6 patients, diagnostic accuracy using PET/MRI fused images was superior compared by PET image alone. This work shows that whole body FDG PET images and whole body MRI images can be automatically fused using MI-based multimodality image registration software accurately and this technique can add useful information when evaluating FDG PET images. (author)

  12. Placement of HPGE detectors for whole body counting applications using simulations of voxel phantoms

    International Nuclear Information System (INIS)

    Marzocchi, O.; Breustedt, B.; Zankl, M.

    2010-01-01

    The partial body counter at KIT is going to be rebuilt in order to replace the old Ge detectors with four new HPGe detectors. The new installation will also add whole body capabilities to the system, thanks to an improved mechanics able to position the detectors with a high degree of freedom in the chamber. During the definition of the position of the detectors a compromise between the opposite goals of high efficiency and small dependence of the detection efficiency on the position of the source had to be sought. High detection efficiency involves placing the detector near the skin, where the photon flux is maximal, while the second goal involves placing the detectors at a greater distance from the body. The same concept was applied during the definition of the partial body measurement configurations, but the goal was the increase of the specificity of the measurement. In addition, the mechanical installation poses some constraints: two detectors are mounted on carts and therefore can be placed independently around the subjects, but not in front of it, while the other two detectors are mounted on carts hanging from the same rail on the ceiling, therefore their distance from the subject is constrained by the maximum offset between them. (orig.)

  13. Whole body MRI in children; Ganzkoerper-MRT bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Juergen F.; Tsiflikas, Ilias [Tuebingen Univ. (Germany). Bereich Kinderradiologie

    2014-09-15

    In pediatric patients whole body MRI has a relevant impact on both, diagnostic work-up and treatment. Using adapted sequence protocols comprehensive imaging without radiation exposure is possible avoiding additional examinations in many cases. Especially in bone marrow the differentiation between normal and abnormal finding can be difficult, therefore the knowledge of normal maturing of organs is important. Whole body diffusion weighted imaging particularly in neuroblastomas or sarcomas improves the low specificity of conventional MR-protocols. Technical prerequisites, examination protocol and strategies, image interpretation, indications and clinical relevance as well as advantages and disadvantages of whole body MRI will be discussed on the basis of application-oriented cases and the literature.

  14. INSOMNIA DAN DIAGNOSIS PSIKIATRI PADA PASIEN DI INSTALASI RAWAT DARURAT (IRD RSUP SANGLAH

    Directory of Open Access Journals (Sweden)

    Alfa Matrika Sapta Dewanti

    2015-01-01

    Full Text Available Insomnia adalah suatu kesulitan dalam memulai tidur, mempertahankan tidur, atau tiduryang tidak menyegarkan selama 1 bulan atau lebih di mana keadaan sulit tidur ini harusmenyebabkan gangguan klinis yang signifikan. Insomnia dibagi menjadi insomnia primerdan sekunder. Penelitian ini merupakan penelitian deskriptif yang bertujuan untukmenjelaskan karakteristik insomnia dan diagnosis psikiatri pada pasien di Instalasi RawatDarurat (IRD RSUP Sanglah. Data penelitian ini berdasarkan register pasien IRD RSUPSanglah periode Mei-November 2013. Sampel yang memenuhi kriteria inklusi ini terdiridari 52 laki-laki (49% dan 54 perempuan (51%. Menurut tipe insomnia, 17% insomniaprimer dan 83% insomnia sekunder. Berdasarkan usia, 11% pada usia  ?20 tahun, 32%pada usia 21-30 tahun, usia 31-50 tahun  40% dan 17% pada usia>50 tahun. Pasien yangmenikah 51%, belum menikah 39%, janda 6% dan duda 4%. Pasien yang bekerja 56% dan44% tidak bekerja. Berdasarkan diagnosis psikiatri, skizofrenia 20 (22,7%, psikotik akut17 (19,3%, depresi  12 (13,6%, bipolar 7 (8%, delirium 8 (9,1%, GMO 10 (11,4% dangangguan penyesuaian 14 (15,9%. Dari keseluruhan pasien insomnia yang datang ke IRD,17% merupakan insomnia primer dan 83% insomnia sekunder. Diagnosis psikiatri pasieninsomnia terbanyak adalah pasien psikotik, yaitu skizofrenia 22,7% dan psikotik akut19,3%.

  15. Human and animal studies: portals into the whole body and whole population response

    Science.gov (United States)

    Human and animal studies: portals into the whole body and whole population response Michael C. Madden1 and Brett Winters21US Environmental Protection Agency and 2University of North Carolina Human Studies Facility, Chapel Hill, North Carolina, USA Studies involving collection and...

  16. Overview of environmental radiological monitoring program of Institute of Radiation Protection And Dosimetry - IRD

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Sarah Barreto Oliveira de Christo; Peres, Sueli da Silva, E-mail: suelip@ird.gov.br, E-mail: sarah.barreto1@gmail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Radioproteção

    2017-07-01

    As a branch of the Brazilian Nuclear Energy Commission (CNEN), the Institute of Radiation Protection and Dosimetry (IRD) performs extensive activities in the fields of radiation protection, metrology, and dosimetry, as well as specific education, onto a wide operational scope that includes the technical support to national regulatory authorities in the licensing process for nationwide nuclear and radioactive facilities. IRD has several laboratories where are performed radiometric and radiochemical analyses and others radioactivity evaluation procedures in different types of samples obtained in the inspection activities, production of radioactivity metrological standards and reference material by National Laboratory of Metrology of Ionizing Radiation (LMNRI), besides others research activities. In this laboratories can be used sealed or unsealed radioactive sources and radiation-producing devices and are classified with radioactive installations in accordance to national regulations. This way, radioactive liquid effluents can be eventually produced and released into the environment in the course of such activities and an effluent monitoring program to control and reduce the releases to environment is carried out. Additionally, IRD maintains the Radioactive Waste Management Program and Environmental Radiological Monitoring Program (ERMP) in accordance to national regulations requirements. The primary focus of ERMP comprises the validation of the dose prognostics for the public members due to effluents discharge and the provision of consistent projections of the radiation levels at the monitoring sites. In this study, a long term ERMP data survey is discussed, spanning the last thirteen years of activities. On the basis of such discussions and prognostics, it could be observed that the radiological environmental radiological impact due to operation of IRD installations is negligible. (author)

  17. Overview of environmental radiological monitoring program of Institute of Radiation Protection And Dosimetry - IRD

    International Nuclear Information System (INIS)

    Gomes, Sarah Barreto Oliveira de Christo; Peres, Sueli da Silva

    2017-01-01

    As a branch of the Brazilian Nuclear Energy Commission (CNEN), the Institute of Radiation Protection and Dosimetry (IRD) performs extensive activities in the fields of radiation protection, metrology, and dosimetry, as well as specific education, onto a wide operational scope that includes the technical support to national regulatory authorities in the licensing process for nationwide nuclear and radioactive facilities. IRD has several laboratories where are performed radiometric and radiochemical analyses and others radioactivity evaluation procedures in different types of samples obtained in the inspection activities, production of radioactivity metrological standards and reference material by National Laboratory of Metrology of Ionizing Radiation (LMNRI), besides others research activities. In this laboratories can be used sealed or unsealed radioactive sources and radiation-producing devices and are classified with radioactive installations in accordance to national regulations. This way, radioactive liquid effluents can be eventually produced and released into the environment in the course of such activities and an effluent monitoring program to control and reduce the releases to environment is carried out. Additionally, IRD maintains the Radioactive Waste Management Program and Environmental Radiological Monitoring Program (ERMP) in accordance to national regulations requirements. The primary focus of ERMP comprises the validation of the dose prognostics for the public members due to effluents discharge and the provision of consistent projections of the radiation levels at the monitoring sites. In this study, a long term ERMP data survey is discussed, spanning the last thirteen years of activities. On the basis of such discussions and prognostics, it could be observed that the radiological environmental radiological impact due to operation of IRD installations is negligible. (author)

  18. whole body vibration and spinal stabilisation

    African Journals Online (AJOL)

    A range of exercise modalities is used in the rehabilitation of indi- viduals with chronic lower ... effects of whole body vibration (WBV) therapy and conventional ... with musculoskeletal, sensory, emotional, cognitive and behavioural components ...

  19. The effects of a single whole body cryotherapy exposure on physiological, performance and perceptual responses of professional academy soccer players following repeated sprint exercise

    OpenAIRE

    Russell, Mark; Birch, Jack; Love, Thomas; Cook, Christian; Bracken, Richard M.; Taylor, Tom; Swift, Eamon; Cockburn, Emma; Finn, Charlie; Cunningham, Daniel; Wilson, Laura; Kilduff, Liam P.

    2017-01-01

    In professional youth soccer players, the physiological, performance and perceptual effects of a single whole body cryotherapy (WBC) session performed shortly after repeated sprint exercise were investigated. In a randomized, counter-balanced and crossover design, 14 habituated English Premier League academy soccer players performed 15 x 30 m sprints (each followed by a 10 m forced deceleration) on two occasions. Within 20 min of exercise cessation, players entered a WBC chamber (Cryo: 30 s a...

  20. Whole-body irradiation in case of malignant lymphomas of low malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Labedzki, L; Schmidt, R E; Hartlapp, J H; Illiger, H J; Frommhold, H; Boldt, I

    1982-04-01

    27 consecutive patients with malignant lymphomas were submittet to whole-body irradiations with doses of 0.5 to 3 Gy. Among these patients ten had been treated before. There were two complete and 16 partial remissions. The condition of five patients could not be considerably improved. Four patients showed a tumor progression during the time of bone marrow depression. The remission period was 11.5 (3 to 22 +) months. The hematologic side effects were considerable; in ten cases, the whole-body irradiation could not be continued because of a thrombocytopenia or an aplastic syndrome. A remarkable fact was the appearance of symptoms similar to that of lupus erythematodes in two patients. An inefficacy of whole-body irradiation did not exclude a response to subsequent chemotherapy. Our own experiences allow to make the following conclusion: in most of all patients with malignant lymphomas of low malignancy a measurable tumor reduction is achieved by whole-body irradiation. Because of the hematologic side effects a whole-body irradiation should be applied only in cases of malignant lymphomas of low malignancy the slow growth of which is proved by observation and which have not been treated before. The thrombocyte numbers should be above 100 000/..mu..l before therapy. Otherwise, the whole-body irradiation has to be stopped before the intended effective dose is reached because of an inevitably developing thrombocytopenia. A whole-body irradiation in case of a malignant lymphoma of low grade malignancy necessitates strict follow-up examinations conducted at regular intervals for a period of at least six weeks after the irradiation. The whole-body irradiation should never be applied as ultima ratio.

  1. The whole body counting experience on the internal contamination of radionuclides at IPEN/CNEN-SP, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Joaquim C.S.; Xavier, Marcos, E-mail: jcardoso@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters whole body. NalTl ( 8 x 4″), and thyroid one, NaITl (3 x 3″). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that was not exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2012 to December 2016, approximately 3800 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  2. The whole body counting experience on the internal contamination of radionuclides at IPEN/CNEN-SP, Brazil

    International Nuclear Information System (INIS)

    Cardoso, Joaquim C.S.; Xavier, Marcos

    2017-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters whole body. NalTl ( 8 x 4″), and thyroid one, NaITl (3 x 3″). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that was not exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2012 to December 2016, approximately 3800 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  3. Automatic anatomy recognition in whole-body PET/CT images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huiqian [College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China and Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu; Odhner, Dewey; Tong, Yubing; Torigian, Drew A. [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Zhao, Liming [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 and Research Center of Intelligent System and Robotics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China)

    2016-01-15

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  4. Automatic anatomy recognition in whole-body PET/CT images

    International Nuclear Information System (INIS)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.; Zhao, Liming

    2016-01-01

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  5. Whole-body impedance control of wheeled humanoid robots

    CERN Document Server

    Dietrich, Alexander

    2016-01-01

    Introducing mobile humanoid robots into human environments requires the systems to physically interact and execute multiple concurrent tasks. The monograph at hand presents a whole-body torque controller for dexterous and safe robotic manipulation. This control approach enables a mobile humanoid robot to simultaneously meet several control objectives with different pre-defined levels of priority, while providing the skills for compliant physical contacts with humans and the environment. After a general introduction into the topic of whole-body control, several essential reactive tasks are developed to extend the repertoire of robotic control objectives. Additionally, the classical Cartesian impedance is extended to the case of mobile robots. All of these tasks are then combined and integrated into an overall, priority-based control law. Besides the experimental validation of the approach, the formal proof of asymptotic stability for this hierarchical controller is presented. By interconnecting the whole-body ...

  6. Radiation exposure in whole body CT screening.

    Science.gov (United States)

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  7. Whole-body intravoxel incoherent motion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Wurnig, Moritz C.; Eberhardt, Christian; Guggenberger, Roman; Boss, Andreas [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Luechinger, Roger [University and ETH Zurich, Institute of Biomedical Technology, Zurich (Switzerland)

    2015-07-15

    To investigate the technical feasibility of whole-body intravoxel incoherent motion (IVIM) imaging. Whole-body MR images of eight healthy volunteers were acquired at 3T using a spin-echo echo-planar imaging sequence with eight b-values. Coronal parametrical whole-body maps of diffusion (D), pseudodiffusion (D*), and the perfusion fraction (F{sub p}) were calculated. Image quality was rated qualitatively by two independent radiologists, and inter-reader reliability was tested with intra-class correlation coefficients (ICCs). Region of interest (ROI) analysis was performed in the brain, liver, kidney, and erector spinae muscle. Depiction of anatomic structures was rated as good on D maps and good to fair on D* and F{sub p} maps. Exemplary mean D (10{sup -3} mm{sup 2}/s), D* (10{sup -3} mm{sup 2}/s) and F{sub p} (%) values (± standard deviation) of the renal cortex were as follows: 1.7 ± 0.2; 15.6 ± 6.5; 20.9 ± 4.4. Inter-observer agreement was ''substantial'' to ''almost perfect'' (ICC = 0.80 - 0.92). The coefficient of variation of D* was significantly lower with the proposed algorithm compared to the conventional algorithm (p < 0.001), indicating higher stability. The proposed IVIM protocol allows computation of parametrical maps with good to fair image quality. Potential future clinical applications may include characterization of widespread disease such as metastatic tumours or inflammatory myopathies. (orig.)

  8. Whole-body magnetic resonance imaging in axial spondyloarthritis

    DEFF Research Database (Denmark)

    Krabbe, Simon; Østergaard, Mikkel; Eshed, Iris

    2018-01-01

    Objective. To investigate whether adalimumab (ADA) reduces whole-body (WB-) magnetic resonance imaging (MRI) indices for inflammation in the entheses, peripheral joints, sacroiliac joints, spine, and the entire body in patients with axial spondyloarthritis (axSpA). Methods. An investigator-initia...

  9. Measurement of the whole-body 137Cs in residents around the Chernobyl Nuclear Power Plant

    International Nuclear Information System (INIS)

    Morita, N.; Takamura, N.; Ashizawa, K.; Shimasaki, T.; Yamashita, S.; Okumura, Y.

    2005-01-01

    To understand the current situation of internal radiation exposure in the population around the Chernobyl Nuclear Power Plant (CNPP), we examined the 137 Cs body burden in six residents of Belarus, Ukraine and Russia in 2002 and 2004 using the whole-body counter (WBC) at Nagasaki Univ. (Japan). The data were compared with those of our previous study performed in 1993-1994 using the same method. In 2002 and 2004, peaks of 137 Cs were detected in two residents from Gomel, which was heavily contaminated by the CNPP accident, one from Minsk (Belarus) and one from Kiev (Ukraine), but another resident from Minsk showed no 137 Cs peaks. The results of the present study suggests that residents around the CNPP are still exposed to chronic 137 Cs internal irradiation, probably due to the daily consumption of contaminated domestic foods, but the risk of any disease by the irradiation is quite low. Long-term follow-up of WBC around the CNPP is useful and may contribute to radiation safety regulation together with a reduction of unnecessary radio-phobia for the residents. (authors)

  10. Radioisotope studies utilizing a low level whole body counter and clinical applications of activation analysis. Progress report

    International Nuclear Information System (INIS)

    Brill, A.B.

    1976-01-01

    Design modifications in radioisotope scanners are discussed. Studies on the radiation dose distribution in patients from /sup 90m/Tc-albumin microspheres in the lungs, 59 Fe-citrate, 131 I-hippuran in kidney transplants, and /sup 99m/Tc-pyrophosphates are reported. Data on the levels of fallout 137 Co in normal individuals during 1975, as measured by whole-body counting, are reported. Results of studies on iodine metabolism in patients with hyperthyroidism and with T 3 -thyrotoxicosis during 131 I therapy with activities up to 17 mCi showed that the apparent volumes of distribution for different iodine compounds do not change appreciably during therapy in this dose range. Methods are described for measuring the content of Ca alone and Ca and P in bone tissues by transmission scanning using a 252 Cf neutron source for activation of Ca and P

  11. Human whole body cold adaptation.

    Science.gov (United States)

    Daanen, Hein A M; Van Marken Lichtenbelt, Wouter D

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000 y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations, but also physiological adaptations to cold. Dedicated studies show that repeated whole body exposure of individual volunteers, mainly Caucasians, to severe cold results in reduced cold sensation but no major physiological changes. Repeated cold water immersion seems to slightly reduce metabolic heat production, while repeated exposure to milder cold conditions shows some increase in metabolic heat production, in particular non-shivering thermogenesis. In conclusion, human cold adaptation in the form of increased metabolism and insulation seems to have occurred during recent evolution in populations, but cannot be developed during a lifetime in cold conditions as encountered in temperate and arctic regions. Therefore, we mainly depend on our behavioral skills to live in and survive the cold.

  12. Whole-Body and Hepatic Insulin Resistance in Obese Children

    Science.gov (United States)

    Ibarra-Reynoso, Lorena del Rocío; Pisarchyk, Liudmila; Pérez-Luque, Elva Leticia; Garay-Sevilla, Ma. Eugenia; Malacara, Juan Manuel

    2014-01-01

    Background Insulin resistance may be assessed as whole body or hepatic. Objective To study factors associated with both types of insulin resistance. Methods Cross-sectional study of 182 obese children. Somatometric measurements were registered, and the following three adiposity indexes were compared: BMI, waist-to-height ratio and visceral adiposity. Whole-body insulin resistance was evaluated using HOMA-IR, with 2.5 as the cut-off point. Hepatic insulin resistance was considered for IGFBP-1 level quartiles 1 to 3 (HOMA-IR was negatively associated with IGFBP-1 and positively associated with BMI, triglycerides, leptin and mother's BMI. Girls had increased HOMA-IR. IGFBP-1 was negatively associated with waist-to-height ratio, age, leptin, HOMA-IR and IGF-I. We did not find HOMA-IR or IGFBP-1 associated with fatty liver. Conclusion In school-aged children, BMI is the best metric to predict whole-body insulin resistance, and waist-to-height ratio is the best predictor of hepatic insulin resistance, indicating that central obesity is important for hepatic insulin resistance. The reciprocal negative association of IGFBP-1 and HOMA-IR may represent a strong interaction of the physiological processes of both whole-body and hepatic insulin resistance. PMID:25411786

  13. Development of a Compton suppression whole body counting for small animals

    International Nuclear Information System (INIS)

    Martini, Elaine

    1995-01-01

    The basic operation, design and construction of the plastic scintillator detector is described. In order to increase the sensitivity of this detector, two blocks of plastic scintillator have been assembled to act as a anticompton system. The detectors were produced by polymerisation of styrene monomer with PPO (2,5 diphenyl-oxazole) and POPOP (1,4 bis (-5 phenyl-2- oxazoly)benzene) in proportions of 0.5 and 0.05 respectively. The transparency of this detector was evaluated by excitation of the 241 Am source located directly in the back surface plastic coupled to a photomultiplier. The light attenuation according to the detector thickness has fitted to a two-exponential function: relative height pulse = 0,519 e -0.0016 + 0.481 e -0.02112.x . Four radioactive sources 2 2 Na, 54 Mn, 137 Cs and 131 I were used to evaluate the performance of this system. The Compton reduction factor, determined by the ratio of the energy peak values of suppressed and unsuppressed spectra was 1.16. The Compton suppression factor determined by the ratio of the net photopeak area to the area of an equal spectra width in the Compton continuum, was approximately 1.208 ± 0.109. The sensitivity of the system, defined as the least amount of a radioactivity that can be quantified in the photopeak region, was 9.44 cps. First, the detector was assembled to be applied in biological studies of whole body counter measurements of small animals. Using a phantom, (small animal simulator) and a punctual 137 Cs source, located in the central region of the well counter the geometrical efficiency detector was about 5%. (author)

  14. Between-centre variability versus variability over time in DXA whole body measurements evaluated using a whole body phantom

    Energy Technology Data Exchange (ETDEWEB)

    Louis, Olivia [Department of Radiology, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)]. E-mail: olivia.louis@az.vub.ac.be; Verlinde, Siska [Belgian Study Group for Pediatric Endocrinology (Belgium); Thomas, Muriel [Belgian Study Group for Pediatric Endocrinology (Belgium); De Schepper, Jean [Department of Pediatrics, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)

    2006-06-15

    This study aimed to compare the variability of whole body measurements, using dual energy X-ray absorptiometry (DXA), among geographically distinct centres versus that over time in a given centre. A Hologic-designed 28 kg modular whole body phantom was used, including high density polyethylene, gray polyvinylchloride and aluminium. It was scanned on seven Hologic QDR 4500 DXA devices, located in seven centres and was also repeatedly (n = 18) scanned in the reference centre, over a time span of 5 months. The mean between-centre coefficient of variation (CV) ranged from 2.0 (lean mass) to 5.6% (fat mass) while the mean within-centre CV ranged from 0.3 (total mass) to 4.7% (total area). Between-centre variability compared well with within-centre variability for total area, bone mineral content and bone mineral density, but was significantly higher for fat (p < 0.001), lean (p < 0.005) and total mass (p < 0.001). Our results suggest that, even when using the same device, the between-centre variability remains a matter of concern, particularly where body composition is concerned.

  15. Whole body MR imaging in diabetes

    International Nuclear Information System (INIS)

    Weckbach, Sabine; Schoenberg, Stefan O.

    2009-01-01

    Diabetes mellitus is a major cardiovascular risk factor and one of the major causes for morbidity and mortality worldwide. Diabetic complications have not only major impact on the quality of life of diabetic patients, but are also potentially life-threatening. Therefore prevention, diagnosis and therapy of these long-term complications are of high importance. However, diagnosis of the variety of complications from diabetes mellitus remains a diagnostic challenge and usually several diagnostic steps are necessary to diagnose or exclude these complications. In the last years whole body magnetic resonance imaging (WB-MRI) including whole body magnetic resonance angiography (WB-MRA) has been introduced for cardiovascular imaging and is now increasingly applied in clinical routine for the workup of patients with cardiovascular disease and for cardiovascular screening. The article summarizes rationales for WB-MRI in diabetes mellitus, technical concepts of disease specific cardiovascular WB-MRI in diabetes mellitus and discusses potential clinical consequences.

  16. The radioimmunotoxicological and radiogenotoxicological effect induced by 134Cs retention in the whole body and skeleton and germ system

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Xia Fen; Yang Weidong

    1993-05-01

    A fitted equation to describe the retention of 134 Cs in whole body is obtained by a whole body counter. The equation consists of two half-life components, the fast component is T 1/2 = 0.07 d and the slow component is T 1/2 = 16.14 d. Two fitted equations describing the retention of 134 Cs in skeleton and testes are also introduced. The T 1/2 in skeleton is 5.73 d and in testes is 5.21 d. The results of investigating radioimmunotoxicological effect induced by 134 Cs show that the inhibition of thymus cells is higher than bone marrow cells, the spleen T-lymphocytes is more sensitive to 134 Cs than B-lymphocytes and lymphocytes of peripheral immune organ are more sensitive to radiation than central immune cells and thymus cells. The study of radiogenotoxicological effect induced by 134 Cs shows that the chromosome aberration frequencies and PCE micronucleus formation in bone marrow cells are significantly high, it can induce chromosome aberrations of spermatogonia and increases the abnormality of sperm. The relations between injected dose and abnormalities can be expressed by power functions

  17. Analysis of whole-body vibration on rheological models for tissues

    Science.gov (United States)

    Neamţu, A.; Simoiu, D.; Nyaguly, E.; Crastiu, I.; Bereteu, L.

    2018-01-01

    Whole body vibrations have become a very popular method in recent years, both in physical therapy and in sports. This popularity is due to the fact that, as a result of analyzing the groups of subjects, the effects of small amplitude vibration and low frequency vibration, it was found an increase in the force developed by the feet, a hardening of bone strength or an increase in bone density. In this paper we propose to give a possible explanation of the stress relieving in muscle and/or bone after whole body vibration treatment. To do this we consider some rheological models which after whole body vibrations and after the analysis of their response lead to various experiments.

  18. Whole body vibration improves body mass, flexibility and strength in ...

    African Journals Online (AJOL)

    Objectives. This study aimed to determine the effectiveness of whole body vibration (WBV) training for promoting healthrelated physical fitness in sedentary adults. Design. A non-randomised sampling technique was used with an equivalent match-pair comparison group, pre- and posttest design. Volunteers were gathered ...

  19. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    Science.gov (United States)

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Mosquito bite anaphylaxis: immunotherapy with whole body extracts.

    Science.gov (United States)

    McCormack, D R; Salata, K F; Hershey, J N; Carpenter, G B; Engler, R J

    1995-01-01

    Adverse reactions to mosquito bites have been recognized for some time. These usually consist of large local swellings and redness, generalized urticaria, angioedema and less easily definable responses such as nausea, dizziness, headaches, and lethargy. We report two patients who experienced systemic anaphylaxis from mosquito bites. Both were skin tested and given immunotherapy using whole body mosquito extracts. Skin testing using whole body mosquito extracts was positive to Aedes aegypti at 1/1,000 weight/volume (wt/vol) in one patient and to Aedes aegypti at 1/100,000 wt/vol, and Culex pipiens at 1/10,000 wt/vol in the other. Skin testing of ten volunteers without a history of adverse reactions to mosquito bites was negative. Immunotherapy using these extracts resulted in resolution of adverse reactions to mosquito bites in one patient and a decrease in reactions in the other. Immunotherapy with whole body mosquito extracts is a viable treatment option that can play a role in patients with mosquito bite-induced anaphylaxis. It may also result in severe side effects and one must determine the benefit versus risks for each individual patient.

  1. Whole-body magnetic resonance imaging in children: state of the art

    Directory of Open Access Journals (Sweden)

    Sara Reis Teixeira

    2015-04-01

    Full Text Available Whole-body imaging in children was classically performed with radiography, positron-emission tomography, either combined or not with computed tomography, the latter with the disadvantage of exposure to ionizing radiation. Whole-body magnetic resonance imaging (MRI, in association with the recently developed metabolic and functional techniques such as diffusion-weighted imaging, has brought the advantage of a comprehensive evaluation of pediatric patients without the risks inherent to ionizing radiation usually present in other conventional imaging methods. It is a rapid and sensitive method, particularly in pediatrics, for detecting and monitoring multifocal lesions in the body as a whole. In pediatrics, it is utilized for both oncologic and non-oncologic indications such as screening and diagnosis of tumors in patients with genetic syndromes, evaluation of disease extent and staging, evaluation of therapeutic response and post-therapy follow-up, evaluation of non neoplastic diseases such as multifocal osteomyelitis, vascular malformations and syndromes affecting multiple regions of the body. The present review was aimed at describing the major indications of whole-body MRI in pediatrics added of technical considerations.

  2. Evidence of impaired learning during whole-body vibration

    Science.gov (United States)

    Sherwood, N.; Griffin, M. J.

    1992-01-01

    A study of the effects of whole-body vibration on learning and memory was conducted, in which a context-dependent experimental design was used. Forty subjects completed a simple associative learning task, half during exposure to 16 Hz whole-body sinusoidal vertical vibration at 2.0 m s -2 r.m.s. and half while static. The results show that the rates of learning of the two groups differed, with that of the vibrated subjects significantly impaired. A second session, one week later, indicated that information learnt in one vibration environment could be recalled equally well in a different environment, suggesting no context-dependent effects on memory processes.

  3. A finite-element simulation of galvanic coupling intra-body communication based on the whole human body.

    Science.gov (United States)

    Song, Yong; Zhang, Kai; Hao, Qun; Hu, Lanxin; Wang, Jingwen; Shang, Fuzhou

    2012-10-09

    Simulation based on the finite-element (FE) method plays an important role in the investigation of intra-body communication (IBC). In this paper, a finite-element model of the whole body model used for the IBC simulation is proposed and verified, while the FE simulation of the galvanic coupling IBC with different signal transmission paths has been achieved. Firstly, a novel finite-element method for modeling the whole human body is proposed, and a FE model of the whole human body used for IBC simulation was developed. Secondly, the simulations of the galvanic coupling IBC with the different signal transmission paths were implemented. Finally, the feasibility of the proposed method was verified by using in vivo measurements within the frequency range of 10 kHz-5 MHz, whereby some important conclusions were deduced. Our results indicate that the proposed method will offer significant advantages in the investigation of the galvanic coupling intra-body communication.

  4. Human whole body cold adaptation.

    OpenAIRE

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    ABSTRACT Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000?y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations...

  5. Evaluation of the uncertainties associated to the in vivo monitoring of iodine-131 in the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Gontijo, Rodrigo Modesto Gadelha; Lucena, Eder Augusto; Dantas, Ana Leticia A.; Dantas, Bernardo Maranhao [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The internal dose from the incorporation of radionuclides by humans can be estimated by in vivo direct measurements in the human body and in vitro analysis of biological indicators. In vivo techniques consist on the identification and quantification of radionuclides present in the whole body and in specific organs and tissues. The results obtained in measurements may present small uncertainties which are within pre-set limits in monitoring programs for occupationally exposed individuals. This study aims to evaluate the sources of uncertainty associated with the results of in vivo monitoring of iodine 131 in the thyroid. The benchmarks adopted in this study are based on the criteria suggested by the General Guide for Estimating Effective Doses from Monitoring Data (Project IDEAS/European Community). The reference values used were the ones for high-energy photons (>100 keV). Besides the parameters suggested by the IDEAS Guide, it has also been evaluated the fluctuation of the counting due to the phantom repositioning, which represents the reproducibility of the counting geometry. Measurements were performed at the Whole Body Counter Unit of the IRD using a scintillation detector NaI (Tl) 3'' x 3'' and a neck-thyroid phantom developed at the In Vivo Monitoring Laboratory of IRD. This phantom contains a standard source of barium-133 added to a piece of filter paper with the dimension and shape of a thyroid gland. Scattering factors were calculated and compared in different counting geometries. The results show that the technique studied presents reproducibility equivalent to the values suggested in the IDEAS Guide and measurement uncertainties compatible to international quality standards for this type of in vivo monitoring. (author)

  6. Rifaximin diminishes neutropenia following potentially lethal whole-body radiation.

    Science.gov (United States)

    Jahraus, Christopher D; Schemera, Bettina; Rynders, Patricia; Ramos, Melissa; Powell, Charles; Faircloth, John; Brawner, William R

    2010-07-01

    Terrorist attacks involving radiological or nuclear weapons are a substantial geopolitical concern, given that large populations could be exposed to potentially lethal doses of radiation. Because of this, evaluating potential countermeasures against radiation-induced mortality is critical. Gut microflora are the most common source of systemic infection following exposure to lethal doses of whole-body radiation, suggesting that prophylactic antibiotic therapy may reduce mortality after radiation exposure. The chemical stability, easy administration and favorable tolerability profile of the non-systemic antibiotic, rifaximin, make it an ideal potential candidate for use as a countermeasure. This study evaluated the use of rifaximin as a countermeasure against low-to-intermediate-dose whole-body radiation in rodents. Female Wistar rats (8 weeks old) were irradiated with 550 cGy to the whole body and were evaluated for 30 d. Animals received methylcellulose, neomycin (179 mg/kg/d) or variably dosed rifaximin (150-2000 mg/kg/d) one hour after irradiation and daily throughout the study period. Clinical assessments (e.g. body weight) were made daily. On postirradiation day 30, blood samples were collected and a complete blood cell count was performed. Animals receiving high doses of rifaximin (i.e. 1000 or 2000 mg/kg/d) had a greater increase in weight from the day of irradiation to postirradiation day 30 compared with animals that received placebo or neomycin. For animals with an increase in average body weight from irradiation day within 80-110% of the group average, methylcellulose rendered an absolute neutrophil count (ANC) of 211, neomycin rendered an ANC of 334, rifaximin 300 mg/kg/d rendered an ANC of 582 and rifaximin 1000 mg/kg/d rendered an ANC of 854 (P = 0.05 for group comparison). Exposure to rifaximin after near-lethal whole-body radiation resulted in diminished levels of neutropenia.

  7. Whole-Body MR Imaging Including Angiography: Predicting Recurrent Events in Diabetics.

    Science.gov (United States)

    Bertheau, Robert C; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M; Parhofer, Klaus G; Kauczor, Hans-Ulrich; Schoenberg, Stefan O; Weckbach, Sabine; Schlett, Christopher L

    2016-05-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30%) developed one, 8 (13%) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75%, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63%, p = 0.001), carotid artery stenosis (11/17/63%, p = 0.005), peripheral artery stenosis (26/56/88%, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. • Patients with long-standing diabetes mellitus are at high risk for recurrent events. • Whole-body MRI predicts occurrence of recurrent events independently of clinical characteristics. • The vessel score derived from whole-body angiography is a good general risk-marker. • Whole-body MRI may also provide organ-specific risk assessment. • Current findings may indicate benefits of

  8. Whole Body Magnetic Resonance Imaging in the Diagnosis of Parsonage Turner Syndrome

    International Nuclear Information System (INIS)

    Ryan, M.; Twair, A.; Nelson, E.; Brennan, D.; Eustace, S.

    2004-01-01

    Purpose: To describe magnetic resonance imaging (MRI) findings in patients with suspected Parsonage Turner syndrome and to emphasize the value of an additional whole body MR scan to improve specificity of this diagnosis. Material and Methods: Three patients with proven Parsonage Turner syndrome referred for conventional MRI of the shoulder girdle and additional whole body turboSTIR MRI were included for study. Results: In each case, imaging revealed edema in the muscles of the shoulder girdle. Whole body turboSTIR MRI scan confirmed localized unilateral changes in each case improving specificity and confidence in the diagnosis of Parsonage Turner syndrome in each case. Conclusion: Whole body turboSTIR MR imaging is a useful diagnostic tool in the evaluation of patients with suspected Parsonage Turner syndrome. Inclusion of the brain, neck, brachial plexus, and extremity musculature at whole body imaging allows differentiation from polymyositis and elimination of additional causes of shoulder girdle pain and weakness including gross lesions in the brain, neck, and brachial plexus by a single non-invasive study

  9. Whole-body MRI using a sliding table and repositioning surface coil approach

    International Nuclear Information System (INIS)

    Takahara, Taro; Kwee, Thomas; Luijten, Peter; Kibune, Satoshi; Ochiai, Reiji; Sakamoto, Tetsuro; Niwa, Tetsu; Van Cauteren, Marc

    2010-01-01

    To introduce and assess a new way of performing whole-body magnetic resonance imaging (MRI) using a non-integrated surface coil approach as available on most clinical MRI systems worldwide. Ten consecutive asymptomatic subjects prospectively underwent whole-body MRI for health screening. Whole-body MRI included T1-, T2- and diffusion-weighted sequences, and was performed using a non-integrated surface coil to image four different stations without patient repositioning. The four separately acquired stations were merged, creating seamless coronal whole-body T1-, T2- and diffusion-weighted images. Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations were qualitatively assessed. The average time (±SD) taken to change the surface coil from one station to the next station was 53.8 (±7.1) s. The average total extra examination time ± SD was 2 min 41.4 s (±15.3 s). Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations of T1-, T2- and diffusion-weighted whole-body MRI were overall graded as ''good'' to ''excellent''. This study shows that a time-efficient and high-quality whole-body MRI examination can easily be performed by using a non-integrated sliding surface coil approach. (orig.)

  10. Segmentation and visual analysis of whole-body mouse skeleton microSPECT

    NARCIS (Netherlands)

    Khmelinskii, A.; Groen, H.C.; De Jong, M.; Lelieveldt, B.P.F.

    2012-01-01

    Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality,

  11. Segmentation and Visual Analysis of Whole-Body Mouse Skeleton microSPECT

    NARCIS (Netherlands)

    A. Khmelinskii (Artem); H.C. Groen (Harald); M. Baiker (Martin); M. de Jong (Marion); B.P.F. Lelieveldt (Boudewijn)

    2012-01-01

    textabstractWhole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput,

  12. Comparison of atlas-based techniques for whole-body bone segmentation

    DEFF Research Database (Denmark)

    Arabi, Hossein; Zaidi, Habib

    2017-01-01

    out in terms of estimating bone extraction accuracy from whole-body MRI using standard metrics, such as Dice similarity (DSC) and relative volume difference (RVD) considering bony structures obtained from intensity thresholding of the reference CT images as the ground truth. Considering the Dice....../MRI. To this end, a variety of atlas-based segmentation strategies commonly used in medical image segmentation and pseudo-CT generation were implemented and evaluated in terms of whole-body bone segmentation accuracy. Bone segmentation was performed on 23 whole-body CT/MR image pairs via leave-one-out cross...... validation procedure. The evaluated segmentation techniques include: (i) intensity averaging (IA), (ii) majority voting (MV), (iii) global and (iv) local (voxel-wise) weighting atlas fusion frameworks implemented utilizing normalized mutual information (NMI), normalized cross-correlation (NCC) and mean...

  13. [Modeling of processes of heat transfer in whole-body hyperthermia].

    Science.gov (United States)

    Kinsht, D N

    2006-01-01

    The method of whole-body hyperthermia in which the body temperature for a short time reaches values up to 43-44 degrees C holds currently much promise. However, at body temperatures above 42 degrees C, the risks associated with the hemodynamic instability and the appearance of arrhythmia in the patient increase. A model of heat transfer has been created to increase the efficiency and safety of the immersion-convectional method of whole-body hyperthermia. This model takes into account changes in the skin blood flow and the dynamics of pulse rate depending on body temperature. The model of heat transfer adequately reflects processes of heating of the organism and can form a basis for the calculation of distribution of heat inside the organism.

  14. Whole-body gene expression pattern registration in Platynereis larvae.

    Science.gov (United States)

    Asadulina, Albina; Panzera, Aurora; Verasztó, Csaba; Liebig, Christian; Jékely, Gáspár

    2012-12-03

    Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere) of the Platynereis trochophore larva and used for the detailed study of neuronal development. Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2'-thiodiethanol (TDE), which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP) in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4'6-diamidino-2-phenylindole (DAPI). Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental stage. We then registered to these templates the

  15. Whole-body gene expression pattern registration in Platynereis larvae

    Directory of Open Access Journals (Sweden)

    Asadulina Albina

    2012-12-01

    Full Text Available Abstract Background Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere of the Platynereis trochophore larva and used for the detailed study of neuronal development. Results Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2’-thiodiethanol (TDE, which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4’6-diamidino-2-phenylindole (DAPI. Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental

  16. Whole-Body CT Screening--Should I or Shouldn't I Get One?

    Science.gov (United States)

    ... Procedures Medical Imaging Medical X-ray Imaging Whole-Body CT Screening--Should I or shouldn't I ... What are the risks and benefits of whole-body CT screening? Many people believe incorrectly that a ...

  17. Roadmap evolution: from NTRS to ITRS, from ITRS 2.0 to IRDS

    Science.gov (United States)

    Gargini, Paolo A.

    2017-10-01

    The semiconductor industry benefitted from roadmap guidance since the mid-60s. The roadmap anticipated and outlined the main needs of the semiconductor industry for years to come and identified future challenges and possible solutions. Making transistor smaller by means of advanced lithographic technologies enabled both increased integration levels and improved IC performance. The roadmap methodology allowed the removal of multiple "red brick walls". The NTRS and the ITRS constituted primarily a "bottom up" approach as standard microprocessors and memories where introduced at a blistering pace barely allowing time for system houses to integrate them in their products. The 1998 ITRS provided the vision that triggered research, development and manufacturing communities to develop a completely new transistor structure in addition to replacing aluminum interconnects with a more advanced technology. The advent of Foundries and Fabless companies transformed the electronics industry into a "top down" driven industry in the past 15 years. The ITRS adjusted to this new ecosystem and morphed into the International Roadmap for Devices and Systems (IRDS) sponsored by IEEE. The IRDS is addressing the requirements and needs of the renewed electronics industry. Furthermore, by the middle of the next decade the ability to layout integrated circuits in a 2D geometry grid will reach fundamental physical limits and the aggressive conversion to 3D architecture for integrated circuit must be pursued across the board as an avenue to continuously increasing transistor count and improving performance. EUV technology is finally approaching the manufacturing stage but with the advent of 3D monolithically integrated heterogeneous circuits approaching in the not-toodistant future should the semiconductor industry concentrate its resources on the next lithographic technology generation in order to enhance resolution or on providing a smooth transition to the new revolutionary 3D architecture

  18. Anesthesia and monitoring during whole body radiation in children

    DEFF Research Database (Denmark)

    Henneberg, S; Nilsson, A; Hök, B

    1990-01-01

    During whole body radiation therapy of children, treatment may be done in places not equipped with acceptable scavenging systems for anesthetic gases and where clinical observation of the patient may be impossible. In order to solve this problem, the authors have used a total intravenous (IV) ane....... This anesthetic technique and the stethoscope have been used in seven children. The total IV anesthesia proved to be a useful method for children during whole body radiation. The modified stethoscope functioned very well and was a useful complement to the monitoring equipment....

  19. Anesthesia and monitoring during whole body radiation in children

    DEFF Research Database (Denmark)

    Henneberg, S; Nilsson, A; Hök, B

    1991-01-01

    During whole body radiation therapy of children, treatment may be done in places not equipped with acceptable scavenging systems for anesthetic gases and where clinical observation of the patient may be impossible. In order to solve this problem, the authors have used a total intravenous (IV) ane....... This anesthetic technique and the stethoscope have been used in seven children. The total IV anesthesia proved to be a useful method for children during whole body radiation. The modified stethoscope functioned very well and was a useful complement to the monitoring equipment....

  20. Natural β-carotene and whole body irradiation in rats

    International Nuclear Information System (INIS)

    Ben-Amotz, A.; Rachmilevich, B.; Greenberg, S.; Sela, M.; Weshler, Z.

    1996-01-01

    β-Carotene and other carotenoids are reported to be potent free radical quenchers, singlet oxygen scavengers, and lipid antioxidants. Whole-body irradiation is known to cause an immunosuppression effect in mammals through the possible initiation and production of reactive oxygen species. We decided to test the possible antioxidative effect against whole-body irradiation of a natural β-carotene, composed of equal amounts of the all-trans and 9-cis isomers, obtained from the unicellular alga Dunaliella bardawil. Rats were fed on ground commercial food enriched with natural β-carotene (50 mg/kg diet). On completion of 1 week with β-carotene, the rats were exposed to a single dose of 4 Gy whole-body irradiation, after which their livers and blood were removed for β-carotene and retinol analysis in comparison with control livers of animals irradiated or not, or supplemented with β-carotene after irradiation. A normal increase in body weight with no ill effects was noted in the groups of rats whose diet was supplemented by β-carotene before and after irradiation, compared with the reduction in the specific growth rate in the group of rats irradiated without β-carotene. Liver β-carotene and retinol decreased significantly after irradiation compared with the rats which were not irradiated. This decrease was not shown in rats fed β-carotene prior to irradiation, and the effect of irradiation was partially cured by supplementation with β-carotene after irradiation. High-pressure liquid chromatography (HPLC) analysis of the irradiated animals showed a selective decline in 9-cis β-carotene and in retinol over all-trans β-carotene and retinyl esters. These results suggest that 9-cis β-carotene and retinol protect in vivo against the cellular damage by free radicals induced after whole-body irradiation. (orig.). With 1 fig., 2 tabs

  1. Body-surface contamination monitoring preparatory to monitoring for internal contamination

    International Nuclear Information System (INIS)

    Schlueter, W.; Klucke, H.

