WorldWideScience

Sample records for ir cameras sold

  1. IR Camera Report for the 7 Day Production Test

    Energy Technology Data Exchange (ETDEWEB)

    Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-02-22

    The following report gives a summary of the IR camera performance results and data for the 7 day production run that occurred from 10 Sep 2015 thru 16 Sep 2015. During this production run our goal was to see how well the camera performed its task of monitoring the target window temperature with our improved alignment procedure and emissivity measurements. We also wanted to see if the increased shielding would be effective in protecting the camera from damage and failure.

  2. Image quality testing of assembled IR camera modules

    Science.gov (United States)

    Winters, Daniel; Erichsen, Patrik

    2013-10-01

    Infrared (IR) camera modules for the LWIR (8-12_m) that combine IR imaging optics with microbolometer focal plane array (FPA) sensors with readout electronics are becoming more and more a mass market product. At the same time, steady improvements in sensor resolution in the higher priced markets raise the requirement for imaging performance of objectives and the proper alignment between objective and FPA. This puts pressure on camera manufacturers and system integrators to assess the image quality of finished camera modules in a cost-efficient and automated way for quality control or during end-of-line testing. In this paper we present recent development work done in the field of image quality testing of IR camera modules. This technology provides a wealth of additional information in contrast to the more traditional test methods like minimum resolvable temperature difference (MRTD) which give only a subjective overall test result. Parameters that can be measured are image quality via the modulation transfer function (MTF) for broadband or with various bandpass filters on- and off-axis and optical parameters like e.g. effective focal length (EFL) and distortion. If the camera module allows for refocusing the optics, additional parameters like best focus plane, image plane tilt, auto-focus quality, chief ray angle etc. can be characterized. Additionally, the homogeneity and response of the sensor with the optics can be characterized in order to calculate the appropriate tables for non-uniformity correction (NUC). The technology can also be used to control active alignment methods during mechanical assembly of optics to high resolution sensors. Other important points that are discussed are the flexibility of the technology to test IR modules with different form factors, electrical interfaces and last but not least the suitability for fully automated measurements in mass production.

  3. Motorcycle detection and counting using stereo camera, IR camera, and microphone array

    Science.gov (United States)

    Ling, Bo; Gibson, David R. P.; Middleton, Dan

    2013-03-01

    Detection, classification, and characterization are the key to enhancing motorcycle safety, motorcycle operations and motorcycle travel estimation. Average motorcycle fatalities per Vehicle Mile Traveled (VMT) are currently estimated at 30 times those of auto fatalities. Although it has been an active research area for many years, motorcycle detection still remains a challenging task. Working with FHWA, we have developed a hybrid motorcycle detection and counting system using a suite of sensors including stereo camera, thermal IR camera and unidirectional microphone array. The IR thermal camera can capture the unique thermal signatures associated with the motorcycle's exhaust pipes that often show bright elongated blobs in IR images. The stereo camera in the system is used to detect the motorcyclist who can be easily windowed out in the stereo disparity map. If the motorcyclist is detected through his or her 3D body recognition, motorcycle is detected. Microphones are used to detect motorcycles that often produce low frequency acoustic signals. All three microphones in the microphone array are placed in strategic locations on the sensor platform to minimize the interferences of background noises from sources such as rain and wind. Field test results show that this hybrid motorcycle detection and counting system has an excellent performance.

  4. IR-camera methods for automotive brake system studies

    Science.gov (United States)

    Dinwiddie, Ralph B.; Lee, Kwangjin

    1998-03-01

    Automotive brake systems are energy conversion devices that convert kinetic energy into heat energy. Several mechanisms, mostly related to noise and vibration problems, can occur during brake operation and are often related to non-uniform temperature distribution on the brake disk. These problems are of significant cost to the industry and are a quality concern to automotive companies and brake system vendors. One such problem is thermo-elastic instabilities in brake system. During the occurrence of these instabilities several localized hot spots will form around the circumferential direction of the brake disk. The temperature distribution and the time dependence of these hot spots, a critical factor in analyzing this problem and in developing a fundamental understanding of this phenomenon, were recorded. Other modes of non-uniform temperature distributions which include hot banding and extreme localized heating were also observed. All of these modes of non-uniform temperature distributions were observed on automotive brake systems using a high speed IR camera operating in snap-shot mode. The camera was synchronized with the rotation of the brake disk so that the time evolution of hot regions could be studied. This paper discusses the experimental approach in detail.

  5. Optimization of grate combustion by means of an IR camera. Final report; Optimering af risteforbraending IR-kamera. Slut rapport

    Energy Technology Data Exchange (ETDEWEB)

    Didriksen, H.; Jensen, Joergen Peter; Hansen, Joergen (DONG Energy, Fredericia (Denmark)); Clausen, Soennik; Larsen, Henning (Technical Univ. of Denmark, Risoe National Lab. for Sustainable Energy, Roskilde (Denmark))

    2010-09-15

    The target of the project has been to improve the control and regulation of grate-fired straw boilers by involving measuring signals from a specially developed IR camera in a new regulation concept. The project was carried out with the straw boiler at the Avedoere power station. The conclusion has been that it is a very demanding task to develop an IR camera, including software, which must function as a process measuring device for continuous on-line measuring under very demanding conditions in a straw fired boiler. The result showed that this was not possible within the framework of this project. The developed camera has on the other hand proved to be very well suited for measuring campaigns, where the camera is ''manned''/continuously monitored. (Energy 11)

  6. About possibility of temperature trace observing on the human skin using commercially available IR camera

    Science.gov (United States)

    Trofimov, Vyacheslav A.; Trofimov, Vladislav V.; Shestakov, Ivan L.; Blednov, Roman G.

    2016-09-01

    One of urgent security problems is a detection of objects placed inside the human body. Obviously, for safety reasons one cannot use X-rays for such object detection widely and often. Three years ago, we have demonstrated principal possibility to see a temperature trace, induced by food eating or water drinking, on the human body skin by using a passive THz camera. However, this camera is very expensive. Therefore, for practice it will be very convenient if one can use the IR camera for this purpose. In contrast to passive THz camera using, the IR camera does not allow to see the object under clothing, if an image, produced by this camera, is used directly. Of course, this is a big disadvantage for a security problem solution based on the IR camera using. To overcome this disadvantage we develop novel approach for computer processing of IR camera images. It allows us to increase a temperature resolution of IR camera as well as increasing of human year effective susceptibility. As a consequence of this, a possibility for seeing of a human body temperature changing through clothing appears. We analyze IR images of a person, which drinks water and eats chocolate. We follow a temperature trace on human body skin, caused by changing of temperature inside the human body. Some experiments were made with measurements of a body temperature covered by T-shirt. Shown results are very important for the detection of forbidden objects, cancelled inside the human body, by using non-destructive control without using X-rays.

  7. A new high-speed IR camera system

    Science.gov (United States)

    Travis, Jeffrey W.; Shu, Peter K.; Jhabvala, Murzy D.; Kasten, Michael S.; Moseley, Samuel H.; Casey, Sean C.; Mcgovern, Lawrence K.; Luers, Philip J.; Dabney, Philip W.; Kaipa, Ravi C.

    1994-01-01

    A multi-organizational team at the Goddard Space Flight Center is developing a new far infrared (FIR) camera system which furthers the state of the art for this type of instrument by the incorporating recent advances in several technological disciplines. All aspects of the camera system are optimized for operation at the high data rates required for astronomical observations in the far infrared. The instrument is built around a Blocked Impurity Band (BIB) detector array which exhibits responsivity over a broad wavelength band and which is capable of operating at 1000 frames/sec, and consists of a focal plane dewar, a compact camera head electronics package, and a Digital Signal Processor (DSP)-based data system residing in a standard 486 personal computer. In this paper we discuss the overall system architecture, the focal plane dewar, and advanced features and design considerations for the electronics. This system, or one derived from it, may prove useful for many commercial and/or industrial infrared imaging or spectroscopic applications, including thermal machine vision for robotic manufacturing, photographic observation of short-duration thermal events such as combustion or chemical reactions, and high-resolution surveillance imaging.

  8. Modeling and Compensating Temperature-Dependent Non-Uniformity Noise in IR Microbolometer Cameras

    Directory of Open Access Journals (Sweden)

    Alejandro Wolf

    2016-07-01

    Full Text Available Images rendered by uncooled microbolometer-based infrared (IR cameras are severely degraded by the spatial non-uniformity (NU noise. The NU noise imposes a fixed-pattern over the true images, and the intensity of the pattern changes with time due to the temperature instability of such cameras. In this paper, we present a novel model and a compensation algorithm for the spatial NU noise and its temperature-dependent variations. The model separates the NU noise into two components: a constant term, which corresponds to a set of NU parameters determining the spatial structure of the noise, and a dynamic term, which scales linearly with the fluctuations of the temperature surrounding the array of microbolometers. We use a black-body radiator and samples of the temperature surrounding the IR array to offline characterize both the constant and the temperature-dependent NU noise parameters. Next, the temperature-dependent variations are estimated online using both a spatially uniform Hammerstein-Wiener estimator and a pixelwise least mean squares (LMS estimator. We compensate for the NU noise in IR images from two long-wave IR cameras. Results show an excellent NU correction performance and a root mean square error of less than 0.25 ∘ C, when the array’s temperature varies by approximately 15 ∘ C.

  9. Automated recognition and tracking of aerosol threat plumes with an IR camera pod

    Science.gov (United States)

    Fauth, Ryan; Powell, Christopher; Gruber, Thomas; Clapp, Dan

    2012-06-01

    Protection of fixed sites from chemical, biological, or radiological aerosol plume attacks depends on early warning so that there is time to take mitigating actions. Early warning requires continuous, autonomous, and rapid coverage of large surrounding areas; however, this must be done at an affordable cost. Once a potential threat plume is detected though, a different type of sensor (e.g., a more expensive, slower sensor) may be cued for identification purposes, but the problem is to quickly identify all of the potential threats around the fixed site of interest. To address this problem of low cost, persistent, wide area surveillance, an IR camera pod and multi-image stitching and processing algorithms have been developed for automatic recognition and tracking of aerosol plumes. A rugged, modular, static pod design, which accommodates as many as four micro-bolometer IR cameras for 45deg to 180deg of azimuth coverage, is presented. Various OpenCV1 based image-processing algorithms, including stitching of multiple adjacent FOVs, recognition of aerosol plume objects, and the tracking of aerosol plumes, are presented using process block diagrams and sample field test results, including chemical and biological simulant plumes. Methods for dealing with the background removal, brightness equalization between images, and focus quality for optimal plume tracking are also discussed.

  10. Design and Calibration of a Dispersive Imaging Spectrometer Adaptor for a Fast IR Camera on NSTX-U

    Science.gov (United States)

    Reksoatmodjo, Richard; Gray, Travis; Princeton Plasma Physics Laboratory Team

    2017-10-01

    A dispersive spectrometer adaptor was designed, constructed and calibrated for use on a fast infrared camera employed to measure temperatures on the lower divertor tiles of the NSTX-U tokamak. This adaptor efficiently and evenly filters and distributes long-wavelength infrared photons between 8.0 and 12.0 microns across the 128x128 pixel detector of the fast IR camera. By determining the width of these separated wavelength bands across the camera detector, and then determining the corresponding average photon count for each photon wavelength, a very accurate measurement of the temperature, and thus heat flux, of the divertor tiles can be calculated using Plank's law. This approach of designing an exterior dispersive adaptor for the fast IR camera allows accurate temperature measurements to be made of materials with unknown emissivity. Further, the relative simplicity and affordability of this adaptor design provides an attractive option over more expensive, slower, dispersive IR camera systems. This work was made possible by funding from the Department of Energy for the Summer Undergraduate Laboratory Internship (SULI) program. This work is supported by the US DOE Contract No. DE-AC02-09CH11466.

  11. HDR 192Ir source speed measurements using a high speed video camera

    International Nuclear Information System (INIS)

    Fonseca, Gabriel P.; Viana, Rodrigo S. S.; Yoriyaz, Hélio; Podesta, Mark; Rubo, Rodrigo A.; Sales, Camila P. de; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Purpose: The dose delivered with a HDR 192 Ir afterloader can be separated into a dwell component, and a transit component resulting from the source movement. The transit component is directly dependent on the source speed profile and it is the goal of this study to measure accurate source speed profiles. Methods: A high speed video camera was used to record the movement of a 192 Ir source (Nucletron, an Elekta company, Stockholm, Sweden) for interdwell distances of 0.25–5 cm with dwell times of 0.1, 1, and 2 s. Transit dose distributions were calculated using a Monte Carlo code simulating the source movement. Results: The source stops at each dwell position oscillating around the desired position for a duration up to (0.026 ± 0.005) s. The source speed profile shows variations between 0 and 81 cm/s with average speed of ∼33 cm/s for most of the interdwell distances. The source stops for up to (0.005 ± 0.001) s at nonprogrammed positions in between two programmed dwell positions. The dwell time correction applied by the manufacturer compensates the transit dose between the dwell positions leading to a maximum overdose of 41 mGy for the considered cases and assuming an air-kerma strength of 48 000 U. The transit dose component is not uniformly distributed leading to over and underdoses, which is within 1.4% for commonly prescribed doses (3–10 Gy). Conclusions: The source maintains its speed even for the short interdwell distances. Dose variations due to the transit dose component are much lower than the prescribed treatment doses for brachytherapy, although transit dose component should be evaluated individually for clinical cases

  12. Lane Departure System Design using with IR Camera for Night-time Road Conditions

    Directory of Open Access Journals (Sweden)

    Osman Onur Akırmak

    2015-02-01

    Full Text Available Today, one of the largest areas of research and development in the automobile industry is road safety. Many deaths and injuries occur every year on public roads from accidents caused by sleepy drivers, that technology could have been used to prevent. Lane detection at night-time is an important issue in driving assistance systems. This paper deals with vision-based lane detection and tracking at night-time. This project consists of a research and development of an algorithm for automotive systems to detect the departure of vehicle from out of lane. Once the situation is detected, a warning is issued to the driver with sound and visual message through “Head Up Display” (HUD system. The lane departure is detected through the images obtained from a single IR camera, which identifies the departure at a satisfactory accuracy via improved quality of video stream. Our experimental results and accuracy evaluation show that our algorithm has good precision and our detecting method is suitable for night-time road conditions.

  13. Measurements of temperature of the tungsten hexa-ethoxide pyrolysis flame using IR camera

    CSIR Research Space (South Africa)

    Mudau, AE

    2010-09-01

    Full Text Available In laser pyrolysis, temperature measurement and control plays a vital role during the development of nanoparticles. Authors present the results of temperature measurements using infrared camera on a tungsten hexa-ethoxide pyrolysis flame used...

  14. Using VIS/NIR and IR spectral cameras for detecting and separating crime scene details

    Science.gov (United States)

    Kuula, Jaana; Pölönen, Ilkka; Puupponen, Hannu-Heikki; Selander, Tuomas; Reinikainen, Tapani; Kalenius, Tapani; Saari, Heikki

    2012-06-01

    Detecting invisible details and separating mixed evidence is critical for forensic inspection. If this can be done reliably and fast at the crime scene, irrelevant objects do not require further examination at the laboratory. This will speed up the inspection process and release resources for other critical tasks. This article reports on tests which have been carried out at the University of Jyväskylä in Finland together with the Central Finland Police Department and the National Bureau of Investigation for detecting and separating forensic details with hyperspectral technology. In the tests evidence was sought after at an assumed violent burglary scene with the use of VTT's 500-900 nm wavelength VNIR camera, Specim's 400- 1000 nm VNIR camera, and Specim's 1000-2500 nm SWIR camera. The tested details were dried blood on a ceramic plate, a stain of four types of mixed and absorbed blood, and blood which had been washed off a table. Other examined details included untreated latent fingerprints, gunshot residue, primer residue, and layered paint on small pieces of wood. All cameras could detect visible details and separate mixed paint. The SWIR camera could also separate four types of human and animal blood which were mixed in the same stain and absorbed into a fabric. None of the cameras could however detect primer residue, untreated latent fingerprints, or blood that had been washed off. The results are encouraging and indicate the need for further studies. The results also emphasize the importance of creating optimal imaging conditions into the crime scene for each kind of subjects and backgrounds.

  15. Cryogenic solid Schmidt camera as a base for future wide-field IR systems

    Science.gov (United States)

    Yudin, Alexey N.

    2011-11-01

    Work is focused on study of capability of solid Schmidt camera to serve as a wide-field infrared lens for aircraft system with whole sphere coverage, working in 8-14 um spectral range, coupled with spherical focal array of megapixel class. Designs of 16 mm f/0.2 lens with 60 and 90 degrees sensor diagonal are presented, their image quality is compared with conventional solid design. Achromatic design with significantly improved performance, containing enclosed soft correcting lens behind protective front lens is proposed. One of the main goals of the work is to estimate benefits from curved detector arrays in 8-14 um spectral range wide-field systems. Coupling of photodetector with solid Schmidt camera by means of frustrated total internal reflection is considered, with corresponding tolerance analysis. The whole lens, except front element, is considered to be cryogenic, with solid Schmidt unit to be flown by hydrogen for improvement of bulk transmission.

  16. An assessment of surface emissivity variation effects on plasma uniformity analysis using IR cameras

    Science.gov (United States)

    Greenhalgh, Abigail; Showers, Melissa; Biewer, Theodore

    2017-10-01

    The Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device operating at Oak Ridge National Laboratory (ORNL). Its purpose is to test plasma source and heating concepts for the planned Material Plasma Exposure eXperiment (MPEX), which has the mission to test the plasma-material interactions under fusion reactor conditions. In this device material targets will be exposed to high heat fluxes (>10 MW/m2). To characterize the heat fluxes to the target a IR thermography system is used taking up to 432 frames per second videos. The data is analyzed to determine the surface temperature on the target in specific regions of interest. The IR analysis has indicated a low level of plasma uniformity; the plasma often deposits more heat to the edge of the plate than the center. An essential parameter for IR temperature calculation is the surface emissivity of the plate (stainless steel). A study has been performed to characterize the variation in the surface emissivity of the plate as its temperature changes and its surface finish is modified by plasma exposure.

  17. Decoupling Intensity Radiated by the Emitter in Distance Estimation from Camera to IR Emitter

    Directory of Open Access Journals (Sweden)

    Carlos Andrés Luna Vázquez

    2013-05-01

    Full Text Available Various models using radiometric approach have been proposed to solve the problem of estimating the distance between a camera and an infrared emitter diode (IRED. They depend directly on the radiant intensity of the emitter, set by the IRED bias current. As is known, this current presents a drift with temperature, which will be transferred to the distance estimation method. This paper proposes an alternative approach to remove temperature drift in the distance estimation method by eliminating the dependence on radiant intensity. The main aim was to use the relative accumulated energy together with other defined models, such as the zeroth-frequency component of the FFT of the IRED image and the standard deviation of pixel gray level intensities in the region of interest containing the IRED image. By using the abovementioned models, an expression free of IRED radiant intensity was obtained. Furthermore, the final model permitted simultaneous estimation of the distance between the IRED and the camera and the IRED orientation angle. The alternative presented in this paper gave a 3% maximum relative error over a range of distances up to 3 m.

  18. Infrared Imaging Camera Final Report CRADA No. TC02061.0

    Energy Technology Data Exchange (ETDEWEB)

    Roos, E. V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Nebeker, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-08

    This was a collaborative effort between the University of California, Lawrence Livermore National Laboratory (LLNL) and Cordin Company (Cordin) to enhance the U.S. ability to develop a commercial infrared camera capable of capturing high-resolution images in a l 00 nanoseconds (ns) time frame. The Department of Energy (DOE), under an Initiative for Proliferation Prevention (IPP) project, funded the Russian Federation Nuclear Center All-Russian Scientific Institute of Experimental Physics (RFNC-VNIIEF) in Sarov. VNIIEF was funded to develop a prototype commercial infrared (IR) framing camera and to deliver a prototype IR camera to LLNL. LLNL and Cordin were partners with VNIIEF on this project. A prototype IR camera was delivered by VNIIEF to LLNL in December 2006. In June of 2007, LLNL and Cordin evaluated the camera and the test results revealed that the camera exceeded presently available commercial IR cameras. Cordin believes that the camera can be sold on the international market. The camera is currently being used as a scientific tool within Russian nuclear centers. This project was originally designated as a two year project. The project was not started on time due to changes in the IPP project funding conditions; the project funding was re-directed through the International Science and Technology Center (ISTC), which delayed the project start by over one year. The project was not completed on schedule due to changes within the Russian government export regulations. These changes were directed by Export Control regulations on the export of high technology items that can be used to develop military weapons. The IR camera was on the list that export controls required. The ISTC and Russian government, after negotiations, allowed the delivery of the camera to LLNL. There were no significant technical or business changes to the original project.

  19. Cameras in mobile phones

    Science.gov (United States)

    Nummela, Ville; Viinikanoja, Jarkko; Alakarhu, Juha

    2006-04-01

    One of the fastest growing markets in consumer markets today are camera phones. During past few years total volume has been growing fast and today millions of mobile phones with camera will be sold. At the same time resolution and functionality of the cameras has been growing from CIF towards DSC level. From camera point of view the mobile world is an extremely challenging field. Cameras should have good image quality but in small size. They also need to be reliable and their construction should be suitable for mass manufacturing. All components of the imaging chain should be well optimized in this environment. Image quality and usability are the most important parameters to user. The current trend of adding more megapixels to cameras and at the same time using smaller pixels is affecting both. On the other hand reliability and miniaturization are key drivers for product development as well as the cost. In optimized solution all parameters are in balance but the process of finding the right trade-offs is not an easy task. In this paper trade-offs related to optics and their effects to image quality and usability of cameras are discussed. Key development areas from mobile phone camera point of view are also listed.

  20. Monitoring of oil leakage from a ship propulsion system using IR camera and wavelet analysis for prevention of health and ecology risks and engine faults

    Energy Technology Data Exchange (ETDEWEB)

    Soda, J.; Beros, S. [University of Split (Croatia). Faculty of Electrical Engineering, Mechanical Engineering and Naval Architecture; Antonic, R.; Vujovic, I. [University of Split (Croatia) Maritime Faculty; Kuzmanic, I.

    2009-03-15

    It is a well known fact that oil leakage from ship diesel engines is harmful both for the environment and the ship engine and therefore has to be observed and alarmed. The present paper proposes a system for overcoming described problems by installing a computer vision system. The used algorithm of pattern recognition system is based on the use of wavelet structures. Additionally, one of the problems in the system is the compensation of camera movements due to engine vibration. The compensation part of the computer vision solution is used to improve position determination. The position determination is improved more that 300 % when using farras wavelets. (Abstract Copyright [2009], Wiley Periodicals, Inc.) [German] (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  1. A Physical Model-based Correction for Charge Traps in the Hubble Space Telescope ’s Wide Field Camera 3 Near-IR Detector and Its Applications to Transiting Exoplanets and Brown Dwarfs

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yifan; Apai, Dániel; Schneider, Glenn [Department of Astronomy/Steward Observatory, The University of Arizona, 933 N. Cherry Avenue, Tucson, AZ 85721 (United States); Lew, Ben W. P., E-mail: yzhou@as.arizona.edu [Department of Planetary Science/Lunar and Planetary Laboratory, The University of Arizona, 1640 E. University Boulevard, Tucson, AZ 85718 (United States)

    2017-06-01

    The Hubble Space Telescope Wide Field Camera 3 (WFC3) near-IR channel is extensively used in time-resolved observations, especially for transiting exoplanet spectroscopy as well as brown dwarf and directly imaged exoplanet rotational phase mapping. The ramp effect is the dominant source of systematics in the WFC3 for time-resolved observations, which limits its photometric precision. Current mitigation strategies are based on empirical fits and require additional orbits to help the telescope reach a thermal equilibrium . We show that the ramp-effect profiles can be explained and corrected with high fidelity using charge trapping theories. We also present a model for this process that can be used to predict and to correct charge trap systematics. Our model is based on a very small number of parameters that are intrinsic to the detector. We find that these parameters are very stable between the different data sets, and we provide best-fit values. Our model is tested with more than 120 orbits (∼40 visits) of WFC3 observations and is proved to be able to provide near photon noise limited corrections for observations made with both staring and scanning modes of transiting exoplanets as well as for starting-mode observations of brown dwarfs. After our model correction, the light curve of the first orbit in each visit has the same photometric precision as subsequent orbits, so data from the first orbit no longer need to be discarded. Near-IR arrays with the same physical characteristics (e.g., JWST/NIRCam ) may also benefit from the extension of this model if similar systematic profiles are observed.

  2. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, Ul; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is replaceably mounted in the ray inlet opening of the camera, while the others are placed on separate supports. Supports are swingably mounted upon a column one above the other

  3. Gamma camera

    International Nuclear Information System (INIS)

    Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    The design of a collimation system for a gamma camera for use in nuclear medicine is described. When used with a 2-dimensional position sensitive radiation detector, the novel system can produce superior images than conventional cameras. The optimal thickness and positions of the collimators are derived mathematically. (U.K.)

  4. Picosecond camera

    International Nuclear Information System (INIS)

    Decroisette, Michel

    A Kerr cell activated by infrared pulses of a model locked Nd glass laser, acts as an ultra-fast and periodic shutter, with a few p.s. opening time. Associated with a S.T.L. camera, it gives rise to a picosecond camera allowing us to study very fast effects [fr

  5. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, U.; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is mounted in the ray inlet opening of the camera, while the others are placed on separate supports. The supports are swingably mounted upon a column one above the other through about 90 0 to a collimator exchange position. Each of the separate supports is swingable to a vertically aligned position, with limiting of the swinging movement and positioning of the support at the desired exchange position. The collimators are carried on the supports by means of a series of vertically disposed coil springs. Projections on the camera are movable from above into grooves of the collimator at the exchange position, whereupon the collimator is turned so that it is securely prevented from falling out of the camera head

  6. Radioactivity in bottled waters sold in Mexico

    International Nuclear Information System (INIS)

    Davila Rangel, J.I.; Lopez del Rio, H.; Mireles Garcia, F.; Quirino Torres, L.L.; Villalba, M.L.; Colmenero Sujo, L.; Montero Cabrera, M.E.

    2002-01-01

    Measurements of gross alpha and beta activities were made on 21 domestic and international brands of bottled (purified and mineral) water sold in the Mexican market to assess its radiological quality. Alpha and beta activities were determined using a liquid-scintillation detector with pulse-shape analysis feature. All the purified water had values of beta activity lower than the limit for potable drinking water (1.0 Bq/l), while three brands surpassed the limit of alpha activity (0.1 Bq/l). The limit for alpha radioactivity content was exceed by three mineral waters; the results show a correlation between radioactivity content and mineral salts, which are related with the origin and treatment of the waters

  7. HEDONIC ANALYSIS OF CELL PHONES SOLD WITH POST-PAID SERVICE PLANS IN BRAZIL

    Directory of Open Access Journals (Sweden)

    Cláudio R. Lucinda

    2012-07-01

    Full Text Available The aim of this paper is to analyze the determining factors for the pricing of handsets sold with service plans, using the hedonic price method. This was undertaken by building a database comprising 48 handset models, under nine different service plans, over a period of 53 weeks in 2008, and resulted in 27 different attributes and a total number of nearly 300,000 data registers. The results suggest that the value of monthly subscriptions and calling minutes are important to explain the prices of handsets. Furthermore, both the physical volume and number of megapixels of a camera had an effect on the prices. The bigger the handset, the cheaper it becomes, and the more megapixels a camera phone has, the more expensive it becomes. Additionally, it was found that in 2008 Brazilian phone companies were subsidizing enabled data connection handsets.

  8. Scintillating camera

    International Nuclear Information System (INIS)

    Vlasbloem, H.

    1976-01-01

    The invention relates to a scintillating camera and in particular to an apparatus for determining the position coordinates of a light pulse emitting point on the anode of an image intensifier tube which forms part of a scintillating camera, comprising at least three photomultipliers which are positioned to receive light emitted by the anode screen on their photocathodes, circuit means for processing the output voltages of the photomultipliers to derive voltages that are representative of the position coordinates; a pulse-height discriminator circuit adapted to be fed with the sum voltage of the output voltages of the photomultipliers for gating the output of the processing circuit when the amplitude of the sum voltage of the output voltages of the photomultipliers lies in a predetermined amplitude range, and means for compensating the distortion introduced in the image on the anode screen

  9. Gamma camera

    International Nuclear Information System (INIS)

    Reiss, K.H.; Kotschak, O.; Conrad, B.

    1976-01-01

    A gamma camera with a simplified setup as compared with the state of engineering is described permitting, apart from good localization, also energy discrimination. Behind the usual vacuum image amplifier a multiwire proportional chamber filled with trifluorine bromium methane is connected in series. Localizing of the signals is achieved by a delay line, energy determination by means of a pulse height discriminator. With the aid of drawings and circuit diagrams, the setup and mode of operation are explained. (ORU) [de

  10. Gamma camera

    International Nuclear Information System (INIS)

    Berninger, W.H.

    1975-01-01

    The light pulse output of a scintillator, on which incident collimated gamma rays impinge, is detected by an array of photoelectric tubes each having a convexly curved photocathode disposed in close proximity to the scintillator. Electronic circuitry connected to outputs of the phototubes develops the scintillation event position coordinate electrical signals with good linearity and with substantial independence of the spacing between the scintillator and photocathodes so that the phototubes can be positioned as close to the scintillator as is possible to obtain less distortion in the field of view and improved spatial resolution as compared to conventional planar photocathode gamma cameras

  11. Radioisotope camera

    International Nuclear Information System (INIS)

    Tausch, L.M.; Kump, R.J.

    1978-01-01

    The electronic ciruit corrects distortions caused by the distance between the individual photomultiplier tubes of the multiple radioisotope camera on one hand and between the tube configuration and the scintillator plate on the other. For this purpose the transmission characteristics of the nonlinear circuits are altered as a function of the energy of the incident radiation. By this means the threshold values between lower and higher amplification are adjusted to the energy level of each scintillation. The correcting circuit may be used for any number of isotopes to be measured. (DG) [de

  12. 29 CFR 779.333 - Goods sold for use as raw materials in other products.

    Science.gov (United States)

    2010-07-01

    ... are not considered sold for resale if sold for general industrial or commercial uses, such as coal for... stores or meat markets in cooling and preserving groceries and meat to be sold. Similarly, ice used for...

  13. Results with the UKIRT infrared camera

    International Nuclear Information System (INIS)

    Mclean, I.S.

    1987-01-01

    Recent advances in focal plane array technology have made an immense impact on infrared astronomy. Results from the commissioning of the first infrared camera on UKIRT (the world's largest IR telescope) are presented. The camera, called IRCAM 1, employs the 62 x 58 InSb DRO array from SBRC in an otherwise general purpose system which is briefly described. Several imaging modes are possible including staring, chopping and a high-speed snapshot mode. Results to be presented include the first true high resolution images at IR wavelengths of the entire Orion nebula

  14. The effects of acute administration of Chinese aphrodisiacs sold in ...

    African Journals Online (AJOL)

    The effects of acute administration of Chinese aphrodisiacs sold in Blantyre City on sperm characteristics and fertility profile in guinea pigs. ... However, selling of these drugs seems not to be well regulated. Probably the aphrodisiacs that are ...

  15. Bacteriological quality of bottled water sold on the Ghanaian market ...

    African Journals Online (AJOL)

    Bacteriological quality of bottled water sold on the Ghanaian market. ... Consumption of bottled water is increasing rapidly in developing countries especially among ... limits set by WHO guidelines and therefore safe for human consumption.

  16. Gamma camera

    International Nuclear Information System (INIS)

    Conrad, B.; Heinzelmann, K.G.

    1975-01-01

    A gamma camera is described which obviates the distortion of locating signals generally caused by the varied light conductive capacities of the light conductors in that the flow of light through each light conductor may be varied by means of a shutter. A balancing of the flow of light through each of the individual light conductors, in effect, collective light conductors may be balanced on the basis of their light conductive capacities or properties, so as to preclude a distortion of the locating signals caused by the varied light conductive properties of the light conductors. Each light conductor has associated therewith two, relative to each other, independently adjustable shutters, of which one forms a closure member and the other an adjusting shutter. In this embodiment of the invention it is thus possible to block all of the light conductors leading to a photoelectric transducer, with the exception of those light conductors which are to be balanced. The balancing of the individual light conductors may then be obtained on the basis of the output signals of the photoelectric transducer. (auth)

  17. Scintillation camera

    International Nuclear Information System (INIS)

    Zioni, J.; Klein, Y.; Inbar, D.

    1975-01-01

    The scintillation camera is to make pictures of the density distribution of radiation fields created by the injection or administration radioactive medicaments into the body of the patient. It contains a scintillation crystal, several photomultipliers and computer circuits to obtain an analytical function at the exits of the photomultiplier which is dependent on the position of the scintillations at the time in the crystal. The scintillation crystal is flat and spatially corresponds to the production site of radiation. The photomultipliers form a pattern whose basic form consists of at least three photomultipliers. They are assigned to at least two crossing parallel series groups where a vertical running reference axis in the crystal plane belongs to each series group. The computer circuits are each assigned to a reference axis. Each series of a series group assigned to one of the reference axes in the computer circuit has an adder to produce a scintillation dependent series signal. Furthermore, the projection of the scintillation on this reference axis is calculated. A series signal is used for this which originates from a series chosen from two neighbouring photomultiplier series of this group. The scintillation must have appeared between these chosen series. They are termed as basic series. The photomultiplier can be arranged hexagonally or rectangularly. (GG/LH) [de

  18. Ge Quantum Dot Infrared Imaging Camera, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Luna Innovations Incorporated proposes to develop a high performance Ge quantum dots-based infrared (IR) imaging camera on Si substrate. The high sensitivity, large...

  19. Students' Framing of Laboratory Exercises Using Infrared Cameras

    Science.gov (United States)

    Haglund, Jesper; Jeppsson, Fredrik; Hedberg, David; Schönborn, Konrad J.

    2015-01-01

    Thermal science is challenging for students due to its largely imperceptible nature. Handheld infrared cameras offer a pedagogical opportunity for students to see otherwise invisible thermal phenomena. In the present study, a class of upper secondary technology students (N = 30) partook in four IR-camera laboratory activities, designed around the…

  20. Ethics and quality assessment of cowpea grains sold in southern ...

    African Journals Online (AJOL)

    The study examined the supply side of cowpea markets in two states of Nigeria. Specifically, quality status; grades of cowpea grains sold and effect of ethics on sales, quality and price were determined. A multi-stage sampling technique was used to select four hundred cowpea grain sellers in the study areas. Questionnaire ...

  1. Prevalence of intestinal parasites in vegetables sold in major ...

    African Journals Online (AJOL)

    Studies were carried out in Ibadan City, South-West Nigeria between March and June 2011, to determine the prevalence of intestinal parasites in vegetables sold in various markets within the city. Fifty samples each of 5 different vegetable types, Cabbage (Brassica deracea), Lettuce (Lactus sativa), Carrot (Daucus carota), ...

  2. Occurrence of Clostridium perfringens in sausages sold in Meknes ...

    African Journals Online (AJOL)

    In Morocco, the consumption of meat products has experienced a sharp increase in recent years despite the presence of pathogenic bacteria due to hygiene failure. The present study was designed to determine the prevalence of Clostridium perfringens in sausages sold in Meknes city (Morocco) and to study the different ...

  3. Parasitic Contamination of Fruits and Vegetables Sold at Kaduna ...

    African Journals Online (AJOL)

    The safety of fruits and vegetables sold in Kaduna metropolis, Nigeria for consumption was assessed with respect to their contamination by Ova and Cysts of parasites. Out of 320 samples of seven (7) varieties of vegetables and fruits examined from three different markets in Kaduna metropolis, 45 (14.00%) were positive ...

  4. Quality assessment of sachet and bottled water sold in Gboko ...

    African Journals Online (AJOL)

    The quality of selected sachet and bottled water produced and sold within Gboko town, Benue State was investigated to determine their Shelf life. Eight brands of sachet water and four brands of bottled water samples were collected from different manufacturers within 24 hours and stored at ambient temperature.

  5. Medicinal plants sold at the El Rio Market, Camaguey, Cuba

    NARCIS (Netherlands)

    Godinez-Caraballo, D.; Volpato, G.

    2008-01-01

    Information regarding medicinal plants sold in the El Rio Market, Camaguey, Cuba, revealed 184 species belonging to 69 vascular plant families. The most important family was Fabaceae s.l. with 13 species, followed by Lamiaceae with 12, and Asteraceae with 8. More than 90 general medicinal

  6. Parasites and Morphometric Indices of Frozen Fish Sold in Nsukka ...

    African Journals Online (AJOL)

    The parasites and morphometric indices of frozen fish sold in Nsukka Urban Market in Nsukka Local Government Area of Enugu State, Nigeria were investigated between June and December 2008 to determine the parasite prevalence, mean intensity and abundance and some morphometric indices associated with ...

  7. Quality of Artesunate Tablets Sold in Pharmacies in Kumasi, Ghana ...

    African Journals Online (AJOL)

    Purpose: The study was carried out to evaluate the quality of artesunate tablets sold in retail and wholesale pharmacies in Kumasi, Ghana. In particular, the study sought to ascertain the presence or otherwise of counterfeit artesunate tablets in Kumasi. Method: Artesunate tablets were purchased from pharmacies in Kumasi ...

  8. quality and safety characteristics of cassava crisps sold in urban

    African Journals Online (AJOL)

    ACSS

    QUALITY AND SAFETY CHARACTERISTICS OF CASSAVA CRISPS SOLD IN. URBAN KENYA. G.O. ABONG', S.I. SHIBAIRO, ... This study sought to characterise the quality and safety in terms of cyanide levels of cassava crisps ... Crantz) to food security and incomes for rural communities in sub-Saharan Africa, cannot be.

  9. Microbial Load of Some Medicinal Plants Sold in Some Local ...

    African Journals Online (AJOL)

    Microbial Load of Some Medicinal Plants Sold in Some Local Markets in Abeokuta, Nigeria. I MacDonald, S Omonigho, J Erhabor, H Efijuemue. Abstract. Purpose: To evaluate the microbial load on 17 randomly selected plant samples from 60 ethnobotanically collected medicinal plants from five local markets in Abeokuta, ...

  10. The mineral composition of five insects as sold for human ...

    African Journals Online (AJOL)

    Edible insects have been proposed as an alternative protein source that is economically and environmentally preferable to livestock, and certain species may be high in nutrients that benefit human health. We present data describing the mineral content of five edible insects as sold in South Africa and Zimbabwe. We report ...

  11. Quality characteristics of commercial bottled water sold in Owerri ...

    African Journals Online (AJOL)

    The quality characteristics of commercial bottled water sold in Owerri, Imo State, Nigeria were investigated to determine their physical, chemical and bacteriological content. The four brands of bottled water investigated were Mevok ®, Ozonized April ®, Lacrystal ® and Eva ®. The mean turbidity value of all the samples were ...

  12. Microbiological quality of commercially available poultry feeds sold ...

    African Journals Online (AJOL)

    Food poisoning and infection by bacterial and fungal genera pose obvious health threat to both animals and humans. Pfizer, Guinea, Extra, Top, NOM and Master brands of feed sold in Owerri Metropolis were analysed for their bacterial and fungal quality. The genera of bacteria and fungi isolated and their percentage ...

  13. Potassium bromate content of some baked breads sold in Kano ...

    African Journals Online (AJOL)

    Background: Potassium bromate is an additive used by some bakers to make the bread rise rapidly, create a good texture in the finished product and to give bulkiness to the dough. Objective: The main objective of this work was to assess the potassium bromate residues of some baked breads sold in some selected local ...

  14. Foods and Beverages Sold Outside the School Meals Program

    Science.gov (United States)

    Foods and Beverages Sold Outside of the School Meals Programs About SHPPS: SHPPS is a national survey periodically conducted ... canteen, or snack bar where students could purchase foods or beverages. • 4.0% of states and 6.6% of ...

  15. Medicinal plants sold at traditional markets in southern Ecuador.

    Science.gov (United States)

    Tinitana, Fani; Rios, Montserrat; Romero-Benavides, Juan Carlos; de la Cruz Rot, Marcelino; Pardo-de-Santayana, Manuel

    2016-07-05

    The traditional markets in southern Ecuador and within the Andean region are especially important for plant resource trading among local people, even since before Spanish colonization; therefore, ethnobotanical studies are currently necessary and important. These strategic spaces persist for the traditional medicine cultural value reflected in the higher consumption of medicinal plants, which span all socioeconomic levels of rural and urban people. The purpose of this study includes the following: 1) to create a novel list of medicinal plants sold at 33 traditional markets; 2) to establish medicinal plant use agreement amongst vendors with the Factor of Informant Consensus (FIC); and 3) to determine the most sold medicinal plant species using the Fidelity Level (FL). This study focus on traditional markets ethnobotany utilizes the largest sample of medicinal plants market vendors up to date in Ecuador, interviewing them at 33 traditional markets, located within the Loja province. In order to determine the most sold medicinal plants and their ethnobotanical information, structured questionnaires and personal conversations were conducted with 196 medicinal plant vendors, and voucher specimens were created. Agreement among vendors about the therapeutic use of medicinal plants was measured using the FIC, and the most sold medicinal plant species were assessed with the FL. This research registered 160 medicinal plant species, grouped in 126 genera and 57 families that were sold in 33 traditional markets. The uses of medicinal plants in southern Ecuador are related to a long history of traditional medicine health practices that has persisted until today as well as high plant diversity. The 53 therapeutic uses recorded were grouped into 12 medical categories that were adapted from the World Health Organization. Three medical categories shared the highest value for FIC = 0.92, which showed a high level of agreement of market vendors for 57 medicinal plant species sold

  16. Construction of a frameless camera-based stereotactic neuronavigator.

    Science.gov (United States)

    Cornejo, A; Algorri, M E

    2004-01-01

    We built an infrared vision system to be used as the real time 3D motion sensor in a prototype low cost, high precision, frameless neuronavigator. The objective of the prototype is to develop accessible technology for increased availability of neuronavigation systems in research labs and small clinics and hospitals. We present our choice of technology including camera and IR emitter characteristics. We describe the methodology for setting up the 3D motion sensor, from the arrangement of the cameras and the IR emitters on surgical instruments, to triangulation equations from stereo camera pairs, high bandwidth computer communication with the cameras and real time image processing algorithms. We briefly cover the issues of camera calibration and characterization. Although our performance results do not yet fully meet the high precision, real time requirements of neuronavigation systems we describe the current improvements being made to the 3D motion sensor that will make it suitable for surgical applications.

  17. An investigation of the quality of meat sold in Lesotho

    Directory of Open Access Journals (Sweden)

    T.M. Seeiso

    2009-05-01

    Full Text Available Since the closure of the Lesotho abattoir in 2003, only imported meat can be legally sold. However, it was estimated in 2007 that 80 % of the meat sold at butcheries comes from informal slaughter. The aim of this study was to investigate the situation. The number and location of informal butcheries in Lesotho (n = 143 were recorded and mapped using Geographical Information Systems. Observations (photographs of informal slaughter indicated a lack of hygiene, unskilled slaughtermen and illegal disposal of offal with possible environmental pollution. In addition, a cross-sectional study was undertaken to determine the microbiological quality of meat from randomly selected carcasses (n = 237 of cattle, sheep and pigs from a sample of 44 butcheries, 4 of which were associated with registered supermarkets. As a control, samples for microbiological assay were taken from imported meat originating from carcasses (n = 20 slaughtered at a registered abattoir in South Africa. Of the 44 butcheries investigated only the 4 commercial butcheries associated with supermarkets sold imported meat only; 3 butcheries sold meat inspected at government slaughter slabs (n = 3, while the rest (n = 37 sold both imported and informally slaughtered meat. In terms of Lesotho legislation, informally slaughtered meat is only for home consumption. The bacteriological counts from all samples showed a total bacterial plate count exceeding 30 organisms per mℓ in contrast with the controls which all showed a count less than 5 colonies per mℓ. This was found for both imported and informally slaughtered meat sold in Lesotho. In addition, meat samples from butcheries showed the presence of the potential pathogens Salmonella (n = 2, Staphylococcus aureus (n = 12 and Escherichia coli (n=15. During the study, anthrax was confirmed in 9 human patients, 5 of whom died, after consumption of informally slaughtered livestock. Although no cases of animal abuse were detected, it was

  18. Coaxial fundus camera for opthalmology

    Science.gov (United States)

    de Matos, Luciana; Castro, Guilherme; Castro Neto, Jarbas C.

    2015-09-01

    A Fundus Camera for ophthalmology is a high definition device which needs to meet low light illumination of the human retina, high resolution in the retina and reflection free image1. Those constraints make its optical design very sophisticated, but the most difficult to comply with is the reflection free illumination and the final alignment due to the high number of non coaxial optical components in the system. Reflection of the illumination, both in the objective and at the cornea, mask image quality, and a poor alignment make the sophisticated optical design useless. In this work we developed a totally axial optical system for a non-midriatic Fundus Camera. The illumination is performed by a LED ring, coaxial with the optical system and composed of IR of visible LEDs. The illumination ring is projected by the objective lens in the cornea. The Objective, LED illuminator, CCD lens are coaxial making the final alignment easily to perform. The CCD + capture lens module is a CCTV camera with autofocus and Zoom built in, added to a 175 mm focal length doublet corrected for infinity, making the system easily operated and very compact.

  19. Making Ceramic Cameras

    Science.gov (United States)

    Squibb, Matt

    2009-01-01

    This article describes how to make a clay camera. This idea of creating functional cameras from clay allows students to experience ceramics, photography, and painting all in one unit. (Contains 1 resource and 3 online resources.)

  20. Development of Strained-Layer Superlattice (SLS) IR Detector Camera

    Data.gov (United States)

    National Aeronautics and Space Administration — Strained Layer Superlattice (SLS) detectors are a new class of detectors which may be the next generation of band-gap engineered, large format infrared detector...

  1. Adapting Virtual Camera Behaviour

    DEFF Research Database (Denmark)

    Burelli, Paolo

    2013-01-01

    In a three-dimensional virtual environment aspects such as narrative and interaction completely depend on the camera since the camera defines the player’s point of view. Most research works in automatic camera control aim to take the control of this aspect from the player to automatically gen- er...

  2. About possibility of temperature trace observing on a human skin through clothes by using computer processing of IR image

    Science.gov (United States)

    Trofimov, Vyacheslav A.; Trofimov, Vladislav V.; Shestakov, Ivan L.; Blednov, Roman G.

    2017-05-01

    One of urgent security problems is a detection of objects placed inside the human body. Obviously, for safety reasons one cannot use X-rays for such object detection widely and often. For this purpose, we propose to use THz camera and IR camera. Below we continue a possibility of IR camera using for a detection of temperature trace on a human body. In contrast to passive THz camera using, the IR camera does not allow to see very pronounced the object under clothing. Of course, this is a big disadvantage for a security problem solution based on the IR camera using. To find possible ways for this disadvantage overcoming we make some experiments with IR camera, produced by FLIR Company and develop novel approach for computer processing of images captured by IR camera. It allows us to increase a temperature resolution of IR camera as well as human year effective susceptibility enhancing. As a consequence of this, a possibility for seeing of a human body temperature changing through clothing appears. We analyze IR images of a person, which drinks water and eats chocolate. We follow a temperature trace on human body skin, caused by changing of temperature inside the human body. Some experiments are made with observing of temperature trace from objects placed behind think overall. Demonstrated results are very important for the detection of forbidden objects, concealed inside the human body, by using non-destructive control without using X-rays.

  3. 7 CFR 170.3 - What products may be sold at the USDA Farmers Market?

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false What products may be sold at the USDA Farmers Market...) MISCELLANEOUS MARKETING PRACTICES UNDER THE AGRICULTURAL MARKETING ACT OF 1946 USDA FARMERS MARKET § 170.3 What products may be sold at the USDA Farmers Market? Products that may be sold at the market include, but are...

  4. Multi-Angle Snowflake Camera Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Stuefer, Martin [Univ. of Alaska, Fairbanks, AK (United States); Bailey, J. [Univ. of Alaska, Fairbanks, AK (United States)

    2016-07-01

    The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASC cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.

  5. MOST SOLD CATEGORIES FOOD SUPPLEMENTS IN BULGARIAN PHARMACIES - RESEARCH

    OpenAIRE

    Elina Petkova1, Kalin Ivanov2, Stanislava Ivanova2*, Stanislav Gueorguiev3, Radiana Staynova3

    2017-01-01

    The aim of this study is to investigate which are the most sold categories food supplements in Bulgarian pharmacies. The survey covers 820 pharmacies across the country. We have found that the leading category of food supplements is “Immune and digestive health” (41.5%). The second place is for the “Bone and joint health” (12.9%). The “Urology” category (consisted mainly by plant extracts) is about 7.9%. Food supplements in the “Urology” category are not only recommended by pharmacists but of...

  6. Application of infrared camera to bituminous concrete pavements: measuring vehicle

    Science.gov (United States)

    Janků, Michal; Stryk, Josef

    2017-09-01

    Infrared thermography (IR) has been used for decades in certain fields. However, the technological level of advancement of measuring devices has not been sufficient for some applications. Over the recent years, good quality thermal cameras with high resolution and very high thermal sensitivity have started to appear on the market. The development in the field of measuring technologies allowed the use of infrared thermography in new fields and for larger number of users. This article describes the research in progress in Transport Research Centre with a focus on the use of infrared thermography for diagnostics of bituminous road pavements. A measuring vehicle, equipped with a thermal camera, digital camera and GPS sensor, was designed for the diagnostics of pavements. New, highly sensitive, thermal cameras allow to measure very small temperature differences from the moving vehicle. This study shows the potential of a high-speed inspection without lane closures while using IR thermography.

  7. Radiation camera exposure control

    International Nuclear Information System (INIS)

    Martone, R.J.; Yarsawich, M.; Wolczek, W.

    1976-01-01

    A system and method for governing the exposure of an image generated by a radiation camera to an image sensing camera is disclosed. The exposure is terminated in response to the accumulation of a predetermined quantity of radiation, defining a radiation density, occurring in a predetermined area. An index is produced which represents the value of that quantity of radiation whose accumulation causes the exposure termination. The value of the predetermined radiation quantity represented by the index is sensed so that the radiation camera image intensity can be calibrated to compensate for changes in exposure amounts due to desired variations in radiation density of the exposure, to maintain the detectability of the image by the image sensing camera notwithstanding such variations. Provision is also made for calibrating the image intensity in accordance with the sensitivity of the image sensing camera, and for locating the index for maintaining its detectability and causing the proper centering of the radiation camera image

  8. GRACE star camera noise

    Science.gov (United States)

    Harvey, Nate

    2016-08-01

    Extending results from previous work by Bandikova et al. (2012) and Inacio et al. (2015), this paper analyzes Gravity Recovery and Climate Experiment (GRACE) star camera attitude measurement noise by processing inter-camera quaternions from 2003 to 2015. We describe a correction to star camera data, which will eliminate a several-arcsec twice-per-rev error with daily modulation, currently visible in the auto-covariance function of the inter-camera quaternion, from future GRACE Level-1B product releases. We also present evidence supporting the argument that thermal conditions/settings affect long-term inter-camera attitude biases by at least tens-of-arcsecs, and that several-to-tens-of-arcsecs per-rev star camera errors depend largely on field-of-view.

  9. Solid state video cameras

    CERN Document Server

    Cristol, Y

    2013-01-01

    Solid State Video Cameras reviews the state of the art in the field of solid-state television cameras as compiled from patent literature. Organized into 10 chapters, the book begins with the basic array types of solid-state imagers and appropriate read-out circuits and methods. Documents relating to improvement of picture quality, such as spurious signal suppression, uniformity correction, or resolution enhancement, are also cited. The last part considerssolid-state color cameras.

  10. Characteristics of illegal and legal cigarette packs sold in Guatemala.

    Science.gov (United States)

    Arevalo, Rodrigo; Corral, Juan E; Monzon, Diego; Yoon, Mira; Barnoya, Joaquin

    2016-11-25

    Guatemala, as a party to the Framework Convention on Tobacco Control (FCTC), is required to regulate cigarette packaging and labeling and eliminate illicit tobacco trade. Current packaging and labeling characteristics (of legal and illegal cigarettes) and their compliance with the FCTC is unknown. We sought to analyze package and label characteristics of illegal and legal cigarettes sold in Guatemala. We visited the 22 largest traditional markets in the country to purchase illegal cigarettes. All brands registered on tobacco industry websites were purchased as legal cigarettes. Analysis compared labeling characteristics of illegal and legal packs. Most (95%) markets and street vendors sold illegal cigarettes; 104 packs were purchased (79 illegal and 25 legal). Ten percent of illegal and none of the legal packs had misleading terms. Half of the illegal packs had a warning label covering 26 to 50% of the pack surface. All legal packs had a label covering 25% of the surface. Illegal packs were more likely to have information on constituents and emissions (85% vs. 45%, p Guatemala, neither illegal nor legal cigarette packs comply with FCTC labeling mandates. Urgent implementation and enforcement of the FCTC is necessary to halt the tobacco epidemic.

  11. Thermal Cameras and Applications

    DEFF Research Database (Denmark)

    Gade, Rikke; Moeslund, Thomas B.

    2014-01-01

    Thermal cameras are passive sensors that capture the infrared radiation emitted by all objects with a temperature above absolute zero. This type of camera was originally developed as a surveillance and night vision tool for the military, but recently the price has dropped, significantly opening up...... a broader field of applications. Deploying this type of sensor in vision systems eliminates the illumination problems of normal greyscale and RGB cameras. This survey provides an overview of the current applications of thermal cameras. Applications include animals, agriculture, buildings, gas detection......, industrial, and military applications, as well as detection, tracking, and recognition of humans. Moreover, this survey describes the nature of thermal radiation and the technology of thermal cameras....

  12. Economic cost of electricity sold to new aluminium smelters

    International Nuclear Information System (INIS)

    Belanger, G.; Bernard, J.T.

    2008-01-01

    Low cost electricity was a key factor for establishing an aluminium industry in Quebec. Smelters in the province use 50 terawatt hours of electricity per year, which represents 25 per cent of the total consumed in Quebec. This article assessed the profitability of new industrial projects that require large quantities of electricity at a time when the cost of new power plants is increasing. However, electricity is being sold below cost and the difference is subsidized by the government. The investment is justified by the government because these new projects create high paying jobs. The authors presented cases of 2 new aluminium plants, and concluded that they represented a very high economic cost for the province. 1 tab

  13. Availability of Paracetamol Sold Over-the-Counter in Europe

    DEFF Research Database (Denmark)

    Morthorst, Britt Reuter; Erlangsen, Annette; Nordentoft, Merete

    2018-01-01

    Due to the risk of hepatotoxicity when excessive amounts of paracetamol are consumed, Poisons Information Centers (PICs) frequently receive paracetamol-related enquiries. This study examined how widely pack size restrictions of paracetamol sold over-the-counter have been implemented in Europe...... and also availability of paracetamol through non-pharmacy outlets and their possible associations with frequency of poisoning enquiries. A cross-sectional European multicentre questionnaire study was performed using a questionnaire to identify the extent and nature of paracetamol pack size restrictions......, non-pharmacy outlet sales and the frequency of paracetamol-related enquiries to PICs. In total, 21 European countries participated. All PICs provided telephone hotline services. In 14 (67%) countries, pack size restrictions had been implemented in pharmacies (range: 8-30 grams). No significant...

  14. Medicinal plants sold in the markets of Antananarivo, Madagascar.

    Science.gov (United States)

    Randriamiharisoa, Maria Nirina; Kuhlman, Alyse R; Jeannoda, Vololoniaina; Rabarison, Harison; Rakotoarivelo, Nivo; Randrianarivony, Tabita; Raktoarivony, Fortunat; Randrianasolo, Armand; Bussmann, Rainer W

    2015-07-28

    This study focuses on the large outdoor markets of the capital of Madagascar, Antananarivo. As the largest metropolitan area in Madagascar with a population of nearly two million, the region has great capacity for consumption of medicinal plant remedies despite numerous pharmacies. Medicinal plant use spans all socioeconomic levels, and the diverse metropolitan population allows us to study a wide variety of people who consume these plants for medical purposes. The purpose of this study is to identify and generate a list of medicinal plants sold in the traditional markets with a focus on those collected in the forests around Antananarivo, get an idea of the quantities of medicinal plants sold in the markets around Antananarivo, and assess the economy of the medicinal plant markets. In order to determine which medicinal plants are most consumed in Antananarivo, ethnobotanical enquiries were conducted in the five main markets of the capital city. Ethnobotanical surveys were conducted with medicinal plant traders, suppliers, harvesters and cultivators, with voucher specimens created from the plants discussed. Trade circuit information was established and the income generated by the trade of some of the species was assessed. The inventory of the Antananarivo markets resulted in a list of 89 commercialized plant species. Ten of the 89 were mentioned by 60-100 % of vendors. Profitability for vendors is high and competitive with other salaried positions within Antananarivo. Transportation costs are also high and therefore lower profitability for other members in the supply chain. The markets of Antananarivo have always played a vital cultural role in the lives of urban Malagasy, but our study shows they also play an economic role not only for urban residents but rural harvesters as well. Continued research and monitoring of the non-timber forest products trade in Antananarivo is needed to better understand the impact of trade on the wild plant populations.

