WorldWideScience

Sample records for ir dispenser percussion

  1. World Percussion Approaches in Collegiate Percussion Programs: A Mixed-Methods Study

    Science.gov (United States)

    Hernly, Patrick

    2012-01-01

    As world percussion has grown in popularity in American colleges and universities, two main problems have emerged. The first problem is that no known source exists detailing how percussion instructors have incorporated world percussion into their collegiate teaching. A review of the literature has highlighted four main approaches to incorporating…

  2. Impact Dynamics of a Percussive System Based on Rotary-Percussive Ultrasonic Drill

    Directory of Open Access Journals (Sweden)

    Yinchao Wang

    2017-01-01

    Full Text Available This paper presents an impact dynamic analysis of a percussive system based on rotary-percussive ultrasonic drill (RPUD. The RPUD employs vibrations on two sides of one single piezoelectric stack to achieve rotary-percussive motion, which improves drilling efficiency. The RPUD’s percussive system is composed of a percussive horn, a free mass, and a drill tool. The percussive horn enlarges longitudinal vibration from piezoelectric stack and delivers the vibration to the drill tool through the free mass, which forms the percussive motion. Based on the theory of conservation of momentum and Newton’s impact law, collision process of the percussive system under no-load condition is analyzed to establish the collision model between the percussive horn, the free mass, and the drill tool. The collision model shows that free mass transfers high-frequency small-amplitude vibration of percussive horn into low-frequency large-amplitude vibration of drill tool through impact. As an important parameter of free mass, the greater the weight of the free mass, the higher the kinetic energy obtained by drill tool after collision. High-speed camera system and drilling experiments are employed to validate the inference results of collision model by using a prototype of the RPUD.

  3. High-Frequency Percussive Ventilation Revisited

    Science.gov (United States)

    2010-01-01

    be implemented. ‡ Follow the reverse of the ventilation sequence if respiratory alkalosis develops—however, start at ventilation goal sequence 1 not at...High-frequency percussive ventilation (HFPV) has demonstrated a potential role as a rescue option for refractory acute respiratory distress syndrome...frequency percussive ventilation (HFPV) has demon- strated a potential role as a salvage option for refrac- tory acute respiratory distress syndrome

  4. Advanced Medication Dispenser

    Directory of Open Access Journals (Sweden)

    A.I. Alexan

    2013-12-01

    Full Text Available Medication dispensing is an important activity that can have major implications if done improperly. Dispensing must be done in the correct time interval, at the correct user, with the correct drug and dose. We propose a smart medication dispenser that can satisfy these needs and provide a mechanism for supervision. In order to ensure that the dispensing process is error free, the concept of a new smart medication container is used. A smart medication container is “smart” as it holds the medication dispensing parameters for the drugs it contains: dispensing time and date and name. Based on this information, the actual dispensing is done.

  5. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Methods: A qualitative study with snowball sampling technique was used to identify fifteen dispensers working in community pharmacies in Islamabad, Peshawar and Lahore. Semi-structured interviews were conducted with the dispensers until the point of saturation was obtained. The interviews which focused on three ...

  6. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  7. Percussion use and training: a survey of music therapy clinicians.

    Science.gov (United States)

    Scheffel, Stephanie; Matney, Bill

    2014-01-01

    Percussion instruments are commonly used in music therapy practice; however, the body of published literature regarding music therapy-related percussion training and practice is limited. The purpose of our survey study was to describe: (a) clinician perspectives of their academic percussion training; (b) use of percussion testing during academic training; (c) clinician perspectives on relevance, adequacy, and importance of academic percussion training; (d) clinician perspectives of their nonacademic percussion training; and (e) current use of percussion in clinical practice. Through comparisons of these parameters, we sought to provide information that may inform future percussion use and training. Participants were selected using an email list from the Certification Board for Music Therapists. Board-certified music therapists (MT-BC) were provided with a researcher-created survey about academic percussion training, nonacademic percussion training, and use of percussion in clinical practice. Survey response rate was 14.4% (611/4234). We used demographic data to address potential nonresponse error and ensure population representation for region of residence and region of academic training. Results revealed concerns about perceived adequacy of percussion training received during music therapy education (14.6% reported receiving no academic percussion training; 40.6% reported training was not adequate), and absence of percussion-specific proficiency exams. Of the training received, 62.8% indicated that training was relevant; however, a majority (76.5%) recommended current music therapy students receive more percussion training on instruments and skills most relevant to clinical practice. Comparisons between academic training, perceived needs in academic training, and clinical usage may inform future training and clinical competency. We provide suggestions for developing future training, as well as for furthering clinical implementation and research. © the American

  8. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Methods: A qualitative study with snowball sampling technique was used to ... Semi-structured interviews were conducted with the dispensers until the ... and suggestions for improvements were audio-taped, transcribed verbatim and analyzed.

  9. Perceptions of Dispensers Regarding Dispensing Practices in ...

    African Journals Online (AJOL)

    Erah

    1School of Pharmaceutical Sciences, University Sains Malaysia, 11800 Penang, Malaysia, 2Department of Social ... working in community pharmacies in Islamabad, Peshawar and Lahore. ..... situation regarding dispensing practices in the.

  10. Experimental Highlights upon Tangential Percussions in Mechanical Systems

    Directory of Open Access Journals (Sweden)

    Stelian Alaci

    2014-12-01

    Full Text Available The paper presents a proposed method for underlying the presence of tangential percussions occurring in multibody systems. Tangential percussions define a relatively newly introduced concept required by the necessity of explaining the sudden change in the state of motion for two bodies interacting only on a direction from the common tangent plane. In robotics domain, normal and tangential percussions are widely met in the case of robotic hands in the moment of contacting the manipulated object.

  11. Korean Percussion Ensemble ("Samulnori") in the General Music Classroom

    Science.gov (United States)

    Kang, Sangmi; Yoo, Hyesoo

    2016-01-01

    This article introduces "samulnori" (Korean percussion ensemble), its cultural background, and instructional methods as parts of a classroom approach to teaching upper-level general music. We introduce five of eight sections from "youngnam nong-ak" (a style of samulnori) as a repertoire for teaching Korean percussion music to…

  12. Safe pill-dispensing.

    Science.gov (United States)

    Testa, Massimiliano; Pollard, John

    2007-01-01

    Each patient is supplied with a smart-card containing a Radio Frequency IDentification (RFID) chip storing a unique identification code. The patient places the Smart-card on a pill-dispenser unit containing an RFID reader. The RFID chip is read and the code sent to a Base-station via a wireless Bluetooth link. A database containing both patient details and treatment information is queried at the Base-station using the RFID as the search key. The patient's treatment data (i.e., drug names, quantities, time, etc.) are retrieved and sent back to the pill-dispenser unit via Bluetooth. Appropriate quantities of the required medications are automatically dispensed, unless the patient has already taken his/her daily dose. Safe, confidential communication and operation is ensured.

  13. Diastolic timed Vibro-Percussion at 50 Hz delivered across a chest wall sized meat barrier enhances clot dissolution and remotely administered Streptokinase effectiveness in an in-vitro model of acute coronary thrombosis

    OpenAIRE

    Hoffmann, Andrew; Gill, Harjit

    2012-01-01

    Abstract Background Low Frequency Vibro-Percussion (LFVP) assists clearance of thrombi in catheter systems and when applied to the heart and timed to diastole is known to enhance coronary flow. However LFVP on a clotted coronary like vessel given engagement over a chest wall sized barrier (to resemble non-invasive heart attack therapy) requires study. Methods One hour old clots (n=16) were dispensed within a flexible segment of Soft-Flo catheter (4 mm lumen), weighted, interfaced with Heparin...

  14. Timing Variations in Two Balkan Percussion Performances

    Directory of Open Access Journals (Sweden)

    Daniel Goldberg

    2016-01-01

    Full Text Available Many songs and dance pieces from the Balkan Peninsula employ aksak meter, in which two categorically different durations, long and short, coexist in the sequence of beats that performers emphasize and listeners move to. This paper analyzes the durations of aksak beats and measures in two recorded percussion performances that use a particular aksak beat sequence, long-short-short. The results suggest that the timing of beats varies in conjunction with factors including melodic grouping and interaction among members of a performing ensemble and audience. Timing variation linked to melodic groups occurs on a solo recording of a Macedonian Romani folk song. The performer, Muzafer Bizlim, taps an ostinato while singing, and the timing of his taps seems to mark some local and large-scale group boundaries. Melodic organization also seems relevant to the timing of beats and measures on a recording of Bulgarian percussionist Mitko Popov playing the tŭpan, a double-headed bass drum, in a small folk music ensemble. In Popov’s performance, however, timing differences might be related to characteristics of the ensemble dynamic, such as the coordination of multiple musical participants. These interpretations generate possibilities for future study of timing variations in relation to rhythm and meter.

  15. One-Stop Dispensing

    DEFF Research Database (Denmark)

    Houlind, Morten Baltzer; McNulty, Helle Bach Ølgaard; Treldal, Charlotte

    2018-01-01

    (1) Objective: To assess hospital medication costs and staff time between One-Stop Dispensing (OSD) and the Traditional Medication System (TMS), and to evaluate patient perspectives on OSD. (2) Methods: The study was conducted at Hvidovre Hospital, University of Copenhagen, Denmark in an elective...... gastric surgery and acute orthopedic surgery department. This study consists of three sub-studies including adult patients able to self-manage medication. In Sub-study 1, staff time used to dispense and administer medication in TMS was assessed. Medication cost and OSD staff time were collected in Sub......-study 2, while patient perspectives were assessed in Sub-study 3. Medication costs with two days of discharge medication were compared between measured OSD cost and simulated TMS cost for the same patients. Measured staff time in OSD was compared to simulated staff time in TMS for the same patients...

  16. Percussive drilling application of translational motion permanent magnet machine

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shujun

    2012-07-01

    It is clear that percussive drills are very promising since they can increase the rate of penetration in hard rock formations. Any small improvements on the percussive drills can make a big contribution to lowering the drilling costs since drilling a well for the oil and gas industry is very costly. This thesis presents a percussive drilling system mainly driven by a tubular reciprocating translational motion permanent magnet synchronous motor (RTPMSM), which efficiently converts electric energy to kinetic energy for crushing the hard rock since there is no mechanical media. The thesis starts from state-of-the-art of percussive drilling techniques, reciprocating translational motion motors, and self-sensing control of electric motors and its implementation issues. The following chapters present modeling the hard rock, modeling the drill, the design issues of the drill, the RTPMSM and its control. A single-phase RTPMSM prototype is tested for the hard rock drilling. The presented variable voltage variable frequency control is also validated on it. The space vector control and self-sensing control are also explored on a three-phase RTPMSM prototype. The results show that the percussive drill can be implemented to the hard rock drilling applications. A detailed summarisation of contributions and future work is presented at the end of the thesis.(Author)

  17. Quantifying traces of tool use: a novel morphometric analysis of damage patterns on percussive tools.

    Directory of Open Access Journals (Sweden)

    Matthew V Caruana

    Full Text Available Percussive technology continues to play an increasingly important role in understanding the evolution of tool use. Comparing the archaeological record with extractive foraging behaviors in nonhuman primates has focused on percussive implements as a key to investigating the origins of lithic technology. Despite this, archaeological approaches towards percussive tools have been obscured by a lack of standardized methodologies. Central to this issue have been the use of qualitative, non-diagnostic techniques to identify percussive tools from archaeological contexts. Here we describe a new morphometric method for distinguishing anthropogenically-generated damage patterns on percussive tools from naturally damaged river cobbles. We employ a geomatic approach through the use of three-dimensional scanning and geographical information systems software to statistically quantify the identification process in percussive technology research. This will strengthen current technological analyses of percussive tools in archaeological frameworks and open new avenues for translating behavioral inferences of early hominins from percussive damage patterns.

  18. Quantifying Traces of Tool Use: A Novel Morphometric Analysis of Damage Patterns on Percussive Tools

    Science.gov (United States)

    Caruana, Matthew V.; Carvalho, Susana; Braun, David R.; Presnyakova, Darya; Haslam, Michael; Archer, Will; Bobe, Rene; Harris, John W. K.

    2014-01-01

    Percussive technology continues to play an increasingly important role in understanding the evolution of tool use. Comparing the archaeological record with extractive foraging behaviors in nonhuman primates has focused on percussive implements as a key to investigating the origins of lithic technology. Despite this, archaeological approaches towards percussive tools have been obscured by a lack of standardized methodologies. Central to this issue have been the use of qualitative, non-diagnostic techniques to identify percussive tools from archaeological contexts. Here we describe a new morphometric method for distinguishing anthropogenically-generated damage patterns on percussive tools from naturally damaged river cobbles. We employ a geomatic approach through the use of three-dimensional scanning and geographical information systems software to statistically quantify the identification process in percussive technology research. This will strengthen current technological analyses of percussive tools in archaeological frameworks and open new avenues for translating behavioral inferences of early hominins from percussive damage patterns. PMID:25415303

  19. Results from Testing of Two Rotary Percussive Drilling Systems

    Science.gov (United States)

    Kriechbaum, Kristopher; Brown, Kyle; Cady, Ian; von der Heydt, Max; Klein, Kerry; Kulczycki, Eric; Okon, Avi

    2010-01-01

    The developmental test program for the MSL (Mars Science Laboratory) rotary percussive drill examined the e ect of various drill input parameters on the drill pene- tration rate. Some of the input parameters tested were drill angle with respect to gravity and percussive impact energy. The suite of rocks tested ranged from a high strength basalt to soft Kaolinite clay. We developed a hole start routine to reduce high sideloads from bit walk. The ongoing development test program for the IMSAH (Integrated Mars Sample Acquisition and Handling) rotary percussive corer uses many of the same rocks as the MSL suite. An additional performance parameter is core integrity. The MSL development test drill and the IMSAH test drill use similar hardware to provide rotation and percussion. However, the MSL test drill uses external stabilizers, while the IMSAH test drill does not have external stabilization. In addition the IMSAH drill is a core drill, while the MSL drill uses a solid powdering bit. Results from the testing of these two related drilling systems is examined.

  20. Emotional and psychophysiological responses to tempo, mode, and percussiveness

    NARCIS (Netherlands)

    van der Zwaag, Marjolein; Westerink, Joyce H.D.M.; van den Broek, Egon

    People often listen to music to influence their emotional state. However, the specific musical characteristics which cause this process are not yet fully understood. We have investigated the influence of the musical characteristics of tempo, mode and percussiveness on our emotions. In a quest

  1. E85 Dispenser Study

    Energy Technology Data Exchange (ETDEWEB)

    Moriarty, K.; Johnson, C.; Sears, T.; Bergeron, P.

    2009-12-01

    This study reviews E85 dispensing infrastructure advances and issues and evaluates the geographic concentration of flexible fuel vehicles (FFVs), E85 stations, ethanol production facilities, and E85 suppliers. Costs, space, financial incentives, and barriers to adding E85 fueling equipment at existing stations are also assessed. This study found that E85 is increasingly available in the U.S. in half of the states; however, the other half have minimal or no E85 fueling options. Despite these gains, E85 is only available at 1% of U.S. gasoline stations. Ethanol production reached 9.5 billion gallons in 2008, but less than 1% is consumed as E85. FFVs have not reached a significant concentration in any county, metropolitan area, or state.

  2. Body Percussion and Team Building through the BAPNE Method

    Directory of Open Access Journals (Sweden)

    Romero-Naranjo A.A.

    2016-01-01

    Full Text Available BAPNE Method is a method based on cognitive stimulation integrating music and movement through body percussion. The aim of this research is to explore its whole potential as a tool to build teams. Team building is a philosophy for work design, and since over two decades ago, it defends that obtaining a high performance and organizing efficiency is more useful to perceive employees as interdependent members in a team of work than individuals ones. From this viewpoint, this research advocates that BAPNE Method’s body percussion practice will have an impact on this vision of team work directly. For its own characteristics, body percussion stimulates ways of contact in movement, which ease social ties and, especially, promote group cohesion. Through social, body and, affective dimension; BAPNE Method is capable of developing a shared vision and a single aim, to stimulate team work identity and an atmosphere of trust; and finally, to improve individual communication and satisfaction levels in group tasks.

  3. Advanced Percussive Drilling Technology for Geothermal Exploration and Development

    Energy Technology Data Exchange (ETDEWEB)

    Su, Jiann [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Raymond, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Prasad, Somuri [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wolfer, Dale [Atlas-Copco Secoroc LLC, Fagersta (Sweden)

    2017-06-12

    Percussive hammers are a promising advance in drilling technology for geothermal since they rely upon rock reduction mechanisms that are well-suited for use in the hard, brittle rock characteristic of geothermal formations. The project research approach and work plan includes a critical path to development of a high-temperature (HT) percussive hammer using a two phase approach. The work completed in Phase I of the project demonstrated the viability of percussive hammers and that solutions to technical challenges in design, material technology, and performance are likely to be resolved. Work completed in Phase II focused on testing the findings from Phase I and evaluating performance of the materials and designs at high operating temperatures. A high-operating temperature (HOT) drilling facility was designed, built, and used to test the performance of the DTH under extreme conditions. Results from the testing indicate that a high-temperature capable hammer can be developed and is a viable alternative for use in the driller’s toolbox.

  4. Quantifying Traces of Tool Use: A Novel Morphometric Analysis of Damage Patterns on Percussive Tools

    OpenAIRE

    Caruana, Matthew V.; Carvalho, Susana; Braun, David R.; Presnyakova, Darya; Haslam, Michael; Archer, Will; Bobe, Rene; Harris, John W. K.

    2014-01-01

    Percussive technology continues to play an increasingly important role in understanding the evolution of tool use. Comparing the archaeological record with extractive foraging behaviors in nonhuman primates has focused on percussive implements as a key to investigating the origins of lithic technology. Despite this, archaeological approaches towards percussive tools have been obscured by a lack of standardized methodologies. Central to this issue have been the use of qualitative, non-diagnost...

  5. PENETRATION OF CONICAL INDENTER INTO FOUNDATION MATERIAL AT COMBINED PERCUSSION AND SUBSEQUENT ULTRASONIC IMPACTS

    Directory of Open Access Journals (Sweden)

    M. G. Kiselev

    2012-01-01

    Full Text Available The aim of this paper is theoretical and experimental studys of a percussion and subsequent ultrasonic impacts on the indenter depth penetration into material of rigid-plastic foundation.The obtained results allow us to estimate an influence of percussion (low-frequency and ultrasound (high-frequency component parameters on a charging process.

  6. 49 CFR 178.318 - Specification MC 201; container for detonators and percussion caps.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Specification MC 201; container for detonators and percussion caps. 178.318 Section 178.318 Transportation Other Regulations Relating to Transportation PIPELINE....318 Specification MC 201; container for detonators and percussion caps. ...

  7. 21 CFR 888.4200 - Cement dispenser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cement dispenser. 888.4200 Section 888.4200 Food... DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4200 Cement dispenser. (a) Identification. A cement dispenser is a nonpowered syringe-like device intended for use in placing bone cement (§ 888.3027) into...

  8. Emission characteristics of dispenser cathodes with a fine-grained tungsten top layer

    Science.gov (United States)

    Kimura, S.; Higuchi, T.; Ouchi, Y.; Uda, E.; Nakamura, O.; Sudo, T.; Koyama, K.

    1997-02-01

    In order to improve the emission stability of the Ir-coated dispenser cathode under ion bombardment, a fine-grained tungsten top layer was applied on the substrate porous tungsten plug before Ir coating. The emission characteristics were studied after being assembled in a CRT gun. Cathode current was measured under pulse operation in a range of 0.1-9% duty. Remarkable anti-ion bombardment characteristics were observed over the range of 1-6% duty. The improved cathode showed 1.5 times higher emission current than that of a conventional Ir-coated dispenser cathode at 4% duty. AES analysis showed that the recovering rates of surface Ba and O atoms after ion bombardment were 2.5 times higher. From these results it is confirmed that the Ir coated cathode with a fine-grained tungsten top layer is provided with a good tolerance against the ion bombardment.

  9. Percussion drilling cone penetrometer with wireless operating in-tip gaschromatograph

    Energy Technology Data Exchange (ETDEWEB)

    Bracht, C.; Matz, G. [Technische Univ. Hamburg-Harburg, Hamburg (Germany)

    2003-07-01

    Percussion drilling cone penetrometric analysis is the fast alternative to soil sampling and laboratory analyses. Online detection enables the characterization of a large variety of contaminants in soil. This becomes very important in the reactivation of contaminated sites. Therefore a new system has been constructed, which avoids tedious harness handling through the penetrometer drill rods and minimizes the time for an analysis down to 30 minutes per drill hole. This system enables the in-situ analysis of soil gases up to a depth of 10 to 15 meters. This system consists of a remote controlled in-tip mounted gaschromatograph, a special gas inlet module and a data transfer unit including a rechargeable battery pack. The modules are shock proved to be suitable for percussion drilling techniques and can be removed easily for maintenance. A PDA (Pocket PC) controls the subsoil gaschromatograph unit, calculates and displays the concentration of the detected compounds and stores the acquired data. The gaschromatograph until is optimized to analyze VOCs e.g. BTEX within 10 seconds per analysis. It consists of a loop inlet, a capillary column and a Photo Ionization Detector. It is microcontroller operated and battery powered. The inlet module is optimized soil gases. It includes a sensor and solenoid valve system for water protection and humidity acquisition while drilling. A completely charged battery pack provides up to three hours of analyses. It could be exchanged fast and easy to enable continuous analyses. Digital data transfer between subsoil unit and surface is provided wireless by IR light through the rods. On surface data is transferred wireless by BLUETOOTH radio link to the PDA. The depth of the penetrometer, global position and local time are acquired on-line onto the surface and are transferred on request by BLUETOOTH radio link to the PDA. The wireless data transfer and battery powered modules avoid time consuming cable handling and enable this cone

  10. Rotary Percussive Auto-Gopher for Deep Drilling and Sampling

    Science.gov (United States)

    Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart

    2009-01-01

    The term "rotary percussive auto-gopher" denotes a proposed addition to a family of apparatuses, based on ultrasonic/ sonic drill corers (USDCs), that have been described in numerous previous NASA Tech Briefs articles. These apparatuses have been designed, variously, for boring into, and/or acquiring samples of, rock or other hard, brittle materials of geological interest. In the case of the rotary percussive autogopher, the emphasis would be on developing an apparatus capable of penetrating to, and acquiring samples at, depths that could otherwise be reached only by use of much longer, heavier, conventional drilling-and-sampling apparatuses. To recapitulate from the prior articles about USDCs: A USDC can be characterized as a lightweight, low-power jackhammer in which a piezoelectrically driven actuator generates ultrasonic vibrations and is coupled to a tool bit through a free mass. The bouncing of the free mass between the actuator horn and the drill bit converts the actuator ultrasonic vibrations into sonic hammering of the drill bit. The combination of ultrasonic and sonic vibrations gives rise to a hammering action (and a resulting chiseling action at the tip of the tool bit) that is more effective for drilling than is the microhammering action of ultrasonic vibrations alone. The hammering and chiseling actions are so effective that the size of the axial force needed to make the tool bit advance into soil, rock, or another material of interest is much smaller than in ordinary rotary drilling, ordinary hammering, or ordinary steady pushing. The predecessor of the rotary percussive auto-gopher is an apparatus, now denoted an ultrasonic/sonic gopher and previously denoted an ultrasonic gopher, described in "Ultrasonic/ Sonic Mechanism for Drilling and Coring" (NPO-30291), NASA Tech Briefs Vol. 27, No. 9 (September 2003), page 65. The ultrasonic/sonic gopher is intended for use mainly in acquiring cores. The name of the apparatus reflects the fact that, like a

  11. Percussive Augmenter of Rotary Drills for Operating as a Rotary-Hammer Drill

    Science.gov (United States)

    Aldrich, Jack Barron (Inventor); Bar-Cohen, Yoseph (Inventor); Sherrit, Stewart (Inventor); Badescu, Mircea (Inventor); Bao, Xiaoqi (Inventor); Scott, James Samson (Inventor)

    2014-01-01

    A percussive augmenter bit includes a connection shaft for mounting the bit onto a rotary drill. In a first modality, an actuator percussively drives the bit, and an electric slip-ring provides power to the actuator while being rotated by the drill. Hammering action from the actuator and rotation from the drill are applied directly to material being drilled. In a second modality, a percussive augmenter includes an actuator that operates as a hammering mechanism that drives a free mass into the bit creating stress pulses that fracture material that is in contact with the bit.

  12. Human-based percussion and self-similarity detection in electroacoustic music

    Science.gov (United States)

    Mills, John Anderson, III

    Electroacoustic music is music that uses electronic technology for the compositional manipulation of sound, and is a unique genre of music for many reasons. Analyzing electroacoustic music requires special measures, some of which are integrated into the design of a preliminary percussion analysis tool set for electroacoustic music. This tool set is designed to incorporate the human processing of music and sound. Models of the human auditory periphery are used as a front end to the analysis algorithms. The audio properties of percussivity and self-similarity are chosen as the focus because these properties are computable and informative. A collection of human judgments about percussion was undertaken to acquire clearly specified, sound-event dimensions that humans use as a percussive cue. A total of 29 participants was asked to make judgments about the percussivity of 360 pairs of synthesized snare-drum sounds. The grouped results indicate that of the dimensions tested rise time is the strongest cue for percussivity. String resonance also has a strong effect, but because of the complex nature of string resonance, it is not a fundamental dimension of a sound event. Gross spectral filtering also has an effect on the judgment of percussivity but the effect is weaker than for rise time and string resonance. Gross spectral filtering also has less effect when the stronger cue of rise time is modified simultaneously. A percussivity-profile algorithm (PPA) is designed to identify those instants in pieces of music that humans also would identify as percussive. The PPA is implemented using a time-domain, channel-based approach and psychoacoustic models. The input parameters are tuned to maximize performance at matching participants' choices in the percussion-judgment collection. After the PPA is tuned, the PPA then is used to analyze pieces of electroacoustic music. Real electroacoustic music introduces new challenges for the PPA, though those same challenges might affect

  13. A Study of Specific Fracture Energy at Percussion Drilling

    Science.gov (United States)

    A, Shadrina; T, Kabanova; V, Krets; L, Saruev

    2014-08-01

    The paper presents experimental studies of rock failure provided by percussion drilling. Quantification and qualitative analysis were carried out to estimate critical values of rock failure depending on the hammer pre-impact velocity, types of drill bits and cylindrical hammer parameters (weight, length, diameter), and turn angle of a drill bit. Obtained data in this work were compared with obtained results by other researchers. The particle-size distribution in granite-cutting sludge was analyzed in this paper. Statistical approach (Spearmen's rank-order correlation, multiple regression analysis with dummy variables, Kruskal-Wallis nonparametric test) was used to analyze the drilling process. Experimental data will be useful for specialists engaged in simulation and illustration of rock failure.

  14. A Study of Specific Fracture Energy at Percussion Drilling

    International Nuclear Information System (INIS)

    Shadrina A; Krets V; Saruev L; Kabanova T

    2014-01-01

    The paper presents experimental studies of rock failure provided by percussion drilling. Quantification and qualitative analysis were carried out to estimate critical values of rock failure depending on the hammer pre-impact velocity, types of drill bits and cylindrical hammer parameters (weight, length, diameter), and turn angle of a drill bit. Obtained data in this work were compared with obtained results by other researchers. The particle-size distribution in granite-cutting sludge was analyzed in this paper. Statistical approach (Spearmen's rank-order correlation, multiple regression analysis with dummy variables, Kruskal-Wallis nonparametric test) was used to analyze the drilling process. Experimental data will be useful for specialists engaged in simulation and illustration of rock failure

  15. Dose dispenser for radioactive gas

    International Nuclear Information System (INIS)

    Horwitz, N.H.; Gutkowski, R.E.

    1977-01-01

    An activity metering apparatus for metering predetermined activities of radioactive gas from a supply ampul to dose vials is described. The apparatus includes a shielded ampul housing, a fine metering valve communicating with the ampul housing chamber, a shielded vial housing and a hypodermic needle communicating with the metering valve and received through an opening in the vial housing. A Geiger-Muller tube is adjustably supported opposite an opening in the vial housing, whereby the activity of the radioactive gas dispensed to a partially evacuated vial within the vial chamber may be read directly by a standard laboratory rate meter

  16. A compact 133Xe gas dispenser

    International Nuclear Information System (INIS)

    Hawkins, T.; Harris, R.

    1977-01-01

    A dispenser for 133 Xe gas is described which is compact and simple to use, allowing the xenon to be dispensed from it shipping ampoule to suitable multi-dose injection vials in a controlled manner and with a high degree of operator safety. The apparatus has no joints and only a single rubber teat, minimizing the risks of adsorption and leakage. A scaled drawing of the dispenser is shown. (U.K.)

  17. Methods for Evaluating the Performance and Human Stress-Factors of Percussive Riveting

    Science.gov (United States)

    Ahn, Jonathan Y.

    The aerospace industry automates portions of their manufacturing and assembly processes. However, mechanics still remain vital to production, especially in areas where automated machines cannot fit, or have yet to match the quality of human craftsmanship. One such task is percussive riveting. Because percussive riveting is associated with a high risk of injury, these tool must be certified prior to release. The major contribution of this thesis is to develop a test bench capable of percussive riveting for ergonomic evaluation purposes. The major issues investigated are: (i) automate the tool evaluation method to be repeatable; (ii) demonstrate use of displacement and force sensors; and (iii) correlate performance and risk exposure of percussive tools. A test bench equipped with servomotors and pneumatic cylinders to control xyz-position of a rivet gun and bucking bar simultaneously, is used to explore this evaluation approach.

  18. Lightweight Low Force Rotary Percussive Coring Tool for Planetary Applications, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Alliance Spacesystems, LLC produced a rotary percussive drill designed for space use under a NASA-funded Mars Instrument Development Program (MIDP) project -- the...

  19. Development of the RANCOR Rotary-Percussive Coring System for Mars Sample Return

    Science.gov (United States)

    Paulsen, Gale; Indyk, Stephen; Zacny, Kris

    2014-01-01

    A RANCOR drill was designed to fit a Mars Exploration Rover (MER) class vehicle. The low mass of 3 kg was achieved by using the same actuator for three functions: rotation, percussions, and core break-off. Initial testing of the drill exposed an unexpected behavior of an off-the-shelf sprag clutch used to couple and decouple rotary-percussive function from the core break off function. Failure of the sprag was due to the vibration induced during percussive drilling. The sprag clutch would back drive in conditions where it was expected to hold position. Although this did not affect the performance of the drill, it nevertheless reduced the quality of the cores produced. Ultimately, the sprag clutch was replaced with a custom ratchet system that allowed for some angular displacement without advancing in either direction. Replacing the sprag with the ratchet improved the collected core quality. Also, premature failure of a 300-series stainless steel percussion spring was observed. The 300-series percussion spring was ultimately replaced with a music wire spring based on performances of previously designed rotary-percussive drill systems.

  20. Antimalarial Drugs for Pediatrics - Prescribing and Dispensing ...

    African Journals Online (AJOL)

    Purpose: To assess dispensing and prescribing practices with regard to antimalarial drugs for pediatrics in private pharmacies and public hospitals in Dar es Salaam, Tanzania. Methods: This was a cross-sectional, descriptive study that assessed the knowledge and practice of 200 drug dispensers in the private community ...

  1. Dissolvable microneedle fabrication using piezoelectric dispensing technology.

    Science.gov (United States)

    Allen, Evin A; O'Mahony, Conor; Cronin, Michael; O'Mahony, Thomas; Moore, Anne C; Crean, Abina M

    2016-03-16

    Dissolvable microneedle (DMN) patches are novel dosage forms for the percutaneous delivery of vaccines. DMN are routinely fabricated by dispensing liquid formulations into microneedle-shaped moulds. The liquid formulation within the mould is then dried to create dissolvable vaccine-loaded microneedles. The precision of the dispensing process is critical to the control of formulation volume loaded into each dissolvable microneedle structure. The dispensing process employed must maintain vaccine integrity. Wetting of mould surfaces by the dispensed formulation is also an important consideration for the fabrication of sharp-tipped DMN. Sharp-tipped DMN are essential for ease of percutaneous administration. In this paper, we demonstrate the ability of a piezoelectric dispensing system to dispense picolitre formulation volumes into PDMS moulds enabling the fabrication of bilayer DMN. The influence of formulation components (trehalose and polyvinyl alcohol (PVA) content) and piezoelectric actuation parameters (voltage, frequency and back pressure) on drop formation is described. The biological integrity of a seasonal influenza vaccine following dispensing was investigated and maintained voltage settings of 30 V but undermined at higher settings, 50 and 80 V. The results demonstrate the capability of piezoelectric dispensing technology to precisely fabricate bilayer DMN. They also highlight the importance of identifying formulation and actuation parameters to ensure controlled droplet formulation and vaccine stabilisation. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. PROGRAMMABLE METRONOME FOR PERCUSSION INSTRUMENTS AND AN APPLICATION

    Directory of Open Access Journals (Sweden)

    Hasan Selçuk Selek

    2012-01-01

    Full Text Available Applications of electronics in the music industry have been increasing continuosly. Develpoments in electro music and electro music instruments make this possible. Although it is known that the majority of musicians are against the digital music and techniques, researches show that it would be very benefical for teaching and learning of playing music intruments. This study shows that, music and electronic applications can be useable with together in the same projects. With this equipment people can practice on their own percussion studies. System designed as, speed and hit force in case of faulty users can be warned by program. Warning can be reailized as a visual with LED and also can be done with sound. In this study, at the same time shows that, without using physical metronome, metronome software and designed card can use at applications is may be possible. Based on the study is a software metronome and its card which can be used for all musical intruments. Designed metronome was tested for a electronic drum with a compare circuit. PIC-C compiler was used in order to get the designed card to work compatible with PIC. The circuit designed for the metronome is integrated with compare circuit and has been tested together.

  3. Percussive technology in human evolution: an introduction to a comparative approach in fossil and living primates.

    Science.gov (United States)

    de la Torre, Ignacio; Hirata, Satoshi

    2015-11-19

    Percussive technology is part of the behavioural suite of several fossil and living primates. Stone Age ancestors used lithic artefacts in pounding activities, which could have been most important in the earliest stages of stone working. This has relevant evolutionary implications, as other primates such as chimpanzees and some monkeys use stone hammer-and-anvil combinations to crack hard-shelled foodstuffs. Parallels between primate percussive technologies and early archaeological sites need to be further explored in order to assess the emergence of technological behaviour in our evolutionary line, and firmly establish bridges between Primatology and Archaeology. What are the anatomical, cognitive and ecological constraints of percussive technology? How common are percussive activities in the Stone Age and among living primates? What is their functional significance? How similar are archaeological percussive tools and those made by non-human primates? This issue of Phil. Trans. addresses some of these questions by presenting case studies with a wide chronological, geographical and disciplinary coverage. The studies presented here cover studies of Brazilian capuchins, captive chimpanzees and chimpanzees in the wild, research on the use of percussive technology among modern humans and recent hunter-gatherers in Australia, the Near East and Europe, and archaeological examples of this behaviour from a million years ago to the Holocene. In summary, the breadth and depth of research compiled here should make this issue of Philosophical Transactions of the Royal Society B, a landmark step forward towards a better understanding of percussive technology, a unique behaviour shared by some modern and fossil primates. © 2015 The Author(s).

  4. Prescription habits of dispensing and non-dispensing doctors in Zimbabwe

    DEFF Research Database (Denmark)

    Trap, Birna; Hansen, Ebba Holme; Hogerzeil, Hans V

    2002-01-01

    , race, place of education, location of practice and patients seen per day showed that dispensing by doctors was associated with less clinically and economically appropriate prescribing. These findings suggest that the quality of health care--as related to drug use, patient safety and treatment cost......The number of dispensing doctors has increased in the last decade, but the implication of this trend on the quality of health care and drug use is unknown. We present a comparative drug utilization study of 29 dispensing doctors and 28 non-dispensing doctors in Zimbabwe based on standard indicators...... developed by the World Health Organization. Dispensing doctors prescribed significantly more drugs per patient than non-dispensing doctors (2.3 versus 1.7), injected more patients (28.4% versus 9.5%), and prescribed more antibiotics (0.72 versus 0.54) and mixtures (0.43 versus 0.25) per encounter...

  5. Developmental test report, assessment of XT-70E percussion drill rig operation in tank farms

    International Nuclear Information System (INIS)

    Dougherty, L.F.

    1996-01-01

    The following report documents the testing of the XT-70E percussion drill rig for use in the 241-SX Tank Farm. The test is necessary to support evaluation of the safety and authorization level of the proposed activity of installing up to three new drywells in the 241- SX Tank Farm. The proposed activity plans to install drywells by percussion drilling 7 inch O.D./6 inch I.D. pipe in close proximity of underground storage tanks and associated equipment. The load transmitted from the drill rig's percussion hammer through the ground to the tank structure and equipment is not known and therefore testing is required to ensure the activity is safe and authorized

  6. Automatic Quality Inspection of Percussion Cap Mass Production by Means of 3D Machine Vision and Machine Learning Techniques

    Science.gov (United States)

    Tellaeche, A.; Arana, R.; Ibarguren, A.; Martínez-Otzeta, J. M.

    The exhaustive quality control is becoming very important in the world's globalized market. One of these examples where quality control becomes critical is the percussion cap mass production. These elements must achieve a minimum tolerance deviation in their fabrication. This paper outlines a machine vision development using a 3D camera for the inspection of the whole production of percussion caps. This system presents multiple problems, such as metallic reflections in the percussion caps, high speed movement of the system and mechanical errors and irregularities in percussion cap placement. Due to these problems, it is impossible to solve the problem by traditional image processing methods, and hence, machine learning algorithms have been tested to provide a feasible classification of the possible errors present in the percussion caps.

  7. The Use of High-Frequency Percussive Ventilation for Whole-Lung Lavage: A Case Report.

    Science.gov (United States)

    Kinthala, Sudhakar; Liang, Mark; Khusid, Felix; Harrison, Sebron

    2018-04-23

    Whole-lung lavage (WLL) remains the gold standard in the treatment of pulmonary alveolar proteinosis. However, anesthetic management during WLL can be challenging because of the risk of intraoperative hypoxemia and various cardiorespiratory complications of 1-lung ventilation. Here, we describe a novel strategy involving the application of high-frequency percussive ventilation using a volumetric diffusive respirator (VDR-4) during WLL in a 47-year-old woman with pulmonary alveolar proteinosis. Our observations suggest that high-frequency percussive ventilation is a potentially effective ventilation strategy during WLL that may reduce the risk of hypoxemia and facilitate lavage.

  8. Development of Young Adults' Fine Motor Skills when Learning to Play Percussion Instruments

    Science.gov (United States)

    Gzibovskis, Talis; Marnauza, Mara

    2012-01-01

    When playing percussion instruments, the main activity is done with the help of a motion or motor skills; to perform it, developed fine motor skills are necessary: the speed and precision of fingers, hands and palms. The aim of the research was to study and test the development of young adults' fine motor skills while learning to play percussion…

  9. Analysis of percussion response of dental implants: An in vitro study

    International Nuclear Information System (INIS)

    Dinh, Andrew; Sheets, Cherilyn G.; Earthman, James C.

    2013-01-01

    The Periometer® quantitative percussion system was used to interrogate the interfacial stability of implants in vitro for comparison with X-ray computer tomography (CT) data. Selected implants were placed as per standard practice in bone stimulant polyurethane blocks. The dimensions of the surgical sites surrounding the implants were analyzed using X-ray computer tomography (CT) to determine the quality of support at the implant–bone interface. In particular, the misfit between the size of the surgical site and the corresponding implant was determined for each sample. The resulting average surgical site error from the CT scans was found to exhibit good agreement with the presence of irregularities found in the percussion data. - Highlights: ► Percussion response versus time exhibited irregularities for some in vitro samples. ► X-Ray CT was used to assess the interface integrity for six implant–bone specimens. ► Irregularities in percussion data correlate well with the CT based assessments

  10. The Schultz MIDI Benchmarking Toolbox for MIDI interfaces, percussion pads, and sound cards

    NARCIS (Netherlands)

    Schultz, Benjamin G

    2018-01-01

    The Musical Instrument Digital Interface (MIDI) was readily adopted for auditory sensorimotor synchronization experiments. These experiments typically use MIDI percussion pads to collect responses, a MIDI-USB converter (or MIDI-PCI interface) to record responses on a PC and manipulate feedback, and

  11. The Auto-Gopher: A Wireline Rotary-Percussive Deep Sampler

    Science.gov (United States)

    Bar-Cohen, Yoseph; Zacny, Kris; Badescu, Mircea; Lee, Hyeong Jae; Sherrit, Stewart; Bao, Xiaoqi; Paulsen, Gale L.; Beegle, Luther

    2016-01-01

    Accessing regions on planetary bodies that potentially preserved biosignatures or are presently habitable is vital to meeting NASA solar system "Search for Life" exploration objectives. To address these objectives, a wireline deep rotary-percussive corer called Auto-Gopher was developed. The percussive action provides effective material fracturing and the rotation provides effective cuttings removal. To increase the drill's penetration rate, the percussive and rotary motions are operated simultaneously. Initially, the corer was designed as a percussive mechanism for sampling ice and was demonstrated in 2005 in Antarctica reaching about 2 m deep. The lessons learned suggested the need to use a combination of rotation and hammering to maximize the penetration rate. This lesson was implemented into the Auto-Gopher-I deep drill which was demonstrated to reach 3-meter deep in gypsum. The average drilling power that was used has been in the range of 100-150 Watt, while the penetration rate was approximately 2.4 m/hr. Recently, a task has started with the goal to develop Auto-Gopher-II that is equipped to execute all the necessary functions in a single drilling unit. These functions also include core breaking, retention and ejection in addition drilling. In this manuscript, the Auto-Gopher-II, its predecessors and their capability are described and discussed.

  12. Prophylactic Use of High-Frequency Percussive Ventilation in Patients with Inhalation Injury,

    Science.gov (United States)

    1991-06-01

    Pneumonia ( CPAP ). The duration of the percussive phase and of the return to baseline phase are adjusted to manipulate ox- The diagnosis of pneumonia was...high-frequency ventilation than conventional support. using this form of ventilation in neonates , in which that incidence ap- Dr. Herndon asked about

  13. Electrical and percussive stunning of the common carp (Cyprinus carpio L.): Neurological and behavioural assessment

    NARCIS (Netherlands)

    Lambooij, E.; Pilarczyk, M.; Bialowas, H.; Boogaart, van den J.G.M.; Vis, van de J.W.

    2007-01-01

    The overall objective of the study was to evaluate electrical and percussive stunning methods under laboratory conditions in common carps. The electrical current needed to induce a general epileptiform insult was assessed in 13 carps. The insult was obtained by delivering a current of 0.24 ± 0.03 A

  14. What motivates antibiotic dispensing in accredited drug dispensing outlets in Tanzania? A qualitative study.

    Science.gov (United States)

    Dillip, Angel; Embrey, Martha; Shekalaghe, Elizabeth; Ross-Degnan, Dennis; Vialle-Valentin, Catherine; Kimatta, Suleiman; Liana, Jafary; Rutta, Edmund; Valimba, Richard; Chalker, John

    2015-01-01

    Tanzania introduced the accredited drug dispensing outlet (ADDO) program more than a decade ago. Previous evaluations have generally shown that ADDOs meet defined standards of practice better than non-accredited outlets. However, ADDOs still face challenges with overuse of antibiotics for acute respiratory infections (ARI) and simple diarrhea, which contributes to the emergence of drug resistance. This study aimed to explore the attitudes of ADDO owners and dispensers toward antibiotic dispensing and to learn how accreditation has influenced their dispensing behavior. The study used a qualitative approach. We conducted in-depth interviews with ADDO owners and dispensers in Ruvuma and Tanga regions where the government implemented the ADDO program under centralized and decentralized approaches, respectively; a secondary aim was to compare differences between the two regions. Findings indicate that the ADDO program has brought about positive changes in knowledge of dispensing practices. Respondents were able to correctly explain treatment guidelines for ARI and diarrhea. Almost all dispensers and owners indicated that unnecessary use of antibiotics contributed to antimicrobial resistance. Despite this knowledge, translating it to appropriate dispensing practice is still low. Dispensers' behavior is driven by customer demand, habit ("mazoea"), following inappropriate health facility prescriptions, and the need to make a profit. Although the majority of dispensers reported that they had intervened in situations where customers asked for antibiotics unnecessarily, they tended to give in to clients' requests. Small variations were noted between the two study regions; for example, some dispensers in Ruvuma reported sending clients with incorrect prescriptions back to the health facility, a practice that may reflect regional differences in ADDO implementation and in Integrated Management of Childhood Illness training. Dispensers in rural settings reported more challenges

  15. Methods for dispensing mercury into devices

    Science.gov (United States)

    Grossman, Mark W.; George, William A.

    1987-04-28

    A process for dispensing mercury into devices which requires mercury. Mercury is first electrolytically separated from either HgO or Hg.sub.2 Cl.sub.2 and plated onto a cathode wire. The cathode wire is then placed into a device requiring mercury.

  16. Alcohol Dispenser Training in Amherst Massachusetts

    Science.gov (United States)

    Riccelli, Carlene

    1986-01-01

    Reviews efforts of the Alcohol Dispenser Training program in Amherst, Massachusetts over a five-year period. Evaluations indicate that participants agree that training is worthwhile, that they are more aware of the effects of alcohol on their patrons, and that they have better knowledge of appropriate strategies for preventing intoxication of…

  17. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...

  18. Development of alloy-film coated dispenser cathode for terahertz vacuum electron devices application

    International Nuclear Information System (INIS)

    Barik, R.K.; Bera, A.; Raju, R.S.; Tanwar, A.K.; Baek, I.K.; Min, S.H.; Kwon, O.J.; Sattorov, M.A.; Lee, K.W.; Park, G.-S.

    2013-01-01

    High power terahertz vacuum electron devices demand high current density and uniform emission dispenser cathode. It was found that the coating of noble metals e.g., Os, Ir, and Re on the surface of tungsten dispenser cathodes enhances the emission capabilities and uniformity. Hence metal coated cathode might be the best candidate for terahertz devices applications. In this study, ternary-alloy-film cathode (2Os:2Re:1 W) and Os coated cathode have been developed and the results are presented. The cathodes made out of this alloy coating showed 1.5 times higher emission and 0.02 eV emission uniformity as compared to those of simply Os coated cathodes which can be used in terahertz devices application.

  19. Development of alloy-film coated dispenser cathode for terahertz vacuum electron devices application

    Energy Technology Data Exchange (ETDEWEB)

    Barik, R. K.; Bera, A. [School of Electrical Engineering and Computer Science, Seoul National University, Seoul (Korea, Republic of); Raju, R. S. [Central Electronics Engineering Research Institute (CEERI), Rajasthan (India); Tanwar, A. K.; Baek, I. K.; Min, S. H.; Kwon, O. J.; Sattorov, M. A. [Department of Physics and Astronomy, Center for THz-Bio Application Systems, and Seoul-Teracom Inc., Seoul National University, Seoul (Korea, Republic of); Lee, K. W. [LIG Nex1, Seoul (Korea, Republic of); Park, G.-S., E-mail: gunsik@snu.ac.kr [School of Electrical Engineering and Computer Science, Seoul National University, Seoul (Korea, Republic of); Department of Physics and Astronomy, Center for THz-Bio Application Systems, and Seoul-Teracom Inc., Seoul National University, Seoul (Korea, Republic of); Advanced Institute of Convergence Technology, Suwon-si, Gyeonggi-do (Korea, Republic of)

    2013-07-01

    High power terahertz vacuum electron devices demand high current density and uniform emission dispenser cathode. It was found that the coating of noble metals e.g., Os, Ir, and Re on the surface of tungsten dispenser cathodes enhances the emission capabilities and uniformity. Hence metal coated cathode might be the best candidate for terahertz devices applications. In this study, ternary-alloy-film cathode (2Os:2Re:1 W) and Os coated cathode have been developed and the results are presented. The cathodes made out of this alloy coating showed 1.5 times higher emission and 0.02 eV emission uniformity as compared to those of simply Os coated cathodes which can be used in terahertz devices application.

  20. Design of a Percussion and Electric Primer Gun Firing Power Supply

    Science.gov (United States)

    2014-07-01

    solenoid failure. As new instrumentation techniques such as high-speed video and laser interferometry have been introduced into our gun testing...to drive a solenoid into a percussion primer or ignite the M52A3B1 electric primer. To reduce power requirements, it uses charged capacitor banks to...drive the solenoid or ignite the primer. This report details the design and construction of the power supplies. 15. SUBJECT TERMS power supply

  1. percussions de la libéralisation du commerce des services sur le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    percussions de la libéralisation du commerce des services sur le développement. La documentation économique a démontré l'importance du secteur des services dans le processus de croissance économique et de développement social. Le principal défi auquel sont confrontés aujourd'hui les pays en développement ...

  2. Prise en compte des répercussions socioéconomiques de la culture ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Prise en compte des répercussions socioéconomiques de la culture du coton génétiquement modifié sur les petits agriculteurs du Mercosur. L'Argentine, le Brésil et le Paraguay, membres du Marché commun du cône sud (Mercosur), sont les cinquièmes producteurs de coton au monde, devancés uniquement par la Chine, ...

  3. Better Drumming Through Calibration: Techniques for Pre-Performance Robotic Percussion Optimization

    OpenAIRE

    Murphy, Jim; Kapur, Ajay; Carnegie, Dale

    2012-01-01

    A problem with many contemporary musical robotic percussion systems lies in the fact that solenoids fail to respond lin-early to linear increases in input velocity. This nonlinearity forces performers to individually tailor their compositions to specific robotic drummers. To address this problem, we introduce a method of pre-performance calibration using metaheuristic search techniques. A variety of such techniques are introduced and evaluated and the results of the optimized solenoid-based p...

  4. Auto-Gopher: A Wireline Deep Sampler Driven by Piezoelectric Percussive Actuator and EM Rotary Motor

    Science.gov (United States)

    Badescu, Mircea; Ressa, Aaron; Jae Lee, Hyeong; Bar-Cohen, Yoseph; Sherrit, Stewart; Zacny, Kris; Paulsen, Gale L.; Beegle, Luther; Bao, Xiaoqi

    2013-01-01

    The ability to penetrate subsurfaces and perform sample acquisition at depth of meters may be critical for future NASA in-situ exploration missions to bodies in the solar system, including Mars and Europa. A corer/sampler was developed with the goal of enabling acquisition of samples from depths of several meters where if used on Mars would be beyond the oxidized and sterilized zone. For this purpose, we developed a rotary-hammering coring drill, called Auto-Gopher, which employs a piezoelectric actuated percussive mechanism for breaking formations and an electric motor that rotates the bit to remove the powdered cuttings. This sampler is a wireline mechanism that can be fed into and retrieved from the drilled hole using a winch and a cable. It includes an inchworm anchoring mechanism allowing the drill advancement and weight on bit control without twisting the reeling and power cables. The penetration rate is being optimized by simultaneously activating the percussive and rotary motions of the Auto-Gopher. The percussive mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) mechanism that is driven by piezoelectric stack and that was demonstrated to require low axial preload. The design and fabrication of this device were presented in previous publications. This paper presents the results of laboratory and field tests and lessons learned from this development.

  5. Percussion hemoglobinuria - a novel term for hand trauma-induced mechanical hemolysis: a case report

    Directory of Open Access Journals (Sweden)

    Hariharan Sundaram

    2011-10-01

    Full Text Available Abstract Introduction Extracorpuscular hemolysis caused by mechanical trauma has been well described in relation to lower extremity use, such as in soldiers and runners. Terms such as "march hemoglobinuria", "foot strike hemolysis" and "runners hemoglobinuria" have previously been coined and are easily recalled. Newer cases, however, are being identified in individuals vigorously using their upper extremities, such as drum players who use their hands to strike the instrument. Given the increased recognition of upper extremity-related mechanical hemolysis and hemoglobinuria in drummers, and the use of hand drumming worldwide, we would like introduce a novel term for this condition and call it "percussion hemoglobinuria". Case presentation A 24-year-old Caucasian man presented with reddish brown discoloration of his urine after playing the djembe drum. Urine examination after a rigorous practice session revealed blood on the dipstick, and 0 to 2 red blood cells per high power field microscopically. The urine sample was negative for myoglobulin. Other causes of hemolysis and hematuria were excluded and cessation of drum playing resulted in resolution of his symptoms. Conclusions The association of mechanical trauma-induced hemoglobinuria and playing hand percussion instruments is increasingly being recognized. We, however, feel that the true prevalence is higher than what has been previously recorded in the literature. By coining the term "percussion hemoglobinuria" we hope to raise the awareness of screening for upper extremity trauma-induced mechanical hemolysis in the evaluation of a patient with hemoglobinuria.

  6. Development of automated blender and dispensing system

    International Nuclear Information System (INIS)

    Kulkarni, Anupama; Aherwal, P.; Patil, C.B.

    2014-01-01

    This paper describes automated blender and dispensing system designed and developed in Nuclear Recycle Board for its reprocessing plant. Obtaining sinterable grade oxide powder from the product solution received in the heavy metal product line involves skilled manpower and time consuming, laborious manual operations. Entire treatment is carried out in a train of closed containments called as glove boxes. In view of this Automated blender and dispensing system has been developed to reduce tedious manual operations. System consists of PLC based control system to drive motorised charging mechanism, a conical ribbon blender which homogenises the product and load cell triggered, indexing dispensing mechanism. Schematic design of the system has been done in-house, while fabrication was outsourced. System has been built, tested and installed at component test facility (CTF) at Tarapur. Actual blending tests were carried out by using dummy material like calcium carbonate and barium carbonate powder, with different sets of parameter. Blended product was chemically analysed for its homogeneity. System has now been put to trial runs by operating staff. This development has circumvented tedious operations of Scooping and increased the throughput. This paper describes challenges in undertaking this developmental work. (author)

  7. A Simulated Learning Environment for Teaching Medicine Dispensing Skills.

    Science.gov (United States)

    McDowell, Jenny; Styles, Kim; Sewell, Keith; Trinder, Peta; Marriott, Jennifer; Maher, Sheryl; Naidu, Som

    2016-02-25

    To develop an authentic simulation of the professional practice dispensary context for students to develop their dispensing skills in a risk-free environment. A development team used an Agile software development method to create MyDispense, a web-based simulation. Modeled on virtual learning environments elements, the software employed widely available standards-based technologies to create a virtual community pharmacy environment. Assessment. First-year pharmacy students who used the software in their tutorials, were, at the end of the second semester, surveyed on their prior dispensing experience and their perceptions of MyDispense as a tool to learn dispensing skills. The dispensary simulation is an effective tool for helping students develop dispensing competency and knowledge in a safe environment.

  8. Prescription, dispensation and marketing patterns of methylphenidate

    Directory of Open Access Journals (Sweden)

    Edson Perini

    2014-12-01

    Full Text Available OBJECTIVE To analyze the patterns and legal requirements of methylphenidate consumption. METHODS We conducted a cross-sectional study of the data from prescription notification forms and balance lists of drugs sales – psychoactive and others – subject to special control in the fifth largest city of Brazil, in 2006. We determined the defined and prescribed daily doses, the average prescription and dispensation periods, and the regional sales distribution in the municipality. In addition, we estimated the costs of drug acquisition and analyzed the individual drug consumption profile using the Lorenz curve. RESULTS The balance lists data covered all notified sales of the drug while data from prescription notification forms covered 50.6% of the pharmacies that sold it, including those with the highest sales volumes. Total methylphenidate consumption was 0.37 DDD/1,000 inhabitants/day. Sales were concentrated in more developed areas, and regular-release tablets were the most commonly prescribed pharmaceutical formulation. In some regions of the city, approximately 20.0% of the prescriptions and dispensation exceeded 30 mg/day and 30 days of treatment. CONCLUSIONS Methylphenidate was widely consumed in the municipality and mainly in the most developed areas. Of note, the consumption of formulations with the higher abuse risk was the most predominant. Both its prescription and dispensation contrasted with current pharmacotherapeutic recommendations and legal requirements. Therefore, the commercialization of methylphenidate should be monitored more closely, and its use in the treatment of behavioral changes of psychological disorders needs to be discussed in detail, in line with the concepts of the quality use of medicines.

  9. The evolution and cultural transmission of percussive technology: integrating evidence from palaeoanthropology and primatology.

    Science.gov (United States)

    Whiten, Andrew; Schick, Kathy; Toth, Nicholas

    2009-10-01

    We bring together the quite different kinds of evidence available from palaeoanthropology and primatology to better understand the origins of Plio-Pleistocene percussive technology. Accumulated palaeoanthropological discoveries now document the Oldowan Complex as the dominant stone tool making culture between 2.6-1.4 Ma, the earlier part of this contemporaneous with pre-Homo hominins. The principal types of artefacts and other remains from 20 Early Stone Age (Oldowan and earliest Acheulean) localities in Africa and elsewhere are reviewed and described. To better understand the ancestral behavioural foundations of this early lithic culture, we examine a range of recent findings from primatology. In particular, we attempt to identify key shared characteristics of Homo and Pan that support inferences about the preparedness of our common ancestor for the innovation of stone tool culture. Findings of particular relevance include: (i) the discovery of an expanding repertoire of percussive and other tool use based on directed use of force among wild chimpanzees, implicating capacities that include significant innovatory potential and appreciation of relevant causal factors; (ii) evidence of material cultural diversity among wild chimpanzees, indicating a readiness to acquire and transmit tool use innovations; and (iii) experimental studies of social learning in chimpanzees and bonobos that now encompass the acquisition of nut cracking through observation of skilled use of hammers and anvils by conspecifics, the diffusion within and between groups of alternative styles of tool use, and the adoption of free-hand stone-to-stone percussion to create useful flakes for cutting to gain access to food resources. We use the distributions of the inferred cultural traits in the wild to assess how diffusion relates to geographic distances, and find that shared traits drop by 50% from the approximately eight characteristic of close neighbours over a distance of approximately 700 km

  10. percussions des TIC sur la démocratie locale : transparence et ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    percussions des TIC sur la démocratie locale : transparence et participation des citoyens dans la municipalité de Peñalolén (au Chili). La municipalité de Peñalolén, établie en périphérie de Santiago, au Chili, se caractérise par sa grande diversité socioéconomique et par ses solides réseaux sociaux (clubs réservés aux ...

  11. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    Science.gov (United States)

    de Vos, Marc; Torah, Russel; Tudor, John

    2016-04-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.

  12. Structure Design and Realization of Rapid Medicine Dispensing System

    Science.gov (United States)

    Liu, Xiangquan

    In this paper, the main components and function of rapid medicine dispensing system is analyzed, structure design of automatic feeding device, sloping storeroom, automatic dispensing device and automatic sorting device is completed. The system adopts medicine conveyer working in with manipulator to realize automatic batch supply of the boxed medicine, adopts sloping storeroom as warehouse of medicine to realize dense depositing, adopts dispensing mechanism which includes elevator, turning panel and electric magnet to realize rapid medicine dispensing, adopts sorting conveyor belt and sorting device to send medicine to designated outlet.

  13. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2500... a mechanical device intended for medical purposes to dispense or serially dilute very small...

  14. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    International Nuclear Information System (INIS)

    De Vos, Marc; Torah, Russel; Tudor, John

    2016-01-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps. (paper)

  15. Catalogue of Wind and Percussion Solos and Ensembles and Recordings. American School Band Directors' Association, Research Committee Reports for the 26th Annual Convention, Oklahoma City, Oklahoma, 1978.

    Science.gov (United States)

    Berndt, William; Berndt, Arnold

    This catalogue lists over 350 phonograph records which feature solo and ensemble music by wind and percussion instruments. Instruments heard on the records include oboe/English horn, flute, clarinet, bassoon, trumpet/cornet, French horn, trombone, baritone, tuba, saxophone, percussion, woodwind ensembles, and brass ensembles. The catalogue is…

  16. Experimental studies illuminate the cultural transmission of percussive technologies in Homo and Pan.

    Science.gov (United States)

    Whiten, Andrew

    2015-11-19

    The complexity of Stone Age tool-making is assumed to have relied upon cultural transmission, but direct evidence is lacking. This paper reviews evidence bearing on this question provided through five related empirical perspectives. Controlled experimental studies offer special power in identifying and dissecting social learning into its diverse component forms, such as imitation and emulation. The first approach focuses on experimental studies that have discriminated social learning processes in nut-cracking by chimpanzees. Second come experiments that have identified and dissected the processes of cultural transmission involved in a variety of other force-based forms of chimpanzee tool use. A third perspective is provided by field studies that have revealed a range of forms of forceful, targeted tool use by chimpanzees, that set percussion in its broader cognitive context. Fourth are experimental studies of the development of flint knapping to make functional sharp flakes by bonobos, implicating and defining the social learning and innovation involved. Finally, new and substantial experiments compare what different social learning processes, from observational learning to teaching, afford good quality human flake and biface manufacture. Together these complementary approaches begin to delineate the social learning processes necessary to percussive technologies within the Pan-Homo clade. © 2015 The Author(s).

  17. Variability in an early hominin percussive tradition: the Acheulean versus cultural variation in modern chimpanzee artefacts.

    Science.gov (United States)

    Gowlett, J A J

    2015-11-19

    Percussion makes a vital link between the activities of early human ancestors and other animals in tool-use and tool-making. Far more of the early human actions are preserved as archaeology, since the percussion was largely used for making hard tools of stone, rather than for direct access to food. Both primate tools and early hominin tools, however, offer a means to exploring variability in material culture, a strong focus of interest in recent primate studies. This paper charts such variability in the Acheulean, the longest-lasting tool tradition, extant form about 1.7 to about 0.1 Ma, and well known for its characteristic handaxes. The paper concentrates on the African record, although the Acheulean was also known in Europe and Asia. It uses principal components and discriminant analysis to examine the measurements from 66 assemblages (whole toolkits), and from 18 sets of handaxes. Its review of evidence confirms that there is deep-seated pattern in the variation, with variability within a site complex often matching or exceeding that between sites far distant in space and time. Current techniques of study allow comparisons of handaxes far more easily than for other components, stressing a need to develop common practice in measurement and analysis. The data suggest, however, that a higher proportion of traits recurs widely in Acheulean toolkits than in the chimpanzee record. © 2015 The Author(s).

  18. Bronquiectasia e fisioterapia desobstrutiva: ênfase em drenagem postural e percussão Bronchiectasis and clearence physiotherapy: emphasis in postural drainage and percussion

    Directory of Open Access Journals (Sweden)

    Neuseli Marino Lamari

    2006-06-01

    Full Text Available Bronquiectasia consiste em dilatação anormal, permanente e irreversível de brônquios e bronquíolos, com infecções recorrentes, inflamações, hipersecreção e redução da limpeza mucociliar. Acomete predominantemente o sexo feminino, entre 28 e 48 anos de idade e afeta com maior freqüência os lobos inferiores bilateralmente. Manifestações clínicas da doença são a tosse crônica, febre e expectoração volumosa, purulenta, com odor fétido. Etiologia é inespecífica e representada pelo estádio final de diversos processos patológicos. Pode ser classificada em cilíndrica, varicosa e sacular, e ainda, em localizada e multissegmentar. Drenagem postural e percussão são técnicas desobstrutivas usuais na prática clínica diária, no entanto, há escassez de estudos comparativos enfatizando-as com amostras populacionais e recursos metodológicos. Tomando por base as considerações, teve-se como objetivo verificar a eficácia da drenagem postural e da percussão na higiene brônquica de pacientes bronquiectásicos, bem como seus efeitos e associação com outras técnicas apontadas pela literatura atual. Os principais achados comprovaram que a drenagem postural e a percussão são efetivas na mobilização da secreção pulmonar, uma vez que aumentam a velocidade do muco transportado, melhoram a função pulmonar e as trocas gasosas. A efetividade requer ajuda de um profissional, o que pode dificultar a prática clínica diária. Por esta razão, fisioterapeutas têm selecionado técnicas que propiciem independência ao paciente.Bronchiectasis consists of abnormal, permanent and irreversible dilation of bronchi and bronchia, with recurrent infections, inflammation, hypersecretion and reduction of mucus clearance. It predominantly affects women of between 28 and 48 years old and more frequently affects the inferior lobes. Clinical manifestations are chronic cough, fever and voluminous expectoration, with a fetid odor. The etiology

  19. Evaluation and remediation of bulk soap dispensers for biofilm.

    Science.gov (United States)

    Lorenz, Lindsey A; Ramsay, Bradley D; Goeres, Darla M; Fields, Matthew W; Zapka, Carrie A; Macinga, David R

    2012-01-01

    Recent studies evaluating bulk soap in public restroom soap dispensers have demonstrated up to 25% of open refillable bulk-soap dispensers were contaminated with ~ 6 log(10)(CFU ml(-1)) heterotrophic bacteria. In this study, plastic counter-mounted, plastic wall-mounted and stainless steel wall-mounted dispensers were analyzed for suspended and biofilm bacteria using total cell and viable plate counts. Independent of dispenser type or construction material, the bulk soap was contaminated with 4-7 log(10)(CFU ml(-1)) bacteria, while 4-6 log(10)(CFU cm(-2)) biofilm bacteria were isolated from the inside surfaces of the dispensers (n = 6). Dispenser remediation studies, including a 10 min soak with 5000 mg l(-1) sodium hypochlorite, were then conducted to determine the efficacy of cleaning and disinfectant procedures against established biofilms. The testing showed that contamination of the bulk soap returned to pre-test levels within 7-14 days. These results demonstrate biofilm is present in contaminated bulk-soap dispensers and remediation studies to clean and sanitize the dispensers are temporary.

  20. Impact of Robotic Dispensing Machines in German Pharmacies on ...

    African Journals Online (AJOL)

    To assess the impact of robotic dispensing machines in community pharmacies on staff efficiency and sales of over-the-counter drugs. Setting: The study was done on 253 community pharmacies in Germany that use a robotic dispensing machine manufactured by ROWA during 2008. Method: Data concerning the financial ...

  1. Anthelmintic drug dispensing in South Africa: An analysis of ...

    African Journals Online (AJOL)

    More than two billion people worldwide are infected with helminths. The primary aim of the study was to evaluate the dispensing patterns of anthelmintic products using dispensing data of South African community pharmacies. A retrospective, cross-sectional drug utilisation study was conducted on a 2013 community ...

  2. 14 CFR 137.39 - Economic poison dispensing.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Economic poison dispensing. 137.39 Section... AIRCRAFT OPERATIONS Operating Rules § 137.39 Economic poison dispensing. (a) Except as provided in... economic poison that is registered with the U.S. Department of Agriculture under the Federal Insecticide...

  3. Trends in radiopharmaceutical dispensing in a regional nuclear pharmacy

    International Nuclear Information System (INIS)

    Basmadjian, G.P.; Johnston, J.; Barker, K.; Ice, R.D.

    1982-01-01

    Dispensing trends for radiopharmaceuticals at a regional nuclear pharmacy over a 51-month period were studied. dispensing records of a regional nuclear pharmacy were analyzed with a forecasting procedure that uses univariate time data to produce time trends and autoregressive models. The overall number of prescriptions increased from 3500 to 5500 per quarter. Radiopharmaceuticals used in nuclear cardiology studies increased from less than 0.1% to 17.5% of total prescriptions dispensed, while radiopharmaceuticals used for brain imaging showed a steady decline from 29% to 11% of total prescriptions dispensed. The demand for other radiopharmaceuticals increased in areas such as renal studies, bone studies, lung studies, liver-function studies, and 67 Ga tumor-uptake studies, and declined slightly for static liver studies. Changes in dispensing trends for radiopharmaceuticals will continue as the practice of nuclear medicine concentrates more on functional studies and as newer imaging techniques become used for other purposes

  4. Deep Drilling and Sampling via the Wireline Auto-Gopher Driven by Piezoelectric Percussive Actuator and EM Rotary Motor

    Science.gov (United States)

    Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart; Zacny, Kris; Paulsen, Gale L; Beegle, Luther; Bao, Xiaoqi

    2012-01-01

    The ability to penetrate subsurfaces and perform sample acquisition at depths of meters is critical for future NASA in-situ exploration missions to bodies in the solar system, including Mars and Europa. A corer/sampler was developed with the goal of acquiring pristine samples by reaching depths on Mars beyond the oxidized and sterilized zone. To developed rotary-hammering coring drill, called Auto-Gopher, employs a piezoelectric actuated percussive mechanism for breaking formations and an electric motor rotates the bit to remove the powdered cuttings. This sampler is a wireline mechanism that is incorporated with an inchworm mechanism allowing thru cyclic coring and core removal to reach great depths. The penetration rate is being optimized by simultaneously activating the percussive and rotary motions of the Auto-Gopher. The percussive mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) mechanism that is driven by piezoelectric stack and that was demonstrated to require low axial preload. The Auto-Gopher has been produced taking into account the a lessons learned from the development of the Ultrasonic/Sonic Gopher that was designed as a percussive ice drill and was demonstrated in Antarctica in 2005 to reach about 2 meters deep. A field demonstration of the Auto-Gopher is currently being planned with objective of reaching as deep as 3 to 5 meters in tufa subsurface.

