  1. X-ray imaging system

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    A novel, high-speed apparatus for use in X-ray computerised tomography is described in detail. It consists of a semi-circular array of X-ray sources, collimators and an ion chamber array for detection of the X-rays. The X-ray sources may be pulsed in salvos such that the corresponding detectors in the array are only illuminated by one source. The use of computer controlled salvos speeds up the image processing by at least a factor of two. The ion chamber array is designed to have a constant detection efficiency for varying angles of X-ray incidence. A detailed description of the detector construction and suggested gaseous fillings are given. It is claimed that the present tomographic system allows fast and accurate imaging of internal body organs and is insensitive to the blurring effects which motion of these organs tends to produce. (UK)

  2. X-ray system analysis

    International Nuclear Information System (INIS)

    Shapiro, J.S.

    1985-01-01

    An X-ray system tester for measuring anode voltage, cathode voltage, anode current, filament current and line voltage in an X-ray system has a selector which couples one of these analog signals or one of a plurality of processing control signals entered by an operator from a control panel to a digitizing section selectively in accordance with control signals provided to the selector by a computing section. The digitizing section converts the selected signal into a train of pulses having a frequency proportional to the value of the selected signal. These pulses are counted, the counts being used by the computing section to determine the value of the selected signal. This computed value is stored in a computing memory section of the computing section. The computing section is adapted to store a plurality of the sets of signals produced during a corresponding sequence of operational intervals of the X-ray system and determines a measure of the deviation of any selected one of the stored electrical signals over the sequence of operating intervals. Each signal produced during the sequential operational intervals can be recalled to aid analysis of the operation of the X-ray system. (author)

  3. Illumination system for X-ray lithography

    International Nuclear Information System (INIS)

    Buckley, W.D.

    1989-01-01

    An X-ray lithography system is described, comprising: a point source of X-Ray radiation; a wafer plane disposed in spaced relation to the point source of X-Ray radiation; a mask disposed between the point source of X-Ray radiation and the wafer plane whereby X-Ray radiation from the point source of X-ray radiation passes through the mask to the water plane; and X-Ray absorbent means mounted between the point source of X-Ray radiation and the wafer plane, the X-Ray absorbent means being of quadratically absorption from maximum absorption at the center to minimum absorption at the edge so as to have a radial absorption gradient profile to compensate for radial flux variation of the X-Ray radiation

  4. An overview on the research of Sr2IrO4-based system probed by X-ray absorption spectroscopy

    Science.gov (United States)

    Cheng, Jie; Zhu, Chaomin; Ma, Jingyuan; Wang, Yu; Liu, Shengli

    2018-03-01

    Investigations of materials with 5d transition metal ions have opened up new paradigms in condensed-matter physics because of their large spin-orbit coupling (SOC) interactions. The typical compound is Sr2IrO4, which attracted much attention due to its similarities to the parent compound of high-Tc cuprate superconductor La2CuO4. Theoretical calculations predicted that the unconventional superconductivity can occur in carrier doped-Sr2IrO4 system. Until now, hundreds of experimental methods were devoted to investigate the carrier doping effect on Sr2IrO4. Synchrotron radiation-based X-ray absorption spectroscopy (XAS) made great contributions to the local lattice and electronic structure, and also the intimate relationship between the local structure and physical properties induced by carrier doping. The aim of this review is a short introduction to the progress of research on Sr2IrO4-based system probed by the unique technique — XAS, including the strength of the SOC, valence changes upon doping and even local lattice structure with atomic level for this Sr2IrO4-based family.

  5. Mobile X-ray radiographic systems

    International Nuclear Information System (INIS)

    Buchmann, F.

    1990-01-01

    Mobile X-ray radiography equipment consists of the X-ray source with the generator and the switching and control devices, mounted on a mobile unit for transport to the patient to be examined. These mobile systems, just as the stationary equipment, have been profiting from the technological progress made in the area of X-ray generation, and the considerable improvements thus achieved have altered not only the value of these systems, but also their applicability which frequently comes near that of stationary equipment. (orig./GDG) [de

  6. Study on an x-ray microcalorimeter using Ir superconductor

    International Nuclear Information System (INIS)

    Kunieda, Yuichi; Zen, Nobuyuki; Nakazawa, Masaharu; Takahashi, Hiroyuki; Fukuda, Daiji; Ohkubo, Masataka

    2005-01-01

    We fabricated a ten-pixel Ir/Au-transition edge sensor (TES) microcalorimeter, and investigated its signal and noise-property. The device was successfully operated in electro-thermal feedback (ETF) mode. More than six position groups could be discrete by using pulse height and rise time parameters of observed x-ray signals. It seems that the separation groups reflect the pixel position of the TES. The best energy resolution was 18.8 eV (FWHM) for 5.9 keV. The noise spectrum showed that noise level of ten-pixel was larger than that of single pixel. A unexplained peak was observed in the plot of current noise for each bias point. (author)

  7. Multilayer X-ray imaging systems

    Science.gov (United States)

    Shealy, D. L.; Hoover, R. B.; Gabardi, D. R.

    1986-01-01

    An assessment of the imaging properties of multilayer X-ray imaging systems with spherical surfaces has been made. A ray trace analysis was performed to investigate the effects of using spherical substrates (rather than the conventional paraboloidal/hyperboloidal contours) for doubly reflecting Cassegrain telescopes. These investigations were carried out for mirrors designed to operate at selected soft X-ray/XUV wavelengths that are of significance for studies of the solar corona/transition region from the Stanford/MSFC Rocket X-Ray Telescope. The effects of changes in separation of the primary and secondary elements were also investigated. These theoretical results are presented as well as the results of ray trace studies to establish the resolution and vignetting effects as a function of field angle and system parameters.

  8. X-ray image subtracting system

    International Nuclear Information System (INIS)

    Wesbey, W.H.; Keyes, G.S.; Georges, J.-P.J.

    1982-01-01

    An X-ray image subtracting system for making low contrast structures in the images more conspicuous is described. An X-ray source projects successive high and low energy X-ray beam pulses through a body and the resultant X-ray images are converted to optical images. Two image pick-up devices such as TV cameras that have synchronously operated shutters receive the alternate images and convert them to corresponding analog video signals. In some embodiments, the analog signals are converted to a matrix of digital pixel signals that are variously processed and subtracted and converted to signals for driving a TV monitor display and analog storage devices. In other embodiments the signals are processed and subtracted in analog form for display. The high and low energy pulses can follow each other immediately so good registration between subtracted images is obtainable even though the anatomy is in motion. The energy levels of the X-ray pulses are chosen to maximize the difference in attenuation between the anatomical structure which is to be subtracted out and that which remains. (author)

  9. Visible/IR light and x-rays in femtosecond synchronism from an x-ray free-electron laser

    International Nuclear Information System (INIS)

    Adams, B. A.; Experimental Facilities Division

    2005-01-01

    A way is proposed to obtain pulses of visible/infrared light in femtosecond synchronism with x-rays from an x-ray free-electron laser (XFEL), using the recently proposed emittance-slicing technique. In an XFEL undulator, only the short section of an electron bunch whose emittance is left unchanged by the slicing will emit intense coherent x-rays in the XFEL undulator. At the same time, the bunch emits highly collimated transition undulator radiation (TUR) into a cone whose opening angle is the reciprocal relativisticity parameter gamma. Due to the variation of the transverse momentum induced by the emittance slicing, the effective number of charges contributing to the TUR varies along the bunch, and is higher in the sliced-out part that emits the coherent x-rays. As with coherent synchrotron radiation (CSR), the TUR is thus coherently enhanced (CTUR) at near-infrared wavelengths. Coming from the same part of the bunch the CTUR and the coherent x-rays are perfectly synchronized to each other. Because both types of radiation are generated in the long straight XFEL undulator, there are no dispersion effects that might induce a timing jitter. With typical XFEL parameters, the energy content of the single optical cycle of near-IR CTUR light is about 100 Nano-Joule, which is quite sufficient for most pump-probe experiments

  10. Electron-ion-x-ray spectrometer system

    International Nuclear Information System (INIS)

    Southworth, S.H.; Deslattes, R.D.; MacDonald, M.A.

    1993-01-01

    The authors describe a spectrometer system developed for electron, ion, and x-ray spectroscopy of gas-phase atoms and molecules following inner-shell excitation by tunable synchrotron radiation. The spectrometer has been used on beamline X-24A at the National Synchrotron Light Source for excitation-dependent studies of Ar L-shell and K-shell photoexcitation and vacancy decay processes. The instrumentation and experimental methods are discussed, and examples are given of electron spectra and coincidence spectra between electrons and fluorescent x-rays

  11. Diffracted X-ray tracking: new system for single molecular detection with X-rays

    CERN Document Server

    Sasaki, Y C; Adachi, S; Suzuki, Y; Yagi, N

    2001-01-01

    We propose a new X-ray methodology for direct observations of the behaviors of single molecular units in real time and real space. This new system, which we call Diffracted X-ray Tracking (DXT), monitors the Brownian motions of a single molecular unit by observations of X-ray diffracted spots from a nanocrystal, tightly bound to the individual single molecular unit in bio-systems. DXT does not determine any translational movements, but only orientational movements.

  12. Diffracted X-ray tracking: new system for single molecular detection with X-rays

    International Nuclear Information System (INIS)

    Sasaki, Y.C.; Okumura, Y.; Adachi, S.; Suzuki, Y.; Yagi, N.

    2001-01-01

    We propose a new X-ray methodology for direct observations of the behaviors of single molecular units in real time and real space. This new system, which we call Diffracted X-ray Tracking (DXT), monitors the Brownian motions of a single molecular unit by observations of X-ray diffracted spots from a nanocrystal, tightly bound to the individual single molecular unit in bio-systems. DXT does not determine any translational movements, but only orientational movements

  13. Development of X-ray microcalorimeter using Ir/Au-TES

    International Nuclear Information System (INIS)

    Kunieda, Yuichi; Ohno, Masashi; Nakazawa, Masaharu; Takahashi, Hiroyuki; Fukuda, Daiji; Ohkubo, Masataka; Hirayama, Huminori; Ataka, Manabu

    2004-01-01

    We are developing x-ray mirocalorimeters using transition edge sensors of iridium/gold (Ir/Au-TES) for high resolution x-ray spectroscopy. TES microcalorimeters can achieve faster response than conventional microcalorimeters by keeping the operating point of TES in the transition region through the use of strong negative electrothermal feedback (ETF). At present, the energy resolution of 9.4 eV (FWHM) was achieved for a 5899 eV Mn K al line. At a synchrotron X-ray radiation facility, we demonstrated microscopic signal response profile of the device and high-resolution X-ray fluorescence spectroscopy using a small amount of sample. (author)

  14. Temperature Profile of IR Blocking Windows Used in Cryogenic X-Ray Spectrometers

    International Nuclear Information System (INIS)

    Friedrich, S.; Funk, T.; Drury, O.; Labov, S.E.

    2000-01-01

    Cryogenic high-resolution X-ray spectrometers are typically operated with thin IR blocking windows to reduce radiative heating of the detector while allowing good x-ray transmission. We have estimated the temperature profile of these IR blocking windows under typical operating conditions. We show that the temperature in the center of the window is raised due to radiation from the higher temperature stages. This can increase the infrared photon flux onto the detector, thereby increasing the IR noise and decreasing the cryostat hold time. The increased window temperature constrains the maximum window size and the number of windows required. We discuss the consequences for IR blocking window design

  15. 21 CFR 892.1720 - Mobile x-ray system.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1720 Mobile x-ray system. (a) Identification. A mobile x-ray system is a transportable device system intended to be used to generate and control x-ray... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mobile x-ray system. 892.1720 Section 892.1720...

  16. Resonant x-ray scattering in correlated systems

    CERN Document Server

    Ishihara, Sumio

    2017-01-01

    The research and its outcomes presented here is devoted to the use of x-ray scattering to study correlated electron systems and magnetism. Different x-ray based methods are provided to analyze three dimensional electron systems and the structure of transition-metal oxides. Finally the observation of multipole orderings with x-ray diffraction is shown.

  17. Resonant X-ray scattering in correlated systems

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Youichi [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan). Inst. of Materials Structure Science; Ishihara, Sumio (ed.) [Tohoku Univ., Sendai, Miyagi (Japan). Dept. of Physics

    2017-03-01

    The research and its outcomes presented here is devoted to the use of X-ray scattering to study correlated electron systems and magnetism. Different X-ray based methods are provided to analyze three dimensional electron systems and the structure of transition-metal oxides. Finally the observation of multipole orderings with X-ray diffraction is shown.

  18. Differences of X-ray exposure between X-ray diagnostics with a conventional X-ray screen-system and with an image-intensifier-television-unit

    International Nuclear Information System (INIS)

    Loehr, H.; Vogel, H.; Reinhart, J.; Jantzen, R.

    1977-01-01

    During X-ray diagnostics of patients in the II. Medizinische Poliklinik the X-ray exposure was determined. It corresponded to the data described in literature. Two groups were compared: 518 patients examined with a conventional X-ray screen-system and 642 patients examined with an image-intensifier-television-system. The results demonstrated that with exception of thoracical X-ray examination the replacing of the old system by the television system brought a remarkable increase of the X-ray exposure. The doses depended of the patients constitution to a high degree. (orig.) [de

  19. The selection criteria elements of X-ray optics system

    Science.gov (United States)

    Plotnikova, I. V.; Chicherina, N. V.; Bays, S. S.; Bildanov, R. G.; Stary, O.

    2018-01-01

    At the design of new modifications of x-ray tomography there are difficulties in the right choice of elements of X-ray optical system. Now this problem is solved by practical consideration, selection of values of the corresponding parameters - tension on an x-ray tube taking into account the thickness and type of the studied material. For reduction of time and labor input of design it is necessary to create the criteria of the choice, to determine key parameters and characteristics of elements. In the article two main elements of X-ray optical system - an x-ray tube and the detector of x-ray radiation - are considered. Criteria of the choice of elements, their key characteristics, the main dependences of parameters, quality indicators and also recommendations according to the choice of elements of x-ray systems are received.

  20. High-z X-ray Obscured Quasars in Galaxies with Extreme Mid-IR/Optical Colors

    Science.gov (United States)

    Piconcelli, E.; Lanzuisi, G.; Fiore, F.; Feruglio, C.; Vignali, C.; Salvato, M.; Grappioni, C.

    2009-05-01

    Extreme Optical/Mid-IR color cuts have been used to uncover a population of dust-enshrouded, mid-IR luminous galaxies at high redshifts. Several lines of evidence point towards the presence of an heavily absorbed, possibly Compton-thick quasar at the heart of these systems. Nonetheless, the X-ray spectral properties of these intriguing sources still remain largely unexplored. Here we present an X-ray spectroscopic study of a large sample of 44 extreme dust-obscured galaxies (EDOGs) with F24 μm/FR>2000 and F24 μm>1.3 mJy selected from a 6 deg2 region in the SWIRE fields. The application of our selection criteria to a wide area survey has been capable of unveiling a population of X-ray luminous, absorbed z>1 quasars which is mostly missed in the traditional optical/X-ray surveys performed so far. Advances in the understanding of the X-ray properties of these recently-discovered sources by Simbol-X observations will be also discussed.

  1. Two digital X-ray imaging systems for applications in X-ray diffraction

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Flesher, A.C.; Bryant, C.J.; Lincoln, A.D.; Tucker, P.A.; Swanton, S.W.

    1986-08-01

    Two digital X-ray imaging systems developed at the Rutherford Appleton Laboratory are described:- the Mark I and the Mark II. Both use a bidimensionally sensitive Multiwire proportional counter as the basic X-ray image transducer coupled to a digital microcomputer system. The Mark I system provides the advantages of high speed, high sensitivity digital imaging directly into the computer with the potential for software control of the sample orientation and environment. The Mark II system adds the novel features of signal averaging and multi-frame exposures. (author)

  2. Development of real-time x-ray microtomography system

    International Nuclear Information System (INIS)

    Takano, H; Morikawa, M; Konishi, S; Azuma, H; Shimomura, S; Tsusaka, Y; Kagoshima, Y; Nakano, S; Kosaka, N; Yamamoto, K

    2013-01-01

    We have developed a four-dimensional (4D) x-ray microcomputed tomography (CT) system that can obtain time-lapse CT volumes in real time. The system consists of a high-speed sample rotation system and a high-frame-rate x-ray imager, which are installed at a synchrotron radiation x-ray beamline. As a result of system optimization and introduction of a 'zoom resolution' procedure, a real-time 4D CT movie with a frame rate of 30 was obtained with a voxel size of 2.5 μm using 10 keV x-rays

  3. Material Discriminated X-Ray CT System by Using New X-Ray Imager with Energy Discriminate Function

    Directory of Open Access Journals (Sweden)

    Toru Aoki

    2008-04-01

    Full Text Available Material discriminated X-ray CT system has been constructed by using conventional X-ray tube (white X-ray source and photon-counting X-ray imager as an application with energy band detection. We have already reported material identify X-ray CT using K-shell edge method elsewhere. In this report the principle of material discrimination was adapted the separation of electron-density and atomic number from attenuation coefficient mapping in X-ray CT reconstructed image in two wavelength X-ray CT method using white X-ray source and energy discriminated X-ray imager by using two monochrome X-ray source method. The measurement phantom was prepared as four kinds material rods (Carbon(C, Iron(Fe, Copper(Cu, Titanium(Ti rods of 3mm-diameter inside an aluminum(Al rod of 20mm-diameter. We could observed material discriminated X-ray CT reconstructed image, however, the discrimination properties were not good than two monochrome X-ray CT method. This results was could be explained because X-ray scattering, beam-hardening and so on based on white X-ray source, which could not observe in two monochrome X-ray CT method. However, since our developed CdTe imager can be detect five energy-bands at the same time, we can use multi-band analysis to decrease the least square error margin. We will be able to obtain more high separation in atomic number mapping in X-ray CT reconstructed image by using this system.

  4. Tissue doses in X-ray examinations of osteoarticular system

    International Nuclear Information System (INIS)

    Rabkin, I.Kh.; Stavitskij, R.V.; Blinov, N.N.; Vasil'ev, Yu.D.

    1985-01-01

    The X-ray method in diagnosis of the osteoarticular system disease is described. Problems on tissue dose distribution in X-ray examinations of a skeleton, a skull, humeral articulation, cervical, thoracic and lumbar vertebrae, hip joint, hipbones are considered. The values of specific tissue doses in roentgenography of the osteoarticular system are given

  5. 21 CFR 1020.40 - Cabinet x-ray systems.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cabinet x-ray systems. 1020.40 Section 1020.40 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... are all x-ray systems designed primarily for the inspection of carry-on baggage at airline, railroad...

  6. FT-IR and X-ray spectroscopic investigations of Na-diclofenac-cyclodextrins interactions

    Science.gov (United States)

    Bratu, I.; Astilean, S.; Ionesc, Corina; Indrea, E.; Huvenne, J. P.; Legrand, P.

    1998-01-01

    The association of DCF-Na (the salt of the 2-[(2,6-dichlorophenyl)amino]-phenyl-acetic acid) with β-CD (cyclodextrin) in some therapeutic formulas can contribute to the optimisation of the physico-chemical and pharmaceutical properties of the parent drug. The understanding of the interaction between DCF with β-CD represents the objective of this study. FT-IR spectroscopy is one of the methods which clarify the nature of these interactions in complexes of such type. Therefore the changes in FT-IR spectra of binary dispersed systems DCF/ β-CD in physical mixture and coprecipitate from methanol (molar ratios: 1/1, 1/2, 2/3, 3/4, 7/4) were analysed. The analysis of the broadening of the X-ray powder diffraction line has been applied to investigate the average effective crystallite size, the mean square of the microstrain caused by distortions within β-CD crystallite and the fault probability in the binary dispersed DCF/ β-CD coprecipitate system.

  7. Study on TV X-ray system characteristics

    International Nuclear Information System (INIS)

    Semenov, A.P.; Volkov, A.V.

    1978-01-01

    The results are presented of comparative investigations into the main characteristics of TV X-ray systems (TXS) and X-ray radiography when X-raying of the 1Kh18N9T steel. The following characteristics are considered: the threshold contrast sensitivity, the sensitivity to revealing standard defects, and the dose rate of X-radiation at the input of the X-ray converter. Practical recommendations are given on the use of TXS in flaw detection of various materials. It is remarked to use introscopes for testing of thick welded products articles, and X-ray vidicon systems for study of low-contrast images (in testing of welds made by point welding, and of thin-wall products)

  8. THE SPECTACULAR RADIO-NEAR-IR-X-RAY JET OF 3C 111: THE X-RAY EMISSION MECHANISM AND JET KINEMATICS

    Energy Technology Data Exchange (ETDEWEB)

    Clautice, Devon; Perlman, Eric S. [Department of Physics and Space Sciences, Florida Institute of Technology, 150 W. University Boulevard, Melbourne, FL 32901 (United States); Georganopoulos, Markos [Department of Physics, University of Maryland—Baltimore County, 1000 Hilltop Circle, Baltimore, MD 21250 (United States); Lister, Matthew L.; Hogan, Brandon [Department of Physics and Astronomy, Purdue University, 525 Northwestern Avenue, West Lafayette, IN 47907 (United States); Tombesi, Francesco [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Cara, Mihai [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Marshall, Herman L. [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Kazanas, Demos [NASA’s Goddard Space Flight Center, Astrophysics Science Division, Code 663, Greenbelt, MD 20771 (United States)

    2016-08-01

    Relativistic jets are the most energetic manifestation of the active galactic nucleus (AGN) phenomenon. AGN jets are observed from the radio through gamma-rays and carry copious amounts of matter and energy from the sub-parsec central regions out to the kiloparsec and often megaparsec scale galaxy and cluster environs. While most spatially resolved jets are seen in the radio, an increasing number have been discovered to emit in the optical/near-IR and/or X-ray bands. Here we discuss a spectacular example of this class, the 3C 111 jet, housed in one of the nearest, double-lobed FR II radio galaxies known. We discuss new, deep Chandra and Hubble Space Telescope ( HST ) observations that reveal both near-IR and X-ray emission from several components of the 3C 111 jet, as well as both the northern and southern hotspots. Important differences are seen between the morphologies in the radio, X-ray, and near-IR bands. The long (over 100 kpc on each side), straight nature of this jet makes it an excellent prototype for future, deep observations, as it is one of the longest such features seen in the radio, near-IR/optical, and X-ray bands. Several independent lines of evidence, including the X-ray and broadband spectral shape as well as the implied velocity of the approaching hotspot, lead us to strongly disfavor the EC/CMB model and instead favor a two-component synchrotron model to explain the observed X-ray emission for several jet components. Future observations with NuSTAR , HST , and Chandra will allow us to further constrain the emission mechanisms.

  9. Quantitative X ray analysis system. User's manual and guide to X ray fluorescence technique

    International Nuclear Information System (INIS)

    2009-01-01

    This guide covers trimmed and re-arranged version 3.6 of the Quantitative X ray Analysis System (QXAS) software package that includes the most frequently used methods of quantitative analysis. QXAS is a comprehensive quantitative analysis package that has been developed by the IAEA through research and technical contracts. Additional development has also been carried out in the IAEA Laboratories in Seibersdorf where QXAS was extensively tested. New in this version of the manual are the descriptions of the Voigt-profile peak fitting, the backscatter fundamental parameters' and emission-transmission methods of chemical composition analysis, an expanded chapter on the X ray fluorescence physics, and completely revised and increased number of practical examples of utilization of the QXAS software package. The analytical data accompanying this manual were collected in the IAEA Seibersdorf Laboratories in the years 2006/2007

  10. X-ray spectral decomposition imaging system

    Energy Technology Data Exchange (ETDEWEB)

    1977-07-27

    Projection measurements are made of the transmitted X-ray beam in low and high energy regions. These are combined in a non-linear processor to produce atomic-number-dependent and density-dependent projection information. This information is used to provide cross-sectional images which are free of spectral-shift artifacts and completely define the specific material properties. The invention described herein was made in the course of work under a grant from the Department of Health, Education, and Welfare.

  11. Multi-Purpose X-ray System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Stellarray proposes the development of a highly novel Multi-Purpose X-ray Source and System (MPXS), for use on flight missions, space stations, planetary excursions...

  12. Multi-Purpose X-ray System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Multi-Purpose X-ray Source and System (MPXS) can be used on flight missions, space stations, planetary excursions and planetary or asteroid bases, to...

  13. System for Gamma an X rays fluorescence spectrometric

    International Nuclear Information System (INIS)

    Alonso Abad, D.; Arista Romeu, E.; Bolanos Perez, L. and others

    1997-01-01

    A system for spectrometry of gamma or fluorescence X rays is presented. It sis composed by a Si(Li) semiconductors detector, a charge sensitive preamplifier, a high voltage power supply, a spectrometric amplifier and a monolithic 1024 channels multichannel analyzers or an IBM compatible 4096 channels add - on- card multichannel analyzer. The system can be configured as a 1024 or 4096 channels gamma or fluorescent X rays spectrometer

  14. Exchange, x-ray and IR spectral behaviour of lanthanum and praseodymium exchanged zeolite X

    International Nuclear Information System (INIS)

    Das, D.; Upreti, M.C.

    1995-01-01

    Exchange behaviour of lanthanum and praseodymium ions in zeolite X involves three steps: preferential exchange, intrazeolitic exchange and irreversible exchange. At room temperature , higher exchange has been observed with La(III) than with Pr(III) which is attributed to the smaller hydrosphere of lanthanum than praseodymium. IR spectra of these zeolites in KBr pellets show a shift in the major Si-O stretching vibration of 972 cm -1 to higher frequencies. Their x-ray diffraction patterns remain unchanged except a large decrease of the line intensities caused by the absorption of x-rays by heavy La(III) and Pr(III) ions. The present study reports the preparation and physicochemical properties of lanthanum and praseodymium exchanged zeolite X. (author). 12 refs., 3 figs., 3 tabs

  15. Probing single magnon excitations in Sr₂IrO₄ using O K-edge resonant inelastic x-ray scattering.

    Science.gov (United States)

    Liu, X; Dean, M P M; Liu, J; Chiuzbăian, S G; Jaouen, N; Nicolaou, A; Yin, W G; Rayan Serrao, C; Ramesh, R; Ding, H; Hill, J P

    2015-05-27

    Resonant inelastic x-ray scattering (RIXS) at the L-edge of transition metal elements is now commonly used to probe single magnon excitations. Here we show that single magnon excitations can also be measured with RIXS at the K-edge of the surrounding ligand atoms when the center heavy metal elements have strong spin-orbit coupling. This is demonstrated with oxygen K-edge RIXS experiments on the perovskite Sr2IrO4, where low energy peaks from single magnon excitations were observed. This new application of RIXS has excellent potential to be applied to a wide range of magnetic systems based on heavy elements, for which the L-edge RIXS energy resolution in the hard x-ray region is usually poor.

  16. Two digital X-ray imaging systems for applications in X-ray diffraction

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Flesher, A.C.; Tucker, P.A.; Swanton, S.W.

    1987-01-01

    Two digital X-ray imaging systems developed at the Rutherford Appleton Laboratory are described: the Mark I and the Mark II. Both use a bidimensionally sensitive multiwire proportional counter (MWPC) as the basic X-ray image transducer coupled, in the case of the Mark I to a Digital LSI 11-23 microcomputer system via CAMAC, and in the case of the Mark II to a Digital LSI 11-73 microcomputer system via custom-built data acquisition hardware mounted directly on the Q-bus of the microcomputer. The Mark I system provides the advantages of high speed, high sensitivity digital imaging directly into the computer with the potential for software control of the sample orientation and environment. The Mark II system adds the novel features of signal averaging and multiframe exposures. The dedicated digital memories have a resolution of 512x512 pixels of 16 bits, matching well to the spatial resolution of the xenon-filled MWPC (0.5 mm fwhm over an aperture of 200 mm x 200 mm). A 512x512x4 bit video graphics system displays the images in grey scales or colour. (orig.)

  17. Phase-matched generation of coherent soft and hard X-rays using IR lasers

    Science.gov (United States)

    Popmintchev, Tenio V.; Chen, Ming-Chang; Bahabad, Alon; Murnane, Margaret M.; Kapteyn, Henry C.

    2013-06-11

    Phase-matched high-order harmonic generation of soft and hard X-rays is accomplished using infrared driving lasers in a high-pressure non-linear medium. The pressure of the non-linear medium is increased to multi-atmospheres and a mid-IR (or higher) laser device provides the driving pulse. Based on this scaling, also a general method for global optimization of the flux of phase-matched high-order harmonic generation at a desired wavelength is designed.

  18. Condenser discharge system mobile x-ray apparatus MC 125L-30

    International Nuclear Information System (INIS)

    Kohsaka, Mitsuo; Sasaki, Masahiro; Ozawa, Yasushi; Nakanishi, Takeshi; Matsushita, Yoshiyuki

    1978-01-01

    Improvement of x-ray image quality and safety are strongly required of the x-ray system. This applies equally in the case of the mobile type x-ray system. To satisfy the requirements, the new mobile type x-ray system equipped with the improved x-ray tube unit, collimator, mobile unit and x-ray high tension unit has been developed. In this unit mobility and maneuverability are also improved by introducing a new method. (author)

  19. Infrared (IR) vs x-ray power generation in the SLAC Linac Coherent Light Source (LCLS)

    International Nuclear Information System (INIS)

    Tatchyn, R.

    1993-05-01

    The LCLS, a Free-Electron Laser (FEL) designed for operation at a first harmonic energy of 300 eV (λ congruent 40 Angstrom) in the Self-Amplified Spontaneous Emission (SASE) regime, will utilize electron bunches compressed down to durations of <0.5ps, or lengths of <150 μ. It is natural to inquire whether coherent radiation of this (and longer) wavelength will constitute a significant component of the total coherent output of the FEL. In this paper a determination of a simple upper bound on the IR that can be generated by the compressed bunches is outlines. Under the assumed operating parameters of the LCLS undulator, it is shown that that IR component of the coherent output should be strongly dominated by the x-ray component

  20. Laboratory evaluation of two x-ray baggage inspection systems

    International Nuclear Information System (INIS)

    Schellenbaum, R.L.

    1979-06-01

    The AS and E Micro-Dose X-ray Baggage Inspection System was designed for high-volume, detailed examination of packages at ultralow x-ray exposure levels. This system is used in airline terminals for the detection of weapons, bombs, and other contraband. It is also employed by security personnel in other facilities to search packages for contraband carried in and out of secured areas. The Micro-Dose system has a unique design concept which includes an Automatic Threat Alert System (ATA) and a zoom display presentation feature

  1. Computerized x-ray dose-monitoring system

    International Nuclear Information System (INIS)

    Hummel, R.H.; Wesenberg, R.L.; Amundson, G.M.

    1985-01-01

    An x-ray dose-monitoring system using a small digital computer is described. Initially, and for every 6 months afterward, the system is calibrated using an exposure meter. For each exposure, the computer receives values of x-ray technique and beam geometry from the x-ray generator through a specially designed electronic interface. Then, by means of calibration data, entrance exposure, area exposure product, and integral dose are obtained and printed for each patient examined. The overall accuracy of the system is better than +/-20%. Operation is semiautomatic, requiring minimum operator intervention. Over 2000 patients have been monitored with the device. Because the system is computer-based, it offers the opportunity for statistical analysis of the data base created, as the results for each patient are stored on computer disk

  2. A readout system for X-ray powder crystallography

    CERN Document Server

    Loukas, D; Pavlidis, A; Karvelas, E; Psycharis, K; Misiakos, V; Mousa, J; Dre, C

    2000-01-01

    A system for capturing and processing data, from radiation detectors, in the field of X-ray crystallography has been developed. The system includes a custom-made mixed analog-digital 16-channel VLSI circuit in 50 mu m pitch. Each channel comprises a charge amplifier, a shaper, a comparator and a 21-bit counter. The circuit can be scaled in a daisy chain configuration. Data acquisition is performed with a custom made PCI card while the control software is developed with Visual C++ under the MS Windows NT environment. Performance of a fully operational system, in terms of electronic noise, statistical variations and data capture speed is presented. The noise level permits counting of X-rays down to 8 keV while the counting capability is in excess of 200 kHz. The system is intended for X-ray crystallography with silicon detectors.

  3. Image quality of medical X-ray systems

    International Nuclear Information System (INIS)

    Hoen, P.J. 't.

    1980-01-01

    The quality of images made by medical X-ray systems can only be properly described if the visual system is also taken into account. In this thesis, the visual threshold contrast of edges, bars and disks has been chosen as the criterion. Since these objects resemble medical objects like tumour-mass outlines, blood vessels and micro-calcifications, a correlation with X-ray practice is possible. Only the conventional X-ray systems are considered, but a brief analysis of computerized tomography is given. Considerable attention is paid to unsharpness and the minimization of its influence on the threshold contrast, to the influence of the noise on the threshold contrast, and to the contrast formation as such. The consequences for the dose administered to the patient are also briefly analysed. (Auth.)

  4. Semi-automated x-ray gauging process control system

    International Nuclear Information System (INIS)

    Draut, C.F.; Homan, D.A.

    1976-01-01

    An x-ray gauging method was developed and a production gauging system was subsequently fabricated to control the quality of precision manufactured components. The gauging system measures via x-ray absorption the density of pressed finely divided solids held in a dissimilar container. The two dissimilar materials condition necessitated a ''two scan'' technique: first, the x-ray attenuation (absorption) of the empty container prior to loading and then, the attenuation of the loaded container are measured; that is, four variables. The system provided greatly improved product control via timely data feedback and increased product quality assurance via 100 percent inspection of product. In addition, it reduced labor costs, product cost, and possibilities for human errors

  5. Stellar winds in binary X-ray systems

    Science.gov (United States)

    Macgregor, K. B.; Vitello, P. A. J.

    1982-01-01

    It is thought that accretion from a strong stellar wind by a compact object may be responsible for the X-ray emission from binary systems containing a massive early-type primary. To investigate the effect of X-ray heating and ionization on the mass transfer process in systems of this type, an idealized model is constructed for the flow of a radiation-driven wind in the presence of an X-ray source of specified luminosity, L sub x. It is noted that for low values of L sub x, X-ray photoionization gives rise to additional ions having spectral lines with wavelengths situated near the peak of the primary continuum flux distribution. As a consequence, the radiation force acting on the gas increases in relation to its value in the absence of X-rays, and the wind is accelerated to higher velocities. As L sub x is increased, the degree of ionization of the wind increases, and the magnitude of the radiation force is diminished in comparison with the case in which L sub x = 0. This reduction leads at first to a decrease in the wind velocity and ultimately (for L sub x sufficiently large) to the termination of radiatively driven mass loss.

  6. Computerized x-ray radiographic system for fuel pellet measurements

    International Nuclear Information System (INIS)

    Green, D.R.; Karnesky, R.A.; Bromley, C.

    1977-01-01

    The development and operation of a computerized system for determination of fuel pellet diameters from x-ray radiography is described. Actual fuel pellet diameter measurements made with the system are compared to micrometer measurements on the same pellets, and statistically evaluated. The advantages and limitations of the system are discussed, and recommendations are made for further development

  7. Structural investigations on some cadmium-borotellurate glasses using ultrasonic, FT-IR and X-ray techniques

    Energy Technology Data Exchange (ETDEWEB)

    Gaafar, M.S., E-mail: m.gaafar@mu.edu.sa [Physics Department, College of Sciences, Majmaah University (Saudi Arabia); Ultrasonic Laboratory, National Institute for Standards, Tersa Str., P.O. Box 136, El-Haram, El-Giza 12211 (Egypt); Shaarany, I. [Physics Department, College of Sciences, Majmaah University (Saudi Arabia); Physics Department, Faculty of Science, Suez Canal University, Ismailia (Egypt); Alharbi, T. [Physics Department, College of Sciences, Majmaah University (Saudi Arabia)

    2014-12-15

    Highlights: • 50B{sub 2}O{sub 3}–(50 – x)TeO{sub 2}–xCdO glass system has been prepared by melt quenching technique. • Both sound velocities decrease with increase in x. • Studies on the structure of these glasses, have revealed that Cd{sup 2+} ions are incorporated in the form of CdO{sub 6}. - Abstract: Glasses in the system 50B{sub 2}O{sub 3}–(50 − x)TeO{sub 2}–xCdO with different CdO contents (0, 10, 20, 30, 40 and 50 mol%), have been prepared by melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of CdO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increase and the molar volume decrease while both sound velocities decrease with increase in x. Elastic properties, FT-IR and X-ray diffraction studies on the network structure of these glass structures, have revealed that Cd{sup 2+} ions are incorporated in the form of CdO{sub 6}, decreasing the molar volume and compensate for the decrease in the average coordination number of tellurium atoms which was the reason for the increase in elastic moduli.

  8. Human engineering design of medical x-ray system

    International Nuclear Information System (INIS)

    Tohma, Hideo

    1981-01-01

    There have been remarkable progress in the area of X-ray diagnosis technology in recent years. However, there have been some cases of accident. Such accidents included those due to defective apparatus such as defects in apparatus and poor safety system, those caused by incorrect handling of apparatus by radiologic technologist, and those originating in a poor surrounding condition or bad management of apparatus. In this report, the following subjects are statistically studied: 1. Analysis of radiographic error. 2. Analysis of failure in medical X-ray systems. (author)

  9. Tire inspection system with shielded x-ray source

    International Nuclear Information System (INIS)

    Heisner, D.N.; Palermo, A. Jr.; Loyer, P.K.

    1976-01-01

    An automated tire inspection system is described which employs a penetrative radiation, such as x-radiation, to inspect the integrity of portions of tires fed sequentially along a feed path through a centering station and into a shielded enclosure where an inspection station is defined. Features of the system include a continuously operating x-ray source movable between inspection and retracted positions, and an x-ray shield for covering the source when it is retracted to permit the doors of the shielded enclosure to be opened without danger from escaping radiation. 19 Claims, 38 Drawing Figures

  10. 21 CFR 892.1750 - Computed tomography x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Computed tomography x-ray system. 892.1750 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1750 Computed tomography x-ray system. (a) Identification. A computed tomography x-ray system is a diagnostic x-ray system intended to...

  11. Observational studies of X-ray binary systems

    International Nuclear Information System (INIS)

    Klis, M. van der.

    1983-01-01

    The subject of Chapter 1 is theoretical. The other chapters, Ch. 2 to 6, contain original observational data and efforts towards their interpretation. Of these, Ch. 3, 4 and 5 deal with massive X-ray binaries, Ch. 6 with low-mass systems and Ch. 2 with Cygnus X-3, which we have not yet been able to assign to any of these two classes. The X-ray observations described were made with the COS-B satellite. Work based on UV and optical observations is described in Ch. 5. The UV observations were made with the IUE satellite, the optical observations at several ground-based observatories. (Auth.)

  12. Miniature, mobile X-ray computed radiography system

    Science.gov (United States)

    Watson, Scott A; Rose, Evan A

    2017-03-07

    A miniature, portable x-ray system may be configured to scan images stored on a phosphor. A flash circuit may be configured to project red light onto a phosphor and receive blue light from the phosphor. A digital monochrome camera may be configured to receive the blue light to capture an article near the phosphor.

  13. A portable tube exciting X-ray fluorescence analysis system

    International Nuclear Information System (INIS)

    Yang Qiang; Lai Wanchang; Ge Liangquan

    2009-01-01

    Article introduced a portable tube exciting X-ray fluorescence analysis system which is based on arm architecture. Also, we designed Tube control circuit and finished preliminary application. The energy and the intensity of the photon can be adjusted continuously by using the tube. Experiments show that high excitation efficiency obtained by setting the appropriate parameters of the tube for the various elements. (authors)

  14. X-ray diffraction, IR spectroscopy and thermal characterization of partially hydrolyzed guar gum.

    Science.gov (United States)

    Mudgil, Deepak; Barak, Sheweta; Khatkar, B S

    2012-05-01

    Guar gum was hydrolyzed using cellulase from Aspergillus niger at 5.6 pH and 50°C temperature. Hydrolyzed guar gum sample was characterized using Fourier transform infrared spectroscopy, differential scanning calorimetry, thermogravimetric analysis, X-ray diffraction, dilute solution viscometry and rotational viscometry. Viscometry analysis of native guar gum showed a molecular weight of 889742.06, whereas, after enzymatic hydrolysis, the resultant product had a molecular weight of 7936.5. IR spectral analysis suggests that after enzymatic hydrolysis of guar gum there was no major transformation of functional group. Thermal analysis revealed no major change in thermal behavior of hydrolyzed guar gum. It was shown that partial hydrolysis of guar gum could be achieved by inexpensive and food grade cellulase (Aspergillus niger) having commercial importance and utilization as a functional soluble dietary fiber for food industry. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Development of a 3-D X-ray system

    Science.gov (United States)

    Evans, James Paul Owain

    The interpretation of standard two-dimensional x-ray images by humans is often very difficult. This is due to the lack of visual cues to depth in an image which has been produced by transmitted radiation. The solution put forward in this research is to introduce binocular parallax, a powerful physiological depth cue, into the resultant shadowgraph x-ray image. This has been achieved by developing a binocular stereoscopic x-ray imaging technique, which can be used for both visual inspection by human observers and also for the extraction of three-dimensional co-ordinate information. The technique is implemented in the design and development of two experimental x-ray systems and also the development of measurement algorithms. The first experimental machine is based on standard linear x-ray detector arrays and was designed as an optimum configuration for visual inspection by human observers. However, it was felt that a combination of the 3-D visual inspection capability together with a measurement facility would enhance the usefulness of the technique. Therefore, both a theoretical and an empirical analysis of the co-ordinate measurement capability of the machine has been carried out. The measurement is based on close-range photogrammetric techniques. The accuracy of the measurement has been found to be of the order of 4mm in x, 3mm in y and 6mm in z. A second experimental machine was developed and based on the same technique as that used for the first machine. However, a major departure has been the introduction of a dual energy linear x-ray detector array which will allow, in general, the discrimination between organic and inorganic substances. The second design is a compromise between ease of visual inspection for human observers and optimum three-dimensional co-ordinate measurement capability. The system is part of an on going research programme into the possibility of introducing psychological depth cues into the resultant x-ray images. The research presented in

  16. X-ray-phase and IR-spectral study of clay rocks mineral content of the Caspian Sea Gulf depression

    International Nuclear Information System (INIS)

    Zakonov, A.N.; Mukhanova, M.U.

    2000-01-01

    Samples of clays selected from different oil fields (Sazankurak, Kemerkol, Kozha and others) and deposition depths are examined on both the X-ray diffractometers (Dron-2 and Dron-4) and the infrared-spectrometers (IR-20). In this diagnostic the American file with different minerals X-ray systematized data is used. The X-ray reflections, which are in compliance with suitable inter-plane distances and clay impurities reflex intensities are determined. With confirmation purpose for mineral content correctness obtained according X-ray-phase analysis the infrared-spectrometric method is used, in which principal attention was paid to absorption field (3,400-3,700 cm -1 ) of H 2 O and OH valency frequency vibrations

  17. X-ray television system, SHIMAVISION 3200X

    International Nuclear Information System (INIS)

    Nagata, Takashi; Takemoto, Hajime; Nakamura, Masanori; Imanishi, Tetsuo

    1990-01-01

    X-ray television system 'SHIMAVISION 3200X' has been developed. This system has achieved large image size in radiography and fluoroscopy utilizing up to 17inch x 14inch cassette radiographic function attached to 2 channel 3 size cassetteless spotfilm device and utilizing 12inch I.I. at same table top height as 9inch I.I. Newly designed image processor makes fluoroscopic image high quality. (author)

  18. Design and fabrication of micro X-ray diffraction system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yang Soon; Han, Sun Ho; Kim, Jong Goo; Jee, Kwang Yong

    2006-10-15

    It has been observed that microstructure changes occur at the pellet periphery(rim) of the fuel at very high burn-up. Despite its narrow range (below some hundreds microns in depth), this peripheral region(rim) determines the behaviour of nuclear fuel. To determine lattice parameter with XRD at intervals as small as 30-50 {mu} m in radial direction of irradiated fuel samples, a micro X-ray diffraction system was designed and fabricated. This report describes the micro X-ray diffraction system consisted of an X-ray microbeam alignment system and a sample micro translation system, its characterization, and its performance test through the analysis for the micro region of some specimens. This system will be set in a radiation shielded glove box, and then used for analysis of lattice parameter change and the phase change at intervals as small as 30-50 {mu} m in radial direction of the rim of an irradiated fuel sample and a fuel cladding.

  19. Design and fabrication of micro X-ray diffraction system

    International Nuclear Information System (INIS)

    Park, Yang Soon; Han, Sun Ho; Kim, Jong Goo; Jee, Kwang Yong

    2006-10-01

    It has been observed that microstructure changes occur at the pellet periphery(rim) of the fuel at very high burn-up. Despite its narrow range (below some hundreds microns in depth), this peripheral region(rim) determines the behaviour of nuclear fuel. To determine lattice parameter with XRD at intervals as small as 30-50 μ m in radial direction of irradiated fuel samples, a micro X-ray diffraction system was designed and fabricated. This report describes the micro X-ray diffraction system consisted of an X-ray microbeam alignment system and a sample micro translation system, its characterization, and its performance test through the analysis for the micro region of some specimens. This system will be set in a radiation shielded glove box, and then used for analysis of lattice parameter change and the phase change at intervals as small as 30-50 μ m in radial direction of the rim of an irradiated fuel sample and a fuel cladding

  20. Solution Structures of Highly Active Molecular Ir Water-Oxidation Catalysts from Density Functional Theory Combined with High-Energy X-ray Scattering and EXAFS Spectroscopy.

    Science.gov (United States)

    Yang, Ke R; Matula, Adam J; Kwon, Gihan; Hong, Jiyun; Sheehan, Stafford W; Thomsen, Julianne M; Brudvig, Gary W; Crabtree, Robert H; Tiede, David M; Chen, Lin X; Batista, Victor S

    2016-05-04

    The solution structures of highly active Ir water-oxidation catalysts are elucidated by combining density functional theory, high-energy X-ray scattering (HEXS), and extended X-ray absorption fine structure (EXAFS) spectroscopy. We find that the catalysts are Ir dimers with mono-μ-O cores and terminal anionic ligands, generated in situ through partial oxidation of a common catalyst precursor. The proposed structures are supported by (1)H and (17)O NMR, EPR, resonance Raman and UV-vis spectra, electrophoresis, etc. Our findings are particularly valuable to understand the mechanism of water oxidation by highly reactive Ir catalysts. Importantly, our DFT-EXAFS-HEXS methodology provides a new in situ technique for characterization of active species in catalytic systems.

  1. 3D X-Ray Luggage-Screening System

    Science.gov (United States)

    Fernandez, Kenneth

    2006-01-01

    A three-dimensional (3D) x-ray luggage- screening system has been proposed to reduce the fatigue experienced by human inspectors and increase their ability to detect weapons and other contraband. The system and variants thereof could supplant thousands of xray scanners now in use at hundreds of airports in the United States and other countries. The device would be applicable to any security checkpoint application where current two-dimensional scanners are in use. A conventional x-ray luggage scanner generates a single two-dimensional (2D) image that conveys no depth information. Therefore, a human inspector must scrutinize the image in an effort to understand ambiguous-appearing objects as they pass by at high speed on a conveyor belt. Such a high level of concentration can induce fatigue, causing the inspector to reduce concentration and vigilance. In addition, because of the lack of depth information, contraband objects could be made more difficult to detect by positioning them near other objects so as to create x-ray images that confuse inspectors. The proposed system would make it unnecessary for a human inspector to interpret 2D images, which show objects at different depths as superimposed. Instead, the system would take advantage of the natural human ability to infer 3D information from stereographic or stereoscopic images. The inspector would be able to perceive two objects at different depths, in a more nearly natural manner, as distinct 3D objects lying at different depths. Hence, the inspector could recognize objects with greater accuracy and less effort. The major components of the proposed system would be similar to those of x-ray luggage scanners now in use. As in a conventional x-ray scanner, there would be an x-ray source. Unlike in a conventional scanner, there would be two x-ray image sensors, denoted the left and right sensors, located at positions along the conveyor that are upstream and downstream, respectively (see figure). X-ray illumination

  2. Quasi-simultaneous observations of BL Lac object Mrk 501 in X-ray, UV, visible, IR, and radio frequencies

    Science.gov (United States)

    Kondo, Y.; Worrall, D. M.; Oke, J. B.; Yee, H. K. C.; Neugebauer, G.; Matthews, K.; Feldman, P. A.; Mushotzky, R. F.; Hackney, R. L.; Hackney, K. R. H.

    1981-01-01

    Observations in the X-ray, UV, visible, IR and radio regions of the BL Lac object Mrk 501 made over the course of two months are reported. The measurements were made with the A2 experiment on HEAO 1 (X-ray), the SWP and LWR cameras on IUE (UV), the 5-m Hale telescope (visible), the 2.5-m telescope at Mount Wilson (IR), the NRAO 92-m radio telescope at Green Bank (4750 MHz) and the 46-m radio telescope at the Algonquin Observatory (10275 and 10650 MHz). The quasi-simultaneously observed spectral slope is found to be positive and continuous from the X-ray to the UV, but to gradually flatten and possibly turn down from the mid-UV to the visible; the optical-radio emission cannot be accounted for by a single power law. The total spectrum is shown to be compatible with a synchrotron self-Compton emission mechanism, while the spectrum from the visible to the X-ray is consistent with synchrotron radiation or inverse-Compton scattering by a hot thermal electron cloud. The continuity of the spectrum from the UV to the X-ray is noted to imply a total luminosity greater than previous estimates by a factor of 3-4.

  3. Free-air ionization chamber, FAC-IR-300, designed for medium energy X-ray dosimetry

    International Nuclear Information System (INIS)

    Mohammadi, S.M.; Tavakoli-Anbaran, H.; Zeinali, H.Z.

    2017-01-01

    The primary standard for X-ray photons is based on parallel-plate free-air ionization chamber (FAC). Therefore, the Atomic Energy Organization of Iran (AEOI) is tried to design and build the free-air ionization chamber, FAC-IR-300, for low and medium energy X-ray dosimetry. The main aim of the present work is to investigate specification of the FAC-IR-300 ionization chamber and design it. FAC-IR-300 dosimeter is composed of two parallel plates, a high voltage (HV) plate and a collector plate, along with a guard electrode that surrounds the collector plate. The guard plate and the collector were separated by an air gap. For obtaining uniformity in the electric field distribution, a group of guard strips was used around the ionization chamber. These characterizations involve determining the exact dimensions of the ionization chamber by using Monte Carlo simulation and introducing correction factors.

  4. Design of the free-air ionization chamber, FAC-IR-150, for X-ray dosimetry

    Science.gov (United States)

    Mohammadi, Seyed Mostafa; Tavakoli-Anbaran, Hossein

    2018-03-01

    The primary standard for X-ray dosimetry is based on the free-air ionization chamber (FAC). Therefore, the Atomic Energy Organization of Iran (AEOI) designed the free-air ionization chamber, FAC-IR-150, for low and medium energy X-ray dosimetry. The purpose of this work is the study of the free-air ionization chamber characteristics and the design of the FAC-IR-150. The FAC-IR-150 dosimeter has two parallel plates, a high voltage plate and a collector plate. A guard electrode surrounds the collector and is separated by an air gap. A group of guard strips is used between up and down electrodes to produce a uniform electric field in all the ion chamber volume. This design involves introducing the correction factors and determining the exact dimensions of the ionization chamber by using Monte Carlo simulation.

  5. Combined optic system based on polycapillary X-ray optics and single-bounce monocapillary optics for focusing X-rays from a conventional laboratory X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Xuepeng; Liu, Zhiguo [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Sun, Tianxi, E-mail: stx@bnu.edu.cn [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Yi, Longtao; Sun, Weiyuan; Li, Fangzuo; Jiang, Bowen [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Ma, Yongzhong [Center for Disease Control and Prevention of Beijing, Beijing 100013 (China); Ding, Xunliang [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2015-12-01

    Two combined optic systems based on polycapillary X-ray optics and single-bounce monocapillary optics (SBMO) were designed for focusing the X-rays from a conventional laboratory X-ray source. One was based on a polycapillary focusing X-ray lens (PFXRL) and a single-bounce ellipsoidal capillary (SBEC), in which the output focal spot with the size of tens of micrometers of the PFXRL was used as the “virtual” X-ray source for the SBEC. The other system was based on a polycapillary parallel X-ray lens (PPXRL) and a single-bounce parabolic capillary (SBPC), in which the PPXRL transformed the divergent X-ray beam from an X-ray source into a quasi-parallel X-ray beam with the divergence of sever milliradians as the incident illumination of the SBPC. The experiment results showed that the combined optic systems based on PFXRL and SBEC with a Mo rotating anode X-ray generator with the focal spot with a diameter of 300 μm could obtain a focal spot with the total gain of 14,300 and focal spot size of 37.4 μm, and the combined optic systems based on PPXRL and SBPC with the same X-ray source mentioned above could acquire a focal spot with the total gain of 580 and focal spot size of 58.3 μm, respectively. The two combined optic systems have potential applications in micro X-ray diffraction, micro X-ray fluorescence, micro X-ray absorption near edge structure, full field X-ray microscopes and so on.

  6. Physician-received scatter radiation with angiography systems used for interventional radiology: Comparison among many x-ray systems

    International Nuclear Information System (INIS)

    Chida, K.; Morishima, Y.; Inaba, Y.; Taura, M.; Ebata, A.; Takeda, K.; Shimura, H.; Zuguchi, M.

    2012-01-01

    Radiation protection for interventional radiology (IR) physicians is very important. Current IR X-ray systems tend to use flat-panel detectors (FPDs) rather than image intensifiers (IIs). The purpose of this study is to test the hypothesis that there is no difference in physician-received scatter radiation (PRSR) between FPD systems and II systems. This study examined 20 X-ray systems in 15 cardiac catheterisation laboratories (11 used a FPD and 9 used an II). The PRSR with digital cine-angiography and fluoroscopy were compared among the 20 X-ray systems using a phantom and a solid-state-detector electronic pocket dosemeter. The maximum PRSR exceeded the minimum PRSR by ∼12-fold for cine-angiography and ∼9-fold for fluoroscopy. For both fluoroscopy and digital cine-angiography, the PRSR had a statistically significant positive correlation with the entrance surface dose (fluoroscopy, r = 0.87; cine-angiography, r = 0.86). There was no statistically significant difference between the average PRSR of FPDs and IIs during either digital cine-angiography or fluoroscopy. There is a wide range of PRSR among the radiography systems evaluated. The PRSR correlated well with the entrance surface dose of the phantom in 20 X-ray units used for IR. Hence, decreasing the dose to the patient will also decrease the dose to staff. (authors)

  7. 21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.

    Science.gov (United States)

    2010-04-01

    ... fluoroscopic x-ray system. (a) Identification. An image-intensified fluoroscopic x-ray system is a device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Image-intensified fluoroscopic x-ray system. 892... equipment, patient and equipment supports, component parts, and accessories. (b) Classification. Class II...

  8. 21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.

    Science.gov (United States)

    2010-04-01

    ... fluoroscopic x-ray system. (a) Identification. A non-image-intensified fluoroscopic x-ray system is a device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Non-image-intensified fluoroscopic x-ray system... display equipment, patient and equipment supports, component parts, and accessories. (b) Classification...

  9. Computerized tomographic x-ray scanner system and gantry assembly

    International Nuclear Information System (INIS)

    Doyd, D.P.; Lanzara, G.

    1991-01-01

    This patent describes a scanner assembly. It comprises: a support head, a C-shaped gantry, means for supporting the gantry in the support head for rotating movement, an x-ray source mounted on one side of the gantry for independent movement with respect to a detector array along the gantry, the x-ray source projecting x-rays across the gantry, and a detector array mounted on the other side of a gantry for independent movement with respect to the x-ray source along the gantry, the detector array serving to receive the projected x-rays

  10. 21 CFR 872.1810 - Intraoral source x-ray system.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1810 Intraoral source x-ray system. (a... structures. The x-ray source (a tube) is located inside the mouth. This generic type of device may include... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraoral source x-ray system. 872.1810 Section...

  11. X-ray Jets in the CH Cyg Symbiotic System

    Science.gov (United States)

    Karovska, Margarita; Gaetz, T.; Lee, N.; Raymond, J.; Hack, W.; Carilli, C.

    2009-09-01

    Symbiotic binaries are interacting systems in which a compact stellar source accretes matter from the wind of the cool evolved companion. There are a few hundred symbiotic systems known today, but jet activity has been detected in only a few of them, including in CH Cyg. CH Cyg is a symbiotic system that has shown significant activity since the mid 1960s. Jets have been detected in optical and radio since 1984, and more recently in 2001 in X-rays using Chandra observations.In 2008 we carried out coordinated multi-wavelength observations of the CH Cyg system with Chandra, HST, and the VLA, in order to study the propagation and interaction with the circumbinary medium of the jet detected in 2001. We report here on the detection of the 2001 SE jet which has expanded in seven years from ˜350AU to ˜1400 AU. The apex of the loop delineating the region of interaction with the circumbinary matter is moving with a speed of ˜700 km/s. Assuming a linear expansion, the jet was launched during the 1999-2000 active phase. We also report on a detection of a powerful new jet in the SW direction, observed in X-ray, optical and radio wavelengths. The new jet has a multi-component structure including an inner jet and counter jet, and a SW component ending in several clumps extending up to a distance of about 750AU.

  12. A laboratory based x-ray reflectivity system

    International Nuclear Information System (INIS)

    Holt, S.A.; Creagh, D.C.; Jamie, I.M.; Dowling, T.L.; Brown, A.S.

    1996-01-01

    Full text: X-ray Reflectivity (XRR) over the last decade has proved to be a versatile and powerful technique by which the thickness of thin films, surface roughness and interface roughness can be determined. The systems amenable to study range from organic monolayers (liquid or solid substrates) to layered metal or semiconductor systems. Access to XRR has been limited by the requirement for synchrotron radiation sources. The development of XRR systems for the laboratory environment was pioneered by Weiss. An X-ray Reflectometer has been constructed by the Department of Physics (Australian Defence Force Academy) and the Research School of Chemistry (Australian National University). The general principles of the design were similar to those described by Weiss. The reflectometer is currently in the early stages of commissioning, with encouraging results thus far. The diffraction pattern of Mobil Catalytic Material (MCM), consisting primarily of SiO 2 . The poster will describe the reflectometer, its operation and present a summary of the most important results obtained to date

  13. Current status of X-ray system at SHI Tsukuba facility

    International Nuclear Information System (INIS)

    Washio, Masakazu; Kato, Hiroo; Yamase, Yutaka; Odera, Masatoshi; Thompson, C.C.; Cleland, M.R.

    1992-01-01

    Many studies have been carried out on X-ray converter system, characteristics of the X-rays and its applications. In this paper, following items will be described. 1. Characteristics of electron beam obtained from 5 MeV Dynamitron, 2. Design and status of the X-ray converter, 3. Characteristics of converted X-ray, 4. Preliminary results of sterilization of certain microbiological reference standard. (J.P.N.)

  14. Ultra-short wavelength x-ray system

    Science.gov (United States)

    Umstadter, Donald [Ann Arbor, MI; He, Fei [Ann Arbor, MI; Lau, Yue-Ying [Potomac, MD

    2008-01-22

    A method and apparatus to generate a beam of coherent light including x-rays or XUV by colliding a high-intensity laser pulse with an electron beam that is accelerated by a synchronized laser pulse. Applications include x-ray and EUV lithography, protein structural analysis, plasma diagnostics, x-ray diffraction, crack analysis, non-destructive testing, surface science and ultrafast science.

  15. Radiation exposure with the NOMAD portable X-ray system.

    Science.gov (United States)

    Goren, A D; Bonvento, M; Biernacki, J; Colosi, D C

    2008-02-01

    A new hand-held battery-operated portable X-ray system was tested for possible leakage radiation through the existing heavy metal compounds surrounding the X-ray tube, backscatter radiation through the lead-filled acrylic shield attached at the end of the exit tube and patient exposure. Dose measurements were conducted using a DXTRR phantom and a water phantom. All measurements were recorded using calibrated thermoluminescent dosimetry (TLD), calibrated Unfors Model 583L dosemeter, and a calibrated Radcal MDH model 1015 dosemeter. The settings for all exposure were 60 kVp, 2.3 mA and 0.25 s using Kodak Insight (Class F) film. All backscatter measurements, in front of the shield, behind the shield, at the finger of the operator, the operator's chest, eyes and gonads were significantly below the maximum permissible radiation leakage as per the United States Food and Drug Administration regulations (100 mR h(-1)). Our measurements indicate that the exposure would be well within the occupational maximum permissible dose for an occupationally exposed person. Film dose was consistent with the manufacturer's recommendations. As a result of our measurements, the State of New York Bureau of Environmental Radiation Protection granted us a variance to use the NOMAD on a case-by-case basis. Our data have shown that the NOMAD presents risks that are no greater than with standard dental radiographic units to the patient or operator and the measured doses are well below recommended levels.