  15. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  16. Thermal-to-visible transducer (TVT) for thermal-IR imaging

    Science.gov (United States)

    Flusberg, Allen; Swartz, Stephen; Huff, Michael; Gross, Steven

    2008-04-01

    We have been developing a novel thermal-to-visible transducer (TVT), an uncooled thermal-IR imager that is based on a Fabry-Perot Interferometer (FPI). The FPI-based IR imager can convert a thermal-IR image to a video electronic image. IR radiation that is emitted by an object in the scene is imaged onto an IR-absorbing material that is located within an FPI. Temperature variations generated by the spatial variations in the IR image intensity cause variations in optical thickness, modulating the reflectivity seen by a probe laser beam. The reflected probe is imaged onto a visible array, producing a visible image of the IR scene. This technology can provide low-cost IR cameras with excellent sensitivity, low power consumption, and the potential for self-registered fusion of thermal-IR and visible images. We will describe characteristics of requisite pixelated arrays that we have fabricated.

  17. Advanced CCD camera developments

    Energy Technology Data Exchange (ETDEWEB)

    Condor, A. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Two charge coupled device (CCD) camera systems are introduced and discussed, describing briefly the hardware involved, and the data obtained in their various applications. The Advanced Development Group Defense Sciences Engineering Division has been actively designing, manufacturing, fielding state-of-the-art CCD camera systems for over a decade. These systems were originally developed for the nuclear test program to record data from underground nuclear tests. Today, new and interesting application for these systems have surfaced and development is continuing in the area of advanced CCD camera systems, with the new CCD camera that will allow experimenters to replace film for x-ray imaging at the JANUS, USP, and NOVA laser facilities.

  18. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.; Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    A detailed description is given of a novel gamma camera which is designed to produce superior images than conventional cameras used in nuclear medicine. The detector consists of a solid state detector (e.g. germanium) which is formed to have a plurality of discrete components to enable 2-dimensional position identification. Details of the electronic processing circuits are given and the problems and limitations introduced by noise are discussed in full. (U.K.)

  19. Neutron cameras for ITER

    International Nuclear Information System (INIS)

    Johnson, L.C.; Barnes, C.W.; Batistoni, P.

    1998-01-01

    Neutron cameras with horizontal and vertical views have been designed for ITER, based on systems used on JET and TFTR. The cameras consist of fan-shaped arrays of collimated flight tubes, with suitably chosen detectors situated outside the biological shield. The sight lines view the ITER plasma through slots in the shield blanket and penetrate the vacuum vessel, cryostat, and biological shield through stainless steel windows. This paper analyzes the expected performance of several neutron camera arrangements for ITER. In addition to the reference designs, the authors examine proposed compact cameras, in which neutron fluxes are inferred from 16 N decay gammas in dedicated flowing water loops, and conventional cameras with fewer sight lines and more limited fields of view than in the reference designs. It is shown that the spatial sampling provided by the reference designs is sufficient to satisfy target measurement requirements and that some reduction in field of view may be permissible. The accuracy of measurements with 16 N-based compact cameras is not yet established, and they fail to satisfy requirements for parameter range and time resolution by large margins

  20. Strategic options towards an affordable high-performance infrared camera

    Science.gov (United States)

    Oduor, Patrick; Mizuno, Genki; Dutta, Achyut K.; Lewis, Jay; Dhar, Nibir K.

    2016-05-01

    The promise of infrared (IR) imaging attaining low-cost akin to CMOS sensors success has been hampered by the inability to achieve cost advantages that are necessary for crossover from military and industrial applications into the consumer and mass-scale commercial realm despite well documented advantages. Banpil Photonics is developing affordable IR cameras by adopting new strategies to speed-up the decline of the IR camera cost curve. We present a new short-wave IR (SWIR) camera; 640x512 pixel InGaAs uncooled system that is high sensitivity low noise ( 500 frames per second (FPS)) at full resolution, and low power consumption (market adoption by not only demonstrating high-performance IR imaging capability value add demanded by military and industrial application, but also illuminates a path towards justifiable price points essential for consumer facing application industries such as automotive, medical, and security imaging adoption. Among the strategic options presented include new sensor manufacturing technologies that scale favorably towards automation, multi-focal plane array compatible readout electronics, and dense or ultra-small pixel pitch devices.

  1. Divertor IR thermography on Alcator C-Moda)

    Science.gov (United States)

    Terry, J. L.; LaBombard, B.; Brunner, D.; Payne, J.; Wurden, G. A.

    2010-10-01

    Alcator C-Mod is a particularly challenging environment for thermography. It presents issues that will similarly face ITER, including low-emissivity metal targets, low-Z surface films, and closed divertor geometry. In order to make measurements of the incident divertor heat flux using IR thermography, the C-Mod divertor has been modified and instrumented. A 6° toroidal sector has been given a 2° toroidal ramp in order to eliminate magnetic field-line shadowing by imperfectly aligned divertor tiles. This sector is viewed from above by a toroidally displaced IR camera and is instrumented with thermocouples and calorimeters. The camera provides time histories of surface temperatures that are used to compute incident heat-flux profiles. The camera sensitivity is calibrated in situ using the embedded thermocouples, thus correcting for changes and nonuniformities in surface emissivity due to surface coatings.

  2. 5 CFR 6701.103 - Prohibited purchases of property sold by GSA.

    Science.gov (United States)

    2010-01-01

    ... paragraph (a) of this section does not apply to the purchase of foreign gifts deposited with the agency... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Prohibited purchases of property sold by... purchases of property sold by GSA. (a) General prohibition. Except as provided in paragraphs (b) and (c) of...

  3. Studies of IR-screening smoke clouds

    Energy Technology Data Exchange (ETDEWEB)

    Cudzilo, S. [Military Univ. of Technology, Warsaw (Poland)

    2001-02-01

    This paper contains some results of research on the IR-screening capability of smoke clouds generated during the combustion process of varied pyrotechnic formulations. The smoke compositions were made from some oxygen or oxygen-free mixtures containing metal and chloroorganic compounds or mixtures based on red phosphorus. The camouflage effectiveness of clouds generated by these formulations was investigated under laboratory conditions with an infrared camera. The technique employed enables determination of radiant temperature distributions in a smoke cloud treated as an energy equivalent of a grey body emission. The results of the analysis of thermographs from the camera were the basis on which the mixtures producing screens of the highest countermeasure for thermal imaging systems have been chosen. (orig.)

  4. Internal and External Factors Affecting The Size of Paddy Field Sold

    Directory of Open Access Journals (Sweden)

    Endang Rostiana

    2016-12-01

    Full Text Available This study attempted  to identify internal condition of the farmers who sold their paddy field and analyze the effects of age, education level, number of family members, field productivity, location, and production cost to the total area of paddy field sold. This study used quantitative descriptive method. This research found that age, education level, number of family members, and location of the land had positive relation to the total area of paddy field sold. On the other hand, production cost and field productivity had negative relation to the total area of paddy field sold. Partially, field production and number of family members had no significant effect to the total area of paddy field sold.

  5. Mislabelling of Döner kebab sold in Italy

    Directory of Open Access Journals (Sweden)

    Gaetano Liuzzo

    2016-11-01

    Full Text Available The aim of this study was to assess whether Döner kebabs sold in Italy comply with legal labelling requirements. A checklist of EU labelling requirements was drawn up and nine labels of Döner kebab marketed in the province of Modena were collected to evaluate the mandatory information laid down in article 9 of Regulation (EU No 1169/2011 together with the mandatory requirements of Regulation (EC 853/2004 for meat preparations. The study showed that different additives are commonly used in Döner kebabs, including E 621 (monosodium glutamate. This additive is not included among the ingredients authorized for the meat preparation food category. Eight frozen Döner kebab samples were taken and a visual assessment and a histologic examination were performed to verify potential changes in the meat’s inner muscle fibre structure that could allow the product to be considered among meat preparations or meat products. The Döner kebab labels showed several systematically deficient regulatory requirements in both extrinsic defects (not related to food composition and aspects concerning the protection of consumers’ health. Histological examination showed that the tissue was moderately swollen, but the muscle fibre structure was intact. Kebab can be reasonably classified as a meat preparation thereby precluding the use monosodium glutamate (E 621 as an ingredient.

  6. "Wow, It Turned out Red! First, a Little Yellow, and Then Red!" 1st-Graders' Work with an Infrared Camera

    Science.gov (United States)

    Jeppsson, Fredrik; Frejd, Johanna; Lundmark, Frida

    2017-01-01

    This study focuses on investigating how students make use of their bodily experiences in combination with infrared (IR) cameras, as a way to make meaning in learning about heat, temperature, and friction. A class of 20 primary students (age 7-8 years), divided into three groups, took part in three IR camera laboratory experiments. The qualitative…

  7. Commercialization of radiation tolerant camera

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Bum; Choi, Young Soo; Kim, Sun Ku; Lee, Jong Min; Cha, Bung Hun; Lee, Nam Ho; Byun, Eiy Gyo; Yoo, Seun Wook; Choi, Bum Ki; Yoon, Sung Up; Kim, Hyun Gun; Sin, Jeong Hun; So, Suk Il

    1999-12-01

    In this project, radiation tolerant camera which tolerates 10{sup 6} - 10{sup 8} rad total dose is developed. In order to develop radiation tolerant camera, radiation effect of camera components was examined and evaluated, and camera configuration was studied. By the result of evaluation, the components were decided and design was performed. Vidicon tube was selected to use by image sensor and non-browning optics and camera driving circuit were applied. The controller needed for CCTV camera system, lens, light, pan/tilt controller, was designed by the concept of remote control. And two type of radiation tolerant camera were fabricated consider to use in underwater environment or normal environment. (author)

  8. Commercialization of radiation tolerant camera

    International Nuclear Information System (INIS)

    Lee, Yong Bum; Choi, Young Soo; Kim, Sun Ku; Lee, Jong Min; Cha, Bung Hun; Lee, Nam Ho; Byun, Eiy Gyo; Yoo, Seun Wook; Choi, Bum Ki; Yoon, Sung Up; Kim, Hyun Gun; Sin, Jeong Hun; So, Suk Il

    1999-12-01

    In this project, radiation tolerant camera which tolerates 10 6 - 10 8 rad total dose is developed. In order to develop radiation tolerant camera, radiation effect of camera components was examined and evaluated, and camera configuration was studied. By the result of evaluation, the components were decided and design was performed. Vidicon tube was selected to use by image sensor and non-browning optics and camera driving circuit were applied. The controller needed for CCTV camera system, lens, light, pan/tilt controller, was designed by the concept of remote control. And two type of radiation tolerant camera were fabricated consider to use in underwater environment or normal environment. (author)

  9. Selective-imaging camera

    Science.gov (United States)

    Szu, Harold; Hsu, Charles; Landa, Joseph; Cha, Jae H.; Krapels, Keith A.

    2015-05-01

    How can we design cameras that image selectively in Full Electro-Magnetic (FEM) spectra? Without selective imaging, we cannot use, for example, ordinary tourist cameras to see through fire, smoke, or other obscurants contributing to creating a Visually Degraded Environment (VDE). This paper addresses a possible new design of selective-imaging cameras at firmware level. The design is consistent with physics of the irreversible thermodynamics of Boltzmann's molecular entropy. It enables imaging in appropriate FEM spectra for sensing through the VDE, and displaying in color spectra for Human Visual System (HVS). We sense within the spectra the largest entropy value of obscurants such as fire, smoke, etc. Then we apply a smart firmware implementation of Blind Sources Separation (BSS) to separate all entropy sources associated with specific Kelvin temperatures. Finally, we recompose the scene using specific RGB colors constrained by the HVS, by up/down shifting Planck spectra at each pixel and time.

  10. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each detector ring or offset ring includes a plurality of photomultiplier tubes and a plurality of scintillation crystals are positioned relative to the photomultiplier tubes whereby each tube is responsive to more than one crystal. Each alternate crystal in the ring is offset by one-half or less of the thickness of the crystal such that the staggered crystals are seen by more than one photomultiplier tube. This sharing of crystals and photomultiplier tubes allows identification of the staggered crystal and the use of smaller detectors shared by larger photomultiplier tubes thereby requiring less photomultiplier tubes, creating more scanning slices, providing better data sampling, and reducing the cost of the camera. The offset detector ring geometry reduces the costs of the positron camera and improves its performance

  11. The role of camera-bundled image management software in the consumer digital imaging value chain

    Science.gov (United States)

    Mueller, Milton; Mundkur, Anuradha; Balasubramanian, Ashok; Chirania, Virat

    2005-02-01

    This research was undertaken by the Convergence Center at the Syracuse University School of Information Studies (www.digital-convergence.info). Project ICONICA, the name for the research, focuses on the strategic implications of digital Images and the CONvergence of Image management and image CApture. Consumer imaging - the activity that we once called "photography" - is now recognized as in the throes of a digital transformation. At the end of 2003, market researchers estimated that about 30% of the households in the U.S. and 40% of the households in Japan owned digital cameras. In 2004, of the 86 million new cameras sold (excluding one-time use cameras), a majority (56%) were estimated to be digital cameras. Sales of photographic film, while still profitable, are declining precipitously.

  12. Radionuclide Content of Pasteurized Milk Sold in Mafikeng, South Africa

    International Nuclear Information System (INIS)

    Olobatoke, R.; Mathuthu, M.

    2015-01-01

    Many food animals which are important components of human food chain are effective collectors of radionuclides from the environment particularly contaminated forages, and therefore represent a significant pathway for the transfer of radionuclides to humans. Many important radionuclides are readily transferred to milk thus the product is considered as one of the basic food items recommended for the assessment of radionuclide exposure within a population. The current study aimed at assessing the radionuclide content of commercial milk commonly sold in South Africa in other to set a baseline data for radionuclide concentration of the products. Three popular brands of commercial milk (A, B and C) were sampled, with two samples obtained for each brand. The concentration of individual radionuclide in the milk samples, particularly "1"3"1I, "1"3"7Cs and "2"3"5U was measured by gamma spectroscopy. The results showed that brand A had the highest concentrations of "2"3"5U and "1"3"7Cs (203 and 324 mBq/l respectively) but the lowest concentration of "1"3"1I (6.4 mBq/l). The highest concentration of "1"3"1I (148 mBq/l) was detected in brand B whereas both "2"3"5U and "1"3"1I were not detected in brand C. All the values however were well below the new standard limits for individual radionuclides in milk established by the Japanese Ministry of Health, Labour and Welfare. This study indicates that the commercial milk brands assessed pose no radiation health threat to the consumers. (author)

  13. Cigarettes sold in China: design, emissions and metals.

    Science.gov (United States)

    O'Connor, Richard J; Li, Qiang; Stephens, W Edryd; Hammond, David; Elton-Marshall, Tara; Cummings, K Michael; Giovino, Gary A; Fong, Geoffrey T

    2010-10-01

    China is the home to the world's largest cigarette maker, China National Tobacco Company (CNTC), yet little is known publicly about the design and emissions of Chinese cigarettes. CNTC is currently in the process of consolidating its brands and has ambitions to export its cigarettes. Machine-measured tar yields of many of its cigarette brands have also been reduced, similar to what occurred in Western countries from the 1970s through the 1990s with so-called 'low-tar' cigarettes introduced to address consumer concerns about health risks from smoking. The current study examines the design and physical characteristics, labelled smoke emissions and tobacco metals content of leading brands of Chinese cigarettes from seven cities purchased in 2005-6 and in 2007. Findings suggest that similar to most countries, tar levels of Chinese cigarettes are predicted primarily by tobacco weight and filter ventilation. Ventilation explained approximately 50% of variation observed in tar and 60% variation in carbon monoxide yields. We found little significant change in key design features of cigarettes purchased in both rounds. We observed significant levels of various metals, averaging 0.82 μg/g arsenic (range 0.3-3.3), 3.21 μg/g cadmium (range 2.0-5.4) and 2.65 μg/g lead (range 1.2-6.5) in a subsample of 13 brands in 2005-6, substantially higher than contemporary Canadian products. Results suggest that cigarettes in China increasingly resemble those sold in Western countries, but with tobacco containing higher levels of heavy metals. As CNTC looks to export its product around the world, independent surveillance of tobacco product characteristics, including tobacco blend characteristics, will become increasingly important.

  14. Malaysian made condoms sold locally as well as exported.

    Science.gov (United States)

    1979-01-01

    Malaysia, famous for its natural rubber, is also producing condoms made from local rubber. About 40,000 gross of condoms a month are being produced by a factory with about 30 female workers. 30-40% of the production is exported to Europe, Middle East, Asia, Japan, Singapore and South America. The size of the condoms conform to international standards, 49 mm and 52 mm. As there is a greater demand for the 52 mm. condoms overseas, the company produces more of this than the 49 mm. condoms. In April 1975, the Standard Institution and Industrial Research of Malaysia gave its quality control approval to a condom which can hold 5 gallons of water and with thickness varying from 0.03 mm, 0.06 mm. and 0.05-0.07 mm. A 10% tax/piece and a 5% surtax are imposed on imported condoms to protect the local industry from foreign competition. Local condoms are sold tax-free. Pink and black colored condoms appear to be popular among consumers. Although complaints are few, 1 in 10,000 users may suffer from allergic problems because of the silicone oil treatment of the condoms. Another local condom factory which uses Malaysian rubber for condom manufacture is located in Klang, approximately 24 miles from Kuala Lumpur; the factory has 25 workers producing 12,000 gross of lubricated and non-lubricated condoms for local consumption only. There is increasing evidence that condoms are increasing in popularity in Malaysia and that the average consumer is now being more selective in choosing contraceptive methods.

  15. Automatic Camera Control

    DEFF Research Database (Denmark)

    Burelli, Paolo; Preuss, Mike

    2014-01-01

    Automatically generating computer animations is a challenging and complex problem with applications in games and film production. In this paper, we investigate howto translate a shot list for a virtual scene into a series of virtual camera configurations — i.e automatically controlling the virtual...

  16. The world's fastest camera

    CERN Multimedia

    Piquepaille, Roland

    2006-01-01

    This image processor is not your typical digital camera. It took 6 years to 20 people and $6 million to build the "Regional Calorimeter Trigger"(RCT) which will be a component of the Compact Muon Solenoid (CMS) experiment, one of the detectors on the Large Hadron Collider (LHC) in Geneva, Switzerland (1 page)

  17. Camera network video summarization

    Science.gov (United States)

    Panda, Rameswar; Roy-Chowdhury, Amit K.

    2017-05-01

    Networks of vision sensors are deployed in many settings, ranging from security needs to disaster response to environmental monitoring. Many of these setups have hundreds of cameras and tens of thousands of hours of video. The difficulty of analyzing such a massive volume of video data is apparent whenever there is an incident that requires foraging through vast video archives to identify events of interest. As a result, video summarization, that automatically extract a brief yet informative summary of these videos, has attracted intense attention in the recent years. Much progress has been made in developing a variety of ways to summarize a single video in form of a key sequence or video skim. However, generating a summary from a set of videos captured in a multi-camera network still remains as a novel and largely under-addressed problem. In this paper, with the aim of summarizing videos in a camera network, we introduce a novel representative selection approach via joint embedding and capped l21-norm minimization. The objective function is two-fold. The first is to capture the structural relationships of data points in a camera network via an embedding, which helps in characterizing the outliers and also in extracting a diverse set of representatives. The second is to use a capped l21-norm to model the sparsity and to suppress the influence of data outliers in representative selection. We propose to jointly optimize both of the objectives, such that embedding can not only characterize the structure, but also indicate the requirements of sparse representative selection. Extensive experiments on standard multi-camera datasets well demonstrate the efficacy of our method over state-of-the-art methods.

  18. Study on seasonal IR signature change of a ship by considering seasonal marine environmental conditions

    Science.gov (United States)

    Kim, Do-Hwi; Han, Kuk-Il; Choi, Jun-Hyuk; Kim, Tae-Kuk

    2017-05-01

    Infrared (IR) signal emitted from objects over 0 degree Kelvin has been used to detect and recognize the characteristics of those objects. Recently more delicate IR sensors have been applied for various guided missiles and they affect a crucial influence on object's survivability. Especially, in marine environment it is more vulnerable to be attacked by IR guided missiles since there are nearly no objects for concealment. To increase the survivability of object, the IR signal of the object needs to be analyzed properly by considering various marine environments. IR signature of a naval ship consists of the emitted energy from ship surface and the reflected energy by external sources. Surface property such as the emissivity and the absorptivity on the naval ship varies with different paints applied on the surface and the reflected IR signal is also affected by the surface radiative property, the sensor's geometric position and various climatic conditions in marine environment. Since the direct measurement of IR signal using IR camera is costly and time consuming job, computer simulation methods are developing rapidly to replace those experimental tasks. In this study, we are demonstrate a way of analyzing the IR signal characteristics by using the measured background IR signals using an IR camera and the estimated target IR signals from the computer simulation to find the seasonal trends of IR threats of a naval ship. Through this process, measured weather data are used to analyze more accurate IR signal conditions for the naval ship. The seasonal change of IR signal contrast between the naval ship and the marine background shows that the highest contrast radiant intensity (CRI) value is appeared in early summer.

  19. Dual cameras acquisition and display system of retina-like sensor camera and rectangular sensor camera

    Science.gov (United States)

    Cao, Nan; Cao, Fengmei; Lin, Yabin; Bai, Tingzhu; Song, Shengyu

    2015-04-01

    For a new kind of retina-like senor camera and a traditional rectangular sensor camera, dual cameras acquisition and display system need to be built. We introduce the principle and the development of retina-like senor. Image coordinates transformation and interpolation based on sub-pixel interpolation need to be realized for our retina-like sensor's special pixels distribution. The hardware platform is composed of retina-like senor camera, rectangular sensor camera, image grabber and PC. Combined the MIL and OpenCV library, the software program is composed in VC++ on VS 2010. Experience results show that the system can realizes two cameras' acquisition and display.

  20. Microbial quality of chevon and mutton sold in Tamale Metropolis of ...

    African Journals Online (AJOL)

    Michael Horsfall

    All rights reserved. J. Appl. Sci. ... Universiti Sains Malaysia, School of Industry Technology, 11800 Pulau Pinang, Malaysia. ABSTRACT: ... sold in the open market to consumers. Although ... microbiologically safe is increasing tremendously in.

  1. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each ring contains a plurality of scintillation detectors which are positioned around an inner circumference with a septum ring extending inwardly from the inner circumference along each outer edge of each ring. An additional septum ring is positioned in the middle of each ring of detectors and parallel to the other septa rings, whereby the inward extent of all the septa rings may be reduced by one-half and the number of detectors required in each ring is reduced. The additional septa reduces the costs of the positron camera and improves its performance

  2. Gamma ray camera

    International Nuclear Information System (INIS)

    Wang, S.-H.; Robbins, C.D.

    1979-01-01

    An Anger gamma ray camera is improved by the substitution of a gamma ray sensitive, proximity type image intensifier tube for the scintillator screen in the Anger camera. The image intensifier tube has a negatively charged flat scintillator screen, a flat photocathode layer, and a grounded, flat output phosphor display screen, all of which have the same dimension to maintain unit image magnification; all components are contained within a grounded metallic tube, with a metallic, inwardly curved input window between the scintillator screen and a collimator. The display screen can be viewed by an array of photomultipliers or solid state detectors. There are two photocathodes and two phosphor screens to give a two stage intensification, the two stages being optically coupled by a light guide. (author)

  3. NSTX Tangential Divertor Camera

    International Nuclear Information System (INIS)

    Roquemore, A.L.; Ted Biewer; Johnson, D.; Zweben, S.J.; Nobuhiro Nishino; Soukhanovskii, V.A.

    2004-01-01

    Strong magnetic field shear around the divertor x-point is numerically predicted to lead to strong spatial asymmetries in turbulence driven particle fluxes. To visualize the turbulence and associated impurity line emission near the lower x-point region, a new tangential observation port has been recently installed on NSTX. A reentrant sapphire window with a moveable in-vessel mirror images the divertor region from the center stack out to R 80 cm and views the x-point for most plasma configurations. A coherent fiber optic bundle transmits the image through a remotely selected filter to a fast camera, for example a 40500 frames/sec Photron CCD camera. A gas puffer located in the lower inboard divertor will localize the turbulence in the region near the x-point. Edge fluid and turbulent codes UEDGE and BOUT will be used to interpret impurity and deuterium emission fluctuation measurements in the divertor

  4. Scanning gamma camera

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Batter, J.F. Jr.; Stout, K.J.

    1977-01-01

    A scanning system for a gamma camera providing for the overlapping of adjacent scan paths is described. A collimator mask having tapered edges provides for a graduated reduction in intensity of radiation received by a detector thereof, the reduction in intensity being graduated in a direction normal to the scanning path to provide a blending of images of adjacent scan paths. 31 claims, 15 figures

  5. Gamma camera display system

    International Nuclear Information System (INIS)

    Stout, K.J.

    1976-01-01

    A gamma camera having an array of photomultipliers coupled via pulse shaping circuitry and a resistor weighting circuit to a display for forming an image of a radioactive subject is described. A linearizing circuit is coupled to the weighting circuit, the linearizing circuit including a nonlinear feedback circuit with diode coupling to the weighting circuit for linearizing the correspondence between points of the display and points of the subject. 4 Claims, 5 Drawing Figures

  6. Comparison of polarimetric cameras

    Science.gov (United States)

    2017-03-01

    Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302, and to the Office of Management and Budget , Paperwork Reduction Project (0704-0188...polarimetric camera, remote sensing, space systems 15. NUMBER OF PAGES 93 16. PRICE CODE 17. SECURITY CLASSIFICATION OF REPORT Unclassified 18...2016. Hermann Hall, Monterey, CA. The next data in Figure 37. were collected on 01 December 2016 at 1226 PST on the rooftop of the Marriot Hotel in

  7. Development of the Earth Observation Camera of MIRIS

    Directory of Open Access Journals (Sweden)

    Dae-Hee Lee

    2011-09-01

    Full Text Available We have designed and manufactured the Earth observation camera (EOC of multi-purpose infrared imaging system (MIRIS. MIRIS is a main payload of the STSAT-3, which will be launched in late 2012. The main objective of the EOC is to test the operation of Korean IR technology in space, so we have designed the optical and mechanical system of the EOC to fit the IR detector system. We have assembled the flight model (FM of EOC and performed environment tests successfully. The EOC is now ready to be integrated into the satellite system waiting for operation in space, as planned.

  8. Radiation-resistant camera tube

    International Nuclear Information System (INIS)

    Kuwahata, Takao; Manabe, Sohei; Makishima, Yasuhiro

    1982-01-01

    It was a long time ago that Toshiba launched on manufacturing black-and-white radiation-resistant camera tubes employing nonbrowning face-plate glass for ITV cameras used in nuclear power plants. Now in compliance with the increasing demand in nuclear power field, the Company is at grips with the development of radiation-resistant single color-camera tubes incorporating a color-stripe filter for color ITV cameras used under radiation environment. Herein represented are the results of experiments on characteristics of materials for single color-camera tubes and prospects for commercialization of the tubes. (author)

  9. Cloning and expression of SOLD1 in ovine and caprine placenta, and their expected roles during the development of placentomes

    Directory of Open Access Journals (Sweden)

    Kizaki Keiichiro

    2010-01-01

    Full Text Available Abstract Background The Ly-6 (Ly-6/uPAR superfamily members share the Ly-6 domain defined by distinct disulfide bonding patterns between 8 or 10 cysteine residues. They comprise membrane- and secretory-type proteins. We recently reported the gene and protein characterization of the bovine secreted protein of Ly-6 domain 1 (SOLD1. Bovine SOLD1 is expressed in trophoblast mononucleate cells (TMCs and is localized in the cotyledonary mesenchyme. Here, we compared the expression and functionality of SOLD1 among the ruminants. We examined mRNA expression by chorionic fibroblasts as a measure of one of the SOLD1 functions. Results Ovine and caprine SOLD1 mRNAs have 303 bp open reading frames and encode for deduced SOLD1 proteins with 100 amino acids, including a 22-aa-long signal peptide at the N-terminal. Both of the SOLD1 amino acid sequences have high similarities with the bovine sequence. Both SOLD1 mRNAs were also expressed in TMCs of cotyledons and intercotyledonary membranes. The mature SOLD1 proteins were localized in the mesenchymal villi of cotyledons after secretion. Bovine, ovine and caprine SOLD1 affected gene expression in mesenchymal fibroblasts in vitro; nucleoredoxin expression was upregulated and BCL2-like 13 was downregulated. Thus, we suggest that SOLD1 acts as a modulator of cell proliferation and apoptosis. Conclusion Expressing cells and protein localization of SOLD1 coincided among the three ruminants. SOLD1 participated in regulating nucleoredoxin and BCL2-like 13 expression in chorionic fibroblasts. SOLD1 is produced specifically in the cotyledons and intercotyledonary membranes in ruminants and appears to be involved in the construction of the ruminant placenta.

  10. Camera Movement in Narrative Cinema

    DEFF Research Database (Denmark)

    Nielsen, Jakob Isak

    2007-01-01

    section unearths what characterizes the literature on camera movement. The second section of the dissertation delineates the history of camera movement itself within narrative cinema. Several organizational principles subtending the on-screen effect of camera movement are revealed in section two...... but they are not organized into a coherent framework. This is the task that section three meets in proposing a functional taxonomy for camera movement in narrative cinema. Two presumptions subtend the taxonomy: That camera movement actively contributes to the way in which we understand the sound and images on the screen......, commentative or valuative manner. 4) Focalization: associating the movement of the camera with the viewpoints of characters or entities in the story world. 5) Reflexive: inviting spectators to engage with the artifice of camera movement. 6) Abstract: visualizing abstract ideas and concepts. In order...

  11. CCD camera eases the control of a soda recovery boiler; CCD-kamera helpottaa soodakattilan valvontaa

    Energy Technology Data Exchange (ETDEWEB)

    Kinnunen, L.

    2001-07-01

    Fortum Technology has developed a CCD firebox camera, based on semiconductor technology, enduring hard conditions of soda recovery boiler longer than traditional cameras. The firebox camera air- cooled and the same air is pressed over the main lens so it remains clean despite of the alkaline liquor splashing around in the boiler. The image of the boiler is transferred through the main lens, image transfer lens and a special filter, mounted inside the camera tube, into the CCD camera. The first CCD camera system has been in use since 1999 in Sunila pulp mill in Kotka, owned by Myllykoski Oy and Enso Oyj. The mill has two medium-sized soda recovery boilers. The amount of black liquor, formed daily, is about 2000 tons DS, which is more than enough for the heat generation. Even electric power generation exceeds sometimes the demand, so the surplus power can be sold out. Black liquor is sprayed inside the soda recovery boiler with high pressure. The liquor form droplets in the boiler, the temperature of which is over 1000 deg C. A full-hot pile is formed at the bottom of the boiler after burning. The size and shape of the pile effect on the efficiency and the emissions of the boiler. The camera has operated well.

  12. Automatic inference of geometric camera parameters and inter-camera topology in uncalibrated disjoint surveillance cameras

    Science.gov (United States)

    den Hollander, Richard J. M.; Bouma, Henri; Baan, Jan; Eendebak, Pieter T.; van Rest, Jeroen H. C.

    2015-10-01

    Person tracking across non-overlapping cameras and other types of video analytics benefit from spatial calibration information that allows an estimation of the distance between cameras and a relation between pixel coordinates and world coordinates within a camera. In a large environment with many cameras, or for frequent ad-hoc deployments of cameras, the cost of this calibration is high. This creates a barrier for the use of video analytics. Automating the calibration allows for a short configuration time, and the use of video analytics in a wider range of scenarios, including ad-hoc crisis situations and large scale surveillance systems. We show an autocalibration method entirely based on pedestrian detections in surveillance video in multiple non-overlapping cameras. In this paper, we show the two main components of automatic calibration. The first shows the intra-camera geometry estimation that leads to an estimate of the tilt angle, focal length and camera height, which is important for the conversion from pixels to meters and vice versa. The second component shows the inter-camera topology inference that leads to an estimate of the distance between cameras, which is important for spatio-temporal analysis of multi-camera tracking. This paper describes each of these methods and provides results on realistic video data.

  13. IR and the Earth

    DEFF Research Database (Denmark)

    Corry, Olaf; Stevenson, Hayley

    2017-01-01

    , in the end, one finite interconnected space. Together these two starting points make for the basic conundrum of Inter- national Relations and the Earth: how does a divided world live on a single globe? This introduction first provides an overview of the recent rise of ‘the environment’ in international......, ‘what has the environment ever done for IR?’, before the plan for the rest of the book sketches the content and direction of the ensuing chapters that explore the problematique of International Relations and the Earth....

  14. SCC500: next-generation infrared imaging camera core products with highly flexible architecture for unique camera designs

    Science.gov (United States)

    Rumbaugh, Roy N.; Grealish, Kevin; Kacir, Tom; Arsenault, Barry; Murphy, Robert H.; Miller, Scott

    2003-09-01

    A new 4th generation MicroIR architecture is introduced as the latest in the highly successful Standard Camera Core (SCC) series by BAE SYSTEMS to offer an infrared imaging engine with greatly reduced size, weight, power, and cost. The advanced SCC500 architecture provides great flexibility in configuration to include multiple resolutions, an industry standard Real Time Operating System (RTOS) for customer specific software application plug-ins, and a highly modular construction for unique physical and interface options. These microbolometer based camera cores offer outstanding and reliable performance over an extended operating temperature range to meet the demanding requirements of real-world environments. A highly integrated lens and shutter is included in the new SCC500 product enabling easy, drop-in camera designs for quick time-to-market product introductions.

  15. Video Chat with Multiple Cameras

    OpenAIRE

    MacCormick, John

    2012-01-01

    The dominant paradigm for video chat employs a single camera at each end of the conversation, but some conversations can be greatly enhanced by using multiple cameras at one or both ends. This paper provides the first rigorous investigation of multi-camera video chat, concentrating especially on the ability of users to switch between views at either end of the conversation. A user study of 23 individuals analyzes the advantages and disadvantages of permitting a user to switch between views at...

  16. Transmission electron microscope CCD camera

    Science.gov (United States)

    Downing, Kenneth H.

    1999-01-01

    In order to improve the performance of a CCD camera on a high voltage electron microscope, an electron decelerator is inserted between the microscope column and the CCD. This arrangement optimizes the interaction of the electron beam with the scintillator of the CCD camera while retaining optimization of the microscope optics and of the interaction of the beam with the specimen. Changing the electron beam energy between the specimen and camera allows both to be optimized.

  17. Detailed IR aperture measurements

    CERN Document Server

    Bruce, Roderik; Garcia Morales, Hector; Giovannozzi, Massimo; Hermes, Pascal Dominik; Mirarchi, Daniele; Quaranta, Elena; Redaelli, Stefano; Rossi, Carlo; Skowronski, Piotr Krzysztof; Wretborn, Sven Joel; CERN. Geneva. ATS Department

    2016-01-01

    MD 1673 was carried out on October 5 2016, in order to investigate in more detail the available aperture in the LHC high-luminosity insertions at 6.5 TeV and β∗=40 cm. Previous aperture measurements in 2016 during commissioning had shown that the available aperture is at the edge of protection, and that the aperture bottleneck at β∗=40 cm in certain cases is found in the separation plane instead of in the crossing plane. Furthermore, the bottlenecks were consistently found in close to the upstream end of Q3 on the side of the incoming beam, and not in Q2 on the outgoing beam as expected from calculations. Therefore, this MD aimed at measuring IR1 and IR5 separately (at 6.5 TeV and β∗=40 cm, for 185 µrad half crossing angle), to further localize the bottlenecks longitudinally using newly installed BLMs, investigate the difference in aperture between Q2 and Q3, and to see if any aperture can be gained using special orbit bumps.

  18. A Motionless Camera

    Science.gov (United States)

    1994-01-01

    Omniview, a motionless, noiseless, exceptionally versatile camera was developed for NASA as a receiving device for guiding space robots. The system can see in one direction and provide as many as four views simultaneously. Developed by Omniview, Inc. (formerly TRI) under a NASA Small Business Innovation Research (SBIR) grant, the system's image transformation electronics produce a real-time image from anywhere within a hemispherical field. Lens distortion is removed, and a corrected "flat" view appears on a monitor. Key elements are a high resolution charge coupled device (CCD), image correction circuitry and a microcomputer for image processing. The system can be adapted to existing installations. Applications include security and surveillance, teleconferencing, imaging, virtual reality, broadcast video and military operations. Omniview technology is now called IPIX. The company was founded in 1986 as TeleRobotics International, became Omniview in 1995, and changed its name to Interactive Pictures Corporation in 1997.

  19. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.

    1977-01-01

    A gamma camera system having control components operating in conjunction with a solid state detector is described. The detector is formed of a plurality of discrete components which are associated in geometrical or coordinate arrangement defining a detector matrix to derive coordinate signal outputs. These outputs are selectively filtered and summed to form coordinate channel signals and corresponding energy channel signals. A control feature of the invention regulates the noted summing and filtering performance to derive data acceptance signals which are addressed to further treating components. The latter components include coordinate and enery channel multiplexers as well as energy-responsive selective networks. A sequential control is provided for regulating the signal processing functions of the system to derive an overall imaging cycle

  20. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector planes positioned side-by-side around a patient area to detect radiation. Each plane includes a plurality of photomultiplier tubes and at least two rows of scintillation crystals on each photomultiplier tube extend across to adjacent photomultiplier tubes for detecting radiation from the patient area. Each row of crystals on each photomultiplier tube is offset from the other rows of crystals, and the area of each crystal on each tube in each row is different than the area of the crystals on the tube in other rows for detecting which crystal is actuated and allowing the detector to detect more inter-plane slides. The crystals are offset by an amount equal to the length of the crystal divided by the number of rows. The rows of crystals on opposite sides of the patient may be rotated 90 degrees relative to each other

  1. The Circular Camera Movement

    DEFF Research Database (Denmark)

    Hansen, Lennard Højbjerg

    2014-01-01

    It has been an accepted precept in film theory that specific stylistic features do not express specific content. Nevertheless, it is possible to find many examples in the history of film in which stylistic features do express specific content: for instance, the circular camera movement is used...... repeatedly to convey the feeling of a man and a woman falling in love. This raises the question of why producers and directors choose certain stylistic features to narrate certain categories of content. Through the analysis of several short film and TV clips, this article explores whether...... or not there are perceptual aspects related to specific stylistic features that enable them to be used for delimited narrational purposes. The article further attempts to reopen this particular stylistic debate by exploring the embodied aspects of visual perception in relation to specific stylistic features...

  2. Automatic locking radioisotope camera lock

    International Nuclear Information System (INIS)

    Rosauer, P.J.

    1978-01-01

    The lock of the present invention secures the isotope source in a stored shielded condition in the camera until a positive effort has been made to open the lock and take the source outside of the camera and prevents disconnection of the source pigtail unless the source is locked in a shielded condition in the camera. It also gives a visual indication of the locked or possible exposed condition of the isotope source and prevents the source pigtail from being completely pushed out of the camera, even when the lock is released. (author)

  3. Foods Sold in School Vending Machines are Associated with Overall Student Dietary Intake

    Science.gov (United States)

    Rovner, Alisha J.; Nansel, Tonja R.; Wang, Jing; Iannotti, Ronald J.

    2010-01-01

    Purpose To examine the association between foods sold in school vending machines and students’ dietary behaviors. Methods The 2005-2006 US Health Behavior in School Aged Children (HBSC) survey was administered to 6th to 10th graders and school administrators. Students’ dietary intake was estimated with a brief food frequency measure. Administrators completed questions about foods sold in vending machines. For each food intake behavior, a multilevel regression analysis modeled students (level 1) nested within schools (level 2), with the corresponding food sold in vending machines as the main predictor. Control variables included gender, grade, family affluence and school poverty. Analyses were conducted separately for 6th to 8th and 9th to 10th grades. Results Eighty-three percent of schools (152 schools, 5,930 students) had vending machines which primarily sold foods of minimal nutritional values (soft drinks, chips and sweets). In younger grades, availability of fruits/vegetables and chocolate/sweets was positively related to the corresponding food intake, with vending machine content and school poverty explaining 70.6% of between-school variation in fruit/vegetable consumption, and 71.7% in sweets consumption. In older grades, there was no significant effect of foods available in vending machines on reported consumption of those foods. Conclusions Vending machines are widely available in US public schools. In younger grades, school vending machines were related to students’ diets positively or negatively, depending on what was sold in them. Schools are in a powerful position to influence children’s diets; therefore attention to foods sold in them is necessary in order to try to improve children’s diets. PMID:21185519

  4. Food sold in school vending machines is associated with overall student dietary intake.

    Science.gov (United States)

    Rovner, Alisha J; Nansel, Tonja R; Wang, Jing; Iannotti, Ronald J

    2011-01-01

    To examine the association between food sold in school vending machines and the dietary behaviors of students. The 2005-2006 U.S. Health Behavior in School-aged Children survey was administered to 6th to 10th graders and school administrators. Dietary intake in students was estimated with a brief food frequency measure. School administrators completed questions regarding food sold in vending machines. For each food intake behavior, a multilevel regression analysis modeled students (level 1) nested within schools (level 2), with the corresponding food sold in vending machines as the main predictor. Control variables included gender, grade, family affluence, and school poverty index. Analyses were conducted separately for 6th to 8th and 9th-10th grades. In all, 83% of the schools (152 schools; 5,930 students) had vending machines that primarily sold food of minimal nutritional values (soft drinks, chips, and sweets). In younger grades, availability of fruit and/or vegetables and chocolate and/or sweets was positively related to the corresponding food intake, with vending machine content and school poverty index providing an explanation for 70.6% of between-school variation in fruit and/or vegetable consumption and 71.7% in sweets consumption. Among the older grades, there was no significant effect of food available in vending machines on reported consumption of those food. Vending machines are widely available in public schools in the United States. In younger grades, school vending machines were either positively or negatively related to the diets of the students, depending on what was sold in them. Schools are in a powerful position to influence the diets of children; therefore, attention to the food sold at school is necessary to try to improve their diets. Copyright © 2011 Society for Adolescent Health and Medicine. All rights reserved.

  5. The "All Sky Camera Network"

    Science.gov (United States)

    Caldwell, Andy

    2005-01-01

    In 2001, the "All Sky Camera Network" came to life as an outreach program to connect the Denver Museum of Nature and Science (DMNS) exhibit "Space Odyssey" with Colorado schools. The network is comprised of cameras placed strategically at schools throughout Colorado to capture fireballs--rare events that produce meteorites.…

  6. The Eye of the Camera

    NARCIS (Netherlands)

    van Rompay, Thomas Johannes Lucas; Vonk, Dorette J.; Fransen, M.L.

    2009-01-01

    This study addresses the effects of security cameras on prosocial behavior. Results from previous studies indicate that the presence of others can trigger helping behavior, arising from the need for approval of others. Extending these findings, the authors propose that security cameras can likewise

  7. The IRS-1 signaling system.

    Science.gov (United States)

    Myers, M G; Sun, X J; White, M F

    1994-07-01

    Insulin-receptor substrate 1 (IRS-1) is a principal substrate of the receptor tyrosine kinase for insulin and insulin-like growth factor 1, and a substrate for a tyrosine kinase activated by interleukin 4. IRS-1 undergoes multisite tyrosine phosphorylation and mediates downstream signals by 'docking' various proteins that contain Src homology 2 domains. IRS-1 appears to be a unique molecule; however, 4PS, a protein found mainly in hemopoietic cells, may represent another member of this family.

  8. Validation of the thermal code of RadTherm-IR, IR-Workbench, and F-TOM

    Science.gov (United States)

    Schwenger, Frédéric; Grossmann, Peter; Malaplate, Alain

    2009-05-01

    System assessment by image simulation requires synthetic scenarios that can be viewed by the device to be simulated. In addition to physical modeling of the camera, a reliable modeling of scene elements is necessary. Software products for modeling of target data in the IR should be capable of (i) predicting surface temperatures of scene elements over a long period of time and (ii) computing sensor views of the scenario. For such applications, FGAN-FOM acquired the software products RadTherm-IR (ThermoAnalytics Inc., Calumet, USA; IR-Workbench (OKTAL-SE, Toulouse, France). Inspection of the accuracy of simulation results by validation is necessary before using these products for applications. In the first step of validation, the performance of both "thermal solvers" was determined through comparison of the computed diurnal surface temperatures of a simple object with the corresponding values from measurements. CUBI is a rather simple geometric object with well known material parameters which makes it suitable for testing and validating object models in IR. It was used in this study as a test body. Comparison of calculated and measured surface temperature values will be presented, together with the results from the FGAN-FOM thermal object code F-TOM. In the second validation step, radiances of the simulated sensor views computed by RadTherm-IR and IR-Workbench will be compared with radiances retrieved from the recorded sensor images taken by the sensor that was simulated. Strengths and weaknesses of the models RadTherm-IR, IR-Workbench and F-TOM will be discussed.

  9. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.

    1982-01-01

    The invention provides a composite solid state detector for use in deriving a display, by spatial coordinate information, of the distribution or radiation emanating from a source within a region of interest, comprising several solid state detector components, each having a given surface arranged for exposure to impinging radiation and exhibiting discrete interactions therewith at given spatially definable locations. The surface of each component and the surface disposed opposite and substantially parallel thereto are associated with impedence means configured to provide for each opposed surface outputs for signals relating the given location of the interactions with one spatial coordinate parameter of one select directional sense. The detector components are arranged to provide groupings of adjacently disposed surfaces mutually linearly oriented to exhibit a common directional sense of the spatial coordinate parameter. Means interconnect at least two of the outputs associated with each of the surfaces within a given grouping for collecting the signals deriving therefrom. The invention also provides a camera system for imaging the distribution of a source of gamma radiation situated within a region of interest

  10. Microbial safety of raw mixed-vegetable salad sold as an ...

    African Journals Online (AJOL)

    A survey of 90 randomly selected subjects indicated raw mixed-vegetable salad as a popular accompaniment to cooked rice sold by street-food vendors in the Kokomlemle municipality of Accra, Ghana, but the salad was generally considered unwholesome and a potential cause of diarrhoea. A survey of 15 vendors of ...

  11. Microbiological Safety of Ready-to-eat Foods Sold in Primary ...

    African Journals Online (AJOL)

    A study was conducted to assess the microbial safety of ready-to-eat (RTE) foods sold in private and public primary schools in Abeokuta, South-western Nigeria. One hundred and sixty RTE food samples were collected from forty food vendors in thirty primary schools and analysed microbiologically. Socio-economic status ...

  12. Mycological Assessment of Suya Sold in Some Parts of Minna, Niger ...

    African Journals Online (AJOL)

    Mycological assessments of Suya sold in some part of Minna were conducted. A total of 20 samples were collected from 10 randomly selected suya spots from ten (10) locations in Minna namely- Tunga, Ungwan Daji , Dutsen Kuran Hausa, Chanchaga, Bosso, Maikunkele, Maitumbi, Kwangila, Barikin Sale and Sayeko.

  13. Microbiological and physicochemical characterization of shea butter sold on Benin markets

    NARCIS (Netherlands)

    Honfo, G.F.; Hell, K.; Akissoe, N.H.; Linnemann, A.R.; Coulibaly, O.

    2012-01-01

    Shea butter, a fat from the nuts of shea tree, is of great nutritional and commercial value for local communities of Africa. The sanitary and physicochemical qualities of shea butter sold in Benin markets are unknown. This study assesses the quality characteristics of 54 samples of shea butter

  14. Antioxidant potentials of local fruits and foreign wines sold in Ile-Ife ...

    African Journals Online (AJOL)

    Some locally consumed fruits, sugarcane and wines sold in Ile-Ife, Nigeria, were investigated for their phenol content and antioxidant potential of the methanolic extracts with a view of exploring the healthpromoting effect of the fruits and wines. The total phenolic content in each fruit and wines was determined ...

  15. Microbiological Quality Assessment of Ready-To-Eat Kilishi Sold in ...

    African Journals Online (AJOL)

    Microbiological Quality Assessment of Ready-To-Eat Kilishi Sold in Abuja, Nigeria. ... Animal Production Research Advances ... A total of twelve samples of ready-to-eat dried meat product, kilishi, were purchased from different sale-points in Abuja, Nigeria and a study conducted on them to assess their microbiological ...

  16. Microbial safety of raw mixed-vegetable salad sold as an ...

    African Journals Online (AJOL)

    Alex

    2012-06-21

    Jun 21, 2012 ... A recent popular street vended food is fried rice, which is a good imitation of that sold in Chinese restaurants, especially in the cities. Semi boiled rice is fried in oil with chopped vegetables, soy sauce and egg, and served with tomato ketchup and fried chicken. Kose is fried fritters of dehulled cowpea paste ...

  17. 40 CFR 152.30 - Pesticides that may be transferred, sold, or distributed without registration.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Pesticides that may be transferred... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PESTICIDE REGISTRATION AND CLASSIFICATION PROCEDURES Exemptions § 152.30 Pesticides that may be transferred, sold, or distributed without registration...

  18. Microbial analysis of meat and meat products sold in fast food ...

    African Journals Online (AJOL)

    The present study was carried out to investigate the rate of microbial contamination of ready-to-eat meat and meat products sold in different fast food restaurants in Aba. This study was carried out between June and August, 2015. Samples were collected aseptically from five fast food restaurants using sterile polythene bags.

  19. Antibiotic resistance profile of bacterial isolates from food sold on a ...

    African Journals Online (AJOL)

    The antibiotic resistance profile of bacterial isolates from cooked food samples sold in different eateries on the campus of the University of Ado-Ekiti was investigated. A total of seventy-eight bacterial isolates belonging to six genera were encountered in the following proportion: Escherichia coli (29.5%), Klebsiella spp.

  20. Marketing and utilization survey of some forest plant tubers sold in ...

    African Journals Online (AJOL)

    A marketing and utilization survey of some forest plants tubers sold in Abeokuta markets was conducted. Four markets were chosen namely, Itoku, Kuto, Adatan and Iberekodo with ,35, 25, 20, and 20 herb sellers respectively. Hundred percent enumerations of questionnaire were administered in the Markets. The number of ...

  1. 17 CFR 210.12-12A - Investments-securities sold short.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 2 2010-04-01 2010-04-01 false Investments-securities sold... EXCHANGE ACT OF 1934, PUBLIC UTILITY HOLDING COMPANY ACT OF 1935, INVESTMENT COMPANY ACT OF 1940, INVESTMENT ADVISERS ACT OF 1940, AND ENERGY POLICY AND CONSERVATION ACT OF 1975 Form and Content of Schedules...

  2. Development of underwater camera using high-definition camera

    International Nuclear Information System (INIS)

    Tsuji, Kenji; Watanabe, Masato; Takashima, Masanobu; Kawamura, Shingo; Tanaka, Hiroyuki

    2012-01-01

    In order to reduce the time for core verification or visual inspection of BWR fuels, the underwater camera using a High-Definition camera has been developed. As a result of this development, the underwater camera has 2 lights and 370 x 400 x 328mm dimensions and 20.5kg weight. Using the camera, 6 or so spent-fuel IDs are identified at 1 or 1.5m distance at a time, and 0.3mmφ pin-hole is recognized at 1.5m distance and 20 times zoom-up. Noises caused by radiation less than 15 Gy/h are not affected the images. (author)

  3. Polarizing aperture stereoscopic cinema camera

    Science.gov (United States)

    Lipton, Lenny

    2012-07-01

    The art of stereoscopic cinematography has been held back because of the lack of a convenient way to reduce the stereo camera lenses' interaxial to less than the distance between the eyes. This article describes a unified stereoscopic camera and lens design that allows for varying the interaxial separation to small values using a unique electro-optical polarizing aperture design for imaging left and right perspective views onto a large single digital sensor, the size of the standard 35 mm frame, with the means to select left and right image information. Even with the added stereoscopic capability, the appearance of existing camera bodies will be unaltered.

  4. Control system for gamma camera

    International Nuclear Information System (INIS)

    Miller, D.W.

    1977-01-01

    An improved gamma camera arrangement is described which utilizing a solid state detector, formed of high purity germanium. the central arrangement of the camera operates to effect the carrying out of a trapezoidal filtering operation over antisymmetrically summed spatial signals through gated integration procedures utilizing idealized integrating intervals. By simultaneously carrying out peak energy evaluation of the input signals, a desirable control over pulse pile-up phenomena is achieved. Additionally, through the use of the time derivative of incoming pulse or signal energy information to initially enable the control system, a low level information evaluation is provided serving to enhance the signal processing efficiency of the camera

  5. STREAK CAMERA MEASUREMENTS OF THE APS PC GUN DRIVE LASER

    Energy Technology Data Exchange (ETDEWEB)

    Dooling, J. C.; Lumpkin, A. H.

    2017-06-25

    We report recent pulse-duration measurements of the APS PC Gun drive laser at both second harmonic and fourth harmonic wavelengths. The drive laser is a Nd:Glass-based chirped pulsed amplifier (CPA) operating at an IR wavelength of 1053 nm, twice frequency-doubled to obtain UV output for the gun. A Hamamatsu C5680 streak camera and an M5675 synchroscan unit are used for these measurements; the synchroscan unit is tuned to 119 MHz, the 24th subharmonic of the linac s-band operating frequency. Calibration is accomplished both electronically and optically. Electronic calibration utilizes a programmable delay line in the 119 MHz rf path. The optical delay uses an etalon with known spacing between reflecting surfaces and is coated for the visible, SH wavelength. IR pulse duration is monitored with an autocorrelator. Fitting the streak camera image projected profiles with Gaussians, UV rms pulse durations are found to vary from 2.1 ps to 3.5 ps as the IR varies from 2.2 ps to 5.2 ps.

  6. Design, Manufacturing, and Commissioning of BIRCAM (Bootes InfraRed CAMera

    Directory of Open Access Journals (Sweden)

    Alberto Riva

    2010-01-01

    Full Text Available This paper covers the various aspect of design, manufacturing and commissioning of the infrared camera BIRCAM, installed at BOOTES-IR, the 60 cm robotic infrared telescope at Sierra Nevada Observatory (OSN, Granada, Spain. We describe how we achieved a quality astronomical image, moving from the scientific requirements.

  7. University Physics Students' Ideas of Thermal Radiation Expressed in Open Laboratory Activities Using Infrared Cameras

    Science.gov (United States)

    Haglund, Jesper; Melander, Emil; Weiszflog, Matthias; Andersson, Staffan

    2017-01-01

    Background: University physics students were engaged in open-ended thermodynamics laboratory activities with a focus on understanding a chosen phenomenon or the principle of laboratory apparatus, such as thermal radiation and a heat pump. Students had access to handheld infrared (IR) cameras for their investigations. Purpose: The purpose of the…

  8. Analyzer for gamma cameras diagnostic

    International Nuclear Information System (INIS)

    Oramas Polo, I.; Osorio Deliz, J. F.; Diaz Garcia, A.

    2013-01-01

    This research work was carried out to develop an analyzer for gamma cameras diagnostic. It is composed of an electronic system that includes hardware and software capabilities, and operates from the acquisition of the 4 head position signals of a gamma camera detector. The result is the spectrum of the energy delivered by nuclear radiation coming from the camera detector head. This system includes analog processing of position signals from the camera, digitization and the subsequent processing of the energy signal in a multichannel analyzer, sending data to a computer via a standard USB port and processing of data in a personal computer to obtain the final histogram. The circuits are composed of an analog processing board and a universal kit with micro controller and programmable gate array. (Author)

  9. Non-Linear Optical Studies of IR Materials with Infrared Femtosecond Laser

    Science.gov (United States)

    2016-12-15

    chemical/bio weapon signatures in real time. • IR sources and detectors have a wide ranging applications in public sector from night vision cameras on cars...Jeffrey D. Bude, Andy J. Bayramian, Christopher D. Marshall, Thomas M. Spinka, Constantin L. Haefner, Test station development for laser-induced

  10. Astronomy and the camera obscura

    Science.gov (United States)

    Feist, M.

    2000-02-01

    The camera obscura (from Latin meaning darkened chamber) is a simple optical device with a long history. In the form considered here, it can be traced back to 1550. It had its heyday during the Victorian era when it was to be found at the seaside as a tourist attraction or sideshow. It was also used as an artist's drawing aid and, in 1620, the famous astronomer-mathematician, Johannes Kepler used a small tent camera obscura to trace the scenery.

  11. The future of consumer cameras

    Science.gov (United States)

    Battiato, Sebastiano; Moltisanti, Marco

    2015-03-01

    In the last two decades multimedia, and in particular imaging devices (camcorders, tablets, mobile phones, etc.) have been dramatically diffused. Moreover the increasing of their computational performances, combined with an higher storage capability, allows them to process large amount of data. In this paper an overview of the current trends of consumer cameras market and technology will be given, providing also some details about the recent past (from Digital Still Camera up today) and forthcoming key issues.

  12. Science, conservation, and camera traps

    Science.gov (United States)

    Nichols, James D.; Karanth, K. Ullas; O'Connel, Allan F.; O'Connell, Allan F.; Nichols, James D.; Karanth, K. Ullas

    2011-01-01

    Biologists commonly perceive camera traps as a new tool that enables them to enter the hitherto secret world of wild animals. Camera traps are being used in a wide range of studies dealing with animal ecology, behavior, and conservation. Our intention in this volume is not to simply present the various uses of camera traps, but to focus on their use in the conduct of science and conservation. In this chapter, we provide an overview of these two broad classes of endeavor and sketch the manner in which camera traps are likely to be able to contribute to them. Our main point here is that neither photographs of individual animals, nor detection history data, nor parameter estimates generated from detection histories are the ultimate objective of a camera trap study directed at either science or management. Instead, the ultimate objectives are best viewed as either gaining an understanding of how ecological systems work (science) or trying to make wise decisions that move systems from less desirable to more desirable states (conservation, management). Therefore, we briefly describe here basic approaches to science and management, emphasizing the role of field data and associated analyses in these processes. We provide examples of ways in which camera trap data can inform science and management.