  5. Adaptation aux répercussions de l'élévation du niveau de la mer ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    , la pollution, l'utilisation intensive des terres, la croissance démographique et la dégradation des écosystèmes. Elles sont par ailleurs exposées aux répercussions de la hausse du niveau de la mer et notamment aux inondations. Réduire la ...

  6. Self-cleaning effect in high quality percussion ablating of cooling hole by picosecond ultra-short pulse laser

    Science.gov (United States)

    Zhao, Wanqin; Yu, Zhishui

    2018-06-01

    Comparing with the trepanning technology, cooling hole could be processed based on the percussion drilling with higher processing efficiency. However, it is widely believed that the ablating precision of hole is lower for percussion drilling than for trepanning, wherein, the melting spatter materials around the hole surface and the recast layer inside the hole are the two main issues for reducing the ablating precision of hole, especially for the recast layer, it can't be eliminated completely even through the trepanning technology. In this paper, the self-cleaning effect which is a particular property just for percussion ablating of holes has been presented in detail. In addition, the reasons inducing the self-cleaning effect have been discussed. At last, based on the self-cleaning effect of percussion drilling, high quality cooling hole without the melting spatter materials around the hole surface and recast layer inside the hole could be ablated in nickel-based superalloy by picosecond ultra-short pulse laser.

  7. Diastolic timed Vibro-Percussion at 50 Hz delivered across a chest wall sized meat barrier enhances clot dissolution and remotely administered Streptokinase effectiveness in an in-vitro model of acute coronary thrombosis

    Directory of Open Access Journals (Sweden)

    Hoffmann Andrew

    2012-11-01

    Full Text Available Abstract Background Low Frequency Vibro-Percussion (LFVP assists clearance of thrombi in catheter systems and when applied to the heart and timed to diastole is known to enhance coronary flow. However LFVP on a clotted coronary like vessel given engagement over a chest wall sized barrier (to resemble non-invasive heart attack therapy requires study. Methods One hour old clots (n=16 were dispensed within a flexible segment of Soft-Flo catheter (4 mm lumen, weighted, interfaced with Heparinized Saline (HS, secured atop a curved dampening base, and photographed. A ~4 cm meat slab was placed over the segment and randomized to receive intermittent LFVP (engaged, - disengaged at 1 second intervals, or no LFVP for 20 minutes. HS was pulsed (~120/80 mmHg, with the diastolic phase coordinated to match LFVP delivery. The segment was then re-photographed and aspirated of fluid to determine post clot weight. The trial was then repeated with 0.5 mls of Streptokinase (15,000 IU/100 microlitre delivered ~ 2 cm upstream from the clot. Results LFVP - HS only samples (vs. controls showed; a development of clot length fluid channels absent in the control group (p Conclusion Diastolic timed LFVP (50 Hz engaged across a chest wall sized barrier enhances clot disruptive effects to an underlying coronary like system.

  8. Application of basic pharmacology and dispensing practice of antibiotics in accredited drug-dispensing outlets in Tanzania

    Directory of Open Access Journals (Sweden)

    Minzi OM

    2013-01-01

    Full Text Available OM Minzi,1 VS Manyilizu21Unit of Pharmacology and Therapeutics, School of Pharmacy, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania, 2Logistics System Strengthening Unit, John Snow Inc, Dar es Salaam, TanzaniaBackground: Provision of pharmaceutical services in accredited drug-dispensing outlets (ADDOs in Tanzania has not been reported. This study compared the antibiotics dispensing practice between ADDOs and part II shops, or duka la dawa baridi (DLDBs, in Tanzania.Methodology: This was a cross-sectional study that was conducted in ADDOs and DLDBs. A simulated client method for data collection was used, and a total of 85 ADDOs, located in Mvomero, Kilombero, and Morogoro rural districts, were compared with 60 DLDBs located in Kibaha district. The research assistants posed as simulated clients and requested to buy antibiotics from ADDOs and DLDBs after presenting a case scenario or disease condition. Among the diseases presented were those requiring antibiotics and those usually managed only by oral rehydration salt or analgesics. The simulated clients wanted to know the antibiotics that were available at the shop. The posed questions set a convincing ground to the dispenser either to dispense the antibiotic directly, request a prescription, or refer the patient to a health facility. Proportions were used to summarize categorical variables between ADDOs and DLDBs, and the chi-square test was used to test for statistical difference between the two drug-outlet types in terms of antibiotic-dispensing practice.Results: As many as 40% of trained ADDO dispensers no longer worked at the ADDO shops, so some of the shops employed untrained staff. A larger proportion of ADDOs than DLDBs dispensed antibiotics without prescriptions (P = 0.004. The overall results indicate that there was no difference between the two types of shops in terms of adhering to regulations for dispensing antibiotics. However, in some circumstances, eg

  9. Application of vibratory-percussion crusher for disintegration of supertough materials

    Science.gov (United States)

    Shishkin, E. V.; Kazakov, S. V.

    2017-10-01

    This article describes the results of theoretical and experimental studies of a vibratory-percussion crusher, which is driven from a pair of self-synchronizing vibration exciters, attached to the shell symmetrically about its vertical axis. In addition to that, crusher’s dynamic model is symmetrical and balanced. Forced oscillation laws for crusher working members and their amplitude-frequency characteristics have been inducted. Domains of existence of synchronous opposite-phase oscillations of crusher working members (crusher’s operating mode) and crusher capabilities have been identified. The results of mechanical and technological tests of a pilot crusher presented in the article show that this crusher may be viewed as an advanced machine for disintegration of supertough materials with minimum regrinding of finished products.

  10. 4,300-year-old chimpanzee sites and the origins of percussive stone technology.

    Science.gov (United States)

    Mercader, Julio; Barton, Huw; Gillespie, Jason; Harris, Jack; Kuhn, Steven; Tyler, Robert; Boesch, Christophe

    2007-02-27

    Archaeological research in the African rainforest reveals unexpected results in the search for the origins of hominoid technology. The ancient Panin sites from Côte d'Ivoire constitute the only evidence of prehistoric ape behavior known to date anywhere in the world. Recent archaeological work has yielded behaviorally modified stones, dated by chronometric means to 4,300 years of age, lodging starch residue suggestive of prehistoric dietary practices by ancient chimpanzees. The "Chimpanzee Stone Age" pre-dates the advent of settled farming villages in this part of the African rainforest and suggests that percussive material culture could have been inherited from an common human-chimpanzee clade, rather than invented by hominins, or have arisen by imitation, or resulted from independent technological convergence.

  11. Rhythm histograms and musical meter: A corpus study of Malian percussion music.

    Science.gov (United States)

    London, Justin; Polak, Rainer; Jacoby, Nori

    2017-04-01

    Studies of musical corpora have given empirical grounding to the various features that characterize particular musical styles and genres. Palmer & Krumhansl (1990) found that in Western classical music the likeliest places for a note to occur are the most strongly accented beats in a measure, and this was also found in subsequent studies using both Western classical and folk music corpora (Huron & Ommen, 2006; Temperley, 2010). We present a rhythmic analysis of a corpus of 15 performances of percussion music from Bamako, Mali. In our corpus, the relative frequency of note onsets in a given metrical position does not correspond to patterns of metrical accent, though there is a stable relationship between onset frequency and metrical position. The implications of this non-congruence between simple statistical likelihood and metrical structure for the ways in which meter and metrical accent may be learned and understood are discussed, along with importance of cross-cultural studies for psychological research.

  12. Development of an Automatic Dispensing System for Traditional Chinese Herbs

    Directory of Open Access Journals (Sweden)

    Chi-Ying Lin

    2017-01-01

    Full Text Available The gathering of ingredients for decoctions of traditional Chinese herbs still relies on manual dispensation, due to the irregular shape of many items and inconsistencies in weights. In this study, we developed an automatic dispensing system for Chinese herbal decoctions with the aim of reducing manpower costs and the risk of mistakes. We employed machine vision in conjunction with a robot manipulator to facilitate the grasping of ingredients. The name and formulation of the decoction are input via a human-computer interface, and the dispensing of multiple medicine packets is performed automatically. An off-line least-squared curve fitting method was used to calculate the amount of material grasped by the claws and thereby improve system efficiency as well as the accuracy of individual dosages. Experiments on the dispensing of actual ingredients demonstrate the feasibility of the proposed system.

  13. Drug dispensing errors in a ward stock system

    DEFF Research Database (Denmark)

    Andersen, Stig Ejdrup

    2010-01-01

    . Multivariable analysis showed that surgical and psychiatric settings were more susceptible to involvement in dispensing errors and that polypharmacy was a risk factor. In this ward stock system, dispensing errors are relatively common, they depend on speciality and are associated with polypharmacy......The aim of this study was to determine the frequency of drug dispensing errors in a traditional ward stock system operated by nurses and to investigate the effect of potential contributing factors. This was a descriptive study conducted in a teaching hospital from January 2005 to June 2007. In five....... These results indicate that strategies to reduce dispensing errors should address polypharmacy and focus on high-risk units. This should, however, be substantiated by a future trial....

  14. Foreign private capital inflows in Nigeria's democratic dispensation ...

    African Journals Online (AJOL)

    FPCI) in Nigeria in the current democratic dispensation with a view to finding out whether the inflows have recorded significant increase since the institution of Democracy in the country. Relevant theories and empirical data were reviewed.

  15. Determinants of Dispensing Location in the TRICARE Senior Pharmacy Program

    Science.gov (United States)

    2005-01-01

    proximity to an MTF on TSRx use and on uti - lization of the different dispensing locations; and the impact of MTF formulary restrictions on use of the...Conclusions and Policy Implications Our analysis of the TSRx program, which focused on describing uti - lization patterns by dispensing location and on...manufacturers do. In the public sector, some Medicaid programs have recently hired physicians and pharmacists to visit doctors’ offices and encourage them to

  16. 46 CFR 105.90-1 - Existing commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Existing commercial fishing vessels dispensing petroleum... AND MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Existing Commercial Fishing Vessels Dispensing Petroleum Products § 105.90-1 Existing commercial fishing vessels dispensing...

  17. Recent advances in inkjet dispensing technologies: applications in drug discovery.

    Science.gov (United States)

    Zhu, Xiangcheng; Zheng, Qiang; Yang, Hu; Cai, Jin; Huang, Lei; Duan, Yanwen; Xu, Zhinan; Cen, Peilin

    2012-09-01

    Inkjet dispensing technology is a promising fabrication methodology widely applied in drug discovery. The automated programmable characteristics and high-throughput efficiency makes this approach potentially very useful in miniaturizing the design patterns for assays and drug screening. Various custom-made inkjet dispensing systems as well as specialized bio-ink and substrates have been developed and applied to fulfill the increasing demands of basic drug discovery studies. The incorporation of other modern technologies has further exploited the potential of inkjet dispensing technology in drug discovery and development. This paper reviews and discusses the recent developments and practical applications of inkjet dispensing technology in several areas of drug discovery and development including fundamental assays of cells and proteins, microarrays, biosensors, tissue engineering, basic biological and pharmaceutical studies. Progression in a number of areas of research including biomaterials, inkjet mechanical systems and modern analytical techniques as well as the exploration and accumulation of profound biological knowledge has enabled different inkjet dispensing technologies to be developed and adapted for high-throughput pattern fabrication and miniaturization. This in turn presents a great opportunity to propel inkjet dispensing technology into drug discovery.

  18. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  19. ["... my friend Leopold was percussing her through her bodice...". Leopold von Auenbrugger in Sigmund Freud's dream of Irma's injection].

    Science.gov (United States)

    Reicheneder, Johann Georg

    2011-01-01

    This paper provides a psychoanalytic interpretation of an element in the Irma dream that Freud had ignored in his own interpretation. The allusion to Leopold von Auenbrugger, the originator of percussion as a method of clinical investigation, which appears in the manifest dream reflects Freud's hopes and fears about how his Interpretation of Dreams and the new human science established there would be received by his medical colleagues.

  20. DE-FOA-EE0005502 Advanced Percussive Drilling Technology for Geothermal Exploration and Development Phase II Report.

    Energy Technology Data Exchange (ETDEWEB)

    Su, Jiann-Cherng [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Raymond, David W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Prasad, Somuri V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wolfer, Dale R. [Atlas-Copco Secoroc, LLC, Fagersta (Sweden)

    2017-05-01

    Percussive hammers are a promising advance in drilling technology for geothermal since they rely upon rock reduction mechanisms that are well-suited for use in the hard, brittle rock characteristic of geothermal formations. The project research approach and work plan includes a critical path to development of a high-temperature (HT) percussive hammer using a two- phase approach. The work completed in Phase I of the project demonstrated the viability of percussive hammers and that solutions to technical challenges in design, material technology, and performance are likely to be resolved. Work completed in Phase II focused on testing the findings from Phase I and evaluating performance of the materials and designs at high- operating temperatures. A high-operating temperature (HOT) drilling facility was designed, built, and used to test the performance of the DTH under extreme conditions. Results from the testing indicate that a high-temperature capable hammer can be developed and is a viable alternative for user in the driller's toolbox.

  1. Slow Release of Plant Volatiles Using Sol-Gel Dispensers.

    Science.gov (United States)

    Bian, L; Sun, X L; Cai, X M; Chen, Z M

    2014-12-01

    The black citrus aphid, also known as the tea aphid, (Toxoptera aurantii Boyer) attacks economically important crops, including tea (Camellia sinensis (L.) O. Kuntze). In the current study, silica sol-gel formulations were screened to find one that could carry and release C. sinensis plant volatiles to lure black citrus aphids in a greenhouse. The common plant volatile trans-2-hexen-1-al was used as a model molecule to screen for suitable sol-gel formulations. A zNose (Electronic Sensor Technology, Newbury Park, CA) transportable gas chromatograph was used to continuously monitor the volatile emissions. A sol-gel formulation containing tetramethyl orthosilicate and methyltrimethoxysilane in an 8:2 (vol:vol) ratio was selected to develop a slow-release dispenser. The half-life of trans-2-hexen-1-al in the sol-gel dispenser increased slightly with the volume of this compound in the dispenser. Ten different volatiles were tested in the sol-gel dispenser. Alcohols of 6-10 carbons had the longest half-lives (3.01-3.77 d), while esters of 6-12 carbons had the shortest (1.53-2.28 d). Release of these volatiles from the dispensers could not be detected by the zNose after 16 d (cis-3-hexenyl acetate) to 26 d (3,7-dimethylocta-1,6-dien-3-ol). In greenhouse experiments, trans-2-hexen-1-al and cis-3-hexen-1-ol released from the sol-gel dispensers attracted aphids for ≍17 d, and release of these volatiles could not be detected by the zNose after ≍24 d. The sol-gel dispensers performed adequately for the slow release of plant volatiles to trap aphids in the greenhouse. © 2014 Entomological Society of America.

  2. Modeling for pipe decontamination by means of high-frequency percussive action; Modellerstellung fuer die Rohrdekontamination mittels hochfrequenter Schlagwirkung

    Energy Technology Data Exchange (ETDEWEB)

    Aminy, Akramullah

    2014-07-30

    The formation of persistent scales in pipes causes lower flow rates and therefore represents an economic problem. The contamination of scales - which usually is the case in most industrial applications - also poses a problem with respect to the scales' environmental compatibility. The currently applied techniques for the removal of these scales involve the use of auxiliary materials which accumulate large quantities of secondary waste that is costly to be disposed of. In this research, an environmentally friendly removal method for tubing scales was developed and qualified. The analysis of the currently used technologies formed the basis for the analysis and systematic evaluation of different principles of removal action methods. Consequently, a concept for a new impact based removal method was established. The mechanism of this technique is the application of a high-frequency percussive action by a geometrically defined tool. The impact on the scales cracks their surface and causes their fracture and thus the detachment from the pipes. Compared to alternative removal methods this proposed technique works without any auxiliary material and thus prevents the production of secondary waste. The investigation of the impact process was carried out in a newly developed test rig. In this test rig, the maximum forces of the percussive tool were measured with shear force sensors on the tubing surface and the resulting stress on the tube was obtained. The evaluation of the measured values using the method of descriptive statistics demonstrated that the high dynamic stress of the tubing due to the complex tool motion is based on a normal distribution. Based on this evaluation, the effects of the influencing factors on the stress of the tubings were systematically measured and outlined in a mathematical model. This model describes the dependency of the tool and the process of related factors that influences the tubing stress. According to this model, this stress is

  3. The K-1 Active Dispenser for Orbit Transfer

    Science.gov (United States)

    Lai, G.; Cochran, D.; Curtis, R.

    2002-01-01

    Kistler Aerospace Corporation is building the K-1, the world's first fully reusable launch vehicle. The two-stage K- 1 is designed primarily to service the market for low-earth orbit (LEO) missions, due to Kistler's need to recover both stages. For customers requiring payload delivery to high-energy orbits, Kistler can outfit the payload with a K- 1 Active Dispenser (an expendable third stage). The K-1 second stage will deploy the Active Dispenser mated with its payload into a 200 km circular LEO parking orbit. From this orbit, the Active Dispenser would use its own propulsion to place its payload into the final desired drop-off orbit or earth-escape trajectory. This approach allows Kistler to combine the low-cost launch services offered by the reusable two-stage K-1 with the versatility of a restartable, expendable upper stage. Enhanced with an Active Dispenser, the K-1 will be capable of delivering 1,500 kg to a geosynchronous transfer orbit or up to approximately 1,000 kg into a Mars rendezvous trajectory. The list price of a K-1 Active Dispenser launch is 25 million (plus the price of mission unique integration services) significantly less than the price of any launch vehicle service in the world with comparable capability.

  4. Characterization of rotary-percussion drilling as a seismic-while-drilling source

    Science.gov (United States)

    Xiao, Yingjian; Hurich, Charles; Butt, Stephen D.

    2018-04-01

    This paper focuses on an evaluation of rotary-percussion drilling (RPD) as a seismic source. Two field experiments were conducted to characterize seismic sources from different rocks with different strengths, i.e. weak shale and hard arkose. Characterization of RPD sources consist of spectral analysis and mean power measurements, along with field measurements of the source radiation patterns. Spectral analysis shows that increase of rock strength increases peak frequency and widens bandwidth, which makes harder rock more viable for seismic-while-drilling purposes. Mean power analysis infers higher magnitude of body waves in RPD than in conventional drillings. Within the horizontal plane, the observed P-wave energy radiation pattern partially confirms the theoretical radiation pattern under a single vertical bit vibration. However a horizontal lobe of energy is observed close to orthogonal to the axial bit vibration. From analysis, this lobe is attributed to lateral bit vibration, which is not documented elsewhere during RPD. Within the horizontal plane, the observed radiation pattern of P-waves is generally consistent with a spherically-symmetric distribution of energy. In addition, polarization analysis is conducted on P-waves recorded at surface geophones for understanding the particle motions. P-wave particle motions are predominantly in the vertical direction showing the interference of the free-surface.

  5. Time to Add a Fifth Pillar to Bedside Physical Examination: Inspection, Palpation, Percussion, Auscultation, and Insonation.

    Science.gov (United States)

    Narula, Jagat; Chandrashekhar, Y; Braunwald, Eugene

    2018-04-01

    Inspection, palpation, percussion, and auscultation have been the 4 pillars of clinical bedside medicine. Although these basic methods of physical examination have served us well, traditional bedside examination, for a number of reasons including diminishing interest and expertise, performs well less than what is required of a modern diagnostic strategy. Improving the performance of physical examination is vital given that it is crucial to guide diagnostic possibilities and further testing. Current efforts at improving physical examination skills during medical training have not been very successful, and incorporating appropriate technology at the bedside might improve its performance. Selective use of bedside ultrasound (or insonation) can be one such strategy that could be incorporated as the fifth component of the physical examination. Seeing pathology through imaging might improve interest in physical examination among trainees, and permit appropriate downstream testing and possibly superior decision making. Current ultrasound technology makes this feasible, and further miniaturization of ultrasound devices and reduced cost will allow for routine use at the bedside. It is time to have a wider debate and a possible consensus about updates required to enhance current paradigms of physical examination.

  6. Influence of intrapulmonary percussive ventilation in upright position on gastro-oesophageal reflux in infants.

    Science.gov (United States)

    Van Ginderdeuren, F; Kerckhofs, E; Deneyer, M; Vanlaethem, S; Buyl, R; Vandenplas, Y

    2016-10-01

    To determine the influence of physiotherapy using intrapulmonary percussive ventilation on gastro-oesophageal reflux (GOR) in infants reflux episodes (RE) over a 20-min period was registered for each infant and a mean per 20 min was calculated in order to obtain a baseline value. The number of RE during IPV R intervention was compared to baseline. Fifty infants with a median age of 133 days were recruited of whom 21 were diagnosed with pathological GOR. During IPV R , the incidence of RE in the entire group was significantly lower compared to baseline; median (inter-quartile range [IQR]) 0 (0-1) versus 0.71 (0-1.33) RE, respectively, P = 0.003. The subgroup with abnormal GOR showed also a significant decrease of RE during IPV R ; median (IQR) 0 (0-1) versus 1.17 (0.55-2.16) RE, respectively, P = 0.03. No difference was detected in the group with normal reflux; median (IQR) 0.6 (0-1) compared to 0 (0-1) RE, respectively, P = 0.34. IPV R does not induce, nor aggravate GOR in infants without and with pathological GOR, respectively, but on the contrary decreases the number of RE in patients with pathological reflux. Pediatr Pulmonol. 2016;51:1065-1071. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Using the centre of percussion to design a steering controller for an autonomous race car

    Science.gov (United States)

    Kritayakirana, Krisada; Gerdes, J. Christian

    2012-01-01

    Understanding how a race car driver controls a vehicle at its friction limits can provide insights into the development of vehicle safety systems. In this paper, a race car driver's behaviour inspires the design of an autonomous racing controller. The resulting controller uses the vehicle's centre of percussion (COP) to design feedforward and feedback steering. At the COP, the effects of rotation and translation from the rear tire force cancel each other out; consequently, the feedforward steering command is robust to the disturbances from the rear tire force. Using the COP also simplifies the equations of motion, as the vehicle's lateral motion is decoupled from the vehicle's yaw motion and highlights the challenge of controlling a vehicle when the rear tires are highly saturated. The resulting dynamics can be controlled with a linear state feedback based on a lane-keeping system with additional yaw damping. Utilising Lyapunov theory, the closed-loop system is shown to remain stable even when the rear tires are highly saturated. The experimental results demonstrate that an autonomous vehicle can operate at its limits while maintaining a minimal lateral error.

  8. How similar are nut-cracking and stone-flaking? A functional approach to percussive technology.

    Science.gov (United States)

    Bril, Blandine; Parry, Ross; Dietrich, Gilles

    2015-11-19

    Various authors have suggested similarities between tool use in early hominins and chimpanzees. This has been particularly evident in studies of nut-cracking which is considered to be the most complex skill exhibited by wild apes, and has also been interpreted as a precursor of more complex stone-flaking abilities. It has been argued that there is no major qualitative difference between what the chimpanzee does when he cracks a nut and what early hominins did when they detached a flake from a core. In this paper, similarities and differences between skills involved in stone-flaking and nut-cracking are explored through an experimental protocol with human subjects performing both tasks. We suggest that a 'functional' approach to percussive action, based on the distinction between functional parameters that characterize each task and parameters that characterize the agent's actions and movements, is a fruitful method for understanding those constraints which need to be mastered to perform each task successfully, and subsequently, the nature of skill involved in both tasks. © 2015 The Author(s).

  9. Effects of Exercise Following Lateral Fluid Percussion Brain Injury in Rats.

    Science.gov (United States)

    Hicks, Ramona R.; Boggs, Arden; Leider, Denise; Kraemer, Philip; Brown, Russell; Scheff, Stephen W.; Seroogy, Kim B.

    1998-01-01

    Previous studies have suggested that brain-derived neurotrophic factor (BDNF) is involved in memory and learning, and may be neuroprotective following various brain insults. Exercise has been found to increase BDNF mRNA levels in various brain regions, including specific subpopulations of hippocampal neurons. In the present study, we were interested in whether following traumatic brain injury, exercise could increase BDNF mRNA expression, attenuate neuropathology, and improve cognitive and neuromoter performance. We subjected adult male Sprague-Dawley rats to a fluid percussion brain injury, followed by either 18 days of treadmill exercise or handling. Spatial memory was evaluated in a Morris Water Maze (MWM) and motor function was evaluated with a battery of neuromotor tests. Neuropathology was evaluated by measuring the cortical lesion volume and the extent of neuronal loss in the hipocampus. Expression of BDNF mRNA in the hippocampus was assessed with in situ hybridization and densitometry. Hybridization signal for BDNF mRNA was significantly increased bilaterally in the exercise group in hippocampal regions CA1 and CA3 (p<0.05), but not in the granule cell layer of the dentate gyrus. No significant differences were observed between the groups in neuropathology, spatial memory, or motor performance. This study suggests that after traumatic brain injury, exercise elevates BDNF mRNA in specific regions of the hippocampus.

  10. The musical environment and auditory plasticity: Hearing the pitch of percussion

    Directory of Open Access Journals (Sweden)

    Neil M Mclachlan

    2013-10-01

    Full Text Available Although musical skills clearly improve with training, pitch processing has generally been believed to be biologically determined by the behavior of brain stem neural mechanisms. Two main classes of pitch models have emerged over the last 50 years. Harmonic template models have been used to explain cross-channel integration of frequency information, and waveform periodicity models have been used to explain pitch discrimination that is much finer than the resolution of the auditory nerve. It has been proposed that harmonic templates are learnt from repeated exposure to voice, and so it may also be possible to learn inharmonic templates from repeated exposure to inharmonic music instruments. This study investigated whether pitch-matching accuracy for inharmonic percussion instruments was better in people who have trained on these instruments and could reliably recognize their timbre. We found that adults who had trained with Indonesian gamelan instruments were better at recognizing and pitch-matching gamelan instruments than people with similar levels of music training, but no prior exposure to these instruments. These findings suggest that gamelan musicians were able to use inharmonic templates to support accurate pitch processing for these instruments. We suggest that recognition mechanisms based on spectrotemporal patterns of afferent auditory excitation in the early stages of pitch processing allow rapid priming of the lowest frequency partial of inharmonic timbres, explaining how music training can adapt pitch processing to different musical genres and instruments.

  11. Perspectives on object manipulation and action grammar for percussive actions in primates.

    Science.gov (United States)

    Hayashi, Misato

    2015-11-19

    The skill of object manipulation is a common feature of primates including humans, although there are species-typical patterns of manipulation. Object manipulation can be used as a comparative scale of cognitive development, focusing on its complexity. Nut cracking in chimpanzees has the highest hierarchical complexity of tool use reported in non-human primates. An analysis of the patterns of object manipulation in naive chimpanzees after nut-cracking demonstrations revealed the cause of difficulties in learning nut-cracking behaviour. Various types of behaviours exhibited within a nut-cracking context can be examined in terms of the application of problem-solving strategies, focusing on their basis in causal understanding or insightful intentionality. Captive chimpanzees also exhibit complex forms of combinatory manipulation, which is the precursor of tool use. A new notation system of object manipulation was invented to assess grammatical rules in manipulative actions. The notation system of action grammar enabled direct comparisons to be made between primates including humans in a variety of object-manipulation tasks, including percussive-tool use. © 2015 The Author(s).

  12. Reflections on the Body Percussion at the Municipal School Aleixo Pereira Braga II

    Directory of Open Access Journals (Sweden)

    José Donizete Pedrosa Gomes

    2016-03-01

    Full Text Available Why the ideas of discipline, rigidity, detachment between the educator and the educating still are so exalted in our society? Why are they still are directly associated with the learning? Are there no other ways of the learning happen and which may be more effective than this traditional models? These were the main concerns that guide us to elaborate this article. The group PET Conexão de Saberes - Música do Oprimido (Program of Tutorial Education/Connection of knowledge - Music of the Oppressed - UnB performed in the period from 16 May to 11 July 2015 body percussion workshops at the Municipal School Aleixo Pereira Braga II (Cidade Ocidental-GO. We lived with a group of kids during the Saturdays by the morning and realized that this musical activity began a dynamic environment of learning based on the collectivity, playfulness and affectivity. The children assimilate the workshops as plays and felt free to take risks, experiment and learn about music. Thus, this experience with children of Cidade Ocidental made us reflect about the role of the affectivity in the Child Education basing ourselves in articles of Developmental Psychology area and the Social-Emotional Education.

  13. Do Pregnant Women Report Use of Dispensed Medications?

    DEFF Research Database (Denmark)

    Olesen, Charlotte; Søndergaard, Charlotte; Thrane, Nana

    2001-01-01

    Surveillance of drug safety in pregnancy often draws on administrative prescription registries. Noncompliance in the use of prescribed medication may be frequent among pregnant women owing to their fear of fetotoxic side effects. To estimate compliance in the use of prescription drugs dispensed...... during pregnancy, we compared prescription data from the North Jutland Prescription Database with information on drug use provided by pregnant women to the Danish National Birth Cohort (DNBC), which is a health interview survey. We used the North Jutland Prescription Database to identify all prescription...... drugs dispensed during pregnancy for the 2,041 women who were enrolled in the DNBC in the County of North Jutland, Denmark. Compliance was defined as the probability of reporting drug use in DNBC after purchasing a dispensed prescription drug. The overall compliance to drugs purchased within 120 days...

  14. Volumetric dispenser for small particles from plural sources

    International Nuclear Information System (INIS)

    Bradley, R.A.; Miller, W.H.; Sease, J.D.

    1975-01-01

    Apparatus is described for rapidly and accurately dispensing measured volumes of small particles from a supply hopper. The apparatus includes an adjustable, vertically oriented measuring tube and orifice member defining the volume to be dispensed, a ball plug valve for selectively closing the bottom end of the orifice member, and a compression valve for selectively closing the top end of the measuring tube. A supply hopper is disposed above and in gravity flow communication with the measuring tube. Properly sequenced opening and closing of the two valves provides accurate volumetric discharge through the ball plug valve. A dispensing system is described wherein several appropriately sized measuring tubes, orifice members, and associated valves are arranged to operate contemporaneously to facilitate blending of different particles

  15. Plasma processes inside dispenser hollow cathodes

    International Nuclear Information System (INIS)

    Mikellides, Ioannis G.; Katz, Ira; Goebel, Dan M.; Polk, James E.; Jameson, Kristina K.

    2006-01-01

    A two-dimensional fluid model of the plasma and neutral gas inside dispenser orificed hollow cathodes has been developed to quantify plasma processes that ultimately determine the life of the porous emitters inserted in these devices. The model self-consistently accounts for electron emission from the insert as well as for electron and ion flux losses from the plasma. Two cathodes, which are distinctively different in size and operating conditions, have been simulated numerically. It is found that the larger cathode, with outer tube diameter of 1.5 cm and orifice diameter of 0.3 cm, establishes an effective emission zone that spans approximately the full length of the emitter when operated at a discharge current of 25 A and a flow rate of 5.5 sccm. The net heating of the emitter is caused by ions that are produced by ionization of the neutral gas inside the tube and are then accelerated by the sheath along the emitter. The smaller cathode, with an outer diameter of 0.635 cm and an orifice diameter of 0.1 cm, does not exhibit the same operational characteristics. At a flow rate of 4.25 sccm and discharge current of 12 A, the smaller cathode requires 4.5 times the current density near the orifice and operates with more than 6 times the neutral particle density compared to the large cathode. As a result, the plasma particle density is almost one order of magnitude higher compared to the large cathode. The plasma density in this small cathode is high enough such that the Debye length is sufficiently small to allow 'sheath funneling' into the pores of the emitter. By accessing areas deeper into the insert material, it is postulated that the overall emission of electrons is significantly enhanced. The maximum emission current density is found to be about 1 A/mm 2 in the small cathode, which is about one order of magnitude higher than attained in the large cathode. The effective emission zone in the small cathode extends to about 15% of the emitter length only, and the

  16. Dispensing of non-prescribed antibiotics in Jordan

    Directory of Open Access Journals (Sweden)

    Almaaytah A

    2015-09-01

    Full Text Available Ammar Almaaytah,1 Tareq L Mukattash,2 Julia Hajaj2 1Department of Pharmaceutical Technology, 2Department of Clinical Pharmacy, Faculty of Pharmacy, Jordan University of Science and Technology, Irbid, Jordan Objective: Current regulations in Jordan state that antibiotics cannot be sold without a medical prescription. This study aimed to assess the percentage of pharmacies that dispense antibiotics without a medical prescription in the Kingdom of Jordan and identify and highlight the extent and seriousness of such practices among Jordanian pharmacies. Methods: A prospective study was performed, and five different clinical scenarios were simulated at pharmacies investigated including sore throat, otitis media, acute sinusitis, diarrhea, and urinary tract infection in childbearing-aged women. Three levels of demand were used to convince the pharmacists to sell an antibiotic. Results: A total of 202 total pharmacies in Jordan were visited in the present study. The majority of pharmacies (74.3% dispensed antibiotics without prescription with three different levels of demand. The percentage of pharmacies dispensing antibiotics without a prescription for the sore throat scenario was 97.6%, followed by urinary tract infection (83.3%, diarrhea (83%, and otitis media (68.4%. The lowest percentage of antibiotic dispensing was for the acute sinusitis simulation at 48.5%. Among the pharmacies that dispensed antibiotics, the pharmacists provided an explanation as the number of times per day the drug should be taken in 95.3% of the cases, explained the duration of treatment in 25.7%, and inquired about allergies prior to the sale of the antibiotic in only 17.3%. Only 52 pharmacies (25.7% refused to dispense any kind of antibiotics, the majority (61.5% of this refusal response came from acute sinusitis cases, while the minority (2.4% came from the sore throat cases. Conclusion: The results of this study demonstrate that antibiotics continue to be dispensed

  17. Construction of a smart medication dispenser with high degree of scalability and remote manageability.

    Science.gov (United States)

    Pak, JuGeon; Park, KeeHyun

    2012-01-01

    We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT). In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.

  18. Construction of a Smart Medication Dispenser with High Degree of Scalability and Remote Manageability

    Directory of Open Access Journals (Sweden)

    JuGeon Pak

    2012-01-01

    Full Text Available We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT. In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.

  19. Analysis and Testing of Load Characteristics for Rotary-Percussive Drilling of Lunar Rock Simulant with a Lunar Regolith Coring Bit

    Directory of Open Access Journals (Sweden)

    Peng Li

    2017-01-01

    Full Text Available Based on an optimized lunar regolith coring bit (LRCB configuration, the load characteristics of rotary-percussive drilling of lunar rock simulant in a laboratory environment are analyzed to determine the effects of the drilling parameters (the rotational velocity, the penetration rate, and the percussion frequency on the drilling load. The process of rotary drilling into lunar rock using an LRCB is modeled as an interaction between an elemental blade and the rock. The rock’s fracture mechanism during different stages of the percussive mechanism is analyzed to create a load forecasting model for the cutting and percussive fracturing of rock using an elemental blade. Finally, a model of the load on the LRCB is obtained from the analytic equation for the bit’s cutting blade distribution; experimental verification of the rotary-impact load characteristics for lunar rock simulant with different parameters is performed. The results show that the penetrations per revolution (PPR are the primary parameter influencing the drilling load. When the PPR are fixed, increasing the percussion frequency reduces the drilling load on the rock. Additionally, the variation pattern of the drilling load of the bit is in agreement with that predicted by the theoretical model. This provides a research basis for subsequent optimization of the drilling procedure and online recognition of the drilling process.

  20. Astrocyte oxidative metabolism and metabolite trafficking after fluid percussion brain injury in adult rats.

    Science.gov (United States)

    Bartnik-Olson, Brenda L; Oyoyo, Udochukwu; Hovda, David A; Sutton, Richard L

    2010-12-01

    Despite various lines of evidence pointing to the compartmentation of metabolism within the brain, few studies have reported the effect of a traumatic brain injury (TBI) on neuronal and astrocyte compartments and/or metabolic trafficking between these cells. In this study we used ex vivo ¹³C NMR spectroscopy following an infusion of [1-¹³C] glucose and [1,2-¹³C₂] acetate to study oxidative metabolism in neurons and astrocytes of sham-operated and fluid percussion brain injured (FPI) rats at 1, 5, and 14 days post-surgery. FPI resulted in a decrease in the ¹³C glucose enrichment of glutamate in neurons in the injured hemisphere at day 1. In contrast, enrichment of glutamine in astrocytes from acetate was not significantly decreased at day 1. At day 5 the ¹³C enrichment of glutamate and glutamine from glucose in the injured hemisphere of FPI rats did not differ from sham levels, but glutamine derived from acetate metabolism in astrocytes was significantly increased. The ¹³C glucose enrichment of the C3 position of glutamate (C3) in neurons was significantly decreased ipsilateral to FPI at day 14, whereas the enrichment of glutamine in astrocytes had returned to sham levels at this time point. These findings indicate that the oxidative metabolism of glucose is reduced to a greater extent in neurons compared to astrocytes following a FPI. The increased utilization of acetate to synthesize glutamine, and the acetate enrichment of glutamate via the glutamate-glutamine cycle, suggests an integral protective role for astrocytes in maintaining metabolic function following TBI-induced impairments in glucose metabolism.

  1. High-frequency percussive ventilation attenuates lung injury in a rabbit model of gastric juice aspiration.

    Science.gov (United States)

    Allardet-Servent, Jérôme; Bregeon, Fabienne; Delpierre, Stéphane; Steinberg, Jean-Guillaume; Payan, Marie-José; Ravailhe, Sylvie; Papazian, Laurent

    2008-01-01

    To test the effects of high-frequency percussive ventilation (HFPV) compared with high-frequency oscillatory ventilation (HFOV) and low-volume conventional mechanical ventilation (LVCMV), on lung injury course in a gastric juice aspiration model. Prospective, randomized, controlled, in-vivo animal study. University animal research laboratory. Forty-three New Zealand rabbits. Lung injury was induced by intratracheal instillation of human gastric juice in order to achieve profound hypoxaemia (PaO2/FIO2ventilated for 4h after randomization in one of the following four groups: HFPV (median pressure 15cmH2O); LVCMV (VT 6mlkg(-1) and PEEP set to reach 15cmH2O plateau pressure); HFOV (mean pressure 15cmH2O); and a high-volume control group HVCMV (VT 12ml kg(-1) and ZEEP). Static respiratory compliance increased after the ventilation period in the HFPV, LVMCV and HFOV groups, in contrast with the HVCMV group. PaO2/FIO2 improved similarly in the HFPV, LVCMV and HFOV groups, and remained lower in the HVCMV group than in the three others. Lung oedema, myeloperoxidase and histological lung injury score were higher in the HVCMV group, but not different among all others. Arterial lactate markedly increased after 4h of ventilation in the HVCMV group, while lower but similar levels were observed in the three other groups. HFPV, like HFOV and protective CMV, improves respiratory mechanics and oxygenation, and attenuates lung damage. The HFPV provides attractive lung protection, but further studies should confirm these results before introducing HFPV into the clinical arena.

  2. Site investigation SFR. Boremap mapping of percussion drilled borehole HFR106

    Energy Technology Data Exchange (ETDEWEB)

    Winell, Sofia (Geosigma AB (Sweden))

    2010-06-15

    This report presents the result from the Boremap mapping of the percussion drilled borehole HFR106, which is drilled from an islet located ca 220 m southeast of the pier above SFR. The purpose of the location and orientation of the borehole is to investigate the possible occurrence of gently dipping, water-bearing structures in the area. HFR106 has a length of 190.4 m and oriented 269.4 deg/-60.9 deg. The mapping is based on the borehole image (BIPS), investigation of drill cuttings and generalized, as well as more detailed geophysical logs. The dominating rock type, which occupies 68% of HFR106, is fine- to medium-grained, pinkish grey metagranite-granodiorite (rock code 101057) mapped as foliated with a medium to strong intensity. Pegmatite to pegmatitic granite (rock code 101061) occupies 29% of the borehole. Subordinate rock types are felsic to intermediate meta volcanic rock (rock code 103076) and fine- to medium-grained granite (rock code 111058). Rock occurrences (rock types < 1 m in length) occupy about 16% of the mapped interval, of which half is veins, dykes and unspecified occurrences of pegmatite and pegmatitic granite. Only 5.5% of HFR106 is inferred to be altered, mainly oxidation in two intervals with an increased fracture frequency. A total number of 845 fractures are registered in HFR106. Of these are 64 interpreted as open with a certain aperture, 230 open with a possible aperture, and 551 sealed. This result in the following fracture frequencies: 1.6 open fractures/m and 3.0 sealed fractures/m. Three fracture sets of open and sealed fractures with the orientations 290 deg/70 deg, 150 deg/85 deg and 200 deg/85 deg can be distinguished in HFR106. The fracture frequency is generally higher in the second half of the borehole, and particularly in the interval 176-187.4 m.

  3. Site investigation SFR. Boremap mapping of percussion drilled borehole HFR106

    International Nuclear Information System (INIS)

    Winell, Sofia

    2010-06-01

    This report presents the result from the Boremap mapping of the percussion drilled borehole HFR106, which is drilled from an islet located ca 220 m southeast of the pier above SFR. The purpose of the location and orientation of the borehole is to investigate the possible occurrence of gently dipping, water-bearing structures in the area. HFR106 has a length of 190.4 m and oriented 269.4 deg/-60.9 deg. The mapping is based on the borehole image (BIPS), investigation of drill cuttings and generalized, as well as more detailed geophysical logs. The dominating rock type, which occupies 68% of HFR106, is fine- to medium-grained, pinkish grey metagranite-granodiorite (rock code 101057) mapped as foliated with a medium to strong intensity. Pegmatite to pegmatitic granite (rock code 101061) occupies 29% of the borehole. Subordinate rock types are felsic to intermediate meta volcanic rock (rock code 103076) and fine- to medium-grained granite (rock code 111058). Rock occurrences (rock types < 1 m in length) occupy about 16% of the mapped interval, of which half is veins, dykes and unspecified occurrences of pegmatite and pegmatitic granite. Only 5.5% of HFR106 is inferred to be altered, mainly oxidation in two intervals with an increased fracture frequency. A total number of 845 fractures are registered in HFR106. Of these are 64 interpreted as open with a certain aperture, 230 open with a possible aperture, and 551 sealed. This result in the following fracture frequencies: 1.6 open fractures/m and 3.0 sealed fractures/m. Three fracture sets of open and sealed fractures with the orientations 290 deg/70 deg, 150 deg/85 deg and 200 deg/85 deg can be distinguished in HFR106. The fracture frequency is generally higher in the second half of the borehole, and particularly in the interval 176-187.4 m

  4. Fundamental Research on Percussion Drilling: Improved rock mechanics analysis, advanced simulation technology, and full-scale laboratory investigations

    Energy Technology Data Exchange (ETDEWEB)

    Michael S. Bruno

    2005-12-31

    This report summarizes the research efforts on the DOE supported research project Percussion Drilling (DE-FC26-03NT41999), which is to significantly advance the fundamental understandings of the physical mechanisms involved in combined percussion and rotary drilling, and thereby facilitate more efficient and lower cost drilling and exploration of hard-rock reservoirs. The project has been divided into multiple tasks: literature reviews, analytical and numerical modeling, full scale laboratory testing and model validation, and final report delivery. Literature reviews document the history, pros and cons, and rock failure physics of percussion drilling in oil and gas industries. Based on the current understandings, a conceptual drilling model is proposed for modeling efforts. Both analytical and numerical approaches are deployed to investigate drilling processes such as drillbit penetration with compression, rotation and percussion, rock response with stress propagation, damage accumulation and failure, and debris transportation inside the annulus after disintegrated from rock. For rock mechanics modeling, a dynamic numerical tool has been developed to describe rock damage and failure, including rock crushing by compressive bit load, rock fracturing by both shearing and tensile forces, and rock weakening by repetitive compression-tension loading. Besides multiple failure criteria, the tool also includes a damping algorithm to dissipate oscillation energy and a fatigue/damage algorithm to update rock properties during each impact. From the model, Rate of Penetration (ROP) and rock failure history can be estimated. For cuttings transport in annulus, a 3D numerical particle flowing model has been developed with aid of analytical approaches. The tool can simulate cuttings movement at particle scale under laminar or turbulent fluid flow conditions and evaluate the efficiency of cutting removal. To calibrate the modeling efforts, a series of full-scale fluid hammer

  5. [Dispensing care at the dispensing counter in the conditions of a Czech pharmacy].

    Science.gov (United States)

    Macesková, B; Plevacová, H

    2005-03-01

    Evaluation of 108 cases when the pharmacist found a need to intervene into prescription verified the use of internationally employed system of classification of pharmaceutical interventions in the conditions of the Czech pharmacy of the basic type. The so-called dispensing care at the counter was provided by five participating pharmacists (out of seven working in the pharmacy) for a period of six months. The most frequently identified problems included: inappropriate use of medicaments--overdose, use at unsuitable time (28.7 %), a need to inform the patient (17.6 %), potentially ineffective therapy (12.9 %), drug interactions (7.4 %), suspected and potential undesirable effects of prescribed medicaments (7.4 %), and insufficient compliance (6.5 %). Solution of problems with medicaments was most frequently: a change in dosage (25.9 %), recommendation to consult the physician (24.1 %), and professional counselling on pharmacotherapy (23.1 %). The pharmacotherapeutic group identified as the one most frequently requiring a telephone consultation of the pharmacist and the physician was antibiotics, including antibacterial chemotherapeutic agents.

  6. Feasibility study of a biocompatible pneumatic dispensing system using mouse 3T3-J2 fibroblasts

    Science.gov (United States)

    Lee, Sangmin; Kim, Hojin; Kim, Joonwon

    2017-12-01

    This paper presents results for dispensing living cells using a pneumatic dispensing system to verify the feasibility of using this system to fabricate biomaterials. Living cells (i.e., mouse 3T3-J2 fibroblast) were dispensed with different dispensing pressures in order to evaluate the effect of dispensing process on cell viability and proliferation. Based on the results of a live-dead assay, more than 80% of cell viability has been confirmed which was reasonably similar to that in the control group. Furthermore, measurement of cell metabolic activity after dispensing confirmed that the dispensed cell proliferated at a rate comparable to that of the control group. These results demonstrate that the pneumatic dispensing system is a promising tool for fabrication of biomaterials.

  7. Rational dispensing and use of artemether-lumefantrine during ...

    African Journals Online (AJOL)

    This was a prospective-descriptive study involving visits to 200 private retail pharmacies (using a mystery shopper) and interviewing pregnant women at the municipal public hospitals in Dar es Salaam, ... There is therefore a need for continuing training of drug dispensers regarding antimalarial drugs use in pregnancy.

  8. Dispensing apparatus for use in a cued food delivery task.

    Science.gov (United States)

    Deweese, Menton M; Claiborne, Kimberly N; Ng, Jennifer; Dirba, Danika D; Stewart, Hannah L; Schembre, Susan M; Versace, Francesco

    2015-01-01

    Neurobiological models of obesity postulate that obese individuals have difficulty regulating food intake partly because they attribute excessive salience to stimuli signaling food availability. Typically, human studies that investigate the relationship between brain responses to food-related stimuli and obesity present food cues without subsequent delivery of food. However, in order to identify the brain correlates of cue reactivity, we must record brain responses to food-related cues signaling food availability. Therefore, we have developed a dispensing apparatus for use in a cued-food delivery task in which event-related potentials (ERPs) to food-related images predicting food delivery and images not predicting food delivery can be recorded. Here, we describe a method where:•The experimental apparatus dispenses an edible item (i.e., a chocolate candy) which may or may not be eaten, or a non-edible control item (e.g., a plastic bead).•Deposit boxes are available to store uneaten candies and the non-edible control items.•The dispensing mechanism is capable of recording the exact timestamp when each delivery event occurs (e.g., release from the dispenser, arrival in the receptacle, storage in the deposit box).

  9. Dispensing of vitamin products by retail pharmacies in South Africa ...

    African Journals Online (AJOL)

    Objective: The objective of this study was to analyse the dispensing patterns of vitamins (Anatomical Therapeutic Chemical (ATC) group A11) over a one-year period in a group of community pharmacies in South Africa. Design and setting: A retrospective drug utilisation study was conducted on community pharmacy ...

  10. Dispensing of drugs with and without a prescription from private ...

    African Journals Online (AJOL)

    There is little literature available on dispensing patterns and unsupervised sale of medicines from pharmacies in Tanzania. The present study assessed the patterns of drug acquisition from pharmacies by customers: whether by prescription, recommended by pharmacist, or requested by a customer without a prescription.

  11. Dispensing of vitamin products by retail pharmacies in South Africa ...

    African Journals Online (AJOL)

    Ilse Truter

    Survey) years.7 About 39% of US residents have used at least one multivitamin and ... The ATC Classification system is recommended by the. World Health ... Females in the 30 to 39-year age group were dispensed 21.95% of products ...

  12. Supplement to 1978 Catalogue of Wind and Percussion Solos and Ensembles. American School Band Directors' Association. Research Committee Reports for the Annual Convention (27th, Minneapolis, Minnesota, August 1-4, 1979).

    Science.gov (United States)

    Berndt, Arnold, Comp.

    This catalogue lists phonograph records which feature solo and ensemble music by wind and percussion instruments. It supplements the "1978 Catalogue of Wind and Percussion Solos and Ensembles" (ED 171 614). Instruments played on the records include oboe/English horn, flute, clarinet, bassoon, saxophone, trumpet/cornet, French horn, woodwind…

  13. 46 CFR 105.05-1 - Commercial fishing vessels dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Commercial fishing vessels dispensing petroleum products... MISCELLANEOUS VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Application § 105.05-1 Commercial fishing vessels dispensing petroleum products. (a) The provisions of this part, with the exception of...

  14. 46 CFR 105.45-1 - Loading or dispensing petroleum products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Loading or dispensing petroleum products. 105.45-1... VESSELS COMMERCIAL FISHING VESSELS DISPENSING PETROLEUM PRODUCTS Special Operating Requirements § 105.45-1 Loading or dispensing petroleum products. (a) A commercial fishing vessel must have aboard a letter of...

  15. Safety Analysis Report for Primary Capsule of Ir-192 Radiation Source

    International Nuclear Information System (INIS)

    Lee, J. C.; Bang, K. S.; Choi, W. S.; Seo, K. S.; Son, K. J.; Park, W. J.

    2008-12-01

    All of the source capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this project is to prove the safety of a primary capsule for Ir-192 radiation source which produced in the HANARO. The safety tests of primary capsules were carried out for the impact, percussion and heat conditions. And leakage tests were carried out before and after the each tests. The capsule showed slight scratches and their deformations were not found after each tests. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form radioactive materials

  16. Fabrication and Measurement of Low Work Function Cesiated Dispenser Photocathodes

    CERN Document Server

    Moody, Nathan A; Jensen, Kevin

    2005-01-01

    Photoinjector performance is a limiting factor in the continued development of high powered FELs and electron beam-based accelerators. Presently available photocathodes are plagued with limited efficiency and short lifetime in an RF-gun environment, due to contamination or evaporation of a photosensitive surface layer. An ideal photocathode should have high efficiency at long wavelengths, long lifetime in practical vacuum environments, and prompt emission. Cathodes with high efficiency typically have limited lifetime, and vice versa, and the needs of the photocathode are generally at odds with those of the drive laser. A potential solution is the low work function dispenser cathode, where lifetime issues are overcome by periodic in situ regeneration that restores the photosensitive surface layer, analogous to those used in the microwave power tube industry. This work reports on the fabrication techniques and performance of cesiated metal photocathodes and cesiated dispenser cathodes, with a focus on understan...

  17. All dispenser printed flexible 3D structured thermoelectric generators

    Science.gov (United States)

    Cao, Z.; Shi, J. J.; Torah, R. N.; Tudor, M. J.; Beeby, S. P.

    2015-12-01

    This work presents a vertically fabricated 3D thermoelectric generator (TEG) by dispenser printing on flexible polyimide substrate. This direct-write technology only involves printing of electrodes, thermoelectric active materials and structure material, which needs no masks to transfer the patterns onto the substrate. The dimension for single thermoelectric element is 2 mm × 2 mm × 0.5 mm while the distance between adjacent cubes is 1.2 mm. The polymer structure layer was used to support the electrodes which are printed to connect the top ends of the thermoelectric material and ensure the flexibility as well. The advantages and the limitations of the dispenser printed 3D TEGs will also be evaluated in this paper. The proposed method is potential to be a low-cost and scalable fabrication solution for TEGs.

  18. Impact of Robotic Dispensing Machines in German Pharmacies on ...

    African Journals Online (AJOL)

    As a result of using a robotic dispensing machine, personnel costs were reduced by an average of 4.6% during the first 12 months after start-up. Over-the-counter sales increased in the same period by an average of 6.8%. Despite average initial costs of 118,000 euros, total costs within the first 12 months fell in 50% of cases ...

  19. [Design and piloting of a structured service medication dispensing process].

    Science.gov (United States)

    Abaurre, Raquel; García-Delgado, Pilar; Maurandi, M Dolores; Arrebola, Cristóbal; Gastelurrutia, Miguel Ángel; Martínez-Martínez, Fernando

    2015-01-01

    The aim of this article is to design and pilot a protocol for the dispensing of medications service. Using the requirements proposed in the Ministry of Health Pharmaceutical Care Consensus, a literature search was made applying qualitative consensus techniques. An observational, cross-sectional study was conducted from March to June 2009. A total of 53 community pharmacies from 24 Spanish counties. Patients who requested one or more particular medications with or without medical prescription for their own use or for someone in their care. The personalised medication information (IPM), the problems associated with the medications (PRM), and the negative results associated with the medication (RNM), detected by the pharmacist each time medication was dispensed, as well as the perception of the pharmacist on the operability of the protocol were recorded. A total of 870 medications were dispensed, with 423 (48.6%) cases of lack of personalised medication information (IPM) being detected. PRM were detected in 10.11% of the dispensed medications, as well as 68 (7.81%) suspected RNM: safety (n = 35; 51.5%), effectiveness (n = 29; 42.6%) and necessity (n = 4; 5.8%). Almost two-thirds (65.21%) of the pharmacists said that the protocol is in operation. The designed protocol helped to detect deficiencies in the information to the patients about their medications, as well as the PRM and RNM, and is shown to be tool that is easy to use and apply. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  20. Dispensing with conscience: a legal and ethical assessment.

    Science.gov (United States)

    Wernow, Jerome R; Grant, Donald G

    2008-11-01

    For over 30 years, pharmacists have exercised the right to dispense medications in accordance with moral convictions based upon a Judeo-Christian ethic. What many of these practitioners see as an apparent shift away from this time-honored ethic has resulted in a challenge to this right. To review and analyze pharmacy practice standards, legal proceedings, and ethical principles behind conflicts of conscientious objection in dispensing drugs used for emergency contraception. We first searched the terms conscience and clause and Plan B and contraception and abortion using Google, Yahoo, and Microsoft Networks (2006-September 26, 2008). Second, we used Medscape to search professional pharmacy and other medical journals, restricting our terms to conscience, Plan B, contraceptives, and abortifacients. Finally, we employed Loislaw, an online legal archiving service, and did a global search on the phrase conscience clause to determine the status of the legal discussion. To date, conflicts in conscientious objection have arisen when a pharmacist believes that dispensing an oral contraceptive violates his or her moral understanding for the promotion of human life. Up to this time, cases in pharmacy have involved only practitioners from orthodox Christian faith communities, primarily devout Roman Catholics. A pharmacist's right to refuse the dispensing of abortifacients for birth control according to moral conscience over against a woman's right to reproductive birth control has created a conflict that has yet to be reconciled by licensing agents, professional standards, or courts of law. Our analysis of prominent conflicts suggests that the underlying worldviews between factions make compromise improbable. Risks and liabilities are dependent upon compliance with evolving state laws, specific disclosure of a pharmacist's moral objections, and professionalism in the handling of volatile situations. Objecting pharmacists and their employers should have clear policies and

  1. Direct-Dispense Polymeric Waveguides Platform for Optical Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Mohamad Hajj-Hassan

    2008-12-01

    Full Text Available We describe an automated robotic technique called direct-dispense to fabricate a polymeric platform that supports optical sensor arrays. Direct-dispense, which is a type of the emerging direct-write microfabrication techniques, uses fugitive organic inks in combination with cross-linkable polymers to create microfluidic channels and other microstructures. Specifically, we describe an application of direct-dispensing to develop optical biochemical sensors by fabricating planar ridge waveguides that support sol-gelderived xerogel-based thin films. The xerogel-based sensor materials act as host media to house luminophore biochemical recognition elements. As a prototype implementation, we demonstrate gaseous oxygen (O2 responsive optical sensors that operate on the basis of monitoring luminescence intensity signals. The optical sensor employs a Light Emitting Diode (LED excitation source and a standard silicon photodiode as the detector. The sensor operates over the full scale (0%-100% of O2 concentrations with a response time of less than 1 second. This work has implications for the development of miniaturized multisensor platforms that can be cost-effectively and reliably mass-produced.

  2. Community pharmacists’ attitudes and knowledge on dispensing drugs.

    Directory of Open Access Journals (Sweden)

    Baldon JP

    2006-03-01

    Full Text Available The present study aimed to assess knowledge and attitudes of the pharmacists on dispensing drugs to pregnant women. Methods: Cross-sectional study in 150 community pharmacies randomly selected in Curitiba (Brazil. A closed end questionnaire with 25 questions were used, including dispensing scenarios containing risk types A, B, D or X and questions on pharmacist interaction with pregnant women, physicians, and information sources availability. Results: Pharmacists performed appropriately in 53% of the encounters. Lower success were associated to prednison and captopril (24.8% in both, end cases producing more doubts were captopril (31.7% and simvastatin (30.7%. Most of the pharmacists state have advised drugs to pregnant women or contact to the physician to discuss about a prescription related with this issue. A Majority (64.4% did not feel able to understand FDA risk classification and did not have trustable information sources in pharmacy. Conclusions: Pharmacists dispensing drugs in Curitiba are not able to interpret information on the use of drugs in pregnant women, and they don have reliable information sources on the use of dugs in pregnancy. However, they advice and counsel drugs to pregnant women and discuss with physicians therapeutic strategies.

  3. Implementation and evaluation of an automated dispensing system.

    Science.gov (United States)

    Schwarz, H O; Brodowy, B A

    1995-04-15

    An institution's experience in replacing a traditional unit dose cassette-exchange system with an automated dispensing system is described. A 24-hour unit dose cassette-exchange system was replaced with an automated dispensing system (Pyxis's Medstation Rx) on a 36-bed cardiovascular surgery unit and an 8-bed cardiovascular intensive care unit. Significantly fewer missing doses were reported after Medstation Rx was implemented. No conclusions could be made about the impact of the system on the reporting of medication errors. The time savings for pharmacy associated with the filling, checking, and delivery of new medication orders equated to about 0.5 full-time equivalent (FTE). Medstation Rx also saved substantial nursing time for acquisition of controlled substances and for controlled-substance inventory taking at shift changes. A financial analysis showed that Medstation Rx could save the institution about $1 million over five years if all personnel time savings could be translated into FTE reductions. The automated system was given high marks by the nurses in a survey; 80% wanted to keep the system on their unit. Pilot implementation of an automated dispensing system improved the efficiency of drug distribution over that of the traditional unit dose cassette-exchange system.

  4. Limestone percussion tools from the late Early Pleistocene sites of Barranco León and Fuente Nueva 3 (Orce, Spain).

    Science.gov (United States)

    Barsky, Deborah; Vergès, Josep-María; Sala, Robert; Menéndez, Leticia; Toro-Moyano, Isidro

    2015-11-19

    In recent years, there is growing interest in the study of percussion scars and breakage patterns on hammerstones, cores and tools from Oldowan African and Eurasian lithic assemblages. Oldowan stone toolkits generally contain abundant small-sized flakes and their corresponding cores, and are characterized by their structural dichotomy of heavy- and light-duty tools. This paper explores the significance of the lesser known heavy-duty tool component, providing data from the late Lower Pleistocene sites of Barranco León and Fuente Nueva 3 (Orce, Spain), dated 1.4-1.2 Myr. Using quantitative and qualitative data from the large-sized limestone industries from these two major sites, we present a new methodology highlighting their morpho-technological features. In the light of the results, we discuss the shortfalls of extant classificatory methods for interpreting the role of percussive technology in early toolkits. This work is rooted in an experimental program designed to reproduce the wide range of percussion marks observed on the limestone artefacts from these two sites. A visual and descriptive reference is provided as an interpretative aid for future comparative research. Further experiments using a variety of materials and gestures are still needed before the elusive traces yield the secrets of the kinds of percussive activities carried out by hominins at these, and other, Oldowan sites. © 2015 The Author(s).

  5. Percussion and electrical stunning of Atlantic salmon (Salmo salar) after dewatering and subsequent effect on brain and heart activities nd subsequent

    NARCIS (Netherlands)

    Lambooij, E.; Grimsboe, E.; Vis, van de J.W.; Reimert, H.G.M.; Nortvedt, R.; Roth, B.

    2010-01-01

    The overall objective of the study was to evaluate a percussive and an electrical stunning method under laboratory conditions in Atlantic salmon. Evidence of unconsciousness and insensibility of the salmon was provided on the electroencephalogram (EEG) by the appearance of slow waves and spikes,

  6. Safety and effectiveness of the high-frequency chest wall oscillation vs intrapulmonary percussive ventilation in patients with severe COPD

    Directory of Open Access Journals (Sweden)

    Nicolini A

    2018-02-01

    Full Text Available Antonello Nicolini,1 Bruna Grecchi,2 Maura Ferrari-Bravo,3 Cornelius Barlascini4 1Respiratory Diseases Unit, Hospital of Sestri Levante, Sestri Levante, Italy; 2Rehabilitation Unit, ASL4 Chiavarese, Chiavari, Italy; 3Statistics Unit, ASL4 Chiavarese, Chiavari, Italy; 4Health Medicine Unit, Hospital of Sestri Levante, Sestri Levante, Italy Purpose: Chest physiotherapy is an important tool in the treatment of COPD. Intrapulmonary percussive ventilation (IPV and high-frequency chest wall oscillation (HFCWO are techniques designed to create a global percussion of the lung which removes secretions and probably clears the peripheral bronchial tree. We tested the hypothesis that adding IPV or HFCWO to the best pharmacological therapy (PT may provide additional clinical benefit over chest physiotherapy in patients with severe COPD. Methods: Sixty patients were randomized into three groups (20 patients in each group: IPV group (treated with PT and IPV, PT group with (treated with PT and HFCWO, and control group (treated with PT alone. Primary outcome measures included results on the dyspnea scale (modified Medical Research Council and Breathlessness, Cough, and Sputum scale (BCSS, as well as an evaluation of daily life activity (COPD Assessment Test [CAT]. Secondary outcome measures were pulmonary function testing, arterial blood gas analysis, and hematological examinations. Moreover, sputum cell counts were performed at the beginning and at the end of the study. Results: Patients in both the IPV group and the HFCWO group showed a significant improvement in the tests of dyspnea and daily life activity evaluations (modified Medical Research Council scale, BCSS, and CAT compared to the control group, as well as in pulmonary function tests (forced vital capacity, forced expiratory volume in 1 second, forced expiratory volume in 1 second/forced vital capacity%, total lung capacity, residual volume, diffusing lung capacity monoxide, maximal inspiratory

  7. IR and the Earth

    DEFF Research Database (Denmark)

    Corry, Olaf; Stevenson, Hayley

    2017-01-01

    , in the end, one finite interconnected space. Together these two starting points make for the basic conundrum of Inter- national Relations and the Earth: how does a divided world live on a single globe? This introduction first provides an overview of the recent rise of ‘the environment’ in international......, ‘what has the environment ever done for IR?’, before the plan for the rest of the book sketches the content and direction of the ensuing chapters that explore the problematique of International Relations and the Earth....

  8. A comparison of the therapeutic effectiveness of and preference for postural drainage and percussion, intrapulmonary percussive ventilation, and high-frequency chest wall compression in hospitalized cystic fibrosis patients.

    Science.gov (United States)

    Varekojis, Sarah M; Douce, F Herbert; Flucke, Robert L; Filbrun, David A; Tice, Jill S; McCoy, Karen S; Castile, Robert G

    2003-01-01

    Cystic fibrosis (CF) patients have abnormally viscid bronchial secretions that cause airway obstruction, inflammation, and infection that leads to lung damage. To enhance airway clearance and reduce airway obstruction, daily bronchopulmonary hygiene therapy is considered essential. Compare the effectiveness of and patient preferences regarding 3 airway clearance methods: postural drainage and percussion (PD&P), intrapulmonary percussive ventilation (IPV), and high-frequency chest wall compression (HFCWC). The participants were hospitalized CF patients >or= 12 years old. Effectiveness was evaluated by measuring the wet and dry weights of sputum obtained with each method. In random order, each patient received 2 consecutive days of each therapy, delivered 3 times daily for 30 minutes. Sputum was collected during and for 15 minutes after each treatment, weighed wet, then dried and weighed again. Participants rated their preferences using a Likert-type scale. Mean weights and preferences were compared using analysis of variance with repeated measures. Patient preferences were compared using Freidman's test. Twenty-four patients were studied. The mean +/- SD wet sputum weights were 5.53 +/- 5.69 g with PD&P, 6.84 +/- 5.41 g with IPV, and 4.77 +/- 3.29 g with HFCWC. The mean wet sputum weights differed significantly (p = 0.035). Wet sputum weights from IPV were significantly greater than those from HFCWC (p < 0.05). The mean dry sputum weights were not significantly different. With regard to overall preference and to the subcomponents of preference, none of the 3 methods was preferred over the others. HFCWC and IPV are at least as effective as vigorous, professionally administered PD&P for hospitalized CF patients, and the 3 modalities were equally acceptable to them. A hospitalized CF patient should try each therapy and choose his or her preferred modality.

  9. Milking liquid nano-droplets by an IR laser: a new modality for the visualization of electric field lines

    International Nuclear Information System (INIS)

    Vespini, Veronica; Coppola, Sara; Grilli, Simonetta; Paturzo, Melania; Ferraro, Pietro

    2013-01-01

    Liquid handling at micron- and nano-scale is of paramount importance in many fields of application such as biotechnology and biochemistry. In fact, the microfluidics technologies play an important role in lab-on-a-chip devices and, in particular, the dispensing of liquid droplets is a required functionality. Different approaches have been developed for manipulating, dispensing and controlling nano-droplets under a wide variety of configurations. Here we demonstrate that nano-droplets can be drawn from liquid drop or film reservoirs through a sort of milking effect achieved by the absorption of IR laser radiation into a pyroelectric crystal. The generation of the pyroelectric field induced by the IR laser is calculated numerically and a specific experiment has been designed to visualize the electric field stream lines that are responsible for the liquid milking effect. The experiments performed are expected to open a new route for the visualization, measure and characterization procedures in the case of electrohydrodynamic applications. (paper)

  10. Detailed IR aperture measurements

    CERN Document Server

    Bruce, Roderik; Garcia Morales, Hector; Giovannozzi, Massimo; Hermes, Pascal Dominik; Mirarchi, Daniele; Quaranta, Elena; Redaelli, Stefano; Rossi, Carlo; Skowronski, Piotr Krzysztof; Wretborn, Sven Joel; CERN. Geneva. ATS Department

    2016-01-01

    MD 1673 was carried out on October 5 2016, in order to investigate in more detail the available aperture in the LHC high-luminosity insertions at 6.5 TeV and β∗=40 cm. Previous aperture measurements in 2016 during commissioning had shown that the available aperture is at the edge of protection, and that the aperture bottleneck at β∗=40 cm in certain cases is found in the separation plane instead of in the crossing plane. Furthermore, the bottlenecks were consistently found in close to the upstream end of Q3 on the side of the incoming beam, and not in Q2 on the outgoing beam as expected from calculations. Therefore, this MD aimed at measuring IR1 and IR5 separately (at 6.5 TeV and β∗=40 cm, for 185 µrad half crossing angle), to further localize the bottlenecks longitudinally using newly installed BLMs, investigate the difference in aperture between Q2 and Q3, and to see if any aperture can be gained using special orbit bumps.