  16. Gamma detector for use with luggage X-ray systems

    International Nuclear Information System (INIS)

    McHugh, H.; Quam, W.

    1998-01-01

    A new gamma radiation sensor has been designed for installation on several types of luggage x-ray machines and mobile x-ray vans operated by the U.S. Customs Service and the U.S. Department of State. The use of gamma detectors on x-ray machines imposed difficulties not usually encountered in the design of gamma detectors because the spectrum of scattered x-rays, which varied from machine to machine, extended to energies significantly higher than those of the low-energy isotopic emissions. In the original design, the lower level discriminator was raised above the x-ray end point energy resulting in the loss of the americium line associated with plutonium. This reduced the overall sensitivity to unshielded plutonium by a factor of approximately 100. An improved method was subsequently developed wherein collimation was utilized in conjunction with a variable counting threshold to permit accommodation of differing conditions of x-ray scattering. This design has been shown to eliminate most of the problems due to x-ray scattering while still capturing the americium emissions. The overall sensitivity has remained quite high, though varying slightly from one model of x-ray machine to another, depending upon the x-ray scattering characteristics of each model. (author)

  17. Exposure reduction in general dental practice using digital x-ray imaging system for intraoral radiography with additional x-ray beam filter

    International Nuclear Information System (INIS)

    Shibuya, Hitoshi; Mori, Toshimichi; Hayakawa, Yoshihiko; Kuroyanagi, Kinya; Ota, Yoshiko

    1997-01-01

    To measure exposure reduction in general dental practice using digital x-ray imaging systems for intraoral radiography with additional x-ray beam filter. Two digital x-ray imaging systems, Pana Digital (Pana-Heraus Dental) and CDR (Schick Technologies), were applied for intraoral radiography in general dental practice. Due to the high sensitivity to x-rays, additional x-ray beam filters for output reduction were used for examination. An Orex W II (Osada Electric Industry) x-ray generator was operated at 60 kVp, 7 mA. X-ray output (air-kerma; Gy) necessary for obtaining clinically acceptable images was measured at 0 to 20 cm in 5 cm steps from the cone tip using an ionizing chamber type 660 (Nuclear Associates) and compared with those for Ektaspeed Plus film (Eastman Kodak). The Pana Digital system was used with the optional filter supplied by Pana-Heraus Dental which reduced the output to 38%. The exposure necessary to obtain clinically acceptable images was only 40% of that for the film. The CDR system was used with the Dental X-ray Beam Filter Kit (Eastman Kodak) which reduced the x-ray output to 30%. The exposure necessary to obtain clinically acceptable images was only 20% of that for the film. The two digital x-ray imaging systems, Pana Digital and CDR, provided large dose savings (60-80%) compared with Ektaspeed Plus film when applied for intraoral radiography in general dental practice. (author)

  18. Study of the atomic ordering in the alloys Ni-Ir using diffuse X-ray scattering and pseudopotentials

    International Nuclear Information System (INIS)

    Abbas, T.

    1982-06-01

    Experiments were performed on the Ni-Ir alloys to measure the diffuse X-ray scattering intensity after annealing from high temperatures. It was established that the short-range order exists in these alloys when the samples are quenched from 1200 0 C and 1400 0 C. The ordering potentials for various concentrations of Ir in Ni were calculated using the pseudopotentials of Animalu. The method of incorporating the d electrons in the dielectric screening function was proposed. It was shown that the ordering potential is severely affected by the new type of screening. (author)

  19. System for calibration of instruments of x-ray measurement (CIR-X) applying the PGCS

    International Nuclear Information System (INIS)

    Gaytan G, E.; Rivero G, T.; Cruz E, P.; Tovar M, V.M.; Vergara M, F.J.

    2007-01-01

    The Department of Metrology of Ionizing Radiations of the ININ carries out calibration of instruments for X-ray measurement that determine the operation parameters in X-ray diagnostic machines of the health and private sectors. To facilitate this task, the Department of Automation and Instrumentation developed a system for acquisition and signals processing coming from a reference voltage divider with traceability at NIST that is connected directly to the X-rays tube. The system is integrated by the X-ray unit, the X-ray measurement equipment Dynalizer IIIU of RADCAL, a data acquisition card, a personal computer and the acquisition software and signals processing. (Author)

  20. CAMAC acquisition system for industrial X-ray tomograph

    International Nuclear Information System (INIS)

    Guerin, J.P.; Huet, Jacques; Pauton, Michel.

    1982-11-01

    A 400 kV X-ray industrial scanner has been developed. The present paper describes the CAMAC acquisition system. This unit with its 3 microprocessors, 2 mass memories and TV graphic display is very flexible; it will be used to optimise measurement parameters along with pieces to be checked and to establish application limits of this non destructive inspection method. This system allows internal inspection of objects as big as 400 mm in diameter with an elementary volume of 1 x 1 x 5 mm 3 and specific weight in the range of 0.7 to 10 g/cm 3 . Relative precision of 10 - 3 in density for moulded objects is expected. The first results obtained are shown [fr

  1. X-ray lasers: from star wars to benchtop systems

    International Nuclear Information System (INIS)

    Kuba, J.; Limpouch, J.; Drska, L.

    2005-01-01

    The paper is structured as follows: The principle of X-ray lasers; The transient scheme - an X-ray laser (maybe) on a laboratory bench; The experimental parameters of transient lasers show promise; and The nuclear gamma laser is one of the feasible pathways. (P.A.)

  2. Final Report - X-ray Studies of Highly Correlated Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Clement [Western Michigan Univ., Kalamazoo MI (United States)

    2017-11-27

    The overall goal of the research was to improve the capabilities of x-ray synchrotron instrumentation to enable cutting-edge research in condensed matter physics. The main goal of the current grant cycle was to find a method to measure the polarization of the scattered x-ray in resonant inelastic x-ray scattering. To do this, we developed a polarization analysis apparatus using a thin, toroidally bent single crystal, which could be set to reflect one or the other of the two polarization components in the scattered x-ray beam. Resonant x-ray scattering measurements were also carried out on interfaces and the charge density wave in high temperature superconducting materials.

  3. X-ray lithography source (SXLS) vacuum system

    International Nuclear Information System (INIS)

    Schuchman, J.C.; Aloia, J.; Hsieh, H.; Kim, T.; Pjerov, S.

    1989-01-01

    In 1988 Brookhaven National Laboratory (BNL) was awarded a contract to design and construct a compact light source for x-ray lithography. This award is part of a technology transfer-to-American-industry program. The contract is for an electron storage ring designed for 690 MeV-500 ma operations. It has a racetrack configuration with a circumference to 8.5 meters. The machine is to be constructed in two phases. Phase I (200 MeV-500ma) will primarily be for low energy injection studies and will incorporate all room temperature magnets. For Phase II the two room temperature dipole magnets will be replaced with (4T) superconducting magnets and operation will be at 690 MeV. This paper describes the vacuum system for this machine. 9 refs

  4. Digital optical correlator x-ray telescope alignment monitoring system

    Science.gov (United States)

    Lis, Tomasz; Gaskin, Jessica; Jasper, John; Gregory, Don A.

    2018-01-01

    The High-Energy Replicated Optics to Explore the Sun (HEROES) program is a balloon-borne x-ray telescope mission to observe hard x-rays (˜20 to 70 keV) from the sun and multiple astrophysical targets. The payload consists of eight mirror modules with a total of 114 optics that are mounted on a 6-m-long optical bench. Each mirror module is complemented by a high-pressure xenon gas scintillation proportional counter. Attached to the payload is a camera that acquires star fields and then matches the acquired field to star maps to determine the pointing of the optical bench. Slight misalignments between the star camera, the optical bench, and the telescope elements attached to the optical bench may occur during flight due to mechanical shifts, thermal gradients, and gravitational effects. These misalignments can result in diminished imaging and reduced photon collection efficiency. To monitor these misalignments during flight, a supplementary Bench Alignment Monitoring System (BAMS) was added to the payload. BAMS hardware comprises two cameras mounted directly to the optical bench and rings of light-emitting diodes (LEDs) mounted onto the telescope components. The LEDs in these rings are mounted in a predefined, asymmetric pattern, and their positions are tracked using an optical/digital correlator. The BAMS analysis software is a digital adaption of an optical joint transform correlator. The aim is to enhance the observational proficiency of HEROES while providing insight into the magnitude of mechanically and thermally induced misalignments during flight. Results from a preflight test of the system are reported.

  5. Probing single magnon excitations in Sr2IrO4 using O K-edge resonant inelastic x-ray scattering

    International Nuclear Information System (INIS)

    Liu, X; Ding, H; Dean, M P M; Yin, W G; Hill, J P; Liu, J; Ramesh, R; Chiuzbăian, S G; Jaouen, N; Nicolaou, A; Serrao, C Rayan

    2015-01-01

    Resonant inelastic x-ray scattering (RIXS) at the L-edge of transition metal elements is now commonly used to probe single magnon excitations. Here we show that single magnon excitations can also be measured with RIXS at the K-edge of the surrounding ligand atoms when the center heavy metal elements have strong spin–orbit coupling. This is demonstrated with oxygen K-edge RIXS experiments on the perovskite Sr 2 IrO 4 , where low energy peaks from single magnon excitations were observed. This new application of RIXS has excellent potential to be applied to a wide range of magnetic systems based on heavy elements, for which the L-edge RIXS energy resolution in the hard x-ray region is usually poor. (fast track communication)

  6. Moving-Article X-Ray Imaging System and Method for 3-D Image Generation

    Science.gov (United States)

    Fernandez, Kenneth R. (Inventor)

    2012-01-01

    An x-ray imaging system and method for a moving article are provided for an article moved along a linear direction of travel while the article is exposed to non-overlapping x-ray beams. A plurality of parallel linear sensor arrays are disposed in the x-ray beams after they pass through the article. More specifically, a first half of the plurality are disposed in a first of the x-ray beams while a second half of the plurality are disposed in a second of the x-ray beams. Each of the parallel linear sensor arrays is oriented perpendicular to the linear direction of travel. Each of the parallel linear sensor arrays in the first half is matched to a corresponding one of the parallel linear sensor arrays in the second half in terms of an angular position in the first of the x-ray beams and the second of the x-ray beams, respectively.

  7. RAMI analysis for ITER radial X-ray camera system

    Energy Technology Data Exchange (ETDEWEB)

    Qin, Shijun, E-mail: sjqin@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Hu, Liqun; Chen, Kaiyun [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Barnsley, Robin; Sirinelli, Antoine [ITER Organization, Route Vinon sur Verdon, CS 90046, 13067, St. Paul lez Durance, Cedex (France); Song, Yuntao; Lu, Kun; Yao, Damao; Chen, Yebin; Li, Shi; Cao, Hongrui; Yu, Hong; Sheng, Xiuli [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-11-15

    Highlights: • The functional analysis of the ITER RXC system was performed. • A failure modes, effects and criticality analysis of the ITER RXC system was performed. • The reliability and availability of the ITER RXC system and its main functions were calculated. • The ITER RAMI approach was applied to the ITER RXC system for technical risk control in the preliminary design phase. - Abstract: ITER is the first international experimental nuclear fusion device. In the project, the RAMI approach (reliability, availability, maintainability and inspectability) has been adopted for technical risk control to mitigate all the possible failure of components in preparation for operation and maintenance. RAMI analysis of the ITER Radial X-ray Camera diagnostic (RXC) system during preliminary design phase was required, which insures the system with a very high performance to measure the X-ray emission and research the MHD of plasma with high accuracy on the ITER machine. A functional breakdown was prepared in a bottom-up approach, resulting in the system being divided into 3 main functions, 6 intermediate functions and 28 basic functions which are described using the IDEFØ method. Reliability block diagrams (RBDs) were prepared to calculate the reliability and availability of each function under assumption of operating conditions and failure data. Initial and expected scenarios were analyzed to define risk-mitigation actions. The initial availability of RXC system was 92.93%, while after optimization the expected availability was 95.23% over 11,520 h (approx. 16 months) which corresponds to ITER typical operation cycle. A Failure Modes, Effects and Criticality Analysis (FMECA) was performed to the system initial risk. Criticality charts highlight the risks of the different failure modes with regard to the probability of their occurrence and impact on operations. There are 28 risks for the initial state, including 8 major risks. No major risk remains after taking into

  8. A development of laser-plasma-based soft x-ray microscope system

    International Nuclear Information System (INIS)

    Nam, Ki Yong; Kim, Kyong Woo; Kim, Kyu Gyeom; Kwon, Young Man; Yoon, Kwon Ha

    2003-01-01

    Soft x-ray nano-imaging microscopy system for biomedical application with a high resolution about 50 nm has been designed and described, and its integrated techniques also have been studied. The system is mainly composed of soft x-ray generation system, nano-scaled control system, x-ray optical device like a condenser or object mirror, a CCD camera coupled with multichannel plate (MCP) and vacuum system. In the system, soft x-ray is generated from the laser-based plasma by focusing Nd:YAG laser beam on tantalum (Ta) target. In an x-ray optical system, a wolter mirror has been considering condensing the x-ray beam on a biological specimen and zone plate was adapted as an object mirror. A Si 3 N 4 was used as specimen holder for keeping a biological sample alive in atmosphere conditions. A back-illuminated-CCD camera coupled with multichannel plate was determined to set up.

  9. Portable flash X-ray systems: applications and techniques

    International Nuclear Information System (INIS)

    Bryant, L.E.

    1976-01-01

    Three portable flash x-ray equipments are described, and applications such as jet and high explosive studies, bullet impact and lead casting experiments are given as well as techniques for triggering and protection of equipment and film

  10. X-ray fluorescence analysis of Fe - Ni - Mo systems

    International Nuclear Information System (INIS)

    Belyaev, E.E.; Ershov, A.V.; Mashin, A.I.; Mashin, N.I.; Rudnevskij, N.K.

    1998-01-01

    Procedures for the X-ray fluorescence determination of the composition and thickness of Fe - Ni - Mo thin films and the concentration of elements in thick films of the Fe - Ni - Mo alloy are developed [ru

  11. Abreu system - A dosimetric system to evaluate basic parameters of photofluorographic X-ray machine

    International Nuclear Information System (INIS)

    Feital, J.C.

    1987-01-01

    In Brazil, photofluorographic X-ray machines are used for cuberculosis mass screening throughout the country. The exact number of these X-ray equipment is unknown but it is estimated to be around 1000 operating units. Twelve million miniature chest radiographs are taken per year. In order to make local inspections speedier and also aiming at its postal use, a system has been developed wich evaluates the entrace exposure of the patient, the X-ray beam half-value layer ( leading to the evaluation of the tube's total filtration ) and the beam's field size. It consists of a piece of cardboard where filters, TLDs and X-ray films are inserted. So far the system has been tested in 53 X-ray machines in Rio de Janeiro. The results show that it can be used in a national survey program. (Author) [pt

  12. The Soft X-ray real time fast trigger system

    International Nuclear Information System (INIS)

    Blackler, K.; Edwards, A.; Holm, J.

    1992-05-01

    Most current diagnostics are limited to recording data either at fixed times and data rates, or in response to certain predefined events - such as the injection of a pellet. The previous Soft X-Ray trigger system at Joint European Torus Joint Undertaking (JET)(A.W. Edwards et al., Rev Sci Instrum. 57(8), p2142, 1986) improved upon this by using Analogue Signal Processors to monitor the analogue data in real time and to provide 'triggers' to the data acquisition system in response to an event such as a sawtooth collapse. This system was however limited in the type of events that could be detected. It was also incapable of being rapidly re-configured. Advances in digital electronics caused a study to be undertaken to see if this situation could be improved. The system described below is the result of this study and has successfully run at JET since the summer of 1990, providing a greatly increased quality of data as well as recording some new phenomena such as the spontaneous snake. This note has been produced to describe the function and operation of the trigger system. (author)

  13. The Chandra X-ray Observatory data processing system

    Science.gov (United States)

    Evans, Ian; Cresitello-Dittmar, Mark; Doe, Stephen; Evans, Janet; Fabbiano, Giuseppina; Germain, Gregg; Glotfelty, Kenny; Plummer, David; Zografou, Panagoula

    2006-06-01

    Raw data from the Chandra X-ray Observatory are processed by a set of standard data processing pipelines to create scientifically useful data products appropriate for further analysis by end users. Fully automated pipelines read the dumped raw telemetry byte stream from the spacecraft and perform the common reductions and calibrations necessary to remove spacecraft and instrumental signatures and convert the data into physically meaningful quantities that can be further analyzed by observers. The resulting data products are subject to automated validation to ensure correct pipeline processing and verify that the spacecraft configuration and scheduling matched the observers request and any constraints. In addition, pipeline processing monitors science and engineering data for anomalous indications and trending, and triggers alerts if appropriate. Data products are ingested and stored in the Chandra Data Archive, where they are made available for downloading by users. In this paper, we describe the architecture of the data processing system, including the scientific algorithms that are applied to the data, and interfaces to other subsystems. We place particular emphasis on the impacts of design choices on system integrity and maintainability. We review areas where algorithmic improvements or changes in instrument characteristics have required significant enhancements, and the mechanisms used to effect these changes while assuring continued scientific integrity and robustness. We discuss major enhancements to the data processing system that are currently being developed to automate production of the Chandra Source Catalog.

  14. Electronic zooming TV readout system for an x-ray microscope

    International Nuclear Information System (INIS)

    Kinoshita, K.; Matsumura, T.; Inagaki, Y.; Hirai, N.; Sugiyama, M.; Kihara, H.; Watanabe, N.; Shimanuki, Y.

    1993-01-01

    The electronic zooming TV readout system using the X-ray zooming tube has been developed for purposes of real-time readout of very high resolution X-ray image, e.g. the output image from an X-ray microscope. The system limiting resolution is 0.2∼0.3 μm and it is easy to operate in practical applications

  15. Control of the Low-energy X-rays by Using MCNP5 and Numerical Analysis for a New Concept Intra-oral X-ray Imaging System

    Science.gov (United States)

    Huh, Jangyong; Ji, Yunseo; Lee, Rena

    2018-05-01

    An X-ray control algorithm to modulate the X-ray intensity distribution over the FOV (field of view) has been developed by using numerical analysis and MCNP5, a particle transport simulation code on the basis of the Monte Carlo method. X-rays, which are widely used in medical diagnostic imaging, should be controlled in order to maximize the performance of the X-ray imaging system. However, transporting X-rays, like a liquid or a gas is conveyed through a physical form such as pipes, is not possible. In the present study, an X-ray control algorithm and technique to uniformize the Xray intensity projected on the image sensor were developed using a flattening filter and a collimator in order to alleviate the anisotropy of the distribution of X-rays due to intrinsic features of the X-ray generator. The proposed method, which is combined with MCNP5 modeling and numerical analysis, aimed to optimize a flattening filter and a collimator for a uniform distribution of X-rays. Their size and shape were estimated from the method. The simulation and the experimental results both showed that the method yielded an intensity distribution over an X-ray field of 6×4 cm2 at SID (source to image-receptor distance) of 5 cm with a uniformity of more than 90% when the flattening filter and the collimator were mounted on the system. The proposed algorithm and technique are not only confined to flattening filter development but can also be applied for other X-ray related research and development efforts.

  16. Radiation safety for baggage x-ray inspection systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-05-01

    This book is an outgrowth of a course on radiation safety aimed at technicians responsible for conducting maintenance on baggage x-ray inspection systems used in federally operated facilities. The need for a single reference book became apparent to the instructor in 1984. In an effort to provide a cohesive development of the subject, a set of lecture notes was prepared and revised annually since 1984, from which this book has evolved. This book is intended to present concepts necessary for an elementary but comprehensive knowledge of radiation safety. While some material coverage may appear somewhat detailed, it is a deliberate attempt to strengthen areas of demonstrated weaknesses observed in course attenders and to provide guidance on the numerous questions about man-made radiation asked by course attenders over the years. Numerical examples are included in most chapters for clarity and ease of understanding. The problems given at the end of most chapters provide the reader with the opportunity of applying the material presented in the chapters to situations of practical interest. It is important that these problems be considered an integral part of the course and students attempt to solve them. 36 refs., 9 tabs., 17 figs.

  17. Optical Synchronization Systems for Femtosecond X-raySources

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, Russell; Staples, John W.; Holzwarth, Ronald

    2004-05-09

    In femtosecond pump/probe experiments using short X-Ray and optical pulses, precise synchronization must be maintained between widely separated lasers in a synchrotron or FEL facility. We are developing synchronization systems using optical signals for applications requiring different ranges of timing error over 100 meter of glass fiber. For stabilization in the hundred femtosecond range a CW laser is amplitude modulated at 1 10 GHz, the signal retroreflected from the far end, and the relative phase used to correct the transit time with a piezoelectric phase modulator. For the sub-10 fsec range the laser frequency itself is upshifted 55 MHz with an acousto-optical modulator, retroreflected, upshifted again and phase compared at the sending end to a 110 MHz reference. Initial experiments indicate less than 1 fsec timing jitter. To lock lasers in the sub-10 fs range we will lock two single-frequency lasers separated by several tera Hertz to a master modelocked fiber laser, transmit the two frequencies over fiber, and lock two comb lines of a slave laser to these frequencies, thus synchronizing the two modelocked laser envelopes.

  18. Optical Synchronization Systems for Femtosecond X-Ray Sources

    CERN Document Server

    Wilcox, Russell; Staples, John W

    2005-01-01

    In femtosecond pump/probe experiments using short x-ray and optical pulses, precise synchronization must be maintained between widely separated lasers in a synchrotron or FEL facility. We are developing synchronization systems using optical signals for applications requiring different ranges of timing error. For the sub-100fs range we use an amplitude modulated CW laser at 1GHz to transmit RF phase information, and control the delay through a 100m fiber by observing the retroreflected signal. Initial results show 40fs peak-to-peak error above 10Hz, and 200fs long term drift, mainly due to amplitude sensitivity in the analog mixers. For the sub-10fs range we will lock two single-frequency lasers separated by several teraHertz to a master modelocked fiber laser, transmit the two frequencies over fiber, and lock two comb lines of a slave laser to these frequencies, thus synchronizing the two modelocked laser envelopes. For attosecond synchronization we propose a stabilized, free space link using bulk lens wavegu...

  19. Radiation safety for baggage x-ray inspection systems

    International Nuclear Information System (INIS)

    1994-05-01

    This book is an outgrowth of a course on radiation safety aimed at technicians responsible for conducting maintenance on baggage x-ray inspection systems used in federally operated facilities. The need for a single reference book became apparent to the instructor in 1984. In an effort to provide a cohesive development of the subject, a set of lecture notes was prepared and revised annually since 1984, from which this book has evolved. This book is intended to present concepts necessary for an elementary but comprehensive knowledge of radiation safety. While some material coverage may appear somewhat detailed, it is a deliberate attempt to strengthen areas of demonstrated weaknesses observed in course attenders and to provide guidance on the numerous questions about man-made radiation asked by course attenders over the years. Numerical examples are included in most chapters for clarity and ease of understanding. The problems given at the end of most chapters provide the reader with the opportunity of applying the material presented in the chapters to situations of practical interest. It is important that these problems be considered an integral part of the course and students attempt to solve them. 36 refs., 9 tabs., 17 figs

  20. Optical Synchronization Systems for Femtosecond X-ray Sources

    International Nuclear Information System (INIS)

    Wilcox, Russell; Staples, John W.; Holzwarth, Ronald

    2004-01-01

    In femtosecond pump/probe experiments using short X-Ray and optical pulses, precise synchronization must be maintained between widely separated lasers in a synchrotron or FEL facility. We are developing synchronization systems using optical signals for applications requiring different ranges of timing error over 100 meter of glass fiber. For stabilization in the hundred femtosecond range a CW laser is amplitude modulated at 1 10 GHz, the signal retroreflected from the far end, and the relative phase used to correct the transit time with a piezoelectric phase modulator. For the sub-10 fsec range the laser frequency itself is upshifted 55 MHz with an acousto-optical modulator, retroreflected, upshifted again and phase compared at the sending end to a 110 MHz reference. Initial experiments indicate less than 1 fsec timing jitter. To lock lasers in the sub-10 fs range we will lock two single-frequency lasers separated by several tera Hertz to a master modelocked fiber laser, transmit the two frequencies over fiber, and lock two comb lines of a slave laser to these frequencies, thus synchronizing the two modelocked laser envelopes

  1. Development of a micro-X-ray fluorescence system based on polycapillary X-ray optics for non-destructive analysis of archaeological objects

    Science.gov (United States)

    Cheng, Lin; Ding, Xunliang; Liu, Zhiguo; Pan, Qiuli; Chu, Xuelian

    2007-08-01

    A new micro-X-ray fluorescence (micro-XRF) system based on rotating anode X-ray generator and polycapillary X-ray optics has been set up in XOL Lab, BNU, China, in order to be used for analysis of archaeological objects. The polycapillary X-ray optics used here can focus the primary X-ray beam down to tens of micrometers in diameter that allows for non-destructive and local analysis of sub-mm samples with minor/trace level sensitivity. The analytical characteristics and potential of this micro-XRF system in archaeological research are discussed. Some described uses of this instrument include studying Chinese ancient porcelain.

  2. Development of a micro-X-ray fluorescence system based on polycapillary X-ray optics for non-destructive analysis of archaeological objects

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Lin [Key Laboratory of Beam Technology and Material Modification of Ministry of Education, Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing Radiation Center, Beijing, 100875 (China)], E-mail: chenglin@bnu.edu.cn; Ding Xunliang; Liu Zhiguo; Pan Qiuli; Chu Xuelian [Key Laboratory of Beam Technology and Material Modification of Ministry of Education, Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing Radiation Center, Beijing, 100875 (China)

    2007-08-15

    A new micro-X-ray fluorescence (micro-XRF) system based on rotating anode X-ray generator and polycapillary X-ray optics has been set up in XOL Lab, BNU, China, in order to be used for analysis of archaeological objects. The polycapillary X-ray optics used here can focus the primary X-ray beam down to tens of micrometers in diameter that allows for non-destructive and local analysis of sub-mm samples with minor/trace level sensitivity. The analytical characteristics and potential of this micro-XRF system in archaeological research are discussed. Some described uses of this instrument include studying Chinese ancient porcelain.

  3. Synthesis, structural, X-ray photoelectron spectroscopy (XPS) studies and IR induced anisotropy of Tl{sub 4}HgI{sub 6} single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Parasyuk, O.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, Voli Ave. 13, Lutsk, 43025 (Ukraine); Khyzhun, O.Y. [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky St., 03142, Kyiv (Ukraine); Piasecki, M. [Institute of Physics, J. Dlugosz University Częstochowa, Armii Krajowej 13/15, Częstochowa (Poland); Kityk, I.V., E-mail: iwank74@gmail.com [Electrical Engineering Department, Czestochowa University Technology, Armii Krajowej 17, PL-42-217, Czestochowa (Poland); Lakshminarayana, G. [Wireless and Photonic Networks Research Centre, Faculty of Engineering, Universiti Putra Malaysia, 43400, Serdang, Selangor (Malaysia); Luzhnyi, I. [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky St., 03142, Kyiv (Ukraine); Fochuk, P.M. [Yuriy Fed’kovych Chernivtsi National University, 2 Kotziubynskoho Str., 58012, Chernivtsi (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, Pekarska Street 50, 79010, Lviv (Ukraine); Levkovets, S.I.; Yurchenko, O.M.; Piskach, L.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, Voli Ave. 13, Lutsk, 43025 (Ukraine)

    2017-02-01

    In the present work, we report on the synthesis and structural properties including X-ray protoelectron spectroscopy (XPS) analysis of Tl{sub 4}HgI{sub 6} crystals that were grown by Bridgman-Stockbarger method up to 80 mm in length and 18 mm in diameter. The existence of the ternary compound Tl{sub 4}HgI{sub 6} that melts incongruently at 641 K was confirmed. Phase equilibria and structural properties for the TlI–HgI{sub 2} system were investigated by differential thermal analysis (DTA) and X-ray diffraction (XRD) methods. X-ray photoelectron spectra were measured for both pristine and Ar{sup +} ion-bombarded Tl{sub 4}HgI{sub 6} single crystal surfaces. The data reveal that the Tl{sub 4}HgI{sub 6} single crystal is sensitive with respect to Ar{sup +} ion-bombardment as 3.0 keV Ar{sup +} irradiation over 5 min at an ion current density 14 μA/cm{sup 2} induces changes to the elemental stoichiometry of the Tl{sub 4}HgI{sub 6} surface, leading to a decrease of the mercury content in the topmost surface layers. X-ray photoelectron spectroscopy (XPS) measurements indicate very low hygroscopic nature of the Tl{sub 4}HgI{sub 6} single crystal surface. The IR coherent bicolor laser treatment at wavelengths 10.6/5.3 μm has shown an occurrence of anisotropy at wavelengths 1540 nm of Er:glass laser. This may open the applications of Tl{sub 4}HgI{sub 6} as a material for IR laser triggering. - Highlights: • Phase diagram of the HgI{sub 2}–TlI system was built. • Tl{sub 4}HgI{sub 6} single crystals were grown by Bridgman Stockbarger method. • XRD, XPS analysis was done. • Ir induced anisotropy was established. • The compounds may be proposed as Ir laser operated polarizers.

  4. 21 CFR 892.1630 - Electrostatic x-ray imaging system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. An electrostatic x-ray imaging system is a device intended for medical... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrostatic x-ray imaging system. 892.1630... visible image. This generic type of device may include signal analysis and display equipment, patient and...

  5. Portable pulsed X-ray digital radiographic system based on network transmission

    International Nuclear Information System (INIS)

    Tang Le; Li Yuanjing; Wang Yi; Cheng Jianping

    2004-01-01

    Network communication technology of TCP/IP protocol serves as application in pulse X-ray digital radiography system. The system radiographs synchronously with pulse X-ray and converts image signals to digital data, which are transmitted to computer for displaying and processing in network. The system composing structures are present and portable and other characteristics are introduced. (authors)

  6. Tumour-cell killing by X-rays and immunity quantitated in a mouse model system

    International Nuclear Information System (INIS)

    Porteous, D.D.; Porteous, K.M.; Hughes, M.J.

    1979-01-01

    As part of an investigation of the interaction of X-rays and immune cytotoxicity in tumour control, an experimental mouse model system has been used in which quantitative anti-tumour immunity was raised in prospective recipients of tumour-cell suspensions exposed to varying doses of X-rays in vitro before injection. Findings reported here indicate that, whilst X-rays kill a proportion of cells, induced immunity deals with a fixed number dependent upon the immune status of the host, and that X-rays and anti-tumour immunity do not act synergistically in tumour-cell killing. The tumour used was the ascites sarcoma BP8. (author)

  7. Magnetic resonance imaging of the central nervous system. Comparison with X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Kajima, Toshio; Kagawa, Yoshihiro; Katsuta, Shizutomo.

    1987-06-01

    Magnetic resonance imaging (MRI) and X-ray computed tomography (X-ray CT) have been performed in 169 consecutive patients with central nervous system diseases. The findings from the two methods were compared for the capacity to defect lesions. Magnetic resonance imaging was more sensitive than or equivalent to X-ray CT in detecting lesions - especially detecting. Arnold-Chiari malformation, syringomyelia, spinal cord injury, and pituitary adenoma - in 158 patients (94 %). In six patients (10 %), lesion detection was possible only by MRI. Magnetic resonance imaging was inferior to X-ray CT in 11 patients (7 %) in detecting calcified lesions, meningioma, and cavernous hemangioma. (Namekawa, K.).

  8. KD901G X-ray system to reject contaminants

    International Nuclear Information System (INIS)

    Shinohara, Hachiro

    1995-01-01

    Among the complaints to the foods that consumers bought, the proportion of the mixing of alien substances is more than 20%. The number of the cases classified by the kinds of alien substances, and that of minerals and animal substances are shown. The causes of the mixing of alien substances are classified into those due to the mixing in raw materials, production places, processing machines and workers. In case of using primary products as raw materials, the alien substances closely related to those raw materials are difficult to detect, such as bones and hairs in animal meat, fish bones, egg shells and fruit seeds. There are problems and limitation in the inspection of alien substance mixing by visual or touching inspection, metal detectors and the visual inspection of X-ray radiographs. The judgement of the presence of alien substances by automatically processing X-ray radiograph information has been tried one or two-dimensionally. The X-ray alien substance detector KD901G adopted the one-dimensional line sensor type, and its features are shown. The effective introduction of the X-ray alien substance detector, its comparison with metal detectors, and the safety of workers against radiation exposure and the safety of inspected foods are discussed. (K.I.)

  9. X-ray phase analysis in leucite systems

    Czech Academy of Sciences Publication Activity Database

    Maixner, J.; Kloužková, A.; Mrázová, M.; Kohoutková, Martina

    2007-01-01

    Roč. 26, č. 2 (2007), s. 531-536 ISSN 0044-2968 R&D Projects: GA MPO 2A-1TP1/063 Institutional research plan: CEZ:AV0Z40320502 Keywords : cubic leucite * phase transformation * X-ray powder diffraction Subject RIV: CA - Inorganic Chemistry Impact factor: 1.338, year: 2007

  10. 21 CFR 872.1800 - Extraoral source x-ray system.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1800 Extraoral source x-ray system. (a... dental radiographic examination and diagnosis of diseases of the teeth, jaw, and oral structures. The x... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Extraoral source x-ray system. 872.1800 Section...

  11. Simultaneous analysis of Grazing Incidence X-Ray reflectivity and X-ray standing waves from periodic multilayer systems

    NARCIS (Netherlands)

    Yakunin, S.N.; Makhotkin, Igor Alexandrovich; Chuyev, M.A.; Seregin, A.Y.; Pashayev, E.M.; Louis, Eric; van de Kruijs, Robbert Wilhelmus Elisabeth; Bijkerk, Frederik; Kovalchuk, M.V.

    2012-01-01

    Structural analysis of periodic multilayers with small period thickness (~4 nm) is a challenging task, especially when thicknesses of intermixed interfaces become comparable to individual layer thicknesses. In general, angular dependent X-ray fluorescence measurements, excited by the X-ray standing

  12. Software System for the Calibration of X-Ray Measuring Instruments

    International Nuclear Information System (INIS)

    Gaytan-Gallardo, E.; Tovar-Munoz, V. M.; Cruz-Estrada, P.; Vergara-Martinez, F. J.; Rivero-Gutierrez, T.

    2006-01-01

    A software system that facilities the calibration of X-ray measuring instruments used in medical applications is presented. The Secondary Standard Dosimetry Laboratory (SSDL) of the Nuclear Research National Institute in Mexico (ININ in Spanish), supports activities concerning with ionizing radiations in medical area. One of these activities is the calibration of X-ray measuring instruments, in terms of air kerma or exposure by substitution method in an X-ray beam at a point where the rate has been determined by means of a standard ionization chamber. To automatize this process, a software system has been developed, the calibration system is composed by an X-ray unit, a Dynalizer IIIU X-ray meter by RADCAL, a commercial data acquisition card, the software system and the units to be tested and calibrated. A quality control plan has been applied in the development of the software system, ensuring that quality assurance procedures and standards are being followed

  13. Performance of a static-anode/flat-panel x-ray fluoroscopy system in a diagnostic strength magnetic field: a truly hybrid x-ray/MR imaging system.

    Science.gov (United States)

    Fahrig, R; Wen, Z; Ganguly, A; DeCrescenzo, G; Rowlands, J A; Stevens, G M; Saunders, R F; Pelc, N J

    2005-06-01

    Minimally invasive procedures are increasing in variety and frequency, facilitated by advances in imaging technology. Our hybrid imaging system (GE Apollo flat panel, custom Brand x-ray static anode x-ray tube, GE Lunar high-frequency power supply and 0.5 T Signa SP) provides both x-ray and MR imaging capability to guide complex procedures without requiring motion of the patient between two distant gantries. The performance of the x-ray tube in this closely integrated system was evaluated by modeling and measuring both the response of the filament to an externally applied field and the behavior of the electron beam for field strengths and geometries of interest. The performance of the detector was assessed by measuring the slanted-edge modulation transfer function (MTF) and when placed at zero field and at 0.5 T. Measured resonant frequencies of filaments can be approximated using a modified vibrating beam model, and were at frequencies well below the 25 kHz frequency of our generator for our filament geometry. The amplitude of vibration was not sufficient to cause shorting of the filament during operation within the magnetic field. A simple model of electrons in uniform electric and magnetic fields can be used to estimate the deflection of the electron beam on the anode for the fields of interest between 0.2 and 0.5 T. The MTF measured at the detector and the DQE showed no significant difference inside and outside of the magnetic field. With the proper modifications, an x-ray system can be fully integrated with a MR system, with minimal loss of image quality. Any x-ray tube can be assessed for compatibility when placed at a particular location within the field using the models. We have also concluded that a-Si electronics are robust against magnetic fields. Detailed knowledge of the x-ray system installation is required to provide estimates of system operation.

  14. Performance of a static-anode/flat-panel x-ray fluoroscopy system in a diagnostic strength magnetic field: A truly hybrid x-ray/MR imaging system

    International Nuclear Information System (INIS)

    Fahrig, R.; Wen, Z.; Ganguly, A.; DeCrescenzo, G.; Rowlands, J.A.; Stevens, G.M.; Saunders, R.F.; Pelc, N.J.

    2005-01-01

    Minimally invasive procedures are increasing in variety and frequency, facilitated by advances in imaging technology. Our hybrid imaging system (GE Apollo TM flat panel, custom Brand x-ray static anode x-ray tube, GE Lunar high-frequency power supply and 0.5 T Signa SP TM ) provides both x-ray and MR imaging capability to guide complex procedures without requiring motion of the patient between two distant gantries. The performance of the x-ray tube in this closely integrated system was evaluated by modeling and measuring both the response of the filament to an externally applied field and the behavior of the electron beam for field strengths and geometries of interest. The performance of the detector was assessed by measuring the slanted-edge modulation transfer function (MTF) and when placed at zero field and at 0.5 T. Measured resonant frequencies of filaments can be approximated using a modified vibrating beam model, and were at frequencies well below the 25 kHz frequency of our generator for our filament geometry. The amplitude of vibration was not sufficient to cause shorting of the filament during operation within the magnetic field. A simple model of electrons in uniform electric and magnetic fields can be used to estimate the deflection of the electron beam on the anode for the fields of interest between 0.2 and 0.5 T. The MTF measured at the detector and the DQE showed no significant difference inside and outside of the magnetic field. With the proper modifications, an x-ray system can be fully integrated with a MR system, with minimal loss of image quality. Any x-ray tube can be assessed for compatibility when placed at a particular location within the field using the models. We have also concluded that a-Si electronics are robust against magnetic fields. Detailed knowledge of the x-ray system installation is required to provide estimates of system operation

  15. Mass loss from OB supergiants in x-ray binary systems

    International Nuclear Information System (INIS)

    Alme, M.L.; Wilson, J.R.

    1975-01-01

    A study of the atmospheres of OB supergiants in x-ray binary systems indicates that when the stellar surface is close enough to the saddle in the gravitational potential to provide a mass transfer rate adequate to power a compact x-ray source, large-amplitude variations in the rate of mass flow occur. 9 references

  16. Microprocessor-based system for automatic X-ray diffraction and fluorescence

    International Nuclear Information System (INIS)

    Souza, A.M. de; Carmo, L.C.S. do; Pereira, V.J.E.; Soares, E.A.

    1984-01-01

    A data acquisition and processing device appropriate for X-ray analysis and goniometer control was built. The Z-80 based system as well as the whole architeture is described. The advantages and new possibilities of the automated instrument as compared to the traditional ones are listed. The X-ray diffraction and fluorescence techniques can take advantage of the automation. (Author) [pt

  17. Human engineering design in medical x-ray system

    International Nuclear Information System (INIS)

    Mori, Sadayoshi

    1981-01-01

    The dimension of control desk, design of controller and indicator are studied in relation with human body dimension of radiological technologist. First, in the design of apparatus, it is reasonable to adopt the cumulative distribution in stead of mean values of human body dimension because the mean values would be cause of inadequacy to the majority of operator. Second, I reported about the fundamental items e.g. the display of controller and indicator recommended from the point of view of human engineering. Up to now the radiological technologists were intended to take a serious view of performance of X-ray apparatus only, but hereafter, we think, it is also important to induce the thought of human engineering in the design of X-ray apparatus. (J.P.N.)

  18. Safety Study of the X-Ray Reference Laboratory for Radiation Protection Levels (IR-14D)

    International Nuclear Information System (INIS)

    Garcia, G.

    1999-01-01

    This report is a study about the safety of the X-ray reference laboratory that has been recently constructed in the building 2 of the CIEMAT. After a brief description of the apparatus, we present the method used to calculate the exposure and absorbed dose rates in the most characteristic points of the laboratory. This method takes into account the spectral distribution of the radiation beams as a function of the accelerating voltage. The built-up factors of the absorbent materials have been considered to calculate the transmission of the radiation beams through the filters and shielding. Scattered radiations has been introduced in the calculations by means of a semiempirical method. This model supposes that multiple scattering processes give an isotropic contribution to the reflected beams and the single scattered can be described in terms of the differential cross section of Klein-Nishina. The results of this study have been applied to determine the maximum dose equivalent that the personnel of the laboratory could receive in normal operation conditions. (Author) 5 refs

  19. Ultra-high vacuum compatible optical chopper system for synchrotron x-ray scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hao, E-mail: hc000211@ohio.edu [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Nanoscale and Quantum Phenomena Institute, Physics & Astronomy Department, Ohio University, Athens, Ohio 45701 (United States); Cummings, Marvin; Shirato, Nozomi; Stripe, Benjamin; Preissner, Curt; Freeland, John W. [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Rosenmann, Daniel [Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Kersell, Heath; Hla, Saw-Wai [Nanoscale and Quantum Phenomena Institute, Physics & Astronomy Department, Ohio University, Athens, Ohio 45701 (United States); Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Rose, Volker, E-mail: vrose@anl.gov [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States)

    2016-01-28

    High-speed beam choppers are a crucial part of time-resolved x-ray studies as well as a necessary component to enable elemental contrast in synchrotron x-ray scanning tunneling microscopy (SX-STM). However, many chopper systems are not capable of operation in vacuum, which restricts their application to x-ray studies with high photon energies, where air absorption does not present a significant problem. To overcome this limitation, we present a fully ultra-high vacuum (UHV) compatible chopper system capable of operating at variable chopping frequencies up to 4 kHz. The lightweight aluminum chopper disk is coated with Ti and Au films to provide the required beam attenuation for soft and hard x-rays with photon energies up to about 12 keV. The chopper is used for lock-in detection of x-ray enhanced signals in SX-STM.

  20. System for automatic x-ray-image analysis, measurement, and sorting of laser fusion targets

    International Nuclear Information System (INIS)

    Singleton, R.M.; Perkins, D.E.; Willenborg, D.L.

    1980-01-01

    This paper describes the Automatic X-Ray Image Analysis and Sorting (AXIAS) system which is designed to analyze and measure x-ray images of opaque hollow microspheres used as laser fusion targets. The x-ray images are first recorded on a high resolution film plate. The AXIAS system then digitizes and processes the images to accurately measure the target parameters and defects. The primary goals of the AXIAS system are: to provide extremely accurate and rapid measurements, to engineer a practical system for a routine production environment and to furnish the capability of automatically measuring an array of images for sorting and selection

  1. Methods for X-ray examinations of the maxillodental system

    International Nuclear Information System (INIS)

    Rabukhina, N.A.; Arzhantsev, A.P.

    1992-01-01

    Only two roentgenography methods (periapical and occlusion) are used for production of dental roentgenograms. Periapical survey must be used only for revealing state of bone tissue around tooth root tops. In parodontology it is necessary to use occlusion survey. Perfection of the methods and improvement of quality of tooth roentgenograpms demand to change the design of native dental X-ray unit: elongation of its tube, increase of radiator power. Introduction of orthopantomography as basis method of roengenography in stomatology is the most radical decision of methodological problems. Orthopantomography is replaced by intra- and extra-oral roentgenography of teeth and jaws

  2. Hard X-Ray PHA System on the HT-7 Tokamak

    International Nuclear Information System (INIS)

    Lin Shiyao; Shi Yuejiang; Wan Baonian; Chen Zhongyong; Hu Liqun

    2006-01-01

    A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes

  3. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  4. Design, development and integration of a large scale multiple source X-ray computed tomography system

    International Nuclear Information System (INIS)

    Malcolm, Andrew A.; Liu, Tong; Ng, Ivan Kee Beng; Teng, Wei Yuen; Yap, Tsi Tung; Wan, Siew Ping; Kong, Chun Jeng

    2013-01-01

    X-ray Computed Tomography (CT) allows visualisation of the physical structures in the interior of an object without physically opening or cutting it. This technology supports a wide range of applications in the non-destructive testing, failure analysis or performance evaluation of industrial products and components. Of the numerous factors that influence the performance characteristics of an X-ray CT system the energy level in the X-ray spectrum to be used is one of the most significant. The ability of the X-ray beam to penetrate a given thickness of a specific material is directly related to the maximum available energy level in the beam. Higher energy levels allow penetration of thicker components made of more dense materials. In response to local industry demand and in support of on-going research activity in the area of 3D X-ray imaging for industrial inspection the Singapore Institute of Manufacturing Technology (SIMTech) engaged in the design, development and integration of large scale multiple source X-ray computed tomography system based on X-ray sources operating at higher energies than previously available in the Institute. The system consists of a large area direct digital X-ray detector (410 x 410 mm), a multiple-axis manipulator system, a 225 kV open tube microfocus X-ray source and a 450 kV closed tube millifocus X-ray source. The 225 kV X-ray source can be operated in either transmission or reflection mode. The body of the 6-axis manipulator system is fabricated from heavy-duty steel onto which high precision linear and rotary motors have been mounted in order to achieve high accuracy, stability and repeatability. A source-detector distance of up to 2.5 m can be achieved. The system is controlled by a proprietary X-ray CT operating system developed by SIMTech. The system currently can accommodate samples up to 0.5 x 0.5 x 0.5 m in size with weight up to 50 kg. These specifications will be increased to 1.0 x 1.0 x 1.0 m and 100 kg in future

  5. Closed-bore XMR (CBXMR) systems for aortic valve replacement: X-ray tube imaging performance

    International Nuclear Information System (INIS)

    Bracken, John A.; Komljenovic, Philip; Lillaney, Prasheel V.; Fahrig, Rebecca; Rowlands, J. A.

    2009-01-01

    A hybrid closed-bore x-ray/MRI system (CBXMR) is proposed to improve the safety and efficacy of percutaneous aortic valve replacement procedures. In this system, an x-ray C-arm will be positioned about 1 m from the entrance of a 1.5 T MRI scanner. The CBXMR system will harness the complementary strengths of both modalities to guide and deploy a bioprosthetic valve into the aortic annulus of the heart without coronary artery obstruction. A major challenge in constructing this system is ensuring proper operation of a rotating-anode x-ray tube in the MRI magnetic fringe field environment. The electron beam in the x-ray tube responsible for producing x rays can be deflected by the fringe field. However, the clinical impact of electron beam deflection in a magnetic field has not yet been studied. Here, the authors investigated changes in focal spot resolving power, field of view shift, and field of view truncation in x-ray images as a result of electron beam deflection. The authors found that in the fringe field acting on the x-ray tube at the clinical location for the x-ray C-arm (4 mT), focal spot size increased by only 2%, so the fringe field did not limit the resolving power of the x-ray system. The magnetic field also caused the field of view to shift by 3 mm. This shift must be corrected to avoid unnecessary primary radiation exposure to the patient and the staff in the cardiac catheterization laboratory. The fringe field was too weak to cause field of view truncation.

  6. Directional x-ray dark-field imaging of strongly ordered systems

    Science.gov (United States)

    Jensen, Torben Haugaard; Bech, Martin; Zanette, Irene; Weitkamp, Timm; David, Christian; Deyhle, Hans; Rutishauser, Simon; Reznikova, Elena; Mohr, Jürgen; Feidenhans'L, Robert; Pfeiffer, Franz

    2010-12-01

    Recently a novel grating based x-ray imaging approach called directional x-ray dark-field imaging was introduced. Directional x-ray dark-field imaging yields information about the local texture of structures smaller than the pixel size of the imaging system. In this work we extend the theoretical description and data processing schemes for directional dark-field imaging to strongly scattering systems, which could not be described previously. We develop a simple scattering model to account for these recent observations and subsequently demonstrate the model using experimental data. The experimental data includes directional dark-field images of polypropylene fibers and a human tooth slice.

  7. Optimum power of radiation dose in X ray television systems of flaw inspection in industry

    International Nuclear Information System (INIS)

    Denbnovetskii, S.V.; Troitskii, V.A.; Belyi, N.G.; Grom, V.S.; Kuz'micheva, N.V.; Leshchishin, A.V.; Mikhailov, V.N.; Shutenko, O.V.

    1990-01-01

    The authors present the experimental dose characteristics of a x ray television system based on x ray vidicons with the diameter of the working field of 900 mm which operate in the continuous and pulsed conditions with the longer time of cumulation of radiation images on the target of the x ray vidicon. For each type of the inspected material, its thickness, and cumulation time, the dose characteristics were used to determine the optimum power of the exposure dose ensuring the maximum signal/noise ratio and detectability of the defects at the output of the system. (author)

  8. Neutron and X-ray Tomography (NeXT) system for simultaneous, dual modality tomography

    Science.gov (United States)

    LaManna, J. M.; Hussey, D. S.; Baltic, E.; Jacobson, D. L.

    2017-11-01

    Dual mode tomography using neutrons and X-rays offers the potential of improved estimation of the composition of a sample from the complementary interaction of the two probes with the sample. We have developed a simultaneous neutron and 90 keV X-ray tomography system that is well suited to the study of porous media systems such as fuel cells, concrete, unconventional reservoir geologies, limestones, and other geological media. We present the characteristic performance of both the neutron and X-ray modalities. We illustrate the use of the simultaneous acquisition through improved phase identification in a concrete core.

  9. Control system of digital x-ray systems by quality parameters

    International Nuclear Information System (INIS)

    Balashov, S.V.; Kovalenko, Yu.N.

    2013-01-01

    The paper proposed a control system of X-ray digital equipment on quality indicators. Two basic parameters were determined: image quality and patients' radiation load. A method for monitoring these indicators is proposed. The criterion of equipment suitability is to obtain control digital X-ray images of diagnostically acceptable quality at a fixed low entrance dose in the plane of the digital detector. It is shown that the control system of X-ray digital equipment based on indicators of quality is the most appropriate in situations of deficit of financial resources, since minimizing the costs for the purchase and running of control systems, does not require highly skilled technical personnel, and reduces the duration of the equipment inspection. (authors)

  10. Mirrors for High Resolution X-Ray Optics---Figure Preserving IR/PT Coating

    Science.gov (United States)

    Chan, Kai-Wing; Olsen, Lawrence; Sharpe, Marton; Numata, Ai; McClelland, Ryan; Saha, Timo; Zhang, Will

    2016-01-01

    Coating stress of 10 - 20 nm of Ir is sufficiently high to distort the figure of arc-second thin lightweight mirrors. For iridium: --Stress sigma 4 GPa for 15 nm film implies 60 Nm integrated stress-- Need less than 3 N/m (or stress less than 200 MPa) for sub-arcsecond optics. Basic Approaches for Mitigation. A. Annealing the film-- Glass can be heat up to 400 C without distortion. Silicon is even more resistant.-- It was found that recovery is limited by residual thermal stress from taking the mirror down from high T. B. Coating bi-layer films with compressive stress with tensile stress. C. Front-and-back coating with magnetron sputtering or atomic layer deposition-- Sputtering involve spanning of substrates. Geometric difference in setup (convexness/concaveness of curved mirrors) does not permit precise front-and-back matching-- Atomic layer deposition can provide a uniform deposition front and back simultaneously.

  11. Elastic properties and structural studies on some zinc-borate glasses derived from ultrasonic, FT-IR and X-ray techniques

    International Nuclear Information System (INIS)

    Gaafar, M.S.; El-Aal, N.S. Abd; Gerges, O.W.; El-Amir, G.

    2009-01-01

    Glasses in the system (1 - x) [29Na 2 O- 4Al 2 O 3 - 67B 2 O 3 ]- xZnO (0 ≤ x ≤ 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N 4 values (fraction of tetrahedral coordinated boron atoms), and substitution of longer bond lengths of Zn-O in place of shorter B-O bond. The results indicate that Zinc ions have been substituted for boron ions as tetrahedral network former ions. The elastic moduli are observed to increase with the increase of ZnO content.

  12. FT-IR X-ray diffraction and porosimetry studies of archaeologic artifacts recently excavated from Rajakkamangalam in Tamilnadu

    International Nuclear Information System (INIS)

    Babu Suresh; Velraj, Gothandapani

    2011-01-01

    In the present study, fragmented pottery sample were collected from the recently excavated archaeologic site named Rajakkamangalam, India. The samples were collected at different depths. The samples were subjected to FT-IR, X-ray diffraction and also porosimetry study was done, The spectroscopic method Fourier Transform Infrared Spectroscopy (FT-IR) has been employed to find the mineralogical composition of the potteries. And the complementary technique to find the clay minerals present using XRD. The major primary minerals present in the samples are Kaolinite and the secondary mineral present is quartz and the accessory minerals present in the sample are hematite and magnetite. In addition to the used mineral the orthoclase and orthopyroxene are present in the sample of interest. The firing temperature of the samples at the time of manufacturing is also estimated from apparent porosity of the samples. The percentage of the potteries lies in the range of porosity is 17-42 percentages. The results obtained from Porosimetry techniques on pottery shreds provide information of the firing temperature might have been fired below 1000 deg C at the time of manufacturing the potteries. (author)

  13. Effect of X-ray suppression system upon parameters of electrostatic accelerator ion beam

    Directory of Open Access Journals (Sweden)

    I. G. Ignat'ev

    2014-12-01

    Full Text Available Experimental study results are presented for a beam profile and emittance of an electrostatic accelerator “Sokol” before and after being equipped with magnet X-ray suppression system.

  14. Three-Dimensional Backscatter X-Ray Imaging System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall objective of the proposal is to design, develop and demonstrate a potentially portable Compton x-ray scatter 3D-imaging system by using specially...

  15. Constancy tests radiography X-ray devices with CR system

    International Nuclear Information System (INIS)

    Durdikova, M.; Zakova, M.

    2005-01-01

    The paper presents the changes in QAP (Quality Assurance Program) as consequence of digitalisation of medical facilities. Digitalisation brings many advantages - more comfort for personal use, images are easy achievable and transferable to workstation, fine quality images by postprocessing are easily achievable. But it must be taken into account that due to simplicity of image make it is sometimes taken more images then necessary .There are two possible ways of digitalisation in radiography: to exchange conventional developer machine by Computer Radiography (CR), that means to use CR reader and cassette with phosphor plate - un-direct digitalisation or to use special radiography X-ray devices with flat-panel detector -direct radiography. (authors)

  16. Optical synchronization system for femtosecond X-ray sources

    Science.gov (United States)

    Wilcox, Russell B [El Cerrito, CA; Holzwarth, Ronald [Munich, DE

    2011-12-13

    Femtosecond pump/probe experiments using short X-Ray and optical pulses require precise synchronization between 100 meter-10 km separated lasers in a various experiments. For stabilization in the hundred femtosecond range a CW laser is amplitude modulated at 1-10 GHz, the signal retroreflected from the far end, and the relative phase used to correct the transit time with various implementations. For the sub-10 fsec range the laser frequency itself is upshifted 55 MHz with an acousto-optical modulator, retroreflected, upshifted again and phase compared at the sending end to a 110 MHz reference. Initial experiments indicate less than 1 fsec timing jitter. To lock lasers in the sub-10 fs range two single-frequency lasers separated by several teraHertz will be lock to a master modelocked fiber laser, transmit the two frequencies over fiber, and lock two comb lines of a slave laser to these frequencies, thus synchronizing the two modelocked laser envelopes.

  17. Development of online cable eccentricity detection system based on X-ray CCD

    International Nuclear Information System (INIS)

    Chen Jianzhen; Li Bin; Wei Kaixia; Guo Lanying; Qu Guopu

    2008-01-01

    An improved technology of online cable eccentricity detection, based on X-ray CCD, greatly improves the measuring precision and the responding speed. The theory of eccentricity measuring based on X-ray CCD, and the structure of an apparatus are described. The apparatus is composed of scanning drive subsystem, X-ray generation components, data acquiring subsystem and high performance computer system. The measuring results are also presented. The features of this cable eccentricity detection technology are compared with the features of other technologies. (authors)

  18. X-rays detection system to obtain digital imagines for the study of artworks

    International Nuclear Information System (INIS)

    Bolanos, L.; Cabal, A. E.; Diaz, A.; Ramello, L.; Prino, F.; Giubellino, P.; Marzari-Chiesa, A.; Grybos, P.; Maj, P.; Gambaccini, M.; Petrucci, F.; Albertin, F.

    2008-01-01

    X-ray radiography plays an important role in the study of artworks. It particularly provides information on the origin, authenticity, painting technique, material conditions and its conservation history. This article describes a system based on semiconductor microstrip detector for obtaining X-ray images using the k-edge logarithmic substraction technique. The system has been characterized and the first images of its application for pigment detection are shown. (Author)

  19. Testing of x-ray microtomography systems using a traceable geometrical standard

    International Nuclear Information System (INIS)

    Carmignato, S; Dreossi, D; Mancini, L; Tromba, G; Marinello, F; Savio, E

    2009-01-01

    X-ray computed microtomography is an interesting imaging technique for many applications, and is also very promising in the field of coordinate metrology at the micro scale. The main advantage with respect to traditional tactile-probing or optical coordinate measurement systems is that x-ray tomography can acquire dimensional and geometrical data for both inner and outer surfaces, without accessibility restrictions. However, there are no accepted test procedures available so far and measurement uncertainty is unknown in many cases, due to complex and numerous error sources. The paper presents the first results of a test procedure implemented for determining the errors of indication for length measurements of x-ray microtomography systems, using a new reference standard featuring a regular array of inner and outer cylindrical shapes. The developed test method allows the determination of specific characteristics of x-ray microtomography systems and can be used for the correction of systematic errors

  20. A development of laser-plasma-based soft x-ray microscope system

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ki Yong; Kim, Kyong Woo; Kim, Kyu Gyeom; Kwon, Young Man; Yoon, Kwon Ha [X-ray Microscopy Research Center, Wonkwang University, Iksan (Korea, Republic of)

    2003-07-01

    Soft x-ray nano-imaging microscopy system for biomedical application with a high resolution about 50 nm has been designed and described, and its integrated techniques also have been studied. The system is mainly composed of soft x-ray generation system, nano-scaled control system, x-ray optical device like a condenser or object mirror, a CCD camera coupled with multichannel plate (MCP) and vacuum system. In the system, soft x-ray is generated from the laser-based plasma by focusing Nd:YAG laser beam on tantalum (Ta) target. In an x-ray optical system, a wolter mirror has been considering condensing the x-ray beam on a biological specimen and zone plate was adapted as an object mirror. A Si{sub 3}N{sub 4} was used as specimen holder for keeping a biological sample alive in atmosphere conditions. A back-illuminated-CCD camera coupled with multichannel plate was determined to set up.

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  2. Development of a portable system of X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Mantuano, Andrea; Crisostomo, Jose V.V.; Barros, Mariana J.; Oliveira, Luis F.; Barroso, Regina C.

    2009-01-01

    This paper develops a compact and portable spectrometry system that will be used at the Laboratory of Applied Physics to the Biomedical and Environmental Sciences of the Institute of Physics/UERJ, Rio de Janeiro, Brazil. The laboratory both prepares the samples and develops the X-ray spectrometry techniques. The techniques of X-ray diffraction and fluorescence on various samples (biological, industrial and environmental) are used, attending to pos-graduation and graduation students, with multidisciplinary characteristics. The Mini-X system consists of X-ray mini tube MINI-X from Amptek with tungsten (W) target, and a compact spectrometer X123, also from Amptek that includes a detector, pre-amplifier, digital pulse processor, and multichannel. All the system is controlled by dedicated microprocessor. This work will present both a methodology for alignment and calibration of the system as far the first measurements performed using the X-ray fluorescence technique on standard samples. The multi elementary analysis by X-ray fluorescence (XRF) is based on the measurements of the characteristic X-ray intensity emitted by the chemical elements components of the samples when excited. Therefore, from the development of this compact and versatile system it will be possible to obtain the fluorescent intensities of the analysed samples at the Laboratory, not only at the research area but at the teaching area. Besides, new laboratory practices are being developed for the discipline of medical physics

  3. Soft X-ray synchrotron radiation investigations of actinide materials systems utilizing X-ray emission spectroscopy and resonant inelastic X-ray scattering

    International Nuclear Information System (INIS)

    Shuh, D.K.; Butorin, S.M.; Guo, J.-H.; Nordgren, J.