    1980-01-01

    Measurements in the whole-body counter of the SAAS are routinely preceded by a thorough inspection of the patients for body-surface contamination to protect the sensitive counting equipment against becoming contaminated and to avoid a falsified indication of incorporated radionuclides. The measuring system employed for these examinations is described. (author)

  2. Improved measurement system for the whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1983-01-01

    A static four-detector system has been established as a whole body radioactivity measurement system. A technique is being developed to position the detectors in such a manner as to minimise longitudinal distribution effects within a subject. This technique, which represents the human body as a simple geometric model, requires the determination of efficiency at any point within this model

  3. FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure

    International Nuclear Information System (INIS)

    Hirata, Akimasa; Asano, Takayuki; Fujiwara, Osamu

    2008-01-01

    The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 deg. C at a whole-body-averaged specific absorption rate of 0.08 W kg -1 , which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface area-to-mass ratio

  4. FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Akimasa; Asano, Takayuki; Fujiwara, Osamu [Department of Computer Science and Engineering, Nagoya Institute of Technology (Japan)], E-mail: ahirata@nitech.ac.jp

    2008-09-21

    The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 deg. C at a whole-body-averaged specific absorption rate of 0.08 W kg{sup -1}, which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface area-to-mass ratio.

  5. FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure.

    Science.gov (United States)

    Hirata, Akimasa; Asano, Takayuki; Fujiwara, Osamu

    2008-09-21

    The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 degrees C at a whole-body-averaged specific absorption rate of 0.08 W kg(-1), which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface area-to-mass ratio.

  6. Whole-body microvascular permeability of small molecules in man

    DEFF Research Database (Denmark)

    Henriksen, J H

    1985-01-01

    In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured by the indica......In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured...

  7. Acute whole-body cooling for exercise-induced hyperthermia: a systematic review.

    Science.gov (United States)

    McDermott, Brendon P; Casa, Douglas J; Ganio, Matthew S; Lopez, Rebecca M; Yeargin, Susan W; Armstrong, Lawrence E; Maresh, Carl M

    2009-01-01

    To assess existing original research addressing the efficiency of whole-body cooling modalities in the treatment of exertional hyperthermia. During April 2007, we searched MEDLINE, EMBASE, Scopus, SportDiscus, CINAHL, and Cochrane Reviews databases as well as ProQuest for theses and dissertations to identify research studies evaluating whole-body cooling treatments without limits. Key words were cooling, cryotherapy, water immersion, cold-water immersion, ice-water immersion, icing, fanning, bath, baths, cooling modality, heat illness, heat illnesses, exertional heatstroke, exertional heat stroke, heat exhaustion, hyperthermia, hyperthermic, hyperpyrexia, exercise, exertion, running, football, military, runners, marathoner, physical activity, marathoning, soccer, and tennis. Two independent reviewers graded each study on the Physiotherapy Evidence Database (PEDro) scale. Seven of 89 research articles met all inclusion criteria and a minimum score of 4 out of 10 on the PEDro scale. After an extensive and critical review of the available research on whole-body cooling for the treatment of exertional hyperthermia, we concluded that ice-water immersion provides the most efficient cooling. Further research comparing whole-body cooling modalities is needed to identify other acceptable means. When ice-water immersion is not possible, continual dousing with water combined with fanning the patient is an alternative method until more advanced cooling means can be used. Until future investigators identify other acceptable whole-body cooling modalities for exercise-induced hyperthermia, ice-water immersion and cold-water immersion are the methods proven to have the fastest cooling rates.

  8. Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI).

    LENUS (Irish Health Repository)

    Gleeson, T G

    2009-03-01

    The aim of the study is to assess the feasibility of whole-body low-dose computed tomography (WBLDCT) in the diagnosis and staging of multiple myeloma and compare to skeletal survey (SS), using bone marrow biopsy and whole-body magnetic resonance imaging (WBMRI; where available) as gold standard.

  9. Whole body detectors for clinical applications

    International Nuclear Information System (INIS)

    Silar, J.

    The requirements are presented on the parameters of whole-body detectors suitable for clinical retention assays and the detector-patient configuration described. A whole-body detector was developed with an axial configuration of two pairs of large-volume scintillation detectors with NaI(Tl) crystals. One pair is placed under the bed, the other above the bed on which the patient is being examined. The axes of the crystals are located at a distance of 90 cm apart. The field of vision of the detector is described for the application of a 137 Cs source in the air and in a 24 cm layer of water. The positive characteristics of the detector are listed as being homogeneous sensitivity, energy resolution, long-term stability of signal pulse amplitude and average pulse rate in the integral mode. The results obtained show that the detector may be used to evaluate the level of contamination of persons by gamma emitters within the region of approximately 800 Bq to 74 MBq. The error in converting the number of signal pulses in the integral mode does not exceed 50% for gamma emitters with a photon energy above 30O keV. (J.B.)

  10. Whole-body irradiation transiently diminishes the adrenocorticotropin response to recombinant human interleukin-1{alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Perlstein, R.S.; Mehta, N.R.; Neta, R.; Whitnall, M.H. [Armed Forces Radiobiology Research Institute, Bethesda, MD (United States); Mougey, E.H. [Walter Reed Army Institute of Research, Washington, DC (United States)

    1995-03-01

    Recombinant human interleukin-1{alpha} (rhIL-1{alpha}) has significant potential as a radioprotector and/or treatment for radiation-induced hematopoietic injury. Both IL-1 and whole-body ionizing irradiation acutely stimulate the hypothalamic-pituitary-adrenal axis. We therefore assessed the interaction of whole-body irradiation and rhIL-1{alpha} in altering the functioning of the axis in mice. Specifically, we determined the adrenocorticotropin (ACTH) and corticosterone responses to rhIL-1{alpha} administered just before and hours to days after whole-body or sham irradiation. Our results indicate that whole-body irradiation does not potentiate the rhIL-1{alpha}-induced increase in ACTH levels at the doses used. In fact, the rhIL-1{alpha}-induced increase in plasma ACTH is transiently impaired when the cytokine is administered 5 h after, but not 1 h before, exposure to whole-body irradiation. The ACTH response may be inhibited by elevated corticosterone levels after whole-body irradiation, or by other radiation-induced effects on the pituitary gland and hypothalamus. 36 refs., 3 figs.

  11. Whole body monitoring of the population of Cambridgeshire

    International Nuclear Information System (INIS)

    Dendy, P.P.; Hayball, M.P.; Lyttle, K.D.

    1992-01-01

    1220 volunteers were monitored using the Addenbrookes wholebody counter and their spectra and results were stored and analysed. Detailed statistical analyses have been made for 1032 volunteers who were Cambridgeshire residents. After tracking the decline of radiocaesium following Chernobyl, figures were established for the maximum likely average level of body contamination of radiocaesium and the practical level of detectability of radioiodine. Other radionuclides were occasionally detected in volunteers but the reason could be readily determined and activities were always low. Results are available in a conveniently recoverable form and the spectra can be examined for the presence of other radionuclides if necessary. (author)

  12. Dynamics of human whole body amino acid metabolism

    International Nuclear Information System (INIS)

    Young, V.R.

    1981-01-01

    The mechanism of regulation of the nitrogen metabolism in humans under various nutritional and physiological states was examined using stable isotopes. In the simultaneous continuous infusion of 1- [ 13 ] - leucine and α- [ 15 N]- lysine, their fluxed decreased when individuals received lower protein intake. The rates of oxidation and incorporation into body proteins of leucine changed in parallel with the protein intake. Such effects of diet on whole body leucine kinetics were modified by the energy state and dietary energy level. The nitrogen balance was also improved by an excess level of dietary energy. When the intake of dietary protein was lowered below the maintenance level, the whole body flux and de novo synthesis of glycine were lowered, but alanine synthesis was clearly increased. The intravenous infusion of glucose at 4 mg/kg.min, which causes increase in excess blood sugar and plasma insulin, increased the alanine flux, but had no effect on the glycine flux. The rate of albumin synthesis, determined by giving 15 N-glycine orally every 3 hr, decreased with the lowered intake of dietary protein in young men, but not in elderly men. This explains why the serum albumin synthesis increases with the increase in the intake of dietary protein in young men, but not in elderly men. The rate of whole body protein synthesis in young men receiving the L-amino acid diets providing with the required intake of specific amino acid was much lower than that in the men receiving the diets providing with generous intake of specific amino acid. Thus the control mechanism to maintain the homeostasis of body nitrogen and amino acids is related in some unknown way to the nutritional requirement of the hosts. (Kaihara, S.)

  13. Use of extremity insulation during whole body hyperthermia to reduce temperature nonuniformity

    International Nuclear Information System (INIS)

    Thrall, D.E.; Page, R.L.

    1987-01-01

    The author previously documented during whole body hyperthermia in dogs using a radiant heating device that temperature at superficial sites, including tibial bone marrow, falls below systemic arterial temperature during the plateau phase of heating. This may be due to direct heat loss to the environment. Sites where temperature is lower than systemic arterial temperature during the plateau phase may become sanctuary sites where tumor deposits are spared because they do not receive the prescribed thermal dose. In an attempt to decrease temperature nonuniformity and increase thermal dose delivered to such superficial sites, extremity insulation has been employed during whole body hyperthermia in dogs. The author measured temperature at cutaneous and subcutaneous sites and within tibial bone marrow in insulated and noninsulated extremities of dogs undergoing whole body hyperthermia in the radiant heating device. The author found that extremity insulation is effective in reducing extremity temperature nonuniformity. Specific results are presented. Extremity insulation may be necessary during whole body hyperthermia to assure that extremity tumor deposits receive a thermal dose similar to that prescribed for the entire body

  14. A high protein diet upregulated whole-body protein turnover during energy deficit

    Science.gov (United States)

    The effects of higher protein diets and sustained energy deficit (ED) on whole-body protein turnover (WBPTO) are not well described. This study examined whether dietary protein level influences whole-body protein breakdown (Ra), non-oxidative leucine disposal (NOLD), and oxidation (Ox) during ED. ...

  15. Late response to whole-lung irradiation alone and with whole-body hyperthermia in dogs

    International Nuclear Information System (INIS)

    Gillette, S.M.; Gillette, E.L.; Dawson, C.A.

    1997-01-01

    The late effects of whole-lung irradiation with and without whole-body hyperthermia were studied in beagle dogs. The reference doses ranged from 18 to 49.5 Gy given in 1.5-Gy fractions over 6 weeks. Whole-body hyperthermia was given in three 2-h treatments to a deep rectal temperature of 42.0 degrees C. Radiation was given simultaneously with hyperthermia on those days. Physiological and histopathological responses were evaluated. Physiological changes included decreases in cardiac output, systemic blood pressure, dynamic compliance and serotonin uptake. Early changes included an increase in extravascular water and total protein in the lavage. These changes were considered mild, were compensated for and occurred only in dogs receiving doses of 40.5 Gy or greater given in 1.5-Gy fractions over 6 weeks. Histopathological change were typical of irradiated lung and included pleural fibrosis, interstitial fibrosis, fibrotic foci, and peribronchial and perivascular fibrosis. There was no enhancement of late injury to lung by hyperthermia seen in this study. 17 refs., 3 figs., 2 tabs

  16. Whole-body counter intercomparison measurements in Hungary and Italy

    Energy Technology Data Exchange (ETDEWEB)

    Andrasi, A. [Atomic Energy Research Institute, Budapest (Hungary). KFKI; Tarroni, G. [ENEA, Centro Ricerche `Ezio Clementel`, Bologna (Italy). Dipt. Ambiente

    1999-01-01

    In the frame of a co-operation agreement between Austrian Research Center Seibersdorf, Italian ENEA Institute for Radiation Protection and Hungarian KFKI Atomic Energy Research Centre, an intercomparison on WBC measurements using a modular bottle phantom was performed during 1995 in Hungary, on May-July 1996 in the Northern part of Italy. Results related to the relative bias for the three body masses are reported, together with indication of their compliance with ANSI report N13.30. It turned out that majority of the results were found to be within the performance criteria of the ANSI report, however there were also few outfalling results which were a good indication to check and improve the reliability of calibration and/or other methodological procedures. In the contrary of the expectance, the results related to 20 kg phantom resulted not significantly worse than those obtained for the adult phantom indicating the capacity for the participating WBC centres of measuring people from the general population. [Italiano] Nell`ambito di un accordo di collaborazione tra il Centro di Ricerca di Seibersdorf (Austria), l`Istituto per la Radioprotezione dell`ENEA (ENEA AMB PRO IRP) ed il Centro di Ricerca per l`Energia Atomica KFKI di Budapest (Ungheria), si e` svolto un interconfronto su misure WBC basato sull`utilizzo di un unico fantoccio modulare a bottiglie cui hanno partecipato centri WBC Ungheresi (1995) ed Italiani (Maggio-Giugno 1996). Nel presente rapporto tecnico vengono presentati i risultati ottenuti ed una loro analisi impostata sui criteri di valutazione recentemente proposti dall`ANSI nel rapporto N. 13.30. Sulla base di tale criterio la maggior parte dei risultati dell`interconfronto rientra nell`intervallo di accettabilita`; nei pochi casi di non accettabilita` si rende invece necessaria una revisione dei dati di calibrazione e delle metodologie. Contrariamente a quanto si poteva prevedere, i risultati relativi al fantoccio da 20 kg appaiono sostanzialmente

  17. Made-to-measure pattern development based on 3D whole body scans

    NARCIS (Netherlands)

    Daanen, H.; Hong, S.A.

    2008-01-01

    Purpose - New techniques are required to link 3D whole body scans to manufacturing techniques to allow for the mass-customization of clothes. This study aims to compare two methods of producing skirts based on 3D whole body scans. Design/methodology/approach - Three females participated in the

  18. Signal Processing Methods for Removing the Effects of Whole Body Vibration upon Speech

    Science.gov (United States)

    Bitner, Rachel M.; Begault, Durand R.

    2014-01-01

    Humans may be exposed to whole-body vibration in environments where clear speech communications are crucial, particularly during the launch phases of space flight and in high-performance aircraft. Prior research has shown that high levels of vibration cause a decrease in speech intelligibility. However, the effects of whole-body vibration upon speech are not well understood, and no attempt has been made to restore speech distorted by whole-body vibration. In this paper, a model for speech under whole-body vibration is proposed and a method to remove its effect is described. The method described reduces the perceptual effects of vibration, yields higher ASR accuracy scores, and may significantly improve intelligibility. Possible applications include incorporation within communication systems to improve radio-communication systems in environments such a spaceflight, aviation, or off-road vehicle operations.

  19. Acute volume expansion preserves orthostatic tolerance during whole-body heat stress in humans.

    Science.gov (United States)

    Keller, David M; Low, David A; Wingo, Jonathan E; Brothers, R Matthew; Hastings, Jeff; Davis, Scott L; Crandall, Craig G

    2009-03-01

    Whole-body heat stress reduces orthostatic tolerance via a yet to be identified mechanism(s). The reduction in central blood volume that accompanies heat stress may contribute to this phenomenon. The purpose of this study was to test the hypothesis that acute volume expansion prior to the application of an orthostatic challenge attenuates heat stress-induced reductions in orthostatic tolerance. In seven normotensive subjects (age, 40 +/- 10 years: mean +/- S.D.), orthostatic tolerance was assessed using graded lower-body negative pressure (LBNP) until the onset of symptoms associated with ensuing syncope. Orthostatic tolerance (expressed in cumulative stress index units, CSI) was determined on each of 3 days, with each day having a unique experimental condition: normothermia, whole-body heating, and whole-body heating + acute volume expansion. For the whole-body heating + acute volume expansion experimental day, dextran 40 was rapidly infused prior to LBNP sufficient to return central venous pressure to pre-heat stress values. Whole-body heat stress alone reduced orthostatic tolerance by approximately 80% compared to normothermia (938 +/- 152 versus 182 +/- 57 CSI; mean +/- S.E.M., P body heating completely ameliorated the heat stress-induced reduction in orthostatic tolerance (1110 +/- 69 CSI, P stress results in many cardiovascular and neural responses that directionally challenge blood pressure regulation, reduced central blood volume appears to be an underlying mechanism responsible for impaired orthostatic tolerance in the heat-stressed human.

  20. Whole-body imaging of the musculoskeletal system: the value of MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Gerwin P.; Reiser, Maximilian F.; Baur-Melnyk, Andrea [University Hospitals Munich/Grosshadern, LMU, Institute of Clinical Radiology, Munich (Germany)

    2007-12-15

    In clinical practice various modalities are used for whole-body imaging of the musculoskeletal system, including radiography, bone scintigraphy, computed tomography, magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET-CT). Multislice CT is far more sensitive than radiographs in the assessment of trabecular and cortical bone destruction and allows for evaluation of fracture risk. The introduction of combined PET-CT scanners has markedly increased diagnostic accuracy for the detection of skeletal metastases compared with PET alone. The unique soft-tissue contrast of MRI enables for precise assessment of bone marrow infiltration and adjacent soft tissue structures so that alterations within the bone marrow may be detected before osseous destruction becomes apparent in CT or metabolic changes occur on bone scintigraphy or PET scan. Improvements in hard- and software, including parallel image acquisition acceleration, have made high resolution whole-body MRI clinically feasible. Whole-body MRI has successfully been applied for bone marrow screening of metastasis and systemic primary bone malignancies, like multiple myeloma. Furthermore, it has recently been proposed for the assessment of systemic bone diseases predisposing for malignancy (e.g., multiple cartilaginous exostoses) and muscle disease (e.g., muscle dystrophy). The following article gives an overview on state-of-the-art whole-body imaging of the musculoskeletal system and highlights present and potential future applications, especially in the field of whole-body MRI. (orig.)

  1. Detection of bone metastasis of prostate cancer. Comparison of whole-body MRI and bone scintigraphy

    International Nuclear Information System (INIS)

    Ketelsen, D.; Roethke, M.; Aschoff, P.; Lichy, M.P.; Claussen, C.D.; Schlemmer, H.P.; Merseburger, A.S.; Reimold, M.

    2008-01-01

    Purpose: prostate cancer continues to be the third leading cancer-related mortality of western men. Early diagnosis of bone metastasis is important for the therapy regime and for assessing the prognosis. The standard method is bone scintigraphy. Whole-body MRI proved to be more sensitive for early detection of skeletal metastasis. However, studies of homogenous tumor entities are not available. The aim of the study was to compare bone scintigraphy and whole-body MRI regarding the detection of bone metastasis of prostate cancer. Materials and methods: 14 patients with histologically confirmed prostate cancer and a bone scintigraphy as well as whole-body MRI within one month were included. The mean age was 68 years. Scintigraphy was performed using the planar whole-body technique (ventral and dorsal projections). Suspect areas were enlarged. Whole-body MRI was conducted using native T1w and STIR sequences in the coronary plane of the whole body, sagittal imaging of spine and breath-hold STIR and T1w-Flash-2D sequences of ribs and chest. Bone scintigraphy and whole-body MRI were evaluated retrospectively by experienced radiologists in a consensus reading on a lesion-based level. Results: whole-body MRI detected significantly more bone metastasis (p = 0.024). 96.4% of the demonstrated skeletal metastases in bone scintigraphy were founded in whole-body MRI while only 58.6% of the depicted metastases in MRI were able to be located in scintigraphy. There was no significant difference regarding bone metastasis greater than one centimeter (p = 0.082) in contrast to metastasis less than one centimeter (p = 0.035). Small osteoblastic metastases showed a considerably higher contrast in T1w sequences than in STIR imaging. Further advantages of whole-body MRI were additional information about extra-osseous tumor infiltration and their complications, for example stenosis of spinal canal or vertebral body fractures, found in 42.9% of patients. (orig.)

  2. Direct molecular analysis of whole-body animal tissue sections by MALDI imaging mass spectrometry.

    Science.gov (United States)

    Reyzer, Michelle L; Chaurand, Pierre; Angel, Peggi M; Caprioli, Richard M

    2010-01-01

    The determination of the localization of various compounds in a whole animal is valuable for many applications, including pharmaceutical absorption, distribution, metabolism, and excretion (ADME) studies and biomarker discovery. Imaging mass spectrometry is a powerful tool for localizing compounds of biological interest with molecular specificity and relatively high resolution. Utilizing imaging mass spectrometry for whole-body animal sections offers considerable analytical advantages compared to traditional methods, such as whole-body autoradiography, but the experiment is not straightforward. This chapter addresses the advantages and unique challenges that the application of imaging mass spectrometry to whole-body animal sections entails, including discussions of sample preparation, matrix application, signal normalization, and image generation. Lipid and protein images obtained from whole-body tissue sections of mouse pups are presented along with detailed protocols for the experiments.

  3. 2nd Tuebingen radiotherapy symposium: Whole body, large field and whole skin irradiation. Introduction

    International Nuclear Information System (INIS)

    Huebener, K.H.; Frommhold, W.

    1987-01-01

    The symposium which took place on the 11th and 12th April 1986 set itself the task of discussing three different groups of radiotherapy topics. The chief issue was whole-body irradiation prior to bone marrow transplants, in which all the therapy centres in West Germany, Austria, East Germany and German-speaking Switzerland made clinical and radiophysical contributions. The second part of the Symposium consisted mainly of talks and discussions on large-field irradiation, more precisely half-body and sequential partial body irradiation. This topic was chosen because this type of therapy is scarcely practised at all, particularly in West Germany, whereas in the United States, East Germany, Switzerland and a number of other countries it has long since become one of the established methods. The last talk at the Symposium explained clinical and radiophysical aspects of whole-skin irradiation. Here too, one was impressed by the wide diversity of the equipment and methods of irradiation used which, nevertheless, all demonstrated satisfactory practical solutions in their common aim of distributing the dose as homogeneously as possible. (orig./MG) [de

  4. Statistical multi-path exposure method for assessing the whole-body SAR in a heterogeneous human body model in a realistic environment.

    Science.gov (United States)

    Vermeeren, Günter; Joseph, Wout; Martens, Luc

    2013-04-01

    Assessing the whole-body absorption in a human in a realistic environment requires a statistical approach covering all possible exposure situations. This article describes the development of a statistical multi-path exposure method for heterogeneous realistic human body models. The method is applied for the 6-year-old Virtual Family boy (VFB) exposed to the GSM downlink at 950 MHz. It is shown that the whole-body SAR does not differ significantly over the different environments at an operating frequency of 950 MHz. Furthermore, the whole-body SAR in the VFB for multi-path exposure exceeds the whole-body SAR for worst-case single-incident plane wave exposure by 3.6%. Moreover, the ICNIRP reference levels are not conservative with the basic restrictions in 0.3% of the exposure samples for the VFB at the GSM downlink of 950 MHz. The homogeneous spheroid with the dielectric properties of the head suggested by the IEC underestimates the absorption compared to realistic human body models. Moreover, the variation in the whole-body SAR for realistic human body models is larger than for homogeneous spheroid models. This is mainly due to the heterogeneity of the tissues and the irregular shape of the realistic human body model compared to homogeneous spheroid human body models. Copyright © 2012 Wiley Periodicals, Inc.

  5. Whole spine MRI in the assessment of acute vertebral body trauma

    International Nuclear Information System (INIS)

    Green, R.A.R.; Saifuddin, A.

    2004-01-01

    To determine the incidence and types of multilevel vertebral body injury in association with acute spinal trauma as assessed by whole spine MRI. All acute admissions to a regional spinal injury unit had whole spine MRI carried out, to detect occult vertebral body injury. Two radiologists assessed 127 cases prospectively, over a period of 3 years. All cases had T2-weighted sagittal imaging of the whole spine (where possible using a T2-weighted fat-suppressed sequence), with T1-weighted imaging in both sagittal and axial planes covering the primary injury. The incidence of secondary injury (defined as either bone bruising, wedge compression fracture or burst fracture) was determined and defined by type, site and relationship to the primary injury. Seventy-seven per cent of cases had a secondary injury level. Of these, bone bruising was the commonest but often occurred in combination with secondary wedge compression fracture or burst fracture. MRI detected 27 non-contiguous wedge compression fractures and 16 non-contiguous burst fractures, giving an incidence of secondary level, non-contiguous fracture of approximately 34%. A higher frequency of secondary vertebral body injury may be defined by MRI than has been described in previous studies based on radiographic evaluation of the whole spine. Whole spine MRI in assessment for occult vertebral body fracture enables increased confidence in the conservative or surgical management of patients with severe spinal injury. (orig.)

  6. Dose evaluation based on {sup 24}Na activity in the human body at the JCO criticality accident in Tokai-mura

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Takumaro; Tsujimura, Norio; Tasaki, Takashi; Kanai, Katsuta; Kurihara, Osamu; Hayashi, Naomi; Shinohara, Kunihiko [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan). Tokai Works

    2001-09-01

    {sup 24}Na in the human body, activated by neutrons emitted at the JCO criticality accident, was observed for 62 subjects, where 148 subjects were measured by the whole body counter of JNC Tokai Works. The 148 subjects, including JCO employees and the contractors, residents neighboring the site and emergency service officers, were measured by the whole-body counter. The neutron-energy spectrum around the facility was calculated using neutron transport codes (ANISN and MCNP), and the relation between an amount of activated sodium in human body and neutron dose was evaluated from the calculated neutron energy spectrum and theoretical neutron capture probability by the human body. The maximum {sup 24}Na activity in the body was 7.7 kBq (83 Bq({sup 24}Na)/g({sup 23}Na)) and the relevant effective dose equivalent was 47 mSv. (author)

  7. Whole-body vibration exercise in postmenopausal osteoporosis

    Directory of Open Access Journals (Sweden)

    Magdalena Weber-Rajek

    2015-01-01

    Full Text Available The report of the World Health Organization (WHO of 2008 defines osteoporosis as a disease characterized by low bone mass and an increased risk of fracture. Postmenopausal osteoporosis is connected to the decrease in estrogens concentration as a result of malfunction of endocrine ovarian function. Low estrogens concentration causes increase in bone demineralization and results in osteoporosis. Physical activity, as a component of therapy of patients with osteoporosis, has been used for a long time now. One of the forms of safe physical activity is the vibration training. Training is to maintain a static position or execution of specific exercises involving the appropriate muscles on a vibrating platform, the mechanical vibrations are transmitted to the body of the patient. According to the piezoelectric theory, pressure induces bone formation in the electrical potential difference, which acts as a stimulant of the process of bone formation. Whole body vibration increases the level of growth hormone and testosterone in serum, preventing sarcopenia and osteoporosis. The aim of this study was to review the literature on vibration exercise in patients with postmenopausal osteoporosis based on the PubMed and Medline database. While searching the database, the following key words were used ‘postmenopausal osteoporosis’ and ‘whole-body vibration exercise’.

  8. Prolonged bed rest decreases skeletal muscle and whole body protein synthesis

    Science.gov (United States)

    Ferrando, A. A.; Lane, H. W.; Stuart, C. A.; Davis-Street, J.; Wolfe, R. R.

    1996-01-01

    We sought to determine the extent to which the loss of lean body mass and nitrogen during inactivity was due to alterations in skeletal muscle protein metabolism. Six male subjects were studied during 7 days of diet stabilization and after 14 days of stimulated microgravity (-6 degrees bed rest). Nitrogen balance became more negative (P protein synthesis (PS; P protein also decreased by 46% (P protein breakdown and inward transport. Whole body protein synthesis determined by [15N]alanine ingestion on six subjects also revealed a 14% decrease (P protein breakdown change significantly. These results indicate that the loss of body protein with inactivity is predominantly due to a decrease in muscle PS and that this decrease is reflected in both whole body and skeletal muscle measures.

  9. Circumference estimation using 3D-whole body scanners and shadow scanner

    NARCIS (Netherlands)

    Daanen, H.A.M.

    1998-01-01

    Clothing designers and manufacturers use traditional body dimensions as their basis. When 3D-whole body scanners are introduced to determine the body dimensions, a conversion has to be made, since scan determined circumference measures are slightly larger than the traditional values. This pilot

  10. Polyarteritis nodosa: MDCT as a 'One-Stop Shop' Modality for Whole-Body Arterial Evaluation

    International Nuclear Information System (INIS)

    Tsai, W.-L.; Tsai, I-C.; Lee Tain; Hsieh, C.-W.

    2008-01-01

    Polyarteritis nodosa is a rare disease, which is characterized by aneurysm formation and occlusion in the arteries of multiple systems. Due to its extensive involvement, whole-body evaluation is necessary for diagnosis and treatment monitoring. We report a case of polyarteritis nodosa using multidetector-row computed tomography (MDCT) as a 'one-stop shop' modality for whole-body arterial evaluation. With precise protocol design, MDCT can be used as a reliable noninvasive modality providing comprehensive whole-body arterial evaluation.

  11. The contribution of the body and motion to whole person recognition.

    Science.gov (United States)

    Simhi, Noa; Yovel, Galit

    2016-05-01

    While the importance of faces in person recognition has been the subject of many studies, there are relatively few studies examining recognition of the whole person in motion even though this most closely resembles daily experience. Most studies examining the whole body in motion use point light displays, which have many advantages but are impoverished and unnatural compared to real life. To determine which factors are used when recognizing the whole person in motion we conducted two experiments using naturalistic videos. In Experiment 1 we used a matching task in which the first stimulus in each pair could either be a video or multiple still images from a video of the full body. The second stimulus, on which person recognition was performed, could be an image of either the full body or face alone. We found that the body contributed to person recognition beyond the face, but only after exposure to motion. Since person recognition was performed on still images, the contribution of motion to person recognition was mediated by form-from-motion processes. To assess whether dynamic identity signatures may also contribute to person recognition, in Experiment 2 we presented people in motion and examined person recognition from videos compared to still images. Results show that dynamic identity signatures did not contribute to person recognition beyond form-from-motion processes. We conclude that the face, body and form-from-motion processes all appear to play a role in unfamiliar person recognition, suggesting the importance of considering the whole body and motion when examining person perception. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Correlation of total body potassium and leukemic cell mass in patients with chronic lymphocytic leukemia

    International Nuclear Information System (INIS)

    Chandra, P.; Sawitsky, A.; Chanana, A.D.; Chikkappa, G.; Cohn, S.H.; Rai, K.R.; Cronkity, E.P.

    1979-01-01

    Total body leukemic mass in patients with chronic lymphocytic leukemia (CLL) was measured by quantitation of total body potassium (TBK) with a whole-body counter. In addition, the predicted normal total body potassium (Kp) for each patient was calculated from an empirically derived relationship involving height, weight age, and sex. Both the absolute TBK and the relative excess of total body potassium (TBK/Kp) were related to the stage of disease. Patients in the early stages of CLL were found to have lower TBK and TBK/Kp than patients in the late stages of disease. Both of these parameters increased with the successively advanced stages of the disease. The clinically monitored reduction of leukemic cell mass following therapy was accompanied by reductions in TBK and TBK/Kp. Data presented support the notion that TBK/Kp is a useful indicator of the total body leukemic mass. Futhermore, the results of these studies quantitatively validate the proposed clinical staging system for CLL. Quantitation of TBK by a whole-body counter is an accurate and noninvasive procedure and does not require administration of isotopes

  13. Producing 'internal suspect bodies': divisive effects of UK counter-terrorism measures on Muslim communities in Leeds and Bradford.

    Science.gov (United States)

    Abbas, Madeline-Sophie

    2018-04-06

    Research on UK government counter-terrorism measures has claimed that Muslims are treated as a 'suspect community'. However, there is limited research exploring the divisive effects that membership of a 'suspect community' has on relations within Muslim communities. Drawing from interviews with British Muslims living in Leeds or Bradford, I address this gap by explicating how co-option of Muslim community members to counter extremism fractures relations within Muslim communities. I reveal how community members internalize fears of state targeting which precipitates internal disciplinary measures. I contribute the category of 'internal suspect body' which is materialized through two intersecting conditions within preventative counter-terrorism: the suspected extremist for Muslims to look out for and suspected informer who might report fellow Muslims. I argue that the suspect community operates through a network of relations by which terrors of counter-terrorism are reproduced within Muslim communities with divisive effects. © London School of Economics and Political Science 2018.

  14. A new method of body habitus correction for total body potassium measurements

    International Nuclear Information System (INIS)

    O'Hehir, S; Green, S; Beddoe, A H

    2006-01-01

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use

  15. A new method of body habitus correction for total body potassium measurements

    Energy Technology Data Exchange (ETDEWEB)

    O' Hehir, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Green, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Beddoe, A H [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom)

    2006-09-07

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use.

  16. Whole body acid-base modeling revisited.

    Science.gov (United States)

    Ring, Troels; Nielsen, Søren

    2017-04-01

    The textbook account of whole body acid-base balance in terms of endogenous acid production, renal net acid excretion, and gastrointestinal alkali absorption, which is the only comprehensive model around, has never been applied in clinical practice or been formally validated. To improve understanding of acid-base modeling, we managed to write up this conventional model as an expression solely on urine chemistry. Renal net acid excretion and endogenous acid production were already formulated in terms of urine chemistry, and we could from the literature also see gastrointestinal alkali absorption in terms of urine excretions. With a few assumptions it was possible to see that this expression of net acid balance was arithmetically identical to minus urine charge, whereby under the development of acidosis, urine was predicted to acquire a net negative charge. The literature already mentions unexplained negative urine charges so we scrutinized a series of seminal papers and confirmed empirically the theoretical prediction that observed urine charge did acquire negative charge as acidosis developed. Hence, we can conclude that the conventional model is problematic since it predicts what is physiologically impossible. Therefore, we need a new model for whole body acid-base balance, which does not have impossible implications. Furthermore, new experimental studies are needed to account for charge imbalance in urine under development of acidosis. Copyright © 2017 the American Physiological Society.

  17. Whole-body angular momentum during stair ascent and descent.

    Science.gov (United States)

    Silverman, Anne K; Neptune, Richard R; Sinitski, Emily H; Wilken, Jason M

    2014-04-01

    The generation of whole-body angular momentum is essential in many locomotor tasks and must be regulated in order to maintain dynamic balance. However, angular momentum has not been investigated during stair walking, which is an activity that presents a biomechanical challenge for balance-impaired populations. We investigated three-dimensional whole-body angular momentum during stair ascent and descent and compared it to level walking. Three-dimensional body-segment kinematic and ground reaction force (GRF) data were collected from 30 healthy subjects. Angular momentum was calculated using a 13-segment whole-body model. GRFs, external moment arms and net joint moments were used to interpret the angular momentum results. The range of frontal plane angular momentum was greater for stair ascent relative to level walking. In the transverse and sagittal planes, the range of angular momentum was smaller in stair ascent and descent relative to level walking. Significant differences were also found in the ground reaction forces, external moment arms and net joint moments. The sagittal plane angular momentum results suggest that individuals alter angular momentum to effectively counteract potential trips during stair ascent, and reduce the range of angular momentum to avoid falling forward during stair descent. Further, significant differences in joint moments suggest potential neuromuscular mechanisms that account for the differences in angular momentum between walking conditions. These results provide a baseline for comparison to impaired populations that have difficulty maintaining dynamic balance, particularly during stair ascent and descent. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. The A.E.E. Winfrith Whole Body Monitor

    International Nuclear Information System (INIS)

    Peabody, C.O.; Fraser, V.M.; Speight, R.G.

    1962-10-01

    The function, design and construction of the A.E.E. Winfrith Whole Body Monitor are described. The main purpose of the monitor is to measure gamma emitting radioisotopes in the human body. Its performance, capabilities and limitations are discussed and a summary is given of experience gained and results obtained during the first few months of operation. The future programme of measurements and development is outlined. Some basic design criteria are put forward as a result of the experience and results obtained. (author)

  19. Isolation of monocytes from whole blood-derived buffy coats by continuous counter-flow elutriation.

    Science.gov (United States)

    Schwanke, Uwe; Nabereit, Anja; Moog, Rainer

    2006-10-01

    Monocytes (MOs) are the most commonly used precursors for the generation of dendritic cells (DCs) in vitro. Continuous counter-flow elutriation represents a promising tool to isolate MOs from white blood cell (WBC) products. Thirty whole blood-derived, AB0-identical buffy coats (BCs) were pooled using sterile technique (n = 5 experiments). For red blood cell (RBC) and polymorphonuclear cell (PMN) depletion, the BC pools were processed in a Cobe Spectra device (Gambro BCT) using the bone marrow program. Subsequently, continuous counter-flow elutriation in an Elutra device (Gambro BCT) was performed to enrich and purify MOs. BC pool volume averaged 1,260 +/- 14 ml containing 7.7 +/- 1.1 x 10(9) MOs. During 107 +/- 7 min, Cobe Spectra operation, the BC pools were processed for several times, and approximately 9,749 +/- 605 ml volume passed the device. Product volume and MO yield averaged 160 +/- 16 ml, and 4.3 +/- 1.3 x 10(9) cells, respectively. Elutra operation was performed within 59 +/- 0 min and yielded 2.5 +/- 0.9 x 10(9) MOs with a purity of 60 +/- 12%. Compared with the Cobe Spectra product cell count, MO recovery by Elutra averaged 59 +/- 10%. Elutriation of MOs from pooled BCs using Elutra exhibited comparatively low recovery and purity rates. This shortcoming may be due to the nature of the source material. Optimization of the elutriation procedure is necessary to improve MO enrichment from BCs.

  20. Whole body autoradiography with mice using 14C-thymidine

    International Nuclear Information System (INIS)

    Hruby, R. et al

    1982-06-01

    Whole body autoradiography was performed using common histology equipment. Results were useful with some restrictions. 14C-thymidine and/or itsmetabolites were found in those tissues with high rate of mitosis. (Author)

  1. Stability of Phase Relationships While Coordinating Arm Reaches with Whole Body Motion.

    Directory of Open Access Journals (Sweden)

    Romy S Bakker

    Full Text Available The human movement repertoire is characterized by the smooth coordination of several body parts, including arm movements and whole body motion. The neural control of this coordination is quite complex because the various body parts have their own kinematic and dynamic properties. Behavioral inferences about the neural solution to the coordination problem could be obtained by examining the emerging phase relationship and its stability. Here, we studied the phase relationships that characterize the coordination of arm-reaching movements with passively-induced whole-body motion. Participants were laterally translated using a vestibular chair that oscillated at a fixed frequency of 0.83 Hz. They were instructed to reach between two targets that were aligned either parallel or orthogonal to the whole body motion. During the first cycles of body motion, a metronome entrained either an in-phase or an anti-phase relationship between hand and body motion, which was released at later cycles to test phase stability. Results suggest that inertial forces play an important role when coordinating reaches with cyclic whole-body motion. For parallel reaches, we found a stable in-phase and an unstable anti-phase relationship. When the latter was imposed, it readily transitioned or drifted back toward an in-phase relationship at cycles without metronomic entrainment. For orthogonal reaches, we did not find a clear difference in stability between in-phase and anti-phase relationships. Computer simulations further show that cost models that minimize energy expenditure (i.e. net torques or endpoint variance of the reach cannot fully explain the observed coordination patterns. We discuss how predictive control and impedance control processes could be considered important mechanisms underlying the rhythmic coordination of arm reaches and body motion.

  2. Integrating Cellular Metabolism into a Multiscale Whole-Body Model

    Science.gov (United States)

    Krauss, Markus; Schaller, Stephan; Borchers, Steffen; Findeisen, Rolf; Lippert, Jörg; Kuepfer, Lars

    2012-01-01

    Cellular metabolism continuously processes an enormous range of external compounds into endogenous metabolites and is as such a key element in human physiology. The multifaceted physiological role of the metabolic network fulfilling the catalytic conversions can only be fully understood from a whole-body perspective where the causal interplay of the metabolic states of individual cells, the surrounding tissue and the whole organism are simultaneously considered. We here present an approach relying on dynamic flux balance analysis that allows the integration of metabolic networks at the cellular scale into standardized physiologically-based pharmacokinetic models at the whole-body level. To evaluate our approach we integrated a genome-scale network reconstruction of a human hepatocyte into the liver tissue of a physiologically-based pharmacokinetic model of a human adult. The resulting multiscale model was used to investigate hyperuricemia therapy, ammonia detoxification and paracetamol-induced toxication at a systems level. The specific models simultaneously integrate multiple layers of biological organization and offer mechanistic insights into pathology and medication. The approach presented may in future support a mechanistic understanding in diagnostics and drug development. PMID:23133351

  3. Exercise Enhances Whole-Body Cholesterol Turnover in Mice

    NARCIS (Netherlands)

    Meissner, Maxi; Havinga, Rick; Boverhof, Renze; Kema, Ido; Groen, Albert K.; Kuipers, Folkert

    MEISSNER, M., R. HAVINGA, R. BOVERHOF, I. KEMA, A. K. GROEN, and F. KUIPERS. Exercise Enhances Whole-Body Cholesterol Turnover in Mice. Med. Sci. Sports Exerc., Vol. 42, No. 8, pp. 1460-1468, 2010. Purpose: Regular exercise reduces cardiovascular risk in humans by reducing cholesterol levels, but

  4. Whole body autoradiography, ch. 13

    International Nuclear Information System (INIS)

    Jonkman, J.H.G.

    1977-01-01

    The distribution of 35 S-ringlabelled thiazinamium methylsulphate has been studied by means of whole body autoradiography in a squirrel and in mice. Accumulation of activity was found in liver, kidney and intestines (the excretion of pathways). High concentrations were also found in organs with high amount of acetylcholine receptors and in the glandular tissue. No radioactivity was seen in the central nervous system, indicating no passage through the 'blood-brain barrier'. This is the most significant difference with its tertiary analogue Prometharine hydrochloride. In pregnant mice, high concentrations were found in the placenta but only low amounts were found in liver and kidneys of the foetuses

  5. Conjugate whole-body scanning system for quantitative measurement of organ distribution in vivo

    International Nuclear Information System (INIS)

    Tsui, B.M.W.; Chen, C.T.; Yasillo, N.J.; Ortega, C.J.; Charleston, D.B.; Lathrop, K.A.

    1979-01-01

    The determination of accurate, quantitative, biokinetic distribution of an internally dispersed radionuclide in humans is important in making realistic radiation absorbed dose estimates, studying biochemical transformations in health and disease, and developing clinical procedures indicative of abnormal functions. In order to collect these data, a whole-body imaging system is required which provides both adequate spatial resolution and some means of absolute quantitation. Based on these considerations, a new whole-body scanning system has been designed and constructed that employs the conjugate counting technique. The conjugate whole-body scanning system provides an efficient and accurate means of collecting absolute quantitative organ distribution data of radioactivity in vivo

  6. Nasal reaction to changes in whole body temperature.

    Science.gov (United States)

    Lundqvist, G R; Pedersen, O F; Hilberg, O; Nielsen, B

    1993-11-01

    The changes in nasal patency following a 1.5 degrees C decrease or increase in whole body temperature were measured in 8 healthy young males, during and after 30 min of immersion in a 15 degrees C cold or a 40 degrees C warm bath, breathing air at the same temperature, in a cross-over experimental design. The nasal reactions were traced by consecutive measurements of changes in nasal cavity volumes by acoustic rhinometry. Swelling of the mucosa during cooling and an almost maximal shrinkage of the mucosa during heating were indicated by respectively a decrease and an increase in nasal cavity volumes. The reactions were determined predominantly by the whole body thermal balance, but were also influenced by the temperature of the inhaled air, either enhanced, reduced or temporarily reversed. The greatest change occurred in the nasal cavity, left or right, which differed most from the final state at the beginning of exposure due to the actual state of nasal cycle.