  11. Reflexões Sobre a Percussão Corporal Na Escola Municipal Aleixo Pereira Braga II

    Directory of Open Access Journals (Sweden)

    José Donizete Pedrosa Gomes

    2016-03-01

    Full Text Available ResumoPor que as ideias de disciplina, rigidez, distanciamento entre educador e educando são ainda tão exaltadas em nossa sociedade? Por que elas ainda são diretamente associadas à aprendizagem? Será que não existem outras formas da aprendizagem acontecer e que possam ser bem mais eficazes que esses modelos tradicionais de ensino? Essas foram as principais inquietações que nos nortearam a elaborar esse artigo. O grupo PET Conexão de Saberes - Música do Oprimido (UnB realizou no período de 16 de maio a 11 de julho de 2015 oficinas de percussão corporal na Escola Municipal Aleixo Pereira Braga II (Cidade Ocidental-GO. Convivemos com um grupo de crianças durante sábados pela manhã e percebemos que essa atividade musical gerou um ambiente de aprendizado dinâmico baseado em coletividade, ludicidade e afetividade. As crianças assimilaram as oficinas como brincadeiras e se sentiram à vontade para arriscar, experimentar e aprender sobre música. Dessa forma, essa experiência com crianças da Cidade Ocidental nos fez refletir sobre o papel da afetividade na Educação Infantil baseando-nos em artigos da área de Psicologia do Desenvolvimento e de Educação Socioemocional. Palavras-chave: Afetividade, educação infantil, ludicidade, percussão corporal, PET - Conexão de Saberes - Música do Oprimido.

  12. A frequency conversion mode for dispenser in the service station based on flow rate signal

    International Nuclear Information System (INIS)

    Liu, Y J; Tang, D; Huang, J B; Liu, J; Jia, P F

    2012-01-01

    Dispenser is an integrated fuel transport and measurement system at the service station. In this paper, we developed a frequency conversion mode for the dispenser, based on the flow rate signal which is obtained from the converter measuring flow capacity. After introducing the frequency conversion mode to dispenser, we obtained that pump rotates at a high speed when fuelled with high flow rate, and it rotates at a low speed when fuelled with low flow rate. This makes the fuel dispenser more energy-efficient and controllable. We also did some valve optimizations on the dispenser and developed a new control mode for preset refuelling based on the frequency conversion mode, Experimental and theoretical studies have shown that the new dispenser not only can meet the national standards, but also performs better than the ordinary one especially in preset refuelling.

  13. A Curriculum For Dispensing Optician A Case Study In Vietnam

    Directory of Open Access Journals (Sweden)

    Duong Dieu MD

    2015-08-01

    Full Text Available Until 2011 there had been no full-time training course for dispensing optician diploma in Vietnam. Most of the practicing opticians with no qualification and formal training have learnt their skills through apprentice. In response to the demand of the industry Nguyen Tat Thanh University Vietnam has teamed up with Bradford College United Kingdom to develop a curriculum for a of formal 2-year full-time training for dispensing optician. The curriculum is applied for 4 semesters and graduate gets called Intermediate Professional Diploma level included 4 semesters. In VN after high school students can obtain different many levels of study such as Intermediate Professional Diploma College Bachelor Master and PhD. The 1st semester is basis of Intermediate Professional Diploma level. The 2nd semester is the study of refractive error and primary care each for 4 weeks 100 hours in theory and primary eye care 4 weeks for theory 100 hours. Also in this semester the learners have practiced clinical rotation at the Ophthalmic Hospital Ophthalmic Service in General Hospital for 10 weeks. The 3rd semester is specialized of dispensing Optician included Lenses frame contact lenses and laboratory for optician. In the 4th semester the training concentrates in the management of the eyeglasses shop and practicing in making spectacles for customers are in the 4th semester. The 1st intake of the course was opened started in 2011 and had 30 students graduated in 2013. This paper describes the experience of developing the curriculum in the context of a developing country where the industry is still under regulated and less developed. The first program optician that privileged on primary eye care will be satisfied for community WHO 2020 1 optometrist for 50.000 people and 10 ophthalmologists for 1.000.000 people. Some characteristics of first course students have been noted. The result of this curriculum will be evaluated in the coming time.

  14. Impact of an automated dispensing system in outpatient pharmacies.

    Science.gov (United States)

    Humphries, Tammy L; Delate, Thomas; Helling, Dennis K; Richardson, Bruce

    2008-01-01

    To evaluate the impact of an automated dispensing system (ADS) on pharmacy staff work activities and job satisfaction. Cross-sectional, retrospective study. Kaiser Permanente Colorado (KPCO) outpatient pharmacies in September 2005. Pharmacists and technicians from 18 outpatient pharmacies. All KPCO outpatient pharmacists (n = 136) and technicians (n = 160) were surveyed regarding demographics and work activities and pharmacist job satisfaction. Work activities and job satisfaction were compared between pharmacies with and without ADS. Historical prescription purchase records from ADS pharmacies were assessed for pre-ADS to post-ADS changes in productivity. Self-reported pharmacy staff work activities and pharmacist job satisfaction. Pharmacists who responded to the demographic questionnaire (n = 74) were primarily women (60%), had a bachelor's degree in pharmacy (68%), and had been in practice for 10 years or more (53%). Responding technicians (n = 72) were predominantly women (80%) with no postsecondary degree (90%) and fewer than 10 years (68%) in practice. Pharmacists in ADS pharmacies who responded to the work activities questionnaire (n = 50) reported equivalent mean hours spent in patient care activities and filling medication orders compared with non-ADS pharmacists (n = 33; P > 0.05). Similarly, technicians in ADS pharmacies who responded to the work activities questionnaire (n = 64) reported equivalent mean hours spent in filling medication orders compared with non-ADS technicians (n = 38; P > 0.05). An equivalent proportion of ADS pharmacists reported satisfaction with their current job compared with non-ADS pharmacies (P > 0.05). Mean productivity did not increase appreciably after automation (P >0.05). By itself, installing an ADS does not appear to shift pharmacist work activities from dispensing to patient counseling or to increase job satisfaction. Shifting pharmacist work activities from dispensing to counseling and monitoring drug therapy outcomes

  15. Large area dispenser cathode applied to high current linac

    International Nuclear Information System (INIS)

    Yang Anmin; China Academy of Engineering Physics, Mianyang; Wu Dengxue; Liu Chenjun; Xia Liansheng; Wang Wendou; Zhang Kaizhi

    2005-01-01

    The paper introduced a dispenser cathode (411 M) which was 55 mm in diameter. A 200 kV long pulsed power generator with 2 μs flattop based on Marx-PEN and system with heat and voltage insulation were built. A 52 A space charge limited current was gained, when the temperature was 1165 degree C and the filament current was 18 A on the cathode and the voltage of the pulse was 75 kV at the cathode test stand. Experimental results show that the current values are consistent with the numerical simulation. The experiment reveals that the deflated gas will influence the cathode emission ability. (authors)

  16. Guide to Permitting Hydrogen Motor Fuel Dispensing Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, Carl [National Renewable Energy Lab. (NREL), Golden, CO (United States); Buttner, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burgess, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-03-28

    The purpose of this guide is to assist project developers, permitting officials, code enforcement officials, and other parties involved in developing permit applications and approving the implementation of hydrogen motor fuel dispensing facilities. The guide facilitates the identification of the elements to be addressed in the permitting of a project as it progresses through the approval process; the specific requirements associated with those elements; and the applicable (or potentially applicable) codes and standards by which to determine whether the specific requirements have been met. The guide attempts to identify all applicable codes and standards relevant to the permitting requirements.

  17. Dicer is dispensable for asymmetric RISC loading in mammals.

    Science.gov (United States)

    Betancur, Juan G; Tomari, Yukihide

    2012-01-01

    In flies, asymmetric loading of small RNA duplexes into Argonaute2-containing RNA-induced silencing complex (Ago2-RISC) requires Dicer-2/R2D2 heterodimer, which acts as a protein sensor for the thermodynamic stabilities of the ends of small RNA duplexes. However, the mechanism of small RNA asymmetry sensing in mammalian RISC assembly remains obscure. Here, we quantitatively examined RISC assembly and target silencing activity in the presence or absence of Dicer in mammals. Our data show that, unlike the well-characterized fly Ago2-RISC assembly pathway, mammalian Dicer is dispensable for asymmetric RISC loading in vivo and in vitro.

  18. The impact of automation on workload and dispensing errors in a hospital pharmacy.

    Science.gov (United States)

    James, K Lynette; Barlow, Dave; Bithell, Anne; Hiom, Sarah; Lord, Sue; Pollard, Mike; Roberts, Dave; Way, Cheryl; Whittlesea, Cate

    2013-04-01

    To determine the effect of installing an original-pack automated dispensing system (ADS) on dispensary workload and prevented dispensing incidents in a hospital pharmacy. Data on dispensary workload and prevented dispensing incidents, defined as dispensing errors detected and reported before medication had left the pharmacy, were collected over 6 weeks at a National Health Service hospital in Wales before and after the installation of an ADS. Workload was measured by non-participant observation using the event recording technique. Prevented dispensing incidents were self-reported by pharmacy staff on standardised forms. Median workloads (measured as items dispensed/person/hour) were compared using Mann-Whitney U tests and rate of prevented dispensing incidents were compared using Chi-square test. Spearman's rank correlation was used to examine the association between workload and prevented dispensing incidents. A P value of ≤0.05 was considered statistically significant. Median dispensary workload was significantly lower pre-automation (9.20 items/person/h) compared to post-automation (13.17 items/person/h, P automation (0.28%) than pre-automation (0.64%, P automation (ρ = 0.23, P automation improves dispensing efficiency and reduces the rate of prevented dispensing incidents. It is proposed that prevented dispensing incidents frequently occurred during periods of high workload due to involuntary automaticity. Prevented dispensing incidents occurring after a busy period were attributed to staff experiencing fatigue after-effects. © 2012 The Authors. IJPP © 2012 Royal Pharmaceutical Society.

  19. Regulations, Codes, and Standards (RCS) Template for California Hydrogen Dispensing Stations

    Energy Technology Data Exchange (ETDEWEB)

    Rivkin, C.; Blake, C.; Burgess, R.; Buttner, W.; Post, M.

    2012-11-01

    This report explains the Regulations, Codes, and Standards (RCS) requirements for hydrogen dispensing stations in the State of California. The reports shows the basic components of a hydrogen dispensing station in a simple schematic drawing; the permits and approvals that would typically be required for the construction and operation of a hydrogen dispensing station; and a basic permit that might be employed by an Authority Having Jurisdiction (AHJ).

  20. The 340B discount program: outpatient prescription dispensing patterns through contract pharmacies in 2012.

    Science.gov (United States)

    Clark, Bobby L; Hou, John; Chou, Chia-Hung; Huang, Elbert S; Conti, Rena

    2014-11-01

    Section 340B of the Public Health Service Act provides qualified organizations serving vulnerable populations with deep discounts for some outpatient medications. A 2010 regulatory change widely expanded the 340B program's reach, allowing these organizations to contract with retail pharmacies to dispense medications for eligible patients. Little is known about which medications are dispensed by contract pharmacies under the expanded program. We provide the first comparison of 340B prescriptions and all prescriptions dispensed in contract pharmacies. We used 2012 data from Walgreens, the national leader in 340B contract pharmacies. Medications used to treat chronic conditions such as diabetes, high cholesterol levels, asthma, and depression accounted for an overwhelming majority of all prescriptions dispensed at Walgreens as part of the 340B program. A higher percentage of antiretrovirals used to treat HIV/AIDS were dispensed through 340B prescriptions than through all prescriptions dispensed at Walgreens. The majority of 340B prescriptions dispensed at Walgreens originated at tuberculosis clinics, consolidated health centers, disproportionate-share hospitals, and Ryan White clinics. Our results suggest that 340B contract pharmacies dispense medications used to treat Americans' chronic disease burden and disproportionately dispense medications used by key vulnerable populations targeted by the program. Project HOPE—The People-to-People Health Foundation, Inc.

  1. The IRS-1 signaling system.

    Science.gov (United States)

    Myers, M G; Sun, X J; White, M F

    1994-07-01

    Insulin-receptor substrate 1 (IRS-1) is a principal substrate of the receptor tyrosine kinase for insulin and insulin-like growth factor 1, and a substrate for a tyrosine kinase activated by interleukin 4. IRS-1 undergoes multisite tyrosine phosphorylation and mediates downstream signals by 'docking' various proteins that contain Src homology 2 domains. IRS-1 appears to be a unique molecule; however, 4PS, a protein found mainly in hemopoietic cells, may represent another member of this family.

  2. PROJECT OF COAGULANT DISPENSER IN PULVERIZATION AERATOR WITH WIND DRIVE

    Directory of Open Access Journals (Sweden)

    Ewa Osuch

    2017-09-01

    Full Text Available Lakes are one of most important freshwater ecosystems, playing significant role in functioning of nature and human economy. Swarzędzkie Lake is good example of ecosystem, which in last half-century was exposed to the influence of strong anthropopressure. Direct inflow of sewage with large number of biogens coming to the lake with water of inflows caused distinct disturbance of its functioning. In autumn 2011 restoration begined on Swarzędzkie Lake for reduction of lake trophy and improvement of water quality. For achieving better and quicker effect, simultaneously combination of some methods was applied, among others method of oxygenation of over-bottom water with help of pulverization aerator and method of precise inactivation of phosphorus in water depths. Characterization and analysis of improved coagulant dispenser applying active substance only during work of pulverization aerator is the aim of this thesis. Principle of dispenser work, its structure and location in pulverization aerator were explained. It was stated, that introduction to water a factor initiating process of phosphorus inactivation causes significant reduction of mineral phosphorus in water and size of coagulant dose correlates with intensity of work of pulverization aerator with wind drive.

  3. Trends in radiopharmaceutical dispensing in a regional nuclear pharmacy

    International Nuclear Information System (INIS)

    Basmadjian, G.P.; Barker, K.; Johnston, J.; Stinchcomb, R.; Tarman, B.; Ice, R.D.

    1983-01-01

    In the last five years, the practice of nuclear medicine has undergone changes due to the advent of new imaging technologies and radiopharmaceuticals. These changes have had an impact upon the number and the type of radiopharmaceuticals dispensed in centralized nuclear pharmacies. With the advent of Computerized Axial Tomography Scanners (CAT), sophistication and wider acceptance of the Ultrasound imaging modality, nuclear medicine has had to change directions from utilizing radiopharmaceuticals for static organ imaging to functional type imaging and to resort to the use of new radiopharmaceuticals or to find other uses for the existing radiopharmaceuticals. The following trends in radiopharmaceutical dispensing in a regional nuclear pharmacy are evident: Brain procedures have declined by about 67% while nuclear cardiology studies have increased by over 2000%. Bone scans have increased by 72% while liver, renal and lung studies have shown no significant increase. These changes will continue as the practice of nuclear medicine concentrates more on functional studies and relegates other studies to newer imaging modalities

  4. The challenge of responsible dispensing: formal education versus professional practice

    Directory of Open Access Journals (Sweden)

    Nadine Judith Bezzegh

    2011-03-01

    Full Text Available The aim of the present study was to evaluate the education of Pharmaceutical Technicians for the activity of responsible dispensing. Based on a questionnaire with open and closed questions, the study sought to characterize the students, identify knowledge and attitudes regarding the Rational Use of Medications while addressing the limits and possibilities of professional and ethical dispensing in practice. In addition, a group dynamics session - focus group - was held as a forum for debate on responsible dispensing. The results showed that students tended to be mature, currently employed and were predominately women. Displaying adequate knowledge on Rational Use of Medications and of the corresponding legislation, the students reported difficulties exercising compatible practice. While the diagnosis pointed to the need for student preparation to enable ethical dispensing, the Focus Group highlighted the possibility for inclusion of a forum for reflection and debate on the ethics of dispensing as part of the Pharmaceutical Technician training.O presente trabalho tem como proposta avaliar a formação do Técnico em Farmácia para o exercício da dispensação responsável. A partir de um questionário com perguntas fechadas e abertas, o estudo envolveu a caracterização dos alunos, a identificação de conhecimentos e atitudes em relação ao Uso Racional dos Medicamentos com vistas ao delineamento dos limites e possibilidades do exercício profissional ético na dispensação. Além disso, foi realizada uma dinâmica grupal - grupo focal - com o objetivo de apreciar a constituição de um espaço de reflexão sobre a dispensação responsável. Os resultados evidenciaram um alunato de maior idade, inserido no mercado de trabalho e predominância de mulheres. Dispondo de conhecimento adequado sobre o Uso Racional dos Medicamentos e da legislação correspondente os alunos fazem referência às dificuldades no exercício de uma pr

  5. Pharmacists' role in opioid overdose: Kentucky pharmacists' willingness to participate in naloxone dispensing.

    Science.gov (United States)

    Freeman, Patricia R; Goodin, Amie; Troske, SuZanne; Strahl, Audra; Fallin, Amanda; Green, Traci C

    To assess pharmacists' willingness to initiate the dispensing of naloxone. As of 2015, Kentucky law permits certified pharmacists to dispense naloxone under a physician-approved protocol. Electronic survey (e-mail) gauging perception of pharmacists' role in opioid overdose and attitudes toward, and barriers to, naloxone dispensing. All Kentucky pharmacists with active licenses in 2015. Ordinal logistic regression was used to estimate the impact of pharmacist characteristics and attitudes on willingness to initiate naloxone dispensing, where the dependent variable was operationalized as a Likert-type question on a scale of 1 (not at all willing) to 6 (very willing). Of 4699 practicing Kentucky pharmacists, 1282 responded, of which 834 were community practitioners (response rate 27.3%). Pharmacists reported varying willingness to initiate naloxone dispensing, with 37.3% very willing (score 5 or 6) and 27.9% not willing (score 1 or 2). However, a majority of pharmacists reported willingness to dispense naloxone with a valid prescription (54.0%, score 5 or 6). Women pharmacists were 1.3 times more likely than men to be willing to initiate naloxone dispensing (95% confidence interval [CI] 1.0-1.6). Those who reported confidence in identifying individuals at risk for overdose were 1.2 times more likely to initiate dispensing, and those who reported confidence in ability to educate patients about overdose were 1.6 times more likely to express willingness to initiate naloxone dispensing (95% CIs, respectively, 1.0-1.3 and 1.4-1.8). Community pharmacists reported barriers to naloxone access at higher rates than pharmacists from other practice settings. Kentucky pharmacists are divided in their willingness to initiate naloxone dispensing; however, those who are confident in their ability to identify overdose risks are more willing. Increasing pharmacist confidence through appropriately designed education programs could facilitate pharmacist participation in naloxone

  6. Titration of High Frequency Percussive Ventilation by means of real-time monitoring of the viscoelastic respiratory system properties and endotracheal tubes pressure drop.

    OpenAIRE

    Lucangelo, Umberto

    2014-01-01

    2012/2013 The use of High Frequency Percussive Ventilation (HFPV) is still debated although this type of non-conventional ventilation has proven effective and safe in patients with acute respiratory failure. In the clinical practice, HFPV is not an intuitive ventilatory modality and the absence of real-time delivered volume monitoring produces disaffection among the physicians. Avoiding the "volutrauma" is the cornerstone of the "protective ventilation strategy", which assumes a cons...

  7. MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT. NATIONAL SANITATION FOUNDATION STANDARD NO. 18.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    THIS STANDARD COVERS THE SANITATION REQUIREMENTS FOR EQUIPMENT AND DEVICES WHICH DISPENSE FOOD OR BEVERAGE EITHER IN BULK OR PORTIONS. VENDING MACHINES OR BULK MILK DISPENSING EQUIPMENT ARE NOT COVERED IN THIS STANDARD. ITEMS COVERED INCLUDE THE BASIC PRINCIPLES OF DESIGN AND CONSTRUCTION, FOOD PROTECTION AND FREEDOM FROM HARBORAGES. MINIMUM…

  8. Poorly processed reusable surface disinfection tissue dispensers may be a source of infection.

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Jesse, Katrin; von Baum, Heike; Ostermeyer, Christiane

    2014-01-21

    Reusable surface disinfectant tissue dispensers are used in hospitals in many countries because they allow immediate access to pre-soaked tissues for targeted surface decontamination. On the other hand disinfectant solutions with some active ingredients may get contaminated and cause outbreaks. We determined the frequency of contaminated surface disinfectant solutions in reusable dispensers and the ability of isolates to multiply in different formulations. Reusable tissue dispensers with different surface disinfectants were randomly collected from healthcare facilities. Solutions were investigated for bacterial contamination. The efficacy of two surface disinfectants was determined in suspension tests against two isolated species directly from a contaminated solution or after 5 passages without selection pressure in triplicate. Freshly prepared use solutions were contaminated to determine survival of isolates. 66 dispensers containing disinfectant solutions with surface-active ingredients were collected in 15 healthcare facilities. 28 dispensers from nine healthcare facilities were contaminated with approximately 107 cells per mL of Achromobacter species 3 (9 hospitals), Achromobacter xylosoxidans or Serratia marcescens (1 hospital each). In none of the hospitals dispenser processing had been adequately performed. Isolates regained susceptibility to the disinfectants after five passages without selection pressure but were still able to multiply in different formulations from different manufacturers at room temperature within 7 days. Neglecting adequate processing of surface disinfectant dispensers has contributed to frequent and heavy contamination of use-solutions based on surface active ingredients. Tissue dispenser processing should be taken seriously in clinical practice.

  9. The fabrication of front electrodes of Si solar cell by dispensing printing

    International Nuclear Information System (INIS)

    Kim, Do-Hyung; Ryu, Sung-Soo; Shin, Dongwook; Shin, Jung-Han; Jeong, Jwa-Jin; Kim, Hyeong-Jun; Chang, Hyo Sik

    2012-01-01

    Highlights: ► We propose the process for the front silver electrode by employing dispensing method. ► The dispensing method is a non-contact printing process. ► The electrode by dispensing method has more uniform and narrower shape. ► The dispensing method helped to enhance the efficiency of solar cell by 0.8% absolute. - Abstract: The dispensing printing was applied to fabricate the front electrodes of silicon solar cell. In this method, a micro channel nozzle and normal Ag paste were employed. The aspect ratio and line width of electrodes could be controlled by the process variables such as the inner diameter of nozzle, dispensing speed, discharge pressure, and the gap between wafer and nozzle. For the nozzle with the inner diameter of 50 μm, the line width and aspect ratio of electrode were under 90 μm and more than ∼0.2, respectively. When comparing the efficiency of solar cell prepared by conventional screen printing and the dispensing printing, the latter exhibited 19.1%, which is 0.8% absolute higher than the former even with the same Ag paste. This is because the electrode by dispensing printing has uniform aspect ratio and narrow line width over the length of electrode.

  10. Estudo do gesto instrumental sob o prisma da Labanotation: o exemplo da Tapping Technique em Percussion Study I para violão solo de Arthur Kampela

    Directory of Open Access Journals (Sweden)

    Ledice Fernandes-Weiss

    2018-04-01

    Full Text Available Este estudo parte dos efeitos de percussão criados por Arthur Kampela em seu Percussion Study I visando compreender o movimento físico e o gesto instrumental do violonista como um fenômeno orgânico, intimamente relacionado com o gesto sonoro. Para tanto, utilizamos como ferramenta de análise a notação de movimentos coreográficos criada por Rudolf von Laban; este sistema é aplicado aos gestos requeridos para se realizarem cinco passagens da obra de Kampela onde os efeitos de percussão estão particularmente presentes. A partir da leitura dos cinetogramas criados, podemos observar uma predominância de movimentos em ricochete e outros efeitos percussivos que, além de promover um melhor relaxamento muscular, corroboram no impacto visual que a peça causa por sua gestualidade corporal. Observamos também que há uma notável exploração espacial do instrumento. Ao abordarmos o fazer musical de um ponto de vista coreográfico, entendemos este como um complexo que inclui o som produzido, os gestos e movimentos do performer, sua energia, seu corpo e o espaço que o circunda.

  11. Energy-efficiency potential of water dispensers; Energieeffizienzpotenzial bei Wasser-Dispensern

    Energy Technology Data Exchange (ETDEWEB)

    Grieder, T.

    2003-07-01

    This final report for the Swiss Federal Office of Energy presents the results of study carried out to assess the energy-savings potential available in the operation of water dispensers often found in banks, stores and offices. The energy consumption of three types of dispenser is examined and compared with American 'EnergyStar'-guidelines. The results of measurements made for day and night-time operation are presented and the energy-savings potentials offered by more appropriate operating scenarios are discussed. Recommendations are made to all parties involved, from the dispenser's manufacturer, water-supplier and service organisation through to the end user. For each category, a catalogue of measures that can be taken is presented, including modifications to the dispensers themselves and the installation of timers. Also, the energy consumption of dispensers is compared with that of using traditional mineral water bottles and a small conventional refrigerator.

  12. The tungsten powder study of the dispenser cathode

    International Nuclear Information System (INIS)

    Bao Jixiu; Wan Baofei

    2006-01-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes has been investigated for the different grain morphologies. It is shown that a fully cleaning step of the tungsten powder is so necessary that the tungsten powder will be reduction of oxide in hydrogen atmosphere above 700 deg. C. The porosity of the tungsten matrix distributes more even and the closed pore is fewer, the average granule size of the tungsten powder distributes more convergent. The porosity of the tungsten matrix and the evaporation of the activator are bigger and the pulse of the cathode is smaller when the granularity is bigger by the analysis of the electronic microscope and diode experiment

  13. The tungsten powder study of the dispenser cathode

    Science.gov (United States)

    Bao, Ji-xiu; Wan, Bao-fei

    2006-06-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes has been investigated for the different grain morphologies. It is shown that a fully cleaning step of the tungsten powder is so necessary that the tungsten powder will be reduction of oxide in hydrogen atmosphere above 700 °C. The porosity of the tungsten matrix distributes more even and the closed pore is fewer, the average granule size of the tungsten powder distributes more convergent. The porosity of the tungsten matrix and the evaporation of the activator are bigger and the pulse of the cathode is smaller when the granularity is bigger by the analysis of the electronic microscope and diode experiment.

  14. Influence of container structures and content solutions on dispensing time of ophthalmic solutions

    Directory of Open Access Journals (Sweden)

    Keiji Yoshikawa

    2010-05-01

    Full Text Available Keiji Yoshikawa1, Hiroshi Yamada21Yoshikawa Eye Clinic, Tokyo, Japan; 2Santen Pharmaceutical Co., Ltd., Osaka, JapanPurpose: To investigate the influence of container structures and content solutions on the time of dispensing from eye dropper bottles.Methods: Eye dropper bottle models, solution models (filtrate water/surfactant solution and a dispensing time measuring apparatus were prepared to measure the dispensing time.Results: With filtrate water and pressure thrust load of 0.3 MPa, the dispensing time significantly increased from 1.1 ± 0.5 seconds to 4.6 ± 1.1 seconds depending on the decrease of inner aperture diameters from 0.4 mm to 0.2 mm (P < 0.0001. When using the bottle models with inner aperture diameters of 0.4 mm or larger, the dispensing time became constant. The dispensing time using surfactant solution showed the same tendency as above. When pressure thrust load was large (0.07 MPa, the solution flew out continuously with inner aperture diameters of 0.4 mm or larger and the dispensing time could not be measured. The inner aperture diameter most strongly explained the variation of the dispensing time in both the content solutions in the multiple linear regression analysis (filtrate water: 46%, R2 = 0.462, surfactant solution: 56%, R2 = 0.563.Conclusions: Among content solutions and container structures, the dispensing time was mostly influenced by the diameter of the inner aperture of bottles.Keywords: dispensing time, model eye dropper bottle, model ophthalmic solution, nozzle internal space volume, nozzle inner aperture diameter

  15. Dispensing error rate after implementation of an automated pharmacy carousel system.

    Science.gov (United States)

    Oswald, Scott; Caldwell, Richard

    2007-07-01

    A study was conducted to determine filling and dispensing error rates before and after the implementation of an automated pharmacy carousel system (APCS). The study was conducted in a 613-bed acute and tertiary care university hospital. Before the implementation of the APCS, filling and dispensing rates were recorded during October through November 2004 and January 2005. Postimplementation data were collected during May through June 2006. Errors were recorded in three areas of pharmacy operations: first-dose or missing medication fill, automated dispensing cabinet fill, and interdepartmental request fill. A filling error was defined as an error caught by a pharmacist during the verification step. A dispensing error was defined as an error caught by a pharmacist observer after verification by the pharmacist. Before implementation of the APCS, 422 first-dose or missing medication orders were observed between October 2004 and January 2005. Independent data collected in December 2005, approximately six weeks after the introduction of the APCS, found that filling and error rates had increased. The filling rate for automated dispensing cabinets was associated with the largest decrease in errors. Filling and dispensing error rates had decreased by December 2005. In terms of interdepartmental request fill, no dispensing errors were noted in 123 clinic orders dispensed before the implementation of the APCS. One dispensing error out of 85 clinic orders was identified after implementation of the APCS. The implementation of an APCS at a university hospital decreased medication filling errors related to automated cabinets only and did not affect other filling and dispensing errors.

  16. Haemodynamics and oxygenation improvement induced by high frequency percussive ventilation in a patient with hypoxia following cardiac surgery: a case report

    Directory of Open Access Journals (Sweden)

    Persi Bruno

    2010-10-01

    Full Text Available Abstract Introduction High frequency percussive ventilation is a ventilatory technique that delivers small bursts of high flow respiratory gas into the lungs at high rates. It is classified as a pneumatically powered, pressure-regulated, time-cycled, high-frequency flow interrupter modality of ventilation. High frequency percussive ventilation improves the arterial partial pressure of oxygen with the same positive end expiratory pressure and fractional inspiratory oxygen level as conventional ventilation using a minor mean airway pressure in an open circuit. It reduces the barotraumatic events in a hypoxic patient who has low lung-compliance. To the best of our knowledge, there have been no papers published about this ventilation modality in patients with severe hypoxaemia after cardiac surgery. Case presentation A 75-year-old Caucasian man with an ejection fraction of 27 percent, developed a lung infection with severe hypoxaemia [partial pressure of oxygen/fractional inspiratory oxygen of 90] ten days after cardiac surgery. Conventional ventilation did not improve the gas exchange. He was treated with high frequency percussive ventilation for 12 hours with a low conventional respiratory rate (five per minute. His cardiac output and systemic and pulmonary pressures were monitored. Compared to conventional ventilation, high frequency percussive ventilation gives an improvement of the partial pressure of oxygen from 90 to 190 mmHg with the same fractional inspiratory oxygen and positive end expiratory pressure level. His right ventricular stroke work index was lowered from 19 to seven g-m/m2/beat; his pulmonary vascular resistance index from 267 to 190 dynes•seconds/cm5/m2; left ventricular stroke work index from 28 to 16 gm-m/m2/beat; and his pulmonary arterial wedge pressure was lowered from 32 to 24 mmHg with a lower mean airway pressure compared to conventional ventilation. His cardiac index (2.7 L/min/m2 and ejection fraction (27 percent

  17. Investigation of left and right lateral fluid percussion injury in C57BL6/J mice: In vivo functional consequences.

    Science.gov (United States)

    Schurman, Lesley D; Smith, Terry L; Morales, Anthony J; Lee, Nancy N; Reeves, Thomas M; Phillips, Linda L; Lichtman, Aron H

    2017-07-13

    Although rodent models of traumatic brain injury (TBI) reliably produce cognitive and motor disturbances, behavioral characterization resulting from left and right hemisphere injuries remains unexplored. Here we examined the functional consequences of targeting the left versus right parietal cortex in lateral fluid percussion injury, on Morris water maze (MWM) spatial memory tasks (fixed platform and reversal) and neurological motor deficits (neurological severity score and rotarod). In the MWM fixed platform task, right lateral injury produced a small delay in acquisition rate compared to left. However, injury to either hemisphere resulted in probe trial deficits. In the MWM reversal task, left-right performance deficits were not evident, though left lateral injury produced mild acquisition and probe trial deficits compared to sham controls. Additionally, left and right injury produced similar neurological motor task deficits, impaired righting times, and lesion volumes. Injury to either hemisphere also produced robust ipsilateral, and modest contralateral, morphological changes in reactive microglia and astrocytes. In conclusion, left and right lateral TBI impaired MWM performance, with mild fixed platform acquisition rate differences, despite similar motor deficits, histological damage, and glial cell reactivity. Thus, while both left and right lateral TBI produce cognitive deficits, laterality in mouse MWM learning and memory merits consideration in the investigation of TBI-induced cognitive consequences. Copyright © 2017. Published by Elsevier B.V.

  18. Implantation of Neuronal Stem Cells Enhances Object Recognition without Increasing Neurogenesis after Lateral Fluid Percussion Injury in Mice

    Directory of Open Access Journals (Sweden)

    Laura B. Ngwenya

    2018-01-01

    Full Text Available Cognitive deficits after traumatic brain injury (TBI are debilitating and contribute to the morbidity and loss of productivity of over 10 million people worldwide. Cell transplantation has been linked to enhanced cognitive function after experimental traumatic brain injury, yet the mechanism of recovery is poorly understood. Since the hippocampus is a critical structure for learning and memory, supports adult neurogenesis, and is particularly vulnerable after TBI, we hypothesized that stem cell transplantation after TBI enhances cognitive recovery by modulation of endogenous hippocampal neurogenesis. We performed lateral fluid percussion injury (LFPI in adult mice and transplanted embryonic stem cell-derived neural progenitor cells (NPC. Our data confirm an injury-induced cognitive deficit in novel object recognition, a hippocampal-dependent learning task, which is reversed one week after NPC transplantation. While LFPI alone promotes hippocampal neurogenesis, as revealed by doublecortin immunolabeling of immature neurons, subsequent NPC transplantation prevents increased neurogenesis and is not associated with morphological maturation of endogenous injury-induced immature neurons. Thus, NPC transplantation enhances cognitive recovery early after LFPI without a concomitant increase in neuron numbers or maturation.

  19. Use of a new novel humidification system with high frequency percussive ventilation in a patient with inhalation injury.

    Science.gov (United States)

    Jones, Samuel W; Short, Kathy A; Joseph, Mark; Sommer, Courtney; Cairns, Bruce A

    2010-01-01

    Historically, it has been difficult to provide adequate humidification delivery with the high frequency percussive ventilator (HFPV) used in many burn centers. It is possible burn centers have avoided using HFPV because of the risk of mucus plugging, dried secretions, and cast formation. Experiences with HFPV provided doubt that the HFPV ventilator circuit could supply adequate humidification to patients receiving this mode of ventilation. Independent gas-flow delivery through the ventilator circuit inherent in HFPV provided a challenge in maintaining adequate humidification delivery to the patient. This report describes a dramatic reduction in dried, inspissated secretions by using a novel new humidification device with HFPV. The new device called the Hydrate Omni (Hydrate, Inc., Midlothian, VA) uses a small ceramic disk to provide fine water particles delivered by a pump to the HFPV circuit. This new device may alleviate previous concerns related to the delivery of adequate humidification with the HFPV. This case report was approved by the University of North Carolina School of Medicine Institutional Review Board.

  20. CCD and IR array controllers

    Science.gov (United States)

    Leach, Robert W.; Low, Frank J.

    2000-08-01

    A family of controllers has bene developed that is powerful and flexible enough to operate a wide range of CCD and IR focal plane arrays in a variety of ground-based applications. These include fast readout of small CCD and IR arrays for adaptive optics applications, slow readout of large CCD and IR mosaics, and single CCD and IR array operation at low background/low noise regimes as well as high background/high speed regimes. The CCD and IR controllers have a common digital core based on user- programmable digital signal processors that are used to generate the array clocking and signal processing signals customized for each application. A fiber optic link passes image data and commands to VME or PCI interface boards resident in a host computer to the controller. CCD signal processing is done with a dual slope integrator operating at speeds of up to one Megapixel per second per channel. Signal processing of IR arrays is done either with a dual channel video processor or a four channel video processor that has built-in image memory and a coadder to 32-bit precision for operating high background arrays. Recent developments underway include the implementation of a fast fiber optic data link operating at a speed of 12.5 Megapixels per second for fast image transfer from the controller to the host computer, and supporting image acquisition software and device drivers for the PCI interface board for the Sun Solaris, Linux and Windows 2000 operating systems.

  1. Bacterial hand contamination and transfer after use of contaminated bulk-soap-refillable dispensers.

    Science.gov (United States)

    Zapka, Carrie A; Campbell, Esther J; Maxwell, Sheri L; Gerba, Charles P; Dolan, Michael J; Arbogast, James W; Macinga, David R

    2011-05-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log(10) CFU/ml of Serratia marcescens, an average of 5.28 log(10) CFU remained on each hand after washing, and 2.23 log(10) CFU was transferred to an agar surface. In an elementary-school-based field study, Gram-negative bacteria on the hands of students and staff increased by 1.42 log(10) CFU per hand (26-fold) after washing with soap from contaminated bulk-soap-refillable dispensers. In contrast, washing with soap from dispensers with sealed refills significantly reduced bacteria on hands by 0.30 log(10) CFU per hand (2-fold). Additionally, the mean number of Gram-negative bacteria transferred to surfaces after washing with soap from dispensers with sealed-soap refills (0.06 log(10) CFU) was significantly lower than the mean number after washing with contaminated bulk-soap-refillable dispensers (0.74 log(10) CFU; P soap (P soap from bulk-soap-refillable dispensers can increase the number of opportunistic pathogens on the hands and may play a role in the transmission of bacteria in public settings.

  2. Dispensing processes impact apparent biological activity as determined by computational and statistical analyses.

    Directory of Open Access Journals (Sweden)

    Sean Ekins

    Full Text Available Dispensing and dilution processes may profoundly influence estimates of biological activity of compounds. Published data show Ephrin type-B receptor 4 IC50 values obtained via tip-based serial dilution and dispensing versus acoustic dispensing with direct dilution differ by orders of magnitude with no correlation or ranking of datasets. We generated computational 3D pharmacophores based on data derived by both acoustic and tip-based transfer. The computed pharmacophores differ significantly depending upon dispensing and dilution methods. The acoustic dispensing-derived pharmacophore correctly identified active compounds in a subsequent test set where the tip-based method failed. Data from acoustic dispensing generates a pharmacophore containing two hydrophobic features, one hydrogen bond donor and one hydrogen bond acceptor. This is consistent with X-ray crystallography studies of ligand-protein interactions and automatically generated pharmacophores derived from this structural data. In contrast, the tip-based data suggest a pharmacophore with two hydrogen bond acceptors, one hydrogen bond donor and no hydrophobic features. This pharmacophore is inconsistent with the X-ray crystallographic studies and automatically generated pharmacophores. In short, traditional dispensing processes are another important source of error in high-throughput screening that impacts computational and statistical analyses. These findings have far-reaching implications in biological research.

  3. Evaluation of community pharmacies regarding dispensing practices of antibiotics in two districts of central Nepal.

    Directory of Open Access Journals (Sweden)

    Mukhtar Ansari

    Full Text Available To evaluate the status of community pharmacies, their staff, and practices toward dispensing antibiotics.Cross-sectional, prospective.Community pharmacies in two districts of central Nepal, from March 2016 to May 2016.A systematic random sampling approach was adopted to sample 161 community pharmacies. Data on the registration status of pharmacies, qualification or training of dispensing staff, and the practice of dispensing antibiotics were collected using a pre-tested questionnaire. Face to face interviews were carried out by a previously trained interviewer. Data were analyzed for descriptive and inferential statistics using IBM SPSS Statistics 21.Among 161 community pharmacies, 25% were not registered and most of them were located in rural areas. It was typical (66.5% to dispense antibiotics without prescription and most (91.4% of the staffs involved in dispensing were non-pharmacists. Furthermore, the study revealed common practices of replacing one brand of antibiotic with other brands (66%, dispensing incomplete courses of antibiotics (73%, and not giving any advice regarding antibiotic use (39% or completion of a full course of therapy (80%. There were significant (p < 0.001 relationships between the location of pharmacies (rural vs urban and the qualifications of the pharmacy staff.Dispensing antibiotics without prescription and by non-pharmacists are common in this region. The study also found several issues regarding the irrational use of antibiotics. Thus, there is an urgent need to address these issues and promote the informed use of antibiotics.

  4. High-Precision Dispensing of Nanoliter Biofluids on Glass Pedestal Arrays for Ultrasensitive Biomolecule Detection.

    Science.gov (United States)

    Chen, Xiaoxiao; Liu, Yang; Xu, QianFeng; Zhu, Jing; Poget, Sébastien F; Lyons, Alan M

    2016-05-04

    Precise dispensing of nanoliter droplets is necessary for the development of sensitive and accurate assays, especially when the availability of the source solution is limited. Conventional approaches are limited by imprecise positioning, large shear forces, surface tension effects, and high costs. To address the need for precise and economical dispensing of nanoliter volumes, we developed a new approach where the dispensed volume is dependent on the size and shape of defined surface features, thus freeing the dispensing process from pumps and fine-gauge needles requiring accurate positioning. The surface we fabricated, called a nanoliter droplet virtual well microplate (nVWP), achieves high-precision dispensing (better than ±0.5 nL or ±1.6% at 32 nL) of 20-40 nL droplets using a small source drop (3-10 μL) on isolated hydrophilic glass pedestals (500 μm on a side) bonded to arrays of polydimethylsiloxane conical posts. The sharp 90° edge of the glass pedestal pins the solid-liquid-vapor triple contact line (TCL), averting the wetting of the glass sidewalls while the fluid is prevented from receding from the edge. This edge creates a sufficiently large energy barrier such that microliter water droplets can be poised on the glass pedestals, exhibiting contact angles greater >150°. This approach relieves the stringent mechanical alignment tolerances required for conventional dispensing techniques, shifting the control of dispensed volume to the area circumscribed by the glass edge. The effects of glass surface chemistry and dispense velocity on droplet volume were studied using optical microscopy and high-speed video. Functionalization of the glass pedestal surface enabled the selective adsorption of specific peptides and proteins from synthetic and natural biomolecule mixtures, such as venom. We further demonstrate how the nVWP dispensing platform can be used for a variety of assays, including sensitive detection of proteins and peptides by fluorescence

  5. Hand sanitizer-dispensing door handles increase hand hygiene compliance: a pilot study.

    Science.gov (United States)

    Babiarz, Lukasz S; Savoie, Brent; McGuire, Mark; McConnell, Lauren; Nagy, Paul

    2014-04-01

    Improving rates of hand hygiene compliance (HHC) has been shown to reduce nosocomial disease. We compared the HHC for a traditional wall-mounted unit and a novel sanitizer-dispensing door handle device in a hospital inpatient ultrasound area. HHC increased 24.5%-77.1% (P sanitizer-dispensing door handle, whereas it remained unchanged for the other rooms. Technical improvements like a sanitizer-dispensing door handle can improve hospital HHC. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  6. Lyplal1 is dispensable for normal fat deposition in mice

    Directory of Open Access Journals (Sweden)

    Rachel A. Watson

    2017-12-01

    Full Text Available Genome-wide association studies (GWAS have detected association between variants in or near the Lysophospholipase-like 1 (LYPLAL1 locus and metabolic traits, including central obesity, fatty liver and waist-to-hip ratio. LYPLAL1 is also known to be upregulated in the adipose tissue of obese patients. However, the physiological role of LYPLAL1 is not understood. To investigate the function of Lyplal1 in vivo we investigated the phenotype of the Lyplal1tm1a(KOMPWtsi homozygous mouse. Body composition was unaltered in Lyplal1 knockout mice as assessed by dual-energy X-ray absorptiometry (DEXA scanning, both on normal chow and on a high-fat diet. Adipose tissue distribution between visceral and subcutaneous fat depots was unaltered, with no change in adipocyte cell size. The response to both insulin and glucose dosing was normal in Lyplal1tm1a(KOMPWtsi homozygous mice, with normal fasting blood glucose concentrations. RNAseq analysis of liver, muscle and adipose tissue confirmed that Lyplal1 expression was ablated with minimal additional changes in gene expression. These results suggest that Lyplal1 is dispensable for normal mouse metabolic physiology and that despite having been maintained through evolution Lyplal1 is not an essential gene, suggesting possible functional redundancy. Further studies will be required to clarify its physiological role.

  7. All-printed capacitors with continuous solution dispensing technology

    Science.gov (United States)

    Ge, Yang; Plötner, Matthias; Berndt, Andreas; Kumar, Amit; Voit, Brigitte; Pospiech, Doris; Fischer, Wolf-Joachim

    2017-09-01

    Printed electronics have been introduced into the commercial markets in recent years. Various printing technologies have emerged aiming to process printed electronic devices with low cost, environmental friendliness, and compatibility with large areas and flexible substrates. The aim of this study is to propose a continuous solution dispensing technology for processing all-printed thin-film capacitors on glass substrates using a leading-edge printing instrument. Among all printing technologies, this study provides concrete proof of the following outstanding advantages of this technology: high tolerance to inks, high throughput, low cost, and precise pattern transfers. Ag nanoparticle ink based on glycol ethers was used to print the electrodes. To obtain dielectric ink, a copolymer powder of poly(methyl methacrylate-co-benzoylphenyl methacrylate) containing crosslinkable side groups was dissolved in anisole. Various layouts were designed to support multiple electronic applications. Scanning electron microscopy and atomic force microscopy were used to investigate the all-printed capacitor layers formed using the proposed process. Additionally, the printed capacitors were electrically characterized under direct current and alternating current. The measured electrical properties of the printed capacitors were consistent with the theoretical results.

  8. Fascin 1 is dispensable for developmental and tumour angiogenesis

    Directory of Open Access Journals (Sweden)

    Yafeng Ma

    2013-09-01

    The actin bundling protein fascin 1 is not expressed in adult epithelial tissues, but during development it is transiently expressed in many different cell types, and later in adults it is expressed in a subset of immune cells, nervous tissues, endothelial cells, smooth muscle cells and pericytes. In contrast to the wealth of knowledge about the role of fascin 1 in cancer cell migration and invasion, little is known about the involvement of fascin 1 in angiogenesis. We speculated that as angiogenesis involves migration and invasion of tissues by endothelial cells, fascin 1 might have a role in both normal and tumour angiogenesis. Here, we provide evidence that loss of fascin 1 causes relatively minor reductions to angiogenesis during embryonic, postnatal and cancerous development by examining E12.5 hindbrains, postnatal retinas and B16F0 tumour cell allografts in fascin 1-null mice. We also find that in fascin 1 null tissues, endothelial cells display reduced filopodia formation during sprouting. We thus propose that fascin 1 expression promotes angiogenesis via filopodia formation, but is largely dispensable for both normal and tumour angiogenesis.

  9. A case of adverse drug reaction induced by dispensing error.

    Science.gov (United States)

    Gallelli, L; Staltari, O; Palleria, C; Di Mizio, G; De Sarro, G; Caroleo, B

    2012-11-01

    To report about a case of acute renal failure due to absence of communication between physician and patient. A 78 year old man with human immunodeficiency virus (HIV) accessed our hospital and was brought to our attention in August 2011 for severe renal failure. Clinical history revealed that he had been taking highly active antiretroviral therapy with lamivudine/abacavir and fosamprenavir since 2006. In April 2011 due to an augmentation in creatinine plasma levels, a reduction in lamivudine dosage to 100 mg/day and the prescription of abacavir 300 mg/day became necessary. Unfortunately, the patient took both lamivudine and abacavir therefore the association of the two medications (lamivudine/abacavir) lead to asthenia and acute renal failure within a few days. This case emphasizes the importance about how physicians must pay very careful attention during drug prescription, most particularly, as far as elderly patients are concerned. In fact, communication improvement between physicians and patients can prevent increase of adverse drug reactions related to drug dispensing, with consequential reduction of costs in the healthcare system. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  10. Lateral Fluid Percussion Injury Impairs Hippocampal Synaptic Soluble N-Ethylmaleimide Sensitive Factor Attachment Protein Receptor Complex Formation

    Directory of Open Access Journals (Sweden)

    Shaun W. Carlson

    2017-10-01

    Full Text Available Traumatic brain injury (TBI and the activation of secondary injury mechanisms have been linked to impaired cognitive function, which, as observed in TBI patients and animal models, can persist for months and years following the initial injury. Impairments in neurotransmission have been well documented in experimental models of TBI, but the mechanisms underlying this dysfunction are poorly understood. Formation of the soluble N-ethylmaleimide-sensitive factor attachment protein receptor (SNARE complex facilitates vesicular docking and neurotransmitter release in the synaptic cleft. Published studies highlight a direct link between reduced SNARE complex formation and impairments in neurotransmitter release. While alterations in the SNARE complex have been described following severe focal TBI, it is not known if deficits in SNARE complex formation manifest in a model with reduced severity. We hypothesized that lateral fluid percussion injury (lFPI reduces the abundance of SNARE proteins, impairs SNARE complex formation, and contributes to impaired neurobehavioral function. To this end, rats were subjected to lFPI or sham injury and tested for acute motor performance and cognitive function at 3 weeks post-injury. lFPI resulted in motor impairment between 1 and 5 days post-injury. Spatial acquisition and spatial memory, as assessed by the Morris water maze, were significantly impaired at 3 weeks after lFPI. To examine the effect of lFPI on synaptic SNARE complex formation in the injured hippocampus, a separate cohort of rats was generated and brains processed to evaluate hippocampal synaptosomal-enriched lysates at 1 week post-injury. lFPI resulted in a significant reduction in multiple monomeric SNARE proteins, including VAMP2, and α-synuclein, and SNARE complex abundance. The findings in this study are consistent with our previously published observations suggesting that impairments in hippocampal SNARE complex formation may contribute to

  11. In vivo 1H MR spectroscopic findings in traumatic contusion of ICR mouse brain induced by fluid percussion injury

    International Nuclear Information System (INIS)

    Choi, Chi-Bong; Kim, Hwi-Yool; Han, Duk-Young; Kang, Young-Woon; Han, Young-Min; Jeun, Sin-Soo; Choe, Bo-Young

    2005-01-01

    Purpose: The purpose of this study was to investigate the proton metabolic differences of the right parietal cortex with experimental brain contusions of ICR mouse induced by fluid percussion injury (FPI) compared to normal controls and to test the possibility that 1 H magnetic resonance spectroscopy (MRS) findings could provide neuropathologic criteria in the diagnosis and monitoring of traumatic brain contusions. Materials and methods: A homogeneous group of 20 ICR male mice was used for MRI and in vivo 1 H MRS. Using image-guided, water-suppressed in vivo 1 H MRS with a 4.7 T MRI/MRS system, we evaluated the MRS measurement of the relative proton metabolite ratio between experimental brain contusion of ICR mouse and healthy control subjects. Results: After trauma, NAA/Cr ratio, as a neuronal marker decreased significantly versus controls, indicating neuronal loss. The ratio of NAA/Cr in traumatic brain contusions was 0.90 ± 0.11, while that in normal control subjects was 1.13 ± 0.12 (P = 0.001). The Cho/Cr ratio had a tendency to rise in experimental brain contusions (P = 0.02). The Cho/Cr ratio was 0.91 ± 0.17, while that of the normal control subjects was 0.76 ± 0.15. However, no significant difference of Glx/Cr was established between the experimental traumatic brain injury models and the normal controls. Discussion and conclusions: The present 1 H MRS study shows significant proton metabolic changes of parietal cortex with experimental brain contusions of ICR mouse induced by FPI compared to normal controls. In vivo 1 H MRS may be a useful modality for the clinical evaluation of traumatic contusions and could aid in better understanding the neuropathologic process of traumatic contusions induced by FPI

  12. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    Energy Technology Data Exchange (ETDEWEB)

    Said, M. A.; Suhaimi, N. E. F. [Fakulti Sains dan Teknologi, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi Selangor (Malaysia); Ashhar, Z. N., E-mail: aminhpj@gmail.com [Institut Kanser Negara, No 4, Jalan P7, Presint 7, 62250 Putrajaya (Malaysia); Zainon, R. [Advanced Medical & Dental Institute, Universiti Sains Malaysia, Bertam, 13200, Kepala Batas, Pulau Pinang (Malaysia)

    2016-01-22

    In routine radiopharmaceutical Iodine-131 ({sup 131}I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle {sup 131}I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the {sup 131}I. The new fabricated of low cost {sup 131}I dispenser was tested and the dose received by personnel were evaluated. The body of lead material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of {sup 131} I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the {sup 131}I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of {sup 131}I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.

  13. Towards more reliable automated multi-dose dispensing: retrospective follow-up study on medication dose errors and product defects.

    Science.gov (United States)

    Palttala, Iida; Heinämäki, Jyrki; Honkanen, Outi; Suominen, Risto; Antikainen, Osmo; Hirvonen, Jouni; Yliruusi, Jouko

    2013-03-01

    To date, little is known on applicability of different types of pharmaceutical dosage forms in an automated high-speed multi-dose dispensing process. The purpose of the present study was to identify and further investigate various process-induced and/or product-related limitations associated with multi-dose dispensing process. The rates of product defects and dose dispensing errors in automated multi-dose dispensing were retrospectively investigated during a 6-months follow-up period. The study was based on the analysis of process data of totally nine automated high-speed multi-dose dispensing systems. Special attention was paid to the dependence of multi-dose dispensing errors/product defects and pharmaceutical tablet properties (such as shape, dimensions, weight, scored lines, coatings, etc.) to profile the most suitable forms of tablets for automated dose dispensing systems. The relationship between the risk of errors in dose dispensing and tablet characteristics were visualized by creating a principal component analysis (PCA) model for the outcome of dispensed tablets. The two most common process-induced failures identified in the multi-dose dispensing are predisposal of tablet defects and unexpected product transitions in the medication cassette (dose dispensing error). The tablet defects are product-dependent failures, while the tablet transitions are dependent on automated multi-dose dispensing systems used. The occurrence of tablet defects is approximately twice as common as tablet transitions. Optimal tablet preparation for the high-speed multi-dose dispensing would be a round-shaped, relatively small/middle-sized, film-coated tablet without any scored line. Commercial tablet products can be profiled and classified based on their suitability to a high-speed multi-dose dispensing process.

  14. Dispensing Equipment Testing with Mid-Level Ethanol/Gasoline Test Fluid: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, K.; Chapin, J. T.

    2010-11-01

    The National Renewable Energy Laboratory's (NREL) Nonpetroleum-Based Fuel Task addresses the hurdles to commercialization of biomass-derived fuels and fuel blends. One such hurdle is the unknown compatibility of new fuels with current infrastructure, such as the equipment used at service stations to dispense fuel into automobiles. The U.S. Department of Energy's (DOE) Vehicle Technology Program and the Biomass Program have engaged in a joint project to evaluate the potential for blending ethanol into gasoline at levels higher than nominal 10 volume percent. This project was established to help DOE and NREL better understand any potentially adverse impacts caused by a lack of knowledge about the compatibility of the dispensing equipment with ethanol blends higher than what the equipment was designed to dispense. This report provides data about the impact of introducing a gasoline with a higher volumetric ethanol content into service station dispensing equipment from a safety and a performance perspective.

  15. 21 CFR 866.2440 - Automated medium dispensing and stacking device.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2440... stacking device is a device intended for medical purposes to dispense a microbiological culture medium into...

  16. Hand sanitizer dispensers and associated hospital-acquired infections: friend or fomite?

    Science.gov (United States)

    Eiref, Simon D; Leitman, I Michael; Riley, William

    2012-06-01

    Waterless alcohol-based hand sanitizers are an increasingly popular method of hand hygiene and help prevent hospital-acquired infection (HAI). Whether hand sanitizer dispensers (HSDs) may themselves harbor pathogens or act as fomites has not been reported. All HSDs in the surgical intensive care unit of an urban teaching hospital were cultured at three sites: The dispenser lever, the rear underside, and the area surrounding the dispensing nozzle. All HSDs yielded one or more bacterial species, including commensal skin flora and enteric gram-negative bacilli. Colonization was greatest on the lever, where there is direct hand contact. Hand sanitizer dispensers can become contaminated with pathogens that cause HAI and thus are potential fomites.

  17. Impaired Insulin Signaling is Associated with Hepatic Mitochondrial Dysfunction in IR+/−-IRS-1+/− Double Heterozygous (IR-IRS1dh Mice

    Directory of Open Access Journals (Sweden)

    Andras Franko

    2017-05-01

    Full Text Available Mitochondria play a pivotal role in energy metabolism, but whether insulin signaling per se could regulate mitochondrial function has not been identified yet. To investigate whether mitochondrial function is regulated by insulin signaling, we analyzed muscle and liver of insulin receptor (IR+/−-insulin receptor substrate-1 (IRS-1+/− double heterozygous (IR-IRS1dh mice, a well described model for insulin resistance. IR-IRS1dh mice were studied at the age of 6 and 12 months and glucose metabolism was determined by glucose and insulin tolerance tests. Mitochondrial enzyme activities, oxygen consumption, and membrane potential were assessed using spectrophotometric, respirometric, and proton motive force analysis, respectively. IR-IRS1dh mice showed elevated serum insulin levels. Hepatic mitochondrial oxygen consumption was reduced in IR-IRS1dh animals at 12 months of age. Furthermore, 6-month-old IR-IRS1dh mice demonstrated enhanced mitochondrial respiration in skeletal muscle, but a tendency of impaired glucose tolerance. On the other hand, 12-month-old IR-IRS1dh mice showed improved glucose tolerance, but normal muscle mitochondrial function. Our data revealed that deficiency in IR/IRS-1 resulted in normal or even elevated skeletal muscle, but impaired hepatic mitochondrial function, suggesting a direct cross-talk between insulin signaling and mitochondria in the liver.

  18. The association between lifting an administrative restriction on antidepressant dispensing and treatment patterns in Iceland

    DEFF Research Database (Denmark)

    Thengilsdottir, G; Gardarsdottir, H; Almarsdóttir, Anna Birna

    2013-01-01

    On March 1st 2009, restrictions on the dispensing of selective serotonin reuptake inhibitors (SSRI) in Iceland were lifted. Incident rates and changes in early discontinuation and switching before and after the change were investigated.......On March 1st 2009, restrictions on the dispensing of selective serotonin reuptake inhibitors (SSRI) in Iceland were lifted. Incident rates and changes in early discontinuation and switching before and after the change were investigated....

  19. Multi-dose drug dispensing is a challenge across the primary-secondary care interface

    DEFF Research Database (Denmark)

    Reuther, Lene Orskov; Lysen, Charlotte; Faxholm, Mette

    2011-01-01

    Multi-dose drug dispensing (MDDD) signifies that the patient's medicine is packed in disposable bags corresponding to the dose that should be taken. The purpose of the present study was to investigate how a hospital MDDD instruction was followed.......Multi-dose drug dispensing (MDDD) signifies that the patient's medicine is packed in disposable bags corresponding to the dose that should be taken. The purpose of the present study was to investigate how a hospital MDDD instruction was followed....

  20. Rectangular section shield driving method applying percussion action. Construction of passage to disabled person elevator in Ichigaya Station; Pakasshon sayo wo riyoshita kukei danmen shirudo seko. Ichigaya Eki shinshoshayo erebeta renraku tsuro secchiko

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, T. [Teito Rapid Transit Authority, Tokyo (Japan); Endo, M. [Obayashi Corp., Osaka (Japan)

    1996-02-25

    Section forms of the shield driving method are mostly circular. This paper reports the work of a rectangular section shield driving method applying percussion action. Percussion type shield machines are outlined first showing figures and a specification table. Then the outline and method of the work now done is described. The work report is stated under the following 5 headings: Driving time by means of percussion, Assembling time of rectangular segments, Effect of movable head slide jacks, Propelling while driving, and Condition of surfaces driven. From the result now worked, the initial intention of driving a free section short passage at a low cost is considered achieved. Lastly, 6 items are discussed for further improvements. The advantages of the method are stated to be a simple mechanism, an availability to various soil conditions, a low production cost, and etc. 14 figs., 2 tabs.

  1. [Quality evaluation of rhubarb dispensing granules based on multi-component simultaneous quantitative analysis and bioassay].

    Science.gov (United States)

    Tan, Peng; Zhang, Hai-Zhu; Zhang, Ding-Kun; Wu, Shan-Na; Niu, Ming; Wang, Jia-Bo; Xiao, Xiao-He

    2017-07-01

    This study attempts to evaluate the quality of Chinese formula granules by combined use of multi-component simultaneous quantitative analysis and bioassay. The rhubarb dispensing granules were used as the model drug for demonstrative study. The ultra-high performance liquid chromatography (UPLC) method was adopted for simultaneously quantitative determination of the 10 anthraquinone derivatives (such as aloe emodin-8-O-β-D-glucoside) in rhubarb dispensing granules; purgative biopotency of different batches of rhubarb dispensing granules was determined based on compound diphenoxylate tablets-induced mouse constipation model; blood activating biopotency of different batches of rhubarb dispensing granules was determined based on in vitro rat antiplatelet aggregation model; SPSS 22.0 statistical software was used for correlation analysis between 10 anthraquinone derivatives and purgative biopotency, blood activating biopotency. The results of multi-components simultaneous quantitative analysisshowed that there was a great difference in chemical characterizationand certain differences inpurgative biopotency and blood activating biopotency among 10 batches of rhubarb dispensing granules. The correlation analysis showed that the intensity of purgative biopotency was significantly correlated with the content of conjugated anthraquinone glycosides (Panalysis and bioassay can achieve objective quantification and more comprehensive reflection on overall quality difference among different batches of rhubarb dispensing granules. Copyright© by the Chinese Pharmaceutical Association.

  2. Separation of prescribing and dispensing in Malaysia: the history and challenges.

    Science.gov (United States)

    Tiong, John Jeh Lung; Mai, Chun Wai; Gan, Pou Wee; Johnson, James; Mak, Vivienne Sook Li

    2016-08-01

    This article serves as an update to the work by Shafie et al. (2012) which previously reviewed the benefits of policies separating prescribing and dispensing in various countries to advocate its implementation in Malaysia. This article seeks to strengthen the argument by highlighting not only the weaknesses of the Malaysian health care system from the historical, professional and economic viewpoints but also the shortcomings of both medical and pharmacy professions in the absence of separation of dispensing. It also provides a detailed insight into the ongoing initiatives taken to consolidate the role of pharmacists in the health care system in the advent of separation of dispensing. Under the two tier system in Malaysia at present, the separation of prescribing and dispensing is implemented only in government hospitals. The absence of this separation in the private practices has led to possible profit-oriented medical and pharmacy practices which hinder safe and cost-effective delivery of health services. The call for separation of dispensing has gained traction over the years despite various hurdles ranging from the formidable resistance from the medical fraternity to the public's scepticism towards the new policy. With historical testament and present evidence pointing towards the merits of a system in which doctors prescribe and pharmacists dispense, the implementation of this health care model is justified. © 2016 The Authors. IJPP © 2016 Royal Pharmaceutical Society.

  3. Nanoliter Centrifugal Liquid Dispenser Coupled with Superhydrophobic Microwell Array Chips for High-Throughput Cell Assays

    Directory of Open Access Journals (Sweden)

    Yuyi Wang

    2018-06-01

    Full Text Available Microfluidic systems have been regarded as a potential platform for high-throughput screening technology in drug discovery due to their low sample consumption, high integration, and easy operation. The handling of small-volume liquid is an essential operation in microfluidic systems, especially in investigating large-scale combination conditions. Here, we develop a nanoliter centrifugal liquid dispenser (NanoCLD coupled with superhydrophobic microwell array chips for high-throughput cell-based assays in the nanoliter scale. The NanoCLD consists of a plastic stock block with an array of drilled through holes, a reagent microwell array chip (reagent chip, and an alignment bottom assembled together in a fixture. A simple centrifugation at 800 rpm can dispense ~160 nL reagents into microwells in 5 min. The dispensed reagents are then delivered to cells by sandwiching the reagent chip upside down with another microwell array chip (cell chip on which cells are cultured. A gradient of doxorubicin is then dispensed to the cell chip using the NanoCLD for validating the feasibility of performing drug tests on our microchip platform. This novel nanoliter-volume liquid dispensing method is simple, easy to operate, and especially suitable for repeatedly dispensing many different reagents simultaneously to microwells.

  4. Impact of alternative interventions on changes in generic dispensing rates.

    Science.gov (United States)

    O'Malley, A James; Frank, Richard G; Kaddis, Atheer; Rothenberg, Barbara M; McNeil, Barbara J

    2006-10-01

    To evaluate the effectiveness of four alternative interventions (member mailings, advertising campaigns, free generic drug samples to physicians, and physician financial incentives) used by a major health insurer to encourage its members to switch to generic drugs. Using claim-level data from Blue Cross Blue Shield of Michigan, we evaluated the success of four interventions implemented during 2000-2003 designed to increase the use of generic drugs among its members. Around 13 million claims involving seven important classes of drugs were used to assess the effectiveness of the interventions. For each intervention a control group was developed that most closely resembled the corresponding intervention group. Logistic regression models with interaction effects between the treatment group (intervention versus control) and the status of the intervention (active versus not active) were used to evaluate if the interventions had an effect on the generic dispensing rate (GDR). Because the mail order pharmacy was considered more aggressive at converting prescriptions to generics, separate generic purchasing models were fitted to retail and mail order claims. In secondary analyses separate models were also fitted to claims involving a new condition and claims refilled for preexisting conditions. The interventions did not appear to increase the market penetration of generic drugs for either retail or mail order claims, or for claims involving new or preexisting conditions. In addition, we found that the ratio of copayments for brand name to generic drugs had a large positive effect on the GDR. The interventions did not appear to directly influence the GDR. Financial incentives expressed to consumers through benefit designs have a large influence on their switching to generic drugs and on the less-costly mail-order mode of purchase.

  5. Justice Dispensation through the Alternative Dispute Resolution System in India

    Directory of Open Access Journals (Sweden)

    Krishna Agrawal

    2014-01-01

    Full Text Available The Law Commission of India in its 222nd report emphasized the need for Alternative Disputes Resolution (ADR for the dispensation of justice, because the courts are inaccessible owing to various factors, e.g., poverty, social and political backwardness, illiteracy, ignorance, procedural formalities and inordinate delay in judgments. During the ancient period the disputes were resolved in an informal manner by neutral third persons or people’s court in villages and it continued till the middle of the 20th century. Unfortunately, after the Independence of India in 1947, this system was dissuaded and the government permitted to continue the adversarial system of justice. In 1980, a committee was set up. It recommended Lok Adalats (People’s Courts. In 1987, the Legal Services Authorities Act was enacted. This Act obligates the states to provide free legal aid to poor persons. Besides this, the Act provides for the establishment of permanent Lok Adalats.This is one of the important modes of ADR. Lok Adalats have been established in all the districts of the country. They bring conciliatory settlement in complicated cases arising out of matrimonial, landlord-tenants, property, insurance and commercial disputes. There are four methods of ADR, viz., negotiation, mediation, conciliation and arbitration. Mediation and arbitration are widely preferred. They are alternatives to litigation. The Arbitration Act for the first time was enacted in 1889 and it was subsequently amended many times. On the objections raised by the Supreme Court of India and also on the adoption of UNCITRAL Model Law on International Commercial Arbitration, in 1996 Arbitration and Conciliation Act was enacted. This law is almost the same as is almost in all the countries.Further, the Government of India established International Centre for Alternative Disputes Resolution (CADR with the objectives of promotion, propagation, and popularizing the settlement of domestic and

  6. Back bombardment for dispenser and lanthanum hexaboride cathodes

    Directory of Open Access Journals (Sweden)

    Mahmoud Bakr

    2011-06-01

    Full Text Available The back bombardment (BB effect limits wide usage of thermionic rf guns. The BB effect induces not only ramping-up of a cathode’s temperature and beam current, but also degradation of cavity voltage and beam energy during a macropulse. This paper presents a comparison of the BB effect for the case of dispenser tungsten-base (DC and lanthanum hexaboride (LaB_{6} thermionic rf gun cathodes. For each, particle simulation codes are used to simulate the BB effect and electron beam dynamics in a thermionic rf gun cathode. A semiempirical equation is also used to investigate the stopping range and deposited heat power of BB electrons in the cathode material. A numerical simulation method is used to calculate the change of the cathode temperature and current density during a single macropulse. This is done by solving two differential equations for the rf gun cavity equivalent circuit and one-dimensional thermal diffusion equation. High electron emission and small beam size are required for generation of a high-brightness electron beam, and so in this work the emission properties of the cathode are taken into account. Simulations of the BB effect show that, for a pulse of 6  μs duration, the DC cathode experiences a large change in the temperature compared with LaB_{6}, and a change in current density 6 times higher. Validation of the simulation results is performed using experimental data for beam current beyond the gun exit. The experimental data is well reproduced using the simulation method.