  13. Computing camera heading: A study

    Science.gov (United States)

    Zhang, John Jiaxiang

    2000-08-01

    An accurate estimate of the motion of a camera is a crucial first step for the 3D reconstruction of sites, objects, and buildings from video. Solutions to the camera heading problem can be readily applied to many areas, such as robotic navigation, surgical operation, video special effects, multimedia, and lately even in internet commerce. From image sequences of a real world scene, the problem is to calculate the directions of the camera translations. The presence of rotations makes this problem very hard. This is because rotations and translations can have similar effects on the images, and are thus hard to tell apart. However, the visual angles between the projection rays of point pairs are unaffected by rotations, and their changes over time contain sufficient information to determine the direction of camera translation. We developed a new formulation of the visual angle disparity approach, first introduced by Tomasi, to the camera heading problem. Our new derivation makes theoretical analysis possible. Most notably, a theorem is obtained that locates all possible singularities of the residual function for the underlying optimization problem. This allows identifying all computation trouble spots beforehand, and to design reliable and accurate computational optimization methods. A bootstrap-jackknife resampling method simultaneously reduces complexity and tolerates outliers well. Experiments with image sequences show accurate results when compared with the true camera motion as measured with mechanical devices.

  14. Mass and energy-capital conservation equations to study the price evolution of non-renewable energy resources. Part II-Extension to resources sold to the market

    International Nuclear Information System (INIS)

    Gori, F.

    2006-01-01

    The time evolution of the price of resources sold to the market and of the price difference, between sold and extracted resources, is investigated in case of no accumulation of the resources; i.e. when the resources are extracted and sold to the market at the same mass flow rate. The price evolution of sold resources varies with time according to the relation between the price increase factor, PIF, of sold and extracted resources. The price evolutions of sold resources and price difference are investigated according to the relation between extraction rate and interest rate of extracted and sold resources. The price of sold resources and the price difference increase with time if the PIF of sold resources is greater than the PIF of extracted resources and the initial price is greater than the critical price of sold resources, which depends on the initial price of extracted resources and the interest rate of non-extracted and extracted resources. The price of sold resources and the price difference decrease with time if the PIF of sold resources is greater than the PIF of extracted resources and the initial price is smaller than the critical price of sold resources. The other cases are discussed extensively in the paper. (author)

  15. A high resolution IR/visible imaging system for the W7-X limiter

    International Nuclear Information System (INIS)

    Wurden, G. A.; Dunn, J. P.; Stephey, L. A.; Biedermann, C.; Jakubowski, M. W.; Gamradt, M.

    2016-01-01

    A high-resolution imaging system, consisting of megapixel mid-IR and visible cameras along the same line of sight, has been prepared for the new W7-X stellarator and was operated during Operational Period 1.1 to view one of the five inboard graphite limiters. The radial line of sight, through a large diameter (184 mm clear aperture) uncoated sapphire window, couples a direct viewing 1344 × 784 pixel FLIR SC8303HD camera. A germanium beam-splitter sends visible light to a 1024 × 1024 pixel Allied Vision Technologies Prosilica GX1050 color camera. Both achieve sub-millimeter resolution on the 161 mm wide, inertially cooled, segmented graphite tiles. The IR and visible cameras are controlled via optical fibers over full Camera Link and dual GigE Ethernet (2 Gbit/s data rates) interfaces, respectively. While they are mounted outside the cryostat at a distance of 3.2 m from the limiter, they are close to a large magnetic trim coil and require soft iron shielding. We have taken IR data at 125 Hz to 1.25 kHz frame rates and seen that surface temperature increases in excess of 350 °C, especially on leading edges or defect hot spots. The IR camera sees heat-load stripe patterns on the limiter and has been used to infer limiter power fluxes (∼1–4.5 MW/m"2), during the ECRH heating phase. IR images have also been used calorimetrically between shots to measure equilibrated bulk tile temperature, and hence tile energy inputs (in the range of 30 kJ/tile with 0.6 MW, 6 s heating pulses). Small UFO’s can be seen and tracked by the FLIR camera in some discharges. The calibrated visible color camera (100 Hz frame rate) has also been equipped with narrow band C-III and H-alpha filters, to compare with other diagnostics, and is used for absolute particle flux determination from the limiter surface. Sometimes, but not always, hot-spots in the IR are also seen to be bright in C-III light.

  16. A high resolution IR/visible imaging system for the W7-X limiter

    Energy Technology Data Exchange (ETDEWEB)

    Wurden, G. A., E-mail: wurden@lanl.gov; Dunn, J. P. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Stephey, L. A. [University of Wisconsin, Madison, Wisconsin 53706 (United States); Biedermann, C.; Jakubowski, M. W.; Gamradt, M. [Max Planck Institut für Plasma Physik, Wendelsteinstrasse 1, 17491 Greifswald (Germany)

    2016-11-15

    A high-resolution imaging system, consisting of megapixel mid-IR and visible cameras along the same line of sight, has been prepared for the new W7-X stellarator and was operated during Operational Period 1.1 to view one of the five inboard graphite limiters. The radial line of sight, through a large diameter (184 mm clear aperture) uncoated sapphire window, couples a direct viewing 1344 × 784 pixel FLIR SC8303HD camera. A germanium beam-splitter sends visible light to a 1024 × 1024 pixel Allied Vision Technologies Prosilica GX1050 color camera. Both achieve sub-millimeter resolution on the 161 mm wide, inertially cooled, segmented graphite tiles. The IR and visible cameras are controlled via optical fibers over full Camera Link and dual GigE Ethernet (2 Gbit/s data rates) interfaces, respectively. While they are mounted outside the cryostat at a distance of 3.2 m from the limiter, they are close to a large magnetic trim coil and require soft iron shielding. We have taken IR data at 125 Hz to 1.25 kHz frame rates and seen that surface temperature increases in excess of 350 °C, especially on leading edges or defect hot spots. The IR camera sees heat-load stripe patterns on the limiter and has been used to infer limiter power fluxes (∼1–4.5 MW/m{sup 2}), during the ECRH heating phase. IR images have also been used calorimetrically between shots to measure equilibrated bulk tile temperature, and hence tile energy inputs (in the range of 30 kJ/tile with 0.6 MW, 6 s heating pulses). Small UFO’s can be seen and tracked by the FLIR camera in some discharges. The calibrated visible color camera (100 Hz frame rate) has also been equipped with narrow band C-III and H-alpha filters, to compare with other diagnostics, and is used for absolute particle flux determination from the limiter surface. Sometimes, but not always, hot-spots in the IR are also seen to be bright in C-III light.

  17. Regulatory considerations and quality assurance of depleted uranium based radiography cameras

    International Nuclear Information System (INIS)

    Sapkal, Jyotsna A.; Yadav, R.K.B.; Amrota, C.T.; Singh, Pratap; GopaIakrishanan, R.H.; Patil, B.N.; Mane, Nilesh

    2016-01-01

    Radiography cameras with shielding material as Depleted Uranium (DU) are used for containment of Iridium ( 192 Ir) source. DU shielding surrounds the titanium made 'S' tube through which the encapsulated 192 Ir source along with the pigtail travels. As per guidelines, it is required to check periodically the shielding integrity of DU shielding periodically by monitoring for alpha transferable contamination inside the 'S' tube. This paper describes in brief the method followed for collection of samples from inside the 'S' tube . The samples were analysed for transferable contamination due to gross alpha using alpha scintillation (ALSCIN) counter. The gross alpha contamination in the 'S' tube was found to be less than the recommended USNRC value for discarding the radiography camera. IAEA recommendations related to transferable contamination and AERB guidelines on the quality assurance (QA) requirements of radiography camera were studied

  18. Looking at Art in the IR and UV

    Science.gov (United States)

    Falco, Charles

    2013-03-01

    Starting with the very earliest cave paintings art has been created to be viewed by the unaided eye and, until very recently, it wasn't even possible to see it at wavelengths outside the visible spectrum. However, it is now possible to view paintings, sculptures, manuscripts, and other cultural artifacts at wavelengths from the x-ray, through the ultraviolet (UV), to well into the infrared (IR). Further, thanks to recent advances in technology, this is becoming possible with hand-held instruments that can be used in locations that were previously inaccessible to anything but laboratory-scale image capture equipment. But, what can be learned from such ``non-visible'' images? In this talk I will briefly describe the characteristics of high resolution UV and IR imaging systems I developed for this purpose by modifying high resolution digital cameras. The sensitivity of the IR camera makes it possible to obtain images of art ``in situ'' with standard museum lighting, resolving features finer than 0.35 mm on a 1.0x0.67 m painting. I also have used both it and the UV camera in remote locations with battery-powered illumination sources. I will illustrate their capabilities with images of various examples of Western, Asian, and Islamic art in museums on three continents, describing how these images have revealed important new information about the working practices of artists as famous as Jan van Eyck. I also will describe what will be possible for this type of work with new capabilities that could be developed within the next few years. This work is based on a collaboration with David Hockney, and benefitted from image analys research supported by ARO grant W911NF-06-1-0359-P00001.

  19. Parasitic contamination of fresh vegetables sold at central markets in Khartoum state, Sudan

    OpenAIRE

    Mohamed, Mona Ali; Siddig, Emmanuel Edwar; Elaagip, Arwa Hassan; Edris, Ali Mahmoud Mohammed; Nasr, Awad Ahmed

    2016-01-01

    Background Fresh vegetables are considered as vital nutrients of a healthy diet as they supply the body with essential supplements. The consumption of raw vegetables is the main way for transmission of intestinal parasitic organisms. This study was aimed at detecting the parasitic contamination in fresh vegetables sold in two central open-aired markets in Khartoum state, Sudan. Methods In this prospective cross-sectional study, a total of 260 fresh vegetable samples and 50 water samples used ...

  20. Isolation of pathogenic Escherichia coli from buffalo meat sold in Parbhani city, Maharashtra, India

    OpenAIRE

    M. S. Vaidya; N. M. Markandeya; R. N. Waghamare; C. S. Shekh; V. V. Deshmukh

    2013-01-01

    Aim: Isolation, characterization, in-vitro pathogenicity and antibiogram study of E.coli from buffalo meat sold in Parbhani city. Materials and Methods: Meat samples were collected from buffalo immediately after slaughter. Isolation, identification and enumeration of E. coli were done by following standard methods and protocols. Hemolysin test and Congo red binding assay were used to study in-vitro pathogenicity of E. coli isolates. Disc diffusion method was used to study antibiogram of patho...

  1. Wild vegetable mixes sold in the markets of Dalmatia (southern Croatia).

    Science.gov (United States)

    Łuczaj, Łukasz; Zovkokončić, Marijana; Miličević, Tihomir; Dolina, Katija; Pandža, Marija

    2013-01-03

    Dalmatia is an interesting place to study the use of wild greens as it lies at the intersection of influence of Slavs, who do not usually use many species of wild greens, and Mediterranean culinary culture, where the use of multiple wild greens is common. The aim of the study was to document the mixtures of wild green vegetables which are sold in all the vegetable markets of Dalmatia. All vendors (68) in all 11 major markets of the Dalmatian coast were interviewed. The piles of wild vegetables they sold were searched and herbarium specimens taken from them. The mean number of species in the mix was 5.7. The most commonly sold wild plants are: Sonchus oleraceus L., Allium ampeloprasum L., Foeniculum vulgare Mill., Urospermum picroides F.W.Schmidt, Papaver rhoeas L., Daucus carota L., Taraxacum sp., Picris echioides L., Silene latifolia Poir. and Crepis spp. Also the cultivated beet (Beta vulgaris L.) and a few cultivated Brassicaceae varieties are frequent components. Wild vegetables from the mix are usually boiled for 20-30 minutes and dressed with olive oil and salt. Altogether at least 37 wild taxa and 13 cultivated taxa were recorded.Apart from the mixes, Asparagus acutifolius L. and Tamus communis L. shoots are sold in separate bunches (they are usually eaten with eggs), as well as some Asteraceae species, the latter are eaten raw or briefly boiled. The rich tradition of eating many wild greens may result both from strong Venetian and Greek influences and the necessity of using all food resources available in the barren, infertile land in the past. Although the number of wild-collected green vegetables is impressive we hypothesize that it may have decreased over the years, and that further in-depth local ethnobotanical studies are needed in Dalmatia to record the disappearing knowledge of edible plants.

  2. Wild vegetable mixes sold in the markets of Dalmatia (southern Croatia

    Directory of Open Access Journals (Sweden)

    Łuczaj Łukasz

    2013-01-01

    Full Text Available Abstract Background Dalmatia is an interesting place to study the use of wild greens as it lies at the intersection of influence of Slavs, who do not usually use many species of wild greens, and Mediterranean culinary culture, where the use of multiple wild greens is common. The aim of the study was to document the mixtures of wild green vegetables which are sold in all the vegetable markets of Dalmatia. Methods All vendors (68 in all 11 major markets of the Dalmatian coast were interviewed. The piles of wild vegetables they sold were searched and herbarium specimens taken from them. Results The mean number of species in the mix was 5.7. The most commonly sold wild plants are: Sonchus oleraceus L., Allium ampeloprasum L., Foeniculum vulgare Mill., Urospermum picroides F.W.Schmidt, Papaver rhoeas L., Daucus carota L., Taraxacum sp., Picris echioides L., Silene latifolia Poir. and Crepis spp. Also the cultivated beet (Beta vulgaris L. and a few cultivated Brassicaceae varieties are frequent components. Wild vegetables from the mix are usually boiled for 20–30 minutes and dressed with olive oil and salt. Altogether at least 37 wild taxa and 13 cultivated taxa were recorded. Apart from the mixes, Asparagus acutifolius L. and Tamus communis L. shoots are sold in separate bunches (they are usually eaten with eggs, as well as some Asteraceae species, the latter are eaten raw or briefly boiled. Conclusions The rich tradition of eating many wild greens may result both from strong Venetian and Greek influences and the necessity of using all food resources available in the barren, infertile land in the past. Although the number of wild-collected green vegetables is impressive we hypothesize that it may have decreased over the years, and that further in-depth local ethnobotanical studies are needed in Dalmatia to record the disappearing knowledge of edible plants.

  3. The Trading Balance Sheet Of Romania - Two Decades With An Annual Adverse Sold

    Directory of Open Access Journals (Sweden)

    Simona Corina GUDEI

    2011-03-01

    Full Text Available The current communication, expressing the entirely special importance that must be granted to the fact that for two decades, year after year, the sold of the trading balance sheet of Romania was adverse. Moreover, it has increased greatly during the decade 2000-2009 towards the previous decade 1990-1999, respectively from 20 milliards dollars to 100 milliards of dollars, with especially serious consequences both on the external and on the internal economic balance.

  4. Palytoxin Found in Palythoa sp. Zoanthids (Anthozoa, Hexacorallia) Sold in the Home Aquarium Trade

    OpenAIRE

    Deeds, Jonathan R.; Handy, Sara M.; White, Kevin D.; Reimer, James D.

    2011-01-01

    Zoanthids (Anthozoa, Hexacorallia) are colonial anemones that contain one of the deadliest toxins ever discovered, palytoxin (LD(50) in mice 300 ng/kg), but it is generally believed that highly toxic species are not sold in the home aquarium trade. We previously showed that an unintentionally introduced zoanthid in a home aquarium contained high concentrations of palytoxin and was likely responsible for a severe respiratory reaction when an individual attempted to eliminate the contaminant co...

  5. Sub-Camera Calibration of a Penta-Camera

    Science.gov (United States)

    Jacobsen, K.; Gerke, M.

    2016-03-01

    Penta cameras consisting of a nadir and four inclined cameras are becoming more and more popular, having the advantage of imaging also facades in built up areas from four directions. Such system cameras require a boresight calibration of the geometric relation of the cameras to each other, but also a calibration of the sub-cameras. Based on data sets of the ISPRS/EuroSDR benchmark for multi platform photogrammetry the inner orientation of the used IGI Penta DigiCAM has been analyzed. The required image coordinates of the blocks Dortmund and Zeche Zollern have been determined by Pix4Dmapper and have been independently adjusted and analyzed by program system BLUH. With 4.1 million image points in 314 images respectively 3.9 million image points in 248 images a dense matching was provided by Pix4Dmapper. With up to 19 respectively 29 images per object point the images are well connected, nevertheless the high number of images per object point are concentrated to the block centres while the inclined images outside the block centre are satisfying but not very strongly connected. This leads to very high values for the Student test (T-test) of the finally used additional parameters or in other words, additional parameters are highly significant. The estimated radial symmetric distortion of the nadir sub-camera corresponds to the laboratory calibration of IGI, but there are still radial symmetric distortions also for the inclined cameras with a size exceeding 5μm even if mentioned as negligible based on the laboratory calibration. Radial and tangential effects of the image corners are limited but still available. Remarkable angular affine systematic image errors can be seen especially in the block Zeche Zollern. Such deformations are unusual for digital matrix cameras, but it can be caused by the correlation between inner and exterior orientation if only parallel flight lines are used. With exception of the angular affinity the systematic image errors for corresponding

  6. Evaluation of the pharmaceutical quality of some quinine preparations sold in Nigeria.

    Science.gov (United States)

    Nnamdi, Jolly A; Arhewoh, Ikhuoria M; Okhamafe, Augustine O; Enato, Ehijie F O

    2009-01-01

    The purpose of this study was to determine the pharmaceutical quality of quinine preparations sold in Nigerian markets. The organoleptic and physicochemical properties of quinine tablets, as well as oral liquids and parenteral quinine preparations, were assessed according to British Pharmacopoeia (BP) and unofficial standards as recommended by the manufacturers. Of the 6 brands of tablets assessed, 4 passed the uniformity of content test and 5 the disintegration test, but only 2 the dissolution test. The pH of 2 of the 6 brands of oral liquid preparations met BP standards, while only 1 oral liquid met the BP standard for percentage content. The assay further demonstrated that 4 brands of the parenteral preparations met BP standards for quinine content. All the parenteral preparations were found to be sterile. Quinine preparations sold in Nigeria varied considerably in their pharmaceutical quality. A strict check of the quality of brands of quinine by regulatory agencies and distributors before they are sold to the public is therefore recommended. Copyright 2009 S. Karger AG, Basel.

  7. Wild and native plants and mushrooms sold in the open-air markets of south-eastern Poland.

    Science.gov (United States)

    Kasper-Pakosz, Renata; Pietras, Marcin; Łuczaj, Łukasz

    2016-10-07

    The study of plants and fungi sold in open-air markets is an important part of ethnobotanical enquiry. Only few such studies were carried out in Europe. Four of the largest open-air markets of south-eastern Poland were visited regularly, and the plants sold in them were recorded between 2013 and 2015. The aim of the study was to record native and/or wild species sold in the markets. All the plants sold in the markets were photographed regularly. In each market, 25 sellers were interviewed. Voucher specimens were collected and fungi were identified using DNA barcoding. Altogether, 468 species of plants were recorded, 117 of them native to south-eastern Poland - 19 only collected from the wild and 11 both wild and cultivated. Seventeen of the species are under legal protection. Most protected plants were sold from cultivation, although proper authorization procedures had not been performed. Thirty-two species of fungi were sold (including two cultivated species), all of them for culinary purposes. Two species (Lactarius quieticolor, Leccinum schistophilum) are new to the mycobiota of Poland. Ornamental plants constituted a large section of the market, and they dominated the group of native species. Food plants dominated among wild-collected plants and were sold mainly as fruits for jams, juices and alcoholic drinks, or as culinary herbs. Very few medicinal or green vegetable plants were sold. An interesting feature of the markets was the sale of Ledum palustre as an insect repellent. Finding two species of fungi which are new to Poland highlights the importance of DNA barcoding in ethnomycological studies. Most items in the markets are ornamental plants, or edible fruits and mushrooms. Very few medicinal plants and green vegetables are sold, which differentiates the markets from southern European ones. Such a pattern is probably the model for most central European markets.

  8. Mid-IR Observations of Mira Circumstellar Environment

    OpenAIRE

    Marengo, Massimo; Karovska, Margarita; Fazio, Giovanni G.; Hora, Joseph L.; Hoffmann, William F.; Dayal, Aditya; Deutsch, Lynne K.

    2001-01-01

    This paper presents results from high-angular resolution mid-IR imaging of the Mira AB circumbinary environment using the MIRAC3 camera at the NASA Infrared Telescope Facility (IRTF). We resolved the dusty circumstellar envelope at 9.8, 11.7 and 18 micron around Mira A (o Ceti), and measured the size of the extended emission. Strong deviations from spherical symmetry are detected in the images of Mira AB system, including possible dust clumps in the direction of the companion (Mira B). These ...

  9. CCD and IR array controllers

    Science.gov (United States)

    Leach, Robert W.; Low, Frank J.

    2000-08-01

    A family of controllers has bene developed that is powerful and flexible enough to operate a wide range of CCD and IR focal plane arrays in a variety of ground-based applications. These include fast readout of small CCD and IR arrays for adaptive optics applications, slow readout of large CCD and IR mosaics, and single CCD and IR array operation at low background/low noise regimes as well as high background/high speed regimes. The CCD and IR controllers have a common digital core based on user- programmable digital signal processors that are used to generate the array clocking and signal processing signals customized for each application. A fiber optic link passes image data and commands to VME or PCI interface boards resident in a host computer to the controller. CCD signal processing is done with a dual slope integrator operating at speeds of up to one Megapixel per second per channel. Signal processing of IR arrays is done either with a dual channel video processor or a four channel video processor that has built-in image memory and a coadder to 32-bit precision for operating high background arrays. Recent developments underway include the implementation of a fast fiber optic data link operating at a speed of 12.5 Megapixels per second for fast image transfer from the controller to the host computer, and supporting image acquisition software and device drivers for the PCI interface board for the Sun Solaris, Linux and Windows 2000 operating systems.

  10. The fly's eye camera system

    Science.gov (United States)

    Mészáros, L.; Pál, A.; Csépány, G.; Jaskó, A.; Vida, K.; Oláh, K.; Mezö, G.

    2014-12-01

    We introduce the Fly's Eye Camera System, an all-sky monitoring device intended to perform time domain astronomy. This camera system design will provide complementary data sets for other synoptic sky surveys such as LSST or Pan-STARRS. The effective field of view is obtained by 19 cameras arranged in a spherical mosaic form. These individual cameras of the device stand on a hexapod mount that is fully capable of achieving sidereal tracking for the subsequent exposures. This platform has many advantages. First of all it requires only one type of moving component and does not include unique parts. Hence this design not only eliminates problems implied by unique elements, but the redundancy of the hexapod allows smooth operations even if one or two of the legs are stuck. In addition, it can calibrate itself by observed stars independently from both the geographical location (including northen and southern hemisphere) and the polar alignment of the full mount. All mechanical elements and electronics are designed within the confines of our institute Konkoly Observatory. Currently, our instrument is in testing phase with an operating hexapod and reduced number of cameras.

  11. Event detection intelligent camera development

    International Nuclear Information System (INIS)

    Szappanos, A.; Kocsis, G.; Molnar, A.; Sarkozi, J.; Zoletnik, S.

    2008-01-01

    A new camera system 'event detection intelligent camera' (EDICAM) is being developed for the video diagnostics of W-7X stellarator, which consists of 10 distinct and standalone measurement channels each holding a camera. Different operation modes will be implemented for continuous and for triggered readout as well. Hardware level trigger signals will be generated from real time image processing algorithms optimized for digital signal processor (DSP) and field programmable gate array (FPGA) architectures. At full resolution a camera sends 12 bit sampled 1280 x 1024 pixels with 444 fps which means 1.43 Terabyte over half an hour. To analyse such a huge amount of data is time consuming and has a high computational complexity. We plan to overcome this problem by EDICAM's preprocessing concepts. EDICAM camera system integrates all the advantages of CMOS sensor chip technology and fast network connections. EDICAM is built up from three different modules with two interfaces. A sensor module (SM) with reduced hardware and functional elements to reach a small and compact size and robust action in harmful environment as well. An image processing and control unit (IPCU) module handles the entire user predefined events and runs image processing algorithms to generate trigger signals. Finally a 10 Gigabit Ethernet compatible image readout card functions as the network interface for the PC. In this contribution all the concepts of EDICAM and the functions of the distinct modules are described

  12. Mock Target Window OTR and IR Design and Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wass, Alexander Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-19

    In order to fully verify temperature measurements made on the target window using infrared (IR) optical non-contact methods, actual comparative measurements are made with a real beam distribution as the heat source using Argonne National Laboratory’s (ANL) 35 MeV electron accelerator. Using Monte Carlo N-Particle (MCNP) simulations and thermal Finite Element Analysis (FEA), a cooled mock target window with thermocouple implants is designed to be used in such a test to achieve window temperatures up to 700°C. An uncoated and blackcoated mock window is designed to enhance the IR temperature measurements and verify optical transmitted radiation (OTR) imagery. This allows us to fully verify and characterize our temperature accuracy with our current IR camera method and any future method we may wish to explore using actual production conditions. This test also provides us with valuable conclusions/concerns regarding the calibration method we developed using our IR test stand at TA-53 in MPF-14.

  13. Video camera use at nuclear power plants

    International Nuclear Information System (INIS)

    Estabrook, M.L.; Langan, M.O.; Owen, D.E.

    1990-08-01

    A survey of US nuclear power plants was conducted to evaluate video camera use in plant operations, and determine equipment used and the benefits realized. Basic closed circuit television camera (CCTV) systems are described and video camera operation principles are reviewed. Plant approaches for implementing video camera use are discussed, as are equipment selection issues such as setting task objectives, radiation effects on cameras, and the use of disposal cameras. Specific plant applications are presented and the video equipment used is described. The benefits of video camera use --- mainly reduced radiation exposure and increased productivity --- are discussed and quantified. 15 refs., 6 figs

  14. The GISMO-2 Bolometer Camera

    Science.gov (United States)

    Staguhn, Johannes G.; Benford, Dominic J.; Fixsen, Dale J.; Hilton, Gene; Irwin, Kent D.; Jhabvala, Christine A.; Kovacs, Attila; Leclercq, Samuel; Maher, Stephen F.; Miller, Timothy M.; hide

    2012-01-01

    We present the concept for the GISMO-2 bolometer camera) which we build for background-limited operation at the IRAM 30 m telescope on Pico Veleta, Spain. GISM0-2 will operate Simultaneously in the 1 mm and 2 mm atmospherical windows. The 1 mm channel uses a 32 x 40 TES-based Backshort Under Grid (BUG) bolometer array, the 2 mm channel operates with a 16 x 16 BUG array. The camera utilizes almost the entire full field of view provided by the telescope. The optical design of GISM0-2 was strongly influenced by our experience with the GISMO 2 mm bolometer camera which is successfully operating at the 30m telescope. GISMO is accessible to the astronomical community through the regular IRAM call for proposals.

  15. Dark Energy Camera for Blanco

    Energy Technology Data Exchange (ETDEWEB)

    Binder, Gary A.; /Caltech /SLAC

    2010-08-25

    In order to make accurate measurements of dark energy, a system is needed to monitor the focus and alignment of the Dark Energy Camera (DECam) to be located on the Blanco 4m Telescope for the upcoming Dark Energy Survey. One new approach under development is to fit out-of-focus star images to a point spread function from which information about the focus and tilt of the camera can be obtained. As a first test of a new algorithm using this idea, simulated star images produced from a model of DECam in the optics software Zemax were fitted. Then, real images from the Mosaic II imager currently installed on the Blanco telescope were used to investigate the algorithm's capabilities. A number of problems with the algorithm were found, and more work is needed to understand its limitations and improve its capabilities so it can reliably predict camera alignment and focus.

  16. Perceptual Color Characterization of Cameras

    Directory of Open Access Journals (Sweden)

    Javier Vazquez-Corral

    2014-12-01

    Full Text Available Color camera characterization, mapping outputs from the camera sensors to an independent color space, such as \\(XYZ\\, is an important step in the camera processing pipeline. Until now, this procedure has been primarily solved by using a \\(3 \\times 3\\ matrix obtained via a least-squares optimization. In this paper, we propose to use the spherical sampling method, recently published by Finlayson al., to perform a perceptual color characterization. In particular, we search for the \\(3 \\times 3\\ matrix that minimizes three different perceptual errors, one pixel based and two spatially based. For the pixel-based case, we minimize the CIE \\(\\Delta E\\ error, while for the spatial-based case, we minimize both the S-CIELAB error and the CID error measure. Our results demonstrate an improvement of approximately 3for the \\(\\Delta E\\ error, 7& for the S-CIELAB error and 13% for the CID error measures.

  17. EDICAM (Event Detection Intelligent Camera)

    Energy Technology Data Exchange (ETDEWEB)

    Zoletnik, S. [Wigner RCP RMI, EURATOM Association, Budapest (Hungary); Szabolics, T., E-mail: szabolics.tamas@wigner.mta.hu [Wigner RCP RMI, EURATOM Association, Budapest (Hungary); Kocsis, G.; Szepesi, T.; Dunai, D. [Wigner RCP RMI, EURATOM Association, Budapest (Hungary)

    2013-10-15

    Highlights: ► We present EDICAM's hardware modules. ► We present EDICAM's main design concepts. ► This paper will describe EDICAM firmware architecture. ► Operation principles description. ► Further developments. -- Abstract: A new type of fast framing camera has been developed for fusion applications by the Wigner Research Centre for Physics during the last few years. A new concept was designed for intelligent event driven imaging which is capable of focusing image readout to Regions of Interests (ROIs) where and when predefined events occur. At present these events mean intensity changes and external triggers but in the future more sophisticated methods might also be defined. The camera provides 444 Hz frame rate at full resolution of 1280 × 1024 pixels, but monitoring of smaller ROIs can be done in the 1–116 kHz range even during exposure of the full image. Keeping space limitations and the harsh environment in mind the camera is divided into a small Sensor Module and a processing card interconnected by a fast 10 Gbit optical link. This camera hardware has been used for passive monitoring of the plasma in different devices for example at ASDEX Upgrade and COMPASS with the first version of its firmware. The new firmware and software package is now available and ready for testing the new event processing features. This paper will present the operation principle and features of the Event Detection Intelligent Camera (EDICAM). The device is intended to be the central element in the 10-camera monitoring system of the Wendelstein 7-X stellarator.

  18. The Sydney University PAPA camera

    Science.gov (United States)

    Lawson, Peter R.

    1994-04-01

    The Precision Analog Photon Address (PAPA) camera is a photon-counting array detector that uses optical encoding to locate photon events on the output of a microchannel plate image intensifier. The Sydney University camera is a 256x256 pixel detector which can operate at speeds greater than 1 million photons per second and produce individual photon coordinates with a deadtime of only 300 ns. It uses a new Gray coded mask-plate which permits a simplified optical alignment and successfully guards against vignetting artifacts.

  19. Streak cameras and their applications

    International Nuclear Information System (INIS)

    Bernet, J.M.; Imhoff, C.

    1987-01-01

    Over the last several years, development of various measurement techniques in the nanosecond and pico-second range has led to increased reliance on streak cameras. This paper will present the main electronic and optoelectronic performances of the Thomson-CSF TSN 506 cameras and their associated devices used to build an automatic image acquisition and processing system (NORMA). A brief survey of the diversity and the spread of the use of high speed electronic cinematography will be illustrated by a few typical applications [fr

  20. The recent and prospective developments of cooled IR FPAs for double application at Electron NRI

    Science.gov (United States)

    Arutunov, V. A.; Vasilyev, I. S.; Ivanov, V. G.; Prokofyev, A. E.

    2003-09-01

    The recent and prospective developments of monolithic silicon IR-Schottky-barrier staring focal plane arrays (IR SB FPAs), photodetector assembly, and digital thermal imaging cameras (TICs) at Electron National Research Institute (Electron NRI) are considered. Basic parameters for IR SB FPAs with 256x256 and 512x512 pixels, and TICs based on these arrays are presented. The problems emerged while proceeding from the developments of IR SB FPAs for the wavelength range from 3 μm to 5 μm to the developments of those ones for xLWIR range are indicated (an abrupt increase in the level of background architecture). Possibility for further improvement in basic parameters of IR SB FPAs are discussed (a decrease in threshold signal power down to 0.5-1.0"1013 W/element with an increase in quantum efficiency, a decrease in output noise and proceeding to Schottky barriers of degenerated semiconductor/silicon heterojunction, and implementation of these array parameters in photodetector assembly with improved thermal background shielding taking into consideration an optical structure of TIC for concrete application). It is concluded that relative simplicity of the technology and expected low cost of monolithic silicon IR SB FPAs with basic parameters compared with hybrid IR FPAs for the wavelength ranges from 3 μm to 5 μm and from 8 μm to 12 μm maintain large monolithic IR SB FPAs as a basis for developments of double application digital TICs in the Russian Federation.

  1. High-speed holographic camera

    International Nuclear Information System (INIS)

    Novaro, Marc

    The high-speed holographic camera is a disgnostic instrument using holography as an information storing support. It allows us to take 10 holograms, of an object, with exposures times of 1,5ns, separated in time by 1 or 2ns. In order to get these results easily, no mobile part is used in the set-up [fr

  2. The Camera Comes to Court.

    Science.gov (United States)

    Floren, Leola

    After the Lindbergh kidnapping trial in 1935, the American Bar Association sought to eliminate electronic equipment from courtroom proceedings. Eventually, all but two states adopted regulations applying that ban to some extent, and a 1965 Supreme Court decision encouraged the banning of television cameras at trials as well. Currently, some states…

  3. Gamma camera with reflectivity mask

    International Nuclear Information System (INIS)

    Stout, K.J.

    1980-01-01

    In accordance with the present invention there is provided a radiographic camera comprising: a scintillator; a plurality of photodectors positioned to face said scintillator; a plurality of masked regions formed upon a face of said scintillator opposite said photdetectors and positioned coaxially with respective ones of said photodetectors for decreasing the amount of internal reflection of optical photons generated within said scintillator. (auth)

  4. Multiple Sensor Camera for Enhanced Video Capturing

    Science.gov (United States)

    Nagahara, Hajime; Kanki, Yoshinori; Iwai, Yoshio; Yachida, Masahiko

    A resolution of camera has been drastically improved under a current request for high-quality digital images. For example, digital still camera has several mega pixels. Although a video camera has the higher frame-rate, the resolution of a video camera is lower than that of still camera. Thus, the high-resolution is incompatible with the high frame rate of ordinary cameras in market. It is difficult to solve this problem by a single sensor, since it comes from physical limitation of the pixel transfer rate. In this paper, we propose a multi-sensor camera for capturing a resolution and frame-rate enhanced video. Common multi-CCDs camera, such as 3CCD color camera, has same CCD for capturing different spectral information. Our approach is to use different spatio-temporal resolution sensors in a single camera cabinet for capturing higher resolution and frame-rate information separately. We build a prototype camera which can capture high-resolution (2588×1958 pixels, 3.75 fps) and high frame-rate (500×500, 90 fps) videos. We also proposed the calibration method for the camera. As one of the application of the camera, we demonstrate an enhanced video (2128×1952 pixels, 90 fps) generated from the captured videos for showing the utility of the camera.

  5. Impaired Insulin Signaling is Associated with Hepatic Mitochondrial Dysfunction in IR+/−-IRS-1+/− Double Heterozygous (IR-IRS1dh Mice

    Directory of Open Access Journals (Sweden)

    Andras Franko

    2017-05-01

    Full Text Available Mitochondria play a pivotal role in energy metabolism, but whether insulin signaling per se could regulate mitochondrial function has not been identified yet. To investigate whether mitochondrial function is regulated by insulin signaling, we analyzed muscle and liver of insulin receptor (IR+/−-insulin receptor substrate-1 (IRS-1+/− double heterozygous (IR-IRS1dh mice, a well described model for insulin resistance. IR-IRS1dh mice were studied at the age of 6 and 12 months and glucose metabolism was determined by glucose and insulin tolerance tests. Mitochondrial enzyme activities, oxygen consumption, and membrane potential were assessed using spectrophotometric, respirometric, and proton motive force analysis, respectively. IR-IRS1dh mice showed elevated serum insulin levels. Hepatic mitochondrial oxygen consumption was reduced in IR-IRS1dh animals at 12 months of age. Furthermore, 6-month-old IR-IRS1dh mice demonstrated enhanced mitochondrial respiration in skeletal muscle, but a tendency of impaired glucose tolerance. On the other hand, 12-month-old IR-IRS1dh mice showed improved glucose tolerance, but normal muscle mitochondrial function. Our data revealed that deficiency in IR/IRS-1 resulted in normal or even elevated skeletal muscle, but impaired hepatic mitochondrial function, suggesting a direct cross-talk between insulin signaling and mitochondria in the liver.

  6. Microbiological evaluation of drinking water sold by roadside vendors of Delhi, India

    Science.gov (United States)

    Chauhan, Abhishek; Goyal, Pankaj; Varma, Ajit; Jindal, Tanu

    2017-07-01

    Delhi has emerged as one of the greenest capital city of the world. Microbiological assessment of drinking water emphasizes estimation of the hygienic quality of the water sold with reference to community health significance. This study was conducted to evaluate the quality of drinking water sold by roadside vendors in east, west, north and south zones of capital of India. A total number of 36 samples (nine from each zone) were collected as per national guidelines and studied for microbiological assessment. All the drinking water samples were collected in gamma-sterilized bottles and were kept in an ice pack to prevent any significant change in the microbial flora of the samples during the transportation. The water samples were transported to the laboratory in vertical position maintaining the temperature 1-4 °C with ice pack enveloped conditions. Samples were analyzed for total MPN coliform per 100 ml and for the presence and absence of common human pathogenic bacteria such as Escherichia coli, Salmonella, Staphylococcus aureus and Pseudomonas aeruginosa. All the samples were found to be contaminated with coliform organisms in the range of 14 to >1600 per 100 ml of sample. Out of 36 water samples, the occurrence of E. coli was 61 %, Salmonella 25 % S. aureus 14 % and P. aeruginosa 53 % as 22, 9, 5 and 19 samples were found contaminated, respectively. The numbers of coliform bacteria and presence of some common pathogenic bacteria suggested that the quality of drinking water sold by roadside vendors is not within the Indian standard and WHO guidelines laid down for drinking water quality. Hence, there is a vital need to study the root cause in terms of hygiene, sanitation of vendors and source of contamination to prevent waterborne diseases.

  7. Contribution To The Data Warehouse And Prospects Of The IRS Program

    Science.gov (United States)

    Barner, Frithjof; Haydn, Rupert; Parmar, Manish; Makiola, Jens

    2013-12-01

    Over the past two years, the IRS program has again significantly contributed to the GSC-DA Data Warehouse. From its suite of optical EO satellites which operate in the visible, near IR and shortwave IR domain, multispectral data from the HR LISS-III and MR AWiFS sensors have been provided. Both cameras are implemented on board of Resourcesat-1 and Resourcesat-2 respectively. Despite reduced capacities, the Resourcesat constellation of satellites so far acquired cloud-free images of a vast majority of the first HR coverage of CORE_001 and several monthly MR coverages for CORE_008 over the EEA-39. The results regarding the above mentioned data sets will be discussed including an appraisal of the possible future role of upcoming IRS EO satellites for European data requirements.

  8. Optimal Overhaul-Replacement Policies for Repairable Machine Sold with Warranty

    OpenAIRE

    Soemadi, Kusmaningrum; Iskandar, Bermawi P; Taroepratjeka, Harsono

    2014-01-01

    This research deals with an overhaul-replacement policy for a repairable machine sold with Free Replacement Warranty (FRW). The machine will be used for a finite horizon, T (T <), and evaluated at a fixed interval, s (s< T). At each evaluation point, the buyer considers three alternative decisions i.e. Keep the machine, Overhaul it, or Replace it with a new identical one. An overhaul can reduce the machine age virtually, but not to a point that the machine is as good as new. If the mac...

  9. SALMONELLA SPECIE AND TOTAL VIABLE BACTERIAL LOAD IN ROASTED CHICKENS SOLD IN JOS-NIGERIA

    OpenAIRE

    Carol Okoli; Okonji M.C; Ugoh S.C; Okolo S.N; Okoli A.C; Alu A.J

    2007-01-01

    The study was to investigate for the presence of Salmonella specie and total viable aerobic bacterial load in roasted chickens sold in Jos. The study was carried out on twenty five chicken samples. No salmonella specie was isolated from the samples. However, other bacterial organisms were isolates, viz: 9(36%) of the samples yielded E.coli; 5(20%) yielded Citobacter species; 3(12%) yielded Proteus species and 6(24%) yielded Klebsiella species while 2(8%) showed no growth. An average total via...

  10. Using IR Imaging of Water Surfaces for Estimating Piston Velocities

    Science.gov (United States)

    Gålfalk, M.; Bastviken, D.; Arneborg, L.

    2013-12-01

    The transport of gasses dissolved in surface waters across the water-atmosphere interface is controlled by the piston velocity (k). This coefficient has large implications for, e.g., greenhouse gas fluxes but is challenging to quantify in situ. At present, empirical k-wind speed relationships from a small number of studies and systems are often extrapolated without knowledge of model performance. It is therefore of interest to search for new methods for estimating k, and to compare the pros and cons of existing and new methods. Wind speeds in such models are often measured at a height of 10 meters. In smaller bodies of water such as lakes, wind speeds can vary dramatically across the surface through varying degrees of wind shadow from e.g. trees at the shoreline. More local measurements of the water surface, through wave heights or surface motion mapping, could give improved k-estimates over a surface, also taking into account wind fetch. At thermal infrared (IR) wavelengths water has very low reflectivity (depending on viewing angle) than can go below 1%, meaning that more than 99% is heat radiation giving a direct measurement of surface temperature variations. Using an IR camera at about 100 frames/s one could map surface temperature structures at a fraction of a mm depth even with waves present. In this presentation I will focus on IR imaging as a possible tool for estimating piston velocities. Results will be presented from IR field measurements, relating the motions of surface temperature structures to k calculated from other simultaneous measurements (flux chamber and ADV-Based Dissipation Rate), but also attempting to calculate k directly from the IR surface divergence. A relation between wave height and k will also be presented.

  11. Broadly tunable picosecond ir source

    International Nuclear Information System (INIS)

    Campillo, A.J.; Hyer, R.C.; Shapiro, S.L.

    1979-01-01

    A completely grating tuned (1.9 to 2.4 μm) picosecond traveling wave IR generator capable of controlled spectral bandwidth operation down to the Fourier Transform limit is reported. Subsequent down conversion in CdSe extends tuning to 10 to 20 μm

  12. Architectural Design Document for Camera Models

    DEFF Research Database (Denmark)

    Thuesen, Gøsta

    1998-01-01

    Architecture of camera simulator models and data interface for the Maneuvering of Inspection/Servicing Vehicle (MIV) study.......Architecture of camera simulator models and data interface for the Maneuvering of Inspection/Servicing Vehicle (MIV) study....

  13. Selecting a digital camera for telemedicine.

    Science.gov (United States)

    Patricoski, Chris; Ferguson, A Stewart

    2009-06-01

    The digital camera is an essential component of store-and-forward telemedicine (electronic consultation). There are numerous makes and models of digital cameras on the market, and selecting a suitable consumer-grade camera can be complicated. Evaluation of digital cameras includes investigating the features and analyzing image quality. Important features include the camera settings, ease of use, macro capabilities, method of image transfer, and power recharging. Consideration needs to be given to image quality, especially as it relates to color (skin tones) and detail. It is important to know the level of the photographer and the intended application. The goal is to match the characteristics of the camera with the telemedicine program requirements. In the end, selecting a digital camera is a combination of qualitative (subjective) and quantitative (objective) analysis. For the telemedicine program in Alaska in 2008, the camera evaluation and decision process resulted in a specific selection based on the criteria developed for our environment.

  14. 21 CFR 886.1120 - Opthalmic camera.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1120 Opthalmic camera. (a) Identification. An ophthalmic camera is an AC-powered device intended to take photographs of the eye and the surrounding area...

  15. Alkoholio ir tabako pasiūlos ir paklausos teisinio reguliavimo raida Lietuvos Respublikoje: problemos ir sprendimai

    OpenAIRE

    Mockevičius, Arminas

    2014-01-01

    Viešosios teisės magistro studijų programos studento Armino Mockevičiaus buvo parašytas magistro baigiamasis darbas „Alkoholio ir tabako pasiūlos ir paklausos teisinio reguliavimo raida Lietuvos Respublikoje: problemos ir sprendimai“. Šis darbas parašytas Vilniuje, 2014 metais, Mykolo Romerio universiteto Teisės fakulteto Konstitucinės ir administracinės teisės institute, vadovaujant dr. Gintautui Vilkeliui, apimtis 98 p. Darbo tikslas yra atskleisti alkoholio ir tabako pasiūlos ir paklau...

  16. Improved positron emission tomography camera

    International Nuclear Information System (INIS)

    Mullani, N.A.

    1986-01-01

    A positron emission tomography camera having a plurality of rings of detectors positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom, and a plurality of scintillation crystals positioned relative to the photomultiplier tubes whereby each tube is responsive to more than one crystal. Each alternate crystal in the ring may be offset by one-half or less of the thickness of the crystal such that the staggered crystals are seen by more than one photomultiplier tube. This sharing of crystals and photomultiplier tubes allows identification of the staggered crystal and the use of smaller detectors shared by larger photomultiplier tubes thereby requiring less photomultiplier tubes, creating more scanning slices, providing better data sampling, and reducing the cost of the camera. (author)

  17. Vehicular camera pedestrian detection research

    Science.gov (United States)

    Liu, Jiahui

    2018-03-01

    With the rapid development of science and technology, it has made great development, but at the same time of highway traffic more convenient in highway traffic and transportation. However, in the meantime, traffic safety accidents occur more and more frequently in China. In order to deal with the increasingly heavy traffic safety. So, protecting the safety of people's personal property and facilitating travel has become a top priority. The real-time accurate pedestrian and driving environment are obtained through a vehicular camera which are used to detection and track the preceding moving targets. It is popular in the domain of intelligent vehicle safety driving, autonomous navigation and traffic system research. Based on the pedestrian video obtained by the Vehicular Camera, this paper studies the trajectory of pedestrian detection and its algorithm.

  18. Evaluation of Parasitic Pollution in Fresh Unwashed Herbs Sold in Izeh City, Iran

    Directory of Open Access Journals (Sweden)

    Valipour Nouroozi

    2015-11-01

    Full Text Available Background Fresh herbs are a crucial part of a good diet. However, they can easily become contaminated with food-borne pathogens. Eating fresh unwashed or improperly washed herbs has a major role in transmission of some important parasitic diseases. Objectives This study was carried out to evaluate parasitic pollution in fresh unwashed herbs sold in Izeh city, Iran. Materials and Methods Four hundred samples of fresh unwashed herbs were purchased from a distributor in Izeh city during January 2014 to April 2015. Detergent solution was added to 240 g of each sample. The mixture was shaken and washed solution was filtered through 0.2 µm bottle-top filter. The filtrate was discarded and filter was placed in a 50 mL conical screw cap tube. Then, the detergent solution was added. Following vortex, filter was discarded. The sediment was examined by light microscope after centrifuge. Finally, data descriptive analyses were carried out. Results Parasitic pollution was detected in 3.5% of the examined samples, including Cryptosporidium spp. oocyst (1.5%, Giardia spp. cyst (1%, Blastocystis spp. cyst (0.5% and Taenia spp. egg (0.5%. Conclusions Parasitic contamination of fresh herbs sold in Izeh may pose a health risk to consumers if eaten as unwashed or improperly washed.

  19. Detection of genetically modified DNA in fresh and processed foods sold in Kuwait.

    Science.gov (United States)

    Al-Salameen, Fadila; Kumar, Vinod; Al-Aqeel, Hamed; Al-Hashash, Hanadi; Hejji, Ahmed Bin

    2012-01-01

    Developments in genetic engineering technology have led to an increase in number of food products that contain genetically engineered crops in the global market. However, due to lack of scientific studies, the presence of genetically modified organisms (GMOs) in the Kuwaiti food market is currently ambiguous. Foods both for human and animal consumption are being imported from countries that are known to produce GM food. Therefore, an attempt has been made to screen foods sold in the Kuwaiti market to detect GMOs in the food. For this purpose, samples collected from various markets in Kuwait have been screened by SYBR green-based real time polymerase chain reaction (RT-PCR) method. Further confirmation and GMO quantification was performed by TaqMan-based RT-PCR. Results indicated that a significant number of food commodities sold in Kuwait were tested positive for the presence of GMO. Interestingly, certain processed foods were tested positive for more than one transgenic events showing complex nature of GMOs in food samples. Results of this study clearly indicate the need for well-defined legislations and regulations on the marketing of approved GM food and its labeling to protect consumer's rights.

  20. Lead content of dried films of domestic paints currently sold in Nigeria

    International Nuclear Information System (INIS)

    Adebamowo, Eugenious O.; Scott Clark, C.; Roda, Sandy; Agbede, Oluwole A.; Sridhar, Mynepalli K.C.; Adebamowo, Clement A.

    2007-01-01

    Children are at higher risk from lead exposure because their developing neural system is susceptible to its neurotoxic effects. We studied lead levels of paints manufactured in Nigeria in 2006. Lead levels in 5 colors of paints, each from different manufacturers were measured using flame-atomic absorption spectroscopy. We found that 96% of the paints had higher than recommended levels of lead. The mean lead level of paints ranged from 84.8 to 50,000 ppm, with mean of 14,500 ppm and median of 15,800 ppm. The main determinant of lead levels was color of the paint. As lead levels in paint sold in the past years in Nigeria are likely to be at least as high as that currently sold, it is likely that many existing houses contain dangerously high levels of lead. Efforts need to be undertaken to assess the presence of high lead levels in existing housing and if detected, intervention programs for eliminating risk of exposure should be developed in addition to measures to increase awareness and enforce regulations leading to the elimination of lead based domestic paint

  1. KAJIAN TERHADAP BEBERAPA METODE PENYUSUTAN DAN PENGARUHNYA TERHADAP PERHITUNGAN BEBAN POKOK PENJUALAN (COST OF GOOD SOLD

    Directory of Open Access Journals (Sweden)

    Juniady Slamed Setiawan

    2001-01-01

    Full Text Available Every company must generate financial statement, that provide information about income, changes in financial position to whom that concerned. In preparing financial statement, each company has a power to choose the accounting methods and technics that recommended by Financial Accounting Standard. Accounting policies adopted by firm has a substanstial impact in financial statement.Therefore the company that has equal performance will report different result.This article try to present the impact of choosing depreciation method in calculating cost of goods sold. Abstract in Bahasa Indonesia : Setiap perusahaan wajib menerbitkan laporan keuangan, yang memberikan informasi mengenai hasil usaha, perubahan posisi keuangan kepada pihak yang memerlukan. Dalam menyusun laporan keuangan, perusahaan memiliki keleluasaan untuk memilih metode dan teknik sepanjang metode yang dipilih tersebut ada dalam SAK (Standar Akuntansi Keuangan. Pemilihan metode akuntansi memiliki dampak yang sangat besar terhadap laporan keuangan yang dihasilkan. Dengan demikian dimungkinkan perusahaan yang sebenarnya memiliki kinerja yang sama dapat melaporkan hasil yang berbeda. Tulisan ini mencoba untuk mengetengahkan dampak pemilihan metode penyusutan terhadap perhitungan beban pokok penjualan (cost of goods sold. Kata kunci: metode penyusutan, beban penyusutan, aktiva tetap, beban pokok penjualan.

  2. Palytoxin found in Palythoa sp. zoanthids (Anthozoa, Hexacorallia sold in the home aquarium trade.

    Directory of Open Access Journals (Sweden)

    Jonathan R Deeds

    2011-04-01

    Full Text Available Zoanthids (Anthozoa, Hexacorallia are colonial anemones that contain one of the deadliest toxins ever discovered, palytoxin (LD(50 in mice 300 ng/kg, but it is generally believed that highly toxic species are not sold in the home aquarium trade. We previously showed that an unintentionally introduced zoanthid in a home aquarium contained high concentrations of palytoxin and was likely responsible for a severe respiratory reaction when an individual attempted to eliminate the contaminant colonies using boiling water. To assess the availability and potential exposure of palytoxin to marine aquarium hobbyists, we analyzed zoanthid samples collected from local aquarium stores for palytoxin using liquid chromatography and high resolution mass spectrometry and attempted to identify the specimens through genetic analysis of 16S and cytochrome c oxidase 1 (COI markers. We found four specimens of the same apparent species of zoanthid, that we described previously to be responsible for a severe respiratory reaction in a home aquarium, to be available in three aquarium stores in the Washington D.C. area. We found all of these specimens (n = 4 to be highly toxic with palytoxin or palytoxin-like compounds (range 0.5-3.5 mg crude toxin/g zoanthid. One of the most potent non-protein compounds ever discovered is present in dangerous quantities in a select species of zoanthid commonly sold in the home aquarium trade.

  3. Palytoxin found in Palythoa sp. zoanthids (Anthozoa, Hexacorallia) sold in the home aquarium trade.

    Science.gov (United States)

    Deeds, Jonathan R; Handy, Sara M; White, Kevin D; Reimer, James D

    2011-04-04

    Zoanthids (Anthozoa, Hexacorallia) are colonial anemones that contain one of the deadliest toxins ever discovered, palytoxin (LD(50) in mice 300 ng/kg), but it is generally believed that highly toxic species are not sold in the home aquarium trade. We previously showed that an unintentionally introduced zoanthid in a home aquarium contained high concentrations of palytoxin and was likely responsible for a severe respiratory reaction when an individual attempted to eliminate the contaminant colonies using boiling water. To assess the availability and potential exposure of palytoxin to marine aquarium hobbyists, we analyzed zoanthid samples collected from local aquarium stores for palytoxin using liquid chromatography and high resolution mass spectrometry and attempted to identify the specimens through genetic analysis of 16S and cytochrome c oxidase 1 (COI) markers. We found four specimens of the same apparent species of zoanthid, that we described previously to be responsible for a severe respiratory reaction in a home aquarium, to be available in three aquarium stores in the Washington D.C. area. We found all of these specimens (n = 4) to be highly toxic with palytoxin or palytoxin-like compounds (range 0.5-3.5 mg crude toxin/g zoanthid). One of the most potent non-protein compounds ever discovered is present in dangerous quantities in a select species of zoanthid commonly sold in the home aquarium trade.

  4. Microbial assessment of un-bottled synthetic juices sold in Peshawar

    International Nuclear Information System (INIS)

    Abid, H.; Ali, J.; Hussain, A.

    2010-01-01

    Un-bottled synthetic juices are sold by street vendors and hawkers raising the concern about their safety. To examine the quality of un-bottled synthetic beverages from different locations of Peshawar city using Standard techniques. A total of 56 samples of un-bottled synthetic juices were collected from 8 different locations of Peshawar City and analyzed for Total Plate Count, Total Coliform Bacteria, Total Fecal Coliform bacteria E. coli, Yeast and Mould. In all localities, the street vended un-bottled synthetic juices were found hygienically of poor quality as all had high total plate count which ranged from 2 x 102 to 5 x 107 and total coliform bacteria ranged from 110 MPN/ml. Total Fecal Coliform ranged from < 0.3 to 110M PN/ml. The presence of E coli, contamination was found in (25) 44 % Samples, while all the analyzed samples were contaminated with yeasts and moulds. All un-bottled synthetic juices sold on roadside were highly contaminated with disease causing microorganisms. Policy message: Periodic monitoring of street beverage should be carried out to make them safe for consumption. (author)

  5. Graphic design of pinhole cameras

    Science.gov (United States)

    Edwards, H. B.; Chu, W. P.

    1979-01-01

    The paper describes a graphic technique for the analysis and optimization of pinhole size and focal length. The technique is based on the use of the transfer function of optical elements described by Scott (1959) to construct the transfer function of a circular pinhole camera. This transfer function is the response of a component or system to a pattern of lines having a sinusoidally varying radiance at varying spatial frequencies. Some specific examples of graphic design are presented.

  6. The MVACS Robotic Arm Camera

    Science.gov (United States)

    Keller, H. U.; Hartwig, H.; Kramm, R.; Koschny, D.; Markiewicz, W. J.; Thomas, N.; Fernades, M.; Smith, P. H.; Reynolds, R.; Lemmon, M. T.; Weinberg, J.; Marcialis, R.; Tanner, R.; Boss, B. J.; Oquest, C.; Paige, D. A.

    2001-08-01

    The Robotic Arm Camera (RAC) is one of the key instruments newly developed for the Mars Volatiles and Climate Surveyor payload of the Mars Polar Lander. This lightweight instrument employs a front lens with variable focus range and takes images at distances from 11 mm (image scale 1:1) to infinity. Color images with a resolution of better than 50 μm can be obtained to characterize the Martian soil. Spectral information of nearby objects is retrieved through illumination with blue, green, and red lamp sets. The design and performance of the camera are described in relation to the science objectives and operation. The RAC uses the same CCD detector array as the Surface Stereo Imager and shares the readout electronics with this camera. The RAC is mounted at the wrist of the Robotic Arm and can characterize the contents of the scoop, the samples of soil fed to the Thermal Evolved Gas Analyzer, the Martian surface in the vicinity of the lander, and the interior of trenches dug out by the Robotic Arm. It can also be used to take panoramic images and to retrieve stereo information with an effective baseline surpassing that of the Surface Stereo Imager by about a factor of 3.

  7. Development of Strained-Layer Superlattice (SLS) IR Detector Camera Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Strained Layer Superlattice (SLS) detectors are a new class of detectors which may be the next generation of band-gap engineered, large format infrared detector...

  8. Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System

    Science.gov (United States)

    Hudson, Troy L.; Hecht, Michael H.