    2004-01-01

    Synchrotron radiation (SR) methods have been utilized with increasing frequency over the past several years to study topics in actinide science, ranging from those of a fundamental nature to those that address a specifically-targeted technical need. In particular, the emergence of microspectroscopic and fluorescence-based techniques have permitted investigations of actinide materials at sources of soft x-ray SR. Spectroscopic techniques with fluorescence-based detection are useful for actinide investigations since they are sensitive to small amounts of material and the information sampling depth may be varied. These characteristics also serve to simplify both sample preparation and safety considerations. Examples of investigations using these fluorescence techniques will be described along with their results, as well as the prospects for future investigations utilizing these methodologies

  4. Simple microprocessor-based system for upgrading existing X-ray equipment for analysis

    International Nuclear Information System (INIS)

    Souza, A.M. de

    1986-01-01

    A data acquisition and processing device appropriate for X-ray analysis and goniometer control was built. A conventional Z-80 based systems was used, and the interfacing architeture and the applicable soft-ware are described. The advantages and new possibilities of the automated instrument as compared to previous ones are listed. It is shown that the X-ray diffraction and fluorescence techniques can take advantage of the automation using existing instruments. (Author) [pt

  5. Development of the GEM-TPC X-ray Polarimeter with the Scalable Readout System

    Directory of Open Access Journals (Sweden)

    Kitaguchi Takao

    2018-01-01

    Full Text Available We have developed a gaseous Time Projection Chamber (TPC containing a single-layered foil of a gas electron multiplier (GEM to open up a new window on cosmic X-ray polarimetry in the 2–10 keV band. The micro-pattern TPC polarimeter in combination with the Scalable Readout System produced by the RD51 collaboration has been built as an engineering model to optimize detector parameters and improve polarimeter sensitivity. The polarimeter was characterized with unpolarized X-rays from an X-ray generator in a laboratory and polarized X-rays on the BL32B2 beamline at the SPring-8 synchrotron radiation facility. Preliminary results show that the polarimeter has a comparable modulation factor to a prototype of the flight one.

  6. Combination use of lentinan with x-ray therapy in mouse experimental tumor system, (3)

    International Nuclear Information System (INIS)

    Shiio, Tsuyoshi; Ohishi, Kazuo; Niitsu, Iwayasu; Hayashibara, Hiromi; Tsuchiya, Yoshiharu; Yoshihama, Takashi; Moriyuki, Hirobumi

    1988-01-01

    Combination effect of lentinan with X-ray irradiation on the metastatic mouse tumors, L1210, KLN205 and Lewis lung carcinoma were studied. Combination use of lentinan with X-ray therapy prolonged the life of BDF 1 mice bearing L1210 leukemia in the suitable combination conditions. Combination effects of lentinan with X-ray therapy were also observed on the suppression of the growth of KLN205 squamus cell carcinoma and on the suppression of the metastasis of Lewis lung carcinoma. Especially, in the case that lentinan was administered before or after X-ray local irradiation in the pulmorary metastasis system of Lewis lung carcinoma, a marked suppressin of pulmonary metastasis was observed and 2 to 4 mice among 8 tested mice were tumor free. (author)

  7. The Elusive Soft Emission from Hard X-ray Symbiotic System RT Cru

    Science.gov (United States)

    Karovska, Margarita

    2014-09-01

    RT Cru is a fascinating member of a new class of hard X-ray emitting symbiotic binaries showing X-ray emission extending to over 50keV. While its hard X-ray emission has been studied in detail, the soft component of the spectrum, including flares, remains elusive, since previous observations have focused on the high-energy regime. We propose Chandra HRC-S/LETG observations to determine the spatial, spectral, and temporal characteristics of the source of the soft X-ray emission with a goal to establish the origin of the soft component, and determine whether and how it is tied to the hard component. Determining the origin of the soft emission is a crucial piece of the puzzle to understanding the geometry, energetics, and the environment of WD accretion in this class of symbiotic systems.

  8. Optical systems for synchrotron radiation: lecture 4. Soft x-ray imaging systems

    International Nuclear Information System (INIS)

    Howells, M.R.

    1986-04-01

    The history and present techniques of soft x-ray imaging are reviewed briefly. The physics of x-ray imaging is described, including the temporal and spatial coherence of x-ray sources. Particular technologies described are: contact x-ray microscopy, zone plate imaging, scanned image zone plate microscopy, scanned image reflection microscopy, and soft x-ray holography and diffraction

  9. Resonant inelastic X-ray scattering spectra at the Ir L-edge in Na{sub 2}IrO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, Jun-ichi, E-mail: junichi.igarashi.kiryu@vc.ibaraki.ac.jp [Faculty of Science, Ibaraki University, Mito, Ibaraki 310-8512 (Japan); Nagao, Tatsuya, E-mail: nagao@gunma-u.ac.jp [Faculty of Engineering, Gunma University, Kiryu, Gunma 376-8515 (Japan)

    2016-10-15

    Highlights: • A theoretical framework of resonant inelastic X-ray scattering (RIXS) on the basis of the itinerant electron scheme has been developed. • The RIXS theory is applied to iridate Na{sub 2}IrO{sub 3}. • The origins of the multi-peak structure of the excitation spectra found in the RIXS experiment have been assigned to the magnetic and excitonic excitations. - Abstract: We analyze resonant X-ray scattering (RIXS) spectra in Na{sub 2}IrO{sub 3} on the basis of the itinerant electron picture. Employing a multi-orbital tight-binding model on a honeycomb lattice, we find that the zigzag magnetic order is the most stable with sizable energy gap in the one-electron band within the Hartree–Fock approximation. We derive the RIXS spectra, which are connected to the generalized density–density correlation function. We calculate the spectra as a function of excitation energy ω, within the random phase approximation. The spectra consist of the peaks with ω < 20 meV, and of the peaks with 0.4 < ω < 0.8 eV. The former peaks are composed of four bound states in the density–density correlation function, and may be identified as the magnetic excitations, while the latter peaks are composed of 16 bound states below the energy continuum of individual electron–hole pair excitations, and may be identified as the excitonic excitations. The calculated spectra agree qualitatively with the recent RIXS experiment.

  10. Determination of manganese interdiffusion parameters in CoFe/IrMn bilayers by X-ray reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Batista, Pablo Forlam Ribeiro; Andrade, Leandro Hostalacio Freire; Fernandez-Outon, Luis Eugenio; Macedo, Waldemar Augusto de Almeida, E-mail: pfrb@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2016-07-01

    Full text: Interfacial diffusion is expected to have strong influence on the exchange bias coupling in ferromagnetic/antiferromagnetic bilayers, basic structures for spintronic devices [1]. In this work, X-ray reflectometry (XRR) in combination with the Fick's second law [2] was applied to determine manganese interdiffusion parameters in CoFe/IrMn exchange-biased bilayers prepared by magnetron sputtering. The layer thickness and the interfacial roughness of the samples were obtained by fitting the reflectivity curves and the values confirmed by transmission electron microscopy. The manganese diffusion coefficient at the interfaces is in the range of 10{sup -22} m{sup 2}/s, and the activation energy for the interfacial diffusion of manganese is in the order of a few tens of kJ/mol, based on the values of interfacial roughness for different annealing temperatures. References: [1] L. E. Fernandez-Outon, M. S. Araujo Filho, R. E. Araujo, J. D. Ardisson, and W. A. A. Macedo. J. Appl. Phys. 113, 17D704 (2013). [2] J. Y. Wang, A. Zalar, Y.H. Zhao, E.J. Mittemeijer. Thin Solid Films. 433, 92 (2003). (author)

  11. A set-up of micro-X-ray fluorescence system based on polycapillary X-ray optics and applications for archaeology

    International Nuclear Information System (INIS)

    Cheng Lin; Pan Qiuli; Ding Xunliang; Liu Zhiguo

    2008-01-01

    The paper concerns in the structures, performances and characteristics and applications for archaeology of a new micro-X-ray fluorescence system based on rotating anode X-ray generator and polycapillary X-ray optics. The polycapillary X-ray optics used here can focus the primary X-ray beam down to some tens of micrometers in diameters that allows for non-destructive and local analysis of sub-mm samples with minor/ trace level sensitivity. In order to prove the potentials of this instrument used in archaeology, a piece of Chinese ancient blue and white porcelain produced in Ming Dynasty was analyzed. The results show that intensities of Mn-Kα, Co-Kα are variable in agree with the thick of blue glaze. The correlation analysis indicates the Mn and Co have the best correlations. So, the concentrations or ratios of Mn and Co are crucial to determine the provenance and identify from a fake one of Chinese ancient blue and white porcelain. (authors)

  12. Fabrication of applicator system of miniature X-ray tube based on carbon nanotubes for a skin cancer therapy

    International Nuclear Information System (INIS)

    Park, Han Beom; Kim, Hyun Jin; Lee, Ju Hyuk; Ha, Jun Mok; Cho, Sung Oh

    2016-01-01

    A miniature X-ray tube is a small X-ray generation device generally with a diameter of less than 10 mm. Because of the feasible installation in a spatially constrained area and the possibility of electrical on/off control, miniature X-ray tubes can be widely used for nondestructive X-ray radiography, hand held X-ray spectrometers, electric brachytherapy, and interstitial or intracavitary radiation therapy or imaging with the substitution of radioactive isotopes. Miniature X-ray tubes have been developed mostly using thermionic electron sources or secondary X-ray emission. The X-ray tube show excellent field emission properties and good X-ray spectrum. Also, the flattening filter was made to irradiate uniformly. The X-ray dose radial uniformities between installed flattening filter and non-installed flattening filter were measured. When flattening filter is equipped, X-ray uniformity was improved from higher than 20% to lower than 10%. As a result, the fabricated applicator system of the miniature X-ray tube using optimized flattening filter exhibited fairly excellent properties

  13. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  14. X-ray instrumentation in astronomy

    International Nuclear Information System (INIS)

    Cuhlane, J.L.

    1985-01-01

    This book presents the proceedings of a conference devoted to x-ray instrumentation in astronomy. Special sections are: AXAF X-Ray Optical Systems; Specialized X-Ray Systems; X-Ray Optical Systems I; X-Ray Optical Systems II; Gas Filled X-Ray Detectors II; The NASA Advanced X-Ray Astrophysics Facility; X-Ray and EUV Spectrometers; Microchannel Plates; and Solid State Detectors

  15. A Magnetron Sputter Deposition System for the Development of X-Ray Multilayer Optics

    Science.gov (United States)

    Broadway, David

    2015-01-01

    The project objective is to establish the capability to deposit multilayer structures for x-ray, neutron, and extreme ultraviolet (EUV) optic applications through the development of a magnetron sputtering deposition system. A specific goal of this endeavor is to combine multilayer deposition technology with the replication process in order to enhance NASA Marshall Space Flight Center's (MSFC's) position as a world leader in the design of innovative x-ray instrumentation through the development of full shell replicated multilayer optics. The development of multilayer structures are absolutely necessary in order to advance the field of x-ray astronomy by pushing the limit for observing the universe to ever-increasing photon energies (i.e., up to 200 keV or higher), well beyond Chandra's (approx.10 keV) and NuStar's (approx.75 keV) capability. The addition of multilayer technology would significantly enhance the x-ray optics capability at MSFC and allow NASA to maintain its world leadership position in the development, fabrication, and design of innovative x-ray instrumentation, which would be the first of its kind by combining multilayer technology with the mirror replication process. This marriage of these technologies would allow astronomers to see the universe in a new light by pushing to higher energies that are out of reach with today's instruments. To this aim, a magnetron vacuum sputter deposition system for the deposition of novel multilayer thin film x-ray optics is proposed. A significant secondary use of the vacuum deposition system includes the capability to fabricate multilayers for applications in the field of EUV optics for solar physics, neutron optics, and x-ray optics for a broad range of applications including medical imaging.

  16. A Magnetron Sputter Deposition System for the Development of Multilayer X-Ray Optics

    Science.gov (United States)

    Broadway, David; Ramsey, Brian; Gubarev, Mikhail

    2014-01-01

    The proposal objective is to establish the capability to deposit multilayer structures for x-ray, neutron, and EUV optic applications through the development of a magnetron sputtering deposition system. A specific goal of this endeavor is to combine multilayer deposition technology with the replication process in order to enhance the MSFC's position as a world leader in the design of innovative X-ray instrumentation through the development of full shell replicated multilayer optics. The development of multilayer structures is absolutely necessary in order to advance the field of X-ray astronomy by pushing the limit for observing the universe to ever increasing photon energies (i. e. up to 200 keV or higher); well beyond Chandra (approx. 10 keV) and NuStar's (approx. 75 keV) capability. The addition of multilayer technology would significantly enhance the X-ray optics capability at MSFC and allow NASA to maintain its world leadership position in the development, fabrication and design of innovative X-ray instrumentation which would be the first of its kind by combining multilayer technology with the mirror replication process. This marriage of these technologies would allow astronomers to see the universe in a new light by pushing to higher energies that are out of reach with today's instruments.To this aim, a magnetron vacum sputter deposition system for the deposition of novel multilayer thin film X-ray optics is proposed. A significant secondary use of the vacuum deposition system includes the capability to fabricate multilayers for applications in the field of EUV optics for solar physics, neutron optics, and X-ray optics for a broad range of applications including medical imaging.

  17. Development of an X-ray imaging system with SOI pixel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Ryutaro, E-mail: ryunishi@post.kek.jp [School of High Energy Accelerator Science, SOKENDAI (The Graduate University for Advanced Studies), Oho 1-1, Tsukuba, Ibaraki 305-0801 (Japan); Arai, Yasuo; Miyoshi, Toshinobu [Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK-IPNS), Oho 1-1, Tsukuba, Ibaraki 305-0801 (Japan); Hirano, Keiichi; Kishimoto, Shunji; Hashimoto, Ryo [Institute of Materials Structure Science, High Energy Accelerator Research Organization (KEK-IMSS), Oho 1-1, Tsukuba, Ibaraki 305-0801 (Japan)

    2016-09-21

    An X-ray imaging system employing pixel sensors in silicon-on-insulator technology is currently under development. The system consists of an SOI pixel detector (INTPIX4) and a DAQ system based on a multi-purpose readout board (SEABAS2). To correct a bottleneck in the total throughput of the DAQ of the first prototype, parallel processing of the data taking and storing processes and a FIFO buffer were implemented for the new DAQ release. Due to these upgrades, the DAQ throughput was improved from 6 Hz (41 Mbps) to 90 Hz (613 Mbps). The first X-ray imaging system with the new DAQ software release was tested using 33.3 keV and 9.5 keV mono X-rays for three-dimensional computerized tomography. The results of these tests are presented. - Highlights: • The X-ray imaging system employing the SOI pixel sensor is currently under development. • The DAQ of the first prototype has the bottleneck in the total throughput. • The new DAQ release solve the bottleneck by parallel processing and FIFO buffer. • The new DAQ release was tested using 33.3 keV and 9.5 keV mono X-rays.

  18. The design of a measuring system for soft X ray absolute intensity

    International Nuclear Information System (INIS)

    Cui Congwu; Cui Mingqi

    1997-01-01

    The design of a measuring system for soft X ray absolute intensity in detail is presented. The system consists of two parts: the ionization chamber, the silicon photodiode and its transferring system. The system can be used as the primary standard detector for the measurement of soft X ray absolute radiation flux in the energy range of 50 to 2000 eV after being calibrated. The whole system will be installed to the newly built beamline of 3W1B at Beijing Synchrotron Radiation Facility

  19. Advances in indirect detector systems for ultra high-speed hard X-ray imaging with synchrotron light

    Science.gov (United States)

    Olbinado, M. P.; Grenzer, J.; Pradel, P.; De Resseguier, T.; Vagovic, P.; Zdora, M.-C.; Guzenko, V. A.; David, C.; Rack, A.

    2018-04-01

    We report on indirect X-ray detector systems for various full-field, ultra high-speed X-ray imaging methodologies, such as X-ray phase-contrast radiography, diffraction topography, grating interferometry and speckle-based imaging performed at the hard X-ray imaging beamline ID19 of the European Synchrotron—ESRF. Our work highlights the versatility of indirect X-ray detectors to multiple goals such as single synchrotron pulse isolation, multiple-frame recording up to millions frames per second, high efficiency, and high spatial resolution. Besides the technical advancements, potential applications are briefly introduced and discussed.

  20. Description of EMX computer code. System for measuring soft X rays

    International Nuclear Information System (INIS)

    Marty, D.A.; Smeulders, P.; Launois, D.

    1978-07-01

    After briefly describing the system for measuring soft X rays implanted in TFR 600, the objectives and principles of the E.M.X calculation programme are presented. This model is divided into two distinct parts. The ultimate aim of EMX 1, the first part, is to build the soft X ray photo of a plasma with varied characteristics, seen through a certain collimation system (in this case a slit). That of EMX 2, the second part, is to filter the previously built soft X ray photo, by means of the system of absorbents belonging to the measuring system and to calculate the currents generated by each detector aimed at a plasma chord. The first calculation results are commented and discussed [fr

  1. A new cone-beam X-ray CT system with a reduced size planar detector

    International Nuclear Information System (INIS)

    Li Liang; Chen Zhiqiang; Zhang Li; Xing Yuxiang; Kang Kejun

    2006-01-01

    In a traditional cone-beam CT system, the cost of product and computation is very high. The authors propose a transversely truncated cone-beam X-ray CT system with a reduced size detector positioned off-center, in which X-ray beams only cover half of the object. The reduced detector size cuts the cost and the X-ray dose of the CT system. The existing CT reconstruction algorithms are not directly applicable in this new CT system. Hence, the authors develop a BPF-type direct backprojection algorithm. Different from the traditional rebinding methods, our algorithm directly backprojects the pretreated projection data without rebinding. This makes the algorithm compact and computationally more efficient. Finally, some numerical simulations and practical experiments are done to validate the proposed algorithm. (authors)

  2. Computerized tomography using high resolution X-ray imaging system with a microfocus source

    International Nuclear Information System (INIS)

    Zaprazny, Z.; Korytar, D.; Konopka, P.; Ac, V.; Bielecki, J.

    2011-01-01

    In recent years there is an effort to image an internal structure of an object by using not only conventional 2D X-ray radiography but also using high resolution 3D tomography which is based on reconstruction of multiple 2D projections at various angular positions of the object. We have previously reported [1] the development and basic parameters of a high resolution x-ray imaging system with a microfocus source. We report the recent progress using this high resolution X-ray laboratory system in this work. These first findings show that our system is particularly suitable for light weight and nonmetallic objects such as biological objects, plastics, wood, paper, etc. where phase contrast helps to increase the visibility of the finest structures of the object. Phase-contrast X-ray Computerized Tomography is of our special interest because it is an emerging imaging technique that can be implemented at third generation synchrotron radiation sources and also in laboratory conditions using a microfocus X-ray tube or beam conditioning optics. (authors)

  3. SEXTANT X-Ray Pulsar Navigation Demonstration: Flight System and Test Results

    Science.gov (United States)

    Winternitz, Luke; Mitchell, Jason W.; Hassouneh, Munther A.; Valdez, Jennifer E.; Price, Samuel R.; Semper, Sean R.; Yu, Wayne H.; Ray, Paul S.; Wood, Kent S.; Arzoumanian, Zaven; hide

    2016-01-01

    The Station Explorer for X-ray Timing and Navigation Technology (SEXTANT) is a technology demonstration enhancement to the Neutron-star Interior Composition Explorer (NICER) mission. NICER is a NASA Explorer Mission of Opportunity that will be hosted on the International Space Station (ISS). SEXTANT will, for the first time, demonstrate real-time, on-board X-ray Pulsar Navigation (XNAV), a significant milestone in the quest to establish a GPS-like navigation capability available throughout our Solar System and beyond. This paper gives an overview of the SEXTANT system architecture and describes progress prior to environmental testing of the NICER flight instrument. It provides descriptions and development status of the SEXTANT flight software and ground system, as well as detailed description and results from the flight software functional and performance testing within the high-fidelity Goddard Space Flight Center (GSFC) X-ray Navigation Laboratory Testbed (GXLT) software and hardware simulation environment. Hardware-in-the-loop simulation results are presented, using the engineering model of the NICER timing electronics and the GXLT pulsar simulator-the GXLT precisely controls NASA GSFC's unique Modulated X-ray Source to produce X-rays that make the NICER detector electronics appear as if they were aboard the ISS viewing a sequence of millisecond pulsars

  4. Incoherent-scatter computed tomography with monochromatic synchrotron x ray: feasibility of multi-CT imaging system for simultaneous measurement-of fluorescent and incoherent scatter x rays

    Science.gov (United States)

    Yuasa, T.; Akiba, M.; Takeda, T.; Kazama, M.; Hoshino, A.; Watanabe, Y.; Hyodo, K.; Dilmanian, F. A.; Akatsuka, T.; Itai, Y.

    1997-10-01

    We describe a new system of incoherent scatter computed tomography (ISCT) using monochromatic synchrotron X rays, and we discuss its potential to be used in in vivo imaging for medical use. The system operates on the basis of computed tomography (CT) of the first generation. The reconstruction method for ISCT uses the least squares method with singular value decomposition. The research was carried out at the BLNE-5A bending magnet beam line of the Tristan Accumulation Ring in KEK, Japan. An acrylic cylindrical phantom of 20-mm diameter containing a cross-shaped channel was imaged. The channel was filled with a diluted iodine solution with a concentration of 200 /spl mu/gI/ml. Spectra obtained with the system's high purity germanium (HPGe) detector separated the incoherent X-ray line from the other notable peaks, i.e., the iK/sub /spl alpha// and K/sub /spl beta/1/ X-ray fluorescent lines and the coherent scattering peak. CT images were reconstructed from projections generated by integrating the counts In the energy window centering around the incoherent scattering peak and whose width was approximately 2 keV. The reconstruction routine employed an X-ray attenuation correction algorithm. The resulting image showed more homogeneity than one without the attenuation correction.

  5. Radiography simulation on single-shot dual-spectrum X-ray for cargo inspection system

    International Nuclear Information System (INIS)

    Gil, Youngmi; Oh, Youngdo; Cho, Moohyun; Namkung, Won

    2011-01-01

    We propose a method to identify materials in the dual energy X-ray (DeX) inspection system. This method identifies materials by combining information on the relative proportions T of high-energy and low-energy X-rays transmitted through the material, and the ratio R of the attenuation coefficient of the material when high-energy are used to that when low energy X-rays are used. In Monte Carlo N-Particle Transport Code (MCNPX) simulations using the same geometry as that of the real container inspection system, this T vs. R method successfully identified tissue-equivalent plastic and several metals. In further simulations, the single-shot mode of operating the accelerator led to better distinguishing of materials than the dual-shot system.

  6. Network based multi-channel digital flash X-ray imaging system

    International Nuclear Information System (INIS)

    Wang Jingjin; Yuan Jie; Liu Yaqiang; Lin Yong; Song Zheng; Liu Keyin; Zhang Qi; Zheng Futang

    2000-01-01

    A network based multi-channel digital flash X-ray imaging system has been developed. It can be used to acquire and digitize orthogonal flash X-ray images in multi-interval, and to distribute the images on the network. There is no need of films and chemical process, no anxiety of waiting and no trouble of film archiving. This system is useful for testing ballistics, jet, explode, armour-piercing and fast running machines. The system composing and acquired images are presented. The software for object separating, mass calculating, 3D positioning, speed determining and cavity reconstruction are described

  7. Network based multi-channel digital flash X-ray imaging system

    International Nuclear Information System (INIS)

    Wang Jingjin; Yuan Jie; Liu Yaqiang; Lin Yong; Song Zheng; Liu Keyin

    2003-01-01

    A network based multi-channel digital flash X-ray imaging system has been developed. It can be used to acquire and digitize orthogonal flash X-ray images in multi-interval, and to distribute the images on the network. There is no need of films and chemical process, no anxiety of waiting and no trouble of film archiving. This system is useful for testing ballistics, jet, explode, armour-piercing and fast running machines. The system composing and acquired images of terminal ballistics are presented. The software for object separating, profile calculating and 3D cavity reconstruction are described

  8. High energy X-ray CT system using a linear accelerator for automobile parts inspection

    International Nuclear Information System (INIS)

    Kanamori, T.; Sukita, T.

    1995-01-01

    A high energy X-ray CT system (maximum photon energy: 0.95 MeV) has been developed for industrial use. This system employs a linear accelerator as an X-ray source. It is able to image the cross section of automobile parts and can be applied to a solidification analysis study of the cylinder head in an automobile. This paper describes the features of the system and application results which can be related to solidification analysis of the cylinder head when fabricated from an aluminum casting. Some cross-sectional images are also presented as evidence for nondestructive inspection of automobile parts. (orig.)

  9. On the limitations and optimisation of high-resolution 3D medical X-ray imaging systems

    International Nuclear Information System (INIS)

    Zhou Shuang; Brahme, Anders

    2011-01-01

    Based on a quantitative analysis of both attenuation and refractive properties of X-ray propagation in human body tissues and the introduction of a mathematical model for image quality analysis, some limitations and optimisation of high-resolution three-dimensional (3D) medical X-ray imaging techniques are studied. A comparison is made of conventional attenuation-based X-ray imaging methods with the phase-contrast X-ray imaging modalities that have been developed recently. The results indicate that it is theoretically possible through optimal design of the X-ray imaging system to achieve high spatial resolution (<100 μm) in 3D medical X-ray imaging of the human body at a clinically acceptable dose level (<10 mGy) by introducing a phase-contrast X-ray imaging technique.

  10. Short-period AM CVn systems as optical, X-ray and gravitational-wave sources

    NARCIS (Netherlands)

    Nelemans, G.; Yungelson, L.; Portegies Zwart, S.F.

    2004-01-01

    We model the population of AM CVn systems in the Galaxy and discuss the detectability of these systems with optical, X-ray and gravitational-wave detectors. We concentrate on the short-period (P < 1500 s) systems, some of which are expected to be in a phase of direct-impact accretion. Using a

  11. In-flight calibration system for the INTEGRAL x-ray monitor

    DEFF Research Database (Denmark)

    Costa, E.; Feroci, M.; Barbanera, L.

    1996-01-01

    of Amptek Cool-X15 X-ray generators. The latter is a novel product, based on a pyroelectric crystal used to generate energetic electrons that produce fluorescence lines by hitting a metallic target. We plan to use the four low intensity radioactive sources for monitoring the four independent anode chains......JEM-X is the x-ray monitor serving the two gamma-ray experiments imager and spectrometer onboard the ESA's INTEGRAL satellite. Due to the intrinsic weakness of the celestial sources in the gamma energy range they will need very long integration times. During these long pointings JEM-X will be able...... to detect very small variations on most x-ray sources, but only if accurately calibrated. The in- flight calibration system of the JEM-X experiment is devoted to measure the response of the detection chain (detector plus electronics) in a small set of positions and energies. The data from this system...

  12. Operation of the ultrasoft x-ray system on NSTX (abstract)

    International Nuclear Information System (INIS)

    Stutman, D.; Iovea, M.; Finkenthal, M.; Kaita, R.; Johnson, D.; Roquemore, L.; Roney, P.

    2001-01-01

    The ultrasoft x-ray imaging system on National Spherical Torus Experiment (NSTX) became operational and provided the first data in the filtered diode slow bow tie configuration. Using different band pass filters on each of three arrays allows an approximate spectroscopic estimate of the plasma impurity content, as well as of the electron temperature. Magnetohydrodynamics (MHD) activity from different plasma regions is also observed. The soft x-ray emission profiles are well behaved until an Internal Reconnection Event occurs. Examples of NSTX MHD phenomena seen in the ultrasoft x-ray emission under different operational regimes will be presented. From a technical point of view, we point out that the industrial PC based data acquisition system was not adversely affected by stray magnetic fields due to its close proximity to the NSTX device. Also, the surface barrier diodes withstood baking to 100 o C relatively well

  13. Simulations of X-ray synchrotron beams using the EGS4 code system in medical applications

    International Nuclear Information System (INIS)

    Orion, I.; Henn, A.; Sagi, I.; Dilmanian, F.A.; Pena, L.; Rosenfeld, A.B.

    2001-01-01

    X-ray synchrotron beams are commonly used in biological and medical research. The availability of intense, polarized low-energy photons from the synchrotron beams provides a high dose transfer to biological materials. The EGS4 code system, which includes the photoelectron angular distribution, electron motion inside a magnetic field, and the LSCAT package, found to be the appropriate Monte Carlo code for synchrotron-produced X-ray simulations. The LSCAT package was developed in 1995 for the EGS4 code to contain the routines to simulate the linear polarization, the bound Compton, and the incoherent scattering functions. Three medical applications were demonstrated using the EGS4 Monte Carlo code as a proficient simulation code system for the synchrotron low-energy X-ray source. (orig.)

  14. X-ray image intensifier/television systems for digital skeletal radiography

    International Nuclear Information System (INIS)

    Rowlands, J.A.; Hynes, D.M.; Edmonds, E.W.; Porter, A.J.; Toth, B.J.

    1987-01-01

    The imaging criteria for skeletal radiography (high resolution and low noise) relevant to the use of x-ray image intensifier/TV digital systems are discussed. It is shown from the modulation transfer function (MTF), noise, and phantom evaluations that conventional x-ray image intensifiers in conjunction with a 1,000-line Plumbicon or Saticon TV camera are in most respects suitable for skeletal radiography. The optimum focal spot size depends on a trade-off with motion blurring through the x-ray exposure time and so is a function of the clinical problem. Since the skeletal system is readily immobilized, a 0.3-mm focal spot size is nearly optimum

  15. Soft X-ray spectromicroscopy of biological and synthetic polymer systems

    International Nuclear Information System (INIS)

    Hitchcock, A.; Morin, C.; Araki, T.; Zhang, X.; Dynes, J.; Stover, H.; Brash, J.

    2004-01-01

    Full text: Scanning transmission X-ray microscopy (STXM) and X-ray photoemission electron microscopy (X-PEEM) are synchrotron based, soft X-ray spectromicroscopy techniques which provide chemical speciation at 50 nm spatial resolution based on near edge X-ray absorption spectral (NEXAFS) contrast. The instrumentation and techniques of soft X-ray spectro- microscopy will be described and illustrated with applications to wet biofilms, protein interactions with patterned polymer surfaces, and polymer microstructure optimization. STXM can be applied to samples in air, He, vacuum, or a fully hydrated environment. With many collaborators, my group is using STXM to study fundamental and applied aspects of polymer microstructure, to map metal ions and anti-microbial agents in wet biofilms, and to identify sites of selective adsorption of proteins on phase separated polymer thin films in the presence of an overlayer of protein solution. X-PEEM has greater surface sensitivity than STXM but requires a flat, conductive, and vacuum-compatible sample. Comparison of X-PEEM and STXM for the same system - fibrinogen adsorption on a PS:PMMA blend, will be used to illustrate advantages and limitations of each technique. Measurements at 5.3.2 STXM and 7.3.1 PEEM at the Advanced Light Source, funded by DoE under contract DE-AC03- 76SF00098. Research supported by NSERC (Canada), AFMnet (Advanced Food and Biomaterials Network) and the Canada Research Chair program

  16. Development of an X-ray fluorescence holographic measurement system for protein crystals

    Energy Technology Data Exchange (ETDEWEB)

    Sato-Tomita, Ayana, E-mail: ayana.sato@jichi.ac.jp, E-mail: shibayam@jichi.ac.jp, E-mail: hayashi.koichi@nitech.ac.jp; Shibayama, Naoya, E-mail: ayana.sato@jichi.ac.jp, E-mail: shibayam@jichi.ac.jp, E-mail: hayashi.koichi@nitech.ac.jp; Okabe, Takahiro [Division of Biophysics, Department of Physiology, Jichi Medical University, Yakushiji, Shimotsuke 329-0498 (Japan); Happo, Naohisa [Department of Computer and Network Engineering, Graduate School of Information Sciences, Hiroshima City University, Asa-Minami-Ku, Hiroshima 731-3194 (Japan); Kimura, Koji [Department of Physical Science and Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555 (Japan); Matsushita, Tomohiro [Japan Synchrotron Radiation Research Institute (JASRI), SPring-8, Sayo, Hyogo 679-5198 (Japan); Park, Sam-Yong [Drug Design Laboratory, Department of Medical Life Science, Yokohama City University, Suehiro, Tsurumi, Yokohama 230-0045 (Japan); Sasaki, Yuji C. [Department of Advanced Material Science, Graduate School of Frontier Science, The University of Tokyo, Kashiwanoha, Kashiwa 277-8561 (Japan); Hayashi, Kouichi, E-mail: ayana.sato@jichi.ac.jp, E-mail: shibayam@jichi.ac.jp, E-mail: hayashi.koichi@nitech.ac.jp [Department of Physical Science and Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555 (Japan); Frontier Research Institute for Materials Science, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555 (Japan)

    2016-06-15

    Experimental procedure and setup for obtaining X-ray fluorescence hologram of crystalline metalloprotein samples are described. Human hemoglobin, an α{sub 2}β{sub 2} tetrameric metalloprotein containing the Fe(II) heme active-site in each chain, was chosen for this study because of its wealth of crystallographic data. A cold gas flow system was introduced to reduce X-ray radiation damage of protein crystals that are usually fragile and susceptible to damage. A χ-stage was installed to rotate the sample while avoiding intersection between the X-ray beam and the sample loop or holder, which is needed for supporting fragile protein crystals. Huge hemoglobin crystals (with a maximum size of 8 × 6 × 3 mm{sup 3}) were prepared and used to keep the footprint of the incident X-ray beam smaller than the sample size during the entire course of the measurement with the incident angle of 0°-70°. Under these experimental and data acquisition conditions, we achieved the first observation of the X-ray fluorescence hologram pattern from the protein crystals with minimal radiation damage, opening up a new and potential method for investigating the stereochemistry of the metal active-sites in biomacromolecules.

  17. Development of a lens-coupled CMOS detector for an X-ray inspection system

    International Nuclear Information System (INIS)

    Kim, Ho Kyung; Ahn, Jung Keun; Cho, Gyuseong

    2005-01-01

    A digital X-ray imaging detector based on a complementary metal-oxide-semiconductor (CMOS) image sensor has been developed for X-ray non-destructive inspection applications. This is a cost-effective solution because of the availability of cheap commercial standard CMOS image sensors. The detector configuration adopts an indirect X-ray detection method by using scintillation material and lens assembly. As a feasibility test of the developed lens-coupled CMOS detector as an X-ray inspection system, we have acquired X-ray projection images under a variety of imaging conditions. The results show that the projected image is reasonably acceptable in typical non-destructive testing (NDT). However, the developed detector may not be appropriate for laminography due to a low light-collection efficiency of lens assembly. In this paper, construction of the lens-coupled CMOS detector and its specifications are described, and the experimental results are presented. Using the analysis of quantum accounting diagram, inefficiency of the lens-coupling method is discussed

  18. Development of an X-ray fluorescence holographic measurement system for protein crystals

    International Nuclear Information System (INIS)

    Sato-Tomita, Ayana; Shibayama, Naoya; Okabe, Takahiro; Happo, Naohisa; Kimura, Koji; Matsushita, Tomohiro; Park, Sam-Yong; Sasaki, Yuji C.; Hayashi, Kouichi

    2016-01-01

    Experimental procedure and setup for obtaining X-ray fluorescence hologram of crystalline metalloprotein samples are described. Human hemoglobin, an α_2β_2 tetrameric metalloprotein containing the Fe(II) heme active-site in each chain, was chosen for this study because of its wealth of crystallographic data. A cold gas flow system was introduced to reduce X-ray radiation damage of protein crystals that are usually fragile and susceptible to damage. A χ-stage was installed to rotate the sample while avoiding intersection between the X-ray beam and the sample loop or holder, which is needed for supporting fragile protein crystals. Huge hemoglobin crystals (with a maximum size of 8 × 6 × 3 mm"3) were prepared and used to keep the footprint of the incident X-ray beam smaller than the sample size during the entire course of the measurement with the incident angle of 0°-70°. Under these experimental and data acquisition conditions, we achieved the first observation of the X-ray fluorescence hologram pattern from the protein crystals with minimal radiation damage, opening up a new and potential method for investigating the stereochemistry of the metal active-sites in biomacromolecules.

  19. X-ray system with coupled source drive and detector drive

    International Nuclear Information System (INIS)

    1976-01-01

    An electronic coupling replacing the (more expensive) mechanical coupling which controls the speed of two sets of two electric motors, one driving an X-ray source and the other an X-ray detector, is described. Source and detector are kept rotating in parallel planes with a fairly constant velocity ratio. The drives are controlled by an electronic system comprising a comparator circuit comparing the position-indicative signals, a process control circuit and an inverter switch. The control system regulates the speed of the electric motors. The signal processing is described

  20. Development of high-resolution x-ray CT system using parallel beam geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Akio, E-mail: akio.yoneyama.bu@hitachi.com; Baba, Rika [Central Research Laboratory, Hitachi Ltd., Hatoyama, Saitama (Japan); Hyodo, Kazuyuki [Institute of Materials Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan); Takeda, Tohoru [School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa (Japan); Nakano, Haruhisa; Maki, Koutaro [Department of Orthodontics, School of Dentistry Showa University, Ota-ku, Tokyo (Japan); Sumitani, Kazushi; Hirai, Yasuharu [Kyushu Synchrotron Light Research Center, Tosu, Saga (Japan)

    2016-01-28

    For fine three-dimensional observations of large biomedical and organic material samples, we developed a high-resolution X-ray CT system. The system consists of a sample positioner, a 5-μm scintillator, microscopy lenses, and a water-cooled sCMOS detector. Parallel beam geometry was adopted to attain a field of view of a few mm square. A fine three-dimensional image of birch branch was obtained using a 9-keV X-ray at BL16XU of SPring-8 in Japan. The spatial resolution estimated from the line profile of a sectional image was about 3 μm.

  1. Digital imaging system in mammography with X-ray of two different energies

    International Nuclear Information System (INIS)

    Swientek, K.; Dabrowski, W.; Grybos, P.; Wiacek, P.; Cabal Rodrigez, A. E.; Sanchez, C.C.; Gambaccini, M.; Gaitan, J.L.; Prino, F.; Ramello, L.

    2005-01-01

    The progress in nuclear medicine stimulates the higher quality of image processing at diminished radiation dose. In the presented apparatus system Si-microstrip detector with two-thresholds multichannel amplitude analyzer have been applied. Data acquisition system evaluates simultaneously images for two X-ray beams of different energies following the Bragg reflection of the primary beam from the mosaic crystal. The contrast cancellation technique has been tested using the simple mammography phantom. An efficacy of this method suitable for medical imaging could be significantly increased using an intensive X-ray source and sensitive detectors

  2. X-ray astronomy

    International Nuclear Information System (INIS)

    Culhane, J.L.; Sanford, P.W.

    1981-01-01

    X-ray astronomy has been established as a powerful means of observing matter in its most extreme form. The energy liberated by sources discovered in our Galaxy has confirmed that collapsed stars of great density, and with intense gravitational fields, can be studied by making observations in the X-ray part of the electromagnetic spectrum. The astronomical objects which emit detectable X-rays include our own Sun and extend to quasars at the edge of the Universe. This book describes the history, techniques and results obtained in the first twenty-five years of exploration. Space rockets and satellites are essential for carrying the instruments above the Earth's atmosphere where it becomes possible to view the X-rays from stars and nebulae. The subject is covered in chapters, entitled: the birth of X-ray astronomy; the nature of X-radiation; X-rays from the Sun; solar-flare X-rays; X-rays from beyond the solar system; supernovae and their remnants; X-rays from binary stars; white dwarfs and neutron stars; black holes; X-rays from galaxies and quasars; clusters of galaxies; the observatories of the future. (author)

  3. Evaluation of a computer aided X-ray fluorographic system: part 1 - system analysis

    International Nuclear Information System (INIS)

    Burch, S.F.; Cocking, S.J.

    1982-02-01

    A computer aided, X-ray fluorographic (CAF) system has been assembled for application in non-destructive testing. The fluorographic hardware comprises a rare earth phosphor viewed with a low-light level SIT (Silicon intensifier target) TV camera, suitable for real time imaging in an industrial environment. A digital image processor allows integration to reduce noise and hence increase the thickness sensitivity. It also provides image modification for optimum visual detection of defects. Measurements of the resolution of the system and the noise on the fluorographic images are presented. Observations of wire type IQIs gave subjective thickness sensitivities of 2 to 4% for steel specimens up to 9mm thick. The observed noise was caused primarily by the camera rather than by the fundamental limit expected from X-ray photon statistics. The present system has, in practical applications, shown a capability to detect small (0.5mm) volumetric defects in castings. Further developments of the system are also discussed. It is concluded that a micro-focus X-ray set should be used with the existing hardware to investigate projection magnification fluoroscopy. (author)

  4. X-ray properties of the Be/X-ray systems 2S0114+650 LSI+65 deg 010

    International Nuclear Information System (INIS)

    Koenigsberger, G.; Swank, J.H.; Szymkowiak, A.E.

    1982-12-01

    Results are presented from experiments on the Einstein Observatory, HEAO-1 and OSO-8 on the temporal and spectral properties of 2S0114+650. In a 12 hour Einstein MPC and SSS observation two episodes of flaring occurred by an order of magnitude over about 1 hour. Variability on shorter time scales showed a preferred period of 14.9 minutes, but periodic pulsations were not seen in the HEAO-1 and OSO-8 data. There is some evidence that the spectrum is steeper when the source is quiescent at low luminosity, but no large spectral changes attended the flares. Absorption column densities were consistent with interstellar reddening of the proposed companion, the Be star LSI+65 deg 010. In the minute and hour variability and in the spectral character, 2S0114+650 is similar to other Be star-neutron star binary X-ray sources. Variations over several days in the OSO-8 data suggest orbital effects

  5. X-ray magnetic circular dichroism at IrL2,3 edges in Fe100−xIrx and ...

    Indian Academy of Sciences (India)

    2Japan Synchrotron Radiation Institute, SPring8, 1-1-1 Kouto, Mikazuki,. Hyogo 679-5198, Japan. ∗. Email: krishna@postman.riken.go.jp. Abstract. The formation of induced 5d magnetic moment on Ir in Fe100−x Irx (x=3, 10 and 17) and. Co100−x Irx (x =5, 17, 25 and 32) alloys has been investigated by X-ray magnetic ...

  6. Single x-ray transmission system for bone mineral density determination

    International Nuclear Information System (INIS)

    Jimenez-Mendoza, Daniel; Vargas-Vazquez, Damian; Espinosa-Arbelaez, Diego G.; Giraldo-Betancur, Astrid L.; Hernandez-Urbiola, Margarita I.; Rodriguez-Garcia, Mario E.

    2011-01-01

    Bones are the support of the body. They are composed of many inorganic compounds and other organic materials that all together can be used to determine the mineral density of the bones. The bone mineral density is a measure index that is widely used as an indicator of the health of the bone. A typical manner to evaluate the quality of the bone is a densitometry study; a dual x-ray absorptiometry system based study that has been widely used to assess the mineral density of some animals' bones. However, despite the success stories of utilizing these systems in many different applications, it is a very expensive method that requires frequent calibration processes to work properly. Moreover, its usage in small species applications (e.g., rodents) has not been quite demonstrated yet. Following this argument, it is suggested that there is a need for an instrument that would perform such a task in a more reliable and economical manner. Therefore, in this paper we explore the possibility to develop a new, affordable, and reliable single x-ray absorptiometry system. The method consists of utilizing a single x-ray source, an x-ray image sensor, and a computer platform that all together, as a whole, will allow us to calculate the mineral density of the bone. Utilizing an x-ray transmission theory modified through a version of the Lambert-Beer law equation, a law that expresses the relationship among the energy absorbed, the thickness, and the absorption coefficient of the sample at the x-rays wavelength to calculate the mineral density of the bone can be advantageous. Having determined the parameter equation that defines the ratio of the pixels in radiographies and the bone mineral density [measured in mass per unit of area (g/cm 2 )], we demonstrated the utility of our novel methodology by calculating the mineral density of Wistar rats' femur bones.

  7. Materials identification using a small-scale pixellated x-ray diffraction system

    International Nuclear Information System (INIS)

    O’Flynn, D; Crews, C; Drakos, I; Christodoulou, C; Speller, R D; Wilson, M D; Veale, M C; Seller, P

    2016-01-01

    A transmission x-ray diffraction system has been developed using a pixellated, energy-resolving detector (HEXITEC) and a small-scale, mains operated x-ray source (Amptek Mini-X). HEXITEC enables diffraction to be measured without the requirement of incident spectrum filtration, or collimation of the scatter from the sample, preserving a large proportion of the useful signal compared with other diffraction techniques. Due to this efficiency, sufficient molecular information for material identification can be obtained within 5 s despite the relatively low x-ray source power. Diffraction data are presented from caffeine, hexamine, paracetamol, plastic explosives and narcotics. The capability to determine molecular information from aspirin tablets inside their packaging is demonstrated. Material selectivity and the potential for a sample classification model is shown with principal component analysis, through which each different material can be clearly resolved. (paper)

  8. Monte Carlo simulations for stereotactic radiotherapy system with various kilo-voltage x-ray energy

    International Nuclear Information System (INIS)

    Deloar, H.M.; Kunieda, E.; Kawase, T.; Kubo, Atsushi; Saitoh, H.; Myojoyama, A.; Ozaki, M.; Fujisaki, T.; Saito, K.

    2005-01-01

    Stereotactic radiotherapy (SRT) of lung tumors with a narrow and precise medium energy x-ray beam where the homogeneous high dose area will be confined within the tumors are desirable. A conventional x-ray CT with medium energy x-ray has been modified to develop a radiotherapy system for lung SRT. A cylindrical collimator (0.3 cm φ) made of tungsten was introduced to collimate the X-ray beam. The system was simulated with BEAMnrc(EGS4) Monte Carlo code and various x-ray energy spectra were generated to investigate the dose distributions with our kilo-voltage SRT system. Experiments were performed to acquire the energy spectra of 100, 120 and 135 kVp (kilo-voltage peak) from CT measurements and those results were compared with the spectra obtained from Monte Carlo simulations. Verifications of percentage of dose depth (PDD) for 120 and 147.5 kVp were investigated in a water phantom with experiments and Monte Carlo simulations. Finally dose distributions of 120, 135, 147.5, 200, 250, 300, 350, 400, 500 kVp spectra were investigated with lung phantom and human lung. The Percentage of Depth Dose (PDD) in the water phantom calculated from the experimental and simulated spectra of 120 and 147.5 kVp show good agreement with each other. The PDD of 147.5 and 120 kVp spectra at 9 cm depth was approximately 10% and 9%, respectively. Dose distributions around the lung tumor in the phantom and human for all x-ray energies were almost uniform but in the case of the human lung absorptions of dose at ribs for the energy lower than 135 kVp was more than 35% and those absorptions for the energy spectra of 147.5 kVp and above was less than 30%. This absorption gradually decreases with increasing x-ray energies. Uniform dose distributions in the lung region of human and thorax phantom demonstrated the possibility of SRT system with medium energy X-ray. A detail performance of this system as a kilo-voltage conformal radiotherapy is under investigations. (author)

  9. The very soft X-ray spectrum of the double pulsar system J0737-3039

    NARCIS (Netherlands)

    Possenti, A.; Rea, N.; McLaughlin, M.A.; Camilo, F.; Kramer, M.; Burgay, M.; Joshi, B.C.; Lyne, A.G.

    2008-01-01

    We present the results of an 80 ks Chandra ACIS-S observation of the double pulsar system J0737-3039. Furthermore, we report on spectral, spatial and timing analysis of the combined X-ray observations performed so far for this system. Fitting a total of similar to 1100 photons, we show that the

  10. 49 CFR 1544.211 - Use of X-ray systems.

    Science.gov (United States)

    2010-10-01

    ...) Defect notice or modification order. No aircraft operator may use any X-ray system that is not in full compliance with any defect notice or modification order issued for that system by the FDA, unless the FDA has... genetic injury, to any person. (e) Signs and inspection of photographic equipment and film. (1) At...

  11. 49 CFR 1546.209 - Use of X-ray systems.

    Science.gov (United States)

    2010-10-01

    ...) Defect notice or modification order. No foreign air carrier may use any X-ray system that is not in full compliance with any defect notice or modification order issued for that system by the FDA, unless the FDA has... genetic injury, to any person. (e) Signs and inspection of photographic equipment and film. (1) At...

  12. Moisture movement in cement-based repair systems monitored by X-ray absorption

    NARCIS (Netherlands)

    Lukovic, M.; Ye, G.; Schlangen, H.E.J.G.; van Breugel, K.

    2017-01-01

    In concrete repair systems, material properties in the repair material and interface are greatly influenced by the initial moisture content of the concrete (or mortar) substrate. In order to quantify moisture profiles inside the repair system, X-ray absorption was used. Preliminary studies are

  13. A digital x-ray imaging MWPC detector system for precision absorptiometry

    International Nuclear Information System (INIS)

    Batemen, J.E.; Connolly, J.F.; Glasgow, W.

    1977-11-01

    An X-ray absorptiometric imaging system (based on a xenon-filled multiwire proportional counter) has been developed with high counting rate capability, good spatial resolution and linear mass response, aimed at permitting bone mass measurements to be made in the peripheral skeleton with precision approaching 1%. The system is described and preliminary results on test phantoms are presented. (author)

  14. Magnetism in heterogeneous thin film systems: Resonant X-ray scattering studies

    International Nuclear Information System (INIS)

    Kortright, J.B.; Jiang, J.S.; Bader, S.D.; Hellwig, O.; Marguiles, D.T.; Fullerton, E.E.

    2002-01-01

    Magnetic and chemical heterogeneity are common in a broad range of magnetic thin film systems. Emerging resonant soft x-ray scattering techniques are well suited to resolve such heterogeneity at relevant length scales. Resonant x-ray magneto-optical Kerr effect measurements laterally average over heterogeneity but can provide depth resolution in different ways, as illustrated in measurements resolving reversible and irreversible changes in different layers of exchange-spring heterostructures. Resonant small-angle scattering measures in-plane heterogeneity and can resolve magnetic and chemical scattering sources in different ways, as illustrated in measurements of granular alloy recording media

  15. X-ray semiotics of changes in the osteoarticular system in diabetes mellitus

    International Nuclear Information System (INIS)

    Spuzyak, M.I.; Bajzul'dina, A.N.

    1987-01-01

    The frequency and nature of the involvement of different parts of the skeleton were established on the basis of an X-ray study of the osteoarticular system in 274 patients with diabetes mellitus, X-ray changes in the bones and joints occurred in 98.7% of the patients and manifested themselves in osteoporosis (88%), cyst-like structural rearrangement (54%), osteolysis and destruction (12%), hyperosis (78%), degenerative-dystrophic articular changes (37.6%), vertebral changes (90.2%) and arthropathy (4.4%)

  16. International workshop on resonant X-ray scattering in electrically-ordered systems

    Energy Technology Data Exchange (ETDEWEB)

    Collins, S.P.; Pettifer, R.F.; Laundy, D.; Ishida, K.; Kokubun, J.; Giles, C.; Yokaichiya, F.; Song, C.; Lee, K.B.; Ji, S.; Koo, J.; Park, Y.J.; Kim, J.Y.; Park, J.H.; Shin, H.J.; Rhyee, J.S.; Oh, B.H.; Cho, B.K.; Wilkins Stuart, B.; Paixao, J.A.; Caciuffo, R.; Javorsky, P.; Wastin, F.; Rebizant, J.; Detlefs, C.; Bernheoft, N.; Lander, G.H.; Bombardi, A.; Bergevin, F. de; Matteo, S. di; Paolasini, L.; Rodriguez-Carvajal, J.; Carretta, P.; Millet, P.; Caciuffo, R.; Goff, J.P.; Deen, P.P.; Lee, S.; Stunault, A.; Brown, S.; Mannix, D.; McIntyre, G.J.; Ward, R.C.C.; Wells, M.R.; Lorenzo, J.E.; Joly, Y.; Nazarenko, E.; Staub, U.; Srajer, G.; Haskel, D.; Choi, Y.; Lee, D.R.; Lang, J.C.; Meersschaut, J.; Jiang, J.S.; Bader, S.D.; Bouchenoire, L.; Brown, S.D.; Beesley, A.; Herring, A.; Thomas, M.; Thompson, P.; Langridge, S.; Stirling, W.G.; Mirone, A.; Lander, G.; Wilkins, S.; Ward, R.C.C.; Wells, M.R.; Zochowski, S.W.; Garcia, J.; Subias, G.; Blasco, J.; Sanchez, M.C.; Proietti, M.G.; Lovesey, S.W.; Dmitrienko, V.E.; Ovchinnikova, E.N.; Ishida, K.; Kokubun, J.; Kirfel, A.; Collins, S.P.; Laundy, D.; Oreshko, A.P.; Strange, P.; Horne, M.; Arola, E.; Winter, H.; Szotek, Z.; Temmerman, W.M.; Igarashi, J.; Usuda, M.; Takahashi, M.; Matteo, S. di; Bernhoeft, N.; Hill, J.P.; Lang, J.C.; McWhan, D.; Lee, D.R.; Haskel, D.; Srajer, G.; Hatton Peter, D.; Katsumata, K.; Braithwaite, D

    2004-07-01

    The research field of Resonant X-ray Scattering (RXS) has achieved tremendous progress in the last years. Nowadays RXS is rapidly becoming the crucial technique for investigating the subtleties of microscopic magnetism in systems where the ground state properties reflect a delicate balance between several different correlated processes. The aim of this workshop is to discuss present and future possibilities for RXS investigations of electronic order, including studies of charge, magnetic, and multipolar ordered states. The sessions will cover experimental and theoretical aspects of hard and soft X-ray resonant scattering from single crystals and thin films. This document gathers the summaries of the presentations.

  17. International workshop on resonant X-ray scattering in electrically-ordered systems

    International Nuclear Information System (INIS)

    Collins, S.P.; Pettifer, R.F.; Laundy, D.; Ishida, K.; Kokubun, J.; Giles, C.; Yokaichiya, F.; Song, C.; Lee, K.B.; Ji, S.; Koo, J.; Park, Y.J.; Kim, J.Y.; Park, J.H.; Shin, H.J.; Rhyee, J.S.; Oh, B.H.; Cho, B.K.; Wilkins Stuart, B.; Paixao, J.A.; Caciuffo, R.; Javorsky, P.; Wastin, F.; Rebizant, J.; Detlefs, C.; Bernheoft, N.; Lander, G.H.; Bombardi, A.; Bergevin, F. de; Matteo, S. di; Paolasini, L.; Rodriguez-Carvajal, J.; Carretta, P.; Millet, P.; Caciuffo, R.; Goff, J.P.; Deen, P.P.; Lee, S.; Stunault, A.; Brown, S.; Mannix, D.; McIntyre, G.J.; Ward, R.C.C.; Wells, M.R.; Lorenzo, J.E.; Joly, Y.; Nazarenko, E.; Staub, U.; Srajer, G.; Haskel, D.; Choi, Y.; Lee, D.R.; Lang, J.C.; Meersschaut, J.; Jiang, J.S.; Bader, S.D.; Bouchenoire, L.; Brown, S.D.; Beesley, A.; Herring, A.; Thomas, M.; Thompson, P.; Langridge, S.; Stirling, W.G.; Mirone, A.; Lander, G.; Wilkins, S.; Ward, R.C.C.; Wells, M.R.; Zochowski, S.W.; Garcia, J.; Subias, G.; Blasco, J.; Sanchez, M.C.; Proietti, M.G.; Lovesey, S.W.; Dmitrienko, V.E.; Ovchinnikova, E.N.; Ishida, K.; Kokubun, J.; Kirfel, A.; Collins, S.P.; Laundy, D.; Oreshko, A.P.; Strange, P.; Horne, M.; Arola, E.; Winter, H.; Szotek, Z.; Temmerman, W.M.; Igarashi, J.; Usuda, M.; Takahashi, M.; Matteo, S. di; Bernhoeft, N.; Hill, J.P.; Lang, J.C.; McWhan, D.; Lee, D.R.; Haskel, D.; Srajer, G.; Hatton Peter, D.; Katsumata, K.; Braithwaite, D.

    2004-01-01

    The research field of Resonant X-ray Scattering (RXS) has achieved tremendous progress in the last years. Nowadays RXS is rapidly becoming the crucial technique for investigating the subtleties of microscopic magnetism in systems where the ground state properties reflect a delicate balance between several different correlated processes. The aim of this workshop is to discuss present and future possibilities for RXS investigations of electronic order, including studies of charge, magnetic, and multipolar ordered states. The sessions will cover experimental and theoretical aspects of hard and soft X-ray resonant scattering from single crystals and thin films. This document gathers the summaries of the presentations

  18. Spectral and Timing Nature of the Symbiotic X-Ray Binary 4U 1954+319: The Slowest Rotating Neutron Star in AN X-Ray Binary System

    Science.gov (United States)

    Enoto, Teruaki; Sasano, Makoto; Yamada, Shin'Ya; Tamagawa, Toru; Makishima, Kazuo; Pottschmidt, Katja; Marcu, Diana; Corbet, Robin H. D.; Fuerst, Felix; Wilms, Jorn

    2014-01-01

    The symbiotic X-ray binary (SyXB) 4U 1954+319 is a rare system hosting a peculiar neutron star (NS) and an M-type optical companion. Its approx. 5.4 hr NS spin period is the longest among all known accretion-powered pulsars and exhibited large (is approx. 7%) fluctuations over 8 yr. A spin trend transition was detected with Swift/BAT around an X-ray brightening in 2012. The source was in quiescent and bright states before and after this outburst based on 60 ks Suzaku observations in 2011 and 2012. The observed continuum is well described by a Comptonized model with the addition of a narrow 6.4 keV Fe-K alpha line during the outburst. Spectral similarities to slowly rotating pulsars in high-mass X-ray binaries, its high pulsed fraction (approx. 60%-80%), and the location in the Corbet diagram favor high B-field (approx. greater than 10(exp12) G) over a weak field as in low-mass X-ray binaries. The observed low X-ray luminosity (10(exp33)-10(exp35) erg s(exp-1)), probable wide orbit, and a slow stellar wind of this SyXB make quasi-spherical accretion in the subsonic settling regime a plausible model. Assuming a approx. 10(exp13) G NS, this scheme can explain the approx. 5.4 hr equilibrium rotation without employing the magnetar-like field (approx. 10(exp16) G) required in the disk accretion case. The timescales of multiple irregular flares (approx. 50 s) can also be attributed to the free-fall time from the Alfv´en shell for a approx. 10(exp13) G field. A physical interpretation of SyXBs beyond the canonical binary classifications is discussed.

  19. Relocatable cargo x-ray inspection systems utilizing compact linacs

    International Nuclear Information System (INIS)

    Sapp, W. Wade; Adams, William L.; Callerame, Joseph; Grodzins, Lee; Rothschild, Peter J.; Schueller, Richard; Mishin, Andrey V.; Smith, Gerald J.