  7. Impact of Pharmacists’ Religious and Personal Beliefs in Dispensing Contraceptives

    Directory of Open Access Journals (Sweden)

    Anna Krupa

    2016-10-01

    Full Text Available Background: Until recently, pharmacies were not permitted to dispense any emergency contraceptives to women to prevent pregnancy. No legal statutes existed under which pharmacists with religious, moral or ethical objections could refuse to fill a prescription for contraceptives, nor were there direct guidelines describing the pharmacist’s professional obligations. Objectives: The purpose of this study is to explore the frequency of cases in which pharmacists have refused, due to their personal beliefs, to provide counsel regarding contraceptives or have refused to refer to a patient to a different pharmacist or healthcare provider. This study will compare and contrast the differences between independent pharmacies and chain pharmacies (i.e. time spent, location, most common recommended contraception. Finally, this study will compare the results evident between male pharmacists and female pharmacists. Method: Quantitative method employed uses two interview questions directed to pharmacists: (1 “I am moving in with my fiancée/boyfriend next month and I have never used contraceptives. What are my options?” (2 “If I use a condom and it breaks, do I have any choices to prevent pregnancy after the fact?” The survey was conducted in two locations, the greater Philadelphia area and Hershey, PA. The survey was conducted through face-to-face interactions with pharmacists, either employed at independent pharmacy or at a chain pharmacy. Data collected from each pharmacist included number of approximate age/gender; minutes spent in each consultation with a patient; the kind of privacy provided during the consultation; and the referrals given, if any. Results: Fifty (50 pharmacists were interviewed. No pharmacist indicated that counseling would be denied, although one (1 pharmacist refused to counsel on Plan B and four (4 pharmacists referred the interviewer to a doctor immediately, indicating that all medications require a prescription. Two (2

  8. Prescribed 3-D Direct Writing of Suspended Micron/Sub-micron Scale Fiber Structures via a Robotic Dispensing System.

    Science.gov (United States)

    Yuan, Hanwen; Cambron, Scott D; Keynton, Robert S

    2015-06-12

    A 3-axis dispensing system is utilized to control the initiating and terminating fiber positions and trajectory via the dispensing software. The polymer fiber length and orientation is defined by the spatial positioning of the dispensing system 3-axis stages. The fiber diameter is defined by the prescribed dispense time of the dispensing system valve, the feed rate (the speed at which the stage traverses from an initiating to a terminating position), the gauge diameter of the dispensing tip, the viscosity and surface tension of the polymer solution, and the programmed drawing length. The stage feed rate affects the polymer solution's evaporation rate and capillary breakup of the filaments. The dispensing system consists of a pneumatic valve controller, a droplet-dispensing valve and a dispensing tip. Characterization of the direct write process to determine the optimum combination of factors leads to repeatedly acquiring the desired range of fiber diameters. The advantage of this robotic dispensing system is the ease of obtaining a precise range of micron/sub-micron fibers onto a desired, programmed location via automated process control. Here, the discussed self-assembled micron/sub-micron scale 3D structures have been employed to fabricate suspended structures to create micron/sub-micron fluidic devices and bioengineered scaffolds.

  9. Broadly tunable picosecond ir source

    International Nuclear Information System (INIS)

    Campillo, A.J.; Hyer, R.C.; Shapiro, S.L.

    1979-01-01

    A completely grating tuned (1.9 to 2.4 μm) picosecond traveling wave IR generator capable of controlled spectral bandwidth operation down to the Fourier Transform limit is reported. Subsequent down conversion in CdSe extends tuning to 10 to 20 μm

  10. Alkoholio ir tabako pasiūlos ir paklausos teisinio reguliavimo raida Lietuvos Respublikoje: problemos ir sprendimai

    OpenAIRE

    Mockevičius, Arminas

    2014-01-01

    Viešosios teisės magistro studijų programos studento Armino Mockevičiaus buvo parašytas magistro baigiamasis darbas „Alkoholio ir tabako pasiūlos ir paklausos teisinio reguliavimo raida Lietuvos Respublikoje: problemos ir sprendimai“. Šis darbas parašytas Vilniuje, 2014 metais, Mykolo Romerio universiteto Teisės fakulteto Konstitucinės ir administracinės teisės institute, vadovaujant dr. Gintautui Vilkeliui, apimtis 98 p. Darbo tikslas yra atskleisti alkoholio ir tabako pasiūlos ir paklau...

  11. A group music intervention using percussion instruments with familiar music to reduce anxiety and agitation of institutionalized older adults with dementia.

    Science.gov (United States)

    Sung, Huei-chuan; Lee, Wen-li; Li, Tzai-li; Watson, Roger

    2012-06-01

    This experimental study aimed to evaluate the effects of a group music intervention on anxiety and agitation of institutionalized older adults with dementia. A total of 60 participants were randomly assigned to an experimental or a control group. The experimental group received a 30-min music intervention using percussion instruments with familiar music in a group setting in mid afternoon twice weekly for 6 weeks, whereas the control group received usual care with no music intervention. The Rating of Anxiety in Dementia scale was used to assess anxiety, and Cohen-Mansfield Agitation Inventory was used to assess agitation at baseline, week 4 and week 6. Repeated measures analysis of covariance indicated that older adults who received a group music intervention had a significantly lower anxiety score than those in the control group while controlling for pre-test score and cognitive level (F = 8.98, p = 0.004). However, the reduction of agitation between two groups was not significantly different. Anxiety and agitation are common in older adults with dementia and have been reported by caregivers as challenging care problems. An innovative group music intervention using percussion instruments with familiar music as a cost-effective approach has the potential to reduce anxiety and improve psychological well-being of those with dementia. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Automated drug dispensing system reduces medication errors in an intensive care setting.

    Science.gov (United States)

    Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick

    2010-12-01

    We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; perror (20.4% and 13.5%; perror showed a significant impact of the automated dispensing system in reducing preparation errors (perrors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.

  13. Occurrence of heterotrophic and coliform bacteria in liquid hand soaps from bulk refillable dispensers in public facilities.

    Science.gov (United States)

    Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P

    2011-03-01

    The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.

  14. Oferta ir akceptas vartojimo sutartyse

    OpenAIRE

    Ežerskytė, Ramunė

    2011-01-01

    Sutarčiai sudaryti paprastai reikia, kad viena šalis pasiūlytų sudaryti sutartį (oferta), o kita šalis sutiktų su pasiūlymu (akceptas). Sutarčių įvairovėje išskiriamos vartojimo sutartys, kurios dėl silpnesnės šalies apsaugos principo įgyvendinimo pasižymi tam tikrais ypatumais. Vartojimo sutarčių sudarymas pateikiant ofertą ir akceptą yra šio magistro baigiamojo darbo objektas. Magistro baigiamąjį darbą sudaro trys dalys. Pirmojoje darbo dalyje analizuojama vartojimo sutarties sąvoka ir spec...

  15. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Science.gov (United States)

    Kampf, Günter; Degenhardt, Stina; Lackner, Sibylle; Ostermeyer, Christiane

    2014-01-01

    Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted Achromobacter species 3, when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%). Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation. Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential. PMID:24653973

  16. Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

    Directory of Open Access Journals (Sweden)

    Kampf, Günter

    2014-03-01

    Full Text Available [english] Background: It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted , when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. Methods: We evaluated the abilities of six manual and three automatic processes for processing contaminated dispensers to prevent recolonisation of a freshly-prepared disinfectant solution (Mikrobac forte 0.5%. Dispensers were left at room temperature for 28 days. Samples of the disinfectant solution were taken every 7 days and assessed quantitatively for bacterial contamination. Results: All automatic procedures prevented recolonisation of the disinfectant solution when a temperature of 60–70°C was ensured for at least 5 min, with or without the addition of chemical cleaning agents. Manual procedures prevented recontamination of the disinfectant solution when rinsing with hot water or a thorough cleaning step was performed before treating all surfaces with an alcohol-based disinfectant or an oxygen-releaser. Other cleaning and disinfection procedures, including the use of an alcohol-based disinfectant, did not prevent recolonisation.Conclusions: These results indicate that not all processes are effective for processing reusable dispensers for surface-disinfectant tissues, and that a high temperature during the cleaning step or use of a biofilm-active cleaning agent are essential.

  17. Climate Prediction Center IR 4km Dataset

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — CPC IR 4km dataset was created from all available individual geostationary satellite data which have been merged to form nearly seamless global (60N-60S) IR...

  18. Radioluminescence dating: the IR emission of feldspar

    International Nuclear Information System (INIS)

    Schilles, Thomas.; Habermann, Jan

    2000-01-01

    A new luminescence reader for radioluminescence (RL) measurements is presented. The system allows detection of RL emissions in the near infrared region (IR). Basic bleaching properties of the IR-RL emission of feldspars are investigated. Sunlight-bleaching experiments as a test for sensitivity changes are presented. IR-bleaching experiments were carried out to obtain information about the underlying physical processes of the IR-RL emission

  19. Isolated Gramicidin Peptides Probed by IR Spectroscopy

    NARCIS (Netherlands)

    Rijs, A. M.; Kabelac, M.; Abo-Riziq, A.; Hobza, P.; de Vries, M. S.

    2011-01-01

    We report double-resonant IR/UV ion-dip spectroscopy of neutral gramicidin peptides in the gas phase. The IR spectra of gramicidin A and C, recorded in both the 1000 cm(-1) to 1800 cm(-1) and the 2700 to 3750 cm(-1) region, allow structural analysis. By studying this broad IR range, various local

  20. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  1. [Dispensing prescriptions to persons affiliated with the Seguro Popular de Salud de México].

    Science.gov (United States)

    Garrido-Latorre, Francisco; Hernández-Llamas, Héctor; Gómez-Dantés, Octavio

    2008-01-01

    Measure and compare the percentage of prescriptions fully dispensed to persons with and without Popular Health Insurance (SPS in Spanish) who use ambulatory and general hospital services associated with the Mexico State Health Services (SESA in Spanish), and taking into account insurance status. SESA user satisfaction was also measured with respect to access to medication. Information for the study was taken from four surveys of SESA ambulatory and hospital units that included probabilistic samples with state representativity. Samples of ambulatory units were selected by stratification according to level of care and association to the SPS service network. The findings indicate that the percentage of prescriptions fully dispensed in SESA ambulatory units has improved, reaching approximately 90%, especially among those units offering services to persons affiliated with SPS. Nevertheless, these percentages continue to be lower than those of ambulatory units associated with social security institutions. Percentages of prescriptions fully dispensed have also improved in SESA hospital units, but continue to be relatively low. In nearly all states, as the percentage of prescriptions fully dispensed has increased, user satisfaction with access to medication has also improved. In 2006 more than 50% of the states had high levels of fully dispensed prescriptions among persons with SPS (> or =90%). The more significant problem exists among hospitals, since only 44% of users who received a prescription in SESA hospitals in 2006 had their prescriptions fully dispensed. This finding requires a review of SPS medication policies, which have favored highly prescribed low-cost medications at ambulatory services at the expense of higher cost and more therapeutically effective medications for hospital care, the latter having a greater impact on household budgets.

  2. Distance traveled and frequency of interstate opioid dispensing in opioid shoppers and nonshoppers.

    Science.gov (United States)

    Cepeda, M Soledad; Fife, Daniel; Yuan, Yingli; Mastrogiovanni, Greg

    2013-10-01

    Little is known about how far opioid shoppers travel or how often they cross state lines to fill their opioid prescriptions. This retrospective cohort study evaluated these measures for opioid shoppers and nonshoppers using a large U.S. prescription database. Patients with ≥3 opioid dispensings were followed for 18 months. A subject was considered a shopper when he or she filled overlapping opioid prescriptions written by >1 prescriber at ≥3 pharmacies. A heavy shopper had ≥5 shopping episodes. Outcomes assessed were distance traveled among pharmacies and number of states visited to fill opioid prescriptions. A total of 10,910,451 subjects were included; .7% developed any shopping behavior and their prescriptions accounted for 8.6% of all opioid dispensings. Shoppers and heavy shoppers were younger than the nonshoppers. Shoppers traveled a median of 83.8 miles, heavy shoppers 199.5 miles, and nonshoppers 0 miles. Almost 20% of shoppers or heavy shoppers, but only 4% of nonshoppers, visited >1 state. Shoppers traveled greater distances and more often crossed state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. Sharing of data among prescription-monitoring programs will likely strengthen those programs and may decrease shopping behavior. This study shows that opioid shoppers travel greater distances and more often cross state borders to fill opioid prescriptions than nonshoppers, and their dispensings accounted for a disproportionate number of opioid dispensings. The findings support the need for data sharing among prescription-monitoring programs to deter opioid shopping behavior. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.

  3. How can pharmacist remuneration systems in Europe contribute to generic medicine dispensing?

    Directory of Open Access Journals (Sweden)

    Dylst P

    2012-03-01

    Full Text Available Generic medicines can generate larger savings to health care budgets when their use is supported by incentives on both the supply-side and the demand-side. Pharmacists’ remuneration is one factor influencing the dispensing of generic medicines.Objective: The aim of this article is to provide an overview of different pharmacist remuneration systems for generic medicines in Europe, with a view to exploring how pharmacist remuneration systems can contribute to generic medicine dispensing.Methods: Data were obtained from a literature review, a Master thesis in Pharmaceutical Care at the Catholic University of Leuven and a mailing sent to all members of the Pharmaceutical Group of the European Union with a request for information about the local remuneration systems of community pharmacists and the possible existence of reports on discounting practices.Results: Pharmacists remuneration in most European countries consists of the combination of a fixed fee per item and a certain percentage of the acquisition cost or the delivery price of the medicines. This percentage component can be fixed, regressive or capped for very high-cost medicines and acts as a disincentive for dispensing generic medicines. Discounting for generic medicines is common practice in several European countries but information on this practice tends to be confidential. Nevertheless, data for Belgium, France, the Netherlands and United Kingdom indicated that discounting percentages varied from 10% to 70% of the wholesale selling price.Conclusion: Pharmacists can play an important role in the development of a generic medicines market. Pharmacists should not be financially penalized for dispensing generic medicines. Therefore, their remuneration should move towards a fee-for-performance remuneration instead of a price-dependent reimbursement which is currently used in many European countries. Such a fee-for-performance remuneration system provides a stimulus for generic medicines

  4. Effects of propranolol and clonidine on brain edema, blood-brain barrier permeability, and endothelial glycocalyx disruption after fluid percussion brain injury in the rat

    DEFF Research Database (Denmark)

    Genét, Gustav Folmer; Bentzer, Peter; Hansen, Morten Bagge

    2018-01-01

    clonidine would decrease brain edema, blood-brain barrier permeability, and glycocalyx disruption at 24 hours after trauma. METHODS: We subjected 53 adult male Sprague-Dawley rats to lateral fluid percussion brain injury and randomized infusion with propranolol (n = 16), propranolol + clonidine (n = 16......), vehicle (n = 16), or sham (n = 5) for 24 hours. Primary outcome was brain water content at 24 hours. Secondary outcomes were blood-brain barrier permeability and plasma levels of syndecan-1 (glycocalyx disruption), cell damage (histone-complexed DNA fragments), epinephrine, norepinephrine, and animal.......555). We found no effect of propranolol and propranolol/clonidine on blood-brain barrier permeability and animal motor scores. Unexpectedly, propranolol and propranolol/clonidine caused an increase in epinephrine and syndecan-1 levels. CONCLUSION: This study does not provide any support for unselective...

  5. IoT for Real-Time Measurement of High-Throughput Liquid Dispensing in Laboratory Environments.

    Science.gov (United States)

    Shumate, Justin; Baillargeon, Pierre; Spicer, Timothy P; Scampavia, Louis

    2018-04-01

    Critical to maintaining quality control in high-throughput screening is the need for constant monitoring of liquid-dispensing fidelity. Traditional methods involve operator intervention with gravimetric analysis to monitor the gross accuracy of full plate dispenses, visual verification of contents, or dedicated weigh stations on screening platforms that introduce potential bottlenecks and increase the plate-processing cycle time. We present a unique solution using open-source hardware, software, and 3D printing to automate dispenser accuracy determination by providing real-time dispense weight measurements via a network-connected precision balance. This system uses an Arduino microcontroller to connect a precision balance to a local network. By integrating the precision balance as an Internet of Things (IoT) device, it gains the ability to provide real-time gravimetric summaries of dispensing, generate timely alerts when problems are detected, and capture historical dispensing data for future analysis. All collected data can then be accessed via a web interface for reviewing alerts and dispensing information in real time or remotely for timely intervention of dispense errors. The development of this system also leveraged 3D printing to rapidly prototype sensor brackets, mounting solutions, and component enclosures.

  6. 40 CFR Table 1 to Subpart Cccccc... - Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly...

    Science.gov (United States)

    2010-07-01

    ... Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Applicability Criteria and Management Practices for Gasoline Dispensing Facilities With Monthly Throughput of 100,000 Gallons of Gasoline or More...

  7. Aspects of Chemical Composition and Somatic Cell count of Cow Milk Marketed at Dispensers

    Directory of Open Access Journals (Sweden)

    Mircea Valentin MUNTEAN

    2018-05-01

    Full Text Available Milk quality is influenced by many factors: lactation, fat, protein, lactose, number of somatic cells. In order to process raw milk and compare with criteria of quality and food safety the Regulation of European Parliament and the council no. 853/2004. Analysing the total number of somatic cells (SCC in the period July-August 2017 it is noted that in case of samples collected from first automatic milk dispenser exceed 2 times the maximum admissible values and the samples collected from second automatic milk dispenser are up to the maximum allowable values which show that milking hygiene and animal health are at the European standards required. Analysis of fat content for both cases indicates that it is within the standard values for cow's milk and fat variations for DM1 samples are very low at temperatures above 30 degrees Celsius which shows that high temperatures do not influence these parameters. The biological material study was represented analysed by 30 samples of milk from only two cow milk dispensers functional located in this period in Cluj-Napoca city. These samples were collected at the same time period during July-August months. The aim of present study is to determine whether milk marketed through dispensers under the high temperature conditions specific to this period is affected in terms of qualitative parameter analysis.

  8. The knowledge of emergency contraception and dispensing practices of Patent Medicine Vendors in South West Nigeria.

    Science.gov (United States)

    Fayemi, Mojisola M; Oduola, Olufemi L; Ogbuji, Queen C; Osinowo, Kehinde A; Oyewo, Adejoke E; Osiberu, Olabimpe M

    2010-09-01

    Patent Medicine Vendors (PMVs) can play a critical role in increasing access to emergency contraceptive pills (ECPs) in developing countries, but few studies have examined their knowledge and dispensing practices. Using cluster sampling, the authors selected and interviewed 97 PMVs (60.8 per cent female) in Oyo and Ogun States of Nigeria to assess their knowledge, dispensing practices, and referral for ECPs. About one-third (27.8 per cent) of respondents were not aware of ECPs, and only half knew that ECPs could prevent pregnancy. Forty per cent had ever dispensed ECPs. Reasons proffered by those who do not dispense ECPs included barriers from the State Ministry of Health, police, other regulatory agencies, and religious beliefs. Only 50.5 per cent have referral arrangements for clients. Strategies to increase access to ECPs through PMVs include training on counseling techniques and referral, effective government regulation, and community involvement. Where unsafe abortion is a major cause of maternal mortality, these strategies offer protection for many women in the future.

  9. Validation of a proxy for estrogen receptor status in breast cancer patients using dispensing data.

    Science.gov (United States)

    Srasuebkul, Preeyaporn; Dobbins, Timothy A; Pearson, Sallie-Anne

    2014-06-01

    To assess the performance of a proxy for estrogen receptor (ER) status in breast cancer patients using dispensing data. We derived our proxy using 167 patients. ER+ patients had evidence of at least one dispensing record for hormone therapy during the lookback period, irrespective of diagnosis date and ER- had no dispensing records for hormone therapy during the period. We validated the proxy against our gold standard, ER status from pathology reports or medical records. We assessed the proxy's performance using three lookback periods: 4.5 years, 2 years, 1 year. More than half of our cohort (62%) were >50 years, 54% had stage III/IV breast cancer at recruitment, (46%) were diagnosed with breast cancer in 2009 and 23% were diagnosed before 2006. Sensitivity and specificity were high for the 4.5 year lookback period (93%, 95% CI: 86-96%; and 95%: 83-99%), respectively) and remained high for the 2-year lookback period (91%: 84-95%; and 95%: 83-99%). Sensitivity decreased (83%: 75.2-89%) but specificity remained high (95%: 83-99%) using the 1-year lookback period and the period is long enough to allow sufficient time for hormone therapy to be dispensed. Our proxy accurately infers ER status in studies of breast cancer treatment based on secondary health data. The proxy is most robust with a minimum lookback period of 2 years. © 2012 Wiley Publishing Asia Pty Ltd.

  10. Efficacy of a Feed Dispenser for Horses in Decreasing Cribbing Behaviour

    Directory of Open Access Journals (Sweden)

    Silvia Mazzola

    2016-01-01

    Full Text Available Cribbing is an oral stereotypy, tends to develop in captive animals as a means to cope with stress, and may be indicative of reduced welfare. Highly energetic diets ingested in a short time are one of the most relevant risk factors for the development of cribbing. The aim of this study was to verify whether feeding cribbing horses through a dispenser that delivers small quantities of concentrate when activated by the animal decreases cribbing behaviour, modifies feeding behaviour, or induces frustration. Ten horses (mean age 14 y, balanced for sex, breed, and size (mean height 162 cm, were divided into two groups of 5 horses each: Cribbing and Control. Animals were trained to use the dispenser and videorecorded continuously for 15 consecutive days from 1 h prior to feeding to 2 h after feeding in order to measure their behaviours. The feed dispenser, Quaryka®, induced an increase in time necessary to finish the ration in both groups of horses (P<0.05. With Quaryka, cribbers showed a significant reduction of time spent cribbing (P<0.05. After removal of the feed dispenser (Post-Quaryka, cribbing behaviour significantly increased. The use of Quaryka may be particularly beneficial in horses fed high-energy diets and ingesting the food too quickly.

  11. Microbiological quality of drinking water from dispensers in roadside restaurants of Bangladesh.

    Science.gov (United States)

    Moniruzzaman, M; Akter, S; Islam, M A; Mia, Z

    2011-01-15

    The microbiological status of water from dispensers in different roadside restaurants of Dhaka city and Savar area was analyzed in this study. Seven samples from Dhaka and 8 samples of Savar were checked. The heterotrophic plate count was in a range of 1.0 x 10(3) CFU mL(-1) to 2.0 x 10(4) CFU mL(-1) (from new bottles), 1.0 x 10(3) to 1.5 x 10(4) CFU mL(-1) (after dispensation), and 1.5 x 10(3) CFU mL(-1) to 1.0 x l0(5) CFU mL(-1) (from serving glass). In several of the samples, the heterotrophic plate count was higher than the count in water from new bottle or after dispensation, suggesting added contamination from the serving glass. 80% of the samples were contaminated with total and fecal coliform bacteria, which render these waters unacceptable for human consumption. The samples were found to contain gram negative bacteria like E coli, Shigella sp., Klebsiella sp., Enterobacter sp., Pseudomonas sp., and Salmonella sp., which are potential pathogens and thus pose a serious threat to public health. This study elucidates the importance of monitoring the bottling companies and the restaurants and put them under strict regulations to prevent future outbreak of any water borne diseases caused by consumption of dispensed water.

  12. Smart DNA Fabrication Using Sound Waves: Applying Acoustic Dispensing Technologies to Synthetic Biology.

    Science.gov (United States)

    Kanigowska, Paulina; Shen, Yue; Zheng, Yijing; Rosser, Susan; Cai, Yizhi

    2016-02-01

    Acoustic droplet ejection (ADE) technology uses focused acoustic energy to transfer nanoliter-scale liquid droplets with high precision and accuracy. This noncontact, tipless, low-volume dispensing technology minimizes the possibility of cross-contamination and potentially reduces the costs of reagents and consumables. To date, acoustic dispensers have mainly been used in screening libraries of compounds. In this paper, we describe the first application of this powerful technology to the rapidly developing field of synthetic biology, for DNA synthesis and assembly at the nanoliter scale using a Labcyte Echo 550 acoustic dispenser. We were able to successfully downscale PCRs and the popular one-pot DNA assembly methods, Golden Gate and Gibson assemblies, from the microliter to the nanoliter scale with high assembly efficiency, which effectively cut the reagent cost by 20- to 100-fold. We envision that acoustic dispensing will become an instrumental technology in synthetic biology, in particular in the era of DNA foundries. © 2015 Society for Laboratory Automation and Screening.

  13. PMD: designing a portable medicine dispenser for persons suffering from Alzheimer’s disease

    NARCIS (Netherlands)

    de Beer, Roel C.J.M.; Keijers, R.; Shahid, S.; Al Mahmud, A.; Mubin, O.

    2010-01-01

    In this paper we present the user-centred design of a medicine dispenser for persons suffering from Alzheimer’s disease. The prototype was evaluated in two phases with two caregivers and two Alzheimer’s patients. Caregivers evaluated the device positively. The Alzheimer’s patients faced usability

  14. Correlation of emission capability and longevity of dispenser cathodes with characteristics of tungsten powders

    Science.gov (United States)

    Melnikova, Irina P.; Vorozheikin, Victor G.; Usanov, Dmitry A.

    2003-06-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes are investigated for three different grain morphologies. Best results of tungsten cathode life were found for isoaxis polyhedron morphology in combination with certain powder and matrix parameters.

  15. Correlation of emission capability and longevity of dispenser cathodes with characteristics of tungsten powders

    International Nuclear Information System (INIS)

    Melnikova, Irina P.; Vorozheikin, Victor G.; Usanov, Dmitry A.

    2003-01-01

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes are investigated for three different grain morphologies. Best results of tungsten cathode life were found for isoaxis polyhedron morphology in combination with certain powder and matrix parameters

  16. Correlation of emission capability and longevity of dispenser cathodes with characteristics of tungsten powders

    Energy Technology Data Exchange (ETDEWEB)

    Melnikova, Irina P.; Vorozheikin, Victor G.; Usanov, Dmitry A

    2003-06-15

    The intercorrelation of tungsten powder properties, such as grain size, distribution and morphology, and porous matrix parameters with electron emission capability and longevity of Ba dispenser cathodes are investigated for three different grain morphologies. Best results of tungsten cathode life were found for isoaxis polyhedron morphology in combination with certain powder and matrix parameters.

  17. Understanding vs. Competency: The Case of Accuracy Checking Dispensed Medicines in Pharmacy

    Science.gov (United States)

    James, K. Lynette; Davies, J. Graham; Kinchin, Ian; Patel, Jignesh P.; Whittlesea, Cate

    2010-01-01

    Ensuring the competence of healthcare professionals' is core to undergraduate and post-graduate education. Undergraduate pharmacy students and pre-registration graduates are required to demonstrate competence at dispensing and accuracy checking medicines. However, competence differs from understanding. This study determined the competence and…

  18. Exceptional circumstance drug dispensing: history and expenditures of the Brazilian Ministry of Health.

    Science.gov (United States)

    Carias, Claudia Mezleveckas; Vieira, Fabíola Sulpino; Giordano, Carlos V; Zucchi, Paola

    2011-04-01

    To describe the technical aspects of the Exceptional Circumstance Drug Dispensing Program of the Brazilian Ministry of Health, especially with respect to the cost of dispensed medication. Technical information was obtained from the ordinances that regulate the Program. Expenditure from 2000 to 2007 was obtained from the Sistema Único de Saúde's (Unified Healthcare System) Outpatient Information System. All drugs dispensed between 1993 and 2009 and the amount and cost of each procedure were evaluated, based on information from the high-complexity procedure authorization of each of the country's states. The Program changed with the increase in the number of pharmacological agents and presentations distributed by, and the number of diseases contemplated in the program. In 1993, the program distributed 15 pharmacological agents in 31 distinct presentations. This number increased to 109 agents in 243 presentations in 2009. Total Ministry of Health expenditure with medications was R$1,410,181,600.74 in 2007, almost twice the amount spent in 2000, R$684,975,404.43. Diseases whose expenditure increased in the period included chronic renal insufficiency, transplantation, and hepatitis C. The Exceptional Circumstance Drug Dispensing Program is in constant transformation, aimed at building instruments and strategies that can ensure and expand access to medication among the population. Alternatives should be sought to decrease the financial impact of the Program to a level that does not impact other sectors of the health care system, given the high cost associated with novel interventions.

  19. A systematic approach for the location of hand sanitizer dispensers in hospitals.

    Science.gov (United States)

    Cure, Laila; Van Enk, Richard; Tiong, Ewing

    2014-09-01

    Compliance with hand hygiene practices is directly affected by the accessibility and availability of cleaning agents. Nevertheless, the decision of where to locate these dispensers is often not explicitly or fully addressed in the literature. In this paper, we study the problem of selecting the locations to install alcohol-based hand sanitizer dispensers throughout a hospital unit as an indirect approach to maximize compliance with hand hygiene practices. We investigate the relevant criteria in selecting dispenser locations that promote hand hygiene compliance, propose metrics for the evaluation of various location configurations, and formulate a dispenser location optimization model that systematically incorporates such criteria. A complete methodology to collect data and obtain the model parameters is described. We illustrate the proposed approach using data from a general care unit at a collaborating hospital. A cost analysis was performed to study the trade-offs between usability and cost. The proposed methodology can help in evaluating the current location configuration, determining the need for change, and establishing the best possible configuration. It can be adapted to incorporate alternative metrics, tailored to different institutions and updated as needed with new internal policies or safety regulation.

  20. Surface contamination of counting tools after mock dispensing of cyclophosphamide in a simulated outpatient pharmacy.

    Science.gov (United States)

    Chaffee, Bruce W; Lander, Michael J; Christen, Catherine; Redic, Kimberly A

    2018-01-01

    Purpose The primary aim was to determine if dispensing of cyclophosphamide tablets resulted in accumulated residue on pharmacy counting tools during a simulated outpatient dispensing process. Secondary objectives included determining if cyclophosphamide contamination exceeded a defined threshold level of 1 ng/cm 2 and if a larger number of prescriptions dispensed resulted in increased contamination. Methods Mock prescriptions of 40 cyclophosphamide 50 mg tablets were counted on clean trays in three scenarios using a simulated outpatient pharmacy after assaying five cleaned trays as controls. The three scenarios consisted of five simulated dispensings of one, three, or six prescriptions dispensed per scenario. Wipe samples of trays and spatulas were collected and assayed for all trays, including the five clean trays used as controls. Contamination was defined as an assayed cyclophosphamide level at or above 0.001 ng/cm 2 and levels above 1 ng/cm 2 were considered sufficient to cause risk of human uptake. Mean contamination for each scenario was calculated and compared using one-way analysis of variance. P-values of contamination on trays used to count one, three, and six cyclophosphamide prescriptions was 0.51 ± 0.10 (p=0.0003), 1.02 ± 0.10 (p contamination. Increasing the number of prescriptions dispensed from 1 to 3, 1 to 6, and 3 to 6 counts increased contamination by 0.51 ± 0.15 (p = 0.0140), 1.31 + 0.15 (p contaminates pharmacy counting tools, and an increased number of prescriptions dispensed correlates with increased level of contamination. Counting out three or more prescriptions leads to trays having contamination that surpasses the threshold at which worker exposure may be increased. Pharmacies should consider devoting a separate tray to cyclophosphamide tablets, as cross-contamination could occur with other drugs and the efficacy of decontamination methods is unclear. Employee exposure could be minimized with the use

  1. Through-Silicon-Via Underfill Dispensing for 3D Die/Interposer Stacking

    Science.gov (United States)

    Le, Fuliang

    The next generation packaging keeps up with the increased demands of functionality by using the third dimension. 3D chip stacking with TSVs has been identified as one of the major technologies to achieve higher silicon density and shorter interconnection. In order to protect solder interconnections from hostile environments and redistribute thermal stress caused by CTE mismatch, underfill should be applied for the under-chip spaces. In this study, TSV underfill dispensing is introduced to address the underfill challenge for 3D chip stacks. The material properties are first measured and the general trend indicates viscosity and contact angle dropping significantly with an increase in temperature, and surface tension falling slightly as the temperature increases. Underfill should assure a complete encapsulation, avoiding excessive filling time that can result in substantial manufacturing delays. Typically, the inflows for TSV underfill can be free droplets or a constant flow rate. For a constant inflow, the underfill flow is driven by pressure difference and the filling time is governed by flow radius, gap clearance and the constant flow rate. For an inflow of free droplets, the underfill flow is driven by capillary action and the filling time is related to viscosity, flow radius, gap clearance, surface tension, contact angle and TSV size. In general, TSV underfill dispensing with a constant inflow has much shorter filling time than dispensing with an inflow of free droplets. TSV underfill dispensing on a 3D chip stack may induce the risk of an edge flood failure. In order to avoid an edge flood, fluid pressure around the sidewalls of a 3D chip stack cannot exceed limit equilibrium pressure. For TSV dispensing with free droplets, there is no risk of forming an edge flood. However, for a constant inflow, TSV dispensing should be carefully controlled to avoid excessive pressure. Besides, it is suggested that the TSVs in stacked chips be aligned in the vertical

  2. Innovations in IR projector arrays

    Science.gov (United States)

    Cole, Barry E.; Higashi, B.; Ridley, Jeff A.; Holmen, J.; Newstrom, K.; Zins, C.; Nguyen, K.; Weeres, Steven R.; Johnson, Burgess R.; Stockbridge, Robert G.; Murrer, Robert Lee; Olson, Eric M.; Bergin, Thomas P.; Kircher, James R.; Flynn, David S.

    2000-07-01

    In the past year, Honeywell has developed a 512 X 512 snapshot scene projector containing pixels with very high radiance efficiency. The array can operate in both snapshot and raster mode. The array pixels have near black body characteristics, high radiance outputs, broad band performance, and high speed. IR measurements and performance of these pixels will be described. In addition, a vacuum probe station that makes it possible to select the best die for packaging and delivery based on wafer level radiance screening, has been developed and is in operation. This system, as well as other improvements, will be described. Finally, a review of the status of the present projectors and plans for future arrays is included.

  3. Isolation of Raoultella planticola from refillable antimicrobial liquid soap dispensers in a dental setting.

    Science.gov (United States)

    Momeni, Stephanie S; Tomlin, Nancy; Ruby, John D

    2015-04-01

    Liquid antimicrobial soaps are commonly used in the dental health care setting for hand washing to minimize the potential spread of infectious agents to health care workers and patients. The purpose of the current study was to evaluate possible bacterial contamination of antimicrobial liquid soap dispensers located in 2 institutional comprehensive dental care clinics. Fourteen soap dispensers and 16 original stock containers were sampled. A 1-milliliter aliquot was diluted in 10 mL of phosphate buffer (Tween-80; Acros). Serial dilutions were plated in duplicate on neutralizing agar and incubated for 7 days. Molecular identification was performed using 500 base pair comparisons of 16S ribosomal ribonucleic acid sequencing. Taq polymerase chain reaction was performed with sequence-specific primers for Raoultella species. Bacterial growth was observed at 18 hours for 57% (8 of 14) of soap dispenser samples. Bacterial densities ranged from 4 × 10(2) to 6 × 10(9) colony-forming units per milliliter. Original commercial containers exhibited no growth. Isolates were identified as Raoultella (Klebsiella) planticola. This is the first study to the authors' knowledge indicating recovery of R. planticola from antimicrobial liquid soap dispensers. R. planticola is a recognized environmental opportunistic pathogen that potentially poses a health concern. These findings indicate compliance problems with infection prevention recommendations and support the US Centers for Disease Control and Prevention's recommendation that dispensers should not be topped off. High bacterial loads of R. planticola are inconsistent with infection control practices and are a concern because transmission and possible infection to the health care worker or the patient may occur. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  4. The expected and unexpected benefits of dispensing the exact number of pills.

    Science.gov (United States)

    Treibich, Carole; Lescher, Sabine; Sagaon-Teyssier, Luis; Ventelou, Bruno

    2017-01-01

    From November 2014 to November 2015, an experiment in French community pharmacies replaced traditional pre-packed boxes by per-unit dispensing of pills in the exact numbers prescribed, for 14 antibiotics. A cluster randomised control trial was carried out in 100 pharmacies. 75 pharmacies counted out the medication by units (experimental group), the other 25 providing the treatment in the existing pharmaceutical company boxes (control group). Data on patients under the two arms were compared to assess the environmental, economic and health effects of this change in drug dispensing. In particular, adherence was measured indirectly by comparing the number of pills left at the end of the prescribed treatment. Out of the 1185 patients included during 3 sessions of 4 consecutive weeks each, 907 patients experimented the personalized delivery and 278 were assigned to the control group, consistent with a 1/3 randomization-rate at the pharmacy level. 80% of eligible patients approved of the per-unit dispensing of their treatment. The initial packaging of the drugs did not match with the prescription in 60% of cases and per-unit dispensing reduced by 10% the number of pills supplied. 13.1% of patients declared that they threw away pills residuals instead of recycling-no differences between groups. Finally, per-unit dispensing appeared to improve adherence to antibiotic treatment (marginal effect 0.21, IC 95, 0.14-0.28). Supplying antibiotics per unit is not only beneficial in terms of a reduced number of pills to reimburse or for the environment (less pills wasted and non-recycled), but also has a positive and unexpected impact on adherence to treatment, and thus on both individual and public health.

  5. Population prevalence of high dose paracetamol in dispensed paracetamol/opioid prescription combinations: an observational study

    Science.gov (United States)

    2012-01-01

    Background Paracetamol (acetaminophen) is generally considered a safe medication, but is associated with hepatotoxicity at doses above doses of 4.0 g/day, and even below this daily dose in certain populations. Methods The Nova Scotia Prescription Monitoring Program (NSPMP) in the Canadian province of Nova Scotia is a legislated organization that collects dispensing information on all out-of-hospital prescription controlled drugs dispensed for all Nova Scotia residents. The NSPMP provided data to track all paracetamol/opioids redeemed by adults in Nova Scotia, from July 1, 2005 to June 30, 2010. Trends in the number of adults dispensed these prescriptions and the numbers of prescriptions and tablets dispensed over this period were determined. The numbers and proportions of adults who filled prescriptions exceeding 4.0 g/day and 3.25 g/day were determined for the one-year period July 1, 2009 to June 30, 2010. Data were stratified by sex and age (paracetamol/opioid prescription was lower in each successive one-year period. From July 2009 to June 2010, one in 12 adults (n = 59,197) filled prescriptions for over 13 million paracetamol/opioid tablets. Six percent (n = 3,786) filled prescriptions that exceeded 4.0 g/day and 18.6% (n = 11,008) exceeded 3.25 g/day of paracetamol at least once. These findings exclude non-prescription paracetamol and paracetamol–only prescribed medications. Conclusions A substantial number of individuals who redeem prescriptions for paracetamol/opioid combinations may be at risk of paracetamol-related hepatotoxicity. Healthcare professionals must be vigilant when prescribing and dispensing these medications in order to reduce the associated risks. PMID:22709372

  6. Twenty-year trends in benzodiazepine dispensing in the Australian population.

    Science.gov (United States)

    Islam, M M; Conigrave, K M; Day, C A; Nguyen, Y; Haber, P S

    2014-01-01

    Considerable concern has been expressed about overprescribing of benzodiazepines and related harms. Past analyses have relied on World Health Organization-defined daily doses (DDD) which are sometimes out of keeping with clinical usage. This study examines 20-year (1992-2011) trends of benzodiazepine dispensing in Australia using both DDD and Ashton equivalent dose. Data from the Drug Utilisation Sub-Committee and the Pharmaceutical Benefits Scheme (PBS) website were analysed. Trends in number of prescriptions, DDD/1000 people/day and DDD/prescription were examined over time, and between states/territories. In the 20-year period, 174 080 904 scripts were recorded, with temazepam the most dispensed benzodiazepine (35% of scripts), followed by diazepam (23%). Overall recorded utilisation fell from 27.7 DDD/1000 people/day in 1992 to 20.8 in 2011 (24.9% decrease). There were striking changes in use of individual benzodiazepines over time, with reductions in oxazepam and flunitrazepam and dramatic increases in alprazolam. Since 1998, there has been a steady increase, albeit modest, in per script DDD. The DDD/1000 people/day for items dispensed through PBS/Repatriaton-PBS was highest in Tasmania and lowest in Northern Territory. Despite a modest overall decline in the amount of benzodiazepine dispensed, the level of use is still likely to reflect relative over-prescribing given the paucity of accepted indications for long-term use. Since 1998, there was a polynomial increase in quantity dispensed per script. The WHO-defined DDD for clonazepam seems inappropriate and could impede monitoring of its abuse. Other problems include lack of national data for medications not subsidised on PBS/Repatriation PBS. A broad policy approach is required, not one which targets only one particular benzodiazepine. © 2013 The Authors; Internal Medicine Journal © 2013 Royal Australasian College of Physicians.

  7. STATYBINIŲ MEDŽIAGŲ KONKURENCINGUMAS IR TENDENCIJOS

    OpenAIRE

    Kontrimas, Robertas

    2010-01-01

    Darbe analizuojamas statybinių medžiagų konkurencingumas, nustatyti statybinių medžiagų konkurencingumą įtakojantys veiksniai ir pateikti pasiūlymai rinkos gerinimui. Pasitvirtino hipotezė, kad statybinių medžiagų paklausą ir kainas įtakoja klientų poreikiai ir jų finansinės galimybės, tačiau pasaulinės krizės įtaka yra labai ženkli,. Atlikta darbuotojų ir pirkėjų apklausa padėjo nustatyti, kokios statybinės medžiagos dažniausiai yra perkamos, kaip klientai ir darbuotojai vertina įmonę ir jos...

  8. Hermann agreement updates IRS guidelines for incentives.

    Science.gov (United States)

    Broccolo, B M; Peregrine, M W

    1995-01-01

    The October 1994 agreement between the Internal Revenue Service (IRS) and Hermann Hospital of Houston, Texas, elucidates current IRS policy on physician recruitment incentives. The IRS distinguishes between the recruiting and the retention of physicians and perimts incentives beyond reasonable compensation in the former but not the latter circumstance. This new agreement, while not legally precedential, nevertheless provides guidance for healthcare organizations seeking safe harbor protection.

  9. OH/IR stars in the Galaxy

    International Nuclear Information System (INIS)

    Baud, B.

    1978-01-01

    Radio astronomical observations leading to the discovery of 71 OH/IR sources are described in this thesis. These OH/IR sources are characterized by their double peaked OH emission profile at a wavelength of 18 cm and by their strong IR infrared emission. An analysis of the distribution and radial velocities of a number of previously known and new OH/IR sources was performed. The parameter ΔV (the velocity separation between two emission peaks of the 18 cm line profile) was found to be a good criterion for a population classification with respect to stellar age

  10. Atmospheric Entry Experiments at IRS

    Science.gov (United States)

    Auweter-Kurtz, M.; Endlich, P.; Herdrich, G.; Kurtz, H.; Laux, T.; Löhle, S.; Nazina, N.; Pidan, S.

    2002-01-01

    Entering the atmosphere of celestial bodies, spacecrafts encounter gases at velocities of several km/s, thereby being subjected to great heat loads. The thermal protection systems and the environment (plasma) have to be investigated by means of computational and ground facility based simulations. For more than a decade, plasma wind tunnels at IRS have been used for the investigation of TPS materials. Nevertheless, ground tests and computer simulations cannot re- place space flights completely. Particularly, entry mission phases encounter challenging problems, such as hypersonic aerothermodynamics. Concerning the TPS, radiation-cooled materials used for reuseable spacecrafts and ablator tech- nologies are of importance. Besides the mentioned technologies, there is the goal to manage guidance navigation, con- trol, landing technology and inflatable technologies such as ballutes that aim to keep vehicles in the atmosphere without landing. The requirement to save mass and energy for planned interplanetary missions such as Mars Society Balloon Mission, Mars Sample Return Mission, Mars Express or Venus Sample Return mission led to the need for manoeuvres like aerocapture, aero-breaking and hyperbolic entries. All three are characterized by very high kinetic vehicle energies to be dissipated by the manoeuvre. In this field flight data are rare. The importance of these manoeuvres and the need to increase the knowledge of required TPS designs and behavior during such mission phases point out the need of flight experiments. As result of the experience within the plasma diagnostic tool development and the plasma wind tunnel data base, flight experiments like the PYrometric RE-entry EXperiment PYREX were developed, fully qualified and successfully flown. Flight experiments such as the entry spectrometer RESPECT and PYREX on HOPE-X are in the conceptual phase. To increase knowledge in the scope of atmospheric manoeuvres and entries, data bases have to be created combining both

  11. Teaching IR to Medical Students: A Call to Action.

    Science.gov (United States)

    Lee, Aoife M; Lee, Michael J

    2018-02-01

    Interventional radiology (IR) has grown rapidly over the last 20 years and is now an essential component of modern medicine. Despite IR's increasing penetration and reputation in healthcare systems, IR is poorly taught, if taught at all, in most medical schools. Medical students are the referrers of tomorrow and potential IR recruits and deserve to be taught IR by expert IRs. The lack of formal IR teaching curricula in many medical schools needs to be addressed urgently for the continued development and dissemination of, particularly acute, IR services throughout Europe. We call on IRs to take up the baton to teach IR to the next generation of doctors.

  12. Reformulation of controlled-release oxycodone and pharmacy dispensing patterns near the US-Canada border.

    Science.gov (United States)

    Gomes, Tara; Paterson, J Michael; Juurlink, David N; Dhalla, Irfan A; Mamdani, Muhammad M

    2012-01-01

    In August 2010, a tamper-resistant formulation of controlled-release oxycodone (OxyContin-OP) was introduced in the United States but not in Canada. Our objective was to determine whether introduction of OxyContin-OP in the United States influenced prescription volumes for the original controlled-release oxycodone formulation (OxyContin) at Canadian pharmacies near the international border. We conducted a population-based, serial, cross-sectional study of prescriptions dispensed from pharmacies in the 3 cities with the highest volume of US-Canada border crossings in Ontario: Niagara Falls, Windsor and Sarnia. We analyzed data on all outpatient prescriptions for OxyContin dispensed by Canadian pharmacies near each border crossing between 2010 Apr. 1 and 2012 Feb. 29. We calculated and compared monthly prescription rates, adjusted per 1000 population and stratified by tablet strength. The number of tablets dispensed near 4 border crossings in the 3 Canadian cities remained stable over the study period. However, the rate of dispensing at pharmacies near the Detroit-Windsor Tunnel increased roughly 4-fold between August 2010 and February 2011, from 505 to 1969 tablets per 1000 population. By April 2011, following warnings to prescribers and pharmacies regarding drug-seeking behaviour, the dispensing rate declined to 1683 tablets per 1000 population in this area. By November 2011, the rate had returned to levels observed in early 2010. Our analyses suggest that 242 075 excess OxyContin tablets were dispensed near the Detroit-Windsor Tunnel between August 2010 and October 2011. Prescribing of the original formulation of controlled-release oxycodone rose substantially near a major international border crossing following the introduction of a tamper-resistant formulation in the United States. It is possible that the restriction of this finding to the area surrounding the Detroit-Windsor Tunnel reflects specific characteristics of this border crossing, including its high

  13. Identification of risks associated with the prescribing and dispensing of oral anticancer medicines in Ireland.

    LENUS (Irish Health Repository)

    Hammond, Lisa

    2012-09-09

    Background Oral anticancer medicines (OAM) facilitate transfer of cancer care into the community, where safeguards developed in hospitals that control their prescribing, dispensing and administration may not exist. Objective To determine if the systems of prescribing and dispensing OAM in Ireland facilitate clinical verification of the prescription, thereby ensuring treatment is tailored and appropriate for the patient. Setting Randomly selected community pharmacies in Ireland and all Irish hospitals with cancer services. Method A questionnaire was sent to a random selection of Irish community pharmacists. A different questionnaire was sent to all Irish hospitals treating cancer patients. One hundred OAM prescriptions were retrospectively reviewed, to assess the information presented and the potential barriers to a community pharmacist performing a clinical verification of the prescription. Main outcome measure Community pharmacist survey: problems experienced when dispensing OAM and risk factors identified with the current system. Hospital pharmacist survey: proportion of hospitals that clinically verify prescriptions for parenteral versus oral anticancer medicines and associated policies. OAM prescription review: proportion of OAM prescriptions that contained sufficient information for a community pharmacist to clinically verify the prescription and safely dispense the medication. Results Sixty-four percent of community pharmacist respondents felt they did not have enough information available to them to safely dispense these prescriptions, and 74 % felt that patients are at risk with the current Irish system of prescribing and dispensing OAM. Irish hospitals do not have systems to ensure that all OAM prescriptions are clinically verified by a pharmacist. Seventeen different agents were prescribed on the prescriptions reviewed. The information provided to the community pharmacist would have allowed them to clinically verify 7 % of the OAM prescriptions

  14. Premier's imaging IR limb sounder

    Science.gov (United States)

    Kraft, Stefan; Bézy, Jean-Loup; Meynart, Roland; Langen, Jörg; Carnicero Dominguez, Bernardo; Bensi, Paolo; Silvestrin, Pierluigi

    2017-11-01

    The Imaging IR Limb Sounder (IRLS) is one of the two instruments planned on board of the candidate Earth Explorer Core Mission PREMIER. PREMIER stands for PRocess Exploration through Measurements of Infrared and Millimetre-wave Emitted Radiation. PREMIER went recently through the process of a feasibility study (Phase A) within the Earth Observation Envelope Program. Emerging from recent advanced instrument technologies IRLS shall, next to a millimetre-wave limb sounder (called STEAMR), explore the benefits of three-dimensional limb sounding with embedded cloud imaging capability. Such 3D imaging technology is expected to open a new era of limb sounding that will allow detailed studies of the link between atmospheric composition and climate, since it will map simultaneously fields of temperature and many trace gases in the mid/upper troposphere and stratosphere across a large vertical and horizontal field of view and with high vertical and horizontal resolution. PREMIER shall fly in a tandem formation looking backwards to METOP's swath and thereby improve meteorological and environmental analyses.

  15. Atom condensation on an atomically smooth surface: Ir, Re, W, and Pd on Ir(111)

    International Nuclear Information System (INIS)

    Wang, S.C.; Ehrlich, G.

    1991-01-01

    The distribution of condensing metal atoms over the two types of sites present on an atomically smooth Ir(111) has been measured in a field ion microscope. For Ir, Re, W, and Pd from a thermal source, condensing on Ir(111) at ∼20 K, the atoms are randomly distributed, as expected if they condense at the first site struck

  16. Biochemical applications of FT-IR spectroscopy

    NARCIS (Netherlands)

    Pistorius, A.M.A.

    1996-01-01

    This thesis describes the use of (FT-)IR spectroscopy in general biochemical research. In chapter 3, IR spectroscopy is used in the quantitation of residual detergent after reconstitution of an integral membrane protein in a pre-defined lipid matrix. This chapter discusses the choice of the

  17. How to remedy Eurocentrism in IR?

    DEFF Research Database (Denmark)

    Bilgin, Pinar

    2016-01-01

    While IR's Eurocentric limits are usually acknowledged, what those limits mean for theorizing about the international is seldom clarified. In The Global Transformation, Buzan and Lawson offer a 'composite approach' that goes some way towards addressing IR's Eurocentrism, challenging existing myth...

  18. Quantitative gas analysis with FT-IR

    DEFF Research Database (Denmark)

    Bak, J.; Larsen, A.

    1995-01-01

    Calibration spectra of CO in the 2.38-5100 ppm concentration range (22 spectra) have been measured with a spectral resolution of 4 cm(-1), in the mid-IR (2186-2001 cm(-1)) region, with a Fourier transform infrared (FT-IR) instrument. The multivariate calibration method partial least-squares (PLS1...

  19. Benzene adsorption and oxidation on Ir(111)

    NARCIS (Netherlands)

    Weststrate, C.J.; Bakker, J.W.; Gluhoi, A.C.; Ludwig, W.; Nieuwenhuys, B.E.

    2007-01-01

    Adsorption, decompn. and oxidn. of benzene on Ir(1 1 1) was studied by high resoln. (synchrotron) XPS, temp. programmed desorption and LEED. Mol. adsorption of benzene on Ir(1 1 1) is obsd. between 170 K and 350 K. Above this temp. both desorption and decompn. of benzene take place. An ordered

  20. Smulkaus ir vidutinio verslo konkurencingumas Lietuvoje

    OpenAIRE

    Vijeikis, Juozas; Makštutis, Antanas

    2009-01-01

    Straipsnio mokslinė problema, naujumas ir aktualumas. Konkurencingumas kaip įmonių efektyvios veiklos reiškinys yra aktualus šalies verslo gyvenime vykdant darnios ekonominės plėtros politiką. Ši politika kaip problema smulkaus ir vidutinio verslo (SVV) plėtrai ir konkurencingumui didinti nėra sistemiškai ištirta ir aprašyta Lietuvos sąlygomis mokslinėje ir praktinėje literatūroje. Vienas svarbiausių veiksnių, siekiant spartaus ekonominio augimo, yra darnios verslininkystės plėtra Lietuvoje n...

  1. Analysis of costs to dispense prescriptions in independently owned, closed-door long-term care pharmacies.

    Science.gov (United States)

    Carroll, Norman V; Rupp, Michael T; Holdford, David A

    2014-03-01

    The need for accurate calculation of long-term care (LTC) pharmacies' costs to dispense (CTD) has become more important as payers have moved toward reimbursement models based on pharmacies' actual acquisition cost for drug products and the Centers for Medicare Medicaid Services (CMS) has implemented requirements that LTC pharmacies must dispense prescriptions for certain branded drugs in 14-day-or-less quantities. To (a) calculate the average cost that the typical independently owned, closed-door LTC pharmacy currently incurs to dispense and deliver a prescription to the resident of a client LTC facility and (b) estimate how CMS-mandated changes to a 14-day-or-less dispensing cycle would affect the typical LTC pharmacy's average CTD. The data requirements and measurement model were developed by academic researchers in consultation with an industry advisory committee of independent LTC pharmacy owners. A survey instrument was constructed to collect financial and operating data required to calculate the CTD. Surveys were distributed via 3 dissemination channels to approximately 1,000 independently owned, closed-door LTC pharmacies. The National Community Pharmacists Association mailed surveys to their LTC members; 3 major national wholesalers distributed surveys to their LTC customers through their newsletters; and 3 LTC group purchasing organizations distributed the surveys to their members through emails, newsletters, mailings, and/or regional meetings. Each pharmacy's CTD was calculated by dividing total LTC dispensing-related 
costs by the total number of prescriptions dispensed. Dispensing-related costs included costs incurred to physically dispense and deliver prescriptions (e.g., dispensing pharmacists' and technicians' salaries and costs of medication containers) and costs incurred to support the dispensing function (e.g., salaries of delivery and medical records personnel). A model based on dispensing-related fixed, variable, and semivariable costs was

  2. Oskarshamn site investigation. Hydrogeochemical monitoring programme for core and percussion drilled boreholes 2009. Summary of ground water chemistry results from spring and autumn sampling

    Energy Technology Data Exchange (ETDEWEB)

    Regander, Claes; Bergman, Bo (Sweco Environment AB (Sweden))

    2010-09-15

    This report summarises the results obtained in 2009 from the hydrogeochemical monitoring programme for core and percussion drilled boreholes. During 2009 groundwater sampling has been performed in monitored (permanently installed) boreholes in two sampling periods, spring (May-June), and autumn (October-November). Both in spring and autumn groundwater sampling was carried out in the following 12 sections; HLX28:2, HLX35:2, HLX37:1, HLX39:1, KLX08:4, KLX10:2, KLX10:5, KLX12A:2, KLX15A:3, KLX15A:6, KLX18A:3, KLX19A:3. The programme started in 2005 and since then water sampling has been performed twice every year. The objective of the hydrogeochemical monitoring programme is to determine the groundwater composition in selected sections chosen for this purpose. In 2009 the sampling of core drilled borehole sections has been conducted in time series, where each borehole section has been sampled at seven occasions. Percussion drilled borehole sections has been sampled at three occasions. The final sample in each section was taken when the electric conductivity had reached a stable level. Obtained results from the activities presented here include groundwater chemistry data in accordance with SKB chemistry class 5 including options and SKB chemistry reduced class 5. SKB chemistry reduced class 5 includes analysis of pH, electric conductivity, alkalinity, density, drill water (uranine), major cations (Chapter 5.4), F-, Br-, Cl-, SO{sub 4}2-, Fe(II)/Fe(tot), HS-, DOC, TOC and the isotopes delta2H, delta18O and 3H. Options for SKB chemistry class 5 include even lanthanoids and other trace elements, As, In, I, environmental metals, NH{sub 4}+, nutrient salts and the isotopes delta34S, delta37Cl, 87Sr/86Sr, 10B/11B, delta13C, 226Ra, 222Rn, 238U, 234U, 230Th and 232Th. All data from the activity are stored in the SICADA database

  3. Flow Channel Influence of a Collision-Based Piezoelectric Jetting Dispenser on Jet Performance

    Directory of Open Access Journals (Sweden)

    Can Zhou

    2018-04-01

    Full Text Available To improve the jet performance of a bi-piezoelectric jet dispenser, mathematical and simulation models were established according to the operating principle. In order to improve the accuracy and reliability of the simulation calculation, a viscosity model of the fluid was fitted to a fifth-order function with shear rate based on rheological test data, and the needle displacement model was fitted to a nine-order function with time based on real-time displacement test data. The results show that jet performance is related to the diameter of the nozzle outlet and the cone angle of the nozzle, and the impacts of the flow channel structure were confirmed. The approach of numerical simulation is confirmed by the testing results of droplet volume. It will provide a reliable simulation platform for mechanical collision-based jet dispensing and a theoretical basis for micro jet valve design and improvement.

  4. Integration of dispenser-printed ultra-low-voltage thermoelectric and energy storage devices

    International Nuclear Information System (INIS)

    Wang, Z; Chen, A; Winslow, R; Madan, D; Nill, M; Wright, P K; Juang, R C; Evans, J W

    2012-01-01

    This paper reports on an integrated energy harvesting prototype that consists of dispenser-printed thermoelectric energy harvesting and electrochemical energy storage devices. Parallel-connected thermoelectric devices with low internal resistances were designed, fabricated and characterized. The use of a commercially available dc-to-dc converter was explored to step-up a 27.1 mV input voltage from a printed thermoelectric device to a regulated 2.34 V output at a maximum of 34% conversion efficiency. The regulated power succeeds in charging dispenser-printed, zinc-based micro-batteries with charging efficiencies of up to 67%. The prototype presented in this work demonstrates the feasibility of deploying a printable, cost-effective and perpetual power solution for practical wireless sensor network applications. (paper)

  5. Microfluidic device and method for focusing, segmenting, and dispensing of a fluid stream

    Science.gov (United States)

    Jacobson, Stephen C [Knoxville, TN; Ramsey, J Michael [Knoxville, TN

    2008-09-09

    A microfluidic device and method for forming and dispensing minute volume segments of a material are described. In accordance with the present invention, a microfluidic device and method are provided for spatially confining the material in a focusing element. The device is also adapted for segmenting the confined material into minute volume segments, and dispensing a volume segment to a waste or collection channel. The device further includes means for driving the respective streams of sample and focusing fluids through respective channels into a chamber, such that the focusing fluid streams spatially confine the sample material. The device may also include additional means for driving a minute volume segment of the spatially confined sample material into a collection channel in fluid communication with the waste reservoir.

  6. Accurate, consistent, and fast droplet splitting and dispensing in electrowetting on dielectric digital microfluidics

    Science.gov (United States)

    Nikapitiya, N. Y. Jagath B.; Nahar, Mun Mun; Moon, Hyejin

    2017-12-01

    This letter reports two novel electrode design considerations to satisfy two very important aspects of EWOD operation—(1) Highly consistent volume of generated droplets and (2) Highly improved accuracy in the generated droplet volume. Considering the design principles investigated two novel designs were proposed; L-junction electrode design to offer high throughput droplet generation and Y-junction electrode design to split a droplet very fast while maintaining equal volume of each part. Devices of novel designs were fabricated and tested, and the results are compared with those of conventional approach. It is demonstrated that inaccuracy and inconsistency of droplet volume dispensed in the device with novel electrode designs are as low as 0.17 and 0.10%, respectively, while those of conventional approach are 25 and 0.76%, respectively. The dispensing frequency is enhanced from 4 to 9 Hz by using the novel design.

  7. Digital Imaging and Piezo-dispenser Actuator in Automatic Flocculation Control

    Directory of Open Access Journals (Sweden)

    Jani TOMPERI

    2012-01-01

    Full Text Available This study presents an image-based on-line control system for a coiled pipe flocculator. A digital imaging technique developed previously is utilized to measure the characteristic floc size and a high-pressure piezo-dispenser is introduced for accurate dosing and rapid mixing of the flocculant. The controller is a conventional PI controller. Step change experiments on feed water quality, flow rate and desired floc size have been carried out for controller tuning and testing. The paper shows that the piezo-dispenser provides better flocculation results than a conventional dosing pump, and the flocculation result can be automatically controlled even when the feed water quality rapidly changes. The proposed flocculator is a simple, inexpensive and practical system for long-term laboratory tests to investigate the functionality of flocculants on varying feed waters.

  8. Tarptautinio turizmo raida ir vystymo prognozės Lietuvoje ir Lenkijoje

    OpenAIRE

    Veličkaitė, Dalia

    2009-01-01

    Išanalizuota ir įvertinta Lietuvos ir Lenkijos atvykstamojo turizmo raida 2000- 2007m., užsienio turistų srautai, apgyvendinimo paslaugų paklausa, turistų tikslai ir kelionių transporto pasirinkimas, turistų išlaidos ir šalių turizmo pajamos, iškeltos atvykstamojo turizmo problemos bei pateikti jų sprendimo siūlymai.paskutinėje darbo dalyje buvo atliktos 2008- 2015metų Lietuvos ir Lenkijos turizmo raidos prognozės. In the final master work Lithuanian and Poland arriving tourism development...

  9. Validating a proxy for disease progression in metastatic cancer patients using prescribing and dispensing data.

    Science.gov (United States)

    Joshi, Vikram; Adelstein, Barbara-Ann; Schaffer, Andrea; Srasuebkul, Preeyaporn; Dobbins, Timothy; Pearson, Sallie-Anne

    2017-10-01

    Routine data collections are used increasingly to examine outcomes of real-world cancer drug use. These datasets lack clinical details about important endpoints such as disease progression. To validate a proxy for disease progression in metastatic cancer patients using prescribing and dispensing claims. We used data from a cohort study of patients undergoing chemotherapy who provided informed consent to the collection of cancer-treatment data from medical records and linkage to pharmaceutical claims. We derived proxy decision rules based on changes to drug treatment in prescription histories (n = 36 patients) and validated the proxy in prescribing data (n = 62 patients). We adapted the decision rules and validated the proxy in dispensing data (n = 109). Our gold standard was disease progression ascertained in patient medical records. Individual progression episodes were the unit of analysis for sensitivity and Positive Predictive Value (PPV) calculations and specificity and Negative Predictive Value (NPV) were calculated at the patient level. The sensitivity of our proxy in prescribing data was 74.3% (95% Confidence Interval (CI), 55.6-86.6%) and PPV 61.2% (95% CI, 45.0-75.3%); specificity and NPV were 87.8% (95% CI, 73.8-95.9%) and 100% (95% CI, 90.3-100%), respectively. In dispensing data, the sensitivity of our proxy was 64% (95% CI, 55.0-77.0%) and PPV 56.0% (95% CI, 43.0-69.0%); specificity and NPV were 81% (95% CI, 70.05-89.0%) and 91.0% (95% CI, 82.0-97.0%), respectively. Our proxy overestimated episodes of disease progression. The proxy's performance is likely to improve if the date of prescribing is used instead of date of dispensing in claims data and by incorporating medical service claims (such as imaging prior to drug changes) in the algorithm. Our proxy is not sufficiently robust for use in real world comparative effectiveness research for cancer medicines. © 2016 John Wiley & Sons Australia, Ltd.

  10. Care relationships at stake? Home healthcare professionals’ experiences with digital medicine dispensers – a qualitative study

    OpenAIRE

    Nakrem, Sigrid; Solbjør, Marit; Pettersen, Ida Nilstad; Kleiven, Hanne Hestvik

    2018-01-01

    Background Although digital technologies can mitigate the burdens of home healthcare services caused by an ageing population that lives at home longer with complex health problems, research on the impacts and consequences of digitalised remote communication between patients and caregivers is lacking. The present study explores how home healthcare professionals had experienced the introduction of digital medicine dispensers and their influence on patient-caregiver relationships. Methods...

  11. Subsidising patient dispensing fees: the cost of injecting equity into the opioid pharmacotherapy maintenance system.

    Science.gov (United States)

    Chalmers, Jenny; Ritter, Alison

    2012-11-01

    Australian pharmacotherapy maintenance programs incur costs to patients. These dispensing fees represent a financial burden to patients and are inconsistent with Australian health-care principles. No previous work has examined the current costs nor the future predicted costs if government subsidised dispensing fees. A system dynamics model, which simulated the flow of patients into and out of methadone maintenance treatment, was developed. Costs were imputed from existing research data. The approach enabled simulation of possible behavioural responses to a fee subsidy (such as higher retention) and new estimates of costs were derived under such scenarios. Current modelled costs (AUS$11.73m per month) were largely borne by state/territory government (43%), with patients bearing one-third (33%) of the total costs and the Commonwealth one-quarter (24%). Assuming no behavioural changes associated with fee subsidies, the cost of subsidising the dispensing fees of Australian methadone patients would be $3.9m per month. If retention were improved as a result of fee subsidy, treatment numbers would increase and the model estimates an additional cost of $0.8m per month. If this was coupled with greater numbers entering treatment, the costs would increase by a further $0.4m per month. In total, full fee subsidy with modelled behavioural changes would increase per annum government expenditure by $81.8m to $175.8m. If government provided dispensing fee relief for methadone maintenance patients, it would be a costly exercise. However, these additional costs are offset by the social and health gains achieved from the methadone maintenance program. © 2012 Australasian Professional Society on Alcohol and other Drugs.

  12. ASHP national survey of pharmacy practice in hospital settings: dispensing and administration--2011.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2012-05-01

    Results of the 2011 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are presented. A stratified random sample of pharmacy directors at 1401 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 40.1%. Decentralization of the medication-use system continues, with 40% of hospitals using a decentralized system and 58% of hospitals planning to use a decentralized model in the future. Automated dispensing cabinets were used by 89% of hospitals, robots were used by 11%, carousels were used in 18%, and machine-readable coding was used in 34% of hospitals to verify doses before dispensing. Overall, 65% of hospitals had a United States Pharmacopeia chapter 797 compliant cleanroom for compounding sterile preparations. Medication administration records (MARs) have become increasingly computerized, with 67% of hospitals using electronic MARs. Bar-code-assisted medication administration was used in 50% of hospitals, and 68% of hospitals had smart infusion pumps. Health information is becoming more electronic, with 67% of hospitals having partially or completely implemented an electronic health record and 34% of hospitals having computerized prescriber order entry. The use of these technologies has substantially increased over the past year. The average number of full-time equivalent staff per 100 occupied beds averaged 17.5 for pharmacists and 15.0 for technicians. Directors of pharmacy reported declining vacancy rates for pharmacists. Pharmacists continue to improve medication use at the dispensing and administration steps of the medication-use system. The adoption of new technology is changing the philosophy of medication distribution, and health information is rapidly becoming electronic.