    2011-01-01

    As shown by the Phoenix Mars Lander's Thermal and Electrical Conductivity Probe (TECP), contact measurements of thermal conductivity and diffusivity (using a modified flux-plate or line-source heat-pulse method) are constrained by a number of factors. Robotic resources must be used to place the probe, making them unavailable for other operations for the duration of the measurement. The range of placement is also limited by mobility, particularly in the case of a lander. Placement is also subject to irregularities in contact quality, resulting in non-repeatable heat transfer to the material under test. Most important from a scientific perspective, the varieties of materials which can be measured are limited to unconsolidated or weakly-cohesive regolith materials, rocks, and ices being too hard for nominal insertion strengths. Accurately measuring thermal properties in the laboratory requires significant experimental finesse, involving sample preparation, controlled and repeatable procedures, and, practically, instrumentation much more voluminous than the sample being tested (heater plates, insulation, temperature sensors). Remote measurements (infrared images from orbiting spacecraft) can reveal composite properties like thermal inertia, but suffer both from a large footprint (low spatial resolution) and convolution of the thermal properties of a potentially layered medium. In situ measurement techniques (the Phoenix TECP is the only robotic measurement of thermal properties to date) suffer from problems of placement range, placement quality, occupation of robotic resources, and the ability to only measure materials of low mechanical strength. A spacecraft needs the ability to perform a non-contact thermal properties measurement in situ. Essential components include low power consumption, leveraging of existing or highly-developed flight technologies, and mechanical simplicity. This new in situ method, by virtue of its being non-contact, bypasses all of these problems. The use of photons to both excite and measure the thermal response of any surface material to a high resolution (estimated footprint = 10 square centimeters) is a generational leap in physical properties measurements. The proposed method consists of spot-heating the surface of a material with a low (less than 1 W) power laser. This produces a moderate (5-10 K) temperature increase in the material.

  9. Porcine Skin Thermal Response to Near-IR Lasers Using a Fast Infrared Camera

    National Research Council Canada - National Science Library

    Cain, Clarence; Milner, Thomas; Telenkov, Sergey; Schuster, Kurt; Stockton, Kevin; Stolarski, David; Condit, Chris; Rockwell, Ben; Roach, William; Welch, A. J

    2004-01-01

    ... of 1.3 mm diameter gave approximately a 43 degrees C rise at a hot spot. Computed temperature distributions as a function of time and space are presented and compared with the measured surface temperatures.

  10. IR Camera Validation of IGBT Junction Temperature Measurement via Peak Gate Current

    DEFF Research Database (Denmark)

    Baker, Nick; Dupont, Laurent; Munk-Nielsen, Stig

    2017-01-01

    partial bond-wire lift-off. Results are also compared with a traditional electrical temperature measurement method: the voltage drop under low current (VCE(low)). In all cases, the IGPeak method is found to provide a temperature slightly overestimating the temperature of the gate pad. Consequently, both...... the gate pad position and chip temperature distribution influence whether the measurement is representative of the mean junction temperature. These results remain consistent after chips are degraded through bondwire lift-off. In a paralleled IGBT configuration with non-negligible temperature disequilibrium...

  11. 16 CFR 501.1 - Camera film.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Camera film. 501.1 Section 501.1 Commercial... 500 § 501.1 Camera film. Camera film packaged and labeled for retail sale is exempt from the net... should be expressed, provided: (a) The net quantity of contents on packages of movie film and bulk still...

  12. An Open Standard for Camera Trap Data

    NARCIS (Netherlands)

    Forrester, Tavis; O'Brien, Tim; Fegraus, Eric; Jansen, P.A.; Palmer, Jonathan; Kays, Roland; Ahumada, Jorge; Stern, Beth; McShea, William

    2016-01-01

    Camera traps that capture photos of animals are a valuable tool for monitoring biodiversity. The use of camera traps is rapidly increasing and there is an urgent need for standardization to facilitate data management, reporting and data sharing. Here we offer the Camera Trap Metadata Standard as an

  13. A camera specification for tendering purposes

    International Nuclear Information System (INIS)

    Lunt, M.J.; Davies, M.D.; Kenyon, N.G.

    1985-01-01

    A standardized document is described which is suitable for sending to companies which are being invited to tender for the supply of a gamma camera. The document refers to various features of the camera, the performance specification of the camera, maintenance details, price quotations for various options and delivery, installation and warranty details. (U.K.)

  14. Kinect Fusion improvement using depth camera calibration

    Science.gov (United States)

    Pagliari, D.; Menna, F.; Roncella, R.; Remondino, F.; Pinto, L.

    2014-06-01

    Scene's 3D modelling, gesture recognition and motion tracking are fields in rapid and continuous development which have caused growing demand on interactivity in video-game and e-entertainment market. Starting from the idea of creating a sensor that allows users to play without having to hold any remote controller, the Microsoft Kinect device was created. The Kinect has always attract researchers in different fields, from robotics to Computer Vision (CV) and biomedical engineering as well as third-party communities that have released several Software Development Kit (SDK) versions for Kinect in order to use it not only as a game device but as measurement system. Microsoft Kinect Fusion control libraries (firstly released in March 2013) allow using the device as a 3D scanning and produce meshed polygonal of a static scene just moving the Kinect around. A drawback of this sensor is the geometric quality of the delivered data and the low repeatability. For this reason the authors carried out some investigation in order to evaluate the accuracy and repeatability of the depth measured delivered by the Kinect. The paper will present a throughout calibration analysis of the Kinect imaging sensor, with the aim of establishing the accuracy and precision of the delivered information: a straightforward calibration of the depth sensor in presented and then the 3D data are correct accordingly. Integrating the depth correction algorithm and correcting the IR camera interior and exterior orientation parameters, the Fusion Libraries are corrected and a new reconstruction software is created to produce more accurate models.

  15. Kinect Fusion improvement using depth camera calibration

    Directory of Open Access Journals (Sweden)

    D. Pagliari

    2014-06-01

    Full Text Available Scene's 3D modelling, gesture recognition and motion tracking are fields in rapid and continuous development which have caused growing demand on interactivity in video-game and e-entertainment market. Starting from the idea of creating a sensor that allows users to play without having to hold any remote controller, the Microsoft Kinect device was created. The Kinect has always attract researchers in different fields, from robotics to Computer Vision (CV and biomedical engineering as well as third-party communities that have released several Software Development Kit (SDK versions for Kinect in order to use it not only as a game device but as measurement system. Microsoft Kinect Fusion control libraries (firstly released in March 2013 allow using the device as a 3D scanning and produce meshed polygonal of a static scene just moving the Kinect around. A drawback of this sensor is the geometric quality of the delivered data and the low repeatability. For this reason the authors carried out some investigation in order to evaluate the accuracy and repeatability of the depth measured delivered by the Kinect. The paper will present a throughout calibration analysis of the Kinect imaging sensor, with the aim of establishing the accuracy and precision of the delivered information: a straightforward calibration of the depth sensor in presented and then the 3D data are correct accordingly. Integrating the depth correction algorithm and correcting the IR camera interior and exterior orientation parameters, the Fusion Libraries are corrected and a new reconstruction software is created to produce more accurate models.

  16. Relative camera localisation in non-overlapping camera networks using multiple trajectories

    NARCIS (Netherlands)

    John, V.; Englebienne, G.; Kröse, B.J.A.

    2012-01-01

    In this article we present an automatic camera calibration algorithm using multiple trajectories in a multiple camera network with non-overlapping field-of-views (FOV). Visible trajectories within a camera FOV are assumed to be measured with respect to the camera local co-ordinate system.

  17. A ToF-Camera as a 3D Vision Sensor for Autonomous Mobile Robotics

    Directory of Open Access Journals (Sweden)

    Sobers Lourdu Xavier Francis

    2015-11-01

    Full Text Available The aim of this paper is to deploy a time-of-flight (ToF based photonic mixer device (PMD camera on an Autonomous Ground Vehicle (AGV whose overall target is to traverse from one point to another in hazardous and hostile environments employing obstacle avoidance without human intervention. The hypothesized approach of applying a ToF Camera for an AGV is a suitable approach to autonomous robotics because, as the ToF camera can provide three-dimensional (3D information at a low computational cost, it is utilized to extract information about obstacles after their calibration and ground testing and is mounted and integrated with the Pioneer mobile robot. The workspace is a two-dimensional (2D world map which has been divided into a grid/cells, where the collision-free path defined by the graph search algorithm is a sequence of cells the AGV can traverse to reach the target. PMD depth data is used to populate traversable areas and obstacles by representing a grid/cells of suitable size. These camera data are converted into Cartesian coordinates for entry into a workspace grid map. A more optimal camera mounting angle is needed and adopted by analysing the camera's performance discrepancy, such as pixel detection, the detection rate and the maximum perceived distances, and infrared (IR scattering with respect to the ground surface. This mounting angle is recommended to be half the vertical field-of-view (FoV of the PMD camera. A series of still and moving tests are conducted on the AGV to verify correct sensor operations, which show that the postulated application of the ToF camera in the AGV is not straightforward. Later, to stabilize the moving PMD camera and to detect obstacles, a tracking feature detection algorithm and the scene flow technique are implemented to perform a real-time experiment.

  18. Comparing light sensitivity, linearity and step response of electronic cameras for ophthalmology.

    Science.gov (United States)

    Kopp, O; Markert, S; Tornow, R P

    2002-01-01

    To develop and test a procedure to measure and compare light sensitivity, linearity and step response of electronic cameras. The pixel value (PV) of digitized images as a function of light intensity (I) was measured. The sensitivity was calculated from the slope of the P(I) function, the linearity was estimated from the correlation coefficient of this function. To measure the step response, a short sequence of images was acquired. During acquisition, a light source was switched on and off using a fast shutter. The resulting PV was calculated for each video field of the sequence. A CCD camera optimized for the near-infrared (IR) spectrum showed the highest sensitivity for both, visible and IR light. There are little differences in linearity. The step response depends on the procedure of integration and read out.

  19. Oferta ir akceptas vartojimo sutartyse

    OpenAIRE

    Ežerskytė, Ramunė

    2011-01-01

    Sutarčiai sudaryti paprastai reikia, kad viena šalis pasiūlytų sudaryti sutartį (oferta), o kita šalis sutiktų su pasiūlymu (akceptas). Sutarčių įvairovėje išskiriamos vartojimo sutartys, kurios dėl silpnesnės šalies apsaugos principo įgyvendinimo pasižymi tam tikrais ypatumais. Vartojimo sutarčių sudarymas pateikiant ofertą ir akceptą yra šio magistro baigiamojo darbo objektas. Magistro baigiamąjį darbą sudaro trys dalys. Pirmojoje darbo dalyje analizuojama vartojimo sutarties sąvoka ir spec...

  20. Stereo Pinhole Camera: Assembly and experimental activities

    Directory of Open Access Journals (Sweden)

    Gilmário Barbosa Santos

    2015-05-01

    Full Text Available This work describes the assembling of a stereo pinhole camera for capturing stereo-pairs of images and proposes experimental activities with it. A pinhole camera can be as sophisticated as you want, or so simple that it could be handcrafted with practically recyclable materials. This paper describes the practical use of the pinhole camera throughout history and currently. Aspects of optics and geometry involved in the building of the stereo pinhole camera are presented with illustrations. Furthermore, experiments are proposed by using the images obtained by the camera for 3D visualization through a pair of anaglyph glasses, and the estimation of relative depth by triangulation is discussed.

  1. Single Camera Calibration in 3D Vision

    Directory of Open Access Journals (Sweden)

    Caius SULIMAN

    2009-12-01

    Full Text Available Camera calibration is a necessary step in 3D vision in order to extract metric information from 2D images. A camera is considered to be calibrated when the parameters of the camera are known (i.e. principal distance, lens distorsion, focal length etc.. In this paper we deal with a single camera calibration method and with the help of this method we try to find the intrinsic and extrinsic camera parameters. The method was implemented with succes in the programming and simulation environment Matlab.

  2. Climate Prediction Center IR 4km Dataset

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — CPC IR 4km dataset was created from all available individual geostationary satellite data which have been merged to form nearly seamless global (60N-60S) IR...

  3. Leveraging corporate social responsibility to improve consumer safety of dietary supplements sold for weight loss and muscle building.

    Science.gov (United States)

    Kulkarni, Anvita; Huerto, Ryan; Roberto, Christina A; Austin, S Bryn

    2017-03-01

    The potential dangers associated with dietary supplements sold for weight loss and muscle building are well documented and increasingly garnering the attention of the media, public, and government leaders. Public health professionals have an opportunity to improve population health in the context of dietary supplement use by translating scientific evidence into action. In this commentary, we discuss the potential to motivate corporate social responsibility (CSR) among manufacturers and retailers of dietary supplements sold for weight loss and muscle building. We examine levers available to public health professionals for generating voluntary corporate self-regulation by reviewing examples from successful CSR initiatives in other domains of public health and offering recommendations highlighting effective advocacy strategies. We encourage public health professionals to use one or multiple advocacy strategies to improve consumer protections for dietary supplements sold for weight loss and muscle building.

  4. MTF measurement of IR optics in different temperature ranges

    Science.gov (United States)

    Bai, Alexander; Duncker, Hannes; Dumitrescu, Eugen

    2017-10-01

    Infrared (IR) optical systems are at the core of many military, civilian and manufacturing applications and perform mission critical functions. To reliably fulfill the demanding requirements imposed on today's high performance IR optics, highly accurate, reproducible and fast lens testing is of crucial importance. Testing the optical performance within different temperature ranges becomes key in many military applications. Due to highly complex IR-Applications in the fields of aerospace, military and automotive industries, MTF Measurement under realistic environmental conditions become more and more relevant. A Modulation Transfer Function (MTF) test bench with an integrated thermal chamber allows measuring several sample sizes in a temperature range from -40 °C to +120°C. To reach reliable measurement results under these difficult conditions, a specially developed temperature stable design including an insulating vacuum are used. The main function of this instrument is the measurement of the MTF both on- and off-axis at up to +/-70° field angle, as well as measurement of effective focal length, flange focal length and distortion. The vertical configuration of the system guarantees a small overall footprint. By integrating a high-resolution IR camera with focal plane array (FPA) in the detection unit, time consuming measurement procedures such as scanning slit with liquid nitrogen cooled detectors can be avoided. The specified absolute accuracy of +/- 3% MTF is validated using internationally traceable reference optics. Together with a complete and intuitive software solution, this makes the instrument a turn-key device for today's state-of- the-art optical testing.

  5. Collimator changer for scintillation camera

    International Nuclear Information System (INIS)

    Jupa, E.C.; Meeder, R.L.; Richter, E.K.

    1976-01-01

    A collimator changing assembly mounted on the support structure of a scintillation camera is described. A vertical support column positioned proximate the detector support column with a plurality of support arms mounted thereon in a rotatable cantilevered manner at separate vertical positions. Each support arm is adapted to carry one of the plurality of collimators which are interchangeably mountable on the underside of the detector and to transport the collimator between a store position remote from the detector and a change position underneath said detector

  6. Robot Tracer with Visual Camera

    Science.gov (United States)

    Jabbar Lubis, Abdul; Dwi Lestari, Yuyun; Dafitri, Haida; Azanuddin

    2017-12-01

    Robot is a versatile tool that can function replace human work function. The robot is a device that can be reprogrammed according to user needs. The use of wireless networks for remote monitoring needs can be utilized to build a robot that can be monitored movement and can be monitored using blueprints and he can track the path chosen robot. This process is sent using a wireless network. For visual robot using high resolution cameras to facilitate the operator to control the robot and see the surrounding circumstances.

  7. Radioluminescence dating: the IR emission of feldspar

    International Nuclear Information System (INIS)

    Schilles, Thomas.; Habermann, Jan

    2000-01-01

    A new luminescence reader for radioluminescence (RL) measurements is presented. The system allows detection of RL emissions in the near infrared region (IR). Basic bleaching properties of the IR-RL emission of feldspars are investigated. Sunlight-bleaching experiments as a test for sensitivity changes are presented. IR-bleaching experiments were carried out to obtain information about the underlying physical processes of the IR-RL emission

  8. Prevalence of Staphylococcal Enterotoxins in Ready-to-Eat Foods Sold in Istanbul.

    Science.gov (United States)

    Ulusoy, Beyza H; Çakmak Sancar, Burcu; Öztürk, Muhsin

    2017-10-01

    The aim of this study was to investigate the prevalence of staphylococcal enterotoxins (SEs) in ready-to-eat (RTE) foods sold in Istanbul, Turkey. A total of 5,241 samples were randomly collected from various caterers, hotels, and restaurants from 2014 to 2016. The samples were classified into four groups: (i) various cooked RTE meat and vegetable meals, (ii) various RTE salads, charcuterie, and cold appetizers, (iii) various cooked RTE bakery products (pasta, pastries, pizza, pita, ravioli, etc.), and (iv) any cooked RTE sweets and desserts (pudding, custard, cream, ashura, etc.). The samples were examined for the presence of SEs by 3M Tecra Staph Enterotoxin Visual Immunoassay method, which is a manual enzyme-linked immunosorbent assay method. Among all samples, only 1 (0.019%) RTE meal (vegetable meal with meat) was found to be contaminated with SEs, a good result in terms of staphylococcal food poisoning risk and public health.

  9. [Survey of the presence of Listeria monocytogenes in meat products sold in retail].

    Science.gov (United States)

    Langiano, E; Lanni, L; Atrei, P; De Vito, E

    2007-01-01

    The present study evaluates the presence of Listeria spp and particularly of L. monocytogenes in bovine, pork and poultry meats sold by retail in supermarkets and butchers in the city of Cassino. The sensibility to the antibiotics mostly used in the veterinary practice has been tested on the isolated strains. The different species of Listeria have shown a considerable variation of isolation based on the meat's typology and on the different store's provenance. Moreover our results show greater degree of contamination than the data currently available the Italian literature. In our study poultry meat is the most contaminated one. We can assert that omissions and poor caring errors in the manipulation and conservation of meat expose the customer to an even higher risk of infection.

  10. Potential effects of the next 100 billion hamburgers sold by McDonald's.

    Science.gov (United States)

    Spencer, Elsa H; Frank, Erica; McIntosh, Nichole F

    2005-05-01

    McDonald's has sold >100 billion beef-based hamburgers worldwide with a potentially considerable health impact. This paper explores whether there would be any advantages if the next 100 billion burgers were instead plant-based burgers. Nutrient composition of the beef hamburger patty and the McVeggie burger patty were obtained from the McDonald's website; sales data were obtained from the McDonald's customer service. Consuming 100 billion McDonald's beef burgers versus the same company's McVeggie burgers would provide, approximately, on average, an additional 550 million pounds of saturated fat and 1.2 billion total pounds of fat, as well as 1 billion fewer pounds of fiber, 660 million fewer pounds of protein, and no difference in calories. These data suggest that the McDonald's new McVeggie burger represents a less harmful fast-food choice than the beef burger.

  11. Isolation of pathogenic Escherichia coli from buffalo meat sold in Parbhani city, Maharashtra, India

    Directory of Open Access Journals (Sweden)

    M. S. Vaidya

    2013-10-01

    Full Text Available Aim: Isolation, characterization, in-vitro pathogenicity and antibiogram study of E.coli from buffalo meat sold in Parbhani city. Materials and Methods: Meat samples were collected from buffalo immediately after slaughter. Isolation, identification and enumeration of E. coli were done by following standard methods and protocols. Hemolysin test and Congo red binding assay were used to study in-vitro pathogenicity of E. coli isolates. Disc diffusion method was used to study antibiogram of pathogenic E. coli isolates. Results: A total of 250 buffalo meat samples were collected and processed. A total of 22 (8.80 percent E. coli isolates were isolated with average differential count of 1.231 ± 0.136 log cfu/g on EMB agar. All the E. coli isolates were confirmed by 10 Grams staining, biochemical reactions and sugar fermentation and motility tests. A total of 9 (3.6 percent E. coli isolates were found to be pathogenic by in-vitro pathogenicity testing. Antibiogram studies of pathogenic E. coli isolates showed that all 9 isolates were sensitive to gentamycin (20 ± 1.49 mm while 7 isolate showed resistance to enrofloxacin (18.22 ± 3.58 mm and tetracycline (11.44 ± 2.04 mm. Conclusion: Buffalo meat sold in Parbhani city is an important source of E. coli infection to human population. A total of 9 pathogenic E. coli were isolated from buffalo meat immediately after slaughter. All isolates were characterized and confirmed pathogenic by in-vitro pathogenicity tests. Antibiogram studies of all isolates revealed sensitivity to gentamicin and resistance to tetracycline and enrofloxacin. [Vet World 2013; 6(5.000: 277-279

  12. Energy efficiency versus gains in consumer amenities—An example from new cars sold in Sweden

    International Nuclear Information System (INIS)

    Sprei, Frances; Karlsson, Sten

    2013-01-01

    Technological developments that increase energy efficiency result in net energy-saving benefits, provided the increased efficiency is not offset by enhanced consumer amenities. This paper analyzes the technology development/consumer amenities trade-off for new cars sold in Sweden between 1975 and 2010. We combine lessons learned from the policies in place and interviews with key actors in the car-purchasing process with statistical modeling of trends in vehicle attributes and technological development. Until 2007, consumer amenities were continuously enhanced, offsetting most of the efficiency gains of technological development; there was no strong policy push toward energy efficiency. In recent years, two major shifts have occurred. First, there has been a shift in the majority of new cars sold, from gasoline-powered engines to diesel engines. Flex-fuel vehicles have also contributed to a decline in the sales-share of pure gasoline engines. The observed shift of fuels, especially to flex-fuels, has been encouraged by policies. Second, after 2007 there have been major technological improvements, while attributes related to consumer amenities have remained flat, reversing the trends so that 77% of the technological development resulted in actual reduction of specific fuel consumption. EU targets, tax reforms, and consumer awareness have contributed to this trend change. - Highlights: ► Trade-offs between consumer amenities and fuel consumption of new cars in Sweden. ► Methods: Statistical modeling, policy analysis and interviews. ► Until 2007 a majority of technological development is offset by consumer amenities. ► After 2005 a shift from gasoline to diesel and flex-fuels takes place. ► Policy change and environmental awareness result in a reversion of trends.

  13. The cloud monitor by an infrared camera at the Telescope Array experiment

    International Nuclear Information System (INIS)

    Shibata, F.

    2011-01-01

    The mesurement of the extensive air shower using the fluorescence detectors (FDs) is affected by the condition of the atmosphere. In particular, FD aperture is limited by cloudiness. If cloud exists on the light path from extensive air shower to FDs, fluorescence photons will be absorbed drastically. Therefore cloudiness of FD's field of view (FOV) is one of important quality cut condition in FD analysis. In the Telescope Array (TA), an infrared (IR) camera with 320x236 pixels and a filed of view of 25.8 deg. x19.5 deg. has been installed at an observation site for cloud monitoring during FD observations. This IR camera measures temperature of the sky every 30 min during FD observation. IR camera is mounted on steering table, which can be changed in elevation and azimuthal direction. Clouds can be seen at a higher temperature than areas of cloudless sky from these temperature maps. In this paper, we discuss the quality of the cloud monitoring data, the analysis method, and current quality cut condition of cloudiness in FD analysis.

  14. Isolated Gramicidin Peptides Probed by IR Spectroscopy

    NARCIS (Netherlands)

    Rijs, A. M.; Kabelac, M.; Abo-Riziq, A.; Hobza, P.; de Vries, M. S.

    2011-01-01

    We report double-resonant IR/UV ion-dip spectroscopy of neutral gramicidin peptides in the gas phase. The IR spectra of gramicidin A and C, recorded in both the 1000 cm(-1) to 1800 cm(-1) and the 2700 to 3750 cm(-1) region, allow structural analysis. By studying this broad IR range, various local

  15. Using DSLR cameras in digital holography

    Science.gov (United States)

    Hincapié-Zuluaga, Diego; Herrera-Ramírez, Jorge; García-Sucerquia, Jorge

    2017-08-01

    In Digital Holography (DH), the size of the bidimensional image sensor to record the digital hologram, plays a key role on the performance of this imaging technique; the larger the size of the camera sensor, the better the quality of the final reconstructed image. Scientific cameras with large formats are offered in the market, but their cost and availability limit their use as a first option when implementing DH. Nowadays, DSLR cameras provide an easy-access alternative that is worthwhile to be explored. The DSLR cameras are a wide, commercial, and available option that in comparison with traditional scientific cameras, offer a much lower cost per effective pixel over a large sensing area. However, in the DSLR cameras, with their RGB pixel distribution, the sampling of information is different to the sampling in monochrome cameras usually employed in DH. This fact has implications in their performance. In this work, we discuss why DSLR cameras are not extensively used for DH, taking into account the problem reported by different authors of object replication. Simulations of DH using monochromatic and DSLR cameras are presented and a theoretical deduction for the replication problem using the Fourier theory is also shown. Experimental results of DH implementation using a DSLR camera show the replication problem.

  16. Human tracking over camera networks: a review

    Science.gov (United States)

    Hou, Li; Wan, Wanggen; Hwang, Jenq-Neng; Muhammad, Rizwan; Yang, Mingyang; Han, Kang

    2017-12-01

    In recent years, automated human tracking over camera networks is getting essential for video surveillance. The tasks of tracking human over camera networks are not only inherently challenging due to changing human appearance, but also have enormous potentials for a wide range of practical applications, ranging from security surveillance to retail and health care. This review paper surveys the most widely used techniques and recent advances for human tracking over camera networks. Two important functional modules for the human tracking over camera networks are addressed, including human tracking within a camera and human tracking across non-overlapping cameras. The core techniques of human tracking within a camera are discussed based on two aspects, i.e., generative trackers and discriminative trackers. The core techniques of human tracking across non-overlapping cameras are then discussed based on the aspects of human re-identification, camera-link model-based tracking and graph model-based tracking. Our survey aims to address existing problems, challenges, and future research directions based on the analyses of the current progress made toward human tracking techniques over camera networks.

  17. Image compensation for camera and lighting variability

    Science.gov (United States)

    Daley, Wayne D.; Britton, Douglas F.

    1996-12-01

    With the current trend of integrating machine vision systems in industrial manufacturing and inspection applications comes the issue of camera and illumination stabilization. Unless each application is built around a particular camera and highly controlled lighting environment, the interchangeability of cameras of fluctuations in lighting become a problem as each camera usually has a different response. An empirical approach is proposed where color tile data is acquired using the camera of interest, and a mapping is developed to some predetermined reference image using neural networks. A similar analytical approach based on a rough analysis of the imaging systems is also considered for deriving a mapping between cameras. Once a mapping has been determined, all data from one camera is mapped to correspond to the images of the other prior to performing any processing on the data. Instead of writing separate image processing algorithms for the particular image data being received, the image data is adjusted based on each particular camera and lighting situation. All that is required when swapping cameras is the new mapping for the camera being inserted. The image processing algorithms can remain the same as the input data has been adjusted appropriately. The results of utilizing this technique are presented for an inspection application.

  18. Optimising camera traps for monitoring small mammals.

    Directory of Open Access Journals (Sweden)

    Alistair S Glen

    Full Text Available Practical techniques are required to monitor invasive animals, which are often cryptic and occur at low density. Camera traps have potential for this purpose, but may have problems detecting and identifying small species. A further challenge is how to standardise the size of each camera's field of view so capture rates are comparable between different places and times. We investigated the optimal specifications for a low-cost camera trap for small mammals. The factors tested were 1 trigger speed, 2 passive infrared vs. microwave sensor, 3 white vs. infrared flash, and 4 still photographs vs. video. We also tested a new approach to standardise each camera's field of view. We compared the success rates of four camera trap designs in detecting and taking recognisable photographs of captive stoats (Mustelaerminea, feral cats (Felis catus and hedgehogs (Erinaceuseuropaeus. Trigger speeds of 0.2-2.1 s captured photographs of all three target species unless the animal was running at high speed. The camera with a microwave sensor was prone to false triggers, and often failed to trigger when an animal moved in front of it. A white flash produced photographs that were more readily identified to species than those obtained under infrared light. However, a white flash may be more likely to frighten target animals, potentially affecting detection probabilities. Video footage achieved similar success rates to still cameras but required more processing time and computer memory. Placing two camera traps side by side achieved a higher success rate than using a single camera. Camera traps show considerable promise for monitoring invasive mammal control operations. Further research should address how best to standardise the size of each camera's field of view, maximise the probability that an animal encountering a camera trap will be detected, and eliminate visible or audible cues emitted by camera traps.

  19. General Astrophysics with the HabEx Workhorse Camera

    Science.gov (United States)

    Stern, Daniel; Clarke, John; Gaudi, B. Scott; Kiessling, Alina; Krause, Oliver; Martin, Stefan; Scowen, Paul; Somerville, Rachel; HabEx STDT

    2018-01-01

    The Habitable Exoplanet Imaging Mission (HabEx) concept has been designed to enable an extensive suite of science, broadly put under the rubric of General Astrophysics, in addition to its exoplanet direct imaging science. General astrophysics directly addresses multiple NASA programmatic branches, and HabEx will enable investigations ranging from cosmology, to galaxy evolution, to stellar population studies, to exoplanet transit spectroscopy, to Solar System studies. This poster briefly describes one of the two primary HabEx General Astrophysics instruments, the HabEx Workhorse Camera (HWC). HWC will be a dual-detector UV-to-near-IR imager and multi-object grism spectrometer with a microshutter array and a moderate (3' x 3') field-of-view. We detail some of the key science we expect HWC to undertake, emphasizing unique capabilities enabled by a large-aperture, highly stable space-borne platform at these wavelengths.

  20. The Infrared Camera for RATIR, a Rapid Response GRB Followup Instrument

    Science.gov (United States)

    Rapchun, David A.; Alardin, W.; Bigelow, B. C.; Bloom, J.; Butler, N.; Farah, A.; Fox, O. D.; Gehrels, N.; Gonzalez, J.; Klein, C.; Kutyrev, A. S.; Lotkin, G.; Morisset, C.; Moseley, S. H.; Richer, M.; Robinson, F. D.; Samuel, M. V.; Sparr, L. M.; Tucker, C.; Watson, A.

    2011-01-01

    RATIR (Reionization and Transients Infrared instrument) will be a hybrid optical/near IR imager that will utilize the "J-band dropout" to rapidly identify very high redshift (VHR) gamma-ray bursts (GRBs) from a sample of all observable Swift bursts. Our group at GSFC is developing the instrument in collaboration with UC Berkeley (UCB) and University of Mexico (UNAM). RATIR has both a visible and IR camera, which give it access to 8 bands spanning visible and IR wavelengths. The instrument implements a combination of filters and dichroics to provide the capability of performing photometry in 4 bands simultaneously. The GSFC group leads the design and construction of the instrument's IR camera, equipped with two HgCdTe 2k x 2k Teledyne detectors. The cryostat housing these detectors is cooled by a mechanical cryo-compressor, which allows uninterrupted operation on the telescope. The host 1.5-m telescope, located at the UNAM San Pedro Martir Observatory, Mexico, has recently undergone robotization, allowing for fully automated, continuous operation. After commissioning in the spring of 2011, RATIR will dedicate its time to obtaining prompt follow-up observations of GRBs and identifying VHR GRBs, thereby providing a valuable tool for studying the epoch of reionization.

  1. Simultaneous monitoring of ice accretion and thermography of an airfoil: an IR imaging methodology

    International Nuclear Information System (INIS)

    Mohseni, M; Frioult, M; Amirfazli, A

    2012-01-01

    A novel image analysis methodology based on infrared (IR) imaging was developed for simultaneous monitoring of ice accretion and thermography of airfoils. In this study, an IR camera was calibrated and used to measure the surface temperature of the energized airfoils, and monitor the ice accretion and growth pattern on the airfoils’ surfaces. The methodology comprises the automatic processing of a series of IR video frames with the purpose of detecting ice pattern evolution during the icing test period. A specially developed MATLAB code was used to detect the iced areas in the IR images, and simultaneously monitor surface temperature evolution of the airfoil during an icing test. Knowing the correlation between the icing pattern and surface temperature changes during an icing test is essential for energy efficient design of thermal icing mitigation systems. Processed IR images were also used to determine the ice accumulation rate on the airfoil's surface in a given icing test. The proposed methodology has been demonstrated to work successfully, since the optical images taken at the end of icing tests from the airfoils’ surfaces compared well with the processed IR images detecting the ice grown outward from the airfoils’ leading edge area. (paper)

  2. Photogrammetric Applications of Immersive Video Cameras

    OpenAIRE

    Kwiatek, K.; Tokarczyk, R.

    2014-01-01

    The paper investigates immersive videography and its application in close-range photogrammetry. Immersive video involves the capture of a live-action scene that presents a 360° field of view. It is recorded simultaneously by multiple cameras or microlenses, where the principal point of each camera is offset from the rotating axis of the device. This issue causes problems when stitching together individual frames of video separated from particular cameras, however there are ways to ov...

  3. Movement-based Interaction in Camera Spaces

    DEFF Research Database (Denmark)

    Eriksson, Eva; Riisgaard Hansen, Thomas; Lykke-Olesen, Andreas

    2006-01-01

    In this paper we present three concepts that address movement-based interaction using camera tracking. Based on our work with several movement-based projects we present four selected applications, and use these applications to leverage our discussion, and to describe our three main concepts space......, relations, and feedback. We see these as central for describing and analysing movement-based systems using camera tracking and we show how these three concepts can be used to analyse other camera tracking applications....

  4. Performance analysis for gait in camera networks

    OpenAIRE

    Michela Goffredo; Imed Bouchrika; John Carter; Mark Nixon

    2008-01-01

    This paper deploys gait analysis for subject identification in multi-camera surveillance scenarios. We present a new method for viewpoint independent markerless gait analysis that does not require camera calibration and works with a wide range of directions of walking. These properties make the proposed method particularly suitable for gait identification in real surveillance scenarios where people and their behaviour need to be tracked across a set of cameras. Tests on 300 synthetic and real...

  5. Development of plenoptic infrared camera using low dimensional material based photodetectors

    Science.gov (United States)

    Chen, Liangliang

    Infrared (IR) sensor has extended imaging from submicron visible spectrum to tens of microns wavelength, which has been widely used for military and civilian application. The conventional bulk semiconductor materials based IR cameras suffer from low frame rate, low resolution, temperature dependent and highly cost, while the unusual Carbon Nanotube (CNT), low dimensional material based nanotechnology has been made much progress in research and industry. The unique properties of CNT lead to investigate CNT based IR photodetectors and imaging system, resolving the sensitivity, speed and cooling difficulties in state of the art IR imagings. The reliability and stability is critical to the transition from nano science to nano engineering especially for infrared sensing. It is not only for the fundamental understanding of CNT photoresponse induced processes, but also for the development of a novel infrared sensitive material with unique optical and electrical features. In the proposed research, the sandwich-structured sensor was fabricated within two polymer layers. The substrate polyimide provided sensor with isolation to background noise, and top parylene packing blocked humid environmental factors. At the same time, the fabrication process was optimized by real time electrical detection dielectrophoresis and multiple annealing to improve fabrication yield and sensor performance. The nanoscale infrared photodetector was characterized by digital microscopy and precise linear stage in order for fully understanding it. Besides, the low noise, high gain readout system was designed together with CNT photodetector to make the nano sensor IR camera available. To explore more of infrared light, we employ compressive sensing algorithm into light field sampling, 3-D camera and compressive video sensing. The redundant of whole light field, including angular images for light field, binocular images for 3-D camera and temporal information of video streams, are extracted and

  6. Sodium, Sugar and Fat Content of Complimentary Infant and Toddler Foods Sold in the United States, 2015

    Science.gov (United States)

    In 2012, 72% of commercial toddler meals contained >210 mg/serving of sodium and >70% of infant and toddler snacks, desserts, and juice drinks contained one or more added sugars. The objective is to update the sodium, sugar and fat values of commercial infant and toddler foods sold in the U.S. in 20...

  7. SHPPS 2006: School Health Policies and Programs Study--Foods and Beverages Sold Outside of the School Meals Programs

    Science.gov (United States)

    Centers for Disease Control and Prevention, 2007

    2007-01-01

    The School health Policies and Programs Study (SHPPS) is a national survey periodically conducted to assess school health policies and programs at the state, district, school, and classroom levels. This brief reports study results in the area of foods and beverages sold outside of the school meals program. (Contains 3 tables, 1 figure, and 2…

  8. Explosive Transient Camera (ETC) Program

    Science.gov (United States)

    Ricker, George

    1991-01-01

    Since the inception of the ETC program, a wide range of new technologies was developed to support this astronomical instrument. The prototype unit was installed at ETC Site 1. The first partially automated observations were made and some major renovations were later added to the ETC hardware. The ETC was outfitted with new thermoelectrically-cooled CCD cameras and a sophisticated vacuum manifold, which, together, made the ETC a much more reliable unit than the prototype. The ETC instrumentation and building were placed under full computer control, allowing the ETC to operate as an automated, autonomous instrument with virtually no human intervention necessary. The first fully-automated operation of the ETC was performed, during which the ETC monitored the error region of the repeating soft gamma-ray burster SGR 1806-21.

  9. Camera processing with chromatic aberration.

    Science.gov (United States)

    Korneliussen, Jan Tore; Hirakawa, Keigo

    2014-10-01

    Since the refractive index of materials commonly used for lens depends on the wavelengths of light, practical camera optics fail to converge light to a single point on an image plane. Known as chromatic aberration, this phenomenon distorts image details by introducing magnification error, defocus blur, and color fringes. Though achromatic and apochromatic lens designs reduce chromatic aberration to a degree, they are complex and expensive and they do not offer a perfect correction. In this paper, we propose a new postcapture processing scheme designed to overcome these problems computationally. Specifically, the proposed solution is comprised of chromatic aberration-tolerant demosaicking algorithm and post-demosaicking chromatic aberration correction. Experiments with simulated and real sensor data verify that the chromatic aberration is effectively corrected.

  10. Approximations to camera sensor noise

    Science.gov (United States)

    Jin, Xiaodan; Hirakawa, Keigo

    2013-02-01

    Noise is present in all image sensor data. Poisson distribution is said to model the stochastic nature of the photon arrival process, while it is common to approximate readout/thermal noise by additive white Gaussian noise (AWGN). Other sources of signal-dependent noise such as Fano and quantization also contribute to the overall noise profile. Question remains, however, about how best to model the combined sensor noise. Though additive Gaussian noise with signal-dependent noise variance (SD-AWGN) and Poisson corruption are two widely used models to approximate the actual sensor noise distribution, the justification given to these types of models are based on limited evidence. The goal of this paper is to provide a more comprehensive characterization of random noise. We concluded by presenting concrete evidence that Poisson model is a better approximation to real camera model than SD-AWGN. We suggest further modification to Poisson that may improve the noise model.

  11. Comparative evaluation of consumer grade cameras and mobile phone cameras for close range photogrammetry

    Science.gov (United States)

    Chikatsu, Hirofumi; Takahashi, Yoji

    2009-08-01

    The authors have been concentrating on developing convenient 3D measurement methods using consumer grade digital cameras, and it was concluded that consumer grade digital cameras are expected to become a useful photogrammetric device for the various close range application fields. On the other hand, mobile phone cameras which have 10 mega pixels were appeared on the market in Japan. In these circumstances, we are faced with alternative epoch-making problem whether mobile phone cameras are able to take the place of consumer grade digital cameras in close range photogrammetric applications. In order to evaluate potentials of mobile phone cameras in close range photogrammetry, comparative evaluation between mobile phone cameras and consumer grade digital cameras are investigated in this paper with respect to lens distortion, reliability, stability and robustness. The calibration tests for 16 mobile phone cameras and 50 consumer grade digital cameras were conducted indoors using test target. Furthermore, practability of mobile phone camera for close range photogrammetry was evaluated outdoors. This paper presents that mobile phone cameras have ability to take the place of consumer grade digital cameras, and develop the market in digital photogrammetric fields.

  12. Decision about buying a gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    A large part of the referral to a nuclear medicine department is usually for imaging studies. Sooner or later, the nuclear medicine specialist will be called upon to make a decision about when and what type of gamma camera to buy. There is no longer an option of choosing between a rectilinear scanner and a gamma camera as the former is virtually out of the market. The decision that one has to make is when to invest in a gamma camera, and then on what basis to select the gamma camera 1 tab., 1 fig

  13. Object tracking using multiple camera video streams

    Science.gov (United States)

    Mehrubeoglu, Mehrube; Rojas, Diego; McLauchlan, Lifford

    2010-05-01

    Two synchronized cameras are utilized to obtain independent video streams to detect moving objects from two different viewing angles. The video frames are directly correlated in time. Moving objects in image frames from the two cameras are identified and tagged for tracking. One advantage of such a system involves overcoming effects of occlusions that could result in an object in partial or full view in one camera, when the same object is fully visible in another camera. Object registration is achieved by determining the location of common features in the moving object across simultaneous frames. Perspective differences are adjusted. Combining information from images from multiple cameras increases robustness of the tracking process. Motion tracking is achieved by determining anomalies caused by the objects' movement across frames in time in each and the combined video information. The path of each object is determined heuristically. Accuracy of detection is dependent on the speed of the object as well as variations in direction of motion. Fast cameras increase accuracy but limit the speed and complexity of the algorithm. Such an imaging system has applications in traffic analysis, surveillance and security, as well as object modeling from multi-view images. The system can easily be expanded by increasing the number of cameras such that there is an overlap between the scenes from at least two cameras in proximity. An object can then be tracked long distances or across multiple cameras continuously, applicable, for example, in wireless sensor networks for surveillance or navigation.

  14. Scintillation camera for high activity sources

    International Nuclear Information System (INIS)

    Arseneau, R.E.

    1978-01-01

    The invention described relates to a scintillation camera used for clinical medical diagnosis. Advanced recognition of many unacceptable pulses allows the scintillation camera to discard such pulses at an early stage in processing. This frees the camera to process a greater number of pulses of interest within a given period of time. Temporary buffer storage allows the camera to accommodate pulses received at a rate in excess of its maximum rated capability due to statistical fluctuations in the level of radioactivity of the radiation source measured. (U.K.)

  15. Decision about buying a gamma camera

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    A large part of the referral to a nuclear medicine department is usually for imaging studies. Sooner or later, the nuclear medicine specialist will be called upon to make a decision about when and what type of gamma camera to buy. There is no longer an option of choosing between a rectilinear scanner and a gamma camera as the former is virtually out of the market. The decision that one has to make is when to invest in a gamma camera, and then on what basis to select the gamma camera

  16. Streak camera recording of interferometer fringes

    International Nuclear Information System (INIS)

    Parker, N.L.; Chau, H.H.

    1977-01-01

    The use of an electronic high-speed camera in the streaking mode to record interference fringe motion from a velocity interferometer is discussed. Advantages of this method over the photomultiplier tube-oscilloscope approach are delineated. Performance testing and data for the electronic streak camera are discussed. The velocity profile of a mylar flyer accelerated by an electrically exploded bridge, and the jump-off velocity of metal targets struck by these mylar flyers are measured in the camera tests. Advantages of the streak camera include portability, low cost, ease of operation and maintenance, simplified interferometer optics, and rapid data analysis

  17. The Quality of Selected Essential Medicines Sold in Accredited Drug Dispensing Outlets and Pharmacies in Tanzania.

    Directory of Open Access Journals (Sweden)

    Eliangiringa Kaale

    Full Text Available The purpose of this study was to investigate the quality of a select group of medicines sold in accredited drug dispensing outlets (ADDOs and pharmacies in different regions of Tanzania as part of an in-depth cross-sectional assessment of community access to medicines and community use of medicines.We collected 242 samples of amoxicillin trihydrate, artemether-lumefantrine (ALu, co-trimoxazole, ergometrine maleate, paracetamol, and quinine from selected ADDOs and pharmacies in Mbeya, Morogoro, Singida, and Tanga regions. The analysis included physical examination and testing with validated analytical techniques. Assays for eight of nine products were conducted using high-performance thin-layer chromatography (HPTLC. For ALu tablets, we used a two-tiered approach, where tier 1 was a semi-quantitative Global Pharma Health Fund-Minilab® method and tier 2 was high-performance liquid chromatography (HPLC as described in The International Pharmacopoeia's monograph for artemether-lumefantrine.The physical examination of samples revealed no defects in the solid and oral liquid dosage forms, but unusual discoloration in an injectable solution, ergometrine maleate. For ALu, the results showed that of 38 samples, 31 (81.6% passed tier 1 testing and 7 (18.4% gave inconclusive drug content results. The inconclusive ALu samples were submitted for tier 2 testing and all met the quality standards. The pass rate using the HPTLC and TLC/HPLC assays was 93.8%; the failures were the ergometrine maleate samples purchased from both ADDOs and pharmacies. The disintegration testing of the solid dosage forms was conducted in accordance with US Pharmacopeia monographs. Only two samples of paracetamol, 1.2% of the solid dosage forms, failed to comply to standards. The study revealed a high overall rate of 92.6% of samples that met the quality standards. Although the overall failure rate was 7.4%, it is important to note that this was largely limited to one product and

  18. The Quality of Selected Essential Medicines Sold in Accredited Drug Dispensing Outlets and Pharmacies in Tanzania.

    Science.gov (United States)

    Kaale, Eliangiringa; Manyanga, Vicky; Chambuso, Mhina; Liana, Jafary; Rutta, Edmund; Embrey, Martha; Layloff, Thomas; Johnson, Keith

    2016-01-01

    The purpose of this study was to investigate the quality of a select group of medicines sold in accredited drug dispensing outlets (ADDOs) and pharmacies in different regions of Tanzania as part of an in-depth cross-sectional assessment of community access to medicines and community use of medicines. We collected 242 samples of amoxicillin trihydrate, artemether-lumefantrine (ALu), co-trimoxazole, ergometrine maleate, paracetamol, and quinine from selected ADDOs and pharmacies in Mbeya, Morogoro, Singida, and Tanga regions. The analysis included physical examination and testing with validated analytical techniques. Assays for eight of nine products were conducted using high-performance thin-layer chromatography (HPTLC). For ALu tablets, we used a two-tiered approach, where tier 1 was a semi-quantitative Global Pharma Health Fund-Minilab® method and tier 2 was high-performance liquid chromatography (HPLC) as described in The International Pharmacopoeia's monograph for artemether-lumefantrine. The physical examination of samples revealed no defects in the solid and oral liquid dosage forms, but unusual discoloration in an injectable solution, ergometrine maleate. For ALu, the results showed that of 38 samples, 31 (81.6%) passed tier 1 testing and 7 (18.4%) gave inconclusive drug content results. The inconclusive ALu samples were submitted for tier 2 testing and all met the quality standards. The pass rate using the HPTLC and TLC/HPLC assays was 93.8%; the failures were the ergometrine maleate samples purchased from both ADDOs and pharmacies. The disintegration testing of the solid dosage forms was conducted in accordance with US Pharmacopeia monographs. Only two samples of paracetamol, 1.2% of the solid dosage forms, failed to comply to standards. The study revealed a high overall rate of 92.6% of samples that met the quality standards. Although the overall failure rate was 7.4%, it is important to note that this was largely limited to one product and likely due to

  19. 7 CFR 205.309 - Agricultural products in other than packaged form at the point of retail sale that are sold...

    Science.gov (United States)

    2010-01-01

    ... the point of retail sale that are sold, labeled, or represented as âmade with organic (specified..., Labeling, and Market Information § 205.309 Agricultural products in other than packaged form at the point of retail sale that are sold, labeled, or represented as “made with organic (specified ingredients or...

  20. Innovations in IR projector arrays

    Science.gov (United States)

    Cole, Barry E.; Higashi, B.; Ridley, Jeff A.; Holmen, J.; Newstrom, K.; Zins, C.; Nguyen, K.; Weeres, Steven R.; Johnson, Burgess R.; Stockbridge, Robert G.; Murrer, Robert Lee; Olson, Eric M.; Bergin, Thomas P.; Kircher, James R.; Flynn, David S.

    2000-07-01

    In the past year, Honeywell has developed a 512 X 512 snapshot scene projector containing pixels with very high radiance efficiency. The array can operate in both snapshot and raster mode. The array pixels have near black body characteristics, high radiance outputs, broad band performance, and high speed. IR measurements and performance of these pixels will be described. In addition, a vacuum probe station that makes it possible to select the best die for packaging and delivery based on wafer level radiance screening, has been developed and is in operation. This system, as well as other improvements, will be described. Finally, a review of the status of the present projectors and plans for future arrays is included.

  1. Improving Situational Awareness in camera surveillance by combining top-view maps with camera images

    NARCIS (Netherlands)

    Kooi, F.L.; Zeeders, R.

    2009-01-01

    The goal of the experiment described is to improve today's camera surveillance in public spaces. Three designs with the camera images combined on a top-view map were compared to each other and to the current situation in camera surveillance. The goal was to test which design makes spatial

  2. Automatic inference of geometric camera parameters and intercamera topology in uncalibrated disjoint surveillance cameras

    NARCIS (Netherlands)

    Hollander, R.J.M. den; Bouma, H.; Baan, J.; Eendebak, P.T.; Rest, J.H.C. van

    2015-01-01

    Person tracking across non-overlapping cameras and other types of video analytics benefit from spatial calibration information that allows an estimation of the distance between cameras and a relation between pixel coordinates and world coordinates within a camera. In a large environment with many

  3. Determination of contamination pathways of phthalates in food products sold on the Belgian market.

    Science.gov (United States)

    Van Holderbeke, Mirja; Geerts, Lieve; Vanermen, Guido; Servaes, Kelly; Sioen, Isabelle; De Henauw, Stefaan; Fierens, Tine

    2014-10-01

    As numerous studies have indicated that food ingestion is the most important exposure pathway to several phthalates, this study aimed to determine possible contamination pathways of phthalates in food products sold on the Belgian market. To do this, concentrations of eight phthalates (dimethyl phthalate (DMP), diethyl phthalate (DEP), diisobutyl phthalate (DiBP), di-n-butyl phthalate (DnBP), benzylbutyl phthalate (BBP), dicyclohexyl phthalate (DCHP), di(2-ethylhexyl) phthalate (DEHP) and di-n-octyl phthalate (DnOP)) were determined in 591 foods and 30 packaging materials. In general, the four most prominent phthalates in Belgian food products were DEHP, DiBP, DnBP and BBP. Special attention was given to the origin of these phthalates in bread, since high phthalate concentrations (especially DEHP) were determined in this frequently consumed food product. Phthalates seemed to occur in Belgian bread samples due to the use of contaminated ingredients (i.e. use of contaminated flour) as well as due to migration from phthalate containing contact materials used during production (e.g. coated baking trays). Also the results of the conducted concentration profiles of apple, bread, salami and two cheese types revealed the important role of processing - and not packaging - on phthalate contents in foods. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Determination of Ethyl Carbamate in Alcoholic Beverages and Fermented Foods Sold in Korea.

    Science.gov (United States)

    Ryu, Dayeon; Choi, Bogyoung; Kim, Eunjoo; Park, Seri; Paeng, Hwijin; Kim, Cho-Il; Lee, Jee-Yeon; Yoon, Hae Jung; Koh, Eunmi

    2015-09-01

    Ethyl carbamate (EC) classified as a probable human carcinogen (Group 2A) is naturally formed in alcoholic beverages and fermented foods during fermentation process and/or during storage. The objective of this study was to analyze EC in 34 food items including 14 alcoholic beverages and 20 fermented foods sold in Korea. Each food was collected from 18 supermarkets in 9 metropolitan cities in Korea, and then made into composite. According to food composition and alcohol content, samples were divided into four matrices such as apple juice, milk, Soju (liquor containing about 20% alcohol), and rice porridge. The maximum EC value of 151.06 µg/kg was found in Maesilju (liquor made from Maesil and Soju). Whisky and Bokbunjaju (Korean black raspberry wine) contained 9.90 µg/kg and 6.30 µg/kg, respectively. EC was not detected in other alcoholic beverages. Of 20 fermented foods, Japanese-style soy sauce had highest level of 15.59 µg/kg and traditional one contained 4.18 µg/kg. Soybean paste had 1.18 µg/kg, however, EC was not found in other fermented foods.

  5. Are products sold in university vending machines nutritionally poor? A food environment audit.

    Science.gov (United States)

    Grech, Amanda; Hebden, Lana; Roy, Rajshri; Allman-Farinelli, Margaret

    2017-04-01

    (i) To audit the nutritional composition, promotion and cost of products available from vending machines available to young adults; and (ii) to examine the relationship between product availability and sales. A cross-sectional analysis of snacks and beverages available and purchased at a large urban university was conducted between March and September 2014. Sales were electronically tracked for nine months. A total of 61 vending machines were identified; 95% (n = 864) of the available snacks and 49% of beverages (n = 455) were less-healthy items. The mean (SD) nutrient value of snacks sold was: energy 1173 kJ (437.5), saturated fat 5.36 g (3.6), sodium 251 mg (219), fibre 1.56 g (1.29) and energy density 20.16 kJ/g (2.34) per portion vended. There was a strong correlation between the availability of food and beverages and purchases (R 2 = 0.98, P Vending machines market and sell less-healthy food and beverages to university students. Efforts to improve the nutritional quality are indicated and afford an opportunity to improve the diet quality of young adults, a group at risk of obesity. © 2016 Dietitians Association of Australia.

  6. Strong increase in total delta-THC in cannabis preparations sold in Dutch coffee shops.

    Science.gov (United States)

    Pijlman, F T A; Rigter, S M; Hoek, J; Goldschmidt, H M J; Niesink, R J M

    2005-06-01

    The total concentration of THC has been monitored in cannabis preparations sold in Dutch coffee shops since 1999. This annual monitoring was issued by the Ministry of Health after reports of increased potency. The level of the main psychoactive compound, Delta9-tetrahydrocannabinol (THC), is measured in marijuana and hashish. A comparison is made between imported and Dutch preparations, and between seasons. Samples of cannabis preparations from randomly selected coffee shops were analyzed using gas chromatography (GC-FID) for THC, CBD and CBN. In 2004, the average THC level of Dutch home-grown marijuana (Nederwiet) (20.4% THC) was significantly higher than that of imported marijuana (7.0% THC). Hashish derived from Dutch marijuana (Nederhasj) contained 39.3% THC in 2004, compared with 18.2% THC in imported hashish. The average THC percentage of Dutch marijuana, Dutch hashish and imported hashish was significantly higher than in previous years. It nearly doubled over 5 years. During this period, the THC percentage in imported marijuana remained unchanged. A higher price had to be paid for cannabis with higher levels of THC. Whether the increase in THC levels causes increased health risks for users can only be concluded when more data are available on adjusted patterns of use, abuse liability, bioavailability and levels of THC in the brain.

  7. Microbioligical Hazard Contamination in Fermented Vegetables Sold in Local Markets in Cambodia.

    Science.gov (United States)

    Chrun, Rithy; Hosotani, Yukie; Kawasaki, Susumu; Inatsu, Yasuhiro

    2017-01-01

     Fermented vegetables are common part of Cambodian diet. The food safety status for these foods has not been investigated. This study was conducted to evaluate the microbiological hazards that contaminated fermented vegetables. A total of 68 samples of fermented vegetables were purchased randomly from five wet markets in Phnom Penh. The conventional culture methods for microbiological analysis were used. Coliform bacteria (Escherichia coli, Cronobactersakazakii, and Enterobacter spp.), opportunistic non-Entrobacteriaceae, Enterococcus spp., Staphylococcus spp., and Listeria spp. were found in these fermented foods. The highest contamination rate of Enterococcus spp. was 34% of total fermented vegetable samples, followed by Bacillus spp. coliform bacteria and E. coli (31%, 24% and 10%, respectively). The potential foodborne pathogen, C. sakazakii, was identified in one sample. Fermented mixed vegetables showed higher contamination rate of coliform bacteria (50%) than fermented single-type vegetables (13%). The results showed that fermented vegetables sold in wet market are poor in hygiene. The stage in the processing chain where contamination occurred should be identified and basic sanitary practice should be enforced to improve the food safety of fermented vegetables in Cambodia.

  8. Microbial quality of some vegetables sold in ED DueimTwon, Sudan.

    Science.gov (United States)

    Goja, Arafat Mohammed; Mahmoud, Mohamed Salih Osman

    2013-06-15

    This study was probably the first research carried out to investigate the microbiological quality of some vegetables sold in ED DueimTwon, Sudan. Four species of vegetables were used, Arugula (Eruca sativa), Mloukhia (Corchorus olitorius), Tomato (Lycopersicon esculentum) and Green pepper (Capsicum annuum). The samples were collected and examined according to standardized methods for total viable bacteria, coliforms and fecal coliform count. The average of total viable count ranged from 1.2 x 105-5.6 x 105 CFU mL(-1) for Arugula; 2.1 x 105-2.8 x 107 CFU mL(-1) for Mloukhia; 3.4 x 105-4.8 x 105 for Tomato and 2.3 x 105-8.0 x 106 CFU mL(-1) for Green pepper. However, the maximum level of total and fecal coliform were (93, 21); (28, 11); (75, 15) and (150, 20) MPN 100 mL(-1), respectively. Twelve bacteria belonging to five genera were isolated. Staphylococcus (33%) was the most predominant isolated followed by Enterobacteriaceae (25%), Bacillus (17%) and Streptococcus (17%). Micrococcus (8%) was the least dominant isolated. The results of microbial counts of these vegetable samples in this study indicate that, the agricultural practices, harvesting, hygiene, transporting and selling points are poor and therefore, the higher microbial load could be risked for public health.

  9. Evaluation of toxic heavy metals in ayurvedic syrups sold in local markets of hazara, pakistan

    International Nuclear Information System (INIS)

    Hajra, B.; Orakzai, S.; Hussain, F.; Farya, U.