  7. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji, E-mail: rush@nirs.go.j [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan)

    2010-09-21

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  8. Antihysteresis of perceived longitudinal body axis during continuous quasi-static whole-body rotation in the earth-vertical roll plane.

    Science.gov (United States)

    Tatalias, M; Bockisch, C J; Bertolini, G; Straumann, D; Palla, A

    2011-03-01

    Estimation of subjective whole-body tilt in stationary roll positions after rapid rotations shows hysteresis. We asked whether this phenomenon is also present during continuous quasi-static whole-body rotation and whether gravitational cues are a major contributing factor. Using a motorized turntable, 8 healthy subjects were rotated continuously about the earth-horizontal naso-occipital axis (earth-vertical roll plane) and the earth-vertical naso-occipital axis (earth-horizontal roll plane). In both planes, three full constant velocity rotations (2°/s) were completed in clockwise and counterclockwise directions (acceleration = 0.05°/s(2), velocity plateau reached after 40 s). Subjects adjusted a visual line along the perceived longitudinal body axis (pLBA) every 2 s. pLBA deviation from the longitudinal body axis was plotted as a function of whole-body roll position, and a sine function was fitted. At identical whole-body earth-vertical roll plane positions, pLBA differed depending on whether the position was reached by a rotation from upright or by passing through upside down. After the first 360° rotation, pLBA at upright whole-body position deviated significantly in the direction of rotation relative to pLBA prior to rotation initiation. This deviation remained unchanged after subsequent full rotations. In contrast, earth-horizontal roll plane rotations resulted in similar pLBA before and after each rotation cycle. We conclude that the deviation of pLBA in the direction of rotation during quasi-static earth-vertical roll plane rotations reflects static antihysteresis and might be a consequence of the known static hysteresis of ocular counterroll: a visual line that is perceived that earth-vertical is expected to be antihysteretic, if ocular torsion is hysteretic.

  9. The influence of dietary and whole-body nutrient content on the excretion of a vertebrate consumer.

    Directory of Open Access Journals (Sweden)

    Christopher M Dalton

    Full Text Available In many contexts, nutrient excretion by consumers can impact ecosystems by altering the availability of limiting nutrients. Variation in nutrient excretion can be predicted by mass balance models, most of which are premised on two key ideas: (1 consumers maintain fixed whole-body nutrient content (i.e., %N and %P, so-called fixed homeostasis; (2 if dietary nutrients are not matched to whole-body nutrients, excesses of any nutrient are released as excretion to maintain fixed homeostasis. Mass balance models thus predict that consumer excretion should be positively correlated with diet nutrients and negatively correlated with whole-body nutrients. Recent meta-analyses and field studies, however, have often failed to find these expected patterns, potentially because of a confounding influence-flexibility in whole-body nutrient content with diet quality (flexible homeostasis. Here, we explore the impact of flexible homeostasis on nutrient excretion by comparing the N and P excretion of four genetically diverged Trinidadian guppy (Poecilia reticulata populations when reared on diets of variable P content. As predicted by mass balance, P excretion increased on the high-P diet, but, contrary to the notion of fixed homeostasis, guppy whole-body %P also increased on the high-P diet. While there was no overall correlation between excretion nutrients and whole-body nutrients, when the effect of diet on both whole-body and excretion nutrients was included, we detected the expected negative correlation between whole-body N:P and excretion N:P. This last result suggests that mass balance can predict excretion rates within species, but only if dietary effects on whole-body nutrient content are controlled. Flexible homeostasis can obscure patterns predicted by mass balance, creating an imperative to accurately capture an organism's diet quality in predicting its excretion rate.

  10. Whole-body magnetic resonance imaging in inflammatory arthritis

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Eshed, Iris; Althoff, Christian E.

    2017-01-01

    Objective: Whole-body magnetic resonance imaging (WB-MRI) is a relatively new technique that can enable assessment of the overall inflammatory status of people with arthritis, but standards for image acquisition, definitions of key pathologies, and a quantification system are required. Our aim...... was to perform a systematic literature review (SLR) and to develop consensus definitions of key pathologies, anatomical locations for assessment, a set of MRI sequences and imaging planes for the different body regions, and a preliminary scoring system for WB-MRI in inflammatory arthritis. Methods: An SLR...

  11. Segmentation and visual analysis of whole-body mouse skeleton microSPECT.

    Directory of Open Access Journals (Sweden)

    Artem Khmelinskii

    Full Text Available Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability. The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers (99mTc-methylene diphosphonate ((99mTc-MDP and (99mTc-hydroxymethane diphosphonate ((99mTc-HDP were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for "incomplete" data (large chunks of skeleton missing and for an intuitive exploration and comparison of multi-modal SPECT

  12. Dose evaluation on the basis of 24Na activity in the human body for the criticality accident at JCO Tokai nuclear fuel processing plant

    International Nuclear Information System (INIS)

    Momose, T.; Tsujimura, N.; Tasaki, T.; Kanai, K.; Hayashi, N.; Shinohara, K.

    2001-01-01

    24 Na in the human body, activated by neutrons emitted at the JCO criticality accident, was observed for 62 subjects, where 148 subjects were measured by the whole body counter of JNC Tokai Works. The 148 subjects, including JCO employees and the contractors, residents neighboring the site and emergency service officers, were measured by the whole-body counter. The neutron-energy spectrum around the facility was calculated using neutron transport codes (ANISN and MCNP), and the relation between an amount of activated sodium in human body and neutron dose was evaluated from the calculated neutron energy spectrum and theoretical neutron capture probability by the human body. The maximum 24 Na activity in the body was 7.7 kBq (83 Bq( 24 Na)/g( 23 Na)) and the relevant effective dose equivalent was 47 mSv. (author)

  13. Integrating cellular metabolism into a multiscale whole-body model.

    Directory of Open Access Journals (Sweden)

    Markus Krauss

    Full Text Available Cellular metabolism continuously processes an enormous range of external compounds into endogenous metabolites and is as such a key element in human physiology. The multifaceted physiological role of the metabolic network fulfilling the catalytic conversions can only be fully understood from a whole-body perspective where the causal interplay of the metabolic states of individual cells, the surrounding tissue and the whole organism are simultaneously considered. We here present an approach relying on dynamic flux balance analysis that allows the integration of metabolic networks at the cellular scale into standardized physiologically-based pharmacokinetic models at the whole-body level. To evaluate our approach we integrated a genome-scale network reconstruction of a human hepatocyte into the liver tissue of a physiologically-based pharmacokinetic model of a human adult. The resulting multiscale model was used to investigate hyperuricemia therapy, ammonia detoxification and paracetamol-induced toxication at a systems level. The specific models simultaneously integrate multiple layers of biological organization and offer mechanistic insights into pathology and medication. The approach presented may in future support a mechanistic understanding in diagnostics and drug development.

  14. Comparison of whole body MR diffusion weighted imaging and skeletal scintigraphy in detecting bone metastasis

    International Nuclear Information System (INIS)

    Xu Xian; Ma Lin; Zhang Jinshan; Cai Youquan; Cheng Liuquan; Guo Xinggao; Xu Baixuan

    2008-01-01

    Objective: To evaluate the application of whole body MR diffusion weighted imaging (DWI) in the detection of bone metastasis using skeletal scintigraphy as the reference. Methods: Forty-two healthy volunteers and 38 patients with malignant tumors were enrolled in our study. All the patients received MR examination and skeletal scintigraphy within one week. MR examination was performed on GE signa 3.0T MR scanner using a build-in body coil. The skeletal system was divided into eight regions and the images of the whole body MR DWI and skeletal scintigraphy were reviewed to compare the two modalities patient by patient and region by region. The images were reviewed separately by two radiologists and two nuclear medicine physicians, who were blinded to the results of another imaging modality. Results: A total of 169 metastatic lesions in 69 regions of 30 patients were detected by whole body MR DWI while 156 lesions in 68 regions of 29 patients were identified by skeletal scintigraphy. There were two cases negative in scintigraphy but positive in whole body MR DWI and one case positive in scintigraphy only. There were eight lesions negative in scintigraphy but positive in whole body MR DWI, mainly located in the spine, pelvis and femur. Seven lesions were only detected by scintigraphy, mainly located in the skull, sternum, clavicle and scapula. Conclusion: The whole body MR DWI reveals excellent consistency with skeletal scintigraphy regarding bone metastasis, and the two modalities are complementary for each other. (authors)

  15. Effect of alcohol consumption on whole-body protein turnover in healthy adults.

    Science.gov (United States)

    Wutzke, Klaus D; Krentz, Helga; Bruns, Gerrit

    2011-03-01

    The aim of the study was to investigate the whole-body protein turnover, either before or after continuous, moderate ethanol-induced oxidative stress by red wine consumption over a relatively short period in healthy volunteers. Ten healthy adults received an individual regular diet over 20 days. After 10 days, the subjects consumed 0.4 ml ethanol kg(-1) day(-1) as red wine together with dinner over a 10-day period. After 8 and 18 days, respectively, a (15)N-labelled yeast protein was administered in a dosage of 4.2 mg kg(-1) body weight. Urine and faeces were collected over 48 h, respectively. The (15)N-enrichment was measured by isotope ratio mass spectrometry, whereas the protein flux rates were calculated by a three-compartment model. The whole-body protein turnover without/with red wine consumption amounted to 3.73±0.6 and 3.49±0.6 g kg(-1) day(-1) (not significant), respectively. Moderate alcohol consumption does not induce significant short-term changes in the whole-body protein turnover of healthy adults.

  16. Caffeine protects mice against whole-body lethal dose of {gamma}-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    George, K.C.; Hebbar, S.A.; Kale, S.P.; Kesavan, P.C. [Biosciences Group, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    1999-06-01

    Administration of caffeine (1,3,7-trimethylxanthine), a major component of coffee, to Swiss mice at doses of 80 or 100 mg/kg body weight 60 min prior to whole-body lethal dose of {gamma}-irradiation (7.5 Gy) resulted in the survival of 70 and 63% of animals, respectively, at the above doses in contrast to absolutely no survivors (LD-100/25 days) in the group exposed to radiation alone. Pre-treatment with a lower concentration of caffeine (50 mg/kg) did not confer any radioprotection. The protection exerted by caffeine (80 mg/kg), however, was reduced from 70 to 50% if administered 30 min prior to irradiation. The trend statistics reveal that a dose of 80 mg/kg administered 60 min before whole-body exposure to 7.5 Gy is optimal for maximal radioprotection. However, caffeine (80 mg/kg) administered within 3 min after irradiation offered no protection. While there is documentation in the literature that caffeine is an antioxidant and radioprotector against the toxic pathway of radiation damage in a wide range of cells and organisms, this is the first report demonstrating unequivocally its potent radioprotective action in terms of survival of lethally whole-body irradiated mice. (author)

  17. Synthesis of dendrimer-based biotin radiopharmaceuticals to enhance whole-body clearance

    International Nuclear Information System (INIS)

    Sato, Noriko; Park, Chang W.; Kim, Hyung-Sik; Han, Eui-Sik; Wong, Karen J.; Paik, Ronald S.; Park, Luke S.; Yao Zhengsheng; Carrasquillo, Jorge A.; Paik, Chang H.

    2003-01-01

    To synthesize a biotin radiopharmaceutical that clears rapidly, dendrimer was used as a carrier and conjugated with succinimidyl 3-[ 125 I]iodobenzoate and tetrafluorophenyl norbiotinamidosuccinate. Then, succinic anhydride was used to reduce its pI. In mice, the non-succinylated product showed high liver (67% ID/g) and kidney (44% ID/g) uptakes and whole-body retention (94% ID) at 20 min that persisted for 12 hr. The corresponding organ uptakes (22% and 11% ID/g) and the whole-body retention (47% ID) were drastically reduced by succinylation (p<0.0001). Lysine co-injection further lowered renal uptake

  18. Dose evaluation on the basis of {sup 24}Na activity in the human body for the criticality accident at JCO Tokai nuclear fuel processing plant

    Energy Technology Data Exchange (ETDEWEB)

    Momose, T.; Tsujimura, N.; Tasaki, T.; Kanai, K.; Hayashi, N.; Shinohara, K. [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2001-11-01

    {sup 24}Na in the human body, activated by neutrons emitted at the JCO criticality accident, was observed for 62 subjects, where 148 subjects were measured by the whole body counter of JNC Tokai Works. The 148 subjects, including JCO employees and the contractors, residents neighboring the site and emergency service officers, were measured by the whole-body counter. The neutron-energy spectrum around the facility was calculated using neutron transport codes (ANISN and MCNP), and the relation between an amount of activated sodium in human body and neutron dose was evaluated from the calculated neutron energy spectrum and theoretical neutron capture probability by the human body. The maximum {sup 24}Na activity in the body was 7.7 kBq (83 Bq({sup 24}Na)/g({sup 23}Na)) and the relevant effective dose equivalent was 47 mSv. (author)

  19. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  20. Whole body cooling by immersion in water at moderate temperatures.

    Science.gov (United States)

    Marino, F; Booth, J

    1998-06-01

    This study investigated the potential use of whole body cooling by water immersion for lowering body temperatures prior to endurance exercise. Rectal temperature (Tre), mean skin temperature (Tsk), oxygen consumption (VO2), and ventilation (VE) were measured in 7 male and 3 female subjects who were immersed in a water bath for up to 60 min. Initial water temperature was 28.8+/-1.5 degrees C and decreased to 23.8+/-1.1 degrees C by the end of immersion. Pre-immersion Tre of 37.34+/-0.36 degrees C was not altered by 60 min water immersion but decreased to 36.64+/-0.34 degrees C at 3 min post immersion (p immersion. Reductions in Tre and Tsk resulted in reduced body heat content (Hc) of approximately 545 kJ (p immersion. VO2 and VE increased from pre-immersion values of 0.34+/-0.08 L x min(-1) and 6.2+/-1.4 L x min(-1) to 0.54+/-0.09 L x min(-) and 11.5+/-5.4 L x min(-1) at the end of immersion, respectively. Heart rate remained unchanged throughout immersion. These results indicate that whole body immersion in moderately cold water temperatures is an effective cooling maneuver for lowering body temperatures and body Hc in the absence of severe physiological responses generally associated with sudden cold stress.

  1. Automated analysis of whole skeletal muscle for muscular atrophy detection of ALS in whole-body CT images: preliminary study

    Science.gov (United States)

    Kamiya, Naoki; Ieda, Kosuke; Zhou, Xiangrong; Yamada, Megumi; Kato, Hiroki; Muramatsu, Chisako; Hara, Takeshi; Miyoshi, Toshiharu; Inuzuka, Takashi; Matsuo, Masayuki; Fujita, Hiroshi

    2017-03-01

    Amyotrophic lateral sclerosis (ALS) causes functional disorders such as difficulty in breathing and swallowing through the atrophy of voluntary muscles. ALS in its early stages is difficult to diagnose because of the difficulty in differentiating it from other muscular diseases. In addition, image inspection methods for aggressive diagnosis for ALS have not yet been established. The purpose of this study is to develop an automatic analysis system of the whole skeletal muscle to support the early differential diagnosis of ALS using whole-body CT images. In this study, the muscular atrophy parts including ALS patients are automatically identified by recognizing and segmenting whole skeletal muscle in the preliminary steps. First, the skeleton is identified by its gray value information. Second, the initial area of the body cavity is recognized by the deformation of the thoracic cavity based on the anatomical segmented skeleton. Third, the abdominal cavity boundary is recognized using ABM for precisely recognizing the body cavity. The body cavity is precisely recognized by non-rigid registration method based on the reference points of the abdominal cavity boundary. Fourth, the whole skeletal muscle is recognized by excluding the skeleton, the body cavity, and the subcutaneous fat. Additionally, the areas of muscular atrophy including ALS patients are automatically identified by comparison of the muscle mass. The experiments were carried out for ten cases with abnormality in the skeletal muscle. Global recognition and segmentation of the whole skeletal muscle were well realized in eight cases. Moreover, the areas of muscular atrophy including ALS patients were well identified in the lower limbs. As a result, this study indicated the basic technology to detect the muscle atrophy including ALS. In the future, it will be necessary to consider methods to differentiate other kinds of muscular atrophy as well as the clinical application of this detection method for early ALS

  2. Type test of the Rados MTS-N thermoluminescent dosimetry system for individual monitoring of whole body photons in HP (10); Teste de tipo do sistema de dosimetria termoluminescente RADOS MTS-N para monitoração individual de fótons de corpo inteiro em H{sub P}(10)

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, M.S.; Silva, E.R. da; Maurício, C.L.P., E-mail: max.das.ferreira@gmail.com, E-mail: everton@ird.gov.br, E-mail: claudia@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The Institute of Radioprotection and Dosimetry (IRD/CNEN-RJ), uses an automatic thermoluminescent dosimetry (TL) system for evaluation of whole body for photons with individual monitors RADOS MTS-N, with TLF detector of LiF: Mg, Ti. The objective of this work was to characterize this system for the evaluation of H{sub P} (10) operating magnitude. The measuring range is 0.2 mSv to 2 Sv, for photon energies from 20 keV to 1250 keV. Performance tests were done for the following characteristics: homogeneity of the monitors, system reproducibility, linearity, temperature and humidity effect, energy and angular dependence and fading. The acceptance requirements used to test system performance have been drawn from national and international documents. The results obtained prove that the system can be used to measure the occupational dose of photons in H{sub P} (10)

  3. RNA-Seq analysis of Gtf2ird1 knockout epidermal tissue provides potential insights into molecular mechanisms underpinning Williams-Beuren syndrome.

    Science.gov (United States)

    Corley, Susan M; Canales, Cesar P; Carmona-Mora, Paulina; Mendoza-Reinosa, Veronica; Beverdam, Annemiek; Hardeman, Edna C; Wilkins, Marc R; Palmer, Stephen J

    2016-06-13

    Williams-Beuren Syndrome (WBS) is a genetic disorder associated with multisystemic abnormalities, including craniofacial dysmorphology and cognitive defects. It is caused by a hemizygous microdeletion involving up to 28 genes in chromosome 7q11.23. Genotype/phenotype analysis of atypical microdeletions implicates two evolutionary-related transcription factors, GTF2I and GTF2IRD1, as prime candidates for the cause of the facial dysmorphology. Using a targeted Gtf2ird1 knockout mouse, we employed massively-parallel sequencing of mRNA (RNA-Seq) to understand changes in the transcriptional landscape associated with inactivation of Gtf2ird1 in lip tissue. We found widespread dysregulation of genes including differential expression of 78 transcription factors or coactivators, several involved in organ development including Hey1, Myf6, Myog, Dlx2, Gli1, Gli2, Lhx2, Pou3f3, Sox2, Foxp3. We also found that the absence of GTF2IRD1 is associated with increased expression of genes involved in cellular proliferation, including growth factors consistent with the observed phenotype of extreme thickening of the epidermis. At the same time, there was a decrease in the expression of genes involved in other signalling mechanisms, including the Wnt pathway, indicating dysregulation in the complex networks necessary for epidermal differentiation and facial skin patterning. Several of the differentially expressed genes have known roles in both tissue development and neurological function, such as the transcription factor Lhx2 which regulates several genes involved in both skin and brain development. Gtf2ird1 inactivation results in widespread gene dysregulation, some of which may be due to the secondary consequences of gene regulatory network disruptions involving several transcription factors and signalling molecules. Genes involved in growth factor signalling and cell cycle progression were identified as particularly important for explaining the skin dysmorphology observed in this

  4. Whole body interaction with public displays

    CERN Document Server

    Walter, Robert

    2017-01-01

    This book develops valuable new approaches to digital out-of-home media and digital signage in urban environments. It offers solutions for communicating interactive features of digital signage to passers-by. Digital out-of-home media and digital signage screens are becoming increasingly interactive thanks to touch input technology and gesture recognition. To optimize their conversion rate, interactive public displays must 1) attract attention, 2) communicate to passers-by that they are interactive, 3) explain the interaction, and 4) provide a motivation for passers-by to interact. This book highlights solutions to problems 2 and 3 above. The focus is on whole-body interaction, where the positions and orientations of users and their individual body parts are captured by specialized sensors (e.g., depth cameras). The book presents revealing findings from a field study on communicating interactivity, a laboratory on analysing visual attention, a field study on mid-air gestures, and a field study on using mid-air...

  5. Assessment of exposure to whole body vibration in Yazd city taxi drivers

    Directory of Open Access Journals (Sweden)

    F Samoori sakhvidi

    2016-11-01

    Full Text Available Assessment of exposure to whole body vibration in Yazd city taxi drivers Samoori-Sakhvidi F (MSc* Barkhordari A (PhD** Dehghani A (PhD*** Tavakoli-Manesh S (MSc**** *Corresponding Author: MSc Student in Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran ** Professor, Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran *** Professor, Department of Statistics and Epidemiology, Shahid Sadoughi University of Medical Sciences, Yazd, Iran **** MSc Student in Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran Abstract Introduction: One of the most common sources of whole body vibration are vehicles in which the driver is exposed to vibration caused by the vehicle and the road. Including the people who continuously exposure to whole-body vibration can be noted to taxi drivers. Taxi drivers during their work shift Encountered with numerous deleterious effects such as noise, vibration, air pollution, and psychological stress and long work shifts. Long-term exposure to whole body vibration in the taxi drivers can communicate with adverse effects such as reduce perception, annoyance, disturbance of vision and fine motor tasks, spinal cord injury, damage to the digestive and reproductive systems. The purpose of this study was cross - sectional study of whole body vibration exposure in Yazd city taxi drivers. Methods: This study was designed to evaluate exposure to whole body vibration in taxi drivers, vibration measurement Was carried out in 80 taxi from 3 vehicle (Samand-Peugeot 405 and Pridein 3 mileage groups, with 63 male drivers and 17 female drivers. parameters Including the vibration Weighing the acceleration frequency (rms, Equivalent acceleration (Aeq and vibration doseVDV in 3-axis was recorded. The results obtained were compared with the values recommended by the standard (ISO 2631-1. Results: The mean (rms acceleration

  6. Countering 21st Century Threats

    DEFF Research Database (Denmark)

    Scharling Pedersen, Peter; Pillai, Chad M.; Hun, Lee Jae

    2015-01-01

    ), Counter-Terrorism (CT), and Security and Stability Operations (SSO). • Establishing a construct that allows a strategic Whole-of-Government capacity for operations coordinated by joint interagency task forces. • Continue to developing the Global SOF network. • Increased intelligence sharing in areas...

  7. Whole Body Vibration Improves Cognition in Healthy Young Adults

    NARCIS (Netherlands)

    Regterschot, G. Ruben H.; Van Heuvelen, Marieke J. G.; Zeinstra, Edzard B.; Fuermaier, Anselm B.M.; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van der Zee, Eddy A.

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5 +/- 2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration

  8. Simplified calibration and evaluation procedures for improvised whole body gamma spectrometry in emergency situations

    International Nuclear Information System (INIS)

    Malatova, I.; Bucina, I.; Drabova, D.; Cespirova, I.

    2000-01-01

    A semiconductor gamma spectrometer could be used for the rapid estimation of internal contamination of the people in cases of accidents even when no special calibration for whole body counting is prepared. Generic transfer factors for calculation of the whole body detection efficiency from the 25 cm distant point source detection efficiency are presented. Generic dependence of parameters of power function describing the detector efficiency for point source in 25 cm on the detector relative efficiency given by producer was derived from calibration of 18 detectors with relative efficiency from 1.4% to 62%. Minimum detectable activity for various backgrounds and the uncertainty of the estimate of whole body retention are presented, too. (author)

  9. Effects of the whole-body cryotherapy on NTproBNP, hsCRP and troponin I in athletes.

    Science.gov (United States)

    Banfi, Giuseppe; Melegati, Gianluca; Barassi, Alessandra; d'Eril, Gianlodovico Melzi

    2009-11-01

    Whole-body cryotherapy refers to brief exposure to very cold air for treating symptoms of various illnesses. In sports medicine, whole-body cryotherapy is administered to improve recovery from muscular trauma. As specific studies are lacking, we measured cardiac markers in 10 top-level rugby players of the Italian National team before and after a 1-week course of daily sessions of whole-body cryotherapy. All subjects continued with the same training workload as that of the previous weeks. N-terminal pro B-type natriuretic peptide (NTproBNP) levels increased but remained within the normal range, whilst troponin I (TnI) and high sensitivity C-reactive protein (hsCRP) were unchanged. Whole-body cryotherapy did not impair cardiac function in this sample of elite athletes.

  10. A statistical observation on some subjects in the whole body computed tomographic examination

    International Nuclear Information System (INIS)

    Murakami, Shozo; Matsumoto, Shigekazu; Murakawa, Yasuhiro; Morimoto, Mitsuo; Nakai, Toshio

    1983-01-01

    Since the whole body CT (computed tomography) unit (GE, CT/T) was installed in our hospital in April, 1982, a total of 2884 cases have been examined by this whole body scanner for one year from April, 1982 to March, 1983. An analysis of the relationship between the situations of the subjects in and the results of whole body CT examination disclosed some very interesting facts. Up to the present time such a study has scarcely made. That is why we wanted to make this report. The results obtained are as follows: 1. Whole body CT examinations were performed on the patients of advanced age more frequently than on those of young age and performed most frequently on the group in the sixties. 2. The number of CT examinations performed on head and abdomen of the patients was 86.7% of a total of 2884 cases. 3. Enhanced CT examinations were perfomed on 26.1% of 2884 cases and most frequently on the group in the teens. 4. The percentage of the abnormal findings found in 2884 cases was 61.5% and this rate was higher than that shown in the reports made by us in 1980 and 1982, respectively. (author)

  11. A DXA Whole Body Composition Cross-Calibration Experience: Evaluation With Humans, Spine, and Whole Body Phantoms.

    Science.gov (United States)

    Krueger, Diane; Libber, Jessie; Sanfilippo, Jennifer; Yu, Hui Jing; Horvath, Blaine; Miller, Colin G; Binkley, Neil

    2016-01-01

    substantial lean and fat differences observed using BBCP and in vivo assessments. Consequently, spine phantoms are inadequate for dual-energy X-ray absorptiometry whole body composition cross-calibration. Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  12. [Application of GVF snake model in segmentation of whole body bone SPECT image].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2008-02-01

    Limited by the imaging principle of whole body bone SPECT image, the gray value of bladder area is quite high, which affects the image's brightness, contrast and readability. In the meantime, the similarity between bladder area and focus makes it difficult for some images to be segmented automatically. In this paper, an improved Snake model, GVF Snake, is adopted to automatically segment bladder area, preparing for further processing of whole body bone SPECT images.

  13. Visuospatial memory computations during whole-body rotations in roll

    NARCIS (Netherlands)

    Pelt, S. van; Gisbergen, J.A.M. van; Medendorp, W.P.

    2005-01-01

    We used a memory-saccade task to test whether the location of a target, briefly presented before a whole-body rotation in roll, is stored in egocentric or in allocentric coordinates. To make this distinction, we exploited the fact that subjects, when tilted sideways in darkness, make systematic

  14. Computational modeling of blast induced whole-body injury: a review.

    Science.gov (United States)

    Chanda, Arnab; Callaway, Christian

    2018-02-01

    Blast injuries affect millions of lives across the globe due to its traumatic after effects on the brain and the whole body. To date, military grade armour materials are designed to mitigate ballistic and shrapnel attacks but are less effective in resisting blast impacts. In order to improve blast absorption characteristics of armours, the first key step is thoroughly understands the effects of blasts on the human body itself. In the last decade, a plethora of experimental and computational work has been carried out to investigate the mechanics and pathophysiology of Traumatic Brain Injury (TBI). However, very few attempts have been made so far to study the effect of blasts on the various other parts of the body such as the sensory organs (eyes and ears), nervous system, thorax, extremities, internal organs (such as the lungs) and the skeletal system. While an experimental evaluation of blast effects on such physiological systems is difficult, developing finite element (FE) models could allow the recreation of realistic blast scenarios on full scale human models and simulate the effects. The current article reviews the state-of-the-art in computational research in blast induced whole-body injury modelling, which would not only help in identifying the areas in which further research is required, but would also be indispensable for understanding body location specific armour design criteria for improved blast injury mitigation.

  15. Head Exposure to Cold during Whole-Body Cryostimulation: Influence on Thermal Response and Autonomic Modulation

    Science.gov (United States)

    Louis, Julien; Schaal, Karine; Bieuzen, François; Le Meur, Yann; Filliard, Jean-Robert; Volondat, Marielle; Brisswalter, Jeanick; Hausswirth, Christophe

    2015-01-01

    Recent research on whole-body cryotherapy has hypothesized a major responsibility of head cooling in the physiological changes classically reported after a cryostimulation session. The aim of this experiment was to verify this hypothesis by studying the influence of exposing the head to cold during whole-body cryostimulation sessions, on the thermal response and the autonomic nervous system (ANS). Over five consecutive days, two groups of 10 participants performed one whole-body cryostimulation session daily, in one of two different systems; one exposing the whole-body to cold (whole-body cryostimulation, WBC), and the other exposing the whole-body except the head (partial-body cryostimulation, PBC).10 participants constituted a control group (CON) not receiving any cryostimulation. In order to isolate the head-cooling effect on recorded variables, it was ensured that the WBC and PBC systems induced the same decrease in skin temperature for all body regions (mean decrease over the 5 exposures: -8.6°C±1.3°C and -8.3±0.7°C for WBC and PBC, respectively), which persisted up to 20-min after the sessions (P20). The WBC sessions caused an almost certain decrease in tympanic temperature from Pre to P20 (-0.28 ±0.11°C), while it only decreased at P20 (-0.14±0.05°C) after PBC sessions. Heart rate almost certainly decreased after PBC (-8.6%) and WBC (-12.3%) sessions. Resting vagal-related heart rate variability indices (the root-mean square difference of successive normal R-R intervals, RMSSD, and high frequency band, HF) were very likely to almost certainly increased after PBC (RMSSD:+49.1%, HF: +123.3%) and WBC (RMSSD: +38.8%, HF:+70.3%). Plasma norepinephrine concentration was likely increased in similar proportions after PBC and WBC, but only after the first session. Both cryostimulation techniques stimulated the ANS with a predominance of parasympathetic tone activation from the first to the fifth session and in slightly greater proportion with WBC than PBC

  16. Effects of whole-body and partial-body x irradiation upon epidermal mitotic activity during wound healing in mouse skin

    International Nuclear Information System (INIS)

    Kobayashi, K.

    1977-01-01

    Mitotic activity of normal (unwounded) and wounded skin was measured in the control (nonirradiated) and whole-body or partial-body x-irradiated mouse. Higher mitotic activity in the anterior than in the posterior region of the body was found in both the normal and the wounded skin of the control mouse. Whole-body irradiation (500 R) depressed completely the mitotic activity of normal skin 2 to 4 days after irradiation. In spite of this depression in mitotic activity, a surgical incision made 1 to 3 days after irradiation could induce a burst of proliferation after an inhibition of an initial mitosis increase. When the animals were partially irradiated with 500 R 3 days before wounding, it was shown that mitosis at 24 hr after wounding was inhibited markedly by the local effect of irradiation and that mitosis also could be inhibited diversely by the abscopal effect of irradiation. Because of a close similarity of sequential mitotic patterns between whole-body-irradiated and flapped-skin-only-irradiated groups (direct irradiation), the effect of irradiation upon mitosis was considered to be primarily local. Some discussions were made concerning the possible reasons which made a difference in mitotic patterns between the head-only-irradiated group, the irradiated group including the head and other parts of the body except for the skin flap

  17. Evaluation of whole-body MR to CT deformable image registration.

    Science.gov (United States)

    Akbarzadeh, A; Gutierrez, D; Baskin, A; Ay, M R; Ahmadian, A; Riahi Alam, N; Lövblad, K O; Zaidi, H

    2013-07-08

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based on B-spline transformation was performed using optimized parameters of the elastix package based on the Insight Toolkit (ITK) framework. Twenty-eight (17 male and 11 female) clinical studies were used in this work. The registration was evaluated using anatomical landmarks and segmented organs. In addition to 16 anatomical landmarks, three key organs (brain, lungs, and kidneys) and the entire body volume were segmented for evaluation. Several parameters--such as the Euclidean distance between anatomical landmarks, target overlap, Dice and Jaccard coefficients, false positives and false negatives, volume similarity, distance error, and Hausdorff distance--were calculated to quantify the quality of the registration algorithm. Dice coefficients for the majority of patients (> 75%) were in the 0.8-1 range for the whole body, brain, and lungs, which satisfies the criteria to achieve excellent alignment. On the other hand, for kidneys, Dice coefficients for volumes of 25% of the patients meet excellent volume agreement requirement, while the majority of patients satisfy good agreement criteria (> 0.6). For all patients, the distance error was in 0-10 mm range for all segmented organs. In summary, we optimized and evaluated the accuracy of an MR to CT deformable registration algorithm. The registered images constitute a useful 3D whole-body MR-CT atlas suitable for the development and evaluation of novel MR-guided attenuation correction procedures on hybrid PET-MR systems.

  18. Whole-body cryostimulation increases parasympathetic outflow and decreases core body temperature.

    Science.gov (United States)

    Zalewski, Pawel; Bitner, Anna; Słomko, Joanna; Szrajda, Justyna; Klawe, Jacek J; Tafil-Klawe, Malgorzata; Newton, Julia L

    2014-10-01

    The cardiovascular, autonomic and thermal response to whole-body cryostimulation exposure are not completely known. Thus the aim of this study was to evaluate objectively and noninvasively autonomic and thermal reactions observed after short exposure to very low temperatures. We examined 25 healthy men with mean age 30.1 ± 3.7 years and comparable anthropomorphical characteristic. Each subject was exposed to cryotherapeutic temperatures in a cryogenic chamber for 3 min (approx. -120 °C). The cardiovascular and autonomic parameters were measured noninvasively with Task Force Monitor. The changes in core body temperature were determined with the Vital Sense telemetric measurement system. Results show that 3 min to cryotherapeutic temperatures causes significant changes in autonomic balance which are induced by peripheral and central blood volume changes. Cryostimulation also induced changes in core body temperature, maximum drop of core temperature was observed 50-60 min after the stimulation. Autonomic and thermal reactions to cryostimulation were observed up to 6 h after the exposure and were not harmful for examined subjects. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  20. Whole-body MR angiography with body coil acquisition at 3 T in patients with peripheral arterial disease using the contrast agent gadofosveset trisodium

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Eiberg, Jonas P; Løgager, Vibeke B

    2009-01-01

    Whole-body magnetic resonance angiography (WB-MRA) at 3 T with body coil acquisition has not previously been investigated. In this study, WB-MRA was performed in this manner using the blood pool contrast agent gadofosveset trisodium.......Whole-body magnetic resonance angiography (WB-MRA) at 3 T with body coil acquisition has not previously been investigated. In this study, WB-MRA was performed in this manner using the blood pool contrast agent gadofosveset trisodium....

  1. Force direction patterns promote whole body stability even in hip-flexed walking, but not upper body stability in human upright walking

    Science.gov (United States)

    Müller, Roy; Rode, Christian; Aminiaghdam, Soran; Vielemeyer, Johanna; Blickhan, Reinhard

    2017-11-01

    Directing the ground reaction forces to a focal point above the centre of mass of the whole body promotes whole body stability in human and animal gaits similar to a physical pendulum. Here we show that this is the case in human hip-flexed walking as well. For all upper body orientations (upright, 25°, 50°, maximum), the focal point was well above the centre of mass of the whole body, suggesting its general relevance for walking. Deviations of the forces' lines of action from the focal point increased with upper body inclination from 25 to 43 mm root mean square deviation (RMSD). With respect to the upper body in upright gait, the resulting force also passed near a focal point (17 mm RMSD between the net forces' lines of action and focal point), but this point was 18 cm below its centre of mass. While this behaviour mimics an unstable inverted pendulum, it leads to resulting torques of alternating sign in accordance with periodic upper body motion and probably provides for low metabolic cost of upright gait by keeping hip torques small. Stabilization of the upper body is a consequence of other mechanisms, e.g. hip reflexes or muscle preflexes.

  2. Morphological studies on the healing process of tooth extraction wounds in whole body irradiated rats

    International Nuclear Information System (INIS)

    Hosokawa, Yoichiro

    1991-01-01

    The present studies were performed to investigate the healing process of the tooth extraction wound in whole body irradiated rats and to clarify the effect of irradiation on bone metabolism. One hundred and seven Wistar rats of about 100 g body weight were used and divided into 3 groups. Whole body irradiated rats were given single exposure with a dose of 8 Gy. The region of the left upper molars of local irradiated rats as controls, was exposed to 8 Gy. On the 7th day after irradiation, the left upper first molar of each rat was extracted. The rats were sacrificed at intervals of 1 to 14 days after extraction. Non-irradiated rats were sacrificed at the same intervals after extraction. The maxillary bone including the extraction wound was evaluated, histologically, histometrically and ultrastructurally. From the histological and histometrical findings, the difference of the healing process between non-irradiated rats and locally irradiated rats is not significant. In whole body irradiated rats, the healing process especially in the socket was disturbed. The osteoblastic new bone formation following production of granulation tissue was interfered with. Ultrastructurally, the cytoplasmic organellae were poorly developed in the osteoblast and osteoid formation was reduced in the socket. But periosteal new bone formation was the same as that of the locally irradiated rats. In whole body irradiated rats, the osteoclasts in the interradicular alveolar bone were decreased and have smaller nuclei, compared with non-irradiated and locally irradiated rats. Histometrically, the amount of bone loss was decreased in whole body irradiated rats. Ultrastructurally, the cyoplasmic organellae and ruffled border were poorly developed in the osteoclasts of whole body irradiated rats. The findings suggested that irradiation induced cytological changes not only in osteoblasts but in osteoclasts and these changes resulted in the delayed healing of extraction wound. (author) 106 refs

  3. Morphological studies on the healing process of tooth extraction wounds in whole body irradiated rats

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Yoichiro (Hokkaido Univ., Sapporo (Japan). School of Dentistry)

    1991-06-01

    The present studies were performed to investigate the healing process of the tooth extraction wound in whole body irradiated rats and to clarify the effect of irradiation on bone metabolism. One hundred and seven Wistar rats of about 100 g body weight were used and divided into 3 groups. Whole body irradiated rats were given single exposure with a dose of 8 Gy. The region of the left upper molars of local irradiated rats as controls, was exposed to 8 Gy. On the 7th day after irradiation, the left upper first molar of each rat was extracted. The rats were sacrificed at intervals of 1 to 14 days after extraction. Non-irradiated rats were sacrificed at the same intervals after extraction. The maxillary bone including the extraction wound was evaluated, histologically, histometrically and ultrastructurally. From the histological and histometrical findings, the difference of the healing process between non-irradiated rats and locally irradiated rats is not significant. In whole body irradiated rats, the healing process especially in the socket was disturbed. The osteoblastic new bone formation following production of granulation tissue was interfered with. Ultrastructurally, the cytoplasmic organellae were poorly developed in the osteoblast and osteoid formation was reduced in the socket. But periosteal new bone formation was the same as that of the locally irradiated rats. In whole body irradiated rats, the osteoclasts in the interradicular alveolar bone were decreased and have smaller nuclei, compared with non-irradiated and locally irradiated rats. Histometrically, the amount of bone loss was decreased in whole body irradiated rats. Ultrastructurally, the cyoplasmic organellae and ruffled border were poorly developed in the osteoclasts of whole body irradiated rats. The findings suggested that irradiation induced cytological changes not only in osteoblasts but in osteoclasts and these changes resulted in the delayed healing of extraction wound. (author) 106 refs.

  4. Whole body vibration improves attention and motor performance in ...

    African Journals Online (AJOL)

    Background: Whole body vibration (WBV) is a form of physical stimulation via mechanical vibrations transmitted to a subject. It is assumed that WBV induces sensory stimulation in cortical brain regions through the activation of skin and muscle receptors responding to the vibration. The effects of WBV on muscle strength are ...

  5. Implementation of ISO 28218 quality system in the laboratory of body radioactivity counter CIEMAT

    International Nuclear Information System (INIS)

    Navarro Amaro, J. F.; Perez Lopez, B.; Lopez Ponte, M. A.; Perez Jimenez, C.

    2011-01-01

    The laboratory of body radioactivity counter has implemented IS0 28218 standard Performance Criteria for Radio bioassay in all measured in vivo techniques of internal contamination in the human organism in monitoring programs defined by the Personal Dosimetry Service Internal CIEMAT. The application of this rule in the laboratory's quality system is essential to meet the technical requirements of the standard IS0/IEC 17025 with the purpose of obtaining ENAC accreditation as a testing laboratory and calibration within the framework of the accreditation of Service CIEMAT Radiation Dosimetry. (Author)

  6. Revisiting the Body-Schema Concept in the Context of Whole-Body Postural-Focal Dynamics

    Science.gov (United States)

    Morasso, Pietro; Casadio, Maura; Mohan, Vishwanathan; Rea, Francesco; Zenzeri, Jacopo

    2015-01-01

    The body-schema concept is revisited in the context of embodied cognition, further developing the theory formulated by Marc Jeannerod that the motor system is part of a simulation network related to action, whose function is not only to shape the motor system for preparing an action (either overt or covert) but also to provide the self with information on the feasibility and the meaning of potential actions. The proposed computational formulation is based on a dynamical system approach, which is linked to an extension of the equilibrium-point hypothesis, called Passive Motor Paradigm: this dynamical system generates goal-oriented, spatio-temporal, sensorimotor patterns, integrating a direct and inverse internal model in a multi-referential framework. The purpose of such computational model is to operate at the same time as a general synergy formation machinery for planning whole-body actions in humanoid robots and/or for predicting coordinated sensory–motor patterns in human movements. In order to illustrate the computational approach, the integration of simultaneous, even partially conflicting tasks will be analyzed in some detail with regard to postural-focal dynamics, which can be defined as the fusion of a focal task, namely reaching a target with the whole-body, and a postural task, namely maintaining overall stability. PMID:25741274

  7. Revisiting the body-schema concept in the context of whole-body postural-focal dynamics.

    Science.gov (United States)

    Morasso, Pietro; Casadio, Maura; Mohan, Vishwanathan; Rea, Francesco; Zenzeri, Jacopo

    2015-01-01

    The body-schema concept is revisited in the context of embodied cognition, further developing the theory formulated by Marc Jeannerod that the motor system is part of a simulation network related to action, whose function is not only to shape the motor system for preparing an action (either overt or covert) but also to provide the self with information on the feasibility and the meaning of potential actions. The proposed computational formulation is based on a dynamical system approach, which is linked to an extension of the equilibrium-point hypothesis, called Passive Motor Paradigm: this dynamical system generates goal-oriented, spatio-temporal, sensorimotor patterns, integrating a direct and inverse internal model in a multi-referential framework. The purpose of such computational model is to operate at the same time as a general synergy formation machinery for planning whole-body actions in humanoid robots and/or for predicting coordinated sensory-motor patterns in human movements. In order to illustrate the computational approach, the integration of simultaneous, even partially conflicting tasks will be analyzed in some detail with regard to postural-focal dynamics, which can be defined as the fusion of a focal task, namely reaching a target with the whole-body, and a postural task, namely maintaining overall stability.