  13. Concern about the Expanding Prescription Drug Epidemic: A Survey of Licensed Prescribers and Dispensers.

    Science.gov (United States)

    Wright, R Eric; Reed, Nia; Carnes, Neal; Kooreman, Harold E

    2016-01-01

    Prescription drug misuse and abuse has reached epidemic levels in the U.S., and stands as a leading cause of death. As the primary gatekeepers to the medications contributing to this epidemic, it is critical to understand the views of licensed health care professionals. In this study, we examine health care professionals' concern regarding prescription drug abuse in their communities and the impact their concern has had on their prescribing and dispensing practices. An online survey of licensed health care providers. Conducted in Indiana. This study was a state-wide evaluation of Indiana's prescription drug monitoring program. The questionnaire asked respondents how concerned they were about prescription drug abuse in their community. Variation in the level of concern was examined using ordinary least squares regression and information about the respondents' demographic background and clinical experience. In addition, we used logistic regression to examine whether concern was associated with changing prescribing and/or dispensing behavior. The majority of providers indicated they were "moderately" or "extremely concerned" about prescription drug abuse in their communities. The level of concern, however, varied significantly by profession, with pharmacists, physicians, nurse practitioners/physician assistants being more concerned than dentists. Additional analyses indicate that providers with higher levels of concern were those who also reported recently changing their prescribing and/or dispensing behavior. The voluntary nature and geographical focus of the study limits the generalizability of the findings. Concern about prescription drug abuse is generally high across the major health care professions; however, a significant minority of providers, particularly among dentists, expressed little or no concern about the epidemic. Increasing health care providers' general level of concern about prescription drug abuse may be an effective public health tool for

  14. Use of simulated patients to evaluate combined oral contraceptive dispensing practices of community pharmacists.

    Directory of Open Access Journals (Sweden)

    Paulo Roque Obreli-Neto

    Full Text Available BACKGROUND: Combined oral contraceptive (COC use is the most commonly used reversible method of birth control. The incorrect use of COCs is frequent and one of the most common causes of unintended pregnancies. Community pharmacists (CPs are in a strategic position to improve COC use because they are the last health professional to interact with patients before drug use. OBJECTIVE: To evaluate the COC dispensing practices of CPs in a developing country. METHOD: A cross-sectional study was conducted in community pharmacies of Assis and Ourinhos microregions, Brazil, between June 1, 2012, and October 30, 2012. Four simulated patients (SPs (with counseled audio recording visited community pharmacies with a prescription for Ciclo 21(® (a COC containing ethinyl estradiol 30 mcg + levonorgestrel 15 mcg. The audio recording of every SP visit was listened to independently by 3 researchers to evaluate the COC dispensing practice. The percentage of CPs who performed a screening for safe use of COCs (i.e., taking of patients' medical and family history, and measuring of blood pressure and provided counseling, as well as the quality of the screening and counseling, were evaluated. RESULTS: Of the 185 CPs contacted, 41 (22.2% agreed to participate in the study and finished the study protocol. Only 3 CPs asked the SP a question (1 question asked by each professional, and all of the questions were closed-ended, viz., "do you smoke?" (n = 2 and "what is your age?" (n = 1. None of the CPs measured the patient's blood pressure. Six CPs provided counseling when dispensing COCs (drug dosing, 5 CPs; possible adverse effects, 2 CPs, and one CP provided counseling regarding both aspects. CONCLUSION: The CPs evaluated did not dispense COC appropriately and could influence in the occurrence of negatives therapeutic outcomes such as adverse effects and treatment failure.

  15. Numerical Simulation Analysis of High-precision Dispensing Needles for Solid-liquid Two-phase Grinding

    Science.gov (United States)

    Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming

    2018-03-01

    In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.

  16. Raw Milk Hygiene at Local Markets and Automatic Milk Dispenser Machines

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available In Romania, direct sales of raw milk to the final consumer is developed based on the local regulations. These are in accordance to European Regulation that must meet some quality requirements for the total number of germs, somatic cells, without antibiotics, coming from healthy animals who did not suffer from diseases that can be transmitted to humans through milk. Raw milk is sold in Romania in local markets and by automatic milk dispenser machines. Based on these regulations, a study regarding the quality and security to human health of raw milk was conducted on the commercialized milk in local markets and automatic milk dispensers. During May-June 2014 samples of raw milk were collected from Cluj-Napoca local markets and automatic milk dispensers. All samples were kept to refrigeration conditions until the moment of analyze which took place at the sampling day. The following parameters were taken into account: fat content, protein, casein, lactose, nonfat dry matter, pH, milk freezing point, added water, antibiotics residues, milk urea, number of germ cells and somatic cells. All obtained results were verified by the validated methods applied. Our research can be forward conducted in order to verify the hygiene and composition of milk from the whole dairy chain. 

  17. Use of direct washing of chemical dispense nozzle for defect control

    Science.gov (United States)

    Linnane, Michael; Mack, George; Longstaff, Christopher; Winter, Thomas

    2006-03-01

    Demands for continued defect reduction in 300mm IC manufacturing are driving process engineers to examine all aspects of the chemical apply process for improvement. Historically, the defect contribution from photoresist apply nozzles has been minimized through a carefully controlled process of "dummy dispenses" to keep the photoresist in the tip "fresh" and remove any solidified material, a preventive maintenance regime involving periodic cleaning or replacing of the nozzles, and reliance on a pool of solvent within the nozzle storage block to keep the photoresist from solidifying at the nozzle tip. The industry standard has worked well for the most part but has limitations in terms of cost effectiveness and absolute defect elimination. In this study, we investigate the direct washing of the chemical apply nozzle to reduce defects seen on the coated wafer. Data is presented on how the direct washing of the chemical dispense nozzle can be used to reduce coating related defects, reduce material costs from the reduction of "dummy dispense", and can reduce equipment downtime related to nozzle cleaning or replacement.

  18. Measurement of microbic contamination rate in the dispensing process making suspension of barium sulfate powder

    International Nuclear Information System (INIS)

    Kim, Young Keun; Lee, Yang Sub; Cho, Cheong Chan; Ryu, Meung Sun; Lee, Kyung Sup

    2001-01-01

    The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus coli were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured. Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensable to manufacturing suspension for preventing from infection

  19. Immediate or deferred adjustment of drug regimens in multidose drug dispensing systems.

    Science.gov (United States)

    Mertens, Bram J; Kwint, Henk-Frans; van Marum, Rob J; Bouvy, Marcel L

    2018-05-18

    Multidose drug dispensing (MDD) is used to help patients take their medicines appropriately. Little is known about drug regimen changes within these MDD systems and how they are effectuated by the community pharmacist. Manual immediate adjustments of the MDD system could introduce dispensing errors. MDD guidelines therefore recommend to effectuate drug regimen changes at the start of a new MDD system. The aim of this study was to investigate the frequency, type, procedure followed, immediate necessity, and time taken to make MDD adjustments. This was a cross-sectional study in eight community pharmacies in the Netherlands. All adjustments to MDD systems were systematically documented for 3 weeks by the community pharmacist. Overall, 261 MDD adjustments involving 364 drug changes were documented for 250 patients: 127 (35%) drug changes involved the addition of a new drug, 124 (34%) a change in dosage, and 95 (26%) drug discontinuation. Of the MDD adjustments, 135 (52%) were effectuated immediately: 81 (31%) by adjusting the MDD system manually, 49 (19%) by temporarily dispensing the drug separately from the MDD system, and 5 (2%) by ordering a new MDD system. Pharmacists considered that 36 (27%) of the immediate MDD adjustments could have been deferred until the next MDD system was produced. Immediate adjustment took significantly longer than deferred adjustment (p < 0.001). This study shows that in patients using MDD systems, over half of the drug regimen changes are adjusted immediately. The necessity of these immediate changes should be critically evaluated. Copyright © 2018. Published by Elsevier Inc.

  20. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  1. Visualizing Infrared (IR) Spectroscopy with Computer Animation

    Science.gov (United States)

    Abrams, Charles B.; Fine, Leonard W.

    1996-01-01

    IR Tutor, an interactive, animated infrared (IR) spectroscopy tutorial has been developed for Macintosh and IBM-compatible computers. Using unique color animation, complicated vibrational modes can be introduced to beginning students. Rules governing the appearance of IR absorption bands become obvious because the vibrational modes can be visualized. Each peak in the IR spectrum is highlighted, and the animation of the corresponding normal mode can be shown. Students can study each spectrum stepwise, or click on any individual peak to see its assignment. Important regions of each spectrum can be expanded and spectra can be overlaid for comparison. An introduction to the theory of IR spectroscopy is included, making the program a complete instructional package. Our own success in using this software for teaching and research in both academic and industrial environments will be described. IR Tutor consists of three sections: (1) The 'Introduction' is a review of basic principles of spectroscopy. (2) 'Theory' begins with the classical model of a simple diatomic molecule and is expanded to include larger molecules by introducing normal modes and group frequencies. (3) 'Interpretation' is the heart of the tutorial. Thirteen IR spectra are analyzed in detail, covering the most important functional groups. This section features color animation of each normal mode, full interactivity, overlay of related spectra, and expansion of important regions. This section can also be used as a reference.

  2. Implementing a bar-code assisted medication administration system: effects on the dispensing process and user perceptions.

    Science.gov (United States)

    Samaranayake, N R; Cheung, S T D; Cheng, K; Lai, K; Chui, W C M; Cheung, B M Y

    2014-06-01

    We assessed the effects of a bar-code assisted medication administration system used without the support of computerised prescribing (stand-alone BCMA), on the dispensing process and its users. The stand-alone BCMA system was implemented in one ward of a teaching hospital. The number of dispensing steps, dispensing time and potential dispensing errors (PDEs) were directly observed one month before and eight months after the intervention. Attitudes of pharmacy and nursing staff were assessed using a questionnaire (Likert scale) and interviews. Among 1291 and 471 drug items observed before and after the introduction of the technology respectively, the number of dispensing steps increased from five to eight and time (standard deviation) to dispense one drug item by one staff personnel increased from 0.8 (0.09) to 1.5 (0.12) min. Among 2828 and 471 drug items observed before and after the intervention respectively, the number of PDEs increased significantly (Psystem offered less benefit to the dispensing process (9/16). Nursing staff perceived the system as useful in improving the accuracy of drug administration (7/10). Implementing a stand-alone BCMA system may slow down and complicate the dispensing process. Nursing staff believe the stand-alone BCMA system could improve the drug administration process but pharmacy staff believes the technology would be more helpful if supported by computerised prescribing. However, periodical assessments are needed to identify weaknesses in the process after implementation, and all users should be educated on the benefits of using this technology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. The role of pharmacists and emergency contraception: Are pharmacists' perceptions of emergency contraception predictive of their dispensing practices?

    Science.gov (United States)

    Richman, Alice R; Daley, Ellen M; Baldwin, Julie; Kromrey, Jeff; O'Rourke, Kathleen; Perrin, Kay

    2012-10-01

    Pharmacists can play a critical role in the access to emergency contraception (EC). We assessed if knowledge and attitudes were predictive of EC dispensing among a statewide sample of Florida pharmacists, who have legal authority to refuse to dispense medications. In 2008, surveys were mailed to a random sample of 1264 pharmacists registered with the Florida Board of Pharmacy. Data from 272 pharmacists (22% response rate) were analyzed using bivariate and multivariate logistic regression. Fifty-six percent of respondents incorrectly answered that EC causes birth defects, and 46% replied that it causes abortion. Only 22% said that EC can be purchased in advance of need. Many felt uncomfortable dispensing to adolescents (61%) and men (58%). Knowledge about EC was the most important predictor of dispensing [odds ratio (OR)=1.57, 95% confidence interval (CI) 1.22-2.03]. In particular, pharmacists who reported that EC does not act as an abortifacient were more likely to dispense it (OR=4.64, 95% CI 2.15-10.00). Correct information about EC was the most important predictor of pharmacists' dispensing EC. To expand availability of EC, pharmacists will have to become better informed. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Vartotojų lojalumas : formavimas ir valdymas

    OpenAIRE

    Zikienė, Kristina

    2010-01-01

    Vienas iš esminių daugelio organizacijų tikslų, garantuojančių tolesnį sėkmingą konkuravimą nuolat besikeičiančiame verslo pasaulyje, yra vartotojų lojalumo įgijimas ir išlaikymas. Įvairios lojalumo formavimo ir valdymo problemos plačiai ir detaliai analizuojamos šioje mokomojoje knygoje. Knyga pradedama vartotojų lojalumo analize marketingo mokslo raidos kontekste. Tolesnis dėmesys skiriamas vartotojų lojalumo vadybinio aspekto analizei, atskleidžiant vartotojų lojalumo koncepcijos teorines ...

  5. The TApIR experiment. IR absorption spectra of liquid hydrogen isotopologues; Das TApIR Experiment IR-Absorptionsspektren fluessiger Wasserstoffisotopologe

    Energy Technology Data Exchange (ETDEWEB)

    Groessle, Robin

    2015-11-27

    The scope of the thesis is the infrared absorption spectroscopy of liquid hydrogen isotopologues with the tritium absorption infrared spectroscopy (TApIR) experiment at the tritium laboratory Karlsruhe (TLK). The calibration process from the sample preparation to the reference measurements are described. A further issue is the classical evaluation of FTIR absorption spectra and the extension using the rolling circle filter (RCF) including the effects on statistical and systematical errors. The impact of thermal and nuclear spin temperature on the IR absorption spectra is discussed. An empirical based modeling for the IR absorption spectra of liquid hydrogen isotopologues is performed.

  6. Increasing Access to Subsidized Artemisinin-based Combination Therapy through Accredited Drug Dispensing Outlets in Tanzania

    Directory of Open Access Journals (Sweden)

    Gabra Michael

    2011-06-01

    Full Text Available Abstract Background In Tanzania, many people seek malaria treatment from retail drug sellers. The National Malaria Control Program identified the accredited drug dispensing outlet (ADDO program as a private sector mechanism to supplement the distribution of subsidized artemisinin-based combination therapies (ACTs from public facilities and increase access to the first-line antimalarial in rural and underserved areas. The ADDO program strengthens private sector pharmaceutical services by improving regulatory and supervisory support, dispenser training, and record keeping practices. Methods The government's pilot program made subsidized ACTs available through ADDOs in 10 districts in the Morogoro and Ruvuma regions, covering about 2.9 million people. The program established a supply of subsidized ACTs, created a price system with a cost recovery plan, developed a plan to distribute the subsidized products to the ADDOs, trained dispensers, and strengthened the adverse drug reactions reporting system. As part of the evaluation, 448 ADDO dispensers brought their records to central locations for analysis, representing nearly 70% of ADDOs operating in the two regions. ADDO drug register data were available from July 2007-June 2008 for Morogoro and from July 2007-September 2008 for Ruvuma. This intervention was implemented from 2007-2008. Results During the pilot, over 300,000 people received treatment for malaria at the 448 ADDOs. The percentage of ADDOs that dispensed at least one course of ACT rose from 26.2% during July-September 2007 to 72.6% during April-June 2008. The number of malaria patients treated with ACTs gradually increased after the start of the pilot, while the use of non-ACT antimalarials declined; ACTs went from 3% of all antimalarials sold in July 2007 to 26% in June 2008. District-specific data showed substantial variation among the districts in ACT uptake through ADDOs, ranging from ACTs representing 10% of all antimalarial sales

  7. PKCδ-mediated IRS-1 Ser24 phosphorylation negatively regulates IRS-1 function

    International Nuclear Information System (INIS)

    Greene, Michael W.; Ruhoff, Mary S.; Roth, Richard A.; Kim, Jeong-a; Quon, Michael J.; Krause, Jean A.

    2006-01-01

    The IRS-1 PH and PTB domains are essential for insulin-stimulated IRS-1 Tyr phosphorylation and insulin signaling, while Ser/Thr phosphorylation of IRS-1 disrupts these signaling events. To investigate consensus PKC phosphorylation sites in the PH-PTB domains of human IRS-1, we changed Ser24, Ser58, and Thr191 to Ala (3A) or Glu (3E), to block or mimic phosphorylation, respectively. The 3A mutant abrogated the inhibitory effect of PKCδ on insulin-stimulated IRS-1 Tyr phosphorylation, while reductions in insulin-stimulated IRS-1 Tyr phosphorylation, cellular proliferation, and Akt activation were observed with the 3E mutant. When single Glu mutants were tested, the Ser24 to Glu mutant had the greatest inhibitory effect on insulin-stimulated IRS-1 Tyr phosphorylation. PKCδ-mediated IRS-1 Ser24 phosphorylation was confirmed in cells with PKCδ catalytic domain mutants and by an RNAi method. Mechanistic studies revealed that IRS-1 with Ala and Glu point mutations at Ser24 impaired phosphatidylinositol-4,5-bisphosphate binding. In summary, our data are consistent with the hypothesis that Ser24 is a negative regulatory phosphorylation site in IRS-1

  8. Activity uniformity of Ir-192 seeds

    International Nuclear Information System (INIS)

    Ling, C.C.; Gromadzki, Z.C.

    1981-01-01

    A simple device that uses materials and apparatus commonly available in a radiotherapy department has been designed, fabricated and used in routine quality control relative to the activity uniformity of clinical Ir-192 seeds in ribbons. Detailed evaluation indicated that this system is easy to use and can yield relative activity measurements of individual Ir-192 seeds accurate to within 2%. With this device, activity uniformity of commercial Ir-192 seeds from two manufacturers has been assessed. For the seven shipments of Ir-192 seeds studied, the root mean square variations of individual seed strength from the average of each shipment ranged from 3.4 to 7.1%. Variation in seed activity by more than +- 10% from the average is not uncommon

  9. Implementing GPS into Pave-IR.

    Science.gov (United States)

    2009-03-01

    To further enhance the capabilities of the Pave-IR thermal segregation detection system developed at the Texas Transportation Institute, researchers incorporated global positioning system (GPS) data collection into the thermal profiles. This GPS capa...

  10. Joint IAEA/NEA IRS guidelines

    International Nuclear Information System (INIS)

    1997-01-01

    The Incident Reporting System (IRS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organization for Economic Cooperation and Development (OECD/NEA). The fundamental objective of the IRS is to contribute to improving the safety of commercial nuclear power plants (NPPs) which are operated worldwide. This objective can be achieved by providing timely and detailed information on both technical and human factors related to events of safety significance which occur at these plants. The purpose of these guidelines, which supersede the previous IAEA Safety Series No. 93 (Part II) and the NEA IRS guidelines, is to describe the system and to give users the necessary background and guidance to enable them to produce IRS reports meeting a high standard of quality while retaining the high efficiency of the system expected by all Member States operating nuclear power plants

  11. Understanding the Role of Accredited Drug Dispensing Outlets in Tanzania's Health System.

    Directory of Open Access Journals (Sweden)

    Martha Embrey

    Full Text Available People in many low-income countries access medicines from retail drug shops. In Tanzania, a public-private partnership launched in 2003 used an accreditation approach to improve access to quality medicines and pharmaceutical services in underserved areas. The government scaled up the accredited drug dispensing outlet (ADDO program nationally, with over 9,000 shops now accredited. This study assessed the relationships between community members and their sources of health care and medicines, particularly antimicrobials, with a specific focus on the role ADDOs play in the health care system.Using mixed methods, we collected data in four regions. We surveyed 1,185 households and audited 96 ADDOs and 84 public/nongovernmental health facilities using a list of 17 tracer drugs. To determine practices in health facilities, we interviewed 1,365 exiting patients. To assess dispensing practices, mystery shoppers visited 306 ADDOs presenting one of three scenarios (102 each about a child's respiratory symptoms.Of 614 household members with a recent acute illness, 73% sought outside care-30% at a public facility and 31% at an ADDO. However, people bought medicines more often at ADDOs no matter who recommended the treatment; of the 581 medicines that people had received, 49% came from an ADDO. Although health facilities and ADDOs had similar availability of antimicrobials, ADDOs had more pediatric formulations available (p<0.001. The common perception was that drugs from ADDOs are more expensive, but the difference in the median cost to treat pneumonia was relatively minimal (US$0.26 in a public facility and US$0.30 in an ADDO. Over 20% of households said they had someone with a chronic condition, with 93% taking medication, but ADDOs are allowed to sell very few chronic care-related medicines. ADDO dispensers are trained to refer complicated cases to a health facility, and notably, 99% of mystery shoppers presenting a pneumonia scenario received an

  12. ASHP national survey of pharmacy practice in hospital settings: Dispensing and administration--2014.

    Science.gov (United States)

    Pedersen, Craig A; Schneider, Philip J; Scheckelhoff, Douglas J

    2015-07-01

    The results of the 2014 ASHP national survey of pharmacy practice in hospital settings that pertain to dispensing and administration are described. A stratified random sample of pharmacy directors at 1435 general and children's medical-surgical hospitals in the United States were surveyed by mail. In this national probability sample survey, the response rate was 29.7%. Ninety-seven percent of hospitals used automated dispensing cabinets in their medication distribution systems, 65.7% of which used individually secured lidded pockets as the predominant configuration. Overall, 44.8% of hospitals used some form of machine-readable coding to verify doses before dispensing in the pharmacy. Overall, 65% of hospital pharmacy departments reported having a cleanroom compliant with United States Pharmacopeia chapter 797. Pharmacists reviewed and approved all medication orders before the first dose was administered, either onsite or by remote order view, except in procedure areas and emergency situations, in 81.2% of hospitals. Adoption rates of electronic health information have rapidly increased, with the widespread use of electronic health records, computer prescriber order entry, barcodes, and smart pumps. Overall, 31.4% of hospitals had pharmacists practicing in ambulatory or primary care clinics. Transitions-of-care services offered by the pharmacy department have generally increased since 2012. Discharge prescription services increased from 11.8% of hospitals in 2012 to 21.5% in 2014. Approximately 15% of hospitals outsourced pharmacy management operations to a contract pharmacy services provider, an increase from 8% in 2011. Health-system pharmacists continue to have a positive impact on improving healthcare through programs that improve the efficiency, safety, and clinical outcomes of medication use in health systems. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  13. Polymer dispensing and embossing technology for the lens type LED packaging

    Science.gov (United States)

    Chien, Chien-Lin Chang; Huang, Yu-Che; Hu, Syue-Fong; Chang, Chung-Min; Yip, Ming-Chuen; Fang, Weileun

    2013-06-01

    This study presents a ring-type micro-structure design on the substrate and its corresponding micro fabrication processes for a lens-type light-emitting diode (LED) package. The dome-type or crater-type silicone lenses are achieved by a dispensing and embossing process rather than a molding process. Silicone with a high viscosity and thixotropy index is used as the encapsulant material. The ring-type micro structure is adopted to confine the dispensed silicone encapsulant so as to form the packaged lens. With the architecture and process described, this LED package technology herein has three merits: (1) the flexibility of lens-type LED package designs is enhanced; (2) a dome-type package design is used to enhance the intensity; (3) a crater-type package design is used to enhance the view angle. Measurement results show the ratio between the lens height and lens radius can vary from 0.4 to 1 by changing the volume of dispensed silicone. The view angles of dome-type and crater-type packages can reach 155° ± 5° and 175° ± 5°, respectively. As compared with the commercial plastic leaded chip carrier-type package, the luminous flux of a monochromatic blue light LED is improved by 15% by the dome-type package (improved by 7% by the crater-type package) and the luminous flux of a white light LED is improved by 25% by the dome-type package (improved by 13% by the crater-type package). The luminous flux of monochromatic blue light LED and white light LED are respectively improved by 8% and 12% by the dome-type package as compare with the crater-type package.

  14. Steam sterilization and automatic dispensing of [{sup 18}F]fludeoxyglucose (FDG) for injection

    Energy Technology Data Exchange (ETDEWEB)

    Karwath, Pascal [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany); Sartor, Johannes [MC-Pharma GmbH (MCP), Bonn (Germany); Gries, Wolfgang [MC-Pharma GmbH (MCP), Bonn (Germany); Wodarski, Christine [MC-Pharma GmbH (MCP), Bonn (Germany); Dittmar, Claus [MC-Pharma GmbH (MCP), Bonn (Germany); Biersack, Hans J [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Guhlke, Stefan [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany)

    2005-04-01

    For the purpose of implementing steam sterilization of 2-[{sup 18}F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity ({approx}99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories.

  15. Steam sterilization and automatic dispensing of [18F]fludeoxyglucose (FDG) for injection

    International Nuclear Information System (INIS)

    Karwath, Pascal; Sartor, Johannes; Gries, Wolfgang; Wodarski, Christine; Dittmar, Claus; Biersack, Hans J.; Guhlke, Stefan

    2005-01-01

    For the purpose of implementing steam sterilization of 2-[ 18 F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity (∼99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories

  16. Control of microbial contamination in drinking water from microfiltering dispensers by dialysis ultrafilters

    Directory of Open Access Journals (Sweden)

    Bolelli Luca

    2016-12-01

    Full Text Available Tap water filtering devices are widely employed to improve odor and taste of tap water, or to obtain refrigerated or sparkling drinking water. The presence of disinfectants-resistant bacteria in tap water is responsible of the biofilm formation inside tubes and tanks. The consequent contamination of dispensed water is a well-known hygiene problem because of the quite constant presence of potentially pathogenic bacteria likes P. aeruginosa. In this study, we tested the technical feasibility and effectiveness of the addition to different commercial devices of a packaged polysulphone fibers filter. We aimed to find a simple solution to implement the quality of the delivered water. Water contamination levels were determined in a wide selection of microfiltered water dispensers and we selected among them a representative group of 10 devices, new or in use. The packaged ultrafilter was introduced in about half of them, to monitor, when possible, in parallel the contamination levels and flow rate of a couple of identical units, with and without the filter. The placement of the dialysis filters resulted feasible at different positions along the water circuits of the variously designed filtration units. Delivered water resulted completely free from bacteria when the filter was placed exactly at, or very close to, the outlet in spite of the inner surfaces contamination. This performance was not obtained in presence of a more or less long tract of water circuits downstream the ultrafilter: a significant but not complete reduction of the plate count numbers was observed. The filters worked in continue over the whole study period, ten months, showing exactly the same efficiency. Moreover, the flow rate in presence of the filter was quite unaffected. The addition of this kind of filter to already in use water dispensers was technically easy, and its use can be recommended in all cases a simple but reliable water sanitization is requested.

  17. Using Multispectral Imaging to Measure Temperature Profiles and Emissivity of Large Thermionic Dispenser, Cathodes

    International Nuclear Information System (INIS)

    Simmons, D.F.; Fortgang, C.M.; Holtkamp, D.B.

    2001-01-01

    Thermionic dispenser cathodes are widely used in modern high-power microwave tubes. Use of these cathodes has led to significant improvement in performance. In recent years these cathodes have been used in electron linear accelerators (LINACs), particularly in induction LINACs, such as the Experimental Test Accelerator at Lawrence Livermore National Laboratory and the Relativistic Test Accelerator at Lawrence Berkeley National Laboratory. For induction LINACs, the thermionic dispenser cathode provides greater reproducibility, longer pulse lengths, and lower emittance beams than does a field emission cathode. Los Alamos National Laboratory is fabricating a dual-axis X-ray radiography machine called dual-axis radiograph hydrodynamic test (DARHT). The second axis of DARHT consists of a 2-kA, 20-MeV induction LINAC that uses a 3.2-MeV electron gun with a tungsten thermionic-dispenser cathode. Typically the DARHT cathode current density is 10 A/cm 2 at 1050 C. Under these conditions current density is space-charge limited, which is desirable since current density is independent of temperature. At lower temperature (the temperature-limited regime) there are variations in the local current density due to a nonuniform temperature profile. To obtain the desired uniform current density associated with space-charge limited operation, the coolest area on the cathode must be at a sufficiently high temperature so that the emission is space-charge limited. Consequently, the rest of the cathode is emitting at the same space-charge-limited current density but is at a higher temperature than necessary. Because cathode lifetime is such a strong function of cathode temperature, there is a severe penalty for nonuniformity in the cathode temperature. For example, a temperature increase of 50 C means cathode lifetime will decrease by a factor of at least four. Therefore, we are motivated to measure the temperature profiles of our large-area cathodes

  18. Evaluation of antibiotics dispensing profile in Tubarão, Santa Catarina, Brazil

    Directory of Open Access Journals (Sweden)

    Claudia Rauber

    2009-12-01

    Full Text Available Antibiotics are drugs widely used in prophylaxis and treatment of a great number of diseases. However, their use must be carefully controlled as acquisition in pharmacies, often without medical prescription, is elevated. The role of pharmacists in these circumstances is to practice dispensation in a rational manner. Through a structured questionnaire with open and closed questions, this study investigated the profile of antibiotics dispensed in pharmacies of Tubarão, Santa Catarina, Brazil. From the responses, it was observed that 85.0% dispense this class of medicine without medical prescription, mainly for treatment of respiratory (62.8% and urinary (12.0% tract disorders. Moreover, pharmacists' guidance was largely focused on posology (66.6% and drug interaction (12.6%, in addition to the interactions with contraceptives, alcohol and milk. The importance of avoiding antibiotics dispensation without medical prescription must be emphasized, as well as the benefits of educating the population to promote the rational use of medicines.Antibióticos são fármacos amplamente utilizados na profilaxia e no tratamento de grande número de doenças. Entretanto, seu uso deve ser cuidadosamente controlado nas farmácias, uma vez que nestas a aquisição sem prescrição médica é elevada. O papel dos farmacêuticos nessas circunstâncias é o de praticar a dispensação de maneira racional. Por meio de questionário estruturado, com questões abertas e fechadas, investigou-se o perfil dos antibióticos dispensados em farmácias de Tubarão, Santa Catarina, Brasil. Pelas respostas, observou-se que 85% das dispensa essa classe de medicamentos sem prescrição médica, principalmente para o tratamento de problemas dos tratos respiratório (62,8% e urinário (12,0%. Além disso, a orientação dos farmacêuticos se focou amplamente na posologia (66,6%e nas interações com fármacos (12,6%, em adição às interações com anticoncepcionais, álcool e

  19. A model for drug dispensing service based on the care process in the Brazilian health system

    Directory of Open Access Journals (Sweden)

    Luciano Soares

    2013-03-01

    Full Text Available Access to medication emphasizes the availability of the product at the expense of providing a service. The goal of this paper is to propose a theoretical model for a drug dispensing service, beginning with a reflection on the current realities of the Unified Health System and drug dispensation in Brazil. A conceptual analytical research made by a methodological course called disciplined imagination was mainly the approach applied to develop the model. The drug dispensing service is part of the care process, which considers access as an attribute; reception, connection and accountability, management, and clinical pharmaceutical aspects as components; and the rational use of drugs as the purpose. The proposed model addresses access to the dispensing service and demands a reorientation of routines, instruments, and practices.O acesso a medicamentos enfatiza a disponibilidade do produto em detrimento da provisão de um serviço. O objetivo deste trabalho é propor um modelo teórico para um serviço de dispensação de medicamentos, iniciando com uma reflexão sobre a realidade atual do Sistema Único de Saúde e a dispensação de medicamentos no Brasil. Uma pesquisa analítica conceitual realizada por meio de um percurso metodológico chamado de imaginação disciplinada constituiu a estratégia principal para o desenvolvimento do modelo. O serviço de dispensação é parte do processo de cuidado, o qual considera o acesso como um atributo; os aspectos acolhimento, vínculo e responsabilização, gestão e clínica farmacêutica como componentes e o uso racional de medicamentos como o propósito. O modelo proposto direciona o acesso para o serviço de dispensação e demanda a reorientação de rotinas, instrumentos e práticas.

  20. Gene disruption reveals a dispensable role for plasmepsin VII in the Plasmodium berghei life cycle.

    Science.gov (United States)

    Mastan, Babu S; Kumari, Anchala; Gupta, Dinesh; Mishra, Satish; Kumar, Kota Arun

    2014-06-01

    Plasmepsins (PM), aspartic proteases of Plasmodium, comprises a family of ten proteins that perform critical functions in Plasmodium life cycle. Except VII and VIII, functions of the remaining plasmepsin members have been well characterized. Here, we have generated a mutant parasite lacking PM VII in Plasmodium berghei using reverse genetics approach. Systematic comparison of growth kinetics and infection in both mosquito and vertebrate host revealed that PM VII depleted mutants exhibited no defects in development and progressed normally throughout the parasite life cycle. These studies suggest a dispensable role for PM VII in Plasmodium berghei life cycle. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Drug dispensing practices at pharmacies in Bengaluru: A cross-sectional study

    OpenAIRE

    R Soumya; Vijayalakshmi Devarashetty; C R Jayanthi; M Sushma

    2016-01-01

    Objectives: Pharmacists are one of the crucial focal points for health care in the community. They have tremendous outreach to the public as pharmacies are often the first-port-of-call. With the increase of ready-to-use drugs, the main health-related activity of a pharmacist today is to assure the quality of dispensing, a key element to promote rational medicine use. Materials and Methods: A cross-sectional study of 200 pharmacies, 100 each in various residential (R) and commercial (C) areas ...

  2. International Space Station (ISS) Potable Water Dispenser (PWD) Beverage Adapter (BA) Redesign

    Science.gov (United States)

    Edgerly, Rachel; Benoit, Jace; Shindo, David

    2012-01-01

    The Potable Water Dispenser used on the International Space Station (ISS) interfaces with food and drink packages using the Beverage Adapter and Needle. Unexpected leakage has been seen in this interface. The Beverage Adapter used on ]orbit was returned to the ground for Test, Teardown, and Evaluation. The results of that investigation prompted a redesign of the Beverage Adapter and Needle. The Beverage Adapter materials were changed to be more corrosion resistant, and the Needle was redesigned to preclude leakage. The redesigns have been tested and proven.

  3. Iridium Interfacial Stack - IrIS

    Science.gov (United States)

    Spry, David

    2012-01-01

    Iridium Interfacial Stack (IrIS) is the sputter deposition of high-purity tantalum silicide (TaSi2-400 nm)/platinum (Pt-200 nm)/iridium (Ir-200 nm)/platinum (Pt-200 nm) in an ultra-high vacuum system followed by a 600 C anneal in nitrogen for 30 minutes. IrIS simultaneously acts as both a bond metal and a diffusion barrier. This bondable metallization that also acts as a diffusion barrier can prevent oxygen from air and gold from the wire-bond from infiltrating silicon carbide (SiC) monolithically integrated circuits (ICs) operating above 500 C in air for over 1,000 hours. This TaSi2/Pt/Ir/Pt metallization is easily bonded for electrical connection to off-chip circuitry and does not require extra anneals or masking steps. There are two ways that IrIS can be used in SiC ICs for applications above 500 C: it can be put directly on a SiC ohmic contact metal, such as Ti, or be used as a bond metal residing on top of an interconnect metal. For simplicity, only the use as a bond metal is discussed. The layer thickness ratio of TaSi2 to the first Pt layer deposited thereon should be 2:1. This will allow Si from the TaSi2 to react with the Pt to form Pt2Si during the 600 C anneal carried out after all layers have been deposited. The Ir layer does not readily form a silicide at 600 C, and thereby prevents the Si from migrating into the top-most Pt layer during future anneals and high-temperature IC operation. The second (i.e., top-most) deposited Pt layer needs to be about 200 nm to enable easy wire bonding. The thickness of 200 nm for Ir was chosen for initial experiments; further optimization of the Ir layer thickness may be possible via further experimentation. Ir itself is not easily wire-bonded because of its hardness and much higher melting point than Pt. Below the iridium layer, the TaSi2 and Pt react and form desired Pt2Si during the post-deposition anneal while above the iridium layer remains pure Pt as desired to facilitate easy and strong wire-bonding to the Si

  4. Neuronal Cell Death Induced by Mechanical Percussion Trauma in Cultured Neurons is not Preceded by Alterations in Glucose, Lactate and Glutamine Metabolism.

    Science.gov (United States)

    Jayakumar, A R; Bak, L K; Rama Rao, K V; Waagepetersen, H S; Schousboe, A; Norenberg, M D

    2016-02-01

    Traumatic brain injury (TBI) is a devastating neurological disorder that usually presents in acute and chronic forms. Brain edema and associated increased intracranial pressure in the early phase following TBI are major consequences of acute trauma. On the other hand, neuronal injury, leading to neurobehavioral and cognitive impairments, that usually develop months to years after single or repetitive episodes of head trauma, are major consequences of chronic TBI. The molecular mechanisms responsible for TBI-induced injury, however, are unclear. Recent studies have suggested that early mitochondrial dysfunction and subsequent energy failure play a role in the pathogenesis of TBI. We therefore examined whether oxidative metabolism of (13)C-labeled glucose, lactate or glutamine is altered early following in vitro mechanical percussion-induced trauma (5 atm) to neurons (4-24 h), and whether such events contribute to the development of neuronal injury. Cell viability was assayed using the release of the cytoplasmic enzyme lactate dehydrogenase (LDH), together with fluorescence-based cell staining (calcein and ethidium homodimer-1 for live and dead cells, respectively). Trauma had no effect on the LDH release in neurons from 1 to 18 h. However, a significant increase in LDH release was detected at 24 h after trauma. Similar findings were identified when traumatized neurons were stained with fluorescent markers. Additionally (13)C-labeling of glutamate showed a small, but statistically significant decrease at 14 h after trauma. However, trauma had no effect on the cycling ratio of the TCA cycle at any time-period examined. These findings indicate that trauma does not cause a disturbance in oxidative metabolism of any of the substrates used for neurons. Accordingly, such metabolic disturbance does not appear to contribute to the neuronal death in the early stages following trauma.

  5. Impact of one-dose package dispensing with patient counseling on medication adherence in geriatrics suffering from chronic disorders

    Directory of Open Access Journals (Sweden)

    Narayana Goruntla

    2018-01-01

    Full Text Available Introduction: Medication nonadherence in elderly patients could result in a waste of medical expenses in a long-time span as well as deterioration of the patient's medical condition. Aim: The aim of this study is to evaluate the impact of one-dose package dispensing with patient counseling on medication adherence among elderly patients suffering from chronic disorders. Settings and Design: This is prospective, open-labeled, randomized trial carried out at dispensing pharmacy of the secondary care referral hospital, located in resource-limited settings of Anantapur District, Andhra Pradesh, India. Subjects and Methods: A total of 330 (aged ≥60 years patients were randomly assigned to one of three study groups: Group A (n = 110, no change in dosing and packing; Group B (n = 110, one-dose package dispensing; Group C (n = 110, One-dose package dispensing with patient counseling. Medication adherence levels were measured using a pill count and visual analog scale (VAS method at baseline and follow-up (after 1 month. Statistical Analysis: Descriptive statistics were used to represent the sociodemographic, clinical, and medication adherence profile of study participants. One-way ANOVA test is used to assess significant differences between three groups with a P 60 years who are on multiple medications can benefit from one-dose package dispensing and appropriate counseling. This will improve medication adherence hence better outcomes.

  6. College Cafeteria Signage Increases Water Intake but Water Position on the Soda Dispenser Encourages More Soda Consumption.

    Science.gov (United States)

    Montuclard, Astrid Linn; Park-Mroch, Jennifer; O'Shea, Amy M J; Wansink, Brian; Irvin, Jill; Laroche, Helena H

    2017-10-01

    To evaluate the effects of improved water location visibility and water dispenser position on the soda dispenser on undergraduate students' beverage choices. Two focus groups with pilot intervention surveys before and after, adding a small sign above the soda dispensers' water button for 6 weeks in a large US university's all-you-can-eat, prepaid dining hall (measured with chi-square tests and logistic and ordinal logistic regression). Focus groups included 15 students. Survey participants included 357 students before and 301 after the intervention. After the intervention, more students reported ever having drunk water with the meal (66.4% to 77.0%; P = .003) and water consumption frequency increased (P = .005). Postintervention, the odds of drinking water increased by 1.57. Preference for other drinks was the main reason for not drinking water. A total of 59% of students had ever changed their preference from water to soda. The clear indication of the water's location increased students' reported water consumption. Further investigation is needed into how a non-independent water dispenser influences students' beverage choice. Clearly labeled, independent water dispensers are recommended. Copyright © 2017 Society for Nutrition Education and Behavior. All rights reserved.

  7. Providers′ knowledge, attitude and dispensing practices of E-Pills in government dispensaries of south district in Delhi, India

    Directory of Open Access Journals (Sweden)

    Kishore Vertika

    2010-01-01

    Full Text Available Background: South Delhi is one of the well developed districts in the capital with best public health care facilities. Knowledge, attitude and dispensing practices of emergency contraceptive pills (E-pills were assessed among health care providers of government dispensaries in South Delhi. Study Design: A descriptive epidemiological study. Materials and Methods: Both medical and paramedical (n = 428 providers in 63 government health care facilities were interviewed between August to December 2007 using a semi-structured interview schedule. Results: Among the different categories of the providers, medical officers were observed to be most knowledgeable about E-pills and the pharmacists were the least. The correct prescribed dose of E-pill was known only to 32% of the providers while 49% knew about its right time of intake. Misconceptions and apprehensions for promoting its use were very much prevalent even among medical officers as majority felt that open access to E-pills would increase promiscuity. The dispensing practice of providers was found positively ( P < 0.05 correlated with their knowledge. Training resulted a significant ( P < 0.05 improvement in knowledge, attitude and dispensing practice of the providers. Knowledge and training combined together contributed 35% to the dispensing practice (R 2 = 0.35. Conclusion: Besides knowledge, behavior change communication strategies should form a part of the training curricula of health care providers that would help to improve the dispensing practice of E-pills.

  8. A Review of the Anthropometric Characteristics, Grading and Dispensation of Junior and Youth Rugby Union Players in Australia.

    Science.gov (United States)

    Patton, Declan Alexander; McIntosh, Andrew Stuart; Denny, Greg

    2016-08-01

    The grading of Australian junior and youth rugby union players has received substantial media attention in recent years. Media reports have focussed on size mismatches observed between players, especially players with Polynesian heritage, and the concerned parents who fear for the safety of their child owing to perceived mismatches. Although such concerns are well meaning, few media reports recognise the need for substantial evidence to determine the best grading system for junior and youth rugby union players. The current study reviewed relevant literature pertinent to the grading and dispensation of junior and youth rugby union players. Using primary and secondary search strategies, a total of 33 articles reporting the anthropometric characteristics of junior and youth rugby players were identified. Anthropometric data from the literature were compared with normative population data and currently used dispensation criteria. Junior and youth rugby players were found to be taller and heavier than normative population data. Current dispensation criteria, in terms of body mass, were found to vary and it is suggested that criteria be revised and standardised across rugby unions throughout Australia. Although it is acknowledged that other factors are important for grading players, anthropometric characteristics should be considered as potential dispensation criteria to supplement current age-based grading for junior and youth rugby union players. Measuring the body mass and stature of each junior player upon pre-season registration is suggested, which would provide data to establish valid dispensation criteria for the following season.

  9. Recent trends in the dispensing of 90-day-supply prescriptions at retail pharmacies: implications for improved convenience and access.

    Science.gov (United States)

    Liberman, Joshua N; Girdish, Charmaine

    2011-03-01

    Mail-service pharmacies offer consumers the convenience of prescriptions filled with a 90-day supply of medication. Unlike mail-service pharmacies, retail pharmacies traditionally dispensed maintenance medication prescriptions with a 30-day supply. However, the retail landscape changed in May 2008 with Walmart's announcement of an extension of its $4 Prescription Program to include 90-day-supply prescriptions. To evaluate recent changes in access to and use of 90-day-supply maintenance medications dispensed via retail pharmacy. As of the first quarter of 2007, the proportion of retail-dispensed maintenance medications with a 90-day supply (compared with all maintenance prescriptions dispensed) among Medicare Part D plans, self-insured employers, and private health plans was 5.1%, 5.1%, and 5.0%, respectively. As of December 2009, this ratio had risen to 8.0% for Medicare plans and 8.1% for commercial health plans; the ratio among employers had risen more modestly to 6.1%. Of particular interest and importance, the proportion increased similarly for brand and for generic medications. There has been substantial growth in 90-day prescriptions dispensed via retail pharmacy, a trend that is likely to continue as more insurance providers adopt compatible benefit designs. It is important to continue monitoring these trends and to identify opportunities to rigorously evaluate their impact on medication adherence and healthcare costs.

  10. Suppression of superconductivity in Nb by IrMn in IrMn/Nb bilayers

    KAUST Repository

    Wu, B. L.; Yang, Y. M.; Guo, Z. B.; Wu, Y. H.; Qiu, J. J.

    2013-01-01

    Effect of antiferromagnet on superconductivity has been investigated in IrMn/Nb bilayers. Significant suppression of both transition temperature (Tc) and lower critical field (Hc1) of Nb is found in IrMn/Nb bilayers as compared to a single layer Nb

  11. Single-nucleotide polymorphism of INS, INSR, IRS1, IRS2, PPAR-G ...

    Indian Academy of Sciences (India)

    2017-03-02

    Mar 2, 2017 ... Abstract. Polycystic ovary syndrome (PCOS) is the most common and a complex female endocrine disorder, and is one of the leading cause of female infertility. Here, we aimed to investigate the association of single-nucleotide polymorphism of INS, INSR,. IRS1, IRS2, PPAR-G and CAPN10 gene in the ...

  12. Effect of holed reflector on acoustic radiation force in noncontact ultrasonic dispensing of small droplets

    Science.gov (United States)

    Tanaka, Hiroki; Wada, Yuji; Mizuno, Yosuke; Nakamura, Kentaro

    2016-06-01

    We investigated the fundamental aspects of droplet dispensing, which is an important procedure in the noncontact ultrasonic manipulation of droplets in air. A holed reflector was used to dispense a droplet from a 27.4 kHz standing-wave acoustic field to a well. First, the relationship between the hole diameter of the reflector and the acoustic radiation force acting on a levitated droplet was clarified by calculating the acoustic impedance of the point just above the hole. When the hole diameter was half of (or equal to) the acoustic wavelength λ, the acoustic radiation force was ∼80% (or 50%) of that without a hole. The maximal diameters of droplets levitated above the holes through flat and half-cylindrical reflectors were then experimentally investigated. For instance, with the half-cylindrical reflector, the maximal diameter was 5.0 mm for a hole diameter of 6.0 mm, and droplets were levitatable up to a hole diameter of 12 mm (∼λ).

  13. Molecular Epidemiology of a Pseudomonas aeruginosa Hospital Outbreak Driven by a Contaminated Disinfectant-Soap Dispenser

    Science.gov (United States)

    Lanini, Simone; D'Arezzo, Silvia; Puro, Vincenzo; Martini, Lorena; Imperi, Francesco; Piselli, Pierluca; Montanaro, Marco; Paoletti, Simonetta; Visca, Paolo; Ippolito, Giuseppe

    2011-01-01

    Background and Objective Pseudomonas aeruginosa infection represents a main cause of morbidity and mortality among immunocompromised patients. This study describes a fatal epidemic of P. aeruginosa that occurred in a hematology unit in Italy. Methods Retrospective cohort study, prospective surveillance, auditing, extensive testing on healthcare workers and environmental investigation were performed to define the dynamics and potential causes of transmission. RAPD, macrorestriction analyses and sequence typing were used to define relationships between P. aeruginosa isolates. Results Eighteen cases of infection were identified in the different phases of the investigation. Of these, five constitute a significant molecular cluster of infection. A P. aeruginosa strain with the same genetic fingerprint and sequence type (ST175) as clinical isolates strain was also isolated from a heavily contaminated triclosan soap dispenser. Discussion and Conclusions Our results are consistent with the hypothesis that patients became indirectly infected, e.g., during central venous catheter handling through contaminated items, and that the triclosan soap dispenser acted as a common continuous source of P. aeruginosa infection. Since P. aeruginosa is intrinsically unsusceptible to triclosan, the use of triclosan-based disinfectant formulations should be avoided in those healthcare settings hosting patients at high risk of P. aeruginosa infection. PMID:21359222

  14. Prescription Drug Monitoring Programs and Pharmacist Orientation Toward Dispensing Controlled Substances.

    Science.gov (United States)

    Fendrich, Michael; Bryan, Janelle K; Hooyer, Katinka

    2018-01-03

    We sought to understand how pharmacists viewed and used a newly implemented prescription drug monitoring program (PDMP). We also sought to understand pharmacist orientation toward dispensing of controlled substances and the people who obtain them. We conducted three mini focus groups. The focus group findings were used to inform the design of a structured survey. We emailed a survey to 160 pharmacists who were employed in one statewide community chain store; we obtained 48 survey responses. Focus groups findings suggested that, in relation to the dispensing of scheduled prescription medication, pharmacists were either "healthcare" oriented, "law-enforcement" oriented, or an orientation that combined these two perspectives. Surveys suggested that pharmacists found PDMPs easy to use and that they used them frequently - often to contact physicians directly. Surveys suggested that pharmacists were typically either "healthcare" oriented or "mixed" (combined perspectives). Pharmacist orientation was associated with the frequency with which they counseled patients about medication risk and the frequency with which they used the PDMP as the basis for contacting prescribers. Ongoing tracking of pharmacists' use of PDMPs is important both at the implementation stage and as PDMPs develop over time. The orientation construct developed here is useful in understanding pharmacist behavior and attitudes towards patients potentially at risk for misuse of controlled substance medications. Further research on this construct could shed light on barriers and incentives for pharmacist PDMP participation and use and provide guidance for pharmacist training, ultimately enhancing patient care.

  15. Vital and dispensable roles of Plasmodium multidrug resistance transporters during blood- and mosquito-stage development.

    Science.gov (United States)

    Rijpma, Sanna R; van der Velden, Maarten; Annoura, Takeshi; Matz, Joachim M; Kenthirapalan, Sanketha; Kooij, Taco W A; Matuschewski, Kai; van Gemert, Geert-Jan; van de Vegte-Bolmer, Marga; Siebelink-Stoter, Rianne; Graumans, Wouter; Ramesar, Jai; Klop, Onny; Russel, Frans G M; Sauerwein, Robert W; Janse, Chris J; Franke-Fayard, Blandine M; Koenderink, Jan B

    2016-07-01

    Multidrug resistance (MDR) proteins belong to the B subfamily of the ATP Binding Cassette (ABC) transporters, which export a wide range of compounds including pharmaceuticals. In this study, we used reverse genetics to study the role of all seven Plasmodium MDR proteins during the life cycle of malaria parasites. Four P. berghei genes (encoding MDR1, 4, 6 and 7) were refractory to deletion, indicating a vital role during blood stage multiplication and validating them as potential targets for antimalarial drugs. Mutants lacking expression of MDR2, MDR3 and MDR5 were generated in both P. berghei and P. falciparum, indicating a dispensable role for blood stage development. Whereas P. berghei mutants lacking MDR3 and MDR5 had a reduced blood stage multiplication in vivo, blood stage growth of P. falciparum mutants in vitro was not significantly different. Oocyst maturation and sporozoite formation in Plasmodium mutants lacking MDR2 or MDR5 was reduced. Sporozoites of these P. berghei mutants were capable of infecting mice and life cycle completion, indicating the absence of vital roles during liver stage development. Our results demonstrate vital and dispensable roles of MDR proteins during blood stages and an important function in sporogony for MDR2 and MDR5 in both Plasmodium species. © 2016 John Wiley & Sons Ltd.

  16. Barriers, motivators and enablers for dispensing multifocal contact lenses in Mumbai, India.

    Science.gov (United States)

    Thite, Nilesh; Shah, Ukti; Mehta, Jasmin; Jurkus, Janice

    2015-01-01

    To understand the potential barriers, motivators and enablers in dispensing multifocal contact lenses (MFCL). Two focus group discussions were conducted to design questionnaires regarding the prescribing habits for multifocal contact lenses (MFCL). Questions on potential barriers and motivators were included. The questionnaires were distributed among 133 eye care practitioners across Mumbai, India. Practitioners fitting one or less patient per month with MFCL completed the survey describing potential barriers, while those who prescribed more MFCL's per month completed the survey describing enablers and motivators. Responses from 102 practitioners were received. Most common potential barriers in prescribing MFCL were increased chair time (75%), lack of readily available trials (69%) and limitation in power range (63%). Lack of awareness among patients (90%) was the most common barrier from patients' outlook. Professional satisfaction (88%) and better business proposition (82%) were observed as main motivators while availability of the trials (84%) and correct patient selection (82%) were the major enablers. Graduate Optometrists felt dispensing MFCL did not offer a good business proposition (p=0.02). Experienced practitioners were observed to be least motivated (p=0.01) and believed that their patients found these lenses expensive (p=0.02). To enhance the MFCL practice, barriers like lack of awareness and limitations in power range must be addressed. Trial lens availability may motivate practitioners to prescribe MFCL. Further probing is required to understand lack of motivation among experienced practitioners. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  17. Kas netilpo tarp politikos ir diplomatijos?

    OpenAIRE

    Streikus, Arūnas

    2008-01-01

    The review analyzes A. Kasparavičius’s monograph “Tarp Politikos ir Diplomatijos: Šventasis Sostas ir Lietuvos Respublika” (Vilnius, 2008). The historiographic value of the study is undisputed. A. Kasperavičius had an opportunity to use a broad spectrum of sources, among which two sets of archive documents stand out: the funds of the archives of Ministry of Foreign Affairs of Lithuania and the Lithuanian Embassy under the Holy See in Rome. A. Kasparavičius managed to avoid the arid scientific...

  18. Elecciones Legislativas en Irán

    Directory of Open Access Journals (Sweden)

    José Antonio Sainz de la Peña

    2012-05-01

    Full Text Available Las elecciones legislativas en Irán, una vez eliminados los reformistas se han celebrado en un clima de rivalidad. Las elecciones tenían que dejar claro quién mandaba en Irán, si los clérigos y el Guía el ayatolá Seyed Ali Jamenei o, el Presidente de la República, el laico Mahmud Ahmadineyad, apoyado en el Cuerpo de Guardias Revolucionarios. La realidad ha sido que las facciones conservadoras encabezadas por el Frente Unido Principalista, apoyados por el Guía Supremo, han obtenido el triunfo.

  19. Prototype of a Questionnaire and Quiz System for Supporting Increase of Health Awareness During Wait Time in Dispensing Pharmacy

    Science.gov (United States)

    Toda, Takeshi; Chen, Poa-Min; Ozaki, Shinya; Ideguchi, Naoko; Miyaki, Tomoko; Nanbu, Keiko; Ikeda, Keiko

    For quit-smoking clinic and its campaign, there was a need for pharmacists to investigate pediatric patient's parent consciousness to tobacco harm utilizing wait time in a pediatric dispensing pharmacy. In this research, we developed the questionnaire and quiz total system using the tablet for user interface, in which people can easily answer the questionnaire/quiz and quickly see the total results on the spot in order to enhance their consciousness to the tobacco harm. The system also provides their tobacco dependence level based on the questionnaire results and some advice for their health and dietary habits due to the tobacco dependence level. From a field trial with one hundred four examinees in the pediatric dispensing pharmacy, the user interface was useful compared to conventional questionnaire form. The system could enhance their consciousness to tobacco harm and make their beneficial use of waiting time in dispensing pharmacy. Some interesting suggestions for improvement and new services were also obtained.

  20. Treatment practices of households and antibiotic dispensing in medicine outlets in developing countries: The case of Ghana

    DEFF Research Database (Denmark)

    Tersbøl, Britt Pinkowski

    2018-01-01

    in households and the antibiotic dispensing practices of medicine sales outlets in Eastern region, Ghana. Method: Twice-weekly illness recall visits were made to 12 households in three rural communities over eight consecutive weeks. Detailed fieldnotes were taken and analysed using a thematic approach....... Quantitative counts of health events and treatment were also conducted. Dispensing practices were systematically observed and documented in three rural and three urban medicine outlets for analysis. Result: Fever, abdominal, and respiratory symptoms were the most common causes of ill-health in the 12...... an integral part of healthcare in the study settings and the qualitative data provides a contextual understanding of over-the-counter antibiotic acquisition and use. Inappropriate antibiotic use is apparent in the study settings. Stricter regulation of the pharmaceutical sector, training of dispensers...

  1. What do Australian consumers, pharmacists and prescribers think about documenting indications on prescriptions and dispensed medicines labels?: A qualitative study.

    Science.gov (United States)

    Garada, Mona; McLachlan, Andrew J; Schiff, Gordon D; Lehnbom, Elin C

    2017-11-15

    Documenting the indication on prescriptions and dispensed medicines labels is not standard practice in Australia. However, previous studies that have focused on the content and design of dispensed medicines labels, have suggested including the indication as a safety measure. The aim of this study was to investigate the perspectives of Australian consumers, pharmacists and prescribers on documenting the indication on prescriptions and dispensed medicines labels. Semi-structured interviews were conducted and mock-up of dispensed medicines labels were designed for participants. Consumers (n = 19) and pharmacists (n = 7) were recruited by convenience sample at community pharmacies in Sydney (Australia) and prescribers (n = 8), including two medical students, were recruited through snowballing. Thirty-four participants were interviewed. Most participants agreed that documenting the indication would be beneficial especially for patients who are forgetful or take multiple medications. Participants also believed it would improve consumers' medication understanding and adherence. Prescribers and pharmacists believed it could help reduce prescribing and dispensing errors by matching the drug/dosage to the correct indication. Prescribers refrained from documenting the indication to protect patients' privacy; however, most patients did not consider documenting the indication as a breach of privacy. Prescribers raised concerns about the extra time to include indications on prescriptions and best language to document indications, using plain language as opposed to medical terminology. All interviewed stakeholders identified numerous benefits of documenting the indication on prescriptions and dispensed medicines labels. Whether these potential benefits can be realized remains unknown and addressing prescribers' concern regarding the time involved in documenting the indication on prescriptions remains a challenge for vendors of electronic medication management systems.

  2. What do Australian consumers, pharmacists and prescribers think about documenting indications on prescriptions and dispensed medicines labels?: A qualitative study

    Directory of Open Access Journals (Sweden)

    Mona Garada

    2017-11-01

    Full Text Available Abstract Background Documenting the indication on prescriptions and dispensed medicines labels is not standard practice in Australia. However, previous studies that have focused on the content and design of dispensed medicines labels, have suggested including the indication as a safety measure. The aim of this study was to investigate the perspectives of Australian consumers, pharmacists and prescribers on documenting the indication on prescriptions and dispensed medicines labels. Methods Semi-structured interviews were conducted and mock-up of dispensed medicines labels were designed for participants. Consumers (n = 19 and pharmacists (n = 7 were recruited by convenience sample at community pharmacies in Sydney (Australia and prescribers (n = 8, including two medical students, were recruited through snowballing. Results Thirty-four participants were interviewed. Most participants agreed that documenting the indication would be beneficial especially for patients who are forgetful or take multiple medications. Participants also believed it would improve consumers’ medication understanding and adherence. Prescribers and pharmacists believed it could help reduce prescribing and dispensing errors by matching the drug/dosage to the correct indication. Prescribers refrained from documenting the indication to protect patients’ privacy; however, most patients did not consider documenting the indication as a breach of privacy. Prescribers raised concerns about the extra time to include indications on prescriptions and best language to document indications, using plain language as opposed to medical terminology. Conclusions All interviewed stakeholders identified numerous benefits of documenting the indication on prescriptions and dispensed medicines labels. Whether these potential benefits can be realized remains unknown and addressing prescribers’ concern regarding the time involved in documenting the indication on prescriptions

  3. Encapsulated thermopile detector array for IR microspectrometer

    NARCIS (Netherlands)

    Wu, H.; Emadi, A.; De Graaf, G.; Wolffenbuttel, R.F.

    2010-01-01

    The miniaturized IR spectrometer discussed in this paper is comprised of: slit, planar imaging diffraction grating and Thermo-Electric (TE) detector array, which is fabricated using CMOS compatible MEMS technology. The resolving power is maximized by spacing the TE elements at an as narrow as

  4. TIJAH: Embracing IR Methods in XML Databases

    NARCIS (Netherlands)

    List, Johan; Mihajlovic, V.; Ramirez, Georgina; de Vries, A.P.; Hiemstra, Djoerd; Blok, H.E.

    2005-01-01

    This paper discusses our participation in INEX (the Initiative for the Evaluation of XML Retrieval) using the TIJAH XML-IR system. TIJAH's system design follows a `standard' layered database architecture, carefully separating the conceptual, logical and physical levels. At the conceptual level, we

  5. IR and OLAP in XML document warehouses

    DEFF Research Database (Denmark)

    Perez, Juan Manuel; Pedersen, Torben Bach; Berlanga, Rafael

    2005-01-01

    In this paper we propose to combine IR and OLAP (On-Line Analytical Processing) technologies to exploit a warehouse of text-rich XML documents. In the system we plan to develop, a multidimensional implementation of a relevance modeling document model will be used for interactively querying...

  6. Isolated Gramicidin Peptides Probed by IR Spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Rijs, A. M.; Kabeláč, Martin; Abo-Riziq, A.; Hobza, Pavel; de Vries, M. S.

    2011-01-01

    Roč. 12, č. 10 (2011), s. 1816-1821 ISSN 1439-4235 R&D Projects: GA MŠk LC512; GA AV ČR IAA400550808 Institutional research plan: CEZ:AV0Z40550506 Keywords : density functional calculations * gramicidin * IR spectroscopy * protein folding Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.412, year: 2011

  7. Airborne pipeline leak detection: UV or IR?

    Science.gov (United States)

    Babin, François; Gravel, Jean-François; Allard, Martin

    2016-05-01

    This paper presents a study of different approaches to the measurement of the above ground vapor plume created by the spill caused by a small 0.1 l/min (or less) leak in an underground liquid petroleum pipeline. The scenarios are those for the measurement from an airborne platform. The usual approach is that of IR absorption, but in the case of liquid petroleum products, there are drawbacks that will be discussed, especially when using alkanes to detect a leak. The optical measurements studied include UV enhanced Raman lidar, UV fluorescence lidar and IR absorption path integrated lidars. The breadboards used for testing the different approaches will be described along with the set-ups for leak simulation. Although IR absorption would intuitively be the most sensitive, it is shown that UV-Raman could be an alternative. When using the very broad alkane signature in the IR, the varying ground spectral reflectance are a problem. It is also determined that integrated path measurements are preferred, the UV enhanced Raman measurements showing that the vapor plume stays very close to the ground.

  8. Near IR spectra of symbiotic stars

    International Nuclear Information System (INIS)

    Andrillat, Y.

    1982-01-01

    The author reports on recent observations from the near IR spectra of symbiotic stars. The helium and oxygen lines useful for the construction of theoretical models are identified. Observations for cool stars and novae (nebular phase) are outlined and the spectra of specific symbiotic stars between lambdalambda 8000-11000 are presented and discussed. (Auth./C.F.)

  9. Methanol decomposition and oxidation on Ir(111)

    NARCIS (Netherlands)

    Weststrate, C.J.; Ludwig, W.; Bakker, J.W.; Gluhoi, A.C.; Nieuwenhuys, B.E.

    2007-01-01

    The adsorption, decompn., and oxidn. of methanol (CH3OH) has been studied on Ir(111) using temp.-programmed desorption and high-energy resoln. fast XPS. Mol. methanol desorption from a methanol-satd. surface at low temp. shows three desorption peaks, around 150 K (alpha ), around 170 K (beta 1), and

  10. Column Stores as an IR Prototyping Tool

    NARCIS (Netherlands)

    H.F. Mühleisen (Hannes); T. Samar (Thaer); J.J.P. Lin (Jimmy); A.P. de Vries (Arjen)

    2014-01-01

    textabstract. We make the suggestion that instead of implementing custom index structures and query evaluation algorithms, IR researchers should simply store document representations in a column-oriented relational database and write ranking models using SQL. For rapid prototyping, this is

  11. The TApIR experiment. IR absorption spectra of liquid hydrogen isotopologues

    International Nuclear Information System (INIS)

    Groessle, Robin

    2015-01-01

    The scope of the thesis is the infrared absorption spectroscopy of liquid hydrogen isotopologues with the tritium absorption infrared spectroscopy (TApIR) experiment at the tritium laboratory Karlsruhe (TLK). The calibration process from the sample preparation to the reference measurements are described. A further issue is the classical evaluation of FTIR absorption spectra and the extension using the rolling circle filter (RCF) including the effects on statistical and systematical errors. The impact of thermal and nuclear spin temperature on the IR absorption spectra is discussed. An empirical based modeling for the IR absorption spectra of liquid hydrogen isotopologues is performed.

  12. Care relationships at stake? Home healthcare professionals' experiences with digital medicine dispensers - a qualitative study.

    Science.gov (United States)

    Nakrem, Sigrid; Solbjør, Marit; Pettersen, Ida Nilstad; Kleiven, Hanne Hestvik

    2018-01-15

    Although digital technologies can mitigate the burdens of home healthcare services caused by an ageing population that lives at home longer with complex health problems, research on the impacts and consequences of digitalised remote communication between patients and caregivers is lacking. The present study explores how home healthcare professionals had experienced the introduction of digital medicine dispensers and their influence on patient-caregiver relationships. The multi-case study comprised semi-structured interviews with 21 healthcare professionals whose home healthcare service involved using the digital medicine dispensers. The constant comparative method was used for data analyses. Altogether, interviewed healthcare professionals reported three main technology-related impacts upon their patient-caregiver relationships. First, national and local pressure to increase efficiency had troubled their relationships with patients who suspected that municipalities have sought to lower costs by reducing and digitalising services. Participants reported having to consider such worries when introducing technologies into their services. Second, participants reported a shift towards empowering patients. Digital technology can empower patients who value their independence, whereas safety is more important for other patients. Healthcare professionals needed to ensure that replacing care tasks with technology implies safe and improved care. Third, the safety and quality of digital healthcare services continues to depend upon surveillance and control mechanisms that compensate for less face-to-face monitoring. Participants did not consider the possibility that surveillance exposes information about patients' everyday lives to be problematic, but to constitute opportunities for adjusting services to meet patients' needs. Technologies such as digital medicine dispensers can improve the efficiency of healthcare services and enhance patients' independence when introduced in a

  13. [Monitoring medication errors in personalised dispensing using the Sentinel Surveillance System method].

    Science.gov (United States)

    Pérez-Cebrián, M; Font-Noguera, I; Doménech-Moral, L; Bosó-Ribelles, V; Romero-Boyero, P; Poveda-Andrés, J L

    2011-01-01

    To assess the efficacy of a new quality control strategy based on daily randomised sampling and monitoring a Sentinel Surveillance System (SSS) medication cart, in order to identify medication errors and their origin at different levels of the process. Prospective quality control study with one year follow-up. A SSS medication cart was randomly selected once a week and double-checked before dispensing medication. Medication errors were recorded before it was taken to the relevant hospital ward. Information concerning complaints after receiving medication and 24-hour monitoring were also noted. Type and origin error data were assessed by a Unit Dose Quality Control Group, which proposed relevant improvement measures. Thirty-four SSS carts were assessed, including 5130 medication lines and 9952 dispensed doses, corresponding to 753 patients. Ninety erroneous lines (1.8%) and 142 mistaken doses (1.4%) were identified at the Pharmacy Department. The most frequent error was dose duplication (38%) and its main cause inappropriate management and forgetfulness (69%). Fifty medication complaints (6.6% of patients) were mainly due to new treatment at admission (52%), and 41 (0.8% of all medication lines), did not completely match the prescription (0.6% lines) as recorded by the Pharmacy Department. Thirty-seven (4.9% of patients) medication complaints due to changes at admission and 32 matching errors (0.6% medication lines) were recorded. The main cause also was inappropriate management and forgetfulness (24%). The simultaneous recording of incidences due to complaints and new medication coincided in 33.3%. In addition, 433 (4.3%) of dispensed doses were returned to the Pharmacy Department. After the Unit Dose Quality Control Group conducted their feedback analysis, 64 improvement measures for Pharmacy Department nurses, 37 for pharmacists, and 24 for the hospital ward were introduced. The SSS programme has proven to be useful as a quality control strategy to identify Unit

  14. What proportion of prescription items dispensed in community pharmacies are eligible for the New Medicine Service?

    Science.gov (United States)

    Wells, Katharine M; Boyd, Matthew J; Thornley, Tracey; Boardman, Helen F

    2014-03-07

    The payment structure for the New Medicine Service (NMS) in England is based on the assumption that 0.5% of prescription items dispensed in community pharmacies are eligible for the service. This assumption is based on a theoretical calculation. This study aimed to find out the actual proportion of prescription items eligible for the NMS dispensed in community pharmacies in order to compare this with the theoretical assumption. The study also aimed to investigate whether the proportion of prescription items eligible for the NMS is affected by pharmacies' proximity to GP practices. The study collected data from eight pharmacies in Nottingham belonging to the same large chain of pharmacies. Pharmacies were grouped by distance from the nearest GP practice and sampled to reflect the distribution by distance of all pharmacies in Nottingham. Data on one thousand consecutive prescription items were collected from each pharmacy and the number of NMS eligible items recorded. All NHS prescriptions were included in the sample. Data were analysed and proportions calculated with 95% confidence intervals used to compare the study results against the theoretical figure of 0.5% of prescription items being eligible for the NMS. A total of 8005 prescription items were collected (a minimum of 1000 items per pharmacy) of which 17 items were eligible to receive the service. The study found that 0.25% (95% confidence intervals: 0.14% to 0.36%) of prescription items were eligible for the NMS which differs significantly from the theoretical assumption of 0.5%. The opportunity rate for the service was lower, 0.21% (95% confidence intervals: 0.10% to 0.32%) of items, as some items eligible for the NMS did not translate into opportunities to offer the service. Of all the prescription items collected in the pharmacies, 28% were collected by patient representatives. The results of this study show that the proportion of items eligible for the NMS dispensed in community pharmacies is lower than

  15. Refinement of Foam Backfill Technology for Expedient Airfield Damage Repair; Phase 2: Development of Prototype Foam Dispensing Equipment and Improved Tactics, Techniques and Procedures

    Science.gov (United States)

    2017-12-01

    ER D C TR -1 7- 14 U.S. Air Force Rapid Airfield Damage Repair Modernization Program Refinement of Foam Backfill Technology for...Backfill Technology for Expedient Airfield Damage Repair Phase II: Development of Prototype Foam Dispensing Equipment and Improved Tactics...procedures (TTPs) for rapid airfield damage repair (RADR) using foam backfill technology . Three different prototype foam dispensing systems were

  16. Randomized crossover study evaluating the effect of a hand sanitizer dispenser on the frequency of hand hygiene among anesthesiology staff in the operating room.