    2001-01-01

    Magnetron-powered, X-band linacs with 3-4 MeV capability are compact enough to be readily utilized in relocatable high energy cargo inspection systems. Just such a system is currently under development at AS and E trade mark sign using the commercially available ISOSearch trade mark sign cargo inspection system as the base platform. The architecture permits the retention of backscatter imaging, which has proven to be an extremely valuable complement to the more usual transmission images. The linac and its associated segmented detector will provide an additional view with superior penetration and spatial resolution. The complete system, which is housed in two standard 40 ' ISO containers, is briefly described with emphasis on the installation and operating characteristics of the portable linac. The average rf power delivered by the magnetron to the accelerator section can be varied up to the maximum of about 1 kW. The projected system performance, including radiation dose to the environment, will be discussed and compared with other high energy systems

  20. Design and implemention of a multi-functional x-ray computed tomography system

    Science.gov (United States)

    Li, Lei; Xi, Xiaoqi; Han, Yu; Yan, Bin; Zhang, Xiang; Deng, Lin; Chen, Siyu; Jin, Zhao; Li, Zengguang

    2015-10-01

    A powerful volume X-ray tomography system has been designed and constructed to provide an universal tool for the three-dimensional nondestructive testing and investigation of industrial components, automotive, electronics, aerospace components, new materials, etc. The combined system is equipped with two commercial X-ray sources, sharing one flat panel detector of 400mm×400mm. The standard focus 450kV high-energy x-ray source is optimized for complex and high density components such as castings, engine blocks and turbine blades. And the microfocus 225kV x-ray source is to meet the demands of micro-resolution characterization applications. Thus the system's penetration capability allows to scan large objects up to 200mm thick dense materials, and the resolution capability can meet the demands of 20μm microstructure inspection. A high precision 6-axis manipulator system is fitted, capable of offset scanning mode in large field of view requirements. All the components are housed in a room with barium sulphate cement. On the other hand, the presented system expands the scope of applications such as dual energy research and testing. In this paper, the design and implemention of the flexible system is described, as well as the preliminary tomographic imaging results of an automobile engine block.

  1. A new detector system for low energy X-ray fluorescence coupled with soft X-ray microscopy: First tests and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Gianoncelli, Alessandra, E-mail: alessandra.gianoncelli@elettra.eu [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Bufon, Jernej [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); University of Trieste, Piazzale Europa 1, Trieste 34127 (Italy); Ahangarianabhari, Mahdi [Politecnico di Milano, Via Anzani 42, Como 22100 (Italy); INFN Milano, Via Celoria 16, Milano 20133 (Italy); Altissimo, Matteo [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Bellutti, Pierluigi [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Bertuccio, Giuseppe [Politecnico di Milano, Via Anzani 42, Como 22100 (Italy); INFN Milano, Via Celoria 16, Milano 20133 (Italy); Borghes, Roberto [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Carrato, Sergio [University of Trieste, Piazzale Europa 1, Trieste 34127 (Italy); Cautero, Giuseppe [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Fabiani, Sergio [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Giacomini, Gabriele [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Giuressi, Dario [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Kourousias, George [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Menk, Ralf Hendrik [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Picciotto, Antonino; Piemonte, Claudio [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Rachevski, Alexandre [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); and others

    2016-04-21

    The last decades have witnessed substantial efforts in the development of several detector technologies for X-ray fluorescence (XRF) applications. In spite of the increasing trend towards performing, cost-effective and reliable XRF systems, detectors for soft X-ray spectroscopy still remain a challenge, requiring further study, engineering and customization in order to yield effective and efficient systems. In this paper we report on the development, first characterization and tests of a novel multielement detector system based on low leakage current silicon drift detectors (SDD) coupled to ultra low noise custom CMOS preamplifiers for synchrotron-based low energy XRF. This new system exhibits the potential for improving the count rate by at least an order of magnitude resulting in ten-fold shorter dwell time at an energy resolution similar to that of single element silicon drift detectors.

  2. Gamma, x-ray reduction system. Volume I: gamma

    International Nuclear Information System (INIS)

    Zimmer, W.H.

    1976-01-01

    The starting premises for this data reduction system were (a) the individual researcher needs all the accuracy that can be achieved but he has neither the time nor the inclination to learn how to achieve it, and (b) if the data reduction system is to be centralized the people operating it will want to minimize conversation with the computer. This is a working system. All spectral data are stored on Data General 4234 discs after background normalization and strip. Storage is initiated from magnetic tapes loaded by detached pulse height analyzers or directly from Scorpio pulse height analyzers. The only restrictions placed on the individual researchers are that the pulse height analyzer energy scale be set up consistently, that a recovery standard be run at least once every day of use, and the total acquisition system be calibrated to its range of use. In many instances, and if desirable, the latter is provided as a service. At the time of writing this gamma data reduction system is actively being used to calculate net peak areas, activities with or without time correction, activations analysis results, counting precisions, and dynamic limits of detection for the spectral data output of 17 detached pulse height analyzers. To all modes of data reduction are applied background subtraction, random summing correction, detector recovery factor correction, peak interfernce correction (second-order product interference for activation analysis), geometry function correction, acquisition time decay corrections, external and internal sorber correction. All of this is accomplished and a customer report typed in a readable format after a halfline of noninteractive instruction

  3. Computerized method for X-ray angular distribution simulation in radiological systems

    International Nuclear Information System (INIS)

    Marques, Marcio A.; Oliveira, Henrique J.Q. de; Frere, Annie F.; Schiabel, Homero; Marques, Paulo M.A.

    1996-01-01

    A method to simulate the changes in X-ray angular distribution (the Heel effect) for radiologic imaging systems is presented. This simulation method is described as to predict images for any exposure technique considering that the distribution is the cause of the intensity variation along the radiation field

  4. Addressing source-induced structural vibrations in an interventional X-ray system

    NARCIS (Netherlands)

    Van Pinxteren, J.A.W.; Vermeulen, J.P.M.B.; van Loon, R.J.A.; van Schothorst, G.; Billington, D.; Phillips, D.

    2017-01-01

    Interventional radiology is a medical discipline, in which imaging equipment is used to diagnose and treat diseases throughout the human body. Dedicated systems, based on X-ray, computed tomography and ultrasound technology, allow for 2D and 3D imaging of (contrast enhanced) physical structures.

  5. Si(Li) detector system for application to x-ray astronomy rocket experiments

    International Nuclear Information System (INIS)

    Griffiths, R.E.; Cheron, C.; Friant, A.; Jehanno, C.; Rocchia, R.; Rothenflug, R.; Testard, O.

    1975-01-01

    The problems associated with the use of Si(Li) detectors in x-ray astronomy rocket experiments are discussed. In particular a detector system is described that can be used at the focus of a grazing-incidence paraboloid telescope for the energy range 0.3 to 2 keV. (U.S.)

  6. X-ray excited optical luminescence studies on the system BaXY (X ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 65; Issue 2. X-ray excited optical luminescence studies on the system Ba (, =F, Cl, Br, I) ... India; Department of Chemical Engineering, National Taiwan University, Republic of China ... Proceedings of the International Workshop/Conference on Computational ...

  7. Resonant soft x-ray scattering and charge density waves in correlated systems

    NARCIS (Netherlands)

    Rusydi, Andrivo

    2006-01-01

    Summary This work describes results obtained on the study of charge density waves (CDW) in strongly correlated systems with a new experimental method: resonant soft x-ray scattering (RSXS). The basic motivation is the 1986 discovery by Bednorz and Müler of a new type of superconductor, based on Cu

  8. High Energy X-Ray System Specification for the Device Assembly Facility (DAF) at the NNSS

    International Nuclear Information System (INIS)

    Fry, David A.

    2012-01-01

    This specification establishes requirements for an X-Ray System to be used at the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS) to support radiography of experimental assemblies for Laboratory (LANL, LLNL, SNL) programs conducting work at the NNSS.

  9. Spectral information interpretation of X-ray analysis based on expert system approach

    International Nuclear Information System (INIS)

    Drakunov, Yu.M.; Lezin, A.N.; Pukha, N.P.; Silachev, I.Yu.

    2000-01-01

    An expert subprogram for automated identification for element composition of the samples of different nature according to the result of energy-dispersive X-ray fluorescence analysis is elaborated, The flowchart of the subprogram is presented, brief description of expert system structure and its algorithm is given. (author)

  10. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Rosado, P.H.G.; Cunha, P.G. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  11. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    Science.gov (United States)

    Guimarães, M. C.; Silva, C. R. E.; Rosado, P. H. G.; Cunha, P. G.; Da Silva, T. A.

    2018-03-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work.

  12. Reliability of an x-ray system for calibrating and testing personal radiation dosimeters

    International Nuclear Information System (INIS)

    Guimarães, M.C.; Silva, C.R.E.; Silva, T.A. da; Rosado, P.H.G.; Cunha, P.G.

    2017-01-01

    Metrology laboratories are expected to maintain standardized radiation beams and traceable standard dosimeters to provide reliable calibrations or testing of detectors. Results of the characterization of an x-ray system for performing calibration and testing of radiation dosimeters used for individual monitoring are shown in this work. (author)

  13. X-ray and gamma ray detector readout system

    Science.gov (United States)

    Tumer, Tumay O; Clajus, Martin; Visser, Gerard

    2010-10-19

    A readout electronics scheme is under development for high resolution, compact PET (positron emission tomography) imagers based on LSO (lutetium ortho-oxysilicate, Lu.sub.2SiO.sub.5) scintillator and avalanche photodiode (APD) arrays. The key is to obtain sufficient timing and energy resolution at a low power level, less than about 30 mW per channel, including all required functions. To this end, a simple leading edge level crossing discriminator is used, in combination with a transimpedance preamplifier. The APD used has a gain of order 1,000, and an output noise current of several pA/ Hz, allowing bipolar technology to be used instead of CMOS, for increased speed and power efficiency. A prototype of the preamplifier and discriminator has been constructed, achieving timing resolution of 1.5 ns FWHM, 2.7 ns full width at one tenth maximum, relative to an LSO/PMT detector, and an energy resolution of 13.6% FWHM at 511 keV, while operating at a power level of 22 mW per channel. Work is in progress towards integration of this preamplifier and discriminator with appropriate coincidence logic and amplitude measurement circuits in an ASIC suitable for a high resolution compact PET instrument. The detector system and/or ASIC can also be used for many other applications for medical to industrial imaging.

  14. A hyperspectral X-ray computed tomography system for enhanced material identification

    Science.gov (United States)

    Wu, Xiaomei; Wang, Qian; Ma, Jinlei; Zhang, Wei; Li, Po; Fang, Zheng

    2017-08-01

    X-ray computed tomography (CT) can distinguish different materials according to their absorption characteristics. The hyperspectral X-ray CT (HXCT) system proposed in the present work reconstructs each voxel according to its X-ray absorption spectral characteristics. In contrast to a dual-energy or multi-energy CT system, HXCT employs cadmium telluride (CdTe) as the x-ray detector, which provides higher spectral resolution and separate spectral lines according to the material's photon-counter working principle. In this paper, a specimen containing ten different polymer materials randomly arranged was adopted for material identification by HXCT. The filtered back-projection algorithm was applied for image and spectral reconstruction. The first step was to sort the individual material components of the specimen according to their cross-sectional image intensity. The second step was to classify materials with similar intensities according to their reconstructed spectral characteristics. The results demonstrated the feasibility of the proposed material identification process and indicated that the proposed HXCT system has good prospects for a wide range of biomedical and industrial nondestructive testing applications.

  15. Development of X-ray CCD camera system with high readout rate using ASIC

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Matsuura, Daisuke; Anabuki, Naohisa; Miyata, Emi; Tsunemi, Hiroshi; Doty, John P.; Ikeda, Hirokazu; Katayama, Haruyoshi

    2009-01-01

    We report on the development of an X-ray charge-coupled device (CCD) camera system with high readout rate using application-specific integrated circuit (ASIC) and Camera Link standard. The distinctive ΔΣ type analog-to-digital converter is introduced into the chip to achieve effective noise shaping and to obtain a high resolution with relatively simple circuits. The unit test proved moderately low equivalent input noise of 70μV with a high readout pixel rate of 625 kHz, while the entire chip consumes only 100 mW. The Camera Link standard was applied for the connectivity between the camera system and frame grabbers. In the initial test of the whole system, we adopted a P-channel CCD with a thick depletion layer developed for X-ray CCD camera onboard the next Japanese X-ray astronomical satellite. The characteristic X-rays from 109 Cd were successfully read out resulting in the energy resolution of 379(±7)eV (FWHM) at 22.1 keV, that is, ΔE/E=1.7% with a readout rate of 44 kHz.

  16. Planetary Protection: X-ray Super-Flares Aid Formation of "Solar Systems"

    Science.gov (United States)

    2005-05-01

    New results from NASA's Chandra X-ray Observatory imply that X-ray super-flares torched the young Solar System. Such flares likely affected the planet-forming disk around the early Sun, and may have enhanced the survival chances of Earth. By focusing on the Orion Nebula almost continuously for 13 days, a team of scientists used Chandra to obtain the deepest X-ray observation ever taken of this or any star cluster. The Orion Nebula is the nearest rich stellar nursery, located just 1,500 light years away. These data provide an unparalleled view of 1400 young stars, 30 of which are prototypes of the early Sun. The scientists discovered that these young suns erupt in enormous flares that dwarf - in energy, size, and frequency -- anything seen from the Sun today. Illustration of Large Flares Illustration of Large Flares "We don't have a time machine to see how the young Sun behaved, but the next best thing is to observe Sun-like stars in Orion," said Scott Wolk of Harvard-Smithsonian Center for Astrophysics in Cambridge, Mass. "We are getting a unique look at stars between one and 10 million years old - a time when planets form." A key result is that the more violent stars produce flares that are a hundred times as energetic as the more docile ones. This difference may specifically affect the fate of planets that are relatively small and rocky, like the Earth. "Big X-ray flares could lead to planetary systems like ours where Earth is a safe distance from the Sun," said Eric Feigelson of Penn State University in University Park, and principal investigator for the international Chandra Orion Ultradeep Project. "Stars with smaller flares, on the other hand, might end up with Earth-like planets plummeting into the star." Animation of X-ray Flares from a Young Sun Animation of X-ray Flares from a "Young Sun" According to recent theoretical work, X-ray flares can create turbulence when they strike planet-forming disks, and this affects the position of rocky planets as they

  17. X-ray diagnostics for TFTR

    International Nuclear Information System (INIS)

    von Goeler, S.; Hill, K.W.; Bitter, M.

    1982-12-01

    A short description of the x-ray diagnostic preparation for the TFTR tokamak is given. The x-ray equipment consists of the limiter x-ray monitoring system, the soft x-ray pulse-height-analysis-system, the soft x-ray imaging system and the x-ray crystal spectrometer. Particular attention is given to the radiation protection of the x-ray systems from the neutron environment

  18. Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums

    International Nuclear Information System (INIS)

    Park, Jong Kil; Maeng, Seong Jun; Lee, Yeon Ee; Hwang, Tae Won

    2008-01-01

    The physical and chemical properties of radioactive waste drums, which have been temporarily stored on site, should be characterized before their shipment to a disposal facility in order to prove that the properties meet the acceptance guideline. The investigation of NDT(Nondestructive Test) method was figured out that the contents in drum, the quantitative analysis of free standing water and void fraction can be examined with X-ray NDT techniques. This paper describes the characteristics of X-ray NDT such as its principles, the considerations for selection of X-ray system, etc. And then, the waste drum characteristics such as drum type and dimension, contents in drum, etc. were examined, which are necessary to estimate the optimal X-ray energy for NDT of a drum. The estimation results were that: the proper X-ray energy is under 3 MeV to test the drums of 320 β and less; both X-ray systems of 450 keV and/or 3 MeV might be needed considering the economical efficiency and the realization. The number of drums that can be tested with 450 keV and 3 MeV X-ray system was figured out as 42,327 and 18,105 drums (based on storage of 2006. 12), respectively. Four testing scenarios were derived considering equipment procurement method, outsourcing or not, etc. The economical and feasibility assessment for the scenarios was resulted in that an optimal scenario is dependent on the acceptance guide line, the waste generator's policy on the waste treatment and the delivery to a disposal facility, etc. For example, it might be desirable that a waste generator purchases two 450 keV mobile system to examine the drums containing low density waste, and that outsourcing examination for the high density drums, if all NDT items such as quantitative analysis for 'free standing water' and 'void fraction', and confirmation of contents in drum have to be characterized. However, one 450 keV mobile system seems to be required to test only the contents in 13,000 drums per year.

  19. Promoting radiation protection and safety for X-ray inspection systems

    International Nuclear Information System (INIS)

    Maharaj, Harri P.

    2008-01-01

    This paper aims to present a regulatory perspective on radiation protection and safety relevant to facilities utilizing baggage X-ray inspection systems. Over the past several years there has been rapid growth in the acquisition and utilization of X-ray tube based inspection systems for security screening purposes worldwide. In addition to ensuring compliance with prescribed standards applicable to such X-ray systems, facilities subject to federal jurisdiction in Canada are required to comply with established codes of practice, which, not only are in accordance with occupational health and safety legislation but also are consistent with international guidance. Overall, these measures are aimed at reducing radiation risks and adverse health effects. Data, acquired in the past several years in a number of facilities through various instruments, namely, monitoring and surveillance, radiation safety audits, onsite evaluations, device registration processes and information developed, were considered in conjunction with detrimental traits. Changes are necessary to reduce radiation and safety risks from both an ALARA point of view and an accountability perspective. Establishing, developing, implementing and following a radiation protection program is warranted and advocated. Minimally, such a program shall be managed by a radiation safety officer. It shall promote and sustain a radiation safety culture in the workplace; shall ensure properly qualified individuals operate and service the X-ray systems in accordance with established and authorized procedures; and shall incorporate data recording and life cycle management principles. Such a program should be the norm for a facility that utilizes baggage X-ray inspection systems for security purposes, and it shall be subject to continuous regulatory oversight. (author)

  20. X-ray investigation of intermetallides and their hydrides under hydrogen pressure in H2-LaNi5 system

    International Nuclear Information System (INIS)

    Karonik, V.V.; Tsypin, M.I.; Prokof'ev, M.V.; Kazakov, D.N.

    1983-01-01

    X-ray phase analysis has been used to investigate phase composition of LaNi 5 -H 2 system; comparison of X-ray diffraction data with the results of plotting absorption and desorption isotherms is conducted. Technique of the X-ray diffraction study of intermetallide-hydrogen system using special X-ray chamber to diffractometer DRON-1.5 (GUR-5) is worked out. The parameters of elementary cell of the LaNisub(5)Hsub(6.2) hydride are determined: a=0.541(2) pm, c=0.430(2) nm, c/a=0.795, V=0.109 nm 3 (hexagonal syngony)

  1. The design of management system guidelines and technical standards for the production of x-ray aircraft

    International Nuclear Information System (INIS)

    Dyah Palupi; Made Pramayuni

    2013-01-01

    Concept of management systems guidelines and technical standards X-ray Equipment Production arranged in order to prepare for the effective and efficient regulatory to ensure the safety of X-ray equipment production in Indonesia. The regulatory tools may the government policy or regulations. Authors proposed that BAPETEN develop guidelines for management system of x-ray equipment production by combining ISO 13485 with BAPETEN Chairman Regulation no.4 /2010. Author also suggested that BAPETEN make technical standards IEC 60601 as a mandatory standard in producing x-ray equipment. (author)

  2. Modeling of finite systems irradiated by intense ultrashort hard X-ray pulses

    Energy Technology Data Exchange (ETDEWEB)

    Jurek, Zoltan [Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22607 Hamburg (Germany); Ziaja, Beata [Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22607 Hamburg (Germany); Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Krakow (Poland); Santra, Robin [Center for Free-Electron Laser Science, Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22607 Hamburg (Germany); Department of Physics, University of Hamburg, Jungiusstrasse 9, 20355 Hamburg (Germany)

    2013-07-01

    Large number of experiments have already been carried out at the existing hard X-Ray Free-Electron Laser facilities (LCLS, SACLA) during the recent years. Their great success generates even higher anticipation for the forthcoming X-ray sources (European XFEL). Single molecule imaging and nanoplasma formation are the challenging projects with XFELs that investigate the interaction of finite, small objects, e.g. single molecules, atomic clusters with intense X-ray radiation. Accurate modelling of the time evolution of such irradiated systems is required in order to understand the current experiments and to inspire new directions of experimental investigation. In this presentation we report on our theoretical molecular-dynamics tool able to follow non-equilibrium dynamics within finite systems irradiated by intense X-ray pulses. We introduce the relevant physical processes, present computational methods used, discuss their limitations and also the specific constraints on calculations imposed by experimental conditions. Finally, we conclude with a few simulation examples.

  3. Quasi-simultaneous observations of BL Lac object Mrk 501 in X-ray, UV, visible, IR, and radio frequencies

    International Nuclear Information System (INIS)

    Kondo, Y.; Worrall, D.M.; Mushotzky, R.F.; Hackney, R.L.; Hackney, K.R.H.; Oke, J.B.; Yee, H.K.C.; Neugebauer, G.; Matthews, K.; Feldman, P.A.; Brown, R.L.

    1981-01-01

    Quasi-simultaneous observations of the BL Lac object Mrk 501 were performed for the first time at X-ray, ultraviolet, visible infrared, and radio frequencies. As the BL Lac objects are known to vary in their flux, such a ''quasi-instantaneous'' spectral energy profile is necessary in order to describe properly the energy generation mechanism. The observed spectral slope from the X-ray to UV regions is positive and continuous, but that from the mid-UV to visible light region becomes gradually flat and possibly turns down toward lower frequencies; the optical-radio emission cannot be accounted for by a single power law. Several theoretical models have been considered for the emission mechanism. In some cases quantitative comparison with the data is not practical. However, most of the models are, at least, not inconsistent with the observations. A quantitative comparison has been peformed with the synchroton self-Compton model; the total spectrum is found consistent with this model. The spectrum from visible light to X-ray is consistent with synchrotron radiation or with inverse-Compton scattering by a hot thermal cloud of electrons. The continuity of the spectral slope from X-ray to UV implied by the current data suggests that the previous estimates of the total luminosity of this BL Lac object has been underestimated by a factor of about 3 or 4

  4. XAssist: A System for the Automation of X-ray Astrophysics Analysis

    Science.gov (United States)

    Ptak, A.

    2004-08-01

    XAssist is a NASA AISR-funded project for the automation of X-ray astrophysics. It is capable of data reprocessing, source detection, and preliminary spatial, temporal and spectral analysis for each source with sufficient counts. The bulk of the system is written in Python, which in turn drives underlying software (CIAO for Chandra data, etc.). Future work will include a GUI (mainly for beginners and status monitoring) and the exposure of at least some functionality as web services. The latter will help XAssist to eventually become part of the VO, making advanced queries possible, such as determining the X-ray fluxes of counterparts to HST or SDSS sources (including the use of unpublished X-ray data), and add the ability of ``on-the-fly'' X-ray processing. Pipelines are running on Chandra and XMM-Newton observations of galaxies to demonstrate XAssist's capabilities, and the results are available online (in real time) at http://www.xassist.org. XAssist itself as well as various associated projects are available for download.

  5. Cascaded systems analysis of charge sharing in cadmium telluride photon-counting x-ray detectors.

    Science.gov (United States)

    Tanguay, Jesse; Cunningham, Ian A

    2018-05-01

    Single-photon-counting (SPC) and spectroscopic x-ray detectors are under development in academic and industry laboratories for medical imaging applications. The spatial resolution of SPC and spectroscopic x-ray detectors is an important design criterion. The purpose of this article was to extend the cascaded systems approach to include a description of the spatial resolution of SPC and spectroscopic x-ray imaging detectors. A cascaded systems approach was used to model reabsorption of characteristic x rays, Coulomb repulsion, and diffusion in SPC and spectroscopic x-ray detectors. In addition to reabsorption, diffusion, and Coulomb repulsion, the model accounted for x-ray conversion to electron-hole (e-h) pairs, integration of e-h pairs in detector elements, electronic noise, and energy thresholding. The probability density function (PDF) describing the number of e-h pairs was propagated through each stage of the model and was used to derive new theoretical expressions for the large-area gain and modulation transfer function (MTF) of CdTe SPC x-ray detectors, and the energy bin sensitivity functions and MTFs of CdTe spectroscopic detectors. Theoretical predictions were compared with the results of MATLAB-based Monte Carlo (MC) simulations and published data. Comparisons were also made with the MTF of energy-integrating systems. Under general radiographic conditions, reabsorption, diffusion, and Coulomb repulsion together artificially inflate count rates by 20% to 50%. For thicker converters (e.g. 1000 μm) and larger detector elements (e.g. 500 μm pixel pitch) these processes result in modest inflation (i.e. ∼10%) in apparent count rates. Our theoretical and MC analyses predict that SPC MTFs will be degraded relative to those of energy-integrating systems for fluoroscopic, general radiographic, and CT imaging conditions. In most cases, this degradation is modest (i.e., ∼10% at the Nyquist frequency). However, for thicker converters, the SPC MTF can be degraded

  6. X-ray quality increasing system controlled by single-chip microcomputer in single phase fluoroscopy unit

    International Nuclear Information System (INIS)

    Wang Qiaolin; Gu Hongmei

    2004-01-01

    Objective: To decrease the amount of radiation that doctor and patient receives by increasing X-ray quality. Methods: Using Single-chip Microcomputer technology, test and modulate AC(Alternating Current) from high voltage generator by IGBT. X-ray tube generates X-rays only at high energy area. Thus the amount of radiation decreases. Results: The tube current decreases remarkably and the amount of radiation that doctor and patient receives decreases effectively. Conclusion: the system can effectively decrease the amount of radiation and is widely applicable to the upgrade of all kinds of single phase X-ray units. (authors)

  7. Coded diffraction system in X-ray crystallography using a boolean phase coded aperture approximation

    Science.gov (United States)

    Pinilla, Samuel; Poveda, Juan; Arguello, Henry

    2018-03-01

    Phase retrieval is a problem present in many applications such as optics, astronomical imaging, computational biology and X-ray crystallography. Recent work has shown that the phase can be better recovered when the acquisition architecture includes a coded aperture, which modulates the signal before diffraction, such that the underlying signal is recovered from coded diffraction patterns. Moreover, this type of modulation effect, before the diffraction operation, can be obtained using a phase coded aperture, just after the sample under study. However, a practical implementation of a phase coded aperture in an X-ray application is not feasible, because it is computationally modeled as a matrix with complex entries which requires changing the phase of the diffracted beams. In fact, changing the phase implies finding a material that allows to deviate the direction of an X-ray beam, which can considerably increase the implementation costs. Hence, this paper describes a low cost coded X-ray diffraction system based on block-unblock coded apertures that enables phase reconstruction. The proposed system approximates the phase coded aperture with a block-unblock coded aperture by using the detour-phase method. Moreover, the SAXS/WAXS X-ray crystallography software was used to simulate the diffraction patterns of a real crystal structure called Rhombic Dodecahedron. Additionally, several simulations were carried out to analyze the performance of block-unblock approximations in recovering the phase, using the simulated diffraction patterns. Furthermore, the quality of the reconstructions was measured in terms of the Peak Signal to Noise Ratio (PSNR). Results show that the performance of the block-unblock phase coded apertures approximation decreases at most 12.5% compared with the phase coded apertures. Moreover, the quality of the reconstructions using the boolean approximations is up to 2.5 dB of PSNR less with respect to the phase coded aperture reconstructions.

  8. Measurement of the energy distribution of parametric X-ray radiation from a double-crystal system

    International Nuclear Information System (INIS)

    Mori, Akira; Hayakawa, Yasushi; Kidokoro, Akio; Sato, Isamu; Tanaka, Toshinari; Hayakawa, Ken; Kobayashi, Kouji; Ohshima, Hisashi

    2006-01-01

    A parametric X-ray radiation (PXR) generator system was developed at the Laboratory for Electron Beam Research and Applications (LEBRA) at Nihon University; this PXR generator system is a tunable wavelength and quasi-monochromatic X-ray source constructed as one of the advanced applications of the LEBRA 125-MeV electron linear accelerator. The PXR beam which has characteristic of energy distribution. The theoretical values of energy distribution obtained at the output port were calculated to be approximately 300 eV and 2 keV at the central X-ray energies of 7 keV and 20 keV, respectively. In order to investigate the energy distribution, several measurements of the X-ray energy were carried out. The X-ray absorption of known materials and that of thin aluminum has been evaluated based on analyses of images taken using an imaging plate. The X-ray energy was deduced base on the identification of the absorption edges, and the energy distribution was estimated based on measurements using aluminum step method. In addition, an X-ray diffraction method using a perfect silicon crystal was employed, and spectra were measured using a solid state detector (SSD). The results of these experiments agreed with the calculated results. In particular, the well-defined absorption edges in the X-ray images and the typical rocking curves obtained by the measurement of the X-ray diffraction indicated that the distribution has a high-energy resolution

  9. Real time global orbit feedback system for NSLS x-ray ring

    International Nuclear Information System (INIS)

    Yu, L.H.; Biscardi, R.; Bittner, J.; Fauchet, A.M.; Krinsky, F.S.; Nawrocky, R.J.; Rothman, J.; Singh, O.V.; Yang, K.M.

    1991-01-01

    We report on the design and commissioning of a real time harmonic global orbit feedback system for the NSLS X-ray ring. This system uses 8 pick-up electrode position monitors and 16 trim dipole magnets to eliminate 3 harmonic components of the orbit fluctuations. Because of the larger number of position monitors and trim magnets, the X-ray ring feedback system differs from the previously reported VUV ring system in that the Fourier analysis and harmonic generation networks are comprised of MDAC boards controlled by computer. The implementation of the global feedback system has resulted in a dramatic improvement of orbit stability, by more than a factor of five everywhere. Simultaneous operation of the global and several local bump feedback systems has been achieved. 4 refs., 5 figs

  10. Cross-correlating Cosmic IR and X-ray Background Fluctuations: Evidence of Significant Black Hole Populations Among the CIB Sources

    Science.gov (United States)

    Cappelluti, N.; Kashlinsky, A.; Arendt, R. G.; Comastri, A.; Fazio, G. G.; Finoguenov, A.; Hasinger, G.; Mather, J. C.; Miyaji, T; Moseley, S. H.

    2013-01-01

    In order to understand the nature of the sources producing the recently uncovered cosmic infrared background (CIB) fluctuations, we study cross-correlations between the fluctuations in the source-subtracted CIB from Spitzer/IRAC data and the unresolved cosmic X-ray background from deep Chandra observations. Our study uses data from the EGS/AEGIS field, where both data sets cover an approx = 8' x 45' region of the sky. Our measurement is the cross-power spectrum between the IR and X-ray data. The cross-power signal between the IRAC maps at 3.6 micron and 4.5 micron and the Chandra [0.5-2] keV data has been detected, at angular scales approx >20'', with an overall significance of approx = 3.8 sigma and approx. = 5.6 sigma, respectively. At the same time we find no evidence of significant cross-correlations at the harder Chandra bands. The cross-correlation signal is produced by individual IR sources with 3.6 micron and 4.5 micron magnitudes m(sub AB) approx. > 25-26 and [0.5-2] keV X-ray fluxes black holes than among the known populations. We discuss the various possible origins for the cross-power signal and show that neither local foregrounds nor the known remaining normal galaxies and active galactic nuclei can reproduce the measurements. These observational results are an important new constraint on theoretical modeling of the near-IR CIB fluctuations. local foregrounds, nor the known remaining normal galaxies and active galactic nuclei (AGN) can reproduce the measurements. These observational results are an important new constraint on theoretical modeling of the near-IR CIB fluctuations

  11. DISCOVERY OF X-RAY EMISSION FROM THE FIRST Be/BLACK HOLE SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Munar-Adrover, P.; Paredes, J. M.; Ribó, M. [Departament d' Astronomia i Meteorologia, Institut de Ciències del Cosmos, Universitat de Barcelona, IEEC-UB, Martí i Franquès 1, E-08028 Barcelona (Spain); Iwasawa, K. [ICREA, Institut de Ciències del Cosmos, Universitat de Barcelona, IEEC-UB, Martí i Franquès 1, E-08028 Barcelona (Spain); Zabalza, V. [Department of Physics and Astronomy, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Casares, J. [Instituto de Astrofísica de Canarias, E-38200 La Laguna, Tenerife (Spain)

    2014-05-10

    MWC 656 (=HD 215227) was recently discovered to be the first binary system composed of a Be star and a black hole (BH). We observed it with XMM-Newton, and detected a faint X-ray source compatible with the position of the optical star, thus proving it to be the first Be/BH X-ray binary. The spectrum analysis requires a model fit with two components, a blackbody plus a power law, with k{sub B}T=0.07{sub −0.03}{sup +0.04} keV and a photon index Γ = 1.0 ± 0.8, respectively. The non-thermal component dominates above ≅0.8 keV. The obtained total flux is F(0.3-5.5 keV)=(4.6{sub −1.1}{sup +1.3})×10{sup −14} erg cm{sup –2} s{sup –1}. At a distance of 2.6 ± 0.6 kpc the total flux translates into a luminosity L {sub X} = (3.7 ± 1.7) × 10{sup 31} erg s{sup –1}. Considering the estimated range of BH masses to be 3.8-6.9 M {sub ☉}, this luminosity represents (6.7 ± 4.4) × 10{sup –8} L {sub Edd}, which is typical of stellar-mass BHs in quiescence. We discuss the origin of the two spectral components: the thermal component is associated with the hot wind of the Be star, whereas the power-law component is associated with emission from the vicinity of the BH. We also find that the position of MWC 656 in the radio versus X-ray luminosity diagram may be consistent with the radio/X-ray correlation observed in BH low-mass X-ray binaries. This suggests that this correlation might also be valid for BH high-mass X-ray binaries (HMXBs) with X-ray luminosities down to ∼10{sup –8} L {sub Edd}. MWC 656 will allow the accretion processes and the accretion/ejection coupling at very low luminosities for BH HMXBs to be studied.

  12. Catalysis of GTP hydrolysis by small GTPases at atomic detail by integration of X-ray crystallography, experimental, and theoretical IR spectroscopy.

    Science.gov (United States)

    Rudack, Till; Jenrich, Sarah; Brucker, Sven; Vetter, Ingrid R; Gerwert, Klaus; Kötting, Carsten

    2015-10-02

    Small GTPases regulate key processes in cells. Malfunction of their GTPase reaction by mutations is involved in severe diseases. Here, we compare the GTPase reaction of the slower hydrolyzing GTPase Ran with Ras. By combination of time-resolved FTIR difference spectroscopy and QM/MM simulations we elucidate that the Mg(2+) coordination by the phosphate groups, which varies largely among the x-ray structures, is the same for Ran and Ras. A new x-ray structure of a Ran·RanBD1 complex with improved resolution confirmed this finding and revealed a general problem with the refinement of Mg(2+) in GTPases. The Mg(2+) coordination is not responsible for the much slower GTPase reaction of Ran. Instead, the location of the Tyr-39 side chain of Ran between the γ-phosphate and Gln-69 prevents the optimal positioning of the attacking water molecule by the Gln-69 relative to the γ-phosphate. This is confirmed in the RanY39A·RanBD1 crystal structure. The QM/MM simulations provide IR spectra of the catalytic center, which agree very nicely with the experimental ones. The combination of both methods can correlate spectra with structure at atomic detail. For example the FTIR difference spectra of RasA18T and RanT25A mutants show that spectral differences are mainly due to the hydrogen bond of Thr-25 to the α-phosphate in Ran. By integration of x-ray structure analysis, experimental, and theoretical IR spectroscopy the catalytic center of the x-ray structural models are further refined to sub-Å resolution, allowing an improved understanding of catalysis. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  13. Catalysis of GTP Hydrolysis by Small GTPases at Atomic Detail by Integration of X-ray Crystallography, Experimental, and Theoretical IR Spectroscopy*

    Science.gov (United States)

    Rudack, Till; Jenrich, Sarah; Brucker, Sven; Vetter, Ingrid R.; Gerwert, Klaus; Kötting, Carsten

    2015-01-01

    Small GTPases regulate key processes in cells. Malfunction of their GTPase reaction by mutations is involved in severe diseases. Here, we compare the GTPase reaction of the slower hydrolyzing GTPase Ran with Ras. By combination of time-resolved FTIR difference spectroscopy and QM/MM simulations we elucidate that the Mg2+ coordination by the phosphate groups, which varies largely among the x-ray structures, is the same for Ran and Ras. A new x-ray structure of a Ran·RanBD1 complex with improved resolution confirmed this finding and revealed a general problem with the refinement of Mg2+ in GTPases. The Mg2+ coordination is not responsible for the much slower GTPase reaction of Ran. Instead, the location of the Tyr-39 side chain of Ran between the γ-phosphate and Gln-69 prevents the optimal positioning of the attacking water molecule by the Gln-69 relative to the γ-phosphate. This is confirmed in the RanY39A·RanBD1 crystal structure. The QM/MM simulations provide IR spectra of the catalytic center, which agree very nicely with the experimental ones. The combination of both methods can correlate spectra with structure at atomic detail. For example the FTIR difference spectra of RasA18T and RanT25A mutants show that spectral differences are mainly due to the hydrogen bond of Thr-25 to the α-phosphate in Ran. By integration of x-ray structure analysis, experimental, and theoretical IR spectroscopy the catalytic center of the x-ray structural models are further refined to sub-Å resolution, allowing an improved understanding of catalysis. PMID:26272610

  14. Review of vacuum systems for x-ray lithography light sources

    International Nuclear Information System (INIS)

    Schuchman, J.C.

    1990-01-01

    This paper will review and give a status report on vacuum systems for X-Ray lithography light sources. It will include conventional machines and compact machines (machines using superconducting magnets). The vacuum systems will be described and compared with regard to basic machine parameters, pumping systems, types of pumps, chamber design and material, gauging and diagnostics, and machine performane. 23 refs., 8 figs., 1 tab

  15. Design of scanning motion control system for high-energy X-ray industrial CT

    International Nuclear Information System (INIS)

    Duan Liming

    2008-01-01

    A scanning motion control system was developed for the high-energy X-ray industrial computerized tomography (CT). The system consists of an industrial control computer, a counter card, a control card, servo drivers, servo motors, working platforms, gratings and control software. Based on windows driver model(WDM) mode, the composition of the driver pro- gram for the system was studied. Took the motor control card as an example, the method to develop the driver program was researched, and the intercourse process between the device driver program and the user-program was analyzed. The real-time control of the system was implemented using the WDM driver. The real-time performance and reliability of the system can satisfy the requirement of high-energy X-ray industrial CT. (authors)

  16. Nondestructive strain depth profiling with high energy X-ray diffraction: System capabilities and limitations

    Science.gov (United States)

    Zhang, Zhan; Wendt, Scott; Cosentino, Nicholas; Bond, Leonard J.

    2018-04-01

    Limited by photon energy, and penetration capability, traditional X-ray diffraction (XRD) strain measurements are only capable of achieving a few microns depth due to the use of copper (Cu Kα1) or molybdenum (Mo Kα1) characteristic radiation. For deeper strain depth profiling, destructive methods are commonly necessary to access layers of interest by removing material. To investigate deeper depth profiles nondestructively, a laboratory bench-top high-energy X-ray diffraction (HEXRD) system was previously developed. This HEXRD method uses an industrial 320 kVp X-Ray tube and the Kα1 characteristic peak of tungsten, to produces a higher intensity X-ray beam which enables depth profiling measurement of lattice strain. An aluminum sample was investigated with deformation/load provided using a bending rig. It was shown that the HEXRD method is capable of strain depth profiling to 2.5 mm. The method was validated using an aluminum sample where both the HEXRD method and the traditional X-ray diffraction method gave data compared with that obtained using destructive etching layer removal, performed by a commercial provider. The results demonstrate comparable accuracy up to 0.8 mm depth. Nevertheless, higher attenuation capabilities in heavier metals limit the applications in other materials. Simulations predict that HEXRD works for steel and nickel in material up to 200 µm, but experiment results indicate that the HEXRD strain profile is not practical for steel and nickel material, and the measured diffraction signals are undetectable when compared to the noise.

  17. Design of a New Collimation System to Prevent Interference between X-ray Machines and Radiation Portal Monitors

    International Nuclear Information System (INIS)

    Guzzardo, Tyler; Livesay, Jake

    2012-01-01

    Researchers at Oak Ridge National Laboratory (ORNL) developed a new collimation system that allows radiation portal monitors (RPMs) installed near x-ray machines to operate with a negligible false-positive alarm rate. RPMs are usually installed as far as possible from x-ray machines because false alarms are triggered by escaping x-rays; however, constraints at the installation site sometimes make it necessary that RPMs be installed near x-ray machines. Such RPMs are often plagued by high alarm rates resulting from the simultaneous operation of the RPMs and x-ray machines. Limitations on pedestrian flow, x-ray machine orientation, and RPM location often preclude a simple solution for lowering the alarm rate. Adding additional collimation to the x-ray machines to stop the x-rays at the source can reduce the alarm rate without interfering with site operations or adversely affecting the minimum detectable quantity of material (MDQ). A collimation design has been verified by measurements conducted at a RPM installation site and is applicable to all new and existing RPM installations near x-ray machines.

  18. Developments of compact pulsed-power system toward X-ray sources

    Directory of Open Access Journals (Sweden)

    Miyamoto Takuya

    2013-11-01

    Full Text Available In order to generate X-rays from X-pinch, the peak current and current-rising time required are estimated to be 100 kA and 100 ns, respectively. To obtain these parameters, we developed a pulsed-power system, which consists of a parallelized pulse-forming network (PFN. The 20 PFN modules of the system were driven at a charging voltage of 20 kV by a thin copper wire of load resistance. The results showed that the current and current-rising time are 18 kA and 107 ns, respectively. The wire/plasma temperature is 6.9 eV. The pulsed-power system is expected to generate X-rays from X-pinch by the proposed system. This can be achieved by raising the voltage and increasing the number of PFN modules.

  19. LabVIEW-based X-ray detection system for laser compton scattering experiment

    International Nuclear Information System (INIS)

    Luo Wen; Xu Wang; Pan Qiangyan

    2010-01-01

    A LabVIEW-based X-ray detection system has been developed for laser-Compton scattering (LCS) experiment at the 100 MeV Linac of the Shanghai Institute of Applied Physics (SINAP). It mainly consists of a Si (Li) detector, readout electronics and a LabVIEW-based Data Acquisition (DAQ), and possesses the functions of signal spectrum displaying, acquisition control and simple online data analysis and so on. The performance test shows that energy and time resolutions of the system are 184 eV at 5.9 keV and ≤ 1% respectively and system instability is found to be 0.3‰ within a week. As a result, this X-ray detection system has low-cost and high-performance features and can meet the requirements of LCS experiment. (authors)

  20. A microprogrammable high-speed data collection system for position sensitive X-ray detectors

    International Nuclear Information System (INIS)

    Hashizume, H.

    1984-01-01

    A high-speed data acquisition system has been designed which collects digital data from one- and two-dimensional position sensitive X-ray detectors at a maximum average data rate of 1 MHz. The system consists of two separate fast buffer memories, a 64 K word by 20-bit main storage, two timers, a display controller, a computer interface and a keyboard, controlled by a specially designed microprogrammable microprocessor. Data collection is performed by executing a microprogram stored in the control storage; data coming from a detector are first accumulated in a small but fast buffer memory by hardware and transferred to the main storage under control of the microprogram. This design not only permits time-resolved data collections but also provides maximum speed, flexibility and cost-effectiveness simultaneously. The system also accepts data from integrated detectors such as TV cameras. The system has been designed for use in experiments at conventional and synchrotron X-ray sources. (orig.)

  1. Introducing a standard method for experimental determination of the solvent response in laser pump, x-ray probe time-resolved wide-angle x-ray scattering experiments on systems in solution

    DEFF Research Database (Denmark)

    Kjær, Kasper Skov; Brandt van Driel, Tim; Kehres, Jan

    2013-01-01

    In time-resolved laser pump, X-ray probe wide-angle X-ray scattering experiments on systems in solution the structural response of the system is accompanied by a solvent response. The solvent response is caused by reorganization of the bulk solvent following the laser pump event, and in order...... response-the solvent term-experimentally when applying laser pump, X-ray probe time-resolved wide-angle X-ray scattering. The solvent term describes difference scattering arising from the structural response of the solvent to changes in the hydrodynamic parameters: pressure, temperature and density. We...... is demonstrated to exhibit first order behaviour with respect to the amount of energy deposited in the solution. We introduce a standardized method for recording solvent responses in laser pump, X-ray probe time-resolved X-ray wide-angle scattering experiments by using dye mediated solvent heating. Furthermore...

  2. X-ray apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Stagg, L.; Lambert, T.W.; Griswa, P.J.

    1976-01-01

    A patient support system for X-ray equipment in arteriographic studies of the heart is described in detail. The support system has been designed to overcome many of the practical problems encountered in using previous types of arteriographic X-ray equipment. The support system is capable of horizontal movement and, by a series of shafts attached to the main support system, the X-ray source and image intensifier or detector may be rotated through the same angle. The system is highly flexible and details are given of several possible operational modes. (U.K.)

  3. Chandra X-ray Center Science Data Systems Regression Testing of CIAO

    Science.gov (United States)

    Lee, N. P.; Karovska, M.; Galle, E. C.; Bonaventura, N. R.

    2011-07-01

    The Chandra Interactive Analysis of Observations (CIAO) is a software system developed for the analysis of Chandra X-ray Observatory observations. An important component of a successful CIAO release is the repeated testing of the tools across various platforms to ensure consistent and scientifically valid results. We describe the procedures of the scientific regression testing of CIAO and the enhancements made to the testing system to increase the efficiency of run time and result validation.

  4. Data acquisition and processing system of energy dispersive X-ray spectrometer with microprocessor

    International Nuclear Information System (INIS)

    Horkay, G.; Kis-Varga, M.; Lakatos, T.; Molnar, J.; Zsurzs, M.

    1984-01-01

    For quantitative analysis of chemical elements by the method of X-ray spectroscopy a multichannel analyzer on the base of minicomputer with the INTEL 8080 A microprocessor is developed. The data acquisition and data processing systems which comprise a central processor, memory unit, ADC and display are described. Major system subprograms are enumerated. An example of Pb concentration determinating in a bronze specimen is given

  5. Time response characteristics of X-ray detector system on Silex-Ⅰ laser facility

    International Nuclear Information System (INIS)

    Yi Rongqing; He Xiao'an; Li Hang; Du Huabing; Zhang Haiying; Cao Zhurong

    2013-01-01

    On the Silex-Ⅰ laser facility, the time response characteristics of XRD detector were studied. A laser with a pulse of 32 fs and a wavelength of 800 nm was used to irradiate a plane Au target. X-ray calibrated method of time of exposure X-ray framing camera and time resolution of X-ray streak camera was explored. The time response characteristics of XRD detector and time process of X-ray emission were obtained from experiment. We obtained X-ray calibration method of time of exposure X-ray framing camera and time resolution of X-ray streak camera. (authors)

  6. High resolution monochromatic X-ray imaging system based on spherically bent crystals

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Lehecka, T.; Obenschain, S.; Bodner, S.; Pawley, C.; Gerber, K.; Sethian, J.; Brown, C.M.; Seely, J.; Feldman, U.; Holland, G.

    1997-01-01

    We have developed a new X-ray imaging system based on spherically curved crystals. It is designed and used for diagnostics of targets ablatively accelerated by the Nike KrF laser [1,2]. The imaging system is used for plasma diagnostics of the main target and for characterization of potential backlighters. A spherically curved quartz crystal (2d=6.687 Angstrom, R=200mm) is used to produce monochromatic backlit images with the He-like Si resonance line (1865 eV) as the source of radiation. The spatial resolution of the X-ray optical system is 3 endash 4 μm. Time resolved backlit monochromatic images of CH planar targets driven by the Nike facility have been obtained with 6 endash 7 μm spatial resolution. copyright 1997 American Institute of Physics

  7. High resolution monochromatic X-ray imaging system based on spherically bent crystals

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Lehecka, T.; Obenschain, S.; Bodner, S.; Pawley, C.; Gerber, K.; Sethian, J.; Brown, C. M.; Seely, J.; Feldman, U.; Holland, G.

    1997-01-01

    We have developed a new X-ray imaging system based on spherically curved crystals. It is designed and used for diagnostics of targets ablatively accelerated by the Nike KrF laser. The imaging system is used for plasma diagnostics of the main target and for characterization of potential backlighters. A spherically curved quartz crystal (2d=6.687 A, R=200 mm) is used to produce monochromatic backlit images with the He-like Si resonance line (1865 eV) as the source of radiation. The spatial resolution of the X-ray optical system is 3-4 μm. Time resolved backlit monochromatic images of CH planar targets driven by the Nike facility have been obtained with 6-7 μm spatial resolution

  8. A system for time-resolved x-ray diffraction and its application to muscle contraction

    International Nuclear Information System (INIS)

    Amemiya, Yoshiyuki; Hashizume, Hiroo.

    1979-01-01

    A data-collection system has been built which permits time-resolved studies of X-ray diffraction diagrams obtained from contracting muscle on millisecond time scale. The system consists of a linear delay-line position sensitive proportional counter (PSPC), a special data transfer unit and an on-line computer. The PSPC used with a mirror-monochromator camera can detect equatorial reflections from stimulated muscle in a total exposure time of a few seconds. Time-resolved data-collection is achieved by stimulating muscle at a regular time interval, dividing a complete cycle of muscle contraction into many successive time slices and accumulating in computer memory X-ray data for each time slice from many repeated cycles of stimulation. The performances of the system have been demonstrated by recording equatorial reflections from frog skeletal muscle during isometric and isotonic twitch with a time resolution of 25 ms. (author)

  9. MIT modular x-ray source systems for the study of plasma diagnostics

    Science.gov (United States)

    Coleman, J. W.; Wenzel, K. W.; Petrasso, R. D.; Lo, D. H.; Li, C. K.; Lierzer, J. R.; Wei, T.

    1992-10-01

    Two new x-ray source systems are now on line at our facility. Each provides an e-beam to 25 kV. Targets are interchangeable between machines, and four x-ray detectors may be used simultaneously with a target. The gridded e-gun of the RACEHORSE system gives a 0.5-1.0-cm pulsable spot on target. The nongridded e-gun of the SCORPION system provides a 0.3-mm or smaller dc microspot on target. RACEHORSE is being used to study and characterize type-II diamond photoconductors for use in diagnosing plasmas, while SCORPION is being used to develop a slitless spectrograph using photographic film. Source design details and some RACEHORSE results are presented.

  10. Discussion of ALTERNATIVE systems for industrial radiography using X-ray films

    International Nuclear Information System (INIS)

    Vaessen B.; Perdieus, P.; Proegler, H.

    1995-01-01

    Industrial radiography using X-ray films is an established method of NDE. In the last few years, ''novel developments'' have been put on the market as ''alternatives'' to conventional radiography, as e.g. fluorescent screen/film systems, cost-saving films, wide-latitude films, and storage phosphor films. AGFA as a market leader in the sector of X-ray films for industrial radiography has been testing these alternatives, taking into account image quality, sensitivity, handling in terms of portability, reliability, and the essential functions for NDE: (1) Detection of X-radiation; (2) conversion to optical image; (3) evaluation and validation; (4) documentation and archivation. The advantages and drawbacks, the information transfer capabilities, and the performance from the applications point of view are discussed primarily for fluorescent screen/film systems and storage phophor systems. (orig./MM) [de

  11. State of development and development trends of X-ray image intensifier television systems

    International Nuclear Information System (INIS)

    Pfeiler, M.; Haendle, J.

    1975-01-01

    Following a survey on the development of X-ray image intensifier television systems up to now, their further development is critically discussed with regard to the better image quality to be expected. The introduction of the high-resolving X-ray image intensifier already meant an improvement in image quality even though the television system remained the same. In the image intensifier television system, the distinguishability of small details suffers from noise effects. Therefore, a better image quality is especially advantageous in those ranges of application which allow a higher picture dose. 'Electronic' radiography, intermittent screening, co-storage of the spotfilm radiographs, videometry, video area kymography, and cardiac stroboscopy are examples some of which have already been tested in clinical practice. (orig./AK) [de

  12. Automation of an X-ray diffractometer using a manually preset control system

    International Nuclear Information System (INIS)

    Berry, T.; Prentice, P.C.

    1978-11-01

    The measurements of lattice parameters of beta silicon carbide nuclear reactor temperature monitors at Dounreay were formerly carried out using an X-ray diffractometer connected to a simple step scan control system with an analysis time of 8 hours per specimen. A system is described whereby the step scan throughout of the X-ray diffractometer is increased by using an automatic sample charger and additional control electronics, allowing round-the-clock analysis. The original system which used Harwell 2000 series electronic units has been expanded to include an AERE designed goniometer control unit, a Philips sample changer with control unit, and a Honeywell chart recorder. The integrated circuit logic used, interconnections of modules, and operating instructions are given in appendices. (UK)

  13. Analyzer-based phase-contrast imaging system using a micro focus x-ray source

    International Nuclear Information System (INIS)

    Zhou, Wei; Majidi, Keivan; Brankov, Jovan G.

    2014-01-01

    Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten Kα 1 line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample

  14. Analyzer-based phase-contrast imaging system using a micro focus x-ray source

    Science.gov (United States)

    Zhou, Wei; Majidi, Keivan; Brankov, Jovan G.

    2014-08-01

    Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten Kα1 line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample.

  15. Analyzer-based phase-contrast imaging system using a micro focus x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Wei [BME Department, Illinois Institute of Technology, Chicago, Illinois 60616 (United States); Majidi, Keivan; Brankov, Jovan G., E-mail: brankov@iit.edu [ECE Department, Illinois Institute of Technology, Chicago, Illinois 60616 (United States)

    2014-08-15

    Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten Kα{sub 1} line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample.

  16. Optical, Near-IR, and X-Ray Observations of SN 2015J and Its Host Galaxy

    Science.gov (United States)

    Nucita, A. A.; De Paolis, F.; Saxton, R.; Testa, V.; Strafella, F.; Read, A.; Licchelli, D.; Ingrosso, G.; Convenga, F.; Boutsia, K.

    2017-12-01

    SN 2015J was discovered on 2015 April 27th and is classified as an SN IIn. At first, it appeared to be an orphan SN candidate, I.e., without any clear identification of its host galaxy. Here, we present an analysis of the observations carried out by the VLT 8 m class telescope with the FORS2 camera in the R band and the Magellan telescope (6.5 m) equipped with the IMACS Short-Camera (V and I filters) and the FourStar camera (Ks filter). We show that SN 2015J resides in what appears to be a very compact galaxy, establishing a relation between the SN event and its natural host. We also present and discuss archival and new X-ray data centered on SN 2015J. At the time of the supernova explosion, Swift/XRT observations were made and a weak X-ray source was detected at the location of SN 2015J. Almost one year later, the same source was unambiguously identified during serendipitous observations by Swift/XRT and XMM-Newton, clearly showing an enhancement of the 0.3-10 keV band flux by a factor ≃ 30 with respect to the initial state. Swift/XRT observations show that the source is still active in the X-rays at a level of ≃ 0.05 counts s-1. The unabsorbed X-ray luminosity derived from the XMM-Newton slew and SWIFT observations, {L}x≃ 5× {10}41 erg s-1, places SN 2015J among the brightest young supernovae in X-rays. Based on observations obtained with XMM-Newton, an ESA science mission with instruments and contributions directly funded by ESA Member States and NASA, with ESO Telescopes at the La Silla-Paranal Observatory under program ID 298.D-5016(A), and with the 6.5 m Magellan Telescopes located at Las Campanas Observatory, Chile. We also acknowledge the use of public data from the Swift data archive.

  17. A high rate, low noise, x-ray silicon strip detector system

    International Nuclear Information System (INIS)

    Ludewigt, B.; Jaklevic, J.; Kipnis, I.; Rossington, C.; Spieler, H.

    1993-11-01

    An x-ray detector system, based on a silicon strip detector wire-bonded to a low noise charge-senstive amplifier integrated circuit, has been developed for synchrotron radiation experiments which require very high count rates and good energy resolution. Noise measurements and x-ray spectra were taken using a 6 mm long, 55 μm pitch strip detector in conjunction with a prototype 16-channel charge-sensitive preamplifier, both fabricated using standard 1.2 μm CMOS technology. The detector system currently achieves an energy resolution of 350 eV FWHM at 5.9 key, 2 μs peaking time, when cooled to -5 degree C

  18. High-resolution monochromatic x-ray imaging system based on spherically bent crystals

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Lehecka, T.; Obenschain, S.; Bodner, S.; Pawley, C.; Gerber, K.; Sethian, J.; Brown, C.M.; Seely, J.; Feldman, U.; Holland, G.

    1998-01-01

    We have developed an improved x-ray imaging system based on spherically curve crystals. It is designed and used for diagnostics of targets ablatively accelerated by the Nike KrF laser. A spherically curved quartz crystal (2d=6.687 Angstrom, R=200 mm) has been used to produce monochromatic backlit images with the He-like Si resonance line (1865 eV) as the source of radiation. The spatial resolution of the x-ray optical system is 1.7 μm in selected places and 2 - 3 μm over a larger area. Time-resolved backlit monochromatic images of polystyrene planar targets driven by the Nike facility have been obtained with a spatial resolution of 2.5 μm in selected places and 5 μm over the focal spot of the Nike laser. copyright 1998 Optical Society of America

  19. Building a graphite calorimetry system for the dosimetry of therapeutic x-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Jung; Kim, Byoung Chul; Kim, Joong Hyun; Chung, Jae Pil; Kim, Hyun Moon; Yi, Chul Young [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2017-06-15

    A graphite calorimetry system was built and tested under irradiation. The noise level of the temperature measurement system was approximately 0.08 mK (peak to peak). The temperature of the core part rose by approximately 8.6 mK at 800 MU (monitor unit) for 6-MV X-ray beams, and it increased as X-ray energy increased. The temperature rise showed less spread when it was normalized to the accumulated charge, as measured by an external monitoring chamber. The radiation energy absorbed by the core part was determined to have values of 0.798 J/μC, 0.389 J/μC, and 0.352 J/μC at 6 MV, 10 MV, and 18 MV, respectively. These values were so consistent among repeated runs that their coefficient of variance was less than 0.15%.

  20. An application specific integrated circuit and data acquisition system for digital X-ray imaging

    International Nuclear Information System (INIS)

    Beuville, E.; Cederstroem, B.; Danielsson, M.; Luo, L.; Nygren, D.; Oltman, E.; Vestlund, J.

    1998-01-01

    We have developed an application specific integrated circuit (ASIC) and data acquisition system for digital X-ray imaging. The chip consists of 16 parallel channels, each containing preamplifier, shaper, comparator and a 16 bit counter. We have demonstrated noiseless single-photon counting over a threshold of 7.2 keV using Silicon detectors and are presently capable of maximum counting rates of 2 MHz per channel. The ASIC is controlled by a personal computer through a commercial PCI card, which is also used for data acquisition. The content of the 16 bit counters are loaded into a shift register and transferred to the PC at any time at a rate of 20 MHz. The system is non-complicated, low cost and high performance and is optimised for digital X-ray imaging applications. (orig.)

  1. An application specific integrated circuit and data acquisition system for digital X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Beuville, E.; Cederstroem, B.; Danielsson, M.; Luo, L.; Nygren, D.; Oltman, E.; Vestlund, J. [Lawrence Berkeley National Lab., CA (United States)

    1998-04-01

    We have developed an application specific integrated circuit (ASIC) and data acquisition system for digital X-ray imaging. The chip consists of 16 parallel channels, each containing preamplifier, shaper, comparator and a 16 bit counter. We have demonstrated noiseless single-photon counting over a threshold of 7.2 keV using Silicon detectors and are presently capable of maximum counting rates of 2 MHz per channel. The ASIC is controlled by a personal computer through a commercial PCI card, which is also used for data acquisition. The content of the 16 bit counters are loaded into a shift register and transferred to the PC at any time at a rate of 20 MHz. The system is non-complicated, low cost and high performance and is optimised for digital X-ray imaging applications. (orig.). 11 refs.

  2. Peak potential meter applied to X-ray tubes in mammal radiography systems

    International Nuclear Information System (INIS)

    Schiabel, Homero; Frere, Annie F.; Andreeta, Jose P.

    1989-01-01

    It is of a great importance to identify accurately the real peak potential (or simply, KVp) applied to a X-ray tube purposed to medical diagnosis, since it defines the beam energetic quality in terms of photons penetration power. Mainly in mammographic systems. it is of fundamental relevance the KVp accurate measurement because the soft tissues involved in this kind of examination provides different absorption - and, hence, clear contrast on mammographic film - just in a very restrict energetic range. Thus a device to measure KVp with adequate accuracy in mammographic units, using the basic principles of scintillation detection, was developed. This system is therefore composed of a NaI(Tl) crystal which is a X-ray sensor - replacing radiographic films which usually are a source of errors in these measurements - , a photo multiplier tube and changed into amplified electric pulses. Finally the electronic circuit, after adequate pulses treatment, shows instantaneously the actual KVp value in the test on displays. (author)

  3. Evaluation of a computer aided X-ray fluorographic system: Part II - image processing

    International Nuclear Information System (INIS)

    Burch, S.F.; Cocking, S.J.