  8. Revisiting the body-schema concept in the context of Whole-Body Postural-Focal Dynamics

    Directory of Open Access Journals (Sweden)

    Pietro eMorasso

    2015-02-01

    Full Text Available The body schema concept is revisited in the context of embodied cognition, further developing the theory formulated by Marc Jeannerod that the motor system is part of a simulation network related to action, whose function is not only to shape the motor system for preparing an action (either overt or covert, but also to provide the self with information on the feasibility and the meaning of potential actions. The proposed computational formulation is based on a dynamical system approach, which is linked to an extension of the Equilibrium Point Hypothesis, called Passive Motor Paradigm: this dynamical system generates goal-oriented, spatio-temporal, sensorimotor patterns, integrating a direct and inverse internal model in a multi-referential framework. The purpose of such computational model is to operate at the same time as a general synergy formation machinery for planning whole-body actions in humanoid robots and/or for predicting coordinated sensory-motor patterns in human movements. In order to illustrate the computational approach, the integration of simultaneous, even partially conflicting tasks will be analyzed in some detail with regard to postural-focal dynamics, which can be defined as the fusion of a focal task, namely reaching a target with the whole-body, and a postural task, namely maintaining overall stability.

  9. Scanning personnel for internal deposition of radioactive material with personnel contamination whole body friskers and portal monitors

    International Nuclear Information System (INIS)

    Lobdell, J.L.

    1996-01-01

    The potential for using personnel contamination devices such as whole body friskers and portal monitors for internal contamination monitoring was evaluated. Internally deposited radioactive material is typically determined with whole body counting systems. Whole body counts have traditionally been performed on personnel when they report for work, on a periodic basis (i.e., annually), when an uptake is suspected, and on termination. These counts incur significant expense. The monitored personnel pass through whole body friskers and portal monitors daily. This investigation was performed to determine if the external contamination monitors could provide an alternative to the more Costly whole body counting. The ability to detect 1% of a DAC for critical radioisotopes was applied as a detection criteria for this investigation. The results of whole body counts were used to identify the typical internal contamination radionuclides. From this list, the radioisotopes that would be the most difficult to measure were identified. From this review, 60 Co and 131 I were determined to be the critical radionuclides. One percent of a DAC for each isotope was placed, one at a time, in a humanoid phantom. The phantom was placed in the whole body frisker and open-quotes countedclose quotes. The phantom was carried through the portal monitor at a speed equivalent to a person walking through the monitor. Frequency of detection was derived for both systems. Practical aspects of integrating this screening system with traditional internal dosimetry programs are discussed

  10. Study on the usefulness of whole body SPECT coronal image, MIP image in {sup 67}Ga scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Seiji [Kurume Univ., Fukuoka (Japan). Hospital; Ishibashi, Masatoshi; Kurata, Seiji; Morita, Seiichirou; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine; Fukushima, Shigehiro [Kyushu Inst. of Design, Fukuoka (Japan). Graduate School of Auditory and Visual Communication Sciences; Umezaki, Noriyoshi [Daiichi Coll. of Pharmaceutical Sciences, Fukuoka (Japan)

    2002-05-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with {sup 67}Ga-citrate ({sup 67}Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  11. Whole body dual X-ray absorptiometry for bone mineral density and body composition using a flat panel detector

    International Nuclear Information System (INIS)

    Dinten, J.M.; Robert-Coutant, C.; Gonon, G.; Bordy, T.

    2003-01-01

    Whole-body dual-energy X-ray absorptiometry (DXA) systems are used for the determination of bone mineral density (BMD) but also for body composition estimates (lean mass and fat mass). The calculation is based on the difference in attenuation of body tissues for a low-energy of about 50 KeV and a high-energy of about 80-100 KeV. The measurement of dual-energy projections allows first to compute to the body composition in the non-bone area, and then to extrapolate the fat / lean ratio of soft tissue into the bone area in order to compute the BMD. Since detectors have limited area, a whole body examination requires a scan of the patient and a reconstruction process in order to build up a large field image from smaller radiographs. This reconstruction process must keep the quantitative value of the radiographs, and avoid any distortion which could be a consequence of the conic acquisition geometry. The cone angle is low (6 at maximum) and the large overlap between radiographs helps to reconstruct an image equivalent with a parallel-beam geometry. Scatter is corrected from the radiographs before reconstruction, as described in a previous paper ('Dual-energy X-rays absorptiometry using a 2D digital radiography detector. Application to bone densitometry', SPIE Medical Imaging 2001, Medical Physics). We have developed an original reconstruction method dedicated to whole-body examinations which will be described. Thanks to the quasi-radiologic quality of the detector, reconstructed images are of very good quality and this makes the measurement of BMD and fat / lean masses easier. (author)

  12. Optimized workflow and imaging protocols for whole-body oncologic PET/MRI.

    Science.gov (United States)

    Ishii, Shirou; Hara, Takamitsu; Nanbu, Takeyuki; Suenaga, Hiroki; Sugawara, Shigeyasu; Kuroiwa, Daichi; Sekino, Hirofumi; Miyajima, Masayuki; Kubo, Hitoshi; Oriuchi, Noboru; Ito, Hiroshi

    2016-11-01

    Although PET/MRI has the advantages of a simultaneous acquisition of PET and MRI, high soft-tissue contrast of the MRI images, and reduction of radiation exposure, its low profitability and long acquisition time are significant problems in clinical settings. Thus, MRI protocols that meet oncological purposes need to be used in order to reduce examination time while securing detectability. Currently, half-Fourier acquisition single-shot turbo spin echo and 3D-T1 volumetric interpolated breath-hold examination may be the most commonly used sequences for whole-body imaging due to their shorter acquisition time and higher diagnostic accuracy. Although there have been several reports that adding diffusion weighted image (DWI) to PET/MRI protocol has had no effect on tumor detection to date, in cases of liver, kidney, bladder, and prostate cancer, the use of DWI may be beneficial in detecting lesions. Another possible option is to scan each region with different MRI sequences instead of scanning the whole body using one sequence continuously. We herein report a workflow and imaging protocols for whole-body oncologic PET/MRI using an integrated system in the clinical routine, designed for the detection, for example by cancer screening, of metastatic lesions, in order to help future users optimize their workflow and imaging protocols.

  13. Wireless Cortical Brain-Machine Interface for Whole-Body Navigation in Primates

    Science.gov (United States)

    Rajangam, Sankaranarayani; Tseng, Po-He; Yin, Allen; Lehew, Gary; Schwarz, David; Lebedev, Mikhail A.; Nicolelis, Miguel A. L.

    2016-03-01

    Several groups have developed brain-machine-interfaces (BMIs) that allow primates to use cortical activity to control artificial limbs. Yet, it remains unknown whether cortical ensembles could represent the kinematics of whole-body navigation and be used to operate a BMI that moves a wheelchair continuously in space. Here we show that rhesus monkeys can learn to navigate a robotic wheelchair, using their cortical activity as the main control signal. Two monkeys were chronically implanted with multichannel microelectrode arrays that allowed wireless recordings from ensembles of premotor and sensorimotor cortical neurons. Initially, while monkeys remained seated in the robotic wheelchair, passive navigation was employed to train a linear decoder to extract 2D wheelchair kinematics from cortical activity. Next, monkeys employed the wireless BMI to translate their cortical activity into the robotic wheelchair’s translational and rotational velocities. Over time, monkeys improved their ability to navigate the wheelchair toward the location of a grape reward. The navigation was enacted by populations of cortical neurons tuned to whole-body displacement. During practice with the apparatus, we also noticed the presence of a cortical representation of the distance to reward location. These results demonstrate that intracranial BMIs could restore whole-body mobility to severely paralyzed patients in the future.

  14. Improved quality of image got through whole-body CT scanner

    International Nuclear Information System (INIS)

    Asahina, Kiyotaka

    1980-01-01

    The quality of brain images taken with a whole-body CT scanner has so far been generally inferior in quality to those got through a CT scanner exclusively used for brains. In order to improve the whole-body CT scanner so as to get better brain image, its detection system has been made multichannel; the capacity of its X-ray tube, increased; and its software, innovated. As a result, the spatial resolution has been improved from 5.51 p/cm to 9.01 p/cm, the contrast resolution has been improved from 3.2 mm% to 1.5 mm%, with the noise maintained at 0.5%. In clinical examination, the image quality has been improved equally well for brains, abdomens and lungs. Especially high appreciation is given to the diagnosis information got through this new scanner. (author)

  15. Retrospective Evaluation of Whole Body Computed Tomography for Tumor Staging in Dogs with Primary Appendicular Osteosarcoma.

    Science.gov (United States)

    Talbott, Jessica L; Boston, Sarah E; Milner, Rowan J; Lejeune, Amandine; Souza, Carlos H de M; Kow, Kelvin; Bacon, Nicholas J; Hernandez, Jorge A

    2017-01-01

    To evaluate whole body computed tomography (CT) for staging canine appendicular osteosarcoma. Retrospective case series. Client-owned dogs diagnosed with appendicular osteosarcoma (n=39). Medical records for client-owned dogs diagnosed with appendicular osteosarcoma from August 2008 to July 2014 were reviewed. Dogs were included if they had a confirmed diagnosis of appendicular osteosarcoma and were staged using whole body CT. Data collected included signalment, body weight, primary tumor location, serum alkaline phosphatase (ALP) activity, findings on 3-view thoracic radiographs, cytologic or histologic results, and findings on CT. Thirty-nine dogs (median age 8.5 years; median body weight 37 kg) had osteosarcoma of the distal radius (n=17), proximal humerus (11) and other sites. Serum ALP activity was elevated in 14 dogs. Bone metastasis was not detected in any dog on whole body CT. Pulmonary metastasis was considered definitive on CT based on board certified radiologist assessment in 2/39 dogs (5%). Two additional dogs (2/39, 5%) had soft tissue masses diagnosed on CT, consistent with concurrent, non-metastatic malignancies. Bone metastases were not identified in any dog with whole body CT. Thoracic and abdominal CT detected lung lesions and concurrent neoplasia in dogs with primary appendicular osteosarcoma. Whole body CT may be a useful adjunct to other screening tests for disseminated malignancy. © 2016 The American College of Veterinary Surgeons.

  16. Effects of Whole-Body Vibration Therapy in Patients with Fibromyalgia: A Systematic Literature Review

    Directory of Open Access Journals (Sweden)

    Daniel Collado-Mateo

    2015-01-01

    Full Text Available Objective. To review the literature on the effects of whole-body vibration therapy in patients with fibromyalgia. Design. Systematic literature review. Patients. Patients with fibromyalgia. Methods. An electronic search of the literature in four medical databases was performed to identify studies on whole-body vibration therapy that were published up to the 15th of January 2015. Results. Eight articles satisfied the inclusion and exclusion criteria and were analysed. According to the Dutch CBO guidelines, all selected trials had a B level of evidence. The main outcomes that were measured were balance, fatigue, disability index, health-related quality of life, and pain. Whole-body vibration appeared to improve the outcomes, especially balance and disability index. Conclusion. Whole-body vibration could be an adequate treatment for fibromyalgia as a main therapy or added to a physical exercise programme as it could improve balance, disability index, health-related quality of life, fatigue, and pain. However, this conclusion must be treated with caution because the paucity of trials and the marked differences between existing trials in terms of protocol, intervention, and measurement tools hampered the comparison of the trials.

  17. In-vivo assessment of whole-body radioisotope burdens at the Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Vasilik, D.G.; Aikin, I.C.

    1983-08-01

    The Los Alamos National Laboratory program for in-vivo measurements includes the capability for the whole-body assessment of body burdens for x-ray or gamma-ray emitting radioisotopes. This capability is an important part of the health and safety program at Los Alamos where a wide variety of radioisotopes are utilized. This report addresses the whole body portion of our in-vivo measurement capabilities. Whole-body measurements at Los Alamos make use of a hyperpure germanium (HpGe) detector and a lithium-drifted germanium [Ge(Li)] detector for identification and quantification of radioisotopes. Analysis results are interpreted in terms of two basic statistical measures of detection limits. One measure is called the minimum significant measured activity (MSMA), which is interpreted as meaning that there is some activity in the body. The second measure is called the minimum detectable true activity (MDTA), which is defined as the smallest amount of activity required to be in the body in order that a measurement of an individual can be expected to imply correctly the presence of activity with a predetermined degree of confidence. 7 references, 8 figures

  18. The whole-body incorporation of radioactive caesium in Switzerland during the last 30 years: a survey of young persons in Geneva and some measurements of Belarusian and Ukrainian children

    International Nuclear Information System (INIS)

    Donath, A.

    1996-01-01

    In a cross-sectional study, at least 40 young men and women about 18 years old (half of each sex) were selected each year, and the body concentration of 137 Cs was measured in a whole-body counter. This radioisotope, with a half-life of 30 years, originates from the atom bomb explosions in the atmosphere, which were stopped in 1963, or from the accident at Chernobyl. The concentrations due to the emissions from this reactor remained below one-third of the values due to atomic bombs. The results in children from Belarus who spent a few weeks in Switzerland in the summer are lower than would have been expected according to the literature from Russia, but correspond to those recently obtained in situ by international scientific teams. 6 refs, 1 fig., 1 tab

  19. Acoustical method of whole-body hydration status monitoring

    Science.gov (United States)

    Sarvazyan, A. P.; Tsyuryupa, S. N.; Calhoun, M.; Utter, A.

    2016-07-01

    An acoustical handheld hydration monitor (HM) for assessing the water balance of the human body was developed. Dehydration is a critical public health problem. Many elderly over age of 65 are particularly vulnerable as are infants and young children. Given that dehydration is both preventable and reversible, the need for an easy-to-perform method for the detection of water imbalance is of the utmost clinical importance. The HM is based on an experimental fact that ultrasound velocity in muscle is a linear function of water content and can be referenced to the hydration status of the body. Studies on the validity of HM for the assessment of whole-body hydration status were conducted in the Appalachian State University, USA, on healthy young adults and on elderly subjects residing at an assisted living facility. The HM was able to track changes in total body water during periods of acute dehydration and rehydration in athletes and day-to-day and diurnal variability of hydration in elderly. Results of human studies indicate that HM has a potential to become an efficient tool for detecting abnormal changes in the body hydration status.

  20. Effect of whole-body vibration on muscle strength, spasticity, and ...

    African Journals Online (AJOL)

    CP) and is characterized by spasticity and muscle weakness of both lower limbs resulting in decreased walking ability. The purpose of this study was to evaluate the effect of whole body vibration (WBV) training on muscle strength, spasticity, and ...

  1. Calculation of effective dose in whole body in dependence of angle of collimator for photon fields

    International Nuclear Information System (INIS)

    Fuenzalida, M.; Varon, C.; Piriz, G.; Banguero, Y.; Lozano, E.; Mancilla, C.

    2011-01-01

    The objective of this work is to obtain quantifiable data of whole body effective dose for photons fields of 6 MV and 18 MV in function of the collimator angle of a Varian Clinac 21EX lineal accelerator. It has been made a variety of studies which investigate the form to reduce the dose in whole body with photons fields, specially over the potential risks and the influence of the collimator angle, as performed Stanthakis et al. [1] with the Monte Carlo method. As a result of this work, the values of whole body effective doses are higher with a 0 deg collimator than with a 90 deg collimator, and as the field size increases, the effective doses difference in whole body, between 0 deg and 90 deg collimator angle, for both energies, becomes smaller. (author)

  2. Calculation of effective dose in whole body in dependence of angle of collimator for photon fields

    Energy Technology Data Exchange (ETDEWEB)

    Fuenzalida, M. [Universidad de la Frontera, Temuco (Chile). Programa de Magister en Fisica Medica; Varon, C.; Piriz, G.; Banguero, Y.; Lozano, E.; Mancilla, C., E-mail: fisicamedica@incancer.c [Instituto Nacional del Cancer, Santiago (Chile). Unidad de Fisica Medica

    2011-07-01

    The objective of this work is to obtain quantifiable data of whole body effective dose for photons fields of 6 MV and 18 MV in function of the collimator angle of a Varian Clinac 21EX lineal accelerator. It has been made a variety of studies which investigate the form to reduce the dose in whole body with photons fields, specially over the potential risks and the influence of the collimator angle, as performed Stanthakis et al. [1] with the Monte Carlo method. As a result of this work, the values of whole body effective doses are higher with a 0 deg collimator than with a 90 deg collimator, and as the field size increases, the effective doses difference in whole body, between 0 deg and 90 deg collimator angle, for both energies, becomes smaller. (author)

  3. Radioisotope studies utilizing a low level whole body counter and clinical applications of activation analysis. Progress report. [Nuclear medicine research studies

    Energy Technology Data Exchange (ETDEWEB)

    Brill, A.B.

    1976-04-30

    Design modifications in radioisotope scanners are discussed. Studies on the radiation dose distribution in patients from /sup 90m/Tc-albumin microspheres in the lungs, /sup 59/Fe-citrate, /sup 131/I-hippuran in kidney transplants, and /sup 99m/Tc-pyrophosphates are reported. Data on the levels of fallout /sup 137/Co in normal individuals during 1975, as measured by whole-body counting, are reported. Results of studies on iodine metabolism in patients with hyperthyroidism and with T/sub 3/-thyrotoxicosis during /sup 131/I therapy with activities up to 17 mCi showed that the apparent volumes of distribution for different iodine compounds do not change appreciably during therapy in this dose range. Methods are described for measuring the content of Ca alone and Ca and P in bone tissues by transmission scanning using a /sup 252/Cf neutron source for activation of Ca and P. (CH)

  4. Distortion of calculated whole-body hematocrit during lower-body immersion in water.

    Science.gov (United States)

    Knight, D R; Santoro, T; Bondi, K R

    1986-11-01

    We found a difference between the venous hematocrits of immersed and nonimmersed arms during immersion of the lower body in cold water but not during a comparable exposure to warm water. Fourteen healthy men were exposed to three different experimental conditions: arm immersion, body immersion, and control. The men always sat upright while both upper extremities hung vertically at their sides. During arm immersion, one forearm was completely immersed for 30 min in either cold water (28 degrees C, n = 7) or warm water (38 degrees C, n = 7). This cold-warm water protocol was repeated on separate days for exposure to the remaining conditions of body immersion (immersion of 1 forearm and all tissues below the xiphoid process) and control (no immersion). Blood samples were simultaneously drawn from cannulated veins in both antecubital fossae. Hematocrit difference (Hct diff) was measured by subtracting the nonimmersed forearm's hematocrit (Hct dry) from the immersed forearm's hematocrit (Hct wet). Hct diff was approximately zero when the men were exposed to the control condition and body immersion in warm water. In the remaining conditions, Hct wet dropped below Hct dry (P less than 0.01, 3-way analysis of variance). The decrements of Hct diff showed there were differences between venous hematocrits in immersed and nonimmersed regions of the body, indicating that changes of the whole-body hematocrit cannot be calculated from a large-vessel hematocrit soon after immersing the lower body in cold water.

  5. Anisotropy of neutron sources of Neutron Metrology Laboratory, IRD, Brazil; Anisotropia de fontes de neutrons do Laboratorio de Metrologia de Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, A.C.F.; Silva, F.S.; Leite, S.P.; Creazolla, P.G; Patrão, K.C.S.; Fonseca, E.S. da; Fernandes, S.S.; Pereira, W.W., E-mail: Alexander.camargo@oi.com.br, E-mail: s.felippesouza@gmail.com, E-mail: karla@ird.gov.br, E-mail: walsan@ird.gov.br, E-mail: evaldo@ird.gov.br, E-mail: simonesilvafernandes@gmail.com, E-mail: prycyllacreazolla@gmail.com, E-mail: leitesprk@gmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Laboratorio Nacional de Metrologia; Fundação Técnico Educacional Souza Marques (FTESM), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    The anisotropy measurements have as main objective to define the emission of the radiation by different angles of an encapsulated neutron source. The measurements were performed using a Long Accuracy Counter (PLC) Detector in the Low Dispersion Room of the LNMRI / IRD with different neutron sources. Each measurement was made using a support for the source, emulated through an arduino system to rotate it. The carrier is marked with a variation of 5 °, ranging from 0 ° to 360 °, for the work in question only half, 0 ° to 180 ° is used for a total of nineteen steps. In this paper three sources of {sup 241}AmBe (α, n) 5.92 GBq (16 Ci) were used, neutron sources having the following dimensions: 105 mm in height and 31 mm in diameter. The PLC was positioned at a distance of 2 meters from the neutron source and has a radius of 15 cm for the detection area. The anisotropy factor of the {sup 241}AmBe source was 17%. The results in this work will focus mainly on the area of radioprotection and studies that will improve the process of routine measurements in laboratories and instrument calibrations. (author)

  6. Development of an Ergonomics Checklist for Investigation of Work-Related Whole-Body Disorders in Farming - AWBA: Agricultural Whole-Body Assessment.

    Science.gov (United States)

    Kong, Y K; Lee, S J; Lee, K S; Kim, G R; Kim, D M

    2015-10-01

    Researchers have been using various ergonomic tools to study occupational musculoskeletal diseases in industrial contexts. However, in agricultural work, where the work environment is poorer and the socio-psychological stress is high due to the high labor intensities of the industry, current research efforts have been scarce, and the number of available tools is small. In our preliminary studies, which focused on a limited number of body parts and other working elements, we developed separate evaluation tools for the upper and lower extremities. The current study was conducted to develop a whole-body ergonomic assessment tool for agricultural work that integrates the existing assessment tools for lower and upper extremities developed in the preliminary studies and to verify the relevance of the integrated assessment tool. To verify the relevance of the Agricultural Whole-Body Assessment (AWBA) tool, we selected 50 different postures that occur frequently in agricultural work. Our results showed that the AWBA-determined risk levels were similar to the subjective risk levels determined by experts. In addition, as the risk level increased, the average risk level increased to a similar extent. Moreover, the differences in risk levels between the AWBA and expert assessments were mostly smaller than the differences in risk levels between other assessment tools and the expert assessments in this study. In conclusion, the AWBA tool developed in this study was demonstrated to be appropriate for use as a tool for assessing various postures commonly assumed in agricultural work. Moreover, we believe that our verification of the assessment tools will contribute to the enhancement of the quality of activities designed to prevent and control work-related musculoskeletal diseases in other industries.

  7. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi

    1994-01-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of 99m Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, γ-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author)

  8. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1994-06-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of [sup 99m]Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, [gamma]-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author).

  9. Whole-body fat oxidation determined by graded exercise and indirect calorimetry: a role for muscle oxidative capacity?

    DEFF Research Database (Denmark)

    Nordby, P; Saltin, B; Helge, J W

    2006-01-01

    During whole-body exercise, peak fat oxidation occurs at a moderate intensity. This study investigated whole-body peak fat oxidation in untrained and trained subjects, and the presence of a relation between skeletal muscle oxidative enzyme activity and whole-body peak fat oxidation. Healthy male...... subjects were recruited and categorized into an untrained (N=8, VO(2max) 3.5+/-0.1 L/min) and a trained (N=8, VO(2max) 4.6+/-0.2 L/min) group. Subjects performed a graded exercise test commencing at 60 W for 8 min followed by 35 W increments every 3 min. On a separate day, muscle biopsies were obtained...... oxidation was determined. The body composition was determined by DEXA. Whole-body peak fat oxidation (250+/-25 and 462+/-33 mg/min) was higher (Ptrained compared with untrained subjects, respectively. Muscle...

  10. Estimation of internal exposure to 99Mo in nuclear medicine patients

    International Nuclear Information System (INIS)

    Dantas, B.M.; Silva, C.O.A. da; Dantas, A.L.A.; Lucena, E.A.; Souza, W.O.

    2008-01-01

    99m Tc is the most widely used radionuclide in nuclear medicine. It is obtained by elution of 99 Mo- 99m Tc generators. Depending on the quality of the generator and its integrity, 99 Mo might be extracted from the column during the elution process, becoming a radionuclidic impurity in the 99m Tc eluate. This fact would impart an undesired dose to the patients submitted to diagnostic procedures using 99m Tc. The aims of this work are: to evaluate the incorporation of 99 Mo as a radionuclidic impurity using in vivo and in vitro techniques; to estimate the internal effective doses in nuclear medicine patients and; to provide additional information about the metabolic behavior of molybdenum in humans. A methodology based on in vivo measurements and urine sampling was developed to determine retention and excretion patterns of molybdenum in the human body. In vivo measurements were performed in IRD whole body counter using a NaI(Tl) 8”x4” scintillation detector. The detector is located inside a shielded room with internal dimensions of 2.5 x 2.5 x 2.65 meters. In vitro analysis was based on the collection of urine samples from the patients and was performed in IRD bioassay laboratory using a High Purity Germanium (HPGe) detection system. Four patients have been monitored by in vivo and in vitro measurements showing detectable activities of 99 Mo in whole body and urine samples. Bioassay results were interpreted by using AIDE software version 6. Estimated values of 99 Mo incorporation were compared to predicted values based on the standard metabolic model of molybdenum established by the International Commission of Radiological Protection (ICRP). Internal effective doses were estimated in the order of micro sieverts per examination. Based on the data obtained in this work it is suggested to implement a routine quality control program of radionuclidic impurity of 99 Mo in 99m Tc eluates to be conducted by radiopharmacy laboratories of nuclear medicine centers. (author)

  11. The counter ion: expanding excipient functionality

    Directory of Open Access Journals (Sweden)

    Shireesh Apte

    2011-06-01

    Full Text Available Excipients have increasingly become 'enablers' of drug delivery and efficacy rather than passive bystanders. Advances in pharmaceutical technology have enabled the ability to deliver specific counter ions (in the form of the counter ion containing excipient and the API simultaneously to preselected targets in the body. This, coupled with a near universal mechanism of columbic interactions that determine the [API- counter ion] efficacy, can be harnessed to exploit this hitherto unavailable or unrecognized enabling mechanism. New excipients may be assembled by a near inexhaustible supply of different permutations of counter ions and their judicious use in specific situations could potentially drive a renaissance in excipient innovation (and drug delivery and efficacy despite regulatory stagnation.

  12. Comparison of the effects of whole-body cooling during fatiguing exercise in males and females.

    Science.gov (United States)

    Solianik, Rima; Skurvydas, Albertas; Pukėnas, Kazimieras; Brazaitis, Marius

    2015-08-01

    The effects of cold stress on exercise performance and fatigue have been thoroughly investigated only in males, and thus the general understanding of these effects relates only to males. The aim of this study was to determine whether whole-body cooling has different effects on performance during fatiguing exercise in males and females. Thirty-two subjects (18 males and 14 females) were exposed to acute cold stress by intermittent immersion in 14°C water until their rectal temperature reached 35.5°C or for a maximum of 170 min. Thermal responses and motor performance were monitored before and after whole-body cooling. Whole-body cooling decreased rectal, muscle and mean skin temperatures in all subjects (pCold stress decreased the fatigue index (FI) of a sustained 2-min maximal voluntary contraction (MVC) only in males (pbody cooling-induced decrease in the FI of a sustained MVC in males but not in females) supports the view of sex effects on performance during fatiguing exercise after whole-body cooling. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Cutaneous noradrenaline measured by microdialysis in complex regional pain syndrome during whole-body cooling and heating

    DEFF Research Database (Denmark)

    Terkelsen, Astrid Juhl; Gierthmühlen, Janne; Petersen, Lars J.

    2013-01-01

    and in healthy volunteers. Seven patients and nine controls completed whole-body cooling (sympathetic activation) and heating (sympathetic inhibition) induced by a whole-body thermal suit with simultaneous measurement of the skin temperature, skin blood flow, and release of dermal noradrenaline. CRPS pain...

  14. Whole-body and multispectral photoacoustic imaging of adult zebrafish

    Science.gov (United States)

    Huang, Na; Xi, Lei

    2016-10-01

    Zebrafish is a top vertebrate model to study developmental biology and genetics, and it is becoming increasingly popular for studying human diseases due to its high genome similarity to that of humans and the optical transparency in embryonic stages. However, it becomes difficult for pure optical imaging techniques to volumetric visualize the internal organs and structures of wild-type zebrafish in juvenile and adult stages with excellent resolution and penetration depth. Even with the establishment of mutant lines which remain transparent over the life cycle, it is still a challenge for pure optical imaging modalities to image the whole body of adult zebrafish with micro-scale resolution. However, the method called photoacoustic imaging that combines all the advantages of the optical imaging and ultrasonic imaging provides a new way to image the whole body of the zebrafish. In this work, we developed a non-invasive photoacoustic imaging system with optimized near-infrared illumination and cylindrical scanning to image the zebrafish. The lateral and axial resolution yield to 80 μm and 600 μm, respectively. Multispectral strategy with wavelengths from 690 nm to 930 nm was employed to image various organs inside the zebrafish. From the reconstructed images, most major organs and structures inside the body can be precisely imaged. Quantitative and statistical analysis of absorption for organs under illumination with different wavelengths were carried out.

  15. Disseminated cysticercosis in a child: whole-body MR diagnosis with the use of parallel imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Atin; Goenka, Ajit Harishkumar [All India Institute of Medical Sciences, Department of Radiology, New Delhi, Delhi (India); Choudhary, Anita; Sahu, Jitendra Kumar; Gulati, Sheffali [All India Institute of Medical Sciences, Department of Paediatrics, New Delhi, Delhi (India)

    2010-02-15

    Cysticercosis is a parasitic disease caused by infestation with the encysted larval stage of the pork tapeworm, Taenia solium. Disseminated cysticercosis is an exceptional expression of this disease characterized by high morbidity due to massive symptomatic parasite burden in the central nervous system, striated muscles, subcutaneous tissues and other organs. Less than 50 such cases have been reported worldwide, and fewer than 10 children. We report on the whole-body MR diagnosis of extensively disseminated cysticercosis in a child. The critical role of whole-body MR as a stand-alone modality in the diagnosis and management of this pleomorphic disease is highlighted. Whole-body MR diagnosis of an infectious disease is unique. (orig.)

  16. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    Energy Technology Data Exchange (ETDEWEB)

    Risco Norrlid, L. del (Swedish Radiation Safety Authority (Sweden)); Halldorsson, O. (Icelandic Radiation Safety Authority (Iceland)); Holm, S. (NM and PET at Copenhagen' s Univ. Hospital (Denmark)); Huikari, J. (Radiation and Nuclear Safety Authority (Finland)); Isaksson, M. (Goeteborg Univ., Dept. Radiation Physics Sahlgren Academy (Sweden)); Lind, B. (Norwegian Radiation Protection Authority (Norway)); Roed, H. (Danish State Institute for Radiation Protection (Denmark))

    2011-02-15

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  17. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    International Nuclear Information System (INIS)

    Risco Norrlid, L. del; Halldorsson, O.; Holm, S.; Huikari, J.; Isaksson, M.; Lind, B.; Roed, H.

    2011-02-01

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  18. Chemical radioprotection to bone marrow stem cells after whole body gamma irradiation to mice

    Energy Technology Data Exchange (ETDEWEB)

    Dey, J.; Dey, T.B.; Ganguly, S.K.; Nagpal, K.K.; Ghose, A.

    1988-11-01

    Protection to mice bone marrow stem cells has been noted as early as two days after whole body gamma ray exposure by prior treatment with combination of hydroxytryptophan (HT) and one of the two thiol drugs viz., aminoethylisothiuronium bromide hydrobromide (AET) (20 mg/kg body weight) and B-mercaptopropionylglicine (MPG). The levels of protection to bone marrow stem cells thus obtained have been compared to that obtained by treating with the optimum radioprotecting dose of AET (200 mg/kg body weight). The study reports the bone marrow stem cells status after two days of 3 Gy, 5 Gy and 10 Gy whole body gamma irradiation in relation to the mentioned radioprotecting treatments as studied by spleen colony forming method.

  19. Late biochemical changes in the rat lung after whole body irradiation

    International Nuclear Information System (INIS)

    Dancewicz, A.M.; Kubicka, T.

    1976-01-01

    Young Wistar rats were exposed to 650 R of whole body X-rays then sacrificed at different times after exposure up to one year, and various biochemical parameters in lung tissue were determined. Decrease in protein and elastin content and elevation in fibrinolytic and catheptic activity lasted during the whole observation period. In other parameters a fluctuation, mostly decrease followed by an increase, was seen only during the acute phase of radiation disease. (author)

  20. Whole body effective dose measurements in a fan beam bone mineral densitometer, Lunar expert

    Energy Technology Data Exchange (ETDEWEB)

    Sathiakumar, C.; Griffiths, M.; Cross, P.; Pocock, N.; Freund, J. [St Vincents Hospital, Sydney, NSW (Australia) Department of Nuclear Medicine; Kron, T.; Duggan, L. [Newcastle Mater Misericordiae Hospital, Newcastle, NSW (Australia). Department of Radiation Oncology; Holley, L. [University of Technology, Sydney, NSW (Australia). Department of Health Services

    1998-06-01

    Full text: The most recent generation of DXA machines employ a fan beam geometry and high resolution imaging detector, resulting in decreased scanning time and increased image resolution compared to previous rectilinear scanners, but with higher radiation burden to the patient because of an increasing number of bone mineral density scans, it was felt that independent evaluation of the radiation dose was necessary. The whole body effective dose for an AP lumbar spine scan and femur scan using the EXPERT bone densitometer was calculated for the fast and turbo scanning modes, using thermoluminescence dosimetry (TLD). A method was developed to determine the absorbed dose of the irradiated volume of an organ by summing the dose for each of the coronal areas, which results in a volume dose. The Whole Body Effective dose for AP lumbar spine fast scanning mode is 84.1 {mu}Sv and turbo scanning mode is 56.4 {mu}Sv. The Whole Body Effective dose for femur fast scanning mode is 6.6 {mu}Sv and turbo scanning mode is 4.2 {mu}Sv, with no ovary exposure. A theoretical method has been developed to calculate the organ dose from which whole body effective dose was calculated

  1. Whole-Body versus Local DXA-Scan for the Diagnosis of Osteoporosis in COPD Patients

    Directory of Open Access Journals (Sweden)

    Lidwien Graat-Verboom

    2010-01-01

    Full Text Available Background. Osteoporosis is an extrapulmonary effect of chronic obstructive pulmonary disease (COPD. Diagnosis of osteoporosis is based on BMD measured by DXA-scan. The best location for BMD measurement in COPD has not been determined. Aim of this study was to assess whole-body BMD and BMD of the hip and lumbar spine (local DXA in COPD patients and compare the prevalence of osteoporosis at these locations. Methods. Whole body as well as local DXA-scan were made in 168 COPD patients entering pulmonary rehabilitation. Patient-relevant characteristics were assessed. Prevalence of osteoporosis was determined. Characteristics of patients without osteoporosis were compared to patients with osteoporosis on local DXA. Results. A higher prevalence of osteoporosis was found using local DXA compared to whole-body DXA (39% versus 21%. One quarter of patients without osteoporosis on whole body-DXA did have osteoporosis on local DXA. Significant differences in patient characteristics between patients without osteoporosis based on both DXA measurements and patients with osteoporosis based on local DXA only were found. Conclusions. DXA of the hip and lumbar spine should be made to assess bone mineral density in COPD patients. The lowest T-score of these locations should be used to diagnose osteoporosis.

  2. The effect of whole body vibration exercise on muscle activation ...

    African Journals Online (AJOL)

    African Journal for Physical Activity and Health Sciences ... The effect of whole body vibration exercise (WBV) on muscle activation has recently been a topic for discussion amongst some researchers. ... Participants then performed two different exercises: standing calf raises and prone bridging, without and with WBV.

  3. Corrections of the whole body counting for various measurement geometries

    International Nuclear Information System (INIS)

    Fueloep, M.; Ragan, P.; Lahham, A.

    1996-01-01

    A simple method was suggested for making corrections during the calibration of HPGe detectors employed for the whole-body counting of humans ranging from infants to adults. The results obtained by calculations were verified by using phantoms. (P.A.). 1 tab., 5 figs., 3 refs

  4. Evaluation of whole-body MR to CT deformable image registration

    NARCIS (Netherlands)

    Akbarzadeh, A.; Gutierrez, D.; Baskin, A.; Ay, M. R.; Ahmadian, A.; Alam, N. Riahi; Loevblad, K. O.; Zaidi, H.

    2013-01-01

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based

  5. Linear Representation of Emotions in Whole Persons by Combining Facial and Bodily Expressions in the Extrastriate Body Area

    Science.gov (United States)

    Yang, Xiaoli; Xu, Junhai; Cao, Linjing; Li, Xianglin; Wang, Peiyuan; Wang, Bin; Liu, Baolin

    2018-01-01

    Our human brain can rapidly and effortlessly perceive a person’s emotional state by integrating the isolated emotional faces and bodies into a whole. Behavioral studies have suggested that the human brain encodes whole persons in a holistic rather than part-based manner. Neuroimaging studies have also shown that body-selective areas prefer whole persons to the sum of their parts. The body-selective areas played a crucial role in representing the relationships between emotions expressed by different parts. However, it remains unclear in which regions the perception of whole persons is represented by a combination of faces and bodies, and to what extent the combination can be influenced by the whole person’s emotions. In the present study, functional magnetic resonance imaging data were collected when participants performed an emotion distinction task. Multi-voxel pattern analysis was conducted to examine how the whole person-evoked responses were associated with the face- and body-evoked responses in several specific brain areas. We found that in the extrastriate body area (EBA), the whole person patterns were most closely correlated with weighted sums of face and body patterns, using different weights for happy expressions but equal weights for angry and fearful ones. These results were unique for the EBA. Our findings tentatively support the idea that the whole person patterns are represented in a part-based manner in the EBA, and modulated by emotions. These data will further our understanding of the neural mechanism underlying perceiving emotional persons. PMID:29375348

  6. Improved rectilinear scanning device for the whole body

    International Nuclear Information System (INIS)

    Berninger, W.H.

    1975-01-01

    A rectilinear scanning device for whole-body counting is described in which the spacial resolution is considerably improved upon by using photomultipliers with spherically curved photocathodes. By this measure, the distinct non-linearity between the output signals of the phototubes and the actual position of the scintillation in the scintillation crystal, as observed in plane photocathodes, is removed. The distances between the photomultipliers and the scintillation crystal can thus be kept very small whereby an improved statistic and lower noise can be obtained. Furthermore, thicker crystals can be used whereby the efficiency in the determination of higher energies is increased. The electronic signal processing to the reproduction of the nuclide distribution in the body is described in detail. (ORU/LH) [de

  7. Whole body measurements of sodium turnover in offspring of patients with sustained essential hypertension

    International Nuclear Information System (INIS)

    Henningsen, N.C.; Ohlsson, O.; Mattson, S.; Nosslin, B.; Lund Univ.; Lund Univ.

    1982-01-01

    The elimination rate (percent per day) of injected 22 Na using a whole body measurement technique was significantly lower (26%, 5.8 +- 1.5) in normotensive of borderline hypertensive offspring of essential hypertensive patients than in 15 age- and sex-matched, normotensive controls (7.3 +- 1.0). There were no significant differences in exchangeable sodium, whole body potassium or in the urinary exeretion of sodium, potassium and creatinine. The basis for the difference in turnover rate during weck 1 is probably an alteration in the cellular handling of sodium (i.e. increased intracellular sodium) in the still normotensive offspring of patients with essential hypertension. The long-term (more than 100 days) whole body retention of 22 Na was found to be only 0.1% of that injected, which justifies the use of the method on larger population groups. (orig.)

  8. Effect of whole-body cryotherapy on the rheological parameters of blood in older women with spondyloarthrosis.

    Science.gov (United States)

    Kulis, Aleksandra; Misiorek, Anna; Marchewka, Jakub; Głodzik, Jacek; Teległów, Aneta; Dąbrowski, Zbigniew; Marchewka, Anna

    2017-01-01

    Cryotherapy is a physiotherapy method used to treat back pain in older persons. This study aims to evaluate the changes in the rheological parameters of blood in older women with spondyloarthrosis, who underwent whole-body cryotherapy. The experimental group comprised 69 older women with lumbar spondyloarthrosis, aged between 65 and 70 years. Due to the methodology of the procedure, the experimental group was randomly divided into three groups. Each group underwent two weeks of different types of physiotherapy: only whole-body cryotherapy (22 women); only kinesitherapy (23 women); and both cryotherapy and kinesitherapy (24 women). The control group comprised 25 women who did not undergo any form of therapy. The evaluation of the rheological properties of the blood encompassed measurements of the plasma viscosity, the erythrocyte elongation and aggregation indices, and the level of fibrinogen. The conducted rheological tests revealed a significant decrease in the erythrocyte elasticity and aggregation indices only in the group of women who had undergone both whole-body cryotherapy and kinesitherapy. Applying whole-body cryotherapy to older women with spondyloarthrosis decreases the elasticity of erythrocytes and, despite favourable changes in the aggregation parameters, problems with perfusion may still appear. For this reason, the benefit of using whole-body cryotherapy in these persons is debatable.

  9. Validation of Experimental whole-body SAR Assessment Method in a Complex Indoor Environment

    DEFF Research Database (Denmark)

    Bamba, Aliou; Joseph, Wout; Vermeeren, Gunter

    2012-01-01

    Assessing experimentally the whole-body specific absorption rate (SARwb) in a complex indoor environment is very challenging. An experimental method based on room electromagnetics theory (accounting only the Line-Of-Sight as specular path) to assess the whole-body SAR is validated by numerical...... of the proposed method is that it allows discarding the computation burden because it does not use any discretizations. Results show good agreement between measurement and computation at 2.8 GHz, as long as the plane wave assumption is valid, i.e., for high distances from the transmitter. Relative deviations 0...

  10. The clinical value of "9"9Tc"m-MDP whole body bone imaging in diagnosing bone metastasis of lung cancer

    International Nuclear Information System (INIS)

    Zhao Yigang; Gou Zhengxing

    2016-01-01

    Objective: To discuss the clinical value of whole body bone imaging on lung cancer bone metastases diagnosis, so as to evaluate the staging of lung cancer patients. Methods: A total of 113 cases of patients diagnosed with lung cancer received whole body imaging, alkaline phosphatase and blood calcium examination. Bone metastasis probability of lung cancer was assessed based on different pathological types. Accuracy rates of bone metastases was compared by whole body bone imaging and suspicious bone metastasis factors (Including one or several items in ostalgia, alkaline phosphatase rising and hypercalcemia). Results The occurrence rate of lung cancer bone metastasis is 36.7%, and the bone metastasis occurrence rate of adenocarcinoma of lung is higher than that of squamous cell lung carcinoma (P < 0.01). Whole body Imaging diagnose of lung cancer bone metastases had sensitivity (92.7%), specificity (83.2%) and accuracy (85.7%). Conclusion: "9"9Tc"m-MDP whole body imaging is a highly sensitive tool to review whole body bone. Lung cancer patients are recommended to receive routine whole body bone imaging. (authors)

  11. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation.

    Science.gov (United States)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (~15-20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate Ki and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final Ki parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion study

  12. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation

    International Nuclear Information System (INIS)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-01-01

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (∼15–20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate K i and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final K i parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion

  13. Interventions for chronic low back pain: whole body vibration and ...

    African Journals Online (AJOL)

    Objectives. This study explored, described and compared the effects of whole body vibration (WBV) therapy and conventional spinal stabilisation exercises in persons with chronic low back pain (CLBP). Design. A non-randomised sampling technique was used to delineate the base of volunteers gathered by a combination ...