    Science.gov (United States)

    Munoz-Price, L Silvia; Patel, Zalak; Banks, Shawn; Arheart, Kristopher; Eber, Scott; Lubarsky, David A; Birnbach, David J

    2014-06-01

    Forty anesthesia providers were evaluated with and without hand sanitizer dispensers present on the anesthesia machine. Having a dispenser increased the frequency of hand hygiene only from 0.5 to 0.8 events per hour (P = .01). Other concomitant interventions are needed to further increase hand hygiene frequency among anesthesia providers.

  17. Metal-Mesh Optical Filter Technology for Mid IR, Far IR, and Submillimeter, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovative, high transmission band-pass filter technology proposed here is an improvement in multilayer metal-mesh filter design and manufacture for the far IR...

  18. IR-IR Conformation Specific Spectroscopy of Na+(Glucose) Adducts

    Science.gov (United States)

    Voss, Jonathan M.; Kregel, Steven J.; Fischer, Kaitlyn C.; Garand, Etienne

    2018-01-01

    We report an IR-IR double resonance study of the structural landscape present in the Na+(glucose) complex. Our experimental approach involves minimal modifications to a typical IR predissociation setup, and can be carried out via ion-dip or isomer-burning methods, providing additional flexibility to suit different experimental needs. In the current study, the single-laser IR predissociation spectrum of Na+(glucose), which clearly indicates contributions from multiple structures, was experimentally disentangled to reveal the presence of three α-conformers and five β-conformers. Comparisons with calculations show that these eight conformations correspond to the lowest energy gas-phase structures with distinctive Na+ coordination. [Figure not available: see fulltext.

  19. Centrioles initiate cilia assembly but are dispensable for maturation and maintenance in C. elegans.

    Science.gov (United States)

    Serwas, Daniel; Su, Tiffany Y; Roessler, Max; Wang, Shaohe; Dammermann, Alexander

    2017-06-05

    Cilia are cellular projections that assemble on centriole-derived basal bodies. While cilia assembly is absolutely dependent on centrioles, it is not known to what extent they contribute to downstream events. The nematode C. elegans provides a unique opportunity to address this question, as centrioles do not persist at the base of mature cilia. Using fluorescence microscopy and electron tomography, we find that centrioles degenerate early during ciliogenesis. The transition zone and axoneme are not completely formed at this time, indicating that cilia maturation does not depend on intact centrioles. The hydrolethalus syndrome protein HYLS-1 is the only centriolar protein known to remain at the base of mature cilia and is required for intraflagellar transport trafficking. Surprisingly, targeted degradation of HYLS-1 after initiation of ciliogenesis does not affect ciliary structures. Taken together, our results indicate that while centrioles are essential to initiate cilia formation, they are dispensable for cilia maturation and maintenance. © 2017 Serwas et al.

  20. Method and apparatus for dispensing small quantities of mercury from evacuated and sealed glass capsules

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Pai, Robert Y.

    1985-01-01

    A technique for opening an evacuated and sealed glass capsule containing a material that is to be dispensed which has a relatively high vapor pressure such as mercury. The capsule is typically disposed in a discharge tube envelope. The technique involves the use of a first light source imaged along the capsule and a second light source imaged across the capsule substantially transversely to the imaging of the first light source. Means are provided for constraining a segment of the capsule along its length with the constraining means being positioned to correspond with the imaging of the second light source. These light sources are preferably incandescent projection lamps. The constraining means is preferably a multiple looped wire support.

  1. "This is not a drill": Activation of a student-led influenza vaccination point of dispensing.

    Science.gov (United States)

    Adams, Lavonne M; Canclini, Sharon; Tillman, Kelle

    2018-04-13

    To describe activation of a Point of dispensing (POD) in response to an influenza outbreak, highlighting the use of a student-led model. Faculty, staff, and students of Harris College of Nursing and Health Sciences, Texas Christian University (TCU), as well as those located in its primary building. In response to an August 2017 influenza outbreak, a vaccination clinic was conducted for a target population through POD activation. The larger campus community was served through provision of additional doses by the Texas Christian University Health Center and the annual October student-led vaccination clinic. Eleven additional cases were diagnosed after vaccinations began. One hundred percent of the targeted population was vaccinated (n = 824), with an additional 127 participants vaccinated (others working in the building where POD held also vaccinated). This was the first time POD activation had occurred on campus in response to an outbreak.

  2. Lipid Droplet Formation Is Dispensable for Endoplasmic Reticulum-associated Degradation*

    Science.gov (United States)

    Olzmann, James A.; Kopito, Ron R.

    2011-01-01

    Proteins that fail to fold or assemble in the endoplasmic reticulum (ER) are destroyed by cytoplasmic proteasomes through a process known as ER-associated degradation. Substrates of this pathway are initially sequestered within the ER lumen and must therefore be dislocated across the ER membrane to be degraded. It has been proposed that generation of bicellar structures during lipid droplet formation may provide an “escape hatch” through which misfolded proteins, toxins, and viruses can exit the ER. We have directly tested this hypothesis by exploiting yeast strains defective in lipid droplet formation. Our data demonstrate that lipid droplet formation is dispensable for the dislocation of a plant toxin and the degradation of both soluble and integral membrane glycoproteins. PMID:21693705

  3. Solvent removal and spore inactivation directly in dispensing vials with supercritical carbon dioxide and sterilant.

    Science.gov (United States)

    Howell, Jahna; Niu, Fengui; McCabe, Shannon E; Zhou, Wei; Decedue, Charles J

    2012-06-01

    A process is described using supercritical carbon dioxide to extract organic solvents from drug solutions contained in 30-mL serum vials. We report drying times of less than 1 h with quantitative recovery of sterile drug. A six-log reduction of three spore types used as biological indicators is achieved with direct addition of peracetic acid to a final concentration of approximately 5 mM (~0.04 %) to the drug solution in the vial. Analysis of two drugs, acetaminophen and paclitaxel, indicated no drug degradation as a result of the treatment. Furthermore, analysis of the processed drug substance showed that no residual peracetic acid could be detected in the final product. We have demonstrated an effective means to simultaneously dry and sterilize active pharmaceutical ingredients from organic solvents directly in a dispensing container.

  4. Acetyl CoA Carboxylase 2 Is Dispensable for CD8+ T Cell Responses.

    Directory of Open Access Journals (Sweden)

    Jang Eun Lee

    Full Text Available Differentiation of T cells is closely associated with dynamic changes in nutrient and energy metabolism. However, the extent to which specific metabolic pathways and molecular components are determinative of CD8+ T cell fate remains unclear. It has been previously established in various tissues that acetyl CoA carboxylase 2 (ACC2 regulates fatty acid oxidation (FAO by inhibiting carnitine palmitoyltransferase 1 (CPT1, a rate-limiting enzyme of FAO in mitochondria. Here, we explore the cell-intrinsic role of ACC2 in T cell immunity in response to infections. We report here that ACC2 deficiency results in a marginal increase of cellular FAO in CD8+ T cells, but does not appear to influence antigen-specific effector and memory CD8+ T cell responses during infection with listeria or lymphocytic choriomeningitis virus. These results suggest that ACC2 is dispensable for CD8+ T cell responses.

  5. Catch-slip bonds can be dispensable for motor force regulation during skeletal muscle contraction

    Science.gov (United States)

    Dong, Chenling; Chen, Bin

    2015-07-01

    It is intriguing how multiple molecular motors can perform coordinated and synchronous functions, which is essential in various cellular processes. Recent studies on skeletal muscle might have shed light on this issue, where rather precise motor force regulation was partly attributed to the specific stochastic features of a single attached myosin motor. Though attached motors can randomly detach from actin filaments either through an adenosine triphosphate (ATP) hydrolysis cycle or through "catch-slip bond" breaking, their respective contribution in motor force regulation has not been clarified. Here, through simulating a mechanical model of sarcomere with a coupled Monte Carlo method and finite element method, we find that the stochastic features of an ATP hydrolysis cycle can be sufficient while those of catch-slip bonds can be dispensable for motor force regulation.

  6. Rac1 in muscle is dispensable for improved insulin action after exercise in mice

    DEFF Research Database (Denmark)

    Sylow, Lykke; Møller, Lisbeth Liliendal Valbjørn; D'Hulst, Gommaar

    2016-01-01

    sensitivity in inducible muscle-specific Rac1 knockout (mKO) and wildtype littermate (WT) mice. Prior exercise enhanced whole body insulin sensitivity by 40% in WT mice and rescued the insulin intolerance in Rac1 mKO mice by improving whole body insulin sensitivity by 230%. In agreement, prior exercise...... significantly improved insulin sensitivity by 20% in WT and by 40% in Rac1 mKO soleus muscles. These findings suggest that muscle Rac1 is dispensable for the insulin sensitizing effect of exercise. Moreover, insulin resistance in Rac1 mKO mice can be completely normalized by prior exercise explaining why......Exercise has a potent insulin-sensitivity enhancing effect on skeletal muscle but the intracellular mechanisms that mediate this effect are not well understood. In muscle, Rac1 regulates both insulin- and contraction-stimulated glucose transport and is dysregulated in insulin resistant muscle...

  7. Investigation of Influence of Surface Nanoparticle on Emission Properties of Scandia-Doped Dispenser Cathodes

    Science.gov (United States)

    Zhang, Xizhu; Wang, Jinshu; Wang, Yiman; Liu, Wei; Zhou, Meiling; Gao, Zhiyuan

    2013-06-01

    The microstructure of a fully activated scandia doped dispenser (SDD) cathode has been studied by scanning electron microscope (SEM). The observation results display that nanoparticles appear at the growth steps and the surface of tungsten grains of the fully activated SDD cathode. To study the influence of the nanoparticles on the emission, the local electric field strengths around the nanoparticles have been calculated by Maxwell 2D code and Comsol. The calculation results show that the local electric field strengths are enhanced by 1.1 to 3.8 times to average value based on different model conditions. The highest field strength is about 1.54 × 105 V/cm at an average field strength of 40 KV/cm, which is related to a space-charge limited (SCL) current density of 100 A/cm2 in the experimental configuration. This implies the field strength is not high enough to cause field emission.

  8. A network collaboration implementing technology to improve medication dispensing and administration in critical access hospitals.

    Science.gov (United States)

    Wakefield, Douglas S; Ward, Marcia M; Loes, Jean L; O'Brien, John

    2010-01-01

    We report how seven independent critical access hospitals collaborated with a rural referral hospital to standardize workflow policies and procedures while jointly implementing the same health information technologies (HITs) to enhance medication care processes. The study hospitals implemented the same electronic health record, computerized provider order entry, pharmacy information systems, automated dispensing cabinets (ADC), and barcode medication administration systems. We conducted interviews and examined project documents to explore factors underlying the successful implementation of ADC and barcode medication administration across the network hospitals. These included a shared culture of collaboration; strategic sequencing of HIT component implementation; interface among HIT components; strategic placement of ADCs; disciplined use and sharing of workflow analyses linked with HIT applications; planning for workflow efficiencies; acquisition of adequate supply of HIT-related devices; and establishing metrics to monitor HIT use and outcomes.

  9. Fast switching of alkali atom dispensers using laser-induced heating

    International Nuclear Information System (INIS)

    Griffin, P.F.; Weatherill, K.J.; Adams, C.S.

    2005-01-01

    We show that by using an intense laser source to locally heat an alkali atom dispenser, one can generate a high flux of atoms followed by fast recovery (<100 ms) of the background pressure when the laser is extinguished. For repeated heating pulses a switch-on time for the atomic flux of 200 ms is readily attainable. This technique is suited to ultracold atom experiments using simple ultrahigh vacuum (UHV) chambers. Laser-induced heating provides a fast repetition of the experimental cycle, which, combined with low atom loss due to background gas collisions, is particularly useful for experiments involving far-off resonance optical traps, where sufficient laser power (0.5-4 W) is readily available

  10. Hydrogen Station Compression, Storage, and Dispensing Technical Status and Costs: Systems Integration

    Energy Technology Data Exchange (ETDEWEB)

    Parks, G.; Boyd, R.; Cornish, J.; Remick, R.

    2014-05-01

    At the request of the U.S. Department of Energy Fuel Cell Technologies Office (FCTO), the National Renewable Energy Laboratory commissioned an independent review of hydrogen compression, storage, and dispensing (CSD) for pipeline delivery of hydrogen and forecourt hydrogen production. The panel was asked to address the (1) cost calculation methodology, (2) current cost/technical status, (3) feasibility of achieving the FCTO's 2020 CSD levelized cost targets, and to (4) suggest research areas that will help the FCTO reach its targets. As the panel neared the completion of these tasks, it was also asked to evaluate CSD costs for the delivery of hydrogen by high-pressure tube trailer. This report details these findings.

  11. Printed droplet microfluidics for on demand dispensing of picoliter droplets and cells.

    Science.gov (United States)

    Cole, Russell H; Tang, Shi-Yang; Siltanen, Christian A; Shahi, Payam; Zhang, Jesse Q; Poust, Sean; Gartner, Zev J; Abate, Adam R

    2017-08-15

    Although the elementary unit of biology is the cell, high-throughput methods for the microscale manipulation of cells and reagents are limited. The existing options either are slow, lack single-cell specificity, or use fluid volumes out of scale with those of cells. Here we present printed droplet microfluidics, a technology to dispense picoliter droplets and cells with deterministic control. The core technology is a fluorescence-activated droplet sorter coupled to a specialized substrate that together act as a picoliter droplet and single-cell printer, enabling high-throughput generation of intricate arrays of droplets, cells, and microparticles. Printed droplet microfluidics provides a programmable and robust technology to construct arrays of defined cell and reagent combinations and to integrate multiple measurement modalities together in a single assay.

  12. Elongation factor P is dispensable in Escherichia coli and Pseudomonas aeruginosa.

    Science.gov (United States)

    Balibar, Carl J; Iwanowicz, Dorothy; Dean, Charles R

    2013-09-01

    Elongation factor P (EF-P) is a highly conserved ribosomal initiation factor responsible for stimulating formation of the first peptide bond. Its essentiality has been debated and may differ depending on the organism. Here, we demonstrate that EF-P is dispensable in Escherichia coli and Pseudomonas aeruginosa under laboratory growth conditions. Although knockouts are viable, growth rates are diminished compared with wild-type strains. Despite this cost in fitness, these mutants are not more susceptible to a wide range of antibiotics; including ribosome targeting antibiotics, such as lincomycin, chloramphenicol, and streptomycin, which have been shown previously to disrupt EF-P function in vitro. In Pseudomonas, knockout of efp leads to an upregulation of mexX, a phenotype previously observed with other genetic lesions affecting ribosome function and that can be induced by the treatment with antibiotics affecting protein synthesis.

  13. ASCIZ/ATMIN is dispensable for ATM signaling in response to replication stress.

    Science.gov (United States)

    Liu, Rui; King, Ashleigh; Hoch, Nicolas C; Chang, Catherine; Kelly, Gemma L; Deans, Andrew J; Heierhorst, Jörg

    2017-09-01

    The ATM kinase plays critical roles in the response to DNA double-strand breaks, and can also be activated by prolonged DNA replication blocks. It has recently been proposed that replication stress-dependent ATM activation is mediated by ASCIZ (also known as ATMIN, ZNF822), an essential developmental transcription factor. In contrast, we show here that ATM activation, and phosphorylation of its substrates KAP1, p53 and H2AX in response to the replication blocking agent aphidicolin was unaffected in both immortalized and primary ASCIZ/ATMIN-deficient murine embryonic fibroblasts compared to control cells. Similar results were also obtained in human ASCIZ/ATMIN-deleted lymphoma cells. The results demonstrate that ASCIZ/ATMIN is dispensable for ATM activation, and contradict the previously reported dependence of ATM on ASCIZ/ATMIN. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Studies on the pressed yttrium oxide-tungsten matrix as a possible dispenser cathode material

    International Nuclear Information System (INIS)

    Yang, Fan; Wang, Jinshu; Liu, Wei; Liu, Xiang; Zhou, Meiling

    2015-01-01

    Yttrium oxide was chosen as the secondary emission substance based on calculation results through first principle theory method. A new kind of pressed yttrium oxide-tungsten matrix dispenser cathodes are prepared by a sol–gel method combined with high temperature sintering in dry hydrogen atmosphere. The results show that the growth of the grains is hampered by the pinning effect of Y 2 O 3 distributing uniformly between the tungsten particles, resulting in the formation of small grain size. It is found that Y 2 O 3 improves the secondary electron emission property, i.e., the secondary emission yield increases with the increase of Y 2 O 3 content in the samples. The maximum secondary emission yield δ max of the cathode with 15% amount of Y 2 O 3 can reach 2.92. Furthermore, the cathode shows a certain thermionic emission performance. The zero field emission current density J 0 of 4.18A/cm 2 has reached at 1050 °C b for this kind of cathode after being activated at 1200 °C b , which are much higher than that of rare earth oxide doped molybdenum (REO-Mo) cathode reported in the previous work. - Highlights: • Yttrium oxide was chosen as the secondary emission substance based on first principle calculation result. • A new kind of cathode has been successfully obtained. • Pressed yttrium oxide-tungsten matrix dispenser cathode exhibits good emission properties. • The improvement of the cathode emission can be well explained by the surface analysis results presented in this work

  15. Studies on the pressed yttrium oxide-tungsten matrix as a possible dispenser cathode material

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Fan; Wang, Jinshu, E-mail: wangjsh@bjut.edu.cn; Liu, Wei; Liu, Xiang; Zhou, Meiling

    2015-01-15

    Yttrium oxide was chosen as the secondary emission substance based on calculation results through first principle theory method. A new kind of pressed yttrium oxide-tungsten matrix dispenser cathodes are prepared by a sol–gel method combined with high temperature sintering in dry hydrogen atmosphere. The results show that the growth of the grains is hampered by the pinning effect of Y{sub 2}O{sub 3} distributing uniformly between the tungsten particles, resulting in the formation of small grain size. It is found that Y{sub 2}O{sub 3} improves the secondary electron emission property, i.e., the secondary emission yield increases with the increase of Y{sub 2}O{sub 3} content in the samples. The maximum secondary emission yield δ{sub max} of the cathode with 15% amount of Y{sub 2}O{sub 3} can reach 2.92. Furthermore, the cathode shows a certain thermionic emission performance. The zero field emission current density J{sub 0} of 4.18A/cm{sup 2} has reached at 1050 °C{sub b} for this kind of cathode after being activated at 1200 °C{sub b}, which are much higher than that of rare earth oxide doped molybdenum (REO-Mo) cathode reported in the previous work. - Highlights: • Yttrium oxide was chosen as the secondary emission substance based on first principle calculation result. • A new kind of cathode has been successfully obtained. • Pressed yttrium oxide-tungsten matrix dispenser cathode exhibits good emission properties. • The improvement of the cathode emission can be well explained by the surface analysis results presented in this work.

  16. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  17. Impact assessment of an automated drug-dispensing system in a tertiary hospital

    Directory of Open Access Journals (Sweden)

    Débora de-Carvalho

    Full Text Available OBJECTIVE: To evaluate the costs and patient safety of a pilot implementation of an automated dispensing cabinet in a critical care unit of a private tertiary hospital in São Paulo/Brazil. METHODS: This study considered pre- (January-August 2013 and post- (October 2013-October 2014 intervention periods. We considered the time and cost of personnel, number of adverse events, audit adjustments to patient bills, and urgent requests and returns of medications to the central pharmacy. Costs were evaluated based on a 5-year analytical horizon and are reported in Brazilian Reals (R$ and US dollars (USD. RESULTS: The observed decrease in the mean number of events reported with regard to the automated drug-dispensing system between pre- and post-implementation periods was not significant. Importantly, the numbers are small, which limits the power of the mean comparative analysis between the two periods. A reduction in work time was observed among the nurses and administrative assistants, whereas pharmacist assistants showed an increased work load that resulted in an overall 6.5 hours of work saved/day and a reduction of R$ 33,598 (USD 14,444 during the first year. The initial investment (R$ 206,065; USD 88,592 would have been paid off in 5 years considering only personnel savings. Other findings included significant reductions of audit adjustments to patient hospital bills and urgent requests and returns of medications to the central pharmacy. CONCLUSIONS: Evidence of the positive impact of this technology on personnel time and costs and on other outcomes of interest is important for decision making by health managers.

  18. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  19. Suppression of superconductivity in Nb by IrMn in IrMn/Nb bilayers

    KAUST Repository

    Wu, B. L.

    2013-10-10

    Effect of antiferromagnet on superconductivity has been investigated in IrMn/Nb bilayers. Significant suppression of both transition temperature (Tc) and lower critical field (Hc1) of Nb is found in IrMn/Nb bilayers as compared to a single layer Nb of same thickness; the suppression effect is even stronger than that of a ferromagnet in NiFe/Nb bilayers. The addition of an insulating MgO layer at the IrMn-Nb interface nearly restores Tc to that of the single layer Nb, but Hc1 still remains suppressed. These results suggest that, in addition to proximity effect and magnetic impurity scattering, magnetostatic interaction also plays a role in suppressing superconductivity of Nb in IrMn/Nb bilayers. In addition to reduced Tc and Hc1, the IrMn layer also induces broadening in the transition temperature of Nb, which can be accounted for by a finite distribution of stray field from IrMn.

  20. Discrimination of Chinese Sauce liquor using FT-IR and two-dimensional correlation IR spectroscopy

    Science.gov (United States)

    Sun, Su-Qin; Li, Chang-Wen; Wei, Ji-Ping; Zhou, Qun; Noda, Isao

    2006-11-01

    We applied the three-step IR macro-fingerprint identification method to obtain the IR characteristic fingerprints of so-called Chinese Sauce liquor (Moutai liquor and Kinsly liquor) and a counterfeit Moutai. These fingerprints can be used for the identification and discrimination of similar liquor products. The comparison of their conventional IR spectra, as the first step of identification, shows that the primary difference in Sauce liquor is the intensity of characteristic peaks at 1592 and 1225 cm -1. The comparison of the second derivative IR spectra, as the second step of identification, shows that the characteristic absorption in 1400-1800 cm -1 is substantially different. The comparison of 2D-IR correlation spectra, as the third and final step of identification, can discriminate the liquors from another direction. Furthermore, the method was successfully applied to the discrimination of a counterfeit Moutai from the genuine Sauce liquor. The success of the three-step IR macro-fingerprint identification to provide a rapid and effective method for the identification of Chinese liquor suggests the potential extension of this technique to the identification and discrimination of other wine and spirits, as well.

  1. 21 CFR 369.3 - Warnings required on drugs exempted from prescription-dispensing requirements of section 503(b)(1...

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Warnings required on drugs exempted from prescription-dispensing requirements of section 503(b)(1)(C). 369.3 Section 369.3 Food and Drugs FOOD AND DRUG... subject to the labeling requirements prescribed in § 310.201(a) of this chapter. Although, for convenience...

  2. 75 FR 28651 - In the Matter of Certain Electronic Paper Towel Dispensing Devices and Components Thereof; Notice...

    Science.gov (United States)

    2010-05-21

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-718] In the Matter of Certain Electronic Paper Towel Dispensing Devices and Components Thereof; Notice of Investigation AGENCY: International Trade... that a complaint was filed with the U.S. International Trade Commission on April 19, 2010, under...

  3. 21 CFR 1300.04 - Definitions relating to the dispensing of controlled substances by means of the Internet.

    Science.gov (United States)

    2010-04-01

    ... controlled substances by means of the Internet. 1300.04 Section 1300.04 Food and Drugs DRUG ENFORCEMENT... substances by means of the Internet. (a) Any term not defined in this part or elsewhere in this chapter shall... evaluation of the patient. (c) The term deliver, distribute, or dispense by means of the Internet refers...

  4. Development of pixellated Ir-TESs

    Science.gov (United States)

    Zen, Nobuyuki; Takahashi, Hiroyuki; Kunieda, Yuichi; Damayanthi, Rathnayaka M. T.; Mori, Fumiakira; Fujita, Kaoru; Nakazawa, Masaharu; Fukuda, Daiji; Ohkubo, Masataka

    2006-04-01

    We have been developing Ir-based pixellated superconducting transition edge sensors (TESs). In the area of material or astronomical applications, the sensor with few eV energy resolution and over 1000 pixels imaging property is desired. In order to achieve this goal, we have been analyzing signals from pixellated TESs. In the case of a 20 pixel array of Ir-TESs, with 45 μm×45 μm pixel sizes, the incident X-ray signals have been classified into 16 groups. We have applied numerical signal analysis. On the one hand, the energy resolution of our pixellated TES is strongly degraded. However, using pulse shape analysis, we can dramatically improve the resolution. Thus, we consider that the pulse signal analysis will lead this device to be used as a practical photon incident position identifying TES.

  5. Development of pixellated Ir-TESs

    International Nuclear Information System (INIS)

    Zen, Nobuyuki; Takahashi, Hiroyuki; Kunieda, Yuichi; Dayanthi, Rathnayaka M.T.; Mori, Fumiakira; Fujita, Kaoru; Nakazawa, Masaharu; Fukuda, Daiji; Ohkubo, Masataka

    2006-01-01

    We have been developing Ir-based pixellated superconducting transition edge sensors (TESs). In the area of material or astronomical applications, the sensor with few eV energy resolution and over 1000 pixels imaging property is desired. In order to achieve this goal, we have been analyzing signals from pixellated TESs. In the case of a 20 pixel array of Ir-TESs, with 45 μmx45 μm pixel sizes, the incident X-ray signals have been classified into 16 groups. We have applied numerical signal analysis. On the one hand, the energy resolution of our pixellated TES is strongly degraded. However, using pulse shape analysis, we can dramatically improve the resolution. Thus, we consider that the pulse signal analysis will lead this device to be used as a practical photon incident position identifying TES

  6. Development of Ir/Au-TES microcalorimeter

    International Nuclear Information System (INIS)

    Kunieda, Yuichi; Fukuda, Daiji; Ohno, Masashi; Nakazawa, Masaharu; Takahashi, Hiroyuki; Ataka, Manabu; Ohkubo, Masataka; Hirayama, Fuminori

    2004-01-01

    We are developing X-ray microcalorimeters using transition edge sensors (TES) for high resolution x-ray spectroscopy. Microcalorimeters are thermal detectors which measure the energy of an incident x-ray photon using a TES thermometer operated at a sharp transition edge between normal and superconducting states. TES microcalorimeters can achieve faster response than conventional microcalorimeters by keeping the operating point of TES in the transition region through the use of strong negative electrothermal feedback (ETF). We developed a bilayer TES where a normal metal Au was deposited on a superconductor Ir in order to improve the thermal conductivity of the Ir-TES. We investigated resistance-temperature characteristics. As a result, it showed a very sharp transition within 1 mK at the temperature of 110 mK. The energy resolution of 9.4 eV (FWHM) was achieved for a 5899 eV Mn K al line. (author)

  7. Characterization of Ir/Au pixel TES

    International Nuclear Information System (INIS)

    Kunieda, Y.; Takahashi, H.; Zen, N.; Damayanthi, R.M.T.; Mori, F.; Fujita, K.; Nakazawa, M.; Fukuda, D.; Ohkubo, M.

    2006-01-01

    Signal shapes and noise characteristics of an asymmetrical ten-pixel Ir/Au-TES have been studied. The asymmetric design may be effective to realize an imaging spectrometer. Distinct two exponential decays observed for X-ray events are consistent with a two-step R-T curve. A theoretical thermal model for noise in multi-pixel devices reasonably explains the experimental data

  8. Design of a new non-sterile glove-dispensing unit to reduce touch-based contamination

    Directory of Open Access Journals (Sweden)

    Jennifer R Amos

    2014-06-01

    Full Text Available Background Despite best efforts by healthcare providers to sterilise their hands through hand washing prior to touching medical equipment and patients, bacteria are still present and can be spread through physical contact. We aimed to reduce the spread of touch-induced and airborne bacteria and virus spreading by using a touch-free glove-dispensing system that minimally exposes gloves in the box to air. Method The team met multiple times to undertake early prototyping and present ideas for the design. We experimented with folding gloves in varying patterns, similar to facial tissue-dispensing boxes, and tried several methods of opening/closing the glove box to determine the most effective way to access gloves with the least amount of physical contact. We considered the user experience and obtained user feedback after each design iteration. Results Ultimately, we decided on a vertically oriented box with optional holes for dispensing a glove on the side of the box or on the bottom by means of the pull-down drawer mechanism. This system will dispense a single glove at a time to the user with the option of using a pull-down drawer trigger to decrease the likelihood of physical contact with unused gloves. Both methods dispense a single glove. Conclusion: By reducing physical contact between the healthcare practitioner and the gloves, we are potentially reducing the spread of bacteria. This glove box design ensures that gloves are not exposed to the air in the clinic or hospital setting, thereby further reducing spread of airborne germs. This could assist in decreasing the risk of nosocomial infections in healthcare settings.

  9. Supplemental Security Income (SSI) / Internal Revenue Service (IRS) 1099

    Data.gov (United States)

    Social Security Administration — A finder file from SSA's Title XVI database is provided to the IRS. The IRS discloses 1099 information to SSA for use in verifying eligibility, amount, and benefits...

  10. Can formalizing links among community health workers, accredited drug dispensing outlet dispensers, and health facility staff increase their collaboration to improve prompt access to maternal and child care? A qualitative study in Tanzania.

    Science.gov (United States)

    Dillip, Angel; Kimatta, Suleiman; Embrey, Martha; Chalker, John C; Valimba, Richard; Malliwah, Mariam; Meena, John; Lieber, Rachel; Johnson, Keith

    2017-06-19

    In Tanzania, progress toward achieving the 2015 Millennium Development Goals for maternal and newborn health was slow. An intervention brought together community health workers, health facility staff, and accredited drug dispensing outlet (ADDO) dispensers to improve maternal and newborn health through a mechanism of collaboration and referral. This study explored barriers, successes, and promising approaches to increasing timely access to care by linking the three levels of health care provision. The study was conducted in the Kibaha district, where we applied qualitative approaches with in-depth interviews and focus group discussions. In-depth interview participants included retail drug shop dispensers (36), community health workers (45), and health facility staff members (15). We conducted one focus group discussion with district officials and four with mothers of newborns and children under 5 years old. Relationships among the three levels of care improved after the linkage intervention, especially for ADDO dispensers and health facility staff who previously had no formal communication pathway. The study participants perceptions of success included improved knowledge of case management and relationships among the three levels of care, more timely access to care, increased numbers of patients/customers, more meetings between community health workers and health facility staff, and a decrease in child and maternal mortality. Reported challenges included stock-outs of medicines at the health facility, participating ADDO dispensers who left to work in other regions, documentation of referrals, and lack of treatment available at health facilities on the weekend. The primary issue that threatens the sustainability of the intervention is that local council health management team members, who are responsible for facilitating the linkage, had not made any supervision visits and were therefore unaware of how the program was running. The study highlights the benefits of

  11. IGF-IR targeted therapy: Past, present and future

    NARCIS (Netherlands)

    J.A.M.J.L. Janssen (Joseph); A.J. Varewijck (Aimee)

    2014-01-01

    textabstractThe IGF-I receptor (IGF-IR) has been studied as an anti-cancer target. However, monotherapy trials with IGF-IR targeted antibodies or with IGF-IR specific tyrosine kinase inhibitors have, overall, been very disappointing in the clinical setting. This review discusses potential reasons

  12. IR Cards: Inquiry-Based Introduction to Infrared Spectroscopy

    Science.gov (United States)

    Bennett, Jacqueline; Forster, Tabetha

    2010-01-01

    As infrared spectroscopy (IR) is frequently used in undergraduate organic chemistry courses, an inductive introduction to IR spectroscopy that uses index cards printed with spectra, structures, and chemical names is described. Groups of students are given an alphabetized deck of these "IR cards" to sort into functional groups. The students then…

  13. Design, microfabrication, and characterization of a moulded PDMS/SU-8 inkjet dispenser for a Lab-on-a-Printer platform technology with disposable microfluidic chip.

    Science.gov (United States)

    Bsoul, Anas; Pan, Sheng; Cretu, Edmond; Stoeber, Boris; Walus, Konrad

    2016-08-16

    In this paper, we present a disposable inkjet dispenser platform technology and demonstrate the Lab-on-a-Printer concept, an extension of the ubiquitous Lab-on-a-Chip concept, whereby microfluidic modules are directly integrated into the printhead. The concept is demonstrated here through the integration of an inkjet dispenser and a microfluidic mixer enabling control over droplet composition from a single nozzle in real-time during printing. The inkjet dispenser is based on a modular design platform that enables the low-cost microfluidic component and the more expensive actuation unit to be easily separated, allowing for the optional disposal of the former and reuse of the latter. To limit satellite droplet formation, a hydrophobic-coated and tapered micronozzle was microfabricated and integrated with the fluidics to realize the dispenser. The microfabricated devices generated droplets with diameters ranging from 150-220 μm, depending mainly on the orifice diameter, with printing rates up to 8000 droplets per second. The inkjet dispenser is capable of dispensing materials with a viscosity up to ∼19 mPa s. As a demonstration of the inkjet dispenser function and application, we have printed type I collagen seeded with human liver carcinoma cells (cell line HepG2), to form patterned biological structures.

  14. BOOTES-IR: near IR follow-up GRB observations by a robotic system

    International Nuclear Information System (INIS)

    Castro-Tirado, A.J.; Postrigo, A. de Ugarte; Jelinek, M.

    2005-01-01

    BOOTES-IR is the extension of the BOOTES experiment, which operates in Southern Spain since 1998, to the near IR (NIR). The goal is to follow up the early stage of the gamma ray burst (GRB) afterglow emission in the NIR, alike BOOTES does already at optical wavelengths. The scientific case that drives the BOOTES-IR performance is the study of GRBs with the support of spacecraft like INTEGRAL, SWIFT and GLAST. Given that the afterglow emission in both, the NIR and the optical, in the instances immediately following a GRB, is extremely bright (reached V = 8.9 in one case), it should be possible to detect this prompt emission at NIR wavelengths too. The combined observations by BOOTES-IR and BOOTES-1 and BOOTES-2 will allow for real time identification of trustworthy candidates to have a high redshift (z > 5). It is expected that, few minutes after a GRB, the IR magnitudes be H ∼ 7-10, hence very high quality spectra can be obtained for objects as far as z = 10 by larger instruments

  15. The impact of ethnic density on dispensing of antipsychotic and antidepressant medication among immigrants in the Netherlands.

    Science.gov (United States)

    Termorshuizen, Fabian; Heerdink, Eibert R; Selten, Jean-Paul

    2018-06-12

    A higher own-group ethnic density in the area of residence is often associated with a lower risk for psychotic disorder. For common mental disorders the evidence is less convincing. This study explores whether these findings are mirrored in data on dispensing of antipsychotics and antidepressants. Health insurance data on dispensed medication among all adults living in the four largest Dutch cities were linked to demographic data from Statistics Netherlands. Dispensing of antipsychotics and antidepressants in 2013 was analyzed in relation to the proportion of the own ethnic group in the neighborhood. Higher own-group ethnic density was associated with lower dispensing of antipsychotics among the Moroccan-Dutch (N = 115,455), after adjusting for age, gender, and SES of the neighborhood (OR adj for the highest vs. the lowest density quintile = 0.72 [0.66-0.79]). However, this association vanished after adjustment for household composition (OR adj  = 0.93 [0.85-1.03]). Similar results were found for the Turkish-Dutch (N = 105,460) (OR adj  = 0.86 [0.76-0.96] and 1.05 [0.94-1.18]). For those of Surinamese (N = 147,123) and Antillean origin (N = 41,430), in contrast, the association between ethnic density and lower risk remained after each adjustment (P density was consistently found for those of Antillean origin (OR adj  = 0.62 [0.52-0.74]) only. These data on dispensing of psychomedication confirm the ethnic density hypothesis for psychosis alongside earlier equivocal findings for other mental disorders. The negative association between own-group ethnic density and dispensing of antipsychotics among the Moroccan- and Turkish-Dutch may be explained, at least in part, by a favourable household composition (i.e., living in a family) in high-density neighborhoods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Rates of opioid dispensing and overdose after introduction of abuse-deterrent extended-release oxycodone and withdrawal of propoxyphene.

    Science.gov (United States)

    Larochelle, Marc R; Zhang, Fang; Ross-Degnan, Dennis; Wharam, J Frank

    2015-06-01

    In the second half of 2010, abuse-deterrent extended-release oxycodone hydrochloride (OxyContin; Purdue Pharma) was introduced and propoxyphene was withdrawn from the US market. The effect of these pharmaceutical market changes on opioid dispensing and overdose rates is unknown. To evaluate the association between 2 temporally proximate changes in the opioid market and opioid dispensing and overdose rates. Claims from a large national US health insurer were analyzed, using an interrupted time series study design. Participants included an open cohort of 31.3 million commercially insured members aged 18 to 64 years between January 1, 2003, and December 31, 2012, with median follow-up of 20 months (last follow-up, December 31, 2012). Introduction of abuse-deterrent OxyContin (resistant to crushing or dissolving) on August 9, 2010, and market withdrawal of propoxyphene on November 19, 2010. Standardized opioid dispensing rates and prescription opioid and heroin overdose rates were the primary outcomes. We used segmented regression to analyze changes in outcomes from 30 quarters before to 8 quarters after the 2 interventions. Two years after the opioid market changes, total opioid dispensing decreased by 19% from the expected rate (absolute change, -32.2 mg morphine-equivalent dose per member per quarter [95% CI, -38.1 to -26.3]). By opioid subtype, the absolute change in dispensing by milligrams of morphine-equivalent dose per member per quarter at 2 years was -11.3 (95% CI, -12.4 to -10.1) for extended-release oxycodone, 3.26 (95% CI, 1.40 to 5.12) for other long-acting opioids, -8.19 (95% CI, -9.30 to -7.08) for propoxyphene, and -16.2 (95% CI, -18.8 to -13.5) for other immediate-release opioids. Two years after the market changes, the estimated overdose rate attributed to prescription opioids decreased by 20% (absolute change, -1.10 per 100,000 members per quarter [95% CI, -1.47 to -0.74]), but heroin overdose increased by 23% (absolute change, 0.26 per 100

  17. Characteristics of Ir/Au transition edge sensor

    International Nuclear Information System (INIS)

    Kunieda, Yuichi; Ohno, Masashi; Nakazawa, Masaharu; Takahashi, Hiroyuki; Fukuda, Daiji; Ohkubo, Masataka

    2004-01-01

    A new type of microcalorimeter has been developed using a transition edge sensor (TES) and an electro-thermal feedback (ETF) method to achieve higher energy resolution and higher count rate. We are developing a superconducting Ir-based transition edge sensor (TES) microcalorimeters. To improve thermal conductivity and achieve higher energy resolution with an Ir-TES, we fabricated an Ir/Au bilayer TES by depositing gold on Ir and investigated the influence of intermediate between superconducting and normal states at the transition edge for signal responses by microscopic observation in the Ir/Au-TES. (T. Tanaka)

  18. The Quality of Selected Essential Medicines Sold in Accredited Drug Dispensing Outlets and Pharmacies in Tanzania.

    Directory of Open Access Journals (Sweden)

    Eliangiringa Kaale

    Full Text Available The purpose of this study was to investigate the quality of a select group of medicines sold in accredited drug dispensing outlets (ADDOs and pharmacies in different regions of Tanzania as part of an in-depth cross-sectional assessment of community access to medicines and community use of medicines.We collected 242 samples of amoxicillin trihydrate, artemether-lumefantrine (ALu, co-trimoxazole, ergometrine maleate, paracetamol, and quinine from selected ADDOs and pharmacies in Mbeya, Morogoro, Singida, and Tanga regions. The analysis included physical examination and testing with validated analytical techniques. Assays for eight of nine products were conducted using high-performance thin-layer chromatography (HPTLC. For ALu tablets, we used a two-tiered approach, where tier 1 was a semi-quantitative Global Pharma Health Fund-Minilab® method and tier 2 was high-performance liquid chromatography (HPLC as described in The International Pharmacopoeia's monograph for artemether-lumefantrine.The physical examination of samples revealed no defects in the solid and oral liquid dosage forms, but unusual discoloration in an injectable solution, ergometrine maleate. For ALu, the results showed that of 38 samples, 31 (81.6% passed tier 1 testing and 7 (18.4% gave inconclusive drug content results. The inconclusive ALu samples were submitted for tier 2 testing and all met the quality standards. The pass rate using the HPTLC and TLC/HPLC assays was 93.8%; the failures were the ergometrine maleate samples purchased from both ADDOs and pharmacies. The disintegration testing of the solid dosage forms was conducted in accordance with US Pharmacopeia monographs. Only two samples of paracetamol, 1.2% of the solid dosage forms, failed to comply to standards. The study revealed a high overall rate of 92.6% of samples that met the quality standards. Although the overall failure rate was 7.4%, it is important to note that this was largely limited to one product and

  19. Tiger Teams Technical Assistance: Reliable, Universal Open Architecture for Card Access to Dispense Alternative Fuels

    Energy Technology Data Exchange (ETDEWEB)

    2002-03-01

    Report discusses the dilemma of incorporating consistent, convenient, universal card access (or ''pay-at-the-pump'') systems into alternative fueling stations across the country. The state of California continues to be in the forefront of implementing alternative fuels for transportation applications. Aggressive efforts to deploy alternative fuel vehicles (AFVs) in California have highlighted the need to provide adequate fueling stations and develop appropriate, user-friendly means to purchase fuel at the pump. Since these fuels are not typically provided by petroleum companies at conventional fueling stations, and acceptance of cash is often not an option, a payment method must be developed that is consistent with the way individual AFV operators are accustomed to purchasing automotive fuels--with a credit card. At the same time, large fleets like the California Department of General Services must be able to use a single fuel card that offers comprehensive fleet management services. The Gas Technology Institute's Infrastructure Working Group (IWG) and its stakeholders have identified the lack of a common card reader system as a hurdle to wider deployment of AFVs in California and the United States. In conjunction with the U.S. Department of Energy's (DOE) National Clean Cities Program, the IWG has outlined a multi-phased strategy to systematically address the barriers to develop a more ''open'' architecture that's similar to the way gasoline and diesel are currently dispensed. Under the auspices of the IWG, survey results were gathered (circa 1999) from certain fuel providers, as a means to more carefully study card reader issues and their potential solutions. Pilot programs featuring card reader systems capable of accepting wider payment options have been attempted in several regions of the United States with mixed success. In early 2001, DOE joined the National Renewable Energy Laboratory (NREL), the

  20. The Quality of Selected Essential Medicines Sold in Accredited Drug Dispensing Outlets and Pharmacies in Tanzania.

    Science.gov (United States)

    Kaale, Eliangiringa; Manyanga, Vicky; Chambuso, Mhina; Liana, Jafary; Rutta, Edmund; Embrey, Martha; Layloff, Thomas; Johnson, Keith

    2016-01-01

    The purpose of this study was to investigate the quality of a select group of medicines sold in accredited drug dispensing outlets (ADDOs) and pharmacies in different regions of Tanzania as part of an in-depth cross-sectional assessment of community access to medicines and community use of medicines. We collected 242 samples of amoxicillin trihydrate, artemether-lumefantrine (ALu), co-trimoxazole, ergometrine maleate, paracetamol, and quinine from selected ADDOs and pharmacies in Mbeya, Morogoro, Singida, and Tanga regions. The analysis included physical examination and testing with validated analytical techniques. Assays for eight of nine products were conducted using high-performance thin-layer chromatography (HPTLC). For ALu tablets, we used a two-tiered approach, where tier 1 was a semi-quantitative Global Pharma Health Fund-Minilab® method and tier 2 was high-performance liquid chromatography (HPLC) as described in The International Pharmacopoeia's monograph for artemether-lumefantrine. The physical examination of samples revealed no defects in the solid and oral liquid dosage forms, but unusual discoloration in an injectable solution, ergometrine maleate. For ALu, the results showed that of 38 samples, 31 (81.6%) passed tier 1 testing and 7 (18.4%) gave inconclusive drug content results. The inconclusive ALu samples were submitted for tier 2 testing and all met the quality standards. The pass rate using the HPTLC and TLC/HPLC assays was 93.8%; the failures were the ergometrine maleate samples purchased from both ADDOs and pharmacies. The disintegration testing of the solid dosage forms was conducted in accordance with US Pharmacopeia monographs. Only two samples of paracetamol, 1.2% of the solid dosage forms, failed to comply to standards. The study revealed a high overall rate of 92.6% of samples that met the quality standards. Although the overall failure rate was 7.4%, it is important to note that this was largely limited to one product and likely due to

  1. Mesoporous silica nanoparticle supported PdIr bimetal catalyst for selective hydrogenation, and the significant promotional effect of Ir

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hui; Huang, Chao; Yang, Fan [The Key Laboratory of Fuel Cell Technology of Guangdong Province, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510641 (China); Yang, Xu [Key Laboratory of Renewable Energy, Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou (China); Du, Li [The Key Laboratory of Fuel Cell Technology of Guangdong Province, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510641 (China); Key Laboratory of Renewable Energy, Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou (China); Liao, Shijun, E-mail: chsjliao@scut.edu.cn [The Key Laboratory of Fuel Cell Technology of Guangdong Province, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510641 (China); Key Laboratory of Renewable Energy, Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou (China)

    2015-12-01

    Graphical abstract: A mesoporous silica nanoparticle (MSN) supported bimetal catalyst, PdIr/MSN, was prepared by a facile impregnation and hydrogen reduction method. The strong promotional effect of Ir was observed and thoroughly investigated. At the optimal molar ratio of Ir to Pd (N{sub Ir}/N{sub Pd} = 0.1), the activity of PdIr{sub 0.1}/MSN was up to eight times and 28 times higher than that of monometallic Pd/MSN and Ir/MSN, respectively. The catalysts were characterized comprehensively by X-ray diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, and hydrogen temperature programmed reduction, which revealed that the promotional effect of Ir may be due to the enhanced dispersion of active components on the MSN, and to the intensified Pd–Ir electronic interaction caused by the addition of Ir. - Highlights: • Mesoporous nanoparticles were synthesized and used as support for metal catalyst. • PdIr bimetallic catalyst exhibited significantly improved hydrogenation activity. • The strong promotion of Ir was recognized firstly and investigated intensively. • PdIr exhibits 18 times higher activity than Pd to the hydrogenation of nitrobenzene. - Abstract: A mesoporous silica nanoparticle (MSN) supported bimetal catalyst, PdIr/MSN, was prepared by a facile impregnation and hydrogen reduction method. The strong promotional effect of Ir was observed and thoroughly investigated. At the optimal molar ratio of Ir to Pd (N{sub Ir}/N{sub Pd} = 0.1), the activity of PdIr{sub 0.1}/MSN was up to eight times and 28 times higher than that of monometallic Pd/MSN and Ir/MSN, respectively. The catalysts were characterized comprehensively by X-ray diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, and hydrogen temperature programmed reduction, which revealed that the promotional effect of Ir may be due to the enhanced dispersion of active components on the MSN, and to the intensified Pd–Ir electronic interaction

  2. Controlling Hydrogenation of Graphene on Ir(111)

    DEFF Research Database (Denmark)

    Balog, Richard; Andersen, Mie; Jørgensen, Bjarke

    2013-01-01

    Combined fast X-ray photoelectron spectroscopy and density functional theory calculations reveal the presence of two types of hydrogen adsorbate structures at the graphene/ Ir(111) interface, namely, graphane-like islands and hydrogen dimer structures. While the former give rise to a periodic...... pattern, dimers tend to destroy the periodicity. Our data reveal distinctive growth rates and stability of both types of structures, thereby allowing one to obtain well-defined patterns of hydrogen clusters. The ability to control and manipulate the formation and size of hydrogen structures on graphene...

  3. PEP-II IR-2 Alignment

    International Nuclear Information System (INIS)

    Seryi, A

    2004-01-01

    This paper describes the first results and preliminary analysis obtained with several alignment monitoring systems recently installed in the PEP-II interaction region. The hydrostatic level system, stretched wire system, and laser tracker have been installed in addition to the existing tiltmeters and LVDT sensors. These systems detected motion of the left raft, which correlated primarily with the low energy ring (LER) current. The motion is of the order of 120 micrometers. The cause was identified as synchrotron radiation heating the beampipe, causing its expansion which then results in its deformation and offset of the IR quadrupoles. We also discuss further plans on measurements, analysis and means to counteract this motion

  4. Computer dosimetry of 192Ir wire

    International Nuclear Information System (INIS)

    Kline, R.W.; Gillin, M.T.; Grimm, D.F.; Niroomand-Rad, A.

    1985-01-01

    The dosimetry of 192 Ir linear sources with a commercial treatment planning computer system has been evaluated. Reference dose rate data were selected from the literature and normalized in a manner consistent with our clinical and dosimetric terminology. The results of the computer calculations are compared to the reference data and good agreement is shown at distances within about 7 cm from a linear source. The methodology of translating source calibration in terms of exposure rate for use in the treatment planning computer is developed. This may be useful as a practical guideline for users of similar computer calculation programs for iridium as well as other sources

  5. Pixelated coatings and advanced IR coatings

    Science.gov (United States)

    Pradal, Fabien; Portier, Benjamin; Oussalah, Meihdi; Leplan, Hervé

    2017-09-01

    Reosc developed pixelated infrared coatings on detector. Reosc manufactured thick pixelated multilayer stacks on IR-focal plane arrays for bi-spectral imaging systems, demonstrating high filter performance, low crosstalk, and no deterioration of the device sensitivities. More recently, a 5-pixel filter matrix was designed and fabricated. Recent developments in pixelated coatings, shows that high performance infrared filters can be coated directly on detector for multispectral imaging. Next generation space instrument can benefit from this technology to reduce their weight and consumptions.

  6. Stringy horizons and UV/IR mixing

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Israel, Roy [Physics Department, Tel-Aviv University Israel,Ramat-Aviv, 69978 (Israel); Giveon, Amit [Racah Institute of Physics, The Hebrew University,Jerusalem, 91904 (Israel); Itzhaki, Nissan; Liram, Lior [Physics Department, Tel-Aviv University Israel,Ramat-Aviv, 69978 (Israel)

    2015-11-24

    The target-space interpretation of the exact (in α{sup ′}) reflection coefficient for scattering from Euclidean black-hole horizons in classical string theory is studied. For concreteness, we focus on the solvable SL(2,ℝ){sub k}/U(1) black hole. It is shown that it exhibits a fascinating UV/IR mixing, dramatically modifying the late-time behavior of general relativity. We speculate that this might play an important role in the black-hole information puzzle, as well as in clarifying features related with the non-locality of Little String Theory.

  7. Atsiskaitymai e. versle: ypatumai ir naujos tendencijos

    OpenAIRE

    Vyšniauskas, Jonas

    2014-01-01

    Alternatyvių atsiskaitymų e. versle sistemos pradeda kelti rimtą grėsmę tradiciniams atsiskaitymams elektronine bankininkyste, mokėjimo kortelėmis ar grynaisiais pinigais. Todėl būtina detaliau išsiaiškinti kokie yra alternatyvių atsiskaitymų ypatumai, kurie veiksniai vartotojams yra svarbiausi ir kokie yra alternatyvūs atsiskaitymo būdai. Tai siekiama padaryti išanalizuojant mokslinę literatūrą, pateikiant pagrindines alternatyvių atsiskaitymų sistemas, atliekant alternatyvių atsiskaitymų pa...

  8. Fast IR diodes thermometer for tokamak

    International Nuclear Information System (INIS)

    Chen Xiangbo

    2001-01-01

    A 30 channel fast IR pyrometry array has been constructed for tokamak, which has 0.5 μs time response, 10 mm diameter spatial resolution and 5 degree C temperature resolution. The temperature measuring range is from 250 degree C to 1200 degree C. The two dimensional temperature profiles of the first wall during both major and minor disruptions can be measured with an accuracy of about 1% measuring temperature, which is adequate for tokamak experiments. This gives a very useful tool for the disruption study, especially for the divertor physics and edge heat flux research on tokamak and other magnetic confinement devices

  9. Design and Development of transducer for IR radiation measurement

    International Nuclear Information System (INIS)

    Pattarachindanuwong, Surat; Poopat, Bovornchoke; Meethong, Wachira

    2003-06-01

    Recently, IR radiation has many important roles such as for plastics industry, food industry and medical instrumentation. The consequence of exposed irradiation objects from IR can be greatly affected by the quantity of IR radiation. Therefore the objectively this research is to design and develop a transducer for IR radiation measurement. By using a quartz halogen lamp as a IR heat source of IR radiation and a thermopile sensor as a transducer. The thermal conductivity of transducer and air flow, were also considered for design and development of transducer. The study shows that the designed transducer can be used and applied in high temperature process, for example, the quality control of welding, the non-contact temperature measurement of drying oven and the testing of IR source in medical therapy device

  10. Evolution of the vertebrate insulin receptor substrate (Irs) gene family.

    Science.gov (United States)

    Al-Salam, Ahmad; Irwin, David M

    2017-06-23

    Insulin receptor substrate (Irs) proteins are essential for insulin signaling as they allow downstream effectors to dock with, and be activated by, the insulin receptor. A family of four Irs proteins have been identified in mice, however the gene for one of these, IRS3, has been pseudogenized in humans. While it is known that the Irs gene family originated in vertebrates, it is not known when it originated and which members are most closely related to each other. A better understanding of the evolution of Irs genes and proteins should provide insight into the regulation of metabolism by insulin. Multiple genes for Irs proteins were identified in a wide variety of vertebrate species. Phylogenetic and genomic neighborhood analyses indicate that this gene family originated very early in vertebrae evolution. Most Irs genes were duplicated and retained in fish after the fish-specific genome duplication. Irs genes have been lost of various lineages, including Irs3 in primates and birds and Irs1 in most fish. Irs3 and Irs4 experienced an episode of more rapid protein sequence evolution on the ancestral mammalian lineage. Comparisons of the conservation of the proteins sequences among Irs paralogs show that domains involved in binding to the plasma membrane and insulin receptors are most strongly conserved, while divergence has occurred in sequences involved in interacting with downstream effector proteins. The Irs gene family originated very early in vertebrate evolution, likely through genome duplications, and in parallel with duplications of other components of the insulin signaling pathway, including insulin and the insulin receptor. While the N-terminal sequences of these proteins are conserved among the paralogs, changes in the C-terminal sequences likely allowed changes in biological function.

  11. Spin orientations of the spin-half Ir(4+) ions in Sr3NiIrO6, Sr2IrO4, and Na2IrO3: Density functional, perturbation theory, and Madelung potential analyses.

    Science.gov (United States)

    Gordon, Elijah E; Xiang, Hongjun; Köhler, Jürgen; Whangbo, Myung-Hwan

    2016-03-21

    The spins of the low-spin Ir(4+) (S = 1/2, d(5)) ions at the octahedral sites of the oxides Sr3NiIrO6, Sr2IrO4, and Na2IrO3 exhibit preferred orientations with respect to their IrO6 octahedra. We evaluated the magnetic anisotropies of these S = 1/2 ions on the basis of density functional theory (DFT) calculations including spin-orbit coupling (SOC), and probed their origin by performing perturbation theory analyses with SOC as perturbation within the LS coupling scheme. The observed spin orientations of Sr3NiIrO6 and Sr2IrO4 are correctly predicted by DFT calculations, and are accounted for by the perturbation theory analysis. As for the spin orientation of Na2IrO3, both experimental studies and DFT calculations have not been unequivocal. Our analysis reveals that the Ir(4+) spin orientation of Na2IrO3 should have nonzero components along the c- and a-axis directions. The spin orientations determined by DFT calculations are sensitive to the accuracy of the crystal structures employed, which is explained by perturbation theory analyses when interactions between adjacent Ir(4+) ions are taken into consideration. There are indications implying that the 5d electrons of Na2IrO3 are less strongly localized compared with those of Sr3NiIrO6 and Sr2IrO4. This implication was confirmed by showing that the Madelung potentials of the Ir(4+) ions are less negative in Na2IrO3 than in Sr3NiIrO6 and Sr2IrO4. Most transition-metal S = 1/2 ions do have magnetic anisotropies because the SOC induces interactions among their crystal-field split d-states, and the associated mixing of the states modifies only the orbital parts of the states. This finding cannot be mimicked by a spin Hamiltonian because this model Hamiltonian lacks the orbital degree of freedom, thereby leading to the spin-half syndrome. The spin-orbital entanglement for the 5d spin-half ions Ir(4+) is not as strong as has been assumed.

  12. The detectability of cracks using sonic IR

    Science.gov (United States)

    Morbidini, Marco; Cawley, Peter

    2009-05-01

    This paper proposes a methodology to study the detectability of fatigue cracks in metals using sonic IR (also known as thermosonics). The method relies on the validation of simple finite-element thermal models of the cracks and specimens in which the thermal loads have been defined by means of a priori measurement of the additional damping introduced in the specimens by each crack. This estimate of crack damping is used in conjunction with a local measurement of the vibration strain during ultrasonic excitation to retrieve the power released at the crack; these functions are then input to the thermal model of the specimens to find the resulting temperature rises (sonic IR signals). The method was validated on mild steel beams with two-dimensional cracks obtained in the low-cycle fatigue regime as well as nickel-based superalloy beams with three-dimensional "thumbnail" cracks generated in the high-cycle fatigue regime. The equivalent 40kHz strain necessary to obtain a desired temperature rise was calculated for cracks in the nickel superalloy set, and the detectability of cracks as a function of length in the range of 1-5mm was discussed.

  13. Irène Jacob visits CERN

    CERN Document Server

    CERN Bulletin

    2010-01-01

    French actress Irène Jacob, the daughter of physicist Maurice Jacob, visited the ATLAS and CMS control rooms on Monday 17 May together with Italian theatre actor-director Pippo Delbono, in search of inspiration for a short film. The film will be screened at the “nuit des particules” event accompanying this year’s ICHEP.   Pippo Delbono et Irène Jacob discussing their project. “La nuit des particules” (night of the particles) is an event open to the general public that is being organised for the evening of Tuesday, 27 July, to accompany the 35th International Conference on High Energy Physics (ICHEP). ICHEP is a major highlight in every physicist’s calendar, and this year’s edition is being held in Paris from 22 to 28 July. The short film will be screened during the evening, which will include a lecture and a show at the legendary Parisian cinema Le Grand Rex, with a colossal seating capacity of 2 700 spe...

  14. Extension of the commercial agreement on water dispensers: appendices 1-4; Erweiterung der Branchenvereinbarung Wasserdispenser. Anhaenge 1-4

    Energy Technology Data Exchange (ETDEWEB)

    Grieder, T.; Huser, A.

    2006-07-01

    These appendices to a final report for the Swiss Federal Office of Energy (SFOE) present the results of work done within the framework of a voluntary agreement between the Federal Office of Energy and the four most important suppliers of bottled water dispensers in Switzerland. The first appendix lists water dispensers with water-mains connections and quotes figures on the number of units and their energy use. Two prognoses are presented for the year 2015, one with and one without any action being taken. The second appendix presents the German Gas and Water association's suggestion for standards, while the third appendix presents the hygiene regulations of the Swiss Department of Home Affairs. The fourth appendix presents the answer sent by the U.S.A's Environmental Protection Agency to an e-mail on the subject.

  15. Providers' knowledge, attitude and dispensing practices of e-pills in government dispensaries of South district in delhi, India.

    Science.gov (United States)

    Kishore, Vertika; Misro, Man M; Nandan, Deoki

    2010-01-01

    South Delhi is one of the well developed districts in the capital with best public health care facilities. Knowledge, attitude and dispensing practices of emergency contraceptive pills (E-pills) were assessed among health care providers of government dispensaries in South Delhi. A descriptive epidemiological study. Both medical and paramedical (n = 428) providers in 63 government health care facilities were interviewed between August to December 2007 using a semi-structured interview schedule. Among the different categories of the providers, medical officers were observed to be most knowledgeable about E-pills and the pharmacists were the least. The correct prescribed dose of E-pill was known only to 32% of the providers while 49% knew about its right time of intake. Misconceptions and apprehensions for promoting its use were very much prevalent even among medical officers as majority felt that open access to E-pills would increase promiscuity. The dispensing practice of providers was found positively (P pills.

  16. Making the case for change: What researchers need to consider when designing behavior change interventions aimed at improving medication dispensing.

    Science.gov (United States)

    Cadogan, Cathal A; Ryan, Cristín; Hughes, Carmel

    2016-01-01

    There is a growing emphasis on behavior change in intervention development programmes aimed at improving public health and healthcare professionals' practice. A number of frameworks and methodological tools have been established to assist researchers in developing interventions seeking to change healthcare professionals' behaviors. The key features of behavior change intervention design involve specifying the target group (i.e. healthcare professional or patient cohort), the target behavior and identifying mediators (i.e. barriers and facilitators) of behavior change. Once the target behavior is clearly specified and understood, specific behavior change techniques can then be used as the basis of the intervention to target identified mediators of behavior change. This commentary outlines the challenges for pharmacy practice-based researchers in targeting dispensing as a behavior when developing behavior change interventions aimed at pharmacists and proposes a definition of dispensing to consider in future research. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Multi-pulsed intense electron beam emission from velvet, carbon fibers, carbon nano-tubes and dispenser cathodes

    International Nuclear Information System (INIS)

    Xia Liansheng; Yang Anmin; Chen Yi; Zhang Huang; Liu Xingguang; Li Jin; Jiang Xiaoguo; Zhang Kaizhi; Shi Jinshui; Deng Jianjun; Zhang Linwen

    2010-01-01

    The experimental results of studies of four kinds of cathode emitting intense electron beams are demonstrated under multi-pulsed mode based on an experimental setup including two multi-pulse high voltage sources. The tested cathodes include velvet, carbon fibers, carbon nano-tubes (CNTs) and dispenser cathodes. The results indicate that all four are able to emit multi-pulsed beams. For velvet, carbon fiber and CNTs, the electron induced cathode plasma emission may be the main process and this means that there are differences in beam parameters from pulse to pulse. For dispenser cathodes tested in the experiment, although there is a little difference from pulse to pulse for some reason, thermal-electric field emission may be the main process. (authors)

  18. Early experiences with the multidose drug dispensing system – A matter of trust?

    Science.gov (United States)

    Wekre, Liv Johanne; Melby, Line; Grimsmo, Anders

    2011-01-01

    Objective To study early experiences with multidose drug dispensing (MDD) among different groups of health personnel. Design Qualitative study based on focus-group interviews. Setting Primary health care, Trondheim, Norway. Main outcome The importance of trust in the technology and in collaborating partners is actualized in the early implementation of MDD. Results GPs, home-care nurses, pharmacists, and medical secretaries trusted the new MDD technology. The quality of the GPs’ medication records improved. However, health personnel, including the GPs themselves, would not always trust the medication records of the GPs. Checking the multidose bags arriving from the pharmacy was considered unnecessary in the written routines dealing with MDD. However, home-care nurses experienced errors and continued to manually check the bags. Nurses in the home-care service felt a loss of knowledge with regard to the patients’ medications and in turn experienced reduced ability to give medical information to patients and to observe the effects of the drugs. The home-care services’ routines for drug handling were not always trusted by the other groups of health personnel involved. Conclusion Health personnel faced some challenges during the implementation of the MDD system, but most of them remained confident in the new system. Building trust has to be a process that runs in parallel with the introduction of new technology and the establishment of new routines for improving the quality in handling of medicines and to facilitate better cooperation and communication. PMID:21323496

  19. [Economic impact of an automated dispensing system in an intensive care unit].

    Science.gov (United States)

    Kheniene, F; Bedouch, P; Durand, M; Marie, F; Brudieu, E; Tourlonnias, M-M; Bongi, P; Allenet, B; Calop, J

    2008-03-01

    Automated dispensing systems (ADS) allow a reduction of medication errors and an improvement of drug distribution in clinical ward. The objective of this study was to evaluate the economic impact of ADS in an intensive care unit. A cost-benefit model was constructed based on the hospital perspective. The system was evaluated before-after implementation of an ADS in a 12-bed cardiovascular intensive care unit of a French teaching hospital: (a) by a measuring nurse and pharmacy technician working time required for various tasks; (b) by measuring the cost of drug storage and the cost of expired drug; (c) by measuring the nurses' acceptability. After ADS was installed, nursing personnel spent less time on medication-related activities (mean of 1.9 hour/day of nursing time). Pharmacy technicians spent more time on floor-stock activities (mean of 0.7 hour/day of technician time). Implementation reduced the cost of drug storage by 56% (14,742 euros) and cost of expired drug by 9,086 euros per year. Finally, cost-benefit analysis including potential savings in terms of working time showed a net benefit of 71,586 euros (14,317 euros/year). The ADS was given high marks by the nurses; 77% wanted to keep it on their unit. Implementation of ADS is expected to generate direct savings for the hospital and working time reallocation, for nurses to interact with patients and for pharmacy technicians to get involved on the ward.

  20. Flux through the tetrahydrodipicolinate succinylase pathway is dispensable for L-lysine production in Corynebacterium glutamicum.

    Science.gov (United States)

    Shaw-Reid, C A; McCormick, M M; Sinskey, A J; Stephanopoulos, G

    1999-03-01

    The N-succinyl-LL-diaminopimelate desuccinylase gene (dapE) in the four-step succinylase branch of the L-lysine biosynthetic pathway of Corynebacterium glutamicum was disrupted via marker-exchange mutagenesis to create a mutant strain that uses only the one-step meso-diaminopimelate dehydrogenase branch to overproduce lysine. This mutant strain grew and utilized glucose from minimal medium at the same rate as the parental strain. In addition, the dapE- strain produced lysine at the same rate as its parent strain. Transformation of the parental and dapE- strains with the amplified meso-diaminopimelate dehydrogenase gene (ddh) on a plasmid did not affect lysine production in either strain, despite an eightfold amplification of the activity of the enzyme. These results indicate that the four-step succinylase pathway is dispensable for lysine overproduction in shake-flask culture. In addition, the one-step meso-diaminopimelate dehydrogenase pathway does not limit lysine flux in Corynebacterium under these conditions.

  1. AMPKγ3 is dispensable for skeletal muscle hypertrophy induced by functional overload.

    Science.gov (United States)

    Riedl, Isabelle; Osler, Megan E; Björnholm, Marie; Egan, Brendan; Nader, Gustavo A; Chibalin, Alexander V; Zierath, Juleen R

    2016-03-15

    Mechanisms regulating skeletal muscle growth involve a balance between the activity of serine/threonine protein kinases, including the mammalian target of rapamycin (mTOR) and 5'-AMP-activated protein kinase (AMPK). The contribution of different AMPK subunits to the regulation of cell growth size remains inadequately characterized. Using AMPKγ3 mutant-overexpressing transgenic Tg-Prkag3(225Q) and AMPKγ3-knockout (Prkag3(-/-)) mice, we investigated the requirement for the AMPKγ3 isoform in functional overload-induced muscle hypertrophy. Although the genetic disruption of the γ3 isoform did not impair muscle growth, control sham-operated AMPKγ3-transgenic mice displayed heavier plantaris muscles in response to overload hypertrophy and underwent smaller mass gain and lower Igf1 expression compared with wild-type littermates. The mTOR signaling pathway was upregulated with functional overload but unchanged between genetically modified animals and wild-type littermates. Differences in AMPK-related signaling pathways between transgenic, knockout, and wild-type mice did not impact muscle hypertrophy. Glycogen content was increased following overload in wild-type mice. In conclusion, our functional, transcriptional, and signaling data provide evidence against the involvement of the AMPKγ3 isoform in the regulation of skeletal muscle hypertrophy. Thus, the AMPKγ3 isoform is dispensable for functional overload-induced muscle growth. Mechanical loading can override signaling pathways that act as negative effectors of mTOR signaling and consequently promote skeletal muscle hypertrophy. Copyright © 2016 the American Physiological Society.