    1981-12-01

    The TV imagery from a computer aided X-ray fluorographic system has been digitally processed with an I 2 S model 70E image processor, controlled by a PDP 11/60 minicomputer. The image processor allowed valuable processing for detection of defects in cast components to be carried out at television frame rates. Summation of TV frames was used to reduce noise, and hence improve the thickness sensitivity of the system. A displaced differencing technique and interactive contrast enhancement were then used to improve the reliability of inspection by removing spurious blemishes and interference lines, while simultaneously enhancing the visibility of real defects. The times required for these operations are given, and the benefits provided for X-ray fluorography are illustrated by the results from inspection of aero engine castings. (author)

  4. New x-ray optical system for fluorescence beamline at Hasylab

    International Nuclear Information System (INIS)

    Falkenberg, G.; Tschentscher, T.

    2000-01-01

    Beamline L at HASYLAB/DESY is actually dedicated to micro x-ray fluorescence (μ-XRF) experiments using the white beam from a bending magnet of the storage ring DORIS III. To extend the applicability of beamline L to other x-ray fluorescence techniques, such as synchrotron radiation total reflection x-ray fluorescence (SR-TXRF) and micro x-ray absorption near edge structures in fluorescence mode (μ-XANES), new x-ray optics have been designed and are under installation at the moment. The suitability of beamline L for SR-TXRF experiments has been shown previously in a number of studies using temporary setups for beam monochromatization and collimation. The new optical system comprises a slit system, a pair of x-ray mirrors for focussing, collimation and high energy cut-off (12 keV and 30 keV), a double multilayer monochromator for broad bandpass applications (TXRF) and a double perfect-crystal monochromator for spectroscopy (XANES, speciation). The multilayer monochromator will utilize a pair of NiC with a spacing of 4.0 nm for the energy range 2-10 keV and a second pair of WB 4 C with a spacing of 3.0 nm for the range 4-30 keV. To extend the energy range for broad bandpass applications to higher photon energies SiGe gradient crystals are foreseen (ΔE/E ∼ 10 -3 ). For the perfect-crystal monochromator we have chosen a pair of Ge 111 crystals for the energy range 2-10 keV and Si 111 crystals for 7-90 keV. To enable the use of low photon energies down to 2 keV the monochromator vessel is sealed to the ring vacuum by a 25 μm thick carbon window. The mirrors and monochromators deflect the beam vertically and can be moved out of the beam independently. Fixed exit geometry permits the illumination of the same sample spot with different wavelength and energy bands. All optical elements accept the full vertical beam opening in order to enable both vertical and horizontal geometries for sample and detector. (author)

  5. X-ray studies on a two-dimensional diffusion limited system for cell growth

    International Nuclear Information System (INIS)

    Hlatky, L.R.; Alpen, E.L.

    1985-01-01

    X-ray studies were performed on cells grown in a new type of in vitro multicellular system, the ''sandwich'' system. This system is a two-dimensional array of cells, sandwiched between transparent slides which are impermeable to oxygen. The cell system is subject to self-created diffusion gradients of nutrients, metabolic products and, most importantly, oxygen. Sandwiches are analogous to living cross sections of multicellular spheroids or of poorly vascularized tumors. They contain a necrotic center, which the authors show to be due to diffusion limitations, an intermediate region which has a large fraction of quiescent cells and a cycling outer rim. One advantage sandwiches have over three-dimensional tumor models (sheproids) is that can control the amount of cell to cell contact and thereby separate effects due to oxygen or other gradients from effects due to contact. The authors present x-ray survival curves for sandwiches of various cell densities and compare them to x-ray survival curves done for spheroids and monolayers of the same cell line

  6. A compact x-ray system for two-phase flow measurement

    Science.gov (United States)

    Song, Kyle; Liu, Yang

    2018-02-01

    In this paper, a compact x-ray densitometry system consisting of a 50 kV, 1 mA x-ray tube and several linear detector arrays is developed for two-phase flow measurement. The system is capable of measuring void fraction and velocity distributions with a spatial resolution of 0.4 mm per pixel and a frequency of 1000 Hz. A novel measurement model has been established for the system which takes account of the energy spectrum of x-ray photons and the beam hardening effect. An improved measurement accuracy has been achieved with this model compared with the conventional log model that has been widely used in the literature. Using this system, void fraction and velocity distributions are measured for a bubbly and a slug flow in a 25.4 mm I.D. air-water two-phase flow test loop. The measured superficial gas velocities show an error within  ±4% when compared with the gas flowmeter for both conditions.

  7. Development of the measurement system with interferometers for ultraprecise X-ray mirror

    CERN Document Server

    Yamauchi, K; Mimura, H

    2003-01-01

    A figure measurement system with a stitching method has been developed for evaluation and fabrication of the ultraprecise hard X-ray mirror optics. This system was constructed by two interferometers. One is the Michelson-type microscopic interferometer which is improved to keep the focus distance within 0.1 mu m. Another is the Fizeau's interferometer employed to compensate stitching error in the long spatial wavelength range. To estimate the absolute accuracy in this figure measurement system, the reflection X-ray intensity distributions of flat and aspherical mirrors, which are fabricated by us, were predicted by wave-optical simulation based on measured profile an compared with actually observed distributions. As the result, they are in good agreements. These agreements prove that the developed system has sub-nanometer absolute accuracy in all the spatial wavelength range longer than 0.5mm, because sub-nanometer figure error in those spatial wavelength ranges are known to affect reflection X-ray intensity ...

  8. Role of Bi promotion and solvent in platinum-catalyzed alcohol oxidation probed by in situ X-ray absorption and ATR-IR spectroscopy

    DEFF Research Database (Denmark)

    Mondelli, C.; Grunwaldt, Jan-Dierk; Ferri, D.

    2010-01-01

    the catalysts under working conditions using in situ X-ray absorption spectroscopy (XAS) and attenuated total reflection infrared spectroscopy (ATR-IR), aiming at uncovering the roles of the metal promoter and the reaction medium. XAS confirms that Bi is oxidized more easily than Pt, maintaining the catalytic...... surfaces than on step or kink sites. Side products, CO and benzoate species, appearing during the reaction reveal that the geometric suppression of undesired reactions does not occur to the same extent on Pt-based catalysts as on Pd, suggesting that decarbonylation of the produced aldehyde on Pt may occur...

  9. Optimization of a multilayer Laue lens system for a hard x-ray nanoprobe

    International Nuclear Information System (INIS)

    Jiang, Hui; Wang, Hua; Mao, Chengwen; Li, Aiguo; He, Yan; Dong, Zhaohui; Zheng, Yi

    2014-01-01

    Detailed designs of a multilayer Laue lens system for a hard x-ray nanoprobe, including flat and wedged types, are presented, to realize nanoscale point focus and high diffraction efficiency simultaneously. The difficulty of movement and alignment for lens, aperture and sample are considered in the optimization process. Considering the practical requirements of future experiments, the features of the beamline and the structural imperfections, the working energy range, the beam vibration and structural errors are estimated and discussed. (paper)

  10. A quasi-realtime x-ray microtomography system at the Advanced Photon Source

    International Nuclear Information System (INIS)

    DeCarlo, F.; Foster, I.; Insley, J.; Kesselman, C.; Lane, P.; Mancini, D.; McNulty, I.; Su, M.; Tieman, B.; Wang, Y.; Laszewski, G. von

    1999-01-01

    The combination of high-brilliance x-ray sources, fast detector systems, wide-bandwidth networks, and parallel computers can substantially reduce the time required to acquire, reconstruct, and visualize high-resolution three-dimensional tomographic datasets. A quasi-realtime computed x-ray microtomography system has been implemented at the 2-BM beamline at the Advanced Photon Source at Argonne National Laboratory. With this system, a complete tomographic data set can be collected in about 15 minutes. Immediately after each projection is obtained, it is rapidly transferred to the Mathematics and Computing Sciences Division where preprocessing and reconstruction calculations are performed concurrently with the data acquisition by a SGI parallel computer. The reconstruction results, once completed, are transferred to a visualization computer that performs the volume rendering calculations. Rendered images of the reconstructed data are available for viewing back at the beamline experiment station minutes after the data acquisition was complete. The fully pipelined data acquisition and reconstruction system also gives us the option to acquire the tomographic data set in several cycles, initially with coarse then with fine angular steps. At present the projections are acquired with a straight-ray projection imaging scheme using 5-20 keV hard x rays in either phase or amplitude contrast mode at a 1-10 pm resolution. In the future, we expect to increase the resolution of the projections to below 100 nm by using a focused x-ray beam at the 2-ID-B beamline and to reduce the combined acquisition and computation time to the 1 min scale with improvements in the detectors, network links, software pipeline, and computation algorithms

  11. Optimization of an X-ray diffraction imaging system for medical and security applications

    International Nuclear Information System (INIS)

    Marticke, Fanny

    2016-01-01

    X-ray diffraction imaging is a powerful noninvasive technique to identify or characterize different materials. Compared to traditional techniques using X-ray transmission, it allows to extract more material characteristic information, such as the Bragg peak positions for crystalline materials as well as the molecular form factor for amorphous materials. The potential of this technique has been recognized by many researchers and numerous applications such as luggage inspection, nondestructive testing, drug detection and biological tissue characterization have been proposed. The method of energy dispersive X-ray diffraction (EDXRD) is particularly suited for this type of applications as it allows the use of a conventional X-ray tube, the acquisition of the whole spectrum at the same time and parallelized architectures to inspect an entire object in a reasonable time. The purpose of the present work is to optimize the whole material characterization chain. Optimization comprises two aspects: optimization of the acquisition system and of data processing. The last one concerns especially the correction of diffraction pattern degraded by acquisition process. Reconstruction methods are proposed and validated on simulated and experimental spectra. System optimization is realized using figures of merit such as detective quantum efficiency (DQE), contrast to noise ratio (CNR) and receiver operating characteristic (ROC) curves.The first chosen application is XRD based breast imaging which aims to distinguish cancerous tissues from healthy tissues. Two non-multiplexed collimation configurations combining EDXRD and ADXRD are proposed after optimization procedure. A simulation study of the whole system and a breast phantom was realized to determine the required dose to detect a 4 mm carcinoma nodule. The second application concerns detection of illicit materials during security check. The possible benefit of a multiplexed collimation system was examined. (author) [fr

  12. The use of a CCD imaging system for X-ray film intensity measurement

    International Nuclear Information System (INIS)

    Grigg, M.W.; Barnea, Z.

    1994-01-01

    The use of a simple CCD-based imaging system for digitizing and x-ray film image is demonstrated. A method of extending the region of linear response of the film based upon an analytic representation of the observed response to a series of increasing exposures is described. The validity of the procedure is illustrated through an example of the absolute intensity measurement of a reflection of cadmium sulphide. 3 refs., 7 figs

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... changes seen in metabolic conditions. assist in the detection and diagnosis of bone cancer . locate foreign objects ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ...

  16. Dedicated Stereophotogrammetric X-Ray System For Craniofacial Research And Treatment Planning

    Science.gov (United States)

    Baumrind, Sheldon; Moffitt, Francis; Curry, Sean; Isaacson, Robert J.

    1983-07-01

    We have constructed and brought into use what we believe to be the first dedicated coplanar craniofacial stereometric x-ray system for clinical use. Paired Machlett Dynamax 50/58 x-ray tubes with 0.3 mm focal spots are employed. Displacement between emitters is 16 inches. The focus film distance for both emitters is 66.5 inches. The mid-sagittal plane to focus distance is 60 inches. One film of each stereo pair conforms with the standards of the Second Roentgenocephalometric Workshop and can be used to make all standard two-dimensional orthodontic and cephalometric measurements. When supplemented by data from the conjugate film, a three-dimensional coordinate map can be generated as a machine operation. Specialized complementary software has been developed to increase the reliability of landmark location both in two and in three dimensions.

  17. Mechanical system design in the engineering design of digital x-ray

    International Nuclear Information System (INIS)

    Muhammad Awwaluddin; I Putu Susila; Edy Purwanta; Abdul Jalil; Ahmad H

    2014-01-01

    Has been designed a mechanical system design to hold and moving the x-ray tube, detector films, and a place the holder control box. The design was conducted on the frame foundation, frame columns and frame arms in order to operate the device as well SS304 hollow measuring 40 x 60 x mm with thickness of 2 mm long 4.1 m, size 100 x 100 mm and 2 mm thick along the 2 m, and the size of 40 x 80 mm thickness 2 mm long 1.8 m is needed to reactive the design the linear guide way models HGW20HB 3 m. With the proposed design, the operation of the digital x-rays can be completed as well. (author)

  18. An X-ray photoelectron spectroscopic study of the B-N-Ti system

    Energy Technology Data Exchange (ETDEWEB)

    Seal, S. [Lawrence Berkeley National Lab., CA (United States); Barr, T.L. [Univ. of Wisconsin, Milwaukee, WI (United States); Sobczak, N. [Foundry Research Inst., Cracow (Poland); Benko, E. [Inst. of Metal Cutting, Cracow (Poland); Morgiel, J. [Polish Academy of Sciences, Cracow (Poland). Inst. of Metallurgy and Materials Science

    1997-03-01

    Composite nitrides (such as BN, TiN) are widely used in various industrial applications because of their extreme wear and corrosion resistance, thermal and electrical properties. In order to obtain composite materials with these optimal properties, it is important to elucidate whether any chemical reactions occur at nitride/metal interfaces, e.g., those involving BN-Ti/TiN. Materials of interest include the deposition by PVD of Ti and TiN on BN substrates. Some of these systems were then subjected to varying degrees of physical and thermal alteration. Detailed X-ray photoelectron spectroscopy (XPS) has therefore been rendered of these interfaces using cross-sectional display and sputter etching. Resulting structural and morphological features have been investigated with transmission electron microscopy (TEM) and X-ray diffraction (XRD). Diffusion of the nitridation, oxynitride formation and interfacial growth are of general interest.

  19. Where is the X-ray emission coming from in RT Cru Symbiotic System?

    Science.gov (United States)

    Karovska, Margarita

    2014-11-01

    RT Cru is a member of a new sub-class of symbiotic interacting binaries with copious hard X-ray emission. It consists of a high-mass WD (>1.3 Ms) accreting from the wind of an M giant, and it is an important system to study in order to constrain precursor conditions for asymmetric PN and SN Ia. The Chandra HRC-I observation (Dec 2012), and an overlapping Swift observation, detected intermittent soft X-ray flaring, and we find evidence for a significant soft component in the spectrum. The flaring could be a consequence of clumped absorption columns moving in and out of the line of sight, or the variations could be due to changes at the accretion boundary layer. Further observations are needed to determine the origin of the soft emission and its relation to the hard emission.

  20. Radiography imaging of cultural heritage obtained with a modified portable X-Ray Fluorescence System

    International Nuclear Information System (INIS)

    Mendoza Cuevas, Ariadna; Velazquez Maldonado, Luis Ramon

    2011-01-01

    The sufficiency of imaging quality of the radiographies obtained with a modified portable X-ray fluorescence spectrometer was evaluated for the study of cultural heritage. The proposed instrument use an X-ray tube with Pd anode (2 mm) that allows a maximum voltage and current of 50 kV and 1 mA respectively and a collimation system permit to irradiate a square shape region in the analyzed object by the projection of light beam with the same shape on its surface. The spatial resolution of the obtained radiographic image make possible to localize and well define pentimenti in painting, identify filling materials in a painting under restoration process, the radiogrametry of archaeological bone and the identification of a petrified sphere from an archaeological discovery. The radiographic analysis is proposed for study of physical anthropology in Cuba. (author)

  1. A Study on Mono-energetic Beam Source Using Characteristic X-ray for Substance Identification System

    International Nuclear Information System (INIS)

    Lee, Hwan Soo

    2009-02-01

    A new mono-energetic beam source was developed by using characteristic X-ray for improving performance of the substance identification system. Most of inspection systems use X-ray tubes for their source modules. However, the broad energy spectrum of X-ray tube causes an increase of uncertainty. In this study, it was found that mono-energetic beam sources can be generated by using X-ray tube and the designed target filter assembly. In order to investigate the monoenergetic beam source, the sensitivity study was conducted with a series of different X-ray tube potentials, radiator and filter materials using Monte Carlo simulation. The developed beam sources have a mono-energy peak at 69 keV, 78 keV and 99 keV, and they are named as characteristic X-ray beam BEAM69, BEAM78 and BEAM99, respectively. The characteristic X-ray beam intensity was over thirty three times more than that of hardening beam used previous work at Hanyang University. And BEAM69 and BEAM99 were applied to the substance identification system as a source. The relative error between results of characteristic X-ray beams and 69 keV and 99 keV photons was about 2% on the average for five unknown materials. In comparison with experiment results by using hardening beam, characteristic X-ray beam achieves better accuracy which is about 6.46 % on the average. Hence, it is expected that the developed characteristic X-ray beam source helps lower uncertainty of the inspection system, and the inspection time will be reduced considerably due to its high beam intensity

  2. Automatic sample changer system for a chain of X-Ray Spectrometry

    International Nuclear Information System (INIS)

    Kall, B.

    2004-01-01

    Nowadays, the science evolves and the used techniques become more pointed. At the same time, instruments are more powerful. This rule also applies in the domain of the nuclear science. The object of these works goes in this sense and touch the branch of the X-Ray spectrometry and that brings back himself to the conception and the realization of an automatic sample changer system for the chain of X-Ray Spectrometry. Baptized KEN-001 , it is an instrument of sample changer ordered from certain distance. Indeed, the sample carriers are placed of advance in compartments on its tray and by a control, KEN-001 put one by one those reflectors in the carries reflective for analysis. Once the analysis is finished, the system is in charge of taking and replacing the reflector in its compartment of origin. Of this way, one wins in time and therefore in number of analysis to do in an interval of time given. This instrument of precision contributes to the improvement of the analysis and the evolution of the technique of the X-Ray fluorescence [fr

  3. Material recognition with the Medipix photon counting colour X-ray system

    Energy Technology Data Exchange (ETDEWEB)

    Norlin, B. E-mail: borje.norlin@mh.se; Manuilskiy, A.; Nilsson, H.-E.; Froejdh, C

    2004-09-21

    An energy sensitive imaging system like Medipix1 has proved to be promising in distinguishing different materials in an X-ray image of an object. We propose a general method utilising X-ray energy information for material recognition. For objects where the thickness of the materials is unknown, a convenient material parameter to identify is K={alpha}{sub 1}/{alpha}{sub 2}, which is the ratio of the logarithms of the measured transmissions ln(t{sub 1})/ln(t{sub 2}). If a database of the parameter K for different materials and energies is created, this method can be used for material recognition independent of the thickness of the materials. Series of images of an object consisting of aluminium and silicon were taken with different energy thresholds. The X-ray absorption for silicon and aluminium is very similar for the range 40-60 keV and only differs for lower energies. The results show that it is possible to distinguish between aluminium and silicon on images achieved by Medipix1 using a standard dental source. By decreasing the spatial resolution a better contrast between the materials was achieved. The resolution of contrasts shown by the histograms was close to the limit of the system due to the statistical noise of the signal.

  4. Tissue Equivalent Phantom Design for Characterization of a Coherent Scatter X-ray Imaging System

    Science.gov (United States)

    Albanese, Kathryn Elizabeth

    Scatter in medical imaging is typically cast off as image-related noise that detracts from meaningful diagnosis. It is therefore typically rejected or removed from medical images. However, it has been found that every material, including cancerous tissue, has a unique X-ray coherent scatter signature that can be used to identify the material or tissue. Such scatter-based tissue-identification provides the advantage of locating and identifying particular materials over conventional anatomical imaging through X-ray radiography. A coded aperture X-ray coherent scatter spectral imaging system has been developed in our group to classify different tissue types based on their unique scatter signatures. Previous experiments using our prototype have demonstrated that the depth-resolved coherent scatter spectral imaging system (CACSSI) can discriminate healthy and cancerous tissue present in the path of a non-destructive x-ray beam. A key to the successful optimization of CACSSI as a clinical imaging method is to obtain anatomically accurate phantoms of the human body. This thesis describes the development and fabrication of 3D printed anatomical scatter phantoms of the breast and lung. The purpose of this work is to accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Tissue-equivalent anatomical phantoms were designed to assess the capability of the CACSSI system to classify different types of breast tissue (adipose, fibroglandular, malignant). These phantoms were 3D printed based on DICOM data obtained from CT scans of prone breasts. The phantoms were tested through comparison of measured scatter signatures with those of adipose and fibroglandular tissue from literature. Tumors in the phantom were modeled using a variety of biological tissue including actual surgically excised benign and malignant tissue specimens. Lung based phantoms have also been printed for future

  5. U arm type x-ray radiograph system for circulatory system

    International Nuclear Information System (INIS)

    Kiuchi, Shigeo; Kaga, Yuji; Sato, Masami; Komatsuda, Yasushi; Nishio, Kosaku.

    1979-01-01

    This report is concerned with the function and usefulness of U arm type X-ray radiograph system for circulatory system jointly developed by Yamagata University and Toshiba Medical Co., Ltd. The system was used 560 times in 2 years mostly for cinephotography. It has such features as follows: (1) The compound oblique position radiography mechanism of U arm is useful for the separative radiography around coronary artery. (2) The mechanism of U arm is very quick in photographing with fluoroscopy. (3) Very sharp II indirect biplane photographs without obscurity due to enlarging can be taken. (4) An operator can position objects readily by operating a sterilizing switch. (5) Both short time photographing of 1 m sec and high speed repeated photographing of 12 times/sec can be made with the photo timer. (6) The fog due to mutual scattering in RSC biplane photographing can be removed by II blanking method. (Kobatake, H.)

  6. X-ray filter for x-ray powder diffraction

    Science.gov (United States)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.; Dooryhee, Eric; Ghose, Sanjit

    2018-01-23

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and walls defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.

  7. Soft x-ray imaging system for measurement of noncircular tokamak plasmas

    International Nuclear Information System (INIS)

    Fonck, R.J.; Reusch, M.; Jaehnig, K.P.; Hulse, R.; Roney, P.

    1986-08-01

    A soft x-ray camera and image processing system has been constructed to provide measurements of the internal shape of high temperature tokamak plasmas. The camera consists of a metallic-foil-filtered pinhole aperture and a microchannel plate image intensifier/convertor which produces a visible image for detection by a CCD TV camera. A wide-angle tangential view of the toroidal plasma allows a single compact camera to view the entire plasma cross section. With Be filters 12 to 50 μm thick, the signal from the microchannel plate is produced mostly by nickel L-line emissions which orignate in the hot plasma core. The measured toroidal image is numerically inverted to produce a cross-sectional soft x-ray image of the plasma. Since the internal magnetic flux surfaces are usually isothermal and the nickel emissivity depends strongly on the local electron temperature, the x-ray emission contours reflect the shape of the magnetic surfaces in the plasma interior. Initial results from the PBX tokamak experiment show clear differences in internal plasma shapes for circular and bean-shaped discharges

  8. X-ray detector

    International Nuclear Information System (INIS)

    Whetten, N.R.; Houston, J.M.

    1977-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of x-ray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes. 8 figures

  9. Probing Large-scale Coherence between Spitzer IR and Chandra X-Ray Source-subtracted Cosmic Backgrounds

    Energy Technology Data Exchange (ETDEWEB)

    Cappelluti, N.; Urry, M. [Yale Center for Astronomy and Astrophysics, P.O. Box 208120, New Haven, CT 06520 (United States); Arendt, R. [University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, MD 21250 (United States); Kashlinsky, A. [Observational Cosmology Laboratory, NASA Goddard Space Flight Center, Code 665, Greenbelt, MD 20771 (United States); Li, Y.; Hasinger, G. [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); Helgason, K. [Department of Astronomy, Yale University, P.O. Box 208101, New Haven, CT 06520 (United States); Natarajan, P. [Max Planck Institute for Astrophysics, Karl-Schwarzschild-Str. 1, D-85748 Garching (Germany); Finoguenov, A. [Max-Planck-Institut für extraterrestrische Physik, Postfach 1312, D-85741, Garching bei München (Germany)

    2017-09-20

    We present new measurements of the large-scale clustering component of the cross-power spectra of the source-subtracted Spitzer -IRAC cosmic infrared background and Chandra -ACIS cosmic X-ray background surface brightness fluctuations Our investigation uses data from the Chandra Deep Field South, Hubble Deep Field North, Extended Groth Strip/AEGIS field, and UDS/SXDF surveys, comprising 1160 Spitzer hours and ∼12 Ms of Chandra data collected over a total area of 0.3 deg{sup 2}. We report the first (>5 σ ) detection of a cross-power signal on large angular scales >20″ between [0.5–2] keV and the 3.6 and 4.5 μ m bands, at ∼5 σ and 6.3 σ significance, respectively. The correlation with harder X-ray bands is marginally significant. Comparing the new observations with existing models for the contribution of the known unmasked source population at z < 7, we find an excess of about an order of magnitude at 5 σ confidence. We discuss possible interpretations for the origin of this excess in terms of the contribution from accreting early black holes (BHs), including both direct collapse BHs and primordial BHs, as well as from scattering in the interstellar medium and intra-halo light.

  10. First use of portable system coupling X-ray diffraction and X-ray fluorescence for in-situ analysis of prehistoric rock art.

    Science.gov (United States)

    Beck, L; Rousselière, H; Castaing, J; Duran, A; Lebon, M; Moignard, B; Plassard, F

    2014-11-01

    Study of prehistoric art is playing a major role in the knowledge of human evolution. Many scientific methods are involved in this investigation including chemical analysis of pigments present on artefacts or applied to cave walls. In the past decades, the characterization of coloured materials was carried on by taking small samples. This procedure had two main disadvantages: slight but existing damage of the paintings and limitation of the number of samples. Thanks to the advanced development of portable systems, in-situ analysis of pigment in cave can be now undertaken without fear for this fragile Cultural Heritage. For the first time, a portable system combining XRD and XRF was used in an underground and archaeological environment for prehistoric rock art studies. In-situ non-destructive analysis of black prehistoric drawings and determination of their composition and crystalline structure were successfully carried out. Original results on pigments used 13,000 years ago in the cave of Rouffignac (France) were obtained showing the use of two main manganese oxides: pyrolusite and romanechite. The capabilities of the portable XRD-XRF system have been demonstrated for the characterization of pigments as well as for the analysis of rock in a cave environment. This first in-situ experiment combining X-ray diffraction and X-ray fluorescence open up new horizons and can fundamentally change our approach of rock art studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. CIAO: A Modern Data Analysis System for X-Ray Astronomy

    Science.gov (United States)

    Fruscione, Antonella

    2017-08-01

    It is now eighteen years after launch and Chandra continues to produce spectacular results!A portion of the success is to be attributed to the data analysis software CIAO (Chandra Interactive Analysis of Observations) that the Chandra X-Ray Center (CXC) continues to improve and release year after year.CIAO is downloaded more than 1200 times a year and it is used by a wide variety of users around the world: from novice to experienced X-ray astronomers, high school, undergraduate and graduate students, archival users (many new to X-ray or Chandra data), users with extensive resources and others from smaller countries and institutions.The scientific goals and kinds of datasets and analysis cover a wide range: observations spanning from days to years, different instrument configurations and different kinds of targets, from pointlike stars and quasars, to fuzzy galaxies and clusters, to moving solar objects. These different needs and goals require a variety of specialized software and careful and detailed documentation which is what the CIAO software provides. In general, we strive to build a software system which is easy for beginners, yet powerful for advanced users.The complexity of the Chandra data require a flexible data analysis system which provides an environment where the users can apply our tools, but can also explore and construct their own applications. The main purpose of this talk is to present CIAO as a modern data analysis system for X-ray data analysis.CIAO has grown tremendously over the years and we will highlight (a) the most recent advancements with a particular emphasis on the newly developed high-level scripts which simplify the analysis steps for the most common cases making CIAO more accessible to all users - including beginners and users who are not X-ray astronomy specialists, (b) the python-based Sherpa modelling and fitting application and the new stand-alone version openly developed and distributed on Github and (c) progress on methods to

  12. An X-ray photoelectron spectroscopy study of the products of the interaction of gaseous IrF6 with fine UO2F2

    Directory of Open Access Journals (Sweden)

    Prusakov Vladimir N.

    2007-01-01

    Full Text Available Nuclear fuel reprocessing by fluorination, a dry method of regeneration of spent nuclear fuel, uses UO2F2 for the separation of plutonium from gaseous mixtures. Since plutonium requires special treatment, IrF6 was used as a thermodynamic model of PuF6. The model reaction of the interaction of gaseous IrF6 with fine UO2F2 in the sorption column revealed a change of color of the sorption column contents from pale-yellow to gray and black, indicating the formation of products of such an interaction. The X-ray photoelectron spectroscopy study showed that the interaction of gaseous IrF6 with fine UO2F2 at 125 °C results in the formation of stable iridium compounds where the iridium oxidation state is close to Ir3+. The dependence of the elemental compositions of the layers in the sorption column on the penetration depth of IrF6 was established.

  13. 21 CFR 1020.30 - Diagnostic x-ray systems and their major components.

    Science.gov (United States)

    2010-04-01

    ... computer processing of x-ray transmission data. Control panel means that part of the x-ray control upon... section, linear interpolation or extrapolation may be made. Positive means 2 shall be provided to ensure...

  14. Investigations of some regional river systems by INAA and X-ray fluorescence

    International Nuclear Information System (INIS)

    Drazhkovich, R.J.; Kukoch, A.

    1985-01-01

    Distribution of Zn, Hg, Sb, Cr, Fe, Sc and Co has been investigated in materials dissolved and suspended in the rivers Ibar, Zapadna Morava and Kamenica by means of INAA and X-ray fluorescence. Irradiation was made in VKG-channels of RA-nuclear reactor Vincha. Distribution coefficients were calculated, as well as contamination factors for investigated river regional systems in comparison to the uncontaminated water system. Data obtained indicate the possibility of utilization of these two analytical methods for investigation and control of biogeochemical and contamination processes in small regional water systems, especially important for modern studies in life sciences

  15. Comparative investigations of high resolution scanning systems for digitising X-ray films

    International Nuclear Information System (INIS)

    Wessel, H.; Rose, P.

    1992-01-01

    The visual or computer-aided evaluation of digitised X-ray films in non-destructive material testing requires highly sensitive scanning systems. They must be able to resolve differences in blackening and convert them into digital data without loss, if possible. Only in this way is the detection of the finest cracks in weld seams or contraction in areas of great sudden changes in blackening of cast parts guaranteed. In the context of this work, measurements were carried out which describe the reproduction properties of different scanning systems. After a short explanation of the different scanning systems, the results of the measurements are shown and evaluated. (orig.) [de

  16. Motion control system of MAX IV Laboratory soft x-ray beamlines

    International Nuclear Information System (INIS)

    Sjöblom, Peter; Lindberg, Mirjam; Forsberg, Johan; Persson, Andreas G.; Urpelainen, Samuli; Såthe, Conny

    2016-01-01

    At the MAX IV Laboratory, five new soft x-ray beamlines are under development. The first is Species and it will be used to develop and set the standard of the control system, which will be common across the facility. All motion axes at MAX IV will be motorized using stepper motors steered by the IcePAP motion controller and a mixture of absolute and incremental encoders following a predefined coordinate system. The control system software is built in Tango and uses the Python-based Sardana framework. The user controls the entire beamline through a synoptic overview and Sardana is used to run the scans.

  17. Motion control system of MAX IV Laboratory soft x-ray beamlines

    Energy Technology Data Exchange (ETDEWEB)

    Sjöblom, Peter, E-mail: peter.sjoblom@maxlab.lu.se; Lindberg, Mirjam, E-mail: mirjam.lindberg@maxlab.lu.se; Forsberg, Johan, E-mail: johan.forsberg@maxlab.lu.se; Persson, Andreas G., E-mail: andreas-g.persson@maxlab.lu.se; Urpelainen, Samuli, E-mail: samuli.urpelainen@maxlab.lu.se; Såthe, Conny, E-mail: conny.sathe@maxlab.lu.se [MAX IV Laboratory, Photongatan 2, 225 92 Lund (Sweden)

    2016-07-27

    At the MAX IV Laboratory, five new soft x-ray beamlines are under development. The first is Species and it will be used to develop and set the standard of the control system, which will be common across the facility. All motion axes at MAX IV will be motorized using stepper motors steered by the IcePAP motion controller and a mixture of absolute and incremental encoders following a predefined coordinate system. The control system software is built in Tango and uses the Python-based Sardana framework. The user controls the entire beamline through a synoptic overview and Sardana is used to run the scans.

  18. Timing and low-level rf system for an x-ray laser

    Directory of Open Access Journals (Sweden)

    Yuji Otake

    2016-02-01

    Full Text Available An x-ray free-electron laser (XFEL, SACLA, designed to open up new science, was constructed for generating coherent x rays with a peak power of more than 10 GW and a very short pulse of below 30 fs. This feature demands a very highly short-term temporal stability of less than 50 fs to the acceleration rf field of SACLA. For this reason, we developed a timing and low-level rf (LLRF system for SACLA based on that of the SPring8 compact SASE source (SCSS test accelerator for verifying the feasibility of an XFEL. The performance of the system using the in-phase and quadrature rf manipulation method was improved from SCSS’s system. Since the facility length of SACLA is 700 m, which is 10 times longer than that of the SCSS test accelerator, a phase-stabilized optical-fiber system designed to transmit time standard rf signals with low loss was also developed and deployed. This optical-fiber system equips fiber optical-length feedback control in order to mitigate environmental effects, such as temperature and humidity changes. On the other hand, the demanded maximum rf temporal stability is less than 50 fs, which is almost 10 times smaller than that of the SCSS test accelerator. Hence, reducing electric noise and increasing the temperature stability around timing and LLRF instruments were necessary and realized with a very low-noise power supply and a hemathermal 19-inch enclosure. The short-term temporal performance of the timing LLRF system finally attained a temporal stability of less than 13.6 fs in rms measured by a beam arrival-time measurement. This stability greatly helps to achieve the stable x-ray lasing of SACLA for routine operation during user experiments.

  19. Using x-ray computed tomography in hydrology: Systems, resolutions, and limitations

    DEFF Research Database (Denmark)

    Wildenschild, Dorthe; Hopmans, J.W.; Vaz, C.M.P.

    2002-01-01

    media, obtained with different scanning systems and sample sizes, to illustrate advantages and limitations of these various systems, including topics of spatial resolution and contrast. In addition, we present examples of our most recent three-dimensional high-resolution images, for which......A combination of advances in experimental techniques and mathematical analysis has made it possible to characterize phase distribution and pore geometry in porous media using non-destructive X-ray computed tomography (CT). We present qualitative and quantitative CT results for partially saturated...

  20. The research of the style of angel lobster eye x-ray optical system

    Science.gov (United States)

    Cheng, HuaQi; Liu, YuJiao; Zhang, ShaoWei; Hou, LinBao; Li, XingLong

    2018-01-01

    This paper has developed the theory research of wide field Angel lobster eye X-ray optical system based on the principle of entirely incidence. Combine the configuration characteristic of lobster eye, recommend the conclusion of beam of light focus on the half of radius whether point or parallel light. Designed the microchannel through the principle of real ray trace and got the relationship among different parameters about it using numerical value emulation. Got pixels and illumination pictures validated the wide field focus characteristic of Angel lobster eye by simulating the optical system.

  1. Implementation of a patient dose monitoring system in conventional digital X-ray imaging: initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Heilmaier, Christina; Zuber, Niklaus; Weishaupt, Dominik [Stadtspital Triemli Zurich, Department of Radiology and Nuclear Medicine, Zurich (Switzerland)

    2017-03-15

    The purpose was to report on the initial experience after implementation of a patient dose-monitoring system in conventional X-ray imaging. A dose-monitoring system collected dose data relating to different radiographs (one projection) and studies (two or more projections). Images were acquired on digital X-ray systems equipped with flat-panel detectors. During period 1, examinations were performed in a routine fashion in 12,614 patients. After period 1, technical modifications were performed and radiographers underwent training in radiation protection. During period 2, examinations were performed in 14,514 patients, and the radiographers were advised to read dose data after each radiograph/study. Dose data were compared by means of kerma area product (KAP, gray x centimetre squared) and entrance surface air kerma (ESAK, milligray). During period 1, 13,955 radiographs and 8,466 studies were performed, and in period 2 16,090 radiographs and 10,389 studies. In period 2, KAP values for radiographs were an average of 25 % lower and for studies 7 % lower, and ESAK values for radiographs were 24 % lower and for studies 5 % lower. The reduction in KAP was significant in 8/13 radiographs and in 6/14 studies, and the reduction in ESAK was significant in 6/13 radiographs and 5/14 studies. Implementation of a patient dose-monitoring system in conventional X-ray imaging allows easy data collection, supports dose reduction efforts, and may increase radiographers' dose awareness. (orig.)

  2. Combination use of lentinan with x-ray therapy in mouse experimental tumor system, (1)

    International Nuclear Information System (INIS)

    Shiio, Tsuyoshi; Tsuchiya, Yoshiharu; Ohishi, Kazuo; Yoshihama, Takashi

    1988-01-01

    Apparent reduction of leukocyte counts was observed in mice irradiated with 1,500 ∼ 3,000 rads of X-ray on the left hind leg. This reduction of leukocyto counts was completely protected by the pre-treatment with lentinan before X-ray irradiation. Suppressive effect of X-ray on the antitumor function of lentinan seems to be weak. When treatment with X-ray irradiation and lentinan was applied for mice bearing solid type sarcoma 180, additive effect was obtained by the combination of lentinan before or after X-ray irradiation. (author)

  3. Compact and portable X-ray imager system using Medipix3RX

    Science.gov (United States)

    Garcia-Nathan, T. B.; Kachatkou, A.; Jiang, C.; Omar, D.; Marchal, J.; Changani, H.; Tartoni, N.; van Silfhout, R. G.

    2017-10-01

    In this paper the design and implementation of a novel portable X-ray imager system is presented. The design features a direct X-ray detection scheme by making use of a hybrid detector (Medipix3RX). Taking advantages of the capabilities of the Medipix3RX, like a high resolution, zero dead-time, single photon detection and charge-sharing mode, the imager has a better resolution and higher sensitivity compared to using traditional indirect detection schemes. A detailed description of the system is presented, which consists of a vacuum chamber containing the sensor, an electronic board for temperature management, conditioning and readout of the sensor and a data processing unit which also handles network connection and allow communication with clients by acting as a server. A field programmable gate array (FPGA) device is used to implement the readout protocol for the Medipix3RX, apart from the readout the FPGA can perform complex image processing functions such as feature extraction, histogram, profiling and image compression at high speeds. The temperature of the sensor is monitored and controlled through a PID algorithm making use of a Peltier cooler, improving the energy resolution and response stability of the sensor. Without implementing data compression techniques, the system is capable of transferring 680 profiles/s or 240 images/s in a continuous mode. Implementation of equalization procedures and tests on colour mode are presented in this paper. For the experimental measurements the Medipix3RX sensor was used with a Silicon layer. One of the tested applications of the system is as an X-ray beam position monitor (XBPM) device for synchrotron applications. The XBPM allows a non-destructive real time measurement of the beam position, size and intensity. A Kapton foil is placed in the beam path scattering radiation towards a pinhole camera setup that allows the sensor to obtain an image of the beam. By using profiles of the synchrotron X-ray beam, high frequency

  4. H and D curves of screen--film systems: factors affecting their dependence on x-ray energy

    International Nuclear Information System (INIS)

    Vyborny, C.J.

    1979-01-01

    The sensitometric properties of radiographic screen--film systems are investigated with regard to their dependence on x-ray energy. Sensitometric measurements and a heuristic model for density formation are used to show that variation in the relative amount of light emitted by front and back screens may be the most important factor influencing the change in system H and D curves with x-ray energy

  5. X-ray beam-position feedback system with easy-to-use beam-position monitor.

    Science.gov (United States)

    Park, Jae Yeon; Kim, Yesul; Lee, Sangsul; Lim, Jun

    2018-05-01

    X-ray beam-position stability is indispensable in cutting-edge experiments using synchrotron radiation. Here, for the first time, a beam-position feedback system is presented that utilizes an easy-to-use X-ray beam-position monitor incorporating a diamond-fluorescence screen. The acceptable range of the monitor is above 500 µm and the feedback system maintains the beam position within 3 µm. In addition to being inexpensive, the system has two key advantages: it works without a scale factor for position calibration, and it has no dependence on X-ray energy, X-ray intensity, beam size or beam shape.

  6. The relationship between wave and geometrical optics models of coded aperture type x-ray phase contrast imaging systems.

    Science.gov (United States)

    Munro, Peter R T; Ignatyev, Konstantin; Speller, Robert D; Olivo, Alessandro

    2010-03-01

    X-ray phase contrast imaging is a very promising technique which may lead to significant advancements in medical imaging. One of the impediments to the clinical implementation of the technique is the general requirement to have an x-ray source of high coherence. The radiation physics group at UCL is currently developing an x-ray phase contrast imaging technique which works with laboratory x-ray sources. Validation of the system requires extensive modelling of relatively large samples of tissue. To aid this, we have undertaken a study of when geometrical optics may be employed to model the system in order to avoid the need to perform a computationally expensive wave optics calculation. In this paper, we derive the relationship between the geometrical and wave optics model for our system imaging an infinite cylinder. From this model we are able to draw conclusions regarding the general applicability of the geometrical optics approximation.

  7. Investigation of periodically driven systems by x-ray absorption spectroscopy using asynchronous data collection mode

    Science.gov (United States)

    Singh, H.; Donetsky, D.; Liu, J.; Attenkofer, K.; Cheng, B.; Trelewicz, J. R.; Lubomirsky, I.; Stavitski, E.; Frenkel, A. I.

    2018-04-01

    We report the development, testing, and demonstration of a setup for modulation excitation spectroscopy experiments at the Inner Shell Spectroscopy beamline of National Synchrotron Light Source - II. A computer algorithm and dedicated software were developed for asynchronous data processing and analysis. We demonstrate the reconstruction of X-ray absorption spectra for different time points within the modulation pulse using a model system. This setup and the software are intended for a broad range of functional materials which exhibit structural and/or electronic responses to the external stimulation, such as catalysts, energy and battery materials, and electromechanical devices.

  8. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  9. Measurement of the performance characteristics of diagnostic X-ray systems used in medicine

    International Nuclear Information System (INIS)

    1981-01-01

    A booklet has been produced by the Diagnostic Radiology Topic Group of the Hospital Physicists' Association, providing the basis for exhaustive performance tests on X-ray image intensifier television systems. After a general introduction to the equipment, the parameters which may need to be assessed are outlined in section 1. The measurement techniques and equipment necessary to undertake the measurements are presented in section 2. Specimen data sheets are also presented which the user may find useful to record the data acquired in the field. (U.K.)

  10. Measuring system with stereoscopic x-ray television for accurate diagnosis

    International Nuclear Information System (INIS)

    Iwasaki, K.; Shimizu, S.

    1987-01-01

    X-ray stereoscopic television is diagnostically effective. The authors invented a measuring system using stereoscopic television whereby the coordinates of any two points and their separation can be measured in real time without physical contact. For this purpose, the distances between the two foci of the tube and between the tube and image intensifier were entered into a microcomputer beforehand, and any two points on the CRT stereoscopic image can be defined through the stereoscopic spectacles. The coordinates and distance are then displayed on the CRT monitor. By this means, measurements such as distance between vessels and size of organs are easily made

  11. A novel process control method for a TT-300 E-Beam/X-Ray system

    Science.gov (United States)

    Mittendorfer, Josef; Gallnböck-Wagner, Bernhard

    2018-02-01

    This paper presents some aspects of the process control method for a TT-300 E-Beam/X-Ray system at Mediscan, Austria. The novelty of the approach is the seamless integration of routine monitoring dosimetry with process data. This allows to calculate a parametric dose for each production unit and consequently a fine grain and holistic process performance monitoring. Process performance is documented in process control charts for the analysis of individual runs as well as historic trending of runs of specific process categories over a specified time range.

  12. Development of X-ray mini-probes for the Digiray RGX system

    International Nuclear Information System (INIS)

    Wojcik, R.; Kross, B.; Majewski, L.; Majewski, S.; Weisenberger, A.G.; Zorn, C.; Birt, E.A.; Parker, F.R.; Winfree, W.P.; Albert, R.D.; Albert, T.M.

    1994-01-01

    We have developed and tested a variety of X-ray mini-probes for the Reverse Geometry X-radiography trademark ,1 (RGX) system each having their own advantages and disadvantages. These mini-probes consist of small scintillators (as small as 2 mm in diameter and 5 mm long) attached to optical light guides (as long as 14 m) coupled to photomultipliers. Images produced with these probes show that even smaller probes and/or longer light guides may be fashioned. Such probes may be useful in both non-destructive evaluation and medical imaging. ((orig.))

  13. The data acquisition system for the Leeds Infirmary MWPC X-ray imaging detector

    International Nuclear Information System (INIS)

    Quinton, S.; Gibbings, D.; Jones, D.; Norton, H.

    1979-10-01

    An electronic system is described which is designed to acquire and process data from a MWPC X-ray imaging detector. Two dimensional information from the chamber is obtained by using cathode plane delay-line readout. A single crate CAMAC assembly is used as the chamber-computer interface. The use of control source units for the delay line scalers and TV display driver functions together with an intermediate memory in the crate allows input data rates up to 1MHz and TV display facilities without constant computer refreshing. (author)

  14. A photodiode amplifier system for pulse-by-pulse intensity measurement of an x-ray free electron laser.

    Science.gov (United States)

    Kudo, Togo; Tono, Kensuke; Yabashi, Makina; Togashi, Tadashi; Sato, Takahiro; Inubushi, Yuichi; Omodani, Motohiko; Kirihara, Yoichi; Matsushita, Tomohiro; Kobayashi, Kazuo; Yamaga, Mitsuhiro; Uchiyama, Sadayuki; Hatsui, Takaki

    2012-04-01

    We have developed a single-shot intensity-measurement system using a silicon positive-intrinsic-negative (PIN) photodiode for x-ray pulses from an x-ray free electron laser. A wide dynamic range (10(3)-10(11) photons/pulse) and long distance signal transmission (>100 m) were required for this measurement system. For this purpose, we developed charge-sensitive and shaping amplifiers, which can process charge pulses with a wide dynamic range and variable durations (ns-μs) and charge levels (pC-μC). Output signals from the amplifiers were transmitted to a data acquisition system through a long cable in the form of a differential signal. The x-ray pulse intensities were calculated from the peak values of the signals by a waveform fitting procedure. This system can measure 10(3)-10(9) photons/pulse of ~10 keV x-rays by direct irradiation of a silicon PIN photodiode, and from 10(7)-10(11) photons/pulse by detecting the x-rays scattered by a diamond film using the silicon PIN photodiode. This system gives a relative accuracy of ~10(-3) with a proper gain setting of the amplifiers for each measurement. Using this system, we succeeded in detecting weak light at the developmental phase of the light source, as well as intense light during lasing of the x-ray free electron laser. © 2012 American Institute of Physics

  15. A novel lobster-eye imaging system based on Schmidt-type objective for X-ray-backscattering inspection

    International Nuclear Information System (INIS)

    Xu, Jie; Wang, Xin; Zhan, Qi; Huang, Shengling; Chen, Yifan; Mu, Baozhong

    2016-01-01

    This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system based on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm.

  16. Smart x-ray beam position monitor system for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Shu, D.; Kuzay, T.

    1996-01-01

    In third-generation synchrotron radiation sources, such as the Advanced Photon Source (APS), the sensitivity and reliability requirements for the x-ray beam position monitors (XBPMs) are much higher than for earlier systems. Noise and contamination signals caused by radiation emitted from the bending magnet become a major problem. The regular XBPM calibration process can only provide signal correction for one set of conditions for the insertion devices (ID). During normal operation, parameters affecting the ID-emitted beam, such as the gap of the ID magnets and the beam current, are the variables. A new smart x-ray beam position monitor system (SBPM) has been conceived and designed for the APS. It has a built in self-learning structure with EEPROM memory that is large enough to open-quote open-quote remember close-quote close-quote a complete set of calibration data covering all the possible operating conditions. During the self-learning mode, the monitor system initializes a series of automatic scan motions with information for different ID setups and records them into the database array. During normal operation, the SBPM corrects the normalized output according to the ID setup information and the calibration database. So that, with this novel system, the SBPM is always calibrating itself with the changing ID set up conditions. copyright 1996 American Institute of Physics

  17. An automated x-ray stress measurement system using a microcomputer

    International Nuclear Information System (INIS)

    Kurita, Masanori; Miyagawa, Matsuo; Sato, Fumiyoshi; Sugiharai, Shigeru; Ishii, Masami; Sumiyoshi, Michio.

    1985-01-01

    An automated system for a rapid and precise X-ray stress measurement using a microcomputer has been developed. A block diagram of the system and a flowchart for the stress measurement method are shown. Of the various methods, the one most suitable for the material to be measured can be programmed in this system. The residual stress in a hardened steel having a broad diffraction profile (half-width of 7.2 deg ) could be measured in six minutes with a small standard deviation of 13 MPa by the Gaussian curve method using the sin 2 ψ method. Both the oscillation and the fixed ψ methods, using the Gaussian curve method, allow the X-ray stress measurement of coarse-grained steels; the sin 2 ψ diagram obtained by these methods had a good linearity. The residual stress measurement of an annealed chromium powder gave almost zero stress values, -3.2 to 2.9 MPa depending on the method used, showing a high accuracy of the system. (author)

  18. High-pressure behavior of α-boron studied on single crystals by X-ray diffraction, Raman and IR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chuvashova, Irina, E-mail: irina.chuvashova@gmail.com [Material Physics and Technology at Extreme Conditions, Laboratory of Crystallography, University of Bayreuth, D-95440 Bayreuth (Germany); Bayerisches Geoinstitut, University of Bayreuth, D-95440 Bayreuth (Germany); Bykova, Elena; Bykov, Maxim [Bayerisches Geoinstitut, University of Bayreuth, D-95440 Bayreuth (Germany); Svitlyk, Volodymyr [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Gasharova, Biliana [Institute for Photon Science and Synchrotron Radiation, Karlsruhe Institute of Technology, P.O. Box 3640, 76021 Karlsruhe (Germany); IBPT, Karlsruhe Institute of Technology, P.O. Box 3640, 76021 Karlsruhe (Germany); Mathis, Yves-Laurent [ANKA Synchrotron Radiation Facility, Karlsruhe Institute of Technology, P.O. Box 3640, 76021 Karlsruhe (Germany); IBPT, Karlsruhe Institute of Technology, P.O. Box 3640, 76021 Karlsruhe (Germany); Caracas, Razvan [CNRS, Laboratoire de Géologie de Lyon, ENS de Lyon, UCBL Lyon 1, Université de Lyon (France); Dubrovinsky, Leonid [Bayerisches Geoinstitut, University of Bayreuth, D-95440 Bayreuth (Germany); Dubrovinskaia, Natalia [Material Physics and Technology at Extreme Conditions, Laboratory of Crystallography, University of Bayreuth, D-95440 Bayreuth (Germany)

    2017-01-15

    In the present study single crystals of rhombohedral α-B were investigated under pressure to 60 GPa by means of single-crystal X-ray diffraction. The bulk modulus of α-B was found to be K=224(7) GPa (K′=3.0(3)). Measurements of interatomic distances as a function of pressure revealed that the intericosahedral two-center two-electron (2c–2e) bonds are almost as stiff as some of intraicosahedral ones. The three-center two-electron (3c–2e) intericosahedral bonds show much higher compliance compared to other bonds in α-B. The vibrational properties of α-B under pressure were investigated by Raman spectroscopy at pressures up to 160 GPa and IR spectroscopy at pressures up to 53 GPa. - Graphical abstract: The rhombohedral α-B is highly incompressible and extremely stable: it maintains its crystal structure up to 160 GPa and its intericosahedral 2e2c bonds are almost as stiff as some of intraicosahedral ones. - Highlights: • Structural stability of α-B has been investigated up to 160 GPa on single crystals. • Single-crystal x-ray diffraction reveals that α-B is highly incompressible. • Compressibility of B{sub 12} icosahedra is considerably lower than that of the bulk material. • Intericosahedral 2e2c bonds are almost as stiff as some of intraicosahedral ones.

  19. Luminescence of Er3+ doped double lead halide crystals under X-ray, UV, VIS and IR excitation

    Science.gov (United States)

    Serazetdinov, A. R.; Smirnov, A. A.; Pustovarov, V. A.; Isaenko, L. I.

    2017-09-01

    Er3+ doped double lead halide crystals incorporate a number of properties making them interesting for practical use in light conducting materials. X-ray excited luminescence (XRL) spectra, photoluminescence (PL) spectra in region of 1.5-3.5 eV, photoluminescence excitation (PLE) spectra (2.75-5 eV) and anti-stokes luminescence (ASL) spectra were measured at room temperature in KPb2Cl5 (KPC) and RbPb2Br5 (RPB) matrices doped with Er3+ (1%) ions and in KPC doped with Er3++ Yb3+ ions(1:3 ratio concentration). Intraconfigurational f→f transitions are observed in Er3+ ions in most of the cases. The concrete spectrum form is strongly dependent on the excitation energy. Under 980 nm excitation upper Er3+ levels are excited, showing upconversional processes. In case of 313 nm (UV) and 365 nm (VIS) excitation self trapped exciton luminescence was detected in RPB crystal. Additional Yb3+ doping ions strongly increase quantum yield under 980 nm excitation and this doping cause insignificant influence on quantum yield under VIS or UV excitation.

  20. Analyze for the Quality Control of General X-ray Systems in Capital region

    International Nuclear Information System (INIS)

    Kang, Byung Sam; Lee, Kang Min; Shin, Woo Yong; Park, Soon Chul; Choi, Hak Dong; Cho, Yong Kwon

    2012-01-01

    Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

  1. Improving Soft X-Ray Spectral Irradiance Models for Use Throughout the Solar System

    Science.gov (United States)

    Eparvier, F. G.; Thiemann, E.; Woods, T. N.

    2017-12-01

    Understanding the effects of solar variability on planetary atmospheres has been hindered by the lack of accurate models and measurements of the soft x-ray (SXR) spectral irradiance (0-6 nm). Most measurements of the SXR have been broadband and are difficult to interpret due to changing spectral distribution under the pass band of the instruments. Models that use reference spectra for quiet sun, active region, and flaring contributions to irradiance have been made, but with limited success. The recent Miniature X-ray Solar Spectrometer (MinXSS) CubeSat made spectral measurements in the 0.04 - 3 nm range from June 2016 to May 2017, observing the Sun at many different levels of activity. In addition, the Solar Dynamics Observatory (SDO) EUV Variability Experiment (EVE) has observed the Sun since May 2010, in both broad bands (including a band at 0-7 nm) and spectrally resolved (6-105 nm at 0.1 nm resolution). We will present an improved model of the SXR based on new reference spectra from MinXSS and SDO-EVE. The non-flaring portion of the model is driven by broadband SXR measurements for determining activity level and relative contributions of quiet and active sun. Flares are modeled using flare temperatures from the GOES X-Ray Sensors. The improved SXR model can be driven by any sensors that provide a measure of activity level and flare temperature from any vantage point in the solar system. As an example, a version of the model is using the broadband solar irradiance measurements from the MAVEN EUV Monitor at Mars will be presented.

  2. Improvement way for mobile X-ray examinations by rule revision about safety management of diagnosis radiation occurrence system

    International Nuclear Information System (INIS)

    Choi, Jun Gu; Kim, Gyeong Su; Kim, Byeong Gi; Ahn, Nam Jun; Kim, Hyeong Sun; Kim, Sang Geon; Lim, Si Eun

    2007-01-01

    A safety management rule of the diagnosis radiation system which opened a court 2006 February 10th was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this study is to minimize injury by radiation that can happen to patients and people around a sick ward when managing mobile X-ray system. This study analyzed sickroom environment of mobile X-ray examination and the statistical data of the Konkuk medical Information System (KIS) and the Picture Archiving Communication System (PACS). This study also investigated patient conditions, infection, relation information and related data, when the sickroom mobile X-ray examination is used. Through data analysis, many problems were expected such as restriction of space side, manpower and expense of business side, satisfaction degree decline of patient and protector of operation side. Therefore, we tried to restrict examination of multi bed sickroom, and to use treatment room in each ward to solve problem mentioned. As a result, the whole sickroom mobile X-ray examination rate decreased to near 50%, and mobile X-ray examination rate for inpatients decreased to more than 85%. This study shows that several attempts we did should be helpful for manpower, patients satisfaction and expenses. Also, they should protect patients in sickroom from unnecessary radiation exposure and could minimize inconvenience of patients and their family members from x-ray examination

  3. An operational 150 kV microfocus rod anode X-ray system for nondestructive testing

    International Nuclear Information System (INIS)

    Fontijn, E.A.

    1978-01-01

    This paper describes an operational state of the art 150 kV microfocus rod anode X-ray system having ultra-high radiographic resolution capabilities. A cocal spot size of 0.050 mm is provided. Heretofore unattainable long rod anode lengths coupled with very small diameters are now possible using mini-magnetic lens technology. Over-all rod anode diameters as small as 9 mm with useful lengths of 1 m or more are possible, permitting panoramic inspections where previously only lower resolution radioisotope radiographic techniques were possible. Radiographic sensitivity of better than 1% has been reported with film-focal-distances on the order of 8 mm through 3 mm of steel. The system has been successfully applied to steam generator and heat exchanger tube-to-tubesheet weldments in both Europe and the USA. Other application areas include marine and aircraft jet engine inspection and numerous other applications where high reliability requirements indicate the use of a ultra-sensitive radiographic technique as is routinely demonstrated with the 150 kV Microfocus Rod Anode X-ray System. (orig.) [de

  4. Characterizing morphology in organic systems with resonant soft X-ray scattering

    International Nuclear Information System (INIS)

    Carpenter, Joshua H.; Hunt, Adrian; Ade, Harald

    2015-01-01

    Highlights: • A brief history of the development of R-SoXS for studying soft matter systems. • A theoretical background and an overview of analysis methodology. • Applications to block copolymers, organic electronics, and biological systems. • A discussion of emerging applications and an outlook on the future of R-SoXS. - Abstract: Resonant soft X-ray scattering (R-SoXS) has proven to be a highly useful technique for studying the morphology of soft matter thin films due to the large intrinsic contrast between organic materials and the anisotropic nature of the resonant electronic state transitions from which the contrast originates. This allows R-SoXS users to measure spatial composition correlations from crystalline and amorphous phases in heterogeneous organic samples, infer relative domain purity, and determine average local molecular ordering correlations. R-SoXS has been used to study the morphology of organic photovoltaics, organic thin film transistors, biological systems, and block copolymer engineering applications. The mesoscopic morphological information compliments molecular packing information determined with hard X-rays, so that complex structure–property relationships can be elucidated over a large range of length scales. Extensions of R-SoXS have also emerged that make use of more advanced sample setups or different experimental geometries than normal transmission, such as θ–2θ reflectivity or grazing incidence.

  5. Soft x-ray backlighting of cryogenic implosions using a narrowband crystal imaging system (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Stoeckl, C., E-mail: csto@lle.rochester.edu; Bedzyk, M.; Brent, G.; Epstein, R.; Fiksel, G.; Guy, D.; Goncharov, V. N.; Hu, S. X.; Ingraham, S.; Jacobs-Perkins, D. W.; Jungquist, R. K.; Marshall, F. J.; Mileham, C.; Nilson, P. M.; Sangster, T. C.; Shoup, M. J.; Theobald, W. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States)

    2014-11-15

    A high-performance cryogenic DT inertial confinement fusion implosion experiment is an especially challenging backlighting configuration because of the high self-emission of the core at stagnation and the low opacity of the DT shell. High-energy petawatt lasers such as OMEGA EP promise significantly improved backlighting capabilities by generating high x-ray intensities and short emission times. A narrowband x-ray imager with an astigmatism-corrected bent quartz crystal for the Si He{sub α} line at ∼1.86 keV was developed to record backlit images of cryogenic direct-drive implosions. A time-gated recording system minimized the self-emission of the imploding target. A fast target-insertion system capable of moving the backlighter target ∼7 cm in ∼100 ms was developed to avoid interference with the cryogenic shroud system. With backlighter laser energies of ∼1.25 kJ at a 10-ps pulse duration, the radiographic images show a high signal-to-background ratio of >100:1 and a spatial resolution of the order of 10 μm. The backlit images can be used to assess the symmetry of the implosions close to stagnation and the mix of ablator material into the dense shell.

  6. Description of x-ray-fluorescence (XRF) system for the Wet Scrap Development Laboratory (WSDL)

    International Nuclear Information System (INIS)

    Jedlovec, D.R.