    2015-01-01

    Herbal and Ayurvedic preparations, widely used in Pakistan and the developing world, present serious risk of heavy metal toxicity related to their medicinal content and prolonged use by patients. The objective of this study was to find out the concentration of heavy metals in Herbal and Ayurvedic liquid preparations commonly used for treatment of different diseases, from local markets of Hazara. Methods: The cross sectional survey of traditional herbal and Ayurvedic medicine shops included ten liquid preparations selected from local shops of Mansehra and Abbottabad after interviewing the shopkeepers; so as to select the most commonly sold preparations along with their indications. All samples were analysed on standard Atomic Absorption Spectroscopy for qualitative and quantitative study of toxic heavy metals (Mercury, Iron, Zinc, Lead, Manganese and Arsenic). Results: Toxic levels of Mercury were present in seven syrups, i.e., (Kashneeze, Akseer e Pachas, Tankar, Sharbat e folad, Urosinal, Akseer e Jigar and Amrat dhara) while Arsenic was present only in Urosinal. Iron, Zinc, Manganese and Lead were present in permissible limits in all syrups. Conclusion: Mercury and Arsenic are present in local Herbal and Ayurvedic liquid preparations far beyond the permissible limits as proposed by the International Regulatory Authorities for health drugs while the rest of metals, i.e., Zinc, Manganese, and Iron are within the therapeutic limits. (author)

  10. Detection of genetically modified maize in processed foods sold commercially in iran by qualitative PCR.

    Science.gov (United States)

    Rabiei, Maryam; Mehdizadeh, Mehrangiz; Rastegar, Hossein; Vahidi, Hossein; Alebouyeh, Mahmoud

    2013-01-01

    Detection of genetically modified organisms (GMOs) in food is an important issue for all the subjects involved in food control and customer's right. Due to the increasing number of GMOs imported to Iran during the past few years, it has become necessary to screen the products in order to determine the identity of the consumed daily foodstuffs. In this study, following the extraction of genomic DNA from processed foods sold commercially in Iran, qualitative PCR was performed to detect genetically modified maize. The recombinant DNA target sequences were detected with primers highly specific for each investigated transgene such as CaMV35s gene, Bt-11, MON810 and Bt-176 separately. Based on the gel electrophoresis results, Bt- 11 and MON810 events were detected in some maize samples, while, in none of them Bt- 176 modified gene was detected. For the first time, the results demonstrate the presence of genetically modified maize in Iranian food products, reinforcing the need for the development of labeling system and valid quantitative methods in routine analyses.

  11. Children sold for transplants: medical and legal aspects. Amnesty International--Danish Working Group for Children.

    Science.gov (United States)

    Fasting, U; Christensen, J; Glending, S

    1998-11-01

    Over the last few decades there has been a substantially higher percentage of successful organ transplants but also a significant imbalance between the demand for and the supply of organs, creating the basis for a highly profitable black market trade in human organs. Sometimes there are reports that children have been kidnapped, only to reappear later lacking one kidney, or that they simply disappear and are subsequently killed to have all their transplantable organs removed for profit. The European Union feels that there is a need for action and that it has a duty to act in this field, especially for ethical reasons. There is now established close co-operation between the various European transplant organizations. The legal protection of children with regard to organ transplantation is not specifically mentioned in the existing conventions because this issue was not foreseen at the time of their preparation. However, the issue is covered in a broader sense by more general provisions. There are endless rumours surrounding this area. Members of various organizations who travel in the suspected countries say that the trafficking in children who are sold for transplantation is well known, but it is too difficult and very dangerous to catch the people involved. We have to conclude that it has been impossible to prove or disprove the rumours, but they are consistent and we all, especially in the health care professions, have an obligation to be keenly aware of how and where organs are obtained.

  12. Optimal Overhaul-Replacement Policies for Repairable Machine Sold with Warranty

    Directory of Open Access Journals (Sweden)

    Kusmaningrum Soemadi

    2014-12-01

    Full Text Available This research deals with an overhaul-replacement policy for a repairable machine sold with Free Replacement Warranty (FRW. The machine will be used for a finite horizon, T (T <, and evaluated at a fixed interval, s (s< T. At each evaluation point, the buyer considers three alternative decisions i.e. Keep the machine, Overhaul it, or Replace it with a new identical one. An overhaul can reduce the machine age virtually, but not to a point that the machine is as good as new. If the machine fails during the warranty period, it is rectified at no cost to the buyer. Any failure occurring before and after the expiry of the warranty is restored by minimal repair. An overhaul-replacement policy is formulated for such machines by using dynamic programming approach to obtain the buyer’s optimal policy. The results show that a significant rejuvenation effect due to overhaul may extend the length of machine life cycle and delay the replacement decision. In contrast, the warranty stimulates early machine replacement and by then increases the replacement frequencies for a certain range of replacement cost. This demonstrates that to minimize the total ownership cost over T the buyer needs to consider the minimal repair cost reduction due to rejuvenation effect of overhaul as well as the warranty benefit due to replacement. Numerical examples are presented for both illustrating the optimal policy and describing the behavior of the optimal solution.

  13. Antioxidant Capacity and Metal Content of Physalis Peruviana L. Fruit Sold in Markets

    Directory of Open Access Journals (Sweden)

    Ayse Eken

    2014-12-01

    Full Text Available Aim: The dietary intake of medicinal food with antioxidant activity and required amounts of trace elements is important to pursue good healthy life. In our study, we aimed to determine the antioxidant capacity and metal content of goldenberry (Physalis peruviana L. fruit sold in markets in Kayseri. Material and Method: The antioxidant capacity of P. peruviana fruit was determined by the 2,2-diphenyl-1-picrylhydrazyl (DPPH free radical scavenging assay. The DPPH radical scavenger capacity of the methanol extract of fruit was compared with known antioxidants such as ascorbic acid, gallic acid, and butylated hydroxytoluene (BHT as references. The metal content of P. peruviana fruit was measured by using atomic absorption spectrometer (AAS. Results: The fruit of P. peruviana was found to possess DPPH free radical scavenging activity but the antioxidant capacity was lower than the standard substances. Inhibitory concentration 50% (IC50 values of P. peruviana, ascorbic acid, gallic acid, and BHT were determined as 32 mg/ml, 3.8 mg/ml, 3.51 mg/ml, and 1.21 mg/ml, respectively. As a result of the analysis by AAS, it was observed that P. peruviana fruit contented plentiful trace elements and the content of heavy metal was small amount or not detected. Discussion: These observations suggest that the fruit of P. peruviana has a potential source of antioxidant and trace elements of natural origin.

  14. STATYBINIŲ MEDŽIAGŲ KONKURENCINGUMAS IR TENDENCIJOS

    OpenAIRE

    Kontrimas, Robertas

    2010-01-01

    Darbe analizuojamas statybinių medžiagų konkurencingumas, nustatyti statybinių medžiagų konkurencingumą įtakojantys veiksniai ir pateikti pasiūlymai rinkos gerinimui. Pasitvirtino hipotezė, kad statybinių medžiagų paklausą ir kainas įtakoja klientų poreikiai ir jų finansinės galimybės, tačiau pasaulinės krizės įtaka yra labai ženkli,. Atlikta darbuotojų ir pirkėjų apklausa padėjo nustatyti, kokios statybinės medžiagos dažniausiai yra perkamos, kaip klientai ir darbuotojai vertina įmonę ir jos...

  15. Active spectral imaging nondestructive evaluation (SINDE) camera

    Energy Technology Data Exchange (ETDEWEB)

    Simova, E.; Rochefort, P.A., E-mail: eli.simova@cnl.ca [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada)

    2016-06-15

    A proof-of-concept video camera for active spectral imaging nondestructive evaluation has been demonstrated. An active multispectral imaging technique has been implemented in the visible and near infrared by using light emitting diodes with wavelengths spanning from 400 to 970 nm. This shows how the camera can be used in nondestructive evaluation to inspect surfaces and spectrally identify materials and corrosion. (author)

  16. High resolution RGB color line scan camera

    Science.gov (United States)

    Lynch, Theodore E.; Huettig, Fred

    1998-04-01

    A color line scan camera family which is available with either 6000, 8000 or 10000 pixels/color channel, utilizes off-the-shelf lenses, interfaces with currently available frame grabbers, includes on-board pixel by pixel offset correction, and is configurable and controllable via RS232 serial port for computer controlled or stand alone operation is described in this paper. This line scan camera is based on an available 8000 element monochrome line scan camera designed by AOA for OEM use. The new color version includes improvements such as better packaging and additional user features which make the camera easier to use. The heart of the camera is a tri-linear CCD sensor with on-chip color balancing for maximum accuracy and pinned photodiodes for low lag response. Each color channel is digitized to 12 bits and all three channels are multiplexed together so that the resulting camera output video is either a 12 or 8 bit data stream at a rate of up to 24Megpixels/sec. Conversion from 12 to 8 bit, or user-defined gamma, is accomplished by on board user-defined video look up tables. The camera has two user-selectable operating modes; lows speed, high sensitivity mode or high speed, reduced sensitivity mode. The intended uses of the camera include industrial inspection, digital archiving, document scanning, and graphic arts applications.

  17. Ultra fast x-ray streak camera

    International Nuclear Information System (INIS)

    Coleman, L.W.; McConaghy, C.F.

    1975-01-01

    A unique ultrafast x-ray sensitive streak camera, with a time resolution of 50psec, has been built and operated. A 100A thick gold photocathode on a beryllium vacuum window is used in a modified commerical image converter tube. The X-ray streak camera has been used in experiments to observe time resolved emission from laser-produced plasmas. (author)

  18. An Open Standard for Camera Trap Data

    Directory of Open Access Journals (Sweden)

    Tavis Forrester

    2016-12-01

    Full Text Available Camera traps that capture photos of animals are a valuable tool for monitoring biodiversity. The use of camera traps is rapidly increasing and there is an urgent need for standardization to facilitate data management, reporting and data sharing. Here we offer the Camera Trap Metadata Standard as an open data standard for storing and sharing camera trap data, developed by experts from a variety of organizations. The standard captures information necessary to share data between projects and offers a foundation for collecting the more detailed data needed for advanced analysis. The data standard captures information about study design, the type of camera used, and the location and species names for all detections in a standardized way. This information is critical for accurately assessing results from individual camera trapping projects and for combining data from multiple studies for meta-analysis. This data standard is an important step in aligning camera trapping surveys with best practices in data-intensive science. Ecology is moving rapidly into the realm of big data, and central data repositories are becoming a critical tool and are emerging for camera trap data. This data standard will help researchers standardize data terms, align past data to new repositories, and provide a framework for utilizing data across repositories and research projects to advance animal ecology and conservation.

  19. Laser scanning camera inspects hazardous area

    International Nuclear Information System (INIS)

    Fryatt, A.; Miprode, C.

    1985-01-01

    Main operational characteristics of a new laser scanning camera are presented. The camera is intended primarily for low level high resolution viewing inside nuclear reactors. It uses a He-Ne laser beam raster; by detecting the reflected light by means of a phomultiplier, the subject under observation can be reconstructed in an electronic video store and reviewed on a conventional monitor screen

  20. Single chip camera active pixel sensor

    Science.gov (United States)

    Shaw, Timothy (Inventor); Pain, Bedabrata (Inventor); Olson, Brita (Inventor); Nixon, Robert H. (Inventor); Fossum, Eric R. (Inventor); Panicacci, Roger A. (Inventor); Mansoorian, Barmak (Inventor)

    2003-01-01

    A totally digital single chip camera includes communications to operate most of its structure in serial communication mode. The digital single chip camera include a D/A converter for converting an input digital word into an analog reference signal. The chip includes all of the necessary circuitry for operating the chip using a single pin.

  1. Securing Embedded Smart Cameras with Trusted Computing

    Directory of Open Access Journals (Sweden)

    Winkler Thomas

    2011-01-01

    Full Text Available Camera systems are used in many applications including video surveillance for crime prevention and investigation, traffic monitoring on highways or building monitoring and automation. With the shift from analog towards digital systems, the capabilities of cameras are constantly increasing. Today's smart camera systems come with considerable computing power, large memory, and wired or wireless communication interfaces. With onboard image processing and analysis capabilities, cameras not only open new possibilities but also raise new challenges. Often overlooked are potential security issues of the camera system. The increasing amount of software running on the cameras turns them into attractive targets for attackers. Therefore, the protection of camera devices and delivered data is of critical importance. In this work we present an embedded camera prototype that uses Trusted Computing to provide security guarantees for streamed videos. With a hardware-based security solution, we ensure integrity, authenticity, and confidentiality of videos. Furthermore, we incorporate image timestamping, detection of platform reboots, and reporting of the system status. This work is not limited to theoretical considerations but also describes the implementation of a prototype system. Extensive evaluation results illustrate the practical feasibility of the approach.

  2. Centering mount for a gamma camera

    International Nuclear Information System (INIS)

    Mirkhodzhaev, A.Kh.; Kuznetsov, N.K.; Ostryj, Yu.E.

    1988-01-01

    A device for centering a γ-camera detector in case of radionuclide diagnosis is described. It permits the use of available medical coaches instead of a table with a transparent top. The device can be used for centering a detector (when it is fixed at the low end of a γ-camera) on a required area of the patient's body

  3. Digital airborne camera introduction and technology

    CERN Document Server

    Sandau, Rainer

    2014-01-01

    The last decade has seen great innovations on the airborne camera. This book is the first ever written on the topic and describes all components of a digital airborne camera ranging from the object to be imaged to the mass memory device.

  4. Adapting virtual camera behaviour through player modelling

    DEFF Research Database (Denmark)

    Burelli, Paolo; Yannakakis, Georgios N.

    2015-01-01

    Research in virtual camera control has focused primarily on finding methods to allow designers to place cameras effectively and efficiently in dynamic and unpredictable environments, and to generate complex and dynamic plans for cinematography in virtual environments. In this article, we propose...

  5. Driving with head-slaved camera system

    NARCIS (Netherlands)

    Oving, A.B.; Erp, J.B.F. van

    2001-01-01

    In a field experiment, we tested the effectiveness of a head-slaved camera system for driving an armoured vehicle under armour. This system consists of a helmet-mounted display (HMD), a headtracker, and a motion platform with two cameras. Subjects performed several driving tasks on paved and in

  6. Rosetta Star Tracker and Navigation Camera

    DEFF Research Database (Denmark)

    Thuesen, Gøsta

    1998-01-01

    Proposal in response to the Invitation to Tender (ITT) issued by Matra Marconi Space (MSS) for the procurement of the ROSETTA Star Tracker and Navigation Camera.......Proposal in response to the Invitation to Tender (ITT) issued by Matra Marconi Space (MSS) for the procurement of the ROSETTA Star Tracker and Navigation Camera....

  7. Hermann agreement updates IRS guidelines for incentives.

    Science.gov (United States)

    Broccolo, B M; Peregrine, M W

    1995-01-01

    The October 1994 agreement between the Internal Revenue Service (IRS) and Hermann Hospital of Houston, Texas, elucidates current IRS policy on physician recruitment incentives. The IRS distinguishes between the recruiting and the retention of physicians and perimts incentives beyond reasonable compensation in the former but not the latter circumstance. This new agreement, while not legally precedential, nevertheless provides guidance for healthcare organizations seeking safe harbor protection.

  8. Test and evaluation of IR detectors and arrays II; Proceedings of the Meeting, Orlando, FL, Apr. 22, 23, 1992

    Science.gov (United States)

    Hoke, Forney M.

    The present conference discusses a radiometric calibration system for IR cameras, a methodology for testing IR focal-plane arrays in simulated nuclear radiation environments, process optimization for Si:As In-bumped focal-plane arrays, precise MTF measurements for focal-plane arrays, and IR focal-plane array crosstalk measurement. Also discussed are an imaging metric for IR focal-plane arrays, optical stimuli for high-volume automated testing of 2D HgCdTe focal-plane arrays, the evaluation of a solid-state photomultiplier focal-plane array for SDI, spectral effects on bulk photoconductors operated at cryogenic temperatures, and a novel technique for measuring the ionizing radiation effects in MOS transistors.

  9. Wavefront analysis for plenoptic camera imaging

    International Nuclear Information System (INIS)

    Luan Yin-Sen; Xu Bing; Yang Ping; Tang Guo-Mao

    2017-01-01

    The plenoptic camera is a single lens stereo camera which can retrieve the direction of light rays while detecting their intensity distribution. In this paper, to reveal more truths of plenoptic camera imaging, we present the wavefront analysis for the plenoptic camera imaging from the angle of physical optics but not from the ray tracing model of geometric optics. Specifically, the wavefront imaging model of a plenoptic camera is analyzed and simulated by scalar diffraction theory and the depth estimation is redescribed based on physical optics. We simulate a set of raw plenoptic images of an object scene, thereby validating the analysis and derivations and the difference between the imaging analysis methods based on geometric optics and physical optics are also shown in simulations. (paper)

  10. Modelling Virtual Camera Behaviour Through Player Gaze

    DEFF Research Database (Denmark)

    Picardi, Andrea; Burelli, Paolo; Yannakakis, Georgios N.

    2012-01-01

    industry and game AI research focus on the devel- opment of increasingly sophisticated systems to automate the control of the virtual camera integrating artificial intel- ligence algorithms within physical simulations. However, in both industry and academia little research has been carried out......In a three-dimensional virtual environment, aspects such as narrative and interaction largely depend on the placement and animation of the virtual camera. Therefore, virtual camera control plays a critical role in player experience and, thereby, in the overall quality of a computer game. Both game...... on the relationship between virtual camera, game-play and player behaviour. We run a game user experiment to shed some light on this relationship and identify relevant dif- ferences between camera behaviours through different game sessions, playing behaviours and player gaze patterns. Re- sults show that users can...

  11. Stereo Cameras for Clouds (STEREOCAM) Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Romps, David [Univ. of California, Berkeley, CA (United States); Oktem, Rusen [Univ. of California, Berkeley, CA (United States)

    2017-10-31

    The three pairs of stereo camera setups aim to provide synchronized and stereo calibrated time series of images that can be used for 3D cloud mask reconstruction. Each camera pair is positioned at approximately 120 degrees from the other pair, with a 17o-19o pitch angle from the ground, and at 5-6 km distance from the U.S. Department of Energy (DOE) Central Facility at the Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) observatory to cover the region from northeast, northwest, and southern views. Images from both cameras of the same stereo setup can be paired together to obtain 3D reconstruction by triangulation. 3D reconstructions from the ring of three stereo pairs can be combined together to generate a 3D mask from surrounding views. This handbook delivers all stereo reconstruction parameters of the cameras necessary to make 3D reconstructions from the stereo camera images.

  12. Gamma camera performance: technical assessment protocol

    Energy Technology Data Exchange (ETDEWEB)

    Bolster, A.A. [West Glasgow Hospitals NHS Trust, London (United Kingdom). Dept. of Clinical Physics; Waddington, W.A. [University College London Hospitals NHS Trust, London (United Kingdom). Inst. of Nuclear Medicine

    1996-12-31

    This protocol addresses the performance assessment of single and dual headed gamma cameras. No attempt is made to assess the performance of any associated computing systems. Evaluations are usually performed on a gamma camera commercially available within the United Kingdom and recently installed at a clinical site. In consultation with the manufacturer, GCAT selects the site and liaises with local staff to arrange a mutually convenient time for assessment. The manufacturer is encouraged to have a representative present during the evaluation. Three to four days are typically required for the evaluation team to perform the necessary measurements. When access time is limited, the team will modify the protocol to test the camera as thoroughly as possible. Data are acquired on the camera`s computer system and are subsequently transferred to the independent GCAT computer system for analysis. This transfer from site computer to the independent system is effected via a hardware interface and Interfile data transfer. (author).

  13. OH/IR stars in the Galaxy

    International Nuclear Information System (INIS)

    Baud, B.

    1978-01-01

    Radio astronomical observations leading to the discovery of 71 OH/IR sources are described in this thesis. These OH/IR sources are characterized by their double peaked OH emission profile at a wavelength of 18 cm and by their strong IR infrared emission. An analysis of the distribution and radial velocities of a number of previously known and new OH/IR sources was performed. The parameter ΔV (the velocity separation between two emission peaks of the 18 cm line profile) was found to be a good criterion for a population classification with respect to stellar age

  14. Cost effective system for monitoring of fish migration with a camera

    Science.gov (United States)

    Sečnik, Matej; Brilly, Mitja; Vidmar, Andrej

    2016-04-01

    Within the European LIFE project Ljubljanica connects (LIFE10 NAT/SI/000142) we have developed a cost-effective solution for the monitoring of fish migration through the fish passes with the underwater camera. In the fish pass at Ambrožev trg and in the fish pass near the Fužine castle we installed a video camera called "Fishcam" to be able to monitor the migration of fish through the fish passes and success of its reconstruction. Live stream from fishcams installed in the fishpassesis available on our project website (http://ksh.fgg.uni-lj.si/ljubljanicaconnects/ang/12_camera). The system for the fish monitoring is made from two parts. First is the waterproof box for the computer with charger and the second part is the camera itself. We used a high sensitive Sony analogue camera. The advantage of this camera is that it has very good sensitivity in low light conditions, so it can take good quality pictures even at night with a minimum additional lighting. For the night recording we use additional IR reflector to illuminate passing fishes. The camera is connected to an 8-inch tablet PC. We decided to use a tablet PC because it is quite small, cheap, it is relatively fast and has a low power consumption. On the computer we use software which has advanced motion detection capabilities, so we can also detect the small fishes. When the fish is detected by a software, its photograph is automatically saved to local hard drive and for backup also on Google drive. The system for monitoring of fish migration has turned out to work very well. From the beginning of monitoring in June 2015 to end of the year there were more than 100.000 photographs produced. The first analysis of them was already prepared estimating fish species and their frequency in passing the fish pass.

  15. Development of high-speed video cameras

    Science.gov (United States)

    Etoh, Takeharu G.; Takehara, Kohsei; Okinaka, Tomoo; Takano, Yasuhide; Ruckelshausen, Arno; Poggemann, Dirk

    2001-04-01

    Presented in this paper is an outline of the R and D activities on high-speed video cameras, which have been done in Kinki University since more than ten years ago, and are currently proceeded as an international cooperative project with University of Applied Sciences Osnabruck and other organizations. Extensive marketing researches have been done, (1) on user's requirements on high-speed multi-framing and video cameras by questionnaires and hearings, and (2) on current availability of the cameras of this sort by search of journals and websites. Both of them support necessity of development of a high-speed video camera of more than 1 million fps. A video camera of 4,500 fps with parallel readout was developed in 1991. A video camera with triple sensors was developed in 1996. The sensor is the same one as developed for the previous camera. The frame rate is 50 million fps for triple-framing and 4,500 fps for triple-light-wave framing, including color image capturing. Idea on a video camera of 1 million fps with an ISIS, In-situ Storage Image Sensor, was proposed in 1993 at first, and has been continuously improved. A test sensor was developed in early 2000, and successfully captured images at 62,500 fps. Currently, design of a prototype ISIS is going on, and, hopefully, will be fabricated in near future. Epoch-making cameras in history of development of high-speed video cameras by other persons are also briefly reviewed.

  16. Cloud Computing with Context Cameras

    Science.gov (United States)

    Pickles, A. J.; Rosing, W. E.

    2016-05-01

    We summarize methods and plans to monitor and calibrate photometric observations with our autonomous, robotic network of 2m, 1m and 40cm telescopes. These are sited globally to optimize our ability to observe time-variable sources. Wide field "context" cameras are aligned with our network telescopes and cycle every ˜2 minutes through BVr'i'z' filters, spanning our optical range. We measure instantaneous zero-point offsets and transparency (throughput) against calibrators in the 5-12m range from the all-sky Tycho2 catalog, and periodically against primary standards. Similar measurements are made for all our science images, with typical fields of view of ˜0.5 degrees. These are matched against Landolt, Stetson and Sloan standards, and against calibrators in the 10-17m range from the all-sky APASS catalog. Such measurements provide pretty good instantaneous flux calibration, often to better than 5%, even in cloudy conditions. Zero-point and transparency measurements can be used to characterize, monitor and inter-compare sites and equipment. When accurate calibrations of Target against Standard fields are required, monitoring measurements can be used to select truly photometric periods when accurate calibrations can be automatically scheduled and performed.

  17. Atmospheric Entry Experiments at IRS

    Science.gov (United States)

    Auweter-Kurtz, M.; Endlich, P.; Herdrich, G.; Kurtz, H.; Laux, T.; Löhle, S.; Nazina, N.; Pidan, S.

    2002-01-01

    Entering the atmosphere of celestial bodies, spacecrafts encounter gases at velocities of several km/s, thereby being subjected to great heat loads. The thermal protection systems and the environment (plasma) have to be investigated by means of computational and ground facility based simulations. For more than a decade, plasma wind tunnels at IRS have been used for the investigation of TPS materials. Nevertheless, ground tests and computer simulations cannot re- place space flights completely. Particularly, entry mission phases encounter challenging problems, such as hypersonic aerothermodynamics. Concerning the TPS, radiation-cooled materials used for reuseable spacecrafts and ablator tech- nologies are of importance. Besides the mentioned technologies, there is the goal to manage guidance navigation, con- trol, landing technology and inflatable technologies such as ballutes that aim to keep vehicles in the atmosphere without landing. The requirement to save mass and energy for planned interplanetary missions such as Mars Society Balloon Mission, Mars Sample Return Mission, Mars Express or Venus Sample Return mission led to the need for manoeuvres like aerocapture, aero-breaking and hyperbolic entries. All three are characterized by very high kinetic vehicle energies to be dissipated by the manoeuvre. In this field flight data are rare. The importance of these manoeuvres and the need to increase the knowledge of required TPS designs and behavior during such mission phases point out the need of flight experiments. As result of the experience within the plasma diagnostic tool development and the plasma wind tunnel data base, flight experiments like the PYrometric RE-entry EXperiment PYREX were developed, fully qualified and successfully flown. Flight experiments such as the entry spectrometer RESPECT and PYREX on HOPE-X are in the conceptual phase. To increase knowledge in the scope of atmospheric manoeuvres and entries, data bases have to be created combining both

  18. Towards Adaptive Virtual Camera Control In Computer Games

    DEFF Research Database (Denmark)

    Burelli, Paolo; Yannakakis, Georgios N.

    2011-01-01

    Automatic camera control aims to define a framework to control virtual camera movements in dynamic and unpredictable virtual environments while ensuring a set of desired visual properties. We inves- tigate the relationship between camera placement and playing behaviour in games and build a user...... model of the camera behaviour that can be used to control camera movements based on player preferences. For this purpose, we collect eye gaze, camera and game-play data from subjects playing a 3D platform game, we cluster gaze and camera information to identify camera behaviour profiles and we employ...... camera control in games is discussed....

  19. Reducing the Variance of Intrinsic Camera Calibration Results in the ROS Camera_Calibration Package

    Science.gov (United States)

    Chiou, Geoffrey Nelson

    The intrinsic calibration of a camera is the process in which the internal optical and geometric characteristics of the camera are determined. If accurate intrinsic parameters of a camera are known, the ray in 3D space that every point in the image lies on can be determined. Pairing with another camera allows for the position of the points in the image to be calculated by intersection of the rays. Accurate intrinsics also allow for the position and orientation of a camera relative to some world coordinate system to be calculated. These two reasons for having accurate intrinsic calibration for a camera are especially important in the field of industrial robotics where 3D cameras are frequently mounted on the ends of manipulators. In the ROS (Robot Operating System) ecosystem, the camera_calibration package is the default standard for intrinsic camera calibration. Several researchers from the Industrial Robotics & Automation division at Southwest Research Institute have noted that this package results in large variances in the intrinsic parameters of the camera when calibrating across multiple attempts. There are also open issues on this matter in their public repository that have not been addressed by the developers. In this thesis, we confirm that the camera_calibration package does indeed return different results across multiple attempts, test out several possible hypothesizes as to why, identify the reason, and provide simple solution to fix the cause of the issue.

  20. Teaching IR to Medical Students: A Call to Action.

    Science.gov (United States)

    Lee, Aoife M; Lee, Michael J

    2018-02-01

    Interventional radiology (IR) has grown rapidly over the last 20 years and is now an essential component of modern medicine. Despite IR's increasing penetration and reputation in healthcare systems, IR is poorly taught, if taught at all, in most medical schools. Medical students are the referrers of tomorrow and potential IR recruits and deserve to be taught IR by expert IRs. The lack of formal IR teaching curricula in many medical schools needs to be addressed urgently for the continued development and dissemination of, particularly acute, IR services throughout Europe. We call on IRs to take up the baton to teach IR to the next generation of doctors.

  1. Simulation of Thermal Processes in Metamaterial MM-to-IR Converter for MM-wave Imager

    International Nuclear Information System (INIS)

    Zagubisalo, Peter S; Paulish, Andrey G; Kuznetsov, Sergey A

    2014-01-01

    The main characteristics of MM-wave image detector were simulated by means of accurate numerical modelling of thermophysical processes in a metamaterial MM-to-IR converter. The converter represents a multilayer structure consisting of an ultra thin resonant metamaterial absorber and a perfect emissive layer. The absorber consists of a dielectric self-supporting film that is metallized from both sides. A micro-pattern is fabricated from one side. Resonant absorption of the MM waves induces the converter heating that yields enhancement of IR emission from the emissive layer. IR emission is detected by IR camera. In this contribution an accurate numerical model for simulation of the thermal processes in the converter structure was created by using COMSOL Multiphysics software. The simulation results are in a good agreement with experimental results that validates the model. The simulation shows that the real time operation is provided for the converter thickness less than 3 micrometers and time response can be improved by decreasing of the converter thickness. The energy conversion efficiency of MM waves into IR radiation is over 80%. The converter temperature increase is a linear function of a MM-wave radiation power within three orders of the dynamic range. The blooming effect and ways of its reducing are also discussed. The model allows us to choose the ways of converter structure optimization and improvement of image detector parameters

  2. Initial study of a method for IR measurements in boilers; Inledande studie av metod foer IR-maetning i aangpannor

    Energy Technology Data Exchange (ETDEWEB)

    Sandberg, Martin; Joensson, Magnus; Lundin, Leif [Swedish National Testing and Research Inst., Boraas (Sweden)

    1999-10-01

    The tubes in steam boilers are required to be regularly inspected, in order to find water-side deposits, thinning of walls or material defects. This is for safety, problem-free operation and high availability. No non-destructive method of inspection is available today for finding deposits on the insides of boiler tubes. Nor is there any method that can not only detect deposits on the insides of the tubes but also monitor the tubes' wall thicknesses. A suitable method - reliable, safe, easy to use and cost-efficient - is therefore needed. One such method is to measure the surface temperature of a larger area of the diaphragm wall, using a non-contact method, and from the resulting information to assess the material thickness and possible water-side or steam-side deposits. An IR camera is used for non-contact measurement of the radiated energy from several adjacent surface elements, and thus also of their temperature. The temperature is displayed on the camera's screen to produce a picture of the temperature distribution. This is a well-established method today, and is used in applications such as the steel industry, the electricity industry, electronics and health care. The surface temperatures of the tube walls can be measured by inserting an IR camera on an arm into the combustion chamber, without anyone having to get inside the boiler. The combustion chamber is the part of the boiler that is of main interest for inspection, as it is the easiest to reach. Measurements are facilitated by higher temperatures and thus higher heat fluxes through the tube walls. Diaphragm wall temperatures can be measured quickly and rationally over large areas. Points of interest in inspections include determining where there are water-side deposits in the tubes, where tubes are thin, where flow is obstructed and where there might be material defects. With the exception of material defects, all of these mechanisms result in changes in the surface temperature, which in many

  3. Autonomous Multicamera Tracking on Embedded Smart Cameras

    Directory of Open Access Journals (Sweden)

    Bischof Horst

    2007-01-01

    Full Text Available There is currently a strong trend towards the deployment of advanced computer vision methods on embedded systems. This deployment is very challenging since embedded platforms often provide limited resources such as computing performance, memory, and power. In this paper we present a multicamera tracking method on distributed, embedded smart cameras. Smart cameras combine video sensing, processing, and communication on a single embedded device which is equipped with a multiprocessor computation and communication infrastructure. Our multicamera tracking approach focuses on a fully decentralized handover procedure between adjacent cameras. The basic idea is to initiate a single tracking instance in the multicamera system for each object of interest. The tracker follows the supervised object over the camera network, migrating to the camera which observes the object. Thus, no central coordination is required resulting in an autonomous and scalable tracking approach. We have fully implemented this novel multicamera tracking approach on our embedded smart cameras. Tracking is achieved by the well-known CamShift algorithm; the handover procedure is realized using a mobile agent system available on the smart camera network. Our approach has been successfully evaluated on tracking persons at our campus.

  4. Automatic camera tracking for remote manipulators

    International Nuclear Information System (INIS)

    Stoughton, R.S.; Martin, H.L.; Bentz, R.R.

    1984-04-01

    The problem of automatic camera tracking of mobile objects is addressed with specific reference to remote manipulators and using either fixed or mobile cameras. The technique uses a kinematic approach employing 4 x 4 coordinate transformation matrices to solve for the needed camera PAN and TILT angles. No vision feedback systems are used, as the required input data are obtained entirely from position sensors from the manipulator and the camera-positioning system. All hardware requirements are generally satisfied by currently available remote manipulator systems with a supervisory computer. The system discussed here implements linear plus on/off (bang-bang) closed-loop control with a +-2 0 deadband. The deadband area is desirable to avoid operator seasickness caused by continuous camera movement. Programming considerations for camera control, including operator interface options, are discussed. The example problem presented is based on an actual implementation using a PDP 11/34 computer, a TeleOperator Systems SM-229 manipulator, and an Oak Ridge National Laboratory (ORNL) camera-positioning system. 3 references, 6 figures, 2 tables

  5. Automatic camera tracking for remote manipulators

    International Nuclear Information System (INIS)

    Stoughton, R.S.; Martin, H.L.; Bentz, R.R.

    1984-07-01

    The problem of automatic camera tracking of mobile objects is addressed with specific reference to remote manipulators and using either fixed or mobile cameras. The technique uses a kinematic approach employing 4 x 4 coordinate transformation matrices to solve for the needed camera PAN and TILT angles. No vision feedback systems are used, as the required input data are obtained entirely from position sensors from the manipulator and the camera-positioning system. All hardware requirements are generally satisfied by currently available remote manipulator systems with a supervisory computer. The system discussed here implements linear plus on/off (bang-bang) closed-loop control with a +-2-deg deadband. The deadband area is desirable to avoid operator seasickness caused by continuous camera movement. Programming considerations for camera control, including operator interface options, are discussed. The example problem presented is based on an actual implementation using a PDP 11/34 computer, a TeleOperator Systems SM-229 manipulator, and an Oak Ridge National Laboratory (ORNL) camera-positioning system. 3 references, 6 figures, 2 tables

  6. New camera systems for fuel services

    International Nuclear Information System (INIS)

    Hummel, W.; Beck, H.J.

    2010-01-01

    AREVA NP Fuel Services have many years of experience in visual examination and measurements on fuel assemblies and associated core components by using state of the art cameras and measuring technologies. The used techniques allow the surface and dimensional characterization of materials and shapes by visual examination. New enhanced and sophisticated technologies for fuel services f. e. are two shielded color camera systems for use under water and close inspection of a fuel assembly. Nowadays the market requirements for detecting and characterization of small defects (lower than the 10th of one mm) or cracks and analyzing surface appearances on an irradiated fuel rod cladding or fuel assembly structure parts have increased. Therefore it is common practice to use movie cameras with higher resolution. The radiation resistance of high resolution CCD cameras is in general very low and it is not possible to use them unshielded close to a fuel assembly. By extending the camera with a mirror system and shielding around the sensitive parts, the movie camera can be utilized for fuel assembly inspection. AREVA NP Fuel Services is now equipped with such kind of movie cameras. (orig.)

  7. First results from the TOPSAT camera

    Science.gov (United States)

    Greenway, Paul; Tosh, Ian; Morris, Nigel; Burton, Gary; Cawley, Steve

    2017-11-01

    The TopSat camera is a low cost remote sensing imager capable of producing 2.5 metre resolution panchromatic imagery, funded by the British National Space Centre's Mosaic programme. The instrument was designed and assembled at the Space Science & Technology Department of the CCLRC's Rutherford Appleton Laboratory (RAL) in the UK, and was launched on the 27th October 2005 from Plesetsk Cosmodrome in Northern Russia on a Kosmos-3M. The camera utilises an off-axis three mirror system, which has the advantages of excellent image quality over a wide field of view, combined with a compactness that makes its overall dimensions smaller than its focal length. Keeping the costs to a minimum has been a major design driver in the development of this camera. The camera is part of the TopSat mission, which is a collaboration between four UK organisations; QinetiQ, Surrey Satellite Technology Ltd (SSTL), RAL and Infoterra. Its objective is to demonstrate provision of rapid response high resolution imagery to fixed and mobile ground stations using a low cost minisatellite. The paper "Development of the TopSat Camera" presented by RAL at the 5th ICSO in 2004 described the opto-mechanical design, assembly, alignment and environmental test methods implemented. Now that the spacecraft is in orbit and successfully acquiring images, this paper presents the first results from the camera and makes an initial assessment of the camera's in-orbit performance.

  8. State of art in radiation tolerant camera

    Energy Technology Data Exchange (ETDEWEB)

    Choi; Young Soo; Kim, Seong Ho; Cho, Jae Wan; Kim, Chang Hoi; Seo, Young Chil

    2002-02-01

    Working in radiation environment such as nuclear power plant, RI facility, nuclear fuel fabrication facility, medical center has to be considered radiation exposure, and we can implement these job by remote observation and operation. However the camera used for general industry is weakened at radiation, so radiation-tolerant camera is needed for radiation environment. The application of radiation-tolerant camera system is nuclear industry, radio-active medical, aerospace, and so on. Specially nuclear industry, the demand is continuous in the inspection of nuclear boiler, exchange of pellet, inspection of nuclear waste. In the nuclear developed countries have been an effort to develop radiation-tolerant cameras. Now they have many kinds of radiation-tolerant cameras which can tolerate to 10{sup 6}-10{sup 8} rad total dose. In this report, we examine into the state-of-art about radiation-tolerant cameras, and analyze these technology. We want to grow up the concern of developing radiation-tolerant camera by this paper, and upgrade the level of domestic technology.

  9. Morphological and chemical analyses of Eriocauli Flos sold in Taiwan markets

    Directory of Open Access Journals (Sweden)

    I-Jung Lee

    2017-10-01

    Full Text Available Eriocauli Flos (Gujingcao; EF, the dried capitulum with the peduncle of Eriocaulon buergerianum Koern. (Eriocaulaceae, is a Chinese herbal medicine for treating eye diseases and inflammation. However, several species of the Eriocaulon genus are used as substitutes in different areas. To examine the species of EF used in Taiwan and to establish the quality control platform, morphological and chemical analyses have been performed. Ten major compounds, including apigenin (7 and its 7-O-β-D-glucopyranoside (1 and 7-O-(6-O-E-coumaroyl-β-D-glucopyranoside (6, hispidulin (8 and its 7-O-β-D-glucopyranoside (2 and 7-O-(6-O-E-coumaroyl-β-D-glucopyranoside (5, jaceosidin (9 and its 7-O-β-D-glucopyranoside (3, and toralactone (10 and its 9-O-β-D-glucopyranosyl(1→6-β-D-glucopyranoside (4, were isolated and identified from commercially available EF. Morphological investigation showed that two kinds of EFs and most of the EFs sold in Taiwan herbal markets are capitulum without the peduncle. A simultaneous high performance liquid chromatography and ultra performance liquid chromatography analyses of multiple components (1–10 in commercially available EFs, collected from different areas of Taiwan, was conducted. Results showed wide variations in morphology and chemical profiles between capitulum with and without the peduncle. In comparison with an authentic E. buergerianum, we found not only the morphology but also the chemical profile was different from both collected samples. In terms of the morphological examination, the samples without peduncle are closer to the authentic one. To ensure the correct EF materia medica is used in Taiwan so as to guarantee their therapeutic efficacy in clinical practice, further monitoring is necessary.

  10. Four-year monitoring of foodborne pathogens in raw milk sold by vending machines in Italy.

    Science.gov (United States)

    Giacometti, Federica; Bonilauri, Paolo; Serraino, Andrea; Peli, Angelo; Amatiste, Simonetta; Arrigoni, Norma; Bianchi, Manila; Bilei, Stefano; Cascone, Giuseppe; Comin, Damiano; Daminelli, Paolo; Decastelli, Lucia; Fustini, Mattia; Mion, Renzo; Petruzzelli, Annalisa; Rosmini, Roberto; Rugna, Gianluca; Tamba, Marco; Tonucci, Franco; Bolzoni, Giuseppe

    2013-11-01

    Prevalence data were collected from official microbiological records monitoring four selected foodborne pathogens (Salmonella, Listeria monocytogenes, Escherichia coli O157:H7, and Campylobacter jejuni) in raw milk sold by self-service vending machines in seven Italian regions (60,907 samples from 1,239 vending machines) from 2008 to 2011. Data from samples analyzed by both culture-based and real-time PCR methods were collected in one region. One hundred raw milk consumers in four regions were interviewed while purchasing raw milk from vending machines. One hundred seventy-eight of 60,907 samples were positive for one of the four foodborne pathogens investigated: 18 samples were positive for Salmonella, 83 for L. monocytogenes, 24 for E. coli O157:H7, and 53 for C. jejuni in the seven regions investigated. No significant differences in prevalence were found among regions, but a significant increase in C. jejuni prevalence was observed over the years of the study. A comparison of the two analysis methods revealed that real-time PCR was 2.71 to 9.40 times more sensitive than the culture-based method. Data on consumer habits revealed that some behaviors may enhance the risk of infection linked to raw milk consumption: 37% of consumers did not boil milk before consumption, 93% never used an insulated bag to transport raw milk home, and raw milk was consumed by children younger than 5 years of age. These results emphasize that end-product controls alone are not sufficient to guarantee an adequate level of consumer protection. The beta distribution of positive samples in this study and the data on raw milk consumer habits will be useful for the development of a national quantitative risk assessment of Salmonella, L. monocytogenes, E. coli O157, and C. jejuni infection associated with raw milk consumption.

  11. Concentration of ions in selected bottled water samples sold in Malaysia

    Science.gov (United States)

    Aris, Ahmad Zaharin; Kam, Ryan Chuan Yang; Lim, Ai Phing; Praveena, Sarva Mangala

    2013-03-01

    Many consumers around the world, including Malaysians, have turned to bottled water as their main source of drinking water. The aim of this study is to determine the physical and chemical properties of bottled water samples sold in Selangor, Malaysia. A total of 20 bottled water brands consisting of `natural mineral (NM)' and `packaged drinking (PD)' types were randomly collected and analyzed for their physical-chemical characteristics: hydrogen ion concentration (pH), electrical conductivity (EC) and total dissolved solids (TDS), selected major ions: calcium (Ca), potassium (K), magnesium (Mg) and sodium (Na), and minor trace constituents: copper (Cu) and zinc (Zn) to ascertain their suitability for human consumption. The results obtained were compared with guideline values recommended by World Health Organization (WHO) and Malaysian Ministry of Health (MMOH), respectively. It was found that all bottled water samples were in accordance with the guidelines set by WHO and MMOH except for one sample (D3) which was below the pH limit of 6.5. Both NM and PD bottled water were dominated by Na + K > Ca > Mg. Low values for EC and TDS in the bottled water samples showed that water was deficient in essential elements, likely an indication that these were removed by water treatment. Minerals like major ions were present in very low concentrations which could pose a risk to individuals who consume this water on a regular basis. Generally, the overall quality of the supplied bottled water was in accordance to standards and guidelines set by WHO and MMOH and safe for consumption.

  12. Premier's imaging IR limb sounder

    Science.gov (United States)

    Kraft, Stefan; Bézy, Jean-Loup; Meynart, Roland; Langen, Jörg; Carnicero Dominguez, Bernardo; Bensi, Paolo; Silvestrin, Pierluigi

    2017-11-01

    The Imaging IR Limb Sounder (IRLS) is one of the two instruments planned on board of the candidate Earth Explorer Core Mission PREMIER. PREMIER stands for PRocess Exploration through Measurements of Infrared and Millimetre-wave Emitted Radiation. PREMIER went recently through the process of a feasibility study (Phase A) within the Earth Observation Envelope Program. Emerging from recent advanced instrument technologies IRLS shall, next to a millimetre-wave limb sounder (called STEAMR), explore the benefits of three-dimensional limb sounding with embedded cloud imaging capability. Such 3D imaging technology is expected to open a new era of limb sounding that will allow detailed studies of the link between atmospheric composition and climate, since it will map simultaneously fields of temperature and many trace gases in the mid/upper troposphere and stratosphere across a large vertical and horizontal field of view and with high vertical and horizontal resolution. PREMIER shall fly in a tandem formation looking backwards to METOP's swath and thereby improve meteorological and environmental analyses.

  13. A novel plane method to the calibration of the thermal camera

    Science.gov (United States)

    Wang, Xunsi; Huang, Wei; Nie, Qiu-hua; Xu, Tiefeng; Dai, Shixun; Shen, Xiang; Cheng, Weihai

    2009-07-01

    This paper provides an up-to-date review of research efforts in thermal camera and target object recognition techniques based on two-dimensional (2D) images in the infrared (IR) spectra (8-12μm). From the geometric point of view, a special target plate was constructed with a radiation source of lamp excited that allows all of these devices to be calibrated geometrically along a radiance-based approach. The calibration theory and actual experimental procedures were described, then an automated measurement of the circle targets by image centroid algorithm. The key parameters of IR camera were calibrated out with 3 inner and 6 outer of Tsai model in thermal imaging. The subsequent data processing and analysis were then outlined. The 3D model from the successful calibration of a representative sample of the infrared array camera was presented and discussed. They provide much new and easy way to the geometric characteristics of these imagers that can be used in car-night-vision, medical, industrial, military, and environmental applications.

  14. Atom condensation on an atomically smooth surface: Ir, Re, W, and Pd on Ir(111)

    International Nuclear Information System (INIS)

    Wang, S.C.; Ehrlich, G.

    1991-01-01

    The distribution of condensing metal atoms over the two types of sites present on an atomically smooth Ir(111) has been measured in a field ion microscope. For Ir, Re, W, and Pd from a thermal source, condensing on Ir(111) at ∼20 K, the atoms are randomly distributed, as expected if they condense at the first site struck

  15. Biochemical applications of FT-IR spectroscopy

    NARCIS (Netherlands)

    Pistorius, A.M.A.

    1996-01-01

    This thesis describes the use of (FT-)IR spectroscopy in general biochemical research. In chapter 3, IR spectroscopy is used in the quantitation of residual detergent after reconstitution of an integral membrane protein in a pre-defined lipid matrix. This chapter discusses the choice of the

  16. How to remedy Eurocentrism in IR?

    DEFF Research Database (Denmark)

    Bilgin, Pinar

    2016-01-01

    While IR's Eurocentric limits are usually acknowledged, what those limits mean for theorizing about the international is seldom clarified. In The Global Transformation, Buzan and Lawson offer a 'composite approach' that goes some way towards addressing IR's Eurocentrism, challenging existing myth...

  17. Quantitative gas analysis with FT-IR

    DEFF Research Database (Denmark)

    Bak, J.; Larsen, A.

    1995-01-01

    Calibration spectra of CO in the 2.38-5100 ppm concentration range (22 spectra) have been measured with a spectral resolution of 4 cm(-1), in the mid-IR (2186-2001 cm(-1)) region, with a Fourier transform infrared (FT-IR) instrument. The multivariate calibration method partial least-squares (PLS1...

  18. Benzene adsorption and oxidation on Ir(111)

    NARCIS (Netherlands)

    Weststrate, C.J.; Bakker, J.W.; Gluhoi, A.C.; Ludwig, W.; Nieuwenhuys, B.E.

    2007-01-01

    Adsorption, decompn. and oxidn. of benzene on Ir(1 1 1) was studied by high resoln. (synchrotron) XPS, temp. programmed desorption and LEED. Mol. adsorption of benzene on Ir(1 1 1) is obsd. between 170 K and 350 K. Above this temp. both desorption and decompn. of benzene take place. An ordered

  19. Nutrition Standards for Food Service Guidelines for Foods Served or Sold in Municipal Government Buildings or Worksites, United States, 2014.

    Science.gov (United States)

    Onufrak, Stephen J; Zaganjor, Hatidza; Moore, Latetia V; Carlson, Susan; Kimmons, Joel; Galuska, Deborah

    2016-12-22

    The Institute of Medicine and Centers for Disease Control and Prevention have recommended that government agencies use nutrition standards for foods and beverages sold and provided at their facilities. In this study, we examine written nutrition standards for foods sold or served in local government buildings or worksites among US municipalities. We used data from a 2014 national survey of 1,945 municipal governments serving populations of 1,000 or more to assess the presence of written nutrition standards, the food groups or nutrients addressed by standards, and the populations served by facilities where standards are applied. The prevalence of standards was estimated by municipality population size, rural-urban status, census region, poverty prevalence, education level, and racial/ethnic composition. Overall, 3.2% of US municipalities reported nutrition standards with greater prevalence observed among large municipalities (12.8% of municipalities with ≥50,000 people vs 2.2% of municipalities with <2,500 people, P < .001). Prevalence differed by region, and standards were most common in the West (6.6%) and least common in the Midwest (2.0%, P = .003).The most common nutrition topics addressed in standards were offering low-calorie beverages, fruits and vegetables, and free drinking water. Most standards applied to facilities serving government employees (67%) or the general public (66%), with fewer serving institutionalized populations (23%). Few municipal governments reported having written nutrition standards for foods and beverages sold in their facilities in 2014. Implementing nutrition standards for foods sold or served by local governments is a strategy for increasing access to healthier foods and beverages among municipal employees and local residents.

  20. Pricing and sales tax collection policies for e-cigarette starter kits and disposable products sold online.

    Science.gov (United States)

    Cuomo, Raphael E; Miner, Angela; Mackey, Tim K

    2015-10-23

    Previous studies have examined marketing characteristics of e-cigarettes sold online and others have examined e-cigarettes pricing in retail (non-Internet) settings. This study expands on these findings by examining pricing and marketing characteristics of interest among e-cigarette online vendors. Structured web searches were conducted from August-September 2014 to identify popular e-cigarette Internet vendors. We then collected pricing data (e-cigarette starter kits and disposables), sales tax collection policies and other vendor marketing characteristics. Average price for each product category was then compared with marketing characteristics using linear regression for continuous variables and independent t-tests for binary variables. Our searches yielded 44 e-cigarette Internet vendors of which 77% (n = 34) sold a total of 238 starter kit offerings (Mprice = $55.89). Half (n = 22) sold disposable types of e-cigarettes (Mprice = $7.17 p/e-cigarette) at a price lower than reported elsewhere in retail settings. Average disposable e-cigarette prices were also significantly higher for vendors displaying more health warning notices (P = 0.001). Only 46% disclosed sales tax collection policies and only 39% collected sales tax in their state of business. This study expands on current understanding of e-cigarette pricing and availability online and finds variation in e-cigarette pricing may be influenced by type of product, use of online health warnings and vendor sales tax collection policies. It also finds that e-cigarette online access and availability may be impacted by a combination of pricing and marketing strategies uniquely different from e-cigarette retail settings that requires further study and targeted policy-making. [Cuomo RE, Miner A, Mackey TK. Pricing and sales tax collection policies for e-cigarette starter kits and disposable products sold online. Drug Alcohol Rev 2015]. © 2015 Australasian Professional Society on Alcohol and

  1. Presence of Streptococcus faecalis in the White Cheese Sold in Kahramanmaraş (Turkish with English Abstract)

    OpenAIRE

    Erdoğrul, Özlem Turgay; Dığak, Metin

    2014-01-01

    In this study the presence of Streptococcus faecalis in the white cheeses made from pasteurize milk sold in Kahramanmaraş were examined. For this purpose, 22 cheese samples were taken. At the end of this study, all of the samples have Streptococcus faecalis (100%). It was concluded that the examined white cheese samples were inadequate from in reads of hygienic quality by Streptococcus faecalis.

  2. Fuzzy logic control for camera tracking system

    Science.gov (United States)

    Lea, Robert N.; Fritz, R. H.; Giarratano, J.; Jani, Yashvant

    1992-01-01

    A concept utilizing fuzzy theory has been developed for a camera tracking system to provide support for proximity operations and traffic management around the Space Station Freedom. Fuzzy sets and fuzzy logic based reasoning are used in a control system which utilizes images from a camera and generates required pan and tilt commands to track and maintain a moving target in the camera's field of view. This control system can be implemented on a fuzzy chip to provide an intelligent sensor for autonomous operations. Capabilities of the control system can be expanded to include approach, handover to other sensors, caution and warning messages.

  3. A Benchmark for Virtual Camera Control

    DEFF Research Database (Denmark)

    Burelli, Paolo; Yannakakis, Georgios N.

    2015-01-01

    Automatically animating and placing the virtual camera in a dynamic environment is a challenging task. The camera is expected to maximise and maintain a set of properties — i.e. visual composition — while smoothly moving through the environment and avoiding obstacles. A large number of different....... For this reason, in this paper, we propose a benchmark for the problem of virtual camera control and we analyse a number of different problems in different virtual environments. Each of these scenarios is described through a set of complexity measures and, as a result of this analysis, a subset of scenarios...

  4. Scintillation camera with second order resolution

    International Nuclear Information System (INIS)

    Muehllehner, G.

    1976-01-01

    A scintillation camera for use in radioisotope imaging to determine the concentration of radionuclides in a two-dimensional area is described in which means is provided for second order positional resolution. The phototubes, which normally provide only a single order of resolution, are modified to provide second order positional resolution of radiation within an object positioned for viewing by the scintillation camera. The phototubes are modified in that multiple anodes are provided to receive signals from the photocathode in a manner such that each anode is particularly responsive to photoemissions from a limited portion of the photocathode. Resolution of radioactive events appearing as an output of this scintillation camera is thereby improved

  5. Smulkaus ir vidutinio verslo konkurencingumas Lietuvoje

    OpenAIRE

    Vijeikis, Juozas; Makštutis, Antanas

    2009-01-01

    Straipsnio mokslinė problema, naujumas ir aktualumas. Konkurencingumas kaip įmonių efektyvios veiklos reiškinys yra aktualus šalies verslo gyvenime vykdant darnios ekonominės plėtros politiką. Ši politika kaip problema smulkaus ir vidutinio verslo (SVV) plėtrai ir konkurencingumui didinti nėra sistemiškai ištirta ir aprašyta Lietuvos sąlygomis mokslinėje ir praktinėje literatūroje. Vienas svarbiausių veiksnių, siekiant spartaus ekonominio augimo, yra darnios verslininkystės plėtra Lietuvoje n...

  6. IR sensitivity enhancement of CMOS Image Sensor with diffractive light trapping pixels.

    Science.gov (United States)

    Yokogawa, Sozo; Oshiyama, Itaru; Ikeda, Harumi; Ebiko, Yoshiki; Hirano, Tomoyuki; Saito, Suguru; Oinoue, Takashi; Hagimoto, Yoshiya; Iwamoto, Hayato

    2017-06-19

    We report on the IR sensitivity enhancement of back-illuminated CMOS Image Sensor (BI-CIS) with 2-dimensional diffractive inverted pyramid array structure (IPA) on crystalline silicon (c-Si) and deep trench isolation (DTI). FDTD simulations of semi-infinite thick c-Si having 2D IPAs on its surface whose pitches over 400 nm shows more than 30% improvement of light absorption at λ = 850 nm and the maximum enhancement of 43% with the 540 nm pitch at the wavelength is confirmed. A prototype BI-CIS sample with pixel size of 1.2 μm square containing 400 nm pitch IPAs shows 80% sensitivity enhancement at λ = 850 nm compared to the reference sample with flat surface. This is due to diffraction with the IPA and total reflection at the pixel boundary. The NIR images taken by the demo camera equip with a C-mount lens show 75% sensitivity enhancement in the λ = 700-1200 nm wavelength range with negligible spatial resolution degradation. Light trapping CIS pixel technology promises to improve NIR sensitivity and appears to be applicable to many different image sensor applications including security camera, personal authentication, and range finding Time-of-Flight camera with IR illuminations.

  7. Household expenditures on dietary supplements sold for weight loss, muscle building, and sexual function: Disproportionate burden by gender and income.

    Science.gov (United States)

    Austin, S Bryn; Yu, Kimberly; Liu, Selena Hua; Dong, Fan; Tefft, Nathan

    2017-06-01

    Dietary supplements sold for weight loss (WL), muscle building (MB), and sexual function (SF) are not medically recommended. They have been shown to be ineffective in many cases and pose serious health risks to consumers due to adulteration with banned substances, prescription pharmaceuticals, and other dangerous chemicals. Yet no prior research has investigated how these products may disproportionately burden individuals and families by gender and socioeconomic position across households. We investigated household (HH) cost burden of dietary supplements sold for WL, MB, and SF in a cross-sectional study using data from 60,538 U.S. households (HH) in 2012 Nielsen/IRi National Consumer Panel, calculating annual HH expenditures on WL, MB, and SF supplements and expenditures as proportions of total annual HH income. We examined sociodemographic patterns in HH expenditures using Wald tests of mean differences across subgroups. Among HH with any expenditures on WL, MB, or SF supplements, annual HH first and ninth expenditure deciles were, respectively: WL $5.99, $145.36; MB $6.99, $141.93; and SF $4.98, $88.52. Conditional on any purchases of the products, female-male-headed HH spent more on WL supplements and male-headed HH spend more on MB and SF supplements compared to other HH types ( p -values supplements types ( p -values supplements ( p -values supplements sold for WL, MB, and SF disproportionately burden HH by income and gender.

  8. Advantages of computer cameras over video cameras/frame grabbers for high-speed vision applications

    Science.gov (United States)

    Olson, Gaylord G.; Walker, Jo N.