  2. Mast cells are dispensable in a genetic mouse model of chronic dermatitis.

    Science.gov (United States)

    Sulcova, Jitka; Meyer, Michael; Guiducci, Eva; Feyerabend, Thorsten B; Rodewald, Hans-Reimer; Werner, Sabine

    2015-06-01

    Chronic inflammatory skin diseases, such as atopic dermatitis, affect a large percentage of the population, but the role of different immune cells in the pathogenesis of these disorders is largely unknown. Recently, we found that mice lacking fibroblast growth factor receptor 1 (Fgfr1) and Fgfr2 (K5-R1/R2 mice) in the epidermis have a severe impairment in the epidermal barrier, which leads to the development of a chronic inflammatory skin disease that shares many features with human atopic dermatitis. Using Fgfr1-/Fgfr2-deficient mice, we analyzed the consequences of the loss of mast cells. Mast cells accumulated and degranulated in the skin of young Fgfr1-/Fgfr2-deficient mice, most likely as a consequence of increased expression of the mast cell chemokine Ccl2. The increase in mast cells occurred before the development of histological abnormalities, indicating a functional role of these cells in the inflammatory skin phenotype. To test this hypothesis, we mated the Fgfr1-/Fgfr2-deficient mice with mast cell-deficient CreMaster mice. Surprisingly, loss of mast cells did not or only mildly affect keratinocyte proliferation, epidermal thickness, epidermal barrier function, accumulation and activation of different immune cells, or expression of different proinflammatory cytokines in the skin. These results reveal that mast cells are dispensable for the development of chronic inflammation in response to a defect in the epidermal barrier. Copyright © 2015 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  3. Identification of vital and dispensable sulfur utilization factors in the Plasmodium apicoplast.

    Directory of Open Access Journals (Sweden)

    Joana M Haussig

    Full Text Available Iron-sulfur [Fe-S] clusters are ubiquitous and critical cofactors in diverse biochemical processes. They are assembled by distinct [Fe-S] cluster biosynthesis pathways, typically in organelles of endosymbiotic origin. Apicomplexan parasites, including Plasmodium, the causative agent of malaria, harbor two separate [Fe-S] cluster biosynthesis pathways in the their mitochondrion and apicoplast. In this study, we systematically targeted the five nuclear-encoded sulfur utilization factors (SUF of the apicoplast [Fe-S] cluster biosynthesis pathway by experimental genetics in the murine malaria model parasite Plasmodium berghei. We show that four SUFs, namely SUFC, D, E, and S are refractory to targeted gene deletion, validating them as potential targets for antimalarial drug development. We achieved targeted deletion of SUFA, which encodes a potential [Fe-S] transfer protein, indicative of a dispensable role during asexual blood stage growth in vivo. Furthermore, no abnormalities were observed during Plasmodium life cycle progression in the insect and mammalian hosts. Fusion of a fluorescent tag to the endogenous P. berghei SUFs demonstrated that all loci were accessible to genetic modification and that all five tagged SUFs localize to the apicoplast. Together, our experimental genetics analysis identifies the key components of the SUF [Fe-S] cluster biosynthesis pathway in the apicoplast of a malarial parasite and shows that absence of SUFC, D, E, or S is incompatible with Plasmodium blood infection in vivo.

  4. TMEM45A Is Dispensable for Epidermal Morphogenesis, Keratinization and Barrier Formation.

    Directory of Open Access Journals (Sweden)

    Aurélie Hayez

    Full Text Available TMEM45A gene encodes an initially uncharacterized predicted transmembrane protein. We previously showed that this gene is highly expressed in keratinocytes where its expression correlates with keratinization, suggesting a role in normal epidermal physiology. To test this hypothesis, we generated TMEM45A knockout mice and found that these mice develop without any evident phenotype. The morphology of the epidermis assessed by histology and by labelling differentiation markers in immunofluorescence was not altered. Toluidine blue permeability assay showed that the epidermal barrier develops normally during embryonic development. We also showed that depletion of TMEM45A in human keratinocytes does not alter their potential to form in vitro 3D-reconstructed epidermis. Indeed, epidermis with normal morphogenesis were generated from TMEM45A-silenced keratinocytes. Their expression of differentiation markers quantified by RT-qPCR and evidenced by immunofluorescence labelling as well as their barrier function estimated by Lucifer yellow permeability were similar to the control epidermis. In summary, TMEM45A gene expression is dispensable for epidermal morphogenesis, keratinization and barrier formation. If this protein plays a role in the epidermis, its experimental depletion can possibly be compensated by other proteins in the two experimental models analyzed in this study.

  5. Fibroblast activation protein is dispensable in the anti-influenza immune response in mice.

    Directory of Open Access Journals (Sweden)

    Sioh-Yang Tan

    Full Text Available Fibroblast activation protein alpha (FAP is a unique dual peptidase of the S9B serine protease family, being capable of both dipeptidyl peptidase and endopeptidase activities. FAP is expressed at low level in healthy adult organs including the pancreas, cervix, uterus, submaxillary gland and the skin, and highly upregulated in embryogenesis, chronic inflammation and tissue remodelling. It is also expressed by cancer-associated stromal fibroblasts in more than 90% of epithelial tumours. FAP has enzymatic and non-enzymatic functions in the growth, immunosuppression, invasion and cell signalling of tumour cells. FAP deficient mice are fertile and viable with no gross abnormality, but little data exist on the role of FAP in the immune system. FAP is upregulated in association with microbial stimulation and chronic inflammation, but its function in infection remains unknown. We showed that major populations of immune cells including CD4+ and CD8+ T cells, B cells, dendritic cells and neutrophils are generated and maintained normally in FAP knockout mice. Upon intranasal challenge with influenza virus, FAP mRNA was increased in the lungs and lung-draining lymph nodes. Nonetheless, FAP deficient mice showed similar pathologic kinetics to wildtype controls, and were capable of supporting normal anti-influenza T and B cell responses. There was no evidence of compensatory upregulation of other DPP4 family members in influenza-infected FAP-deficient mice. FAP appears to be dispensable in anti-influenza adaptive immunity.

  6. Theoretical study for heterojunction surface of NEA GaN photocathode dispensed with Cs activation

    Science.gov (United States)

    Xia, Sihao; Liu, Lei; Wang, Honggang; Wang, Meishan; Kong, Yike

    2016-09-01

    For the disadvantages of conventional negative electron affinity (NEA) GaN photocathodes activated by Cs or Cs/O, new-type NEA GaN photocathodes with heterojunction surface dispensed with Cs activation are investigated based on first-principle study with density functional theory. Through the growth of an ultrathin n-type GaN cap layer on p-type GaN emission layer, a p-n heterojunction is formed on the surface. According to the calculation results, it is found that Si atoms tend to replace Ga atoms to result in an n-type doped cap layer which contributes to the decreasing of work function. After the growth of n-type GaN cap layer, the atom structure near the p-type emission layer is changed while that away from the surface has no obvious variations. By analyzing the E-Mulliken charge distribution of emission surface with and without cap layer, it is found that the positive charge of Ga and Mg atoms in the emission layer decrease caused by the cap layer, while the negative charge of N atom increases. The conduction band moves downwards after the growth of cap layer. Si atom produces donor levels around the valence band maximum. The absorption coefficient of GaN emission layer decreases and the reflectivity increases caused by n-type GaN cap layer.

  7. Automated drug dispensing systems in the intensive care unit: a financial analysis.

    Science.gov (United States)

    Chapuis, Claire; Bedouch, Pierrick; Detavernier, Maxime; Durand, Michel; Francony, Gilles; Lavagne, Pierre; Foroni, Luc; Albaladejo, Pierre; Allenet, Benoit; Payen, Jean-Francois

    2015-09-09

    To evaluate the economic impact of automated-drug dispensing systems (ADS) in surgical intensive care units (ICUs). A financial analysis was conducted in three adult ICUs of one university hospital, where ADS were implemented, one in each unit, to replace the traditional floor stock system. Costs were estimated before and after implementation of the ADS on the basis of floor stock inventories, expired drugs, and time spent by nurses and pharmacy technicians on medication-related work activities. A financial analysis was conducted that included operating cash flows, investment cash flows, global cash flow and net present value. After ADS implementation, nurses spent less time on medication-related activities with an average of 14.7 hours saved per day/33 beds. Pharmacy technicians spent more time on floor-stock activities with an average of 3.5 additional hours per day across the three ICUs. The cost of drug storage was reduced by €44,298 and the cost of expired drugs was reduced by €14,772 per year across the three ICUs. Five years after the initial investment, the global cash flow was €148,229 and the net present value of the project was positive by €510,404. The financial modeling of the ADS implementation in three ICUs showed a high return on investment for the hospital. Medication-related costs and nursing time dedicated to medications are reduced with ADS.

  8. Aurora B is dispensable for megakaryocyte polyploidization, but contributes to the endomitotic process.

    Science.gov (United States)

    Lordier, Larissa; Chang, Yunhua; Jalil, Abdelali; Aurade, Frédéric; Garçon, Loïc; Lécluse, Yann; Larbret, Frédéric; Kawashima, Toshiyuki; Kitamura, Toshio; Larghero, Jérôme; Debili, Najet; Vainchenker, William

    2010-09-30

    Polyploidization of megakaryocytes (MKs), the platelet precursors, occurs by endomitosis, a mitotic process that fails at late stages of cytokinesis. Expression and function of Aurora B kinase during endomitosis remain controversial. Here, we report that Aurora B is normally expressed during the human MK endomitotic process. Aurora B localized normally in the midzone or midbody during anaphase and telophase in low ploidy megakaryocytes and in up to 16N rare endomitotic MKs was observed. Aurora B was also functional during cytokinesis as attested by phosphorylation of both its activation site and MgcRacGAP, its main substrate. However, despite its activation, Aurora B did not prevent furrow regression. Inhibition of Aurora B by AZD1152-HQPA decreased cell cycle entry both in 2N to 4N and polyploid MKs and induced apoptosis mainly in 2N to 4N cells. In both MK classes, AZD1152-HQPA induced p53 activation and retinoblastoma hypophosphorylation. Resistance of polyploid MKs to apoptosis correlated to a high BclxL level. Aurora B inhibition did not impair MK polyploidization but profoundly modified the endomitotic process by inducing a mis-segregation of chromosomes and a mitotic failure in anaphase. This indicates that Aurora B is dispensable for MK polyploidization but is necessary to achieve a normal endomitotic process.

  9. The Histone Methyltransferase Activity of MLL1 Is Dispensable for Hematopoiesis and Leukemogenesis

    Directory of Open Access Journals (Sweden)

    Bibhu P. Mishra

    2014-05-01

    Full Text Available Despite correlations between histone methyltransferase (HMT activity and gene regulation, direct evidence that HMT activity is responsible for gene activation is sparse. We address the role of the HMT activity for MLL1, a histone H3 lysine 4 (H3K4 methyltransferase critical for maintaining hematopoietic stem cells (HSCs. Here, we show that the SET domain, and thus HMT activity of MLL1, is dispensable for maintaining HSCs and supporting leukemogenesis driven by the MLL-AF9 fusion oncoprotein. Upon Mll1 deletion, histone H4 lysine 16 (H4K16 acetylation is selectively depleted at MLL1 target genes in conjunction with reduced transcription. Surprisingly, inhibition of SIRT1 is sufficient to prevent the loss of H4K16 acetylation and the reduction in MLL1 target gene expression. Thus, recruited MOF activity, and not the intrinsic HMT activity of MLL1, is central for the maintenance of HSC target genes. In addition, this work reveals a role for SIRT1 in opposing MLL1 function.

  10. Mouse Panx1 Is Dispensable for Hearing Acquisition and Auditory Function.

    Science.gov (United States)

    Zorzi, Veronica; Paciello, Fabiola; Ziraldo, Gaia; Peres, Chiara; Mazzarda, Flavia; Nardin, Chiara; Pasquini, Miriam; Chiani, Francesco; Raspa, Marcello; Scavizzi, Ferdinando; Carrer, Andrea; Crispino, Giulia; Ciubotaru, Catalin D; Monyer, Hannah; Fetoni, Anna R; M Salvatore, Anna; Mammano, Fabio

    2017-01-01

    Panx1 forms plasma membrane channels in brain and several other organs, including the inner ear. Biophysical properties, activation mechanisms and modulators of Panx1 channels have been characterized in detail, however the impact of Panx1 on auditory function is unclear due to conflicts in published results. To address this issue, hearing performance and cochlear function of the Panx1 -/- mouse strain, the first with a reported global ablation of Panx1 , were scrutinized. Male and female homozygous ( Panx1 -/-), hemizygous ( Panx1 +/-) and their wild type (WT) siblings ( Panx1 +/+) were used for this study. Successful ablation of Panx1 was confirmed by RT-PCR and Western immunoblotting in the cochlea and brain of Panx1 -/- mice. Furthermore, a previously validated Panx1-selective antibody revealed strong immunoreactivity in WT but not in Panx1 -/- cochleae. Hearing sensitivity, outer hair cell-based "cochlear amplifier" and cochlear nerve function, analyzed by auditory brainstem response (ABR) and distortion product otoacoustic emission (DPOAE) recordings, were normal in Panx1 +/- and Panx1 -/- mice. In addition, we determined that global deletion of Panx1 impacts neither on connexin expression, nor on gap-junction coupling in the developing organ of Corti. Finally, spontaneous intercellular Ca 2+ signal (ICS) activity in organotypic cochlear cultures, which is key to postnatal development of the organ of Corti and essential for hearing acquisition, was not affected by Panx1 ablation. Therefore, our results provide strong evidence that, in mice, Panx1 is dispensable for hearing acquisition and auditory function.

  11. Dispensers, obeah and quackery: medical rivalries in post-slavery British Guiana.

    Science.gov (United States)

    De Barros, Juanita

    2007-08-01

    This paper examines the ambiguous place of medical assistants-dispensers-in a post-slavery British Caribbean colony, British Guiana, from the end of slavery in the 1830s to the early twentieth century. Although the latter were crucial to the functioning of the colonial medical system, local physicians resented them, complaining about the economic threat they posed and at times condemning them as quacks. These attacks were part of a wider discussion about the composition of the medical profession and the role of medical auxiliaries in colonial society, and to an extent, they echoed debates conducted in other jurisdictions in this period. But in the British Caribbean, this discussion was significantly different. There, long-standing views about obeah-an Afro-Creole medico-religious practice-as a particularly dangerous and uncivilised type of quackery was part of the discursive context. That those participating in this debate included African-descended physicians whose arrival in the medical profession was recent and contested demonstrates the vexed and complex nature of professionalisation in a post-slavery society.

  12. Influence of pharmacists' opinions on their dispensing medicines without requirement of a doctor's prescription

    Directory of Open Access Journals (Sweden)

    Francisco Caamaño

    2005-02-01

    Full Text Available Objective: To assess the influence of pharmacists' opinions on their dispensing medicines with a «medical prescription only» label without requiring a doctor's prescription. Methods: We performed a cross-sectional study of 166 community pharmacies in northwest Spain. The opinions of pharmacists on the following were collected as independent variables through personal interview: a physicians' prescribing practices; b the pharmacist's qualifications to prescribe; c the responsibility of the pharmacist regarding the dispensed drugs; d the customer' qualifications for self-medication; and e the pharmacist's perception of his or her own work. The dependent variable was the pharmacist's demand for a medical prescription for 5 drugs, which in Spain require a prescription. Multiple linear regression models were constructed. Results: The response rate was 98.8%. A total of 65.9% of pharmacists reported dispensing antibiotics without a prescription. This percentage was 83.5% for nonsteroidal anti-inflammatory drugs, 46.3% for angiotensin-converting enzyme inhibitors, 13.4% for benzodiazepines, and 84.8% for oral contraceptives. Further results showed that pharmacists with a heavier workload and those who underestimated the physicians' qualifications to prescribe but overestimated their own qualifications to prescribe less frequently demanded medical prescriptions. In contrast, pharmacists who stressed the importance of their duty in rationalizing the consumption of drugs more frequently demanded medical prescriptions. Conclusion: Our results suggest that to increase the quality of dispensing: a the importance of the pharmacist's duty in controlling drug consumption should be stressed; b pharmacies' workload should be optimized; and c perceptions of physicians' prescribing practices among pharmacists should be improved.Objetivo: Evaluar la influencia de las opiniones de los farmacéuticos que no solicitan receta médica para dispensar fármacos que la

  13. Mpl expression on megakaryocytes and platelets is dispensable for thrombopoiesis but essential to prevent myeloproliferation.

    Science.gov (United States)

    Ng, Ashley P; Kauppi, Maria; Metcalf, Donald; Hyland, Craig D; Josefsson, Emma C; Lebois, Marion; Zhang, Jian-Guo; Baldwin, Tracey M; Di Rago, Ladina; Hilton, Douglas J; Alexander, Warren S

    2014-04-22

    Thrombopoietin (TPO) acting via its receptor, the cellular homologue of the myeloproliferative leukemia virus oncogene (Mpl), is the major cytokine regulator of platelet number. To precisely define the role of specific hematopoietic cells in TPO-dependent hematopoiesis, we generated mice that express the Mpl receptor normally on stem/progenitor cells but lack expression on megakaryocytes and platelets (Mpl(PF4cre/PF4cre)). Mpl(PF4cre/PF4cre) mice displayed profound megakaryocytosis and thrombocytosis with a remarkable expansion of megakaryocyte-committed and multipotential progenitor cells, the latter displaying biological responses and a gene expression signature indicative of chronic TPO overstimulation as the underlying causative mechanism, despite a normal circulating TPO level. Thus, TPO signaling in megakaryocytes is dispensable for platelet production; its key role in control of platelet number is via generation and stimulation of the bipotential megakaryocyte precursors. Nevertheless, Mpl expression on megakaryocytes and platelets is essential to prevent megakaryocytosis and myeloproliferation by restricting the amount of TPO available to stimulate the production of megakaryocytes from the progenitor cell pool.

  14. Radiological safety and GMP in the bulk batch manufacturing, formulation and dispensing of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Thulasidhasan, A.; Tiwary, Bikash; Kumar, Uma Sheri; Kale, Pooja; Tiwary, Richa; Gaurav, Ananad; Shah, B.K.; Topale, P.D.; Prabhakar, G.; Sachdev, S.S.

    2010-01-01

    Full text: Radiopharmaceutical Program of BRIT is involved in the manufacturing of ready to use radiopharmaceuticals for therapy for the last three decades. Ready to use Radiopharmaceutical products include, 131 I-Sodium iodide solution and capsules for thyroid carcinoma and metastatic lesions, 131 I MIBG injection for diagnosis and therapy of adrenal medullae tumors and their mets, 153 Sm-EDTMP injection and 32 P- Sodium orthophosphate injection for bone pain palliative treatment. BRIT's radiopharmaceutical production facility is a radioisotope laboratory classified as Type-III facility for handling radioisotopes of Group-II, Group-III and Group-IV approved by AERB. This facility meets all the radiological safety requirements as per AERB guidelines. Production of above mentioned radiopharmaceuticals is carried out in Production Plants (PP), β, γ Glove boxes (GB) and Fume hoods (FH). Typical production procedure involves bulk processing, formulation, sterilization and dispensing of doses. Production Plants (PP) are exclusively designed facilities to carry out the production in a radiologically safe manner, at the same time maintaining aseptic conditions required for injectables as per the current GMP. Each production plant has a leak tight Isolator box, made up of high quality SS which has provisions for remote handling devices like, Tongs, dispensing systems, service points for vacuum, gas, compressed air, water and electric power. This Isolator box is shielded from all sides by required amount of lead (2 inch or 4 inch), and has an access port called 'Transport Port Box' with double door transport lock and is equipped with a trolley. Two filter unit systems are fitted at the top of the plant and each unit comprises of activated Charcoal filter and HEPA filter in tandem, this in turn is connected to special exhaust meant for radioactive gases. Similarly, the designs of β, γ Glove boxes (GB) and Fume hoods (FH) also incorporate all radiological safety features

  15. Public sector refraction and spectacle dispensing in low-resource countries of the Western Pacific.

    Science.gov (United States)

    Ramke, Jacqueline; du Toit, Rènée; Palagyi, Anna; Williams, Carmel; Brian, Garry

    2008-05-01

    Given that uncorrected refractive error is a frequent cause of vision impairment, and that there is a high unmet need for spectacles, an appraisal of public sector arrangements for the correction of refractive error was conducted in eight Pacific Island countries. Mixed methods (questionnaire and semi-structured interviews) were used to collect information from eye care personnel (from Fiji, Papua New Guinea, Solomon Islands, Vanuatu, Cook Islands, Samoa, Tonga and Tuvalu) attending a regional eye health workshop in 2005. Fiji, Tonga and Vanuatu had Vision 2020 eye care plans that included refraction services, but not spectacle provision. There was wide variation in public sector spectacle dispensing services, but, except in Samoa, ready-made spectacles and a full cost recovery pricing strategy were the mainstay. There were no systems for the registration of personnel, nor guidelines for clinical or systems management. The refraction staff to population ratio varied considerably. Solomon Islands, Tuvalu and Vanuatu had the best coverage by services, either fixed or outreach. Most services had little promotional activity or community engagement. To be successful, it would seem that public sector refraction services should answer a real and perceived need, fit within prevailing policy and legislation, value, train, retain and equip employees, be well managed, be accessible and affordable, be responsive to consumers, and provide ongoing good quality outcomes. To this end, a checklist to aid the initiation and maintenance of refraction and spectacle systems in low-resource countries has been constructed.

  16. RIG-I self-oligomerization is either dispensable or very transient for signal transduction.

    Directory of Open Access Journals (Sweden)

    Jade Louber

    Full Text Available Effective host defence against viruses depends on the rapid triggering of innate immunity through the induction of a type I interferon (IFN response. To this end, microbe-associated molecular patterns are detected by dedicated receptors. Among them, the RIG-I-like receptors RIG-I and MDA5 activate IFN gene expression upon sensing viral RNA in the cytoplasm. While MDA5 forms long filaments in vitro upon activation, RIG-I is believed to oligomerize after RNA binding in order to transduce a signal. Here, we show that in vitro binding of synthetic RNA mimicking that of Mononegavirales (Ebola, rabies and measles viruses leader sequences to purified RIG-I does not induce RIG-I oligomerization. Furthermore, in cells devoid of endogenous functional RIG-I-like receptors, after activation of exogenous Flag-RIG-I by a 62-mer-5'ppp-dsRNA or by polyinosinic:polycytidylic acid, a dsRNA analogue, or by measles virus infection, anti-Flag immunoprecipitation and specific elution with Flag peptide indicated a monomeric form of RIG-I. Accordingly, when using the Gaussia Luciferase-Based Protein Complementation Assay (PCA, a more sensitive in cellula assay, no RIG-I oligomerization could be detected upon RNA stimulation. Altogether our data indicate that the need for self-oligomerization of RIG-I for signal transduction is either dispensable or very transient.

  17. Maintaining Microclimates during Nanoliter Chemical Dispensations Using Custom-Designed Source Plate Lids.

    Science.gov (United States)

    Foley, Bryan J; Drozd, Ashley M; Bollard, Mary T; Laspina, Denise; Podobedov, Nikita; Zeniou, Nicholas; Rao, Anjali S; Andi, Babak; Jackimowicz, Rick; Sweet, Robert M; McSweeney, Sean; Soares, Alexei S

    2016-02-01

    A method is described for using custom snap-on lids to protect chemicals in microtiter plates from evaporation and contamination. The lids contain apertures (diameter 1.5, 1.0, or 0.5 mm) through which the chemical building blocks can be transferred. The lid with 0.5 mm apertures was tested using a noncontact acoustic liquid handler; the 1.0 and 1.5 mm lids were tested using two tip-based liquid handlers. All of the lids reduced the rate at which solvents evaporated to room air, and greatly reduced the rate of contamination by water and oxygen from room air. In steady-state measurements, the lids reduced the rate of evaporation of methanol, 1-hexene, and water by 33% to 248%. In cycled experiments, the contamination of aqueous solvent with oxygen was reduced below detectability and the rate at which DMSO engorged atmospheric water was reduced by 81%. Our results demonstrate that the lids preserve the integrity of air-sensitive reagents during the time needed for different types of liquid handlers to perform dispensations. Controlling degradation and evaporation of chemical building blocks exposed to the atmosphere is increasingly useful as the reagent volume is reduced by advances in liquid handling technology, such as acoustic droplet ejection. © 2015 Society for Laboratory Automation and Screening.

  18. Flow and heat transfer in water based liquid film fluids dispensed with graphene nanoparticles

    Science.gov (United States)

    Zuhra, Samina; Khan, Noor Saeed; Khan, Muhammad Altaf; Islam, Saeed; Khan, Waris; Bonyah, Ebenezer

    2018-03-01

    The unsteady flow and heat transfer characteristics of electrically conducting water based thin liquid film non-Newtonian (Casson and Williamson) nanofluids dispensed with graphene nanoparticles past a stretching sheet are considered in the presence of transverse magnetic field and non-uniform heat source/sink. Embedding the graphene nanoparticles effectively amplifies the thermal conductivity of Casson and Williamson nanofluids. Ordinary differential equations together with the boundary conditions are obtained through similarity variables from the governing equations of the problem, which are solved by the HAM (Homotopy Analysis Method). The solution is expressed through graphs and illustrated which show the influences of all the parameters. The convergence of the HAM solution for the linear operators is obtained. Favorable comparison with previously published research paper is performed to show the correlation for the present work. Skin friction coefficient and Nusselt number are presented through Tables and graphs which show the validation for the achieved results demonstrating that the thin liquid films results from this study are in close agreement with the results reported in the literature. Results achieved by HAM and residual errors are evaluated numerically, given in Tables and also depicted graphically which show the accuracy of the present work.

  19. Flow and heat transfer in water based liquid film fluids dispensed with graphene nanoparticles

    Directory of Open Access Journals (Sweden)

    Samina Zuhra

    2018-03-01

    Full Text Available The unsteady flow and heat transfer characteristics of electrically conducting water based thin liquid film non-Newtonian (Casson and Williamson nanofluids dispensed with graphene nanoparticles past a stretching sheet are considered in the presence of transverse magnetic field and non-uniform heat source/sink. Embedding the graphene nanoparticles effectively amplifies the thermal conductivity of Casson and Williamson nanofluids. Ordinary differential equations together with the boundary conditions are obtained through similarity variables from the governing equations of the problem, which are solved by the HAM (Homotopy Analysis Method. The solution is expressed through graphs and illustrated which show the influences of all the parameters. The convergence of the HAM solution for the linear operators is obtained. Favorable comparison with previously published research paper is performed to show the correlation for the present work. Skin friction coefficient and Nusselt number are presented through Tables and graphs which show the validation for the achieved results demonstrating that the thin liquid films results from this study are in close agreement with the results reported in the literature. Results achieved by HAM and residual errors are evaluated numerically, given in Tables and also depicted graphically which show the accuracy of the present work. Keywords: Graphene nanoparticles, MHD, Casson and Williamson nanofluids, Stretching sheet, Skin friction coefficient, Nusselt number, Residual errors, Homotopy Analysis Method

  20. Operating experience of an automated TLD dispensing system at CORAL facility

    International Nuclear Information System (INIS)

    Ajoy, K.C.; Dhanasekaran, A.; Arun, R.; Yuvaraj, N.; Karthikeyan, D.; Dheeraj, R.; Akila, R.; Santhanam, R.; Rajagopal, V.; Kumar, Amudhu Ramesh

    2016-01-01

    Monitoring of exposures to occupational workers on individual basis is a regulatory requirement to demonstrate compliance that the dose to the workers is well within the dose limit. Over three decades for monitoring of external exposures, CaSO 4 based Thermo luminescence dosimeters (TLDs), which exhibit the required accuracy, reliability and ruggedness have been employed. TLD cards with unique identification number are loaded in plastic cassettes along with photographs are placed in wooden racks at the entry of the controlled area of the plant. However, there is always a chance that a TLD may be misplaced, used by others or there could be a deliberate act of misuse or abuse. To circumvent this it was decided to install an automated TLD dispensing system with individual TLD tracking as well as locking arrangement. CORAL reprocessing facility at IGCAR was the first to install one such system at Kalpakkam and the operating experience of the system for the last two years is brought out in this paper

  1. Characteristics of good quality pharmaceutical services common to community pharmacies and dispensing general practices.

    Science.gov (United States)

    Grey, Elisabeth; Harris, Michael; Rodham, Karen; Weiss, Marjorie C

    2016-10-01

    In the United Kingdom, pharmaceutical services can be delivered by both community pharmacies (CPs) and dispensing doctor practices (DPs). Both must adhere to minimum standards set out in NHS regulations; however, no common framework exists to guide quality improvement. Previous phases of this research had developed a set of characteristics indicative of good pharmaceutical service provision. To ask key stakeholders to confirm, and rank the importance of, a set of characteristics of good pharmaceutical service provision. A two-round Delphi-type survey was conducted in south-west England and was sent to participants representing three stakeholder groups: DPs, CPs and patients/lay members. Participants were asked to confirm, and rank, the importance of these characteristics as representing good quality pharmaceutical services. Thirty people were sent the first round survey; 22 participants completed both rounds. Median ratings for the 23 characteristics showed that all were seen to represent important aspects of pharmaceutical service provision. Participants' comments highlighted potential problems with the practicality of the characteristics. Characteristics relating to patient safety were deemed to be the most important and those relating to public health the least important. A set of 23 characteristics for providing good pharmaceutical services in CPs and DPs was developed and attained approval from a sample of stakeholders. With further testing and wider discussion, it is hoped that the characteristics will form the basis of a quality improvement tool for CPs and DPs. © 2016 Royal Pharmaceutical Society.

  2. PGC-1α is dispensable for exercise-induced mitochondrial biogenesis in skeletal muscle.

    Directory of Open Access Journals (Sweden)

    Glenn C Rowe

    Full Text Available Exercise confers numerous health benefits, many of which are thought to stem from exercise-induced mitochondrial biogenesis (EIMB in skeletal muscle. The transcriptional coactivator PGC-1α, a potent regulator of metabolism in numerous tissues, is widely believed to be required for EIMB. We show here that this is not the case. Mice engineered to lack PGC-1α specifically in skeletal muscle (Myo-PGC-1αKO mice retained intact EIMB. The exercise capacity of these mice was comparable to littermate controls. Induction of metabolic genes after 2 weeks of in-cage voluntary wheel running was intact. Electron microscopy revealed no gross abnormalities in mitochondria, and the mitochondrial biogenic response to endurance exercise was as robust in Myo-PGC-1αKO mice as in wildtype mice. The induction of enzymatic activity of the electron transport chain by exercise was likewise unperturbed in Myo-PGC-1αKO mice. These data demonstrate that PGC-1α is dispensable for exercise-induced mitochondrial biogenesis in skeletal muscle, in sharp contrast to the prevalent assumption in the field.

  3. Productive performance of Nile tilapia (Oreochromis niloticus fed at different frequencies and periods with automatic dispenser

    Directory of Open Access Journals (Sweden)

    R.M.R. Sousa

    2012-02-01

    Full Text Available The performance of Nile tilapia (Oreochromis niloticus raised in cages furnished with an automatic dispenser, supplied at different frequencies (once per hour and once every two hours and periods (daytime, nighttime and both was evaluated. Eighteen 1.0m³ cages were placed into a 2000m² pond, two meters deep with a 5% water exchange. One hundred and seventy tilapias, with initial weight of 16.0±4.9g, were dispersed into each 1m³ cage and the feed ration was adjusted every 21 days with biometry. Data was collected from March to July (autumn and winter. Significant difference to final weight (P<0.05 among treatments was observed. The increase in feeding frequency improves the productive performance of Nile tilapias in cages and permitted better management of the food. The better feed conversion rate for high feeding frequency (24 times day-1 can result in saving up to 360kg of food for each ton of fish produced, increasing the economic sustenance for tilapia culture and suggesting less environmental pollution.

  4. RNA-Interference Components Are Dispensable for Transcriptional Silencing of the Drosophila Bithorax-Complex

    KAUST Repository

    Cernilogar, Filippo M.

    2013-06-13

    Background:Beyond their role in post-transcriptional gene silencing, Dicer and Argonaute, two components of the RNA interference (RNAi) machinery, were shown to be involved in epigenetic regulation of centromeric heterochromatin and transcriptional gene silencing. In particular, RNAi mechanisms appear to play a role in repeat induced silencing and some aspects of Polycomb-mediated gene silencing. However, the functional interplay of RNAi mechanisms and Polycomb group (PcG) pathways at endogenous loci remains to be elucidated.Principal Findings:Here we show that the endogenous Dicer-2/Argonaute-2 RNAi pathway is dispensable for the PcG mediated silencing of the homeotic Bithorax Complex (BX-C). Although Dicer-2 depletion triggers mild transcriptional activation at Polycomb Response Elements (PREs), this does not induce transcriptional changes at PcG-repressed genes. Moreover, Dicer-2 is not needed to maintain global levels of methylation of lysine 27 of histone H3 and does not affect PRE-mediated higher order chromatin structures within the BX-C. Finally bioinformatic analysis, comparing published data sets of PcG targets with Argonaute-2-bound small RNAs reveals no enrichment of these small RNAs at promoter regions associated with PcG proteins.Conclusions:We conclude that the Dicer-2/Argonaute-2 RNAi pathway, despite its role in pairing sensitive gene silencing of transgenes, does not have a role in PcG dependent silencing of major homeotic gene cluster loci in Drosophila. © 2013 Cernilogar et al.

  5. Myogenin regulates exercise capacity but is dispensable for skeletal muscle regeneration in adult mdx mice.

    Directory of Open Access Journals (Sweden)

    Eric Meadows

    Full Text Available Duchenne muscular dystrophy (DMD is the most prevalent inherited childhood muscle disorder in humans. mdx mice exhibit a similar pathophysiology to the human disorder allowing for an in-depth investigation of DMD. Myogenin, a myogenic regulatory factor, is best known for its role in embryonic myogenesis, but its role in adult muscle maintenance and regeneration is still poorly understood. Here, we generated an mdx:Myog(flox/flox mouse harboring a tamoxifen-inducible Cre recombinase transgene, which was used to conditionally delete Myog during adult life. After tamoxifen treatment, three groups of mice were created to study the effects of Myog deletion: mdx:Myog(flox/flox mice (mdx, Myog(flox/flox mice (wild-type, and mdx:Myog(floxΔ/floxΔ:Cre-ER mice (mdx:Myog-deleted. mdx:Myog-deleted mice exhibited no adverse phenotype and behaved normally. When run to exhaustion, mdx:Myog-deleted mice demonstrated an enhanced capacity for exercise compared to mdx mice, running nearly as far as wild-type mice. Moreover, these mice showed the same signature characteristics of muscle regeneration as mdx mice. Unexpectedly, we found that myogenin was dispensable for muscle regeneration. Factors associated with muscle fatigue, metabolism, and proteolysis were significantly altered in mdx:Myog-deleted mice, and this might contribute to their increased exercise capacity. Our results reveal novel functions for myogenin in adult muscle and suggest that reducing Myog expression in other muscle disease models may partially restore muscle function.

  6. Evaluation of pharmacists' services for dispensing emergency contraceptive pills in Delhi, India: A mystery shopper study

    Directory of Open Access Journals (Sweden)

    Pikee Saxena

    2016-01-01

    Full Text Available Background: Although emergency contraceptive pills are available over the counter, the quality of consultation, including key areas of contraceptive counseling and prevention of sexually transmitted infections (STI, has not been well documented. Objective: To evaluate actual pharmacist services while dispensing emergency contraception through a mystery shopper technique. Material and Methods: This cross-sectional study was conducted in 81 pharmacies situated in Delhi by 4 trained mystery shoppers posed as customers over a period of 6 months. Results: None of the pharmacists asked about the time lapsed since last unprotected sexual intercourse or last menstrual period before deciding the eligibility of the customer. The majority were unclear about side effects associated with emergency contraception (78.57% or with anticipated changes in menstrual flow (78.57%; 85.71% did not know whether subsequent unprotected intercourse would be protected. Only 15.71% counseled shoppers regarding risk of STI on asking leading questions and 88.5% did not provide any contraceptive advice. Conclusion: There is a huge gap in the technical knowledge and mindset of the pharmacists when it comes to checking for the eligibility of the client and providing advice regarding use of regular contraception and barrier for protection from STI, which needs to be addressed in order to realize the full benefit of making emergency contraceptive pills available over the counter.

  7. HOMA1-IR and HOMA2-IR indexes in identifying insulin resistance and metabolic syndrome: Brazilian Metabolic Syndrome Study (BRAMS).

    Science.gov (United States)

    Geloneze, Bruno; Vasques, Ana Carolina Junqueira; Stabe, Christiane França Camargo; Pareja, José Carlos; Rosado, Lina Enriqueta Frandsen Paez de Lima; Queiroz, Elaine Cristina de; Tambascia, Marcos Antonio

    2009-03-01

    To investigate cut-off values for HOMA1-IR and HOMA2-IR to identify insulin resistance (IR) and metabolic syndrome (MS), and to assess the association of the indexes with components of the MS. Nondiabetic subjects from the Brazilian Metabolic Syndrome Study were studied (n = 1,203, 18 to 78 years). The cut-off values for IR were determined from the 90th percentile in the healthy group (n = 297) and, for MS, a ROC curve was generated for the total sample. In the healthy group, HOMA-IR indexes were associated with central obesity, triglycerides and total cholesterol (p 2.7 and HOMA2-IR > 1.8; and, for MS were: HOMA1-IR > 2.3 (sensitivity: 76.8%; specificity: 66.7%) and HOMA2-IR > 1.4 (sensitivity: 79.2%; specificity: 61.2%). The cut-off values identified for HOMA1-IR and HOMA2-IR indexes have a clinical and epidemiological application for identifying IR and MS in Westernized admixtured multi-ethnic populations.

  8. Ethanol distribution, dispensing, and use: analysis of a portion of the biomass-to-biofuels supply chain using system dynamics.

    Science.gov (United States)

    Vimmerstedt, Laura J; Bush, Brian; Peterson, Steve

    2012-01-01

    The Energy Independence and Security Act of 2007 targets use of 36 billion gallons of biofuels per year by 2022. Achieving this may require substantial changes to current transportation fuel systems for distribution, dispensing, and use in vehicles. The U.S. Department of Energy and the National Renewable Energy Laboratory designed a system dynamics approach to help focus government action by determining what supply chain changes would have the greatest potential to accelerate biofuels deployment. The National Renewable Energy Laboratory developed the Biomass Scenario Model, a system dynamics model which represents the primary system effects and dependencies in the biomass-to-biofuels supply chain. The model provides a framework for developing scenarios and conducting biofuels policy analysis. This paper focuses on the downstream portion of the supply chain-represented in the distribution logistics, dispensing station, and fuel utilization, and vehicle modules of the Biomass Scenario Model. This model initially focused on ethanol, but has since been expanded to include other biofuels. Some portions of this system are represented dynamically with major interactions and feedbacks, especially those related to a dispensing station owner's decision whether to offer ethanol fuel and a consumer's choice whether to purchase that fuel. Other portions of the system are modeled with little or no dynamics; the vehicle choices of consumers are represented as discrete scenarios. This paper explores conditions needed to sustain an ethanol fuel market and identifies implications of these findings for program and policy goals. A large, economically sustainable ethanol fuel market (or other biofuel market) requires low end-user fuel price relative to gasoline and sufficient producer payment, which are difficult to achieve simultaneously. Other requirements (different for ethanol vs. other biofuel markets) include the need for infrastructure for distribution and dispensing and

  9. Pharmacy Professionals' Dispensing Practice, Knowledge, and Attitude towards Emergency Contraceptives in Gondar Town, Northwestern Ethiopia: A Cross-Sectional Study

    OpenAIRE

    Belachew, Sewunet Admasu; Yimenu, Dawit Kumilachew; Gebresillassie, Begashaw Melaku

    2017-01-01

    Background. Pharmacy professionals, as the most available members of medical team, have an important role in educating patients about the effective and appropriate use of contraceptives. The purpose of this study was to assess pharmacy professionals’ dispensing practice, knowledge, and attitude towards emergency contraceptives use in Gondar town, northwestern Ethiopia. Methods. An institution based cross-sectional study was employed from May 14 to June 14, 2016, on 60 pharmacy professionals, ...

  10. Microbiological evaluation of hot beverages dispensed by vending machines from the Army barracks of Brigata Meccanizzata Aosta located in Messina

    OpenAIRE

    Chiara Beninati; Daniele Muscolino; Antonio Panebianco; Alessandro Giuffrida; Filippo Giarratana; Attilio Longo

    2013-01-01

    The aim of the present study was to evaluate the microbiological quality of hot beverages dispensed by vending machines (VMs). The study was carried out on 203 samples from 15 VMs located in 5 Army barracks in Messina. The samples included: water used for preparation of beverages, swab of water tank, swab of blender machine, chocolate powder, milk powder, cappuccino and chocolate drink (29 samples for each types). All samples were examined for total bacterial count (TBC), coliforms, Escherich...

  11. Ethanol Distribution, Dispensing, and Use: Analysis of a Portion of the Biomass-to-Biofuels Supply Chain Using System Dynamics

    Science.gov (United States)

    Vimmerstedt, Laura J.; Bush, Brian; Peterson, Steve

    2012-01-01

    The Energy Independence and Security Act of 2007 targets use of 36 billion gallons of biofuels per year by 2022. Achieving this may require substantial changes to current transportation fuel systems for distribution, dispensing, and use in vehicles. The U.S. Department of Energy and the National Renewable Energy Laboratory designed a system dynamics approach to help focus government action by determining what supply chain changes would have the greatest potential to accelerate biofuels deployment. The National Renewable Energy Laboratory developed the Biomass Scenario Model, a system dynamics model which represents the primary system effects and dependencies in the biomass-to-biofuels supply chain. The model provides a framework for developing scenarios and conducting biofuels policy analysis. This paper focuses on the downstream portion of the supply chain–represented in the distribution logistics, dispensing station, and fuel utilization, and vehicle modules of the Biomass Scenario Model. This model initially focused on ethanol, but has since been expanded to include other biofuels. Some portions of this system are represented dynamically with major interactions and feedbacks, especially those related to a dispensing station owner’s decision whether to offer ethanol fuel and a consumer’s choice whether to purchase that fuel. Other portions of the system are modeled with little or no dynamics; the vehicle choices of consumers are represented as discrete scenarios. This paper explores conditions needed to sustain an ethanol fuel market and identifies implications of these findings for program and policy goals. A large, economically sustainable ethanol fuel market (or other biofuel market) requires low end-user fuel price relative to gasoline and sufficient producer payment, which are difficult to achieve simultaneously. Other requirements (different for ethanol vs. other biofuel markets) include the need for infrastructure for distribution and dispensing and

  12. Distinct signalling properties of insulin receptor substrate (IRS)-1 and IRS-2 in mediating insulin/IGF-1 action

    DEFF Research Database (Denmark)

    Rabiee, Atefeh; Krüger, Marcus; Ardenkjær-Larsen, Jacob

    2018-01-01

    Insulin/IGF-1 action is driven by a complex and highly integrated signalling network. Loss-of-function studies indicate that the major insulin/IGF-1 receptor substrate (IRS) proteins, IRS-1 and IRS-2, mediate different biological functions in vitro and in vivo, suggesting specific signalling...... properties despite their high degree of homology. To identify mechanisms contributing to the differential signalling properties of IRS-1 and IRS-2 in the mediation of insulin/IGF-1 action, we performed comprehensive mass spectrometry (MS)-based phosphoproteomic profiling of brown preadipocytes from wild type......, IRS-1-/-and IRS-2-/-mice in the basal and IGF-1-stimulated states. We applied stable isotope labeling by amino acids in cell culture (SILAC) for the accurate quantitation of changes in protein phosphorylation. We found ~10% of the 6262 unique phosphorylation sites detected to be regulated by IGF-1...

  13. Selective C--C coupling of ir-ethene and ir-carbenoid radicals

    NARCIS (Netherlands)

    Dzik, W.I.; Reek, J.N.H.; de Bruin, B.

    2008-01-01

    The reactivity of the paramagnetic iridium(II) complex [IrII(ethene)(Me3tpa)]2+ (1) (Me3tpa=N,N,N-tris(6-methyl-2-pyridylmethyl) amine) towards the diazo compounds ethyl diazoacetate (EDA) and trimethylsilyldiazomethane (TMSDM) was investigated. The reaction with EDA gave rise to selective CC bond

  14. Improvenments in environmental trace analysis by GC-IR and LC-IR.

    NARCIS (Netherlands)

    Visser, T.; Vredenbregt, M.J.; Jong, A.P.J.M.; Somsen, G.W.; Hankemeier, T.; Velthorst, N.H.; Gooijer, C.; Brinkman, U.A.T.

    1997-01-01

    Research has been carried out to enlarge the potential of infrared (IR) spectrometry as a detector in gas and liquid chromatography (GC and LC). The study has been directed to applications in environmental analysis. Examples of recently obtained results are presented. The analyte detectability of

  15. Electronic structure, local magnetism, and spin-orbit effects of Ir(IV)-, Ir(V)-, and Ir(VI)-based compounds

    Energy Technology Data Exchange (ETDEWEB)

    Laguna-Marco, M. A.; Kayser, P.; Alonso, J. A.; Martínez-Lope, M. J.; van Veenendaal, M.; Choi, Y.; Haskel, D.

    2015-06-01

    Element- and orbital-selective x-ray absorption and magnetic circular dichroism measurements are carried out to probe the electronic structure and magnetism of Ir 5d electronic states in double perovskite Sr2MIrO6 (M = Mg, Ca, Sc, Ti, Ni, Fe, Zn, In) and La2NiIrO6 compounds. All the studied systems present a significant influence of spin-orbit interactions in the electronic ground state. In addition, we find that the Ir 5d local magnetic moment shows different character depending on the oxidation state despite the net magnetization being similar for all the compounds. Ir carries an orbital contribution comparable to the spin contribution for Ir4+ (5d(5)) and Ir5+ (5d(4)) oxides, whereas the orbital contribution is quenched for Ir6+ (5d(3)) samples. Incorporation of a magnetic 3d atom allows getting insight into the magnetic coupling between 5d and 3d transition metals. Together with previous susceptibility and neutron diffractionmeasurements, the results indicate that Ir carries a significant local magnetic moment even in samples without a 3d metal. The size of the (small) net magnetization of these compounds is a result of predominant antiferromagnetic interactions between local moments coupled with structural details of each perovskite structure

  16. Pharmacy Professionals' Dispensing Practice, Knowledge, and Attitude towards Emergency Contraceptives in Gondar Town, Northwestern Ethiopia: A Cross-Sectional Study.

    Science.gov (United States)

    Belachew, Sewunet Admasu; Yimenu, Dawit Kumilachew; Gebresillassie, Begashaw Melaku

    2017-01-01

    Pharmacy professionals, as the most available members of medical team, have an important role in educating patients about the effective and appropriate use of contraceptives. The purpose of this study was to assess pharmacy professionals' dispensing practice, knowledge, and attitude towards emergency contraceptives use in Gondar town, northwestern Ethiopia. An institution based cross-sectional study was employed from May 14 to June 14, 2016, on 60 pharmacy professionals, who have been working in 8 randomly selected pharmacies and 6 drug stores. The collected data was entered to and analyzed using Statistical Packages for Social Sciences (SPSS) version 20. More than half 33 (55.0%) of the participants were druggist with 5-9 years of experience. About 56 (93.3%) of the participants knew about the dosing schedule (when and how much to take) and side effects of emergency contraceptives. More than two-thirds of the participants (39, 65%) agreed that the existence of emergency contraceptives is a positive thing and considered their use is ethical (42, 63.3%). The majority of participants (51, 85%) also reported that they counsel all women when dispensing emergency contraceptive pills (ECPs). This study revealed that knowledge, attitude, and dispensing practice of emergency contraceptives are very good even though there were variations with respect to different factors. Findings suggested that additional training and proper counseling technique on emergency contraceptives will improve the service delivery.

  17. Pharmacy Professionals’ Dispensing Practice, Knowledge, and Attitude towards Emergency Contraceptives in Gondar Town, Northwestern Ethiopia: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Sewunet Admasu Belachew

    2017-01-01

    Full Text Available Background. Pharmacy professionals, as the most available members of medical team, have an important role in educating patients about the effective and appropriate use of contraceptives. The purpose of this study was to assess pharmacy professionals’ dispensing practice, knowledge, and attitude towards emergency contraceptives use in Gondar town, northwestern Ethiopia. Methods. An institution based cross-sectional study was employed from May 14 to June 14, 2016, on 60 pharmacy professionals, who have been working in 8 randomly selected pharmacies and 6 drug stores. The collected data was entered to and analyzed using Statistical Packages for Social Sciences (SPSS version 20. Result. More than half 33 (55.0% of the participants were druggist with 5–9 years of experience. About 56 (93.3% of the participants knew about the dosing schedule (when and how much to take and side effects of emergency contraceptives. More than two-thirds of the participants (39, 65% agreed that the existence of emergency contraceptives is a positive thing and considered their use is ethical (42, 63.3%. The majority of participants (51, 85% also reported that they counsel all women when dispensing emergency contraceptive pills (ECPs. Conclusion. This study revealed that knowledge, attitude, and dispensing practice of emergency contraceptives are very good even though there were variations with respect to different factors. Findings suggested that additional training and proper counseling technique on emergency contraceptives will improve the service delivery.

  18. Inkjet metrology: high-accuracy mass measurements of microdroplets produced by a drop-on-demand dispenser.

    Science.gov (United States)

    Verkouteren, R Michael; Verkouteren, Jennifer R

    2009-10-15

    We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (u(c)) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 microg (1490 droplets) with u(c) = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies.

  19. Cell dispensing in low-volume range with the immediate drop-on-demand technology (I-DOT).

    Science.gov (United States)

    Schober, Lena; Büttner, Evy; Laske, Christopher; Traube, Andrea; Brode, Tobias; Traube, Andreas Florian; Bauernhansl, Thomas

    2015-04-01

    Handling and dosing of cells comprise the most critical step in the microfabrication of cell-based assay systems for screening and toxicity testing. Therefore, the immediate drop-on-demand technology (I-DOT) was developed to provide a flexible noncontact liquid handling system enabling dispensing of cells and liquid without the risk of cross-contamination down to a precise volume in the nanoliter range. Liquid is dispensed from a source plate within nozzles at the bottom by a short compressed air pulse that is given through a quick release valve into the well, thus exceeding the capillary pressure in the nozzle. Droplets of a defined volume can be spotted directly onto microplates or other cell culture devices. We present a study on the performance and biological impact of this technology by applying the cell line MCF-7, human fibroblasts, and human mesenchymal stem cells (hMSCs). For all cell types tested, viability after dispensing is comparable to the control and exhibits similar proliferation rates in the absence of apoptotic cells, and the differentiation potential of hMSCs is not impaired. The immediate drop-on-demand technology enables accurate cell dosage and offers promising potential for single-cell applications. © 2014 Society for Laboratory Automation and Screening.

  20. The Introduction of an Undergraduate Interventional Radiology (IR) Curriculum: Impact on Medical Student Knowledge and Interest in IR

    International Nuclear Information System (INIS)

    Shaikh, M.; Shaygi, B.; Asadi, H.; Thanaratnam, P.; Pennycooke, K.; Mirza, M.; Lee, M.

    2016-01-01

    IntroductionInterventional radiology (IR) plays a vital role in modern medicine, with increasing demand for services, but with a shortage of experienced interventionalists. The aim of this study was to determine the impact of a recently introduced IR curriculum on perception, knowledge, and interest of medical students regarding various aspects of IR.MethodsIn 2014, an anonymous web-based questionnaire was sent to 309 4th year medical students in a single institution within an EU country, both before and after delivery of a 10-h IR teaching curriculum.ResultsSeventy-six percent (236/309) of the respondents participated in the pre-IR module survey, while 50 % (157/309) responded to the post-IR module survey. While 62 % (147/236) of the respondents reported poor or no knowledge of IR compared to other medical disciplines in the pre-IR module survey, this decreased to 17 % (27/157) in the post-IR module survey. The correct responses regarding knowledge of selected IR procedures improved from 70 to 94 % for venous access, 78 to 99 % for uterine fibroid embolization, 75 to 97 % for GI bleeding embolization, 60 to 92 % for trauma embolization, 71 to 92 % for tumor ablation, and 81 to 94 % for angioplasty and stenting in peripheral arterial disease. With regard to knowledge of IR clinical roles, responses improved from 42 to 59 % for outpatient clinic review of patients and having inpatient beds, 63–76 % for direct patient consultation, and 43–60 % for having regular ward rounds. The number of students who would consider a career in IR increased from 60 to 73 %.ConclusionDelivering an undergraduate IR curriculum increased the knowledge and understanding of various aspects of IR and also the general enthusiasm for pursuing this specialty as a future career choice.

  1. The Introduction of an Undergraduate Interventional Radiology (IR) Curriculum: Impact on Medical Student Knowledge and Interest in IR

    Energy Technology Data Exchange (ETDEWEB)

    Shaikh, M. [Bradford Royal Infirmary, Department of Radiology, Bradford Teaching Hospital Foundation Trust (United Kingdom); Shaygi, B. [Royal Devon and Exeter Hospital, Interventional Radiology Department (United Kingdom); Asadi, H., E-mail: asadi.hamed@gmail.com; Thanaratnam, P.; Pennycooke, K.; Mirza, M.; Lee, M., E-mail: mlee@rcsi.ie [Beaumont Hospital, Interventional Radiology Service, Department of Radiology (Ireland)

    2016-04-15

    IntroductionInterventional radiology (IR) plays a vital role in modern medicine, with increasing demand for services, but with a shortage of experienced interventionalists. The aim of this study was to determine the impact of a recently introduced IR curriculum on perception, knowledge, and interest of medical students regarding various aspects of IR.MethodsIn 2014, an anonymous web-based questionnaire was sent to 309 4th year medical students in a single institution within an EU country, both before and after delivery of a 10-h IR teaching curriculum.ResultsSeventy-six percent (236/309) of the respondents participated in the pre-IR module survey, while 50 % (157/309) responded to the post-IR module survey. While 62 % (147/236) of the respondents reported poor or no knowledge of IR compared to other medical disciplines in the pre-IR module survey, this decreased to 17 % (27/157) in the post-IR module survey. The correct responses regarding knowledge of selected IR procedures improved from 70 to 94 % for venous access, 78 to 99 % for uterine fibroid embolization, 75 to 97 % for GI bleeding embolization, 60 to 92 % for trauma embolization, 71 to 92 % for tumor ablation, and 81 to 94 % for angioplasty and stenting in peripheral arterial disease. With regard to knowledge of IR clinical roles, responses improved from 42 to 59 % for outpatient clinic review of patients and having inpatient beds, 63–76 % for direct patient consultation, and 43–60 % for having regular ward rounds. The number of students who would consider a career in IR increased from 60 to 73 %.ConclusionDelivering an undergraduate IR curriculum increased the knowledge and understanding of various aspects of IR and also the general enthusiasm for pursuing this specialty as a future career choice.

  2. IR-360 nuclear power plant safety functions and component classification

    Energy Technology Data Exchange (ETDEWEB)

    Yousefpour, F., E-mail: fyousefpour@snira.co [Management of Nuclear Power Plant Construction Company (MASNA) (Iran, Islamic Republic of); Shokri, F.; Soltani, H. [Management of Nuclear Power Plant Construction Company (MASNA) (Iran, Islamic Republic of)

    2010-10-15

    The IR-360 nuclear power plant as a 2-loop PWR of 360 MWe power generation capacity is under design in MASNA Company. For design of the IR-360 structures, systems and components (SSCs), the codes and standards and their design requirements must be determined. It is a prerequisite to classify the IR-360 safety functions and safety grade of structures, systems and components correctly for selecting and adopting the suitable design codes and standards. This paper refers to the IAEA nuclear safety codes and standards as well as USNRC standard system to determine the IR-360 safety functions and to formulate the principles of the IR-360 component classification in accordance with the safety philosophy and feature of the IR-360. By implementation of defined classification procedures for the IR-360 SSCs, the appropriate design codes and standards are specified. The requirements of specific codes and standards are used in design process of IR-360 SSCs by design engineers of MASNA Company. In this paper, individual determination of the IR-360 safety functions and definition of the classification procedures and roles are presented. Implementation of this work which is described with example ensures the safety and reliability of the IR-360 nuclear power plant.

  3. IR-360 nuclear power plant safety functions and component classification

    International Nuclear Information System (INIS)

    Yousefpour, F.; Shokri, F.; Soltani, H.

    2010-01-01

    The IR-360 nuclear power plant as a 2-loop PWR of 360 MWe power generation capacity is under design in MASNA Company. For design of the IR-360 structures, systems and components (SSCs), the codes and standards and their design requirements must be determined. It is a prerequisite to classify the IR-360 safety functions and safety grade of structures, systems and components correctly for selecting and adopting the suitable design codes and standards. This paper refers to the IAEA nuclear safety codes and standards as well as USNRC standard system to determine the IR-360 safety functions and to formulate the principles of the IR-360 component classification in accordance with the safety philosophy and feature of the IR-360. By implementation of defined classification procedures for the IR-360 SSCs, the appropriate design codes and standards are specified. The requirements of specific codes and standards are used in design process of IR-360 SSCs by design engineers of MASNA Company. In this paper, individual determination of the IR-360 safety functions and definition of the classification procedures and roles are presented. Implementation of this work which is described with example ensures the safety and reliability of the IR-360 nuclear power plant.

  4. ELECTROSPUN MESOFIBERS, A NOVEL BIODEGRADABLE PHEROMONE DISPENSER TECHNOLOGY, ARE COMBINED WITH MECHANICAL DEPLOYMENT FOR EFFICIENT IPM OF LOBESIA BOTRANA IN VINEYARDS.

    Science.gov (United States)

    Hummel, Hans E; Langner, S S; Breuer, M

    2015-01-01

    Behaviour modifying pheromones are well known agents for disrupting mating communication of pest insects. For optimal activity, they must be dispensed in time and space at a quantitatively measurable, predetermined release rate covering the flight period of the target species. Pheromones appeal to environmentally conscientious entomologists for their biodegradability, non-toxicity and ecological compatibility. In attempts of combining the virtues of pheromones, suitable slow release dispensers, and their mechanical deployment, an ecologically sensible, reasonably priced and patented procedure was developed and tested with the vineyard pest Lobesia botrana (Lep.: Tortricidae). It is characterized by (1) Electrospun mesofibers with diameters ranging from 0.6 to 3.5 micrometres, containing disruptants and dispensing it by slow release diffusion into the crop, (2) simultaneous application of the fully biodegradable combination of pheromone with Ecoflex polyester mesofiber, (3) combination of mechanical deployment by multi-purpose cultivators of the prefabricated pheromone dispensers with other simultaneous cultivation measures, and thus further reducing labour time and treatment costs. The dispensers are biodegradable within half a year without leaving any objectionable residues. In the standard eco-toxicology tests pheromone dispensers are harmless to non-target organisms. The disruptive effect of one treatment lasts for seven weeks which covers well one of several flight periods of L. botrana.

  5. Factors affecting patients' knowledge about dispensed medicines: A Qualitative study of healthcare professionals and patients in Pakistan.

    Science.gov (United States)

    Saqib, Anum; Atif, Muhammad; Ikram, Raazeyah; Riaz, Fatima; Abubakar, Muhammad; Scahill, Shane

    2018-01-01

    Patients' knowledge about their prescribed medicines is one of the most important antecedents of successful therapy. Poor knowledge about medicines can lead to serious consequences such as non-adherence and misunderstanding of the significance of adverse events. The objective of this study is to understand the factors that are responsible for a patients' lack of knowledge regarding their medicines, by taking the perspective of the patient as well as that of healthcare professionals. Much of the work in this area has been undertaken in the setting of developed or semi-developed countries, and there is a scarcity of information from developing nations such as Pakistan. This was a large qualitative study set in the hospital outpatient environment in a teaching hospital in the Punjab province of Pakistan. Data were collected from dialogue with patients (n = 19) and healthcare providers (n = 16) i.e., doctors and dispensers (where a dispenser is a person who merely dispenses medicines; i.e. is not a pharmacist) through in-depth semi-structured interviews. Patients having limited knowledge about their dispensed medicines were assessed using a checklist. The healthcare providers were recruited through a convenience sampling strategy, based on their availability and willingness to participate in the study. Based on the objectives of the study, a pilot tested interview protocol was developed, and used to conduct the interviews. The sample size was controlled by using saturation point criteria. All interviews were audio recorded and transcribed verbatim. The data were analyzed to draw conclusions using inductive thematic content analysis. The analysis of data yielded 31 categories (patients = 19, healthcare professionals = 12), 10 subthemes and three themes. The major themes were healthcare professional-related factors, patient-related factors and system-related factors. The health professional related subthemes included: behaviour and attitude and professional liabilities

  6. [Food and beverages available in automatic food dispensers in health care facilities of the Portugal North Health Region].

    Science.gov (United States)

    Rodrigues, Filipa Gomes; Ramos, Elisabete; Freitas, Mário; Neto, Maria

    2010-01-01

    Patients and health staff frequently need to stay in health care facilities for quite a long time. Therefore, it's necessary to create the conditions that allow the ingestion of food during those periods, namely through the existence of automatic food dispensers. However, the available food and beverages might not always be compatible with a healthy diet. The aim of this work was to evaluate if the food and beverages available in automatic food dispensers in public Ambulatory Care Facilities (ACF) and Hospitals of the Portugal North Health Region were contributing to a healthy diet, during the year of 2007. A questionnaire was elaborated and sent to the Coordinators of the Health Sub-Regions and to the Hospital Administrators. The questionnaire requested information about the existence of automatic food dispensers in the several departments of each health care facility, as well as which food and beverages were available and most sold. Afterwards, the pre-processing of the results involved the classification of the food and beverages in three categories: recommended, sometimes recommended and not recommended. The questionnaire reply ratio was 71% in ACF and 83% in Hospitals. Automatic food dispensers were available in all the Hospitals and 86.5% of ACF. It wasn't possible to acquire food in 37% of the health facility departments. These departments were all located in ACF. The more frequently available beverages in departments with automatic food dispensers were coffee, still water, tea, juices and nectars and soft drinks. Still water, coffee, yogurt, juices and nectars and soft drinks were reported as the most sold. The more frequently avaliable food items were chocolate, recommended cookies, not recommended cakes, recommended sandwiches and sometimes recommended croissants. The food items reported as being the most sold were recommended sandwiches, chocolate, recommended cookies, sometimes recommended croissants and not recommended cookies. The beverages in the

  7. Evaluating the Impact of Drug Dispensing Systems on the Safety and Efficiency in a Singapore Outpatient Pharmacy

    Directory of Open Access Journals (Sweden)

    Peter Ong Yong Sheng

    2014-01-01

    Full Text Available Purpose: Automation of pharmacy workflow can reduce medication errors as well as improve efficiency of the medication picking, packing and labeling process. Since September 2012, two drug dispensing systems (DDS began operations in the Singapore General Hospital Specialist Outpatient Clinic Pharmacy. This study sought to evaluate the impact of the DDS on safety and efficiency in the pharmacy. Methods: The primary outcome was the rate of prevented dispensing incidents contributed by DDS or manual picking of medications defined as the number of prevented dispensing incidents per 1000 medications picked. The secondary outcome was the productivity of each full time equivalent (FTE when assigned to either the DDS or manual picking stations. Data pertaining to the primary and secondary outcomes between January and December 2013 were collected and analyzed. The rate of prevented dispensing incidents was expressed in median (interquartile range and compared using Mann-Whitney U test. Other continuous variables were expressed in mean ± standard deviation and compared using independent samples t-test. Results: An average of 59494 medications was picked every month in the pharmacy. DDS accounted for 21.1 percent while manual picking accounted for 78.9 percent of all the medications picked. The median rate of prevented dispensing incidents per month committed by manual picking (2.73 was significantly higher than the DDS (0.00. DDS had greater productivity with each FTE in the DDS having an average of 6175 picks per month which was significantly higher than each FTE in the manual picking stations which had an average of 4867 picks per month. Conclusion: Installation of DDS in an outpatient pharmacy improved safety of the pharmacy workflow by automating the medication picking, packing and labeling process and minimizing human errors. Efficiency of the medication picking, packing and labeling process was also improved by the DDS as there were continuous

  8. Use of standardised patients to assess antibiotic dispensing for tuberculosis by pharmacies in urban India: a cross-sectional study.

    Science.gov (United States)

    Satyanarayana, Srinath; Kwan, Ada; Daniels, Benjamin; Subbaraman, Ramnath; McDowell, Andrew; Bergkvist, Sofi; Das, Ranendra K; Das, Veena; Das, Jishnu; Pai, Madhukar

    2016-11-01

    India's total antibiotic use is the highest of any country. Patients often receive prescription-only drugs directly from pharmacies. Here we aimed to assess the medical advice and drug dispensing practices of pharmacies for standardised patients with presumed and confirmed tuberculosis in India. In this cross-sectional study in the three Indian cities Delhi, Mumbai, and Patna, we developed two standardised patient cases: first, a patient presenting with 2-3 weeks of pulmonary tuberculosis symptoms (Case 1); and second, a patient with microbiologically confirmed pulmonary tuberculosis (Case 2). Standardised patients were scheduled to present each case once to sampled pharmacies. We defined ideal management for both cases a priori as referral to a health-care provider without dispensing antibiotics or steroids or both. Between April 1, 2014, and Nov 29, 2015, we sampled 622 pharmacies in Delhi, Mumbai, and Patna. Standardised patients completed 1200 (96%) of 1244 interactions. We recorded ideal management (defined as referrals without the use of antibiotics or steroids) in 80 (13%) of 599 Case 1 interactions (95% CI 11-16) and 372 (62%) of 601 Case 2 interactions (95% CI 58-66). Antibiotic use was significantly lower in Case 2 interactions (98 [16%] of 601, 95% CI 13-19) than in Case 1 (221 [37%] of 599, 95% CI 33-41). First-line anti-tuberculosis drugs were not dispensed in any city. The differences in antibiotic or steroid use and number of medicines dispensed between Case 1 and Case 2 were almost entirely attributable to the difference in referral behaviour. Only some urban Indian pharmacies correctly managed patients with presumed tuberculosis, but most correctly managed a case of confirmed tuberculosis. No pharmacy dispensed anti-tuberculosis drugs for either case. Absence of a confirmed diagnosis is a key driver of antibiotic misuse and could inform antimicrobial stewardship interventions. Grand Challenges Canada, Bill & Melinda Gates Foundation, Knowledge for

  9. Reading handprinted addresses on IRS tax forms

    Science.gov (United States)

    Ramanaprasad, Vemulapati; Shin, Yong-Chul; Srihari, Sargur N.

    1996-03-01

    The hand-printed address recognition system described in this paper is a part of the Name and Address Block Reader (NABR) system developed by the Center of Excellence for Document Analysis and Recognition (CEDAR). NABR is currently being used by the IRS to read address blocks (hand-print as well as machine-print) on fifteen different tax forms. Although machine- print address reading was relatively straightforward, hand-print address recognition has posed some special challenges due to demands on processing speed (with an expected throughput of 8450 forms/hour) and recognition accuracy. We discuss various subsystems involved in hand- printed address recognition, including word segmentation, word recognition, digit segmentation, and digit recognition. We also describe control strategies used to make effective use of these subsystems to maximize recognition accuracy. We present system performance on 931 address blocks in recognizing various fields, such as city, state, ZIP Code, street number and name, and personal names.

  10. Multichannel Dynamic Fourier-Transform IR Spectrometer

    Science.gov (United States)

    Balashov, A. A.; Vaguine, V. A.; Golyak, Il. S.; Morozov, A. N.; Khorokhorin, A. I.

    2017-09-01

    A design of a multichannel continuous scan Fourier-transform IR spectrometer for simultaneous recording and analysis of the spectral characteristics of several objects is proposed. For implementing the design, a multi-probe fiber is used, constructed from several optical fibers connected into a single optical connector and attached at the output of the interferometer. The Fourier-transform spectrometer is used as a signal modulator. Each fiber is individually mated with an investigated sample and a dedicated radiation detector. For the developed system, the radiation intensity of the spectrometer is calculated from the condition of the minimum spectral resolution and parameters of the optical fibers. Using the proposed design, emission spectra of a gas-discharge neon lamp have been recorded using a single fiber 1 mm in diameter with a numerical aperture NA = 0.22.

  11. Camouflage in thermal IR: spectral design

    Science.gov (United States)

    Pohl, Anna; Fagerström, Jan; Kariis, Hans; Lindell, Roland; Hallberg, Tomas; Högström, Herman

    2016-10-01

    In this work a spectral designed coating from SPECTROGON is evaluated. Spectral design in this case means that the coating has a reflectivity equal to one at 3-5 and 8-12 microns were sensors operate and a much lower reflectivity in the other wave length regions. Three boxes are evaluated: one metallic, one black-body and one with a spectral designed surface, all with a 15 W radiator inside the box. It is shown that the box with the spectral designed surface can combine the two good characteristics of the other boxes: low signature from the metallic box and reasonable inside temperature from the black-body box. The measurements were verified with calculations using RadThermIR.