    1981-06-01

    In support of the process control and accountability needs of the Wet Scrap Design Laboratory (WSDL), a technique utilizing X-ray Fluorescence (XRF) to determine actinide concentrations was developed and tested in FY 80, FY 81 at the General Electric Vallecitos Nuclear Center (GE-VNC). XRF analysis of uranium and plutonium solutions representative of those expected from the wet chemical processes of the WSDL was performed. This contract was to develop, test, and demonstrate control system concepts to provide a basis for an Integrated Control System (ICS) for a COPRECAL Conversion Plant. Financial support to the ICS was withdrawn before any x-ray fluorescence plutonium testing and development work could be accomplished. The following XRF testing and operation were performed at GE-VNC in FY 80, FY 81: uranium, plutonium, U/Pu testing completed September 1980; in-line testing completed October 1980; high concentration testing completed October 1980; shipment of XRF system components to W-HEDL accomplished January 1981

  7. Characteristics of high-energy X-rays using computed radiography systems

    International Nuclear Information System (INIS)

    Matsumoto, Mitsuhiro; Mori, Yoshinobu

    1993-01-01

    A computed radiography (CR) with storage phosphor technology has advanced remarkably. Its application has been also discussed regarding the field of radiotherapy and studies have been made to shift from the film/screen system to the portal film using the CR system. The authors started to research CR portal imaging with high energy X-ray (10MV) on a regular scale in 1989. This paper deals with characteristics of high energy X-rays using the CR system. The digital characteristic curve corresponded with calculated value for dynamic range (L-value). The monitor unit (MU) counts at pixel (digital) value saturation point were L-value 0.5:28 MU, L-value 1.0:50 MU, L-value 2.0:167 MU, L-value 3.0:450 MU, L-value 4.0:1614 MU. The image contrast with the Mix-Dp phantom was L-value 0.5: about a 300 pixel value and L-value 4.0: about a 30 pixel value by a phantom 10 to 18 cm in thickness. Optimum L-value was 0.5, and tone-scale was the straight type of CR portal imaging using the graphy count mode. Optimum L-value was 4.0, and tone-scale was a rectangular wave type of CR portal imaging using therapeutic doses, and those were also described by the histogram analysis. (author)

  8. System Characterizations and Optimized Reconstruction Methods for Novel X-ray Imaging Modalities

    Science.gov (United States)

    Guan, Huifeng

    In the past decade there have been many new emerging X-ray based imaging technologies developed for different diagnostic purposes or imaging tasks. However, there exist one or more specific problems that prevent them from being effectively or efficiently employed. In this dissertation, four different novel X-ray based imaging technologies are discussed, including propagation-based phase-contrast (PB-XPC) tomosynthesis, differential X-ray phase-contrast tomography (D-XPCT), projection-based dual-energy computed radiography (DECR), and tetrahedron beam computed tomography (TBCT). System characteristics are analyzed or optimized reconstruction methods are proposed for these imaging modalities. In the first part, we investigated the unique properties of propagation-based phase-contrast imaging technique when combined with the X-ray tomosynthesis. Fourier slice theorem implies that the high frequency components collected in the tomosynthesis data can be more reliably reconstructed. It is observed that the fringes or boundary enhancement introduced by the phase-contrast effects can serve as an accurate indicator of the true depth position in the tomosynthesis in-plane image. In the second part, we derived a sub-space framework to reconstruct images from few-view D-XPCT data set. By introducing a proper mask, the high frequency contents of the image can be theoretically preserved in a certain region of interest. A two-step reconstruction strategy is developed to mitigate the risk of subtle structures being oversmoothed when the commonly used total-variation regularization is employed in the conventional iterative framework. In the thirt part, we proposed a practical method to improve the quantitative accuracy of the projection-based dual-energy material decomposition. It is demonstrated that applying a total-projection-length constraint along with the dual-energy measurements can achieve a stabilized numerical solution of the decomposition problem, thus overcoming the

  9. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  10. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  11. Generation and application of soft-X-ray by means of inverse compton scattering between high quality election beam and IR laser

    International Nuclear Information System (INIS)

    Washio, M.; Sakaue, K.; Hama, Y.; Kamiya, Y.; Moriyama, R.; Hezume, K.; Saito, T.; Kuroda, R.; Kashiwagi, S.; Ushida, K.; Hayano, H.; Urakawa, J.

    2006-01-01

    High quality beam generation project based on High-Tech Research Center Project, which has been approved by Ministry of Education, Culture, Sports, Science and Technology in 1999, has been conducted by advance research institute for science and engineering, Waseda University. In the project, laser photo-cathode RF-gun has been selected for the high quality electron beam source. RF cavities with low dark current, which were made by diamond turning technique, have been successfully manufactured. The low emittance electron beam was realized by choosing the modified laser injection technique. The obtained normalized emittance was about 3 mm·mrad at 100 pC of electron charge. The soft X-ray beam generation with the energy of 370 eV, which is in the energy region of so-called 'water window', by inverse Compton scattering has been performed by the collision between IR laser and the low emittance electron beams. (authors)

  12. First result from x-ray pulse height analyzer with radial scanning system for LHD

    Science.gov (United States)

    Muto, Sadatsugu; Morita, Shigeru

    2001-01-01

    Radial profiles of x-ray spectrum have been successfully obtained using an assembly of x-ray pulse height analyzer in large helical device. The observed profile is obtained from plasma heated by ICRF and neutral beam injection (NBI). As a detector, Si(Li) semiconductor is used with a histogramming memory and analog-to-digital converter (ADC) basically working at high counting rate up to 500 kcps. In routine operation a count rate of 62 kcps has been normally obtained with energy resolution better than 400 eV at iron Kα line. The assembly is equipped with four detectors and a radial scanning system which modulates sight lines of the detectors in major radius direction. The profiles of electron temperature and the intensity of metallic impurities have been obtained with a spatial resolution of a few centimeters. Measured electron temperature is in good agreement with that from Thomson scattering. The system is applicable to steady-state discharge. The design philosophy of the assembly and recent results on the performance tests are also presented.

  13. Active interlock system for high power insertion devices in the x-ray ring

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    In modern synchrotron radiation rings photon beams generated by high power insertion devices (IDs) may be sufficiently intense to cause severe thermal damage to the machine vacuum chamber if mis-steered. Thus when operating a storage ring with the IDs, great care must be exercised to prevent mis-steering of the electron beam orbit. At present, the X-ray ring operates with three IDs, namely two hybrid wigglers (HBW) at X-21 and X-25,a nd a 5-Tesla superconducting wiggler at X-17. All wigglers are located in low-beta straight sections. In the straight sections. In the straight sections, beam orbit may be deflected by as much as ±8 mrad without scraping the chamber wall. For various reasons it was not possible to design the X-ray ring vacuum chamber to be safe under all possible operating conditions, however, the chamber is safe for i < 7 mA, all horizontal beam deflection angles and for vertical angles < ± 2.5 mrad. To protect the machine vacuum chamber from damage due to mis-steered beams, and interlock system has been developed and installed. This system utilizes active beam position detectors which continuously monitor beam motion in each of the ID straight sections and logic circuitry which interrupts the RF and dumps the stored beam in the case of a fault

  14. Building a Graphite Calorimetry System for the Dosimetry of Therapeutic X-ray Beams

    Directory of Open Access Journals (Sweden)

    In Jung Kim

    2017-06-01

    Full Text Available A graphite calorimetry system was built and tested under irradiation. The noise level of the temperature measurement system was approximately 0.08 mK (peak to peak. The temperature of the core part rose by approximately 8.6 mK at 800 MU (monitor unit for 6-MV X-ray beams, and it increased as X-ray energy increased. The temperature rise showed less spread when it was normalized to the accumulated charge, as measured by an external monitoring chamber. The radiation energy absorbed by the core part was determined to have values of 0.798 J/μC, 0.389 J/μC, and 0.352 J/μC at 6 MV, 10 MV, and 18 MV, respectively. These values were so consistent among repeated runs that their coefficient of variance was less than 0.15%.

  15. High pressure x-ray diffraction studies on U-Al systems

    International Nuclear Information System (INIS)

    Sahu, P.Ch.; Chandra Shekar, N.V.; Subramanian, N.; Yousuf, Mohammad; Govinda Rajan, K.

    1995-01-01

    In this paper, high pressure x-ray diffraction studies of the three U-Al compounds, namely, UAl 2 , UAl 3 and UAl 4 are presented. The experiments are carried out using a unique diamond anvil high pressure x-ray diffraction system in the Guinier geometry up to a maximum pressure of ∼ 35 GPa. The compressibility behaviour of UAl 2 is consistent with its itinerant 5f states, whereas that of UAl 3 and UAl 4 indicate more towards their localized nature. Among these three compounds, a structural phase transition in UAl 2 has been observed at ∼ 11 GPa and the structure of the high pressure phase has been identified to be of MgNi 2 type with space group P6 3 /mmc. The structure of UAl 2 at NTP is of MgCu 2 type with space group Fd3m. From the electron to atom ratio (e/α) consideration, another structural phase transition, namely, MgNi 2 -MgCu 2 at a higher pressure is proposed. Further, on a similar consideration, a new pressure induced structural sequence, namely, MgCu 2 -MgNi 2 (or MgZn 2 -MgCu 2 ) in the AB 2 type compounds of the f electron based systems is suggested. (author)

  16. Development of X-ray diffractometers XD-D1 AI qualitative analysis system

    International Nuclear Information System (INIS)

    Arai, Hiroshi; Uota, Atsushi; Ishida, Hidenobu

    1994-01-01

    Qualitative X-ray diffraction is a very important analytical method, however, it is also very difficult to perform and needs some special skills. Also, the analysis accuracy depends on the operators' knowledge of qualitative analysis. In order that even a beginner analyst can obtain accurate results, we have developed the 'XD-D1 AI Qualitative Analysis System'. This system can support analytical operations with the experts' knowledge made available by AI techniques. Systematizing the experts' knowledge, we applied the system to our expert shell 'GENZO-I/PRO'. This system enabled a beginner analyst to get the same results as a specialist would get. In this paper, we will describe the process of system design, system construction and an example analysis. (author)

  17. Comparative investigation of Fourier transform infrared (FT-IR) spectroscopy and X-ray diffraction (XRD) in the determination of cotton fiber crystallinity.

    Science.gov (United States)

    Liu, Yongliang; Thibodeaux, Devron; Gamble, Gary; Bauer, Philip; VanDerveer, Don

    2012-08-01

    Despite considerable efforts in developing curve-fitting protocols to evaluate the crystallinity index (CI) from X-ray diffraction (XRD) measurements, in its present state XRD can only provide a qualitative or semi-quantitative assessment of the amounts of crystalline or amorphous fraction in a sample. The greatest barrier to establishing quantitative XRD is the lack of appropriate cellulose standards, which are needed to calibrate the XRD measurements. In practice, samples with known CI are very difficult to prepare or determine. In a previous study, we reported the development of a simple algorithm for determining fiber crystallinity information from Fourier transform infrared (FT-IR) spectroscopy. Hence, in this study we not only compared the fiber crystallinity information between FT-IR and XRD measurements, by developing a simple XRD algorithm in place of a time-consuming and subjective curve-fitting process, but we also suggested a direct way of determining cotton cellulose CI by calibrating XRD with the use of CI(IR) as references.

  18. A triboelectric closed loop band system for the generation of x-rays

    Science.gov (United States)

    Van Cleve, E.; Lucas, B.; Ganlieli, Z.; Wong, E. W.; Cortes, P.; Mehta, N.; Cuadra, D.; Fong, J.; Hansen, S.; Kotowski, A.; Camara, C. G.

    2015-08-01

    X-ray have been commercially produced using the same basic design since their discovery by Wilhelm Roentgen in 1895, for which he was awarded the first Nobel prize in physics. This technology requires high voltage elements, ultra high vacuum tubes, and high voltage electronics. The vacuum and high voltage drive up the price of x-ray technology and in order to bring down the cost, a brand new way to produce x-rays is needed. In 2008 Carlos Camara, Juan Escobar, Jonathan R. Hird, and Seth Putterman1 discovered that by pealing scotch tape in a vacuum you could create enough x-rays to take an x-ray radiograph of a finger. This lead to the formation of Tribogenics and the development of the rod and band x-ray architecture.

  19. Automatic local beam steering systems for NSLS x-ray storage ring: Design and implementation

    International Nuclear Information System (INIS)

    Singh, O.V.; Nawrocky, R.; Flannigan, J.

    1991-01-01

    Recently, two local automatic steering systems, controlled by microprocessors, have been installed and commissioned in the NSLS X- Ray storage ring. In each system, the position of the electron beam is stabilized at two locations by four independent servo systems. This paper describes three aspects of the local feedback program: design; commissioning; and limitation. The system design is explained by identifying major elements such as beam position detectors, signal processors, compensation amplifiers, ratio amplifiers, trim equalizers and microprocessor feedback controllers. System commissioning involves steps such as matching trim compensation, determination of local orbit bumps, measurement of open loop responses and design of servo circuits. Several limitations of performance are also discussed. 7 refs., 2 figs

  20. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  1. A synchrotron radiation camera and data acquisition system for time resolved x-ray scattering studies

    International Nuclear Information System (INIS)

    Bordas, J.; Koch, M.H.J.; Clout, P.N.; Dorrington, E.; Boulin, C.; Gabriel, A.

    1980-01-01

    Until recently, time resolved measurements of x-ray scattering patterns have not been feasible because laboratory x-ray sources were too weak and detectors unavailable. Recent developments in both these fields have changed the situation, and it is now possible to follow changes in x-ray scattering patterns with a time resolution of a few ms. The apparatus used to achieve this is described and some examples from recent biological experiments are given. (author)

  2. Vacuum system design for a superconducting X-ray lithography light source

    International Nuclear Information System (INIS)

    Schuchman, J.C.

    1990-01-01

    A superconducting electron storage ring for X-ray lithography (SXLS) is to be built at Brookhaven National Laboratory (BNL). The goal is to design and construct a light source specifically dedicated to X-ray lithography production and which would be used as a prototype in a technology transfer to American industry. The machine will be built in two phases: phase I, a low energy ring (200 MeV, 500 mA) using all room temperature magnets which will be used primarily for low energy injection studies. Phase II will be a full energy machine (690 MeV, 500 mA) where the room temperature 180 0 dipole magnets of phase I will be replaced with superconducting magnets. The machine, with a racetrack shape and a circumference of 8.5 m, is designed to be portable and replaceable as a single unit. This paper will discuss the vacuum system design for both phases; i.e. gas desorption, warm bore vs cold bore, ion trapping, clearing electrodes, and diagnostic instrumentation. (author)

  3. Discovery of radio emission from the symbiotic X-ray binary system GX 1+4

    Science.gov (United States)

    van den Eijnden, J.; Degenaar, N.; Russell, T. D.; Miller-Jones, J. C. A.; Wijnands, R.; Miller, J. M.; King, A. L.; Rupen, M. P.

    2018-02-01

    We report the discovery of radio emission from the accreting X-ray pulsar and symbiotic X-ray binary GX 1+4 with the Karl G. Jansky Very Large Array. This is the first radio detection of such a system, wherein a strongly magnetized neutron star accretes from the stellar wind of an M-type giant companion. We measure a 9 GHz radio flux density of 105.3 ± 7.3 μJy, but cannot place meaningful constraints on the spectral index due to a limited frequency range. We consider several emission mechanisms that could be responsible for the observed radio source. We conclude that the observed properties are consistent with shocks in the interaction of the accretion flow with the magnetosphere, a synchrotron-emitting jet, or a propeller-driven outflow. The stellar wind from the companion is unlikely to be the origin of the radio emission. If the detected radio emission originates from a jet, it would show that strong magnetic fields (≥1012 G) do not necessarily suppress jet formation.

  4. Theory and Modelling of Ultrafast X-ray Imaging of Dynamical Non-equilibrium Systems

    DEFF Research Database (Denmark)

    Lorenz, Ulf

    Over the next few years, a new generation of x-ray sources is going online. These freeelectron lasers will provide extremely bright subpicosecond x-ray pulses. Traditionally, x-ray diraction has the advantage of directly determining the atomic positions within a sample. With these new machines......, it becomes feasible to exploit this concept for ultrafast processes; in eect, we can study chemical reactions as they occur. This thesis deals with theoretical aspect of ultrafast time-resolved x-ray diraction (TRXD).We derive general formulas for calculating the diraction signal that are closely related...

  5. A one-dimensional ion beam figuring system for x-ray mirror fabrication

    International Nuclear Information System (INIS)

    Idir, Mourad; Huang, Lei; Bouet, Nathalie; Kaznatcheev, Konstantine; Vescovi, Matthew; Lauer, Ken; Conley, Ray; Rennie, Kent; Kahn, Jim; Nethery, Richard; Zhou, Lin

    2015-01-01

    We report on the development of a one-dimensional Ion Beam Figuring (IBF) system for x-ray mirror polishing. Ion beam figuring provides a highly deterministic method for the final precision figuring of optical components with advantages over conventional methods. The system is based on a state of the art sputtering deposition system outfitted with a gridded radio frequency inductive coupled plasma ion beam source equipped with ion optics and dedicated slit developed specifically for this application. The production of an IBF system able to produce an elongated removal function rather than circular is presented in this paper, where we describe in detail the technical aspect and present the first obtained results

  6. A one-dimensional ion beam figuring system for x-ray mirror fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Idir, Mourad, E-mail: midir@bnl.gov; Huang, Lei; Bouet, Nathalie; Kaznatcheev, Konstantine; Vescovi, Matthew; Lauer, Ken [NSLS-II, Brookhaven National Laboratory, P.O. Box 5000, Upton, New York 11973 (United States); Conley, Ray [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Rennie, Kent; Kahn, Jim; Nethery, Richard [Kaufman & Robinson, Inc., 1330 Blue Spruce Drive, Fort Collins, Colorado 80524 (United States); Zhou, Lin [College of Mechatronics and Automation, National University of Defense Technology, 109 Deya Road, Changsha, Hunan 410073 (China); Hu’nan Key Laboratory of Ultra-precision Machining Technology, Changsha, Hunan 410073 (China)

    2015-10-15

    We report on the development of a one-dimensional Ion Beam Figuring (IBF) system for x-ray mirror polishing. Ion beam figuring provides a highly deterministic method for the final precision figuring of optical components with advantages over conventional methods. The system is based on a state of the art sputtering deposition system outfitted with a gridded radio frequency inductive coupled plasma ion beam source equipped with ion optics and dedicated slit developed specifically for this application. The production of an IBF system able to produce an elongated removal function rather than circular is presented in this paper, where we describe in detail the technical aspect and present the first obtained results.

  7. X-ray spectrometer spectrograph telescope system. [for solar corona study

    Science.gov (United States)

    Bruner, E. C., Jr.; Acton, L. W.; Brown, W. A.; Salat, S. W.; Franks, A.; Schmidtke, G.; Schweizer, W.; Speer, R. J.

    1979-01-01

    A new sounding rocket payload that has been developed for X-ray spectroscopic studies of the solar corona is described. The instrument incorporates a grazing incidence Rowland mounted grating spectrograph and an extreme off-axis paraboloic sector feed system to isolate regions of the sun of order 1 x 10 arc seconds in size. The focal surface of the spectrograph is shared by photographic and photoelectric detection systems, with the latter serving as a part of the rocket pointing system control loop. Fabrication and alignment of the optical system is based on high precision machining and mechanical metrology techniques. The spectrograph has a resolution of 16 milliangstroms and modifications planned for future flights will improve the resolution to 5 milliangstroms, permitting line widths to be measured.

  8. Non-destructive test for VHTR fuel using 160kV X-ray system in Hotcell

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jun; Yoo, Boung Ok; Choo, Yong sun; Baik Sang youl; Kim, Hee Moon; Ahn, Sang Bok [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The research for VHTR which is one of the next generation reactor has been actively carried out. As a part of the research for VHTR, an irradiation examination for the VHTR fuel was performed to confirm an in-pile behavior in HANARO. The non-destructive test for the irradiated fuel is very important to understand the in-pile behavior of the fuel. Especially, the X-ray system is useful to observe the fuel shape without destruction. A dimensional change and defect of the fuel can be confirmed thorough the Xray system. Also, using the 3-D software and CT technology, the fuel shape can be intuitionally observed. The 450kV and 160kV X-ray system were installed and operated in IMEF hotcell. The 160kV X-ray system relatively using a low voltage is suitable to a small scale sample. And high resolution images can be obtained. In this study, the non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. Through these test, the possibility for the X-ray inspection of irradiated fuel was confirmed. The non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. The clear images of the irradiated coated particle were produced without the radiation damage during the Xray inspection. The X-ray images of the VHTR fuel will be utilized as the in-pile performance validation data.

  9. Non-destructive test for VHTR fuel using 160kV X-ray system in Hotcell

    International Nuclear Information System (INIS)

    Kim, Young Jun; Yoo, Boung Ok; Choo, Yong sun; Baik Sang youl; Kim, Hee Moon; Ahn, Sang Bok

    2016-01-01

    The research for VHTR which is one of the next generation reactor has been actively carried out. As a part of the research for VHTR, an irradiation examination for the VHTR fuel was performed to confirm an in-pile behavior in HANARO. The non-destructive test for the irradiated fuel is very important to understand the in-pile behavior of the fuel. Especially, the X-ray system is useful to observe the fuel shape without destruction. A dimensional change and defect of the fuel can be confirmed thorough the Xray system. Also, using the 3-D software and CT technology, the fuel shape can be intuitionally observed. The 450kV and 160kV X-ray system were installed and operated in IMEF hotcell. The 160kV X-ray system relatively using a low voltage is suitable to a small scale sample. And high resolution images can be obtained. In this study, the non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. Through these test, the possibility for the X-ray inspection of irradiated fuel was confirmed. The non-destructive test for the unirradiated and irradiated VHTR fuel were performed using the 160kV X-ray system. The clear images of the irradiated coated particle were produced without the radiation damage during the Xray inspection. The X-ray images of the VHTR fuel will be utilized as the in-pile performance validation data.

  10. Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

    International Nuclear Information System (INIS)

    Speidel, Michael A.; Tomkowiak, Michael T.; Raval, Amish N.; Van Lysel, Michael S.

    2010-01-01

    Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm 2 mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0±0.8 mm (mean ±one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error (±0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The

  11. An active interlock system for the NSLS x-ray ring insertion devices

    International Nuclear Information System (INIS)

    Nawrocky, R.J.; Biscardi, R.; Dabrowski, J.; Flannigan, J.; Ramamoorthy, S.; Rothman, J.; Smith, J.; So, I.; Thomas, M.; Decker, G.

    1991-01-01

    This paper describes the design and operation of an active interlock system which has been installed in the NSLS X-ray electron storage ing to protect the vacuum chamber from thermal damage by mis-steered high power photon beams from insertion devices (IDs). the system employs active beam position detectors to monitor beam motion in the ID straight sections and solid state logic circuitry to ''dump'' the stored beam in the event of a fault condition by interrupting the rf. To ensure a high degree of reliability, redundancy and continuous automatic checking has been incorporated into the design. Overall system integrity is checked periodically with beam at safe levels of beam current. 2 refs., 3 figs

  12. An alternative approach to contrast-detail testing of X-ray image intensifier systems

    International Nuclear Information System (INIS)

    Kotre, C.J.; Marshall, N.W.; Faulkner, K.

    1992-01-01

    The difficulties of making the results of threshold contrast-detail diameter tests on X-ray image intensifier systems consistent with published performance standards are discussed. The current approach to contrast-detail testing is described and an alternative method intended to give greater consistency for all image intensifier input field diameters proposed. The current and alternative test conditions are compared on two image intensifier systems. The results obtained show that the contrast-detail curves for image intensifier systems with a wide range of input field diameters can be effectively normalized to be directly comparable to a common reference standard by applying the proposed alternative test conditions. The implications of this result on the interpretation of the contrast-detail test are discussed. (author)

  13. Technology development of the soft X-ray tomography system in Wendelstein 7-X stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Schülke, M., E-mail: mathias.schuelke@ipp.mpg.de [Max Planck Institute for Plasma Physics, EURATOM Association, Wendelsteinstr. 1, 17491 Greifswald (Germany); Cardella, A.; Hathiramani, D.; Mettchen, S.; Thomsen, H.; Weißflog, S.; Zacharias, D. [Max Planck Institute for Plasma Physics, EURATOM Association, Wendelsteinstr. 1, 17491 Greifswald (Germany)

    2013-10-15

    Highlights: ► Engineering and design of soft X-ray Multi Camera Tomography System. ► Requirements of in-vessel diagnostics in Wendelstein 7-X. ► Development of internal cooling system including FEM-Analysis. ► Development of lateral shield system with testing for microwave stray radiation compatibility. ► Development of multipin feedthrough including welding qualification and leak tests. -- Abstract: The engineering and design of the soft X-ray Multi Camera Tomography System (XMCTS) in Wendelstein 7-X stellarator (W7-X) must fulfill several additional requirements compared to short pulse machines. The XMCTS has to withstand irradiation and electron cyclotron microwave loads in addition to being ultra high vacuum compatible, having low magnetic permeability and using low neutron activation materials (e.g. Co ≤ 2000 ppm). A further difficulty is the limited space inside the plasma vessel, which requires special engineering solutions. After detailed design development, supported by finite element analyses, prototypes have been manufactured and tested. At the end all test results have successfully proven that the components fulfill the requirements and that reliable and stable measurements will be possible with the XMCTS diagnostics during W7-X operation. The paper describes the design and the technological development, in particular on the electric multipin feedthrough (UHV barrier between in vessel detectors and the preamplifiers), the active cooling of the electronic components (reducing dark current/noise increase), the pneumatic shutter (protection of the detectors from sputtering and during baking) and the fiber optics illumination system (calibration of the detectors)

  14. Introduction of a deformable x-ray CT polymer gel dosimetry system

    Science.gov (United States)

    Maynard, E.; Heath, E.; Hilts, M.; Jirasek, A.

    2018-04-01

    This study introduces the first 3D deformable dosimetry system based on x-ray computed tomography (CT) polymer gel dosimetry and establishes the setup reproducibility, deformation characteristics and dose response of the system. A N-isopropylacrylamide (NIPAM)-based gel formulation optimized for x-ray CT gel dosimetry was used, with a latex balloon serving as the deformable container and low-density polyethylene and polyvinyl alcohol providing additional oxygen barrier. Deformable gels were irradiated with a 6 MV calibration pattern to determine dosimetric response and a dosimetrically uniform plan to determine the spatial uniformity of the response. Wax beads were added to each gel as fiducial markers to track the deformation and setup of the gel dosimeters. From positions of the beads on CT images the setup reproducibility and the limits and reproducibility of gel deformation were determined. Comparison of gel measurements with Monte Carlo dose calculations found excellent dosimetric accuracy, comparable to that of an established non-deformable dosimetry system, with a mean dose discrepancy of 1.5% in the low-dose gradient region and a gamma pass rate of 97.9% using a 3%/3 mm criterion. The deformable dosimeter also showed good overall spatial dose uniformity throughout the dosimeter with some discrepancies within 20 mm of the edge of the container. Tracking of the beads within the dosimeter found that sub-millimetre setup accuracy is achievable with this system. The dosimeter was able to deform and relax when externally compressed by up to 30 mm without sustaining any permanent damage. Internal deformations in 3D produced average marker movements of up to 12 mm along the direction of compression. These deformations were also shown to be reproducible over 100 consecutive deformations. This work has established several important characteristics of a new deformable dosimetry system which shows promise for future clinical applications, including the

  15. Radioisotopic-excited x-ray fluorescent system for PPM measurement of toxic heavy metals

    International Nuclear Information System (INIS)

    Leddicotte, G.W.; Tolea, F.; Hansen, J.S.

    1974-01-01

    In agricultural research there is a continual awareness of the need to determine the role trace elements have as micronutrients in soil-plant systems. Similarly, these agronomic needs have a strong relationship to the concern other life sciences researchers have about the roles and effects of toxic trace elements on the natural environment and the physiological well-being of man and animals. However, in order for these interest areas to carry out more effective study efforts, more practical and precise analytical methodology and devices need to be developed. This report describes a research effort to develop an analytical system for micronutient as well as toxic elements based on x-ray fluorescence

  16. X-ray fluorescence system for thin film composition analysis during deposition

    International Nuclear Information System (INIS)

    Formica, Sarah P.; Lee, Susanne M.

    2005-01-01

    A fast-response-time X-ray fluorescence (XRF) system was designed with a monolithic polycapillary focusing optic for in situ composition profiling during materials deposition. The polycapillary optic produced 10 5 times more intensity at the sample than a pinhole, allowing the detector placement to be outside most deposition chambers. The resultant XRF signals were so strong that measurement times were comparable to monolayer growth times. XRF line scans from Ge 1-x Sn x thin films were used to map Sn concentration versus surface position with a 10 μm resolution. The extrapolated instrumental detection limit using a 20 W Cu source was 10 12 atoms (ng). XRF from a 100-nm ion-implanted Ge 0.72 Sn 0.28 sample demonstrated the system's ability to monitor initial growth stages during deposition

  17. Early experience with a picture archiving and communication system for X-ray CT

    International Nuclear Information System (INIS)

    Nakano, Y.; Komori, M.; Minato, K.

    1987-01-01

    A network using fiberoptic ring architecture has been implemented to connect an x-ray CT unit with an image work station and optical disk storage unit. The work station has three noninterlaced cathode-ray tube (CRT) monitors of 1,024 X 1,024 pixels. The optical disk system stores 32 optical disk cartridges (2.6 Gbytes per cartridge). A general-purpose interface bus is used for communication between the CT unit and the network interface unit. Transfer time from CT to interface unit is 40 kbyte/second, 5 seconds per image. On-line data acquisition, long-term archiving, and CT interpretation using CRTs have been tested and the system has been working for 3 months in a clinical environment

  18. The x-ray light valve: A potentially low-cost, digital radiographic imaging system-concept and implementation considerations

    International Nuclear Information System (INIS)

    Webster, Christie Ann; Koprinarov, Ivaylo; Germann, Stephen; Rowlands, J. A.

    2008-01-01

    New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applications in radiology. A novel potentially low-cost radiographic imaging system based on established technologies is proposed--the X-Ray Light Valve (XLV). This is a potentially high-quality digital x-ray detector made of a photoconducting layer and a liquid-crystal cell, physically coupled in a sandwich structure. Upon exposure to x rays, charge is collected on the surface of the photoconductor. This causes a change in the optical properties of the liquid-crystal cell and a visible image is generated. Subsequently, it is digitized by a scanned optical imager. The image formation is based on controlled modulation of light from an external source. The operation and practical implementation of the XLV system are described. The potential performance of the complete system and issues related to sensitivity, spatial resolution, noise, and speed are discussed. The feasibility of clinical use of an XLV device based on amorphous selenium (a-Se) as the photoconductor and a reflective electrically controlled birefringence cell is analyzed. The results of our analysis indicate that the XLV can potentially be adapted to a wide variety of radiographic tasks

  19. The First Simultaneous X-Ray/Radio Detection of the First Be/BH System MWC 656

    Energy Technology Data Exchange (ETDEWEB)

    Ribó, M.; Paredes, J. M.; Marcote, B.; Moldón, J.; Paredes-Fortuny, X. [Departament de Física Quàntica i Astrofísica, Institut de Ciències del Cosmos (ICCUB), Universitat de Barcelona, IEEC-UB, Martí i Franquès 1, E08028 Barcelona (Spain); Munar-Adrover, P. [INAF/IAPS-Roma, I-00133 Roma (Italy); Iwasawa, K. [ICREA, Institut de Ciències del Cosmos (ICCUB), Universitat de Barcelona, IEEC-UB, Martí i Franquès 1, E-08028 Barcelona (Spain); Casares, J. [Instituto de Astrofísica de Canarias, E-38200 La Laguna, Tenerife (Spain); Migliari, S. [European Space Astronomy Centre, Apartado/P.O. Box 78, Villanueva de la Canada, E-28691 Madrid (Spain)

    2017-02-01

    MWC 656 is the first known Be/black hole (BH) binary system. Be/BH binaries are important in the context of binary system evolution and sources of detectable gravitational waves because they are possible precursors of coalescing neutron star/BH binaries. X-ray observations conducted in 2013 revealed that MWC 656 is a quiescent high-mass X-ray binary (HMXB), opening the possibility to explore X-ray/radio correlations and the accretion/ejection coupling down to low luminosities for BH HMXBs. Here we report on a deep joint Chandra /VLA observation of MWC 656 (and contemporaneous optical data) conducted in 2015 July that has allowed us to unambiguously identify the X-ray counterpart of the source. The X-ray spectrum can be fitted with a power law with Γ ∼ 2, providing a flux of ≃4 × 10{sup −15} erg cm{sup −2} s{sup −1} in the 0.5–8 keV energy range and a luminosity of L {sub X} ≃ 3 × 10{sup 30} erg s{sup −1} at a 2.6 kpc distance. For a 5 M{sub ⊙} BH this translates into ≃5 × 10{sup −9} L {sub Edd}. These results imply that MWC 656 is about 7 times fainter in X-rays than it was two years before and reaches the faintest X-ray luminosities ever detected in stellar-mass BHs. The radio data provide a detection with a peak flux density of 3.5 ± 1.1 μ Jy beam{sup −1}. The obtained X-ray/radio luminosities for this quiescent BH HMXB are fully compatible with those of the X-ray/radio correlations derived from quiescent BH low-mass X-ray binaries. These results show that the accretion/ejection coupling in stellar-mass BHs is independent of the nature of the donor star.

  20. In-situ X-ray diffraction system using sources and detectors at fixed angular positions

    Science.gov (United States)

    Gibson, David M [Voorheesville, NY; Gibson, Walter M [Voorheesville, NY; Huang, Huapeng [Latham, NY

    2007-06-26

    An x-ray diffraction technique for measuring a known characteristic of a sample of a material in an in-situ state. The technique includes using an x-ray source for emitting substantially divergent x-ray radiation--with a collimating optic disposed with respect to the fixed source for producing a substantially parallel beam of x-ray radiation by receiving and redirecting the divergent paths of the divergent x-ray radiation. A first x-ray detector collects radiation diffracted from the sample; wherein the source and detector are fixed, during operation thereof, in position relative to each other and in at least one dimension relative to the sample according to a-priori knowledge about the known characteristic of the sample. A second x-ray detector may be fixed relative to the first x-ray detector according to the a-priori knowledge about the known characteristic of the sample, especially in a phase monitoring embodiment of the present invention.

  1. X-ray studies on electrochemical systems. Synchrotron methods for energy materials

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Artur [Empa. Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland)

    2017-07-01

    This book is your graduate level entrance into battery, fuel cell and solar cell research at synchrotron X-ray sources. Materials scientists find numerous examples for the combination of electrochemical experiments with simple and with highly complex X-ray scattering and spectroscopy methods. Physicists and chemists can link applied electrochemistry with fundamental concepts of condensed matter physics, physical chemistry and surface science.

  2. A 500-MHz x-ray counting system with a silicon avalanche photodiode

    International Nuclear Information System (INIS)

    Kishimoto, Shunji

    2009-01-01

    In the present measurements using a Si-APD X-ray detector and a 500-MHz counting system, the maximum output rate of 3.3x10 8 s -1 was achieved for 8-keV X-rays in beamline BL-14A of the Photon Factory. A small Si-APD of 4-pF electric capacity was used as the detector device in order to output a pulse of a width shorter than 2 ns on the baseline. For processing the fast pulses, the discriminator and the scaler having a throughput of >500 MHz, were prepared. Since the acceleration frequency at the PF ring was 500.1 MHz and the empty-bunch spacing was 12/312 bunches per circumference, the expected maximum rate was 4.8x10 8s-1 according to the counting model for a pulsed photon source. The reason why the present system did not reach the expected value was the baseline shift at the amplifier outputs. The rise of +0.2 V was observed at a discriminator output of 3.3x10 8 s -1 , while the pulse height was lower than 0.2 V. The baseline shift was caused by an AC coupling circuit in the amplifier. If a DC coupling circuit can be used for the amplifier, instead of the AC coupling circuit, or an active adjustment to compensate the baseline shift is installed, the counting system will show an ideal response. Although the present system including NIM modules was not so compact, we would like to develop a new fast-counting circuit for a Si-APD array detector of more than 100 channels of small pixels, in near future. (author)

  3. A CMOS active pixel sensor system for laboratory- based x-ray diffraction studies of biological tissue

    International Nuclear Information System (INIS)

    Bohndiek, Sarah E; Cook, Emily J; Arvanitis, Costas D; Olivo, Alessandro; Royle, Gary J; Clark, Andy T; Prydderch, Mark L; Turchetta, Renato; Speller, Robert D

    2008-01-01

    X-ray diffraction studies give material-specific information about biological tissue. Ideally, a large area, low noise, wide dynamic range digital x-ray detector is required for laboratory-based x-ray diffraction studies. The goal of this work is to introduce a novel imaging technology, the CMOS active pixel sensor (APS) that has the potential to fulfil all these requirements, and demonstrate its feasibility for coherent scatter imaging. A prototype CMOS APS has been included in an x-ray diffraction demonstration system. An industrial x-ray source with appropriate beam filtration is used to perform angle dispersive x-ray diffraction (ADXRD). Optimization of the experimental set-up is detailed including collimator options and detector operating parameters. Scatter signatures are measured for 11 different materials, covering three medical applications: breast cancer diagnosis, kidney stone identification and bone mineral density calculations. Scatter signatures are also recorded for three mixed samples of known composition. Results are verified using two independent models for predicting the APS scatter signature: (1) a linear systems model of the APS and (2) a linear superposition integral combining known monochromatic scatter signatures with the input polychromatic spectrum used in this case. Cross validation of experimental, modelled and literature results proves that APS are able to record biologically relevant scatter signatures. Coherent scatter signatures are sensitive to multiple materials present in a sample and provide a means to quantify composition. In the future, production of a bespoke APS imager for x-ray diffraction studies could enable simultaneous collection of the transmitted beam and scattered radiation in a laboratory-based coherent scatter system, making clinical transfer of the technique attainable

  4. Repair of X-ray-induced single-strand breaks by a cell-free system

    International Nuclear Information System (INIS)

    Seki, Shuji; Ikeda, Shogo; Tsutui, Ken; Teraoka, Hirobumi

    1990-01-01

    Repair of X-ray-induced single-strand breaks of DNA was studied in vitro using an exonuclease purified from mouse ascites sarcoma (SR-C3H/He) cells. X-ray-dose-dependent unscheduled DNA synthesis was primed by the exonuclease. Repair of X-ray-induced single-strand breaks in pUC19 plasmid DNA was demonstrated by agarose gel electrophoresis after incubating the damaged DNA with the exonuclease, DNA polymerase (Klenow fragment of DNA polymerase I or DNA polymerase β purified from SR-C3H/He cells), four deoxynucleoside triphosphates, ATP and DNA ligase (T4 DNA ligase or DNA ligase I purified from calf thymus). The present results suggested that the exonuclease is involved in the initiation of repair of X-ray-induced single-strand breaks in removing 3' ends of X-ray-damaged DNA. (author)

  5. Fine Output Voltage Control Method considering Time-Delay of Digital Inverter System for X-ray Computed Tomography

    Science.gov (United States)

    Shibata, Junji; Kaneko, Kazuhide; Ohishi, Kiyoshi; Ando, Itaru; Ogawa, Mina; Takano, Hiroshi

    This paper proposes a new output voltage control for an inverter system, which has time-delay and nonlinear load. In the next generation X-ray computed tomography of a medical device (X-ray CT) that uses the contactless power transfer method, the feedback signal often contains time-delay due to AD/DA conversion and error detection/correction time. When the PID controller of the inverter system is received the adverse effects of the time-delay, the controller often has an overshoot and a oscillated response. In order to overcome this problem, this paper proposes a compensation method based on the Smith predictor for an inverter system having a time-delay and the nonlinear loads which are the diode bridge rectifier and X-ray tube. The proposed compensation method consists of the hybrid Smith predictor system based on an equivalent analog circuit and DSP. The experimental results confirm the validity of the proposed system.

  6. Statistics associated with an elemental analysis system of particles induced by X-ray emission

    International Nuclear Information System (INIS)

    Romo K, C.M.

    1987-01-01

    In the quantitative elemental analysis by X-ray techniques one has to use data spectra which present fluctuations of statistical nature both from the energy and from the number of counts accumulated. While processing the results for the obtainment of a quantitative result, a detailed knowledge of the associated statistics distributions is needed. In this work, l) the statistics associated with the system photon's counting as well as 2) the distribution of the results as a function of the energy are analyzed. The first one is important for the definition of the expected values and uncertainties and for the spectra simulation (Mukoyama, 1975). The second one is fundamental for the determination of the contribution for each spectral line. (M.R.) [es

  7. Calibration-free device sizing using an inverse geometry x-ray system

    International Nuclear Information System (INIS)

    Tomkowiak, Michael T.; Speidel, Michael A.; Raval, Amish N.; Van Lysel, Michael S.

    2011-01-01

    Purpose: Quantitative coronary angiography (QCA) can be used to support device size selection for cardiovascular interventions. The accuracy of QCA measurements using conventional x-ray fluoroscopy depends on proper calibration using a reference object and avoiding vessel foreshortening. The authors have developed a novel interventional device sizing method using the inverse geometry scanning-beam digital x-ray (SBDX) fluoroscopy system. The proposed method can measure the diameter and length of vessel segments without imaging a reference object and when vessels appear foreshortened. Methods: SBDX creates multiple tomosynthetic x-ray images corresponding to planes through the patient volume. The structures that lie in the plane are in focus and the features above and below the plane are blurred. Three-dimensional localization of the vessel edges was performed by examining the degree of blurring at each image plane. A 3D vessel centerline was created and used to determine vessel magnification and angulation relative to the image planes. Diameter measurements were performed using a model-based method and length measurements were calculated from the 3D centerline. Phantom validation was performed by measuring the diameter and length of vessel segments with nominal diameters ranging from 0.5 to 2.8 mm and nominal lengths of 42 mm. The phantoms were imaged at a range of positions between the source and the detector (±16 cm relative to isocenter) and with a range of foreshortening angles (0 deg. - 75 deg.). Results: Changes in vessel phantom position created magnifications ranging from 87% to 118% relative to isocenter magnification. Average diameter errors were less than 0.15 mm. Average length measurements were within 1% (0.3 mm) of the true length. No trends were observed between measurement accuracy and magnification. Changes in vessel phantom orientation resulted in decreased apparent length down to 28% of the original nonforeshortened length. Average diameter

  8. Non-destructive test for irradiated fuels using X-ray CT system in hot-laboratory

    International Nuclear Information System (INIS)

    Kim, Heemoon; Kim, Gil-Soo; Yoo, Boung-Ok; Tahk, Young-Wook; Cho, Moon-Sung; Ahn, Sang-Bok

    2015-01-01

    To inspect inside of irradiated fuel rod for PIE in hotcell, neutron beam and X-ray have been used. Many hot laboratories in the world have shown the results for NDT by 2-D film data. Currently, computed image processing technology instead of film has been developed and CT was applied to the X-ray and neutron beam system. In this trend, our facility needed to set up X-ray system for irradiated fuel inspection and installed in hotcell with consideration of radiation damage. In this study, X-ray system was tested to be operated with radioactive samples and was performed to inspect fuel rods and observe internal damage and dimensional change. 450kV X-ray CT system was installed in hotcell with modification and tested to check image resolution and radiation damage. The image data were analyzed by 3-D computer software. 8 fuel plates and VHTR rods were inspected and measured internal shape and dimension

  9. Application of in situ x-ray diffraction techniques in heterogenous catalytic systems

    International Nuclear Information System (INIS)

    Sharifah Bee Abd Hamid

    2002-01-01

    A broad range of techniques is available today for the characterisation of catalysts and the investigation of catalyst reaction mechanisms. However, only a limited number of those are suitable for in situ studies, i.e experiments performed in conditions mimicking or close as possible to real operating conditions. Various commercially and in-house developed in situ X-Ray diffraction (XRD) cells have been used to obtain information on the phase and structure of materials at the initial formation stage, activation methodology, calcination, reduction and carburization. A major advantage of the in situ X-ray cells is that it allows direct observations on the decomposition of precursors leading to various phases in a controlled environment, i.e. controlled temperature and pressure under specified gases. The cells can be operated both at high temperatures and high pressures, equipped with Position Sensitive Detector (PSD), feature which was used to study phase transformation occurring during the activation of various solids. In MoO 3 , XRD results provide detailed information on the hydrogen insertion into its lattice, followed by carburization providing good understanding on the mechanism in the solid transformation leading to the metastable MoC 1 -x phase. For the Bi-SnO x systems, the environmental cell coupled with XRD and PSD allow the design of activation procedure to obtain the active Bi 2 Sn 2 O 7 . The in situ XRD technique reveals crucial information on the initial stage of oxides formations prior to condensation reaction shown in MCM-41 and titania systems. In this presentation, discussions on general achievements and problems relating to the use of in situ XRD techniques as well as of specific examples selected to illustrate the use and potential of in situ XRD are made. It is not intended to be a review of the art but a highlight of the challenges which the catalytic and material scientists face when entering the avenue. (Author)

  10. Micromanipulation and pick-up system for X-Ray diffraction characterization of micrometer-sized single particles

    International Nuclear Information System (INIS)

    Takeichi, Y; Inami, N; Saito, K; Otori, H; Sagayama, R; Kumai, R; Ono, K; Ueno, T

    2014-01-01

    We describe a micromanipulation and pick-up system for preparing a micrometer-sized single particle for X-ray diffraction characterization. Combining a microgripper based on microelectromechanical systems, piezo-motor-driven linear stages, and a gamepad, the system provides precise and intuitive handling of the object. Single-crystal X-ray diffraction measurements of Sm-Fe-N permanent magnet were performed using this system. We also describe a method to distinguish crystallographically homogeneous particles found in powder-form samples.

  11. The simulated spectrum of the OGRE X-ray EM-CCD camera system

    Science.gov (United States)

    Lewis, M.; Soman, M.; Holland, A.; Lumb, D.; Tutt, J.; McEntaffer, R.; Schultz, T.; Holland, K.

    2017-12-01

    The X-ray astronomical telescopes in use today, such as Chandra and XMM-Newton, use X-ray grating spectrometers to probe the high energy physics of the Universe. These instruments typically use reflective optics for focussing onto gratings that disperse incident X-rays across a detector, often a Charge-Coupled Device (CCD). The X-ray energy is determined from the position that it was detected on the CCD. Improved technology for the next generation of X-ray grating spectrometers has been developed and will be tested on a sounding rocket experiment known as the Off-plane Grating Rocket Experiment (OGRE). OGRE aims to capture the highest resolution soft X-ray spectrum of Capella, a well-known astronomical X-ray source, during an observation period lasting between 3 and 6 minutes whilst proving the performance and suitability of three key components. These three components consist of a telescope made from silicon mirrors, gold coated silicon X-ray diffraction gratings and a camera that comprises of four Electron-Multiplying (EM)-CCDs that will be arranged to observe the soft X-rays dispersed by the gratings. EM-CCDs have an architecture similar to standard CCDs, with the addition of an EM gain register where the electron signal is amplified so that the effective signal-to-noise ratio of the imager is improved. The devices also have incredibly favourable Quantum Efficiency values for detecting soft X-ray photons. On OGRE, this improved detector performance allows for easier identification of low energy X-rays and fast readouts due to the amplified signal charge making readout noise almost negligible. A simulation that applies the OGRE instrument performance to the Capella soft X-ray spectrum has been developed that allows the distribution of X-rays onto the EM-CCDs to be predicted. A proposed optical model is also discussed which would enable the missions minimum success criteria's photon count requirement to have a high chance of being met with the shortest possible

  12. Establishment of X-ray Measurement System for On-line Monitoring of Water Content in Powder

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, J. S. [Korea Institute of Industrial Technology, Cheonan (Korea, Republic of); Choi, Y. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Choi, B. J. [Idealsystem Co., Daegu (Korea, Republic of)

    2012-05-15

    On-line process monitoring is of critical importance in many industries, and therefore a variety of the state-of-the-art physical and chemical measurement techniques have been proposed. But, these techniques have their own pros and cons under the field process environments. Because the field process environments are very different from the well-organized chemical laboratories, many factors should be considered in order to optimize the process monitoring system. However, there have been few studies on the on-line measurement of water content in powder materials. For that reason, the X-ray measurement system based on the X-ray scattering technique, which was first proposed in 2011 as a new method for the determination of water content in powder, has been improved. in the present study, our original X-ray measurement system has been modified for more rapid, simple, and adequate for maximizing the field applicability of the on-line monitoring system

  13. Cutting-edge technologies for X-ray systems ensuring safety, security, and comfort of diagnosis and treatment

    International Nuclear Information System (INIS)

    Sato, Naotaka; Kuroki, Takahiro

    2015-01-01

    X-ray systems that convert X-rays passing through the human body Into images are widely used in various fields of diagnosis and treatment, due to their simplicity and immediacy. In recent years. Improvements in the image quality and usability of such systems as a result of technological innovations have contributed to more accurate diagnosis and treatment and shorter examination times. Toshiba Medical Systems Corporation has been continuously developing exposure management technologies that can precisely estimate doses of exposure as well as technologies to reduce exposure. We are also making efforts to reduce the burden on patients through the development of technologies to enhance the effectiveness of examinations. By applying these technologies to our various X-ray products, we are actively promoting the provision of medical systems offering safety, security, and comfort to both patients, and operators and other medical staff. (author)

  14. X-ray detector

    International Nuclear Information System (INIS)

    Houston, J.M.; Whetten, N.R.

    1981-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of xray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes

  15. Equipment, components and production of x-ray

    International Nuclear Information System (INIS)

    Idris Besar

    2004-01-01

    The contents of this chapter are follows - Equipment, Components and Production of x-Ray: x-ray system, generator, control panel. x-ray tube, cathode, anode, envelope, housing, collimator, other components, x-ray production, Bremsstrahlung x-ray, characteristic x-ray, heat production

  16. X-ray absorption spectroscopy in biological systems. Opportunities and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Bovenkamp, Gudrun Lisa

    2013-05-15

    X-ray absorption spectroscopy has become more important for applications in the material sciences, geology, environmental science and biology, specifically in the field of molecular biology. The scope of this thesis is to add more experimental evidence in order to show how applicable X-ray absorption near edge structure (XANES) is to biology. Two biological systems were investigated, at the molecular level, lead uptake in plants and the effect of silver on bacteria. This investigation also included an analysis of the sensitivity of Pb L{sub 3}- and Ag L{sub 3}-XANES spectra with regard to their chemical environment. It was shown that Pb L{sub 3}- and Ag L{sub 3}-XANES spectra are sensitive to an environment with at least differences in the second coordination shell. The non-destructive and element specific properties of XANES are the key advantages that were very important for this investigation. However, in both projects the adequate selection of reference compounds, which required in some cases a chemical synthesis, was the critical factor to determine the chemical speciation and, finally, possible uptake and storage mechanisms for plants and antibacterial mechanisms of silver. The chemical environment of Pb in roots and leaves of plants from four different plant families and a lichen from a former lead mining site in the Eifel mountains in Germany was determined using both solid compounds and aqueous solutions of different ionic strength, which simulate the plant environment. The results can be interpreted in such a way that lead is sorbed on the surface of cell walls. Silver bonding as reaction with Staphylococcus aureus, Listeria monocytogenes, and Escherichia coli bacteria was determined using inorganic silver compounds and synthesized silver amino acids. Silver binds to sulfur, amine and carboxyl groups in amino acids.

  17. X-ray absorption spectroscopy in biological systems. Opportunities and limitations

    International Nuclear Information System (INIS)

    Bovenkamp, Gudrun Lisa

    2013-05-01

    X-ray absorption spectroscopy has become more important for applications in the material sciences, geology, environmental science and biology, specifically in the field of molecular biology. The scope of this thesis is to add more experimental evidence in order to show how applicable X-ray absorption near edge structure (XANES) is to biology. Two biological systems were investigated, at the molecular level, lead uptake in plants and the effect of silver on bacteria. This investigation also included an analysis of the sensitivity of Pb L 3 - and Ag L 3 -XANES spectra with regard to their chemical environment. It was shown that Pb L 3 - and Ag L 3 -XANES spectra are sensitive to an environment with at least differences in the second coordination shell. The non-destructive and element specific properties of XANES are the key advantages that were very important for this investigation. However, in both projects the adequate selection of reference compounds, which required in some cases a chemical synthesis, was the critical factor to determine the chemical speciation and, finally, possible uptake and storage mechanisms for plants and antibacterial mechanisms of silver. The chemical environment of Pb in roots and leaves of plants from four different plant families and a lichen from a former lead mining site in the Eifel mountains in Germany was determined using both solid compounds and aqueous solutions of different ionic strength, which simulate the plant environment. The results can be interpreted in such a way that lead is sorbed on the surface of cell walls. Silver bonding as reaction with Staphylococcus aureus, Listeria monocytogenes, and Escherichia coli bacteria was determined using inorganic silver compounds and synthesized silver amino acids. Silver binds to sulfur, amine and carboxyl groups in amino acids.

  18. Development of a dosimetric system for dental X-ray equipment quality control

    International Nuclear Information System (INIS)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  19. High resolution X-ray fluorescence imaging for a microbeam radiation therapy treatment planning system

    Science.gov (United States)

    Chtcheprov, Pavel; Inscoe, Christina; Burk, Laurel; Ger, Rachel; Yuan, Hong; Lu, Jianping; Chang, Sha; Zhou, Otto

    2014-03-01

    Microbeam radiation therapy (MRT) uses an array of high-dose, narrow (~100 μm) beams separated by a fraction of a millimeter to treat various radio-resistant, deep-seated tumors. MRT has been shown to spare normal tissue up to 1000 Gy of entrance dose while still being highly tumoricidal. Current methods of tumor localization for our MRT treatments require MRI and X-ray imaging with subject motion and image registration that contribute to the measurement error. The purpose of this study is to develop a novel form of imaging to quickly and accurately assist in high resolution target positioning for MRT treatments using X-ray fluorescence (XRF). The key to this method is using the microbeam to both treat and image. High Z contrast media is injected into the phantom or blood pool of the subject prior to imaging. Using a collimated spectrum analyzer, the region of interest is scanned through the MRT beam and the fluorescence signal is recorded for each slice. The signal can be processed to show vascular differences in the tissue and isolate tumor regions. Using the radiation therapy source as the imaging source, repositioning and registration errors are eliminated. A phantom study showed that a spatial resolution of a fraction of microbeam width can be achieved by precision translation of the mouse stage. Preliminary results from an animal study showed accurate iodine profusion, confirmed by CT. The proposed image guidance method, using XRF to locate and ablate tumors, can be used as a fast and accurate MRT treatment planning system.

  20. Time-resolved X-ray spectroscopies of chemical systems: New perspectives

    Directory of Open Access Journals (Sweden)

    Majed Chergui

    2016-05-01

    Full Text Available The past 3–5 years have witnessed a dramatic increase in the number of time-resolved X-ray spectroscopic studies, mainly driven by novel technical and methodological developments. The latter include (i the high repetition rate optical pump/X-ray probe studies, which have greatly boosted the signal-to-noise ratio for picosecond (ps X-ray absorption spectroscopy studies, while enabling ps X-ray emission spectroscopy (XES at synchrotrons; (ii the X-ray free electron lasers (XFELs are a game changer and have allowed the first femtosecond (fs XES and resonant inelastic X-ray scattering experiments to be carried out; (iii XFELs are also opening the road to the development of non-linear X-ray methods. In this perspective, I will mainly focus on the most recent technical developments and briefly address some examples of scientific questions that have been addressed thanks to them. I will look at the novel opportunities in the horizon.

  1. X-ray absorption spectroscopy of diluted system by undulator photon source and multi-element solid-state detector

    CERN Document Server

    Tanida, H

    2001-01-01

    In order to measure the extended X-ray absorption fine structure (EXAFS) spectrum of an ultra-diluted system, an optics and detector control system for a synchrotron radiation beamline is developed. The undulator gap width is continuously tuned to obtain the maximum X-ray photon flux during the energy scan for the EXAFS measurement. A piezoelectric translator optimizes the parallelism of the double crystal in a monochromator at each measurement point to compensate for mechanical errors of the monochromator, resulting in a smooth and intense X-ray photon flux during the measurement. For a detection of a weak fluorescence signal from diluted samples, a 19-element solid-state detector and digital signal processor are used. A K-edge EXAFS spectrum of iron in a myoglobin aqueous solution with a concentration of 5.58 parts per million was obtained by this system.

  2. miniPixD : a compact sample analysis system which combines X-ray imaging and diffraction

    International Nuclear Information System (INIS)

    Moss, Robert; Crews, Chiaki; Speller, Robert; Wilson, Matthew

    2017-01-01

    This paper introduces miniPixD : a new, compact system that utilises transmission X-ray imaging and X-ray diffraction (XRD) to locate and identify materials of interest within an otherwise opaque volume. The system and the embodied techniques have utility in security screening, medical diagnostics, non-destructive testing (NDT) and quality assurance (QA). This paper outlines the design of the system including discussion on the choice of components and presents some data from relevant samples which are compared to other energy dispersive and angular dispersive XRD techniques.

  3. Quickness analysis and realization of DDC316 in low-energy X-rays detection acquisition system

    International Nuclear Information System (INIS)

    Gao Fuqiang; Zhang Yaqiong; Zhang Xiaojiao

    2011-01-01

    According to the performance requirements of Industry low-energy X-rays Detection acquisition sys- tem, through analyzing the characteristics of low-energy X-rays, DDC316 and series of other ADC chips, to research the impact on systems rapidity when using DDC316 chip to achieve signal amplifier and A/D conversion the detection system based on FPGA technique, choose series of Cyclone EPIC3T144C8 as the main control chip which produced by Altera company, in order to improve the rapidity of the system. (authors)

  4. Evaluation of an automated assay system to measure soil radionuclides by L x-ray and gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Nyhan, J.W.; Drennon, B.J.; Crowell, J.M.

    1982-08-01

    An automated radionuclide assay system for conducting soil radioassays using L x-ray and gamma-ray spectrometry was evaluated. Wet chemistry assay procedures were shown to be considerably more time consuming than similar analyses of soil on this radionuclide assay system. The detection limits of 241 Am and plutonium were determined, as well as the reproducibility of radionuclide assay results. The L x-ray spectrometric measurements were compared with radiochemical analyses on several tuff samples. The assay system's intrinsic germanium detector was found to respond linearly to varying low concentrations of 241 Am and plutonium, both of which were easily detected in the presence of elevated concentrations of 137 Cs

  5. Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yidong, E-mail: yidongyang@med.miami.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 and Department of Radiation Oncology, University of Miami School of Medicine, Miami, Florida 33136 (United States); Wang, Ken Kang-Hsin; Wong, John W. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Eslami, Sohrab; Iordachita, Iulian I. [Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Patterson, Michael S. [Juravinski Cancer Centre and Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario L8S4K1 (Canada)

    2015-04-15

    .0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems.

  6. Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

    International Nuclear Information System (INIS)

    Yang, Yidong; Wang, Ken Kang-Hsin; Wong, John W.; Eslami, Sohrab; Iordachita, Iulian I.; Patterson, Michael S.

    2015-01-01

    .0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems

  7. Effect of antioxidants on x-ray induced DNA SSB and DSB in different cell systems

    International Nuclear Information System (INIS)

    Ramadu, Kadem

    1998-01-01

    The effect of x-ray radiation or antioxidants such as actinomycin D, cycloheximide and mitomycin C is studied on CHO, BHK and HeLa cells. X-ray radiation caused DNA single strand breaks (SSB) and double strand breaks (DSB) are prevented by cycloheximide and actinomycin-D. The DSB and SSB are significant in the case of x-ray radiation in combination with MMC, but different with actinomycin-D and cycloheximide in combination with x-ray radiation which causes less number of SSB and DSB. The ISC is observed more with x-ray radiation in combination with antioxidants mitomycin C (MMC) than that of cycloheximide and actinomycin-D, which individually causes inhibition of ISC induced by x-ray radiation. This observation proves that the MMC has an additive effect on x-ray induced ISC during cell proliferation. During cell proliferation, cell viability is observed with x-ray radiation and antioxidants which are dependent on the cell cycle phase. However, in the control cells, the initial Go-phase has shown negligible difference in percent cell viability thereby during S-phase gradual increase in the cell viability, and cell proliferation have been found to be stopped at G2+M-phase. On the contrary, cell viability and the extent of cell proliferation with x-ray radiation in combination with MMC have shown more damage (OH-damage) than is caused by x-ray radiation and MMC, separately. But, the fact is that actinomycin-D and cycloheximide act as antioxidants preventing thereby free radical formation and cell death, caused by x-ray radiation. During cell proliferation, cells observed from S and (G2+M) phase exhibit difference in cell viability in all the treatments alone and in combination. HeLa cells have been found insensitive to x-ray radiation and could be ascribed to the presence of glutathione transferase, which is less in CHO/BHK cell line. (author)

  8. Characterizing X-ray detectors for prototype digital breast tomosynthesis systems

    International Nuclear Information System (INIS)

    Kim, Y.-S.; Park, H.-S.; Park, S.-J.; Choi, S.; Lee, H.; Kim, H.-J.; Lee, D.; Choi, Y.-W.