  14. Dependence of a whole body counting efficiency on body size and composition

    International Nuclear Information System (INIS)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R.

    2001-01-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  15. Dependence of a whole body counting efficiency on body size and composition

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2001-07-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  16. Quality control of total alpha and beta activity analysis in water using the Proportional Counter of Gaseous Flux technique; Controle de qualidade das análises de atividades alfa e beta total em água pela técnica do Contador Proporcional de Fluxo Gasoso

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Alberto P.; Bastos, Thiago M.R.; Santos, Thiago O.; Filho, Crescêncio A.S.; França, Elvis J. de, E-mail: albertopereiran@gmail.com, E-mail: thiagomrbastos@gmail.com, E-mail: thiago_cbufpe@yahoo.com.br, E-mail: candrade@cnen.gov.br, E-mail: ejfranca@cnen.gov.br [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2017-07-01

    The analytical capacity of the CRCN (Centro Regional de Ciências Nucleares do Nordeste) for quantification of total alpha and beta concentrations in water samples using the Proportional Counter of Gaseous Flux is presented. To demonstrate the traceability of the results, the National Intercomparison Program (PNI) samples were used, promoted by the Institute of Radioprotection and Dosimetry (IRD) from which the Regional Nuclear Science Center of the Northeast (CRCN-NE) participates since 2011. The results reported to the PNI demonstrate the analytical capacity of the CRCN to detect the emission of alpha and beta radioactivities in water within the potability standards in analytical detection of quantification in radioactivity by the technique of the Proportional Flow Counter.

  17. Response of irradiated diet fed rats to whole body X irradiation

    International Nuclear Information System (INIS)

    Hasan, S.S.; Kushwaha, A.K.S.

    1985-01-01

    The response to whole body X irradiation has been studied in the brain of rats fed both on a normal diet (consisting of equal parts of wheat and gram flour) and on a low protein irradiated diet (consisting of a part of normal diet and three parts of wheat). The activity of enzymes related to the glucose metabolism (glucose 6-phosphate dehydrogenase and fructose diphosphate aldolase) is reduced, while that of peroxidant enzymes (catalase and lipid peroxidase) increased in the brain of rats that received a diet poor in proteins and irradiated diets (normal or hypoproteic). DNA and RNA levels and protein content show a significant reduction in the brain of rats with hypoproteic and irradiated diets. The total body irradiation causes serious alterations in the brain in animals with a hypoproteic malnutritions due both to a low protein and an irradiated diet. The brain of rats fed on a low protein and irradiated diet exhibits after whole body irradiation damages more severe than those in rats fed on a normal irradiated diet

  18. Trial making of a positive drawing phantom and its application to whole-body imaging devices

    International Nuclear Information System (INIS)

    Saegusa, Kenji; Arimizu, Noboru; Nakata, Tsuneo; Toyama, Haruo; Shiina, Isamu.

    1980-01-01

    In whole-body RI imaging, there are more instances of the positive pictures detecting the radioisotopes accumulating in morbid positions, such as Tc-99m bone scanning. The phantoms used to mutually compare RI imaging devices and to test their performance employ negative drawing targets embedded rather than positive ones. A simple positive drawing phantom has been made for trial, and applying this to whole-body scanning devices, the performance and the target drawing ability under different scanning conditions were comparatively examined. Though similar to Rollo's phantom, the phantom made for positive drawing uses acryl plate for its outer structure and target portions. The positive targets are cylindrical, and the diameters are 2, 4, 6, 8, 10, and 20 mm, and the subject contrasts are 5, 2, 1, 0.5 and 0.2. The aqueous solution of Tc-99m of about 2 mCi was injected into the phantom, and this was scanned with a whole-body camera and a multi-detector type whole-body scanner. With the phantom pictures close to actual clinical condition, the positive drawing phantom is conveniently capable of comparing the respective imaging devices for intended purposes. (J.P.N.)

  19. Measurement of whole-body human centers of gravity and moments of inertia.

    Science.gov (United States)

    Albery, C B; Schultz, R B; Bjorn, V S

    1998-06-01

    With the inclusion of women in combat aircraft, the question of safe ejection seat operation has been raised. The potential expanded population of combat pilots would include both smaller and larger ejection seat occupants, which could significantly affect seat performance. The method developed to measure human whole-body CG and MOI used a scale, a knife edge balance, and an inverted torsional pendulum. Subjects' moments of inertia were measured along six different axes. The inertia tensor was calculated from these values, and principal moments of inertia were then derived. Thirty-eight antropometric measurements were also taken for each subject to provide a means for direct correlation of inertial properties to body dimensions and for modeling purposes. Data collected in this study has been used to validate whole-body mass properties predictions. In addition, data will be used to improve Air Force and Navy ejection seat trajectory models for the expanded population.

  20. Bilateral IFBA/IRD comparison in diagnostic radiology: Air kerma in RQR series; Comparação bilateral IFBA/IRD em radiologia diagnóstica - Kerma no ar nas qualidades RQR

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, E.M.; Navarro, M.V.T.; Garcia, I.F.M.; Ferreira, M.J., E-mail: ematosmacedo@gmail.com [Instituto Federal da Bahia (Labprosaud/IFBA), Savador, BA (Brazil). Lab. de Produtos para Saúde; Peixoto, J.G.P. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Two interlaboratory comparisons were conducted, in 2016 and 2017, by the IRD and Labprosaud/IFBA calibration laboratories, creating subsidies to improve the quality and standardization of the calibration services performed by both. The comparisons were performed in terms of air kerma for RQR series radiation qualities, according IEC 61267. Substitution method was used, based on TRS 457 recommendations and Technical Protocol to Bilateral Comparison of Calibration Brazilian Network Laboratories in Diagnostic Radiology (2015). Results varying between 0.994 and 1.006 on first comparison, and between 0.986 and 1.009 on second one, were declared satisfactory. (author)

  1. A critical evalution of 24 hours whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Bessent, R.G.; Scullion, J.E.; Cuthbert, G.F.

    1982-01-01

    In previous studies we have found that 24 hour whole-body retention (WBR) of diphosphonate is a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r = 0.998, p < 0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. The net whole-body count of a phantom representing the 24 hour whole-body distribution of tracer was 98% of that of a uniform phantom. Ten subjects, counted twice within a few minutes to study the effect of repositioning showed a mean difference between counts of only 0.8%. For eleven subjects with traumatic fractures it was found that 9 had normal values for WBR, while 2 had minimally elevated results. For twenty patients with renal disease but no apparent skeletal disease a significant correlation between serum creatinine and WBR was found (r = 0.72, p<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/l. It is suggested that WBR measurement is accurate and the technique is highly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is in the normal range then an elevated WBR result can be assumed to reflect increased skeletal metabolism without further concern as to renal function. (Author)

  2. Whole-body voxel phantoms of paediatric patients—UF Series B

    Science.gov (United States)

    Lee, Choonik; Lee, Choonsik; Williams, Jonathan L.; Bolch, Wesley E.

    2006-09-01

    Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult (UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm × 0.86 mm × 3.0 mm, 0.90 mm × 0.90 mm × 5.0 mm, 1.16 mm × 1.16 mm × 6.0 mm, 0.94 mm × 0.94 mm × 6.00 mm and 1.18 mm × 1.18 mm × 6.72 mm, respectively.

  3. Effect of whole body cryotherapy interventions on health-related quality of life in fibromyalgia patients: A randomized controlled trial.

    Science.gov (United States)

    Vitenet, M; Tubez, F; Marreiro, A; Polidori, G; Taiar, R; Legrand, F; Boyer, F C

    2018-02-01

    Although fibromyalgia syndrome (SFM) affects 2-4 percent of adults, research has not identified a preferred therapeutic option for patients worldwide yet. Based on recent findings, it can be expected that whole body cryotherapy can improve health-reported quality of life by alleviating the symptoms of musculoskeletal pain and fatigue. Our aim was to determine whether whole body cryotherapy only can result in improved perceived health and quality of life in fibromyalgia patients. 24 patients with fibromyalgia diagnosis were randomized into 2 groups (n=11 in the whole body cryotherapy group, n=13 in the control group). In the whole body cryotherapy group, 10 sessions of whole body cryotherapy were performed (in addition to usual care) in a standard cryotherapy room over a duration of 8days. Subjects in the control group did not change anything in their everyday activities. Quality of life was assessed just before and one month after treatment. Compared with the control group, patients in the whole body cryotherapy group reported significantly improved for health-reported quality of life. These effects lasted for at least one month following intervention. Based on these findings, whole body cryotherapy can be recommended as an effective clinically adjuvant approach in the improvement of health-related quality of life in fibromyalgia patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Histopathological studies show protective efficacy of Hippophae leaf extract against damage to jejunum in whole body 60Co-a-irradiated mice

    International Nuclear Information System (INIS)

    Gupta, Manish; Prasad, Jagdish; Madhu Bala

    2012-01-01

    Background: Ionizing radiation affect living tissue by causing majority of in vivo damage by free radical production. Earlier we reported that our preparation from Hippophae leaf offered survival benefit to >90% mice population which was whole body irradiated ( 60 Co-a-rays, 10 Gy). Objective: This study was planned to examine the protective effects of our drug (from Hippophae leaf) on ( 60 Co-a-ray induced oxidative damage and histopathological changes in jejunum. Methods: Around 2 months old adult male Strain 'A' mice were irradiated (10 Gy). Drug was administered intraperitoneally (-30 mm.). Histological parameters were studied after staining the sections with hematoxylin and eosin. Malondialdehyde formation (index of lipid peroxidation), alkaline phosphatase activity, and total thiol content were determined by biochemical techniques. The data was obtained at different time interval upto 30 days. Results: Biochemical studies showed that in comparison to the untreated controls, in the irradiated (10 Gy) mice, there was significant increase in the alkaline phosphatase activity and level of malondialdehyde whereas decrease in total thiol content within 2 days. Histological studies showed that whole body irradiation (10 Gy), damaged the jejunam crypt cells and decreased the villi height within 2 days. Intra-peritoneal administration of drug, 30 mm prior to irradiation, protected the crypt cells and villi height, countered the radiation induced increase in alkaline phosphatase activity and lipid peroxidation and values were comparable to the level of control in 30 days. Conclusions: These biochemical and histopathological studies suggested that our drug can offer effective radioprotection against the oxidative damage to jejunum in vivo. (author)

  5. Effect of whole body irradiation on different tissues

    International Nuclear Information System (INIS)

    Casati, V.; Nardino, A.; Tomassi, I.; Becciolini, A.; Rizzi, M.; Martelli, T.

    1979-01-01

    The uptake and elimination of 14 C leucine were analysed in controls and in rats irradiated 2 h before injection with 8 Gy whole-body irradiation. Plasma, small intestine, kidney and skin were assayed after homogenization for TCA soluble and insoluble activity curves. In highly differentiated tissues with poor proliferative activity and low protein turnover, the uptake and elimination of the tracer did not appear to be affected by irradiation. In the small intestine differences between control and irradiated animals seemed significant. (Auth.)

  6. Effective dose estimation in whole-body multislice CT in paediatric trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Robin D.; Saueressig, Ulrich; Kotter, Elmar; Langer, Mathias; Bley, Thorsten A. [University Hospital, Department of Radiology, Freiburg im Breisgau (Germany); Strohm, Peter C.; Zwingmann, Joern; Suedkamp, Norbert P. [University Hospital, Department of Orthopaedic and Trauma Surgery, Freiburg im Breisgau (Germany); Uhl, Markus [University Hospital, Department of Radiology, Section of Paediatric Radiology, Freiburg im Breisgau (Germany)

    2009-03-15

    The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body MSCT provides the clinicians with relevant information to initiate life-saving therapy. Radiologists should use special paediatric protocols that include dose-saving mechanisms to keep the effective dose as low as possible. Further studies are needed to examine and advance dose-saving strategies in MSCT, especially in children. (orig.)

  7. Age and sex dependence of body potassium based on studies of 40K under Indian conditions

    International Nuclear Information System (INIS)

    Ranganathan, S.; Someswara Rao, M.; Nagaratnam, A.; Mishra, U.C.

    2002-01-01

    Potassium plays an important role in human life 40 K is a naturally occurring radioisotope of potassium (K) with an abundance of 0.0118%. The measurement of body 40 K in a whole-body counter (WBC) provides a sensitive technique to estimate the total body potassium (TBK). Information on TBK of Indians with age and sex is scanty. Therefore, a systematic study was taken up to generate this information using a sensitive WBC

  8. Effects of whole-body cryotherapy on recovery after hamstring damaging exercise: a crossover study.

    Science.gov (United States)

    Fonda, B; Sarabon, N

    2013-10-01

    The purpose of this study was to examine the effects of whole-body cryotherapy (WBC) on biochemical, pain, and performance parameters during the 5-day recovery period after damaging exercise for hamstrings. Participants completed a bout of damaging exercise for the hamstring muscles on two separate occasions (control and experimental condition) separated by 10 weeks. During the control condition, subjects received no treatment after the damaging exercise. The experimental condition consisted of WBC everyday during the recovery period. WBC included single 3-min daily exposures to low temperatures (-140 to -19 °C) in the cryo-cabin. During the recovery period, subjects were tested for biochemical markers, perceived pain sensation, and physical performance (squat jump, counter movement jump, maximal isometric torque production, and maximally explosive isometric torque production). Majority of the observed variables showed statistically significant time effects (P < 0.05) in control group, which indicates the presence of muscle damage. Significant interaction between the control and WBC condition was evident for the rate of torque development (P < 0.05). Pain measures substantially differed between the WBC and the control condition after the exercise. Results of this study are not completely supportive of the use of WBC for recovery enhancement after strenuous training. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L. [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Bamberg, Fabian [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); University Hospital Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lochner, Elena [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); Findeisen, Hannes M. [University Hospital Muenster, Department of Cardiology and Angiology, Muenster (Germany); Parhofer, Klaus G. [Ludwig Maximilians University, Klinikum Grosshadern, Department of Internal Medicine II, Munich (Germany); Schoenberg, Stefan O. [University Medical Center Mannheim, Department of Clinical Radiology and Nuclear Medicine, Mannheim (Germany)

    2016-05-15

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  10. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    International Nuclear Information System (INIS)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L.; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M.; Parhofer, Klaus G.; Schoenberg, Stefan O.

    2016-01-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  11. Back disorders in crane operators exposed to whole-body vibration

    NARCIS (Netherlands)

    Bongers, P. M.; Boshuizen, H. C.; Hulshof, C. T.; KOEMEESTER, A. P.

    1988-01-01

    In The Netherlands so far little research has been carried out to investigate the health effects of exposure to whole-body vibration at work. In a retrospective (10-year) follow-up study, the incidence of permanent work disabilities in crane operators exposed to vibration was compared to that of a

  12. Can segmental model reductions quantify whole-body balance accurately during dynamic activities?

    Science.gov (United States)

    Jamkrajang, Parunchaya; Robinson, Mark A; Limroongreungrat, Weerawat; Vanrenterghem, Jos

    2017-07-01

    When investigating whole-body balance in dynamic tasks, adequately tracking the whole-body centre of mass (CoM) or derivatives such as the extrapolated centre of mass (XCoM) can be crucial but add considerable measurement efforts. The aim of this study was to investigate whether reduced kinematic models can still provide adequate CoM and XCoM representations during dynamic sporting tasks. Seventeen healthy recreationally active subjects (14 males and 3 females; age, 24.9±3.2years; height, 177.3±6.9cm; body mass 72.6±7.0kg) participated in this study. Participants completed three dynamic movements, jumping, kicking, and overarm throwing. Marker-based kinematic data were collected with 10 optoelectronic cameras at 250Hz (Oqus Qualisys, Gothenburg, Sweden). The differences between (X)CoM from a full-body model (gold standard) and (X)CoM representations based on six selected model reductions were evaluated using a Bland-Altman approach. A threshold difference was set at ±2cm to help the reader interpret which model can still provide an acceptable (X)CoM representation. Antero-posterior and medio-lateral displacement profiles of the CoM representation based on lower limbs, trunk and upper limbs showed strong agreement, slightly reduced for lower limbs and trunk only. Representations based on lower limbs only showed less strong agreement, particularly for XCoM in kicking. Overall, our results provide justification of the use of certain model reductions for specific needs, saving measurement effort whilst limiting the error of tracking (X)CoM trajectories in the context of whole-body balance investigation. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Calculation of the correction factors for the primary standard of kerma in the air at the LNMRI-IRD, Rio de Janeiro, Brazil; Calculo de fatores de correcao para o padrao primario em kerma no ar do LNMRI-IRD, Rio de Janeiro, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cosme Norival Mello da, E-mail: cosme@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)

    2009-07-01

    In order to determine the primary standardization in terms of kerma in the air, a graphite ionization chamber is used for calculation some correction factors. A program was elaborated, using the Monte Carlo Penelope for simulate the CC01-110 at the LNMRI/IRD, Rio de Janeiro, Brazil

  14. Impact of whole-body rehabilitation in patients receiving chronic mechanical ventilation.

    Science.gov (United States)

    Martin, Ubaldo J; Hincapie, Luis; Nimchuk, Mark; Gaughan, John; Criner, Gerard J

    2005-10-01

    To evaluate the prevalence and magnitude of weakness in patients receiving chronic mechanical ventilation and the impact of providing aggressive whole-body rehabilitation on conventional weaning variables, muscle strength, and overall functional status. Retrospective analysis of 49 consecutive patients. Multidisciplinary ventilatory rehabilitation unit in an academic medical center. Forty-nine consecutive chronic ventilator-dependent patients referred to a tertiary care hospital ventilator rehabilitation unit. None. Patients were 58 +/- 7 yrs old with multiple etiologies for respiratory failure. On admission, all patients were bedridden and had severe weakness of upper and lower extremities measured by a 5-point muscle strength score and a 7-point Functional Independence Measurement. Postrehabilitation, patients had increases in upper and lower extremity strength (p respiratory muscle training with an improvement in strength, weaning outcome, and functional status. Whole-body rehabilitation should be considered a significant component of their therapy.

  15. Acute interleukin-6 administration does not impair muscle glucose uptake or whole-body glucose disposal in healthy humans

    DEFF Research Database (Denmark)

    Steensberg, Adam; Fischer, Christian P; Sacchetti, Massimo

    2003-01-01

    adrenaline (epinephrine). IL-6 infusion, irrespective of dose, did not result in any changes to endogenous glucose production, whole-body glucose disposal or leg- glucose uptake. These data demonstrate that acute IL-6 administration does not impair whole-body glucose disposal, net leg-glucose uptake......The cytokine interleukin (IL)-6 has recently been linked with type 2 diabetes mellitus and has been suggested to affect glucose metabolism. To determine whether acute IL-6 administration affects whole-body glucose kinetics or muscle glucose uptake, 18 healthy young men were assigned to one of three...... the cessation of infusion (recovery) to determine endogenous glucose production and whole-body glucose disposal. Infusion with HiIL-6 and LoIL-6 resulted in a marked (P

  16. Whole-body counting in the Marshall Islands

    International Nuclear Information System (INIS)

    Sun, L.C.; Clinton, J.; Kaplan, E.; Meinhold, C.B.

    1991-01-01

    In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish 137 Cesium body contents among the Enewetak, Rongelap and Utirik populations. 137 Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. 137 Cs body burdens tended to increase with age for both sexes, and were higher in males. The average 137 Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22±4 μSv. For Utirik, the dose was 33± 3 μSv. Since 1985 the Rongelap people have been self-exiled to Mejatto. Biological elimination should have reduced their dose to virtually zero, and the measured dose was 2±2 μSv. If they had remained on Rongelap Island, the calculated dose would have been 99 μSv, which is about one-third of the background dose. 7 refs., 1 tab

  17. Local forearm and whole-body respiratory quotient in humans after an oral glucose load

    DEFF Research Database (Denmark)

    Simonsen, L; Bülow, J; Madsen, J

    1993-01-01

    the glucose load and had not returned to baseline level at the end of the experiment. Whole-body respiratory quotient (RQ) was, on average, 0.80 (SD 0.05) in the baseline condition and increased to a maximum of 0.91 (0.03) and then decreased to baseline level at the end of the experiment. The local forearm.......17) to 0.63 (0.17) 30 min after the glucose load (P glucose load RQ increased to a maximum level at 0.95 (0.22) and decreased then gradually to baseline level. The experiments emphasize several methodological problems in the measurement of local forearm RQ. The whole-body RQ......The effects of an oral glucose load of 75 g on the local forearm and whole-body energy thermogenesis were measured in normal subjects during the 4 h after the glucose intake. Simultaneous assessment of substrate metabolism in the forearm was performed. Energy expenditure (EE) increased after...

  18. Whole-body cryotherapy: empirical evidence and theoretical perspectives

    Directory of Open Access Journals (Sweden)

    Bleakley CM

    2014-03-01

    Full Text Available Chris M Bleakley,1 François Bieuzen,2 Gareth W Davison,1 Joseph T Costello3 1Sport and Exercise Science Research Institute, Faculty of Life and Health Sciences, University of Ulster, Newtownabbey, Northern Ireland; 2Research Department, Laboratory of Sport, Expertise and Performance, French National Institute of Sport (INSEP, Paris, France; 3School of Exercise and Nutrition Sciences and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia Abstract: Whole-body cryotherapy (WBC involves short exposures to air temperatures below –100°C. WBC is increasingly accessible to athletes, and is purported to enhance recovery after exercise and facilitate rehabilitation postinjury. Our objective was to review the efficacy and effectiveness of WBC using empirical evidence from controlled trials. We found ten relevant reports; the majority were based on small numbers of active athletes aged less than 35 years. Although WBC produces a large temperature gradient for tissue cooling, the relatively poor thermal conductivity of air prevents significant subcutaneous and core body cooling. There is weak evidence from controlled studies that WBC enhances antioxidant capacity and parasympathetic reactivation, and alters inflammatory pathways relevant to sports recovery. A series of small randomized studies found WBC offers improvements in subjective recovery and muscle soreness following metabolic or mechanical overload, but little benefit towards functional recovery. There is evidence from one study only that WBC may assist rehabilitation for adhesive capsulitis of the shoulder. There were no adverse events associated with WBC; however, studies did not seem to undertake active surveillance of predefined adverse events. Until further research is available, athletes should remain cognizant that less expensive modes of cryotherapy, such as local ice-pack application or cold-water immersion, offer comparable

  19. Amino acid metabolism and whole-body protein turnover in lambs ...

    African Journals Online (AJOL)

    The effect of protein supplementation of a wheat straw diet on the metabolism of lysine, leucine, methionine and urea, and on whole-body protein turnover rate was investigated in lambs. The metabolism of lysine and leucine is reported elsewhere (Cronje et aI., 1992); in this paper methionine metabolism is discussed, and ...

  20. Short-term lower-body plyometric training improves whole body BMC, bone metabolic markers, and physical fitness in early pubertal male basketball players.

    Science.gov (United States)

    Zribi, Anis; Zouch, Mohamed; Chaari, Hamada; Bouajina, Elyes; Ben Nasr, Hela; Zaouali, Monia; Tabka, Zouhair

    2014-02-01

    The effects of a 9-week lower-body plyometric training program on bone mass, bone markers and physical fitness was examined in 51 early pubertal male basketball players divided randomly into a plyometric group (PG: 25 participants) and a control group (CG: 26 participants). Areal bone mineral density (aBMD), bone mineral content (BMC), and bone area (BA) in the whole body, L2-L4 vertebrae, and in total hip, serum levels of osteocalcin (Oc) and C-terminal telopeptide fragment of Type I collagen (CTx), jump, sprint and power abilities were assessed at baseline and 9 weeks. Group comparisons were done by independent student's t-test between means and analyses of (ANOVA) and covariance (ANCOVA), adjusting for baseline values. PG experienced a significant increase in Oc (p BMC and BA in any measured site, except in whole body BMC of the PG. A positive correlation was observed between percentage increase (Δ%) of physical fitness and those of (Oc) for the PG. In summary, biweekly sessions of lower body plyometric training program were successful for improving whole body BMC, bone formation marker (Oc) and physical fitness in early pubertal male basketball players.

  1. Evaluation of internal exposure of nuclear medicine staff through in vivo and in vitro bioassay techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lucena, E.A.; Araujo, F.; Sousa, W.O.; Dantas, A.L.A.; Dantas, B.M. [Instituto de Radioprotecao e Dosimetria, CNEN, Av. Salvador Allende s/n, CEP 22780-160 Rio de Janeiro (Brazil); Rebelo, A.M.O.; Corbo, R. [Hospital Universitario Clementino Fraga Filho, HU-UFRJ, Av. Brigadeiro Trompowsky, s/n, ILHA do Fundao, CEP 21945-560, Rio de Janeiro, RJ (Brazil)

    2007-07-01

    The manipulation of a wide variety of unsealed sources in Nuclear Medicine results in a significant risk of internal exposure of the workers. {sup 131}I should be highlighted among the most frequently used radionuclides because of its large application for diagnosis and therapy of thyroid diseases. The increasing use of radionuclides for medical purposes creates a demand for feasible methodologies to perform occupational control of internal contamination. Currently in Brazil, there are {approx}300 nuclear medicine centres in operation but individual monitoring is still restricted to the control of external exposure. This work presents the development of in vivo and in vitro bioassay techniques aimed to quantify incorporation of radionuclides used in Nuclear Medicine. It is also presented the results of a preliminary survey of internal exposure of a group of workers involved in the preparation of therapeutic doses of {sup 131}I. Workers were monitored with a gamma camera available in the Nuclear Medicine Service of the University Hospital of Rio de Janeiro and at the Institute of Radiation Protection and Dosimetry Whole-Body Counter (IRDWBC). The in vivo detection systems were calibrated with a neck-thyroid phantom developed in IRD. Urine samples from radiopharmacy workers were collected after preparation and administration of therapeutic doses (10-250 mCi) of {sup 131}I and measured with a HPGe detection system available in the Bioassay Laboratory of IRD. The results show that the bioassay methods developed in this work present enough sensitivity for routine monitoring of nuclear medicine workers. All workers monitored in this survey presented positive results for {sup 131}I in urine samples and two workers presented detectable activities in thyroid when measured at the IRD-WBC. The highest committed effective dose per preparation was estimated to be 17 {mu}Sv. (authors)

  2. Myelopoiesis in whole-body-irradiated beagles

    International Nuclear Information System (INIS)

    Stevenson, A.F.G.

    1985-01-01

    The influence of dose-rate (DR) (either 5.2 or 52 cGy/min.) on the regeneration of bone marrow (BM) myelopoietic progenitor cells was studied in beagles after exposure to whole-body-irradiation (235, 375 and 1500 cGy + autologous BM-transplantation). Myelopoietic progenitor cells were assayed as colony-forming units in agar cultures (GM-CFU), in correlation with the colony-stimulation activity (CSA) in serum. At 235 cGy, the influence of DR on the recovery of GM-CFU was insignificant. However, at 375 cGy, the recovery was critically dependent on the DR. Depletion of GM-CFU numbers elevated CSA levels above pre-irradiation values. The DR determines the regenerative ability when the dose itself is critical to survival of the least number of hematopoietic stem cells (HSC) necessary for restitution. (author)

  3. Adaptive statistical iterative reconstruction technology in the application of PET/CT whole body scans

    International Nuclear Information System (INIS)

    Xin Jun; Zhao Zhoushe; Li Hong; Lu Zhe; Wu Wenkai; Guo Qiyong

    2013-01-01

    Objective: To improve image quality of low dose CT in whole body PET/CT using adaptive statistical iterative reconstruction (ASiR) technology. Methods: Twice CT scans were performed with GE water model,scan parameters were: 120 kV, 120 and 300 mA respectively. In addition, 30 subjects treated with PET/CT were selected randomly, whole body PET/CT were performed after 18 F-FDG injection of 3.70 MBq/kg, Sharp IR+time of flight + VUE Point HD technology were used for 1.5 min/bed in PET; CT of spiral scan was performed under 120 kV using automatic exposure control technology (30-210 mA, noise index 25). Model and patients whole body CT images were reconstructed with conventional and 40% ASiR methods respectively, and the CT attenuation value and noise index were measured. Results: Research of model and clinical showed that standard deviation of ASiR method in model CT was 33.0% lower than the conventional CT reconstruction method (t =27.76, P<0.01), standard deviation of CT in normal tissues (brain, lung, mediastinum, liver and vertebral body) and lesions (brain, lung, mediastinum, liver and vertebral body) reduced by 21.08% (t =23.35, P<0.01) and 24.43% (t =16.15, P<0.01) respectively, especially for normal liver tissue and liver lesions, standard deviations of CT were reduced by 51.33% (t=34.21, P<0.0) and 49.54% (t=15.21, P<0.01) respectively. Conclusion: ASiR reconstruction method was significantly reduced the noise of low dose CT image and improved the quality of CT image in whole body PET/CT, which seems more suitable for quantitative analysis and clinical applications. (authors)

  4. Possibilities of whole-body MRI for investigating musculoskeletal diseases; Moeglichkeiten der Ganzkoerper-MRT zur Diagnostik muskuloskelettaler Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Lenk, S.; Claussen, C.D.; Schlemmer, H.P. [Klinikum der Eberhardt-Karls-Universitaet Tuebingen, Abteilung fuer Diagnostische Radiologie (Germany); Fischer, S. [Universitaetsklinikum Tuebingen, Abteilung fuer Strahlentherapie (Germany); Koetter, I. [Universitaetsklinikum Tuebingen, Abteilung fuer Haematoonkologie (Germany)

    2004-09-01

    This contribution outlines possibilities and limitations of whole-body MRI for investigating musculoskeletal diseases. Benefits and drawbacks of the novel whole-body MRI technology are discussed and a possible whole-body MRI sequence protocol for musculoskeletal examinations is proposed. Muscle, joint and bone diseases are discussed in which the application of whole-body MRI may be of advantage. Particularly, polymyositis, muscledystrophy, rheumatoid arthritis, spondylitis ancylosans, multiple trauma, skeletal metastases, multiple myeloma and malignant lymphoma are mentioned. Whole-body MRI opens new advantages for the examination of multifocal musculoskeletal diseases. The clinical benefit of this method for particular diseases has to be evaluated in further studies, however. (orig.) [German] Dieser Beitrag gibt eine Uebersicht ueber die Moeglichkeiten und Limitationen der Ganzkoerper-MRT fuer die Diagnostik von Erkrankungen des muskuloskelettalen Systems. Es werden die Vor- und Nachteile der Ganzkoerper-MRT eroertert und ein Sequenzprotokoll fuer die muskuloskelettale Diagnostik vorgeschlagen. Auf Muskel-, Gelenk- und Knochenerkrankungen, bei denen der Einsatz der Ganzkoerper-MRT indiziert erscheint, dabei insbesondere Polymyositis, Muskeldystrophie, rheumatoide Arthritis, Spondylitis ankylosans, Polytrauma, Skelettmetastasen, Plasmozytom und das maligne Lymphom wird eingegangen. Die Ganzkoerper-MRT bietet neue Moeglichkeiten, insbesondere zur Ausbreitungsdiagnostik und Verlaufskontrolle multifokaler muskuloskelettaler Erkrankungen. Der klinische Nutzen dieser Methode fuer die einzelnen Erkrankungsentitaeten muss in weiteren Studien evaluiert werden. (orig.)

  5. Diagnostic imaging in polytrauma: comparison of radiation exposure from whole-body MSCT and conventional radiography with organ-specific CT

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Lorenzen, M.; Weber, C.; Adam, G.; Nagel, H.D.

    2004-01-01

    Purpose: To compare the radiation dose of whole-body multislice CT (MSCT) and conventional radiography with organ-specific CT in polytrauma. Materials and Methods: The whole-body MSCT encompassing brain, neck and midface, chest, abdomen and pelvis was performed on a Somatom Volume Zoom (Siemens). Conventional radiography consisted of chest and cervical, thoracic and lumbar spine in two views as well as pelvis. Polymat, Siemens. Three combinations of organ specific CT were chosen: CT examination of (1) head and cervical spine, (2) head, cervical spine and chest, (3) head, cervical spine and abdomen. The effective doses of whole-body MSCT and conventional radiography with organ-specific CT were calculated. Results: Effective doses were 20 mSv for whole-body MSCT, 2 mSv for conventional x-ray, and 5 mSv for combination (1), 8 mSv for combination (2) and (3) 16 mSv for combination (3) of the organ-specific CT. The ratio of radiation dose between whole-body MSCT and radiography was 10: 1. This ratio was reduced to 3: 1, 2: 1 and 1: 1 when a combination of radiography and CT was performed. Conclusions: Whole-body MSCT in polytrauma compared to conventional radiography with organ-specific CT induces a threefold increased dose in unfavorable situations and no increased dose in favorable situations. Nevertheless, routine use of whole-body MSCT should be critically evaluated and should be adapted to the clinical benefit. (orig.) [de

  6. Effects of whole-body vibration on muscle strength and power of elderly: A systematic review

    Directory of Open Access Journals (Sweden)

    Monique Opuszcka Campos

    2014-02-01

    Full Text Available The aim of this systematic review was to summarize available scientific evidence on the utilization of whole body vibration as an alternative method to promote effective modifications on muscle strength and power in the aging population.  Scientific studies were retrieved from the following databases: Medline, Scielo, Lillacs, Cochrane Library, PEDro and Science Citation Index. The PEDro scale was used to assess the quality of the included studies, while content went through a critical analysis. From the 91 studies retrieved, 75 were excluded and 16 attended the selection criteria. From the16, the majority (68.8% presented from moderate to high methodological quality. Whole-body vibration associated to both isometric and dynamic exercises seemed to constitute an alternative for therapeutic intervention to improve muscular strength and power of healthy elderly. However, due to the characteristics of the designs of the studies reviewed and the threats to their internal validity (i.e., the absence of the control condition to the vibratory stimulus it was challenging to establish the additional effects of the whole-body vibration on the target population. Divergent findings were found for the whole-body vibration effect on muscular power. It is still necessary to conduct randomized control trials to establish the real effectiveness of this kind of intervention.

  7. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto

    1997-01-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  8. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1997-10-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  9. Benefits of whole body vibration training in patients hospitalised for COPD exacerbations - a randomized clinical trial.

    Science.gov (United States)

    Greulich, Timm; Nell, Christoph; Koepke, Janine; Fechtel, Juliane; Franke, Maja; Schmeck, Bernd; Haid, Daniel; Apelt, Sandra; Filipovic, Silke; Kenn, Klaus; Janciauskiene, Sabina; Vogelmeier, Claus; Koczulla, Andreas Rembert

    2014-04-11

    Patients with stable COPD show improvements in exercise capacity and muscular function after the application of whole body vibration. We aimed to evaluate whether this modality added to conventional physiotherapy in exacerbated hospitalised COPD patients would be safe and would improve exercise capacity and quality of life. 49 hospitalised exacerbated COPD patients were randomized (1:1) to undergo physiotherapy alone or physiotherapy with the addition of whole body vibration. The primary endpoint was the between-group difference of the 6-minute walking test (day of discharge - day of admission). Secondary assessments included chair rising test, quality of life, and serum marker analysis. Whole body vibration did not cause procedure-related adverse events. Compared to physiotherapy alone, it led to significantly stronger improvements in 6-minute walking test (95.55 ± 76.29 m vs. 6.13 ± 81.65 m; p = 0.007) and St. Georges Respiratory Questionnaire (-6.43 ± 14.25 vs. 5.59 ± 19.15, p = 0.049). Whole body vibration increased the expression of the transcription factor peroxisome proliferator receptor gamma coactivator-1-α and serum levels of irisin, while it decreased serum interleukin-8. Whole body vibration during hospitalised exacerbations did not cause procedure-related adverse events and induced clinically significant benefits regarding exercise capacity and health-related quality of life that were associated with increased serum levels of irisin, a marker of muscle activity. German Clinical Trials Register DRKS00005979. Registered 17 March 2014.

  10. A solution for 40K interference from K internal to the human body, in an underground high sensitivity whole body counter at the Waste Isolation Pilot Plant, Carlsbad, NM, USA

    Directory of Open Access Journals (Sweden)

    I. Pillalamarri

    2017-10-01

    Full Text Available The objective of the present work is to find a solution for the interference arising from 1461 keV photons emitted by 40K in natural K internal to the human body in the detection of 241Am and 210Pb activities at the level of 37 mBq (1 pCi. The response of a broad energy Ge (BEGe reference crystal to 1461 keV photons was simulated using GEANT4 code. Simulations were performed for a point source without and with shielding, as well as for a Bottle Manikin Absorption (BOMAB phantom in the shielded whole-body counting chamber (WBC. The WBC facility is located underground at the Waste Isolation Pilot Plant, Carlsbad, NM, USA. The simulation results were discussed with regards to the interference in detecting the 241Am and 210 Pb at the level of 37 mBq (1 pCi. The specific conclusion is that the interference counts from 40K activity at the natural levels present in the human body in typical clinical settings were found to be greater than the 210Pb and 241Am signal counts from 37 mBq (1 pCi, when a 38.1 mm diameter, 25.4 mm thick BEGe reference crystal was used. Our solution for minimizing the interference to the desired precision at the specified levels was found by sacrificing the broad energy response of the counting system.

  11. Potential effects of whole-body vibration exercises on blood flow ...

    African Journals Online (AJOL)

    Feasible clinical strategies such as whole-body vibration exercise (WBVE) are being used without a clear understanding of its effects. The aim of the present study is to review the effects of the WBVE on blood flow kinetics and its feasibility in different populations. Material and Methods: The level of evidence (LE) of selected ...

  12. Neurogenic Effects of Low-Dose Whole-Body HZE (Fe) Ion and Gamma Irradiation.

    Science.gov (United States)

    Sweet, Tara B; Hurley, Sean D; Wu, Michael D; Olschowka, John A; Williams, Jacqueline P; O'Banion, M Kerry

    2016-12-01

    Understanding the dose-toxicity profile of radiation is critical when evaluating potential health risks associated with natural and man-made sources in our environment. The purpose of this study was to evaluate the effects of low-dose whole-body high-energy charged (HZE) iron (Fe) ions and low-energy gamma exposure on proliferation and differentiation of adult-born neurons within the dentate gyrus of the hippocampus, cells deemed to play a critical role in memory regulation. To determine the dose-response characteristics of the brain to whole-body Fe-ion vs. gamma-radiation exposure, C57BL/6J mice were irradiated with 1 GeV/n Fe ions or a static 137 Cs source (0.662 MeV) at doses ranging from 0 to 300 cGy. The neurogenesis was analyzed at 48 h and one month postirradiation. These experiments revealed that whole-body exposure to either Fe ions or gamma radiation leads to: 1. An acute decrease in cell division within the dentate gyrus of the hippocampus, detected at doses as low as 30 and 100 cGy for Fe ions and gamma radiation, respectively; and 2. A reduction in newly differentiated neurons (DCX immunoreactivity) at one month postirradiation, with significant decreases detected at doses as low as 100 cGy for both Fe ions and gamma rays. The data presented here contribute to our understanding of brain responses to whole-body Fe ions and gamma rays and may help inform health-risk evaluations related to systemic exposure during a medical or radiologic/nuclear event or as a result of prolonged space travel.

  13. The use of comparative 137Cs body burden estimates from environmental data/models and whole body counting to evaluate diet models for the ingestion pathway

    International Nuclear Information System (INIS)

    Robison, W.L.; Sun, C.

    1997-01-01

    Rongelap and Utirik Atolls were contaminated on 1 March 1954, by a U.S. nuclear test at Bikini Atoll code named BRAVO. The people at both atolls were removed from their atolls in the first few days after the detonation and were returned to their atolls at different times. Detailed studies have been carried out over the years by Lawrence Livermore National Laboratory (LLNL) to determine the radiological conditions at the atolls and estimate the doses to the populations. The contribution of each exposure pathway and radionuclide have been evaluated. All dose assessments show that the major potential contribution to the estimated dose is 137 Cs uptake via the terrestrial food chain. Brookhaven National Laboratory (BNL) has carried out an extensive whole body counting program at both atolls over several years to directly measure the 137 Cs body burden. Here we compare the estimates of the body burdens from the LLNL environmental method with body burdens measured by the BNL whole body counting method. The combination of the results from both methods is used to evaluate proposed diet models to establish more realistic dose assessments. Very good agreement is achieved between the two methods with a diet model that includes both local and imported foods. Other diet models greatly overestimate the body burdens (i.e., dose) observed by whole body counting. The upper 95% confidence limit of interindividual variability around the population mean value based on the environmental method is similar to that calculated from direct measurement by whole body counting. Moreover, the uncertainty in the population mean value based on the environmental method is in very good agreement with the whole body counting data. This provides additional confidence in extrapolating the estimated doses calculated by the environmental method to other islands and atolls. 46 refs., 8 figs., 5 tabs

  14. Small and inconsistent effects of whole body vibration on athletic performance : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Hortobagyi, Tibor; Lesinski, Melanie; Fernandez-del-Olmo, Miguel; Granacher, Urs

    We quantified the acute and chronic effects of whole body vibration on athletic performance or its proxy measures in competitive and/or elite athletes. Systematic literature review and meta-analysis. Whole body vibration combined with exercise had an overall 0.3 % acute effect on maximal voluntary

  15. The bird's-eye views of the whole body bone scans

    Energy Technology Data Exchange (ETDEWEB)

    Machida, K; Akaike, A; Hayashi, S; Watari, T; Yasukochi, H [Tokyo Univ. (Japan). Faculty of Medicine

    1975-07-01

    Using a newly developed whole body gamma scanner (Toshiba-RDA-601), the authors recorded whole body bone scans in 5 patients (two normal, osteomalacia, bone metastases of prostate cancer and bone metastases of breast cancer), and compared the regular scintiscans with those of bird's-eye view images which were made with the data processor of the scanner. The scans were started about 2 hours after intravenous injection of 3 to 8 mCi of sup(99m)Tc-monofluorophosphate stannous fluoride. The recorded bird's-eye view scans displayed the skeletal system vividly as they were, and the distribution of radioactivity semiquantitatively. It was concluded that the bird'eye view scan is superior to the regular scan, in view of the point that it expresses the distribution of radioactivity semiquantitatively and enables one to know the amount of abnormally accumulated radioactivities by measuring the height of the peak of the diseased area, although this is very difficult in the regular scan. More clinical studies are needed in order to determine which is better for detecting abnormal part clinically.

  16. Whole-body distribution and dosimetry of O-(2-[18F]fluoroethyl)-L-tyrosine.

    Science.gov (United States)

    Pauleit, Dirk; Floeth, Frank; Herzog, Hans; Hamacher, Kurt; Tellmann, Lutz; Müller, Hans-W; Coenen, Heinz H; Langen, Karl-J

    2003-04-01

    The whole-body distribution of O-(2-[(18)F]fluoroethyl)- l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV

  17. Estimation of the protein synthesis rates of the whole body of growing broilers

    International Nuclear Information System (INIS)

    Koehler, R.; Pahle, T.; Gruhn, K.; Zander, R.; Jeroch, H.; Gebhardt, G.