  12. Studies of IR-screening smoke clouds

    Energy Technology Data Exchange (ETDEWEB)

    Cudzilo, S. [Military Univ. of Technology, Warsaw (Poland)

    2001-02-01

    This paper contains some results of research on the IR-screening capability of smoke clouds generated during the combustion process of varied pyrotechnic formulations. The smoke compositions were made from some oxygen or oxygen-free mixtures containing metal and chloroorganic compounds or mixtures based on red phosphorus. The camouflage effectiveness of clouds generated by these formulations was investigated under laboratory conditions with an infrared camera. The technique employed enables determination of radiant temperature distributions in a smoke cloud treated as an energy equivalent of a grey body emission. The results of the analysis of thermographs from the camera were the basis on which the mixtures producing screens of the highest countermeasure for thermal imaging systems have been chosen. (orig.)

  13. Development of Cytoplasmic Male Sterile IR24 and IR64 Using CW-CMS/Rf17 System.

    Science.gov (United States)

    Toriyama, Kinya; Kazama, Tomohiko

    2016-12-01

    A wild-abortive-type (WA) cytoplasmic male sterility (CMS) has been almost exclusively used for breeding three-line hybrid rice. Many indica cultivars are known to carry restorer genes for WA-CMS lines and cannot be used as maintainer lines. Especially elite indica cultivars IR24 and IR64 are known to be restorer lines for WA-CMS lines, and are used as male parents for hybrid seed production. If we develop CMS IR24 and CMS IR64, the combination of F1 pairs in hybrid rice breeding programs will be greatly broadened. For production of CMS lines and restorer lines of IR24 and IR64, we employed Chinese wild rice (CW)-type CMS/Restorer of fertility 17 (Rf17) system, in which fertility is restored by a single nuclear gene, Rf17. Successive backcrossing and marker-assisted selection of Rf17 succeeded to produce completely male sterile CMS lines and fully restored restorer lines of IR24 and IR64. CW-cytoplasm did not affect agronomic characteristics. Since IR64 is one of the most popular mega-varieties and used for breeding of many modern varieties, the CW-CMS line of IR64 will be useful for hybrid rice breeding.

  14. Novel cross-talk between IGF-IR and DDR1 regulates IGF-IR trafficking, signaling and biological responses

    Science.gov (United States)

    Sacco, Antonella; Morcavallo, Alaide; Vella, Veronica; Voci, Concetta; Spatuzza, Michela; Xu, Shi-Qiong; Iozzo, Renato V.; Vigneri, Riccardo; Morrione, Andrea; Belfiore, Antonino

    2015-01-01

    The insulin-like growth factor-I receptor (IGF-IR), plays a key role in regulating mammalian development and growth, and is frequently deregulated in cancer contributing to tumor initiation and progression. Discoidin domain receptor 1 (DDR1), a collagen receptor tyrosine-kinase, is as well frequently overexpressed in cancer and implicated in cancer progression. Thus, we investigated whether a functional cross-talk between the IGF-IR and DDR1 exists and plays any role in cancer progression. Using human breast cancer cells we found that DDR1 constitutively associated with the IGF-IR. However, this interaction was enhanced by IGF-I stimulation, which promoted rapid DDR1 tyrosine-phosphorylation and co-internalization with the IGF-IR. Significantly, DDR1 was critical for IGF-IR endocytosis and trafficking into early endosomes, IGF-IR protein expression and IGF-I intracellular signaling and biological effects, including cell proliferation, migration and colony formation. These biological responses were inhibited by DDR1 silencing and enhanced by DDR1 overexpression. Experiments in mouse fibroblasts co-transfected with the human IGF-IR and DDR1 gave similar results and indicated that, in the absence of IGF-IR, collagen-dependent phosphorylation of DDR1 is impaired. These results demonstrate a critical role of DDR1 in the regulation of IGF-IR action, and identify DDR1 as a novel important target for breast cancers that overexpress IGF-IR. PMID:25840417

  15. Inhibition of PTP1B Restores IRS1-Mediated Hepatic Insulin Signaling in IRS2-Deficient Mice

    Science.gov (United States)

    González-Rodríguez, Águeda; Gutierrez, Jose A. Mas; Sanz-González, Silvia; Ros, Manuel; Burks, Deborah J.; Valverde, Ángela M.

    2010-01-01

    OBJECTIVE Mice with complete deletion of insulin receptor substrate 2 (IRS2) develop hyperglycemia, impaired hepatic insulin signaling, and elevated gluconeogenesis, whereas mice deficient for protein tyrosine phosphatase (PTP)1B display an opposing hepatic phenotype characterized by increased sensitivity to insulin. To define the relationship between these two signaling pathways in the regulation of liver metabolism, we used genetic and pharmacological approaches to study the effects of inhibiting PTP1B on hepatic insulin signaling and expression of gluconeogenic enzymes in IRS2−/− mice. RESEARCH DESIGN AND METHODS We analyzed glucose homeostasis and insulin signaling in liver and isolated hepatocytes from IRS2−/− and IRS2−/−/PTP1B−/− mice. Additionally, hepatic insulin signaling was assessed in control and IRS2−/− mice treated with resveratrol, an antioxidant present in red wine. RESULTS In livers of hyperglycemic IRS2−/− mice, the expression levels of PTP1B and its association with the insulin receptor (IR) were increased. The absence of PTP1B in the double-mutant mice restored hepatic IRS1-mediated phosphatidylinositol (PI) 3-kinase/Akt/Foxo1 signaling. Moreover, resveratrol treatment of hyperglycemic IRS2−/− mice decreased hepatic PTP1B mRNA and inhibited PTP1B activity, thereby restoring IRS1-mediated PI 3-kinase/Akt/Foxo1 signaling and peripheral insulin sensitivity. CONCLUSIONS By regulating the phosphorylation state of IR, PTB1B determines sensitivity to insulin in liver and exerts a unique role in the interplay between IRS1 and IRS2 in the modulation of hepatic insulin action. PMID:20028942

  16. Study on IR Properties of Reduced Graphene Oxide

    Science.gov (United States)

    Ma, Deyue; Li, Xiaoxia; Guo, Yuxiang; Zeng, Yurun

    2018-01-01

    Firstly, the reduced graphene oxide was prepared by modified hummer method and characterized. Then, the complex refractive index of reduced graphene oxide in IR band was tested and its IR absorption and radiation properties were researched by correlated calculation. The results show that reduced graphene oxide prepared by hummer method are multilayered graphene with defects and functional groups on its surface. Its absorption in near and far IR bands is strong, but it’s weaker in middle IR band. At the IR atmosphere Window, its normal spectral emissivity decreases with wavelength increasing, and its total normal spectral emissivity in 3 ∼ 5μm and 8 ∼ 14μm are 0.75 and 0.625, respectively. Therefore, reduced graphene oxide can be used as IR absorption and coating materials and have a great potential in microwave and infrared compatible materials.

  17. Endurance test on IR rig for RI production

    International Nuclear Information System (INIS)

    Chung, Heung June; Youn, Y. J.; Han, H. S.; Hong, S. B.; Cho, Y. G.; Ryu, J. S.

    2000-12-01

    This report presents the pressure drop, vibration and endurance test results for IR rig for RI production which were desigened and fabricated by KAERI. From the pressure drop test results, it is noted that the flow rate through the IR rig corresponding to the pressure drop of 200 kPa is measured to be about 3.12 kg/sec. Vibration frequency for the IR rig ranges from 13 to 17 Hz. RMS(Root Mean Square) displacement for the IR rig is less than 30 μm, and the maximum displacement is less than 110μm. These experimental results show that the design criteria of IR rig meet the HANARO limit conditions. Endurance test results show that the appreciable fretting wear for the IR rig does not occur, however tiny trace of wear between contact points is observed

  18. Future development of IR thermovision weather satellite equipment

    Science.gov (United States)

    Listratov, A. V.

    1974-01-01

    The self radiation of the surface being viewed is used for image synthesis in IR thermovision equipment. The installation of such equipment aboard weather satellites makes it possible to obtain cloud cover pictures of the earth's surface in a complete orbit, regardless of the illumination conditions, and also provides quantitative information on the underlying surface temperature and cloud top height. Such equipment is used successfully aboard the Soviet satellites of the Meteor system, and experimentally on the American satellites of the Nimbus series. With regard to surface resolution, the present-day IR weather satellite equipment is inferior to the television equipment. This is due primarily to the comparatively low detectivity of the IR detectors used. While IR equipment has several fundamental advantages in comparison with the conventional television equipment, the problem arises of determining the possibility for future development of weather satellite IR thermovision equipment. Criteria are examined for evaluating the quality of IR.

  19. Pheromone dispensers, including organic polymer fibers, described in the crop protection literature: comparison of their innovation potential.

    Science.gov (United States)

    Hummel, Hans E; Langner, S S; Eisinger, M-T

    2013-01-01

    Pheromone dispensers, although known in a variety of different designs, are one of the few remaining technical bottlenecks along the way to a sustainable pheromone based strategy in integrated pest management (IPM). Mating disruption with synthetic pheromones is a viable pest management approach. Suitable pheromone dispensers for these mating disruption schemes, however, are lagging behind the general availability of pheromones. Specifically, there is a need for matching the properties of the synthetic pheromones, the release rates suitable for certain insect species, and the environmental requirements of specific crop management. The "ideal" dispenser should release pheromones at a constant but pre-adjustable rate, should be mechanically applicable, completely biodegradable and thus save the costs for recovering spent dispensers. These should be made from renewable, cheap organic material, be economically inexpensive, and be toxicologically and eco-toxicologically inert to provide satisfactory solutions for the needs of practicing growers. In favourable cases, they will be economically competitive with conventional pesticide treatments and by far superior in terms of environmental and eco-toxicological suitability. In the course of the last 40 years, mating disruption, a non-toxicological approach, provided proof for its potential in dozens of pest insects of various orders and families. Applications for IPM in many countries of the industrialized and developing world have been reported. While some dispensers have reached wide circulation, only few of the key performing parameters fit the above requirements ideally and must be approximated with some sacrifice in performance. A fair comparison of the innovation potential of currently available pheromone dispensers is attempted. The authors advance here the use of innovative electrospun organic fibers with dimensions in the "meso" (high nano- to low micrometer) region. Due to their unique multitude of adjustable

  20. IR sensor for monitoring of burner flame; IR sensor foer oevervakning av braennarflamma

    Energy Technology Data Exchange (ETDEWEB)

    Svanberg, Marcus; Funkquist, Jonas; Clausen, Soennik; Wetterstroem, Jonas

    2007-12-15

    To obtain a smooth operation of the coal-fired power plants many power plant managers have installed online mass flow measurement of coal to all burners. This signal is used to monitor the coal mass flow to the individual burner and match it with appropriate amount of air and also to monitor the distribution of coal between the burners. The online mass flow measurement system is very expensive (approximately 150 kEUR for ten burners) and is not beneficial for smaller plants. The accuracy of the measurement and the sample frequency are also questionable. The idea in this project has been to evaluate a cheaper system that can present the same information and may also provide better accuracy and faster sample frequency. The infrared sensor is a cheap narrow banded light emission sensor that can be placed in a water cooed probe. The sensor was directed at the burner flame and the emitted light was monitored. Through calibration the mass flow of coal can be presented. Two measurement campaigns were performed. Both campaigns were carried out in Nordjyllandsverket in Denmark even though the second campaign was planned to be in Uppsala. Due to severe problems in the Uppsala plant the campaign was moved to Nordjyllandsverket. The pre-requisites for the test plant were that online measurement of coal flow was installed. In Nordjyllandsverket 4 out of 16 burners have the mass flow measurement installed. Risoe Laboratories has vast experiences in the IR technology and they provided the IR sensing equipment. One IR sensor was placed in the flame guard position just behind the flame directed towards the ignition zone. A second sensor was placed at the boiler wall directed towards the flame. The boiler wall position did not give any results and the location was not used during the second campaign. The flame-guard-positioned-sensor- signal was thoroughly evaluated and the results show that there is a clear correlation between the coal mass flow and the IR sensor signal. Tests were

  1. New Ir Bis-Carbonyl Precursor for Water Oxidation Catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Daria L. [Department of Chemistry, Yale University, 225; Beltrán-Suito, Rodrigo [Department of Chemistry, Yale University, 225; Thomsen, Julianne M. [Department of Chemistry, Yale University, 225; Hashmi, Sara M. [Department of Chemical and Environmental; Materna, Kelly L. [Department of Chemistry, Yale University, 225; Sheehan, Stafford W. [Catalytic Innovations LLC, 70 Crandall; Mercado, Brandon Q. [Department of Chemistry, Yale University, 225; Brudvig, Gary W. [Department of Chemistry, Yale University, 225; Crabtree, Robert H. [Department of Chemistry, Yale University, 225

    2016-02-05

    This paper introduces IrI(CO)2(pyalc) (pyalc = (2-pyridyl)-2-propanoate) as an atom-efficient precursor for Ir-based homogeneous oxidation catalysis. This compound was chosen to simplify analysis of the water oxidation catalyst species formed by the previously reported Cp*IrIII(pyalc)OH water oxidation precatalyst. Here, we present a comparative study on the chemical and catalytic properties of these two precursors. Previous studies show that oxidative activation of Cp*Ir-based precursors with NaIO4 results in formation of a blue IrIV species. This activation is concomitant with the loss of the placeholder Cp* ligand which oxidatively degrades to form acetic acid, iodate, and other obligatory byproducts. The activation process requires substantial amounts of primary oxidant, and the degradation products complicate analysis of the resulting IrIV species. The species formed from oxidation of the Ir(CO)2(pyalc) precursor, on the other hand, lacks these degradation products (the CO ligands are easily lost upon oxidation) which allows for more detailed examination of the resulting Ir(pyalc) active species both catalytically and spectroscopically, although complete structural analysis is still elusive. Once Ir(CO)2(pyalc) is activated, the system requires acetic acid or acetate to prevent the formation of nanoparticles. Investigation of the activated bis-carbonyl complex also suggests several Ir(pyalc) isomers may exist in solution. By 1H NMR, activated Ir(CO)2(pyalc) has fewer isomers than activated Cp*Ir complexes, allowing for advanced characterization. Future research in this direction is expected to contribute to a better structural understanding of the active species. A diol crystallization agent was needed for the structure determination of 3.

  2. Room temperature mid-IR single photon spectral imaging

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2012-01-01

    Spectral imaging and detection of mid-infrared (mid-IR) wavelengths are emerging as an enabling technology of great technical and scientific interest; primarily because important chemical compounds display unique and strong mid-IR spectral fingerprints revealing valuable chemical information. Whi...... 20 % for polarized incoherent light at 3 \\mum. The proposed method is relevant for existing and new mid-IR applications like gas analysis and medical diagnostics....

  3. Medication Incidents Related to Automated Dose Dispensing in Community Pharmacies and Hospitals - A Reporting System Study

    Science.gov (United States)

    Cheung, Ka-Chun; van den Bemt, Patricia M. L. A.; Bouvy, Marcel L.; Wensing, Michel; De Smet, Peter A. G. M.

    2014-01-01

    Introduction Automated dose dispensing (ADD) is being introduced in several countries and the use of this technology is expected to increase as a growing number of elderly people need to manage their medication at home. ADD aims to improve medication safety and treatment adherence, but it may introduce new safety issues. This descriptive study provides insight into the nature and consequences of medication incidents related to ADD, as reported by healthcare professionals in community pharmacies and hospitals. Methods The medication incidents that were submitted to the Dutch Central Medication incidents Registration (CMR) reporting system were selected and characterized independently by two researchers. Main Outcome Measures Person discovering the incident, phase of the medication process in which the incident occurred, immediate cause of the incident, nature of incident from the healthcare provider's perspective, nature of incident from the patient's perspective, and consequent harm to the patient caused by the incident. Results From January 2012 to February 2013 the CMR received 15,113 incidents: 3,685 (24.4%) incidents from community pharmacies and 11,428 (75.6%) incidents from hospitals. Eventually 1 of 50 reported incidents (268/15,113 = 1.8%) were related to ADD; in community pharmacies more incidents (227/3,685 = 6.2%) were related to ADD than in hospitals (41/11,428 = 0.4%). The immediate cause of an incident was often a change in the patient's medicine regimen or relocation. Most reported incidents occurred in two phases: entering the prescription into the pharmacy information system and filling the ADD bag. Conclusion A proportion of incidents was related to ADD and is reported regularly, especially by community pharmacies. In two phases, entering the prescription into the pharmacy information system and filling the ADD bag, most incidents occurred. A change in the patient's medicine regimen or relocation was the immediate causes of an incident

  4. Incidence and cost of medications dispensed despite electronic medical record discontinuation.

    Science.gov (United States)

    Baranowski, Patrick J; Peterson, Kristin L; Statz-Paynter, Jamie L; Zorek, Joseph A

    2015-01-01

    To determine the incidence and cost of medications dispensed despite discontinuation (MDDD) of the medications in the electronic medical record within an integrated health care organization. Dean Health System, with medical clinics and pharmacies linked by an electronic medical record, and a shared health plan and pharmacy benefits management company. Pharmacist-led quality improvement project using retrospective chart review. Electronic medical records, pharmacy records, and prescription claims data from patients 18 years of age or older who had a prescription filled for a chronic condition from June 2012 to August 2013 and submitted a claim through the Dean Health Plan were aggregated and cross-referenced to identify MDDD. Descriptive statistics were used to characterize demographics and MDDD incidence. Fisher's exact test and independent samples t tests were used to compare MDDD and non-MDDD groups. Wholesale acquisition cost was applied to each MDDD event. 7,406 patients met inclusion criteria. For 223 (3%) patients with MDDD, 253 independent events were identified. In terms of frequency per category, antihypertensive agents topped the list, followed, in descending order, by anticonvulsants, antilipemics, antidiabetics, and anticoagulants. Nine medications accounted for 59% (150 of 253) of all MDDD events; these included (again in descending order): gabapentin, atorvastatin, simvastatin, hydrochlorothiazide, lisinopril, warfarin, furosemide, metformin, and metoprolol. Mail-service pharmacies accounted for the highest incidence (5.3%) of MDDD, followed by mass merchandisers (4.6%) and small chains (3.9%). The total cost attributable to MDDD was $9,397.74. Development of a technology-based intervention to decrease the incidence of MDDD may be warranted to improve patient safety and decrease health care costs.

  5. Effects of a direct refill program for automated dispensing cabinets on medication-refill errors.

    Science.gov (United States)

    Helmons, Pieter J; Dalton, Ashley J; Daniels, Charles E

    2012-10-01

    The effects of a direct refill program for automated dispensing cabinets (ADCs) on medication-refill errors were studied. This study was conducted in designated acute care areas of a 386-bed academic medical center. A wholesaler-to-ADC direct refill program, consisting of prepackaged delivery of medications and bar-code-assisted ADC refilling, was implemented in the inpatient pharmacy of the medical center in September 2009. Medication-refill errors in 26 ADCs from the general medicine units, the infant special care unit, the surgical and burn intensive care units, and intermediate units were assessed before and after the implementation of this program. Medication-refill errors were defined as an ADC pocket containing the wrong drug, wrong strength, or wrong dosage form. ADC refill errors decreased by 77%, from 62 errors per 6829 refilled pockets (0.91%) to 8 errors per 3855 refilled pockets (0.21%) (p error type detected before the intervention was the incorrect medication (wrong drug, wrong strength, or wrong dosage form) in the ADC pocket. Of the 54 incorrect medications found before the intervention, 38 (70%) were loaded in a multiple-drug drawer. After the implementation of the new refill process, 3 of the 5 incorrect medications were loaded in a multiple-drug drawer. There were 3 instances of expired medications before and only 1 expired medication after implementation of the program. A redesign of the ADC refill process using a wholesaler-to-ADC direct refill program that included delivery of prepackaged medication and bar-code-assisted refill significantly decreased the occurrence of ADC refill errors.

  6. The cytosolic glyoxalases of Plasmodium falciparum are dispensable during asexual blood-stage development

    Directory of Open Access Journals (Sweden)

    Cletus A. Wezena

    2017-11-01

    Full Text Available The enzymes glyoxalase 1 and 2 (Glo1 and Glo2 are found in most eukaryotes and catalyze the glutathione-dependent conversion of 2-oxoaldehydes to 2-hydroxycarboxylic acids. Four glyoxalases are encoded in the genome of the malaria parasite Plasmodium falciparum, the cytosolic enzymes PfGlo1 and PfcGlo2, the apicoplast enzyme PftGlo2, and an inactive Glo1-like protein that also carries an apicoplast-targeting sequence. Inhibition or knockout of the Plasmodium glyoxalases was hypothesized to lead to an accumulation of 2-oxoaldehydes and advanced glycation end-products (AGE in the host-parasite unit and to result in parasite death. Here, we generated clonal P. falciparum strain 3D7 knockout lines for PFGLO1 and PFcGLO2 using the CRISPR-Cas9 system. Although 3D7Δglo1 knockout clones had an increased susceptibility to external glyoxal, all 3D7Δglo1 and 3D7Δcglo2 knockout lines were viable and showed no significant growth phenotype under standard growth conditions. Furthermore, the lack of PfcGlo2, but not PfGlo1, increased gametocyte commitment in the knockout lines. In summary, PfGlo1 and PfcGlo2 are dispensable during asexual blood-stage development while the loss of PfcGlo2 may induce the formation of transmissible gametocytes. These combined data show that PfGlo1 and PfcGlo2 are most likely not suited as targets for selective drug development.

  7. Mouse Panx1 Is Dispensable for Hearing Acquisition and Auditory Function

    Directory of Open Access Journals (Sweden)

    Veronica Zorzi

    2017-11-01

    Full Text Available Panx1 forms plasma membrane channels in brain and several other organs, including the inner ear. Biophysical properties, activation mechanisms and modulators of Panx1 channels have been characterized in detail, however the impact of Panx1 on auditory function is unclear due to conflicts in published results. To address this issue, hearing performance and cochlear function of the Panx1−/− mouse strain, the first with a reported global ablation of Panx1, were scrutinized. Male and female homozygous (Panx1−/−, hemizygous (Panx1+/− and their wild type (WT siblings (Panx1+/+ were used for this study. Successful ablation of Panx1 was confirmed by RT-PCR and Western immunoblotting in the cochlea and brain of Panx1−/− mice. Furthermore, a previously validated Panx1-selective antibody revealed strong immunoreactivity in WT but not in Panx1−/− cochleae. Hearing sensitivity, outer hair cell-based “cochlear amplifier” and cochlear nerve function, analyzed by auditory brainstem response (ABR and distortion product otoacoustic emission (DPOAE recordings, were normal in Panx1+/− and Panx1−/− mice. In addition, we determined that global deletion of Panx1 impacts neither on connexin expression, nor on gap-junction coupling in the developing organ of Corti. Finally, spontaneous intercellular Ca2+ signal (ICS activity in organotypic cochlear cultures, which is key to postnatal development of the organ of Corti and essential for hearing acquisition, was not affected by Panx1 ablation. Therefore, our results provide strong evidence that, in mice, Panx1 is dispensable for hearing acquisition and auditory function.

  8. Sialylation of lipooligosaccharides is dispensable for the virulence of Haemophilus ducreyi in humans.

    Science.gov (United States)

    Spinola, Stanley M; Li, Wei; Fortney, Kate R; Janowicz, Diane M; Zwickl, Beth; Katz, Barry P; Munson, Robert S

    2012-02-01

    Sialylated glycoconjugates on the surfaces of mammalian cells play important roles in intercellular communication and self-recognition. The sialic acid preferentially expressed in human tissues is N-acetylneuraminic acid (Neu5Ac). In a process called molecular mimicry, many bacterial pathogens decorate their cell surface glycolipids with Neu5Ac. Incorporation of Neu5Ac into bacterial glycolipids promotes bacterial interactions with host cell receptors called Siglecs. These interactions affect bacterial adherence, resistance to serum killing and phagocytosis, and innate immune responses. Haemophilus ducreyi, the etiologic agent of chancroid, expresses lipooligosaccharides (LOS) that are highly sialylated. However, an H. ducreyi sialyltransferase (lst) mutant, whose LOS contain reduced levels of Neu5Ac, is fully virulent in human volunteers. Recently, a second sialyltransferase gene (Hd0053) was discovered in H. ducreyi, raising the possibility that Hd0053 compensated for the loss of lst during human infection. CMP-Neu5Ac is the obligate nucleotide sugar donor for all bacterial sialyltransferases; LOS derived from an H. ducreyi CMP-Neu5Ac synthetase (neuA) mutant has no detectable Neu5Ac. Here, we compared an H. ducreyi neuA mutant to its wild-type parent in several models of pathogenesis. In human inoculation experiments, the neuA mutant formed papules and pustules at rates that were no different than those of its parent. When grown in media with and without Neu5Ac supplementation, the neuA mutant and its parent had similar phenotypes in bactericidal, macrophage uptake, and dendritic cell activation assays. Although we cannot preclude a contribution of LOS sialylation to ulcerative disease, these data strongly suggest that sialylation of LOS is dispensable for H. ducreyi pathogenesis in humans.

  9. An analysis of the utilisation and expenditure of medicines dispensed for the management of severe asthma.

    LENUS (Irish Health Repository)

    McGowan, B

    2009-03-01

    There are approximately 6,300 people in Ireland with a diagnosis of Chronic Obstructive Pulmonary Disease (COPD) and with a fast growing elderly population the incidence of COPD is likely to increase. This study examines the prescribing patterns of medicines dispensed for the management Asthma\\/COPD in patients over the age of 35 years using the HSE-Primary Care Reimbursement Services (PCRS) prescribing databases. The HSE-PCRS pharmacy claims data, which covers all those over 70 years of age and means tested for those less than 70 years, was analysed for the years 2005\\/2006. Approximately 26,548 (17.9%) of patients who were prescribed a respiratory drug received inhaled short-acting beta2 agonists in combination with a regular standard-dose inhaled corticosteroid. A further 5,044 (3.4%) were also prescribed a regular inhaled long-acting beta2 agonist (salmeterol or formoterol). A total of 2506 patients (6.2%) on combination therapy were co-prescribed four different anti-asthmatic treatments inclusive of oral prednisolone. A small proportion of the patients prescribed a respiratory drug were co-prescribed nicotine replacement therapy (n = 5177, 3.5%). In total there were 9,728 (6.2%) patients prescribed a mucolytic drug in combination with a respiratory drug and the rate of co-prescribing with antibiotics was 22%. COPD is a debilitating disease that is primarily caused by smoking and is therefore largely preventable. The HSE-PCRS pharmacy claims data is a valuable tool for helping to assess the burden of this disease in the Irish context.

  10. SCD1 Expression is dispensable for hepatocarcinogenesis induced by AKT and Ras oncogenes in mice.

    Directory of Open Access Journals (Sweden)

    Lei Li

    Full Text Available Increased de novo lipogenesis is one of the major metabolic events in cancer. In human hepatocellular carcinoma (HCC, de novo lipogenesis has been found to be increased and associated with the activation of AKT/mTOR signaling. In mice, overexpression of an activated form of AKT results in increased lipogenesis and hepatic steatosis, ultimately leading to liver tumor development. Hepatocarcinogenesis is dramatically accelerated when AKT is co-expressed with an oncogenic form of N-Ras. SCD1, the major isoform of stearoyl-CoA desaturases, catalyzing the conversion of saturated fatty acids (SFA into monounsaturated fatty acids (MUFA, is a key enzyme involved in de novo lipogenesis. While many studies demonstrated the requirement of SCD1 for tumor cell growth in vitro, whether SCD1 is necessary for tumor development in vivo has not been previously investigated. Here, we show that genetic ablation of SCD1 neither inhibits lipogenesis and hepatic steatosis in AKT-overexpressing mice nor affects liver tumor development in mice co-expressing AKT and Ras oncogenes. Molecular analysis showed that SCD2 was strongly upregulated in liver tumors from AKT/Ras injected SCD1(-/- mice. Noticeably, concomitant silencing of SCD1 and SCD2 genes was highly detrimental for the growth of AKT/Ras cells in vitro. Altogether, our study provides the evidence, for the first time, that SCD1 expression is dispensable for AKT/mTOR-dependent hepatic steatosis and AKT/Ras-induced hepatocarcinogenesis in mice. Complete inhibition of stearoyl-CoA desaturase activity may be required to efficiently suppress liver tumor development.

  11. Notch3 is dispensable for thymocyte β-selection and Notch1-induced T cell leukemogenesis.

    Directory of Open Access Journals (Sweden)

    Sara Suliman

    Full Text Available Notch1 (N1 signaling induced by intrathymic Delta-like (DL ligands is required for T cell lineage commitment as well as self-renewal during "β-selection" of TCRβ⁺CD4⁻CD8⁻ double negative 3 (DN3 T cell progenitors. However, over-expression of the N1 intracellular domain (ICN1 renders N1 activation ligand-independent and drives leukemic transformation during β-selection. DN3 progenitors also express Notch3 (N3 mRNA, and over-expression of ligand-independent mutant N3 (ICN3 influences β-selection and drives T cell leukemogenesis. However, the importance of ligand-activated N3 in promoting β-selection and ICN1-induced T cell leukemogenesis has not been examined. To address these questions we generated mice lacking functional N3. We confirmed that DN3 progenitors express N3 protein using a N3-specific antibody. Surprisingly however, N3-deficient DN3 thymocytes were not defective in generating DP thymocytes under steady state conditions or in more stringent competition assays. To determine if N3 co-operates with N1 to regulate β-selection, we generated N1;N3 compound mutants. However, N3 deficiency did not exacerbate the competitive defect of N1⁺/⁻ DN3 progenitors, demonstrating that N3 does not compensate for limiting N1 during T cell development. Finally, N3 deficiency did not attenuate T cell leukemogenesis induced by conditional expression of ICN1 in DN3 thymocytes. Importantly, we showed that in contrast to N1, N3 has a low binding affinity for DL4, the most abundant intrathymic DL ligand. Thus, despite the profound effects of ectopic ligand-independent N3 activation on T cell development and leukemogenesis, physiologically activated N3 is dispensable for both processes, likely because N3 interacts poorly with intrathymic DL4.

  12. Įvairialyčiai lantano ir mangano oksido ir multiferoinio bismuto ferito heterodariniai

    Directory of Open Access Journals (Sweden)

    Bonifacas VENGALIS

    2011-11-01

    Full Text Available Pastaruoju metu naujų elektronikos prietaisų gamyboje buvo pasiekta didelė pažanga auginant, tyrinėjant ir pritaikant plonasluoksnes struktūras, sudarytas iš įvairių daugiakomponenčių funkcinių oksidų. Šiai oksidų grupei priklauso superlaidieji kupratai, mangano oksidai (manganitai, pasižymintys magnetovaržos reiškiniu, taip pat kiti feromagnetiniai, feroelektriniai, multiferoiniai oksidai. Manganitams (jų bendra formulė Ln1-xAxMnO3, kur Ln = La, Nd,..., o A - dvivalentis katijonas, toks kaip Ba, Sr ar Ca skiriama daug dėmesio dėl jų įdomių elektrinių savybių bei tinkamumo įvairiems spintronikos prietaisams kurti. Multiferoikai  (feroelektriniai feromagnetai pasižymi magnetoelektriniu efektu, duodančiu unikalią galimybę elektrinėms ir magnetinėms medžiagos savybėms valdyti panaudoti elektrinius ir magnetinius laukus. Bismuto feritas BiFeO3 (BFO, turintis romboedriškai deformuotą perovskito struktūrą, šiuo metu yra vienas labiausiai tyrinėjamų šios klasės junginių. Organiniai puslaidininkiai (OP taip pat atveria daug naujų galimybių elektronikai. Jų pranašumas yra didelė organinių junginių įvairovė ir palyginti paprasta ir pigi plonų sluoksnių gamybos technologija. Be to, OP pasižymi neįprastai didelėmis sukinių relaksacijos laiko vertėmis, todėl ateityje jie gali būti naudojami naujiems spintronikos prietaisams gaminti. Šiame straipsnyje apžvelgiami pastarųjų metų darbo autorių ir jų kolegų atlikti anksčiau minėtų medžiagų tyrimai. Daugiausia dėmesio skiriama magnetovaržinėmis savybėmis pasižyminčių lantano ir mangano oksidų (manganitų bei multiferoinio  BiFeO3 (BFO junginio plonųjų sluoksnių ir heterodarinių auginimui, tarpfazinių ribų tarp minėtų oksidų, laidžiojo SrTiO3 ir organinio puslaidininkio (Alq3 sudarymui, taip pat elektrinėms heterodarinių savybėms. Plonieji La2/3A1/3MnO3 (A = Ca, Sr, Ba, Ce sluoksniai, kurių storis d

  13. Role of IRS-2 in insulin and cytokine signalling.

    Science.gov (United States)

    Sun, X J; Wang, L M; Zhang, Y; Yenush, L; Myers, M G; Glasheen, E; Lane, W S; Pierce, J H; White, M F

    1995-09-14

    The protein IRS-1 acts as an interface between signalling proteins with Src-homology-2 domains (SH2 proteins) and the receptors for insulin, IGF-1, growth hormone, several interleukins (IL-4, IL-9, IL-13) and other cytokines. It regulates gene expression and stimulates mitogenesis, and appears to mediate insulin/IGF-1-stimulated glucose transport. Thus, survival of the IRS-1-/- mouse with only mild resistance to insulin was surprising. This dilemma is provisionally resolved with our discovery of a second IRS-signalling protein. We purified and cloned a likely candidate called 4PS from myeloid progenitor cells and, because of its resemblance to IRS-1, we designate it IRS-2. Alignment of the sequences of IRS-2 and IRS-1 revealed a highly conserved amino terminus containing a pleckstrin-homology domain and a phosphotyrosine-binding domain, and a poorly conserved carboxy terminus containing several tyrosine phosphorylation motifs. IRS-2 is expressed in many cells, including tissues from IRS-1-/- mice, and may be essential for signalling by several receptor systems.

  14. Medicare Modernization Act (MMA) IRS Medicare Part D

    Data.gov (United States)

    Social Security Administration — SSA uses the Internal Revenue Service (IRS) information in determing the eligibility of Medicare recipients to receive subsidy payments for Medicare premiums. SSA...

  15. Distinct signalling properties of insulin receptor substrate (IRS)-1 and IRS-2 in mediating insulin/IGF-1 action.

    Science.gov (United States)

    Rabiee, Atefeh; Krüger, Marcus; Ardenkjær-Larsen, Jacob; Kahn, C Ronald; Emanuelli, Brice

    2018-07-01

    Insulin/IGF-1 action is driven by a complex and highly integrated signalling network. Loss-of-function studies indicate that the major insulin/IGF-1 receptor substrate (IRS) proteins, IRS-1 and IRS-2, mediate different biological functions in vitro and in vivo, suggesting specific signalling properties despite their high degree of homology. To identify mechanisms contributing to the differential signalling properties of IRS-1 and IRS-2 in the mediation of insulin/IGF-1 action, we performed comprehensive mass spectrometry (MS)-based phosphoproteomic profiling of brown preadipocytes from wild type, IRS-1 -/- and IRS-2 -/- mice in the basal and IGF-1-stimulated states. We applied stable isotope labeling by amino acids in cell culture (SILAC) for the accurate quantitation of changes in protein phosphorylation. We found ~10% of the 6262 unique phosphorylation sites detected to be regulated by IGF-1. These regulated sites included previously reported substrates of the insulin/IGF-1 signalling pathway, as well as novel substrates including Nuclear Factor I X and Semaphorin-4B. In silico prediction suggests the protein kinase B (PKB), protein kinase C (PKC), and cyclin-dependent kinase (CDK) as the main mediators of these phosphorylation events. Importantly, we found preferential phosphorylation patterns depending on the presence of either IRS-1 or IRS-2, which was associated with specific sets of kinases involved in signal transduction downstream of these substrates such as PDHK1, MAPK3, and PKD1 for IRS-1, and PIN1 and PKC beta for IRS-2. Overall, by generating a comprehensive phosphoproteomic profile from brown preadipocyte cells in response to IGF-1 stimulation, we reveal both common and distinct insulin/IGF-1 signalling events mediated by specific IRS proteins. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. HOMA1-IR and HOMA2-IR indexes in identifying insulin resistance and metabolic syndrome - Brazilian Metabolic Syndrome Study (BRAMS)

    OpenAIRE

    Geloneze, B; Vasques, ACJ; Stabe, CFC; Pareja, JC; Rosado, LEFPD; de Queiroz, EC; Tambascia, MA

    2009-01-01

    Objective: To investigate cut-off values for HOMA1-IR and HOMA2-IR to identify insulin resistance (IR) and metabolic syndrome (MS), and to assess the association of the indexes with components of the MS. Methods: Nondiabetic subjects from the Brazilian Metabolic Syndrome Study were studied (n = 1,203, 18 to 78 years). The cut-off values for IR were determined from the 9011 percentile in the healthy group (n = 297) and, for MS, a ROC curve was generated for the total sample. Results: In the he...

  17. Growth and phase transformations of Ir on Ge(111)

    Science.gov (United States)

    Mullet, C. H.; Stenger, B. H.; Durand, A. M.; Morad, J. A.; Sato, Y.; Poppenheimer, E. C.; Chiang, S.

    2017-12-01

    The growth of Ir on Ge(111) as a function of temperature between 23 °C and 820 °C is characterized with low energy electron microscopy (LEEM), low energy electron diffraction (LEED), scanning tunneling microscopy (STM), and x-ray photoemission spectroscopy (XPS). Deposition onto a substrate at 350 °C revealed a novel growth mode consisting of multilayer Ir islands with (√3 × √3)R30° (abbreviated as √3) structure interconnected by ;bridges; of single-layer Ir several atoms wide. For deposition onto substrates above 500 °C, the √3 Ir phase grows with dendritic morphology, and substrate step bunches act as barriers to √3 Ir growth. LEEM images showed Stranski-Krastanov growth for 650-820 °C: after the √3 phase covers the surface, corresponding to 2 monolayers (ML) Ir coverage, multilayer hexagonal-shaped Ir islands form, surrounded by regions of IrGe alloy. Hexagonal-shaped Ir islands also formed upon heating 1.2 ML of √3 Ir beyond 830 °C, which resulted in the elimination of √3 structure from the surface. The transformation from √3 to (1 × 1) structure upon heating to 830 °C was an irreversible surface phase transition. Annealing > 2.0 ML of Ir in the √3 phase above the 830 °C disorder temperature, followed by cooling, produced a (3 × 1) structure. Subsequent heating and cooling through 830 °C give evidence for a reversible (3 × 1) to (1 × 1) phase transition.

  18. Structural, phase stability, electronic, elastic properties and hardness of IrN{sub 2} and zinc blende IrN: First-principles calculations

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Zhaobo [Key Laboratory of Advanced Materials of Yunnan Province & Key Laboratory of Advanced Materials of Non-Ferrous and Precious Rare Metals Ministry of Education, Kunming University of Science and Technology, Kunming 650093 (China); Zhou, Xiaolong, E-mail: kmzxlong@163.com [Key Laboratory of Advanced Materials of Yunnan Province & Key Laboratory of Advanced Materials of Non-Ferrous and Precious Rare Metals Ministry of Education, Kunming University of Science and Technology, Kunming 650093 (China); Zhang, Kunhua [State Key Laboratory of Rare Precious Metals Comprehensive Utilization of New Technologies, Kunming Institute of Precious Metals, Kunming 650106 (China)

    2016-12-15

    First-principle calculations were performed to investigate the structural, phase stability, electronic, elastic properties and hardness of monoclinic structure IrN{sub 2} (m-IrN{sub 2}), orthorhombic structure IrN{sub 2} (o-IrN{sub 2}) and zinc blende structure IrN (ZB IrN). The results show us that only m-IrN{sub 2} is both thermodynamic and dynamic stability. The calculated band structure and density of states (DOS) curves indicate that o-IrN{sub 2} and ZB Ir-N compounds we calculated have metallic behavior while m-IrN{sub 2} has a small band gap of ~0.3 eV, and exist a common hybridization between Ir-5d and N-2p states, which forming covalent bonding between Ir and N atoms. The difference charge density reveals the electron transfer from Ir atom to N atom for three Ir-N compounds, which forming strong directional covalent bonds. Notable, a strong N-N bond appeared in m-IrN{sub 2} and o-IrN{sub 2}. The ratio of bulk to shear modulus (B/G) indicate that three Ir-N compounds we calculated are ductile, and ZB IrN possesses a better ductility than two types IrN{sub 2}. m-IrN{sub 2} has highest Debye temperature (736 K), illustrating it possesses strongest covalent bonding. The hardness of three Ir-N compounds were also calculated, and the results reveal that m-IrN{sub 2} (18.23 GPa) and o-IrN{sub 2} (18.02 GPa) are ultraincompressible while ZB IrN has a negative value, which may be attributed to phase transition at ca. 1.98 GPa.

  19. The degree of integration of non-dispensing pharmacists in primary care practice and the impact on health outcomes: A systematic review.

    Science.gov (United States)

    Hazen, Ankie C M; de Bont, Antoinette A; Boelman, Lia; Zwart, Dorien L M; de Gier, Johan J; de Wit, Niek J; Bouvy, Marcel L

    2018-03-01

    A non-dispensing pharmacist conducts clinical pharmacy services aimed at optimizing patients individual pharmacotherapy. Embedding a non-dispensing pharmacist in primary care practice enables collaboration, probably enhancing patient care. The degree of integration of non-dispensing pharmacists into multidisciplinary health care teams varies strongly between settings. The degree of integration may be a determinant for its success. This study investigates how the degree of integration of a non-dispensing pharmacist impacts medication related health outcomes in primary care. In this literature review we searched two electronic databases and the reference list of published literature reviews for studies about clinical pharmacy services performed by non-dispensing pharmacists physically co-located in primary care practice. We assessed the degree of integration via key dimensions of integration based on the conceptual framework of Walshe and Smith. We included English language studies of any design that had a control group or baseline comparison published from 1966 to June 2016. Descriptive statistics were used to correlate the degree of integration to health outcomes. The analysis was stratified for disease-specific and patient-centered clinical pharmacy services. Eighty-nine health outcomes in 60 comparative studies contributed to the analysis. The accumulated evidence from these studies shows no impact of the degree of integration of non-dispensing pharmacists on health outcomes. For disease specific clinical pharmacy services the percentage of improved health outcomes for none, partial and fully integrated NDPs is respectively 75%, 63% and 59%. For patient-centered clinical pharmacy services the percentage of improved health outcomes for none, partial and fully integrated NDPs is respectively 55%, 57% and 70%. Full integration adds value to patient-centered clinical pharmacy services, but not to disease-specific clinical pharmacy services. To obtain maximum benefits

  20. Methodological challenges in assessment of current use of warfarin among patients with atrial fibrillation using dispensation data from administrative health care databases.

    Science.gov (United States)

    Sinyavskaya, Liliya; Matteau, Alexis; Johnson, Sarasa; Durand, Madeleine

    2018-06-05

    Algorithms to define current exposure to warfarin using administrative data may be imprecise. Study objectives were to characterize dispensation patterns, to measure gaps between expected and observed refill dates for warfarin and direct oral anticoagulants (DOACs). Retrospective cohort study using administrative health care databases of the Régie de l'assurance-maladie du Québec. We identified every dispensation of warfarin, dabigatran, rivaroxaban, or apixaban for patients with AF initiating oral anticoagulants between 2010 and 2015. For each dispensation, we extracted date and duration. Refill gaps were calculated as difference between expected and observed dates of successive dispensation. Refill gaps were summarized using descriptive statistics. To account for repeated observations nested within patients and to assess the components of variance of refill gaps, we used unconditional multilevel linear models. We identified 61 516 new users. Majority were prescribed warfarin (60.3%), followed by rivaroxaban (16.4%), dabigatran (14.5%), apixaban (8.8%). Most frequent recorded duration of dispensation was 7 days, suggesting use of pharmacist-prepared weekly pillboxes. The average refill gap from multilevel model was higher for warfarin (9.28 days, 95%CI:8.97-9.59) compared with DOACs (apixaban 3.08 days, 95%CI: 2.96-3.20, dabigatran 3.70, 95%CI: 3.56-3.84, rivaroxaban 3.15, 95%CI: 3.03-3.27). The variance of refill gaps was greater among warfarin users than among DOAC users. Greater refill gaps for warfarin may reflect inadequate capture of the period covered by the number of dispensed pills recorded in administrative data. A time-dependent definition of exposure using dispensation data would lead to greater misclassification of warfarin than DOACs use. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Technical specification for IR rig manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Han Hyon Soo; Cho, W. K.; Kim, S. D.; Park, U. J.; Hong, S. B.; Yoo, K. M

    2000-10-01

    IR Rig is one of the equipments are required in HANARO core for a radioisotope target. The various conditions like high radiation, high heat, rapid flow and vibration may cause swelling, Brittleness and acceleration of corrosion in HANARO core. These specific problems can be prevented and the safety of such equipment are prerequisite as well as durableness and surveillance. Therefore, the selection of material has to be made on the basis of small cross-section area, low energy emission by the gamma ray due to the absorption of neutron and short half life. The body is consist of aluminum and Inconel-750 was used for the internal spring(coil) which is known to be durable. The whole production process including the purchase of accessory, mechanical processing, welding and assembly was carried out according to the standard procedure to meet the requirement. A design, manufacture, utilization of reactor core and the other relevant uses were fit to class ''T'' to certify the whole process as general. And design, fabrication, analytical test, materials and accessory were carried out based on the ASME, ASTM, ANSI, AWS, JIS and KS standard.

  2. Characterization of Hydrogen Bonds by IR Spectroscopy

    Directory of Open Access Journals (Sweden)

    Vojta, D.

    2012-05-01

    Full Text Available In the identification and quantification of hydrogen bond, as one of the most abundant non-covalent interactions in phenomena like self-assembly and molecular recognition, IR spectrosopy has been employed as the most sensitive method. The performance of the high dilution method enables determination of the stability constant of hydrogen-bonded complex as one of the most important thermodynamic quantities used in their characterization. However, the alleged experimental simplicity of the mentioned method is loaded with errors originating not only from researcher intervention but also independent from it. The second source of error is particularly emphasized and elaborated in this paper, which is designed as the recipe for the successful characterization of hydrogen bonds. Besides the enumeration of all steps in the determination of hydrogen-bonded stability constants, the reader can be acquainted with the most important ex perimental conditions that should be fulfilled in order to minimize the naturally occurring errors in this type of investigation. In the spectral analysis, the application of both uni- and multivariate approach has been discussed. Some computer packages, considering the latter, are mentioned, described, and recommended. KUI -10/2012Received August 1, 2011Accepted October 24, 2011

  3. The nature of OH/IR stars

    International Nuclear Information System (INIS)

    Herman, J.

    1983-01-01

    In this work masers in evolved stars are studied, in particular the emission from the OH radical. The time variability of the OH masers was measured over a period of five years with the Dwingeloo Radio Telescope. These single-dish observations proved that most of the underlying stars are very long period variables, apparently a kind of extension of the well-known long period Mira variables. The mean OH fluxes and epochs were obtained as well as a confirmation of the radiative coupling between the maser and the star (by comparison with infrared data provided by other observers), the degree of saturation, and, most important of all, a determination of the linear dimensions of the circumstellar shells. Multi-element interferometer observations were made in order to study the spatial structure of OH masers. By combining the phase lag measurements and the spatial extent distances to individual stars could be determined with a high, unprecedented accuracy. Infrared broad-band photometry was done in the wavelength region from 3 μm to 20 μm, where most of the energy of these objects is radiated. The space density and galactic distribution of OH/IR stars are discussed and compared with the appearance of OH masers in the solar neighbourhood. (Auth.)

  4. Publicité alimentaire destinée aux enfants : examen de la portée de l’exposition, du pouvoir et des répercussions selon le contexte

    Directory of Open Access Journals (Sweden)

    Rachel Prowse

    2017-01-01

    Full Text Available Introduction : La publicité alimentaire a des répercussions sur les connaissances et les comportements alimentaires des enfants ainsi que sur leur santé. La réglementation actuelle au Canada est axée sur la restriction des aspects promotionnels de la publicité alimentaire, mais elle accorde peu d’attention, voire aucune, à l’endroit où se fait l’expérience alimentaire des enfants. Il est essentiel de comprendre où s’inscrit la publicité alimentaire dans le quotidien des enfants pour pouvoir les protéger. Notre étude fait état de la littérature sur la publicité alimentaire destinée aux enfants au Canada en fonction du contexte. Méthodologie : L’auteure a consulté des bases de données pour trouver des travaux de recherche canadiens portant sur l’exposition des enfants et des jeunes (de 2 à 17 ans à la publicité alimentaire, sur le pouvoir et les répercussions que celle-ci peut avoir sur les enfants dans différents contextes et sur la façon dont la réglementation actuelle peut en atténuer l'effet sur les enfants. Ont été sélectionnées les études en anglais, examinées par des pairs et publiées entre 2000 et 2016. Résultats : Vingt-cinq études se sont intéressées à l’exposition des enfants à la publicité alimentaire et au pouvoir ou aux répercussions qu’elle peut avoir sur ceux-ci à la maison (par la télévision ou Internet (n = 12, dans les écoles publiques (n = 1, dans les épiceries (n = 8, dans les restaurants rapides (n = 2 et en général (n = 2. Les tendances de la recherche révèlent que les aliments malsains ciblent les enfants par différentes techniques promotionnelles, qui se chevauchent selon les contextes. Il existe plusieurs lacunes en matière de recherche dans ce domaine, ce qui donne un portrait incomplet et potentiellement sous-estimé de la publicité alimentaire destinée aux enfants au Canada. Les données probantes disponibles indiquent que les approches canadiennes

  5. Operational experience - Lessons learned from IRS-reports in Germany

    International Nuclear Information System (INIS)

    Wetzel, N.; Maqua, M.

    2005-01-01

    The international Incident Reporting System (IRS), jointly operated by IAEA and OECD-NEA, is a main source of safety significant findings and lessons learned of nuclear operating experience. GRS (Gesellschaft fuer Anlagen- und Reaktorsicherheit mbH) is a scientific-technical expert and research organisation. On Behalf of the Federal Minister of Environment, Nature Conservation and Reactor Safety (BMU), GRS provides the IRS officer. The evaluation of IRS-Reports and the dissemination of the main findings including the assessment of the relevance for German NPPs is task of GRS. The value of IRS is among experts undoubted. But nevertheless, the reporting to IRS decreases since some years. This presentation is aimed to show the support of IRS in strengthening the safety of German NPPs. The evaluation of IRS-Reports at GRS is three-fold. It comprises initial screening, quarterly and yearly reporting and the development of specific German Information Notices on safety significant events with direct applicability to German NPPs. Some examples of lessons learned from recent international events are discussed below. These examples shall demonstrate that the use of the IRS enhances significantly the knowledge on operational events. (author)

  6. Upconversion imager measures single mid-IR photons

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2013-01-01

    the performance of today's state of the art IR detectors for the visible/near-IR region shows a striking contrast, as the latter can have dark currents in the range of 0.001 electrons per second. Demonstrated performance of waveguide upconversion techniques still show considerable dark noise, even when working...

  7. NaIrO3-A pentavalent post-perovskite

    International Nuclear Information System (INIS)

    Bremholm, M.; Dutton, S.E.; Stephens, P.W.; Cava, R.J.

    2011-01-01

    Sodium iridium (V) oxide, NaIrO 3, was synthesized by a high pressure solid state method and recovered to ambient conditions. It is found to be isostructural with CaIrO 3 , the much-studied structural analog of the high-pressure post-perovskite phase of MgSiO 3 . Among the oxide post-perovskites, NaIrO 3 is the first example with a pentavalent cation. The structure consists of layers of corner- and edge-sharing IrO 6 octahedra separated by layers of NaO 8 bicapped trigonal prisms. NaIrO 3 shows no magnetic ordering and resistivity measurements show non-metallic behavior. The crystal structure, electrical and magnetic properties are discussed and compared to known post-perovskites and pentavalent perovskite metal oxides. -- Graphical abstract: Sodium iridium(V) oxide, NaIrO 3 , synthesized by a high pressure solid state method and recovered to ambient conditions is found to crystallize as the post-perovskite structure and is the first example of a pentavalent ABO 3 post-perovskite. Research highlights: → NaIrO 3 post-perovskite stabilized by pressure. → First example of a pentavalent oxide post-perovskite. → Non-metallic and non-magnetic behavior of NaIrO 3 .

  8. Health care professionals’ perspectives on automated multi-dose drug dispensing

    Directory of Open Access Journals (Sweden)

    Bardage C

    2014-12-01

    Full Text Available Background: During the 1980s, manual repackaging of multi-dose medications from pharmacies in Sweden was successively substituted with automated multi-dose drug dispensing (MDD. There are few studies evaluating the consequences of automated MDD with regard to patient safety, and those that investigate this issue are not very extensive. Objectives: To investigate Swedish health care professionals’ perceived experience of automated MDD and its effects on patient adherence and patient safety. Methods: Three questionnaire forms, one for physicians, nurses, and assistant nurses/nursing assistants, were developed based on reviews of the literature and pilot testing of the questions in the intended target groups. The target groups were health professionals prescribing or administrating MDD to patients. A sample (every sixth municipality was drawn from the sampling frame of Swedish municipalities, resulting in 40 municipalities, about 14% of all municipalities in Sweden. Email addresses of general practitioners were obtained from county councils, while the municipalities assisted in getting contact details for nurses, assistant nurses and nursing assistants. A total of 915 questionnaires were distributed electronically to physicians, 515 to nurses, and 4,118 to assistant nurses/nursing assistants. The data were collected in September and October 2012. Results: The response rate among physicians, nurses and assistant nurses/nursing assistants was 31%, 43% and 23%, respectively. The professionals reported that automated MDD reduces duplication of medication, contributes to correct dosages, helps patients take their medication at the right time, and reduces confusion among patients. Fifteen per cent of the physicians and about one-third of the nurses and assistant nurses/nursing assistants reported that generic substitution makes it more difficult for the patient to identify the various medicines available in the sachets. The physicians did, however

  9. Analyzing the effectiveness of flare dispensing programs against pulse width modulation seekers using self-organizing maps

    Science.gov (United States)

    Şahingil, Mehmet C.; Aslan, Murat Š.

    2013-10-01

    Infrared guided missile seekers utilizing pulse width modulation in target tracking is one of the threats against air platforms. To be able to achieve a "soft-kill" protection of own platform against these type of threats, one needs to examine carefully the seeker operating principle with its special electronic counter-counter measure (ECCM) capability. One of the cost-effective ways of soft kill protection is to use flare decoys in accordance with an optimized dispensing program. Such an optimization requires a good understanding of the threat seeker, capabilities of the air platform and engagement scenario information between them. Modeling and simulation is very powerful tool to achieve a valuable insight and understand the underlying phenomenology. A careful interpretation of simulation results is crucial to infer valuable conclusions from the data. In such an interpretation there are lots of factors (features) which affect the results. Therefore, powerful statistical tools and pattern recognition algorithms are of special interest in the analysis. In this paper, we show how self-organizing maps (SOMs), which is one of those powerful tools, can be used in analyzing the effectiveness of various flare dispensing programs against a PWM seeker. We perform several Monte Carlo runs for a typical engagement scenario in a MATLAB-based simulation environment. In each run, we randomly change the flare dispending program and obtain corresponding class: "successful" or "unsuccessful", depending on whether the corresponding flare dispensing program deceives the seeker or not, respectively. Then, in the analysis phase, we use SOMs to interpret and visualize the results.

  10. On demand manufacturing of patient-specific liquid capsules via co-ordinated 3D printing and liquid dispensing.

    Science.gov (United States)

    Okwuosa, Tochukwu C; Soares, Cindy; Gollwitzer, Verena; Habashy, Rober; Timmins, Peter; Alhnan, Mohamed A

    2018-06-15

    A method for the production of liquid capsules with the potential of modifying drug dose and release is presented. For the first time, the co-ordinated use of fused deposition modelling (FDM), 3D printing and liquid dispensing to fabricate individualised dosage form on demand in a fully automated fashion has been demonstrated. Polymethacrylate shells (Eudragit EPO and RL) for immediate and extended release were fabricated using FDM 3D printing and simultaneously filled using a computer-controlled liquid dispenser loaded with model drug solution (theophylline) or suspension (dipyridamole). The impact of printing modes: simultaneous shell printing and filling (single-phase) or sequential 3D printing of shell bottom, filling and shell cap (multi-phase), nozzle size, syringe volume, and shell structure has been reported. The use of shell thickness of 1.6 mm, and concentric architecture allowed successful containment of liquid core whilst maintaining the release properties of the 3D printed liquid capsule. The linear relationship between the theoretical and the actual volumes from the dispenser reflected its potential for accurate dosing (R 2  = 0.9985). Modifying the shell thickness of Eudragit RL capsule allowed a controlled extended drug release without the need for formulation change. Owing to its low cost and versatility, this approach can be adapted to wide spectrum of liquid formulations such as small and large molecule solutions and obviate the need for compatibility with the high temperature of FDM 3D printing process. In a clinical setting, health care staff will be able to instantly manufacture in small volumes liquid capsules with individualised dose contents and release pattern in response to specific patient's needs. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Defense Strategy of Aircraft Confronted with IR Guided Missile

    Directory of Open Access Journals (Sweden)

    Hesong Huang

    2017-01-01

    Full Text Available Surface-type infrared (IR decoy can simulate the IR characteristics of the target aircraft, which is one of the most effective equipment to confront IR guided missile. In the air combat, the IR guided missile poses a serious threat to the aircraft when it comes from the front of target aircraft. In this paper, firstly, the model of aircraft and surface-type IR decoy is established. To ensure their authenticity, the aircraft maneuver and radiation models based on real data of flight and exhaust system radiation in the state of different heights and different speeds are established. Secondly, the most effective avoidance maneuver is simulated when the missile comes from the front of the target aircraft. Lastly, combining maneuver with decoys, the best defense strategy is analysed when the missile comes from the front of aircraft. The result of simulation, which is authentic, is propitious to avoid the missile and improve the survivability of aircraft.

  12. General report IRS-literature 1965-1976

    International Nuclear Information System (INIS)

    Schulz, W.

    1976-12-01

    The Institut fuer Reaktorsicherheit der TUeV e.V. (IRS) is of central importance in matters of licensing. It was jointly founded in 1965 by the eleven TUeVs of the Federal Republic of Germany and West-Berlin, by the Germanischer Lloyd and the then Federal Ministry for Scientific Research. After 12 sucsessful years the IRS will terminate its activities on December 31st, 1976, and together with the Laboratorium fuer Reaktorregelung und Anlagensicherung (LRA) at the TU Munich, Garching, it will be from January 1st, 1977 onwards part of the Gesellschaft fuer Reaktorsicherheit (GRS) mbH, a newly founded corporation. The activities of IRS and LRA will be continued by the GRS starting from January 1st, 1977. All IRS' report series and information services listed in this report are thus running out. The new corporation will build up its publications on the basis of the experience gained by IRS and LRA. (orig.) [de

  13. Crystal growth and characterization of Ir-Te compounds

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhals, Philipp; Weber, Frank; Zocco, Diego; Adelmann, Peter; Merz, Michael; Wolf, Thomas; Kuntz, Sebastian; Grube, Kai [Karlsruhe Institute of Technology, Institute for Solid State Physics, Karlsruhe (Germany)

    2016-07-01

    IrTe{sub 2} is distinguished by a structural phase transition whose origin is not understood up to the present day. We grew crystals using the self-flux method starting from the reagents iridium and tellurium and got specimen with varying amounts of IrTe{sub 2} and Ir{sub 3}Te{sub 8}, analyzed by x-ray powder diffraction. We studied the transition near T = 280 K in magnetization measurements down to T = 1.8 K probing also for superconductivity, which was reported for intercalated samples. Results indicate that the structural transition happens over an extended range in temperature and superconductivity is absent in our samples. Ir{sub 3}Te{sub 8} is not studied to such an extent as IrTe{sub 2}. In previous publications a structural phase transition is reported. We characterized the transition by performing magnetization measurements and X-ray diffraction.

  14. The effect of test dose and first IR stimulation temperature on post-IR IRSL measurements of rock slices

    DEFF Research Database (Denmark)

    Liu, Jinfeng; Murray, Andrew; Sohbati, Reza

    2016-01-01

    lies close to the laboratory saturation levels only for higher first IR stimulation temperatures e.g. 200°C or 250°C. Our data confirm earlier suggestions based on sand-grain measurements that, for older sam-ples, accurate measurements close to saturation require that a higher first IR temperature...

  15. The univocal identification and safe dispensation of medicinal products across Europe – challenges and solution proposal

    Directory of Open Access Journals (Sweden)

    Stroetmann, Karl A.

    2017-12-01

    Full Text Available Problem: The Smart Open Services for European Patients (epSOS the exchange of electronic Patient Summaries and ePrescriptions between selected member states of the European Union (EU. This project basically solved the ‘communication’ or message transfer problem. However, it encountered a serious ‘delivery’ problem: the safe dispensation of a medicinal product noted in a prescription from a given country by a retail pharmacist in another country. The reason for this was that the specified medicine could in many instances not univocally be identified – the same name may identify a product with a different active ingredient, or the product with identical composition may carry a different name in the other country. If the prescribed medicine had not been authorised for marketing in the other country, information on its attributes may not be available. This rendered dispensation by the pharmacist impossible, even where substitution would, in principle, be allowed and possible.Objectives: This paper reports on the goal, activities and achievements of the openMedicine project towards development of a digital solution and its implementation to meet this identification and the resulting delivery challenge. European-wide and cross-Atlantic endeavours to enhance pharmacovigilance by being able to match adverse event reports filed under different drug names which provide, however, for the same active ingredient(s were developed upon. And the need for and benefits of being able to trace for clinical purposes, e.g. the longer-term treatment with the same active ingredient, even when the name of the prescribed medicine changed several times, were explored.Methodological approach: The openMedicine project was funded by the European Commission (EC on behalf of member states to analyse this European-wide problem. Work benefitted from the epSOS project and work by the European Medicines Agency (EMA, the USA Federal Drug Agency (FDA, and standard

  16. How complete is the information on preadmission psychotropic medications in inpatients with dementia? A comparison of hospital medical records with dispensing data.

    Science.gov (United States)

    Pisa, Federica Edith; Palese, Francesca; Romanese, Federico; Barbone, Fabio; Logroscino, Giancarlo; Riedel, Oliver

    2018-06-05

    Reliable information on preadmission medications is essential for inpatients with dementia, but its quality has hardly been evaluated. We assessed the completeness of information and factors associated with incomplete recording. We compared preadmission medications recorded in hospital electronic medical records (EMRs) with community-pharmacy dispensations in hospitalizations with discharge code for dementia at the University Hospital of Udine, Italy, 2012-2014. We calculated: (a) prevalence of omissions (dispensed medication not recorded in EMRs), additions (medication recorded in EMRs not dispensed), and discrepancies (any omission or addition); (b) multivariable logistic regression odds ratio, with 95% confidence interval (95% CI), of ≥1 omission. Among 2,777 hospitalizations, 86.1% had ≥1 discrepancy for any medication (Kappa 0.10) and 33.4% for psychotropics. When psychotropics were recorded in EMR, antipsychotics were added in 71.9% (antidepressants: 29.2%, antidementia agents: 48.2%); when dispensed, antipsychotics were omitted in 54.4% (antidepressants: 52.7%, antidementia agents: 41.5%). Omissions were 92% and twice more likely in patients taking 5 to 9 and ≥10 medications (vs. 0 to 4), 17% in patients with psychiatric disturbances (vs. none), and 41% with emergency admission (vs. planned). Psychotropics, commonly used in dementia, were often incompletely recorded. To enhance information completeness, both EMRs and dispensations should be used. Copyright © 2018 John Wiley & Sons, Ltd.

  17. Image registration of naval IR images

    Science.gov (United States)

    Rodland, Arne J.

    1996-06-01

    In a real world application an image from a stabilized sensor on a moving platform will not be 100 percent stabilized. There will always be a small unknown error in the stabilization due to factors such as dynamic deformations in the structure between sensor and reference Inertial Navigation Unit, servo inaccuracies, etc. For a high resolution imaging sensor this stabilization error causes the image to move several pixels in unknown direction between frames. TO be able to detect and track small moving objects from such a sensor, this unknown movement of the sensor image must be estimated. An algorithm that searches for land contours in the image has been evaluated. The algorithm searches for high contrast points distributed over the whole image. As long as moving objects in the scene only cover a small area of the scene, most of the points are located on solid ground. By matching the list of points from frame to frame, the movement of the image due to stabilization errors can be estimated and compensated. The point list is searched for points with diverging movement from the estimated stabilization error. These points are then assumed to be located on moving objects. Points assumed to be located on moving objects are gradually exchanged with new points located in the same area. Most of the processing is performed on the list of points and not on the complete image. The algorithm is therefore very fast and well suited for real time implementation. The algorithm has been tested on images from an experimental IR scanner. Stabilization errors were added artificially to the image such that the output from the algorithm could be compared with the artificially added stabilization errors.

  18. Automatic temperature computation for realistic IR simulation

    Science.gov (United States)

    Le Goff, Alain; Kersaudy, Philippe; Latger, Jean; Cathala, Thierry; Stolte, Nilo; Barillot, Philippe

    2000-07-01

    Polygon temperature computation in 3D virtual scenes is fundamental for IR image simulation. This article describes in detail the temperature calculation software and its current extensions, briefly presented in [1]. This software, called MURET, is used by the simulation workshop CHORALE of the French DGA. MURET is a one-dimensional thermal software, which accurately takes into account the material thermal attributes of three-dimensional scene and the variation of the environment characteristics (atmosphere) as a function of the time. Concerning the environment, absorbed incident fluxes are computed wavelength by wavelength, for each half an hour, druing 24 hours before the time of the simulation. For each polygon, incident fluxes are compsed of: direct solar fluxes, sky illumination (including diffuse solar fluxes). Concerning the materials, classical thermal attributes are associated to several layers, such as conductivity, absorption, spectral emissivity, density, specific heat, thickness and convection coefficients are taken into account. In the future, MURET will be able to simulate permeable natural materials (water influence) and vegetation natural materials (woods). This model of thermal attributes induces a very accurate polygon temperature computation for the complex 3D databases often found in CHORALE simulations. The kernel of MUET consists of an efficient ray tracer allowing to compute the history (over 24 hours) of the shadowed parts of the 3D scene and a library, responsible for the thermal computations. The great originality concerns the way the heating fluxes are computed. Using ray tracing, the flux received in each 3D point of the scene accurately takes into account the masking (hidden surfaces) between objects. By the way, this library supplies other thermal modules such as a thermal shows computation tool.

  19. β-Isocyanoalanine as an IR probe: comparison of vibrational dynamics between isonitrile and nitrile-derivatized IR probes.

    Science.gov (United States)

    Maj, Michał; Ahn, Changwoo; Kossowska, Dorota; Park, Kwanghee; Kwak, Kyungwon; Han, Hogyu; Cho, Minhaeng

    2015-05-07

    An infrared (IR) probe based on isonitrile (NC)-derivatized alanine 1 was synthesized and the vibrational properties of its NC stretching mode were investigated using FTIR and femtosecond IR pump-probe spectroscopy. It is found that the NC stretching mode is very sensitive to the hydrogen-bonding ability of solvent molecules. Moreover, its transition dipole strength is larger than that of nitrile (CN) in nitrile-derivatized IR probe 2. The vibrational lifetime of the NC stretching mode is found to be 5.5 ± 0.2 ps in both D2O and DMF solvents, which is several times longer than that of the azido (N3) stretching mode in azido-derivatized IR probe 3. Altogether these properties suggest that the NC group can be a very promising sensing moiety of IR probes for studying the solvation structure and dynamics of biomolecules.

  20. Efficiency potential of hot-drink dispensing machines in commercial catering; Effizienzpotenzial bei Heissgetraenkeautomaten in der Betriebsverpflegung

    Energy Technology Data Exchange (ETDEWEB)

    Grieder, T; Huser, A [Encontrol GmbH, Niederrohrdorf (Switzerland); Schmitz, R [Electrosuisse, Fehraltorf (Switzerland)

    2003-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) discusses the findings of a project that looked into the energy consumption of automatic hot-drink dispensing machines. The report presents the results of a survey made in Switzerland together with various manufacturers and operators of such machines that are used in the company refreshments sector. The survey provides important information on the current market situation, markets and market shares of individual operating companies as well as on machine technology and energy consumption. Also, obstacles to the improvement of energy efficiency in this area are looked at. Important savings that can be made in the operation of such machines are quoted. The report recommends that the results of a parallel survey of domestic coffee-making machines be taken note of and that effort should rather be concentrated in this area, where energy consumption at the national level is quoted as being around twice as high as for the commercial automatic hot-drink dispensing machines.