    2016-01-01

    The digital breast tomosynthesis (DBT) system is a newly developed 3-D imaging technique that overcomes the tissue superposition problems of conventional mammography. Therefore, it produces fewer false positives. In DBT system, several parameters are involved in image acquisition, including geometric components. A series of projections should be acquired at low exposure. This makes the system strongly dependent on the detector's characteristic performance. This study compares two types of x-ray detectors developed by the Korea Electrotechnology Research Institute (KERI). The first prototype DBT system has a CsI (Tl) scintillator/CMOS based flat panel digital detector (2923 MAM, Dexela Ltd.), with a pixel size of 0.0748 mm. The second uses a-Se based direct conversion full field detector (AXS 2430, analogic) with a pixel size of 0.085 mm. The geometry of both systems is same, with a focal spot 665.8 mm from the detector, and a center of rotation 33 mm above the detector surface. The systems were compared with regard to modulation transfer function (MTF), normalized noise power spectrum (NNPS), detective quantum efficiency (DQE) and a new metric, the relative object detectability (ROD). The ROD quantifies the relative performance of each detector at detecting specified objects. The system response function demonstrated excellent linearity (R 2 >0.99). The CMOS-based detector had a high sensitivity, while the Anrad detector had a large dynamic range. The higher MTF and noise power spectrum (NPS) values were measured using an Anrad detector. The maximum DQE value of the Dexela detector was higher than that of the Anrad detector with a low exposure level, considering one projection exposure for tomosynthesis. Overall, the Dexela detector performed better than did the Anrad detector with regard to the simulated Al wires, spheres, test objects of ROD with low exposure level. In this study, we compared the newly developed prototype DBT system with two different types

  9. X-RAY EMISSION FROM THE DOUBLE-BINARY OB-STAR SYSTEM QZ CAR (HD 93206)

    International Nuclear Information System (INIS)

    Parkin, E. R.; Naze, Y.; Rauw, G.; Broos, P. S.; Townsley, L. K.; Pittard, J. M.; Moffat, A. F. J.; Oskinova, L. M.; Waldron, W. L.

    2011-01-01

    X-ray observations of the double-binary OB-star system QZ Car (HD 93206) obtained with the Chandra X-ray Observatory over a period of roughly 2 years are presented. The respective orbits of systems A (O9.7 I+b2 v, P A = 21 days) and B (O8 III+o9 v, P B = 6 days) are reasonably well sampled by the observations, allowing the origin of the X-ray emission to be examined in detail. The X-ray spectra can be well fitted by an attenuated three-temperature thermal plasma model, characterized by cool, moderate, and hot plasma components at kT ≅ 0.2, 0.7, and 2 keV, respectively, and a circumstellar absorption of ≅0.2 x 10 22 cm -2 . Although the hot plasma component could be indicating the presence of wind-wind collision shocks in the system, the model fluxes calculated from spectral fits, with an average value of ≅7 x 10 -13 erg s -1 cm -2 , do not show a clear correlation with the orbits of the two constituent binaries. A semi-analytical model of QZ Car reveals that a stable momentum balance may not be established in either system A or B. Yet, despite this, system B is expected to produce an observed X-ray flux well in excess of the observations. If one considers the wind of the O8 III star to be disrupted by mass transfer, the model and observations are in far better agreement, which lends support to the previous suggestion of mass transfer in the O8 III + o9 v binary. We conclude that the X-ray emission from QZ Car can be reasonably well accounted for by a combination of contributions mainly from the single stars and the mutual wind-wind collision between systems A and B.

  10. Spectral filter for splitting a beam with electromagnetic radiation having wavelengths in the extreme ultraviolet (EUV) or soft X-Ray (Soft X) and the infrared (IR) wavelength range

    NARCIS (Netherlands)

    van Goor, F.A.; Bijkerk, Frederik; van den Boogaard, Toine; van den Boogaard, A.J.R.; van der Meer, R.

    2012-01-01

    Spectral filter for splitting the primary radiation from a generated beam with primary electromagnetic radiation having a wavelength in the extreme ultraviolet (EUV radiation) or soft X-ray (soft X) wavelength range and parasitic radiation having a wavelength in the infrared wavelength range (IR

  11. Bond Shortening (1.4 Å) in the Singlet and Triplet Excited States of [Ir2(dimen)4]2+ in Solution Determined by Time-Resolved X-ray Scattering

    DEFF Research Database (Denmark)

    Haldrup, Martin Kristoffer; Harlang, Tobias; Christensen, Morten

    2011-01-01

    Ground- and excited-state structures of the bimetallic, ligand-bridged compound Ir2(dimen)42+ are investigated in acetonitrile by means of time-resolved X-ray scattering. Following excitation by 2 ps laser pulses at 390 nm, analysis of difference scattering patterns obtained at eight different ti...

  12. Design of the data management system for hard X-ray modulation telescope based on real-time Linux

    International Nuclear Information System (INIS)

    Jia Tao; Zhang Zhi

    2004-01-01

    Hard X-ray Modulation Telescope is an electronic subsystem, the data management system for capturing the data of the telescope, then managing and transferring them. The data management system also deals with the communication with the satellite. Because of these functions, it needs highly steady quality and good real-time performance. This paper describes the design of the system. (authors)

  13. Study on Construction of a Medical X-Ray Direct Digital Radiography System and Hybrid Preprocessing Methods

    Directory of Open Access Journals (Sweden)

    Yong Ren

    2014-01-01

    Full Text Available We construct a medical X-ray direct digital radiography (DDR system based on a CCD (charge-coupled devices camera. For the original images captured from X-ray exposure, computer first executes image flat-field correction and image gamma correction, and then carries out image contrast enhancement. A hybrid image contrast enhancement algorithm which is based on sharp frequency localization-contourlet transform (SFL-CT and contrast limited adaptive histogram equalization (CLAHE, is proposed and verified by the clinical DDR images. Experimental results show that, for the medical X-ray DDR images, the proposed comprehensive preprocessing algorithm can not only greatly enhance the contrast and detail information, but also improve the resolution capability of DDR system.

  14. Development of an X-ray Computed Tomography System for Non-Invasive Imaging of Industrial Materials

    International Nuclear Information System (INIS)

    Abdullah, J.; Sipaun, S. M.; Mustapha, I.; Zain, R. M.; Rahman, M. F. A.; Mustapha, M.; Shaari, M. R.; Hassan, H.; Said, M. K. M.; Mohamad, G. H. P.; Ibrahim, M. M.

    2008-01-01

    X-ray computed tomography is a powerful non-invasive imaging technique for viewing an object's inner structures in two-dimensional cross-section images without the need to physically section it. The invention of CT techniques revolutionised the field of medical diagnostic imaging because it provided more detailed and useful information than any previous non-invasive imaging techniques. The method is increasingly being used in industry, aerospace, geosciences and archaeology. This paper describes the development of an X-ray computed tomography system for imaging of industrial materials. The theoretical aspects of CT scanner, the system configurations and the adopted algorithm for image reconstruction are discussed. The penetrating rays from a 160 kV industrial X-ray machine were used to investigate structures that manifest in a manufactured component or product. Some results were presented in this paper

  15. Development of an alternating magnetic-field-assisted finishing process for microelectromechanical systems micropore x-ray optics

    International Nuclear Information System (INIS)

    Riveros, Raul E.; Yamaguchi, Hitomi; Mitsuishi, Ikuyuki; Takagi, Utako; Ezoe, Yuichiro; Kato, Fumiki; Sugiyama, Susumu; Yamasaki, Noriko; Mitsuda, Kazuhisa

    2010-01-01

    X-ray astronomy research is often limited by the size, weight, complexity, and cost of functioning x-ray optics. Micropore optics promises an economical alternative to traditional (e.g., glass or foil) x-ray optics; however, many manufacturing difficulties prevent micropore optics from being a viable solution. Ezoe et al. introduced microelectromechanical systems (MEMS) micropore optics having curvilinear micropores in 2008. Made by either deep reactive ion etching or x-ray lithography, electroforming, and molding (LIGA), MEMS micropore optics suffer from high micropore sidewall roughness (10-30nmrms) which, by current standards, cannot be improved. In this research, a new alternating magnetic-field-assisted finishing process was developed using a mixture of ferrofluid and microscale abrasive slurry. A machine was built, and a set of working process parameters including alternating frequency, abrasive size, and polishing time was selected. A polishing experiment on a LIGA-fabricated MEMS micropore optic was performed, and a change in micropore sidewall roughness of 9.3±2.5nmrms to 5.7±0.7nmrms was measured. An improvement in x-ray reflectance was also seen. This research shows the feasibility and confirms the effects of this new polishing process on MEMS micropore optics.

  16. Development of an alternating magnetic-field-assisted finishing process for microelectromechanical systems micropore x-ray optics.

    Science.gov (United States)

    Riveros, Raul E; Yamaguchi, Hitomi; Mitsuishi, Ikuyuki; Takagi, Utako; Ezoe, Yuichiro; Kato, Fumiki; Sugiyama, Susumu; Yamasaki, Noriko; Mitsuda, Kazuhisa

    2010-06-20

    X-ray astronomy research is often limited by the size, weight, complexity, and cost of functioning x-ray optics. Micropore optics promises an economical alternative to traditional (e.g., glass or foil) x-ray optics; however, many manufacturing difficulties prevent micropore optics from being a viable solution. Ezoe et al. introduced microelectromechanical systems (MEMS) micropore optics having curvilinear micropores in 2008. Made by either deep reactive ion etching or x-ray lithography, electroforming, and molding (LIGA), MEMS micropore optics suffer from high micropore sidewall roughness (10-30nmrms) which, by current standards, cannot be improved. In this research, a new alternating magnetic-field-assisted finishing process was developed using a mixture of ferrofluid and microscale abrasive slurry. A machine was built, and a set of working process parameters including alternating frequency, abrasive size, and polishing time was selected. A polishing experiment on a LIGA-fabricated MEMS micropore optic was performed, and a change in micropore sidewall roughness of 9.3+/-2.5nmrms to 5.7+/-0.7nmrms was measured. An improvement in x-ray reflectance was also seen. This research shows the feasibility and confirms the effects of this new polishing process on MEMS micropore optics.

  17. Development of an alternating magnetic-field-assisted finishing process for microelectromechanical systems micropore x-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    Riveros, Raul E.; Yamaguchi, Hitomi; Mitsuishi, Ikuyuki; Takagi, Utako; Ezoe, Yuichiro; Kato, Fumiki; Sugiyama, Susumu; Yamasaki, Noriko; Mitsuda, Kazuhisa

    2010-06-20

    X-ray astronomy research is often limited by the size, weight, complexity, and cost of functioning x-ray optics. Micropore optics promises an economical alternative to traditional (e.g., glass or foil) x-ray optics; however, many manufacturing difficulties prevent micropore optics from being a viable solution. Ezoe et al. introduced microelectromechanical systems (MEMS) micropore optics having curvilinear micropores in 2008. Made by either deep reactive ion etching or x-ray lithography, electroforming, and molding (LIGA), MEMS micropore optics suffer from high micropore sidewall roughness (10-30nmrms) which, by current standards, cannot be improved. In this research, a new alternating magnetic-field-assisted finishing process was developed using a mixture of ferrofluid and microscale abrasive slurry. A machine was built, and a set of working process parameters including alternating frequency, abrasive size, and polishing time was selected. A polishing experiment on a LIGA-fabricated MEMS micropore optic was performed, and a change in micropore sidewall roughness of 9.3{+-}2.5nmrms to 5.7{+-}0.7nmrms was measured. An improvement in x-ray reflectance was also seen. This research shows the feasibility and confirms the effects of this new polishing process on MEMS micropore optics.

  18. A study on the digital image transfer application mass chest X-ray system up-grade

    International Nuclear Information System (INIS)

    Kim, Sun Chil; Park, Jong Sam; Lee, Jon Il

    2003-01-01

    By converting movable indirect mass chest X-ray devices for vehicles into digital systems and upgrading it to share information with the hospital's medical image information system, excellencies have been confirmed as a result of installing and running this type of system and are listed hereinafter. Upgrading analog systems, such as indirect mass chest X-ray devices dependent on printed film, to digital systems allows them to be run and managed much more efficiently, contributing to the increase in the stability and the efficiency of the system. Unlike existing images, communication based on DICOM standards allow images to be compatible with the hospital's outer and inner network PACS systems, extending the scope of the radiation departments information system. Assuming chest-exclusive indirect mass chest X-rays, a linked development of CAD (Computer Aided Diagnosis, Detector) becomes possible. By applying wireless Internet, Web-PACS for movable indirect mass chest X-ray devices for vehicles will become possible. Research in these fields must continue and if the superior image quality and convenience of digital systems are confirmed, I believe that the conversion of systems still dependent on analog images to modernized digital systems is a must

  19. Dual view x-ray inspection system for foreign objects detection in canned food

    Science.gov (United States)

    Lu, Zhiwen; Peng, Ningsong

    2013-04-01

    X-ray inspection technique for foreign objects in food products can determine and mark the presence of contaminants within the product by using image processing and pattern recognition technique on the X-ray transmission images. This paper presents the dual view X-ray inspection technique for foreign objects in food jar via analyzing the weak points of the traditional single view X-ray inspection technique. In addition, a prototype with the new technique is developed in accordance with glass splinters detection within the food jar (glass jar especially) which is a typical tickler. Some algorithms such as: adaptive image segmentation based on contour tracking, nonlinear arctan function transform and etc., are applied to improve image quality and achieve effective inspection results. The false recognition rate is effectively reduced and the detection sensitivity is highly enhanced. Finally the actual test results of this prototype are given.

  20. X-ray photoelectron spectroscopy of the uranium/oxygen system

    International Nuclear Information System (INIS)

    Allen, G.C.; Holmes, N.R.

    1986-10-01

    Other authors have presented evidence to show that the oxidised surface layer which forms on UO 2 at 25 0 C is amorphous UO 3 . In the present study X-ray photoelectron spectroscopy, infra-red spectroscopy and X-ray diffraction have been used to characterise the higher oxides α-UO 3 , β-UO 3 , γ-UO 3 and δ-UO 3 . While the infra-red and X-ray diffraction results may be used to characterise each oxide the X-ray photoelectron spectra for each phase are very similar. During reduction of the oxide surface in the spectrometer changes in the spectra were observed which were shown to be associated with particular oxidation states of the metal rather than different uranium atom coordination sites within the oxide. A close structural relationship is demonstrated between these oxides and the product at the surface of air-oxidised UO 2 fuel. (author)

  1. A Magnetron Sputter Deposition System for the Development of Multilayer X-Ray Optics

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposal objective is to establish the capability to deposit multilayer structures for X-ray, neutron, and EUV optic applications through the development of a...

  2. Defects of the central nervous system in Finland. IV. Associations with diagnostic x-ray examinations

    International Nuclear Information System (INIS)

    Granroth, G.

    1979-01-01

    Based on the Finnish Register of Congenital Malformations a search was undertaken to find possible associations between defects of the CNS and diagnostic x-ray examinations of the mother during pregnancy as well as pelvic x-ray examinations prior to pregnancy. Time-area-matched pregnancies and polydactylic children were used as controls. The risk of having a microcephalic child was increased for mothers with pelvic x-ray prior to pregnancy, but the number of discordant pairs was small. Of the examinations performed during pregnancy, fetal x-ray was significantly more common among mothers who delivered a CNS-defective child. No associations were observed for other kinds of examinations

  3. An optimal ross filter system for soft X-ray spectra measurement

    International Nuclear Information System (INIS)

    Huang Tianxuan; Zheng Zhijian; Sun Kexu; Jiang Shaoen

    2000-01-01

    A broadband Ross filter spectrometer is described for measuring soft X-ray radiation (0.1∼1.5 keV) emitted from laser plasma. It consists of a number of channels, each representing a Ross filter pair in conjunction with Al cathode X-ray diodes. An optimal channel has flat response within the sensitivity band, and minimal response outside it. The effect of some uncertainties on the accuracy of measurements is calculated

  4. High-resolution x-ray scattering studies of charge ordering in highly correlated electron systems

    International Nuclear Information System (INIS)

    Ghazi, M.E.

    2002-01-01

    Many important properties of transition metal oxides such as, copper oxide high-temperature superconductivity and colossal magnetoresistance (CMR) in manganites are due to strong electron-electron interactions, and hence these systems are called highly correlated systems. These materials are characterised by the coexistence of different kinds of order, including charge, orbital, and magnetic moment. This thesis contains high-resolution X-ray scattering studies of charge ordering in such systems namely the high-T C copper oxides isostructural system, La 2-x Sr x NiO 4 with various Sr concentrations (x = 0.33 - 0.2), and the CMR manganite system, Nd 1/2 Sr 1/2 MnO 3 . It also includes a review of charge ordering in a large variety of transition metal oxides, such as ferrates, vanadates, cobaltates, nickelates, manganites, and cuprates systems, which have been reported to date in the scientific literature. Using high-resolution synchrotron X-ray scattering, it has been demonstrated that the charge stripes exist in a series of single crystals of La 2-x Sr x NiO 4 with Sr concentrations (x = 0.33 - 0.2) at low temperatures. Satellite reflections due to the charge ordering were found with the wavevector (2ε, 0, 1) below the charge ordering transition temperature, T CO , where 2ε is the amount of separation from the corresponding Bragg peak. The charge stripes are shown to be two-dimensional in nature both by measurements of their correlation lengths and by measurement of the critical exponents of the charge stripe melting transition with an anomaly at x = 0.25. The results show by decreasing the hole concentration from the x = 0.33 to 0.2, the well-correlated charge stripes change to a glassy state at x = 0.25. The electronic transition into the charge stripe phase is second-order without any corresponding structural transition. Above the second-order transition critical scattering was observed due to fluctuations into the charge stripe phase. In a single-crystal of Nd

  5. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  6. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... talk with you about chest radiography also known as chest x-rays. Chest x-rays are the ... treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray ...

  8. A rotational and axial motion system load frame insert for in situ high energy x-ray studies

    Energy Technology Data Exchange (ETDEWEB)

    Shade, Paul A., E-mail: paul.shade.1@us.af.mil; Schuren, Jay C.; Turner, Todd J. [Materials and Manufacturing Directorate, Air Force Research Laboratory, Wright-Patterson AFB, Ohio 45433 (United States); Blank, Basil [PulseRay, Beaver Dams, New York 14812 (United States); Kenesei, Peter; Goetze, Kurt; Lienert, Ulrich; Almer, Jonathan [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Suter, Robert M. [Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Bernier, Joel V.; Li, Shiu Fai [Engineering Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Lind, Jonathan [Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Engineering Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2015-09-15

    High energy x-ray characterization methods hold great potential for gaining insight into the behavior of materials and providing comparison datasets for the validation and development of mesoscale modeling tools. A suite of techniques have been developed by the x-ray community for characterizing the 3D structure and micromechanical state of polycrystalline materials; however, combining these techniques with in situ mechanical testing under well characterized and controlled boundary conditions has been challenging due to experimental design requirements, which demand new high-precision hardware as well as access to high-energy x-ray beamlines. We describe the design and performance of a load frame insert with a rotational and axial motion system that has been developed to meet these requirements. An example dataset from a deforming titanium alloy demonstrates the new capability.

  9. Development of intelligent control system for X-ray streak camera in diagnostic instrument manipulator

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Tian, Jinshou [Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Fang, Yuman [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Gao, Guilong; Liang, Lingliang [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Wen, Wenlong [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China)

    2015-11-01

    An intelligent control system for an X ray streak camera in a diagnostic instrument manipulator (DIM) is proposed and implemented, which can control time delay, electric focusing, image gain adjustment, switch of sweep voltage, acquiring environment parameters etc. The system consists of 16 A/D converters and 16 D/A converters, a 32-channel general purpose input/output (GPIO) and two sensors. An isolated DC/DC converter with multi-outputs and a single mode fiber were adopted to reduce the interference generated by the common ground among the A/D, D/A and I/O. The software was designed using graphical programming language and can remotely access the corresponding instrument from a website. The entire intelligent control system can acquire the desirable data at a speed of 30 Mb/s and store it for later analysis. The intelligent system was implemented on a streak camera in a DIM and it shows a temporal resolution of 11.25 ps, spatial distortion of less than 10% and dynamic range of 279:1. The intelligent control system has been successfully used in a streak camera to verify the synchronization of multi-channel laser on the Inertial Confinement Fusion Facility.

  10. Optimisation of a propagation-based x-ray phase-contrast micro-CT system

    Science.gov (United States)

    Nesterets, Yakov I.; Gureyev, Timur E.; Dimmock, Matthew R.

    2018-03-01

    Micro-CT scanners find applications in many areas ranging from biomedical research to material sciences. In order to provide spatial resolution on a micron scale, these scanners are usually equipped with micro-focus, low-power x-ray sources and hence require long scanning times to produce high resolution 3D images of the object with acceptable contrast-to-noise. Propagation-based phase-contrast tomography (PB-PCT) has the potential to significantly improve the contrast-to-noise ratio (CNR) or, alternatively, reduce the image acquisition time while preserving the CNR and the spatial resolution. We propose a general approach for the optimisation of the PB-PCT imaging system. When applied to an imaging system with fixed parameters of the source and detector this approach requires optimisation of only two independent geometrical parameters of the imaging system, i.e. the source-to-object distance R 1 and geometrical magnification M, in order to produce the best spatial resolution and CNR. If, in addition to R 1 and M, the system parameter space also includes the source size and the anode potential this approach allows one to find a unique configuration of the imaging system that produces the required spatial resolution and the best CNR.

  11. Development of intelligent control system for X-ray streak camera in diagnostic instrument manipulator

    International Nuclear Information System (INIS)

    Pei, Chengquan; Wu, Shengli; Tian, Jinshou; Liu, Zhen; Fang, Yuman; Gao, Guilong; Liang, Lingliang; Wen, Wenlong

    2015-01-01

    An intelligent control system for an X ray streak camera in a diagnostic instrument manipulator (DIM) is proposed and implemented, which can control time delay, electric focusing, image gain adjustment, switch of sweep voltage, acquiring environment parameters etc. The system consists of 16 A/D converters and 16 D/A converters, a 32-channel general purpose input/output (GPIO) and two sensors. An isolated DC/DC converter with multi-outputs and a single mode fiber were adopted to reduce the interference generated by the common ground among the A/D, D/A and I/O. The software was designed using graphical programming language and can remotely access the corresponding instrument from a website. The entire intelligent control system can acquire the desirable data at a speed of 30 Mb/s and store it for later analysis. The intelligent system was implemented on a streak camera in a DIM and it shows a temporal resolution of 11.25 ps, spatial distortion of less than 10% and dynamic range of 279:1. The intelligent control system has been successfully used in a streak camera to verify the synchronization of multi-channel laser on the Inertial Confinement Fusion Facility

  12. Characterizing the X-ray Radiation Field in the Earth-like Planet Forming ExoSystem HD 113766

    Science.gov (United States)

    Lisse, Carey

    2010-09-01

    We propose a 100 ksec ACIS-S observation of the 12 Myr old system HD 113766, the site of on-going terrestrial planet formation (Lisse et al. 2008), in order to determine the spectrum of x-ray radiation in the fledgling system, its origin in the stellar coronae and proto-planetary disk, and its potential impact on the nascent planet.

  13. Pulsed X-Ray Emission from Pulsar A in the Double Pulsar System J0737-3039

    NARCIS (Netherlands)

    Chatterjee, S.; Gaensler, B.M.; Melatos, A.; Brisken, W.F.; Stappers, B.W.

    2007-01-01

    The double pulsar system J0737-3039 is not only a test bed for general relativity and theories of gravity, but also provides a unique laboratory for probing the relativistic winds of neutron stars. Recent X-ray observations have revealed a point source at the position of the J0737-3039 system, but

  14. A phase-contrast X-ray imaging system--with a 60x30 mm field of view--based on a skew-symmetric two-crystal X-ray interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Akio E-mail: a-yoneya@rd.hitachi.co.jp; Takeda, Tohoru; Tsuchiya, Yoshinori; Wu Jin; Lwin, T.-T.; Koizumi, Aritaka; Hyodo, Kazuyuki; Itai, Yuji

    2004-05-01

    A phase-contrast X-ray imaging system - with a 60x30 mm field of view - for biomedical observations was developed. To extend the observation field of view, the system is fitted with a skew-symmetric two-crystal X-ray interferometer. To attain the required sub-nanoradian mechanical stability between the crystal blocks for precise operation, the interferometer was mounted on two extremely rigid positioning tables (one with a sleeve bearings) and was controlled by a feedback positioning system using phase-lock interferometry. The imaging system produced a 60x30 mm interference pattern with 60% visibility using 17.7 keV monochromatic synchrotron X-rays at the Photon Factory. It was then used to perform radiographic observation (i.e., phase mapping) of rat liver vessels. These results indicate that this imaging system can be used to perform observations of large and in vivo biological samples.

  15. A phase-contrast X-ray imaging system--with a 60x30 mm field of view--based on a skew-symmetric two-crystal X-ray interferometer

    International Nuclear Information System (INIS)

    Yoneyama, Akio; Takeda, Tohoru; Tsuchiya, Yoshinori; Wu Jin; Lwin, T.-T.; Koizumi, Aritaka; Hyodo, Kazuyuki; Itai, Yuji

    2004-01-01

    A phase-contrast X-ray imaging system - with a 60x30 mm field of view - for biomedical observations was developed. To extend the observation field of view, the system is fitted with a skew-symmetric two-crystal X-ray interferometer. To attain the required sub-nanoradian mechanical stability between the crystal blocks for precise operation, the interferometer was mounted on two extremely rigid positioning tables (one with a sleeve bearings) and was controlled by a feedback positioning system using phase-lock interferometry. The imaging system produced a 60x30 mm interference pattern with 60% visibility using 17.7 keV monochromatic synchrotron X-rays at the Photon Factory. It was then used to perform radiographic observation (i.e., phase mapping) of rat liver vessels. These results indicate that this imaging system can be used to perform observations of large and in vivo biological samples

  16. Resonant Inelastic X-ray Scattering of Rare-Earth and Copper Systems

    International Nuclear Information System (INIS)

    Kvashnina, Kristina

    2007-01-01

    Rare earths and copper systems were studied using X-ray absorption spectroscopy (XAS) and resonant inelastic X-ray scattering (RIXS). The use of monochromased synchotron radiation and improved energy resolution for RIXS made possible to obtain valuable information on the electronic structure in 4f, 5f and 3d systems. Experimental results for rare-earths (Ho, Gd, Cm, U, Np, Pu) were analyzed by atomic multiplet theory based on the Hartree-Fock calculations. The inelastic scattering structures in RIXS spectra at 5d edge of actinides found to be sensitive to actinide oxidation states in different systems. Comparison of experimental and calculated Cm 5d RIXS spectra gave direct information about valency of the 248-curium isotope in oxide. Scientific understanding of processes that control chemical changes of radioactive species from spent fuel is improved by studying interactions of actinide ions (U, Np, Pu) with corroded iron surfaces. RIXS measurements at the actinide 5d edge found to be sensitive to actinide oxidation states in different systems. Comparison of experimental and calculated Cm 5d RIXS spectra gave direct information about valency of the 248 curium isotope in oxide. Scientific understanding of processes that control chemical changes of radioactive species from spent fuel is improved by studying interactions of actinide ions (U, Np, Pu) with corroded iron surfaces. RIXS measurements at the actinide 5d edge indicate the reduction of U(VI), NP(V) and Pu(VI) to U(IV), Np(IV) and Pu(IV) by presence of iron ions. This thesis is also addressed to the study of changes in the electronic structure of copper films during interaction with synthetic groundwater solutions. The surface modifications induced by chemical reactions of oxidized 100 Angstrom Cu films with CL - , SO 4 2- and HCO 3 - ions in aqueous solutions with various concentrations were studied in-situ using XAS. It was shown that the pH value, the concentration of Cl - ion and presence of HC 3 - ion in

  17. Resonant Inelastic X-ray Scattering of Rare-Earth and CopperSystems

    Energy Technology Data Exchange (ETDEWEB)

    Kvashnina, Kristina [Uppsala Univ. (Sweden)

    2007-07-11

    Rare earths and copper systems were studied using X-ray absorption spectroscopy (XAS) and resonant inelastic X-ray scattering (RIXS). The use of monochromased synchotron radiation and improved energy resolution for RIXS made possible to obtain valuable information on the electronic structure in 4f, 5f and 3d systems. Experimental results for rare-earths (Ho, Gd, Cm, U, Np, Pu) were analyzed by atomic multiplet theory based on the Hartree-Fock calculations. The inelastic scattering structures in RIXS spectra at 5d edge of actinides found to be sensitive to actinide oxidation states in different systems. Comparison of experimental and calculated Cm 5d RIXS spectra gave direct information about valency of the 248-curium isotope in oxide. Scientific understanding of processes that control chemical changes of radioactive species from spent fuel is improved by studying interactions of actinide ions (U, Np, Pu) with corroded iron surfaces. RIXS measurements at the actinide 5d edge found to be sensitive to actinide oxidation states in different systems. Comparison of experimental and calculated Cm 5d RIXS spectra gave direct information about valency of the 248 curium isotope in oxide. Scientific understanding of processes that control chemical changes of radioactive species from spent fuel is improved by studying interactions of actinide ions (U, Np, Pu) with corroded iron surfaces. RIXS measurements at the actinide 5d edge indicate the reduction of U(VI), NP(V) and Pu(VI) to U(IV), Np(IV) and Pu(IV) by presence of iron ions. This thesis is also addressed to the study of changes in the electronic structure of copper films during interaction with synthetic groundwater solutions. The surface modifications induced by chemical reactions of oxidized 100 Angstrom Cu films with CL-, SO42- and HCO3- ions in aqueous solutions with various concentrations were studied in-situ using XAS. It was shown that the pH value, the

  18. Proposal for electron beam induced remote sensing x-ray fluorescence investigation of minor bodies in the solar system

    International Nuclear Information System (INIS)

    Hrehuss, G.; Gombosi, T.I.; Naday, I.; Pogany, L.; Szegoe, K.

    1983-11-01

    The composition of the surface material of minor bodies in the solar system can be measured using a semiconductor soft x-ray spectrometer mounted on the space probe. The characteristic x-rays are excited by a 20 kV low current electron beam of a space-born electron gun. After the description of the main features of the technique, estimations on its sensitivity, supported by a model experiment, are given. The minimum fly-by distance to apply this method can be estimated as a few kilometers. (author)

  19. Three-dimensional visualization of material flow during friction stir welding by two pairs of X-ray transmission systems

    International Nuclear Information System (INIS)

    Morisada, Y.; Fujii, H.; Kawahito, Y.; Nakata, K.; Tanaka, M.

    2011-01-01

    Material flow during friction stir welding is crucial to obtaining sound joints. However, this phenomenon is still not fully understood despite many investigations and numerous models. In this study, the material flow is three-dimensionally visualized by X-ray radiography using a tiny spherical tungsten tracer. The movement of the tracer during the friction stir welding is observed by two pairs of X-ray transmission real-time imaging systems. The three-dimensional material flow is obtained by following the locus of the tracer.

  20. A reference sample for investigating the stability of the imaging system of x-ray computed tomography

    International Nuclear Information System (INIS)

    Sun, Wenjuan; Brown, Stephen; Flay, Nadia; McCarthy, Michael; McBride, John

    2016-01-01

    The use of x-ray computed tomography for dimensional measurements associated with engineering applications has flourished in recent years. However, error sources associated with the technology are not well understood. In this paper, a novel two-sphere reference sample has been developed and used to investigate the stability of the imaging system that consists of an x-ray tube and a detector. In contrast with other research work reported, this work considered relative positional variation along the x -, y - and z -axes. This sample is a significant improvement over the one sphere sample proposed previously, which can only be used to observe the stability of the imaging system along x - and y -axes. Temperature variations of different parts of the system have been monitored and the relationship between temperature variations and x-ray image stability has been studied. Other effects that may also influence the stability of the imaging system have been discussed. The proposed reference sample and testing method are transferable to other types of x-ray computed tomography systems, for example, systems with transmission targets and systems with sub-micrometre focal spots. (paper)

  1. From quality control to quality systems in x-ray radiology. Step by step approach

    International Nuclear Information System (INIS)

    Gendrutis Morkunas; Julius Ziliukas

    2007-01-01

    Complete test of publication follows. Quality systems in x-ray radiology as in any area of medical exposure is an important tool of optimization of radiation protection. Creation of these systems is related with a number of problems: limited resources, lack of knowledge and experience, negative attitude of hospitals staff and administration, lack of advice from outside. Problems related with transitionary period might be softened by the step by step approach. The following steps might be indicated: providing information on quality systems to hospital staff and administration, simple quality control procedures done by outside experts in hospitals, preparation of quality related procedures by hospital staff, practical implementation of quality control procedures done by hospital staff, preparation of quality manual by hospital staff, its integration into common quality system of hospital (if it is available) and constant development, measurements of performance indicators (e.g., patients' doses) and introduction of corrective measures if necessary, dissemination of experience by expert organizations and more advanced hospitals. These steps are to be discussed in the presentations based on Lithuanian experience since 1998.

  2. Ion, X-ray, UV and Neutron Microbeam Systems for Cell Irradiation.

    Science.gov (United States)

    Bigelow, A W; Randers-Pehrson, G; Garty, G; Geard, C R; Xu, Y; Harken, A D; Johnson, G W; Brenner, D J

    2010-08-08

    The array of microbeam cell-irradiation systems, available to users at the Radiological Research Accelerator Facility (RARAF), Center for Radiological Research, Columbia University, is expanding. The HVE 5MV Singletron particle accelerator at the facility provides particles to two focused ion microbeam lines: the sub-micron microbeam II and the permanent magnetic microbeam (PMM). Both the electrostatic quadrupole lenses on the microbeam II system and the magnetic quadrupole lenses on the PMM system are arranged as compound lenses consisting of two quadrupole triplets with "Russian" symmetry. Also, the RARAF accelerator is a source for a proton-induced x-ray microbeam (undergoing testing) and is projected to supply protons to a neutron microbeam based on the (7)Li(p, n)(7)Be nuclear reaction (under development). Leveraging from the multiphoton microscope technology integrated within the microbeam II endstation, a UV microspot irradiator - based on multiphoton excitation - is available for facility users. Highlights from radiation-biology demonstrations on single living mammalian cells are included in this review of microbeam systems for cell irradiation at RARAF.

  3. Laser System for Photoelectron and X-Ray Production in the PLEIADES Compton Light Source

    CERN Document Server

    Gibson, David J; Betts, S; Crane, John; Jovanovic, Igor

    2005-01-01

    The PLEIADES (Picosecond Laser-Electron Interaction for the Dynamic Evaluation of Structures) facility provides tunable short x-ray pulses with energies of 30-140 keV and pulse durations of 0.3 - 5 ps by scattering an intense, ultrashort laser pulse off a 35-75 MeV electron beam. Synchronization of the laser and electron beam is obtained by using a photoinjector gun, and using the same laser system to generate the electrons and the scattering laser. The Ti:Sapphire, chirped pulse amplification based 500 mJ, 50 fs, 810 nm scattering laser and the similar 300 μJ, 5 ps, 266 nm photoinjector laser systems are detailed. Additionally, an optical parametric chirped pulse amplification (OPCPA) system is studied as a replacement for part of the scattering laser front end. Such a change would significantly simplify the set-up the laser system by removing the need for active switching optics, as well as increase the pre-pulse contrast ratio which will be important when part of the scattering laser is used as a...

  4. Curcumin-β-cyclodextrin inclusion complex: stability, solubility, characterisation by FT-IR, FT-Raman, X-ray diffraction and photoacoustic spectroscopy, and food application.

    Science.gov (United States)

    Mangolim, Camila Sampaio; Moriwaki, Cristiane; Nogueira, Ana Claudia; Sato, Francielle; Baesso, Mauro Luciano; Neto, Antônio Medina; Matioli, Graciette

    2014-06-15

    Curcumin was complexed with β-CD using co-precipitation, freeze-drying and solvent evaporation methods. Co-precipitation enabled complex formation, as indicated by the FT-IR and FT-Raman techniques via the shifts in the peaks that were assigned to the aromatic rings of curcumin. In addition, photoacoustic spectroscopy and X-ray diffraction, with the disappearance of the band related to aromatic rings, by Gaussian fitting, and modifications in the spectral lines, respectively, also suggested complex formation. The possible complexation had an efficiency of 74% and increased the solubility of the pure colourant 31-fold. Curcumin-β-CD complex exhibited a sunlight stability 18% higher than the pure colourant. This material was stable to pH variations and storage at -15 and 4°C. With an isothermal heating at 100 and 150°C for 2h, the material exhibited a colour retention of approximately 99%. The application of curcumin-β-CD complex in vanilla ice creams intensified the colour of the products and produced a great sensorial acceptance. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Slit-Jaw Imaging System

    Science.gov (United States)

    Wilkerson, P.; Champey, P. R.; Winebarger, A. R.; Kobayashi, K.; Savage, S. L.

    2017-12-01

    The Marshall Grazing Incidence X-ray Spectrometer is a NASA sounding rocket payload providing a 0.6 - 2.5 nm spectrum with unprecedented spatial and spectral resolution. The instrument is comprised of a novel optical design, featuring a Wolter1 grazing incidence telescope, which produces a focused solar image on a slit plate, an identical pair of stigmatic optics, a planar diffraction grating and a low-noise detector. When MaGIXS flies on a suborbital launch in 2019, a slit-jaw camera system will reimage the focal plane of the telescope providing a reference for pointing the telescope on the solar disk and aligning the data to supporting observations from satellites and other rockets. The telescope focuses the X-ray and EUV image of the sun onto a plate covered with a phosphor coating that absorbs EUV photons, which then fluoresces in visible light. This 10-week REU project was aimed at optimizing an off-axis mounted camera with 600-line resolution NTSC video for extremely low light imaging of the slit plate. Radiometric calculations indicate an intensity of less than 1 lux at the slit jaw plane, which set the requirement for camera sensitivity. We selected a Watec 910DB EIA charge-coupled device (CCD) monochrome camera, which has a manufacturer quoted sensitivity of 0.0001 lux at F1.2. A high magnification and low distortion lens was then identified to image the slit jaw plane from a distance of approximately 10 cm. With the selected CCD camera, tests show that at extreme low-light levels, we achieve a higher resolution than expected, with only a moderate drop in frame rate. Based on sounding rocket flight heritage, the launch vehicle attitude control system is known to stabilize the instrument pointing such that jitter does not degrade video quality for context imaging. Future steps towards implementation of the imaging system will include ruggedizing the flight camera housing and mounting the selected camera and lens combination to the instrument structure.

  6. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  7. Development of a portable system of grazing exit X-Ray fluorescence applied to environmental and biological studies

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Ramon S.; Oliveira, Davi F.; Anjos, Marcelino J. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Instituto de Fisica; Assis, Joaquim T., E-mail: ramonziosp@yahoo.com.br, E-mail: davi.oliveira@uerj.br, E-mail: marcelin@uerj.br, E-mail: joaquim.iprj@gmail.com [Universidade do Estado do Rio de Janeiro (UERJ), Nova Friburgo, RJ (Brazil). Instituto Politécnico

    2017-07-01

    In this study was developed a portable system of grazing exit X-ray fluorescence (geometric 90° - 0°) that will be applied in environmental studies (aerosol samples) and biological studies. GE-XRF portable system is formed by a mini X-ray tube of low power (anode of Au, maximum voltage and current of 50 kV and 200 μA, respectively) and a SiPIN detector (model XR-100CR of the Amptek). The reflectors used as sample support (sampler carrier) were quartz discs with 25.4 mm diameter and 3.0 mm thickness. The grazing exit angle was experimentally determined by measuring a cooper solution (10 μg.g{sup -1}). The system of GE-XRF proved to be quite stable and reproducible. It was calculated the sensibility curve of the system using multielement solutions. The accuracy of the system was checked using multielement reference solution as standard reference material. The relative errors between measured and certified values are in the range of 4 to 19%. The first results showed a background was drastically reduced at grazing exit angles, enabling trace elemental analysis. This paper shows that it is possible to produce a portable system of grazing exit X-ray fluorescence compact, efficient, low-cost and easy-to-handle instrumentation using a low-power X-ray tube and a SiPIN compact detector. (author)

  8. Design and validation of inert homemade explosive simulants for X-ray-based inspection systems

    Science.gov (United States)

    Faust, Anthony A.; Nacson, Sabatino; Koffler, Bruce; Bourbeau, Éric; Gagne, Louis; Laing, Robin; Anderson, C. J.

    2014-05-01

    Transport Canada (TC), the Canadian Armed Forces, and other public security agencies have an interest in the assessment of the potential utility of advanced explosives detection technologies to aid in the detection and interdiction of commercial grade, military grade, and homemade or improvised explosives (HME or IE). The availability of suitable, non-hazardous, non-toxic, explosive simulants is of concern when assessing the potential utility of such detection systems. Lack of simulants limits the training opportunities, and ultimately the detection probability, of security personnel using these systems. While simulants for commercial and military grade explosives are available for a wide variety of detection technologies, the design and production of materials to simulate improvised explosives has not kept pace with this emerging threat. Funded by TC and the Canadian Safety and Security Program, Defence Research and Development Canada (DRDC), Visiontec Systems, and Optosecurity engaged in an effort to develop inert, non-toxic Xray interrogation simulants for IE materials such as ammonium nitrate, potassium chlorate, and triacetone triperoxide. These simulants were designed to mimic key X-ray interrogation-relevant material properties of real improvised explosives, principally their bulk density and effective atomic number. Different forms of the simulants were produced and tested, simulating the different explosive threat formulations that could be encountered by front line security workers. These simulants comply with safety and stability requirements, and as best as possible match form and homogeneity. This paper outlines the research program, simulant design, and validation.

  9. An X-Ray computed tomography/positron emission tomography system designed specifically for breast imaging.

    Science.gov (United States)

    Boone, John M; Yang, Kai; Burkett, George W; Packard, Nathan J; Huang, Shih-ying; Bowen, Spencer; Badawi, Ramsey D; Lindfors, Karen K

    2010-02-01

    Mammography has served the population of women who are at-risk for breast cancer well over the past 30 years. While mammography has undergone a number of changes as digital detector technology has advanced, other modalities such as computed tomography have experienced technological sophistication over this same time frame as well. The advent of large field of view flat panel detector systems enable the development of breast CT and several other niche CT applications, which rely on cone beam geometry. The breast, it turns out, is well suited to cone beam CT imaging because the lack of bones reduces artifacts, and the natural tapering of the breast anteriorly reduces the x-ray path lengths through the breast at large cone angle, reducing cone beam artifacts as well. We are in the process of designing a third prototype system which will enable the use of breast CT for image guided interventional procedures. This system will have several copies fabricated so that several breast CT scanners can be used in a multi-institutional clinical trial to better understand the role that this technology can bring to breast imaging.

  10. High speed imaging of dynamic processes with a switched source x-ray CT system

    International Nuclear Information System (INIS)

    Thompson, William M; Lionheart, William R B; Morton, Edward J; Cunningham, Mike; Luggar, Russell D

    2015-01-01

    Conventional x-ray computed tomography (CT) scanners are limited in their scanning speed by the mechanical constraints of their rotating gantries and as such do not provide the necessary temporal resolution for imaging of fast-moving dynamic processes, such as moving fluid flows. The Real Time Tomography (RTT) system is a family of fast cone beam CT scanners which instead use multiple fixed discrete sources and complete rings of detectors in an offset geometry. We demonstrate the potential of this system for use in the imaging of such high speed dynamic processes and give results using simulated and real experimental data. The unusual scanning geometry results in some challenges in image reconstruction, which are overcome using algebraic iterative reconstruction techniques and explicit regularisation. Through the use of a simple temporal regularisation term and by optimising the source firing pattern, we show that temporal resolution of the system may be increased at the expense of spatial resolution, which may be advantageous in some situations. Results are given showing temporal resolution of approximately 500 µs with simulated data and 3 ms with real experimental data. (paper)

  11. An evaluation of the EOS X-ray imaging system in pelvimetry

    International Nuclear Information System (INIS)

    Sigmann, M.H.; Runge, M.; Peyron, C.; Delabrousse, E.; Riethmuller, D.; Aubry, S.

    2014-01-01

    Objectives: To demonstrate the reliability of the EOS imaging system in measuring the internal diameters of the bony pelvis. Materials and methods: A prospective study comparing the results of the pelvimetry of 18 dry pelvises carried out on the EOS imaging system to measurements taken manually and using the two current gold standard CT methods. Pelvi-metric measurements of each pelvic bone were obtained using four methods and compared: direct manual measurements, spiral and sequential CT pelvimetry, and 2D-3D low-dose bi-planar X-rays. The various obstetric diameters were measured to the millimetre and compared. Results: There was no significant difference in the different diameters assessed, with the exception of the inter-spinous diameter. There was a highly significant correlation (P < 0.001) between the values measured manually and by EOS for the Magnin index (Pearson = 0.98), the obstetric conjugate diameter (Pearson = 0.99), and the median transverse diameter (Pearson = 0.87). Conclusion: The EOS imaging system allows for an ex vivo determination of the obstetrical diameters that is reliable enough to estimate obstetric prognosis, producing comparable measurements to CT. In view of concerns about protection from radiation, this low-dose imaging technique could become, after in vivo prospective validation, the new gold standard for pelvimetry and therefore a good alternative to CT. (authors)

  12. X-ray focal spot reconstruction by circular penumbra analysis-Application to digital radiography systems.

    Science.gov (United States)

    Di Domenico, Giovanni; Cardarelli, Paolo; Contillo, Adriano; Taibi, Angelo; Gambaccini, Mauro

    2016-01-01

    The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. The method was proven to be effective for simulated

  13. X-ray focal spot reconstruction by circular penumbra analysis—Application to digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Di Domenico, Giovanni, E-mail: didomenico@fe.infn.it; Cardarelli, Paolo; Taibi, Angelo; Gambaccini, Mauro [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, via Saragat 1, FE I-44122, Italy and INFN - sezione di Ferrara, via Saragat 1, FE I-44122 (Italy); Contillo, Adriano [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, via Saragat 1, FE I-44122 (Italy)

    2016-01-15

    Purpose: The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. Methods: The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. Results: In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. Conclusions: The method was

  14. Development of a digital panoramic X-ray imaging system of adaptive image layers for dental applications

    International Nuclear Information System (INIS)

    Choi, S.I.; Park, Y.O.; Cho, H.S.; Oh, J.E.; Cho, H.M.; Hong, D.K.; Lee, M.S.; Yang, Y.J.; Je, U.K.; Kim, D.S.; Lee, H.K.

    2011-01-01

    As a continuation of our digital radiographic sensor R and D, we have developed a prototyped digital panoramic X-ray imaging system for dental applications. The imaging system consists of a slit-collimated X-ray generator with a 0.4 mm focal spot size and a 3.5 mm Al filtration, a linear-array typed CMOS imager with a 48x48 μm 2 pixel size and a 128 (in the scan direction)x3072 (in the vertical direction) pixel format, a series of microstep motors for the precise motion control of the imaging system, and the designed sequences for the motion control and pixel readout required to make a specific plane of interest (POI) to be focused. With the several test phantoms we designed, we obtained useful digital panoramic X-ray images by moving the X-ray generator and the CMOS imager along a continuously sliding rotational center. In this study, we demonstrated that the prototype system can be applicable to any shaped POI or multi-POIs simultaneously to be focused, provided that adequate sequences for motion control and pixel readout are designed. We expect that the imaging system will be useful for our ongoing applications of dental panoramic radiography and nondestructive testing.

  15. Support system for welded part inspection using X-ray. Simplified inspection system which does not need skilled workers

    International Nuclear Information System (INIS)

    Suga, Yasuo

    1995-01-01

    X-ray radiography has the excellent ability for operation and recording, accordingly, it has been used widely in industrial fields, but for deciding the presence of defects and their kinds and shapes from X-ray films, skilled workers are required. Recently because of the shortage of skilled workers and the increase of inspection efficiency, the necessity of its automation increased. The images of the films of the X-ray inspection of welded part are photographed with a CCD camera, and these are taken in a personal computer as the image data, then image processing is applied to them, and defect images are extracted automatically. Further, the technique of displaying the images so that inspectors can recognize them easily is devised. These procedures were examined. The constitution of the system the way of thinking in developing the system, the acquiring of high contrast images, the emphasis of defect images, the elimination of noise the treatment of emphasizing nuclear defect images, the elimination of background and the extraction of defect images, the results of the processing and image display are reported. The order of processes, the kind of a filter used and so on can be changed according to the purpose, the kind of welding and the image quality of films. (K.I.)

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  17. Ultrasoft x-ray imaging system for the National Spherical Torus Experiment

    Science.gov (United States)

    Stutman, D.; Finkenthal, M.; Soukhanovskii, V.; May, M. J.; Moos, H. W.; Kaita, R.

    1999-01-01

    A spectrally resolved ultrasoft x-ray imaging system, consisting of arrays of high resolution (the National Spherical Torus Experiment. Initially, three poloidal arrays of diodes filtered for C 1s-np emission will be implemented for fast tomographic imaging of the colder start-up plasmas. Later on, mirrors tuned to the C Lyα emission will be added in order to enable the arrays to "see" the periphery through the hot core and to study magnetohydrodynamic activity and impurity transport in this region. We also discuss possible core diagnostics, based on tomographic imaging of the Lyα emission from the plume of recombined, low Z impurity ions left by neutral beams or fueling pellets. The arrays can also be used for radiated power measurements and to map the distribution of high Z impurities injected for transport studies. The performance of the proposed system is illustrated with results from test channels on the CDX-U spherical torus at Princeton Plasma Physics Laboratory.

  18. Powerful conveyer belt real-time online detection system based on x-ray

    Science.gov (United States)

    Rong, Feng; Miao, Chang-yun; Meng, Wei

    2009-07-01

    The powerful conveyer belt is widely used in the mine, dock, and so on. After used for a long time, internal steel rope of the conveyor belt may fracture, rust, joints moving, and so on .This would bring potential safety problems. A kind of detection system based on x-ray is designed in this paper. Linear array detector (LDA) is used. LDA cost is low, response fast; technology mature .Output charge of LDA is transformed into differential voltage signal by amplifier. This kind of signal have great ability of anti-noise, is suitable for long-distance transmission. The processor is FPGA. A IP core control 4-channel A/D convertor, achieve parallel output data collection. Soft-core processor MicroBlaze which process tcp/ip protocol is embedded in FPGA. Sampling data are transferred to a computer via Ethernet. In order to improve the image quality, algorithm of getting rid of noise from the measurement result and taking gain normalization for pixel value is studied and designed. Experiments show that this system work well, can real-time online detect conveyor belt of width of 2.0m and speed of 5 m/s, does not affect the production. Image is clear, visual and can easily judge the situation of conveyor belt.

  19. A readout system for position sensitive measurements of X-ray using silicon strip detectors

    CERN Document Server

    Dabrowski, W; Grybos, P; Idzik, M; Kudlaty, J

    2000-01-01

    In this paper we describe the development of a readout system for X-ray measurements using silicon strip detectors. The limitation concerning the inherent spatial resolution of silicon strip detectors has been evaluated by Monte Carlo simulation and the results are discussed. The developed readout system is based on the binary readout architecture and consists of two ASICs: RX32 front-end chip comprising 32 channels of preamplifiers, shapers and discriminators, and COUNT32 counter chip comprising 32 20-bit asynchronous counters and the readout logic. This work focuses on the design and performance of the front-end chip. The RX32 chip has been optimised for a low detector capacitance, in the range of 1-3 pF, and high counting rate applications. It can be used with DC coupled detectors allowing the leakage current up to a few nA per strip. For the prototype chip manufactured in a CMOS process all basic parameters have been evaluated by electronic measurements. The noise below 140 el rms has been achieved for a ...

  20. Inspection surveys of x-ray inspection systems: results of five years and implications on future management of radiation risks

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    1999-01-01

    Until the mid-1980s, federal inspectors performed radiation surveys annually on individual x-ray inspection systems which were operated for security screening purposes in federal facilities nationwide, and problems identified were corrected. The surveys were undertaken because of perceived high radiation risks and a need to ensure worker and public external exposures were minimized. The x-ray inspection systems are federally regulated under the Radiation Emitting Devices (RED) Act and, initially they were assessed by model type against the design, construction and performance criteria specified in the applicable RED regulations (Schedule II, Part IV) and were found compliant. A subsequent study not only demonstrated a much lower radiation risk attributed to a combination of technological advances in x-ray system design with narrow primary beams, high efficiency detectors and image processing capability, but also stressed the need for proper equipment maintenance and continued education of operators and maintenance personnel. Survey frequency was thus reduced to once every 2-3 years in accordance with a 1993 federal operational standard (Safety Code 29). The radiation protection principles in Safety Code 29 are similar to those of the 1996 International Atomic Energy Agency (IAEA) Basic Safety Standards for the protection against ionizing radiation and the safety of radiation sources. The purpose of this study was to assess inspection-survey data from 1993 through 1997 to elicit guidance toward the future management of radiation risks associated with the operation of such x-ray systems. (author)

  1. Optimization of ion-optics system for x-ray quasi-monochromatic source on the basis of electrostatic accelerator

    Directory of Open Access Journals (Sweden)

    S. O. Vershynskyi

    2010-06-01

    Full Text Available Ion-optics system with two doublets of electrostatic quadrupole lenses for X-ray quasimonochromatic source was selected. Two variants of lens excitation for stigmatic focusing with two and four independent power supplies are considered. It is shown that using of four independent power supplies leads to improvement of focused ion beam parameters at converter.

  2. A new fully integrated X-ray irradiator system for dosimetric research

    International Nuclear Information System (INIS)

    Richter, D.; Mittelstraß, D.; Kreutzer, S.; Pintaske, R.; Dornich, K.; Fuchs, M.

    2016-01-01

    A fully housed X-ray irradiator was developed for use within lexsyg or Magnettech desktop equipment. The importance of hardening of the low energy photon radiation is discussed, its performance and feasibility is empirically shown and sustained by basic numerical simulations. Results of the latter for various materials are given for different X-ray source settings in order to provide estimates on the required setup for the irradiation of different geometries and materials. A Si-photodiode provides real-time monitoring of the X-ray-irradiator designed for use in dosimetric dating and other dosimetric application where irradiation of small samples or dosemeters is required. - Highlights: • Bench top X-ray irradiator provides variable dose-rates. • Simulation of low energy photon irradiation and hardening of X-ray. • Al-hardening for the irradiation of H_2O, BeO, Al_2O_3, quartz, feldspars and zircon. • Dosimetric dating equipment for luminescence and ESR.

  3. Calibration of the Verification Engineering Test Article-I (VETA-I) for AXAF using the VETA-I X-ray Detection System

    Science.gov (United States)

    Kellogg, E.; Brissenden, R.; Flanagan, K.; Freeman, M.; Hughes, J.; Jones, M.; Ljungberg, M.; Mckinnon, P.; Podgorski, W.; Schwartz, D.

    1992-01-01

    Advanced X-ray Astrophysics Facility (AXAF) X-ray optics testing is conducted by VETA-I, which consists of six nested Wolter type I grazing-incidence mirrors; VETA's X-ray Detection System (VXDS) in turn measures the imaging properties of VETA-I, yielding FWHM and encircled energy of the X-ray image obtained, as well as its effective area. VXDS contains a high resolution microchannel plate imaging X-ray detector and a pinhole scanning system in front of proportional-counter detectors. VETA-I's X-ray optics departs from the AXAF flight configuration in that it uses a temporary holding fixture; its mirror elements are not cut to final length, and are not coated with the metal film used to maximize high-energy reflection.

  4. Development of a Reference System for the determination of the personal dose equivalent and the constancy of X- Ray beams

    International Nuclear Information System (INIS)

    Vivolo, Vitor

    2006-01-01

    A reference system for the determination of the personal dose equivalent, Hp (10), and a quality control program of X-ray equipment used In radioprotection require the periodic verification of the X-ray beams constancy. In this work, two parallel-plate ionization chambers were developed with inner electrodes of different materials, and inserted into PMMA slab phantoms. One ionization chamber was developed with inner carbon electrodes and the other with inner aluminium electrodes. The two ionization chambers can be used as a Tandem system. The different energy response of the two ionization chambers allowed the development of the Tandem system that is very useful for the checking of the constancy of beam qualities. Standard intermediary energy X-ray beams (from 48 keV to 118 keV), radioprotection level, were established through the development of a dosimetric methodology and the analysis of their physical parameters. The ionization chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams (radioprotection, diagnostic radiology, mammography and radiotherapy levels) in accordance to international recommendations. They presented good performance. The determination procedure of personal dose equivalent, Hp (10), was established. (author)

  5. Measurement of position dependence of spectral distribution in primary X-ray beam of CT system using compton spectroscopy

    International Nuclear Information System (INIS)

    Matsumoto, Masao; Maeda, Koji; Maeda, Koji

    2005-01-01

    Our purpose is to acquire the diagnostic x-ray spectra of the CT system easily under clinical conditions by Compton scatter spectroscopy using a high resolution Schottky CdTe detector recently developed and to estimate the quality and quantity of these spectra compared the relative exposure measured using an ionization chamber with curves measured by the reconstructed spectra. Although the spectral broadening and the fluctuation were slightly shown, the errors of the relative exposure were under 10%. Though the experimental arrangement of this method is so easy and reconstructed algorithm is simple, these results suggested that this method is little influenced by the variation of dose rates or property of the incident x rays. We therefore propose that the Compton scatter spectroscopy with the newly developed Schottky CdTe detector is suitable for measuring the diagnostic x-ray spectra of the CT system under the clinical conditions and useful for quality assurance and quality control of the clinical x-ray CT system. (author)

  6. MCNP6 simulation of radiographs generated from megaelectron volt X-rays for characterizing a computed tomography system

    Science.gov (United States)

    Dooraghi, Alex A.; Tringe, Joseph W.

    2018-04-01

    To evaluate conventional munition, we simulated an x-ray computed tomography (CT) system for generating radiographs from nominal x-ray energies of 6 or 9 megaelectron volts (MeV). CT simulations, informed by measured data, allow for optimization of both system design and acquisition techniques necessary to enhance image quality. MCNP6 radiographic simulation tools were used to model ideal detector responses (DR) that assume either (1) a detector response proportional to photon flux (N) or (2) a detector response proportional to energy flux (E). As scatter may become significant with MeV x-ray systems, simulations were performed with and without the inclusion of object scatter. Simulations were compared against measurements of a cylindrical munition component principally composed of HMX, tungsten and aluminum encased in carbon fiber. Simulations and measurements used a 6 MeV peak energy x-ray spectrum filtered with 3.175 mm of tantalum. A detector response proportional to energy which includes object scatter agrees to within 0.6 % of the measured line integral of the linear attenuation coefficient. Exclusion of scatter increases the difference between measurement and simulation to 5 %. A detector response proportional to photon flux agrees to within 20 % when object scatter is included in the simulation and 27 % when object scatter is excluded.