    1988-01-01

    The purpose of the investigations was to prove a method, developed for monogastric mammalians, based on a 3-compartment model and assuming a proportional growth of the pools of total N, whether it is applicable to growing poultry. The tracer, 15 N-L-lysine, was given quasi-continuously for four days. In this time and in the following period of five days without tracer intake, the 15 N excretion in the urine was measured. The average of the live weight of the broiler cockerels was 1724 g. The animals were colostomized for sampling the urine separately. Using the fluxes of lysine, the calculation of the whole-body protein synthesis rate was 64.1 g/d. The protein degradation rate was 54.4 g/d. The adequate values of the fractional rates of protein synthesis and degradation for the whole body (without feathers) were 23.3% and 19.8%, resp. Thus it is clearly shown, that the method applied gives real data of the parameters of the N metabolism for growing broilers, being in the range of values for muscle proteins and proteins of the whole body of growing poultry, published by other authors. (author)

  18. Estimating the whole-body exposure annual dose of radiation workers of petroleum nuclear well logging

    International Nuclear Information System (INIS)

    Tian Yizong; Gao Jianzheng; Liu Wenhong

    2006-01-01

    Objective: By imitating experiment of radioactive sources being installed, to estimate the annual whole-body exposure dose of radiation workers of petroleum nuclear determining wells; Methods: To compre the values of the theory, imitating experiment and γ individual dose monitor calculations. Results: The three values measured above tally with one anather. Conclusion: The annual whole-body exposure doses of radiation workers of petroleum nuclear determining wells are no more than 5 mSv. (authors)

  19. Sensorimotor Reorganizations of Arm Kinematics and Postural Strategy for Functional Whole-Body Reaching Movements in Microgravity

    Directory of Open Access Journals (Sweden)

    Thomas Macaluso

    2017-10-01

    Full Text Available Understanding the impact of weightlessness on human behavior during the forthcoming long-term space missions is of critical importance, especially when considering the efficiency of goal-directed movements in these unusual environments. Several studies provided a large set of evidence that gravity is taken into account during the planning stage of arm reaching movements to optimally anticipate its consequence upon the moving limbs. However, less is known about sensorimotor changes required to face weightless environments when individuals have to perform fast and accurate goal-directed actions with whole-body displacement. We thus aimed at characterizing kinematic features of whole-body reaching movements in microgravity, involving high spatiotemporal constraints of execution, to question whether and how humans are able to maintain the performance of a functional behavior in the standards of normogravity execution. Seven participants were asked to reach as fast and as accurately as possible visual targets while standing during microgravity episodes in parabolic flight. Small and large targets were presented either close or far from the participants (requiring, in the latter case, additional whole-body displacement. Results reported that participants successfully performed the reaching task with general temporal features of movement (e.g., movement speed close to land observations. However, our analyses also demonstrated substantial kinematic changes related to the temporal structure of focal movement and the postural strategy to successfully perform -constrained- whole-body reaching movements in microgravity. These immediate reorganizations are likely achieved by rapidly taking into account the absence of gravity in motor preparation and execution (presumably from cues about body limbs unweighting. Specifically, when compared to normogravity, the arm deceleration phase substantially increased. Furthermore, greater whole-body forward displacements

  20. Elemental transfer from Chinese soil via diet to whole human body

    International Nuclear Information System (INIS)

    Zhu Hongda; Fan Tiqiang; Wu Quan; Liu Qingfen; Zhang Wei

    2007-01-01

    Objective: To calculate elemental transfer coefficients from soil via diet to whole human body and DFs of alkaline earth and alkaline metal elements in these transfers. Methods: Based on the results in this research series, including updated values of elemental dietary intakes and whole body burdens for Chinese adult man as well quoted national elemental background values in Chinese soil, their transfer coefficients and DFs of alkaline earth and alkaline metal elements in these transfers were calculated by using UNSCEAR model and Observed Ratio Method. Results: Both the transfer coefficients of 50 elements and the DF values of alkaline earth elements with Pb and alkaline metal elements in these transfers have been obtained. Conclusion: The obtained P 23 or P 234 were all much less than P 34 for these elements. For the observed elements, the highest P 23 , P 34 and P 234 were for Hg, Ca and Se respectively, while the lowest for Ce, In and Y. The P 23 and P 234 of rare earth elements were all less than those of alkaline metal or alkaline earth elements. All of these DFs for alkaline earth elements were all smaller than 1, with increasing or decreasing atomic order, the DF values of alkaline earth elements for these transfers were successfully decreasing. The DFs of Pb seem to be between Sr and Ba. For alkaline metal element, DF of Rb or Cs from soil to diet was smaller than 1, but that from diet to whole human body more than 1. (authors)

  1. Experimental investigation of biodynamic human body models subjected to whole-body vibration during a vehicle ride.

    Science.gov (United States)

    Taskin, Yener; Hacioglu, Yuksel; Ortes, Faruk; Karabulut, Derya; Arslan, Yunus Ziya

    2018-02-06

    In this study, responses of biodynamic human body models to whole-body vibration during a vehicle ride were investigated. Accelerations were acquired from three different body parts, such as the head, upper torso and lower torso, of 10 seated passengers during a car ride while two different road conditions were considered. The same multipurpose vehicle was used during all experiments. Additionally, by two widely used biodynamic models in the literature, a set of simulations were run to obtain theoretical accelerations of the models and were compared with those obtained experimentally. To sustain a quantified comparison between experimental and theoretical approaches, the root mean square acceleration and acceleration spectral density were calculated. Time and frequency responses of the models demonstrated that neither of the models showed the best prediction performance of the human body behaviour in all cases, indicating that further models are required for better prediction of the human body responses.

  2. Modulation of the gut microbiota with antibiotic treatment suppresses whole body urea production in neonatal pigs

    DEFF Research Database (Denmark)

    Puiman, Patrycja; Stoll, Barbara; Mølbak, Lars

    2013-01-01

    We examined whether changes in the gut microbiota induced by clinically relevant interventions would impact the bioavailability of dietary amino acids in neonates. We tested the hypothesis that modulation of the gut microbiota in neonatal pigs receiving no treatment (control), intravenously...... administered antibiotics, or probiotics affects whole body nitrogen and amino acid turnover. We quantified whole body urea kinetics, threonine fluxes, and threonine disposal into protein, oxidation, and tissue protein synthesis with stable isotope techniques. Compared with controls, antibiotics reduced...... the number and diversity of bacterial species in the distal small intestine (SI) and colon. Antibiotics decreased plasma urea concentrations via decreased urea synthesis. Antibiotics elevated threonine plasma concentrations and turnover, as well as whole body protein synthesis and proteolysis. Antibiotics...

  3. The Health Effects and Keep Down of Whole Body Vibration

    Directory of Open Access Journals (Sweden)

    Funda Sevencan

    2014-04-01

    Full Text Available Vibration was defined that oscillation of the body according to the reference point. The tools that are used in industry and are the source of vibration cause diseases. For this reason, the vibration has been one of the factors that affect the health and of the most widely researched in the field of ergonomics. The perceived intensity and health effects of vibration depend on the vibration frequency, intensity, direction, acceleration, duration of exposure, vibration affects the region, age, gender, posture, distance from the source person, activity, time of day and the person\\s overall health condition. The one of the most common health effects of whole body vibration is impact on musculoskeletal system. In many studies, indicated that whole-body vibration effect waist, back, shoulder and neck especially. There were varied studies that hormone levels were not changed as well there were varied studies that hormone levels were increased or decreased. There were varied studies about the digestive and circulatory system. In these studies, digestive system complaints, peptic ulcer, gastritis, varicose veins and hemorrhoids were determined frequently. For protection the health effect of vibration, Directives of the European Commission, Turkish Standards, Assessment and Management of Environmental Noise and Vibration Regulations were published. For the control of vibration are need technical and medical measures and education [TAF Prev Med Bull 2014; 13(2.000: 177-186

  4. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans

    Directory of Open Access Journals (Sweden)

    Alizé Lacoste Jeanson

    2017-05-01

    Full Text Available Background Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. Methods We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT and lean tissue (LT in such material. An intra-class correlation coefficient (ICC was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS linear regressions and support vector machine regression (SVMR. Results and Discussion The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5 and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77 than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08 for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  5. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans.

    Science.gov (United States)

    Lacoste Jeanson, Alizé; Dupej, Ján; Villa, Chiara; Brůžek, Jaroslav

    2017-01-01

    Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT) and lean tissue (LT) in such material. An intra-class correlation coefficient (ICC) was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS) linear regressions and support vector machine regression (SVMR). The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5) and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77) than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08) for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  6. Suitability of Kinect for measuring whole body movement patterns during exergaming

    NARCIS (Netherlands)

    van Diest, Mike; Stegenga, Jan; Wortche, Heinrich J.; Postema, Klaas; Verkerke, Gijsbertus J.; Lamoth, Claudine J. C.

    2014-01-01

    Exergames provide a challenging opportunity for home-based training and evaluation of postural control in the elderly population, but affordable sensor technology and algorithms for assessment of whole body movement patterns in the home environment are yet to be developed. The aim of the present

  7. Assessment of nutritional status in adult patients with cystic fibrosis: whole-body bioimpedance vs body mass index, skinfolds, and leg-to-leg bioimpedance

    NARCIS (Netherlands)

    Hollander, F.M.; Roos, de N.M.; Vries, de J.H.M.; Berkhout, van F.T.

    2005-01-01

    Objective: To investigate whether body mass index (BMI) or body fat percentage estimated from BMI, skinfolds, or leg-to-leg bioimpedance are good indicators of nutritional status in adult patients with cystic fibrosis. Body fat percentage measured by whole-body bioimpedance was used as the reference

  8. Calibration Human Voxel Phantoms for In Vivo Measurement of ''241 Am in Bone at the Whole Body Counter Facility of CIEMAT

    International Nuclear Information System (INIS)

    Moraleda, M.; Lopez, M. A.; Gomez Ros, J. M.; Navarro, T.; Navarro, J. F.

    2002-01-01

    The Whole Body Counting facility of CIEMAT is capable of carrying out In-Vivo measurements of radionuclides emitting X-rays and low energy gamma radiation internally deposited in the body. The system to use for this purpose consists of flour Low energy Germanium (LeGe) Camberra detectors working in the energy range from 10 to 1000 keV. Physical phantoms with a known contamination in the organ of interest are normally used for the calibration of the LEGe detection system. In this document we present a calibration method using the Monte Carlo technique (MCNP4C) over a voxel phantom obtained from a computerized tomography of a real human head. The phantom consists of 104017 (43x59x41) cubic voxels, 4 mn on each side, os specific tissues, but for this simulation only two types are taken into account: adipose tissue and hard bone. The skull is supposed to be contaminated with ''241 Am and the trajectories of the photons are simulated till they reach the germanium detectors. The detectors were also simulated in detail to obtain a good agreement with the reality. In order to verify the accuracy of this procedure to reproduce the experiments, the MCNP results are compared with laboratory measurements of a head phantom simulating an internal contamination of 1000 Bq of ''241 Am deposited in bone. Different relative positions source-detector were tried to look for the best counting geometry for measurement of a contaminated skull. Efficiency values are obtained and compared, resulting in the validation of the mathematical method for the assessment of internal contamination of American deposited in skeleton. (Author) 16 refs

  9. Acute effect of whole body vibration on postural control in congenitally blind subjects: a preliminary evidence.

    Science.gov (United States)

    di Cagno, Alessandra; Giombini, Arrigo; Iuliano, Enzo; Moffa, Stefano; Caliandro, Tiziana; Parisi, Attilio; Borrione, Paolo; Calcagno, Giuseppe; Fiorilli, Giovanni

    2017-07-11

    The purpose of this study was to investigate the acute effects of whole body vibration at optimal frequency, on postural control in blind subjects. Twenty-four participants, 12 congenital blind males (Experimental Group), and 12 non-disabled males with no visual impairment (Control Groups) were recruited. The area of the ellipse and the total distance of the center of pressure displacements, as postural control parameters, were evaluated at baseline (T0), immediately after the vibration (T1), after 10 min (T10) and after 20 min (T20). Whole body vibration protocol consisted into 5 sets of 1 min for each vibration, with 1 min rest between each set on a vibrating platform. The total distance of center of pressure showed a significant difference (p < 0.05) amongst groups, while the area remained constant. No significant differences were detected among times of assessments, or in the interaction group × time. No impairments in static balance were found after an acute bout of whole body vibration at optimal frequency in blind subjects and, consequently, whole body vibration may be considered as a safe application in individuals who are blind.

  10. Whole-body retention of 60Co incorporated into a seaweed in rats

    International Nuclear Information System (INIS)

    Inaba, Jiro; Nishimura, Yoshikazu; Ichikawa, Ryushi

    1979-01-01

    The objective of this study is to compare whole-body retention in the rat of radiocobalt incorporated into a marine green alga with that of 60 Co in inorganic form. Ulva pertusa was incubated in aerated seawater containing 60 Co under fluorescent lamp for 7 days. The radioactive seaweed was homogenated and was given to rats via a stomach tube. The control group of rats was given 60 CoCl 2 with homogenate of non-radioactive seaweed. Whole-body retention of the radionuclide was determined by in vivo counting of the living animal. The result revealed that rats absorbed and retained much more 60 Co incorporated into the seaweed than 60 CoCl 2 . This fact should be taken into account in the estimation of internal dose due to radiocobalt released into marine environment. (author)

  11. Effect of beta-hydroxy-beta-methylbutyrate (HMB) on protein metabolism in whole body and in selected tissues.

    Science.gov (United States)

    Holecek, M; Muthny, T; Kovarik, M; Sispera, L

    2009-01-01

    Beta-hydroxy-beta-methylbutyrate (HMB) is a leucine metabolite with protein anabolic effect. The aim of the study was to examine the role of exogenous HMB on leucine and protein metabolism in whole body and selected tissues. Rats were administered by HMB (0.1 g/kg b.w.) or by saline. The parameters of whole-body protein metabolism were evaluated 24 h later using L-[1-14C]leucine and L-[3,4,5-3H]phenylalanine. Changes in proteasome dependent proteolysis and protein synthesis were determined according the "chymotrypsin-like" enzyme activity and labeled leucine and phenylalanine incorporation into the protein. A decrease in leucine clearance and whole-body protein turnover (i.e., a decrease in whole-body proteolysis and protein synthesis) was observed in HMB treated rats. Proteasome-dependent proteolysis decreased significantly in skeletal muscle, changes in heart, liver, jejunum, colon, kidney, and spleen were insignificant. Decrease in protein synthesis was observed in the heart, colon, kidney, and spleen, while an increase was observed in the liver. There were no significant changes in leucine oxidation. We conclude that protein anabolic effect of HMB in skeletal muscle is related to inhibition of proteolysis in proteasome. Alterations in protein synthesis in visceral tissues may affect several important functions and the metabolic status of the whole body.

  12. Method of quantification of bone scintigraphy using technetium labelled stannous pyrophosphate. Results concerning 882 whole-body scintigraphy

    International Nuclear Information System (INIS)

    Chedeville, Rene.

    1976-01-01

    Considerable progress was made in isotope bone imaging with strontium 85 after the principle of quantification was introduced by Rosenthall in 1965. In 1971, Subramanian and McAffee reported that excellent visualization could be obtained with polyphosphates labelled with sup(99m)Tc. In the present study, imaging was performed 4 hours after injection of sup(99m)Tc pyrophosphate. An Elscint dual head wole body scanner and a VDP 2 off-line calculator were used. Counts were collected over selected regions of interest, each measuring 4.5 x 3.5 cm, and over the whole body. After checking reproducibility by double counting (SD of the mean = 15%), two methods of quantification were studied, the counts being expressed as: the ratio of the number of counts in the bone segment to the number of counts in the knee, the ratio of the number of counts in the bone segment/the number of counts in the whole body. In these operations, the whole body count was multiplied by 2.10 -3 in order to have a ratio whole body count.2.10 -3 /knee = 1. The ratios calculated from the different bone diseases under study were then compared [fr

  13. Thirty years after the radiation accident in Goiânia: the IRD and the learning in the face of tragedy; Trinta anos do acidente de Goiânia: a atuação do IRD e o aprendizado diante da tragédia

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, L.C.; Razuck, F.B., E-mail: fernandor@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Divisão de Ensino

    2017-07-01

    The objective of the article is to present some contributions to the learning in the radioprotection area from Goiania accident. A thematic workshop was held, together with the students of the Specialization Course in Radiological Protection and Security of Radioactive Sources, offered by the Institute of Radioprotection and Dosimetry (IRD) and the International Atomic Energy Agency (IAEA), focusing on the IRD action during the accident. Some teachers of the course gave a testimony on what was the greatest legacy of the accident for the radioprotection area. From the analysis of the speeches, a workshop was held to discuss the relevance of the accident. It was sought to evidence the radiological accident as a learning tool in the field of nuclear science, opening space for discussions of a wider knowledge about ionizing radiation. Thus, it is not possible to deny the technological advance and the learning originated from this tragedy in Brazilian soil, understanding that the investigations related to historical aspects of science end up leading to new implications in the teaching of sciences.

  14. Calibration Human Voxel Phantoms for In Vivo Measurement of ''2 sup 4 sup 1 Am in Bone at the Whole Body Counter Facility of CIEMAT

    CERN Document Server

    Moraleda, M; Navarro, J F; Navarro, T

    2002-01-01

    The Whole Body Counting facility of CIEMAT is capable of carrying out In-Vivo measurements of radionuclides emitting X-rays and low energy gamma radiation internally deposited in the body. The system to use for this purpose consists of flour Low energy Germanium (LeGe) Camberra detectors working in the energy range from 10 to 1000 keV. Physical phantoms with a known contamination in the organ of interest are normally used for the calibration of the LEGe detection system. In this document we present a calibration method using the Monte Carlo technique (MCNP4C) over a voxel phantom obtained from a computerized tomography of a real human head. The phantom consists of 104017 (43x59x41) cubic voxels, 4 mn on each side, os specific tissues, but for this simulation only two types are taken into account: adipose tissue and hard bone. The skull is supposed to be contaminated with ''241 Am and the trajectories of the photons are simulated till they reach the germanium detectors. The detectors were also simulated in det...

  15. Subjective evaluation of the effectiveness of whole-body cryotherapy in patients with osteoarthritis

    Directory of Open Access Journals (Sweden)

    Tomasz Chruściak

    2016-12-01

    Full Text Available Objectives: One of the treatments for osteoarthritis (OA is whole-body cryotherapy (WBC. The aim of this study is to assess the effect of whole-body cryotherapy on the clinical status of patients with osteoarthritis (OA, according to their subjective feelings before and after the application of a 10-day cold treatment cycle. The aim is also to assess the reduction of intensity and frequency of pain, the reduction of the painkiller medication used, and to assess the possible impact on physical activity. Material and methods : The study involved 50 people, including 30 women (60% and 20 men (40%. Thirty-one patients had spondyloarthritis (62% of respondents, 10 had knee osteoarthritis (20%, and 9 hip osteoarthritis (18%. The overall average age was 50.1 ±10.9 years; the youngest patient was 29 years old and the oldest 73 years old. The average age of the women was 6 years higher. The study used a questionnaire completed by patients, and consisted of three basic parts. The modified Laitinen pain questionnaire contained questions concerning the intensity and frequency of pain, frequency of painkiller use and the degree of limited mobility. The visual analogue scale (VAS was used in order to subjectively evaluate the therapy after applying the ten-day treatment cycle. Results: According to the subjective assessment of respondents, after the whole-body cryotherapy treatments, a significant improvement occurred in 39 patients (78%, an improvement in 9 patients (18%, and no improvement was only declared by 2 patients (4%. Conclusions : Whole-body cryotherapy resulted in a reduction in the frequency and degree of pain perception in patients with osteoarthritis. WBC reduced the number of analgesic medications in these patients. It improved the range of physical activity and had a positive effect on the well-being of patients.

  16. Whole body bone scintigraphy in tenofovir-related osteomalacia: a case report

    Directory of Open Access Journals (Sweden)

    Di Biagio Antonio

    2009-07-01

    Full Text Available Abstract Introduction Tenofovir disoproxil fumarate (Viread® is the only nucleotide reverse transcriptase inhibitor currently approved for the treatment of HIV. It is frequently prescribed not only for its efficacy but also for its decreased side effect profile compared with other nucleotide analogs. In addition, it is now increasingly recognized as a cause of acquired Fanconi's syndrome in individuals with HIV. Case presentation We describe a 48-year-old woman infected with HIV, with chronic renal insufficiency, who developed Fanconi's syndrome after inclusion of tenofovir disoproxil fumarate in her antiretroviral therapy. A whole body bone scintigraphy was performed, revealing an abnormal distribution of radiotracer uptake, with characteristic changes compatible with osteomalacia. All symptoms disappeared after tenofovir discontinuation and mineral supplementation. No other explanation for the sudden and complete resolution of the bone disease was found. Conclusion The case highlights the role of whole body bone scintigraphy in the diagnosis of tenofovir-related osteomalacia.

  17. Body composition in acromegaly - before and after therapy

    International Nuclear Information System (INIS)

    Brummer, R.J.M.; Bengtsson, B.A.; Isaksson, B.

    1986-01-01

    Acromegaly is a disease caused by a benign pituitary tumor producing excess amount of growth hormone. A changed body composition can be a functional parameter of the disorder. The aim of this study is to describe body composition in acromegaly before and after therapy. Total body potassium (TBK) was measured as total exchangeable potassium using 42 K by dilution technique or by counting gamma radiation from the naturally present 40 K in a high sensitivity 3π whole body counter. Total body water (TBW) was determined with an isotope dilution technique using tritiated water as a tracer. The specific activity was measured in urine or plasma. The predicted values for TBK, TBW, and body fat (BF) were calculated by equations using body weight (BW), body height, age and sex as independent variables. The normal values for BW were calculated by using body height and sex as independent variables

  18. Influence of whole-body gamma irradiation upon arachidonic acid metabolism in rat platelets

    International Nuclear Information System (INIS)

    Lognonne, J.L.; Ducousso, R.; Rocquet, G.; Kergonou, J.F.

    1985-01-01

    The effects of whole-body gamma irradiation (8.4 Gy) were studied on arachidonic acid (AA) metabolism in rat's blood platelets, from day D + 1 to day D + 10 after irradiation. AA conversion into thromboxane B 2 (TxB 2 ) increased at D + 1 and then gradually decreased to very low values from D + 7 to D + 10. This decrease in the conversion of exogenous AA into TxB 2 was due to a lower AA incorporation into platelets and not to a decrease of cyclooxygenase and thromboxane-synthetase activities. AA incorporation into membrane phospholipids of blood platelets was much more decreased than AA incorporation into whole platelets; moreover, the lipid composition of the platelet membranes was markedly modified after irradiation, which must have resulted in structural and functional changes in these membranes; from these effects of whole-body gamma irradiation on platelets, the latter's membranes appeared as a major site of in vivo radiation damage in these cells

  19. Ocular Counter Rolling in Astronauts After Short- and Long-Duration Spaceflight.

    Science.gov (United States)

    Reschke, Millard F; Wood, Scott J; Clément, Gilles

    2018-05-17

    Ocular counter-rolling (OCR) is a reflex generated by the activation of the gravity sensors in the inner ear that stabilizes gaze and posture during head tilt. We compared the OCR measures that were obtained in 6 astronauts before, during, and after a spaceflight lasting 4-6 days with the OCR measures obtained from 6 astronauts before and after a spaceflight lasting 4-9 months. OCR in the short-duration fliers was measured using the afterimage method during head tilt at 15°, 30°, and 45°. OCR in the long-duration fliers was measured using video-oculography during whole body tilt at 25°. A control group of 7 subjects was used to compare OCR measures during head tilt and whole body tilt. No OCR occurred during head tilt in microgravity, and the response returned to normal within 2 hours of return from short-duration spaceflight. However, the amplitude of OCR was reduced for several days after return from long-duration spaceflight. This decrease in amplitude was not accompanied by changes in the asymmetry of OCR between right and left head tilt. These results indicate that the adaptation  of otolith-driven reflexes to microgravity is a long-duration process.

  20. Whole-Body MRI versus PET in assessment of multiple myeloma disease activity.

    LENUS (Irish Health Repository)

    Shortt, Conor P

    2009-04-01

    The purpose of this study was to compare FDG PET; whole-body MRI; and the reference standard, bone marrow aspiration and biopsy, to determine the best imaging technique for assessment of disease activity in multiple myeloma.

  1. Effects of whole-body vibration on balance and mobility in institutionalized older adults: a randomized controlled trial.

    Science.gov (United States)

    Lam, Freddy Mh; Chan, Philip Fl; Liao, L R; Woo, Jean; Hui, Elsie; Lai, Charles Wk; Kwok, Timothy Cy; Pang, Marco Yc

    2018-04-01

    To investigate whether a comprehensive exercise program was effective in improving physical function among institutionalized older adults and whether adding whole-body vibration to the program conferred additional therapeutic benefits. A single-blinded randomized controlled trial was conducted. This study was carried out in residential care units. In total, 73 older adults (40 women, mean age: 82.3 ± 7.3 years) were enrolled into this study. Participants were randomly allocated to one of the three groups: strength and balance program combined with whole-body vibration, strength and balance program without whole-body vibration, and social and recreational activities consisting of upper limb exercises only. All participants completed three training sessions per week for eight weeks. Assessment of mobility, balance, lower limb strength, walking endurance, and self-perceived balance confidence were conducted at baseline and immediately after the eight-week intervention. Incidences of falls requiring medical attention were recorded for one year after the end of the training period. A significant time × group interaction was found for lower limb strength (five-times-sit-to-stand test; P = 0.048), with the exercise-only group showing improvement (pretest: 35.8 ± 16.1 seconds; posttest: 29.0 ± 9.8 seconds), compared with a decline in strength among controls (pretest: 27.1 ± 10.4 seconds; posttest: 28.7 ± 12.3 seconds; P = 0.030). The exercise with whole-body vibration group had a significantly better outcome in balance confidence (pretest: 39.2 ± 29.0; posttest: 48.4 ± 30.6) than the exercise-only group (pretest: 35.9 ± 24.8; posttest: 38.2 ± 26.5; P = 0.033). The exercise program was effective in improving lower limb strength among institutionalized older adults but adding whole-body vibration did not enhance its effect. Whole-body vibration may improve balance confidence without enhancing actual balance performance.

  2. Whole body plastination, intra-organ heterogeneity, and tissue based diagnosis – a survey

    Directory of Open Access Journals (Sweden)

    Gunther von Hagens

    2018-04-01

    Full Text Available  Background: The corpse is the final structural relict of life. Its detailed analysis, the autopsy formed the basis and contributed significantly to our understanding of location, function and interaction of organs in man. Today, autopsies are performed rarely. They have been replaced by radiological in vivo visualization techniques and the analysis of organ excisions and biopsies. Which attributes do whole body preservations possess in this context? Techniques of Whole Body Analysis: In vivo imaging transfers the appearance of body organs and cellular structures in virtual images. The patient’s exposure to X-rays, fundamental particles (electrons, positrons, etc., strong magnetic fields (nuclear resonance, or ultra sounds release the corresponding signals. The obtained images are interpreted in search for local abnormalities such as cancer, acute and chronic infections, inborn errors, hypertrophy or atrophy. Autopsies require the removal and visual inspection of organs shortly after the victim’s death. In addition, tissue probes of suspicious lesions are fixed and microscopically analyzed. The search for gene or protein abnormalities are added dependent upon the clinical history and gross findings. The whole body plastination is performed in separated steps which include fixation, anatomical dissection, forced polymer impregnation, positioning and curing. Organs and other tissue structures can be taken out of the body and separately demonstrated, or aligned and fixed within the body. Additional tissue examinations are possible at this stage, which is followed by hardening and fixation of the still flexible body. Fixation is done with heat, light or gas.   Results and Interpretation: Tissue conservation is a prerequisite to analyze and investigate in diagnosis and forecast of disease occurrence and behaviour. In history, autopsies have opened the door to localize the position and to understand the functions of organs. Today, they have been

  3. Whole body dosimetry for treatment individualized neuroblastoma with 131I-MIBG

    International Nuclear Information System (INIS)

    Ferrer Gracia, C.; Luquero Llopis, N.; Sanchez Munoz, F.; Plaza Aparicio, R.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-01-01

    It according to in this study, that in therapy with 1 31I-MIBG for the treatment of neuroblastoma, it can prescribe and manage dose whole body accurately, allowing individualized treatments and major activities that in the treatments based on a fixed activity according to weight management. (Author)

  4. Whole body clearance of norepinephrine. The significance of arterial sampling and of surgical stress

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Madsbad, S

    1983-01-01

    The whole body clearance of norepinephrine (NE) was measured in seven patients pre- and postoperatively. L[(3)H]NE was infused intravenously for 90 min and steady-state concentrations of L[(3)H]NE were measured at 75 and 90 min in both arterial and peripheral venous blood. Preoperatively, in the ......The whole body clearance of norepinephrine (NE) was measured in seven patients pre- and postoperatively. L[(3)H]NE was infused intravenously for 90 min and steady-state concentrations of L[(3)H]NE were measured at 75 and 90 min in both arterial and peripheral venous blood. Preoperatively...

  5. Whole Body Vibration Improves Cognition in Healthy Young Adults

    OpenAIRE

    Regterschot, G. Ruben H.; Van Heuvelen, Marieke J. G.; Zeinstra, Edzard B.; Fuermaier, Anselm B. M.; Tucha, Lara; Koerts, Janneke; Tucha, Oliver; Van Der Zee, Eddy A.

    2014-01-01

    This study investigated the acute effects of passive whole body vibration (WBV) on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5 +/- 2.2 years) underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm) and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on ...

  6. Whole-body distribution and dosimetry of O-(2-[18F]fluoroethyl)-l-tyrosine

    International Nuclear Information System (INIS)

    Pauleit, Dirk; Floeth, Frank; Herzog, Hans; Tellmann, Lutz; Langen, Karl-J.; Hamacher, Kurt; Coenen, Heinz H.; Mueller, Hans-W.

    2003-01-01

    The whole-body distribution of O-(2-[ 18 F]fluoroethyl)-l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV ≤1.6) which remained constant between early and late PET scans. No increased uptake was seen in the bone, the biliary tract or the pancreas. Twenty-two percent of the injected activity was excreted 5 h p.i. (approx. 5.3% ID/h). The highest absorbed dose was found for the urinary bladder wall. The effective dose according to ICRP 60 was 16.5 μSv/MBq for adults, which would lead to an effective dose of 6.1 mSv in a PET study using 370 MBq FET. (orig.)

  7. Accuracy of 24-h whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Scullion, J.E.; Bessent, R.; Cuthbert, G.F.

    1982-01-01

    The 24-h whole-body retention (WBR) of diphosphonate was a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r=0.998, R<0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. A phantom was used to assess the possible error introduced by redistribution of tracer. The net whole-body count of the phantom representing the 24-h distribution was 98% of that of a uniform phantom. Ten subjects were counted twice within a few minutes to study the effect of repositioning, and showed a mean difference between counts of only 0.8%. Eleven subjects with traumatic fractures were studied to assess the possible contribution of focal lesions to WBR. It was found that nine subjects had normal values for WBR, while two had minimally elevated results. Twenty patients with renal disease but no apparent skeletal disease were also studied to assess the possible contribution of soft-tissue retention to WBR. A significant correlation between serum creatinine and WBR was found (r=0.72, P<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/1. It is suggested that WBR measurement is accurate and the technique is hgihly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is the normal range then WBR can be assumed to reflect skeletal metabolism without further concern as to renal function. (orig.)

  8. Whole body MR in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Piekarek, A.; Sosnowski, P.; Nowicki, A.; Komarnicki, M.

    2009-01-01

    Background: Multiple myeloma is a cancer of plasma cells which leads to bone marrow infiltration. Aim: Whole-body MR is the most sensitive imaging method available to detect multiple myeloma lesions. Ma terial and methods: MR scans were performed in 100 patients with multiple myeloma who were receiving treatment in the Haematology Clinic in Poznan in the years 2005 - 2006. Whole-body MR scans were performed with general coil 1.0 T in STIR sequences and T1 sequences, in coronal and sagittal planes with scanning area covering the head, neck, trunk and the limbs (FOV for specific regions was 36 -48 cm). The bone lesions were classified as focal (monofocal/multifocal lesions), infiltrative, mixed and 'salt and pepper' type. Depending on the size of the lesions the patients were included in one of three groups according to Salmon-Durie Plus classification. Results: Four main types of multiple myeloma were distinguished based on MR scans: focal (48 patients; monofocal in 10 patients), infiltrative (17 patients), mixed type (19 patients) and 'salt and pepper' type (4 patients). The remaining 12 patients had no multiple myeloma lesions in the bone marrow. Additionally, in 18% of patients a soft tissue mass could be observed. According to Salmon-Durie Plus categorisation 27 subjects were classified as having stage I, 16 patients stage and 57 patients stage III disease. In 12% of patients MR data changed the disease staging. Conclusions: WB MR is a sensitive and effective diagnostic method with an important impact on staging and further treatment of multiple myeloma. (authors)

  9. Effects of whole-body irradiation on neonatally thymectomized mice. Incidence of benign and malignant tumors

    International Nuclear Information System (INIS)

    Anderson, R.E.; Howarth, J.L.; Troup, G.M.

    1978-01-01

    The individual and combined effects of neonatal thymectomy and whole-body irradiation on the prevalence of benign and malignant tumors in germ-free female mice of the Charles Rivers line were studied to determine if a portion of the tumorigenic effects of irradiation can be attributed to injury of the thymic-dependent component of the immune response. Neonatal thymectomy increased (a) the incidence of benign and malignant tumors and (b) the prevalence of multiple primary neoplasms in an individual mouse. Whole-body exposure to 700 rad at 6 weeks of age further increased the incidence of tumors, but the relative magnitude of this increase was less pronounced than in sham-operated controls. Thus, the cumulative effects of thymectomy plus irradiation are less pronounced than the sum of the individual effects. One of several possible explanations for this observation is that a portion of the carcinogenic effects of whole-body irradiation is mediated by suppression of the thymic-dependent component of the immune response

  10. Effect of meal and propranolol on whole body and splanchnic oxygen consumption in patients with cirrhosis

    DEFF Research Database (Denmark)

    Krag, Aleksander; Simonsen, Lene; Henriksen, Jens H

    2006-01-01

    Our aim was to measure whole body energy expenditure after a mixed liquid meal, with and without simultaneous propranolol infusion, in patients with cirrhosis. We also wanted to investigate the effect of propranolol on substrate fluxes and oxygen uptake in the tissues drained by the hepatic vein ...... as splanchnic oxygen uptake. The splanchnic reduction in oxygen consumption can explain almost the entire reduction in whole body oxygen consumption....

  11. Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters

    International Nuclear Information System (INIS)

    Takeda, Naoto; Kudo, Katsuhisa; Kobayashi, Katsuhei; Yoshimoto, Takaaki

    2000-01-01

    The relative gas multiplication along the cylindrical axis of three 3 He proportional counters with different length were measured by using a thermal neutron beam at the Kyoto University Reactor and an ideal response function by taking into account the difference of pulse height spectra were measured by different length counters. The three 3 He proportional counters (model type of P4-0806, P4-0806 and P4-0808 manufactured by Reuter-Stokes) prepared for relative gas multiplication measurements had identical structure having cylindrical outer shells of 304 stainless steel except for different sensitive lengths of 10 cm, 15 cm and 20 cm, respectively. All counters were filled with 400 kPa of 3 He gas and 200 kPa of Ar gas. The pulse height distributions were measured by moving the counter in the direction of it's cylindrical axis perpendicular to the thermal neutron beam. The measured pulse heights corresponding to the full energy peaks at various entrance points were normalized to that of the whole counter irradiation. The results as a function of the distance from the bottom edge of the stainless steel cylinder are shown. The total transition region of gas gain corresponded to about 23 %, 15 % and 10 % of each nominal sensitive region corresponding to shot, middle and long counters. The ideal pulse height spectrum (dots) obtained by using proportional counters of 10 cm and 20 cm in nominal sensitive length to thermal neutron beam is shown in the paper in comparison to simulated one which was calculated assuming the constant gain within the sensitive region and zero gas gain outside the sensitive regions. The simulation realized the ideal response function fairly well. (S.Y.)

  12. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  13. Inhibitory mechanism of low-dose, whole-body irradiation with gamma-rays against tumor metastasis

    International Nuclear Information System (INIS)

    Yasuhiro Ohsima; Mitsutoshi Tukimoto; Shuji Kojima

    2007-01-01

    Complete text of publication follows. A lot of beneficial effects of low-dose irradiation are well known. Of them, an inhibitory effect of the radiation on lung metastasis is reported so far. It has been reported that low-dose whole-body irradiation with gamma rays enhanced cytotoxic immune response as one of the mechanisms. In our laboratory, it has been confirmed an enhancement of natural killer activity in mice irradiated with whole-body 0.5Gy gamma-rays. Metastasis is accomplished by multistep process, involving basement membrane destruction, local invasion, intravasation, survival in the bloodstream, extravasation into distant organs, and proliferation at the target site. Besides, a lot of growth factors and proteases are involved in these steps. As to mechanism of inhibition of tumor metastasis induced by low-dose whole-body irradiation, studies from the standpoint of tumor invasion have not been reported. Here, inhibitory effect of 0.5Gy whole-body gamma-ray irradiation on tumor metastasis and its mechanism were examined in pulmonary metastasis model mice injected with B16 melanoma cells. Consequently, 0.5Gy whole-body gamma ray irradiation significantly suppressed colony formation in the lungs. Expression of matrix metalloproteinase- 2 (MMP- 2), a proteinase related to metastasis, in lung tissues was suppressed by the radiation. Alteration of tissue inhibitor of matrix metalloproteinase (TIMP) after the gamma-ray irradiation was examined. Expression of TIMP-1 and TIMP-2 mRNA in the lungs were significantly increased. In order to clarify the inhibitory effect obtained in the in vivo metastatic lung cancer model mice, we studied effects of gamma-rays on cell proliferation, alterations of mRNA and proteins related to tumor metastasis in cultured B16 melanoma cells. Proliferation of B16 melanoma cells was decreased in a dose-dependent manner. MMP-2 mRNA expression was not altered in any doses of gamma-rays. Thought expression of the protein was slightly

  14. Open-Ended Measurement of Whole-Body Movement: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Finn, Michael T. M.

    2018-02-01

    Full Text Available As the importance of embodiment emerges for psychology, there is a need to advance methodology for measuring the dynamics of movement in an open-ended fashion. Such a tool should be versatile across contexts and track spontaneous and natural movement with minimal constraints. We test the feasibility of a method for measuring whole-body movement over time that attempts to meet this need. We use a motion capture system comprised of two Microsoft Kinect version 2.0 cameras and iPiSoft Motion Capture software, and compare its estimates of magnitude rotational velocity and whole-body movement complexity (multivariate multiscale sample entropy; MMSE to that of a gold standard motion capture system across a variety of movement sequences. The candidate system satisfactorily estimated the instantaneous velocity of 13 body segments in agreement with the gold standard system across movement sequences demonstrating initial feasibility of this process. Summary calculations of velocity by sequence and MMSE calculations were also in high agreement with the gold standard, crucially suggesting that the candidate system could pick up on the complex dynamics of movement over time. The candidate system was feasible and demonstrates preliminary validity for general use in the tracking of continuous human movement for clinical and experimental psychology. We also provide R code and sample data for the importing and processing of movement data exported from iPiSoft Motion Capture Studio.

  15. Effects of whole body UV-irradiation on oxygen delivery from the erythrocyte

    International Nuclear Information System (INIS)

    Humpeler, E.; Mairbaeurl, H.; Hoenigsmann, H.

    1982-01-01

    In 16 healthy caucasian volunteers (mean age: 22.2 years) the influence of whole body UV-irradiation on the oxygen transport properties of erythrocytes was investigated. Four hours after irradiation with UV (using the minimal erythema dose, MED) no variation of haemoglobin concentration, hematocrit, mean corpuscular haemoglobin concentration, pH or standard bicarbonate could be found, whereas inorganic plasma phosphate (Psub(i)), calcium, the intraerythrocytic 2,3-diphosphoglycerate (2,3-DPG), the activity of erythrocytic phosphofructokinase (PFK) and pyruvatekinase (PK) increased significantly. The half saturation tension of oxygen (P 50 -value) tended to increase. The increase of Psub(i) causes - via a stimulation of the glycolytic pathway - an increase in 2,3-DPG concentration and thus results in a shift of the oxygen dissociation curve. It is therefore possible to enhance tissue oxygenation by whole body UV-irradiation. (orig.)

  16. Start up of the whole body detection system

    International Nuclear Information System (INIS)

    Cortes P, A.; Angeles C, A.; Cuapio O, A.; Tejera R, A.

    1991-12-01

    The management of Radiological Safety of the Nuclear Center of Mexico has a whole body detection system Trade mark Canberra, manufactured by Bio-nuclear Measurements Inc. Ipswich Massachusetts. These systems are used to detect contamination of I-131 in thyroid and other nuclides (Cs-137, Cs-134, Co-60, etc.) in thorax. In this work the procedure that was continued for the setting in march of the thyroid detector is presented. A description of this system and an analysis of the uncertainties involved in the measures of activity of I-131 in thyroid of people occupationally exposed is made. (Author)

  17. Whole body BMC in pediatric Crohn disease: independent effects of altered growth, maturation, and body composition.

    Science.gov (United States)

    Burnham, Jon M; Shults, Justine; Semeao, Edisio; Foster, Bethany; Zemel, Babette S; Stallings, Virginia A; Leonard, Mary B

    2004-12-01

    Whole body BMC was assessed in 104 children and young adults with CD and 233 healthy controls. CD was associated with significant deficits in BMC and lean mass, relative to height. Adjustment for lean mass eliminated the bone deficit in CD. Steroid exposure was associated with short stature but not bone deficits relative to height. Children with Crohn disease (CD) have multiple risk factors for impaired bone accrual. The confounding effects of poor growth and delayed maturation limit the interpretation of prior studies of bone health in CD. The objective of this study was to assess BMC relative to growth, body composition, and maturation in CD compared with controls. Whole body BMC and lean mass were assessed by DXA in 104 CD subjects and 233 healthy controls, 4-26 years of age. Multivariable linear regression models were developed to sequentially adjust for differences in skeletal size, pubertal maturation, and muscle mass. BMC-for-height z scores were derived to determine CD-specific covariates associated with bone deficits. Subjects with CD had significantly lower height z score, body mass index z score, and lean mass relative to height compared with controls (all p BMC in CD relative to controls was significantly reduced in males (0.86; 95% CI, 0.83, 0.94) and females (0.91; 95% CI, 0.85, 0.98) with CD. Adjustment for pubertal maturation did not alter the estimate; however, addition of lean mass to the model eliminated the bone deficit. Steroid exposure was associated with short stature but not bone deficits. This study shows the importance of considering differences in body size and composition when interpreting DXA data in children with chronic inflammatory conditions and shows an association between deficits in muscle mass and bone in pediatric CD.