    1997-09-01

    Cameras designed to work specifically with computers can have certain advantages in comparison to the use of cameras loosely defined as 'video' cameras. In recent years the camera type distinctions have become somewhat blurred, with a great presence of 'digital cameras' aimed more at the home markets. This latter category is not considered here. The term 'computer camera' herein is intended to mean one which has low level computer (and software) control of the CCD clocking. These can often be used to satisfy some of the more demanding machine vision tasks, and in some cases with a higher rate of measurements than video cameras. Several of these specific applications are described here, including some which use recently designed CCDs which offer good combinations of parameters such as noise, speed, and resolution. Among the considerations for the choice of camera type in any given application would be such effects as 'pixel jitter,' and 'anti-aliasing.' Some of these effects may only be relevant if there is a mismatch between the number of pixels per line in the camera CCD and the number of analog to digital (A/D) sampling points along a video scan line. For the computer camera case these numbers are guaranteed to match, which alleviates some measurement inaccuracies and leads to higher effective resolution.

  9. Tarptautinio turizmo raida ir vystymo prognozės Lietuvoje ir Lenkijoje

    OpenAIRE

    Veličkaitė, Dalia

    2009-01-01

    Išanalizuota ir įvertinta Lietuvos ir Lenkijos atvykstamojo turizmo raida 2000- 2007m., užsienio turistų srautai, apgyvendinimo paslaugų paklausa, turistų tikslai ir kelionių transporto pasirinkimas, turistų išlaidos ir šalių turizmo pajamos, iškeltos atvykstamojo turizmo problemos bei pateikti jų sprendimo siūlymai.paskutinėje darbo dalyje buvo atliktos 2008- 2015metų Lietuvos ir Lenkijos turizmo raidos prognozės. In the final master work Lithuanian and Poland arriving tourism development...

  10. Camera Trajectory fromWide Baseline Images

    Science.gov (United States)

    Havlena, M.; Torii, A.; Pajdla, T.

    2008-09-01

    Camera trajectory estimation, which is closely related to the structure from motion computation, is one of the fundamental tasks in computer vision. Reliable camera trajectory estimation plays an important role in 3D reconstruction, self localization, and object recognition. There are essential issues for a reliable camera trajectory estimation, for instance, choice of the camera and its geometric projection model, camera calibration, image feature detection and description, and robust 3D structure computation. Most of approaches rely on classical perspective cameras because of the simplicity of their projection models and ease of their calibration. However, classical perspective cameras offer only a limited field of view, and thus occlusions and sharp camera turns may cause that consecutive frames look completely different when the baseline becomes longer. This makes the image feature matching very difficult (or impossible) and the camera trajectory estimation fails under such conditions. These problems can be avoided if omnidirectional cameras, e.g. a fish-eye lens convertor, are used. The hardware which we are using in practice is a combination of Nikon FC-E9 mounted via a mechanical adaptor onto a Kyocera Finecam M410R digital camera. Nikon FC-E9 is a megapixel omnidirectional addon convertor with 180° view angle which provides images of photographic quality. Kyocera Finecam M410R delivers 2272×1704 images at 3 frames per second. The resulting combination yields a circular view of diameter 1600 pixels in the image. Since consecutive frames of the omnidirectional camera often share a common region in 3D space, the image feature matching is often feasible. On the other hand, the calibration of these cameras is non-trivial and is crucial for the accuracy of the resulting 3D reconstruction. We calibrate omnidirectional cameras off-line using the state-of-the-art technique and Mičušík's two-parameter model, that links the radius of the image point r to the

  11. Lunar Reconnaissance Orbiter Camera (LROC) instrument overview

    Science.gov (United States)

    Robinson, M.S.; Brylow, S.M.; Tschimmel, M.; Humm, D.; Lawrence, S.J.; Thomas, P.C.; Denevi, B.W.; Bowman-Cisneros, E.; Zerr, J.; Ravine, M.A.; Caplinger, M.A.; Ghaemi, F.T.; Schaffner, J.A.; Malin, M.C.; Mahanti, P.; Bartels, A.; Anderson, J.; Tran, T.N.; Eliason, E.M.; McEwen, A.S.; Turtle, E.; Jolliff, B.L.; Hiesinger, H.

    2010-01-01

    The Lunar Reconnaissance Orbiter Camera (LROC) Wide Angle Camera (WAC) and Narrow Angle Cameras (NACs) are on the NASA Lunar Reconnaissance Orbiter (LRO). The WAC is a 7-color push-frame camera (100 and 400 m/pixel visible and UV, respectively), while the two NACs are monochrome narrow-angle linescan imagers (0.5 m/pixel). The primary mission of LRO is to obtain measurements of the Moon that will enable future lunar human exploration. The overarching goals of the LROC investigation include landing site identification and certification, mapping of permanently polar shadowed and sunlit regions, meter-scale mapping of polar regions, global multispectral imaging, a global morphology base map, characterization of regolith properties, and determination of current impact hazards.

  12. Gamma camera performance: technical assessment protocol

    International Nuclear Information System (INIS)

    Bolster, A.A.; Waddington, W.A.

    1996-01-01

    This protocol addresses the performance assessment of single and dual headed gamma cameras. No attempt is made to assess the performance of any associated computing systems. Evaluations are usually performed on a gamma camera commercially available within the United Kingdom and recently installed at a clinical site. In consultation with the manufacturer, GCAT selects the site and liaises with local staff to arrange a mutually convenient time for assessment. The manufacturer is encouraged to have a representative present during the evaluation. Three to four days are typically required for the evaluation team to perform the necessary measurements. When access time is limited, the team will modify the protocol to test the camera as thoroughly as possible. Data are acquired on the camera's computer system and are subsequently transferred to the independent GCAT computer system for analysis. This transfer from site computer to the independent system is effected via a hardware interface and Interfile data transfer. (author)

  13. Camera Based Navigation System with Augmented Reality

    Directory of Open Access Journals (Sweden)

    M. Marcu

    2012-06-01

    Full Text Available Nowadays smart mobile devices have enough processing power, memory, storage and always connected wireless communication bandwidth that makes them available for any type of application. Augmented reality (AR proposes a new type of applications that tries to enhance the real world by superimposing or combining virtual objects or computer generated information with it. In this paper we present a camera based navigation system with augmented reality integration. The proposed system aims to the following: the user points the camera of the smartphone towards a point of interest, like a building or any other place, and the application searches for relevant information about that specific place and superimposes the data over the video feed on the display. When the user moves the camera away, changing its orientation, the data changes as well, in real-time, with the proper information about the place that is now in the camera view.

  14. CALIBRATION PROCEDURES ON OBLIQUE CAMERA SETUPS

    Directory of Open Access Journals (Sweden)

    G. Kemper

    2016-06-01

    Full Text Available Beside the creation of virtual animated 3D City models, analysis for homeland security and city planning, the accurately determination of geometric features out of oblique imagery is an important task today. Due to the huge number of single images the reduction of control points force to make use of direct referencing devices. This causes a precise camera-calibration and additional adjustment procedures. This paper aims to show the workflow of the various calibration steps and will present examples of the calibration flight with the final 3D City model. In difference to most other software, the oblique cameras are used not as co-registered sensors in relation to the nadir one, all camera images enter the AT process as single pre-oriented data. This enables a better post calibration in order to detect variations in the single camera calibration and other mechanical effects. The shown sensor (Oblique Imager is based o 5 Phase One cameras were the nadir one has 80 MPIX equipped with a 50 mm lens while the oblique ones capture images with 50 MPix using 80 mm lenses. The cameras are mounted robust inside a housing to protect this against physical and thermal deformations. The sensor head hosts also an IMU which is connected to a POS AV GNSS Receiver. The sensor is stabilized by a gyro-mount which creates floating Antenna –IMU lever arms. They had to be registered together with the Raw GNSS-IMU Data. The camera calibration procedure was performed based on a special calibration flight with 351 shoots of all 5 cameras and registered the GPS/IMU data. This specific mission was designed in two different altitudes with additional cross lines on each flying heights. The five images from each exposure positions have no overlaps but in the block there are many overlaps resulting in up to 200 measurements per points. On each photo there were in average 110 well distributed measured points which is a satisfying number for the camera calibration. In a first

  15. Portable mini gamma camera for medical applications

    CERN Document Server

    Porras, E; Benlloch, J M; El-Djalil-Kadi-Hanifi, M; López, S; Pavon, N; Ruiz, J A; Sánchez, F; Sebastiá, A

    2002-01-01

    A small, portable and low-cost gamma camera for medical applications has been developed and clinically tested. This camera, based on a scintillator crystal and a Position Sensitive Photo-Multiplier Tube, has a useful field of view of 4.6 cm diameter and provides 2.2 mm of intrinsic spatial resolution. Its mobility and light weight allow to reach the patient from any desired direction. This camera images small organs with high efficiency and so addresses the demand for devices of specific clinical applications. In this paper, we present the camera and briefly describe the procedures that have led us to choose its configuration and the image reconstruction method. The clinical tests and diagnostic capability are also presented and discussed.

  16. Chemical Composition and Labeling of Substances Marketed as Selective Androgen Receptor Modulators and Sold via the Internet.

    Science.gov (United States)

    Van Wagoner, Ryan M; Eichner, Amy; Bhasin, Shalender; Deuster, Patricia A; Eichner, Daniel

    2017-11-28

    Recent reports have described the increasing use of nonsteroidal selective androgen receptor modulators, which have not been approved by the US Food and Drug Administration (FDA), to enhance appearance and performance. The composition and purity of such products is not known. To determine the chemical identity and the amounts of ingredients in dietary supplements and products marketed and sold through the internet as selective androgen receptor modulators and compare the analyzed contents with product labels. Web-based searches were performed from February 18, 2016, to March 25, 2016, using the Google search engine on the Chrome and Internet Explorer web browsers to identify suppliers selling selective androgen receptor modulators. The products were purchased and the identities of the compounds and their amounts were determined from April to August 2016 using chain-of-custody and World Anti-Doping Association-approved analytical procedures. Analytical findings were compared against the label information. Products marketed and sold as selective androgen receptor modulators. Chemical identities and the amount of ingredients in each product marketed and sold as selective androgen receptor modulators. Among 44 products marketed and sold as selective androgen receptor modulators, only 23 (52%) contained 1 or more selective androgen receptor modulators (Ostarine, LGD-4033, or Andarine). An additional 17 products (39%) contained another unapproved drug, including the growth hormone secretagogue ibutamoren, the peroxisome proliferator-activated receptor-δ agonist GW501516, and the Rev-ErbA agonist SR9009. Of the 44 tested products, no active compound was detected in 4 (9%) and substances not listed on the label were contained in 11 (25%). In only 18 of the 44 products (41%), the amount of active compound in the product matched that listed on the label. The amount of the compounds listed on the label differed substantially from that found by analysis in 26 of 44 products

  17. An imaging system for a gamma camera

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.

    1980-01-01

    A detailed description is given of a novel gamma camera which is designed to produce superior images than conventional cameras used in nuclear medicine. The detector consists of a solid state detector (e.g. germanium) which is formed to have a plurality of discrete components to enable 2-dimensional position identification. Details of the electronic processing circuits are given and the problems and limitations introduced by noise are discussed in full. (U.K.)

  18. Semiotic Analysis of Canon Camera Advertisements

    OpenAIRE

    INDRAWATI, SUSAN

    2015-01-01

    Keywords: Semiotic Analysis, Canon Camera, Advertisement. Advertisement is a medium to deliver message to people with the goal to influence the to use certain products. Semiotics is applied to develop a correlation within element used in an advertisement. In this study, the writer chose the Semiotic analysis of canon camera advertisement as the subject to be analyzed using semiotic study based on Peirce's theory. Semiotic approach is employed in interpreting the sign, symbol, icon, and index ...

  19. Imaging camera with multiwire proportional chamber

    International Nuclear Information System (INIS)

    Votruba, J.

    1980-01-01

    The camera for imaging radioisotope dislocations for use in nuclear medicine or for other applications, claimed in the patent, is provided by two multiwire lattices for the x-coordinate connected to a first coincidence circuit, and by two multiwire lattices for the y-coordinate connected to a second coincidence circuit. This arrangement eliminates the need of using a collimator and increases camera sensitivity while reducing production cost. (Ha)

  20. Imaging capabilities of germanium gamma cameras

    International Nuclear Information System (INIS)

    Steidley, J.W.

    1977-01-01

    Quantitative methods of analysis based on the use of a computer simulation were developed and used to investigate the imaging capabilities of germanium gamma cameras. The main advantage of the computer simulation is that the inherent unknowns of clinical imaging procedures are removed from the investigation. The effects of patient scattered radiation were incorporated using a mathematical LSF model which was empirically developed and experimentally verified. Image modifying effects of patient motion, spatial distortions, and count rate capabilities were also included in the model. Spatial domain and frequency domain modeling techniques were developed and used in the simulation as required. The imaging capabilities of gamma cameras were assessed using low contrast lesion source distributions. The results showed that an improvement in energy resolution from 10% to 2% offers significant clinical advantages in terms of improved contrast, increased detectability, and reduced patient dose. The improvements are of greatest significance for small lesions at low contrast. The results of the computer simulation were also used to compare a design of a hypothetical germanium gamma camera with a state-of-the-art scintillation camera. The computer model performed a parametric analysis of the interrelated effects of inherent and technological limitations of gamma camera imaging. In particular, the trade-off between collimator resolution and collimator efficiency for detection of a given low contrast lesion was directly addressed. This trade-off is an inherent limitation of both gamma cameras. The image degrading effects of patient motion, camera spatial distortions, and low count rate were shown to modify the improvements due to better energy resolution. Thus, based on this research, the continued development of germanium cameras to the point of clinical demonstration is recommended

  1. Compact Optical Technique for Streak Camera Calibration

    International Nuclear Information System (INIS)

    Curt Allen; Terence Davies; Frans Janson; Ronald Justin; Bruce Marshall; Oliver Sweningsen; Perry Bell; Roger Griffith; Karla Hagans; Richard Lerche

    2004-01-01

    The National Ignition Facility is under construction at the Lawrence Livermore National Laboratory for the U.S. Department of Energy Stockpile Stewardship Program. Optical streak cameras are an integral part of the experimental diagnostics instrumentation. To accurately reduce data from the streak cameras a temporal calibration is required. This article describes a technique for generating trains of precisely timed short-duration optical pulses that are suitable for temporal calibrations

  2. Review of Calibration Methods for Scheimpflug Camera

    Directory of Open Access Journals (Sweden)

    Cong Sun

    2018-01-01

    Full Text Available The Scheimpflug camera offers a wide range of applications in the field of typical close-range photogrammetry, particle image velocity, and digital image correlation due to the fact that the depth-of-view of Scheimpflug camera can be greatly extended according to the Scheimpflug condition. Yet, the conventional calibration methods are not applicable in this case because the assumptions used by classical calibration methodologies are not valid anymore for cameras undergoing Scheimpflug condition. Therefore, various methods have been investigated to solve the problem over the last few years. However, no comprehensive review exists that provides an insight into recent calibration methods of Scheimpflug cameras. This paper presents a survey of recent calibration methods of Scheimpflug cameras with perspective lens, including the general nonparametric imaging model, and analyzes in detail the advantages and drawbacks of the mainstream calibration models with respect to each other. Real data experiments including calibrations, reconstructions, and measurements are performed to assess the performance of the models. The results reveal that the accuracies of the RMM, PLVM, PCIM, and GNIM are basically equal, while the accuracy of GNIM is slightly lower compared with the other three parametric models. Moreover, the experimental results reveal that the parameters of the tangential distortion are likely coupled with the tilt angle of the sensor in Scheimpflug calibration models. The work of this paper lays the foundation of further research of Scheimpflug cameras.

  3. The Use of Camera Traps in Wildlife

    Directory of Open Access Journals (Sweden)

    Yasin Uçarlı

    2013-11-01

    Full Text Available Camera traps are increasingly used in the abundance and density estimates of wildlife species. Camera traps are very good alternative for direct observation in case, particularly, steep terrain, dense vegetation covered areas or nocturnal species. The main reason for the use of camera traps is eliminated that the economic, personnel and time loss in a continuous manner at the same time in different points. Camera traps, motion and heat sensitive, can take a photo or video according to the models. Crossover points and feeding or mating areas of the focal species are addressed as a priority camera trap set locations. The population size can be finding out by the images combined with Capture-Recapture methods. The population density came out the population size divided to effective sampling area size. Mating and breeding season, habitat choice, group structures and survival rates of the focal species can be achieved from the images. Camera traps are very useful to obtain the necessary data about the particularly mysterious species with economically in planning and conservation efforts.

  4. Towards next generation 3D cameras

    Science.gov (United States)

    Gupta, Mohit

    2017-03-01

    We are in the midst of a 3D revolution. Robots enabled by 3D cameras are beginning to autonomously drive cars, perform surgeries, and manage factories. However, when deployed in the real-world, these cameras face several challenges that prevent them from measuring 3D shape reliably. These challenges include large lighting variations (bright sunlight to dark night), presence of scattering media (fog, body tissue), and optically complex materials (metal, plastic). Due to these factors, 3D imaging is often the bottleneck in widespread adoption of several key robotics technologies. I will talk about our work on developing 3D cameras based on time-of-flight and active triangulation that addresses these long-standing problems. This includes designing `all-weather' cameras that can perform high-speed 3D scanning in harsh outdoor environments, as well as cameras that recover shape of objects with challenging material properties. These cameras are, for the first time, capable of measuring detailed (robotic inspection and assembly systems.

  5. Visualizing Infrared (IR) Spectroscopy with Computer Animation

    Science.gov (United States)

    Abrams, Charles B.; Fine, Leonard W.

    1996-01-01

    IR Tutor, an interactive, animated infrared (IR) spectroscopy tutorial has been developed for Macintosh and IBM-compatible computers. Using unique color animation, complicated vibrational modes can be introduced to beginning students. Rules governing the appearance of IR absorption bands become obvious because the vibrational modes can be visualized. Each peak in the IR spectrum is highlighted, and the animation of the corresponding normal mode can be shown. Students can study each spectrum stepwise, or click on any individual peak to see its assignment. Important regions of each spectrum can be expanded and spectra can be overlaid for comparison. An introduction to the theory of IR spectroscopy is included, making the program a complete instructional package. Our own success in using this software for teaching and research in both academic and industrial environments will be described. IR Tutor consists of three sections: (1) The 'Introduction' is a review of basic principles of spectroscopy. (2) 'Theory' begins with the classical model of a simple diatomic molecule and is expanded to include larger molecules by introducing normal modes and group frequencies. (3) 'Interpretation' is the heart of the tutorial. Thirteen IR spectra are analyzed in detail, covering the most important functional groups. This section features color animation of each normal mode, full interactivity, overlay of related spectra, and expansion of important regions. This section can also be used as a reference.

  6. Determination of selected elements in canned food sold in Jordan markets.

    Science.gov (United States)

    Massadeh, Adnan M; Al-Massaedh, Ayat Allah T; Kharibeh, Sameh

    2018-02-01

    In this study, the concentrations of seven heavy metals including As, Cd, Cr, Cu, Ni, Pb, and Zn in imported canned food samples of different brands including tuna, beef, sardines, and mushroom were determined. Samples were collected from popular Jordanian market, Irbid city, Northern Jordan (44 samples of each type). The metal concentrations in canned food samples were found to be in the range of 1.85-4.50 μg/g for As, 0.42-0.58 μg/g for Cd, 0.47-1.67 μg/g for Cr, 0.73-0.90 μg/g for Cu, 1.08-2.77 μg/g for Ni, 2.5-3.0 μg/g for Pb, and 0.43-2.25 μg/g for Zn. Results revealed that As and Pb have the highest concentrations in all samples analyzed, whereas, the lowest concentrations obtained were in Cd. For example, in canned sardine, the mean concentrations of heavy metals are 0.43 μg/g for Zn, 2.50 μg/g for Pb, 1.74 μg/g for Ni, 0.80 μg/g for Cu, 0.47 μg/g for Cr, 0.42 μg/g for Cd, and 1.85 μg/g for As. Whereas, the mean concentrations in canned tuna were 3.48 μg/g for As, 0.47 μg/g for Cd, 0.53 μg/g for Cr, 0.73 μg/g for Cu, 2.77 μg/g for Ni, 2.80 μg/g for Pb, and 1.63 μg/g for Zn. The results of this study indicated that the concentration of the tested elements including As, Cd, Cr, Ni, and Pb in canned food samples sold in Jordanian markets exceeded the permissible limits set by health organizations such as FAO/WHO. The results were compared with the literature values.

  7. Determination of some heavy metals in selected cosmetic products sold in kano metropolis, Nigeria

    Directory of Open Access Journals (Sweden)

    Ali Sani

    Full Text Available The study was aimed at assessing the levels of some toxic metals in different cosmetic products sold at different shopping malls and markets in Kano Metropolis. The cosmetic items included ten face powder, ten skin lightening creams and ten lipsticks of various prices. The cosmetics were digested and analyzed for heavy metals (manganese, nickel, copper, cadmium, chromium and lead using atomic absorption spectrophotometer. The range of the concentrations in skin lightening creams is 4.90–24.51, 3.68–11.03, 4.24–8.48, 0.14–1.32, 0–0.05 and 0.05–0.14 mg kg−1 for Mn, Ni, Cu, Cd, Cr and Pb respectively. The range in face powders are 4.90–44.12, 3.68–11.03, 4.24–8.48, 0.07–1.74, 0–0.03 and 0.08–0.33 mg kg−1 for Mn, Ni, Cu, Cd, Cr and Pb respectively. The concentration ranges in lipsticks are 2.45–22.06, 0–11.03, 4.24–12.71, 0.07–1.67, 0–0.05 and 0–0.19 mg kg−1 for Mn, Ni, Cu, Cd, Cr and Pb respectively. T test showed no statistical significant difference in concentrations of metals between the expensive and cheap cosmetic products. It is obvious from the present study that the use of these cosmetic products exposes users to low concentrations of toxic heavy metals which could constitute potential health risk to users since they are known to accumulate in biological systems over time. Similarly, regular monitoring of other heavy metals and chemicals used in the manufacture of cosmetics products which may cause health risks to users should be emphasized. Keywords: Heavy metals, Cosmetics, Concentration, Monitoring

  8. Gamma irradiation effects on tofu sold at the market in South of Jakarta region

    International Nuclear Information System (INIS)

    Idrus Kadir and Harsojo

    2009-01-01

    Tofu is one of Indonesian traditional food which is popular, well consumed and nutritious. Recent reports pointed out that some distributed tofu had low hygienic quality and contained formaline. Therefore, examination for the formaline content and hygienic quality of tofu sold either at supermarket or traditional market is needed. The purposive sampling method has been used. Samples were taken from locations determined previously. Qualitative test to observe the content of formaline and bacteria were conducted on. Tofu obtained from supermarket and traditional markets at South Jakarta which were irradiated with the dose of 3 kGy. The results showed that all of non-irradiated tofu samples observed content formaline. The total amount of aerobic bacteria in non-irradiated tofu sample were found in the range of 2.2 x 10 5 and 1.4 x 10 7 cfu/g, while for irradiated samples were in the range of 2.5 x 10 2 and 2.0 x 10 4 cfu/g. Coli form bacteria in non-irradiated tofu were in the range of 0 and 7.0 x 10 5 cfu/g, while for irradiated tofu were in the range of 2.5 x 10 2 and 2.2 x 10 3 cfu/g. Total amount of Staphylococcus for non-irradiated tofu samples were found in the range of 0 and 1.3 x 10 6 cfu/g, while for irradiated samples were in the range of 0 and 1.5 x 10 2 cfu/g. None of Salmonella was detected in all tofu samples. The pH of non-irradiated and irradiated tofu was in the range of 5.33 and 5.93, while the water content were in the range of 75.11% and 76.99%. The protein contents of non-irradiated and irradiated tofu were in the range of 7.93% and 8.83% respectively. (author)

  9. Parasitic contamination of fresh vegetables sold at central markets in Khartoum state, Sudan.

    Science.gov (United States)

    Mohamed, Mona Ali; Siddig, Emmanuel Edwar; Elaagip, Arwa Hassan; Edris, Ali Mahmoud Mohammed; Nasr, Awad Ahmed

    2016-03-11

    Fresh vegetables are considered as vital nutrients of a healthy diet as they supply the body with essential supplements. The consumption of raw vegetables is the main way for transmission of intestinal parasitic organisms. This study was aimed at detecting the parasitic contamination in fresh vegetables sold in two central open-aired markets in Khartoum state, Sudan. In this prospective cross-sectional study, a total of 260 fresh vegetable samples and 50 water samples used to sprinkle vegetable(s) were collected from two central open-aired markets (namely; Elshaabi and Central markets) during November 2011 to May 2012. The samples were microscopically examined for detection of parasitic life forms using standardized parasitological techniques for protozoans and helminthes worms. Of the 260 fresh vegetable samples, 35 (13.5 %) were microscopically positive for intestinal parasites whereas 7/50 (14 %) of water samples used to sprinkle vegetable(s) were found positives. Remarkably, high level of contamination in fresh vegetable samples was recorded in lettuce (Lactuca sativa) 36.4 % (4/11) while cayenne pepper (Capsicum annuum) and cucumber (Cucumis sativus) were not contaminated. The identified protozoans and helminthes were Entamoeba histolytica/dispar, Entamoeba coli, Giardia lamblia, Ascaris lumbricoides, Strongyloides stercoralis, T. trichiura and hookworms. The most predominant parasite encountered was E. histolytica/dispar (42.9 %) whereas both T. trichiura and A. lumbricoides (2.9 %) were the least detected parasites. None of the fresh vegetables had single parasitic contamination. The highest percentages found in water samples used to sprinkle vegetable(s) was for Strongyloides larvae 60 % (3/5). It is worth-mentioned that the rate of contamination in Elshaabi market was higher compared with Central market. However, there was no significant correlation between the type of vegetables and existence of parasites in both markets and a high significant

  10. The microbiological quality of pasteurized milk sold by automatic vending machines.

    Science.gov (United States)

    Angelidis, A S; Tsiota, S; Pexara, A; Govaris, A

    2016-06-01

    The microbiological quality of pasteurized milk samples (n = 39) collected during 13 weekly intervals from three automatic vending machines (AVM) in Greece was investigated. Microbiological counts (total aerobic (TAC), total psychrotrophic (TPC), Enterobacteriaceae (EC), and psychrotrophic aerobic bacterial spore counts (PABSC)) were obtained at the time of sampling and at the end of shelf-life (3 days) after storage of the samples at 4 or 8°C. TAC were found to be below the 10(7 ) CFU ml(-1) limit of pasteurized milk spoilage both during sampling as well as when milk samples were stored at either storage temperature for 3 days. Enterobacteriaceae populations were below 1 CFU ml(-1) in 69·2% of the samples tested at the time of sampling, whereas the remaining samples contained low numbers, typically less than 10 CFU ml(-1) . All samples tested negative for the presence of Listeria monocytogenes. Analogous microbiological data were also obtained by sampling and testing prepackaged, retail samples of pasteurized milk from two dairy companies in Greece (n = 26). From a microbiological standpoint, the data indicate that the AVM milk samples meet the quality standards of pasteurized milk. However, the prepackaged, retail milk samples yielded better results in terms of TAC, TPC and EC, compared to the AVM samples at the end of shelf-life. Recently, Greek dairy farmers organized in cooperatives launched the sale of pasteurized milk via AVM and this study reports on the microbiological quality of this product. The data show that AVM milk is sold at proper refrigeration temperatures and meets the quality standards of pasteurized milk throughout the manufacturer's specified shelf-life. However, based on the microbiological indicators tested, the keeping quality of the tested prepackaged, retail samples of pasteurized milk at the end of shelf-life upon storage under suboptimal refrigeration temperature (8°C) was better. © 2016 The Society for Applied

  11. PHYSICAL AND CHEMICAL QUALITY OF MARKET MILK SOLD AT TANDOJAM, PAKISTAN

    Directory of Open Access Journals (Sweden)

    S. B. JAVAID, J. A. GADAHI, M. KHASKELI, M. B. BHUTTO, S. KUMBHER AND A. H. PANHWAR

    2009-02-01

    Full Text Available The present study was conducted to evaluate the quality of milk sold at Tandojam, Pakistan. A total of 125 milk samples (25 samples from each source collected from five milk marketing agencies viz direct seller (DS, milk collection center(MCC, milk vendor shop (MVS, hotel (HT and buffalo dairy farm (DF, which served as control. Acidity of milk obtained from DS, MCC, MVS and HT averaged 0.13, 0.15, 0.12 and 0.13, respectively compared to 0.14 for DF milk. The pH values of milk from MVS (6.54 and HT (6.53 were significantly different (P0.05 to that of DF milk i.e. 6.65. Viscosity, specific gravity and freezing point of milk procured from DS (1.48, 1.026 and –0.460, respectively, MCC (1.58, 1.026 and –0.470, respectively, MVS (1.34, 1.026 and –0.440, respectively and HT (1.46, 1.027 and –0.480, respectively were significantly (P<0.001 lower than DF milk (1.86, 1.031 and -0.551, respectively. Chemical quality of milk procured from DS, MCC, MVS and HT compared to DF milk (control averaged 13.45, 14.18, 13.19 and 14.06% vs. 16.30% for TS content, 8.25, 8.81, 8.06 and 8.51% vs. 9.79% for SNF content, 5.20, 5.41, 5.13 and 5.54% vs. 6.51% for fat content, 3.85, 3.96, 3.91 and 4.23% vs. 4.35% for protein content, 2.70, 2.77, 2.56 and 3.20% vs. 3.56% for casein content, 3.65, 4.03, 3.34 and 3.52% vs. 4.53% for lactose content and 0.75, 0.78, 0.74 and 0.76% vs. 0.91% for ash content, respectively. All the attributes of chemical quality of milk supplied through four agencies were significantly lower (P<0.05 than DF milk.

  12. Cost of goods sold and total cost of delivery for oral and parenteral vaccine packaging formats.

    Science.gov (United States)

    Sedita, Jeff; Perrella, Stefanie; Morio, Matt; Berbari, Michael; Hsu, Jui-Shan; Saxon, Eugene; Jarrahian, Courtney; Rein-Weston, Annie; Zehrung, Darin

    2018-03-14

    Despite limitations of glass packaging for vaccines, the industry has been slow to implement alternative formats. Polymer containers may address many of these limitations, such as breakage and delamination. However, the ability of polymer containers to achieve cost of goods sold (COGS) and total cost of delivery (TCOD) competitive with that of glass containers is unclear, especially for cost-sensitive low- and lower-middle-income countries. COGS and TCOD models for oral and parenteral vaccine packaging formats were developed based on information from subject matter experts, published literature, and Kenya's comprehensive multiyear plan for immunization. Rotavirus and inactivated poliovirus vaccines (IPV) were used as representative examples of oral and parenteral vaccines, respectively. Packaging technologies evaluated included glass vials, blow-fill-seal (BFS) containers, preformed polymer containers, and compact prefilled auto-disable (CPAD) devices in both BFS and preformed formats. For oral vaccine packaging, BFS multi-monodose (MMD) ampoules were the least expensive format, with a COGS of $0.12 per dose. In comparison, oral single-dose glass vials had a COGS of $0.40. BFS MMD ampoules had the lowest TCOD of oral vaccine containers at $1.19 per dose delivered, and ten-dose glass vials had a TCOD of $1.61 per dose delivered. For parenteral vaccines, the lowest COGS was achieved with ten-dose glass vials at $0.22 per dose. In contrast, preformed CPAD devices had the highest COGS at $0.60 per dose. Ten-dose glass vials achieved the lowest TCOD of the parenteral vaccine formats at $1.56 per dose delivered. Of the polymer containers for parenteral vaccines, BFS MMD ampoules achieved the lowest TCOD at $1.89 per dose delivered, whereas preformed CPAD devices remained the most expensive format, at $2.25 per dose delivered. Given their potential to address the limitations of glass and reduce COGS and TCOD, polymer containers deserve further consideration as alternative

  13. Shutterless non-uniformity correction for the long-term stability of an uncooled long-wave infrared camera

    Science.gov (United States)

    Liu, Chengwei; Sui, Xiubao; Gu, Guohua; Chen, Qian

    2018-02-01

    For the uncooled long-wave infrared (LWIR) camera, the infrared (IR) irradiation the focal plane array (FPA) receives is a crucial factor that affects the image quality. Ambient temperature fluctuation as well as system power consumption can result in changes of FPA temperature and radiation characteristics inside the IR camera; these will further degrade the imaging performance. In this paper, we present a novel shutterless non-uniformity correction method to compensate for non-uniformity derived from the variation of ambient temperature. Our method combines a calibration-based method and the properties of a scene-based method to obtain correction parameters at different ambient temperature conditions, so that the IR camera performance can be less influenced by ambient temperature fluctuation or system power consumption. The calibration process is carried out in a temperature chamber with slowly changing ambient temperature and a black body as uniform radiation source. Enough uniform images are captured and the gain coefficients are calculated during this period. Then in practical application, the offset parameters are calculated via the least squares method based on the gain coefficients, the captured uniform images and the actual scene. Thus we can get a corrected output through the gain coefficients and offset parameters. The performance of our proposed method is evaluated on realistic IR images and compared with two existing methods. The images we used in experiments are obtained by a 384× 288 pixels uncooled LWIR camera. Results show that our proposed method can adaptively update correction parameters as the actual target scene changes and is more stable to temperature fluctuation than the other two methods.

  14. Vartotojų lojalumas : formavimas ir valdymas

    OpenAIRE

    Zikienė, Kristina

    2010-01-01

    Vienas iš esminių daugelio organizacijų tikslų, garantuojančių tolesnį sėkmingą konkuravimą nuolat besikeičiančiame verslo pasaulyje, yra vartotojų lojalumo įgijimas ir išlaikymas. Įvairios lojalumo formavimo ir valdymo problemos plačiai ir detaliai analizuojamos šioje mokomojoje knygoje. Knyga pradedama vartotojų lojalumo analize marketingo mokslo raidos kontekste. Tolesnis dėmesys skiriamas vartotojų lojalumo vadybinio aspekto analizei, atskleidžiant vartotojų lojalumo koncepcijos teorines ...

  15. The TApIR experiment. IR absorption spectra of liquid hydrogen isotopologues; Das TApIR Experiment IR-Absorptionsspektren fluessiger Wasserstoffisotopologe

    Energy Technology Data Exchange (ETDEWEB)

    Groessle, Robin

    2015-11-27

    The scope of the thesis is the infrared absorption spectroscopy of liquid hydrogen isotopologues with the tritium absorption infrared spectroscopy (TApIR) experiment at the tritium laboratory Karlsruhe (TLK). The calibration process from the sample preparation to the reference measurements are described. A further issue is the classical evaluation of FTIR absorption spectra and the extension using the rolling circle filter (RCF) including the effects on statistical and systematical errors. The impact of thermal and nuclear spin temperature on the IR absorption spectra is discussed. An empirical based modeling for the IR absorption spectra of liquid hydrogen isotopologues is performed.

  16. The Utility of Using a Near-Infrared (NIR) Camera to Measure Beach Surface Moisture

    Science.gov (United States)

    Nelson, S.; Schmutz, P. P.

    2017-12-01

    Surface moisture content is an important factor that must be considered when studying aeolian sediment transport in a beach environment. A few different instruments and procedures are available for measuring surface moisture content (i.e. moisture probes, LiDAR, and gravimetric moisture data from surface scrapings); however, these methods can be inaccurate, costly, and inapplicable, particularly in the field. Near-infrared (NIR) spectral band imagery is another technique used to obtain moisture data. NIR imagery has been predominately used through remote sensing and has yet to be used for ground-based measurements. Dry sand reflects infrared radiation given off by the sun and wet sand absorbs IR radiation. All things considered, this study assesses the utility of measuring surface moisture content of beach sand with a modified NIR camera. A traditional point and shoot digital camera was internally modified with the placement of a visible light-blocking filter. Images were taken of three different types of beach sand at controlled moisture content values, with sunlight as the source of infrared radiation. A technique was established through trial and error by comparing resultant histogram values using Adobe Photoshop with the various moisture conditions. The resultant IR absorption histogram values were calibrated to actual gravimetric moisture content from surface scrapings of the samples. Overall, the results illustrate that the NIR spectrum modified camera does not provide the ability to adequately measure beach surface moisture content. However, there were noted differences in IR absorption histogram values among the different sediment types. Sediment with darker quartz mineralogy provided larger variations in histogram values, but the technique is not sensitive enough to accurately represent low moisture percentages, which are of most importance when studying aeolian sediment transport.

  17. Test stand for non-uniformity correction of microbolometer focal plane arrays used in thermal cameras

    Science.gov (United States)

    Krupiński, Michał; Bareła, Jaroslaw; Firmanty, Krzysztof; Kastek, Mariusz

    2013-10-01

    Uneven response of particular detectors (pixels) to the same incident power of infrared radiation is an inherent feature of microbolometer focal plane arrays. As a result an image degradation occurs, known as Fixed Pattern Noise (FPN), which distorts the thermal representation of an observed scene and impairs the parameters of a thermal camera. In order to compensate such non-uniformity, several NUC correction methods are applied in digital data processing modules implemented in thermal cameras. Coefficients required to perform the non-uniformity correction procedure (NUC coefficients) are determined by calibrating the camera against uniform radiation sources (blackbodies). Non-uniformity correction is performed in a digital processing unit in order to remove FPN pattern in the registered thermal images. Relevant correction coefficients are calculated on the basis of recorded detector responses to several values of radiant flux emitted from reference IR radiation sources (blackbodies). The measurement of correction coefficients requires specialized setup, in which uniform, extended radiation sources with high temperature stability are one of key elements. Measurement stand for NUC correction developed in Institute of Optoelectronics, MUT, comprises two integrated extended blackbodies with the following specifications: area 200×200 mm, stabilized absolute temperature range +15 °C÷100 °C, and uniformity of temperature distribution across entire surface +/-0.014 °C. Test stand, method used for the measurement of NUC coefficients and the results obtained during the measurements conducted on a prototype thermal camera will be presented in the paper.

  18. Calibration Procedures in Mid Format Camera Setups

    Science.gov (United States)

    Pivnicka, F.; Kemper, G.; Geissler, S.

    2012-07-01

    A growing number of mid-format cameras are used for aerial surveying projects. To achieve a reliable and geometrically precise result also in the photogrammetric workflow, awareness on the sensitive parts is important. The use of direct referencing systems (GPS/IMU), the mounting on a stabilizing camera platform and the specific values of the mid format camera make a professional setup with various calibration and misalignment operations necessary. An important part is to have a proper camera calibration. Using aerial images over a well designed test field with 3D structures and/or different flight altitudes enable the determination of calibration values in Bingo software. It will be demonstrated how such a calibration can be performed. The direct referencing device must be mounted in a solid and reliable way to the camera. Beside the mechanical work especially in mounting the camera beside the IMU, 2 lever arms have to be measured in mm accuracy. Important are the lever arms from the GPS Antenna to the IMU's calibrated centre and also the lever arm from the IMU centre to the Camera projection centre. In fact, the measurement with a total station is not a difficult task but the definition of the right centres and the need for using rotation matrices can cause serious accuracy problems. The benefit of small and medium format cameras is that also smaller aircrafts can be used. Like that, a gyro bases stabilized platform is recommended. This causes, that the IMU must be mounted beside the camera on the stabilizer. The advantage is, that the IMU can be used to control the platform, the problematic thing is, that the IMU to GPS antenna lever arm is floating. In fact we have to deal with an additional data stream, the values of the movement of the stabiliser to correct the floating lever arm distances. If the post-processing of the GPS-IMU data by taking the floating levers into account, delivers an expected result, the lever arms between IMU and camera can be applied

  19. CALIBRATION PROCEDURES IN MID FORMAT CAMERA SETUPS

    Directory of Open Access Journals (Sweden)

    F. Pivnicka

    2012-07-01

    Full Text Available A growing number of mid-format cameras are used for aerial surveying projects. To achieve a reliable and geometrically precise result also in the photogrammetric workflow, awareness on the sensitive parts is important. The use of direct referencing systems (GPS/IMU, the mounting on a stabilizing camera platform and the specific values of the mid format camera make a professional setup with various calibration and misalignment operations necessary. An important part is to have a proper camera calibration. Using aerial images over a well designed test field with 3D structures and/or different flight altitudes enable the determination of calibration values in Bingo software. It will be demonstrated how such a calibration can be performed. The direct referencing device must be mounted in a solid and reliable way to the camera. Beside the mechanical work especially in mounting the camera beside the IMU, 2 lever arms have to be measured in mm accuracy. Important are the lever arms from the GPS Antenna to the IMU's calibrated centre and also the lever arm from the IMU centre to the Camera projection centre. In fact, the measurement with a total station is not a difficult task but the definition of the right centres and the need for using rotation matrices can cause serious accuracy problems. The benefit of small and medium format cameras is that also smaller aircrafts can be used. Like that, a gyro bases stabilized platform is recommended. This causes, that the IMU must be mounted beside the camera on the stabilizer. The advantage is, that the IMU can be used to control the platform, the problematic thing is, that the IMU to GPS antenna lever arm is floating. In fact we have to deal with an additional data stream, the values of the movement of the stabiliser to correct the floating lever arm distances. If the post-processing of the GPS-IMU data by taking the floating levers into account, delivers an expected result, the lever arms between IMU and

  20. PKCδ-mediated IRS-1 Ser24 phosphorylation negatively regulates IRS-1 function

    International Nuclear Information System (INIS)

    Greene, Michael W.; Ruhoff, Mary S.; Roth, Richard A.; Kim, Jeong-a; Quon, Michael J.; Krause, Jean A.

    2006-01-01

    The IRS-1 PH and PTB domains are essential for insulin-stimulated IRS-1 Tyr phosphorylation and insulin signaling, while Ser/Thr phosphorylation of IRS-1 disrupts these signaling events. To investigate consensus PKC phosphorylation sites in the PH-PTB domains of human IRS-1, we changed Ser24, Ser58, and Thr191 to Ala (3A) or Glu (3E), to block or mimic phosphorylation, respectively. The 3A mutant abrogated the inhibitory effect of PKCδ on insulin-stimulated IRS-1 Tyr phosphorylation, while reductions in insulin-stimulated IRS-1 Tyr phosphorylation, cellular proliferation, and Akt activation were observed with the 3E mutant. When single Glu mutants were tested, the Ser24 to Glu mutant had the greatest inhibitory effect on insulin-stimulated IRS-1 Tyr phosphorylation. PKCδ-mediated IRS-1 Ser24 phosphorylation was confirmed in cells with PKCδ catalytic domain mutants and by an RNAi method. Mechanistic studies revealed that IRS-1 with Ala and Glu point mutations at Ser24 impaired phosphatidylinositol-4,5-bisphosphate binding. In summary, our data are consistent with the hypothesis that Ser24 is a negative regulatory phosphorylation site in IRS-1

  1. Soft x-ray streak cameras

    International Nuclear Information System (INIS)

    Stradling, G.L.

    1988-01-01

    This paper is a discussion of the development and of the current state of the art in picosecond soft x-ray streak camera technology. Accomplishments from a number of institutions are discussed. X-ray streak cameras vary from standard visible streak camera designs in the use of an x-ray transmitting window and an x-ray sensitive photocathode. The spectral sensitivity range of these instruments includes portions of the near UV and extends from the subkilovolt x- ray region to several tens of kilovolts. Attendant challenges encountered in the design and use of x-ray streak cameras include the accommodation of high-voltage and vacuum requirements, as well as manipulation of a photocathode structure which is often fragile. The x-ray transmitting window is generally too fragile to withstand atmospheric pressure, necessitating active vacuum pumping and a vacuum line of sight to the x-ray signal source. Because of the difficulty of manipulating x-ray beams with conventional optics, as is done with visible light, the size of the photocathode sensing area, access to the front of the tube, the ability to insert the streak tube into a vacuum chamber and the capability to trigger the sweep with very short internal delay times are issues uniquely relevant to x-ray streak camera use. The physics of electron imaging may place more stringent limitations on the temporal and spatial resolution obtainable with x-ray photocathodes than with the visible counterpart. Other issues which are common to the entire streak camera community also concern the x-ray streak camera users and manufacturers

  2. Activity uniformity of Ir-192 seeds

    International Nuclear Information System (INIS)

    Ling, C.C.; Gromadzki, Z.C.

    1981-01-01

    A simple device that uses materials and apparatus commonly available in a radiotherapy department has been designed, fabricated and used in routine quality control relative to the activity uniformity of clinical Ir-192 seeds in ribbons. Detailed evaluation indicated that this system is easy to use and can yield relative activity measurements of individual Ir-192 seeds accurate to within 2%. With this device, activity uniformity of commercial Ir-192 seeds from two manufacturers has been assessed. For the seven shipments of Ir-192 seeds studied, the root mean square variations of individual seed strength from the average of each shipment ranged from 3.4 to 7.1%. Variation in seed activity by more than +- 10% from the average is not uncommon

  3. Implementing GPS into Pave-IR.

    Science.gov (United States)

    2009-03-01

    To further enhance the capabilities of the Pave-IR thermal segregation detection system developed at the Texas Transportation Institute, researchers incorporated global positioning system (GPS) data collection into the thermal profiles. This GPS capa...

  4. Joint IAEA/NEA IRS guidelines

    International Nuclear Information System (INIS)

    1997-01-01

    The Incident Reporting System (IRS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organization for Economic Cooperation and Development (OECD/NEA). The fundamental objective of the IRS is to contribute to improving the safety of commercial nuclear power plants (NPPs) which are operated worldwide. This objective can be achieved by providing timely and detailed information on both technical and human factors related to events of safety significance which occur at these plants. The purpose of these guidelines, which supersede the previous IAEA Safety Series No. 93 (Part II) and the NEA IRS guidelines, is to describe the system and to give users the necessary background and guidance to enable them to produce IRS reports meeting a high standard of quality while retaining the high efficiency of the system expected by all Member States operating nuclear power plants

  5. Transition-edge sensor arrays for UV-optical-IR astrophysics

    International Nuclear Information System (INIS)

    Burney, J.; Bay, T.J.; Barral, J.; Brink, P.L.; Cabrera, B.; Castle, J.P.; Miller, A.J.; Nam, S.; Rosenberg, D.; Romani, R.W.; Tomada, A.

    2006-01-01

    Our research group has developed and characterized transition-edge sensor (TES) arrays for near IR-optical-near UV astrophysical observations. These detectors have a time-stamp accuracy of 0.3μs and an energy resolution of 0.16eV for 2.33eV photons at very high rates (30kHz). We have installed a 6x6 array of these TESs in an adiabatic demagnetization refrigerator equipped with windows for direct imaging. We discuss new instrumentation progress and current data in all aspects related to successful operation of this camera system, including: detector and array performance, position dependence and cross-talk, low-temperature and readout electronics, quantum and system efficiency, IR filtering, and focus and imaging

  6. Near-IR search for lensed supernovae behind galaxy clusters. II. First detection and future prospects

    OpenAIRE

    Goobar, A.; Paech, K.; Stanishev, V.; Amanullah, R.; Dahlén, T.; Jönsson, J.; Kneib, J. P.; Lidman, C.; Limousin, M.; Mörtsell, E.; Nobili, S.; Richard, J.; Riehm, T.; von Strauss, M.

    2009-01-01

    Aims. Powerful gravitational telescopes in the form of massive galaxy clusters can be used to enhance the light collecting power over a limited field of view by about an order of magnitude in flux. This effect is exploited here to increase the depth of a survey for lensed supernovae at near-IR wavelengths. Methods. We present a pilot supernova search programme conducted with the ISAAC camera at VLT. Lensed galaxies behind the massive clusters A1689, A1835, and AC114 were observed for a tot...

  7. Quantifying biodiversity using digital cameras and automated image analysis.

    Science.gov (United States)

    Roadknight, C. M.; Rose, R. J.; Barber, M. L.; Price, M. C.; Marshall, I. W.

    2009-04-01

    Monitoring the effects on biodiversity of extensive grazing in complex semi-natural habitats is labour intensive. There are also concerns about the standardization of semi-quantitative data collection. We have chosen to focus initially on automating the most time consuming aspect - the image analysis. The advent of cheaper and more sophisticated digital camera technology has lead to a sudden increase in the number of habitat monitoring images and information that is being collected. We report on the use of automated trail cameras (designed for the game hunting market) to continuously capture images of grazer activity in a variety of habitats at Moor House National Nature Reserve, which is situated in the North of England at an average altitude of over 600m. Rainfall is high, and in most areas the soil consists of deep peat (1m to 3m), populated by a mix of heather, mosses and sedges. The cameras have been continuously in operation over a 6 month period, daylight images are in full colour and night images (IR flash) are black and white. We have developed artificial intelligence based methods to assist in the analysis of the large number of images collected, generating alert states for new or unusual image conditions. This paper describes the data collection techniques, outlines the quantitative and qualitative data collected and proposes online and offline systems that can reduce the manpower overheads and increase focus on important subsets in the collected data. By converting digital image data into statistical composite data it can be handled in a similar way to other biodiversity statistics thus improving the scalability of monitoring experiments. Unsupervised feature detection methods and supervised neural methods were tested and offered solutions to simplifying the process. Accurate (85 to 95%) categorization of faunal content can be obtained, requiring human intervention for only those images containing rare animals or unusual (undecidable) conditions, and

  8. Characterization of SWIR cameras by MRC measurements

    Science.gov (United States)

    Gerken, M.; Schlemmer, H.; Haan, Hubertus A.; Siemens, Christofer; Münzberg, M.

    2014-05-01

    Cameras for the SWIR wavelength range are becoming more and more important because of the better observation range for day-light operation under adverse weather conditions (haze, fog, rain). In order to choose the best suitable SWIR camera or to qualify a camera for a given application, characterization of the camera by means of the Minimum Resolvable Contrast MRC concept is favorable as the MRC comprises all relevant properties of the instrument. With the MRC known for a given camera device the achievable observation range can be calculated for every combination of target size, illumination level or weather conditions. MRC measurements in the SWIR wavelength band can be performed widely along the guidelines of the MRC measurements of a visual camera. Typically measurements are performed with a set of resolution targets (e.g. USAF 1951 target) manufactured with different contrast values from 50% down to less than 1%. For a given illumination level the achievable spatial resolution is then measured for each target. The resulting curve is showing the minimum contrast that is necessary to resolve the structure of a target as a function of spatial frequency. To perform MRC measurements for SWIR cameras at first the irradiation parameters have to be given in radiometric instead of photometric units which are limited in their use to the visible range. In order to do so, SWIR illumination levels for typical daylight and twilight conditions have to be defined. At second, a radiation source is necessary with appropriate emission in the SWIR range (e.g. incandescent lamp) and the irradiance has to be measured in W/m2 instead of Lux = Lumen/m2. At third, the contrast values of the targets have to be calibrated newly for the SWIR range because they typically differ from the values determined for the visual range. Measured MRC values of three cameras are compared to the specified performance data of the devices and the results of a multi-band in-house designed Vis-SWIR camera

  9. Advanced system for Gamma Cameras modernization

    International Nuclear Information System (INIS)

    Osorio Deliz, J. F.; Diaz Garcia, A.; Arista Romeu, E. J.

    2015-01-01

    Analog and digital gamma cameras still largely used in developing countries. Many of them rely in old hardware electronics, which in many cases limits their use in actual nuclear medicine diagnostic studies. Consequently, there are different worldwide companies that produce medical equipment engaged into a partial or total Gamma Cameras modernization. Present work has demonstrated the possibility of substitution of almost entire signal processing electronics placed at inside a Gamma Camera detector head by a digitizer PCI card. this card includes four 12 Bits Analog-to-Digital-Converters of 50 MHz speed. It has been installed in a PC and controlled through software developed in Lab View. Besides, there were done some changes to the hardware inside the detector head including redesign of the Orientation Display Block (ODA card). Also a new electronic design was added to the Microprocessor Control Block (MPA card) which comprised a PIC micro controller acting as a tuning system for individual Photomultiplier Tubes. The images, obtained by measurement of 99m Tc point radioactive source, using modernized camera head demonstrate its overall performance. The system was developed and tested in an old Gamma Camera ORBITER II SIEMENS GAMMASONIC at National Institute of Oncology and Radiobiology (INOR) under CAMELUD project supported by National Program PNOULU and IAEA . (Author)

  10. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  11. [Analog gamma camera digitalization computer system].

    Science.gov (United States)

    Rojas, G M; Quintana, J C; Jer, J; Astudillo, S; Arenas, L; Araya, H

    2004-01-01

    Digitalization of analogue gamma cameras systems, using special acquisition boards in microcomputers and appropriate software for acquisition and processing of nuclear medicine images is described in detail. Microcomputer integrated systems interconnected by means of a Local Area Network (LAN) and connected to several gamma cameras have been implemented using specialized acquisition boards. The PIP software (Portable Image Processing) was installed on each microcomputer to acquire and preprocess the nuclear medicine images. A specialized image processing software has been designed and developed for these purposes. This software allows processing of each nuclear medicine exam, in a semiautomatic procedure, and recording of the results on radiological films. . A stable, flexible and inexpensive system which makes it possible to digitize, visualize, process, and print nuclear medicine images obtained from analogue gamma cameras was implemented in the Nuclear Medicine Division. Such a system yields higher quality images than those obtained with analogue cameras while keeping operating costs considerably lower (filming: 24.6%, fixing 48.2% and developing 26%.) Analogue gamma camera systems can be digitalized economically. This system makes it possible to obtain optimal clinical quality nuclear medicine images, to increase the acquisition and processing efficiency, and to reduce the steps involved in each exam.

  12. A wide field X-ray camera

    International Nuclear Information System (INIS)

    Sims, M.; Turner, M.J.L.; Willingale, R.

    1980-01-01

    A wide field of view X-ray camera based on the Dicke or Coded Mask principle is described. It is shown that this type of instrument is more sensitive than a pin-hole camera, or than a scanning survey of a given region of sky for all wide field conditions. The design of a practical camera is discussed and the sensitivity and performance of the chosen design are evaluated by means of computer simulations. The Wiener Filter and Maximum Entropy methods of deconvolution are described and these methods are compared with each other and cross-correlation using data from the computer simulations. It is shown that the analytic expressions for sensitivity used by other workers are confirmed by the simulations, and that ghost images caused by incomplete coding can be substantially eliminated by the use of the Wiener Filter and the Maximum Entropy Method, with some penalty in computer time for the latter. The cyclic mask configuration is compared with the simple mask camera. It is shown that when the diffuse X-ray background dominates, the simple system is more sensitive and has the better angular resolution. When sources dominate the simple system is less sensitive. It is concluded that the simple coded mask camera is the best instrument for wide field imaging of the X-ray sky. (orig.)

  13. Calibration of action cameras for photogrammetric purposes.

    Science.gov (United States)

    Balletti, Caterina; Guerra, Francesco; Tsioukas, Vassilios; Vernier, Paolo

    2014-09-18

    The use of action cameras for photogrammetry purposes is not widespread due to the fact that until recently the images provided by the sensors, using either still or video capture mode, were not big enough to perform and provide the appropriate analysis with the necessary photogrammetric accuracy. However, several manufacturers have recently produced and released new lightweight devices which are: (a) easy to handle, (b) capable of performing under extreme conditions and more importantly (c) able to provide both still images and video sequences of high resolution. In order to be able to use the sensor of action cameras we must apply a careful and reliable self-calibration prior to the use of any photogrammetric procedure, a relatively difficult scenario because of the short focal length of the camera and its wide angle lens that is used to obtain the maximum possible resolution of images. Special software, using functions of the OpenCV library, has been created to perform both the calibration and the production of undistorted scenes for each one of the still and video image capturing mode of a novel action camera, the GoPro Hero 3 camera that can provide still images up to 12 Mp and video up 8 Mp resolution.

  14. Calibration of Action Cameras for Photogrammetric Purposes

    Directory of Open Access Journals (Sweden)

    Caterina Balletti

    2014-09-01

    Full Text Available The use of action cameras for photogrammetry purposes is not widespread due to the fact that until recently the images provided by the sensors, using either still or video capture mode, were not big enough to perform and provide the appropriate analysis with the necessary photogrammetric accuracy. However, several manufacturers have recently produced and released new lightweight devices which are: (a easy to handle, (b capable of performing under extreme conditions and more importantly (c able to provide both still images and video sequences of high resolution. In order to be able to use the sensor of action cameras we must apply a careful and reliable self-calibration prior to the use of any photogrammetric procedure, a relatively difficult scenario because of the short focal length of the camera and its wide angle lens that is used to obtain the maximum possible resolution of images. Special software, using functions of the OpenCV library, has been created to perform both the calibration and the production of undistorted scenes for each one of the still and video image capturing mode of a novel action camera, the GoPro Hero 3 camera that can provide still images up to 12 Mp and video up 8 Mp resolution.

  15. Wired and Wireless Camera Triggering with Arduino

    Science.gov (United States)

    Kauhanen, H.; Rönnholm, P.

    2017-10-01

    Synchronous triggering is an important task that allows simultaneous data capture from multiple cameras. Accurate synchronization enables 3D measurements of moving objects or from a moving platform. In this paper, we describe one wired and four wireless variations of Arduino-based low-cost remote trigger systems designed to provide a synchronous trigger signal for industrial cameras. Our wireless systems utilize 315 MHz or 434 MHz frequencies with noise filtering capacitors. In order to validate the synchronization accuracy, we developed a prototype of a rotating trigger detection system (named RoTriDeS). This system is suitable to detect the triggering accuracy of global shutter cameras. As a result, the wired system indicated an 8.91 μs mean triggering time difference between two cameras. Corresponding mean values for the four wireless triggering systems varied between 7.92 and 9.42 μs. Presented values include both camera-based and trigger-based desynchronization. Arduino-based triggering systems appeared to be feasible, and they have the potential to be extended to more complicated triggering systems.