  7. A portable organic plastic scintillator dosimetry system for low energy X-rays: a feasibility study using an intraoperative X-ray unit as the radiation source

    International Nuclear Information System (INIS)

    Williams, Kerry; Robinson, Neil; Trapp, Jamie; Geso, Moshi; Ackerly, Trevor; Das, Ram; Kemp, Penny

    2007-01-01

    The effective use of near water equivalent organic plastic scintillators (OPS) for radiation dosimetry with high-energy sources under laboratory conditions is recognized. In this work, an OPS-based dosimeter using a photodiode combined with improved solid state detection and signal processing techniques has been developed; it offers the potential for the construction of a stable and fully portable dosimeter which will extend the useful range of measurement beyond the usual MeV area and provide reliable readings down to sub-100 keV X-ray energy levels. In these experiments, the instrument described has been used for the dosimetry of INTRABEAM intraoperative radiotherapy (IORT) equipment at distances as low as 1.8 mm from the effective source, i.e., 0.2 mm from the X-ray probe surface. Comparison is shown with dosimetry measurements made using the calibrated reference ion chamber supplied by the IORT equipment manufacturer. (author)

  8. Accelerated Synchrotron X-ray Diffraction Data Analysis on a Heterogeneous High Performance Computing System

    Energy Technology Data Exchange (ETDEWEB)

    Qin, J; Bauer, M A, E-mail: qin.jinhui@gmail.com, E-mail: bauer@uwo.ca [Computer Science Department, University of Western Ontario, London, ON N6A 5B7 (Canada)

    2010-11-01

    The analysis of synchrotron X-ray Diffraction (XRD) data has been used by scientists and engineers to understand and predict properties of materials. However, the large volume of XRD image data and the intensive computations involved in the data analysis makes it hard for researchers to quickly reach any conclusions about the images from an experiment when using conventional XRD data analysis software. Synchrotron time is valuable and delays in XRD data analysis can impact decisions about subsequent experiments or about materials that they are investigating. In order to improve the data analysis performance, ideally to achieve near real time data analysis during an XRD experiment, we designed and implemented software for accelerated XRD data analysis. The software has been developed for a heterogeneous high performance computing (HPC) system, comprised of IBM PowerXCell 8i processors and Intel quad-core Xeon processors. This paper describes the software and reports on the improved performance. The results indicate that it is possible for XRD data to be analyzed at the rate it is being produced.

  9. Accelerated Synchrotron X-ray Diffraction Data Analysis on a Heterogeneous High Performance Computing System

    International Nuclear Information System (INIS)

    Qin, J; Bauer, M A

    2010-01-01

    The analysis of synchrotron X-ray Diffraction (XRD) data has been used by scientists and engineers to understand and predict properties of materials. However, the large volume of XRD image data and the intensive computations involved in the data analysis makes it hard for researchers to quickly reach any conclusions about the images from an experiment when using conventional XRD data analysis software. Synchrotron time is valuable and delays in XRD data analysis can impact decisions about subsequent experiments or about materials that they are investigating. In order to improve the data analysis performance, ideally to achieve near real time data analysis during an XRD experiment, we designed and implemented software for accelerated XRD data analysis. The software has been developed for a heterogeneous high performance computing (HPC) system, comprised of IBM PowerXCell 8i processors and Intel quad-core Xeon processors. This paper describes the software and reports on the improved performance. The results indicate that it is possible for XRD data to be analyzed at the rate it is being produced.

  10. Radiation dose to procedural personnel and patients from an X-ray volume imaging system

    International Nuclear Information System (INIS)

    Paul, Jijo; Mbalisike, Emmanuel C.; Vogl, Thomas J.

    2013-01-01

    To evaluate the radiation dose received by procedural personnel and patients from an X-ray volume imaging (XVI) system during interventional procedures. Forty patients were examined using catheter angiography (group A), digital subtraction angiography (group B) and cone-beam CT (CBCT, group C). Doses to procedural personnel (using thermo-luminescent dosimeters, TLDs) and patients were estimated. Image quality and lesion delineation were assessed using objective and subjective methods. Shapiro-Wilk, two-sided Student's t and Wilcoxon matched-pairs tests were used to test statistical significance. Doses (milligrays) measured in the hands and left knee of the interventionist were higher than those in an assistant physician (P < 0.05). Doses (dose-area product and skin entry dose) were lower in group A and higher in C compared with other groups; moreover, comparison among the groups were significant (all P = 0.0001). Subjective and objective lesion delineation showed significant results (all P < 0.05) among the tumour types considered. Image quality estimation showed the opposite results for objective and subjective analysis. More doses were obtained for hands of the procedural personnel compared to other anatomical regions measured. Catheter angiography showed lower dose compared with other imaging groups examined. Lesion delineation was clearly possible using CBCT. Objective and subjective analysis showed the opposite results regarding image quality because of higher noise levels and artefacts. (orig.)

  11. Developments in expert systems for automatic examination of samples by X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Castle, J.E.

    2010-01-01

    A brief introduction establishes the need for automatic interrogation of the X-ray photoelectron spectrum (XPS) during acquisition, to provide, immediately, the type of information required by users from a wide range of disciplines in science and technology. The review of progress in achieving this shows that progress has been made in demonstrating the use of simple Rules to extract useful information from the survey scan and to manipulate this to, for example, estimate contamination and film thicknesses on a surface. However it is argued that the essential next step is to establish a data base of the information that users from the differing fields expect to obtain from their use of XPS. Some examples of what the information might be is given for a number of fields such as Adhesion Science, Catalyst surfaces, and Bio-Systems. It is suggested that this list should be greatly expanded to provide the information in the form of Goals, each representing a relatively small step in interpretation of the data so as to achieve the required characterisation of the surface. Finally an example is given, by way of verification of a Rule base for metals and alloys, of how information in the survey scan compares with that obtained from curve fitted, high resolution, scans through individual peaks.

  12. ATHENA: system design and implementation for a next generation x-ray telescope

    Science.gov (United States)

    Ayre, M.; Bavdaz, M.; Ferreira, I.; Wille, E.; Lumb, D.; Linder, M.

    2015-08-01

    ATHENA, Europe's next generation x-ray telescope, has recently been selected for the 'L2' slot in ESA's Cosmic Vision Programme, with a mandate to address the 'Hot and Energetic Universe' Cosmic Vision science theme. The mission is currently in the Assessment/Definition Phase (A/B1), with a view to formal adoption after a successful System Requirements Review in 2019. This paper will describe the reference mission architecture and spacecraft design produced during Phase 0 by the ESA Concurrent Design Facility (CDF), in response to the technical requirements and programmatic boundary conditions. The main technical requirements and their mapping to resulting design choices will be presented, at both mission and spacecraft level. An overview of the spacecraft design down to subsystem level will then be presented (including the telescope and instruments), remarking on the critically-enabling technologies where appropriate. Finally, a programmatic overview will be given of the on-going Assessment Phase, and a snapshot of the prospects for securing the `as-proposed' mission within the cost envelope will be given.

  13. X-ray microbeams: Tumor therapy and central nervous system research

    International Nuclear Information System (INIS)

    Dilmanian, F.A.; Qu, Y.; Liu, S.; Cool, C.D.; Gilbert, J.; Hainfeld, J.F.; Kruse, C.A.; Laterra, J.; Lenihan, D.; Nawrocky, M.M.; Pappas, G.; Sze, C.-I.; Yuasa, T.; Zhong, N.; Zhong, Z.; McDonald, J.W.

    2005-01-01

    Irradiation with parallel arrays of thin, planar slices of X-ray beams (microplanar beams, or microbeams) spares normal tissue, including the central nervous system (CNS), and preferentially damages tumors. The effects are mediated, at least in part, by the tissue's microvasculature that seems to effectively repair itself in normal tissue but fails to do so in tumors. Consequently, the therapeutic index of single-fraction unidirectional microbeam irradiations has been shown to be larger than that of single-fraction unidirectional unsegmented beams in treating the intracranial rat 9L gliosarcoma tumor model (9LGS) and the subcutaneous murine mammary carcinoma EMT-6. This paper presents results demonstrating that individual microbeams, or arrays of parallel ones, can also be used for targeted, selective cell ablation in the CNS, and also to induce demyelination. The results highlight the value of the method as a powerful tool for studying the CNS through selective cell ablation, besides its potential as a treatment modality in clinical oncology

  14. Application of newly developed Fluoro-QC software for image quality evaluation in cardiac X-ray systems.

    Science.gov (United States)

    Oliveira, M; Lopez, G; Geambastiani, P; Ubeda, C

    2018-05-01

    A quality assurance (QA) program is a valuable tool for the continuous production of optimal quality images. The aim of this paper is to assess a newly developed automatic computer software for image quality (IR) evaluation in fluoroscopy X-ray systems. Test object images were acquired using one fluoroscopy system, Siemens Axiom Artis model (Siemens AG, Medical Solutions Erlangen, Germany). The software was developed as an ImageJ plugin. Two image quality parameters were assessed: high-contrast spatial resolution (HCSR) and signal-to-noise ratio (SNR). The time between manual and automatic image quality assessment procedures were compared. The paired t-test was used to assess the data. p Values of less than 0.05 were considered significant. The Fluoro-QC software generated faster IQ evaluation results (mean = 0.31 ± 0.08 min) than manual procedure (mean = 4.68 ± 0.09 min). The mean difference between techniques was 4.36 min. Discrepancies were identified in the region of interest (ROI) areas drawn manually with evidence of user dependence. The new software presented the results of two tests (HCSR = 3.06, SNR = 5.17) and also collected information from the DICOM header. Significant differences were not identified between manual and automatic measures of SNR (p value = 0.22) and HCRS (p value = 0.46). The Fluoro-QC software is a feasible, fast and free to use method for evaluating imaging quality parameters on fluoroscopy systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  15. FORMATION OF BLACK HOLE LOW-MASS X-RAY BINARIES IN HIERARCHICAL TRIPLE SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Naoz, Smadar; Stephan, Alexander P. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States); Fragos, Tassos [Geneva Observatory, University of Geneva, Chemin des Maillettes 51, 1290 Sauverny (Switzerland); Geller, Aaron; Rasio, Frederic A., E-mail: snaoz@astro.ucla.edu [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA), Northwestern University, Evanston, IL 60201 (United States)

    2016-05-10

    The formation of black hole (BH) low-mass X-ray binaries (LMXB) poses a theoretical challenge, as low-mass companions are not expected to survive the common-envelope scenario with the BH progenitor. Here we propose a formation mechanism that skips the common-envelope scenario and relies on triple-body dynamics. We study the evolution of hierarchical triples following the secular dynamical evolution up to the octupole-level of approximation, including general relativity, tidal effects, and post-main-sequence evolution such as mass loss, changes to stellar radii, and supernovae. During the dynamical evolution of the triple system the “eccentric Kozai-Lidov” mechanism can cause large eccentricity excitations in the LMXB progenitor, resulting in three main BH-LMXB formation channels. Here we define BH-LMXB candidates as systems where the inner BH-companion star crosses its Roche limit. In the “eccentric” channel (∼81% of the LMXBs in our simulations) the donor star crosses its Roche limit during an extreme eccentricity excitation while still on a wide orbit. Second, we find a “giant” LMXB channel (∼11%), where a system undergoes only moderate eccentricity excitations but the donor star fills its Roche-lobe after evolving toward the giant branch. Third, we identify a “classical” channel (∼8%), where tidal forces and magnetic braking shrink and circularize the orbit to short periods, triggering mass-transfer. Finally, for the giant channel we predict an eccentric (∼0.3–0.6) preferably inclined (∼40°, ∼140°) tertiary, typically on a wide enough orbit (∼10{sup 4} au) to potentially become unbound later in the triple evolution. While this initial study considers only one representative system and neglects BH natal kicks, we expect our scenario to apply across a broad region of parameter space for triple-star systems.

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  17. X-ray and gamma radiography devices

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    When we are using this technique, we also must familiar with the device and instrument that used such as gamma projector, crawler, x-ray tubes and others. So this chapter discussed detailed on device used for radiography work. For the x-ray and gamma, their characteristics are same but the source to produce is a big different. X-ray produced from the machine meanwhile, gamma produce from the source such as Co-60 and IR-192. Both are electromagnetic waves. So, the reader can have some knowledge on what is x-ray tube, discrete x-ray and characteristic x-ray, how the machine works and how to control a machine, what is source for gamma emitter, how to handle the projector and lastly difference between x-ray and gamma. Of course this cannot be with the theory only, so detailed must be learned practically.

  18. Development of a plasma system as a source of radiation for X-ray microscopy

    International Nuclear Information System (INIS)

    Neff, W.; Lebert, R.; Holz, R.

    1992-01-01

    During the period of the report, an X-ray source was developed for a laboratory X-ray microscope based on a plasma focus. Nitrogen is used as the discharge gas. The Lyman α line (λ = 2.48 nm) of nitrogen ions N VII similar to hydrogen is used for the image in the microscope. This line is favourably situated at the start of the water window (2.33 - 4.37 nm), so that the microscope is particularly suitable for the examination of biological objects. (orig.) [de

  19. Introducing the ARL X'Tra x-ray diffraction system

    International Nuclear Information System (INIS)

    Harris, L.

    2002-01-01

    Full text: The ARL X'Tra is a state-of-the-art solution for powder X-ray diffraction in a large range of applications such as pharmaceuticals and biosciences, chemicals, earth sciences, semi-conductors, metallurgy and ceramics. The X'Tra offers the latest technology in key diffraction components to produce a high performance instrument at an affordable price. This presentation examines some of the hardware and performance features of this instrument. Copyright (2002) Australian X-ray Analytical Association Inc

  20. Workshop on the coupling of synchrotron radiation IR and X-rays with tip based scanning probe microscopies X-TIP

    Energy Technology Data Exchange (ETDEWEB)

    Comin, F.; Martinez-Criado, G.; Mundboth, K.; Susini, J. [European Synchrotron Radiation Facility (ESRF), 38 - Grenoble (France); Purans, J.; Sammelselg, V. [Tartu Univ. (Estonia); Chevrier, J.; Huant, S. [Universite Joseph-Fourier, Grenoble I, LEPES, 38 (France); Hamilton, B. [School of Electrical Engineering and Electronics, Manchester (United Kingdom); Saito, A. [Osaka Univ., RIKEN/SPring8 (Japan); Dhez, O. [OGG, INFM/CNR, 38 - Grenoble (France); Brocklesby, W.S. [Southampton Univ., Optoelectronics Research Centre (United Kingdom); Alvarez-Prado, L.M. [Ovieado, Dept. de Fisica (Spain); Kuzmin, A. [Institute of Solid State Physics - Riga (Latvia); Pailharey, D. [CRMC-N - CNRS, 13 - Marseille (France); Tonneau, D. [CRMCN - Faculte des sciences de Luminy, 13 - Marseille (France); Chretien, P. [Laboratoire de Genie Electrique de Paris, 75 - Paris (France); Cricenti, A. [ISM-CNR, Rome (Italy); DeWilde, Y. [ESPCI, 75 - Paris (France)

    2005-07-01

    The coupling of scanning probe microscopy (SPM) with synchrotron radiation is attracting increasing attention from nano-science community. By combining these 2 tools one can visualize, for example, the sample nano-structure prior to any X-ray characterization. Coupled with focusing devices or independently, SPM can provide spatial resolution below the optical limits. Furthermore, the possibility of employing SPM to manipulate nano-objects under X-ray beams is another exciting perspective. This document gathers the transparencies of 6 of the presentations made at the workshop: 1) the combination of atomic force microscopy and X-ray beam - experimental set-up and objectives; 2) the combination of scanning probe microscope and X-rays for detection of electrons; 3) towards soft X-ray scanning microscopy using tapered capillaries and laser-based high harmonic sources; 4) near-field magneto-optical microscopy; 5) near-field scanning optical microscopy - a brief overview -; and 6) from aperture-less near-field optical microscopy to infra-red near-field night vision. 4 posters entitled: 1) development of laboratory setup for X-ray/AFM experiments, 2) towards X-ray diffraction on single islands, 3) nano-XEOL using near-field detection, and 4) local collection with a STM tip of photoelectrons emitted by a surface irradiated by visible of UV laser beam, are included in the document.

  1. Workshop on the coupling of synchrotron radiation IR and X-rays with tip based scanning probe microscopies X-TIP

    International Nuclear Information System (INIS)

    Comin, F.; Martinez-Criado, G.; Mundboth, K.; Susini, J.; Purans, J.; Sammelselg, V.; Chevrier, J.; Huant, S.; Hamilton, B.; Saito, A.; Dhez, O.; Brocklesby, W.S.; Alvarez-Prado, L.M.; Kuzmin, A.; Pailharey, D.; Tonneau, D.; Chretien, P.; Cricenti, A.; DeWilde, Y.

    2005-01-01

    The coupling of scanning probe microscopy (SPM) with synchrotron radiation is attracting increasing attention from nano-science community. By combining these 2 tools one can visualize, for example, the sample nano-structure prior to any X-ray characterization. Coupled with focusing devices or independently, SPM can provide spatial resolution below the optical limits. Furthermore, the possibility of employing SPM to manipulate nano-objects under X-ray beams is another exciting perspective. This document gathers the transparencies of 6 of the presentations made at the workshop: 1) the combination of atomic force microscopy and X-ray beam - experimental set-up and objectives; 2) the combination of scanning probe microscope and X-rays for detection of electrons; 3) towards soft X-ray scanning microscopy using tapered capillaries and laser-based high harmonic sources; 4) near-field magneto-optical microscopy; 5) near-field scanning optical microscopy - a brief overview -; and 6) from aperture-less near-field optical microscopy to infra-red near-field night vision. 4 posters entitled: 1) development of laboratory setup for X-ray/AFM experiments, 2) towards X-ray diffraction on single islands, 3) nano-XEOL using near-field detection, and 4) local collection with a STM tip of photoelectrons emitted by a surface irradiated by visible of UV laser beam, are included in the document

  2. Method for spatially modulating X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2015-03-10

    A method and apparatus are provided for spatially modulating X-rays or X-ray pulses using microelectromechanical systems (MEMS) based X-ray optics. A torsionally-oscillating MEMS micromirror and a method of leveraging the grazing-angle reflection property are provided to modulate X-ray pulses with a high-degree of controllability.

  3. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  4. Beam monitor system for an x-ray free electron laser and compact laser

    Directory of Open Access Journals (Sweden)

    Y. Otake

    2013-04-01

    Full Text Available A beam-monitor system for XFEL/SPring 8, “SACLA,” has been constructed. In order to maintain a stable self-amplified spontaneous emission (SASE interaction, the straightness and overlap of the axes to within 3  μm between the electron beams and the radiated x rays for an undulator section of about 100 m length is necessary. This straightness means relative alignment to an experimental target sample. Furthermore, a temporal stability of 30 fs in order to maintain a constant peak beam current is also necessary to conduct stable SASE lasing. The monitor system was developed to satisfy these spatial and temporal stability and resolution criteria. The system comprises spatial monitors, such as cavity-type beam-position monitors and screen monitors, as well as temporal measurement instruments, such as current monitors, waveguide spectrometers, coherent synchrotron-radiation detectors, a streak camera, and an rf deflector. Commissioning of SACLA started from March 2011, and the monitors performed sufficient roles to tune the beams for lasing. The achieved overall performances of the system, including data acquisition, are: the beam position monitor has a spatial resolution of 600 nm in rms; the bunch-length monitors show ability to observe bunch lengths from 1 ns in an injector with velocity bunching to less than 30 fs after three-stage bunch compressors. The less than 3  μm spatial resolution of the screen monitor was also confirmed during practical beam operation. Owing to these fulfilled performances, such as the high spatial and temporal resolutions, stable lasing of SACLA has been achieved.

  5. MHz rate X-Ray imaging with GaAs:Cr sensors using the LPD detector system

    Science.gov (United States)

    Veale, M. C.; Booker, P.; Cline, B.; Coughlan, J.; Hart, M.; Nicholls, T.; Schneider, A.; Seller, P.; Pape, I.; Sawhney, K.; Lozinskaya, A. D.; Novikov, V. A.; Tolbanov, O. P.; Tyazhev, A.; Zarubin, A. N.

    2017-02-01

    The STFC Rutherford Appleton Laboratory (U.K.) and Tomsk State University (Russia) have been working together to develop and characterise detector systems based on chromium-compensated gallium arsenide (GaAs:Cr) semiconductor material for high frame rate X-ray imaging. Previous work has demonstrated the spectroscopic performance of the material and its resistance to damage induced by high fluxes of X-rays. In this paper, recent results from experiments at the Diamond Light Source Synchrotron have demonstrated X-ray imaging with GaAs:Cr sensors at a frame rate of 3.7 MHz using the Large Pixel Detector (LPD) ASIC, developed by STFC for the European XFEL. Measurements have been made using a monochromatic 20 keV X-ray beam delivered in a single hybrid pulse with an instantenous flux of up to ~ 1 × 1010 photons s-1 mm-2. The response of 500 μm GaAs:Cr sensors is compared to that of the standard 500 μm thick LPD Si sensors.

  6. Accuracy of cranial coplanar beam therapy using an oblique, stereoscopic x-ray image guidance system

    International Nuclear Information System (INIS)

    Vinci, Justin P.; Hogstrom, Kenneth R.; Neck, Daniel W.

    2008-01-01

    A system for measuring two-dimensional (2D) dose distributions in orthogonal anatomical planes in the cranium was developed and used to evaluate the accuracy of coplanar conformal therapy using ExacTrac image guidance. Dose distributions were measured in the axial, sagittal, and coronal planes using a CIRS (Computerized Imaging Reference Systems, Inc.) anthropomorphic head phantom with a custom internal film cassette. Sections of radiographic Kodak EDR2 film were cut, processed, and digitized using custom templates. Spatial and dosimetric accuracy and precision of the film system were assessed. BrainScan planned a coplanar-beam treatment to conformally irradiate a 2-cm-diameterx2-cm-long cylindrical planning target volume. Prior to delivery, phantom misalignments were imposed in combinations of ±8 mm offsets in each of the principal directions. ExacTrac x-ray correction was applied until the phantom was within an acceptance criteria of 1 mm/1 deg. (first two measurement sets) or 0.4 mm/0.4 deg. (last two measurement sets). Measured dose distributions from film were registered to the treatment plan dose calculations and compared. Alignment errors, displacement between midpoints of planned and measured 70% isodose contours (Δc), and positional errors of the 80% isodose line were evaluated using 49 2D film measurements (98 profiles). Comparison of common, but independent measurements of Δc showed that systematic errors in the measurement technique were 0.2 mm or less along all three anatomical axes and that random error averaged (σ±σ σ ) 0.29±0.06 mm for the acceptance criteria of 1 mm/1 deg. and 0.15±0.02 mm for the acceptance criteria of 0.4 mm/0.4 deg. . The latter was consistent with independent estimates that showed the precision of the measurement system was 0.3 mm (2σ). Values of Δc were as great as 0.9, 0.3, and 1.0 mm along the P-A, R-L, and I-S axes, respectively. Variations in Δc along the P-A axis were correlated to misalignments between laser

  7. Development of the focal plane PNCCD camera system for the X-ray space telescope eROSITA

    International Nuclear Information System (INIS)

    Meidinger, Norbert; Andritschke, Robert; Ebermayer, Stefanie; Elbs, Johannes; Haelker, Olaf; Hartmann, Robert; Herrmann, Sven; Kimmel, Nils; Schaechner, Gabriele; Schopper, Florian; Soltau, Heike; Strueder, Lothar; Weidenspointner, Georg

    2010-01-01

    A so-called PNCCD, a special type of CCD, was developed twenty years ago as focal plane detector for the XMM-Newton X-ray astronomy mission of the European Space Agency ESA. Based on this detector concept and taking into account the experience of almost ten years of operation in space, a new X-ray CCD type was designed by the 'MPI semiconductor laboratory' for an upcoming X-ray space telescope, called eROSITA (extended Roentgen survey with an imaging telescope array). This space telescope will be equipped with seven X-ray mirror systems of Wolter-I type and seven CCD cameras, placed in their foci. The instrumentation permits the exploration of the X-ray universe in the energy band from 0.3 up to 10 keV by spectroscopic measurements with a time resolution of 50 ms for a full image comprising 384x384 pixels. Main scientific goals are an all-sky survey and investigation of the mysterious 'Dark Energy'. The eROSITA space telescope, which is developed under the responsibility of the 'Max-Planck-Institute for extraterrestrial physics', is a scientific payload on the new Russian satellite 'Spectrum-Roentgen-Gamma' (SRG). The mission is already approved by the responsible Russian and German space agencies. After launch in 2012 the destination of the satellite is Lagrange point L2. The planned observational program takes about seven years. We describe the design of the eROSITA camera system and present important test results achieved recently with the eROSITA prototype PNCCD detector. This includes a comparison of the eROSITA detector with the XMM-Newton detector.

  8. X-ray cardiovascular examination apparatus

    International Nuclear Information System (INIS)

    1977-01-01

    An X-ray source is mounted in an enclosure for angulating longitudinally about a horizontal axis. An X-ray-permeable, patient-supporting table is mounted on the top of the enclosure for executing lateral and longitudinal movements. An X-ray image-receiving device such as an X-ray image intensifier is mounted above the table on a vertically movable arm which is on a longitudinally movable carriage. Electric control means are provided for angulating the X-ray source and image intensifier synchronously as the image intensifier system is shifted longitudinally or vertically such that the central ray from the X-ray source is kept intensifier

  9. Modelling of a total reflection X-ray fluorescence (TXRF) system ...

    African Journals Online (AJOL)

    The simulation of the different stages involved in x-ray fluorescence emissions was carried out by writing a suite of computer programs using FORTRAN programming language. These computer simulated XRF stages were then integrated together to generate a general robust model which was run with the digital visual ...

  10. High Pressure X-ray Absorption Studies on Correlated-Electron Systems

    International Nuclear Information System (INIS)

    Cornelius, Andrew L.

    2016-01-01

    This project used high pressure to alter the electron-electron and electron-lattice interactions in rare earth and actinide compounds. Knowledge of these properties is the starting points for a first-principles understanding of electronic and electronically related macroscopic properties. The research focused on a systematic study of x-ray absorption measurements on rare earth and actinide compounds.

  11. CHANDRA CHARACTERIZATION OF X-RAY EMISSION IN THE YOUNG F-STAR BINARY SYSTEM HD 113766

    Energy Technology Data Exchange (ETDEWEB)

    Lisse, C. M. [Planetary Exploration Branch, Space Exploration Sector, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States); Christian, D. J. [Department of Physics and Astronomy, California State University Northridge, 18111 Nordhoff Street, Northridge, CA 91330 (United States); Wolk, S. J. [Chandra X-ray Center, Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Günther, H. M. [Massachusetts Institute of Technology, Kavli Institute for Astrophysics and Space Research, 77 Massachusetts Avenue, NE83-569, Cambridge, MA 02139 (United States); Chen, C. H. [STScI, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Grady, C. A., E-mail: carey.lisse@jhuapl.edu, E-mail: damian.christian@csun.edu, E-mail: swolk@cfa.harvard.edu, E-mail: hgunther@mit.edu, E-mail: cchen@stsci.edu, E-mail: carol.a.grady@nasa.gov [Eureka Scientific and Goddard Space Flight Center, Code 667, NASA-GSFC, Greenbelt, MD 20771 (United States)

    2017-02-01

    Using Chandra , we have obtained imaging X-ray spectroscopy of the 10–16 Myr old F-star binary HD 113766. We individually resolve the 1.″4 separation binary components for the first time in the X-ray and find a total 0.3–2.0 keV luminosity of 2.2 × 10{sup 29} erg s{sup −1}, consistent with previous RASS estimates. We find emission from the easternmost, infrared-bright, dusty member HD 113766A to be only ∼10% that of the western, infrared-faint member HD 113766B. There is no evidence for a 3rd late-type stellar or substellar member of HD 113766 with L {sub x} > 6 × 10{sup 25} erg s{sup −1} within 2′ of the binary pair. The ratio of the two stars’ X-ray luminosity is consistent with their assignments as F2V and F6V by Pecaut et al. The emission is soft for both stars, kT {sub Apec} = 0.30–0.50 keV, suggesting X-rays produced by stellar rotation and/or convection in young dynamos, but not accretion or outflow shocks, which we rule out. A possible 2.8 ± 0.15 (2 σ ) hr modulation in the HD 113766B X-ray emission is seen, but at very low confidence and of unknown provenance. Stellar wind drag models corresponding to L {sub x} ∼ 2 × 10{sup 29} erg s{sup −1} argue for a 1 mm dust particle lifetime around HD 113766B of only ∼90,0000 years, suggesting that dust around HD 113766B is quickly removed, whereas 1 mm sized dust around HD 113766A can survive for >1.5 × 10{sup 6} years. At 10{sup 28}–10{sup 29} erg s{sup −1} X-ray luminosity, astrobiologically important effects, like dust warming and X-ray photolytic organic synthesis, are likely for any circumstellar material in the HD 113766 systems.

  12. CHANDRA CHARACTERIZATION OF X-RAY EMISSION IN THE YOUNG F-STAR BINARY SYSTEM HD 113766

    International Nuclear Information System (INIS)

    Lisse, C. M.; Christian, D. J.; Wolk, S. J.; Günther, H. M.; Chen, C. H.; Grady, C. A.

    2017-01-01

    Using Chandra , we have obtained imaging X-ray spectroscopy of the 10–16 Myr old F-star binary HD 113766. We individually resolve the 1.″4 separation binary components for the first time in the X-ray and find a total 0.3–2.0 keV luminosity of 2.2 × 10 29 erg s −1 , consistent with previous RASS estimates. We find emission from the easternmost, infrared-bright, dusty member HD 113766A to be only ∼10% that of the western, infrared-faint member HD 113766B. There is no evidence for a 3rd late-type stellar or substellar member of HD 113766 with L x  > 6 × 10 25 erg s −1 within 2′ of the binary pair. The ratio of the two stars’ X-ray luminosity is consistent with their assignments as F2V and F6V by Pecaut et al. The emission is soft for both stars, kT Apec  = 0.30–0.50 keV, suggesting X-rays produced by stellar rotation and/or convection in young dynamos, but not accretion or outflow shocks, which we rule out. A possible 2.8 ± 0.15 (2 σ ) hr modulation in the HD 113766B X-ray emission is seen, but at very low confidence and of unknown provenance. Stellar wind drag models corresponding to L x  ∼ 2 × 10 29 erg s −1 argue for a 1 mm dust particle lifetime around HD 113766B of only ∼90,0000 years, suggesting that dust around HD 113766B is quickly removed, whereas 1 mm sized dust around HD 113766A can survive for >1.5 × 10 6 years. At 10 28 –10 29 erg s −1 X-ray luminosity, astrobiologically important effects, like dust warming and X-ray photolytic organic synthesis, are likely for any circumstellar material in the HD 113766 systems.

  13. Fast X-ray detection systems based on GaAs diodes grown by LPE

    International Nuclear Information System (INIS)

    Rente, C.; Lauter, J.; Apetz, R.; Lueth, H.

    1996-01-01

    We report on the fabrication and characterization of GaAs based X-ray detectors. The detector structures are grown by liquid phase epitaxy (LPE) and show typical background doping in the order of 10 14 cm -3 (n-type) so that active regions up to 43 μm could be realized. Schottky diodes were processed with active areas up to 1mm 2 . Typical dark current densities are as low as 360pA/mm 2 at 100V. The energy resolution of the detector in combination with a charge sensitive preamplifier was determined to be 1.6keV (FWHM) for x-rays with an energy between 6 and 60keV. The time response of the devices coupled to a fast transimpedance amplifier with a bandwidth of 100MHz was investigated. Single photon detection at room temperature was achieved for X-rays having energies of 14 keV and higher. The measured time resolutions were 600ps (FWHM=1.4ns) and 430ps (FWHM=1.0ns) for X-ray photons of 14.4keV and 21.5keV, respectively. The efficiency of the detector having a 43μm thick depleted layer was determined to be 70% at 14.4 keV and 40% at 21.5keV. These detectors open a new field of X-ray spectroscopy especially for high rate applications and timing measurements at synchrotron radiation facilities

  14. Miniature x-ray point source for alignment and calibration of x-ray optics

    International Nuclear Information System (INIS)

    Price, R.H.; Boyle, M.J.; Glaros, S.S.

    1977-01-01

    A miniature x-ray point source of high brightness similar to that of Rovinsky, et al. is described. One version of the x-ray source is used to align the x-ray optics on the Argus and Shiva laser systems. A second version is used to determine the spatial and spectral transmission functions of the x-ray optics. The spatial and spectral characteristics of the x-ray emission from the x-ray point source are described. The physical constraints including size, intensity and thermal limitations, and useful lifetime are discussed. The alignment and calibration techniques for various x-ray optics and detector combinations are described

  15. X ray absorption fine structure of systems in the anharmonic limit

    Science.gov (United States)

    Mustredeleon, J.; Conradson, S. D.; Batistic, I.; Bishop, A. R.; Raistrick, I.; Jackson, W. E.; Brown, G. E.

    A new approach to the analysis of x-ray absorption fine structure (XAFS) data is presented. It is based on the use of radial distribution functions directly calculated from a single-particle ion Hamiltonian containing model potentials. The starting point of this approach is the statistical average of the XAFS for an atomic pair. This average can be computed using a radial distribution function (RDF), which can be expressed in terms of the eigenvalues and wavefunctions associated with the model potential. The pair potential describing the ionic motion is then expressed in terms of parameters that are determined by fitting this statistical average to the experimental XAFS spectrum. This approach allows the use of XAFS as a tool for mapping near-neighbor interatomic potentials, and allows the treatment of systems which exhibit strongly anharmonic potentials which can be treated by perturbative methods. Using this method we have analyzed the high temperature behavior of the oxygen contributions to the Fe K-edge XAFS in the ferrosilicate minerals andradite (Ca3Fe2Si3O12) and magnesiowustite (Mg(0.9)Fe(0.1)O). Using a temperature dependent anharmonic correction derived from these model compounds, we have found evidence for a local structural change in the Fe-O coordination environment upon melting of the geologically important mineral fayalite (Fe2SiO4). We have also employed this method to the study of the axial oxygen contributions to the polarized Cu K-edge XAFS on oriented samples of YBa2Cu3O7 and related compounds. From this study we find evidence for an axial oxygen-centered lattice distortion accompanying the superconducting phase transition and a correlation between this distortion and Tc. The relation of the observed lattice distortion to mechanisms of superconductivity is discussed.

  16. X-ray absorption fine structure of systems in the anharmonic limit

    International Nuclear Information System (INIS)

    Mustre de Leon, J.; Conradson, S.D.; Batistic, I.; Bishop, A.R.; Raistrick, I.; Jackson, W.E.; Brown, G.E.

    1991-01-01

    A new approach to the analysis of x-ray absorption fine structure (XAFS) data is presented. It is based on the use of radial distribution functions directly calculated from a single-particle ion hamiltonian containing model potentials. The starting point of this approach is the statistical average of the XAFS for an atomic pair. This average can be computed using a radial distribution function (RDF), which can be expressed in terms of the eigenvalues and wavefunctions associated with the model potential. The pair potential describing the ionic motion is then expressed in terms of parameters that are determined by fitting this statistical average to the experimental XAFS spectrum. This approach allow the use of XAFS as a tool for mapping near-neighbor interatomic potentials, and allows the treatment of systems which exhibit strongly anharmonic potentials which can be treated by perturbative methods. Using this method we have analyzed the high temperature behavior of the oxygen contributions to the Fe K-edge XAFS in the ferrosilicate minerals andradite (Ca 3 Fe 2 Si 3 O 12 ) and magnesiowustite (Mg 0.9 Fe 0.1 O). Using a temperature dependent anharmonic correction derived from these model compounds, we have found evidence for a local structural change in the Fe-O coordination environment upon melting of the geologically important mineral fayalite (Fe 2 SiO 4 ). We have also employed this method to the study of the axial oxygen contributions to the polarized Cu K-edge XAFS on oriented samples of YBa 2 Cu 3 O 7 and related compounds. From this study we find evidence for an axial oxygen-centered lattice distortion accompanying the superconducting phase transition and a correlation between this distortion and T c . The relation of the observed lattice distortion to mechanisms of superconductivity is discussed. 33 refs., 6 figs

  17. Soft x-ray Planetary Imager

    Data.gov (United States)

    National Aeronautics and Space Administration — The project is to prototype a soft X-ray Imager for planetary applications that has the sensitivity to observe solar system sources of soft  X-ray emission. A strong...

  18. X-ray microtomography

    International Nuclear Information System (INIS)

    Dunsmuir, J.H.; Ferguson, S.R.; D'Amico, K.L.; Stokes, J.P.

    1991-01-01

    In this paper the authors describe the application of a new high-resolution X-ray tomographic microscope to the study of porous media. The microscope was designed to exploit the properties of a synchrotron X-ray source to perform three dimensional tomography on millimeter sized objects with micron resolution and has been used in materials science studies with both synchrotron and conventional and synchrotron sources will be compared. In this work the authors have applied the microscope to measure the three dimensional structure of fused bead packs and berea sandstones with micron resolution and have performed preliminary studies of flow in these media with the microscope operated in a digital subtraction radiography mode. Computer graphics techniques have been applied to the data to visually display the structure of the pore body system. Tomographic imaging after flow experiments should detect the structure of the oil-water interface in the pore network and this work is ongoing

  19. Pressurized subsampling system for pressured gas-hydrate-bearing sediment: Microscale imaging using X-ray computed tomography

    International Nuclear Information System (INIS)

    Jin, Yusuke; Konno, Yoshihiro; Nagao, Jiro

    2014-01-01

    A pressurized subsampling system was developed for pressured gas hydrate (GH)-bearing sediments, which have been stored under pressure. The system subsamples small amounts of GH sediments from cores (approximately 50 mm in diameter and 300 mm in height) without pressure release to atmospheric conditions. The maximum size of the subsamples is 12.5 mm in diameter and 20 mm in height. Moreover, our system transfers the subsample into a pressure vessel, and seals the pressure vessel by screwing in a plug under hydraulic pressure conditions. In this study, we demonstrated pressurized subsampling from artificial xenon-hydrate sediments and nondestructive microscale imaging of the subsample, using a microfocus X-ray computed tomography (CT) system. In addition, we estimated porosity and hydrate saturation from two-dimensional X-ray CT images of the subsamples

  20. Characterizing the X-ray & Stellar Wind Environment in the ~1 Gyr Late Heavy Bombardment System Eta Corvi

    Science.gov (United States)

    Lisse, Carey

    2012-09-01

    We propose a 40 ksec ACIS-S observation of the 1 Gyr old system Eta Corvi, the site of an on-going Late Heavy Bombardment (Lisse et al. 2012), in order to determine the spectrum of x-ray radiation in the burgeoning system, its origin in the stellar coronae and circumstellar debris belts, and its impact on the water and organics recently delivered to a rocky planet in the terrestrial habitability zone.

  1. Geometric calibration of a stationary digital breast tomosynthesis system based on distributed carbon nanotube X-ray source arrays.

    Directory of Open Access Journals (Sweden)

    Changhui Jiang

    Full Text Available Stationary digital breast tomosynthesis (sDBT with distributed X-ray sources based on carbon nanotube (CNT field emission cathodes has been recently proposed as an approach that can prevent motion blur produced by traditional DBT systems. In this paper, we simulate a geometric calibration method based on a proposed multi-source CNT X-ray sDBT system. This method is a projection matrix-based approach with seven geometric parameters, all of which can be obtained from only one projection datum of the phantom. To our knowledge, this study reports the first application of this approach in a CNT-based multi-beam X-ray sDBT system. The simulation results showed that the extracted geometric parameters from the calculated projection matrix are extremely close to the input values and that the proposed method is effective and reliable for a square sDBT system. In addition, a traditional cone-beam computed tomography (CT system was also simulated, and the uncalibrated and calibrated geometric parameters were used in image reconstruction based on the filtered back-projection (FBP method. The results indicated that the images reconstructed with calibrated geometric parameters have fewer artifacts and are closer to the reference image. All the simulation tests showed that this geometric calibration method is optimized for sDBT systems but can also be applied to other application-specific CT imaging systems.

  2. Geometric calibration of a stationary digital breast tomosynthesis system based on distributed carbon nanotube X-ray source arrays.

    Science.gov (United States)

    Jiang, Changhui; Zhang, Na; Gao, Juan; Hu, Zhanli

    2017-01-01

    Stationary digital breast tomosynthesis (sDBT) with distributed X-ray sources based on carbon nanotube (CNT) field emission cathodes has been recently proposed as an approach that can prevent motion blur produced by traditional DBT systems. In this paper, we simulate a geometric calibration method based on a proposed multi-source CNT X-ray sDBT system. This method is a projection matrix-based approach with seven geometric parameters, all of which can be obtained from only one projection datum of the phantom. To our knowledge, this study reports the first application of this approach in a CNT-based multi-beam X-ray sDBT system. The simulation results showed that the extracted geometric parameters from the calculated projection matrix are extremely close to the input values and that the proposed method is effective and reliable for a square sDBT system. In addition, a traditional cone-beam computed tomography (CT) system was also simulated, and the uncalibrated and calibrated geometric parameters were used in image reconstruction based on the filtered back-projection (FBP) method. The results indicated that the images reconstructed with calibrated geometric parameters have fewer artifacts and are closer to the reference image. All the simulation tests showed that this geometric calibration method is optimized for sDBT systems but can also be applied to other application-specific CT imaging systems.

  3. X-ray radiotherapy

    International Nuclear Information System (INIS)

    Tronc, D.

    1995-01-01

    Full text: The most common form of radio therapy is X-ray therapy, where a beam of photons or their parent electrons break down hydrogen bonds within the body's cells and remove certain DNA information necessary for cell multiplication. This process can eradicate malignant cells leading to complete recovery, to the remission of some cancers, or at least to a degree of pain relief. The radiotherapy instrument is usually an electron linac, and the electrons are used either directly in 'electrotherapy' for some 10% of patients, or the electrons bombard a conversion target creating a broad beam of high energy photons or 'penetration X-rays'. The simplest machine consists of several accelerating sections at around 3 GHz, accelerating electrons to 6 MeV; a cooled tungsten target is used to produce a 4 Gray/min X-ray field which can be collimated into a rectangular shape at the patient position. This tiny linac is mounted inside a rotating isocentric gantry above the patient who must remain perfectly still. Several convergent beams can also be used to increase the delivered dose. More sophisticated accelerators operate at up to 18 MeV to increase penetration depths and decrease skin exposure. Alternatively, electrotherapy can be used with different energies for lower and variable penetration depths - approximately 0.5 cm per MeV. In this way surface tissue may be treated without affecting deeper and more critical anatomical regions. This type of linac, 1 to 2 metres long, is mounted parallel to the patient with a bending magnet to direct the beam to the radiotherapy system, which includes the target, thick movable collimator jaws, a beam field equalizer, dose rate and optical field simulation and energy controls. There are over 2000 acceleratorbased X-ray treatment units worldwide. Western countries have up to two units per million population, whereas in developing countries such as Bangladesh, the density is only one per 100 million. Several

  4. First use of a truly-hybrid x-ray/MR imaging system for guidance of brain biopsy

    International Nuclear Information System (INIS)

    Fahrig, R.; Daniel, B.L.; Butts, K.; Pelc, N.J.; Heit, G.; Wen, Z.

    2003-01-01

    The use of a new hybrid imaging system for guidance of a brain biopsy is described. The system combines the strengths of MRI (soft-tissue contrast, arbitrary plane selection) with those of x-ray fluoroscopy (high-resolution real-time projection images, clear portrayal of bony structures) and allows switching between the imaging modalities without moving the patient. The biopsy was carried out using x-ray guidance for direction of the needle through the foramen ovale and MR guidance to target the soft-tissue lesion. Appropriate samples were acquired. The system could be particularly effective for guidance of those cases where motion, swelling, resection and other intra-operative anatomical changes cannot be accounted for using traditional stereotactic-based imaging approaches. (author)

  5. Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applications

    DEFF Research Database (Denmark)

    Hiller, Jochen; Maisl, Michael; Reindl, Leonard M

    2012-01-01

    This paper presents physical and metrological characterization measurements conducted for an industrial x-ray micro-computed tomography (CT) system. As is well known in CT metrology, many factors, e.g., in the scanning and reconstruction process, the image processing, and the 3D data evaluation...... components of a CT scanner, i.e. the x-ray tube and the flat-panel detector, are characterized. The contrast and noise transfer property of the scanner is obtained using image-processing methods based on linear systems theory. A long-term temperature measurement in the scanner cabinet has been carried out....... The dimensional measurement property has been quantified by using a calibrated ball-bar and uncertainty budgeting. Information about the performance of a CT scanner system in terms of contrast and noise transmission and sources of geometrical errors will help plan CT scans more efficiently. In particular...

  6. LabVIEW interface with Tango control system for a multi-technique X-ray spectrometry IAEA beamline end-station at Elettra Sincrotrone Trieste

    Energy Technology Data Exchange (ETDEWEB)

    Wrobel, P.M. [Physics Section, Nuclear Science and Instrumentation Laboratory (NSIL), IAEA Laboratories, A-2444 Seibersdorf (Austria); AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, al. A. Mickiewicza 30, 30-059 Krakow (Poland); Bogovac, M. [Physics Section, Nuclear Science and Instrumentation Laboratory (NSIL), IAEA Laboratories, A-2444 Seibersdorf (Austria); Sghaier, H. [Physics Section, Nuclear Science and Instrumentation Laboratory (NSIL), IAEA Laboratories, A-2444 Seibersdorf (Austria); Institut Superieur d’Informatique et de Mathematiques de Monastir (ISIMM), Departement de technologie, 5000 Monastir (Tunisia); Leani, J.J. [Physics Section, Nuclear Science and Instrumentation Laboratory (NSIL), IAEA Laboratories, A-2444 Seibersdorf (Austria); IFEG – CONICET, Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina); Migliori, A.; Padilla-Alvarez, R. [Physics Section, Nuclear Science and Instrumentation Laboratory (NSIL), IAEA Laboratories, A-2444 Seibersdorf (Austria); Czyzycki, M. [Physics Section, Nuclear Science and Instrumentation Laboratory (NSIL), IAEA Laboratories, A-2444 Seibersdorf (Austria); AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, al. A. Mickiewicza 30, 30-059 Krakow (Poland); Osan, J. [Physics Section, Nuclear Science and Instrumentation Laboratory (NSIL), IAEA Laboratories, A-2444 Seibersdorf (Austria); Environmental Physics Department, Hungarian Academy of Sciences Centre for Energy Research, Konkoly-Thege M. út 29-33., H-1121 Budapest (Hungary); Kaiser, R.B. [Physics Section, Nuclear Science and Instrumentation Laboratory (NSIL), IAEA Laboratories, A-2444 Seibersdorf (Austria); and others

    2016-10-11

    A new synchrotron beamline end-station for multipurpose X-ray spectrometry applications has been recently commissioned and it is currently accessible by end-users at the XRF beamline of Elettra Sincrotrone Trieste. The end-station consists of an ultra-high vacuum chamber that includes as main instrument a seven-axis motorized manipulator for sample and detectors positioning, different kinds of X-ray detectors and optical cameras. The beamline end-station allows performing measurements in different X-ray spectrometry techniques such as Microscopic X-Ray Fluorescence analysis (µXRF), Total Reflection X-Ray Fluorescence analysis (TXRF), Grazing Incidence/Exit X-Ray Fluorescence analysis (GI-XRF/GE-XRF), X-Ray Reflectometry (XRR), and X-Ray Absorption Spectroscopy (XAS). A LabVIEW Graphical User Interface (GUI) bound with Tango control system consisted of many custom made software modules is utilized as a user-friendly tool for control of the entire end-station hardware components. The present work describes this advanced Tango and LabVIEW software platform that utilizes in an optimal synergistic manner the merits and functionality of these well-established programming and equipment control tools. - Highlights: • A new methodology for control of a synchrotron beamline end-station is shown. • The new control system comprises a novel binding of Tango control system with LabVIEW interface. • The reliability of the control system is demonstrated by examples of analytical applications.

  7. Combination use of lentinan with x-ray therapy in mouse experimental tumor system, (2)

    International Nuclear Information System (INIS)

    Shiio, Tsuyoshi; Ohishi, Kazuo; Tsuchiya, Yoshiharu; Niitsu, Iwayasu; Hayashibara, Hiromi; Yoshihama, Takashi; Moriyuki, Hirobumi

    1988-01-01

    C3H/He mice transplanted syngeneic MM102 tumor subcutaneously in the footpad were used to study the timing of administration of lentinan when combined with local irradiation of X-ray. In combination with 1,000 rads irradiation, the administration of lentinan after X-ray was not effective. When lentinan was administered in combination with 2,000 to 3,000 rads irradiation, the growth of tumor was decreased significantly in comparison with the groups which received radiotherapy alone and those that received lentinan alone. The administration of lentinan before irradiation was effective at the same degree in the group that received lentinan after irradiation. Life prolongation effect was also observed in the group that received lentinan before and after irradiation, and 4 mice among 8 tested mice were survived at 70th day after tumor transplantation. (author)

  8. Possible mechanism for mass transfer in X-ray binary systems with OB supergiant companions

    International Nuclear Information System (INIS)

    Alme, M.L.; Wilson, J.R.

    1976-01-01

    We have studied the ''beginning Roche lobe overflow'' phase of mass transfer. We find that before the primary fills its Roche lobe, radiation-driven density waves generated in the atmosphere produce a sufficient mass outflow rate to power a compact X-ray source. In particular, for a model of Cygnus X-1, if the radius of the photosphere is between 82 and 86 percent of the radius of the Roche equipotential, large-amplitude density waves with irregular periods of a few days are observed. These density waves, which are generated by radiation pressure effects, pass through the inner Lagrangian point with velocities approx.100 km s -1 , and can easily provide sufficient material to power the compact X-ray source

  9. New medical imaging systems exploiting the energy dispersive X-ray diffraction with spectrometric CdZnTe based detector

    International Nuclear Information System (INIS)

    Barbes, Damien

    2016-01-01

    This thesis studies the interest of measuring the coherent scattering of X-rays for breast diagnosis imaging. Nowadays, most of X-ray-based medical imaging techniques use the information of X-rays attenuation through the tissues. It is the case for mammography, the most common breast imaging modality. The recent emergence of energy resolved detectors (based on semiconductors in particular) allows to consider using another phenomenon: the coherent X-ray scattering. Measurement of diffracted spectra can provide new information related to the molecular structure of the examined tissues, in order to improve their characterization and therefore improve the final diagnosis. Two modalities are considered: the breast cancer detection in vivo, following a suspicious mammography result, or biopsy analysis. The coherent scattering measurement system developed during this thesis work uses energy-resolved CdZnTe-based detectors, these detectors combining performances (energy resolution, sensitivity, spatial resolution, and compactness) promising for clinical application. This system is also based on the detector pixelation, which allows to provide an imaging modality capable of characterizing analyzed materials or tissues in one direction without any translation or rotation. A complete study of the measurement system is proposed in this thesis, structured in three main parts: modeling and simulation of the system, development of the processing of the data measured by the detector in order to image and characterize the analyzed sample and finally, designing of a new and more complex experimental setup based on a whole detector and multi-slit collimation system. An experimental validation is proposed for each of these three parts. (author) [fr

  10. A portable high-field pulsed-magnet system for single-crystal x-ray scattering studies

    International Nuclear Information System (INIS)

    Islam, Zahirul; Lang, Jonathan C.; Ruff, Jacob P. C.; Ross, Kathryn A.; Gaulin, Bruce D.; Nojiri, Hiroyuki; Matsuda, Yasuhiro H.; Qu Zhe

    2009-01-01

    We present a portable pulsed-magnet system for x-ray studies of materials in high magnetic fields (up to 30 T). The apparatus consists of a split-pair of minicoils cooled on a closed-cycle cryostat, which is used for x-ray diffraction studies with applied field normal to the scattering plane. A second independent closed-cycle cryostat is used for cooling the sample to near liquid helium temperatures. Pulsed magnetic fields (∼1 ms in total duration) are generated by discharging a configurable capacitor bank into the magnet coils. Time-resolved scattering data are collected using a combination of a fast single-photon counting detector, a multichannel scaler, and a high-resolution digital storage oscilloscope. The capabilities of this instrument are used to study a geometrically frustrated system revealing strong magnetostrictive effects in the spin-liquid state.

  11. Characteristics of the neutron and X-ray tomography system at the SANRAD facility in South Africa

    International Nuclear Information System (INIS)

    Beer, F.C. de

    2005-01-01

    Through collaboration with the NEUTRA-facility at the Paul Scherrer Institute (PSI), Switzerland, a turnkey tomography system was designed specifically for the beam geometry at the South African Neutron Radiography (SANRAD) facility, located on the beam port floor of the SAFARI-1 nuclear research reactor and operated by Necsa. The new system is currently being extensively utilized in both 2D and 3D mode for various applications in general industry and institutional activities. The basic performance characteristics of its 3D tomography capability in a neutron and X-ray configuration are presented with the aid of several case studies. An X-ray source has also been commissioned to further diversify the capabilities of the facility

  12. High-resolution inelastic X-ray scattering to study the high-frequency atomic dynamics of disordered systems

    International Nuclear Information System (INIS)

    Monaco, G.

    2008-01-01

    The use of momentum-resolved inelastic X-ray scattering with meV energy resolution to study the high-frequency atomic dynamics in disordered systems is here reviewed. The typical realization of this experiment is described together with some common models used to interpret the measured spectra and to extract parameters of interest for the investigation of disordered systems. With the help of some selected examples, the present status of the field is discussed. Particular attention is given to those results which are still open for discussion or controversial, and which will require further development of the technique to be fully solved. Such an instrumental development seems nowadays possible at the light of recently proposed schemes for advanced inelastic X-ray scattering spectrometers. (author)

  13. Comparison of simulated light sensitometer and x-ray sensitometer for screen-film system in medical radiology

    International Nuclear Information System (INIS)

    Tsuyama, Yasuko; Yamamoto, Yoshinori.

    1983-01-01

    Sensitometric techniques are used for determining the characteristic curve in medical imaging. In this study intensity-scale (inverse square law, simulated light) methods are used in the determination of radiographic screen-film system characteristic curve. Films which were exposed to simulated light and x-ray were processed in the same automatic processor simultaneously. These curves were overlapped at Net density of 1.0 to compare the curve shapes. The results show there is a good correlation between the density of x-ray sensitometry and that of simulated light sensitometry. The differences of density are within +- 0.12 (+- 10 % log exposure). This applies to both blue sensitive and green sensitive systems. (author)

  14. Rapid phenotyping of crop root systems in undisturbed field soils using X-ray computed tomography.

    Science.gov (United States)

    Pfeifer, Johannes; Kirchgessner, Norbert; Colombi, Tino; Walter, Achim

    2015-01-01

    X-ray computed tomography (CT) has become a powerful tool for root phenotyping. Compared to rather classical, destructive methods, CT encompasses various advantages. In pot experiments the growth and development of the same individual root can be followed over time and in addition the unaltered configuration of the 3D root system architecture (RSA) interacting with a real field soil matrix can be studied. Yet, the throughput, which is essential for a more widespread application of CT for basic research or breeding programs, suffers from the bottleneck of rapid and standardized segmentation methods to extract root structures. Using available methods, root segmentation is done to a large extent manually, as it requires a lot of interactive parameter optimization and interpretation and therefore needs a lot of time. Based on commercially available software, this paper presents a protocol that is faster, more standardized and more versatile compared to existing segmentation methods, particularly if used to analyse field samples collected in situ. To the knowledge of the authors this is the first study approaching to develop a comprehensive segmentation method suitable for comparatively large columns sampled in situ which contain complex, not necessarily connected root systems from multiple plants grown in undisturbed field soil. Root systems from several crops were sampled in situ and CT-volumes determined with the presented method were compared to root dry matter of washed root samples. A highly significant (P < 0.01) and strong correlation (R(2) = 0.84) was found, demonstrating the value of the presented method in the context of field research. Subsequent to segmentation, a method for the measurement of root thickness distribution has been used. Root thickness is a central RSA trait for various physiological research questions such as root growth in compacted soil or under oxygen deficient soil conditions, but hardly assessable in high throughput until today, due

  15. Some imaging characteristics of the dynamic spatial reconstructor X-ray scanner system

    International Nuclear Information System (INIS)

    Behrenbeck, T.; Sinak, L.J.; Robb, R.A.; Kinsey, J.H.; Ritman, E.L.

    1984-01-01

    In late 1979, the Dynamic Spatial Reconstructor (DSR), a multiple X-ray source, stop action, volume scanning imaging device was installed. At present, the operational characteristics and biomedical utility of the DSR are being evaluated. This research project involves scanning experimental animals and carefully selected patients with cardiovascular and pulmonary pathology. The DSR scanner utilizes a computerized transaxial tomography principle to generate images of transverse slices of the body. (Auth.)

  16. Design of soft-X-ray tomographic system in WEST using GEM detectors

    Czech Academy of Sciences Publication Activity Database

    Mazon, D.; Chernyshova, M.; Jiolat, G.; Czarski, T.; Malard, P.; Kowalska-Strzeciwilk, E.; Jablonski, S.; Figacz, W.; Zagorski, R.; Kubkowska, M.; Kasprowicz, G.; Pozniak, K.; Zabolotny, W.; Larroque, S.; Verger, J.-M.; O’Mullane, M.; Mlynář, Jan; Byszuk, A.; Wojenski, A.

    96-97, October (2015), s. 856-860 ISSN 0920-3796. [Symposium on Fusion Technology 2014(SOFT-28)/28./. San Sebastián, 29.09.2014-03.10.2014] Institutional support: RVO:61389021 Keywords : Soft-X-ray * Gas detector * Tomography * WEST * Tokamak Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 1.301, year: 2015 http://www.sciencedirect.com/science/article/pii/S0920379615002215

  17. X-Ray Assembler Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — Federal regulations require that an assembler who installs one or more certified components of a diagnostic x-ray system submit a report of assembly. This database...

  18. Performance Test of the Next Generation X-Ray Beam Position Monitor System for The APS Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Yang, B.; Lee, S.; Westferro, F.; Jaski, Y.; Lenkszus, F.; Sereno, N.; Ramanathan, M.

    2017-03-25

    The Advanced Photon Source is developing its next major upgrade (APS-U) based on the multi-bend achromat lattice. Improved beam stability is critical for the upgrade and will require keeping short-time beam angle change below 0.25 µrad and long-term angle drift below 0.6 µrad. A reliable white x-ray beam diagnostic system in the front end will be a key part of the planned beam stabilization system. This system includes an x-ray beam position monitor (XBPM) based on x-ray fluorescence (XRF) from two specially designed GlidCop A-15 absorbers, a second XBPM using XRF photons from the Exit Mask, and two white beam intensity monitors using XRF from the photon shutter and Compton-scattered photons from the front end beryllium window or a retractable diamond film in windowless front ends. We present orbit stability data for the first XBPM used in the feedback control during user operations, as well as test data from the second XBPM and the intensity monitors. They demonstrate that the XBPM system meets APS-U beam stability requirements.

  19. X-ray diffraction studies of Pompeian wall paintings using synchrotron radiation and dedicated laboratory made systems

    International Nuclear Information System (INIS)

    Duran, A.; Castaing, J.; Walter, P.

    2010-01-01

    The full identification of artwork materials requires not only elemental analysis but also structural information of the compounds as provided by X-ray diffraction (XRD). This is easily done when taking samples (or micro-samples) from artworks. However, there is an increasing interest in performing non-destructive studies that require adapted XRD systems. Comparative study of synchrotron high-resolution X-ray powder diffraction (SR-HRPD) and laboratory non-destructive systems (portable XRD and micro-XRD) is the main objective of this work. There are no qualitative differences among the three systems as for detected phases in the Pompeian wall paintings that were studied, except in the case of minority phases which only were detected by SR-HRPD. The identified pigments were goethite, hematite, cinnabar, glauconite, Pompeian blue, together with calcite, dolomite and aragonite. Synchrotron XRD diagrams show better resolution than the others. In general, the peak widths in the diagrams obtained with the portable XRD system are similar to those obtained by micro-diffraction equipment. Factors such as residual divergence of X-ray sources, incidence angle and slit or collimator size are discussed in relation with the quality of XRD diagrams. (orig.)

  20. A study on development of guideline on writing technical document for electrical medical devices: Bone absorptiometric X-ray system

    International Nuclear Information System (INIS)

    Lee, Sung Youl; Kim, Jae Ryang; Kim, Eun Rim; Lee, Jun Ho; Lee, Chang Hyung; Park, Chang Won

    2016-01-01

    The market size of the bone absorptiometric X-ray system and the number of its approval by Ministry of Food and Drug Safety (MFDS) has annually increased, with a trend of increasing aging population and osteoporosis patients. For approval of manufactured or imported medical devices in Republic of Korea, it is required to submit its technical document. Therefore, it is need to develop the technical document guideline for the bone absorptiometric X-ray system for manufacturers, importers and reviewers. First of all, the technical documents which were already approved were examined and analyzed through MFDS approval administration system. Second, safety and performance test standards and methods that match international standards were drawn after conducting survey of the market status and the technology development trend for it, with examination and analysis of applicable domestic and overseas standards. Third, by operating industry-research-government cooperation, the guideline draft on writing technical document for the bone absorptiometric X-ray system was discussed, collecting their opinion. As a result, it is suitable to international and domestic condition, includes test evaluation methods and offer various information with appropriate examples to civil petitioner, when they write the technical documents