  18. Real-time stylistic prediction for whole-body human motions.

    Science.gov (United States)

    Matsubara, Takamitsu; Hyon, Sang-Ho; Morimoto, Jun

    2012-01-01

    The ability to predict human motion is crucial in several contexts such as human tracking by computer vision and the synthesis of human-like computer graphics. Previous work has focused on off-line processes with well-segmented data; however, many applications such as robotics require real-time control with efficient computation. In this paper, we propose a novel approach called real-time stylistic prediction for whole-body human motions to satisfy these requirements. This approach uses a novel generative model to represent a whole-body human motion including rhythmic motion (e.g., walking) and discrete motion (e.g., jumping). The generative model is composed of a low-dimensional state (phase) dynamics and a two-factor observation model, allowing it to capture the diversity of motion styles in humans. A real-time adaptation algorithm was derived to estimate both state variables and style parameter of the model from non-stationary unlabeled sequential observations. Moreover, with a simple modification, the algorithm allows real-time adaptation even from incomplete (partial) observations. Based on the estimated state and style, a future motion sequence can be accurately predicted. In our implementation, it takes less than 15 ms for both adaptation and prediction at each observation. Our real-time stylistic prediction was evaluated for human walking, running, and jumping behaviors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Counter-Rotatable Fan Gas Turbine Engine with Axial Flow Positive Displacement Worm Gas Generator

    Science.gov (United States)

    Giffin, Rollin George (Inventor); Murrow, Kurt David (Inventor); Fakunle, Oladapo (Inventor)

    2014-01-01

    A counter-rotatable fan turbine engine includes a counter-rotatable fan section, a worm gas generator, and a low pressure turbine to power the counter-rotatable fan section. The low pressure turbine maybe counter-rotatable or have a single direction of rotation in which case it powers the counter-rotatable fan section through a gearbox. The gas generator has inner and outer bodies having offset inner and outer axes extending through first, second, and third sections of a core assembly. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes and extending radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. A combustor section extends through at least a portion of the second section.

  20. A preliminary study of iron absorption by whole body counting and correlation with DFO excretion

    International Nuclear Information System (INIS)

    Gupta, M.M.; Bhattacharyya, L.; Gupta, N.K.; Bhola, G.C.; Nagaratnam, A.; Manchanda, R.; Bhargva, M.; Kumar, S.

    1975-01-01

    A preliminary study of iron absorption by oral administration of 59 Fe and whole body counting was carried on a group of 16 women. The cases included 8 patients suffering from iron deficiency anaemia and various infections as well as 8 healthy controls. High iron absorption is associated with iron deficiency, these changes being more marked in iron deficient controls than in those with infection or malignancy. In iron deficient controls results of whole body counting correlate very well with other haematological investigations. (orig.) [de

  1. Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics

    DEFF Research Database (Denmark)

    Maroy, Renaud; Boisgard, Raphaël; Comtat, Claude

    2008-01-01

    Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new...... method for the segmentation of rodent whole-body PET images that takes these two difficulties into account by estimating the pharmacokinetics far from organ borders. The segmentation method proved efficient on whole-body numerical rat phantom simulations, including 3-14 organs, together...

  2. Various performance-enhancing effects from the same intensity of whole-body vibration training

    Directory of Open Access Journals (Sweden)

    Paohung Chung

    2017-09-01

    Conclusion: All frequency and amplitude settings in the 8-week whole-body vibration training increased muscle strength, but different settings resulted in various neuromuscular adaptations despite the same intensity.

  3. Evaluation the sources of uncertainty associated to the measurement results of in vivo monitoring of iodine 131 in the thyroid

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo Modesto Gadelha

    2011-01-01

    In vivo monitoring techniques consist of identification and quantification of radionuclides present in the whole body and specific organs and tissues. In Vivo monitoring requires the use of detedors which are sensitive to the radiation emitted by radionuclides present in the monitored individual. The results obtained in measurements may present small uncertainties which are within pre-set limits in monitoring programs for occupationally exposed individuais. However, any device used to determine physical quantities present uncertainties in the measured values. The total uncertainty of a measurement result is estimated from the propagation of the uncertainties associated to each parameter of the calculation. This study aims to evaluate the sources of uncertainty associated to the measurement results of in vivo monitoring of iodine 131 in the thyroid, in comparison to the suggested in the General Guide for Estimating Effective Doses from Monitoring Data (Project IDEAS/European Community). The reference values used were the ones for high-energy photons (>100 keV). The measurement uncertainties were divided into two categories: type A and type B. The component of type A represents the statistical fluctuation in the counting of the standard source. Regarding type B, the following variations were presented: detector positioning over the phantom; variation of background radiation; thickness of the overlay tissue over the monitored organ, distribution of the activity in the organ. Besides the parameters suggested by the IDEAS Guide, it has also been evaluated the fluctuation of the counting due to the phantom repositioning, which represents the reproducibility of the measurement geometry. Measurements were performed at the Whole Body Counter Unit of IRD using a scintillation detector Nal (Tl) 3 x3 and a neck-thyroid phantom developed at LABMIVIRD. Scattering factors were calculated and compared in different counting geometries. The results of this study show that the

  4. Numerical analysis of whole-body cryotherapy chamber design improvement

    Science.gov (United States)

    Yerezhep, D.; Tukmakova, A. S.; Fomin, V. E.; Masalimov, A.; Asach, A. V.; Novotelnova, A. V.; Baranov, A. Yu

    2018-05-01

    Whole body cryotherapy is a state-of-the-art method that uses cold for treatment and prevention of diseases. The process implies the impact of cryogenic gas on a human body that implements in a special cryochamber. The temperature field in the chamber is of great importance since local integument over-cooling may occur. Numerical simulation of WBC has been carried out. Chamber design modification has been proposed in order to increase the uniformity of the internal temperature field. The results have been compared with the ones obtained for a standard chamber design. The value of temperature gradient formed in the chamber containing curved wall with certain height has been decreased almost twice in comparison with the results obtained for the standard design. The modification proposed may increase both safety and comfort of cryotherapy.

  5. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  6. Intermittent fasting does not affect whole-body glucose, lipid, or protein metabolism

    NARCIS (Netherlands)

    Soeters, Maarten R.; Lammers, Nicolette M.; Dubbelhuis, Peter F.; Ackermans, Mariëtte T.; Jonkers-Schuitema, Cora F.; Fliers, Eric; Sauerwein, Hans P.; Aerts, Johannes M.; Serlie, Mireille J.

    2009-01-01

    Background: Intermittent fasting (IF) was shown to increase whole-body insulin sensitivity, but it is uncertain whether IF selectively influences intermediary metabolism. Such selectivity might be advantageous when adapting to periods of food abundance and food shortage. Objective: The objective was

  7. Changes in serum 25-hydroxyvitamin D and cholecalciferol after one whole-body exposure in a commercial tanning bed

    DEFF Research Database (Denmark)

    Langdahl, Jacob H; Schierbeck, Louise Lind; Bang, Ulrich Christian

    2012-01-01

    We wanted to evaluate the cutaneous synthesis of 25OHD and cholecalciferol after one whole-body exposure to ultraviolet radiation type B (UVB) in a randomized setup. Healthy volunteers were randomized to one whole-body exposure in a commercial tanning bed with UVB emission (UVB/UVA ratio 1...

  8. Efficiency Calibration of Phantom Family for Use in Direct Bioassay of Radionuclide in the Body

    International Nuclear Information System (INIS)

    Kim, Ji Seok; Ha, Wi Ho; Kim, Hyun Ki; Park, Gyung Deok; Lee, Jai Ki

    2008-01-01

    A major source of uncertainties of in vivo bioassay using a whole body counter calibrated against a body phantom containing known radioactivities is variation of counting geometry caused by the differences in body size of the subject from that of the phantom. Phantoms such as the BOMAB phantom are based on the body size of the reference man and usually single phantom is used in usual calibration of the counter. This is because it is difficult to apply a set of phantoms having different sizes. In order to reduce the potential errors due to variation of counting geometry, use of a set of phantoms having different body-shapes have been attempted. The efficiency files are stored in the computer analyzing the measurement data and a suitable one is retrieved for the specific subject. Experimental or computational approach can be employed in generation of the efficiency files. Carlan et al. demonstrated that Monte Carlo simulations can provide acceptable efficiencies by use of the IGOR phantom family. The body size of the individual subject undergoing in vivo bioassay should be determined by an appropriate method

  9. Influence of Tire Characteristics of Interurban Taxis on Exposure Level to Drivers Whole-Body Vibrations

    Directory of Open Access Journals (Sweden)

    Milad Derakhshanjazari

    2016-03-01

    Full Text Available Introduction: Taxi drivers’ exposure to repeat whole-body vibrations can cause back pain and digestive disorders. Since this type of vibration depends on the car components, this study was carried out to determine the influence of tire characteristics on the amount of whole-body vibrations transmitted to the Peugeot 405 taxi drivers. Methods: In this experimental study, vibration characteristics were measured according to the ISO2631-1 with each of the statuses: tubeless tires fixed and fluid in it (normal air or nitrogen and also the fluid in the tires fixed with tubes or tubeless on asphalt-paved road. Other variables including tire pressure, engine speed, road gradient, number of passengers, springs, and shock absorbers were kept constant. Then the effect of changes was analyzed using an appropriate statistical test. Results: After changing nitrogen to normal air and tubeless tires to tube, the average of RMS in Z-axis, eight-hour equivalent acceleration A(8 and crest factor were reduced (P 0.9 m/s2 to caution zone (0.45-0.9 m/s2 with a value of 0.8 m/s2. Conclusions: The amount of vibration transmitted to the whole body is sensitive to existence of tubes and tires inflation so that we can reduce the amount of whole-body vibration to lower than the upper limit of the health risk by changing the characteristics of the tire

  10. Relevance of whole body vibration exercise in sport: a short review ...

    African Journals Online (AJOL)

    Background: Whole body vibration exercise (WBVE) has been used as a safe and accessible exercise and important reviews have been published about the use of this exercise to manage diseases and to improve physical conditions of athletes The aim of this paper is to highlight the relevance of WBVE to soccer players, ...

  11. Stochastic resonance whole-body vibration improves postural control in health care professionals: a worksite randomized controlled trial.

    Science.gov (United States)

    Elfering, Achim; Schade, Volker; Stoecklin, Lukas; Baur, Simone; Burger, Christian; Radlinger, Lorenz

    2014-05-01

    Slip, trip, and fall injuries are frequent among health care workers. Stochastic resonance whole-body vibration training was tested to improve postural control. Participants included 124 employees of a Swiss university hospital. The randomized controlled trial included an experimental group given 8 weeks of training and a control group with no intervention. In both groups, postural control was assessed as mediolateral sway on a force plate before and after the 8-week trial. Mediolateral sway was significantly decreased by stochastic resonance whole-body vibration training in the experimental group but not in the control group that received no training (p < .05). Stochastic resonance whole-body vibration training is an option in the primary prevention of balance-related injury at work. Copyright 2014, SLACK Incorporated.

  12. Acute effects of whole body gamma irradiation on exocrine pancreatic secretion in the pig

    International Nuclear Information System (INIS)

    Monti, P.; Scanff, P.; Joubert, C.; Vergnet, M.; Grison, S.; Griffiths, N.

    2004-01-01

    Reports on radiation damage to the pancreas deal essentially with long-term morphological changes with few data on pancreatic exocrine function. The aim of this work was to study the acute effects of whole body irradiation on volume and enzyme activities in the pancreatic juice. A whole body gamma irradiation (6 Gy) was investigated in pigs with continuous sampling of pancreatic juice before and after exposure via an indwelling catheter in the pancreatic duct. For each sample collected, total protein concentration and enzyme activities of trypsin, chymotrypsin, elastase, lipase and amylase were determined. Pancreatic juice volume was monitored during all periods of collection. The volume of pancreatic juice secreted daily decreased one day after irradiation and remained lower than the control values over the experimental period. Total proteins secreted in the pancreatic juice and total activities of pancreatic enzymes were reduced similarly. On the other hand, only specific activities of elastase and lipase were affected by irradiation. Whole body gamma irradiation resulted in a rapid and marked decrease of exocrine pancreatic secretion, in terms of volume as well as secreted enzymes. This may contribute in part to the intestinal manifestations of the acute and/or late radiation syndrome. (author)

  13. Turnover of whole body proteins and myofibrillar proteins in middle-aged active men

    International Nuclear Information System (INIS)

    Zackin, M.; Meredith, C.; Frontera, W.; Evans, W.

    1986-01-01

    Endurance-trained older men have a higher proportion of lean tissue and greater muscle cell oxidative capacity, reversing age-related trends and suggesting major changes in protein metabolism. In this study, protein turnover was determined in 6 middle-aged (52+/-1 yr) men who were well trained (VO 2 max 55.2+/-5.0 ml O 2 /kg.min) and lean (body fat 18.9+/-2.8%, muscle mass 36.6+/-0.6%). The maintained habitual exercise while consuming 0.6, 0.9 or 1.2 g protein/kg.day for 10-day periods. N flux was measured from 15 N in urea after oral 15 N-glycine administration. Myofibrillar protein breakdown was estimated from urinary 3-methyl-histidine. Dietary protein had no effect on turnover rates, even when N balance was negative. Whole body protein synthesis was 3.60+/-0.12 g/kg.day and breakdown was 3.40+/-0.14 g/kg.day for all N intakes. Whole body protein flux, synthesis and breakdown were similar to values reported for sedentary young (SY) or sedentary old (SO) men on comparable diets. 3-me-his (3.67+/-0.14 μmol/kg.day) was similar to values reported for SY but higher (p<0.01) than for SO. Myofibrillar protein breakdown per unit muscle mass (185+/-7 μmol 3-me-his/g creatinine) was higher (p<0.01) than for SY or SO. In active middle-aged men, myofibrillar proteins may account for a greater proportion of whole body protein turnover, despite an age-related reduction in muscle mass

  14. Whole body computed tomographic findings of each one case with primary aldosteronism and Cushing syndrome

    International Nuclear Information System (INIS)

    Kamata, Shuji; Kawamura, Koro; Nakamura, Motoyuki

    1980-01-01

    We here report each one case with primary aldosteronism (male, 28 years old) and Cushing syndrome (female, 37 years old). Both of the cases showed characteristic clinical signs of hypertension and typical laboratory findings of adreno-hormonal assays. In performance of whole body computed tomography, clear pictures of tumorous adenomas in both cases were taken and the sizes of adenomas in picture were completely same as the masses obtained by the lateral adrenectomies. As a result, the whole body computed tomography is very useful to diagnose the diseases of adrenal adenoma and hyperplasia. (author)

  15. Estimation of whole body dose in an unusual event: spillage of radioactive material on the chair

    International Nuclear Information System (INIS)

    Adtani, M.M.; Biju, K.; Deshpande, M.D.; Shivde, R.K.; Kulkarni, V.V.

    2005-01-01

    The personnel monitoring in India is done using thermoluminescence dosimeters worn at chest level. In research institutions and in nuclear facilities where radiation sources are processed in dispersible forms, a remote possibility exists that radiation source entering in the area where installed monitor does not exist and the source may get spilled on chair and causing exposure to persons sitting on the chair. In such case TLD may not give the correct exposure as there is shielding of individuals body. An attempt is made to find out a factor for estimating the whole body dose by knowing the TLD badge dose or by measuring the gonad dose. Experiments are performed using TLDs and also measurement by teletector. Monte Carlo simulations are also done. It is observed that a factor of 8 to TLD Badge dose will give whole body dose if worker has received dose only on said chair or by applying a factor of 0.23 to dose measured at gonad level will give whole body dose. (author)

  16. I.R.D. annual report - 1988. Institute of Radioprotection and Dosimetry of Brazilian Nuclear Energy Commission (CNEN)

    International Nuclear Information System (INIS)

    1989-01-01

    This is the annual report of the activities developed by the Institute of Radioprotection and Dosimetry -IRD/CNEN-Brazil, in the year of 1988. It is composed by the individual reports of its several divisions, describing the main activities and personnel: DEPRO - Occupational and Radiological Protection Dept.; DEPRA - Environmental and Radiological Protection Dept.; DEMET - Metrology Dept.; DEPAT - Technical Support Dept.; DETAC - Scientific Support and Training Dept.; DEPAD -Administrative Support Dept. (J.A.M.M.)

  17. Identification of Motive Forces on the Whole Body System during Walking

    Directory of Open Access Journals (Sweden)

    Raghdan J. AlKhoury

    2010-01-01

    Full Text Available Motive forces by muscles are applied to different parts of the human body in a periodic fashion when walking at a uniform rate. In this study, the whole human body is modeled as a multidegree of freedom (MDOF system with seven degrees of freedom. In view of the changing contact conditions with the ground due to alternating feet movements, the system under study is considered piecewise time invariant for each half-period when one foot is in contact with the ground. Forces transmitted from the body to the ground while walking at a normal pace are experimentally measured and numerically simulated. Fourth-order Runge-Kutta method is employed to numerically simulate the forces acting on different masses of the body. An optimization problem is formulated with the squared difference between the measured and simulated forces transmitted to the ground as the objective function, and the motive forces on the body masses as the design variables to solve.

  18. A refined method for assessing sup(99m)Tc-MDP whole body retention in prostate cancer patients

    International Nuclear Information System (INIS)

    Castronovo, F.P. Jr.; Strauss, H.W.; McKusick, K.A.

    1987-01-01

    Whole body retention (WBR) of sup(99m)Tc labeled methylene diphosphonate (MDP) significantly differentiates various clinical stages of prostate cancer. Whole body measurements, when performed at 5 min and 24 h after i.v. administration of sup(99m)Tc-MDP, allows for the calculations of percentage whole body retention (% WBR) after one day. In an attempt to better describe the clinical course of prostate cancer patients with bone metastases we have refined the % WBR calculations to include a normalization factor. The latter consists of the mean 24-h value of WBR's as obtained from 10 prostate cancer patients without bony metastases as determined by bone scintigram. The % WBR is then divided by the normalization factor of choice and expressed as (% WRN)sup(N). These data are used to better express sup(99m)Tc MDP 24-h whole body retentions when following the clinical course of patients with metastatic carcinoma of the prostate. Caution should be exercised when interpreting these data when metabolic bone pathology is present. A false negative (% WBR)sup(N) value will result if an infiltration of the sup(99m)Tc-MDP occurs during administration. (author)

  19. Quantification of whole-body bradykinesia in Parkinson's disease participants using multiple inertial sensors.

    Science.gov (United States)

    Memar, Sara; Delrobaei, Mehdi; Pieterman, Marcus; McIsaac, Kenneth; Jog, Mandar

    2018-04-15

    Bradykinesia (slowness of movement) is a common motor symptom of Parkinson's disease (PD) that can severely affect quality of life for those living with the disease. Assessment and treatment of PD motor symptoms largely depends on clinical scales such as the Unified Parkinson's Disease Rating Scale (UPDRS). However, such clinical scales rely on the visual assessment by a human observer, naturally resulting in inter-rater variability. Although previous studies have developed objective means for measuring bradykinesia in PD patients, their evaluation was restricted by the type of movement and number of joints assessed. These studies failed to provide a more comprehensive, whole-body evaluation capable of measuring multiple joints simultaneously. This study utilizes wearable inertial measurement units (IMUs) to quantify whole-body movements, providing novel bradykinesia indices for walking (WBI) and standing up from a chair (sit-to-stand; SBI). The proposed bradykinesia indices include the joint angles at both upper and lower limbs and trunk motion to compute a complete, objective score for whole body bradykinesia. Thirty PD and 11 age-matched healthy control participants were recruited for the study. The participants performed two standard walking tasks that involved multiple body joints in the upper and lower limbs. The WBI and SBI successfully identified differences between control and PD participants. The indices also effectively identified differences within the PD population, distinguishing participants assessed with (ON) and without (OFF) levodopa; the gold-standard of treatment for PD. The goal of this study is to provide health professionals with an objective score for whole body bradykinesia by simultaneously measuring the upper and lower extremities along with truncal movement. This method demonstrates potential to be used in conjunction with current clinical standards for motor symptom assessment, and may also be promising for the remote assessment of PD

  20. Vestibular-somatosensory interactions: effects of passive whole-body rotation on somatosensory detection.

    Directory of Open Access Journals (Sweden)

    Elisa Raffaella Ferrè

    Full Text Available Vestibular signals are strongly integrated with information from several other sensory modalities. For example, vestibular stimulation was reported to improve tactile detection. However, this improvement could reflect either a multimodal interaction or an indirect interaction driven by vestibular effects on spatial attention and orienting. Here we investigate whether natural vestibular activation induced by passive whole-body rotation influences tactile detection. In particular, we assessed the ability to detect faint tactile stimuli to the fingertips of the left and right hand during spatially congruent or incongruent rotations. We found that passive whole-body rotations significantly enhanced sensitivity to faint shocks, without affecting response bias. Critically, this enhancement of somatosensory sensitivity did not depend on the spatial congruency between the direction of rotation and the hand stimulated. Thus, our results support a multimodal interaction, likely in brain areas receiving both vestibular and somatosensory signals.

  1. Evaluating the US Counter-ISIL Strategy

    Science.gov (United States)

    2017-05-25

    strategy is actually addressing those critical capabilities and vulnerabilities. Finally, it explores alternative, whole-of-government strategies that...Counterterrorism Strategies as an Illustration. Santa Monica, CA: RAND Corporation , 2009. Enduring Leadership in a Dynamic World. Quadrennial Diplomacy...Evaluating the US Counter-ISIL Strategy A Monograph by LTC Jason A. Curl U.S. Army School of Advanced Military Studies United States Army

  2. Comparison of the dose results in whole body and thyroid caused by 131 I using the software AIDE, DOSINT and ACCUSCAN

    International Nuclear Information System (INIS)

    Quintero P, E.; Alfaro L, M.M.

    2006-01-01

    Due to the sharp incorporation of 3.7 MBq of 131 I via oral for a patient, with the purpose of obtaining a thyroid gamma gram, it makes later a pursuit on to carry out the calculation of effective dose committed using the software AIDE, DOSINT and Accuscan that possesses the National Institute of Nuclear Research (ININ) and to compare the results of these. For this study it was carried out a pursuit of the biokinetic behavior of the radioisotope in the patient's body, measuring the activity with a whole-body counter of vertical sweeping, Canberra, model Accuscan Canberra trademark. The calibration of the system it was carried out using a RMC-II Canberra trademark phantom. The patient was accounted to different intervals of time starting from April 5 up to June 30, 2005. The Accuscan II program Canberra trademark, it was acquired with the whole-body system in 1992 by the ININ. The DOSINT program was elaborated by the National Commission of Nuclear Safety and Safeguards of Mexico and proportionate to the ININ in 2000. So much the DOSINT program as the Accuscan are based on the ICRP-26/30. The AIDE program was provided by the IAEA through the project IAEA-ARCAL-RLA/9/049-LXXVII - Harmonization of procedures of internal dosimetry in 2005. This program is based on the ICRP-78. The present activity in the urine was measured later starting from the third day of the incorporation of 131 I to different intervals of time until the 87 th day. The measurements were carried out using a gamma spectrometer with a Ge Hp detector and beryllium window, with 27.4% of relative efficiency and graduate armor-plating. The calibration of the system it was carried out using a multi nuclides pattern packed in Marinelli geometry of 0.5 L, prepared by the Laboratory of Radioactive Patterns (LPR) of the INlN starting from a certified solution. (Author)

  3. Whole body bone scintigraphy in osseous hydatosis: a case report

    Directory of Open Access Journals (Sweden)

    Ebrahimi Abdolali

    2007-09-01

    Full Text Available Abstract Hydatid disease is common in many parts of the world, and causes considerable health and economic loss. This disease may develop in almost any part of the body. Bone involvement is often asymptomatic, and its diagnosis is primarily based on radiographic findings. A whole body bone scan is able to show the extent and distribution of lesions. We describe an unusual case of multifocal skeletal hydatosis and also explain the clinical and diagnostic points. We hope to stimulate a high index of suspicion among clinicians to facilitate early diagnosis and to consider this disease as a differential diagnosis in cases of multiple abnormal activity in bone scintigraphy especially among people in endemic areas.

  4. Hilar activity on the F-18 FDG whole-body PET studies

    International Nuclear Information System (INIS)

    Fujii, Hirofumi; Kitamura, Masayuki; Kubo, Atsushi; Yasuda, Seiei; Ide, Michiru; Takahashi, Wakoh; Shohtsu, Akira

    1999-01-01

    We evaluated the clinical characteristics of hilar activity that would be false positive findings for cancer screening on whole-body FDG PET. The cases with increased hilar activity were selected from 1,126 cases who received whole-body FDG PET between September 1996 and August 1997, and their age, sex, complication of inflammatory process in lungs, numbers of visualized mediastinal lymph nodes, frequency of smoking, blood sugar level and concentration of HbA1c were studied. FDG accumulation in the hilar regions was found in 63 cases (5.6%). The cases with increased hilar activity were older, a higher incidence of complication of pulmonary inflammation, a larger number of visualized mediastinal lymph nodes and were more frequent smokers than the control cases with normal FDG distribution. Their male-to-female ratio, blood sugar level and concentration of HbA1c were not significantly different from those of the control cases. These results suggested that an inflammatory process around the hilar region might induce this confusing FDG accumulation. (author)

  5. The cesium -137 body burden of a control group in Stockholm, 1976

    International Nuclear Information System (INIS)

    Falk, R.; Eklund, G.

    1977-01-01

    Measurements of the 136 Cs content in a control group consisting of 20 - 30 persons have been carried out since 1959. Until 1966 the measurements were made in an 'open-both' type whole-body counter and after that in a three-crystal counter. Individual weighting factors for each member of the group is used to compensate for changes in the control group during the years. The calculation of the weighted mean of the cesium-137 level includes a correction for RaC contamination. During 1976 measurements were made on 24 members of the group, 14 men and 10 women. Measured content of potassium was 1.9+-0.3 g/kg body weight for the men and 1.6+-0.2 g/kg body weight for the women of the group. Tables show these results together with earlier results from the 'open-both' counter. The weighted mean and the highest and the lowest values within the group are indicated. The total error of the weighted mean and the highest value 1976 are about 15 percent and 12 percent respectively. For the last few years the cesium content has been below the detection limit, 10-15 pCi/gK, for some members of the group. (author)

  6. The influence of whole body 60Co-irradiation on distribution of 67Ga in tumor-bearing mice

    International Nuclear Information System (INIS)

    Wakao, Hiromi; Shimura, Akira; Higashi, Tomomitsu

    1981-01-01

    Since the initial findings that 67 Ga has a preferential affinity for soft tissue tumors, in humans numerous suggestions have been advanced for the basic mechanism involved. The effects produced by whole-body X-irradiation on the excretion and tissue distribution of 67 Ga have been reported by Swartzendruber and others. Bradley and coworkers have shown that these irradiation effects were associated with an increase in serum iron. The present investigation was undertaken in order to study the relationships between the change in the serum iron concentration and 67 Ga accumulation in the tumor and soft tissues in mice bearing Ehrlich's ascites tumor. The following results were obtained. (1) The serum iron concentration was significantly decreased between 3 and 6 hours after 10 Gy (1,000 rad) dose of whole-body 60 Co-irradiation. Subsequently, the serum iron levels were slowly elevated. (2) The uptake of 67 Ga in the tumor and soft tissues was increased if the serum iron concentration was decreased by whole-body 60 Co-irradiation during the early phase. On the contrary, if the serum iron concentration was high, the uptake of 67 Ga in the tumor was decreased. (3) The excretion of 67 Ga from the body was delayed if the serum iron concentration was decreased by whole-body 60 Co-irradiation. However, if the serum iron concentration was high, the excretion of 67 Ga from the body significantly increased. (author)

  7. Mechanisms of taurine hyperexcretion after whole-body irradiation of rats

    International Nuclear Information System (INIS)

    Beskrovnaya, L.A.; Lapteva, T.A.; Dokshina, G.A.; Baranova, M.I.

    1976-01-01

    Mechanisms of postirradiation hyperexcretion of taurine with urine have been investigated. In the course of three days after a whole-body exposure of rats (700 rads), the excretion of taurine increases. The experiments in vitro have demonstrated that taurine synthesis decreases in the thymus and liver of irradiated animals. The experiments conducted have shown that the postirradiation hyperexcretion of taurine is partly due to its release from the lymohoid tissue (thymus)

  8. Comparison of 99m-Tc-MDP and 99m-Tc-MIBI whole body scans for diagnosis of widespread skeletal metastases

    International Nuclear Information System (INIS)

    Ansari, M.; Hoshiar, A.; Mortazavi, S.H.

    2002-01-01

    Skeletal metastasis is one of the most important disabling complications of the malignant diseases. As in general, the survival of patients with osteometastatic lesions is relatively long, an early diagnosis can lead to improve the patient's life, both quantitatively and qualitatively and prevent exacerbation of the disease and disabling complications. In this study 22 patients with established diagnosis of malignant disease and clinical manifestations of skeletal metastasis were evaluated both with 99 m-Tc-MIBI and 99 m-Tc-MDP whole body scans, in two separate phases. Patient's diagnosis were as following: small round cell tumor, breast carcinoma. Nasopharynx carcinoma and multiple myeloma. In the first phase of the study a whole body bone scan was performed by IV injection of 740MBq 99 m-Tc-MDP. After a period of 1 week a whole body scan carried out by 99 m-Tc-MDP for all the patients. No treatment such as radiation therapy ar chemotherapy was done in this 1 week interval. The number and intensity of the scan findings were compared visually, according to the three- phase staging, subsequently. whole body survey with 99 m-Tc-MDP in 14 out 22 patient were positive demonstrating only 44.4% of body lesions established on whole body bone scan with 99 m-Tc-MDP. The mean value of intensity of radiotracer uptake was around 1.5+ (mild to moderate ). on the other hand in 7 patients with positive 99 m-Tc-MDP scan some hidden soft tissue lesions ( mostly lymph nodes) were detected with intensity of 2+. So this study shows that whole body bone scan is preferable for detection of widespread metastasis comparing with 99 m-Tc-MDP whole body scan. the significance of 99 m-Tc-MDP scan is mainly limited to some equivocal of soft tissue lesions

  9. Whole-body 35-GHz security scanner

    Science.gov (United States)

    Appleby, Roger; Anderton, Rupert N.; Price, Sean; Sinclair, Gordon N.; Coward, Peter R.

    2004-08-01

    A 35GHz imager designed for Security Scanning has been previously demonstrated. That imager was based on a folded conical scan technology and was constructed from low cost materials such as expanded polystyrene and printed circuit board. In conjunction with an illumination chamber it was used to collect indoor imagery of people with weapons and contraband hidden under their clothing. That imager had a spot size of 20mm and covered a field of view of 20 x 10 degrees that partially covered the body of an adult from knees to shoulders. A new variant of this imager has been designed and constructed. It has a field of view of 36 x 18 degrees and is capable of covering the whole body of an adult. This was achieved by increasing the number of direct detection receivers from the 32 used in the previous design to 58, and by implementing an improved optical design. The optics consist of a front grid, a polarisation device which converts linear to circular polarisation and a rotating scanner. This new design uses high-density expanded polystyrene as a correcting element on the back of the front grid. This gives an added degree of freedom that allows the optical design to be diffraction limited over a very wide field of view. Obscuration by the receivers and associated components is minimised by integrating the post detection electronics at the receiver array.

  10. Influence of 2,3-dimercaptosuccinic acid on gastrointestinal lead absorption and whole-body lead retention

    International Nuclear Information System (INIS)

    Kapoor, S.C.; Wielopolski, L.; Graziano, J.H.; LoIacono, N.J.

    1989-01-01

    2,3-Dimercaptosuccinic acid (DMSA) is a new orally active heavy metal chelator for the treatment of childhood Pb intoxication on an outpatient basis. The influence of DMSA, as well as other chelating agents, on gastrointestinal 203Pb absorption and whole-body 203 Pb retention was examined. Groups of Sprague-Dawley rats (230-260 g) were gavaged with a solution containing approximately 25 mg/kg Pb [as Pb(NO 3 )2] plus 15 microCi 203 Pb. Some groups were then immediately given 0.11 mmol/kg of either DMSA, CaNa2EDTA, D-penicillamine, or BAL by oral gavage, while other groups received the same drugs by ip injection. Control groups received solutions of the drug vehicles po or ip. Whole-body Pb retention and gastrointestinal Pb absorption (whole body retention + urinary Pb excretion) were significantly decreased in rats that received DMSA po. This finding implies that the use of DMSA to treat childhood lead intoxication on an outpatient basis is not associated with a risk for increased Pb absorption

  11. Whole-body muscle MRI in 20 patients suffering from late onset Pompe disease: Involvement patterns.

    Science.gov (United States)

    Carlier, Robert-Yves; Laforet, Pascal; Wary, Claire; Mompoint, Dominique; Laloui, Kenza; Pellegrini, Nadine; Annane, Djillali; Carlier, Pierre G; Orlikowski, David

    2011-11-01

    To describe muscle involvement on whole-body MRI scans in adult patients at different stages of late-onset Pompe disease. Twenty patients aged 37 to 75 were examined. Five were bedridden and required ventilatory support. Axial and coronal T1 turbo-spin-echo sequences were performed on 1.5T or 3T systems. MRI was scored for 47 muscles using Mercuri's classification. Whole-body scans were obtained with a mean in-room time of 29 min. Muscle changes consisted of internal bright signals of fatty replacement without severe retraction of the muscles' corpus. Findings were consistent with previous descriptions of spine extensors and pelvic girdle, but also provided new information on recurrent muscle changes particularly in the tongue and subscapularis muscle. Moreover thigh involvement was more heterogeneous than previously described, in terms of distribution across muscles as well as with respect to the overall clinical presentation. Whole-body MRI provides a very evocative description of muscle involvement in Pompe disease in adults. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Hippophae leaf extract (SBL-1) countered radiation induced dysbiosis in jejunum of total body 60Cobalt gamma - irradiated mice

    International Nuclear Information System (INIS)

    Beniwal, C.S.; Madhu Bala

    2014-01-01

    Single dose of SBL-1 administered at the rate 30 mg/kg body weight (b.w.) 30 min prior to whole body 60 Co-gamma-irradiation at lethal dose (10 Gy), rendered >90% survival in comparison to zero survival in the non-SBL-1 treated 60 Co-gamma-irradiated (10 Gy) mice population (J Herbs Spices Med Plants, 2009; 15(2): 203-215). Present study investigated the effect of SBL-1 on jejunal microbiota in lethally irradiated mice. Study was performed with inbred Swiss albino Strain 'A' male mice (age 9 weeks) weighing 28±2 g. The animals were maintained under controlled environment at 26±2℃; 12 h light/dark cycle and offered standard animal food (Golden feed, Delhi) as well as tap water ad libitum. Metagenomic DNA was extracted, purified and quantified from jejunum of the mice. Universal primers (27f and 1492r) were used to amplify the 16S rRNA DNA from the metagenomic DNA. Amplicons were sequenced, vector contamination and chimeras were removed. The sequences (GenBank Accession No: KF681283 to KF681351) were taxonomically classified by using Sequence Match program, Ribosomal Database Project as well as by nucleotide-BLAST (E-value: 10, database: 16S rRNA gene sequences, Bacteria and Archea). Phylogenetic Tree was prepared using MEGA 5.2 package, using maximum likelihood algorithm after sequence alignment by MUSCLE. Thermus aquaticus was used as out-group to construct rooted tree. Branch stability was assessed by bootstrap analysis. Untreated animals and the animals treated with SBL-1 had 100% Lactobacillus; 60 Co gamma-irradiated animals had 55% Cohaesibacter (Alphaproteobacteria); 27% Mycoplasma (Tenericutes) and only 18% Lactobacillus; animals treated with SBL-1 prior to irradiation had 89% Lactobacillus and 11% Clostridium. This study demonstrated that treatment with SBL-1 at radioprotective doses before total body irradiation with lethal dose (10 Gy) countered the jejunal dysbiosis. (author)

  13. Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET

    NARCIS (Netherlands)

    Karakatsanis, Nicolas A.; Zhou, Yun; Lodge, Martin A.; Casey, Michael E.; Wahl, Richard L.; Zaidi, Habib; Rahmim, Arman

    2015-01-01

    We recently developed a dynamic multi-bed PET data acquisition framework to translate the quantitative benefits of Patlak voxel-wise analysis to the domain of routine clinical whole-body (WB) imaging. The standard Patlak (sPatlak) linear graphical analysis assumes irreversible PET tracer uptake,

  14. Prolonged whole-body cold water immersion: fluid and ion shifts.

    Science.gov (United States)

    Deuster, P A; Smith, D J; Smoak, B L; Montgomery, L C; Singh, A; Doubt, T J

    1989-01-01

    To characterize fluid and ion shifts during prolonged whole-body immersion, 16 divers wearing dry suits completed four whole-body immersions in 5 degrees C water during each of two 5-day air saturation dives at 6.1 msw. One immersion was conducted at 1000 (AM) and one at 2200 (PM) so that diurnal variations could be evaluated. Fifty-four hours separated the immersions, which lasted up to 6 h; 9 days separated each air saturation dive. Blood was collected before and after immersion; urine was collected for 12 h before, during, and after immersion for a total of 24 h. Plasma volume decreased significantly and to the same extent (approximately 17%) during both AM and PM immersions. Urine flow increased by 236.1 +/- 38.7 and 296.3 +/- 52.0%, urinary excretion of Na increased by 290.4 +/- 89.0 and 329.5 +/- 77.0%, K by 245.0 +/- 73.4 and 215.5 +/- 44.6%, Ca by 211.0 +/- 31.4 and 241.1 +/- 50.4%, Mg by 201.4 +/- 45.9 and 165.3 +/- 287%, and Zn by 427.8 +/- 93.7 and 301.9 +/- 75.4% during AM and PM immersions, respectively, compared with preimmersion. Urine flow and K excretion were significantly higher during the AM than PM. In summary, when subjects are immersed in cold water for prolonged periods, combined with a slow rate of body cooling afforded by thermal protection and enforced intermittent exercise, there is diuresis, decreased plasma volume, and increased excretions of Na, K, Ca, Mg, and Zn.

  15. Acid base balance in the rabbit following whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Bassant, M.-H.; Touchard, Francoise; Court, Louis

    1981-01-01

    2 hrs. after whole-body gamma irradiation (doses of 1.5 and 4.5 Gy) a metabolic acidosis developed in curarised Rabbits placed under artificial respiration in order to eliminate radiation-induced respiratory effect. The metabolic acidosis was evaluated by measurement of the negative base excess. The results were compared to others obtained under different experimental procedures [fr

  16. Acid base balance in the rabbit following whole-body gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bassant, M.H.; Touchard, F.; Court, L. (CEA Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Recherches sur la Fusion Controlee)

    1981-07-06

    2 hrs. after whole-body gamma irradiation (doses of 1.5 and 4.5 Gy) a metabolic acidosis developed in curarised rabbits placed under artificial respiration in order to eliminate radiation-induced respiratory effect. The metabolic acidosis was evaluated by measurement of the negative base excess. The results were compared to others obtained under different experimental procedures.

  17. Whole-body γ-irradiation effects on catecholamine concentration in animal tissues

    International Nuclear Information System (INIS)

    Makashev, Zh.K.; Uteshev, T.A.; Abylaev, Zh. A.; Zhurnist, A.G.

    2003-01-01

    On the whole-body gamma-radiation activity in the exchanges of catecholamines (adrenalin and non-adrenalin) and their predecessors (dopamine and DOPA) in the rats tissue organism, indicate the infringement of irradiated animals in different links of biological synthesis the bio-gen amines in different phases of the radiation: DOPA→dopamine, dopamine→adrenalin, adrenalin→non-adrenalin. (author)

  18. Whole- and partial-body cryostimulation/cryotherapy: Current technologies and practical applications.

    Science.gov (United States)

    Bouzigon, Romain; Grappe, Frederic; Ravier, Gilles; Dugue, Benoit

    2016-10-01

    Cold therapy is commonly used as a method to relieve pain and inflammation. This review focuses primarily on two methods of cold therapy that have received recent attention: whole-body cryotherapy and partial-body cryotherapy. These methods are used to induce physiological and psychological benefits in humans in the context of medicine, health and sports. The subjects experiencing cryotherapy are dressed in minimal clothing and are exposed to very cold air (at -110°C or less) for 1-4min. Despite the increasing scientific interest in these methods, there is a lack of information about the technologies used. Moreover, there is no existing reference concerning exposure protocols and the relationship between temperature, duration, number of repetitions and the treatments' desired effects. The aim of this review is to compare whole- and partial-body cryotherapy effects (especially on skin temperature) and to classify the protocols for exposure according to the desired effects. This review emphasises 1) the lack of information concerning the actual temperatures inside the cabin or chamber during exposure and 2) the heterogeneity among the exposure protocols that have been reported in the scientific literature. This review will be valuable and relevant to health professionals endeavouring to optimize the cold treatments offered to patients and producers of cryotherapy apparatus striving to create more efficient devices that meet market requirements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Thirty years after the radiation accident in Goiânia: the IRD and the learning in the face of tragedy

    International Nuclear Information System (INIS)

    Jansen, L.C.; Razuck, F.B.

    2017-01-01

    The objective of the article is to present some contributions to the learning in the radioprotection area from Goiania accident. A thematic workshop was held, together with the students of the Specialization Course in Radiological Protection and Security of Radioactive Sources, offered by the Institute of Radioprotection and Dosimetry (IRD) and the International Atomic Energy Agency (IAEA), focusing on the IRD action during the accident. Some teachers of the course gave a testimony on what was the greatest legacy of the accident for the radioprotection area. From the analysis of the speeches, a workshop was held to discuss the relevance of the accident. It was sought to evidence the radiological accident as a learning tool in the field of nuclear science, opening space for discussions of a wider knowledge about ionizing radiation. Thus, it is not possible to deny the technological advance and the learning originated from this tragedy in Brazilian soil, understanding that the investigations related to historical aspects of science end up leading to new implications in the teaching of sciences

  20. [Psychological effects of long-term occupational whole body vibration].

    Science.gov (United States)

    Schneider, H; Wall, H

    1989-04-01

    Long-term effects of occupational whole-body vibration (WBV) on psychic performance and on well-being have hardly been described in the literature to date. However, they cannot be excluded, since numerous findings exist on impairments of performance and of well-being in experimentally conditioned short-term effects. Within the framework of comprehensive clearing-up diagnostics in occupational health, 20 male subjects with many years of occupational exposure to WBV were investigated according to a standardized psychodiagnostic programme of methods. The highest rate of pathological findings resulted in the areas of visual perception speed and subtle motory speed of movements. Furthermore, the results are evidence for an interrelation between the duration of exposure and disturbances in the areas of attention, as well as of sensomotory selection responses. As a whole, the results essentially affect the same psychological variables as the results of the short-term studies, but are to be evaluated with reservations on methodological grounds.

  1. Computational Fluid Dynamics of Whole-Body Aircraft

    Science.gov (United States)

    Agarwal, Ramesh

    1999-01-01

    The current state of the art in computational aerodynamics for whole-body aircraft flowfield simulations is described. Recent advances in geometry modeling, surface and volume grid generation, and flow simulation algorithms have led to accurate flowfield predictions for increasingly complex and realistic configurations. As a result, computational aerodynamics has emerged as a crucial enabling technology for the design and development of flight vehicles. Examples illustrating the current capability for the prediction of transport and fighter aircraft flowfields are presented. Unfortunately, accurate modeling of turbulence remains a major difficulty in the analysis of viscosity-dominated flows. In the future, inverse design methods, multidisciplinary design optimization methods, artificial intelligence technology, and massively parallel computer technology will be incorporated into computational aerodynamics, opening up greater opportunities for improved product design at substantially reduced costs.