  16. Gamma cameras - a method of evaluation

    International Nuclear Information System (INIS)

    Oates, L.; Bibbo, G.

    2000-01-01

    Full text: With the sophistication and longevity of the modern gamma camera it is not often that the need arises to evaluate a gamma camera for purchase. We have recently been placed in the position of retiring our two single headed cameras of some vintage and replacing them with a state of the art dual head variable angle gamma camera. The process used for the evaluation consisted of five parts: (1) Evaluation of the technical specification as expressed in the tender document; (2) A questionnaire adapted from the British Society of Nuclear Medicine; (3) Site visits to assess gantry configuration, movement, patient access and occupational health, welfare and safety considerations; (4) Evaluation of the processing systems offered; (5) Whole of life costing based on equally configured systems. The results of each part of the evaluation were expressed using a weighted matrix analysis with each of the criteria assessed being weighted in accordance with their importance to the provision of an effective nuclear medicine service for our centre and the particular importance to paediatric nuclear medicine. This analysis provided an objective assessment of each gamma camera system from which a purchase recommendation was made. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. Computer vision camera with embedded FPGA processing

    Science.gov (United States)

    Lecerf, Antoine; Ouellet, Denis; Arias-Estrada, Miguel

    2000-03-01

    Traditional computer vision is based on a camera-computer system in which the image understanding algorithms are embedded in the computer. To circumvent the computational load of vision algorithms, low-level processing and imaging hardware can be integrated in a single compact module where a dedicated architecture is implemented. This paper presents a Computer Vision Camera based on an open architecture implemented in an FPGA. The system is targeted to real-time computer vision tasks where low level processing and feature extraction tasks can be implemented in the FPGA device. The camera integrates a CMOS image sensor, an FPGA device, two memory banks, and an embedded PC for communication and control tasks. The FPGA device is a medium size one equivalent to 25,000 logic gates. The device is connected to two high speed memory banks, an IS interface, and an imager interface. The camera can be accessed for architecture programming, data transfer, and control through an Ethernet link from a remote computer. A hardware architecture can be defined in a Hardware Description Language (like VHDL), simulated and synthesized into digital structures that can be programmed into the FPGA and tested on the camera. The architecture of a classical multi-scale edge detection algorithm based on a Laplacian of Gaussian convolution has been developed to show the capabilities of the system.

  18. Designing Camera Networks by Convex Quadratic Programming

    KAUST Repository

    Ghanem, Bernard

    2015-05-04

    ​In this paper, we study the problem of automatic camera placement for computer graphics and computer vision applications. We extend the problem formulations of previous work by proposing a novel way to incorporate visibility constraints and camera-to-camera relationships. For example, the placement solution can be encouraged to have cameras that image the same important locations from different viewing directions, which can enable reconstruction and surveillance tasks to perform better. We show that the general camera placement problem can be formulated mathematically as a convex binary quadratic program (BQP) under linear constraints. Moreover, we propose an optimization strategy with a favorable trade-off between speed and solution quality. Our solution is almost as fast as a greedy treatment of the problem, but the quality is significantly higher, so much so that it is comparable to exact solutions that take orders of magnitude more computation time. Because it is computationally attractive, our method also allows users to explore the space of solutions for variations in input parameters. To evaluate its effectiveness, we show a range of 3D results on real-world floorplans (garage, hotel, mall, and airport). ​

  19. Hidden cameras everything you need to know about covert recording, undercover cameras and secret filming

    CERN Document Server

    Plomin, Joe

    2016-01-01

    Providing authoritative information on the practicalities of using hidden cameras to expose abuse or wrongdoing, this book is vital reading for anyone who may use or encounter secret filming. It gives specific advice on using phones or covert cameras and unravels the complex legal and ethical issues that need to be considered.

  20. Mobile phone camera benchmarking: combination of camera speed and image quality

    Science.gov (United States)

    Peltoketo, Veli-Tapani

    2014-01-01

    When a mobile phone camera is tested and benchmarked, the significance of quality metrics is widely acknowledged. There are also existing methods to evaluate the camera speed. For example, ISO 15781 defines several measurements to evaluate various camera system delays. However, the speed or rapidity metrics of the mobile phone's camera system have not been used with the quality metrics even if the camera speed has become more and more important camera performance feature. There are several tasks in this work. Firstly, the most important image quality metrics are collected from the standards and papers. Secondly, the speed related metrics of a mobile phone's camera system are collected from the standards and papers and also novel speed metrics are identified. Thirdly, combinations of the quality and speed metrics are validated using mobile phones in the market. The measurements are done towards application programming interface of different operating system. Finally, the results are evaluated and conclusions are made. The result of this work gives detailed benchmarking results of mobile phone camera systems in the market. The paper defines also a proposal of combined benchmarking metrics, which includes both quality and speed parameters.

  1. The eye of the camera: effects of security cameras on pro-social behavior

    NARCIS (Netherlands)

    van Rompay, T.J.L.; Vonk, D.J.; Fransen, M.L.

    2009-01-01

    This study addresses the effects of security cameras on prosocial behavior. Results from previous studies indicate that the presence of others can trigger helping behavior, arising from the need for approval of others. Extending these findings, the authors propose that security cameras can likewise

  2. Trace elements in rock phosphates and P containing mineral and organo-mineral fertilizers sold in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Kratz, Sylvia, E-mail: sylvia.kratz@jki.bund.de; Schick, Judith; Schnug, Ewald

    2016-01-15

    68 rock phosphates and 162 P containing (organo-)mineral fertilizers sold in Germany were evaluated with regard to trace element contents. While Al, As, B, Be, Cd, Cr, Mo, Ni, Pb, Sb, Se, Tl, U, and Zn were higher in sedimentary than in igneous rock phosphates, the opposite was true for Co, Cu, Sn, Mn, Ti, Fe, and Sr. Comparing element concentrations to the currently valid legal limit values defined by the German Fertilizer Ordinance, it was found that some PK and many straight P fertilizers (superphosphate, triple superphosphate, partly acidulated rock phosphates) exceeded the limit of 50 mg Cd/kg P{sub 2}O{sub 5}. Mean values for As, Ni, Pb, and Tl remained below legal limits in almost all cases. While no legal limit has been defined for U in Germany yet, the limit of 50 mg U/kg P{sub 2}O{sub 5} for P containing fertilizers proposed by the German Commission for the Protection of Soils was clearly exceeded by mean values for all fertilizer types analyzed. A large share of the samples evaluated in this work contained essential trace elements at high concentrations, with many of them not being declared as such. Furthermore, trace elements supplied with these fertilizers at a fertilization rate leveling P uptake would exceed trace element uptake by crops. This may become most relevant for B and Fe, since many crops are sensitive to an oversupply of B, and Fe loads exceeding plant uptake may immobilize P supplies for the crops by forming Fe phosphate salts. The sample set included two products made from thermochemically treated sewage sludge ash. The products displayed very high concentrations of Fe and Mn and exceeded the legal limit for Ni, emphasizing the necessity to continue research on heavy metal removal from recycled raw materials and the development of environmentally friendly and agriculturally efficient fertilizer products. - Highlights: • Mineral fertilizers (MF) sold in Germany often exceed legal limits for Cd • MF sold in Germany contain high

  3. The development of large-aperture test system of infrared camera and visible CCD camera

    Science.gov (United States)

    Li, Yingwen; Geng, Anbing; Wang, Bo; Wang, Haitao; Wu, Yanying

    2015-10-01

    Infrared camera and CCD camera dual-band imaging system is used in many equipment and application widely. If it is tested using the traditional infrared camera test system and visible CCD test system, 2 times of installation and alignment are needed in the test procedure. The large-aperture test system of infrared camera and visible CCD camera uses the common large-aperture reflection collimator, target wheel, frame-grabber, computer which reduces the cost and the time of installation and alignment. Multiple-frame averaging algorithm is used to reduce the influence of random noise. Athermal optical design is adopted to reduce the change of focal length location change of collimator when the environmental temperature is changing, and the image quality of the collimator of large field of view and test accuracy are also improved. Its performance is the same as that of the exotic congener and is much cheaper. It will have a good market.

  4. VUV testing of science cameras at MSFC: QE measurement of the CLASP flight cameras

    Science.gov (United States)

    Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, B.; Beabout, D.; Stewart, M.

    2015-08-01

    The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint MSFC, National Astronomical Observatory of Japan (NAOJ), Instituto de Astrofisica de Canarias (IAC) and Institut D'Astrophysique Spatiale (IAS) sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512 × 512 detector, dual channel analog readout and an internally mounted cold block. At the flight CCD temperature of -20C, the CLASP cameras exceeded the low-noise performance requirements (UV, EUV and X-ray science cameras at MSFC.

  5. Acceptance/Operational Test Report for Tank 241-AN-104 camera and camera purge control system

    International Nuclear Information System (INIS)

    Castleberry, J.L.

    1995-11-01

    This Acceptance/Operational Test Procedure (ATP/OTP) will document the satisfactory operation of the camera purge panel, purge control panel, color camera system and associated control components destined for installation. The final acceptance of the complete system will be performed in the field. The purge panel and purge control panel will be tested for its safety interlock which shuts down the camera and pan-and-tilt inside the tank vapor space during loss of purge pressure and that the correct purge volume exchanges are performed as required by NFPA 496. This procedure is separated into seven sections. This Acceptance/Operational Test Report documents the successful acceptance and operability testing of the 241-AN-104 camera system and camera purge control system

  6. SENSITIVITY TEMPERATURE DEPENDENCE RESEARCH OF TV-CAMERAS BASED ON SILICON MATRIXES

    Directory of Open Access Journals (Sweden)

    Alexey N. Starchenko

    2017-07-01

    Full Text Available Subject of Research. The research is dedicated to the analysis of sensitivity change patterns of the cameras based on silicon CMOS-matrixes in various ambient temperatures. This information is necessary for the correct camera application for photometric measurements in-situ. The paper deals with studies of sensitivity variations of two digital cameras with different silicon CMOS matrixes in visible and near IR regions of the spectrum at temperature change. Method. Due to practical restrictions the temperature changes were recorded in separate spectral intervals important for practical use of the cameras. The experiments were carried out with the use of a climatic chamber, providing change and keeping the temperature range from minus 40 to plus 50 °C at a pitch of 10 о С. Two cameras were chosen for research: VAC-135-IP with OmniVision OV9121 matrix and VAC-248-IP with OnSemiconductor VITA2000 matrix. The two tested devices were placed in a climatic chamber at the same time and illuminated by one radiation source with a color temperature about 3000 K in order to eliminate a number of methodological errors. Main Results. The temperature dependence of the signals was shown to be linear and the matrixes sensitivities were determined. The results obtained are consistent with theoretical views, in general. The coefficients of thermal sensitivity were computed by these dependencies. It is shown that the greatest affect of temperature on the sensitivity occurs in the area (0.7–1.1 mkm. Temperature coefficients of sensitivity increase with the downward radiation wavelength increase. The experiments carried out have shown that it is necessary to take into account the changes in temperature sensitivity of silicon matrixes in the red and near in IR regions of the spectrum. The effect reveals itself in a clearly negative way in cameras with an amplitude resolution of 10-12 bits used for aerospace and space spectrozonal photography. Practical Relevance

  7. Multi-view collimators for scintillation cameras

    International Nuclear Information System (INIS)

    Hatton, J.; Grenier, R.P.

    1982-01-01

    This patent specification describes a collimator for obtaining multiple images of a portion of a body with a scintillation camera comprises a body of radiation-impervious material defining two or more groups of channels each group comprising a plurality of parallel channels having axes intersecting the portion of the body being viewed on one side of the collimator and intersecting the input surface of the camera on the other side of the collimator to produce a single view of said body, a number of different such views of said body being provided by each of said groups of channels, each axis of each channel lying in a plane approximately perpendicular to the plane of the input surface of the camera and all of such planes containing said axes being approximately parallel to each other. (author)

  8. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The objects of this invention are first to reduce the time required to obtain statistically significant data in trans-axial tomographic radioisotope scanning using a scintillation camera. Secondly, to provide a scintillation camera system to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a known radiation source without sacrificing spatial resolution. Thirdly to reduce the scanning time without loss of image clarity. The system described comprises a scintillation camera detector, means for moving this in orbit about a cranial-caudal axis relative to a patient and a collimator having septa defining apertures such that gamma rays perpendicular to the axis are admitted with high spatial resolution, parallel to the axis with low resolution. The septa may be made of strips of lead. Detailed descriptions are given. (U.K.)

  9. Gate Simulation of a Gamma Camera

    International Nuclear Information System (INIS)

    Abidi, Sana; Mlaouhi, Zohra

    2008-01-01

    Medical imaging is a very important diagnostic because it allows for an exploration of the internal human body. The nuclear imaging is an imaging technique used in the nuclear medicine. It is to determine the distribution in the body of a radiotracers by detecting the radiation it emits using a detection device. Two methods are commonly used: Single Photon Emission Computed Tomography (SPECT) and the Positrons Emission Tomography (PET). In this work we are interested on modelling of a gamma camera. This simulation is based on Monte-Carlo language and in particular Gate simulator (Geant4 Application Tomographic Emission). We have simulated a clinical gamma camera called GAEDE (GKS-1) and then we validate these simulations by experiments. The purpose of this work is to monitor the performance of these gamma camera and the optimization of the detector performance and the the improvement of the images quality. (Author)

  10. Ultra-fast framing camera tube

    Science.gov (United States)

    Kalibjian, Ralph

    1981-01-01

    An electronic framing camera tube features focal plane image dissection and synchronized restoration of the dissected electron line images to form two-dimensional framed images. Ultra-fast framing is performed by first streaking a two-dimensional electron image across a narrow slit, thereby dissecting the two-dimensional electron image into sequential electron line images. The dissected electron line images are then restored into a framed image by a restorer deflector operated synchronously with the dissector deflector. The number of framed images on the tube's viewing screen is equal to the number of dissecting slits in the tube. The distinguishing features of this ultra-fast framing camera tube are the focal plane dissecting slits, and the synchronously-operated restorer deflector which restores the dissected electron line images into a two-dimensional framed image. The framing camera tube can produce image frames having high spatial resolution of optical events in the sub-100 picosecond range.

  11. Camera systems for crash and hyge testing

    Science.gov (United States)

    Schreppers, Frederik

    1995-05-01

    Since the beginning of the use of high speed cameras for crash and hyge- testing substantial changements have taken place. Both the high speed cameras and the electronic control equipment are more sophisticated nowadays. With regard to high speed equipment, a short historical retrospective view will show that concerning high speed cameras, the improvements are mainly concentrated in design details, where as the electronic control equipment has taken full advantage of the rapid progress in electronic and computer technology in the course of the last decades. Nowadays many companies and institutes involved in crash and hyge-testing wish to perform this testing, as far as possible, as an automatic computer controlled routine in order to maintain and improve security and quality. By means of several in practice realize solutions, it will be shown how their requirements could be met.

  12. Mechanical Design of the LSST Camera

    Energy Technology Data Exchange (ETDEWEB)

    Nordby, Martin; Bowden, Gordon; Foss, Mike; Guiffre, Gary; /SLAC; Ku, John; /Unlisted; Schindler, Rafe; /SLAC

    2008-06-13

    The LSST camera is a tightly packaged, hermetically-sealed system that is cantilevered into the main beam of the LSST telescope. It is comprised of three refractive lenses, on-board storage for five large filters, a high-precision shutter, and a cryostat that houses the 3.2 giga-pixel CCD focal plane along with its support electronics. The physically large optics and focal plane demand large structural elements to support them, but the overall size of the camera and its components must be minimized to reduce impact on the image stability. Also, focal plane and optics motions must be minimized to reduce systematic errors in image reconstruction. Design and analysis for the camera body and cryostat will be detailed.

  13. Temperature measurement with industrial color camera devices

    Science.gov (United States)

    Schmidradler, Dieter J.; Berndorfer, Thomas; van Dyck, Walter; Pretschuh, Juergen

    1999-05-01

    This paper discusses color camera based temperature measurement. Usually, visual imaging and infrared image sensing are treated as two separate disciplines. We will show, that a well selected color camera device might be a cheaper, more robust and more sophisticated solution for optical temperature measurement in several cases. Herein, only implementation fragments and important restrictions for the sensing element will be discussed. Our aim is to draw the readers attention to the use of visual image sensors for measuring thermal radiation and temperature and to give reasons for the need of improved technologies for infrared camera devices. With AVL-List, our partner of industry, we successfully used the proposed sensor to perform temperature measurement for flames inside the combustion chamber of diesel engines which finally led to the presented insights.

  14. Scintillation camera with second order resolution

    International Nuclear Information System (INIS)

    1975-01-01

    A scintillation camera is described for use in radioisotope imaging to determine the concentration of radionuclides in a two-dimensional area in which means is provided for second-order positional resolution. The phototubes which normally provide only a single order of resolution, are modified to provide second-order positional resolution of radiation within an object positioned for viewing by the scintillation camera. The phototubes are modified in that multiple anodes are provided to receive signals from the photocathode in a manner such that each anode is particularly responsive to photoemissions from a limited portion of the photocathode. Resolution of radioactive events appearing as an output of this scintillation camera is thereby improved

  15. PEOPLE REIDENTIFCATION IN A DISTRIBUTED CAMERA NETWORK

    Directory of Open Access Journals (Sweden)

    Icaro Oliveira de Oliveira

    2010-06-01

    Full Text Available This paper presents an approach to the object reidentification problem in a distributed camera network system. The reidentification or reacquisition problem consists essentially on the matching process of images acquired from different cameras. This work is applied in a monitored environment by cameras. This application is important to modern security systems, in which the targets presence identification in the environment expands the capacity of action by security agents in real time and provides important parameters like localization for each target. We used target’s interest points and target’s color with features for reidentification. The satisfactory results were obtained from real experiments in public video datasets and synthetic images with noise.

  16. Video Sharing System Based on Wi-Fi Camera

    OpenAIRE

    Qidi Lin; Hewei Yu; Jinbin Huang; Weile Liang

    2015-01-01

    This paper introduces a video sharing platform based on WiFi, which consists of camera, mobile phone and PC server. This platform can receive wireless signal from the camera and show the live video on the mobile phone captured by camera. In addition, it is able to send commands to camera and control the camera's holder to rotate. The platform can be applied to interactive teaching and dangerous area's monitoring and so on. Testing results show that the platform can share ...

  17. Optimum color filters for CCD digital cameras

    Science.gov (United States)

    Engelhardt, Kai; Kunz, Rino E.; Seitz, Peter; Brunner, Harald; Knop, Karl

    1993-12-01

    As part of the ESPRIT II project No. 2103 (MASCOT) a high performance prototype color CCD still video camera was developed. Intended for professional usage such as in the graphic arts, the camera provides a maximum resolution of 3k X 3k full color pixels. A high colorimetric performance was achieved through specially designed dielectric filters and optimized matrixing. The color transformation was obtained by computer simulation of the camera system and non-linear optimization which minimized the perceivable color errors as measured in the 1976 CIELUV uniform color space for a set of about 200 carefully selected test colors. The color filters were designed to allow perfect colorimetric reproduction in principle and at the same time with imperceptible color noise and with special attention to fabrication tolerances. The camera system includes a special real-time digital color processor which carries out the color transformation. The transformation can be selected from a set of sixteen matrices optimized for different illuminants and output devices. Because the actual filter design was based on slightly incorrect data the prototype camera showed a mean colorimetric error of 2.7 j.n.d. (CIELUV) in experiments. Using correct input data in the redesign of the filters, a mean colorimetric error of only 1 j.n.d. (CIELUV) seems to be feasible, implying that it is possible with such an optimized color camera to achieve such a high colorimetric performance that the reproduced colors in an image cannot be distinguished from the original colors in a scene, even in direct comparison.

  18. Phase camera experiment for Advanced Virgo

    Energy Technology Data Exchange (ETDEWEB)

    Agatsuma, Kazuhiro, E-mail: agatsuma@nikhef.nl [National Institute for Subatomic Physics, Amsterdam (Netherlands); Beuzekom, Martin van; Schaaf, Laura van der [National Institute for Subatomic Physics, Amsterdam (Netherlands); Brand, Jo van den [National Institute for Subatomic Physics, Amsterdam (Netherlands); VU University, Amsterdam (Netherlands)

    2016-07-11

    We report on a study of the phase camera, which is a frequency selective wave-front sensor of a laser beam. This sensor is utilized for monitoring sidebands produced by phase modulations in a gravitational wave (GW) detector. Regarding the operation of the GW detectors, the laser modulation/demodulation method is used to measure mirror displacements and used for the position controls. This plays a significant role because the quality of controls affect the noise level of the GW detector. The phase camera is able to monitor each sideband separately, which has a great benefit for the manipulation of the delicate controls. Also, overcoming mirror aberrations will be an essential part of Advanced Virgo (AdV), which is a GW detector close to Pisa. Especially low-frequency sidebands can be affected greatly by aberrations in one of the interferometer cavities. The phase cameras allow tracking such changes because the state of the sidebands gives information on mirror aberrations. A prototype of the phase camera has been developed and is currently tested. The performance checks are almost completed and the installation of the optics at the AdV site has started. After the installation and commissioning, the phase camera will be combined to a thermal compensation system that consists of CO{sub 2} lasers and compensation plates. In this paper, we focus on the prototype and show some limitations from the scanner performance. - Highlights: • The phase camera is being developed for a gravitational wave detector. • A scanner performance limits the operation speed and layout design of the system. • An operation range was found by measuring the frequency response of the scanner.

  19. Phase camera experiment for Advanced Virgo

    International Nuclear Information System (INIS)

    Agatsuma, Kazuhiro; Beuzekom, Martin van; Schaaf, Laura van der; Brand, Jo van den

    2016-01-01

    We report on a study of the phase camera, which is a frequency selective wave-front sensor of a laser beam. This sensor is utilized for monitoring sidebands produced by phase modulations in a gravitational wave (GW) detector. Regarding the operation of the GW detectors, the laser modulation/demodulation method is used to measure mirror displacements and used for the position controls. This plays a significant role because the quality of controls affect the noise level of the GW detector. The phase camera is able to monitor each sideband separately, which has a great benefit for the manipulation of the delicate controls. Also, overcoming mirror aberrations will be an essential part of Advanced Virgo (AdV), which is a GW detector close to Pisa. Especially low-frequency sidebands can be affected greatly by aberrations in one of the interferometer cavities. The phase cameras allow tracking such changes because the state of the sidebands gives information on mirror aberrations. A prototype of the phase camera has been developed and is currently tested. The performance checks are almost completed and the installation of the optics at the AdV site has started. After the installation and commissioning, the phase camera will be combined to a thermal compensation system that consists of CO 2 lasers and compensation plates. In this paper, we focus on the prototype and show some limitations from the scanner performance. - Highlights: • The phase camera is being developed for a gravitational wave detector. • A scanner performance limits the operation speed and layout design of the system. • An operation range was found by measuring the frequency response of the scanner.

  20. Small Orbital Stereo Tracking Camera Technology Development

    Science.gov (United States)

    Gagliano, L.; Bryan, T.; MacLeod, T.

    On-Orbit Small Debris Tracking and Characterization is a technical gap in the current National Space Situational Awareness necessary to safeguard orbital assets and crew. This poses a major risk of MOD damage to ISS and Exploration vehicles. In 2015 this technology was added to NASAs Office of Chief Technologist roadmap. For missions flying in or assembled in or staging from LEO, the physical threat to vehicle and crew is needed in order to properly design the proper level of MOD impact shielding and proper mission design restrictions. Need to verify debris flux and size population versus ground RADAR tracking. Use of ISS for In-Situ Orbital Debris Tracking development provides attitude, power, data and orbital access without a dedicated spacecraft or restricted operations on-board a host vehicle as a secondary payload. Sensor Applicable to in-situ measuring orbital debris in flux and population in other orbits or on other vehicles. Could enhance safety on and around ISS. Some technologies extensible to monitoring of extraterrestrial debris as well To help accomplish this, new technologies must be developed quickly. The Small Orbital Stereo Tracking Camera is one such up and coming technology. It consists of flying a pair of intensified megapixel telephoto cameras to evaluate Orbital Debris (OD) monitoring in proximity of International Space Station. It will demonstrate on-orbit optical tracking (in situ) of various sized objects versus ground RADAR tracking and small OD models. The cameras are based on Flight Proven Advanced Video Guidance Sensor pixel to spot algorithms (Orbital Express) and military targeting cameras. And by using twin cameras we can provide Stereo images for ranging & mission redundancy. When pointed into the orbital velocity vector (RAM), objects approaching or near the stereo camera set can be differentiated from the stars moving upward in background.

  1. Performance assessment of gamma cameras. Part 1

    International Nuclear Information System (INIS)

    Elliot, A.T.; Short, M.D.; Potter, D.C.; Barnes, K.J.

    1980-11-01

    The Dept. of Health and Social Security and the Scottish Home and Health Dept. has sponsored a programme of measurements of the important performance characteristics of 15 leading types of gamma cameras providing a routine radionuclide imaging service in hospitals throughout the UK. Measurements have been made of intrinsic resolution, system resolution, non-uniformity, spatial distortion, count rate performance, sensitivity, energy resolution and shield leakage. The main aim of this performance assessment was to provide sound information to the NHS to ease the task of those responsible for the purchase of gamma cameras. (U.K.)

  2. Analysis of Brown camera distortion model

    Science.gov (United States)

    Nowakowski, Artur; Skarbek, Władysław

    2013-10-01

    Contemporary image acquisition devices introduce optical distortion into image. It results in pixel displacement and therefore needs to be compensated for many computer vision applications. The distortion is usually modeled by the Brown distortion model, which parameters can be included in camera calibration task. In this paper we describe original model, its dependencies and analyze orthogonality with regard to radius for its decentering distortion component. We also report experiments with camera calibration algorithm included in OpenCV library, especially a stability of distortion parameters estimation is evaluated.

  3. Camera-enabled techniques for organic synthesis

    Directory of Open Access Journals (Sweden)

    Steven V. Ley

    2013-05-01

    Full Text Available A great deal of time is spent within synthetic chemistry laboratories on non-value-adding activities such as sample preparation and work-up operations, and labour intensive activities such as extended periods of continued data collection. Using digital cameras connected to computer vision algorithms, camera-enabled apparatus can perform some of these processes in an automated fashion, allowing skilled chemists to spend their time more productively. In this review we describe recent advances in this field of chemical synthesis and discuss how they will lead to advanced synthesis laboratories of the future.

  4. A holographic color camera for recording artifacts

    International Nuclear Information System (INIS)

    Jith, Abhay

    2013-01-01

    Advent of 3D televisions has created a new wave of public interest in images with depth. Though these technologies create moving pictures with apparent depth, it lacks the visual appeal and a set of other positive aspects of color holographic images. The above new wave of interest in 3D will definitely help to fuel popularity of holograms. In view of this, a low cost and handy color holography camera is designed for recording color holograms of artifacts. It is believed that such cameras will help to record medium format color holograms outside conventional holography laboratories and to popularize color holography. The paper discusses the design and the results obtained.

  5. Imacon 600 ultrafast streak camera evaluation

    International Nuclear Information System (INIS)

    Owen, T.C.; Coleman, L.W.

    1975-01-01

    The Imacon 600 has a number of designed in disadvantages for use as an ultrafast diagnostic instrument. The unit is physically large (approximately 5' long) and uses an external power supply rack for the image intensifier. Water cooling is required for the intensifier; it is quiet but not conducive to portability. There is no interlock on the cooling water. The camera does have several switch selectable sweep speeds. This is desirable if one is working with both slow and fast events. The camera can be run in a framing mode. (MOW)

  6. Nonmedical applications of a positron camera

    International Nuclear Information System (INIS)

    Hawkesworth, M.R.; Parker, D.J.; Fowles, P.; Crilly, J.F.; Jefferies, N.L.; Jonkers, G.

    1991-01-01

    The positron camera in the School on Physics and Space Research, University of Birmingham, is based on position-sensitive multiwire γ-ray detectors developed at the Rutherford Appleton Laboratory. The current characteristics of the camera are discussed with particular reference to its suitability for flow mapping in industrial subjects. The techniques developed for studying the dynamics of processes with time scales ranging from milliseconds to days are described, and examples of recent results from a variety of industrial applications are presented. (orig.)

  7. CBF tomographic measurement with the scintillation camera

    International Nuclear Information System (INIS)

    Kayayan, R.; Philippon, B.; Pehlivanian, E.

    1989-01-01

    Single photon emission tomography (SPECT) allows calculation of regional cerebral blood flow (CBF) in multiple cross-sections of the human brain. The methods of Kanno and Lassen is utilized and a study of reproductibility in terms of integration numbers and period of integrations is performed by computer simulation and experimental study with a Gamma-camera. Finally, the possibility of calculating the regional cerabral blood flow with a double headed rotating Gamma-camera by inert gas inhalation, like the Xenon-133 is discussed [fr

  8. Compact Optical Technique for Streak Camera Calibration

    International Nuclear Information System (INIS)

    Bell, P; Griffith, R; Hagans, K; Lerche, R; Allen, C; Davies, T; Janson, F; Justin, R; Marshall, B; Sweningsen, O

    2004-01-01

    The National Ignition Facility (NIF) is under construction at the Lawrence Livermore National Laboratory (LLNL) for the U.S. Department of Energy Stockpile Stewardship Program. Optical streak cameras are an integral part of the experimental diagnostics instrumentation. To accurately reduce data from the streak cameras a temporal calibration is required. This article describes a technique for generating trains of precisely timed short-duration optical pulses1 (optical comb generators) that are suitable for temporal calibrations. These optical comb generators (Figure 1) are used with the LLNL optical streak cameras. They are small, portable light sources that produce a series of temporally short, uniformly spaced, optical pulses. Comb generators have been produced with 0.1, 0.5, 1, 3, 6, and 10-GHz pulse trains of 780-nm wavelength light with individual pulse durations of ∼25-ps FWHM. Signal output is via a fiber-optic connector. Signal is transported from comb generator to streak camera through multi-mode, graded-index optical fibers. At the NIF, ultra-fast streak-cameras are used by the Laser Fusion Program experimentalists to record fast transient optical signals. Their temporal resolution is unmatched by any other transient recorder. Their ability to spatially discriminate an image along the input slit allows them to function as a one-dimensional image recorder, time-resolved spectrometer, or multichannel transient recorder. Depending on the choice of photocathode, they can be made sensitive to photon energies from 1.1 eV to 30 keV and beyond. Comb generators perform two important functions for LLNL streak-camera users. First, comb generators are used as a precision time-mark generator for calibrating streak camera sweep rates. Accuracy is achieved by averaging many streak camera images of comb generator signals. Time-base calibrations with portable comb generators are easily done in both the calibration laboratory and in situ. Second, comb signals are applied

  9. Iridium Interfacial Stack - IrIS

    Science.gov (United States)

    Spry, David

    2012-01-01

    Iridium Interfacial Stack (IrIS) is the sputter deposition of high-purity tantalum silicide (TaSi2-400 nm)/platinum (Pt-200 nm)/iridium (Ir-200 nm)/platinum (Pt-200 nm) in an ultra-high vacuum system followed by a 600 C anneal in nitrogen for 30 minutes. IrIS simultaneously acts as both a bond metal and a diffusion barrier. This bondable metallization that also acts as a diffusion barrier can prevent oxygen from air and gold from the wire-bond from infiltrating silicon carbide (SiC) monolithically integrated circuits (ICs) operating above 500 C in air for over 1,000 hours. This TaSi2/Pt/Ir/Pt metallization is easily bonded for electrical connection to off-chip circuitry and does not require extra anneals or masking steps. There are two ways that IrIS can be used in SiC ICs for applications above 500 C: it can be put directly on a SiC ohmic contact metal, such as Ti, or be used as a bond metal residing on top of an interconnect metal. For simplicity, only the use as a bond metal is discussed. The layer thickness ratio of TaSi2 to the first Pt layer deposited thereon should be 2:1. This will allow Si from the TaSi2 to react with the Pt to form Pt2Si during the 600 C anneal carried out after all layers have been deposited. The Ir layer does not readily form a silicide at 600 C, and thereby prevents the Si from migrating into the top-most Pt layer during future anneals and high-temperature IC operation. The second (i.e., top-most) deposited Pt layer needs to be about 200 nm to enable easy wire bonding. The thickness of 200 nm for Ir was chosen for initial experiments; further optimization of the Ir layer thickness may be possible via further experimentation. Ir itself is not easily wire-bonded because of its hardness and much higher melting point than Pt. Below the iridium layer, the TaSi2 and Pt react and form desired Pt2Si during the post-deposition anneal while above the iridium layer remains pure Pt as desired to facilitate easy and strong wire-bonding to the Si

  10. Tracking Foodborne Pathogenic Bacteria in Raw and Ready-to-Eat Food Illegally Sold at the Eastern EU Border.

    Science.gov (United States)

    Ciolacu, Luminita; Stessl, Beatrix; Bolocan, Andrei Sorin; Oniciuc, Elena Alexandra; Wagner, Martin; Rychli, Kathrin; Nicolau, Anca Ioana

    2016-03-01

    Food illegally brought into the European Union, mainly in the personal luggage of travelers, represents a potential threat to consumers' health. The aim of this study was to investigate the presence of five pathogens in food brought into the European Union by Moldavian citizens as personal goods and illegally sold in Romania in the vicinity of the border. The occurrence of Staphylococcus aureus and Listeria monocytogenes was 7.5% and 8%, while Campylobacter spp., Escherichia coli O157:H7, and Salmonella spp. were absent in all samples. L. monocytogenes sequence type 2, 9, 121, and 155, highly prevalent among foodstuffs worldwide, was also present among isolates from ready-to-eat food illegally sold in Romania, even at the same date of sampling, indicating cross-contamination during food handling. S. aureus spa types t449, t304, and t524 were most often isolated from raw-milk cheeses contaminated with 10(3)-10(5) colony-forming units per gram, evidencing a contamination at herd level or unhygienic conditions during processing. S. aureus t011 and t3625, both included in the livestock-associated CC398, were isolated from pork lard and poultry meat. This study shows that cross-border trade from nonmember states represents a neglected route of transmission of foodborne pathogens into the European Union that could lead to sporadic or family-associated cases of disease.

  11. Bacteriological And Nutritional Analysis Of Groundnut Cake Sold In An Open Market In Samaru Zaria-Kaduna State

    Directory of Open Access Journals (Sweden)

    Oko

    2015-05-01

    Full Text Available Abstract Bacteriological and nutritional analysis of groundnut cake powder sold in open market at Samaru-Zaria was studied. The samples collected from four zones of the study area were analysed for possible microbiological contamination and its nutritional quality. The results indicated a microbial load of 1.93 x 105 cfug and 1.94 x 105 cfug for zones A and B respectively 1.01 x 105 cfug for zone C and 2.37 x 105 cfug for zone D. The bacterial isolates found to be associated with the groundnut cake powder in this study included Klebsiella oxytoca Staphylococcus aureus Bacillus cereus E. coli P. aeruginosa and Streptococcus feacalis. The nutrients content of the sample included carbohydrates 55.15 moisture 12.65 lipid 15.40 protein 12.60 ash 3.95 and crude fibre 0.25. Groundnut cake sold in the study area is highly contaminated with bacteria except for samples from zone C which is within the Food and Drugs Agency FDA recommendation of 1.0 x 105cfuml as allowable microbial contamination for food. The high level of microbial contamination is a serious cause for concern as it may trigger epidemics. However the product is highly nutritious.

  12. Quality evaluation of commercially sold table water samples in Michael Okpara University of Agriculture, Umudike, Nigeria and surrounding environments

    Directory of Open Access Journals (Sweden)

    D.O. Okorie

    2015-01-01

    Full Text Available In Michael Okpara University of Agriculture, Umudike, Nigeria (MOUAU and surrounding environments, table water of different brands is commercially hawked by vendors. To the best of our knowledge, there is no scientific documentation on the quality of these water samples. Hence this study which evaluated the quality of different brands of water samples commercially sold in MOUAU and surrounding environments. The physicochemical properties (pH, total dissolved solids (TDS, biochemical oxygen demand (BOD, total hardness, dissolved oxygen, Cl, NO3, ammonium nitrogen (NH3N, turbidity, total suspended solids (TSS, Ca, Mg, Na and K of the water samples as indices of their quality were carried out using standard techniques. Results obtained from this study indicated that most of the chemical constituents of these table water samples commercially sold in Umudike environment conformed to the standards given by the Nigerian Industrial Standard (NIS, World Health Organization (WHO and American Public Health Association (APHA, respectively, while values obtained for ammonium nitrogen in these water samples calls for serious checks on methods of their production and delivery to the end users.

  13. How do different cigarette design features influence the standard tar yields of popular cigarette brands sold in different countries?

    Science.gov (United States)

    O'Connor, R J; Hammond, D; McNeill, A; King, B; Kozlowski, L T; Giovino, G A; Cummings, K M

    2008-09-01

    To examine the associations among cigarette design features and tar yields of leading cigarette brands sold in the United States, Canada, Australia and the United Kingdom. Government reports and numbers listed on packs were used to obtain data on International Organization for Standardization (ISO)/Federal Trade Commission (FTC) yields for the tar of 172 cigarette varieties sold in the United States, Canada, Australia and the United Kingdom. We used standardised methods to measure the following 11 cigarette design parameters: filter ventilation, cigarette pressure drop, filter pressure drop, tobacco rod length, filter length, cigarette diameter, tipping paper length, tobacco weight, filter weight, rod density and filter density. Filter ventilation was found to be the predominant design feature accounting for the variations between brands in ISO/FTC tar yields in each of the four countries. After accounting for filter ventilation, design parameters such as overwrap length, tobacco weight and rod density played comparatively minor roles in determining tar yields. Variation in ISO/FTC tar yields are predicted by a limited set of cigarette design features, especially filter ventilation, suggesting that governments should consider mandatory disclosure of cigarette design parameters as part of comprehensive tobacco product regulations.

  14. Evaluation of mobile phone camera benchmarking using objective camera speed and image quality metrics

    Science.gov (United States)

    Peltoketo, Veli-Tapani

    2014-11-01

    When a mobile phone camera is tested and benchmarked, the significance of image quality metrics is widely acknowledged. There are also existing methods to evaluate the camera speed. However, the speed or rapidity metrics of the mobile phone's camera system has not been used with the quality metrics even if the camera speed has become a more and more important camera performance feature. There are several tasks in this work. First, the most important image quality and speed-related metrics of a mobile phone's camera system are collected from the standards and papers and, also, novel speed metrics are identified. Second, combinations of the quality and speed metrics are validated using mobile phones on the market. The measurements are done toward application programming interface of different operating systems. Finally, the results are evaluated and conclusions are made. The paper defines a solution to combine different image quality and speed metrics to a single benchmarking score. A proposal of the combined benchmarking metric is evaluated using measurements of 25 mobile phone cameras on the market. The paper is a continuation of a previous benchmarking work expanded with visual noise measurement and updates of the latest mobile phone versions.

  15. Suppression of superconductivity in Nb by IrMn in IrMn/Nb bilayers

    KAUST Repository

    Wu, B. L.; Yang, Y. M.; Guo, Z. B.; Wu, Y. H.; Qiu, J. J.

    2013-01-01

    Effect of antiferromagnet on superconductivity has been investigated in IrMn/Nb bilayers. Significant suppression of both transition temperature (Tc) and lower critical field (Hc1) of Nb is found in IrMn/Nb bilayers as compared to a single layer Nb

  16. Single-nucleotide polymorphism of INS, INSR, IRS1, IRS2, PPAR-G ...

    Indian Academy of Sciences (India)

    2017-03-02

    Mar 2, 2017 ... Abstract. Polycystic ovary syndrome (PCOS) is the most common and a complex female endocrine disorder, and is one of the leading cause of female infertility. Here, we aimed to investigate the association of single-nucleotide polymorphism of INS, INSR,. IRS1, IRS2, PPAR-G and CAPN10 gene in the ...

  17. The LLL compact 10-ps streak camera

    International Nuclear Information System (INIS)

    Thomas, S.W.; Houghton, J.W.; Tripp, G.R.; Coleman, L.W.

    1975-01-01

    The 10-ps streak camera has been redesigned to simplify its operation, reduce manufacturing costs, and improve its appearance. The electronics have been simplified, a film indexer added, and a contacted slit has been evaluated. Data support a 10-ps resolution. (author)

  18. Toward standardising gamma camera quality control procedures

    International Nuclear Information System (INIS)

    Alkhorayef, M.A.; Alnaaimi, M.A.; Alduaij, M.A.; Mohamed, M.O.; Ibahim, S.Y.; Alkandari, F.A.; Bradley, D.A.

    2015-01-01

    Attaining high standards of efficiency and reliability in the practice of nuclear medicine requires appropriate quality control (QC) programs. For instance, the regular evaluation and comparison of extrinsic and intrinsic flood-field uniformity enables the quick correction of many gamma camera problems. Whereas QC tests for uniformity are usually performed by exposing the gamma camera crystal to a uniform flux of gamma radiation from a source of known activity, such protocols can vary significantly. Thus, there is a need for optimization and standardization, in part to allow direct comparison between gamma cameras from different vendors. In the present study, intrinsic uniformity was examined as a function of source distance, source activity, source volume and number of counts. The extrinsic uniformity and spatial resolution were also examined. Proper standard QC procedures need to be implemented because of the continual development of nuclear medicine imaging technology and the rapid expansion and increasing complexity of hybrid imaging system data. The present work seeks to promote a set of standard testing procedures to contribute to the delivery of safe and effective nuclear medicine services. - Highlights: • Optimal parameters for quality control of the gamma camera are proposed. • For extrinsic and intrinsic uniformity a minimum of 15,000 counts is recommended. • For intrinsic flood uniformity the activity should not exceed 100 µCi (3.7 MBq). • For intrinsic uniformity the source to detector distance should be at least 60 cm. • The bar phantom measurement must be performed with at least 15 million counts.

  19. Increased Automation in Stereo Camera Calibration Techniques

    Directory of Open Access Journals (Sweden)

    Brandi House

    2006-08-01

    Full Text Available Robotic vision has become a very popular field in recent years due to the numerous promising applications it may enhance. However, errors within the cameras and in their perception of their environment can cause applications in robotics to fail. To help correct these internal and external imperfections, stereo camera calibrations are performed. There are currently many accurate methods of camera calibration available; however, most or all of them are time consuming and labor intensive. This research seeks to automate the most labor intensive aspects of a popular calibration technique developed by Jean-Yves Bouguet. His process requires manual selection of the extreme corners of a checkerboard pattern. The modified process uses embedded LEDs in the checkerboard pattern to act as active fiducials. Images are captured of the checkerboard with the LEDs on and off in rapid succession. The difference of the two images automatically highlights the location of the four extreme corners, and these corner locations take the place of the manual selections. With this modification to the calibration routine, upwards of eighty mouse clicks are eliminated per stereo calibration. Preliminary test results indicate that accuracy is not substantially affected by the modified procedure. Improved automation to camera calibration procedures may finally penetrate the barriers to the use of calibration in practice.

  20. Thermoplastic film camera for holographic recording

    International Nuclear Information System (INIS)

    Liegeois, C.; Meyrueis, P.

    1982-01-01

    The design thermoplastic-film recording camera and its performance for holography of extended objects are reported. Special corona geometry and accurate control of development heat by constant current heating and high resolution measurement of the develop temperature make easy recording of reproducible, large aperture holograms possible. The experimental results give the transfer characteristics, the diffraction efficiency characteristics and the spatial frequency response. (orig.)

  1. A novel super-resolution camera model

    Science.gov (United States)

    Shao, Xiaopeng; Wang, Yi; Xu, Jie; Wang, Lin; Liu, Fei; Luo, Qiuhua; Chen, Xiaodong; Bi, Xiangli

    2015-05-01

    Aiming to realize super resolution(SR) to single image and video reconstruction, a super resolution camera model is proposed for the problem that the resolution of the images obtained by traditional cameras behave comparatively low. To achieve this function we put a certain driving device such as piezoelectric ceramics in the camera. By controlling the driving device, a set of continuous low resolution(LR) images can be obtained and stored instantaneity, which reflect the randomness of the displacements and the real-time performance of the storage very well. The low resolution image sequences have different redundant information and some particular priori information, thus it is possible to restore super resolution image factually and effectively. The sample method is used to derive the reconstruction principle of super resolution, which analyzes the possible improvement degree of the resolution in theory. The super resolution algorithm based on learning is used to reconstruct single image and the variational Bayesian algorithm is simulated to reconstruct the low resolution images with random displacements, which models the unknown high resolution image, motion parameters and unknown model parameters in one hierarchical Bayesian framework. Utilizing sub-pixel registration method, a super resolution image of the scene can be reconstructed. The results of 16 images reconstruction show that this camera model can increase the image resolution to 2 times, obtaining images with higher resolution in currently available hardware levels.

  2. Scintillation camera for high activity sources

    International Nuclear Information System (INIS)

    Arseneau, R.E.

    1976-01-01

    A scintillation camera is provided with electrical components which expand the intrinsic maximum rate of acceptance for processing of pulses emanating from detected radioactive events. Buffer storage is provided to accommodate temporary increases in the level of radioactivity. An early provisional determination of acceptability of pulses allows many unacceptable pulses to be discarded at an early stage

  3. Novel computer-based endoscopic camera

    Science.gov (United States)

    Rabinovitz, R.; Hai, N.; Abraham, Martin D.; Adler, Doron; Nissani, M.; Fridental, Ron; Vitsnudel, Ilia

    1995-05-01

    We have introduced a computer-based endoscopic camera which includes (a) unique real-time digital image processing to optimize image visualization by reducing over exposed glared areas and brightening dark areas, and by accentuating sharpness and fine structures, and (b) patient data documentation and management. The image processing is based on i Sight's iSP1000TM digital video processor chip and Adaptive SensitivityTM patented scheme for capturing and displaying images with wide dynamic range of light, taking into account local neighborhood image conditions and global image statistics. It provides the medical user with the ability to view images under difficult lighting conditions, without losing details `in the dark' or in completely saturated areas. The patient data documentation and management allows storage of images (approximately 1 MB per image for a full 24 bit color image) to any storage device installed into the camera, or to an external host media via network. The patient data which is included with every image described essential information on the patient and procedure. The operator can assign custom data descriptors, and can search for the stored image/data by typing any image descriptor. The camera optics has extended zoom range of f equals 20 - 45 mm allowing control of the diameter of the field which is displayed on the monitor such that the complete field of view of the endoscope can be displayed on all the area of the screen. All these features provide versatile endoscopic camera with excellent image quality and documentation capabilities.

  4. FPS camera sync and reset chassis

    International Nuclear Information System (INIS)

    Yates, G.J.

    1980-06-01

    The sync and reset chassis provides all the circuitry required to synchronize an event to be studied, a remote free-running focus projection and scanning (FPS) data-acquisition TV camera, and a video signal recording system. The functions, design, and operation of this chassis are described in detail

  5. Lessons Learned from Crime Caught on Camera

    DEFF Research Database (Denmark)

    Lindegaard, Marie Rosenkrantz; Bernasco, Wim

    2018-01-01

    Objectives: The widespread use of camera surveillance in public places offers criminologists the opportunity to systematically and unobtrusively observe crime, their main subject matter. The purpose of this essay is to inform the reader of current developments in research on crimes caught on came...

  6. Terrain mapping camera for Chandrayaan-1

    Indian Academy of Sciences (India)

    The camera will have four gain settings to cover the varying illumination conditions of the Moon. Additionally, a provision of imaging with reduced resolution, for improving Signal-to-Noise Ratio (SNR) in polar regions, which have poor illumination conditions throughout, has been made. SNR of better than 100 is expected in ...

  7. Fog camera to visualize ionizing charged particles

    International Nuclear Information System (INIS)

    Trujillo A, L.; Rodriguez R, N. I.; Vega C, H. R.

    2014-10-01

    The human being can not perceive the different types of ionizing radiation, natural or artificial, present in the nature, for what appropriate detection systems have been developed according to the sensibility to certain radiation type and certain energy type. The objective of this work was to build a fog camera to visualize the traces, and to identify the trajectories, produced by charged particles with high energy, coming mainly of the cosmic rays. The origin of the cosmic rays comes from the solar radiation generated by solar eruptions where the protons compose most of this radiation. It also comes, of the galactic radiation which is composed mainly of charged particles and gamma rays that comes from outside of the solar system. These radiation types have energy time millions higher that those detected in the earth surface, being more important as the height on the sea level increases. These particles in their interaction produce secondary particles that are detectable by means of this cameras type. The camera operates by means of a saturated atmosphere of alcohol vapor. In the moment in that a charged particle crosses the cold area of the atmosphere, the medium is ionized and the particle acts like a condensation nucleus of the alcohol vapor, leaving a visible trace of its trajectory. The built camera was very stable, allowing the detection in continuous form and the observation of diverse events. (Author)

  8. The Legal Implications of Surveillance Cameras

    Science.gov (United States)

    Steketee, Amy M.

    2012-01-01

    The nature of school security has changed dramatically over the last decade. Schools employ various measures, from metal detectors to identification badges to drug testing, to promote the safety and security of staff and students. One of the increasingly prevalent measures is the use of security cameras. In fact, the U.S. Department of Education…

  9. The infrared camera prototype characterization for the JEM-EUSO space mission

    International Nuclear Information System (INIS)

    Morales de los Ríos, J.A.; Joven, E.; Peral, L. del; Reyes, M.; Licandro, J.; Rodríguez Frías, M.D.

    2014-01-01

    JEM-EUSO (Extreme Universe Space Observatory on Japanese Experiment Module) is an advanced observatory that will be on-board the International Space Station (ISS) and use the Earth's atmosphere as a huge calorimeter detector. However, the atmospheric clouds introduce uncertainties in the signals measured by JEM-EUSO. Therefore, it is extremely important to know the atmospheric conditions and properties of the clouds in the Field of View (FoV) of the telescope. The Atmospheric Monitoring System (AMS) of JEM-EUSO includes a lidar and an infrared imaging system, IR-Camera, aimed to detect the presence of clouds and to obtain the cloud coverage and cloud top altitude during the observations of the JEM-EUSO main telescope. To define the road-map for the design of the electronics, the detector has been tested extensively with a first prototype. The actual design of the IR-Camera, the test of the prototype, and the outcome of this characterization are presented in this paper

  10. The infrared camera prototype characterization for the JEM-EUSO space mission

    Energy Technology Data Exchange (ETDEWEB)

    Morales de los Ríos, J.A., E-mail: josealberto.morales@uah.es [SPace and AStroparticle (SPAS) Group, UAH, Madrid (Spain); Ebisuzaki Computational Astrophysics Laboratory, RIKEN (Japan); Joven, E. [Instituto de Astrofísica de Canarias (IAC), Tenerife (Spain); Peral, L. del [SPace and AStroparticle (SPAS) Group, UAH, Madrid (Spain); Leonard E. Parker Center for Gravitation, Cosmology and Astrophysics, University of Wisconsin-Milwaukee (United States); Reyes, M. [Instituto de Astrofísica de Canarias (IAC), Tenerife (Spain); Licandro, J. [Instituto de Astrofísica de Canarias (IAC), Tenerife (Spain); Departamento de Astrofísica, Universidad de La Laguna, Tenerife (Spain); Rodríguez Frías, M.D. [SPace and AStroparticle (SPAS) Group, UAH, Madrid (Spain); Instituto de Astrofísica de Canarias (IAC), Tenerife (Spain)

    2014-06-01

    JEM-EUSO (Extreme Universe Space Observatory on Japanese Experiment Module) is an advanced observatory that will be on-board the International Space Station (ISS) and use the Earth's atmosphere as a huge calorimeter detector. However, the atmospheric clouds introduce uncertainties in the signals measured by JEM-EUSO. Therefore, it is extremely important to know the atmospheric conditions and properties of the clouds in the Field of View (FoV) of the telescope. The Atmospheric Monitoring System (AMS) of JEM-EUSO includes a lidar and an infrared imaging system, IR-Camera, aimed to detect the presence of clouds and to obtain the cloud coverage and cloud top altitude during the observations of the JEM-EUSO main telescope. To define the road-map for the design of the electronics, the detector has been tested extensively with a first prototype. The actual design of the IR-Camera, the test of the prototype, and the outcome of this characterization are presented in this paper.

  11. Divergence-ratio axi-vision camera (Divcam): A distance mapping camera

    International Nuclear Information System (INIS)

    Iizuka, Keigo

    2006-01-01

    A novel distance mapping camera the divergence-ratio axi-vision camera (Divcam) is proposed. The decay rate of the illuminating light with distance due to the divergence of the light is used as means of mapping the distance. Resolutions of 10 mm over a range of meters and 0.5 mm over a range of decimeters were achieved. The special features of this camera are its high resolution real-time operation, simplicity, compactness, light weight, portability, and yet low fabrication cost. The feasibility of various potential applications is also included

  12. Integrating Gigabit ethernet cameras into EPICS at Diamond light source

    International Nuclear Information System (INIS)

    Cobb, T.

    2012-01-01

    At Diamond Light Source a range of cameras are used to provide images for diagnostic purposes in both the accelerator and photo beamlines. The accelerator and existing beamlines use Point Grey Flea and Flea2 Firewire cameras. We have selected Gigabit Ethernet cameras supporting GigE Vision for our new photon beamlines. GigE Vision is an interface standard for high speed Ethernet cameras which encourages inter-operability between manufacturers. This paper describes the challenges encountered while integrating GigE Vision cameras from a range of vendors into EPICS. GigE Vision cameras appear to be more reliable than the Firewire cameras, and the simple cabling makes much easier to move the cameras to different positions. Upcoming power over Ethernet versions of the cameras will reduce the number of cables still further

  13. New nuclear medicine gamma camera systems

    International Nuclear Information System (INIS)

    Villacorta, Edmundo V.

    1997-01-01

    The acquisition of the Open E.CAM and DIACAM gamma cameras by Makati Medical Center is expected to enhance the capabilities of its nuclear medicine facilities. When used as an aid to diagnosis, nuclear medicine entails the introduction of a minute amount of radioactive material into the patient; thus, no reaction or side-effect is expected. When it reaches the particular target organ, depending on the radiopharmaceutical, a lesion will appear as a decrease (cold) area or increase (hot) area in the radioactive distribution as recorded byu the gamma cameras. Gamma camera images in slices or SPECT (Single Photon Emission Computer Tomography), increase the sensitivity and accuracy in detecting smaller and deeply seated lesions, which otherwise may not be detected in the regular single planar images. Due to the 'open' design of the equipment, claustrophobic patients will no longer feel enclosed during the procedure. These new gamma cameras yield improved resolution and superb image quality, and the higher photon sensitivity shortens imaging acquisition time. The E.CAM, which is the latest generation gamma camera, is featured by its variable angle dual-head system, the only one available in the Philipines, and the excellent choice for Myocardial Perfusion Imaging (MPI). From the usual 45 minutes, the acquisition time for gated SPECT imaging of the heart has now been remarkably reduced to 12 minutes. 'Gated' infers snap-shots of the heart in selected phases of its contraction and relaxation as triggered by ECG. The DIACAM is installed in a room with access outside the main entrance of the department, intended specially for bed-borne patients. Both systems are equipped with a network of high performance Macintosh ICOND acquisition and processing computers. Added to the hardware is the ICON processing software which allows total simultaneous acquisition and processing capabilities in the same operator's terminal. Video film and color printers are also provided. Together

  14. X-ray imaging using digital cameras

    Science.gov (United States)

    Winch, Nicola M.; Edgar, Andrew

    2012-03-01

    The possibility of using the combination of a computed radiography (storage phosphor) cassette and a semiprofessional grade digital camera for medical or dental radiography is investigated. We compare the performance of (i) a Canon 5D Mk II single lens reflex camera with f1.4 lens and full-frame CMOS array sensor and (ii) a cooled CCD-based camera with a 1/3 frame sensor and the same lens system. Both systems are tested with 240 x 180 mm cassettes which are based on either powdered europium-doped barium fluoride bromide or needle structure europium-doped cesium bromide. The modulation transfer function for both systems has been determined and falls to a value of 0.2 at around 2 lp/mm, and is limited by light scattering of the emitted light from the storage phosphor rather than the optics or sensor pixelation. The modulation transfer function for the CsBr:Eu2+ plate is bimodal, with a high frequency wing which is attributed to the light-guiding behaviour of the needle structure. The detective quantum efficiency has been determined using a radioisotope source and is comparatively low at 0.017 for the CMOS camera and 0.006 for the CCD camera, attributed to the poor light harvesting by the lens. The primary advantages of the method are portability, robustness, digital imaging and low cost; the limitations are the low detective quantum efficiency and hence signal-to-noise ratio for medical doses, and restricted range of plate sizes. Representative images taken with medical doses are shown and illustrate the potential use for portable basic radiography.

  15. Photogrammetric Applications of Immersive Video Cameras

    Science.gov (United States)

    Kwiatek, K.; Tokarczyk, R.

    2014-05-01

    The paper investigates immersive videography and its application in close-range photogrammetry. Immersive video involves the capture of a live-action scene that presents a 360° field of view. It is recorded simultaneously by multiple cameras or microlenses, where the principal point of each camera is offset from the rotating axis of the device. This issue causes problems when stitching together individual frames of video separated from particular cameras, however there are ways to overcome it and applying immersive cameras in photogrammetry provides a new potential. The paper presents two applications of immersive video in photogrammetry. At first, the creation of a low-cost mobile mapping system based on Ladybug®3 and GPS device is discussed. The amount of panoramas is much too high for photogrammetric purposes as the base line between spherical panoramas is around 1 metre. More than 92 000 panoramas were recorded in one Polish region of Czarny Dunajec and the measurements from panoramas enable the user to measure the area of outdoors (adverting structures) and billboards. A new law is being created in order to limit the number of illegal advertising structures in the Polish landscape and immersive video recorded in a short period of time is a candidate for economical and flexible measurements off-site. The second approach is a generation of 3d video-based reconstructions of heritage sites based on immersive video (structure from immersive video). A mobile camera mounted on a tripod dolly was used to record the interior scene and immersive video, separated into thousands of still panoramas, was converted from video into 3d objects using Agisoft Photoscan Professional. The findings from these experiments demonstrated that immersive photogrammetry seems to be a flexible and prompt method of 3d modelling and provides promising features for mobile mapping systems.

  16. A novel fully integrated handheld gamma camera

    International Nuclear Information System (INIS)

    Massari, R.; Ucci, A.; Campisi, C.; Scopinaro, F.; Soluri, A.

    2016-01-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  17. A novel fully integrated handheld gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Massari, R.; Ucci, A.; Campisi, C. [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy); Scopinaro, F. [University of Rome “La Sapienza”, S. Andrea Hospital, Rome (Italy); Soluri, A., E-mail: alessandro.soluri@ibb.cnr.it [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy)

    2016-10-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  18. Kas netilpo tarp politikos ir diplomatijos?

    OpenAIRE

    Streikus, Arūnas

    2008-01-01

    The review analyzes A. Kasparavičius’s monograph “Tarp Politikos ir Diplomatijos: Šventasis Sostas ir Lietuvos Respublika” (Vilnius, 2008). The historiographic value of the study is undisputed. A. Kasperavičius had an opportunity to use a broad spectrum of sources, among which two sets of archive documents stand out: the funds of the archives of Ministry of Foreign Affairs of Lithuania and the Lithuanian Embassy under the Holy See in Rome. A. Kasparavičius managed to avoid the arid scientific...

  19. Elecciones Legislativas en Irán

    Directory of Open Access Journals (Sweden)

    José Antonio Sainz de la Peña

    2012-05-01

    Full Text Available Las elecciones legislativas en Irán, una vez eliminados los reformistas se han celebrado en un clima de rivalidad. Las elecciones tenían que dejar claro quién mandaba en Irán, si los clérigos y el Guía el ayatolá Seyed Ali Jamenei o, el Presidente de la República, el laico Mahmud Ahmadineyad, apoyado en el Cuerpo de Guardias Revolucionarios. La realidad ha sido que las facciones conservadoras encabezadas por el Frente Unido Principalista, apoyados por el Guía Supremo, han obtenido el triunfo.

  20. VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

    Science.gov (United States)

    Champey, Patrick R.; Kobayashi, Ken; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, B.; Beabout, D.; Stewart, M.

    2015-01-01

    The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

  1. DNA barcoding unveils skate (Chondrichthyes: Rajidae) species diversity in 'ray' products sold across Ireland and the UK.

    Science.gov (United States)

    Griffiths, Andrew Mark; Miller, Dana D; Egan, Aaron; Fox, Jennifer; Greenfield, Adam; Mariani, Stefano

    2013-01-01

    Skates are widely consumed across the globe, but many large species are subject to considerable concern regarding their conservation and management. Within Europe such issues have recently driven policy changes so that, for the first time, reports of skate landings now have to be made under species-specific names. Total allowable catches have also been established for many groups, which have been set to zero for a number of the most vulnerable species (e.g., Dipturus batis, Raja undulata and Rostoraja alba). Whilst accurate species identification has become an important issue for landings, the sale of skates is still usually made under a blanket term of "skate" or "ray". The matter of identifying species of skate is further complicated by their morphologically conservative nature and the fact that they are commercially valued for their wings. Thus, before sale their bodies are usually discarded (i.e., "winged") and often skinned, making morphological identification impossible. For the first time, DNA barcoding (of the mitochondrial COI gene) was applied to samples of skate wings from retail outlets across the British Isles, providing insight into which species are sold for consumption. A total of 98 wing samples were analysed, revealing that six species were sold; blonde ray (Raja brachyura), spotted ray (Raja montagui), thornback ray (Raja clavata), cuckoo ray (Leucoraja naevus) small-eyed ray (Raja microocellata) and shagreen ray (Leucoraja fullonica). Statistical testing demonstrated that there were significant differences in the species sold in the distinct retail groups which suggests complex drivers behind the patterns of sale in skates. The results also indicate that endangered species are not commonly being passed on to consumers. In addition, the practice of selling skate wings under ambiguous labels is highlighted as it makes it extremely difficult for consumers to exercise a right to avoid species of conservation concern. Interestingly, a single retailer

  2. DNA barcoding unveils skate (Chondrichthyes: Rajidae) species diversity in ‘ray’ products sold across Ireland and the UK

    Science.gov (United States)

    Egan, Aaron; Fox, Jennifer; Greenfield, Adam; Mariani, Stefano

    2013-01-01

    Skates are widely consumed across the globe, but many large species are subject to considerable concern regarding their conservation and management. Within Europe such issues have recently driven policy changes so that, for the first time, reports of skate landings now have to be made under species-specific names. Total allowable catches have also been established for many groups, which have been set to zero for a number of the most vulnerable species (e.g., Dipturus batis, Raja undulata and Rostoraja alba). Whilst accurate species identification has become an important issue for landings, the sale of skates is still usually made under a blanket term of “skate” or “ray”. The matter of identifying species of skate is further complicated by their morphologically conservative nature and the fact that they are commercially valued for their wings. Thus, before sale their bodies are usually discarded (i.e., “winged”) and often skinned, making morphological identification impossible. For the first time, DNA barcoding (of the mitochondrial COI gene) was applied to samples of skate wings from retail outlets across the British Isles, providing insight into which species are sold for consumption. A total of 98 wing samples were analysed, revealing that six species were sold; blonde ray (Raja brachyura), spotted ray (Raja montagui), thornback ray (Raja clavata), cuckoo ray (Leucoraja naevus) small-eyed ray (Raja microocellata) and shagreen ray (Leucoraja fullonica). Statistical testing demonstrated that there were significant differences in the species sold in the distinct retail groups which suggests complex drivers behind the patterns of sale in skates. The results also indicate that endangered species are not commonly being passed on to consumers. In addition, the practice of selling skate wings under ambiguous labels is highlighted as it makes it extremely difficult for consumers to exercise a right to avoid species of conservation concern. Interestingly, a

  3. DNA barcoding unveils skate (Chondrichthyes: Rajidae species diversity in ‘ray’ products sold across Ireland and the UK

    Directory of Open Access Journals (Sweden)

    Andrew Mark Griffiths

    2013-08-01

    Full Text Available Skates are widely consumed across the globe, but many large species are subject to considerable concern regarding their conservation and management. Within Europe such issues have recently driven policy changes so that, for the first time, reports of skate landings now have to be made under species-specific names. Total allowable catches have also been established for many groups, which have been set to zero for a number of the most vulnerable species (e.g., Dipturus batis, Raja undulata and Rostoraja alba. Whilst accurate species identification has become an important issue for landings, the sale of skates is still usually made under a blanket term of “skate” or “ray”. The matter of identifying species of skate is further complicated by their morphologically conservative nature and the fact that they are commercially valued for their wings. Thus, before sale their bodies are usually discarded (i.e., “winged” and often skinned, making morphological identification impossible. For the first time, DNA barcoding (of the mitochondrial COI gene was applied to samples of skate wings from retail outlets across the British Isles, providing insight into which species are sold for consumption. A total of 98 wing samples were analysed, revealing that six species were sold; blonde ray (Raja brachyura, spotted ray (Raja montagui, thornback ray (Raja clavata, cuckoo ray (Leucoraja naevus small-eyed ray (Raja microocellata and shagreen ray (Leucoraja fullonica. Statistical testing demonstrated that there were significant differences in the species sold in the distinct retail groups which suggests complex drivers behind the patterns of sale in skates. The results also indicate that endangered species are not commonly being passed on to consumers. In addition, the practice of selling skate wings under ambiguous labels is highlighted as it makes it extremely difficult for consumers to exercise a right to avoid species of conservation concern

  4. [A Quality Assurance (QA) System with a Web Camera for High-dose-rate Brachytherapy].

    Science.gov (United States)

    Hirose, Asako; Ueda, Yoshihiro; Oohira, Shingo; Isono, Masaru; Tsujii, Katsutomo; Inui, Shouki; Masaoka, Akira; Taniguchi, Makoto; Miyazaki, Masayoshi; Teshima, Teruki

    2016-03-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an (192)Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.31±0.1 mm and that of dwell time errors 0.1±0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size.

  5. A quality assurance (QA) system with a web camera for high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Hirose, Asako; Ueda, Yoshihiro; Ohira, Shingo

    2016-01-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an 192 Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.3±0.1 mm and that of dwell time errors 0.1 ± 0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size. (author)

  6. Encapsulated thermopile detector array for IR microspectrometer

    NARCIS (Netherlands)

    Wu, H.; Emadi, A.; De Graaf, G.; Wolffenbuttel, R.F.

    2010-01-01

    The miniaturized IR spectrometer discussed in this paper is comprised of: slit, planar imaging diffraction grating and Thermo-Electric (TE) detector array, which is fabricated using CMOS compatible MEMS technology. The resolving power is maximized by spacing the TE elements at an as narrow as

  7. TIJAH: Embracing IR Methods in XML Databases

    NARCIS (Netherlands)

    List, Johan; Mihajlovic, V.; Ramirez, Georgina; de Vries, A.P.; Hiemstra, Djoerd; Blok, H.E.

    2005-01-01

    This paper discusses our participation in INEX (the Initiative for the Evaluation of XML Retrieval) using the TIJAH XML-IR system. TIJAH's system design follows a `standard' layered database architecture, carefully separating the conceptual, logical and physical levels. At the conceptual level, we

  8. IR and OLAP in XML document warehouses

    DEFF Research Database (Denmark)

    Perez, Juan Manuel; Pedersen, Torben Bach; Berlanga, Rafael

    2005-01-01

    In this paper we propose to combine IR and OLAP (On-Line Analytical Processing) technologies to exploit a warehouse of text-rich XML documents. In the system we plan to develop, a multidimensional implementation of a relevance modeling document model will be used for interactively querying...

  9. Isolated Gramicidin Peptides Probed by IR Spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Rijs, A. M.; Kabeláč, Martin; Abo-Riziq, A.; Hobza, Pavel; de Vries, M. S.

    2011-01-01

    Roč. 12, č. 10 (2011), s. 1816-1821 ISSN 1439-4235 R&D Projects: GA MŠk LC512; GA AV ČR IAA400550808 Institutional research plan: CEZ:AV0Z40550506 Keywords : density functional calculations * gramicidin * IR spectroscopy * protein folding Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.412, year: 2011

  10. Airborne pipeline leak detection: UV or IR?

    Science.gov (United States)

    Babin, François; Gravel, Jean-François; Allard, Martin

    2016-05-01

    This paper presents a study of different approaches to the measurement of the above ground vapor plume created by the spill caused by a small 0.1 l/min (or less) leak in an underground liquid petroleum pipeline. The scenarios are those for the measurement from an airborne platform. The usual approach is that of IR absorption, but in the case of liquid petroleum products, there are drawbacks that will be discussed, especially when using alkanes to detect a leak. The optical measurements studied include UV enhanced Raman lidar, UV fluorescence lidar and IR absorption path integrated lidars. The breadboards used for testing the different approaches will be described along with the set-ups for leak simulation. Although IR absorption would intuitively be the most sensitive, it is shown that UV-Raman could be an alternative. When using the very broad alkane signature in the IR, the varying ground spectral reflectance are a problem. It is also determined that integrated path measurements are preferred, the UV enhanced Raman measurements showing that the vapor plume stays very close to the ground.

  11. Near IR spectra of symbiotic stars

    International Nuclear Information System (INIS)

    Andrillat, Y.

    1982-01-01

    The author reports on recent observations from the near IR spectra of symbiotic stars. The helium and oxygen lines useful for the construction of theoretical models are identified. Observations for cool stars and novae (nebular phase) are outlined and the spectra of specific symbiotic stars between lambdalambda 8000-11000 are presented and discussed. (Auth./C.F.)

  12. Methanol decomposition and oxidation on Ir(111)

    NARCIS (Netherlands)

    Weststrate, C.J.; Ludwig, W.; Bakker, J.W.; Gluhoi, A.C.; Nieuwenhuys, B.E.

    2007-01-01

    The adsorption, decompn., and oxidn. of methanol (CH3OH) has been studied on Ir(111) using temp.-programmed desorption and high-energy resoln. fast XPS. Mol. methanol desorption from a methanol-satd. surface at low temp. shows three desorption peaks, around 150 K (alpha ), around 170 K (beta 1), and

  13. Column Stores as an IR Prototyping Tool

    NARCIS (Netherlands)

    H.F. Mühleisen (Hannes); T. Samar (Thaer); J.J.P. Lin (Jimmy); A.P. de Vries (Arjen)

    2014-01-01

    textabstract. We make the suggestion that instead of implementing custom index structures and query evaluation algorithms, IR researchers should simply store document representations in a column-oriented relational database and write ranking models using SQL. For rapid prototyping, this is

  14. World's fastest and most sensitive astronomical camera

    Science.gov (United States)

    2009-06-01

    The next generation of instruments for ground-based telescopes took a leap forward with the development of a new ultra-fast camera that can take 1500 finely exposed images per second even when observing extremely faint objects. The first 240x240 pixel images with the world's fastest high precision faint light camera were obtained through a collaborative effort between ESO and three French laboratories from the French Centre National de la Recherche Scientifique/Institut National des Sciences de l'Univers (CNRS/INSU). Cameras such as this are key components of the next generation of adaptive optics instruments of Europe's ground-based astronomy flagship facility, the ESO Very Large Telescope (VLT). ESO PR Photo 22a/09 The CCD220 detector ESO PR Photo 22b/09 The OCam camera ESO PR Video 22a/09 OCam images "The performance of this breakthrough camera is without an equivalent anywhere in the world. The camera will enable great leaps forward in many areas of the study of the Universe," says Norbert Hubin, head of the Adaptive Optics department at ESO. OCam will be part of the second-generation VLT instrument SPHERE. To be installed in 2011, SPHERE will take images of giant exoplanets orbiting nearby stars. A fast camera such as this is needed as an essential component for the modern adaptive optics instruments used on the largest ground-based telescopes. Telescopes on the ground suffer from the blurring effect induced by atmospheric turbulence. This turbulence causes the stars to twinkle in a way that delights poets, but frustrates astronomers, since it blurs the finest details of the images. Adaptive optics techniques overcome this major drawback, so that ground-based telescopes can produce images that are as sharp as if taken from space. Adaptive optics is based on real-time corrections computed from images obtained by a special camera working at very high speeds. Nowadays, this means many hundreds of times each second. The new generation instruments require these

  15. The TApIR experiment. IR absorption spectra of liquid hydrogen isotopologues

    International Nuclear Information System (INIS)

    Groessle, Robin

    2015-01-01

    The scope of the thesis is the infrared absorption spectroscopy of liquid hydrogen isotopologues with the tritium absorption infrared spectroscopy (TApIR) experiment at the tritium laboratory Karlsruhe (TLK). The calibration process from the sample preparation to the reference measurements are described. A further issue is the classical evaluation of FTIR absorption spectra and the extension using the rolling circle filter (RCF) including the effects on statistical and systematical errors. The impact of thermal and nuclear spin temperature on the IR absorption spectra is discussed. An empirical based modeling for the IR absorption spectra of liquid hydrogen isotopologues is performed.

  16. State sales tax rates for soft drinks and snacks sold through grocery stores and vending machines, 2007.

    Science.gov (United States)

    Chriqui, Jamie F; Eidson, Shelby S; Bates, Hannalori; Kowalczyk, Shelly; Chaloupka, Frank J

    2008-07-01

    Junk food consumption is associated with rising obesity rates in the United States. While a "junk food" specific tax is a potential public health intervention, a majority of states already impose sales taxes on certain junk food and soft drinks. This study reviews the state sales tax variance for soft drinks and selected snack products sold through grocery stores and vending machines as of January 2007. Sales taxes vary by state, intended retail location (grocery store vs. vending machine), and product. Vended snacks and soft drinks are taxed at a higher rate than grocery items and other food products, generally, indicative of a "disfavored" tax status attributed to vended items. Soft drinks, candy, and gum are taxed at higher rates than are other items examined. Similar tax schemes in other countries and the potential implications of these findings relative to the relationship between price and consumption are discussed.

  17. Principle of some gamma cameras (efficiencies, limitations, development)

    International Nuclear Information System (INIS)

    Allemand, R.; Bourdel, J.; Gariod, R.; Laval, M.; Levy, G.; Thomas, G.

    1975-01-01

    The quality of scintigraphic images is shown to depend on the efficiency of both the input collimator and the detector. Methods are described by which the quality of these images may be improved by adaptations to either the collimator (Fresnel zone camera, Compton effect camera) or the detector (Anger camera, image amplification camera). The Anger camera and image amplification camera are at present the two main instruments whereby acceptable space and energy resolutions may be obtained. A theoretical comparative study of their efficiencies is carried out, independently of their technological differences, after which the instruments designed or under study at the LETI are presented: these include the image amplification camera, the electron amplifier tube camera using a semi-conductor target CdTe and HgI 2 detector [fr

  18. Notes on the IMACON 500 streak camera system

    International Nuclear Information System (INIS)

    Clendenin, J.E.

    1985-01-01

    The notes provided are intended to supplement the instruction manual for the IMACON 500 streak camera system. The notes cover the streak analyzer, instructions for timing the streak camera, and calibration

  19. Dynamic gamma camera scintigraphy in primary hypoovarism

    International Nuclear Information System (INIS)

    Peshev, N.; Mladenov, B.; Topalov, I.; Tsanev, Ts.

    1988-01-01

    Twenty-seven patients with primary hypoovarism and 10 controls were examined. After intravenous injection of 111 to 175 MBq 99m Tc pertechnetate, dynamic gamma camera scintigraphy for 15 minutes was carried out. In the patients with primary amenorrhea no functioning ovarial tissue was visualized or the ovaries were diminished in size, strongly reduced and non-homogenous accumulation of the radionuclide with unclear and uneven delineation were observed. In the patients with primary infertility, the gamma camera investigation gave information not only about the presence of ovarial parenchyma, but about the extent of the inflammatory process, too. In the patients after surgical intervention, the dynamic radioisotope investigation gave information about the volume and the site of the surgical intervention, as well as about the conditions of the residual parenchyma

  20. Advanced EVA Suit Camera System Development Project

    Science.gov (United States)

    Mock, Kyla

    2016-01-01

    The National Aeronautics and Space Administration (NASA) at the Johnson Space Center (JSC) is developing a new extra-vehicular activity (EVA) suit known as the Advanced EVA Z2 Suit. All of the improvements to the EVA Suit provide the opportunity to update the technology of the video imagery. My summer internship project involved improving the video streaming capabilities of the cameras that will be used on the Z2 Suit for data acquisition. To accomplish this, I familiarized myself with the architecture of the camera that is currently being tested to be able to make improvements on the design. Because there is a lot of benefit to saving space, power, and weight on the EVA suit, my job was to use Altium Design to start designing a much smaller and simplified interface board for the camera's microprocessor and external components. This involved checking datasheets of various components and checking signal connections to ensure that this architecture could be used for both the Z2 suit and potentially other future projects. The Orion spacecraft is a specific project that may benefit from this condensed camera interface design. The camera's physical placement on the suit also needed to be determined and tested so that image resolution can be maximized. Many of the options of the camera placement may be tested along with other future suit testing. There are multiple teams that work on different parts of the suit, so the camera's placement could directly affect their research or design. For this reason, a big part of my project was initiating contact with other branches and setting up multiple meetings to learn more about the pros and cons of the potential camera placements we are analyzing. Collaboration with the multiple teams working on the Advanced EVA Z2 Suit is absolutely necessary and these comparisons will be used as further progress is made for the overall suit design. This prototype will not be finished in time for the scheduled Z2 Suit testing, so my time was

  1. Declarative camera control for automatic cinematography

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, D.B.; Anderson, S.E.; Li-wei He [Univ. of Washington, Seattle, WA (United States)] [and others

    1996-12-31

    Animations generated by interactive 3D computer graphics applications are typically portrayed either from a particular character`s point of view or from a small set of strategically-placed viewpoints. By ignoring camera placement, such applications fail to realize important storytelling capabilities that have been explored by cinematographers for many years. In this paper, we describe several of the principles of cinematography and show how they can be formalized into a declarative language, called the Declarative Camera Control Language (DCCL). We describe the application of DCCL within the context of a simple interactive video game and argue that DCCL represents cinematic knowledge at the same level of abstraction as expert directors by encoding 16 idioms from a film textbook. These idioms produce compelling animations, as demonstrated on the accompanying videotape.

  2. Cervical SPECT Camera for Parathyroid Imaging

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2012-08-31

    Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

  3. Methods of correcting Anger camera deadtime losses

    International Nuclear Information System (INIS)

    Sorenson, J.A.

    1976-01-01

    Three different methods of correcting for Anger camera deadtime loss were investigated. These included analytic methods (mathematical modeling), the marker-source method, and a new method based on counting ''pileup'' events appearing in a pulseheight analyzer window positioned above the photopeak of interest. The studies were done with /sup 99m/Tc on a Searle Radiographics camera with a measured deadtime of about 6 μsec. Analytic methods were found to be unreliable because of unpredictable changes in deadtime with changes in radiation scattering conditions. Both the marker-source method and the pileup-counting method were found to be accurate to within a few percent for true counting rates of up to about 200 K cps, with the pileup-counting method giving better results. This finding applied to sources at depths ranging up to 10 cm of pressed wood. The relative merits of the two methods are discussed

  4. Microbial and physicochemical assays of paracetamol in different brands of analgesic syrups sold in Sana’a City-Yemen

    Directory of Open Access Journals (Sweden)

    Ali G. Al−Kaf

    2015-02-01

    Full Text Available Context: Contamination of pharmaceuticals with microorganisms irrespective whether they are harmful or nonpathogenic can bring about changes in physicochemical characteristics of the drugs. Aims: To assay the microbial and physicochemical characteristics of paracetamol of two hundreds samples of different brands of analgesic syrups sold in Sana’a City, Yemen. Methods: Total viable aerobic count, type of isolated microorganisms, physical properties, and content of active ingredients were identified and evaluated by standard methods and techniques. The SPSS program was used to statistical analysis of variance for results obtained. Results: The total bacterial count of <10 CFU/mL and <100 CFU/mL in 179 (89.5% and 21 (10.5% samples, respectively was recorded, while the total fungal count was ≤10 CFU/mL in all analyzed syrup samples. The isolated bacteria were Bacillus subtilis, Micrococcus fulvum, and Staphylococcus epidermidis while isolated fungi were Aspergillus niger, Aspergillus fumigatus, and Penicillium notatum. Bacillus subtilis and Aspergillus niger were the predominant bacteria and fungi isolated. The color results had a light red liquid with a sweet taste in the analyzed analgesic syrups. The pH values were ranged from 4.44–5.88. However, the density fluctuated from 1.149–1.184 g/mL. The paracetamol concentration as an active ingredient in the analgesic syrup was recorded from 98.19% – 106.53%. Conclusions: This finding showed that all analgesic syrups sold in Sana’a City followed Pharmacopeia specifications on microbial and physicochemical qualities.

  5. Detection of food-borne bacteria in ready to eat betel leaf sold at local markets in Mymensingh.

    Science.gov (United States)

    Haque, Md Mazedul; Sarker, Md Atiqur Rahman; Rifa, Rafia Afroze; Islam, Md Ariful; Khatun, Mst Minara

    2017-09-01

    The present study was undertaken to determine bacterial load as well as characterize bacterial flora of ready to eat (RTE) betel leaf sold at local markets in Mymensingh city. A total of 25 RTE betel leaf samples were collected from five local markets such as Kamal-Ranjit (KR) market, Shesh more, Kewatkhali, Jobber more, and Ganginar par. Total viable count of bacteria in betel leaf (log 10 mean colony forming unit±standard deviation/ml) was 7.58±0.04 for KR market, 7.72±0.06 for Shesh more, 7.62±0.04 for Kewatkhali, 7.40±0.03 for Jobber more, and 7.60±0.06 for Ganginar par. A total of 98 bacterial isolates belong to five genera ( Escherichia coli , Salmonella spp., Vibrio spp., Bacillus spp., and Staphylococcus spp.) were identified. The prevalence of E. coli was 17.34%, Salmonella spp. was 25.51%, Vibrio spp. was 19.39%, Bacillus spp. was 18.37%, and Staphylococcus spp. was 19.39%. Antibiotic sensitivity test showed that all isolates were sensitive to two antibiotics such as ciprofloxacin and gentamicin. Four isolates ( E. coli , Salmonella spp., Vibrio spp., and Staphylococcus spp.) were resistant to two antibiotics (ampicillin and cephalexin). Antibiogram profile of bacterial isolates of betel leaf suggests that they were multidrug resistance. Data of this study indicate that betel leaf sold at local market harbors multidrug resistance food-borne bacteria which might cause public health hazards if these antibiotic resistant transfer to human through food chain.

  6. Microbiological safety and quality control of poultry products sold in retail chains of Saint Petersburg and Leningrad region.

    Directory of Open Access Journals (Sweden)

    A. K. Alieva

    2017-01-01

    Full Text Available Food safety and food raw materials is an important task which needs to be under government’s and public associations’ control, under enterprises which produce and sale them, and other economy departments. Nutrition is one of the most important factors influencing human health. To 70% alien substances of chemical and microbiological origin get into the human body with food. The heavy metals, nitrates, nitrites, pesticides, nitrosescomounds, mycotoxins, antibiotics, radionuclides and others are xenobiotics of chemical origin. The poultry products represented in commercial networks by poultry plants located in Saint-Petersburg and Leningrad region: “Roskar”, “Sinyavinskaya”, “North”, “Lebyazhye” were picked up for analysis. We used the bacteriological, virological, immunological, mycological, and statistical methods of research. Sanitary -hygienic or microbiological safety of food products was evaluated for the contenting of disease-causing (pathogenic microorganisms such as bacteria groups, coliforms, Staphylococcus, Salmonella and etc. in them. The poultry products sold in commercial networks of St. Petersburg were picked up for analysis. After processing the statistical were revealed 6 nosological forms where the leading position has finding colibacillosis – 27%. The number of positive samples for streptococcosis – 18%, staphylococcus – 8%, aspergillosis–2.6%, salmonellosis – 1.8%, pasteurellosis–1.6 %. The microbiological control of food products which can be the sources of infections should be regular for providing inhabitants with harmless poultry products. It is necessary to adopt and to use the modern microbiological criteria of food safety that will allow to realize the monitoring of their conformity with sanitary norms. The results of these analysis shows that the quality of poultry products sold in commercial networks of Saint Petersburg and the Leningrad region meet the standards.

  7. Detection of food-borne bacteria in ready to eat betel leaf sold at local markets in Mymensingh

    Directory of Open Access Journals (Sweden)

    Md. Mazedul Haque

    2017-09-01

    Full Text Available Aim: The present study was undertaken to determine bacterial load as well as characterize bacterial flora of ready to eat (RTE betel leaf sold at local markets in Mymensingh city. Materials and Methods: A total of 25 RTE betel leaf samples were collected from five local markets such as Kamal-Ranjit (KR market, Shesh more, Kewatkhali, Jobber more, and Ganginar par. Results: Total viable count of bacteria in betel leaf (log10 mean colony forming unit±standard deviation/ml was 7.58±0.04 for KR market, 7.72±0.06 for Shesh more, 7.62±0.04 for Kewatkhali, 7.40±0.03 for Jobber more, and 7.60±0.06 for Ganginar par. A total of 98 bacterial isolates belong to five genera (Escherichia coli, Salmonella spp., Vibrio spp., Bacillus spp., and Staphylococcus spp. were identified. The prevalence of E. coli was 17.34%, Salmonella spp. was 25.51%, Vibrio spp. was 19.39%, Bacillus spp. was 18.37%, and Staphylococcus spp. was 19.39%. Antibiotic sensitivity test showed that all isolates were sensitive to two antibiotics such as ciprofloxacin and gentamicin. Four isolates (E. coli, Salmonella spp., Vibrio spp., and Staphylococcus spp. were resistant to two antibiotics (ampicillin and cephalexin. Antibiogram profile of bacterial isolates of betel leaf suggests that they were multidrug resistance. Conclusion: Data of this study indicate that betel leaf sold at local market harbors multidrug resistance food-borne bacteria which might cause public health hazards if these antibiotic resistant transfer to human through food chain.

  8. Multiple-camera tracking: UK government requirements

    Science.gov (United States)

    Hosmer, Paul

    2007-10-01

    The Imagery Library for Intelligent Detection Systems (i-LIDS) is the UK government's new standard for Video Based Detection Systems (VBDS). The standard was launched in November 2006 and evaluations against it began in July 2007. With the first four i-LIDS scenarios completed, the Home Office Scientific development Branch (HOSDB) are looking toward the future of intelligent vision in the security surveillance market by adding a fifth scenario to the standard. The fifth i-LIDS scenario will concentrate on the development, testing and evaluation of systems for the tracking of people across multiple cameras. HOSDB and the Centre for the Protection of National Infrastructure (CPNI) identified a requirement to track targets across a network of CCTV cameras using both live and post event imagery. The Detection and Vision Systems group at HOSDB were asked to determine the current state of the market and develop an in-depth Operational Requirement (OR) based on government end user requirements. Using this OR the i-LIDS team will develop a full i-LIDS scenario to aid the machine vision community in its development of multi-camera tracking systems. By defining a requirement for multi-camera tracking and building this into the i-LIDS standard the UK government will provide a widely available tool that developers can use to help them turn theory and conceptual demonstrators into front line application. This paper will briefly describe the i-LIDS project and then detail the work conducted in building the new tracking aspect of the standard.

  9. Gamma camera scatter suppression unit WAM

    International Nuclear Information System (INIS)

    Kishi, Haruo; Shibahara, Noriyuki; Hirose, Yoshiharu; Shimonishi, Yoshihiro; Oumura, Masahiro; Ikeda, Hozumi; Hamada, Kunio; Ochi, Hironobu; Itagane, Hiroshi.

    1990-01-01

    In gamma camera imaging, scattered radiation is one of big factors to decrease image contrast. Simply, scatter suppression makes signal to noise ratio larger, but it makes statistics error because of radionuclide injection limit to the human body. EWA is a new method that suppresses scattered radiation and improves image contrast. In this article, WAM which is commercialized EWA method by Siemens Gammasonics Inc. is presented. (author)

  10. Quality assessment of gamma camera systems

    International Nuclear Information System (INIS)

    Kindler, M.

    1985-01-01

    There are methods and equipment in nuclear medical diagnostics that allow selective visualisation of the functioning of organs or organ systems, using radioactive substances for labelling and demonstration of metabolic processes. Following a previous contribution on fundamentals and systems components of a gamma camera system, the article in hand deals with the quality characteristics of such a system and with practical quality control and its significance for clinical applications. [de

  11. Combining local and global optimisation for virtual camera control

    OpenAIRE

    Burelli, Paolo; Yannakakis, Georgios N.; 2010 IEEE Symposium on Computational Intelligence and Games

    2010-01-01

    Controlling a virtual camera in 3D computer games is a complex task. The camera is required to react to dynamically changing environments and produce high quality visual results and smooth animations. This paper proposes an approach that combines local and global search to solve the virtual camera control problem. The automatic camera control problem is described and it is decomposed into sub-problems; then a hierarchical architecture that solves each sub-problem using the most appropriate op...

  12. Can Camera Traps Monitor Komodo Dragons a Large Ectothermic Predator?

    OpenAIRE

    Ariefiandy, Achmad; Purwandana, Deni; Seno, Aganto; Ciofi, Claudio; Jessop, Tim S.

    2013-01-01

    Camera trapping has greatly enhanced population monitoring of often cryptic and low abundance apex carnivores. Effectiveness of passive infrared camera trapping, and ultimately population monitoring, relies on temperature mediated differences between the animal and its ambient environment to ensure good camera detection. In ectothermic predators such as large varanid lizards, this criterion is presumed less certain. Here we evaluated the effectiveness of camera trapping to potentially monitor...

  13. Poster: A Software-Defined Multi-Camera Network

    OpenAIRE

    Chen, Po-Yen; Chen, Chien; Selvaraj, Parthiban; Claesen, Luc

    2016-01-01

    The widespread popularity of OpenFlow leads to a significant increase in the number of applications developed in SoftwareDefined Networking (SDN). In this work, we propose the architecture of a Software-Defined Multi-Camera Network consisting of small, flexible, economic, and programmable cameras which combine the functions of the processor, switch, and camera. A Software-Defined Multi-Camera Network can effectively reduce the overall network bandwidth and reduce a large amount of the Capex a...

  14. Theory and applications of smart cameras

    CERN Document Server

    2016-01-01

    This book presents an overview of smart camera systems, considering practical applications but also reviewing fundamental aspects of the underlying technology.  It introduces in a tutorial style the principles of sensing and signal processing, and also describes topics such as wireless connection to the Internet of Things (IoT) which is expected to be the biggest market for smart cameras. It is an excellent guide to the fundamental of smart camera technology, and the chapters complement each other well as the authors have worked as a team under the auspice of GFP(Global Frontier Project), the largest-scale funded research in Korea.  This is the third of three books based on the Integrated Smart Sensors research project, which describe the development of innovative devices, circuits, and system-level enabling technologies.  The aim of the project was to develop common platforms on which various devices and sensors can be loaded, and to create systems offering significant improvements in information processi...

  15. The AOTF-Based NO2 Camera

    Science.gov (United States)

    Dekemper, E.; Fussen, D.; Vanhellemont, F.; Vanhamel, J.; Pieroux, D.; Berkenbosch, S.

    2017-12-01

    In an urban environment, nitrogen dioxide is emitted by a multitude of static and moving point sources (cars, industry, power plants, heating systems,…). Air quality models generally rely on a limited number of monitoring stations which do not capture the whole pattern, neither allow for full validation. So far, there has been a lack of instrument capable of measuring NO2 fields with the necessary spatio-temporal resolution above major point sources (power plants), or more extended ones (cities). We have developed a new type of passive remote sensing instrument aiming at the measurement of 2-D distributions of NO2 slant column densities (SCDs) with a high spatial (meters) and temporal (minutes) resolution. The measurement principle has some similarities with the popular filter-based SO2 camera (used in volcanic and industrial sulfur emissions monitoring) as it relies on spectral images taken at wavelengths where the molecule absorption cross section is different. But contrary to the SO2 camera, the spectral selection is performed by an acousto-optical tunable filter (AOTF) capable of resolving the target molecule's spectral features. A first prototype was successfully tested with the plume of a coal-firing power plant in Romania, revealing the dynamics of the formation of NO2 in the early plume. A lighter version of the NO2 camera is now being tested on other targets, such as oil refineries and urban air masses.

  16. Improvement of passive THz camera images

    Science.gov (United States)

    Kowalski, Marcin; Piszczek, Marek; Palka, Norbert; Szustakowski, Mieczyslaw

    2012-10-01

    Terahertz technology is one of emerging technologies that has a potential to change our life. There are a lot of attractive applications in fields like security, astronomy, biology and medicine. Until recent years, terahertz (THz) waves were an undiscovered, or most importantly, an unexploited area of electromagnetic spectrum. The reasons of this fact were difficulties in generation and detection of THz waves. Recent advances in hardware technology have started to open up the field to new applications such as THz imaging. The THz waves can penetrate through various materials. However, automated processing of THz images can be challenging. The THz frequency band is specially suited for clothes penetration because this radiation does not point any harmful ionizing effects thus it is safe for human beings. Strong technology development in this band have sparked with few interesting devices. Even if the development of THz cameras is an emerging topic, commercially available passive cameras still offer images of poor quality mainly because of its low resolution and low detectors sensitivity. Therefore, THz image processing is very challenging and urgent topic. Digital THz image processing is a really promising and cost-effective way for demanding security and defense applications. In the article we demonstrate the results of image quality enhancement and image fusion of images captured by a commercially available passive THz camera by means of various combined methods. Our research is focused on dangerous objects detection - guns, knives and bombs hidden under some popular types of clothing.

  17. Remote hardware-reconfigurable robotic camera

    Science.gov (United States)

    Arias-Estrada, Miguel; Torres-Huitzil, Cesar; Maya-Rueda, Selene E.

    2001-10-01

    In this work, a camera with integrated image processing capabilities is discussed. The camera is based on an imager coupled to an FPGA device (Field Programmable Gate Array) which contains an architecture for real-time computer vision low-level processing. The architecture can be reprogrammed remotely for application specific purposes. The system is intended for rapid modification and adaptation for inspection and recognition applications, with the flexibility of hardware and software reprogrammability. FPGA reconfiguration allows the same ease of upgrade in hardware as a software upgrade process. The camera is composed of a digital imager coupled to an FPGA device, two memory banks, and a microcontroller. The microcontroller is used for communication tasks and FPGA programming. The system implements a software architecture to handle multiple FPGA architectures in the device, and the possibility to download a software/hardware object from the host computer into its internal context memory. System advantages are: small size, low power consumption, and a library of hardware/software functionalities that can be exchanged during run time. The system has been validated with an edge detection and a motion processing architecture, which will be presented in the paper. Applications targeted are in robotics, mobile robotics, and vision based quality control.

  18. Linearity correction device for a scintillation camera

    Energy Technology Data Exchange (ETDEWEB)

    Lange, Kai

    1978-06-16

    This invention concerns the scintillation cameras still called gamma ray camera. The invention particularly covers the improvement in the resolution and the uniformity of these cameras. Briefly, in the linearity correction device of the invention, the sum is made of the voltage signals of different amplitudes produced by the preamplifiers of all the photomultiplier tubes and the signal obtained is employed to generate bias voltages which represent predetermined percentages of the sum signal. In one design mode, pairs of transistors are blocked when the output signal of the corresponding preamplifier is under a certain point on its gain curve. When the summation of the energies of a given scintillation exceeds this level which corresponds to a first percentage of the total signal, the first transistor of each pair of each line is unblocked, thereby modifying the gain and curve slop. When the total energy of an event exceeds the next preset level, the second transistor is unblocked to alter the shape again, so much so that the curve shows two break points. If needs be, the device can be designed so as to obtain more break points for the increasingly higher levels of energy. Once the signals have been processed as described above, they may be used for calculating the co-ordinates of the scintillation by one of the conventional methods.

  19. ON-POWER DETECTION OF PIPE WALL-THINNED DEFECTS USING IR THERMOGRAPHY IN NPPS

    Directory of Open Access Journals (Sweden)

    JU HYUN KIM

    2014-04-01

    Full Text Available Wall-thinned defects caused by accelerated corrosion due to fluid flow in the inner pipe appear in many structures of the secondary systems in nuclear power plants (NPPs and are a major factor in degrading the integrity of pipes. Wall-thinned defects need to be managed not only when the NPP is under maintenance but also when the NPP is in normal operation. To this end, a test technique was developed in this study to detect such wall-thinned defects based on the temperature difference on the surface of a hot pipe using infrared (IR thermography and a cooling device. Finite element analysis (FEA was conducted to examine the tendency and experimental conditions for the cooling experiment. Based on the FEA results, the equipment was configured before the cooling experiment was conducted. The IR camera was then used to detect defects in the inner pipe of the pipe specimen that had artificially induced defects. The IR thermography developed in this study is expected to help resolve the issues related to the limitations of non-destructive inspection techniques that are currently conducted for NPP secondary systems and is expected to be very useful on the NPPs site.

  20. Metal-Mesh Optical Filter Technology for Mid IR, Far IR, and Submillimeter, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovative, high transmission band-pass filter technology proposed here is an improvement in multilayer metal-mesh filter design and manufacture for the far IR...

  1. IR-IR Conformation Specific Spectroscopy of Na+(Glucose) Adducts

    Science.gov (United States)

    Voss, Jonathan M.; Kregel, Steven J.; Fischer, Kaitlyn C.; Garand, Etienne

    2018-01-01

    We report an IR-IR double resonance study of the structural landscape present in the Na+(glucose) complex. Our experimental approach involves minimal modifications to a typical IR predissociation setup, and can be carried out via ion-dip or isomer-burning methods, providing additional flexibility to suit different experimental needs. In the current study, the single-laser IR predissociation spectrum of Na+(glucose), which clearly indicates contributions from multiple structures, was experimentally disentangled to reveal the presence of three α-conformers and five β-conformers. Comparisons with calculations show that these eight conformations correspond to the lowest energy gas-phase structures with distinctive Na+ coordination. [Figure not available: see fulltext.

  2. Automatic multi-camera calibration for deployable positioning systems

    Science.gov (United States)

    Axelsson, Maria; Karlsson, Mikael; Rudner, Staffan

    2012-06-01

    Surveillance with automated positioning and tracking of subjects and vehicles in 3D is desired in many defence and security applications. Camera systems with stereo or multiple cameras are often used for 3D positioning. In such systems, accurate camera calibration is needed to obtain a reliable 3D position estimate. There is also a need for automated camera calibration to facilitate fast deployment of semi-mobile multi-camera 3D positioning systems. In this paper we investigate a method for automatic calibration of the extrinsic camera parameters (relative camera pose and orientation) of a multi-camera positioning system. It is based on estimation of the essential matrix between each camera pair using the 5-point method for intrinsically calibrated cameras. The method is compared to a manual calibration method using real HD video data from a field trial with a multicamera positioning system. The method is also evaluated on simulated data from a stereo camera model. The results show that the reprojection error of the automated camera calibration method is close to or smaller than the error for the manual calibration method and that the automated calibration method can replace the manual calibration.

  3. Camera Network Coverage Improving by Particle Swarm Optimization

    NARCIS (Netherlands)

    Xu, Y.C.; Lei, B.; Hendriks, E.A.

    2011-01-01

    This paper studies how to improve the field of view (FOV) coverage of a camera network. We focus on a special but practical scenario where the cameras are randomly scattered in a wide area and each camera may adjust its orientation but cannot move in any direction. We propose a particle swarm

  4. A generic model for camera based intelligent road crowd control ...

    African Journals Online (AJOL)

    This research proposes a model for intelligent traffic flow control by implementing camera based surveillance and feedback system. A series of cameras are set minimum three signals ahead from the target junction. The complete software system is developed to help integrating the multiple camera on road as feedback to ...

  5. MISR L1B3 Radiometric Camera-by-camera Cloud Mask Product subset for the RICO region V004

    Data.gov (United States)

    National Aeronautics and Space Administration — This file contains the Radiometric camera-by-camera Cloud Mask dataset over the RICO region. It is used to determine whether a scene is classified as clear or...

  6. Modeling and simulation of gamma camera

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Simulation techniques play a vital role in designing of sophisticated instruments and also for the training of operating and maintenance staff. Gamma camera systems have been used for functional imaging in nuclear medicine. Functional images are derived from the external counting of the gamma emitting radioactive tracer that after introduction in to the body mimics the behavior of native biochemical compound. The position sensitive detector yield the coordinates of the gamma ray interaction with the detector and are used to estimate the point of gamma ray emission within the tracer distribution space. This advanced imaging device is thus dependent on the performance of algorithm for coordinate computing, estimation of point of emission, generation of image and display of the image data. Contemporary systems also have protocols for quality control and clinical evaluation of imaging studies. Simulation of this processing leads to understanding of the basic camera design problems. This report describes a PC based package for design and simulation of gamma camera along with the options of simulating data acquisition and quality control of imaging studies. Image display and data processing the other options implemented in SIMCAM will be described in separate reports (under preparation). Gamma camera modeling and simulation in SIMCAM has preset configuration of the design parameters for various sizes of crystal detector with the option to pack the PMT on hexagon or square lattice. Different algorithm for computation of coordinates and spatial distortion removal are allowed in addition to the simulation of energy correction circuit. The user can simulate different static, dynamic, MUGA and SPECT studies. The acquired/ simulated data is processed for quality control and clinical evaluation of the imaging studies. Results show that the program can be used to assess these performances. Also the variations in performance parameters can be assessed due to the induced

  7. Suppression of superconductivity in Nb by IrMn in IrMn/Nb bilayers

    KAUST Repository

    Wu, B. L.

    2013-10-10

    Effect of antiferromagnet on superconductivity has been investigated in IrMn/Nb bilayers. Significant suppression of both transition temperature (Tc) and lower critical field (Hc1) of Nb is found in IrMn/Nb bilayers as compared to a single layer Nb of same thickness; the suppression effect is even stronger than that of a ferromagnet in NiFe/Nb bilayers. The addition of an insulating MgO layer at the IrMn-Nb interface nearly restores Tc to that of the single layer Nb, but Hc1 still remains suppressed. These results suggest that, in addition to proximity effect and magnetic impurity scattering, magnetostatic interaction also plays a role in suppressing superconductivity of Nb in IrMn/Nb bilayers. In addition to reduced Tc and Hc1, the IrMn layer also induces broadening in the transition temperature of Nb, which can be accounted for by a finite distribution of stray field from IrMn.

  8. Discrimination of Chinese Sauce liquor using FT-IR and two-dimensional correlation IR spectroscopy

    Science.gov (United States)

    Sun, Su-Qin; Li, Chang-Wen; Wei, Ji-Ping; Zhou, Qun; Noda, Isao

    2006-11-01

    We applied the three-step IR macro-fingerprint identification method to obtain the IR characteristic fingerprints of so-called Chinese Sauce liquor (Moutai liquor and Kinsly liquor) and a counterfeit Moutai. These fingerprints can be used for the identification and discrimination of similar liquor products. The comparison of their conventional IR spectra, as the first step of identification, shows that the primary difference in Sauce liquor is the intensity of characteristic peaks at 1592 and 1225 cm -1. The comparison of the second derivative IR spectra, as the second step of identification, shows that the characteristic absorption in 1400-1800 cm -1 is substantially different. The comparison of 2D-IR correlation spectra, as the third and final step of identification, can discriminate the liquors from another direction. Furthermore, the method was successfully applied to the discrimination of a counterfeit Moutai from the genuine Sauce liquor. The success of the three-step IR macro-fingerprint identification to provide a rapid and effective method for the identification of Chinese liquor suggests the potential extension of this technique to the identification and discrimination of other wine and spirits, as well.

  9. Development of pixellated Ir-TESs

    Science.gov (United States)

    Zen, Nobuyuki; Takahashi, Hiroyuki; Kunieda, Yuichi; Damayanthi, Rathnayaka M. T.; Mori, Fumiakira; Fujita, Kaoru; Nakazawa, Masaharu; Fukuda, Daiji; Ohkubo, Masataka

    2006-04-01

    We have been developing Ir-based pixellated superconducting transition edge sensors (TESs). In the area of material or astronomical applications, the sensor with few eV energy resolution and over 1000 pixels imaging property is desired. In order to achieve this goal, we have been analyzing signals from pixellated TESs. In the case of a 20 pixel array of Ir-TESs, with 45 μm×45 μm pixel sizes, the incident X-ray signals have been classified into 16 groups. We have applied numerical signal analysis. On the one hand, the energy resolution of our pixellated TES is strongly degraded. However, using pulse shape analysis, we can dramatically improve the resolution. Thus, we consider that the pulse signal analysis will lead this device to be used as a practical photon incident position identifying TES.

  10. Development of pixellated Ir-TESs

    International Nuclear Information System (INIS)

    Zen, Nobuyuki; Takahashi, Hiroyuki; Kunieda, Yuichi; Dayanthi, Rathnayaka M.T.; Mori, Fumiakira; Fujita, Kaoru; Nakazawa, Masaharu; Fukuda, Daiji; Ohkubo, Masataka

    2006-01-01

    We have been developing Ir-based pixellated superconducting transition edge sensors (TESs). In the area of material or astronomical applications, the sensor with few eV energy resolution and over 1000 pixels imaging property is desired. In order to achieve this goal, we have been analyzing signals from pixellated TESs. In the case of a 20 pixel array of Ir-TESs, with 45 μmx45 μm pixel sizes, the incident X-ray signals have been classified into 16 groups. We have applied numerical signal analysis. On the one hand, the energy resolution of our pixellated TES is strongly degraded. However, using pulse shape analysis, we can dramatically improve the resolution. Thus, we consider that the pulse signal analysis will lead this device to be used as a practical photon incident position identifying TES

  11. Development of Ir/Au-TES microcalorimeter

    International Nuclear Information System (INIS)

    Kunieda, Yuichi; Fukuda, Daiji; Ohno, Masashi; Nakazawa, Masaharu; Takahashi, Hiroyuki; Ataka, Manabu; Ohkubo, Masataka; Hirayama, Fuminori

    2004-01-01

    We are developing X-ray microcalorimeters using transition edge sensors (TES) for high resolution x-ray spectroscopy. Microcalorimeters are thermal detectors which measure the energy of an incident x-ray photon using a TES thermometer operated at a sharp transition edge between normal and superconducting states. TES microcalorimeters can achieve faster response than conventional microcalorimeters by keeping the operating point of TES in the transition region through the use of strong negative electrothermal feedback (ETF). We developed a bilayer TES where a normal metal Au was deposited on a superconductor Ir in order to improve the thermal conductivity of the Ir-TES. We investigated resistance-temperature characteristics. As a result, it showed a very sharp transition within 1 mK at the temperature of 110 mK. The energy resolution of 9.4 eV (FWHM) was achieved for a 5899 eV Mn K al line. (author)

  12. Characterization of Ir/Au pixel TES

    International Nuclear Information System (INIS)

    Kunieda, Y.; Takahashi, H.; Zen, N.; Damayanthi, R.M.T.; Mori, F.; Fujita, K.; Nakazawa, M.; Fukuda, D.; Ohkubo, M.

    2006-01-01

    Signal shapes and noise characteristics of an asymmetrical ten-pixel Ir/Au-TES have been studied. The asymmetric design may be effective to realize an imaging spectrometer. Distinct two exponential decays observed for X-ray events are consistent with a two-step R-T curve. A theoretical thermal model for noise in multi-pixel devices reasonably explains the experimental data

  13. Traveling wave deflector design for femtosecond streak camera

    International Nuclear Information System (INIS)

    Pei, Chengquan; Wu, Shengli; Luo, Duan; Wen, Wenlong; Xu, Junkai; Tian, Jinshou; Zhang, Minrui; Chen, Pin; Chen, Jianzhong; Liu, Rong

    2017-01-01

    In this paper, a traveling wave deflection deflector (TWD) with a slow-wave property induced by a microstrip transmission line is proposed for femtosecond streak cameras. The pass width and dispersion properties were simulated. In addition, the dynamic temporal resolution of the femtosecond camera was simulated by CST software. The results showed that with the proposed TWD a femtosecond streak camera can achieve a dynamic temporal resolution of less than 600 fs. Experiments were done to test the femtosecond streak camera, and an 800 fs dynamic temporal resolution was obtained. Guidance is provided for optimizing a femtosecond streak camera to obtain higher temporal resolution.

  14. Traveling wave deflector design for femtosecond streak camera

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan; Wu, Shengli [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Luo, Duan [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Wen, Wenlong [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Xu, Junkai [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Tian, Jinshou, E-mail: tianjs@opt.ac.cn [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, Shanxi 030006 (China); Zhang, Minrui; Chen, Pin [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Chen, Jianzhong [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Liu, Rong [Xi' an Technological University, Xi' an 710021 (China)

    2017-05-21

    In this paper, a traveling wave deflection deflector (TWD) with a slow-wave property induced by a microstrip transmission line is proposed for femtosecond streak cameras. The pass width and dispersion properties were simulated. In addition, the dynamic temporal resolution of the femtosecond camera was simulated by CST software. The results showed that with the proposed TWD a femtosecond streak camera can achieve a dynamic temporal resolution of less than 600 fs. Experiments were done to test the femtosecond streak camera, and an 800 fs dynamic temporal resolution was obtained. Guidance is provided for optimizing a femtosecond streak camera to obtain higher temporal resolution.

  15. Using a laser scanning camera for reactor inspection

    International Nuclear Information System (INIS)

    Armour, I.A.; Adrain, R.S.; Klewe, R.C.

    1984-01-01

    Inspection of nuclear reactors is normally carried out using TV or film cameras. There are, however, several areas where these cameras show considerable shortcomings. To overcome these difficulties, laser scanning cameras have been developed. This type of camera can be used for general visual inspection as well as the provision of high resolution video images with high ratio on and off-axis zoom capability. In this paper, we outline the construction and operation of a laser scanning camera and give examples of how it has been used in various power stations, and indicate future potential developments. (author)

  16. Long wavelength infrared camera (LWIRC): a 10 micron camera for the Keck Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Wishnow, E.H.; Danchi, W.C.; Tuthill, P.; Wurtz, R.; Jernigan, J.G.; Arens, J.F.

    1998-05-01

    The Long Wavelength Infrared Camera (LWIRC) is a facility instrument for the Keck Observatory designed to operate at the f/25 forward Cassegrain focus of the Keck I telescope. The camera operates over the wavelength band 7-13 {micro}m using ZnSe transmissive optics. A set of filters, a circular variable filter (CVF), and a mid-infrared polarizer are available, as are three plate scales: 0.05``, 0.10``, 0.21`` per pixel. The camera focal plane array and optics are cooled using liquid helium. The system has been refurbished with a 128 x 128 pixel Si:As detector array. The electronics readout system used to clock the array is compatible with both the hardware and software of the other Keck infrared instruments NIRC and LWS. A new pre-amplifier/A-D converter has been designed and constructed which decreases greatly the system susceptibility to noise.

  17. Preliminary field evaluation of solid state cameras for security applications

    International Nuclear Information System (INIS)

    1987-01-01

    Recent developments in solid state imager technology have resulted in a series of compact, lightweight, all-solid-state closed circuit television (CCTV) cameras. Although it is widely known that the various solid state cameras have less light sensitivity and lower resolution than their vacuum tube counterparts, the potential for having a much longer Mean Time Between Failure (MTBF) for the all-solid-state cameras is generating considerable interest within the security community. Questions have been raised as to whether the newest and best of the solid state cameras are a viable alternative to the high maintenance vacuum tube cameras in exterior security applications. To help answer these questions, a series of tests were performed by Sandia National Laboratories at various test sites and under several lighting conditions. In general, all-solid-state cameras need to be improved in four areas before they can be used as wholesale replacements for tube cameras in exterior security applications: resolution, sensitivity, contrast, and smear. However, with careful design some of the higher performance cameras can be used for perimeter security systems, and all of the cameras have applications where they are uniquely qualified. Many of the cameras are well suited for interior assessment and surveillance uses, and several of the cameras are well designed as robotics and machine vision devices

  18. Initial laboratory evaluation of color video cameras: Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Terry, P.L.

    1993-07-01

    Sandia National Laboratories has considerable experience with monochrome video cameras used in alarm assessment video systems. Most of these systems, used for perimeter protection, were designed to classify rather than to identify intruders. The monochrome cameras were selected over color cameras because they have greater sensitivity and resolution. There is a growing interest in the identification function of security video systems for both access control and insider protection. Because color camera technology is rapidly changing and because color information is useful for identification purposes, Sandia National Laboratories has established an on-going program to evaluate the newest color solid-state cameras. Phase One of the Sandia program resulted in the SAND91-2579/1 report titled: Initial Laboratory Evaluation of Color Video Cameras. The report briefly discusses imager chips, color cameras, and monitors, describes the camera selection, details traditional test parameters and procedures, and gives the results reached by evaluating 12 cameras. Here, in Phase Two of the report, we tested 6 additional cameras using traditional methods. In addition, all 18 cameras were tested by newly developed methods. This Phase 2 report details those newly developed test parameters and procedures, and evaluates the results.

  19. Presence capture cameras - a new challenge to the image quality

    Science.gov (United States)

    Peltoketo, Veli-Tapani

    2016-04-01

    Commercial presence capture cameras are coming to the markets and a new era of visual entertainment starts to get its shape. Since the true presence capturing is still a very new technology, the real technical solutions are just passed a prototyping phase and they vary a lot. Presence capture cameras have still the same quality issues to tackle as previous phases of digital imaging but also numerous new ones. This work concentrates to the quality challenges of presence capture cameras. A camera system which can record 3D audio-visual reality as it is has to have several camera modules, several microphones and especially technology which can synchronize output of several sources to a seamless and smooth virtual reality experience. Several traditional quality features are still valid in presence capture cameras. Features like color fidelity, noise removal, resolution and dynamic range create the base of virtual reality stream quality. However, co-operation of several cameras brings a new dimension for these quality factors. Also new quality features can be validated. For example, how the camera streams should be stitched together with 3D experience without noticeable errors and how to validate the stitching? The work describes quality factors which are still valid in the presence capture cameras and defines the importance of those. Moreover, new challenges of presence capture cameras are investigated in image and video quality point of view. The work contains considerations how well current measurement methods can be used in presence capture cameras.

  20. Qualification Tests of Micro-camera Modules for Space Applications

    Science.gov (United States)

    Kimura, Shinichi; Miyasaka, Akira

    Visual capability is very important for space-based activities, for which small, low-cost space cameras are desired. Although cameras for terrestrial applications are continually being improved, little progress has been made on cameras used in space, which must be extremely robust to withstand harsh environments. This study focuses on commercial off-the-shelf (COTS) CMOS digital cameras because they are very small and are based on an established mass-market technology. Radiation and ultrahigh-vacuum tests were conducted on a small COTS camera that weighs less than 100 mg (including optics). This paper presents the results of the qualification tests for COTS cameras and for a small, low-cost COTS-based space camera.