  2. Safety aspects of whole-body cryochamber and cryosauna operation

    Science.gov (United States)

    Agnieszka, Piotrowska

    2017-12-01

    Interest in low temperature treatment is constantly increasing. Whole-body cryotherapy (WBC) devices are becoming available not only in medical centers but also in local gyms and spa centers. A new group of users are professional sport clubs where 3-minutes session of whole-body cryotherapy is post-training procedure to improve and speed up the recovery process. There are four different types of WBC devices available on the market and offered to commercial (non-medical) users. The American and European market is dominated by two of them: classic cryochambers and cryosaunas. Both constructions are supplied with liquid nitrogen. Low temperature inside classic cryochamber is produced by evaporating of liquid nitrogen in two or more heat exchangers. There is never a direct contact between user and cryogenic medium in any of system operation mode (closed supply system). Cryosauna is cooled down by filling with cold vapor of liquid nitrogen. Supply system is considered open because it allows for direct contact between user and cryogenic medium. Open supply system of cryosauna is primary and most questionable issue of its operational safety, particularly after tragic accident in October 2015. This paper presents the comparative analysis of classic cryochamber and cryosauna from safety point of view. Both devices have been analyzes and tested on existing systems in operation. Paper gives detailed analysis of constructions, supply systems and working parameters. Special attention has been focused to problem of oxygen deficiency hazard. Different failure or accident scenarios have been analyzed and discussed.

  3. Effect of abomasal glucose infusion on splanchnic and whole-body glucose metabolism in periparturient dairy cows

    DEFF Research Database (Denmark)

    Larsen, Mogens; Kristensen, Niels Bastian

    2009-01-01

    Six periparturient Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the hepatic portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic and whole-body glucose metabolism.......Six periparturient Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the hepatic portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic and whole-body glucose metabolism....

  4. Targeted microbubbles for imaging tumor angiogenesis: assessment of whole-body biodistribution with dynamic micro-PET in mice

    DEFF Research Database (Denmark)

    Willmann, Jürgen K; Cheng, Zhen; Davis, Corrine

    2008-01-01

    To evaluate in vivo whole-body biodistribution of microbubbles (MBs) targeted to tumor angiogenesis-related vascular endothelial growth factor (VEGF) receptor 2 (VEGFR2) by using dynamic micro-positron emission tomography (PET) in living mice.......To evaluate in vivo whole-body biodistribution of microbubbles (MBs) targeted to tumor angiogenesis-related vascular endothelial growth factor (VEGF) receptor 2 (VEGFR2) by using dynamic micro-positron emission tomography (PET) in living mice....

  5. Vibration energy absorption in the whole-body system of a tractor operator.

    Science.gov (United States)

    Szczepaniak, Jan; Tanaś, Wojciech; Kromulski, Jacek

    2014-01-01

    Many people are exposed to whole-body vibration (WBV) in their occupational lives, especially drivers of vehicles such as tractor and trucks. The main categories of effects from WBV are perception degraded comfort interference with activities-impaired health and occurrence of motion sickness. Absorbed power is defined as the power dissipated in a mechanical system as a result of an applied force. The vibration-induced injuries or disorders in a substructure of the human system are primarily associated with the vibration power absorption distributed in that substructure. The vibration power absorbed by the exposed body is a measure that combines both the vibration hazard and the biodynamic response of the body. The article presents measurement method for determining vibration power dissipated in the human whole body system called Vibration Energy Absorption (VEA). The vibration power is calculated from the real part of the force-velocity cross-spectrum. The absorbed power in the frequency domain can be obtained from the cross-spectrum of the force and velocity. In the context of the vibration energy transferred to a seated human body, the real component reflects the energy dissipated in the biological structure per unit of time, whereas the imaginary component reflects the energy stored/released by the system. The seated human is modeled as a series/parallel 4-DOF dynamic models. After introduction of the excitation, the response in particular segments of the model can be analyzed. As an example, the vibration power dissipated in an operator has been determined as a function of the agricultural combination operating speed 1.39 - 4.16 ms(-1).

  6. Early diagnosis and monitoring of whole-body accidental exposure

    International Nuclear Information System (INIS)

    Flury-Herard, A.; Jullien, D.

    1987-01-01

    This paper deals with the handling of accidental, acute or protracted, whole-body overexposures. It is complementary to the report DPS 86/07 SEAPS previously published. The criteria for initial classification, as a function of the mean absorbed dose, the clinical and paraclinical evaluation, the monitoring methods and the treatments to undertake are described successively. The basic components of the therapy are the intensive care of the hematological syndrome with blood products transfusions and anti-infection prophylaxy. The indications and conditions for bone-marrow grafts are also discussed [fr

  7. Beneficial effects of the whole-body cryotherapy on sport haemolysis

    OpenAIRE

    Banfi, Giuseppe; Melegati, Gianluca; Barassi, Alessandra; Melzi d'Eril, Gianvico

    2009-01-01

    Background. Sport's anemia is a common risk for athletes. The principal source of an accelerated turnover of the erythrocytes in sportsmen is the intravascular hemolysis. This phenomenon is induced by mechanical breakage for impact of feet and muscular contractions, but also by osmotic changes causing membrane fragility, typically evident after exercise, when free radicals are increased. Whole-body cryotherapy (WBC) covers a wide range of therapeutic applications and consists of briefly expos...

  8. Assessment of Whole Body and Local Muscle Fatigue Using Electromyography and a Perceived Exertion Scale for Squat Lifting

    Directory of Open Access Journals (Sweden)

    Imran Ahmad

    2018-04-01

    Full Text Available This research study aims at addressing the paradigm of whole body fatigue and local muscle fatigue detection for squat lifting. For this purpose, a comparison was made between perceived exertion with the heart rate and normalized mean power frequency (NMPF of eight major muscles. The sample consisted of 25 healthy males (age: 30 ± 2.2 years. Borg’s CR-10 scale was used for perceived exertion for two segments of the body (lower and upper and the whole body. The lower extremity of the body was observed to be dominant compared to the upper and whole body in perceived response. First mode of principal component analysis (PCA was obtained through the covariance matrix for the eight muscles for 25 subjects for NMPF of eight muscles. The diagonal entries in the covariance matrix were observed for each muscle. The muscle with the highest absolute magnitude was observed across all the 25 subjects. The medial deltoid and the rectus femoris muscles were observed to have the highest frequency for each PCA across 25 subjects. The rectus femoris, having the highest counts in all subjects, validated that the lower extremity dominates the sense of whole body fatigue during squat lifting. The findings revealed that it is significant to take into account the relation between perceived and measured effort that can help prevent musculoskeletal disorders in repetitive occupational tasks.

  9. Assessment of Whole Body and Local Muscle Fatigue Using Electromyography and a Perceived Exertion Scale for Squat Lifting.

    Science.gov (United States)

    Ahmad, Imran; Kim, Jung-Yong

    2018-04-18

    This research study aims at addressing the paradigm of whole body fatigue and local muscle fatigue detection for squat lifting. For this purpose, a comparison was made between perceived exertion with the heart rate and normalized mean power frequency (NMPF) of eight major muscles. The sample consisted of 25 healthy males (age: 30 ± 2.2 years). Borg’s CR-10 scale was used for perceived exertion for two segments of the body (lower and upper) and the whole body. The lower extremity of the body was observed to be dominant compared to the upper and whole body in perceived response. First mode of principal component analysis (PCA) was obtained through the covariance matrix for the eight muscles for 25 subjects for NMPF of eight muscles. The diagonal entries in the covariance matrix were observed for each muscle. The muscle with the highest absolute magnitude was observed across all the 25 subjects. The medial deltoid and the rectus femoris muscles were observed to have the highest frequency for each PCA across 25 subjects. The rectus femoris, having the highest counts in all subjects, validated that the lower extremity dominates the sense of whole body fatigue during squat lifting. The findings revealed that it is significant to take into account the relation between perceived and measured effort that can help prevent musculoskeletal disorders in repetitive occupational tasks.

  10. High-intensity interval training using whole-body exercises: training recommendations and methodological overview.

    Science.gov (United States)

    Machado, Alexandre F; Baker, Julien S; Figueira Junior, Aylton J; Bocalini, Danilo S

    2017-05-04

    HIIT whole body (HWB)-based exercise is a new calisthenics exercise programme approach that can be considered an effective and safe method to improve physical fitness and body composition. HWB is a method that can be applied to different populations and ages. The purpose of this study was to describe possible methodologies for performing physical training based on whole-body exercise in healthy subjects. The HWB sessions consist of a repeated stimulus based on high-intensity exercise that also include monitoring time to effort, time to recuperation and session time. The exercise intensity is related to the maximal number of movements possible in a given time; therefore, the exercise sessions can be characterized as maximal. The intensity can be recorded using ratings of perceived exertion. Weekly training frequency and exercise selection should be structured according to individual subject functional fitness. Using this simple method, there is potential for greater adherence to physical activity which can promote health benefits to all members of society. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  11. Whole-body distribution and dosimetry of O-(2-[{sup 18}F]fluoroethyl)-l-tyrosine

    Energy Technology Data Exchange (ETDEWEB)

    Pauleit, Dirk [Clinic of Nuclear Medicine, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany); Clinic of Nuclear Medicine, Research Center Juelich, P.O. Box 1913, 52425, Juelich (Germany); Floeth, Frank [Department of Neurosurgery, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany); Herzog, Hans; Tellmann, Lutz; Langen, Karl-J. [Institute of Medicine, Research Center Juelich, Juelich (Germany); Hamacher, Kurt; Coenen, Heinz H. [Institute of Nuclear Chemistry, Research Center Juelich, Juelich (Germany); Mueller, Hans-W. [Clinic of Nuclear Medicine, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany)

    2003-04-01

    The whole-body distribution of O-(2-[{sup 18}F]fluoroethyl)-l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV {<=}1.6) which remained constant between early and late PET scans. No increased uptake was seen in the bone, the biliary tract or the pancreas. Twenty-two percent of the injected activity was excreted 5 h p.i. (approx. 5.3% ID/h). The highest absorbed dose was found for the urinary bladder wall. The effective dose according to ICRP 60 was 16.5 {mu}Sv/MBq for adults, which would lead to an effective dose of 6.1 mSv in a PET study using 370 MBq FET. (orig.)

  12. The role of embodied simulation in mental transformation of whole-body images: evidence from Parkinson's disease.

    Science.gov (United States)

    Conson, Massimiliano; Trojano, Luigi; Vitale, Carmine; Mazzarella, Elisabetta; Allocca, Roberto; Barone, Paolo; Grossi, Dario; Santangelo, Gabriella

    2014-02-01

    It has been repeatedly demonstrated that mentally performing an action and mentally transforming body-parts entail simulation of one's own body movements, consistent with predictions of embodied cognition theories. However, the involvement of embodied simulation in mental transformation of whole-body images is still disputed. Here, we assessed own body transformation in Parkinson's disease (PD) patients with symptoms most affecting the left or the right body side. PD patients were required to perform left-right judgments on front-facing or back-facing human figures, and a letter rotation task. Results demonstrated that PD patients were selectively impaired in judging the side of back-facing human figures corresponding to their own most affected side, but performed as well as healthy subjects on mental transformation of front-facing bodies and on letter rotation. These findings demonstrate a parallel impairment between motor and mental simulation mechanisms in PD patients, thus highlighting the specific contribution of embodied cognition to mental transformation of whole-body images. Copyright © 2014. Published by Elsevier B.V.

  13. Optimization of whole-body PET imaging protocol for the detection of 18F-FDG overlappings in oncology

    International Nuclear Information System (INIS)

    Lartizien, C.

    2001-01-01

    Positron emission tomography (PET) is a nuclear imaging modality that allows studying in vivo cellular metabolic and biochemical processes. During the 90's, there has been a growing interest in the applications of PET in oncology related to the use of a glucose analog (FDG) labeled with the positron emitter 18 F. This tracer of the glucose metabolism is trapped in the cancer cells characterized by a deregulated glycolytic activity. This allows detecting tumors and metastases. The interest of PET in oncology has lead to develop imaging systems and protocols to perform whole-body acquisitions of the patient. Whole-body PET imaging has been limited in practice by the high level of statistical noise that affects the detection of small lesions due to limited radioactive dose injected to the patient and short acquisition time. In this context, our work focused on the optimization of detection performances in whole-body 18 F-FDG PET images. We have first developed an original method to evaluate detectability based on the psychophysical approach of the ROC methodology and adapted to the specificity of whole-body PET images. This method was used to evaluate detection performances of different reconstruction algorithms used for whole-body imaging. We have also studied the influence of the acquisition mode, namely the 2D and the 3D modes. To that purpose, we have used the NEC index to select relevant statistical acquisition conditions in both acquisition modes as a function of the injected dose to the patient. Then, we have compared the detection performances of these different acquisition conditions based on our psychophysical evaluation technique. (author) [fr

  14. Is whole body bone mineral density measured by the dual energy X-ray absorptiometry applied to evaluate risk of osteoporosis among Japanese adult females?

    International Nuclear Information System (INIS)

    Sakai, Yumiko; Koike, George; Numata, Makoto; Taneda, Kiyoshi; Jingu, Sumie

    2010-01-01

    The purpose of this study is to measure whole body fat accurately, the dual energy X-ray absorptiometry (DXA) is widely utilized. Simultaneously, bone mineral density (BMD) of the whole body can also be measured. BMD is one of important information to diagnose osteoporosis. However, it is not established to use whole body BMD for this diagnosis. It is recommended that lumbar and/or hip BMD should be used for diagnosing osteoporosis by the guideline for prevention and treatment of osteoporosis. Although it is possible to measure whole body BMD and lumbar and/or hip BMD separately at the same visit, it is inevitable to expose patients to more X-ray. Therefore, an aim of this study is to elucidate the relationship between whole body BMD and lumbar BMD to find the cut off point of whole body BMD for screening of osteoporosis. Two hundred and thirty six Japanese adult females were ascertained to this study. Whole body BMD and lumbar BMD of each subject were measured with the use of Delphi W (Hologic, USA). One hundred and sixty five subjects were judged as possible osteoporosis (less than 80% of young adult mean (YAM) of lumbar BMD and/or definite fracture of lumbar vertebras). The cut off point of whole body BMD for screening possible osteoporosis was estimated by receiver operated characteristic (ROC) analysis. The cut off point of whole body BMD was 84% of YAM, equivalent to 80% of YAM of lumbar BMD, with the following sensitivity and specificity (0.84 and 0.79, respectively), indicating that whole body BMD could be used for screening osteoporosis. (author)

  15. A COMPARATIVE STUDY OF WHOLE-BODY VIBRATION EXPOSURE IN TRAIN AND CAR PASSENGERS: A CASE STUDY IN MALAYSIA

    Directory of Open Access Journals (Sweden)

    M.M. Rahman

    2011-12-01

    Full Text Available Trains and cars are the most important modes of transportation throughout the world. In highly developed countries, trains have become essential for human use as the most well-known form of public transportation, whereas the car plays a significant role in prompt human travel from one place to another. The high magnitude of vibration caused by trains and cars may cause health problems in humans, especially low back pain. The aim of this study was to evaluate and validate the values of daily exposure to vibration A(8 and the vibration dose value (VDV in passengers travelling by train and car and to assess the effects produced by this exposure on the human body. Moreover, this study introduces a newly developed whole-body vibration measurement instrumentation system. One train travelling from the east coast to the south of Malaysia was chosen to conduct the study. Whole-body vibration exposure was measured over 8 hours, which is equal to the duration of normal occupational exposure. One car was chosen randomly and whole-body vibration exposure was measured for 5 min and 10 min. All the data were computed using an IEPE(ICPTM accelerometer sensor connected to a DT9837 device which is capable of effectively measuring and analysing vibration. The vibration results were displayed on a personal computer using a custom graphical user interface (GUI. Matlab software was used to interpret the data. From the results, the whole-body vibration exposure level could be determined. It can be concluded that the whole-body vibration absorbed by the human body is enhanced when the magnitude of the vibration exposure experienced by the passengers increased. This was shown by the increased values of daily exposure to vibration A(8 and VDV calculated in the study.

  16. Effects of local and whole body irradiation on appearance of osteoclasts during wound healing of tooth extraction sockets in rats

    International Nuclear Information System (INIS)

    Hosokawa, Yoichiro; Sakakura, Yasunori; Tanaka, Likinobu; Okumura, Kazuhiko; Yajima, Toshihiko; Kaneko, Masayuki

    2007-01-01

    We examined effects of local and whole body irradiation before tooth extraction on appearance and differentiation of osteoclasts in the alveolar bone of rat maxillary first molars. Wistar rats weighting 100 g were divided into three groups: non-irradiation group, local irradiation group, and whole body irradiation group. In the local irradiation group, a field made with lead blocks was placed over the maxillary left first molar tooth. In the whole body irradiation group, the animals were irradiated in cages. Both groups were irradiated at 8 Gy. The number of osteoclasts around the interradicular alveolar bone showed chronological changes common to non-irradiated and irradiated animals. Several osteoclasts appeared one day after tooth extraction, and the maximal peak was observed 3 days after extraction. Local irradiation had no difference from non-irradiated controls. In animals receiving whole body irradiation, tooth extraction one day after irradiation caused smaller number of osteoclasts than that 7 day after irradiation during the experimental period. Whole body-irradiated rats had small osteoclasts with only a few nuclei and narrow resorption lacunae, indicating deficiency of radioresistant osteoclast precursor cells. Injection of intact bone marrow cells to whole body-irradiated animals immediately after tooth extraction recovered to some content the number of osteoclasts. These findings suggest that bone resorption in the wound healing of alveolar socket requires radioresistant, postmitotic osteoclast precursor cells from hematopoietic organs, but not from local sources around the alveolar socket, at the initial phase of wound healing. (author)

  17. Effects of local and whole body irradiation on appearance of osteoclasts during wound healing of tooth extraction sockets in rats.

    Science.gov (United States)

    Hosokawa, Yoichiro; Sakakura, Yasunori; Tanaka, Likinobu; Okumura, Kazuhiko; Yajima, Toshihiko; Kaneko, Masayuki

    2007-07-01

    We examined effects of local and whole body irradiation before tooth extraction on appearance and differentiation of osteoclasts in the alveolar bone of rat maxillary first molars. Wistar rats weighting 100 g were divided into three groups: non-irradiation group, local irradiation group, and whole body irradiation group. In the local irradiation group, a field made with lead blocks was placed over the maxillary left first molar tooth. In the whole body irradiation group, the animals were irradiated in cages. Both groups were irradiated at 8 Gy. The number of osteoclasts around the interradicular alveolar bone showed chronological changes common to non-irradiated and irradiated animals. Several osteoclasts appeared one day after tooth extraction, and the maximal peak was observed 3 days after extraction. Local irradiation had no difference from non-irradiated controls. In animals receiving whole body irradiation, tooth extraction one day after irradiation caused smaller number of osteoclasts than that 7 day after irradiation during the experimental period. Whole body-irradiated rats had small osteoclasts with only a few nuclei and narrow resorption lacunae, indicating deficiency of radioresistant osteoclast precursor cells. Injection of intact bone marrow cells to whole body-irradiated animals immediately after tooth extraction recovered to some content the number of osteoclasts. These findings suggest that bone resorption in the wound healing of alveolar socket requires radioresistant, postmitotic osteoclast precursor cells from hematopoietic organs, but not from local sources around the alveolar socket, at the initial phase of wound healing.

  18. Influence of pregnancy stage and fetus position on the whole-body and local exposure of the fetus to RF-EMF

    International Nuclear Information System (INIS)

    Varsier, N; Wiart, J; Dahdouh, S; Angelini, E D; Bloch, I; Serrurier, A; De la Plata, J-P; Anquez, J

    2014-01-01

    This paper analyzes the influence of pregnancy stage and fetus position on the whole-body and brain exposure of the fetus to radiofrequency electromagnetic fields. Our analysis is performed using semi-homogeneous pregnant woman models between 8 and 32 weeks of amenorrhea. By analyzing the influence of the pregnancy stage on the environmental whole-body and local exposure of a fetus in vertical position, head down or head up, in the 2100 MHz frequency band, we concluded that both whole-body and average brain exposures of the fetus decrease during the first pregnancy trimester, while they advance during the pregnancy due to the rapid weight gain of the fetus in these first stages. From the beginning of the second trimester, the whole-body and the average brain exposures are quite stable because the weight gains are quasi proportional to the absorbed power increases. The behavior of the fetus whole-body and local exposures during pregnancy for a fetus in the vertical position with the head up were found to be of a similar level, when compared to the position with the head down they were slightly higher, especially in the brain. (paper)

  19. Whole body MRI in the diagnosis of chronic recurrent multifocal osteomyelitis.

    LENUS (Irish Health Repository)

    Kennedy, M T

    2012-06-01

    Chronic recurrent multifocal osteomyelitis (CRMO) is a diagnosis of exclusion primarily in children and adolescents. As part of the essential criteria for the diagnosis of CRMO, multifocal lesions must be identified. We present the case of an 11-year-old boy with CRMO, whose diagnosis was facilitated by the use of whole body magnetic resonance imaging (WBMR), but not isotope bone scanning.

  20. Effect of whole body resistance training on arterial compliance in young men.

    NARCIS (Netherlands)

    Rakobowchuk, M.; McGowan, C.L.; Groot, P.C.E. de; Bruinsma, D.; Hartman, J.W.; Phillips, S.M.; MacDonald, M.J.

    2005-01-01

    The effect of resistance training on arterial stiffening is controversial. We tested the hypothesis that resistance training would not alter central arterial compliance. Young healthy men (age, 23 +/- 3.9 (mean +/- s.e.m.) years; n = 28,) were whole-body resistance trained five times a week for 12

  1. DETECTION OF WHOLE BODY OXIDATIVE STRESS IN URINE USING OXYGEN-18 LABELING

    Science.gov (United States)

    DETECTION OF WHOLE BODY OXIDATIVE STRESS IN URINE USING OXYGEN-18 LABELING. R Slade, J L McKee and G E Hatch. PTB, ETD, NHEERL, ORD, USEPA, Research Triangle Park, NC, USA.Reliable non-invasive markers for detecting oxidative stress in vivo are currently not available. We pr...

  2. Estimation of normal hydration in dialysis patients using whole body and calf bioimpedance analysis

    International Nuclear Information System (INIS)

    Zhu, Fansan; Kotanko, Peter; Handelman, Garry J; Raimann, Jochen G; Liu, Li; Carter, Mary; Kuhlmann, Martin K; Seibert, Eric; Levin, Nathan W; Leonard, Edward F

    2011-01-01

    Prescription of an appropriate dialysis target weight (dry weight) requires accurate evaluation of the degree of hydration. The aim of this study was to investigate whether a state of normal hydration (DW cBIS ) as defined by calf bioimpedance spectroscopy (cBIS) and conventional whole body bioimpedance spectroscopy (wBIS) could be characterized in hemodialysis (HD) patients and normal subjects (NS). wBIS and cBIS were performed in 62 NS (33 m/29 f) and 30 HD patients (16 m/14 f) pre- and post-dialysis treatments to measure extracellular resistance and fluid volume (ECV) by the whole body and calf bioimpedance methods. Normalized calf resistivity (ρ N,5 ) was defined as resistivity at 5 kHz divided by the body mass index. The ratio of wECV to total body water (wECV/TBW) was calculated. Measurements were made at baseline (BL) and at DW cBIS following the progressive reduction of post-HD weight over successive dialysis treatments until the curve of calf extracellular resistance is flattened (stabilization) and the ρ N,5 was in the range of NS. Blood pressures were measured pre- and post-HD treatment. ρ N,5 in males and females differed significantly in NS. In patients, ρ N,5 notably increased with progressive decrease in body weight, and systolic blood pressure significantly decreased pre- and post-HD between BL and DW cBIS respectively. Although wECV/TBW decreased between BL and DW cBIS , the percentage of change in wECV/TBW was significantly less than that in ρ N,5 (−5.21 ± 3.2% versus 28 ± 27%, p < 0.001). This establishes the use of ρ N,5 as a new comparator allowing a clinician to incrementally monitor removal of extracellular fluid from patients over the course of dialysis treatments. The conventional whole body technique using wECV/TBW was less sensitive than the use of ρ N,5 to measure differences in body hydration between BL and DW cBIS

  3. Clinical evaluation of exercise thallium-201 whole body scintigraphy in ischemic heart disease

    International Nuclear Information System (INIS)

    Kaneko, Kenzo; Watanabe, Yoshihiko; Kondo, Takeshi

    1985-01-01

    To evaluate whole body distribution and kinetics of Thallium-201 at exercise and redistribution, whole body scintigraphy (WB-S) was performed on 12 normal subjects (N), 19 patients with angina pectoris (AP) and 18 patients with old myocardial infarction (MI). WB-S was obtained using a gamma camera OMEGA 500 and analized by ADAC System IV. We estimated the following parameters from WB-S; 1) %Distribution (%D): the ratio of whole body counts to organ counts 2) washout rate (WR) in each organ. %D of the heart in N, AP and MI was similar at rest and exercise. At exercise, %D of the lung and the liver decreased and %D of thighs increased remarkably than at rest. At supine exercise, the lung indicated high %D and thinghs indicated low %D compared with at upright exercise. WR of the heart in AP and MI was significantly lower than in N (p<0.005, p<0.01) and further decreased proportionally to the number of stenotic coronary arteries and related to the ischemic ST depression of exercise ECG. WR of the heart was not correlation with pressure rate product and this finding suggested that WR of the heart was not prescribed by the tolerance of exercise but related to coronary flow at exercise a certain degree. WR of the lung in MI was significantly higher (p<0.025) and WR of thighs in AP and MI was significantly lower (p<0.025, p<0.05) compared with N. (author)

  4. Comparison of whole-body vibration exercise and plyometric exercise to improve isokinetic muscular strength, jumping performance and balance of female volleyball players.

    Science.gov (United States)

    Kim, Yong-Youn; Park, Si-Eun

    2016-11-01

    [Purpose] The purpose of this study was to assess the effect of whole-body vibration exercise and plyometric exercise on female volleyball players. [Subjects and Methods] Subjects were randomly allocated to two exercise groups (whole-body vibration exercise group and plyometric exercise group). The exercise was conducted three times each week for 8 weeks. Isokinetic muscular strength, jumping performance, and balance were measured before starting the exercise and after finishing the 8 weeks of exercise. [Results] Measurements of isokinetic muscular strength revealed that the whole-body vibration exercise group showed significant increase after the exercise. However, the plyometric exercise group had no significant increase in lumbar flexion, extension, and knee flexion. Measurements of vertical jumping revealed that, the whole-body vibration exercise group had no significant increase after the exercise. However, the plyometric exercise group showed significant increase. Measurements of balance revealed that, the whole-body vibration exercise group showed significant increase. However, the plyometric exercise group showed no significant increase. [Conclusion] Although both whole-body vibration and plyometric exercises are effective intervention methods, the two methods have different effects on the improvement of isokinetic muscular strength, jumping performance, and balance of female volleyball players.

  5. Factors affecting gastric uptake in whole body FDG-PET imaging

    International Nuclear Information System (INIS)

    Tomemori, Takashi; Kitagawa, Mami; Nakahara, Tadaki; Wu, Jin; Nakagawa, Keiichi; Uno, Kimiichi; Abe, Kinji; Tomiyoshi, Katsumi

    2001-01-01

    Positron emission tomography (PET) using 2-deoxy-2-[ 18 F]-fluoro-D-glucose (FDG) is very useful for the detection and staging of tumors. However, FDG is also accumulated in the normal tissues in various degrees. This physiological FDG uptake is often seen in intestine, making confusion with malignant tumor. The aim of this study was to identify factors influencing physiological FDG uptake in the stomach. A total of 136 people who underwent cancer screening or staging of tumors except for gastric cancer using FDG whole-body PET was examined (mean age: 55.6 yrs). All subjects fasted for at least 4 hours before the PET study and were administrated with FDG intravenously (mean FDG dose: 308.9 MBq). Emission images were acquired on a whole-body PET scanner and images were reconstructed without attenuation correction. The intensity of gastric uptake of FDG whole-body PET image was visually classified into 3 grades; grade 2 = the intensity of gastric uptake more than pulmonary uptake, grade 1 = the intensity of gastric uptake equal to or less than pulmonary uptake, grade 0 = no contrast between gastric uptake and background. Twenty-eight subjects (20.6%) were classified into grade 2, 42 subjects (30.9%) were grade 1 and 66 subjects (48.5%) were grade 0. Subjects' age, fasting time, FDG dose, serum glucose level, free fatty acid level and insulin level were not significantly correlated with the intensity of gastric uptake. But the subjects with higher gastric uptake tended to have anti-Helicobactor pylori (H. pylori) antibodies. The rate of having anti-H.pylori antibodies in the grade 2 group is significantly higher than the grade 1 group (85.7% vs. 72.5%, p<0.05), and that of the grade 1 group is significantly higher than the grade 0 group (72.5% vs. 42.2%, p<0.01). Gastric uptake was observed in about half of subjects. Especially, approximately 20% of all showed high gastric uptake, which was associated with H.pylori infection. Therefore, most of the subjects with high

  6. Factors affecting gastric uptake in whole body FDG-PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tomemori, Takashi; Kitagawa, Mami; Nakahara, Tadaki; Wu, Jin; Nakagawa, Keiichi; Uno, Kimiichi; Abe, Kinji; Tomiyoshi, Katsumi [Nishidai Clinic Diagnostic Imaging Center, Tokyo (Japan)

    2001-06-01

    Positron emission tomography (PET) using 2-deoxy-2-[{sup 18}F]-fluoro-D-glucose (FDG) is very useful for the detection and staging of tumors. However, FDG is also accumulated in the normal tissues in various degrees. This physiological FDG uptake is often seen in intestine, making confusion with malignant tumor. The aim of this study was to identify factors influencing physiological FDG uptake in the stomach. A total of 136 people who underwent cancer screening or staging of tumors except for gastric cancer using FDG whole-body PET was examined (mean age: 55.6 yrs). All subjects fasted for at least 4 hours before the PET study and were administrated with FDG intravenously (mean FDG dose: 308.9 MBq). Emission images were acquired on a whole-body PET scanner and images were reconstructed without attenuation correction. The intensity of gastric uptake of FDG whole-body PET image was visually classified into 3 grades; grade 2 = the intensity of gastric uptake more than pulmonary uptake, grade 1 = the intensity of gastric uptake equal to or less than pulmonary uptake, grade 0 = no contrast between gastric uptake and background. Twenty-eight subjects (20.6%) were classified into grade 2, 42 subjects (30.9%) were grade 1 and 66 subjects (48.5%) were grade 0. Subjects' age, fasting time, FDG dose, serum glucose level, free fatty acid level and insulin level were not significantly correlated with the intensity of gastric uptake. But the subjects with higher gastric uptake tended to have anti-Helicobactor pylori (H. pylori) antibodies. The rate of having anti-H.pylori antibodies in the grade 2 group is significantly higher than the grade 1 group (85.7% vs. 72.5%, p<0.05), and that of the grade 1 group is significantly higher than the grade 0 group (72.5% vs. 42.2%, p<0.01). Gastric uptake was observed in about half of subjects. Especially, approximately 20% of all showed high gastric uptake, which was associated with H.pylori infection. Therefore, most of the subjects

  7. Whole-body kinetics and dosimetry of cis-4-[18F]fluoro-l-proline

    International Nuclear Information System (INIS)

    Boerner, Anne R.; Langen, Karl-J.; Herzog, Hans; Hamacher, Kurt; Mueller-Mattheis, Volker; Schmitz, Thomas; Ackermann, Rolf; Coenen, Heinz H.

    2001-01-01

    The whole-body distribution of 4-cis[ 18 F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 μGy/MBq). The effective dose according to ICRP 60 was 15.1 μSv/MBq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro

  8. Whole-body kinetics and dosimetry of cis-4-[(18)F]fluoro-L-proline.

    Science.gov (United States)

    Börner, A R; Langen, K J; Herzog, H; Hamacher, K; Müller-Mattheis, V; Schmitz, T; Ackermann, R; Coenen, H H

    2001-04-01

    The whole-body distribution of 4-cis[(18)F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 microGy/mbq). The effective dose according to ICRP 60 was 15.1 microSv/mbq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro.

  9. Whole-body magnetic resonance angiography of patients using a standard clinical scanner

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Tomas; Wikstroem, Johan; Eriksson, Mats-Ola; Lundberg, Anders; Ahlstroem, Haakan [Uppsala University Hospital, Department of Diagnostic Radiology, Uppsala (Sweden); Johansson, Lars [Uppsala University Hospital, Uppsala (Sweden); Ljungman, Christer [Uppsala University Hospital, Department of Vascular Surgery, Uppsala (Sweden); Hoogeven, Romhild [Philips Medical Systems, MR Clinical Science, Best (Netherlands)

    2006-01-01

    The purpose of this study was to evaluate the technique of whole-body magnetic resonance angiography (MRA) of patients with a standard clinical scanner. Thirty-three patients referred for stenoses, occlusions, aneurysms, assessment of patency of vascular grafts, vasculitis and vascular aplasia were examined in a 1.5-T scanner using its standard body coil. Three-dimensional sequences were acquired in four stations after administration of one intravenous injection of 40 ml conventional gadolinium contrast agent. Different vessel segments were evaluated as either diagnostic or nondiagnostic and regarding the presence of stenoses with more than 50% diameter reduction, occlusions or aneurysms. Of 923 vessel segments, 67 were not evaluable because of poor contrast filling (n=31), motion artefacts (n=20), venous overlap (n=12) and other reasons (n=4). Stenoses of more than 50%, occlusions or aneurysms were observed in 26 patients (129 segments). In nine patients additional unsuspected pathology was found. In 10 out of 14 patients (71/79 segments) there was conformity between MRA and digital subtraction angiography regarding the grade of stenosis. This study shows that whole-body MRA with a standard clinical scanner is feasible. Motion artefacts and the timing of the contrast agent through the different segments are still problems to be solved. (orig.)

  10. Lightweight Vehicle and Driver’s Whole-Body Models for Vibration Analysis

    Science.gov (United States)

    MdSah, Jamali; Taha, Zahari; Azwan Ismail, Khairul

    2018-03-01

    Vehicle vibration is a main factor for driving fatigue, discomfort and health problems. The ability to simulate the vibration characteristics in the vehicle and its effects on driver’s whole-body vibration will give significant advantages to designers especially on the vehicle development time and cost. However, it is difficult to achieve optimal condition of ride comfort and handling when using passive suspension system. This paper presents mathematical equations that can be used to describe the vibration characteristics of a lightweight electric vehicle that had been developed. The vehicle’s model was combined with the lumped-parameter model of driver to determine the whole-body vibration level when the vehicle is passing over a road hump using Matlab Simulink. The models were simulated at a constant speed and the results were compared with the experimental data. The simulated vibration level at the vehicle floor and seat were almost similar to the experimental vibration results. The suspension systems that are being used for the solar vehicle are able to reduce the vibration level due to the road hump. The models can be used to simulate and choose the optimal parameters for the suspensions.

  11. Plutonium fecal and urinary excretion functions: Derivation from a systematic whole-body retention function

    International Nuclear Information System (INIS)

    Sun, C.; Lee, D.

    1999-01-01

    Liver-bile secretion directly influences the content of plutonium in feces. To assess the reliability of plutonium metabolic models and to improve the accuracy of interpreting plutonium fecal data, the authors developed a compartmental model that simulates the metabolism of plutonium in humans. With this model, they can describe the transport of plutonium contaminants in the systemic organs and tissues of the body, including fecal and urine excretions, without using elaborate kinetic information. The parameter values of the models, which describe the translocation rates and recycling of plutonium in the body, can be derived from a multi-term exponential systemic function for whole-body retention. The analytical derivations and algorithms for solving translocation parameter values are established for the model and illustrated by applying them to the biokinetics and bioassay of plutonium. This study describes how to (1) design a physiological model for incorporating liver biliary secretion and for obtaining a fecal-excretion function, (2) develop an analytical solution for identifying the translocation-parameter values incorporating the recycling of plutonium in the body, and (3) derive a set of urinary and fecal excretion-functions from a published systemic whole-body retention function, generally acknowledged to be accurate, as a real and practical example

  12. Long-term effect of whole-body X-irradiation on cell-mediated immune reaction in mice

    International Nuclear Information System (INIS)

    Norimura, Toshiyuki; Tsuchiya, Takehiko

    1989-01-01

    Age-related change in immunological activity was examined at 10 to 91 weeks following whole-body irradiation by determining the specific anti-tumor cell-mediated immunity in host mice induced and/or enhanced by local irradiation to transplanted tumor. Median survival time of the non-irradiated C3H/He female mice was 98.6 weeks while the median life-span of the mice exposed to two and four Gy of 250 kVp X-rays at the age of 10-12 weeks was shortened by 14.9 and 23.4 weeks, respectively. The rate of tumor reduction within two weeks after local irradiation to tumor and the growth inhibitory activitiy of spleen cells from tumor irradiated mice were reduced in a dose-dependent manner when assessed 10 weeks after whole-body irradiation, but recovered to the near-complete level of the non-irradiated controls within a few months, then gradually decreased with normal aging. These results suggest that the age-dependent decline of this immunological activity apears earlier in the irradiated mice as a result of whole-body X-irradiation at a young age, suggesting accelerated aging of the immune system. (author)

  13. Whole-body magnetic resonance angiography for presurgical planning of free-flap head and neck reconstruction

    International Nuclear Information System (INIS)

    Kramer, Manuel; Nkenke, Emeka; Kikuchi, Keiichi; Schwab, Siegfried A.; Janka, Rolf; Uder, Michael; Lell, Michael

    2012-01-01

    Objectives: Aim of the study was to evaluate if a whole-body magnetic resonance angiography (MRA) protocol meets the requirements to evaluate the donor and host site target vessels for planning of microvascular head and neck reconstructions. Patients and methods: In 20 patients, scheduled for reconstruction of the mandible with fibular free flaps, contrast-enhanced whole-body MRA was performed prior to surgery. 32-Channel 1.5-T MR angiograms were acquired using a 2-step contrast (gadobutrol) injection scheme to visualize the arterial vasculature from head to feet. Maximum intensity projection and multiplanar reconstruction technique was employed to visualize MRA data. For image evaluation the arterial tree was divided into 51 segments. The presence of artefacts impairing diagnostic quality was noted. Evaluable segments were assessed regarding the presence of stenoses >50% diameter reduction, occlusions or aneurysms. Results: No adverse reactions or complications occurred. Of 1020 vessel segments 1003 (98.3%) were evaluable. 36 stenoses >50%, 50 occlusions and one aneurysm were observed. In 21 of 40 lower limbs relevant atherosclerotic changes were depicted. Conclusion: Whole-body MRA proved to be a suitable three-dimensional, noninvasive, nonionising modality for preoperative evaluation of the entire arterial vasculature.

  14. Protective Role Of Fresh Pomegranate Against Oxidative Damage In Whole Body Gamma Irradiated Male Albino Rats

    International Nuclear Information System (INIS)

    Kassab, F.M.A.; Taha, M.S.

    2013-01-01

    Twenty four male albino rats, body weight 100-130 g, were used to evaluate the protective role of fresh pomegranate fruit intake for 30 days on the damage induced by single dose of 6 Gy whole body gamma irradiation. The rats were randomly and equally divided into four groups: group (1): control, group (2): irradiated with 6 Gy, group (3): pomegranate for 30 days and group (4): pomegranate for 30 days followed by 6 Gy whole body irradiation. At the end of the experiment, all rats were sacrificed after 12 hours fasting then sera were separated for the determination of sugar, total antioxidant, lipid profile and liver and kidney functions. Results showed that gamma radiation caused significant decline (P<0.05) in serum total antioxidant, total protein, albumin, HDL-C and blood glucose with significant elevation (P<0.05) in other hepato-renal markers in addition to serum total cholesterol, triglycerides and LDL-C. These changes were significantly attenuated in irradiated animals pre-treated with whole fresh pomegranate fruit leading to the conclusion that pre-intake of pomegranate fruit had a radio- protective effect. This protection of this whole fruit may be due to the increased total antioxidant level leading to free radical scavenging

  15. Vibration energy absorption in the whole-body system of a tractor operator

    Directory of Open Access Journals (Sweden)

    Jan Szczepaniak

    2014-06-01

    Full Text Available Many people are exposed to whole-body vibration (WBV in their occupational lives, especially drivers of vehicles such as tractor and trucks. The main categories of effects from WBV are perception degraded comfort interference with activities-impaired health and occurrence of motion sickness. Absorbed power is defined as the power dissipated in a mechanical system as a result of an applied force. The vibration-induced injuries or disorders in a substructure of the human system are primarily associated with the vibration power absorption distributed in that substructure. The vibration power absorbed by the exposed body is a measure that combines both the vibration hazard and the biodynamic response of the body. The article presents measurement method for determining vibration power dissipated in the human whole body system called Vibration Energy Absorption (VEA. The vibration power is calculated from the real part of the force-velocity cross-spectrum. The absorbed power in the frequency domain can be obtained from the cross-spectrum of the force and velocity. In the context of the vibration energy transferred to a seated human body, the real component reflects the energy dissipated in the biological structure per unit of time, whereas the imaginary component reflects the energy stored/released by the system. The seated human is modeled as a series/parallel 4-DOF dynamic models. After introduction of the excitation, the response in particular segments of the model can be analyzed. As an example, the vibration power dissipated in an operator has been determined as a function of the agricultural combination operating speed 1.39 – 4.16 ms[sup] -1 [/sup].

  16. Whole-Body Vibration Training Improves Heart Rate Variability and Body Fat Percentage in Obese Hispanic Postmenopausal Women.

    Science.gov (United States)

    Severino, Gregory; Sanchez-Gonzalez, Marcos; Walters-Edwards, Michelle; Nordvall, Michael; Chernykh, Oksana; Adames, Jason; Wong, Alexei

    2017-07-01

    The present study examined the effects of a 6-week whole-body vibration training (WBVT) regimen on heart rate variability (HRV) and body composition in obese Hispanic postmenopausal women. Participants were randomly assigned to either WBVT (n = 13) or a nonexercising control group (n = 14). HRV and body composition were measured before and after 6 weeks. There was a significant group by time interaction (P < .05) for heart rate, sympathovagal balance, and body fat percentage (BF%) such that all significantly decreased (P < .05); and R-R intervals significantly increased (P < .05) following WBVT compared to no changes after control. The changes in sympathovagal balance were correlated with changes in BF% (r = .63, P < .05). Our findings indicate that WBVT improves HRV and BF% in obese Hispanic postmenopausal women. The improvement in BF% partially explained the decrease in sympathovagal balance. Since obese and older individuals are at increased risk of developing cardiovascular diseases, they could potentially benefit from WBVT.

  17. Patient-Specific Biomechanical Model as Whole-Body CT Image Registration Tool

    OpenAIRE

    Li, Mao; Miller, Karol; Joldes, Grand Roman; Doyle, Barry; Garlapati, Revanth Reddy; Kikinis, Ron; Wittek, Adam

    2015-01-01

    Whole-body computed tomography (CT) image registration is important for cancer diagnosis, therapy planning and treatment. Such registration requires accounting for large differences between source and target images caused by deformations of soft organs/tissues and articulated motion of skeletal structures. The registration algorithms relying solely on image processing methods exhibit deficiencies in accounting for such deformations and motion. We propose to predict the deformations and moveme...

  18. Command Recognition of Robot with Low Dimension Whole-Body Haptic Sensor

    Science.gov (United States)

    Ito, Tatsuya; Tsuji, Toshiaki

    The authors have developed “haptic armor”, a whole-body haptic sensor that has an ability to estimate contact position. Although it is developed for safety assurance of robots in human environment, it can also be used as an interface. This paper proposes a command recognition method based on finger trace information. This paper also discusses some technical issues for improving recognition accuracy of this system.

  19. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  20. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)